1. Level 1 Level 2 Level 3 Level 4 Value 03 Set chrono 01 enable chrono 01 enable chrono on off 02 day program 01 day chrono on off 02 start 1 day time 03 stop 1 day time 04 start 2 day time 05 stop 2 day time 03 week program 01 week chrono on off 02 start 1 day time 03 stop 1 day time 04 Monday prog 1 on off 05 Tuesday prog 1 on off 06 Wednesday prog 1 on off 07 Thursday prog 1 on off 08 Friday prog 1 on off 09 Saturday prog 1 on off 10 Sunday prog 1 on off 11 start prog 2 time 12 stop prog 2 time 13 Monday prog 2 on off 14 Tuesday prog 2 on off 15 Wednesday prog 2 on off 16 Thursday prog 2 on off 17 Friday prog 2 on off 18 Saturday prog 2 on off 19 Sunday prog 2 on off 20 start prog 3 time 21 stop prog 3 time 22 Monday prog 3 on off 23 Tuesday prog 3 on off 24 Wednesday prog 3 on off 25 Thursday prog 3 on off 26 Friday prog 3 on off 27 Saturday prog 3 on off 28 Sunday prog 3 on off 29 start prog 4 time 30 stop prog 4 time 31 Monday prog 4 on off 32 Tuesday prog 4 on off 33 Wednesday prog 4 on off 34 Thursday prog 4 on off 35 Friday prog 4 on off 36 Saturday pro
2. viter la formation de fum e ou d imbr les pendant l allumage et ou le fonctionnement normal l accumulation excessive de granul s imbr les dans le brasier doit tre retir e manuellement avant tout allumage Informer les enfants et les visiteurs des dangers d crits ci dessus En cas d anomalie de fonctionnement le po le peut tre rallum seulement apr s avoir r tabli la cause de l inconv nient Toute modification ou adaptation non pr vue et ou tout remplacement non autoris de pi ces non originales du po le peut repr senter un danger pour les personnes et d gage le constructeur de toute responsabilit civile et p nale N utiliser que des pi ces de rechange d origine La soci t Cola s r l d cline toute responsabilit pour les inconv nients les ruptures ou les accidents caus s par l inobservation ou l inapplication des indications contenues dans ce manuel 62 EASY CRONO HR COLA 1 4 Description technique Le po le fonctionne exclusivement granul s et propage une chaleur saine et rassurante dans la pi ce Les syst mes de contr le automatiques dont il est pourvu assurent un rendement thermique optimal et une combustion complete Des syst mes de s curit garantissent des conditions de s curit pour l utilisateur et la fiabilit des composants du po le Si le po le est install conform ment aux textes r glementaires et r gles de l art en vigueur il fonctionnera dans n importe quelle
3. 76 EASY CRONO HR COLA Niveau 1 Niveau 2 Niveau 3 Niveau 4 Valeur 04 choix de la langue 01 italien set 02 frangais set 03 anglais set 04 allemand set 05 mode veille stand by on off 06 alarme sonore buzzer on off 07 chargement initial set 08 tat du po le 4 6 1 Menu 01 r glage des ventilateurs La vitesse des ventilateurs air est automatiquement asservie la puissance r gl e Si l on souhaite diminuer le flux d air chaud il est possible de r gler manuellement la vitesse maximum au travers du menu 01 en choisissant une valeur de 1 5 Par exemple En r glant la vitesse 3 les ventilateurs augmenteront automatiquement la vitesse mais sans d passer la vitesse impos e 3 Dans la version canalisable le raccordement lectrique est visualisable avec l activation des deux segments led B 4 6 2 Menu 02 r glage de l horloge Le r gulateur lectronique est quip d une batterie lithium mod CR2032 de 3 Volt qui permet l horloge interne une autonomie sup rieure 4 ou 5 ans si lorsque le po le est arr t l horloge ne maintient pas l horaire ou au rallumage appara t une s rie de z ro il sera n cessaire de proc der son remplacement en appelant le centre d assistance agr 4 6 3 Menu 03 activation du chrono Permet d activer et de d sactiver toutes les fonctions du Cronotermostato
4. AM alarme 72 EASY CRONO HR COLA 4 3 Allumage 4 3 1 Contr le avant l allumage Avant d allumer le po le il faut s assurer d avoir bien lu et compris les indications contenues dans le manuel s assurer que le r servoir granul s est rempli s assurer que le chambre de combustion est propre s assurer que le brasier est totalement libre propre sans d p ts et correctement en place v rifier la fermeture herm tique de la porte de foyer et du cendrier v rifier le branchement du c ble lectrique et la commutation ON 1 de l interrupteur mont l arri re du po le la premi re mise en service enlever du foyer et de la vitre de foyer toutes les choses qui pourraient A br ler instructions tiquette Les allumages ventuels apr s de longues p riodes d inactivit du po le ne doivent s effectuer qu apr s avoir enlev les r sidus de granul s rest s dans le fond du r servoir car ils ne s enflammeraient plus trop humides et un nettoyage complet de la chambre de combustion 4 3 2 Mise en marche Pour allumer le po le appuyer sur le bouton P4 pendant 3 secondes sur l cran appara tra l indication START Cette phase est automatique et est compl tement g r e par l lectronique de commande Il n est pas possible ici d intervenir sur les param tres Horloge Temp rature ambiante l i 1436 eye P Y ALLUNAgE Bouton P4 Fen tre de dialogue Puissan pr
5. mercoled prog 4 on off 34 giovedi prog 4 on off 35 venerdi prog 4 on off 36 sabato prog 4 on off 37 domenica prog 4 on off 04 program week end 01 crono week end on off 02 start 1 03 stop 1 04 start 2 05 stop 2 18 EASY CRONO HR COLA Livello 1 Livello 2 Livello 3 Livello 4 Valore 04 Scegli lingua 01 italiano set 02 francese set 03 inglese set 04 tedesco set 05 Modo stand by on off 06 Cicalino on off 07 Carico iniziale set 08 Stato stufa 4 6 1 Menu 01 regola ventole Le velocit delle ventole dell aria automatica e segue la potenza impostata Se si desidera limitare il flusso d aria calda possibile impostare manualmente la velocit massima tramite la voce del menu 01 scegliendo un valore da 1 a 5 ad esempio impostando il valore 3 i ventilatori aumenteranno automaticamente la velocit ma senza superare la velocit d impostazione pari a 3 Nella versione canalizzabile il collegamento elettrico viene visualizzato con l attivazione dei due segmenti led B 4 6 2 Menu 02 set orologio Prima di operare con la stufa necessario impostare l ora e la data corrente affinch si abbia un riferimento per le possibili programmazioni sul crono Il controllo elettronico provvisto di batteria al litio mod CR2032 da 3 Volt che permette all orologio interno un autonomia superi
6. Avec la selection ON s active la fonction et appara t sur l cran le segment led D Lorsqu une programmation journali re hebdomadaire ou weekend a Se end est ins r e l cran laisse apparaitre respectivement sur OF F la partie sup rieure droite le segment led appropri C n 3 4 I Pour la s lection et la saisie des horaires il faut agir sur six 11 boutons en suivant les indications du tableau 4 2 PE r nE f CHRONO Niveau de menu Aller dans le sous menu PROGRAM JOUR pour activer d sactiver et pr s lectionner les fonctions du chronothermostat journalier Il est possible de r gler deux phases de fonctionnement d limit es par les horaires pr d finis selon le tableau suivant o le r glage OFF indique l horloge d ignorer la commande S lection Signification Valeurs possibles START 1 Heure d activation ora OFF STOP 1 Heure de d sactivation ora OFF START 2 Heure d activati mE g er nl cai Fen tre de dialogue STOP 2 Heure de d sactivation ora OFF 77 EASY CRONO HR Entr e Aller dans le sous menu PROGRAM SEMAINE pour activer d sactiver et pr s lectionner les fonctions du chronothermostat hebdomadaire Le programmateur hebdomadaire dispose de 4 programmes ind pendants qui en final se traduisent par la combinaison des 4 programmations Le programmateur hebdomadaire peut tre activ ou d sactiv et d autre part en mettant OFF da
7. Il fabbisogno energetico dell edificio pu variare in funzione dell isolamento della tipologia e della zona climatica 5 EASY CRONO HR 990 Legenda A Griglie passaggio aria B Allacciamento cavo elettrico C Aspirazione aria comburente diam 50mm D Allacciamento tubo espulsione fumi diam 80mm E Sportello serbatoio pellet 516 COLA 499 0200000000000 0000090090000 nboasaascaasad 000000000000 Ingombri stufa pellet EASY CRONO HR EASY CRONO HR COLA Per aprire la porta inserire la maniglia in dotazione e ruotare Maniglia apertura chiusura in senso orario porta fuoco Apertura senso orario Chiusura senso antiorario 1 5 Combustibile e uso consentito Le stufe a pellet funzionano esclusivamente con pellet pastiglie di varie essenze di legno conformi alla normativa DIN plus 51731 o UNI EN 14961 2 o O Norm M 7135 ovvero aventi le seguenti caratteristiche Potere calorico min 4 8 kWh kg 4180 kcal kg Densit 680 720 kg m3 Umidit max 10 del peso Diametro 6 0 5 mm Percentuale ceneri max 1 5 del peso Lunghezza min 6 mm max 30 mm Composizione 100 legno non trattato dell industria del legno o post consumo senza aggiunta di sostanze leganti e privo di corteccia conforme alle normative vigenti Imballo in sacchi realizzati in materiale ecocompatibile o biologicamente decomponibile o in carta Il serbatoio di co
8. Restart the stove normally 3 5 Safety against flare back in the pellet chute The solutions preventing flare back are gt negative pressure in the combustion chamber see par 3 2 gt the siphon shape of the pellet chute the hopper temperature safety see par 3 4 3 6 Overcurrent protection device The unit is protected against overcurrent by 2A fuses on the power supply of the main stove switch located at the back 41 EASY CRONO HR COLA 3 7 Power failure safety In case of brief power failures the stove relights automatically A temporary power failure does not limit stove safety and the hopper temperature does not reach high values lt 850 given the small quantity of pellets burning in the brazier This anomaly can result in some smoke briefly escaping into the room which does not involve any risk for safety A Do not tamper with the safety devices 3 8 Fume extractor fan failure If the fume extractor fan stops for any reason the electronic controller instantly stops the pellet feed displaying the message AL 4 FAN FAIL 4 STOVE USE 4 1 Introduction The pellet stove has the advantage of combining heat from a wood flame with the convenience of automatic management of temperature and the possibility of weekly programming of lighting and shutdown Connection to an external thermostat and or chronothermostat is possible for detecting the temperature in a different place from where the stove is instal
9. nn from ground the fumes coming from a single unit and where permitted Sl more than than one FLUE technical requirements it must be fumetight isolated and insulated Antiwind 3 depending on its use grille ta it must have a mainly vertical path with axis deviation lt 453 _ Sy it must be at a suitable distance from flammable materials with insulation Flue or air gap it must preferably have a constant free and independent round internal Ao section it is advisable for the flue to have an inspectionable chamber for the ae collection of solid materials chamber and any condensate placed under the beginning of the fume duct Ext air inlet min 100 cm2 FLUE CONNECTION or DUCT duct or connection element between the Mins distance 0am ce P unit and flue for evacuation of fumes DUCT technical requirements it must not cross rooms in which the installation of combustion units is not allowed flexible metal tubes or fibre cement pipes are prohibited 39 EASY CRONO HR COLA the use of counter sloping elements is prohibited horizontal sections must have an upward slope of at least 3 the length of the horizontal section must be minimal and not more than 3 m there must not be more than 3 changes of direction without the T union with change of direction gt 90 a max of 2 bends can be used with length in horizontal projection not exceeding 2 m the fume duct must have a
10. respect to the room temperature Dialogue box Output 45 EASY CRONO HR COLA 14396 During normal operation in work mode the CLEANING FIRE pas g rc P 4 POT mode is activated at fixed intervals for a set duration A f r CLEANI nG FIRE POE 4 5 Shutting down To shut down the stove just press the button P4 for about 2 seconds The auger is stopped immediately and the fume extractor is brought to high speed with the message FINAL CLEANING displayed both fume extraction and air ventilation motors remain on until the stove temperature has lowered sufficiently Dialogue box Output Button P4 At the end of the operation the message OFF appears in the dialogue box During the shutdown stage the stove cannot be restarted until the fume temperature has fallen below a set value for a fixed time with the message WAITING COOL appearing in the dialogue box 4 6 Menu Press the button P3 SET to access the menu this is divided into various items and levels for accessing the settings of the electronic controller The following table summarises the menu structure with the selections available to the user Level 1 Level 2 Level 3 Level 4 Value 01 Adjust fans Select value 02 Set clock 01 day Day 02 hours Hours 03 minutes Minutes 04 day Day 05 month Month 06 year Year 46 EASY CRONO HR COLA
11. 3 Motor ducteur 4 Vis sans fin 5 Joint pour goulotte 6 Goulotte de granul s 7 Joint de chambre convoyeur 8 Convoyeur de granul s 85 EASY CRONO HR COLA 6 4 Composants lectriques 022 0999 os 0950 0990 990259 o 0999 0999 0999 n 0990 9900 n 0960 1 9909909 2230 050999 393909009909 0959 003999 909500 09500 9223009502 099 00950 0990 o 9003 050235 09502 o 9 9 2 30 gt o 00999970950 223 009000500902 235 009909900900 0 00500 202609 960 20 502250 339300053 e ceco o Sooo Seo Seen T Sor lt ve gt DO A DA OSS ISS L gende 1 Carte lectronique 2 Vacuostat de contr le et s curit 3 Thermostat de s curit 4 Interrupteur ON OFF avec fusibles 5 Sonde de temp rature ambiante 6 Sonde de temp rature des fum es 7 D bitm tre 8 Ventilateur tangentiel droit 9 Ventilateur tangentiel gauche 10 Ventilateur tangentiel post rieur 11 Tableau de commande mod F047 12 Motor ducteur 86 EASY CRONO HR 7 RECHERCHE DES PANNES 7 1 Gestion des alarmes COLA Les alarmes sont signal es a la fois visuellement l cran message et par un signal sonore si active En cas d alarme teindre le po le liminer la cause de la panne et remettre en marche le po le en respectant la proc dure normale d crite dans ce manuel Les alarmes visualis
12. 4 Vermiculite side walls 1 5 Vermiculite upper baffle 6 Vermiculite rear wall Exploded view of EASY CRONO HR stove combustion chamber and parts EASY CRONO HR 55 COLA Exploded views of 1 Brazier assembly 2 Fume extractor assembly 3 Auger assembly Key 1 Brazier 2 Brazier holder 3 Combustion air inlet pipe assembly 4 Electrical element 5 Brazier holder rear seal 6 Suction unit front seal Key 1 Fume extractor volute 2 Thermal seal 3 Fume extractor motor 4 Fume exhaust pipe Key 1 Conveyor hopper seal 2 Gearmotor support flange 3 Gearmotor 4 Auger 5 Seal for chute 6 Pellet chute 7 Conveyor chamber seal 8 Pellet conveyor 56 EASY CRONO HR COLA 6 4 Electrical components Key 1 Electronic board 2 Control and safety vacuum switch 3 Safety thermostat 4 ON OFF switch with fuses 5 Room probe 6 Fume probe 7 Air flow meter 8 Right tangential fan 9 Left tangential fan 10 Rear tangential fan 11 Control panel model ECO T 12 Gearmotor 57 EASY CRONO HR 7 TROUBLESHOOTING 7 1 Alarm management COLA Alarms are indicated by an acoustic signal if activated and a message on the control panel In case of an alarm shut down the stove eliminate the cause and restart the stove according to the normal procedure described in this manual The alarms with causes and cur
13. 5 6 Nettoyage du conduit de raccordement conduit de fum e ENTRETIEN 6 1 Introduction 6 2 D pose de l habillage 6 3 Composants internes du po le 6 4 Composants lectriques RECHERCHE DES PANNES 7 1 Gestion des alarmes ANNEXES 8 1 Informations relatives au marquage CE EASY CRONO HR COLA 1 RECOMMANDATIONS G N RALES 1 1 Introduction Cher Client Nous vous remercions de la confiance que vous nous avez accord e en achetant ce produit Nous vous invitons lire et a suivre attentivement les conseils fournis par ce manuel d installation d utilisation et d entretien pour exploiter au mieux les qualit s de cet appareil 1 2 Comment utiliser ce manuel La soci t COLA s r l se r serve d apporter des modifications techniques ou esth tiques a ses produits n importe quel moment et sans pr avis Les op rations d installation d utilisation et d entretien du po le doivent satisfaire les exigences de ce manuel des normes europ ennes nationales et locales Toutes les configurations les dessins les mesures et les sch mas sont fournis titre d exemple Ce manuel constitue une partie int grante et essentielle du produit si l appareil doit tre vendu ou transf r un autre propri taire ou s il doit tre install un autre endroit s assurer que le manuel accompagne l appareil afin qu il puisse tre consult ult rieurement tout moment En cas de perte ou de d t rioration de ce manuel demand
14. 6 Raumtemperaturf hler 7 Abgasf hler 8 Rechter Tangentialventilator 9 Linker Tangentialventilator 10 Hinterer Tangentialventilator 11 Bedienpanel Mod ECO T 12 Getriebemotor 116 EASY CRONO HR 7 FEHLERSUCHE 7 1 Verwaltung der Alarmmeldungen COLA Ein Alarm wird durch ein akustisches Signal sofern aktiviert und eine Meldung am Bedienpanel angezeigt Bei Auftreten eines Alarms den Ofen abschalten Alarmursache beheben und erst dann den Ofen wie im vorliegenden Handbuch beschrieben wieder einschalten Nachstehend sind die eventuell am Bedienpanel angezeigten Alarme mit Ursache und Abhilfe aufgef hrt ALARME MELDUNGEN Anzeige Betriebsst rung M gliche Ursachen Abhilfen Den Ofen durch Dr cken der Taste P4 auf OFF stellen und den Einschaltvorgang wiederholen AL 1 Keine Stromversorgung w hrend Andere Vorg nge zur STROMAUSFALL BEP Ofen schaltet nichten des Z ndvorgangs Wiederherstellung des Ofenbetriebs m ssen von einer autorisierten Kundendienststelle durchgef hrt werden Wird ausgel st bei Defekt des R n Die Vorgange zur Wiederherstellung AL 2 Abgastemperaturf hlers _ sa Li 3 an der Platine des Ofenbetriebs m ssen von einer ABGASFUHLER Der Abschaltvorgang wird dhdeschlossen autorisierten Kundendienststelle aktiviert 9 durchgef hrt werden Wird ausgel st wenn der _ i f Pelletzuf hrung einstellen Abgastemperaturf hler eine o mn
15. Montag Prog 2 on off 14 Dienstag Prog 2 on off 15 Mittwoch Prog 2 on off 16 Donnerstag Prog 2 on off 17 Freitag Prog 2 on off 18 Samstag Prog 2 on off 19 Sonntag Prog 2 on off 20 Start Prog 3 Uhrzeit 21 Stop Prog 3 Uhrzeit 22 Montag Prog 3 on off 23 Dienstag Prog 3 on off 24 Mittwoch Prog 3 on off 25 Donnerstag Prog 3 on off 26 Freitag Prog 3 on off 27 Samstag Prog 3 on off 28 Sonntag Prog 3 on off 29 Start Prog 4 Uhrzeit 30 Stop Prog 4 Uhrzeit 31 Montag Prog 4 on off 32 Dienstag Prog 4 on off 33 Mittwoch Prog 4 on off 34 Donnerstag Prog 4 on off 35 Freitag Prog 4 on off 36 Samstag Prog 4 on off 37 Sonntag Prog 4 on off 04 Program Wochenende 01 Uhrenthermostat Wochenende on off 02 Start 1 03 Stop 1 04 Start 2 05 Stop 2 Ebene 1 Ebene 2 Ebene 3 Ebene 4 Wert 04 Sprache w hlen 01 Italienisch Set 02 Franz sisch Set 03 Englisch Set 04 Deutsch Set 05 Standbybetrieb on off 06 Summer on off 07 Erste Pelletf llung Set 08 Betriebszustand 7 des Ofens 106 EASY CRONO HR 4 6 1 Men 01 L fter regeln COLA Die Drehzahl der L fterr der ist automatisch und h ngt von der eingestellten Leistung ab Wenn der Zustrom von Warmluft eingeschr nkt werden soll kann die max Drehzahl mit der Option von Men 01 von Hand auf einen Wert zwisch
16. STUNDEN g Wartung m ssen vom Vertragskundendienst 1800 Stunden in Betrieb war durchgef hrt werden Der Hersteller beh lt sich jederzeitige nderungen hinsichtlich technischer Ausf hrung oder Design ohne Vorank ndigung vor Alle Abbildungen Ma e Ubersichtszeichnungen sowie s mtliche sonstigen Angaben in dieser Druckschrift dienen nur zur Veranschaulichung und sind nicht verbindlich 118 EASY CRONO HR 8 ANLAGEN Informationen zur CE Kennzeichnung COLA CE COLA 2012 EN 14785 2006 Pellet fen f r den Heimbetrieb Raumheizer zur Verfeuerung von Holzpellets Nr EASY CRONO HR Mindestsicherheitsabstand von entflammbaren Materialien 200 300 0 mm CO Emission bei 13 O2 in den Verbrennungsprodukten Pnom 0 01 Prid 0 02 Staubemission bei 13 O2 in den Verbrennungsprodukten Pnom 6 1 mg m Max Betriebswasserdruck bar Abgastemperatur P nom 182 2 dia Pred 80 2 C Nennw rmeleistung und reduzierte P nom 9 29 kW Leistung Pred 2 58 kW P nom 89 26 Wirkungsgrad Pred 95 66 Brennstoffarten Holzpellets Stromleistung 420 W max 120 w Nennspannung 230 V Nennfrequenz 50 Hz 119 EASY CRONO HR
17. The modifications made are anemorised external contact chrono The Figure opposite describes the meaning of the status indicators in the left Am igniter part of the display 2 auger Activation of one of the segments on the display signals activation of the corresponding device according to the list opposite 27 exchanger BA not used alarm 43 EASY CRONO HR COLA 4 3 Lighting 4 3 1 Check before lighting Before lighting the stove make sure you have read and understood that given in the manual the hopper must be filled with pellets the combustion chamber must be clean the brazier must be completely free cleaned of any combustion residuals and correctly fitted in the brazier holder check hermetic closing of the fire door and ash pan check the connection of the power cable and switching to ON 1 of the switch located on the back of the stove and glass Any lightings done after long stove idle periods require the renewal of any pellets that have been inside the hopper for a long time in being a damp fuel no longer suitable for combustion and complete cleaning of the combustion chamber At first startup remove all the components instructions label that could burn from the stove firebox 4 3 2 Startup stage To light the stove press the button P4 for 3 seconds the message START will appear on the display The stage is automatic and managed entirely by the electronic controll
18. anno Anno 17 EASY CRONO HR COLA Livello 1 Livello 2 Livello 3 Livello 4 Valore 03 Set crono 01 abilita crono 01 abilita crono on off 02 program giorno 01 crono giorno on off 02 start 1 giorno ora 03 stop 1 giorno ora 04 start 2 giorno ora 05 stop 2 giorno ora 03 program settim 01 crono settim on off 02 start 1 giorno ora 03 stop 1 giorno ora 04 luned prog 1 on off 05 marted prog 1 on off 06 mercoled prog 1 on off 07 giovedi prog 1 on off 08 venerdi prog 1 on off 09 sabato prog 1 on off 10 domenica prog 1 on off 11 start prog 2 ora 12 stop prog 2 ora 13 lunedi prog 2 on off 14 martedi prog 2 on off 15 mercoled prog 2 on off 16 giovedi prog 2 on off 17 venerdi prog 2 on off 18 sabato prog 2 on off 19 domenica prog 2 on off 20 start prog 3 ora 21 stop prog 3 ora 22 lunedi prog 3 on off 23 martedi prog 3 on off 24 mercoled prog 3 on off 25 giovedi prog 3 on off 26 venerdi prog 3 on off 27 sabato prog 3 on off 28 domenica prog 3 on off 29 start prog 4 ora 30 stop prog 4 ora 31 lunedi prog 4 on off 32 martedi prog 4 on off 33
19. rear right left side floor 200 300 0 mm Nom Output 0 01 issi 13 O2 in fi CO emissions at 13 O2 in fumes Red output 0 02 Dust emissions at 13 O2 in fumes Nom output 6 1 mg m Max water operating pressure bar Nom output 182 2 Flue gas temperature Red output 80 2 Nom output 9 29 kW Nominal and reduced heat output Red output 2 58 kW Nom output 89 26 EISEN Red output 95 66 Types of fuel Wood pellets 420 W max 120w Electrical power Rated voltage 230 V Rated frequency 50Hz 60 EASY CRONO HR 1 RECOMMANDATIONS G N RALES 1 1 Introduction 1 2 Comment utiliser ce manuel 1 3 R gles de s curit 1 4 Description technique 1 5 Combustible et usage pr vu 1 6 Accessoires fournis 1 7 Normes de r f rence 1 8 Plaque d identification 1 9 Mise hors service du po le 1 10 Demande d intervention et de pi ces d tach es TRANSPORT ET INSTALLATION 2 1 Emballage manutention exp dition et transport 2 2 Lieu d installation mise en place et s curit anti incendie 2 3 Prise d air 2 4 Evacuation des fum es de combustion 2 4 1 Types d installations 2 5 Contr le de la position du brasier et du d flecteur 2 6 Branchement lectrique 2 7 Sch ma lectrique 2 8 Premi re intervention S CURIT 3 1 Distance de s curit par rapport aux mat riaux combustibles 3 2 S curit p
20. tres techniques du menu 09 doit tre effectu e par un professionnel agr et A le po le et d gage la soci t COLA de toute responsabilit 79 EASY CRONO HR COLA 4 7 T l commande sur demande La t l commande fonctionne avec les pr s lections ou pr r glages du tableau de commande et permet l allumage et l extinction du po le ainsi que la r gulation de la puissance et de la temp rature d sir e La t l commande transmet par une diode infrarouge et doit donc tre dirig e vers le r cepteur situ sur le tableau de commande du po le La t l commande permet d effectuer les op rations suivantes X A f i Mm jj D L LED allum e apr s l appui d une touche a A quelconque x Touche P1 P6 Allumage extinction du po le 3 hE InN K Touche P1 Augmentation de la temp rature ambiante Touche P6 Augmentation du niveau de puissance a 17 Touche P5 Diminution du niveau de puissance En N TZ me Touche P2 Diminution de la temp rature ambiante 4 7 1 Remplacement de la pile La t l commande fonctionne avec une pile non fournie log e dans le compartiment pile situ dans la partie inf rieure de la t l commande Pour la mise en place de la pile et son remplacement ventuel proc der comme suit Ouvrir le couvercle l arri re de la t l commande Remplacer la pile P23GA de 12 V en respectant la polarit Refermer le
21. 00959950 8002 90939999097 09502900 9 o o Legenda 1 Scheda elettronica 2 Vacuostato di controllo e sicurezza 3 Termostato sicurezza 4 Interruttore ON OFF con fusibili 5 Sonda ambiente 6 Sonda fumi 7 Debimetro 8 Ventilatore tangenziale dx 9 Ventilatore tangenziale sx 10 Ventilatore tangenziale posteriore 11 Pannello di comando mod ECO T 12 Motoriduttore 28 EASY CRONO HR 7 RICERCAGUASTI 7 1 Gestione degli allarmi COLA La presenza di un allarme si identifica con l emissione di un segnale acustico se attivato e con un messaggio presente sul pannello di controllo In caso di allarme spegnere la stufa risolvere la causa che lo ha provocato e riavviare la stufa secondo la normale procedura illustrata nel presente manuale Sotto sono elencati gli allarmi che possono comparire sul pannello di controllo con cause e rimedi ALLARMI MESSAGGI Segnalazione Anomalia Cause possibili Rimedi Portare la stufa in OFF premendo il pulsante P4 e AL 1 Manca l alimentazione ripetere la procedura di BLACK OUT La stufa non si avvia elettrica durante la fase di accensione accensione Altre operazioni di ripristino devono essere condotte da un centro di assistenza Avviene nel caso di guasto AL 2 della sonda di rilevamento La sonda guasta Le operazioni di ripristino SONDA della temperatura dei fumi La sonda scollegata dalla devono essere condotto da un FUMI Vi
22. BRACIERE per una durata prefissata PULI ci A BRAT ERE Finestra di dialogo y 4 5 Spegnimento Per spegnere la stufa sufficiente premere sul pulsante P4 per circa 2 secondi La coclea immediatamente arrestata e l estrattore fumi viene portato a velocit elevata facendo apparire sul display la scritta PULIZIA FINALE entrambi i motori di aspirazione fumi e di ventilazione dell aria resteranno accesi fino a che la temperatura della stufa sar scesa sufficientemente Temperatura ambiente Finestra di dialogo Pulsante P4 Al termine dell operazione comparir sul display nella finestra di dialogo la scritta SPENTO Durante la fase di spegnimento non possibile riavviare la stufa fino a che la temperatura fumi non scesa al di sotto di un valore prefissato per un tempo prestabilito visualizzando sulla finestra di dialogo la scritta ATTESA RAFFRED 4 6 Menu Premendo il tasto P3 SET si accede al menu questo suddiviso in varie voci e livelli che permettono di accedere alle impostazioni del controllo elettronico Il prospetto seguente sintetizza la struttura del menu con le sole selezioni disponibili per l utente Livello 1 Livello 2 Livello 3 Livello 4 Valore 01 Regola ventole Seleziona valore 02 Set orologio 01 giorno Giorno 02 ore Ore 03 minuti Minuti 04 giorno Giorno 05 mese Mese 06
23. Heat value min 4 8 kWh kg 4180 kcal kg Density 680 720 kg m3 Moisture max 10 weight Diameter 6 0 5 mm Ash percentage max 1 5 weight Length min 6 mm max 30 mm Composition 100 untreated wood from the wood industry or post consumer without added binding substances or bark complying with current regulations Packing in bags made from environmentally friendly or biodegradable material or paper The pellet hopper is at the back of the stove The door is located in the top part and pellet loading occurs manually only with the stove off making sure not to overfill The use of pellets with characteristics different from those tested by the technician during first lighting involves a new setting of the stove pellet loading parameters this operation is not covered by the warranty Store the pellets in a dry place For reasons of regular and efficient operation pellets or other fuels cannot be manually loaded A in the brazier Do not load non conforming fuels in the hopper Do not load foreign bodies such as containers boxes bags metals etc in the hopper The use of poor quality and non conforming pellets damages and compromises stove operation invalidating the warranty with the exclusion of liability of the manufacturer 1 6 Accessories supplied The supply includes Electrical power cable Installation use and maintenance manual Fire door opening closing key 36 EASY CRONO HR COLA 1 7 Reference st
24. Le po le est fourni avec une sonde d ambiance fix e par un collier sur la paroi arri re du po le Nous conseillons son d placement afin d am liorer lecture de la temp rature ambiante La longueur du cable de la sonde permet de la d placer et de la positionner plus haut Pour optimiser la lecture de la temp rature ambiante nous conseillons l installation d un thermostat ou appareil d ambiance cf paragraphe 4 8 Il est interdit d installer le po le dans les chambres coucher les salles de bain et d une mani re g n rale dans des locaux o est d j install un autre appareil de chauffage sans une amen e d air A ind pendante En cas d installation du po le sur un parquet moquette ou linol um pr voir une plaque de sol conform ment aux prescriptions du DTU en vigueur l est toujours conseill d installer des quipements anti incendie appropri s Il est interdit d installer le po le dans des ambiances explosives 2 3 Prise d air Le raccordement d aspiration ou la prise d air du po le se trouve l arri re de celui ci et a une section circulaire de 50 mm de diam tre La quantit d air qui doit affluer dans le local d installation du po le doit tre au moins gale au d bit d air n cessaire la combustion par cons quent l air de combustion n cessaire garantir le fonctionnement r gulier de l appareil doit tre pr lev dans la pi ce ou le local condition qu il y ait une p
25. N Keep the remote control away from heat sources and water way respecting the local regulations 4 8 Thermostat external chronothermostat The unit controls the room temperature by means of its own digital thermostat whose function is to detect the temperature through a probe and lower the heat output when the set temperature is reached To use an external thermostat contact an authorised technician and proceed as follows turn off the power by means of the main switch on the back and detach the power cable remove the side panel to access the electronic controller referring to the wiring diagram connect the two wires of thermostat to the respective board TERM terminals refit everything and check correct operation The setting procedure is as follows external thermostat SET the temperature to 70 external chronothermostat SET the temperature to 7C and disable the chrono functions from the menu 03 01 All the menu functions do not change for each of the settings and signalling of the connection occurs with lighting up of the segment LED on the status bar of the display 51 EASY CRONO HR COLA 4 9 Idle period end of season If the stove is not used for long periods and or at the end of each season it is advisable to proceed as follows remove all the pellets from the hopper disconnect the power and remove the power cable clean thoroughly and if necessary have any damaged parts repl
26. cher des Brenntopfes die f r die Verbrennung erforderliche Luft dringen muss Der Brenntopf muss b ndig und luftdicht auf dem Brenntopfhalter aufliegen und zwar auf der gesamten Umrandung Brenntopf verschmutzt Brenntopf sauber Brenntopfhalter sauber 111 EASY CRONO HR COLA 5 2 Reinigung des Aschenbehalters Direkt unter dem Brenntopf dem Brenntopfhalter befindet sich ein herausnehmbarer Aschebeh lter Per procedere alla sua pulizia necessario aprire la porta fuoco ed aspirare con un idoneo aspiratore la cenere presente al suo interno ed eventuali residui di combustione Nach der Reinigung muss die T r geschlossen werden Die Reinigung des Aschebeh lters muss je nach Ofengebrauch alle 2 3 Tage durchgef hrt werden 5 3 Reinigung des Glases und der Luftschlitze Das Glas kann mit einem feuchten Tuch und einem Spezialreiniger ohne Scheuermittel gereinigt werden Zwischen Glas Glashalter und Feuerraumt r am unteren und oberen Teil sind Schlitze f r die Luftzirkulation und die Innenreinigung der Glasscheibe angebracht Diese Schlitze unbedingt von Aschen und Staubresten freihalten Den gesamten inneren Glasrand daher regelm ig reinigen 5 4 Reinigung des Saugzuggebl ses und der Brennkammer Mindestens einmal j hrlich muss die Brennkammer gereinigt und alle Verbrennungsr ckst nde von den inneren Abweisern und von der Abgasf hrung entfernt werden Hierf r die Abdeckung und die obere Frontblende des Ofens en
27. constant section and allow the recovery of soot CHIMNEY CAP a device placed on the top of the flue to facilitate the dispersion of fumes into the atmosphere CHIMNEY CAP technical requirements it must have a section equivalent to that of the flue it must have a useful section not less than double the internal section of the flue it must prevent the entry of rain and foreign bodies and ensure the discharge of fumes in any atmospheric condition it must ensure an adequate dilution of fumes and be positioned outside the backflow area it must be without mechanical means of suction A The direct discharge of fumes must take place on the roof and not towards closed spaces even open air 2 5 Brazier and baffle position check Before lighting the stove make sure the brazier is in the correct position i e fitted in the special slots Also make sure the top smoke baffle is properly fitted A wrongly positioned baffle can result in malfunctioning and excessive blackening of the glass A At every stove lighting check the correct position of the brazier on the brazier holder 2 6 Electrical connection Connect one end of the power cable to the rear socket of the stove and the other to the wall socket The voltage supplied by the system must match that specified on the stove dataplate and in the technical data section of this manual During stove idle periods it is advisable to remove the power cable in accordance with th
28. couvercle de la t l commande Contr ler le fonctionnement r gulier de la t l commande N Tenir la t l commande l cart de toute source de chaleur directe et de l eau La pile de la t l commande doit tre remplac e et limin e conform ment la r glementation en vigueur en mati re de collecte et de traitement des d chets 4 8 Thermostat chronothermostat externe L appareil de serie contr le la temperature ambiante au moyen d un thermostat num rique dont la fonction est de mesurer la temp rature travers une sonde et de diminuer la puissance lorsque la consigne temp rature est atteinte Pour utiliser un thermostat externe faire appel un technicien agr et suivre les instructions suivantes teindre l appareil en agissant sur l interrupteur g n ral plac l arri re du po le et d brancher le cordon d alimentation d monter les panneaux lat raux les flancs pour acc der l lectronique embarqu e d brancher de la carte lectronique les deux fils du thermostat de leurs bornes respectives TERM remonter le tout et v rifier le fonctionnement correct de l appareil Voici la proc dure de pr s lection suivre thermostat externe pr s lectionner une CONSIGNE SET temp rature de7 chronothermostat externe pr s lectionner une CONSIGNE SET temp rature de 7 et d sactiver dans le menu 03 01 les fonctionnalit s chrono Pour chaque pr s
29. den Angaben der folgenden Tabelle entsprechen A 300 mm B 200 mm C 1500 mm D 200 mm 96 EASY CRONO HR COLA Bei der Installation muss gen gend Freiraum gelassen werden damit das Ger t f r die regelm ig anfallenden Wartungseingriffe problemlos zug nglich ist Der Ofen wird mit 4 verstellbaren F en geliefert um die Aufstellung auf nicht perfekt ebenen Fu b den zu erleichtern Um die H he eines Stellfu es zu verstellen den Ofen etwas neigen und den betreffenden Stellfu drehen Bei Lieferung des Ofens ist der Raumtemperaturf hler mit einer Schelle an der Ofenr ckseite angebracht es wird empfohlen die Schelle zu entfernen und den F hler in der idealen Position anzubringen in der die bestm gliche Temperaturmessung entsprechend der Umgebung und der Kabell nge gew hrleistet wird F r eine Temperaturmessung fern vom Ofen wird die Installation eines Raumthermostats Uhrenthermostats empfohlen siehe Abschn 4 8 In Schlafzimmern in Badezimmern und im Allgemeinen in R umen in denen bereits ein anderes Heizger t aufgestellt ist ist die Installation des Ofens ohne eine unabh ngige Luftzufuhr nicht zul ssig Auf Holzfu b den muss das Ger t auf einem vorschriftsm igen Fu bodenschutz aufgestellt werden Auf jeden Fall sind geeignete Brandbek mpfungsmittel bereit zu stellen Die Installation des Ofens in R ume mit explosiver Atmosph re ist nicht zul ssig 2 3 Lufteinlass
30. fectueux r tablissement du fonctionnement normal doivent tre effectu es par un centre d assistance ALb Cette alarme se d clenche lorsque le l lectronique de commande rel ve op rations de r tablissement du motor ducteur fonctionne en continu que le relais de commande du f a ERREUR ppt fonctionnement normal doivent tre et pendant plus de 60 s motor ducteur est d faillant sHectiidas par un contre dassisiance TRIAC COC Le syst me est arr t contacts coll s p i ATTEN Cette alarme se d clenche en Tentative de d blocage en phase ai i REFR er rallumant le po amp le imm diatement d extinction avec le po le chaud en a a apr s l avoir amp teint phase de refroidissement p q p L lectronique de commande ne ws Ag fie pls Z rel ve bas la Guanite disit Les op rations de r tablissement du DEBIMET Cette alarme se d clenche lorsque le pas ag fonctionnement normal doivent tre D FAILLANT d bitm tre est d branch comburant mais n teint pas le po le elle exclut uniquement les fonctions du d bitm tre effectu es par un centre d assistance CH ANCE ENTRETIEN Cette alarme se d clenche lorsque le po le a fonctionn plus de 1800 heures apr s la derni re intervention d entretien Avis d entretien extraordinaire Les op rations de nettoyage entretien extraordinaire et de r tablissement du fonctionnement normal doivent tre effectu es par un cent
31. flammable materials 3 2 Fume exhaust safety 3 3 Combustion chamber overpressure safety 3 4 Overheating pellet hopper temperature safety thermostat 3 5 Safety against flare back in the pellet chute 3 6 Overcurrent electrical protection device 3 7 Power failure safety 3 8 Fume fan failure ENCLOSURES 8 1 CE marking information 4 STOVE USE 4 1 Introduction 4 2 Description of control panel 4 3 Lighting 4 3 1 Check before lighting 4 3 2 Startup stage 4 4 Work stage 4 5 Shutting down the stove 4 6 Menu 4 6 1 menu 01 adjust fans 4 6 2 menu 02 set clock 4 6 3 menu 03 enable chrono 4 6 4 menu 04 select language 4 6 5 menu 05 standby mode 4 6 6 menu 06 buzzer 4 6 7 menu 07 initial loading 4 6 8 menu 08 stove status 4 6 9 menu 09 settings by technician 32 EASY CRONO HR COLA 1 GENERAL INFORMATION 1 1 Introduction Dear Customer First of all we wish to thank you for the trust placed in us by purchasing one of our products Please read and carefully follow the advice given in this installation use and maintenance manual in order make best use of the product 1 2 Using the manual The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice Stove installation use and maintenance operations must comply with the requirements given in this manual as well as the European National Regional Provincial and Municipal regulations The drawin
32. inflammables pour allumer le po le ou raviver la flamme l embrasement des granul s se fait automatiquement lorsque le po le est allum Le po le doit amp tre aliment exclusivement par des granul s dont les caract ristiques sont d crites dans ce manuel Le po le granul s ne doit pas tre utilis comme incin rateur Ne jamais obstruer les bouches d entr e de l air comburant et de sortie des fum es Il est absolument interdit de manipuler des substances facilement inflammables ou explosives proximit du po le pendant son fonctionnement Ne pas d poser ou modifier la grille de protection du r servoir granul s et d une mani re g n rale les dispositifs de s curit Eviter le fonctionnement du po le avec la porte du foyer ouverte et ou la vitre en mauvais tat ou bris e Pendant le fonctionnement la chaleur d gag e par la combustion des granul s surchauffe les surfaces ext rieures du po le telles que la porte du foyer la poign e et le tuyau d vacuation des fum es Eviter donc d entrer en contact avec ces parties sans porter des protections ad quates Toujours tenir a une distance de s curit suffisante tous les objets sensibles la chaleur et ou inflammables Nettoyer r guli rement le foyer chaque allumage ou chargement de granul s Faire nettoyer r guli rement le conduit et les d flecteurs de fum e l int rieur de la chambre de combustion par un technicien qualifi
33. kann Die Anomalie wird mit der Meldung AL 7 THERMOSICHERUNG am Bedienpanel angezeigt Bei Ansprechen des Thermostats folgenderma en vorgehen Den Ofen mindestens 45 Minuten abk hlen lassen Nach Aufschrauben der Sicherheitsabdeckung den Thermostat durch Dr cken der Taste neben dem Schalter an der Ofenr ckseite zur cksetzen siehe nebenstehende Abbildung Den Ofen dann ganz normal wieder einschalten 3 5 Flammenruckschlagschutz im Pelletzuf hrungskanal Das R ckschlagen der Flammen wird verhindert durch gt Unterdruck in der Verbrennungskammer siehe Absatz 3 2 gt Siphonform des Pelletzuf hrungskanals gt Uberhitzungsschutz des Pelletbeh lters siehe Absatz 3 4 3 6 berstrom Schutzvorrichtung Der Ofen ist durch 2A Sicherung en an der Zuleitung des hinten angebrachten Hauptschalters gegen Uberstrom gesch tzt 3 7 Schutz bei Stromausfall Bei kurzen Unterbrechungen der Stromversorgung wird das Ger t automatisch wieder eingeschaltet Ein vor bergehender Stromausfall beeintr chtigt den Sicherheitsstandard des Ofens nicht und die Beh ltertemperatur kann aufgrund der begrenzten Pelletmenge im Brenntopf nicht zu hoch werden lt 85 W hrend des Stromausfalls kann f r kurze Zeit Rauch in den Raum austreten was jedoch ungef hrlich ist A An den Sicherheitseinrichtungen d rfen keine Eingriffe vorgenommen werden 3 8 Abgasventilator defekt Wenn aus irgendeinem Grund der Abgasventilator stehen blei
34. liquides inflammables pour l allumage du po le En cas d allumages manqu s r p t s faire appel au SAV 4 4 Fonctionnement Apr s la phase de d marrage r ussie le po le passe en mode FONCTIONNEMENT qui repr sente le r gime normal L utilisateur peut alors r gler la puissance de chauffe par les boutons P6 et P5 de la valeur max 5 la valeur min 1 Temp rature ambiante Bouton P6 Bouton P5 s 9 Puissance pr r gl e 4 En plus de la r gulation de la puissance il est possible aussi de r gler la temp rature ambiante directement sur le tableau de commande par les boutons P1 et P sur l cran appara t alors l tat courant de la CONSIGNE SET de temp rature Pour la ventilation de l air chaud le po le r gule automatiquement la vitesse en fonction de la puissance pr r gl e Valeur pr r gl e de la temp rature ambiante CES AFFI CHE EEGP Anib Fen tre de dialogue Il est recommand de contr ler le niveau des granul s dans la tr mie afin d viter que la flamme ne A s teigne pour cause de manque de granul s S assurer que l appareil est teint pour effectuer le chargement des granul s Le couvercle de la tr mie r servoir granul s doit toujours rester ferm Il ne dot tre ouvert que pour effectuer le chargement des granul s Les sacs de granul s doivent tre stock s a une distance d au moins 1 5 m du po le Temp rature
35. muss Wenn die Temperatur 3 g pe fm U hingegen 280C bersteigt erscheint die Alarmmeldung ALARM HOT ABGASE und der Ofen aktiviert den Abschaltvorgang 2 NRK Bei Aktivierung der Betriebsart STANDBY wird der Ofen nach einer bestimmten Nachlaufzeit ausgeschaltet nachdem er den ill AE Temperatur Sollwert erreicht hat Sobald die Raumtemperatur unter einen vorgegebenen Wert sinkt wird der Ofen wieder eingeschaltet W hrend des normalen Betriebs wird in bestimmten vorgegebenen Zeitabst nden die Betriebsart BRENNTOPFREINIGUNG aktiviert deren Dauer ebenfalls vorgegeben ist 104 EASY CRONO HR COLA 4 5 Ausschalten Zum Ausschalten des Ofens einfach die Taste P4 etwa 2 Sekunden lang dr cken Die F rderschnecke wird sofort angehalten das Saugzuggebl se schaltet auf eine hohe Drehzahl und auf dem Display erscheint die Meldung ENDREINIGUNG beide Motoren d h des Saugzug und des Hei luftgebl ses bleiben eingeschaltet bis die Ofentemperatur ausreichend gesunken ist Taste P4 Am Ende des Vorgangs erscheint im Dialogfenster auf dem Display die Meldung OFF W hrend der Abschaltphase kann der Ofen nicht wieder eingeschaltet werden bevor die Abgastemperatur f r eine vorgegebene Dauer unter einen ebenfalls vorgegebenen Wert gesunken ist Im Dialogfenster erscheint die Meldung ABKUHLEN BITTE WARTEN 4 6 Men Durch Dr cken der Taste P3 SET ffnet sich da
36. p n tration de la pluie de la neige et ou d autres corps trangers dans le conduit de fum e et garantir en toutes conditions climatiques l vacuation des produits de combustions les fum es elle doit pouvoir assurer une dilution ad quate des produits et tre positionn e en dehors de la zone de reflux elle ne doit pas comporter de moyens m caniques d aspiration L vacuation directe des produits de combustion doit tre pr vue en toiture et reste interdite vers des espaces clos m me si ciel ouvert 2 5 Contr le de la position du brasier et du deflecteur Avant d allumer le po le contr ler que le brasier soit correctement encastr sur son support Contr ler galement que le d flecteur de fum es sup rieur soit encastr dans son logement Une position incorrecte du d flecteur entra ne des anomalies de fonctionnement et un noircissement excessif de la vitre A Lors de chaque allumage de l appareil contr ler la position correcte du brasier sur son support 2 6 Branchement lectrique Brancher le c ble d alimentation lectrique d une part la prise arri re du po le et d autre part une prise lectrique murale La tension de l installation doit correspondre celle indiqu e sur la plaque d identification du po le et dans le paragraphe des donn es techniques de ce manuel Pendant la p riode d inutilisation du po le il est pr f rable de d brancher son c ble d alimentation l interrupte
37. parcours de fum es Pour cela enlever le couvercle et la fa ade sup rieur du po le D poser l changeur en fonte en desserrant les vis de fixation puis proc der au nettoyage des chicanes et de la chambre de combustion Il est d autre part important de nettoyer l extracteur de fum es qui se trouve sous la chambre et qui est accessible en enlevant l orifice d ispection situ sur la partie avant inferiure de la chambre Tous les 3 4 mois nettoyer les parois internes de la chambre de combustion avec des outils pinceaux appropri s et remplacer ventuellement le matelas de vermiculite car consid r comme un consommable Le po le signale toutes les 1800 heures de fonctionnement travers un message ECHEANCE ENTRETIEN la n cessit d effectuer un entretien extraordinaire qui n est pas couvert par la garantie par un professionnel qualifi qui proc dera un nettoyage complet et la r initialisation du message A Tous chocs ou for ages ventuels peuvent endommager l extracteur des fum es et rendre son fonctionnement bruyant Par cons quent faire effectuer cette op ration par un professionnel qualifi 5 5 Nettoyage du d bitm tre l int rieur du tuyau d aspiration est install un d bitm tre mesureur du d bit d air comburant qui n cessite tous les 3 4 mois d un nettoyage des parois internes l aide d un outillage appropri jet d air comprim ou pinceaux appropri s 5 6 Nettoyage des c ram
38. parti senza opportune protezioni Tenere ad opportuna distanza di sicurezza oggetti non resistenti al calore e o infiammabili Pulire regolarmente il braciere ad ogni accensione o ricarica pellet Pulire regolarmente il condotto e deflettori fumi interno della camera di combustione da personale qualificato Evitare la formazione di fumo ed incombusti in fase di accensione e o durante il normale funzionamento l eccessivo accumulo di pellet incombusto nel braciere deve essere rimosso manualmente prima di procedere con una nuova accensione Avwvertire bambini e ospiti dei pericoli sopra descritti In caso di anomalie di funzionamento la stufa pu essere riaccesa solo dopo avere ripristinato la causa del problema Qualsiasi manomissione e o sostituzione non autorizzata di particolari non originali della stufa pu causare pericolo per l incolumit dell utente e solleva il costruttore da ogni responsabilit civile e penale Utilizzare solo ricambi originali consigliati dal produttore La ditta produttrice non responsabile di inconvenienti rotture o incidenti dovuti al mancato rispetto o alla mancata applicazione delle indicazioni soprascritte e contenute nel manuale 4 EASY CRONO HR COLA 1 4 Descrizione tecnica La stufa funziona esclusivamente a pellet e diffonde nell ambiente un calore sano e sicuro sistemi di controllo automatici di cui dotata garantiscono una resa termica ottimale ed una combustione
39. protected externally by a grille gt or with direct connection to the outside with an appropriate pipe having a minimum internal diameter of 50 mm and maximum length of 1 5 m provided with antiwind protection at the end down bend The air inflow can also be obtained from a room adjoining that of installation provided the flow can occur freely through permanent openings to the outside the room must not be used as a garage for storing combustible materials or for activities with fire risk 2 4 Fume exhaust The fumes can be exhausted through a connection to a conventional flue or an external duct with double wall or insulated pipe The fume exhaust connections must guarantee a minimum draught of 10 Pa so that the evacuation of fumes is assured in case of a temporary power failure The installer must check the efficiency and state of the flue and its conformity with the local national and European regulations A Certified pipes and connections with adequate seals guaranteeing their tightness must be used In case of fire shut down the stove promptly call the fire department and avoid continual attempts to extinguish it Clean the flue and respective connection at least once a year 2 4 1Types of installation Listed below are definitions and requirements for correct installation of an exhaust flue in accordance with Italian Standard UNI10683 FLUE a vertical duct for collecting and expelling at an appropriate height
40. r gl ece Le po le ex cute successivement les phases de mise en route selon les param trages d finis qui en g rent les niveaux et les temps d ex cution jusqu l obtention du r gime normal moins que ne surviennent des anomalies ou ne se d clenchent des alarmes selon le tableau suivant tat Dur e Dispositifs Conditions pour passer l tat suivant mer Ve ans TEINT OFF OFF OFF OFF ON OFF START PR CHAUF OFF Apr s un laps de temps de Pr33 PRECHAUFFAGE ON OFF OFF Apr sunlaps de temps de Pr34 RECHARGEMENT DES z n G UL S Pr40 ON Apr s un laps de temps de Pr40 ATTENTE FLAMME P 41 ON Apres un laps de temps de Pr41 erh DES ON Apr s un laps de temps de Pr13 FEU PR SENT ON ON ON Apr s un laps de temps de Pr02 FONCTIONNEMENT OFF ON ON ON Temperature ambiante lt CONSIGNE temperature Temp rature des fum es lt Pr14 FONCTIONNEMENT Temp rature ambiante lt CONSIGNE temp rature MODULE or ON ON ON Temp rature des fum es lt Pr14 NETTOYAGE DU BRASIER p j7 OFF ON ON ON Avec une fr quence Pr03 FONCTIONNEMENT OFF ON ON ON ON OFF pour teindre NETTOYAGE FINAL Pr39 OFF ON OFF Pr39 S coule partir du moment o T fum es lt Pr13 73 EASY CRONO HR COLA Pass un certain temps si la temp rature des fum es atteint la valeur min admissible le po le se mettra en position d alarme Il est interdit d utiliser des
41. reinstatement y operations must be carried out by a service centre AL b ah The controller detects a faulty Reinstatement operations AUG TRIAC morethan 60 ses y gearmotor control relay must be carried out by a ERROR The system is st opp a contacts stuck service centre WAITING Occurs on relighting the stove Reset attempt in shutdown Alarm reset is possible only COOL immediately after having shut stage with stove hot in cooling after shutdown it down stage AIR FLOW The controller does not detect bce when theair tow the quantity of combustion air Reinstatement operations METER m ter iedisconn cied and does not shut down the must be carried out by a FAILURE stove it only excludes the air service centre flow meter functions Occurs when the stove has Cleaning extraordinary SERVICE exceeded 1800 hours of Extraordinary maintenance a 0 u DUE operation since the previous notice p servicing be carried out by a authorised service centre The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice The drawings measurements diagrams and any other configurations are given only by way of example 59 EASY CRONO HR COLA 8 ENCLOSURES CE MARKING INFORMATION CE COLA 2012 EN 14785 2006 Wood pellet burning domestic heating appliances Ref EASY CRONO HR Min safety distance from flammable materials
42. soft dry cloth to clean the ceramic surfaces the use of detergents could highlight any flaws 5 7 Cleaning the flue flue connection The flue connection must be cleaned at least once a year or whenever necessary depending on stove use and the type of installation Cleaning requires the suction and removal of the residuals in all the vertical and horizontal sections as well as the bends from the stove to the flue It is advisable to also clean the flue every year to ensure correct and safe evacuation of fumes For any maintenance or end of season cleaning COLA recommends contacting an authorised service A centre which will also check the wear on the stove s internal components 53 EASY CRONO HR COLA 6 MAINTENANCE 6 1 Introduction Operations on the internal parts of the stove must be carried out by qualified personnel Contact the nearest authorised service centre Make sure the stove is unplugged and cold before carrying out any work on it 6 2 Removing the cladding Key 1 Top ceramic cover 2 Bottom front panel 3 Rear panel 4 Gearmotor protection 5 Right side panel 6 Left side panel 7 Pellet hopper door 54 EASY CRONO HR COLA 6 3 Stove internal parts Key Combustion chamber 2 EASY CRONO HR right left supports 3 Cast iron exchanger
43. the fume exhaust outlet is blocked the vacuum switch detects the lack of a negative pressure inside the combustion chamber or the air flow meter detects a lack of air flow and through the electronic controller switches off the auger rotation motor signalling the anomaly with a message on the control panel AL 8 NO NEG PRESS or AL 9 INSUF DRAUGHT 3 3 Combustion chamber overpressure safety Any and or sudden overpressures in the combustion fumes inside the chamber and fume exhaust ducts are discharged by opening of the safety valves located on the heat exchanger During normal operation these valves are kept closed by their weight and the negative pressure in the combustion chamber guaranteeing a seal against any smoke escaping A Periodically check closing the integrity of the device and its operation 3 4 Overheating pellet hopper temperature safety thermostat A temperature probe is connected to a safety thermostat above the pellet chute which automatically interrupts the pellet supply in case of excessive heating gt 85 In this case the extractor and or fans continue working allowing the stove to cool down rapidly The fault is displayed on the control panel with a message AL 7 THERMAL SAF In case of activation proceed as follows Allow the stove to cool down for at least 45 minutes Reset the thermostat by pressing the button near the switch on the back of the stove after unscrewing the protection cap figure opposite
44. werden F e Der Sicherheitsthermostat hat eine Bo lese Alm ii muso Temperatur ber dem Schwelenwen cheer presina 1e AL 7 f r die berhitzung des unteren 9 THERMOSICHERUNG der Schneckenkanal Temperatur anspricht Das System wird gestoppt Beh lterabschnitts gemessen und unterbricht den Betrieb des Getriebemotors Den Betrieb des Thermostats durch Dr cken der Reset Taste wieder herstellen 117 EASY CRONO HR COLA Anzeige Betriebsst rung M gliche Ursachen Abhilfen Kontrollieren ob Rauchabzugsrohr und Brennkammer sauber sind Die Brennkammer ist verschmutzt Kontrollieren ob die T r dicht ii Das Rauchabzugsrohr ist verstopft verschlossen ist AL 8 Druck unter der Die Feuerraumt r ist nicht Kontrollieren ob die KEIN UNTERDRUCK Ansprechschwelle des Unterdruckw chters Das System wird gestoppt geschlossen Die Berstschutzventile sind offen verklemmt Der Unterdruckw chter ist defekt Berstschutzventile geschlossen sind Andere Vorg nge zur Wiederherstellung des Ofenbetriebs m ssen von einer autorisierten Kundendienststelle durchgef hrt werden Wird ausgel st wenn die Die Brennkammer ist verschmutzt Das Rauchabzugsrohr ist verstopft Kontrollieren ob Rauchabzugsrohr und Brennkammer sauber sind Kontrollieren ob die T r verschlossen ist dicht Die Feuerraumt r ist nicht Kontrollieren ob die E
45. werden die von den gem nachstehender Tabelle eingestellten Uhrzeiten begrenzt werden Die Einstellung OFF bedeutet dass die Uhr den Befehl ignorieren soll Auswahl Bedeutung M gliche Werte START 1 Aktivierungsuhrzeit ora OFF Deaktivierungsuhrzeit Aktivierungsuhrzeit Deaktivierungsuhrzeit Bei ffnen des Untermen s PROGRAM WOCHE k nnen die w chentlich programmierten Funktionen des Uhrenthermostats aktiviert deaktiviert und eingestellt werden Das Wochenprogramm verf gt ber 4 unabh ngige Programme deren Endeffekt aus der Kombination der 4 Programmierungen besteht Das Wochenprogramm kann aktiviert oder deaktiviert werden Durch Eingabe von OFF in das Feld mit den Stunden wird der entsprechende Befehl ignoriert durchgef hrt werden Darauf achten dass sich die Aktivierungs und oder Deaktivierungszeiten nicht am selben Tag in verschiedenen Programmen berlagern Die Programmierung muss mit gr ter Sorgfalt 107 117 J I 4 FRE GABE CHROnG Dialogfenster Mentieben Dialogfenster Dialogfenster EASY CRONO HR PROGRAMM 1 Meniiebene Auswahl Bedeutung M gliche Werte 03 03 02 START PROG 1 Aktivierungsuhrzeit 03 03 03 STOP PROG 1 Deaktivierungsuhrzeit ora OFF 03 03 05 MARTEDI PROG 1 on off 03 03 07 GIOVEDI PROG 1 on off Bezugstag 03 03 09 SABATO PROG 1 DOMENICA PROG 1 on off on off PROGRAMM 2 Meniie
46. 1 Reference day PROGRAMME 2 ora OFF on off on off on off on off on off Menu level Selection 03 03 11 START PROG 2 Activation time Possible values ora OFF STOP PROG 2 Deactivation time VENERDI PROG 2 PROGRAMME 3 03 03 20 START PROG 3 Activation time 03 03 21 STOP PROG 3 Deactivation time Reference day ora OFF on off on off on off on off Possible values ora OFF ora OFF 03 03 22 LUNEDI PROG 3 03 03 23 MARTEDI PROG 3 03 03 24 MERCOLEDI PROG 3 03 03 25 GIOVEDI PROG 3 03 03 26 VENERDI PROG 3 03 03 27 SABATO PROG 3 03 03 28 DOMENICA PROG 3 Reference day on off on off on off on off on off on off enni AMME 4 Menulevel Selection level Selection Meaning Possible values 03 03 29 START PROG 4 Activation time ora OFF 03 03 31 LUNEDI PROG 4 onoff MERCOLEDI PROG 4 gt on off VENERDI PROG 4 S on off SABATO PROG 4 gt onoff wen 49 COLA Dialogue box EASY CRONO HR COLA By accessing the submenu WEEK END PROGRAM it is possible to enable disable and set the week end Saturday 1436 Sunday chronothermostat functions Activate WEEK END programming only after pet usi J Li n J deactivating the weekly programming In order to avoid unwanted start and shutdown G OP AN operations activate only one programm
47. 4 Andere Vorg nge zur AL3 Abgastemperatur ber 280 mit A reese t Wiederherstellung des Ofenbetriebs HOT ABGASE misst berm ige Palia m ssen von einer autorisierten Der Abschaltvorgang wird 9 9 Kundendienststelle durchgef hrt aktiviert werden AL4 Wird ausgel st wenn das Das Saugzuggebl se ist blockiert Die Vorg nge zur Wiederherstellung SAUGZUGGEBL SE Saugzuggebl se defekt ist Der Drehzahlsensor ist defekt des Ofenbetriebs m ssen von einer Der Abschaltvorgang wird Das Saugzuggebl se wird nicht mit autorisierten Kundendienststelle DEFEKT aktiviert Strom versorgt durchgef hrt werden Kontrollieren ob der Beh lter Pellets 3 2 Der Pelletbeh lter ist leer enthalt AL 5 ii Der Heizwiderstand ist defekt Die Einschaltvorg nge kontrollieren ZUNDUNG gez ndet verschmutzt oder nicht in der korrekten Andere Vorg nge zur i Position eingebaut Wiederherstellung des Ofenbetriebs FEHLGESCHLAGEN oe wird Falsche Einstellung der m ssen von einer autorisierten i Pelletbeschickung Kundendienststelle durchgef hrt werden Kontrollieren ob der Beh lter Pellets i enth lt AL 6 g m a Pelletzuf hrung einstellen KEINE PELLETS Der Brenntopf wird nicht mit Pelletbeschickung muss sich einlaufen Andere Vorg nge zur Pellets versorgt 5 Wiederherstellung des Ofenbetriebs VORHANDEN Der Getriebemotor f hrt keine m ssen von einer autorisierten Pellets zu Kundendienststelle durchgef hrt
48. 4 7 1 Batterie wechseln 4 8 Thermostat Externer Uhrenthermostat 4 9 Au erbetriebnahme Ende der Heizperiode 5 REINIGUNG DES OFENS 5 1 Reinigung der Brennschale 5 2 Reinigung des Aschenbeh lters 5 3 Reinigung des Glases und der Luftschlitze 5 4 Reinigung des Saugzuggebl ses und der Brennkammer 5 5 Reinigung des Luftmassenmessers 5 6 5 6 Reinigung der Keramikteile 5 7 Reinigung des Rauchrohrs Schornsteinrohrs WARTUNG 6 1 Vorwort 6 2 Ausbau der Verkleidung 6 3 Innere Ofenkomponenten 6 4 Elektrische Bauteile FEHLERSUCHE 7 1 Verwaltung der Alarmmeldungen ANLAGEN 8 1 Informationen zur CE Kennzeichnung EASY CRONO HR COLA 1 ALLGEMEINE HINWEISE 1 1 Vorwort Verehrter Kunde Wir danken Ihnen f r das Vertrauen das Sie uns mit dem Kauf dieses Ger ts entgegengebracht haben Bitte lesen und befolgen Sie diese Installations Gebrauchs und Wartungsanleitung um die Produkteigenschaften optimal nutzen zu k nnen 1 2 Nachschlagen im Handbuch Der Hersteller beh lt sich vor die technischen Merkmale und das Design der Produkte jederzeit und ohne Vorank ndigung zu ndern Installation Bedienung und Wartung des Ofens m ssen den in diesem Handbuch enthaltenen Vorschriften sowie den europ ischen nationalen regionalen und kommunalen Gesetzen und Normen entsprechen Alle Abbildungen Ma e bersichtszeichnungen sowie s mtliche sonstigen Angaben in dieser Druckschrift dienen nur zur Veransc
49. 4 adjustable feet to facilitate positioning on not perfectly flat floors To adjust the height tilt the stove slightly and turn the feet as required The stove is supplied with the ambient sensor fixed through a wrapper on the back of the stove we recommend to remove the wrapper and to locate the sensor in the best position possible as to improve the temperature registration in accordance with the ambient context and the length of the cable As for temperature registration done at a certain distance we reccomend to install the ambient thermostat ambient programming clock thermostat see par 4 8 The stove cannot be installed in bedrooms bathrooms and in general in rooms where another heating unit is already installed without an independent air inflow With wooden floors install a floor protection base in conformity with the current regulations Suitable fire prevention devices should be arranged for any eventuality Do not install the stove in places with an explosive atmosphere 2 3 Air inlet The stove air inlet pipe or intake is located at the back and is round and 50 mm in diameter A quantity of air at least equal to that necessary for combustion must flow in the room where the stove is installed therefore the combustion air necessary to ensure correct operation of the stove must be drawn gt from the room provided there is a wall air inlet near the stove communicating with the outside and of minimum area 100 cm suitably
50. A 2 TRANSPORT ET INSTALLATION 2 1 Emballage manutention exp dition et transport Le po le peut tre soulev l aide d un chariot l vateur en introduisant les fourches d une longueur ad quate aux endroits pr vus cet effet sur la palette en bois S assurer que la capacit des appareils utilis s pour le levage et le transport est suffisante pour supporter le poids du po le indiqu sur la plaque d identification et dans ce manuel Eviter de passer dans des zones o la chute de la charge pourrait repr senter un danger Ouvrir l emballage retirer le po le de la palette et le poser l endroit choisi en veillant a sa conformit avec la commande Il est recommand de poser d licatement le po le au sol pour viter tout choc ventuel et de l installer dans la zone pr vue s assurer galement que le plancher est assez solide pour supporter le poids du po le dans le cas contraire consulter un technicien sp cialis L limination ou le recyclage de l emballage est a la charge de l utilisateur final en conformit avec la r glementation locale en vigueur 2 2 Lieu d installation mise en place et s curit anti incendie La pi ce dans laquelle le po le est install doit tre suffisamment a r e pour assurer une bonne vacuation en cas de fuite ventuelle de fum e de combustion L appareil peut fonctionner dans une habitation ayant une temp rature minimum de 0 Pour viter tout risque d incendie pr
51. COLA COLA Manuale d installazione uso e manutenzione Installation use and maintenance manual Manuel d installation d utilisation et d entretien Installations Bedienungs und Wartungsanleitung Stufa a pellet mod Pellet stove model Po le a granul s mod Pelletofen Modell EASY CRONO HR 484210441 M4_03 12 Hardware M Leggere attentamente le istruzioni prima dell installazione utilizzo e manutenzione Il manuale parte integrante dell apparecchio Read the instructions carefully before installation use and maintenance The manual is an integral part of the unit Lire attentivement les instructions avant d installer d utiliser et d entretenir le po le Le manuel fait partie int grante de l appareil Vor Installation Gebrauch und Wartung muss diese Anleitung aufmerksam durchgelesen werden Das Handbuch ist wesentlicher Bestandteil des Ger ts 1 EASY CRONO HR COLA La Ditta COLA garantisce i propri prodotti secondo le norme attualmente in vigore ad esclusione delle parti soggette a normale usura Per le condizioni di garanzia rivolgersi all importatore o al rappresentante autorizzato il quale pu integrare il periodo della garanzia obbligatoria con un periodo supplementare a sua totale ed esclusiva responsabilit La garanzia del prodotto decade per qualsiasi inconveniente rottura o incidente dovuto al mancato rispetto o applicazione delle indicazioni contenute nel presente manuale COLA g
52. CTIONNEMENT Diminue la valeur de la temp rature du thermostat d ambiance OFF i Permet d acc der au menu R glage menu MENU Permet d acc der au niveau de sous menu suivant 3 PROGRAMMATION Ajuste la valeur et fait passer l opion de menu suivante FONCTIONNEMENT Allume ou teint le po le si press pendant 2 secondes selon que celui ci est respectivement teint ou allum ON OFF 4 d blocage BLOCAGE D bloque le po le et le remet dans son tat teint MENU Se met au niveau de menu sup rieur Les modifications sont PROGRAMMATION m moris es FONCTIONNEMENT Modifie la puissance rendue du po le OFF i Cent Fait passer l option de menu suivante 5 Diminution de MENU up p la puissance PROGRAMMATION Revient l option de sous menu suivant Les modifications sont m moris es FONCTIONNEMENT Modifie la vitesse de l changeur OFF 6 Augmentation MENU Fait passer l option de menu pr c dente de la puissance Fait passer a l option de sous menu pr c dente Les modifications PROGRAMMATION Le sont memorisees contact externe ey chrono tw WEN r sistance lectrique La figure ci contre fournit l explication des indicateurs d tat sur la partie MAMI bougie gauche de l cran PA vis sans fin L activation l cran d un des segments signale la mise en service du SM aspirateur defum es dispositif correspondant suivant la liste ci contre Sen changeur non utilis
53. Der Ansauganschluss bzw der Lufteinlass des Ofens befindet sich im hinteren Teil und hat einen runden Querschnitt mit einem Durchmesser von 50 mm In dem Raum in dem der Ofen aufgestellt wird muss die einstr mende Luftmenge mindestens der notwendigen Verbrennungsluft entsprechen aus diesem Grund muss die Verbrennungsluft die notwendig ist um den regul ren Betrieb des Ger ts zu garantieren wie folgt angesaugt werden aus dem Raum sofern an einer Au enwand in Ofenn he ein mindestens 100 cm gro er und au en mit einem entsprechenden Gitter gesch tzter Au enlufteinlass vorgesehen ist oder ber eine direkte Verbindung nach au en durch ein geeignetes max 1 5 m langes Rohr mit einem Innendurchmesser von mindestens 50 mm und Windschutz Rohrkr mmer nach unten am Ende Die Luftzufuhr kann auch ber einen Raum neben dem Aufstellungsraum erreicht werden sofern sie frei ber bleibende ffnungen nach au en erfolgt dieser Raum darf nicht als Garage Brennstofflager oder f r mit Brandgefahr verbundene T tigkeiten dienen 2 4 Abgasf hrung Der Rauch kann durch den Anschluss an ein herk mmliches Schornsteinrohr oder an eine Au enleitung mit isoliertem oder doppelwandigem Rohr abgef hrt werden Die Anschl sse der Abgasf hrung m ssen einen Mindestzug von 10 Pa garantieren damit der Rauchabzug auch bei vor bergehendem Stromausfall sichergestellt ist Konformit t mit den rtlichen nationalen und europ ischen Vorschr
54. IRAGGIO d aria comburente sotto una La porta fuoco non chiusa Verificare la na delle INSUFF certa soglia Le valvole antiscoppio sono aBaresncenp le valvole antiscoppio a ri difettoso Altre operazioni di ripristino i devono essere condotte da un centro di assistenza AL b Re ne in II controllo rileva che il rel Le operazioni di ripristino ERRORE continuo e pi di 60 sec comando motoriduttore in devono essere condotte da un TRIAC COC ci sistema viene arrestato avaria contatti incollati centro di assistenza Tentativo di sblocco in fase di sblocco dell allarme sar ATTESA Avviene riaccendendo subito spegnimento con la stufa possibile solamentace RAFFRED dopo aver spento la stufa i spegnimento ultimato Il controllo non rileva la GUASTO Avviene quando il debimetro quantit d aria comburente poi operazioni di e ma non spegne la stufa evono essere condotte da DEBIMET viene sgollagata esclude solamente le funzioni un centro di assistenza del debimetro Avviene quando la stufa ha Le operazioni di pulizia superato le 1800 ore di Awd manutenzione straordinaria e pra funzionamento dal ee manutenzione di ripristino devono essere precedente intervento di manutenzione condotte da un centro di assistenza autorizzato La ditta si riserva di apportare in qualsiasi momento senza preavviso alcuno eventuali modifiche tecniche od estetiche ai prodotti diseg
55. NTE ON ON ON decorso tempo Pr02 LAVORO OFF ON ON ON temperatura ambiente SET temperatura temperatura fumi lt Pr14 ON OFF decorso tempo Pr41 wono __ om ox ox ox emam Ba PULIZIA BRACIERE Prl2 OFF ON ON ON con cadenza Pr03 LAVORO OFF ON ON ON ON OFF per spegnere PULIZIA FINALE Pr39 OFF ON OFF Pr39 decorre dal momento i n cui Tfumi lt Pr13 15 EASY CRONO HR COLA Trascorso un certo tempo se la temperatura fumi non ha raggiunto il valore minimo ammesso la stufa si pone in stato di allarme E vietato utilizzare liquidi infiammabili per l accensione In caso di continue mancate accensioni contattare il Centro di Assistenza 4 4 Fase di lavoro Conclusa in modo positivo la fase di AVVIO la stufa passa alla modalit LAVORO che rappresenta il normale modo di funzionamento L utente pu regolare la potenza di riscaldamento attraverso i pulsanti P5 e Pe dal valore massimo di 5 ad un valore minimo di 1 Temperatura ambiente Pulsante P6 9 Potenza impostata a 4 Oltre alla regolazione della potenza si pu pu anche regolare la temperatura ambiente direttamente sul pannello comandi attraverso i pulsanti P1 e P2 il display visualizza lo stato corrente del SET di temperatura Per la ventilazione dell aria calda la stufa regola automaticamente la velocit in funzione della potenza impostata Valore impo
56. OLA 3 7 S curit en cas de coupure de courant En cas de micro coupures de courant l appareil se rallume automatiquement Une coupure de courant momentan e ne limite pas le niveau de s curit du po le et la temp rature du r servoir n atteint pas des valeurs trop lev es lt 85 car la quantit de granul s dans le brasier est r duite Cette anomalie peut entra ner une l g re fuite de fum es dans la pi ce mais ne comporte aucun risque A Il est interdit d intervenir sur les dispositifs de s curit 3 8 Dysfonctionnement du ventilateur d extraction des fum es Si pour une raison quelconque le ventilateur d extraction des fum es s arr te de fonctionner l lectronique de commande bloque instantan ment l alimentation des granul s et affiche le message AL4 ASPIRAT DEFAILLANT 4 UTILISATION DU POELE 4 1 Introduction Le po le a granul s offre l avantage de combiner la chaleur de la flamme du bois et la commodit de la gestion automatique de la temp rature avec la possibilit de programmer hebdomadairement l allumage et d extinction Il est possible d effectuer le branchement a un thermostat et ou chronothermostat externe pour mesurer la temp rature en un endroit different de celui d installation du po le Pour une utilisation s re et fiable du po le respecter les points suivants il est possible de sentir de mauvaises odeurs lors de la premi re mise en service Par cons quent a rer correcte
57. R nta ZUG ea unter geschlossen Berstschutzventile geschlossen sind Schwellenwert liegt Die Berstschutzventile sind Andere Vorg nge zur i offen verklemmt Wiederherstellung des Ofenbetriebs Der Luftmassenmesser ist defekt m ssen von einer autorisierten Kundendienststelle durchgef hrt werden Wird ausgel st wenn der AL b Getriebemotor in Die Regelung hat festgestellt dass an Vorg nge Wiedererstellung les Ofenbetriebs m ssen von einer FEHLER TRIAC Dauerbetrieb und l nger als das Steuerrelais des Getriebemotors nee Kundandichefsiells SCHNECKE 60 Sek l uft defekt ist Kontakte verklebt Das System wird gestoppt durchgef hrt werden ABK HLEN BITTE Wird ausgel st wenn der Ofen sofort nach dem Entst rversuch w hrend des Abschaltvorgangs mit noch warmem Der Alarm kann erst zur ckgesetzt werden nachdem der Ofen WARTEN Ausschalten wieder Ag eingeschaltet wird Ofen in Abk hlphase vollst ndig abgeschaltet wurde Die Regelung kann die Menge der 5 Ahh 3 Die Vorg nge zur Wiederherstellung en ent das Onbeiebs m ssen von einer LUFTMASSENMESSER i 9 Je autorisierten Kundendienststelle wird sondern schlieBt nur die Funktionen i durchgef hrt werden des Luftmassenmessers aus Wird ausgel st wenn der Die Arbeiten f r au erordentliche SERVICE Ofen ii leizien Warhin Anforderung der au erordentlichen Reinigung Wartung und R cksetzung
58. Symbol der durchgekreuzten M lltonne auf dem Etikett des Ger ts bedeutet dass das Produkt am Ende seiner Nutzungsdauer von anderen Abf llen getrennt gesammelt werden muss 1 10 Anleitungen f r Eingriffsanforderungen und Ersatzteilbestellungen Zur Anforderung eines Eingriffs und oder f r Ersatzteilbestellungen wenden Sie sich bitte an Ihren H ndler den Gebietsimporteur oder an den n chstgelegenen Vertragskundendienst und geben Sie die folgenden Daten an Ofenmodell Seriennummer Kaufdatum Ersatzteilliste und Informationen ber die festgestellten Fehlfunktionen oder Betriebsst rungen Alle Eingriffe an den Komponenten m ssen von autorisiertem und oder qualifiziertem Personal A ausgef hrt werden Vor jedem Eingriff am Ofen ist immer die Stromversorgung zu unterbrechen Der Ofen muss kalt sein AusschlieBlich Original Ersatzteile benutzen 95 EASY CRONO HR COLA 2 TRANSPORT UND INSTALLATION 2 1 Verpackung Handhabung Versand und Transport Der Ofen kann mit einem Gabelstapler angehoben werden indem die ausreichend langen Gabeln an den passenden Stellen in der Holzpalette eingef hrt werden Es muss unbedingt sichergestellt werden dass die Hebe und Transportmittel f r das am Typenschild und im vorliegenden Handbuch angegebene Maschinengewicht geeignet sind Auf keinen Fall die Last in Bereichen bef rdern in denen das Herunterfallen eine Gefahr darstellen k nnte Die Verpackung ffnen den Ofen von der Palette abheb
59. Y CRONO HR COLA Evitare il passaggio del carico su zone nelle quali la caduta del carico pu essere un pericolo Aprire l imballo rimuovere la stufa dal bancale e posizionarla nel luogo prescelto facendo attenzione che sia conforme a quanto previsto Si raccomanda di adagiare la stufa sul pavimento con la massima cautela evitando qualsiasi urto e di posizionarla nella zona preposta inoltre indispensabile verificare la portata del pavimento in funzione del peso della stufa in caso contrario consultare un tecnico specializzato Lo smaltimento o il riciclaggio dell imballo a cura dell utente finale in conformit alle norme locali vigenti in materia 2 2 Luogo d installazione posizionamento e sicurezza antincendio L ambiente di installazione deve essere sufficientemente ventilato per consentire l evacuazione di eventuali piccole perdite di fumo di combustione L apparecchio idoneo al funzionamento in ambiente domestico con temperatura minima non inferiore a OT Per evitare il rischio di incendio necessario proteggere dal calore e dalle radiazioni del fuoco le strutture circostanti la stufa pavimenti in legno o in qualsiasi materiale infiammabile devono essere opportunamente protetti alla base con pannelli in acciaio o in vetro temperato la protezione dovr ricoprire oltre la base anche una certa area di fronte la stufa Eventuali travature e tavole in legno poste sopra e attraversate dalla canna fumaria de
60. a fumaria Collegare la stufa all aspirazione tramite un tubo o presa d aria dall esterno Collegare la stufa ad una presa elettrica a Norma tensione 230 V 50 Hz Verificare che l impianto elettrico e le prese abbiano la capacit di sopportare l assorbimento massimo dell apparecchio riportata sull etichetta e sul presente manuale Prima di ogni manutenzione staccare la spina elettrica dalla stufa ed operare solo con stufa fredda Non impiegare liquidi o sostanze infiammabili per accendere la stufa o per ravvivare la fiamma a stufa accesa l accensione del pellet automatica La stufa a pellet deve essere alimentata solo ed esclusivamente con pellet di legna aventi le caratteristiche descritte nel presente manuale La stufa non deve essere usata come inceneritore Non chiudere in alcun caso le aperture di ingresso dell aria comburente e uscita fumi E vietato manipolare sostanze facilmente infiammabili o esplosive nelle vicinanze della stufa durante il suo funzionamento Non rimuovere o modificare la griglia di protezione del serbatoio pellet ed in generale i dispositivi di sicurezza E vietato il funzionamento della stufa con la porta fuoco aperta e o vetro rovinato o rotto Durante il funzionamento il forte calore sviluppato dalla combustione del pellet surriscalda le superfici esterne della stufa in particolare la porta fuoco maniglia e tubo scarico fumi Evitare quindi di entrare in contatto con tali
61. aced by qualified personnel protect the stove from dust with suitable covering store in a dry and safe place protected from atmospheric agents 5 STOVE CLEANING Stove cleaning is very important to ensure correct operation and to prevent blackening of the glass poor combustion deposits of ash and unburnt products in the brazier reduced thermal efficiency The stove must only operate with the fire door closed The fire door seals must be checked periodically to prevent any air from entering the combustion chamber and pellet duct work in a negative pressure and the fume exhaust in a positive pressure Routine cleaning is normally carried out by the customer following the instructions in the manual whereas extraordinary maintenance at least once a year must be performed by the authorised Service Centre Dispose of cleaning waste in accordance with the current local regulations The stove must not be operated without its cladding Avoid the creation of smoke and unburnt products during lighting and or normal Cleaning operations for all parts must be carried out with the stove unplugged and cold operation Given below are the control and or maintenance operations for correct stove use and operation 1 year Parts Period ie 07 ae ee extraordinary Type of cleaning Hans i eu at cleaning carried out 9 9 9 9 by the Service Centre Brazier n Ash compartment pan n Glass n Baffle fume exchanger n
62. acht ist Rauchrohr Inspizierbare Kammer Au enlufteinlass min 100 cm Mindestabstand 0 2m 97 EASY CRONO HR COLA ABGASKANAL oder RAUCHROHR Leitung oder Verbindungsst ck zwischen Feuerst tte und Schornstein f r die Abf hrung der Verbrennungsprodukte Technische Anforderungen an den ABGASKANAL Der Abgaskanal darf keine R ume durchqueren in denen die Installation von Heizger ten verboten ist die Verwendung von Metallschl uchen oder Rohren aus Asbestzement ist verboten die Verwendung von Elementen mit Gegenneigung ist verboten in den waagerechten Abschnitten darf der Kanalverlauf max 3 Steigung haben Die L nge des horizontalen Abschnitts muss kurz gehalten werden und darf auf keinen Fall l nger als 3 m sein ohne T St ck darf nicht fter als 3 Mal die Richtung gewechselt werden bei Richtungswechsel gt 90 max 2 Rohrkr mmer mit einer horizontal gemessenen L nge von nicht ber 2 m verwenden Der Abgaskanal muss einen konstanten Querschnitt haben und das Auffangen von Ru gestatten SCHORNSTEINKOPF Vorrichtung am oberen Ende des Schornsteins die den Austritt der Verbrennungsprodukte in die Atmosph re erleichtert Technische Anforderungen an den SCHORNSTEINKOPF gleicher Querschnitt wie der Schornstein der Nutzquerschnitt darf nicht kleiner als das Zweifache des Schornstein Innendurchmessers sein der Schornsteinkopf muss das Eindringen von Regen und F
63. ambiante Bouton P1 Bouton P2 Lorsque la temp rature des fum es arrive la temp rature maximum r gl e sur le tableau de commande le message MODULA F apparait sur l cran et le po le active la proc dure j de modulation de flamme sans l intervention de l utilisateur Si la hl 436 temp rature des fum es d passe le 280C l alarme ALLARM S g rc p U HOT FUMI apparait alors et le po le active la proc dure d arr t ca Si le mode VEILLE STAND BY est active le po le s teint a ERALA L retardement apr s avoir atteint la CONSIGNE SET de temp rature Le red marrage ne se produira que lorsque la temp rature ambiante sera inf rieure une certaine valeur pr d finie par rapport la temp rature ambiante Od UL A en tre de dialogue Puissan pr r gl ece 74 EASY CRONO HR COLA Temp rature ambiante FI HE Pendant le fonctionnement normal a intervalles predefinis la 2 rc p y modalit NETTOYAGE BRASIER pour une dur e pr d finie est activ e x d UR E nEttOYAG 4 5 Extinction Fen tre de dialogue Puissan pr r gl ece Pour arr ter le fonctionnement du po le il suffit d appuyer sur le bouton P4 pendant 2 secondes environ La vis sans fin est imm diatement arr t e et le fonctionnement de l extracteur des fum es est amen a une vitesse lev e Sur l cran appara tra alors le message NETTOYAGE FINAL les
64. andards Standard UNI 10683 2005 Installation requirements for heat generators burning wood or other solid biofuels Standard UNI EN14785 2006 Requirements for design manufacture construction safety and performance instructions and marking together with the relevant test methods for approval of units burning pellets Standard CEI EN 60335 1 Safety of electrical appliances for domestic and similar use part 1 Standard CEI EN 60335 2 102 Safety of electrical appliances for domestic and similar use part 2 Standard CEI EN 55014 1 Electromagnetic resistance Requirements for electrical appliances electric tools and similar electric equipment Part 1 Emission of interference Standard CEI EN 55014 2 Electromagnetic resistance Requirements for electrical appliances electric tools and similar electric equipment Part 2 IMmunity Product family standard Standard CEI EN 61000 3 2 Limits for harmonic current emissions Input current 16 A per phase Standard CEI EN 61000 3 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with nominal current lt 16 A Standard CEI EN 62233 Measuring methods for electromagnetic fields of electrical household appliances and similar with reference to human exposure Standards DIN plus 51731 UNI EN 14961 2 O Norm M 7135 Standards regarding the specifications and classification of pellets 1 8 Dataplate The dataplate is visible on the
65. aufnahme gt Seriennummer Abmessung des Abzugrohrs gt Art des Brennstoffs Gr e des Ansaugrohres gt Nennwarmeleistung und reduzierte Leistung Mindestschornsteinzug gt Verbrauch bei Nenn und red Leistung gt AuBenabmessungen des Ofens gt Abgastemperatur bei Nenn und red Leistung Sicherheitsabstand von entflammbaren Materialien gt Thermischer Wirkungsgrad Gewicht gt Versorgungsspannung 1 9 AuBerbetriebsetzung des Ofens Wird der Ofen definitiv auBer Betrieb genommen muss er vom Stromnetz getrennt und die Pellets aus dem Beh lter entleert werden F r die Entsorgung muss der Ofen in einer robusten Verpackung verschlossen und nach Absprache mit den zust ndigen Stellen den geltenden gesetzlichen Bestimmungen entsprechend entsorgt bzw bei Kauf eines neuen gleichartigen Ger ts an den H ndler zur ckgegeben werden werden Gem Art 13 des gesetzesvertr Dekrets Nr 151 vom 25 Juli 2005 zur Umsetzung der Richtlinie 2002 96 EG vom 23 Februar 2003 ber Elektro und Elektronik Altger te Waste of Electrical and Electronic Equipment in Bezug auf Ma nahmen und Verfahren zur Vermeidung der Erzeugung von Elektro und Elektronikschrott bezeichnet auch als WEEE mit der die Wiederverwendung das Recycling und sonstige Formen der R ckgewinnung gef rdert werden sollen um die zu entsorgenden Mengen zu verringern und die T tigkeit der Personen die am Produktlebenszyklus teilnehmen zu optimieren Das
66. be cleaned at least once a year removing all combustion residuals from the internal baffles and flueways To do this remove the cover and the top front panel of the stove Remove the cast iron exchanger by undoing the fixing screws then clean the baffles and the chamber Also make sure to clean the fume extractor located under the chamber accessed by removing the inspection port located on the front lower part of chamber Every 3 4 months clean the inside walls insulating refractory of the combustion chamber using suitable equipment brushes and replace if necessary Every 1800 hours of operation by means of a message SERVICE DUE the stove signals the need for extraordinary maintenance not under warranty to be performed by qualified personnel who will carry out complete cleaning and reset the message A Any knocking or forcing can damage the fume extractor making it noisy during operation therefore it is advisable to have this operation carried out by qualified personnel 5 5 Cleaning the air flow meter The air flow meter it measures the flow of combustion air installed inside the inlet pipe requires periodical internal cleaning every 3 4 months using suitable equipment blowing compressed air or suitable brushes 5 6 Cleaning the ceramic surfaces ceramic models The ceramic tiles are handicraft products and therefore may have minor surface imperfections such as tiny spots or slight colour differences It is advisable to use a
67. bene Auswahl Bedeutung Moeliche Werte 03 03 11 START PROG 2 Aktivierungsuhrzeit ora OFF 03 03 12 12 STOP PROG 2 Deaktivierungsuhrzeit CO 13 LUNEDI PROG 2 03 03 14 MARTEDI PROG 2 03 03 15 MERCOLEDI PROG 2 03 03 16 GIOVEDI PROG 2 Ed on off w 03 03 17 VENERDI PROG 2 amp on off 03 03 18 18 SABATO PROG 2 on off PROGRAMM 3 03 03 20 START PROG 3 Aktivierungsuhrzeit 03 03 21 STOP PROG 3 Deaktivierungsuhrzeit ora OFF 03 03 22 LUNEDI PROG 3 on off 03 03 23 MARTEDI PROG 3 on off 03 03 24 MERCOLEDI PROG 3 on off M gliche Werte 03 03 25 GIOVEDI PROG 3 on on off 03 03 26 VENERDI PROG 3 A on off 03 03 27 SABATO PROG 3 gt on off 03 03 28 DOMENICA PROG 3 on off PROGRAMM 4 Bedeutung M gliche Werte 03 03 29 START PROG 4 Aktivierungsuhrzeit ora OFF 03 03 30 STOP PROG 4 Deaktivierunosuhrreit ora OFF 03 03 31 LUNEDI PROG 4 on off 03 03 32 MARTEDI PROG 4 onoff 03 03 33 MERCOLEDI PROG 4 on off 03 03 34 GIOVEDI PROG 4 m on off 050335 VENERDI PROG 4 i on off 03 03 36 SABATO PROG 4 S on off call Bei ffnen des Untermen s PROGRAM WOCHENENDE k nnen die Funktionen des Uhrenthermostats am Wochenende aktiviert deaktiviert und eingestellt werden Wochenende Samstag Sonntag Die Programmierung WOCHENENDE nur nach Deaktivierung der Wochenprogrammierung aktivieren Um ein unbeabsichtigtes Ein
68. blem Any tampering and or unauthorised replacements with non original parts of the stove can create a risk for the user s safety and relieves the manufacturer of any civil or penal liability Only use original replacement parts recommended by the manufacturer The manufacturer declines any liability for problems damage or accidents caused by failure to follow or apply the instructions contained in this manual 33 EASY CRONO HR COLA 1 4 Technical description The stove works exclusively on pellets providing healthy and safe heat in the room The stove s automatic control systems guarantee optimum heat output and complete combustion there are also safety systems to guarantee safe operation for the stove parts and for the user When correctly installed the unit works in any outside climatic conditions and in any case in critical conditions strong wind frost etc the safety systems can cut in shutting down the stove Structure Steel cast iron and majolica Combustion chamber steel and cast iron Heat output nominal reduced Nom output 9 29 kW Red output 2 58 kW Hourly consumption Nom output Red output Nom Output 2 2 kg h Red output 0 57 kg h Efficiency Nom output Red output Nom output 89 26 Red output 95 7 Fume outlet temperature Nom output Red output Nom output 182 2 Red output 80 2 CO emissions with 13 O2 Nom output 0 01 Red o
69. bt blockiert die elektronische Regelung sofort die Pelletzuf hrung und die Meldung AL4 FAN FAIL wird angezeigt 4 GEBRAUCH DES OFENS 4 1 Vorwort Der Pelletofen vereint die wohlige W rme von Holzfeuer mit der bequemen automatischen Temperaturregelung und der M glichkeit die Ein und der Ausschaltung f r die ganze Woche zu programmieren Der Ofen kann an einen externen Thermostat und oder Uhrenthermostat angeschlossen werden um die Temperatur fern vom Aufstellungsort des Ofens zu messen F r einen sicheren und zuverl ssigen Betrieb befolgen Sie bitte die nachstehenden Vorschriften Bei der Erstinbetriebnahme k nnen unangenehme Ger che auftreten daher sollten Sie f r eine gute Bel ftung des Raums sorgen Dies gilt vor allem f r die erste Betriebszeit Der Beh lter darf ausschlie lich mit Pellets beschickt werden beim Nachf llen vermeiden dass der Beutel mit der hei en Oberfl che des Ofens in Kontakt kommt Keinen anderen Brennstoff als Pellets die die Vorschriften erf llen in den Ofen einf hren Der Ofen darf nicht zur M llverbrennung verwendet werden Der Ofen darf ausschlie lich mit geschlossener Feuerraumt r betrieben werden Die Dichtungen der Feuerraumt r sind regelm ig zu pr fen um Luftinfiltrationen auszuschlie en Um eine guten Wirkungsgrad und einen einwandfreien Betrieb zu gew hrleisten muss der Brenntopf vor jeder Pelletbeschickung gereinigt werden Bei der ersten Inbetrieb
70. completa inoltre sono presenti dei sistemi di sicurezza atti a garantire un funzionamento sicuro sia per i componenti della stufa sia per l utente L apparecchio installato a norma funziona con qualsiasi condizione climatica esterna e comunque in condizioni critiche vento forte gelo ect possono intervenire i sistemi di sicurezza che spengono la stufa Struttura Acciaio ghisa e maiolica Camera di combustione acciaio e ghisa Potenza termica nominale ridotta P nom 9 29 kW P rid 2 58 kW Consumo orario combustibile P nom P rid P nom 2 2 kg h P rid 0 57 kg h Rendimento termico P nom P rid P nom 89 26 P rid 95 7 Temperatura uscita fumi P nom P rid P nom 182 2 P rid 80 2 Emissioni CO al 13 O2 P nom 0 01 P rid 0 02 Flusso gas di scarico P nom 6 5 g s P rid 2 2 g s Emissioni polveri P nom 6 1 mg m Tiraggio canna fumaria 10 14 Pa Tubo uscita fumi 80 mm Tubo presa d aria 50 mm Alimentazione elettrica 230V 50 Hz Assorbimento elenco 420 W max in fase di accensione 120 W per il normale funzionamento Distanza min sicurezza posteriore lato dx sx pavimento 200 300 0 mm Dimensioni mm H x L x P 990 x 582 x 499 mm Peso della stufa 98 kg Capacit serbatoio Litri 31 22kg Volume max riscaldabile 212 m Il consumo di pellet pu variare dal tipo di pellet utilizzato e dalla sua conservazione Considerando 35 W h per m
71. curatamente e se necessario sostituire eventuali parti danneggiate da parte di personale qualificato proteggere la stufa dalla polvere con idonea copertura sistemare in un luogo asciutto sicuro e riparato da agenti atmosferici 5 PULIZIA DELLA STUFA E importante procedere alla pulizia della stufa per garantire un corretto funzionamento ed evitare annerimento del vetro cattiva combustione deposito di cenere ed incombusti nel braciere minore efficienza termica La stufa deve funzionare solo ed esclusivamente con porta fuoco sempre chiusa Le guarnizioni porta fuoco devono essere controllate periodicamente per evitare infiltrazioni d aria infatti la camera di combustione ed il condotto di scarico pellet lavorano in depressione mentre con lo scarico fumi in leggera pressione Le operazioni di pulizia ordinarie vengono normalmente effettuate dal cliente seguendo le indicazioni del manuale mentre le manutenzioni straordinarie almeno 1 all anno devono essere svolte dal Centro Assistenza Tecnico autorizzato Le operazioni di pulizia di tutte le parti vanno eseguite a stufa completamente fredda ed elettricamente scollegata Smaltire i rifiuti della pulizia secondo le norme locali vigenti E vietato mettere in funzione la stufa priva dei rivestimenti esterni Evitare la formazione di fumo ed incombusti in fase di accensione e o durante il normale funzionamento Di seguito vengono riassunti gli interventi di co
72. de l eau reste au dessus de la temp rature de consigne SET pour une dur e pr d finie Le rallumage successif en mode automatique ne sera possible que lorsque la temp rature ambiante ou la temp rature de l eau descendra en dessous d une valeur pr d finie saisie dans le tableau des param tres 2 par d faut Les commandes manuelles effectu es en utilisant le tableau de commande ou la t l commande sont prioritaires par rapport la programmation 4 6 6 Menu 06 alarme sonore buzzer Cette option permet d activer ou de d sactiver une signalisation sonore du po le 4 6 7 Menu 07 chargement initial La pr s lection de l option CHARGE INITIAL permet d effectuer un pr chargement de granul s pour une dur e de 90 s le po le tant teint ou froid Appuyer sur le bouton P1 pour d marrer le chargement et appuyer sur le bouton P4 pour l interrompre seni DI CHAFSE int EI AL 4 6 8 Menu 08 tat du po le La s lection de cette option permet de visualiser l tat du po le dans l imm diat en indiquant la condition de fonctionnement des dispositifs reli s celui ci des crans sont ensuite successivement propos s pour le monitorage 4 6 9 Menu 09 r glages du technicien La s lection de cette option est r serv e uniquement au technicien agr de l assistance COLA comp tent les modifications ventuelles faites de mani re fortuite peuvent s rieusement endommager La modification des param
73. dello sportello serbatoio pellet o sulla parete posteriore della stufa Su di essa sono riportati i seguenti dati Modello Numero di matricola Tipo di combustibile Potenza termica nominale e ridotta Consumo alla Pnom e Prid Temperatura fumi alla Pnom e Prid Rendimento termico Tensione di alimentazione Potenza elettrica assorbita Dimensione tubo gas di scarico Dimensione tubo di aspirazione Tiraggio canna fumaria Dimensioni esterne stufa Distanza di sicurezza da materiali infiammabili Peso vvv vv v v v vvv vv v v 1 9 Messa fuori servizio della stufa Nel momento in cui si decide di non utilizzare definitivamente la stufa scollegare l alimentazione elettrica e scaricare completamente il pellet dal serbatoio Per provvedere allo smaltimento della stufa necessario sigillarla all interno di un robusto imballo e contattare gli organismi locali preposti per queste operazioni in modo da procedere secondo le norme locali vigenti oppure riconsegnarla al rivenditore al momento dell acquisto di una nuova apparecchiatura similare Ai sensi dell art 13 del Decreto Legislativo n 151 del 25 luglio 2005 di attuazione della Direttiva 2002 96 CE del 23 Febbraio 2003 sui Rifiuti di Apparecchiature Elettriche ed Elettroniche relative alle misure e procedure finalizzate a prevenire la produzione di rifiuti di apparecchiature elettriche ed elettroniche denominate RAEE promuovendo il reimpiego il riciclaggio e altre forme di recupero in
74. des Pelletsbeh lters 113 EASY CRONO HR COLA 6 3 Innere Ofenkomponenten SS pp G 2 Supporti dx sx EASY CRONO 3 Scambiatore in ghisa 5 Oberer Abweiser aus Vermiculit 4 Seitenw nde aus Vermiculit 6 R ckwand aus Vermiculit Zeichenerkl rung 1 Brennkammer Explosionszeichnung der Brennkammer und der damit verbundenen Teile Ofen EASY CRONO HR EASY CRONO HR 114 COLA Explosionszeichnungen von 1 Baugruppe Brenntopf 2 Baugruppe Saugzuggebl se 3 Baugruppe F rderschnecke Zeichenerkl rung 1 Brennschale 2 Brennschalenhalter 3 Baugruppe Verbrennungsluft Ansaugrohr 4 Elektr Widerstand 5 Hintere Dichtung des Brenntopfhalters 6 Vordere Dichtung der Ansaug Baugruppe Zeichenerkl rung 1 Spirale des Saugzuggebl ses 2 W rmedichtung 3 Saugzuggebl semotor 4 Rauchabzugsrohr Zeichenerkl rung 1 Dichtung Beh lter F rderer 2 Flansch f Getriebemotor 3 Getriebemotor 4 Schnecke 5 Dichtung f r Rutsche 6 Pelletsrutsche 7 Dichtung Kammer F rderer 8 Pelletsf rderer 115 EASY CRONO HR COLA 6 4 Elektrische Bauteile Zeichenerkl rung 1 Elektronikplatine 2 Kontroll und Sicherheits Unterdruckw chter 3 Sicherheitsthermostat 4 EIN AUS Schalter mit Schmelzsicherungen 5 Serielle Schnittstelle
75. deux moteurs d aspiration des fum es et de ventilation de l air fonctionneront jusqu ce que la temp rature du po le sera suffisamment basse va Puissan pr r gl ece Fen tre de dialogue Bouton P4 Sur l cran dans la fen tre de dialogue apparaitra l indication OFF au terme de l op ration Pendant la phase d extinction il n est pas possible de remettre en marche le po le jusqu ce que la temp rature des fum es n est pas descendue en dessous d une valeur pr d termin e pour une dur e pr d finie Dans la fen tre de dialogue appara t alors l indication ATTENTE REFROID 4 6 Menu Appuyer sur la touche P3 SET pour entrer dans le menu qui propose diff rentes options et diff rents niveaux permettant d acc der aux param trages de l lectronique de commande Le tableau ci apr s r sume la structure du menu avec les seules options disponibles pour l utilisateur Niveau 1 Niveau 2 Niveau 3 Niveau 4 Valeur 01 R glage des ventilateurs ee 7 02 r glage de l horloge 01 jour Jour 02 heures Heures 03 minutes Minutes 04 jour Jour 05 mois Mois 06 ann e Ann e 75 EASY CRONO HR COLA Niveau 1 Niveau 2 Niveau 3 Niveau 4 Valeur 03 r glage d
76. di valore prestabilito inserito nella tabella parametri default 2T I comandi manuali da pannello camandi o da telecomando sono prioritari rispetto alla programmazione Con la selezione OFF la stufa non attiva la modalit STAND BY e funziona normalmente attivando la funzione MODULAZIONE quando la temperatura supera il valore di SET 4 6 6 Menu 06 cicalino Con questa selezione possibile attivare o disattivare la segnalazione acustica della stufa 4 6 7 Menu 07 carico iniziale L impostazione del CARICO INIZIALE consente di effettuare a stufa spenta o fredda un precarico pellet per un tempo pari a 90 sec Si avvia con il pulsante P1 e si interrompe con il pulsante P4 Livello di menu Pulsante P1 4 6 8 Menu 08 stato stufa Con tale selezione possibile visualizzare lo stato istantaneo della stufa riportando la condizione di funzionamento dei vari dispositivi ad essa collegati per il monitoraggio sono disponibili diverse pagine poste in successione 4 6 9 Menu 09 tarature tecnico Tale selezione riservata al solo tecnico autorizzato del centro di assistenza COLA La modifica dei parametri tecnici sul menu 09 deve essere effettuata da personale autorizzato e competente eventuali modifiche fatte in modo casuale possono provocare gravi danni che escludono da qualsiasi responsabilit la ditta COLA 21 EASY CRONO HR COLA 4 7 Telecomando Il telecomando funziona con le impostazioni settate nel panne
77. dimento _ P nom 89 26 Energy efficiency Prid 95 7 Tipi di combustibile _ Pellet di legno Fuel types Wood pellets Potenza elettrica 420 Wmax 120w Rated input power Tensione nominale 230 V Rated voltage Fi inal requenza nominale 50 Hz Rated frequency 31 EASY CRONO HR COLA 1 GENERAL INFORMATION 1 1 Introduction 1 2 Using the manual 1 3 Safety rules 1 4 Technical description 1 5 Permissible use and fuel 1 6 Accessories supplied 1 7 Reference standards 1 8 Dataplate 1 9 Stove decommissioning 1 10 Instructions for requesting assistance and replacement parts 4 7 Remote control on request 4 7 1 replacing the battery 4 8 Thermostat external chronothermostat 4 9 Idle period end of season 5 STOVE CLEANING 5 1 Cleaning the brazier 5 2 Cleaning the ash container 5 3 Cleaning the glass and air slots 5 4 Cleaning the fume extractor and combustion chamber 2 TRANSPORT AND INSTALLATION nia 2 1 Packing handling shipment and transport 2 2 Place of installation positioning and fire 5 7 Cleaning the flue flue connection prevention safety 2 3 Air inlet 2 4 Fume exhaust 2 4 1Types of installation 2 5 Brazier and baffle position check 2 6 Electrical connection 2 7 Wiring diagram 2 8 Emergency 6 MAINTENANCE 6 1 Introduction 6 2 Removing the cladding 6 3 Stove internal parts 6 4 Electrical components 7 TROUBLESHOOTING 7 1 Alarm management 3 STOVE SAFETY 3 1 Safety distance from
78. donc D bloquer le thermostat en agissant de la vis sans fin THERMIQUE bloqu le fonctionnement du sur le bouton de r armement Le syst me est arr t motor ducteur 87 EASY CRONO HR COLA Signalisation Anomalie Causes probables Solutions V rifier l tat de propret du conduit de fum e et de la chambre de La chambre de combustion est combustion i A encrass e V rifier la fermeture herm tique de la AL 8 En marche le po le rel ve une Le conduit de fum e est obstru porte ABSENCE pression inf rieure au seuil de tarage i her 3 ci vac ostar ui i a n ui pas nn nn la fermeture des clapets anti DEPRESS i x Az Les clapets anti explosion son explosion Le syst me est arr t ouverts coinc s D autres op rations de Le vacuostat est d fectueux r tablissement du fonctionnement normal doivent tre effectu es par un centre d assistance V rifier l tat de propret du conduit de fum e et de la chambre de La chambre de combustion est combustion encrass e V rifier la fermeture herm tique de la AL 9 Cette alarme se d clenche lorsque le Le conduit de fum e est obstru porte TIRAGE flux d air comburant se situe en La porte de foyer n est pas ferm e V rifier la fermeture des clapets anti dessous d un certain seuil Les clapets anti explosion sont explosion INSUFF pets ouverts coinc s D autres op rations de Le d bitm tre est d
79. e at a time Deactivate the daily programme if the weekly UE E H End programme is required with this setting it is advisable to deactivate the week end programme 4 6 4 Menu 04 select language With this selection it is possible to select the dialogue language from those available entered in the menu and namely ITALIAN End OY FRENCH ENGLISH EnSLI SH GERMAN 4 6 5 Menu 05 standby mode Dialogue box With the selection of STANDBY mode ON selection the stove shuts down automatically after the room temperature has remained above the SET value for a fixed time The next automatic relighting will be possible only when the room temperature falls below the set value entered in the parameters table default 2 The manual commands from the control panel or remote control have priority over programming 4 6 6 Menu 06 buzzer With this selection it is possible to activate deactivate stove acoustic signalling 4 6 7 Menu 07 initial loading The setting of LOAD INITIAL allows pellet preloading for a time equal to 90 sec with the stove off or cold It is started with the button P1 and stopped with the button P4 Menu level Button P1 e a Button P4 4 4 6 8 Menu 08 stove status With this selection it is possible to display the instantaneous stove status giving the operating status of the various devices connected to it various pages placed in succession ar
80. e available for monitoring 4 6 9 Menu 09 settings by technician This selection is reserved for the authorised technician of the COLA service centre Modification of the technical parameters of menu 09 must be done by authorised and competent personnel any changes made at random can cause serious damage for which COLA declines any liability 50 EASY CRONO HR COLA 4 7 Remote control available on request The remote control works with the settings made in the control panel and allows stove lighting shutdown and adjustment of the required output and temperature Since this device transmits through an infrared diode it must be pointed at the receiver unit in the control panel The remote control allows the following operations ot a aN rs L LED lit up by pressing any button N IT Button P1 P6 Stove lighting shutdown Button P1 Increase room temperature Button P6 Increase output level Button P5 Decrease output level Button P2 Decrease room temperature 4 7 1 Replacing the battery The remote control comes without the battery it works with a battery placed in the lower part of the device To fit or replace the battery proceed as follows Open the cover on the back of the remote control Replace the 12V battery model p28ga respecting the polarity Close the remote control Check that it works properly The battery of the remote control must be replaced and disposed of in a safe
81. e current Regulations Make sure the electrical system is equipped with an earth and differential switch IN The power cable must never touch the stove exhaust pipe 2 7 Wiring diagram System 230V Igniter Baffle Fume extractor Encoder for Fume extractor ALT Main safety Thermostat Fume Roo ALD vacuum switch probe Thermostat 40 EASY CRONO HR COLA 2 8 Emergency Suitable fire prevention devices should be arranged for any eventuality In case of a fire proceed as follows Immediately disconnect the plug A Extinguish the fire using suitable fire extinguishers Call the fire department immediately Do not use jets of waters to extinguish the fire 3 STOVE SAFETY 3 1 Safety distance from flammable materials To prevent the risk of fire stove positioning must respect a minimum distance from flammable materials according to that given in the technical table of the manual and on the dataplate Pay attention to the type of floor for delicate and flammable materials it is advisable to use plates in steel or toughened glass as a support base see section 2 Transport and Installation In case of particularly fragile objects such as furniture curtains or sofas increase the stove distance considerably 3 2 Fume exhaust safety In normal operation the combustion chamber is in a negative pressure guaranteeing seal against possible smoke leaks in the room If a certain vacuum level is not reached or
82. e normalement effectu es par le client en suivant les indications du manuel L entretien extraordinaire est par contre effectu par le centre d assistance agr au moins une fois par an Eliminer les d chets du nettoyage conform ment la r glementation locale en vigueur Il est interdit d allumer le po le s il est d pourvu de son habillage Eviter la formation de fum e ou d imbril s pendant l allumage et ou le fonctionnement normal N Les operations de nettoyage de toutes les parties doivent tre faites po le froid et d branch Voici le tableau r capitulatif des interventions de contr le et ou d entretien utiles pour le fonctionnement correct du o le Organes ou parties 1 jour 2 3 jours 1 mois 2 3 mois Jan P riode nettoyage nettoyage nettoyage nettoyage min a Op ration courant courant courant courant dassistarice Brasier n Cendrier n Vitre n Echangeur fum es n d flecteur Collecteur extracteur de n fum es a Joint de porte vitre n Conduit de fum e conduit n de raccordement 5 1 Nettoyage du brasier Enlever le brasier et liminer les r sidus de cendre qui se sont d pos s dans la chambre de combustion et dans le support de brasier Il est conseill d utiliser un aspirateur appropri Cette op ration doit tre effectu e tous les jours surtout en pr sence de d p ts d imbril s pour permettre l air de comb
83. e vigenti Per ogni evenienza consigliabile disporre di idonei dispositivi antincendio E vietato il posizionamento della stufa in ambienti con atmosfera esplosiva 2 3 Presa d aria L attacco di aspirazione o presa d aria della stufa collocato posteriormente ed di sezione circolare con diametro paria50 mm Nel locale dove viene installata la stufa deve affluire una quantit d aria almeno pari a quello necessaria alla combustione per questo motivo l aria di combustione necessaria a garantire il regolare funzionamento dell apparecchio deve essere aspirata gt dall ambiente a condizione che in prossimit della stufa sia praticata una presa d aria a parete comunicante con l esterno di superficie libera minima di 100 cm opportunamente protetta esternamente da una griglia gt oppure con collegamento direttamente all esterno con un appropriato tubo di diametro interno minimo di 50 mm e lunghezza massima di 1 5 m provvisto all estremit di una protezione antivento curva verso il basso L afflusso dell aria pu essere ottenuto anche attraverso un locale adiacente a quello d installazione purch tale flusso possa avvenire liberamente attraverso aperture permanenti comunicanti con l esterno tale locale non pu essere adibito ad autorimessa magazzino di materiali combustibile o ad attivit con pericolo d incendio 2 4 Scarico fumi di combustione Lo scarico fumi pu essere fatto attraver
84. eb udeart und Klimazone variieren 92 EASY CRONO HR 990 Zeichenerkl rung A Luftgitter B Netzkabelanschluss C Verbrennungsluftansaugung Durchm 50 mm D Anschluss Rauchabzugsrohr Durchm 80 mm E T r des Pelletsbeh lters 93 516 COLA 499 0200000000000 0000090090000 nboasaascaasad 000000000000 Abmessungen Pelletofen EASY CRONO HR EASY CRONO HR COLA Um die T r zu ffnen den mitgelieferten Griff einsetzen und Griff zum ffnen Schlie en der im Uhrzeigersinn drehen Feuerraumt r ffnen Im Uhrzeigersinn Schlie en Gegen den Uhrzeigersinn ne 1 5 Brennstoff und zulassiger Gebrauch Die Pellet fen funktionieren ausschlieBlich mit Pellets Presslingen aus verschiedenen Holzarten die die Vorschriften der Normen DIN Plus 51731 oder UNI EN14961 2 oder O Norm M 7135 erf llen bzw folgende Eigenschaften aufweisen Heizwert min 4 8 kWh kg 4180 kcal kg Dichte 680 720 kg m3 Feuchtigkeit max 10 des Gewichts Durchmesser 6 0 5 mm Anteil Asche max 1 5 des Gewichts Lange min 6 mm max 30 mm Zusammensetzung 100 unbehandeltes Restholz aus der Holzindustrie oder aus Recycling ohne Zugabe von Bindestoffen und ohne Rinde gem den geltenden Vorschriften Verpackung in Beuteln aus Okomaterial bzw biologisch abbaubarem Material oder Papier Der Pelletbeh lter befindet sich im hinteren Be
85. ehle und die w hrend der Programmierung oder Einstellung der Betriebsparameter jeweils angezeigten Meldungen aufgef hrt 101 EASY CRONO HR COLA Taste Beschreibung Betriebsart Vorgang PROGRAMMIERUNG Gew hlten Meniiwert ndern erh hen 1 Temperatur erh hen ARBEIT OFF Temperaturwert des Raumthermostats erh hen PROGRAMMIERUNG Gew hlten Men wert ndern verringern Temperatur 2 verringern ARBEIT OFF Temperaturwert des Raumthermostats verringern MEN ffnen 3 Set Men MENU N chste Untermen Ebene ffnen PROGRAMMIERUNG Wert einstellen und zum n chsten Men punkt wechseln ARBEIT 2 Sekunden dr cken um den ausgeschalteten Ofen ein bzw l den eingeschalteten Ofen auszuschalten Den Ofen r cksetzen und wieder ausschalten ON OFF 4 Freigabe MENU Zur n chsth heren Men ebene wechseln die vorgenommenen i PROGRAMMIERUNG Anderungen werden gespeichert ARBEIT OFF Leistungsabgabe des Ofens ndern Leistungsstufe MENU Zum n chsten Men punkt wechseln erh hen PROGRAMMIERUNG Zum n chsten Untermen punkt wechseln die vorgenommenen Anderungen werden gespeichert ARBEIT OFF Drehzahl des W rmetauschers ndern Leistungsstufe Zum vorherigen Men punkt wechseln 6 verringern MENU PROGRAMMIERUNG Zum vorherigen Untermen punkt wechseln die vorgenommenen Anderungen werden gespeichert n Externer Kontakt D Uhrenthermostat Auf der nebenstehenden Abbildung ist die Bedeu
86. ella stufa consigliabile togliere il cavo di alimentazione dalla stessa differenziale secondo le Norme vigenti Assicurarsi che l impianto elettrico sia a norma provvisto della messa a terra e dell interruttore IN Il cavo di alimentazione non deve mai toccare il tubo di scarico della stufa 2 7 Schema elettrico RETE 230V CANDELETTA SCAMBIATORE ESTRATTORE FUMI encoder ventilatore fumi ALT termostato sicurezza generale ALD depressimetro supplementare termostato ambiente 11 EASY CRONO HR COLA 2 8 Pronto intervento Per ogni evenienza consigliabile disporre di idonei dispositivi antincendio Se si manifesta un incendio procedere come segue Scollegare immediatamente la presa di corrente Spegnere tramite l uso di idonei estintori Richiedere l immediato intervento dei vigili del fuoco Non spegnere il fuoco con l uso di getti d acqua 3 SICUREZZE DELLA STUFA 3 1 Distanza sicurezza da materiali infiammabili L apparecchio va collocato ad una distanza minima perimetrale da materiali infiammabili al fine di evitare pericoli di incendio secondo le indicazioni presenti nella tabella tecnica del manuale e riportate nella targa dello stesso Porre attenzione alla tipologia del pavimento per materiali delicati ed infiammabili si raccomanda l utilizzo di piastre in acciaio o vetro temperato come base di appoggio vedere capitolo 2 Trasporto ed Installazione In caso di presenza di o
87. ello di menu superiore le modifiche effettua PROGRAMMAZIONE te sono memorizzate LAVORO SPENTO Modifica la potenza resa dalla stufa Decrementa MENU Passa alla voce di menu successiva potenza th PROGRAMMAZIONE Toma alla voce di sottomenu successivo le modifiche effettuate sono memorizzate LAVORO SPENTO Modifica la velocit dello scambiatore 6 Incrementa MENU Passa alla voce d menu precedente potenza Passa alla voce di sottomenu precedente le modifiche PROGRAMMAZIONE i effettuate sono memorizzate contatto estemo crono La Figura a fianco descrive il significato dei segnalatori di stato sulla parte canalons sinistra del display J coclea L attivazione nel display di uno dei segmenti segnala l attivazione del aspiratore fumi dispositivo corrispondente secondo l elenco a fianco ESSERE non usato allarme 14 EASY CRONO HR COLA 4 3 Accensione 4 3 1 Controllo prima dell accensione Prima di procedere con l accensione della stufa necessario verificare i seguenti punti assicurarsi di aver letto e compreso quanto riportato nel manuale il serbatoio deve essere carico di pellet la camera di combustione deve essere pulita il braciere deve essere completamente libero pulito da eventuali residui di combustione e posizionato correttamente nella sede del portabraciere verificare la chiusura ermetica della porta fuoco e del cassetto cenere verificare il collega
88. en 1 und 5 eingestellt werden wird zum Beispiel der Wert 3 eingestellt erh hen die L fter automatisch die Drehzahl ohne jedoch die eingestellte Drehzahlstufe 3 zu bersteigen In der kanalisierbaren Ausf hrung wird der elektrische Anschluss durch Aufleuchten der zwei LED Segmente B angezeigt 4 6 2 Men 02 Uhr einstellen Die elektronische Regelung ist mit einer 3 Volt Lithiumbatterie Typ CR2032 ausgestattet dank der die interne Uhr eine Autonomie von ber 4 5 Jahren hat falls die Uhr bei ausgeschaltetem Ofen die Uhrzeit nicht gespeichert h lt oder wenn bei Wiedereinschalten eine Reihe von Nullen angezeigt wird muss die Batterie vom Kundendienst ausgewechselt werden 4 6 3 Men 03 Uhrenthermostat aktivieren Dient zur Aktivierung und Deaktivierung aller Funktionen des Uhrenthermostats bei Wahl auf ON wird die Funktion aktiviert und das entsprechende LED Segment D leuchtet auf Bei Eingabe der Tagesprogrammierung G Wochenprogrammierung S bzw Wochenendprogrammierung W leuchtet im oberen Displayabschnitt rechts das jeweilige LED Segment C auf Was die Auswahl der Optionen und die Eingabe der Uhrzeiten betrifft m ssen die sechs Tasten gem den Anleitungen in der Tabelle von Absatz 4 2 bet tigt werden Bei ffnen des Untermen s PROGRAM TAG k nnen die t glich programmierten Funktionen des Uhrenthermostats aktiviert deaktiviert und eingestellt werden Es k nnen zwei Betriebsphasen eingestellt
89. en und am Aufstellungsort platzieren der den Anforderungen entsprechen muss Der Ofen sollte mit u erster Vorsicht an der gew nschten Stelle abgestellt werden wobei St e zu vermeiden sind Au erdem unbedingt die Tragf higkeit des Fu bodens in Bezug auf das Ofengewicht pr fen und gegebenenfalls einen Fachmann zu Rate ziehen Die Verpackung muss vom Endbenutzer gem den einschl gigen rtlichen Bestimmungen entsorgt bzw dem Recycling zugef hrt werden 2 2 Aufstellungsort Aufstellung und Brandschutz Der Raum in dem der Ofen aufgestellt wird muss ausreichend bel ftet sein damit eine Austragung eventueller geringf giger Abgasaustritte gew hrleistet ist Der Ofen eignet sich f r das Beheizen von R umen mit einer Mindesttemperatur von 0 Zur Vermeidung von Br nden m ssen die Strukturen um den Ofen herum vor der Hitzeeinwirkung und der W rmestrahlung des Feuers gesch tzt werden Holzfu b den oder Fu b den aus entz ndbarem Material m ssen mit Platten aus Stahl oder geh rtetem Glas gesch tzt werden der Schutz muss au er der Ofenbasis auch einen bestimmten Bereich vor dem Ofen bedecken Tragwerke aus Holz und aufgesetzte Holztafeln durch die das Schornsteinrohr l uft m ssen gem den geltenden Installationsvorschriften auf angemessene Weise gesch tzt werden Der Sicherheitsabstand entflammbarer Gegenst nde von der Ofenfront betr gt mindestens 1 5 m Der Sicherheitsabstand von entflammbaren Materialien muss
90. ene attivata la procedura di scheda centro di assistenza spegnimento Avvi j Il ventilatore tangenziale AWNING NAI caso cui la sonda difett 9 Regolare l afflusso del pellet fumi rilevi una temperatura dei ITETTOSO SEA AL 3 fumi superiore a 280 Manca l alimentazione ai Altre operazioni di ripristino HOT FUMI Viene attivata la procedura di ventilatore tangenziale hey ni gaun spegnimento Eccessivo carico pellet CENIO Ol asa ees Il ventilatore fumi bloccato AL 4 Avviene quando il ventilatore Ru cina ol a Il sensore controllo velocit Le operazioni di ripristino di aspirazione fumi guasto ASPIRAT Mena attivata la procedura di guasto devono essere condotte da GUASTO spegnimento Manca l alimentazione un centro di assistenza elettrica al ventilatore fumi Il serbatoio del pellet vuoto i SI AL 5 In fase di accensione non La resistenza elettrica N ifi di di arte la fiamma difettosa sporca o fuori dalla en MANCATA P i ena accensione Viene attivata la procedura di corretta posizione lirica ACCENS Altre operazioni di ripristino spegnimento Taratura carico pellet non devono essere condotto da corretta un centro di assistenza AL 6 Il serbatoio del pellet vuoto e leda Si Non viene alimentato di il imptoriduttore di carica pellet Regolare l aflusso del pellet MANCANO deve assestarsi ee pellet il braciere Al motarid ttote nan canes A
91. enus proceed as follows press the SET button P3 press the buttons P5 P6 to scroll the various menus press one of the increase decrease buttons P1 P2 to set the required parameter press the SET button P3 to confirm the parameter value On accessing the menu it is possible to obtain the various types of displays and carry out the available settings depending on the access level Given below is the table of controls and respective messages displayed during programming or setting operation parameters Button Description Mode Action PROGRAMMING Modify increase selected menu value Increase 1 temperature WORK OFF Increase room thermostat temperature value PROGRAMMING Modify decrease selected menu value 2 Decrease temperature WORK OFF Decrease room thermostat temperature value Access MENU 3 Setting menu Access next submenu level Set value and go to next menu item Presa for 2 seconds to switch the stove on or off if off or on ON OFF 4 reset Resets the stove and returns it to off status MENU Goes to higher menu level The modifications made are PROGRAMMING memorised WORK OFF Modifies stove heat output 5 Decrease MENU Go to next menu item power i i PROGRAMMING Return to next submenu item The modifications made are imemorised WORK OFF Modifies exchanger speed 6 Increase MENU Go to previous menu item power PROGRAMMING Go to previous submenu item
92. er une copie de celui ci au centre d assistance technique autoris afin qu il reste toujours avec l appareil Ce symbole indique la pr sence d un message important auquel pr ter une attention particuli re car la non observation des instructions peut entra ner de s rieux dommages au po le et aux personnes Une information n cessitant une attention particuli re est mise en vidence par un texte crit en Caract res gras 1 hi Regles de s curit Lire attentivement ce manuel avant l installation l utilisation et l entretien du po le Pour l installation le branchement lectrique la mise a l essai et l entretien vous adresser a un technicien qualifi et ou agr Raccorder le po le au conduit de fum e a l aide d un terminal qui puisse tre inspect le raccordement a plusieurs appareils peut se faire uniquement dans le respect des normes locales et autoris par l organisme de contr le du conduit de fum e Raccorder le po le de l ext rieur la bouche d aspiration a l aide d un tuyau ou d une prise d air Raccorder le po le une prise de courant homologu e de 230 V 50 Hz V rifier que l installation lectrique et les prises soient en mesure de supporter l absorption maximum de l appareil figurant sur l tiquette et sur le manuel Avant de proc der aux op rations d entretien d brancher le po le et attendre qu il soit froid Ne pas utiliser de liquides ou substance
93. er without the possibility of changing the parameters Room temperature Dialogue box Button P4 The stove carries out the startup stages in sequence according to the procedures defined by the parameters that manage levels and times reaching the work condition unless anomalies or alarms occur according to the following table Status Duration Devices Conditions for going to next status crea ci Auger Exch OFF OFF OFF ON OFF START CLEANING Pr33 OFF OFF After time Pr33 PREHEAT me OFF OFF After timePr34 PELLET PREFILL Pr40 N N After time Pr40 WAITING FLAME Pr41 ON PELLET LOAD ON Fume temperature gt Pr13 FIRE PRESENT ON ON ON After time Pr02 work er ow on o Ae MODULATES WORK cia ON ON Room temperature lt SET temperature Fume temperature lt Pr14 After timePr41 BRAZIER CLEANING Pri ON ON EveryPr03 WORK OFF ON ON ON ON OFF to switch off FINAL CLEANING Pr39 OFF ON OFF Pr39 starts from when fume T lt Pr13 44 EASY CRONO HR COLA After a certain time has elapsed if the fume temperature has not reached the minimum permissible value the stove goes in alarm status Do not use flammable liquids to light the stove In case of persistent failed lighting contact the Service Centre 4 4 Work stage After the STARTUP stage the stove goes to the WORK mode which represents the normal operation mode The user can adjust the heat o
94. ermostat functions prog activate this function and it appears the led D related to it When the daily weekly or week end program is set you can see on the upper right side of the display it appears the led C Menu level By accessing the submenu DAY PROGRAM the daily chronothermostat functions can be enabled disabled and set It is possible to set two operation phases delimited by the times A set according to the following table where the OFF setting tells 3 117 J g Od the clock to ignore the command CT 5 FARE Selection Meaning Possible values i d A J START 1 Activation time ora OFF ea Deactivation time Activation time Deactivation time Dialogue box 48 EASY CRONO HR By accessing the submenu WEEK PROGRAM it is possible to enable disable and set the weekly chronothermostat functions The weekly programmer has 4 independent programmes whose final effect consists of a combination of the 4 programmings The weekly programmer can be activated deactivated also by setting OFF in the times field the clock ignores the corresponding command Carry out programming making sure not to overlap the A hours of activation and or deactivation on the same day in different programmes PROGRAMME 1 Menu level Selection Meaning Possible values 03 03 03 STOP PROG 1 Deactivation time 03 03 05 MARTEDI PROG 1 03 03 07 GIOVEDI PROG 1 03 03 09 SABATO PROG 1 DOMENICA PROG
95. es which can appear on the control panel are listed below ALARMS MESSAGES Signalling Fault Possible causes Cures Turn the stove OFF by AL 1 pressing the button P4 and 4 No power during the lighting repeat the lighting procedure POWER The stove does not start stano siva FAILURE operations must be carried out by a service centre AL 2 conre N ie Faulty probe Reinstatement operations temperature probe fault ds FUME The shutdown procedure is ne probe is disconnected must be carried out by a PROBE activated from the board service centre rei So Faulty tangential fan Adjust the pellet flow AL 3 ue 280 p No power to tangential fan Other reinstatement HOT FUMES The shut down wbaduraie Too many pellets operations must be carried out activated by a service centre AL 4 o a Ine exvialistian The fume fan is blocked Reinstatement operations FAN FAIL The shutdown procedure is ly speed conio sensor must be cared out by a activated p i Check pellets in hopper MI The pellet hopper is empty Check the lighting AL 5 nn The electrical element is faulty procedures NO IGNITION p dirty or not correctly positioned Other reinstatement activated Pellet load setting incorrect operations must be carried out by a service centre The pellet hopper is empty Check pellets in hopper AL6 The pellet feed gearmotor has Adjust the pellet flow Brazier not
96. es Ger ts geeignet sein die auf dem Etikett und im vorliegenden Handbuch angegeben ist Vor jeder Wartung den Stecker aus dem Ofen ziehen und nur am kaltem Ofen Eingriffe vornehmen Keine entflammbaren Fl ssigkeiten oder Substanzen verwenden um den Ofen anzuz nden bzw die Flamme wieder anzufachen Bei eingeschaltetem Ofen erfolgt das Anz nden der Pellets automatisch Der Pelletofen darf ausschlie lich mit Pellets beschickt werden die die in dieser Anleitung beschriebenen Eigenschaften aufweisen Der Ofen darf nicht zur M llverbrennung verwendet werden Die Ein und Auslass ffnungen f r die Verbrennungsluft auf keinen Fall schlie en oder verdecken W hrend des Ofenbetriebs ist der Umgang mit leicht entflammbaren oder explosiven Stoffen in der Nahe des Ofens untersagt Das Schutzgitter des Pelletsbeh lters und im Allgemeinen die Sicherheitseinrichtungen nicht entfernen oder ver ndern Der Ofen darf nicht mit offener Feuerraumt r und oder mit besch digter oder zerbrochener Glasscheibe betrieben werden W hrend des Betriebs heizt die von der Pelletverbrennung erzeugte intensive W rme die Au enfl chen des Ofens stark auf Dies gilt besonders f r die Feuerraumt r den Griff und das Rauchrohr Vermeiden Sie daher jede Ber hrung mit diesen Teilen ohne entsprechende Schutzausr stung Bewahren Sie nicht hitzefeste und oder entflammbare Gegenst nde in ausreichendem Sicherheitsabstand zum Ofen auf Den Brennto
97. es sur le tableau de commande sont les suivantes ALARMES MESSAGES Signalisation Anomalie Causes probables Solutions Mettre le po amp le en position OFF en appuyant sur la touche P4 et r p ter ALi Le courant n arrive pas au po le la proc dure d allumage COUPURE DE Le po le ne s allume pas pendant la phase d allumage D autres op rations de COURANT r tablissement du fonctionnement normal doivent tre effectu es par un centre d assistance AL 2 Cette alarme se d clenche en cas a sonde set d tailanie D autres op rations de SONDE DE d anomalies de fonctionnement dela 2 Sonde est d branch e de la carte tablissement du fonctionnement TEMPERATUR sonde de temp rature des fum es normal doivent tre effectu es par un E DES FUM ES La proc dure d extinction est activ e lectronique centre d assistance Cette alarme se d clenche dans le Le ventilateur tangentiel est R gler l alimentation des granul s AL 3 cas o la sonde rel ve une a dda nlanive vaga D autres op rations de FUMEES temp rature des fum es sup rieure entilateur tan sai p r tablissement du fonctionnement BR LANTES 280 Chargement i de aianui s normal doivent tre effectu es par un La proc dure d extinction est activ e 9 9 centre d assistance AL4 Cette alarme se d clenche lorsque le T ci lee rs Les op rations de r tablissement du ASPIRAT ventilateur d aspiratio
98. fed with pellets to adjust Other reinstatement NO PELLETS The gearmotor does not feed operations must be carried pellets out by a service centre The safety thermostat has AL 7 Occurs in case of cutting in of detected a temperature above Check the cause of excessive THERMAL auger duct temperature safety the setting threshold due to overheating SAF thermostat overheating of the bottom part Reset the safety thermostat The system is stopped of the hopper blocking gearmotor operation by pressing the reset button 58 EASY CRONO HR COLA Signalling Fault Possible causes Cures Check cleanness of the fume The combustion chamber is i cam pusuan In the work stage the stove dirty Check hermetic vocina the AL 8 detects a pressure below the The fume duct is obstructed door 9 NO NEG vacuum switch setting The fire door is not closed cuci PRESS threshold The overpressure valves are overpressure se Na SY SIEM SIOUDEU a ze Other reinstatement y operations must be carried out by a service centre Check cleanness of the fume The combustion chamber is duel ane CORISNSEION chamber olny Check hermetic closing of the AL 9 Appears when the The fume duct is obstructed door INSUFF combustion air flow is belowa The fire door is not closed Chede gloei a iha DRAUGHT certain threshold The overpressure valves are 9 Sper stick overpressure valves ai ajr o met r Other
99. g 4 on off 37 Sunday prog 4 on off 04 week end program 01 week end chrono on off 02 start 1 03 stop 1 04 start 2 05 stop 2 47 EASY CRONO HR COLA Level 1 Level 2 Level 3 Level 4 Value 04 Select language 01 Italian set 02 French set 03 English set 04 German set 05 Standby mode on off 06 Buzzer on off 07 Initial loading set 08 Stove status 4 6 1 Menu 01 adjust fans The speed of the air fans is authomatic and follows the maximum power programmed If you want to decrease the hot air flow it is possibile to set the maximum speed manually using the specific parameter in menu 01 and choosing the value parameter from 1 up to 5 for example setting value parameter 3 the air fans will increase the air flow speed authomatically without exceeding the value parameter 3 you programmed before As for ducted version the electrical connection is shown through led B 4 6 2 Menu 02 set clock The electronic control device has a lithium battery mod CR2032 of 3 Volt inside It allows the internal clock to last over 4 5 years if the clock signal does not appear when the stove is off or when switching the stove again a series of 0000 appears it means it has to be substituted and you need to call one of our service point authorised for its substitution 4 6 3 Menu 03 enable chrono It allows to enable and disable all the th
100. g ausgef hrt und gem den geltenden Bestimmungen mit IN Das Netzkabel darf auf keinen Fall mit dem Abzugsrohr des Ofens in Ber hrung kommen 98 EASY CRONO HR COLA 2 7 Elektroschaltplan Netz 230V Z ndkerze W rmetauscher Abgasventilator Encoder Abgasventilator Abgasf hler Aaumt hler Thermostat ALF Haupt Sicherheitsthermostat ALC Unterdruckmesser 2 8 Notfallma nahmen Auf jeden Fall sind geeignete Brandbek mpfungsmittel bereit zu stellen Im Brandfall folgenderma en vorgehen Stromzufuhr sofort trennen Mit geeigneten Feuerl schern l schen Sofort die Feuerwehr rufen Nicht mit Wasser l schen 3 SICHERHEITSRELEVANTE HINWEISE UND VORRICHTUNGEN 3 1 Sicherheitsabstand von entflammbaren Materialien Um den Ofen herum muss ein Mindestsicherheitsabstand von entflammbaren Materialien eingehalten werden damit sich diese nicht durch berhitzung entz nden die entsprechenden Abst nde sind in der technischen Tabelle des Handbuches und auf dem Typenschild angegeben Fu boden Wenn der Fu boden aus empfindlichem und entflammbarem Material besteht sollte als Ofen Unterlage eine Platte aus Stahl oder geh rtetem Glas benutzt werden siehe Kapitel 2 Transport und Installation Zu besonders empfindlichen Einrichtungsgegenst nden wie M bel Vorh nge Sofas muss eine beachtliche Entfernung vom Ofen eingehalten werden 3 2 Sicherheitsvorrichtung Abgasf hrung Bei normalem Betrieb herrscht in der Bren
101. ggetti ritenuti particolarmente delicati quali mobili tendaggi divani aumentare considerevolmente la distanza della stufa 3 2 Sicurezza scarico fumi Nel normale funzionamento la camera di combustione in depressione garantendo la tenuta da eventuali perdite di fumo nell ambiente Nel caso in cui non si raggiunge un certo valore di vuoto o lo scarico di uscita dei fumi ostruito il vacuostato capta la mancanza di depressione all interno della camera di combustione oppure il debimetro rileva l assenza di flusso d aria comburente che tramite il controllo elettronico interrompe il funzionamento del motore rotazione coclea avvisando l utente dell anomalia con un messaggio sul pannello comandi AL 8 MANCA DEPRESS o AL 9 TIRAGGIO INSUF 3 3 Sicurezza sovrapressione in camera di combustione Eventuali e o improvvise sovrapressioni dei fumi di combustione all interno della camera e dei condotti di evacuazione dei fumi vengono scaricati attraverso l apertura delle valvole di sicurezza poste sopra lo scambiatore di calore Durante il normale funzionamento queste valvole sono chiuse dal proprio peso e dalla depressione della camera e garantiscano la tenuta contro l eventuale uscita dei fumi A Controllare periodicamente la chiusura lo stato di integrit del dispositivo e il relativo funzionamento 3 4 Surriscaldamento termostato di sicurezza temperatura serbatoio pellet Sul convogliatore del pellet posizionata una sonda d
102. gs measurements diagrams and any other configurations are given only by way of example This manual is an integral part of the product make sure it always stays with the stove even if sold transferred to another owner or installed in another place so that it can be consulted at any time If lost or damaged ask the Authorised Service Centre for a copy so that the stove always has its own manual This symbol indicates the presence of an important message failure to pay attention to it can result in serious damage to the stove and even injury Pay special attention to words in bold face 1 3 Safety rules Read the use and maintenance manual before installing lighting and servicing the stove Installation the electrical connection testing and maintenance must be carried out by a qualified and or authorised technician Connect the stove to an approved flue by means of an inspectionable terminal several units can be connected only if allowed by the local regulations and by the flue inspection Body Connect the stove to the suction system by means of a pipe or air inlet from outside Connect the stove to an approved 230 V 50 Hz electrical socket Make sure the electrical system and the sockets are suitable for the maximum absorption of the unit specified on the label and in this manual The stove must be unplugged and cold before carrying out any maintenance Do not use flammable liquids or substances to light t
103. haulichung und sind nicht verbindlich Diese Betriebsanleitung ist ein wesentlicher Bestandteil des Produkts sie muss immer beim Ger t bleiben und diesem bei Verkauf Ubereignung oder Standortverlegung folgen damit jederzeit darin nachgeschlagen werden kann Bei Verlust oder Besch digung ist beim Vertragskundendienst eine Kopie anzufordern damit das Ger t stets mit einer Betriebsanleitung ausgestattet ist Dieses Symbol weist auf eine wichtige Mitteilung hin die besondere Aufmerksamkeit erfordert denn die Nichtbeachtung der Angaben kann ernsthafte Sach und Personensch den zur Folge haben Angaben die besondere Aufmerksamkeit erfordern sind fett gedruckt 1 Sicherheitsvorschriften Vor Installation Benutzung oder Wartung des Pelletofens die Bedienungs und Wartungsanleitung lesen Die Installation den elektrischen Anschluss die Abnahme und Wartung nur von autorisiertem Fachpersonal ausf hren lassen Den Ofen ber ein inspizierbares Endst ck an ein vorschriftsm iges Schornsteinrohr anschlie en der Anschluss mehrerer Ger te ist nur zul ssig wenn er von den rtlichen Bestimmungen vorgesehen ist und vom Schornsteinfeger genehmigt wurde Den Ofen ber ein Rohr bzw einen Au enlufteinlass an den Saugzug anschlie en Den Ofen an eine vorschriftsm ige Steckdose mit Spannungswerten 230 V 50 Hz anschlie en Die elektrische Anlage und die Steckdosen m ssen f r die maximale Stromaufnahme d
104. he stove or rekindle the flame when the stove is lit pellet ignition is automatic The pellet stove must only be fed with wood pellets having the characteristics described in this manual The stove must not be used as an incinerator Never block the combustion air inlet and fume outlet openings Do not handle easily flammable or explosive substances near the stove while it is operating Do not remove or modify the pellet hopper protection grille or the safety devices Do not operate the stove with the fire door open and or the glass damaged or broken During operation the intense heat generated by combustion of the pellets makes the external surfaces of the stove very hot and in particular the fire door handle and flue pipe Therefore avoid contact with these parts without suitable protection Keep objects that are flammable and or not heat resistant at a suitably safe distance Clean the brazier regularly every time the stove is lit or whenever reloading pellets Have the duct and smoke baffles inside the combustion chamber cleaned regularly by qualified personnel Avoid the creation of smoke and unburnt products during lighting and or normal operation an excessive accumulation of unburnt pellets in the brazier must be eliminated manually before carrying out relighting Warn children and guests about the hazards described above Incase of operating problems the stove can be relit only after eliminating the cause of the pro
105. i Js J LI delle 4 programmazioni CH ARE Il programmatore settimanale pu essere attivato o disattivato inoltre impostando OFF nel campo orari l orologio ignora il PROG comando corrispondente Effettuare la programmazione con attenzione evitando di Finestra ti gialaga A far sovrapporre le ore di attivazione e o disattivazione nello stesso giorno in differenti programmi PROGRAMMA I selezione significato valori possibili livello di menu 03 03 02 03 03 07 03 03 08 03 03 09 GIOVEDI PROG 1 VENERDI PROG 1 SABATO PROG 1 DOMENICA PROG 1 03 03 03 STOP PROG 1 ora di disattivazione ora OFF 03 03 05 MARTEDI PROG 1 on off on off on off on off on off PROGRAMMA 2 giorno di riferimento START PROG 2 ora di attivazione ora OFF STOP PROG 2 ora di disattivazione ora OFF call cl 03 03 18 SABATO PROG 2 S onoff cal PROGRAMMA 3 ora di attivazione ora OFF 03 03 21 STOP PROG 3 ora di disattivazione ora OFF 03 03 22 LUNEDI PROG 3 on off 03 03 23 MARTEDI PROG 3 2 on off 03 03 24 MERCOLEDI PROG 3 on off 03 03 25 GIOVEDI PROG 3 on off 03 03 26 VENERDI PROG 3 on off 03 03 27 SABATO PROG 3 3 on off 03 03 28 DOMENICA PROG 3 on off PROGRAMMA 4 livello di menu selezione significato valori possibili 03 03 29 START PROG4 ora di attivazione ora OFF 03 03 30 STOP PROG 4 o
106. i temperatura collegata ad un termostato di sicurezza che in caso di eccessivo riscaldamento gt 85 disattiva automaticamente l alimentazione del pellet In tal caso l estrattore e o ventilatori continuano a funzionare consentendo il rapido raffreddamento dell apparecchio L anomalia viene visualizzato sul pannello comandi con il messaggio AL 7 SICUREZ TERMICA In caso di intervento operare come segue Lasciare raffreddare la stufa per almeno 45 minuti Ripristinare il termostato premendo il pulsante vicino all interruttore dietro la stufa svitando precedentemente il coperchietto di protezione figura a lato Riavviare la stufa come da normale avvio 3 5 Sicurezza contro il ritorno di fiamma sul canale alimentazione pellet Le soluzioni che impediscono il ritorno di fiamma sono gt depressione in camera di combustione ved par 3 2 gt la forma a sifone del canale di alimentazione pellet gt la sicurezza sulla temperatura del serbatoio ved par 3 4 3 6 Dispositivo elettrico di protezione dalla sovracorrente L apparecchio protetto contro la sovracorrente da fusibile i da 2A inseriti sull alimentazione dell interruttore generale della stufa dislocato posteriormente 12 EASY CRONO HR COLA 3 7 Sicurezza da interruzione di alimentazione elettrica Per brevi interruzioni di corrente l apparecchio si riaccende automaticamente La mancanza temporanea dell alimentazione elettrica non limita la s
107. icurezza della stufa e la temperatura del serbatoio non raggiunge valori elevati lt 85 vis te la modesta quantit di pellet in combustione nel braciere Tale anomalia pu creare una breve fuori uscita di fumi nell ambiente che non comporta alcun pericolo per la sicurezza A E vietato manomettere i dispositivi di sicurezza 3 8 Guasto ventilatore estrazione fumi Se per qualsiasi motivo il ventilatore di estrazione fumi si ferma il controllo elettronico blocca istantaneamente la fornitura di pellet visualizzando il messaggio AL 4 ASPIRAT GUASTO 4 USO DELLA STUFA 4 1 Premessa La stufa a pellet presenta il vantaggio di unire il calore della fiamma del legno alla comodit della gestione automatica della temperatura con la possibilit di programmare settimanalmente l accensione e lo spegnimento E possibile eseguire il collegamento ad un termostato e o cronotermostato esterno per la rilevazione della temperatura in un punto diverso da quello in cui collocata la stufa Per un utilizzo sicuro e affidabile consigliato osservare le seguenti prescrizioni con la prima messa in funzione si possono riscontrare cattivi odori pertanto si deve provvedere ad una buona aerazione della stanza soprattutto durante il primo periodo di funzionamento il caricamento del serbatoio deve essere fatto esclusivamente con pellet durante tale operazione evitare che il sacco venga a contatto con le superfici calde della stufa no
108. ieb Das vorschriftsm ig installierte Ger t funktioniert unter jeder klimatischen Bedingung bei kritischen Witterungsverh ltnissen starker Wind Frost usw k nnen allerdings die Sicherheitssysteme ausgel st werden die den Ofen ausschalten Struktur Stahl Gusseisen und Majolika Brennkammer Stahl und Gusseisen Nennw rmeleistung reduzierte W rmeleistung Pnom 9 29 kW P rid 2 58 kW Consumo orario combustibile P nom P rid Pnom 2 2 kg Std h Pred 0 57 kg h Rendimento termico P nom P rid Pnom 89 26 Pred 95 66 Rauchabzugstemperatur Nennleist red Leist Pnom 182 2 Pred 80 2 CO Emissionen mit 13 O2 Pnom 0 01 Pred 0 02 Abgasstrom Pnom 6 5 g s Pred 2 2 g s Emissioni polveri P nom 6 1 mg m Mindestschornsteinzug 10 14 Pa Rauchabzugsrohr 80 mm Lufteinlassrohr 50 mm Elektrische Versorgung 230 V 50 Hz Stromaufnahme 420 W max in fase di accensione 120 W per il normale funzionamento Distanza min sicurezza posteriore lato dx sx pavimento 200 300 0mm Abmessungen mm H x L x P 990 x 582 x 499 mm Gewicht des Ofens 98 kg Fassungsverm gen Pelletsbeh lter Litri 31 22kg Max heizbares Raumvolumen 212 m Der Verbrauch kann in Abh ngigkeit von Pelletart und Aufbewahrung unterschiedlich sein Unter Ber cksichtigung von 35 W h pro m Der Energiebedarf des Geb udes kann je nach Isolierung G
109. iften ist unbedingt vom Installationstechniker zu pr fen Es m ssen zertifizierte Rohre und Anschl sse mit angemessenen Dichtungen verwendet werden Im Brandfall den Ofen ausschalten sofort die Feuerwehr rufen und keine weiteren L schversuche unternehmen Die Rauchgasableitung und das entsprechende Rauchrohr mindestens einmal j hrlich reinigen N Die Funktionst chtigkeit und der einwandfreie Zustand des Schornsteinrohrs sowie dessen 2 4 1 Installationsarten Nachstehend werden die Vorgaben und Anforderungen aufgef hrt die f r die korrekte Installation eines Rauchabzugs gem der italienischen Norm UNI 10683 erf llt werden m ssen SCHORNSTEIN Aufw rtsf hrende bauliche Vorrichtung zum Sammeln Sad und zur Abf hrung der Verbrennungsprodukte einer bzw in den zul ssigen F llen mehrerer Feuerst tten in einer angemessenen H he vom Boden Technische Anforderungen des SCHORNSTEINS abgasdicht mit vom Windschutz Einsatz abh ngiger Isolierung und W rmed mmung Schornsteinkopf Be Phy berwiegend senkrechter Verlauf mit Achsabweichungen lt 453 ET ausreichender Abstand von entflammbarem Material mit Luftspalt oder sre TT isolierendem Zwischenraum vorzugsweise mit rundem konstantem freiem und unabh ngigem Querschnitt der Schornstein sollte eine inspizierbare Kammer zum Auffangen fester Stoffe und eventuell sich bildendem Kondensat besitzen die unter dem Eingang des Abgaskanals angebr
110. inside of the pellet hopper door or on the back of the stove It gives the following data gt Model Electrical power input gt Serial number gt Flue pipe size Type of fuel gt Inlet pipe size gt Nominal and reduced heat output gt Flue draught gt Consumption at nominal output and reduced output Stove external dimensions gt Fume temperature at nominal output and reduced Safety distance from flammable materials output gt Thermal efficiency gt Weight gt Power supply voltage 1 9 Stove decommissioning When definitively deciding to not to use the stove any more we recommend to disconnect the power supply and to empty the pallet tank completely In order to eliminate the stove it is necessary to packaged it with a strong packaging and then take contact with local organisation which follows the selling off operations respecting the local rules Otherwise we recommend to back the stove directly to the distributor when buying a similar new one On the basis of Article 13 by Legislative Decree n 151 of 25th July 2005 actuation of the European Directive 2002 96 CE of 23rd February 2003 on waste electrical and electronic equipment It is connected to the policy and action which aim to the prevention of waste electrical and electronic equipment named RAEE and in addition the reuse recycling and other forms of recovery of such wastes so as to reduce the disposal of waste It also seeks to improve the environmental perfo
111. ionnement du po le cran LCD r tro clair EASY CRONO HR Indicateurs d tat R cepteur IR 71 COLA Le tableau permet l allumage et l extinction la marche l arr t du po le la r gulation pendant le fonctionnement et le param trage des programmes de gestion et d entretien Sur l cran sont affich es toutes les informations sur l tat de fonctionnement du po le Pour acc der au menu appuyer sur la touche CONSIGNE SET P3 appuyer plusieurs fois sur les touches P5 P6 pour d rouler les menus appuyer sur une des touches d augmentation diminution P1 P2 pour ajuster le param tre d sir appuyer sur la touche CONSIGNE SET P3 pour confirmer la valeur du param tre Une fois rentr dans le menu il est possible d obtenir les diff rentes options de visualisation et d effectuer les param trages et ou r glages disponibles suivant le niveau d acc s Le tableau ci apr s indique les commandes et des messages correspondants affich s pendant la phase de programmation ou pr s lection des param tres de fonctionnement Bouton Description Modalit Action Augmentation PROGRAMMATION Modifie augmente la valeur de menu s lectionn e 1 de la FONCTIONNEMENT e OFF Augmente la valeur de la temp rature du thermostat d ambiance temp rature PROGRAMMATION Modifie diminue la valeur de menu s lectionn Diminution de 2 la temp rature FON
112. ique 63 EASY CRONO HR COLA 499 990 E wo D D Baooaanaaaaa B L gende Dimensions du po le a granul s EASY CRONO HR A Grilles de passage d air B Connexion du cable lectrique C Aspiration d air comburant diam 50 mm D Raccordement tuyau d vacuation des fum es diam 80 mm E Couvercle de r servoir granul s 64 EASY CRONO HR COLA Pour ouvrir la porte ins rer la poign e fournie et tourner en sens Poign e d ouverture fermeture horaire porte de foyer Ouverture sens horaire Fermeture sens anti horaire 1 5 Combustible et usage pr vu Les po les granul s fonctionnent exclusivement avec des granul s pastilles d essences de bois diff rentes conform ment la norme DIN plus 51731 ou UNI EN14961 2 ou O Norm M 7135 ayant les caract ristiques suivantes Pouvoir calorifique min 4 8 kWh kg 4180 kcal kg Densit 680 720 kg m3 Humidit max 10 de son poids Diam tre 6 0 5 mm Taux de cendres max 1 5 de son poids Longueur min 6 mm max 30 mm Composition 100 bois non trait de l industrie du bois ou post consommation sans adjonction de substances liantes et sans corce conforme aux normes en vigueur Conditionnement dans des sacs en mat riau compatible avec l environnement ou biod gradable ou en papier Le r servoir granul s se trouve a l arriere du po
113. iques mod les avec habillage c ramique Les carreaux c ramiques COLA sont fabriqu s de mani re artisanale et peuvent ce titre pr senter de petites imperfections superficielles telles que micro pig res ou variations chromatiques Il est conseill de les nettoyer avec un chiffon doux et sec l utilisation de certains d tergents pourrait mettre davantage en vidence les imperfections 5 7 Nettoyage du conduit de raccordement conduit de fum e Le conduit de raccordement doit tre nettoy au moins une fois par an ou toutes les fois que cela est n cessaire en fonction de l utilisation du po le et du type d installation Le nettoyage comprend l aspiration et l limination de r sidus de combustion dans tous les tron ons verticaux et horizontaux ainsi que dans les coudes de l appareil au conduit de fum e Il est galement conseill de nettoyer le conduit de fum e une fois par an afin de garantir une parfaite vacuation des fum es de faire appel un centre d assistance agr qui v rifiera par la m me occasion l tat d usure des Pour toutes les op rations d entretien ou de nettoyage de fin de saison la soci t COLA recommande A composants internes du po le 82 EASY CRONO HR COLA 6 ENTRETIEN 6 1 Introduction Les interventions sur les composants du po le doivent tre effectu es par un professionnel qualifi en s adressant au centre d assistance le plus proche A Avant toute intervention s assu
114. isiti tecnici COMIGNOLO avere sezione equivalente a quella del camino avere sezione utile non minore del doppio di quella interna del camino deve impedire la penetrazione di pioggia e di corpi estranei ed in ogni condizione atmosferica assicurare lo scarico dei prodotti di combustione deve garantire un adeguata diluizione dei prodotti ed essere posizionato al di fuori della zona di reflusso deve essere privo di mezzi meccanici di aspirazione Lo scarico diretto dei prodotti della combustione deve essere previsto a tetto ed vietato verso spazi chiusi anche a cielo libero 2 5 Controllo posizione braciere e deviatore Prima di accendere la stufa importante controllare che il braciere sia in posizione corretta ovvero alloggi negli appositi incastri Inoltre controllare che il deviatore fumi superiore sia incastrato nella propria sede Una posizione errata del deviatore comporta malfunzionamenti ed un eccessivo annerimento del vetro A Ad ogni accensione dell apparecchio controllare la corretta posizione del braciere sul relativo porta braciere 2 6 Collegamento elettrico Collegare il cavo di alimentazione elettrica da una parte alla presa posteriore della stufa e dall altra su una presa elettrica a parete La tensione fornita dall impianto deve corrispondere a quella indicata sulla targhetta di identificazione della stufa e nel paragrafo relativo ai dati tecnici di questo manuale Nel periodo di inutilizzo d
115. ithout bumping and position it in the required place Make sure the floor can take the weight of the stove otherwise consult a specialised technician Disposal or recycling of the packing must be carried out by the end user in compliance with the current local regulations 2 2 Place of installation positioning and fire prevention safety The place of installation must be sufficiently ventilated to allow the removal of any combustion smoke leaks The unit is suitable for operation in domestic environments with min temperature not below 00 To prevent the risk of fire the structures surrounding the stove must be protected from the heat Floors in wood or in any flammable material must be suitably protected at the base with steel or toughened glass panels the protection must cover the base and also a certain area in front of the stove Any wooden boards or beams above or crossed by the flue must be suitably protected in conformity with the requirements of the specific current installation standards The minimum front distance for the protection of flammable objects is 1 5 m The minimum safety distances from flammable materials must comply with the following table A 300 mm B 200 mm C 1500 mm D 200 mm al ________ _f___ 777 if Na WW NY 38 EASY CRONO HR COLA Every installation must provide for an easily accessible technical space for periodical maintenance The stove is provided with
116. l Norme CEI EN 62233 M thodes de mesure des champs lectromagn tiques des appareils lectrodomestiques et similaires en relation avec l exposition humaine Normes DIN plus 51731 UNI EN14961 2 Norm M 7135 Normes relatives aux sp cifications et la classification des granul s de bois 1 8 Plaque d identification La plaque d identification est fix e sur la face int rieure du couvercle du r servoir granul s ou l arri re du po le La plaque porte les indications suivantes Mod le Num ro de fabrication Type de combustible Puissance thermique nominale r duite Consommation la Pnom et Pr d Temp rature la Pnom et Pr d Rendement thermique Tension d alimentation Consommation lectrique Dimension du tuyau d vacuation des gaz Dimensions du tuyau d aspiration Tirage du conduit de fum e Dimensions hors tout du po le Distance de s curit par rapport aux mat riaux inflammables Poids vv vvv v v vvv vvv v v 1 9 Mise hors service du po le A partir du moment o le po le n est d finitivement plus utilis d brancher l alimentation lectrique et vider compl tement le r servoir granul s Pour proc der l vacuation du po le il est n cessaire de pr voir un emballage solide et adapt Il faut ensuite contacter les organismes locaux afin de connaitre les r gles et normes en vigueurs pour l vacuation du mat riel ou restituer au revendeur du nouveau produit similaire l a
117. l suo interno ed eventuali residui di combustione Dopo la pulizia necessario chiudere lo sportello La pulizia del contenitore cenere pu essere eseguita ogni 2 3 giorni in funzione dell utilizzo della stufa 5 3 Pulizia del vetro e delle fessure circolazione aria La pulizia del vetro pu essere effettuata con un panno umido utilizzando detergenti specifici non abrasivi Tra vetro ferma vetri e porta fuoco sulla parte inferiore e superiore sono state realizzate apposite fessure per la circolazione dell aria e la pulizia interna del vetro E importante mantenere pulite tali fessure da eventuali depositi di cenere e polvere Eseguire quindi periodicamente una pulizia lungo tutto il contorno interno del vetro 5 4 Pulizia estrattore fumi e della camera di combustione Almeno una volta all anno si deve procedere alla pulizia della camera di combustione rimovendo tutti i residui di combustione dai deviatori interni e dal percorso fumi Per eseguire tale operazione necessario rimuovere il coperchio ed il frontalino superiore della stufa Rimuovere lo scambiatore in ghisa svitando le viti che lo fissano e procedere quindi alla pulizia dei deviatori e della camera Inoltre importante pulire l estrattore fumi che si trova sotto la camera al quale si accede togliendo lo sportello d ispezione frontale collocato sulla parte inferiore della camera Ogni 3 4 mesi pulire le pareti interne isolanti refrattari della camera di combustio
118. le Le couvercle du r servoir est plac dans la partie sup rieure du po le et le chargement se fait manuellement uniquement po le teint en faisant attention ne pas faire sortir le sac de granul s L utilisation de granul s de bois ayant des caract ristiques diff rentes de celles des granul s utilis s pour le test lors du premier allumage implique un nouvel ajustement des param tres de chargement des granul s dans le po le Noter que cette intervention n est pas couverte par la garantie Les granul s doivent tre stock s dans un lieu sec et prot g contre l humidit En vue d un fonctionnement efficace et r gulier du po le il n est pas possible de charger A manuellement les granul s ou d autres combustibles dans le foyer Eviter le chargement de combustibles non conformes dans le r servoir Eviter le chargement de corps trangers tels que r cipients bo tes sachets m taux etc dans le r servoir L utilisation de granul s de qualit m diocre et non conforme d t riore et compromet le bon fonctionnement du po le ce qui entra ne l annulation de la garantie et d gage le constructeur de toute responsabilit 1 6 Accessoires fournis La fourniture comprend c ble d alimentation lectrique manuel d installation utilisation et entretien cl d ouverture de fermeture porte de foyer 65 EASY CRONO HR COLA 1 7 Normes de r f rence Norme UNI 10683 2005 elle fixe les exigences es
119. lection les fonctions du menu ne varient pas et la signalisation du raccordement se fait par l allumage de la LED segment sur la barre d tat l cran 80 EASY CRONO HR COLA 4 9 P riode d inactivit fin de saison Si le po le est destin rester inutilis pour de longues p riodes et ou la fin de chaque saison il est conseill de proc der comme suit vider compl tement le r servoir granul s couper l alimentation lectrique du po le nettoyer parfaitement et si n cessaire remplacer les parties ventuellement endommag es par un professionnel qualifi prot ger le po le contre la poussi re avec une b che ou housse ou tout autre dispositif d une efficacit au moins quivalente stocker le po le dans un endroit sec et l abri des intemp ries 5 NETTOYAGE DU POELE Il est important de nettoyer le po le pour viter le noircissement de la vitre de foyer la mauvaise combustion le d p t de cendres et d imbr l s dans le foyer et la r duction de l efficacit thermique La porte du foyer doit toujours tre ferm e quand le po le est allum Les joints des portes de foyer et du cendrier doivent tre contr l es r guli rement pour viter toute infiltration d air en effet la chambre de combustion et le canal d vacuation des granul s fonctionnent en d pression tandis que les fum es sont vacu es en l g re pression Les op rations de nettoyage courant doivent tr
120. led For safe and reliable use when lighting and using the stove the first time unpleasant odours may be created therefore air the room thoroughly the hopper must only be filled with pellets make sure the bag does not come into contact with the hot surfaces of the stove do not put any fuel other than the prescribed pellets in the hopper the stove must not be used as a waste incinerator the stove must only operate with the fire door always closed the fire door seals must be checked periodically to prevent air from entering to guarantee efficient performance and correct operation it is necessary to carry out periodical cleaning of the brazier every time pellets are loaded when lighting the stove for the first time allow it to heat up gradually by setting low operating temperatures see section on temperature setting during lighting operation and shutdown the stove may creak a little due to the heat expansion 4 2 Description of control panel The control panel comprises a backlit LCD on off button P4 SET MENU button P3 four menu buttons P1 P2 P5 P6 and seven stove operation status LEDs Status indicators IR receiver Backlit LCD 42 EASY CRONO HR COLA The panel enables stove lighting and shutdown adjustment during operation and the setting of management and maintenance programmes The display shows all the information on stove operation status To access the m
121. llen und vom Men 03 01 die Uhrenthermostat Funktionen deaktivieren Bei jeder Einstellung ndern sich die anderen Funktionen des Men s nicht und die Anzeige des Anschlusses erfolgt durch Aufleuchten der LED Segmentanzeige an der Statusleiste auf dem Display 110 EASY CRONO HR COLA 4 9 AuBerbetriebnahme Ende der Heizperiode Wird der Ofen f r l ngere Zeit nicht benutzt folgenderma en vorgehen Den Pelletbeh lter vollst ndig ausleeren Die Stromzufuhr trennen und das Kabel vom Schalter entfernen Gr ndlich s ubern und bei Bedarf alle besch digten Teile von Fachpersonal ersetzen lassen Den Ofen abdecken um ihn vor Staub zu sch tzen An einem trockenen witterungsgesch tzten Ort unterstellen 5 REINIGUNG DES OFENS Der Ofen muss unbedingt regelm ig gereinigt werden um einen korrekten Betrieb zu garantieren und zu vermeiden dass das Glas verru t eine schlechte Verbrennung auftreten kann sich Asche und unverbrannte Teile im Brenntopf ansammeln die Heizleistung abnimmt Der Ofen darf nur mit geschlossener Feuerraumt r betrieben werden Die Dichtungen der Feuerraumt r sind regelm ig zu pr fen um das Eindringen von Luft zu vermeiden die Brennkammer und die Pelletrohrleitung arbeiten n mlich mit Unterdruck der Rauchabzug dagegen mit leichtem Druck Die ordentliche Reinigung wird normalerweise vom Kunden unter Befolgung der im Benutzerhandbuch enthaltenen Anleitungen vorgenommen w hrend die a
122. llo di comando e consente l accensione spegnimento della stufa la regolazione della potenza e la temperatura che si desidera avere Essendo un dispositivo che trasmette tramite un diodo ad infrarosso necessario il puntamento verso l unit ricevente inserita nel pannello di comando Il telecomando consente le seguenti operazioni pe nn LA D L Led acceso con la pressione di qualsiasi tasto IN 7 mc e Tasto P1 P6 Accensione spegnimento stufa 15 I i t An ur Tasto P1 Aumento temperatura ambiente Tasto P6 Aumento livello di potenza Tasto P5 Diminuzione livello di potenza Tasto P2 Diminuzione temperatura ambiente 4 7 1 Sostituzione batteria Il telecomando viene fornito senza la batterie di alimentazione esso funziona con una batteria posta nella parte inferiore del dispositivo e per il suo inserimento ed eventuale sostituzione necessario procedere nel modo seguente Aprire il coperchio posto nella parte posteriore del telecomando Sostituire la batteria modello p23ga da 12V nella sede rispettando la polarit Chiudere il telecomando Controllare il regolare funzionamento La batteria del telecomando deve essere sostituita e smaltita in modo N Tenere il telecomando lontano da fonti di calore dirette e dall acqua sicuro rispettando le norme locali 4 8 Termostato cronotermostato esterno L apparecchio di serie controlla la temperatura ambiente t
123. ltre operazioni di ripristino PELLET ellet devono essere condotto da P f un centro di assistenza Il termostato di sicurezza ha Avviene nel caso di intervento nevat una temperatura Verificare la causa dello AL7 i superiore alla soglia di del termostato di sicurezza taraua berin eccessivo surriscaldamento SICUREZ della temperatura canale wap Sbloccare il termostato di surriscaldamento della parte TERMICA coclea interiore delserbatoio sicurezza agendo sul pulsante Il sistema viene arrestato i di ripristino bloccando il funzionamento del motoriduttore 29 EASY CRONO HR COLA Segnalazione Anomalia Cause possibili Rimedi Verificare la pulizia del A condotto fumario e della La camera di combustione l camera di combustione In fase di lavoro la stufa rileva sporca NVetificare la chiusura AL 8 una pressione inferiore alla Il condotto fumi ostruito Hoi della borta MANCA soglia di taratura del La porta fuoco non chiusa Ne tificare la an delle DEPRESS vacuostato Le valvole antiscoppio sono alvals antisboppin Il sistema viene arrestato aperte inceppate Al SPP di CREDI Il vacuostato difettoso SO Pen OLD i devono essere condotte da un centro di assistenza Verificare la pulizia del condotto fumario e della La camera di combustione sporca camera di combustione AL 9 Compare quando il flusso Il condotto fumi ostruito ii on FASSA T
124. m e pour l vacuation des produits de combustion Prescriptions techniques du CARNEAU il ne doit pas traverser des locaux o l installation d appareils de combustion est interdite Conduit de raccordement Chambre inspectionnable 7 Prise d air ext rieur min 100 cm2 Distance minimale 0 2 m 68 EASY CRONO HR COLA l usage de conduits m talliques flexibles ou en fibrociment est interdit l utilisation d l ment a contre pente est interdite le s trongon s horizontal aux du conduit doit doivent avoir une pente minimale de 3 vers le haut la longueur du trongon ne doit pas d passer 3 m minimum le nombre de d voiements admis sans raccord en T ne doit pas tre sup rieur a 3 en cas de d voiement gt 90 pr voir le montage de 2 coudes maximum d une allure horizontale ne d passant pas 2m le conduit de raccordement doit avoir une section uniforme sur toute la longueur et permettre de r cup rer la suie SOUCHE DE CHEMINEE appel e aussi SORTIE DE TOIT l ment plac au sommet du conduit de fum e ou de chemin e sa partie ext rieure servant vacuer dans l atmosph re les produits de combustion Prescriptions techniques de la SOUCHE DE CHEMINEE elle doit avoir une section quivalente celle du conduit de fum e elle doit avoir une section utile non inf rieure au double de la section int rieure du conduit de fum e elle doit emp cher la
125. manutenzione Sul display sono visualizzate tutte le informazioni sullo stato di funzionamento della stufa Per accedere ai menu procedere come segue premere il tasto SET P3 premere i tasti P5 Pe per scorrere i vari men premere su uno dei tasti di incremento decremeto P1 P2 per settare il parametro desiderato premere il tasto SET P3 per confermare il valore del parametro Accedendo al menu possibile ottenere i vari tipi di visualizzazione ed effettuare le impostazioni disponibili a seconda del livello di accesso Di seguito riportata la tabella dei comandi e dei relativi messaggi visualizzati in fase di programmazione o impostazione dei parametri operativi azione pulsante descrizione modalit PROGRAMMAZIONE Modifica incrementa l valore di menu selezionato Incrementa temperatura B LAVORO SPENTO ae ni il valore della temperatura del termostato am PROGRAMMAZIONE Modifica decrementa il valore di menu selezionato Decrementa temperatura LAVORO SPENTO ze l valore della temperatura del termostato Accede al MENU Menu MENU Accede al successivo livello di sottomenu 3 PROGRAMMAZIONE Imposta valore e passa alla voce di menu successiva Premuto per 2 secondi accende o spegne la stufa se spen LAVORO P pest en ta o accesa rispettivamente BLOCCO Sblocca la stufa e la r porta nello stato spento MENU Si porta al liv
126. men 1 8 Typenschild 1 9 AuBerbetriebsetzung des Ofens 1 10 Anleitungen f r die Anforderung von Kundendiensteingriffen und Ersatzteilbestellungen 2 TRANSPORT UND INSTALLATION 2 1 Verpackung Handhabung Versand und Transport 2 2 Aufstellungsort Aufstellung und Brandschutz 2 3 Lufteinlass 2 4 Abgasf hrung 2 4 1Installationsarten 2 5 Positionskontrolle von Brenntopf und Abweise 2 6 Elektrischer Anschluss 2 7 Elektroschaltplan 2 8 NotfallmaBnahmen 3 SICHERHEITSRELEVANTE HINWEISE UND VORRICHTUNGEN 3 1 Sicherheitsabstand von entflammbaren Materialien 3 2 Sicherheitsvorrichtung Abgasf hrung 3 3 Uberdruckventil in der Verbrennungskammer 3 4 berhitzung Sicherheitsthermostat Temperatur Pelletsbeh lter 3 5 Flammenr ckschlagschutz im Pelletzuf hrungskanal 3 6 berstromsicherung 3 7 Stromausfallsicherung 3 8 Defekt des Abgasventilators 4 GEBRAUCH DES OFENS 4 1 Vorwort 4 2 Beschreibung des Bedienpanels 4 3 Einschalten 4 3 1 Kontrolle vor Inbetriebnahme 4 3 2 Z ndvorgang 4 4 Betriebsphase 4 5 Ausschalten 4 6 Men 4 6 1 Men 01 L fter regeln 4 6 2 Men 02 Uhr einstellen 4 6 3 Men 03 Uhrenthermostat aktivieren 4 6 4 Men 04 Sprache w hlen 4 6 5 Men 05 Standbybetrieb 4 6 6 Men 06 Summer 4 6 7 Men 07 Erste Pelletf llung 4 6 8 Men 08 Betriebszustand des Ofens 4 6 9 Men 09 Vom Techniker vorgenommene Einstellungen 90 COLA 4 7 Fernbedienung
127. ment la pi ce pendant la premi re p riode de fonctionnement le remplissage du r servoir doit se faire exclusivement avec des granul s Pendant cette op ration viter que le sac entre en contact avec les surfaces chaudes du po le ne pas introduire dans le r servoir d autres types de combustible que les granul s conformes aux prescriptions ne pas utiliser le po le comme incin rateur de d chets la porte du foyer doit toujours tre ferm e quand le po le est allum les joints de la porte du foyer doivent tre contr l s r guli rement pour viter toute infiltration d air le po le doit toujours tre propre pour garantir un bon fonctionnement et un rendement thermique efficace nettoyer le brasier chaque chargement de granul s il est important au premier allumage de ne pas surchauffer le po le mais de le faire monter progressivement en temp rature en programmant des temp ratures de fonctionnement basses voir paragraphe programmation des temp ratures pendant l allumage le fonctionnement et l extinction le po le peut mettre des cliquetis cause de la dilatation thermique 4 2 Description du tableau de commande Le tableau de commande comprend un cran LCD r tro clair une touche d allumage extinction marche arr t P4 une touche de fonction SET MENU P3 quatre touches de menu P1 P2 P5 Pe et 7 LED de signalisation de l tat de fonct
128. mento del cavo elettrico e la commutazione in ON 1 dell interruttore collocato posteriormente alla stufa potrebbero bruciare istruzioni etichetta Eventuali accensioni eseguite a seguito di lunghe inattivit dell apparecchio richiedono il ripristino di eventuali resti di pellet giacenti da tempo all interno del serbatoio in quanto combustibile umido non pi idoneo alla combustione e una pulizia completa della camera di combustione i Alla prima messa in funzione togliere dal focolare della stufa e del vetro tutti i componenti che 4 3 2 Fase di avvio Per accendere la stufa premere il pulsante P4 per 3 secondi sul display comparir la scritta START Questa fase automatica ed completamente gestita da controllo elettronico senza alcuna possibilit di intervenire sui parametri Temperatura ambiente Pulsante P4 La stufa esegue in sequenza le fasi di avvio secondo le modalit definite dai parametri che ne gestiscono livelli e tempistica raggiungendo la condizione di lavoro a meno che non insorgono anomalie o allarmi secondo il prospetto seguente stato durata dispositivi condizioni per passaggio a stato successivo accenditore asp fumi coclea scamb SPENTO OFF START PULIZIA IN Pr33 OFF decorso tempo Pr33 PRERISCALDO ON OFF OFF decorso tempo Pr34 PRECARICA PELLET Pr40 ON decorso tempo Pr40 ATTESA FIAMMA P 41 ON CARICA PELLET ON temperatura fumi gt Pr13 FUOCO PRESE
129. modo da ridurne la quantit da avviare allo smaltimento e migliorando l intervento dei soggetti che partecipano al ciclo di vita di tali prodotti Il simbolo del cassonetto barrato riportato sull etichetta dell apparecchiatura indica che il prodotto alla fine della propria vita utile deve essere raccolto separatamente da altri rifiuti 1 10 Istruzioni per richiesta di intervento e ricambi Per richiedere qualsiasi intervento e o ricambio contattare il proprio rivenditore importatore di zona o il centro di assistenza autorizzato pi vicino esponendo in modo chiaro i seguenti dati modello della stufa numero di serie data di acquisto lista dei ricambi e informazioni sulle anomalie o malfunzionamenti riscontrati Prima di ogni intervento accertarsi che sia disinserito ogni collegamento elettrico e che la stufa sia fredda Utilizzare solo ricambi originali 2 TRASPORTO ED INSTALLAZIONE N Gli interventi sui componenti devono essere effettuati da personale autorizzato e o qualificato 2 1 Imballo movimentazione spedizione e trasporto Il sollevamento della stufa completa di imballo pu essere effettuato mediante carrello elevatore inserendo le forche di adeguata lunghezza nelle apposite sedi del bancale in legno E necessario accertarsi che i dispositivi utilizzati per il sollevamento e il trasporto siano in grado di sopportare il peso della stufa indicato sulla targhetta di identificazione e sul presente manuale 8 EAS
130. n Manifold fume extractor n n Glass door seal Pipe flue connection n 5 1 Cleaning the brazier Remove the brazier and the ash deposited in the combustion chamber and brazier holder A suitable vacuum cleaner may be used for this purpose This operation must be carried out daily especially in case of accumulated unburnt matter to ensure perfect combustion conditions since the brazier holes allow the flow of combustion air The brazier must rest on the brazier holder and precisely on the entire ring band without air gaps Brazier dirty Brazier clean Brazier Holder clean 52 EASY CRONO HR COLA 5 2 Cleaning the ash container The ash container is located directly under the brazier brazier holder To clean it open the fire door and remove the ash and any combustion residuals using a suitable vacuum cleaner The door must be closed after cleaning The ash container can be cleaned every 2 3 days depending on stove use 5 3 Cleaning the glass and air slots The glass can be cleaned using a damp cloth and specific non abrasive detergents Special slots between the glass glass stops and fire door at the top and bottom allow air to circulate on the inside surface of the glass These slots must be kept clean of any deposits of ash and dust Therefore periodically clean all around the the inner side of the glass 5 4 Cleaning the fume extractor and combustion chamber The combustion chamber must
131. n Reinigungsmitteln k nnten eventuelle Fehler betont werden 5 7 Reinigung des Rauchrohrs Schornsteinrohrs Das Rauchrohr muss mindestens einmal j hrlich oder bei Bedarf je nach Gebrauch und Installationsart des Ofens Die Reinigung umfasst das Absaugen und Entfernen der R ckst nde in allen senkrechten und waagerechten Rohrabschnitten sowie in den Rohrkr mmern vom Ger t zum Schornsteinrohr Einmal im Jahr sollte auch das Schornsteinrohr gereinigt werden um eine korrekte und sichere Rauchabf hrung sicherzustellen i F r jede Art von Wartung und f r die Reinigung am Ende der Heizperiode empfiehlt die Firma COLA sich an den Vertragskundendienst zu wenden der den Ofen nicht nur reinigt sondern auch den VerschleiBzustand der inneren Bauteile des Ofens kontrolliert 112 EASY CRONO HR COLA 6 WARTUNG 6 1 Vorwort Die Eingriffe an Innenkomponenten des Ofens m ssen von autorisiertem Fachpersonal durchgef hrt werden wenden Sie sich hierf r bitte an den n chstgelegenen Kundenservice Vor jedem Eingriff am Ofen muss sichergestellt werden dass der Netzstecker gezogen und der Ofen AN kalt ist 6 2 Ausbau der Verkleidung Zeichenerkl rung 1 Keramikabdeckung 2 Untere Frontblende aus lackiertem Stahl 3 R ckwandverkleidung 4 Schutzabdeckung des Getriebemotors 5 Seitliche Blechverkleidung rechts 6 Seitliche Blechverkleidung links 7 T r
132. n bon tat et qu il fonctionne correctement 3 4 Surchauffe thermostat de s curit temp rature r servoir granul s Une sonde de temp rature sur la paroi avant basse du r servoir au dessus du convoyeur des granul s reli e un thermostat de s curit bloque automatiquement l arriv e des granul s en cas de surchauffe gt 85 Dans ce cas l extracteur et ou les ventilateurs continuent fonctionner pour refroidir plus rapidement l appareil L anomalie est affich e sur le tableau de commande par le message AL 7 SECURITE THERMIQUE En cas d intervention proc der comme suit Laisser refroidir le po le pendant au moins 45 minutes R armer le thermostat en appuyant le bouton proche de l interrupteur derri re le po le en d vissant au pr alable le couvercle de protection figure ci contre Rallumer le po le normalement 3 5 S curit contre le retour de flamme sur le canal d alimentation en granul s Les solutions pour emp cher le retour de flamme sont d pression dans la chambre de combustion voir 3 2 gt La forme en siphon du canal d alimentation des granul s gt La s curit sur la temp rature du r servoir voir 3 4 3 6 Dispositif lectrique de protection contre les surtensions L appareil est prot g contre les surtensions par un des fusible s de 2 A sur l alimentation de l interrupteur g n rale du po le situ l arri re de celui ci 70 EASY CRONO HR C
133. n des fum es Ee est d faillant fonctionnement normal doivent tre L est d faillant dis courant blesinduentanva bas ali effectu es par un centre DEFAILLANT La proc dure d extinction est activ e qui p d assistance ventilateur des fum es Le r servoir granul s est vide a presence de granules dans AL5 j i La r sistance lectrique est rare P ALLUMAGE o petite flamme ne s allume pas en d fectueuse encrass e ou n est pas V rifier les proc dures d allumage A phase d allumage a correctement en place D autres op rations de RAT La procedure d extinction est activ e _B glage du chargement des granul s tablissement du fonctionnement on 9 9 normal doivent tre effectu es par un centre d assistance Le r servoir granul s est vide ue pr sence de granul s dans AL 6 Le fonctionnement du motor ducteur R gler l alimentation des granul s ABSENCE DE Perd n est pas aliment en eee des granul s doit se D autres op rations de GRANULES Le motor ducteur ne charge pas les r tablissement du fonctionnement ranul s normal doivent tre effectu es par un 9 i centre d assistance Cette alarine se d clenche sn cas Le thermostat de s curit a relev un AL7 d intervention d thermostat de temp rature sup rieure au seuil de V rifier la cause de l chauffement re i r glage cause de la surchauffe de la excessif SECURITE i de la temperature du canal partie inf rieure du r servoir et a
134. n inserire nel serbatoio nessun altro tipo di combustibile che non sia pellet conforme a quanto prescritto l apparecchio non deve essere utilizzato come inceneritore di rifiuti la stufa deve funzionare solo ed esclusivamente con la porta fuoco sempre chiusa le guarnizioni della porta fuoco vanno controllate periodicamente per evitare che vi siano infiltrazioni d aria per garantire un efficiente rendimento termico ed una corretta funzionalit necessario effettuare la pulizia periodica del braciere ad ogni carico pellet alla prima accensione importante non surriscaldare la stufa ma portarla gradatamente in temperatura impostando temperature di funzionamento basse vedere paragrafo impostazione temperatura la stufa durante l accensione funzionamento e spegnimento a causa delle dilatazioni termiche a cui soggetta pu generare leggeri scricchiolii 4 2 Descrizione del pannello comandi Il pannello comandi costituito da un display LCD retroilluminato dal tasto di accensione spegnimento P4 dal tasto funzione SET MENU P3 dai quattro tasti menu P1 P2 P5 P6 e da 7 led indicanti lo stato di funzionamento della stufa Segnalatori di stato Ricevitore IR Display LCD retroilluminato 13 EASY CRONO HR COLA Il pannello consente l accensione e lo spegnimento della stufa la regolazione durante il funzionamento e permette il settaggio dei programmi di gestione e
135. nahme darf der Ofen nicht berhitzt werden sondern muss allm hlich durch Einstellen niedriger Temperaturen auf Betriebstemperatur gebracht werden siehe Absatz Temperatureinstellung Aufgrund der W rmeausdehnung kann der Ofen beim Einschalten w hrend des Betriebs und beim Ausschalten leichte Ger usche von sich geben 100 EASY CRONO HR COLA 4 2 Beschreibung des Bedienpanels Das Bedienpanel besteht aus einem hinterleuchteten LCD Display der Ein Ausschalttaste P4 der Funktionstaste SET MENU P3 den vier Men tasten P1 PZ P5 Pe und 7 LEDs die den Betriebszustand des Ofens anzeigen IR Empf nger Hinterleuchtetes LCD Display Vom Bedienpanel kann der Ofen ein und ausgeschaltet der Betrieb geregelt das Regel und das Wartungsprogramm eingerichtet werden Auf dem Display werden alle Informationen ber den Betriebszustand des Ofens angezeigt Die Men s werden wie folgt aufgerufen Die Taste SET P3 dr cken mehrmals der Tasten P5 P6 dr cken um durch die verschiedenen Men s zu bl ttern eine der Tasten Erh hen Verringern P1 P2 dr cken um den gew nschten Parameter einzustellen die Taste SET P3 dr cken um den Parameterwert zu best tigen Nach ffnen des Men s k nnen die verschiedenen Anzeigearten eingerichtet und die je nach Zugriffsebene verf gbaren Einstellungen vorgenommen werden In der nachstehenden Tabelle sind die Bef
136. ne con opportune attrezzature pennelli ed eventualmente sostituirle in quanto considerate materiali di usura La stufa ogni 1800 ore di funzionamento segnala tramite un messaggio SCADENZA SERVICE la richiesta di manutenzione straordinaria non in garanzia da parte di personale qualificato il quale provvede ad una pulizia completa e al ripristino del messaggio A Eventuali urti o forzature possono danneggiare l estrattore fumi rendendolo rumoroso durante il funzionamento pertanto si consiglia di far eseguire tale operazione da personale qualificato 5 5 Pulizia debimetro All interno del tubo di aspirazione installato un debimetro misuratore del flusso d aria comburente il quale periodicamente ogni 3 4 mesi necessit di una pulizia interna con opportune attrezzature soffio d aria compressa o idonei pennelli 5 6 Pulizia delle ceramiche per modelli in ceramica Le ceramiche sono di fabbricazione artigianale e come tali possono presentare delle piccole imperfezioni superficiali sia come micro puntinature sia come disomogeneit cromatiche Per la pulizia delle ceramiche si consiglia di usare un panno morbido ed asciutto l utilizzo di eventuali detergenti potrebbe evidenziare le eventuali imperfezioni 5 7 Pulizia raccordo fumi canna fumaria Il raccordo fumi deve essere pulito minimo una volta all anno o quando se ne presenti la necessit in base all utilizzo che viene fatto della stufa e al
137. ni le misure gli schemi ed ogni altra configurazione sono qui riportati solo a scopo esemplificativo COLA S r l Viale del Lavoro 37040 Arcole VR Italy tel 045 7635780 045 6144043 Fax 045 6144048 e mail info anselmocola com on line www anselmocola com Partita IVA e Codice Fiscale 02990180230 GRUPPO Fax Amministrazione 045 7639029 Fax Commerciale 045 6144048 Fax Assistenza 045 7639030 30 EASY CRONO HR COLA 8 ALLEGATI INFORMAZIONI MARCATURA CE CE MARKING INFORMATION CE COLA 2012 EN 14785 2006 Apparecchi per il riscaldamento domestico a pellet di legno Residential space heating appliance fired by wood pellets Ref EASY CRONO HR Distanza minima di sicurezza da materiali infiammabili Dietro lato destro sinistro pavimento Minimum safety clearance distance from combustible materials rear right side left side floor 200 300 0 mm Emissioni di CO al 13 O2 nei prodotti di combustione Pnom 0 01 Emission of CO to 13 O2 in combustion products Prid 0 02 Emissioni polveri al 13 O2 nei prodotti di combustione Dust emission to 13 O2 in combustion products Pnom 6 1 mg m Massima pressione idrica di esercizio bar Maximum water operating pressure Temperatura gas di scarico Pnom 182 2 Flue gas temperature Prid 80 2 Potenza termica nominale e ridotta Pnom 9 29 kW Nominal and reduced heat output Prid 2 58 kW Ren
138. nkammer Unterdruck was das Austreten von Rauch in den Raum verhindert Nel caso in cui non si raggiunge un certo valore di vuoto o lo scarico di uscita dei fumi ostruito il vacuostato capta la mancanza di depressione all interno della camera di combustione oppure il debimetro rileva l assenza di flusso d aria comburente che tramite il controllo elettronico interrompe il funzionamento del motore rotazione coclea avvisando l utente dell anomalia con un messaggio sul pannello comandi AL 8 KEIN UNTERDRUCK o AL 9 UNGEN GENDER ZUG 3 3 Uberdruckventil in der Verbrennungskammer Eventuelle und oder pl tzliche berdr cke der Verbrennungsgase in der Kammer und in den Rauchabzugsleitungen werden durch das ffnen der Sicherheitsventile die sich am vorderen Teil der Brennkammer befinden abgelassen W hrend des normalen Betriebs sind diese Ventile durch das eigene Gewicht und den Unterdruck der Kammer geschlossen und verhindern dadurch einen eventuellen Rauchaustritt A Die Sicherheitsventile regelm ig auf ihre Funktionst chtigkeit und ihren Zustand berpr fen 99 EASY CRONO HR COLA 3 4 berhitzung Sicherheitsthermostat Temperatur Pellettank Am Pelletsf rderer befindet sich ein mit einem Sicherheitsthermostat gekoppelter Temperaturf hler der die Pelletszuf hrung bei berhitzung gt 85 automatisch unterbricht In diesem Fall laufen das Saugzuggebl se und oder die Ventilatoren weiter damit der Ofen schnell abk hlen
139. ns le champ horaires l horloge ignorera la commande correspondante Eviter de faire chevaucher les heures d activation et ou COLA 436 ee Re Sia SERRER PRUG i La programmation doit se faire avec grande attention Fen tre de dialogue de d sactivation dans le m me jour au sein de diff rents programmes PROGRAMME 1 Niveau de menu S lection Signification Valeurs possibles 03 03 02 03 03 03 STOP PROG 1 Heure de d sactivation ora OFF 03 03 05 MARTEDI PROG 1 on off 03 03 07 GIOVEDI PROG 1 on off ci 03 03 08 VENERDI PROG 1 03 03 09 SABATO PROG 1 on off DOMENICA PROG 1 on off PROGRAMME 2 Niveau de menu S lection Signification Valeurs possibles 03 03 11 START PROG 2 Heure d activation ora OFF 03 03 12 STOP PROG 2 Heure de d sactivation ora OFF 03 03 13 LUNEDI PROG 2 Jour de r f rence 03 03 18 SABATO PROG 2 3 on off 03 03 19 DOMENICA PROG 2 PROGRAMME 3 iveau de menu S lection Signification Valeurs possibles 03 03 20 START PROG 3 Heure d activation ora OFF 03 03 21 STOP PROG 3 Heure de d sactivation 03 03 22 LUNEDI PROG 3 on off 03 03 23 MARTEDI PROG 3 on off 03 03 24 MERCOLEDI PROG 3 3 on off 03 03 25 GIOVEDI PROG 3 on off 03 03 26 VENERDI PROG 3 on off 03 03 27 SABATO PROG 3 2 on off 03 03 28 DOMENICA PROG 3 PROGRAMME 4 Signification Vale
140. ntenimento del pellet si trova nella parte posteriore della stufa Lo sportello di apertura posizionato nella parte superiore e il caricamento del pellet avviene manualmente solo a stufa spenta ponendo attenzione a non farlo fuoriuscire dal serbatoio L utilizzo di pellet con caratteristiche diverse rispetto a quello testato dal tecnico durante la 1 ac censione implica una nuova taratura dei parametri di carico pellet della stufa tale intervento escluso dalla garanzia Immagazzinare il pellet in luogo asciutto e privo di umidit Ai fini di un funzionamento regolare ed efficiente non possibile il caricamento manuale del pellet o A altri combustibili nel braciere Evitare il caricamento nel serbatoio di combustibili non conformi Evitare il caricamento nel serbatoio di corpi estranei quali contenitori scatole sacchetti metalli etc L utilizzo di pellet scadenti e non conforme danneggia e compromette il funzionamento dell apparecchio facendo decadere la validit della garanzia con esclusione della responsabilit da parte del costruttore 1 6 Accessori in dotazione La dotazione comprensiva di Cavo di alimentazione elettrica Manuale d installazione uso e manutenzione Chiave di apertura chiusura porta fuoco 7 EASY CRONO HR COLA 1 7 Riferimenti normativi Norma UNI 10683 2005 Requisiti di installazione dei generatori di calore alimentati a legna o altri biocombustibili solidi N
141. ntrollo e o manutenzione utili per il corretto utilizzo e funzionamento della stufa pri 1 anno Parti Periodo 1 giorno 2 3 giorni 1 mese 2 3 mesi pulizia straordinaria Tipologia della pulizia pulizia pulizia pulizia pulizia effettuata dal Centro ordinaria ordinaria ordinaria ordinaria Assistenza Tecnico Braciere n Vano cenere cassetto n Vetro n Scambiatore fumi deviatore n Collettore estrattore fumi n Guarnizione porta vetro n Canna raccordo fumario 5 1 Pulizia braciere Togliere il braciere ed asportare i residui di cenere che si sono depositati nella camera di combustione e nel porta braciere A tale scopo pu essere utilizzato un idoneo aspiratore Questa operazione dovr essere eseguita quotidianamente soprattutto in presenza di accumulo di materiale incombusto per assicurare una perfetta condizione di combustione in quanto i fori del braciere permettono il passaggio dell aria di combustione Il braciere deve appoggiare sul porta braciere e precisamente su tutta la fascia anulare senza presentare luci di passaggio aria Braciere pulito i Braciere sporco Porta Braciere pulito 23 EASY CRONO HR COLA 5 2 Pulizia contenitore cenere Direttamente sotto il braciere porta braciere collocato il contenitore cenere Per procedere alla sua pulizia necessario aprire la porta fuoco ed aspirare con un idoneo aspiratore la cenere presente a
142. ore ai 4 5 anni qualora a stufa spenta l orologio non mantiene l orario o alla riaccensione viene visualizzato una serie di zeri necessario procedere alla sostituzione chiamando un centro di assistenza autorizzato 4 6 3 Menu 03 abilita crono Permette di abilitare e disabilitare tutte le funzioni del cronotermostato con la selezione ON si attiva la funzione e viene visualizzata il relativo segmento led D Quando viene inserita la programmazione Giornaliera Settimanale o Week End nella parte superiore del display a destra appare rispettivamente il segmento led appropriato C Entrando nel sottomenu PROGRAM GIORNO possibile abilitare disabilitare e impostare le funzioni del cronotermostato giornaliero AN E possibile settare due fase di funzionamento delimitate dagli gt 11 a g Ue orari impostati secondo la tabella seguente dove l impostazione GE ARE OFF indica all orologio di ignorare il comando 4 r D freni selezione significato valori possibili START 1 ora di attivazione ora OFF Finestra di dialogo START 2 ora di attivazione ora OFF STOP 2 ora di disattivazione ora OFF 19 EASY CRONO HR COLA Entrando nel sottomenu PROGRAM SETTIM possibile abilitare disabilitare e impostare le funzioni del cronotermostato settimanale 4 3 amp Il programmatore settimanale dispone di 4 programmi indipendenti il cui effetto finale composto dalla combinazione M
143. orma UNI EN14785 2006 Requisiti di progettazione fabbricazione costruzione sicurezza e prestazioni istruzioni e marcature unitamente ai relativi metodi di prova per le omologazioni degli apparecchi funzionanti a pellet Norma CEI EN 60335 1 Sicurezza degli apparecchi elettrici d uso domestico e similare parte1 Norma CEI EN 60335 2 102 Sicurezza degli apparecchi elettrici d uso domestico e similare parte 2 Norma CEI EN 55014 1 Resistenza elettromagnetica Requisiti per elettrodomestici attrezzi elettrici e apparecchi elettrici simili Parte 1 Emissione di disturbo Norma CEI EN 55014 2 Resistenza elettromagnetica Requisiti per elettrodomestici attrezzi elettrici e apparecchi elettrici simili Parte 2 Immunit Norma famiglia di prodotti Norma CEI EN 61000 3 2 Limiti per le emissioni di corrente armonica Corrente ingresso lt 16 A per fase Norma CEI EN 61000 3 3 Limitazione delle fluttuazioni di tensione e del flicker in sistemi di alimentazione in bassa tensione per apparecchiature con corrente nominale lt 16 A Norma CEI EN 62233 Metodi di misura per campi elettromagnetici degli apparecchi elettrici di uso domestico e similari con riferimento all esposizione umana Norme DIN plus 51731 UNI EN 14961 2 Norm M 7135 Norme riguardanti le specifiche e la classificazione del pellet 1 8 Targa di identificazione La targa di identificazione visibile sulla superficie interna
144. ot ger les structures autour du po le de la chaleur Une plaque de sol en acier ou en verre tremp doit tre pr vue pour prot ger les parquets ou autres planchers en mati re inflammable moquette linol um etc et doit respecter les distances r glementaires autour du po le Si le conduit de fum e doit traverser des plafonds ou des poutres de bois ou de tout autre mati re combustible celui ci doit amp tre d ment isol selon la r glementation encadrant l installation du po le a granul s La distance minimale de s curit devant le po le pour les objets inflammables est de 1 5 m Les distances minimales de s curit par rapport aux mat riaux combustibles doivent correspondre a l cart au feu indiqu dans le tableau ci apr s Souche de chemin e anti A 300 mm B 200 mm vent C 1500 mm Conduit de Plaque de sol q A y D 200 mm a pe Le Dy 4 7 N I El T Ev Conduit de A B gt raccordement A WAR ile LT PRI Trappe de visite sur Nr le conduit de fum e Prise d air min 100 cm SI Chaque installation doit pr voir un espace technique facilement accessible pour effectuer les op rations d entretien p riodiques Le po le est dot de 4 pieds r glables pour faciliter sa mise en place sur des sols irr guliers Pour r gler la hauteur du pied incliner le po le et tourner le pied jusqu obtenir la juste hauteur 67 EASY CRONO HR COLA
145. our l vacuation des fum es 3 3 S curit en cas de surpression dans la chambre de combustion 3 4 Surchauffe thermostat de s curit temp rature r servoir granul s 3 5 S curit contre le retour de flamme sur le canal d alimentation en granul s 3 6 Dispositif lectrique de protection contre les surtensions 3 7 S curit en cas de coupure de courant 3 8 Dysfonctionnement du ventilateur d extraction des fum es UTILISATION DU POELE 4 1 Introduction 4 2 Description du tableau de commande 4 3 Allumage 4 3 1 Contr le avant l allumage 4 3 2 Mise en marche 4 4 Fonctionnement 4 5 Extinction du po le 4 6 Menu 4 6 1 menu 01 r glage des ventilateurs 4 6 2 menu 02 r glage de l horloge 4 6 3 menu 03 activation du chrono 4 6 4 menu 04 choix de la langue 4 6 5 menu 05 mode veille stand by 4 6 6 menu 06 alarme sonore buzzer 4 6 7 menu 07 chargement initial 4 6 8 menu 08 tat du po le 4 6 9 menu 09 r glages du technicien 5 7 8 61 COLA 4 8 T l commande sur demande 4 7 1 Remplacement de la pile 4 8 Thermostat chronothermostat externe 4 9 P riode d inactivit fin de saison NETTOYAGE DU PO LE 5 1 Nettoyage du brasier 5 1 Nettoyage du cendrier 5 2 Nettoyage de la vitre et des fentes d a ration 5 3 Nettoyage de l extracteur de fum e et de la chambre de combustion 5 4 Nettoyage du d bitm tre 5 5 Nettoyage des carreaux c ramiques
146. pf bei jedem Anz nden bzw Nachf llen von Pellets reinigen Das Rauchrohr und die Zugstabilisatoren in der Brennkammer regelm ig von einem Fachmann reinigen lassen W hrend des Z ndvorgangs und oder beim normalen Betrieb die Bildung von Rauch und unverbrannten Stoffen vermeiden die berm ige Ansammlung von unverbrannten Pellets im Brenntopf muss vor dem erneuten Einschalten von Hand beseitigt werden Weisen Sie Kinder und Besucher auf die oben beschriebenen Gefahren hin Bei Betriebsst rungen darf der Ofen erst nach Behebung der Problemursache wieder angez ndet werden Jegliche nderung und oder jegliches nicht zul ssige Auswechseln mit nicht Original Ersatzteilen des Ofens ist eine Gefahr f r die Benutzer und enthebt den Hersteller von jeder Haftpflicht und strafrechtlichen Verantwortungen Ausschlie lich die vom Hersteller empfohlenen Ersatzteile benutzen Der Hersteller haftet nicht f r St rungen Sch den oder Unf lle die auf die Missachtung bzw Nichteinhaltung der Hinweise in der Betriebsanleitung zur ckzuf hren sind 91 EASY CRONO HR COLA 1 4 Technische Beschreibung Der Pelletofen darf ausschlie lich mit Pellets beschickt werden und verbreitet eine gesunde sichere W rme im Raum Seine automatischen Regelsysteme sorgen f r eine optimale W rmeleistung und eine vollst ndige Verbrennung Die vorhandenen Sicherheitssysteme gew hrleisten einen f r die Ofenkomponenten und den Benutzer sicheren Betr
147. ppareil usag Aux sens de l article 13 du D cret l gislatif n 151 du 25 Juillet 2005 de r alisation de la Directive 2002 96 CE du 23 F vrier 2003 sur les Rebus des Appareillages Electriques et Electroniques relatifs aux mesures et proc dures visant pr venir la production des d chets des appareillages lectriques et lectronique d nomm e RAEE Promouvoir la r utilisation le recyclage et autres formes de r cup ration de fa on r duire la quantit de d chets en am liorant leur coulement par l intervention des diff rentes parties participant au cycle de vie de tels produits Le symbole barr de la boite de tri indiqu sur l tiquette du produit indique que le produit la fin de sa vie doit tre vacu s par ment des autres d chets 1 10 Demande d intervention et de pi ces d tach es Pour toute demande d intervention et ou de pi ces d tach es contacter son revendeur le revendeur de zone ou le centre d assistance agr le plus proche en pr cisant toujours mod le du po le num ro de s rie date d achat liste des pi ces de rechange les anomalies de fonctionnement constat es Avant de proc der aux op rations s assurer que toutes les connexions lectriques sont d branch es et que le po le est froid N utiliser que des pi ces de rechange d origine N Les interventions sur les composants doivent tre effectu es par un personnel agr et ou qualifi 66 EASY CRONO HR COL
148. pui voir chapitre 2 Transport et Installation En pr sence d objets consid r s comme particuli rement d licats tels que meubles rideaux divans installer le po le une distance plus loign e de ceux ci 3 2 S curit pour l vacuation des fum es Normalement la chambre de combustion fonctionne en d pression et garantit l tanch it contre toute fuite de gaz dans l environnement En cas de valeur de d pression insuffisante ou de conduit de fum e obstru le vacuostat de s curit d tecte le manque de d pression l int rieur de la chambre de combustion ou le d bitm tre d c le l absence de flux d air comburant et arr te le fonctionnement du moteur de rotation de la vis sans fin par l interm diaire de l unit Le message AL8 MANQUE DEPRESS ou AL9 TIRAGE INSUFF s affichera alors sur le tableau de commande 3 3 S curit en cas de surpression dans la chambre de combustion En cas de surpression inattendue des fum es de combustion l int rieur de la chambre et des conduits d vacuation les fum es seront vacu es travers des soupapes de s ret install es au dessus de l changeur de chaleur Durant le fonctionnement normal ces soupapes restent ferm es sous leur propre poids et sous l effet de la d pression de la chambre de combustion de sorte garantir l tanch it contre l vacuation ventuelle des fum es A Contr ler r guli rement que le dispositif est ferm qu il est e
149. ra di combustione 2 Supporti dx sx EASY CRONO HR 3 Scambiatore in ghisa 4 Pareti laterali vermiculite 5 Deviatore superiore vermiculite 6 Parete posteriore vermiculite Legenda Vista esplosa della camera di combustione e delle parti collegate rif stufa EASY CRONO HR EASY CRONO HR 26 COLA Rappresentazioni esplose di 1 Gruppo braciere 2 Gruppo estrattore fumi 3 Gruppo coclea Legenda 1 Braciere 2 Porta braciere 3 Guppo tubo aspirazione aria comburente 4 Resistenza elettrica 5 Guarnizione posteriore portabraciere 6 Guarnizione anteriore gruppo aspirazione Legenda 1 Voluta estrattore fumi 2 Guarnizione termica 3 Motore estrattore fumi 4 Tubo espulsione fumi Legenda 1 Guarnizione serbatoio convogliatore 2 Flangia ferma motoriduttore 3 Motoriduttore 4 Coclea 5 Guarnizione per scivolo 6 Scivolo caduta pellet 7 Guarnizione camera convogliatore 8 Convogliatore pellet 27 EASY CRONO HR COLA 6 4 Componenti elettrici 902 2990 os 0950 9 d 0 900352 99 300050 0995 0250 9 0250 n 0096 00 2900 n 2 n 900999 03 d 200059 002509509500 095005 003509509350 005005 9003502502 0 92000 0092 o 022 250990 09502 o 9 9 9 30 2 9 o 229 o 2 200050090009 090 099999509502 230 o 229223209023 928 99 930 099 250 o o 90950 92250250230 290000 9790970992 0959 00 09509 o 2 09990 0950 o 92990 099299 000 20 o 09 o n
150. ra di disattivazione ora OFF 03 03 31 LUNEDI PROG 4 on off MERCOLEDI PROG 4 on off VENERDI PROG 4 2 on off SABATO PROG 4 S onoff 03 03 37 DOMENICA PROG 4 on off 20 EASY CRONO HR COLA Entrando nel sottomenu PROGRAM WEEK END possibile Livello di menu abilitare disabilitare e impostare le funzioni del cronotermostato nel week end fine settimana sabato domenica HJE Attivare la programmazione WEEK END solamente i ut 3 U 0 3 dopo aver disattivato la programmazione settimanale Br AL AI fine di evitare operazioni di avvio e spegnimento non G E n m AN voluti attivare un solo programma per volta Disattivare il programma giornaliero se si desidera A NEEH End impiegare quello settimanale con questa impostazione opportuno disattivare il programma week end Livello di menu 4 6 4 Menu 04 scegli lingua E Con questa selezione possibile selezionare la lingua di dialogo tra quelle precisamente w ITALIANO 7 FRANCESE pi Auen DH INGLESE PEALIAMG TEDESCO 4 6 5 Menu 05 modo stand by Finestra di dialogo Con la selezione ON nella modalit STAND BY la stufa si spegne automaticamente dopo che la temperatura ambiente o la temperatura dell acqua rimasta superiore al valore di SET per un tempo prefissato La successiva riaccensione in automatico sar possibile solamente quando la temperatura ambiente o dell acqua scende al di sotto
151. ramite un proprio termostato digitale che ha la funzione di rilevare la temperatura attraverso una sonda e di abbassare la potenza quando viene raggiunta la temperatura impostata Se si desidera utilizzare un termostato esterno rivolgersi ad un tecnico autorizzato e seguire le seguenti indicazioni spegnere l apparecchio agendo sull interruttore generale posto sul lato posteriore e staccare il cavo dall alimentazione smontare la pannellatura laterale per accedere al controllo elettronico con riferimento allo schema elettrico collegare i due cavi del termostato sui relativi morsetti TERM della scheda rimontare il tutto e verificare il corretto funzionamento Di seguito viene riportata la procedura di impostazione termostato esterno impostare un SET temperatura pari a 70 cronotermostato esterno impostare un SET temperatura pari a 7 e disabi litare dal menu 03 01 le funzionalit crono Per ognuna delle impostazioni tutte le funzioni del menu non cambiano e la segnalazione del collegamento avviene con l accensione del led a segmento sullo barra degli stati nel display 22 EASY CRONO HR COLA 4 9 Periodo di inattivit fine stagione Se la stufa non viene utilizzata per lunghi periodi e o a fine di ogni stagione consigliato operare come segue togliere completamente il pellet dal serbatoio scollegare l alimentazione elettrica e togliere il cavo dall interruttore pulire ac
152. re d assistance agr La soci t COLA s r l se r serve d apporter des modifications techniques ou esth tiques ses produits n importe quel moment et sans pr avis Toutes les configurations les dessins les mesures et les sch mas sont fournis titre d exemple 88 EASY CRONO HR COLA 8 ANNEXES INFORMATIONS RELATIVES AU MARQUAGE CE CE COLA 2012 EN 14785 2006 Appareils de chauffage domestique granul s de bois R f EASY CRONO HR Distance minimale de s curit par rapport aux mat riaux inflammables 200 300 0 mm A l arri re sur les c t s droit et gauche au sol Emissions de CO 13 O2 dans les produits de P nom 0 01 combustion P red 0 02 Emissions de poussi res 13 O2 dans les produits de 3 combustion P nom 6 1 mg m Pression max d eau de service admissible bar P nom 182 2 C Temp rature des fum es P r d 80 2 P nom 9 29 kW Puissance thermique nominale r duite P red 2 58 kW P nom 89 26 Hengemen P red 95 66 Types de combustible Granul s de bois Puissance lectrique 420 W 120 W Tension nominale 230 V Fr quence nominale 50Hz 89 EASY CRONO HR 1 ALLGEMEINE HINWEISE 1 1 Vorwort 1 2 Nachschlagen im Handbuch 1 3 Sicherheitsvorschriften 1 4 Technische Beschreibung 1 5 Brennstoff und zul ssiger Gebrauch 1 6 Zubeh r 1 7 Bezugsnor
153. reich des Ofens Die T r befindet sich im oberen Teil und die Pelletbeschickung erfolgt von Hand nur bei ausgeschaltetem Ofen dabei darauf achten dass der Beh lter nicht berl uft Bei Verwendung von Pellets mit anderen Eigenschaften als vom Techniker bei der ersten Inbetriebnahme getestet m ssen die Parameter der Pelletbeschickung des Ofens neu eingestellt werden Dieser Eingriff ist von der Garantie ausgeschlossen Die Pellets m ssen an einem trockenen vor Feuchtigkeit gesch tzten Ort gelagert werden Um einen regul ren und effektiven Betrieb sicherzustellen k nnen die Pellets oder andere Brennstoffe A nicht von Hand in den Brenntopf gef llt werden Den Tank nicht mit ungeeigneten Brennstoffen f llen Keine Fremdk rper in den Pelletbeh lter einf hren z B Verpackungen Schachteln Beutel Metall USW Durch die Verwendung minderwertiger und ungeeigneter Pellets wird das Ger t besch digt und der Betrieb beeintr chtigt In diesem Fall verf llt jeder Garantieanspruch und die Haftung des Herstellers wird ausgeschlossen 1 6 Zubeh r Der Lieferumfang umfasst Netzkabel Installations Gebrauchs und Wartungsanleitung Schl ssel zum ffnen Schlie en der Feuerraumt r 94 EASY CRONO HR COLA 1 7 Bezugsnormen Norm UNI 10683 2005 Installationsanforderungen der mit Holz oder anderen biologischen Festbrennstoffen betriebenen W rmeerzeuger Norm EN14785 2006 Anforderungen an Auslegung Herstellung Au
154. reichem Abschluss des Z NDVORGANGS wechselt der Ofen auf den normalen Betriebszustand BETRIEB Der Benutzer kann die Heizleistung mit den Tasten P5 und P6 von der h chsten Heizstufe 5 bis zur kleinsten Heizstufe 1 regeln 103 EASY CRONO HR COLA Raumtemperatur 1436 ere ORK Dialogfenste Sollleistung 4 Neben der Leistungsstufe kann mit den Tasten P1 und P2 auch die Raumtemperatur direkt am Bedienpanel eingestellt werden Auf dem Display wird der aktuelle Status des Temperatur Sollwerts angezeigt F r das Hei luftgebl se regelt der Ofen die Drehzahl automatisch entsprechend der eingestellten Leistungsstufe Eingestellter Raumtemperaturwert Taste P1 H 2 g C ser SEL rRiiubtEnP Unbedingt den F llstand der Pellets im Beh lter kontrollieren um zu vermeiden dass die Flamme A aufgrund von Brennstoffmangel erlischt Zum Einf llen der Pellets muss der Ofen ausgeschaltet sein Il coperchio del serbatoio pellet deve rimanere sempre chiuso va aperto durante solamente durante il caricamento del combustibile Die Pellets cke m ssen in mindestens 1 5 m Entfernung vom Ofen aufbewahrt werden Sobald die Raumtemperatur den vorgegebenen Wert erreicht hat oder die Abgastemperatur den vorgegebenen H chstwert erreicht hat erscheint auf dem Bedienpanel die Meldung MODULIEREN x F e und der Ofen aktiviert den Vorgang zur Flammenmodulation 36 ohne dass der Bediener eingreifen
155. remdk rpern verhindern und in jeder Witterung die Abf hrung der Verbrennungsprodukte sicherstellen er muss eine angemessene Verd nnung der Produkte garantieren und au erhalb des R ckflussbereichs positioniert sein er muss frei von mechanischen Saugvorrichtungen sein Die direkte Abf hrung der Verbrennungsprodukte muss vom Dach erfolgen Die Abf hrung in geschlossene Bereiche auch unter freiem Himmel ist verboten 2 5 Positionskontrolle von Brenntopf und Abweiser Vor dem Einschalten des Ofens unbedingt kontrollieren ob sich der Brenntopf in korrekter Position befindet d h in den hierf r vorgesehenen Aufnahmen eingerastet ist Inoltre controllare che il deviatore fumi superiore sia incastrato nella propria sede Una posizione errata del deviatore comporta malfunzionamenti ed un eccessivo annerimento del vetro A Jedes Mal wenn das Ger t eingeschaltet werden muss die korrekte Position des Brenntopfes im Brenntopfhalter kontrolliert werden 2 6 Elektrischer Anschluss Das eine Ende des Netzkabels an den Stecker an der Ofenr ckseite das andere Ende an eine Wandsteckdose anschlieBen Die vom Stromnetz gelieferte Spannung muss den Angaben auf dem Typenschild des Ofens und den im vorliegenden Handbuch enthaltenen technischen Daten entsprechen Wenn der Ofen nicht benutzt wird den Stromanschluss trennen einer Erdung und einem Fehlerstromschutzschalter ausgestattet sein Die elektrische Anlage muss vorschriftsm i
156. rer d avoir d branch le cordon d alimentation lectrique et que le po le est froid 6 2 D pose de l habillage L gende 1 Couvercle en c ramique 2 Fa ade inf rieure 3 Panneau arri re 4 Protection motor ducteur 5 Flanc droit 6 Flanc gauche 7 Couvercle de r servoir granul s 83 EASY CRONO HR COLA 6 3 Composants internes du po le N VIS N Lp NAS SS pp VG ME OR E 1G ES ey Eclat de la chambre de combustion et des parties reli es r f po amp le EASY CRONO HR 2 Supports droit et gauche EASY CRONO 3 Echangeur en fonte 5 D flecteur sup rieur vermiculite 1 Chambre de combustion 4 Parois lat rales vermiculite 6 Paroi post rieure vermiculite L gende EASY CRONO HR 84 COLA clat s de 1 Groupe brasier 2 Groupe extracteur des fum es 3 Groupe vis sans fin L gende 1 Brasier 2 Support de brasier 3 Tuyau d aspiration d air comburant 4 R sistance lectrique 5 Joint arri re de support de brasier 6 Joint avant du groupe aspiration L gende 1 Volute extracteur de fum es 2 Joint thermique 3 Moteur d extracteur de fum es 4 Tuyau d vacuation des fum es L gende 1 Joint de r servoir convoyeur 2 Flasque d arr t motor ducteur
157. rise d air ayant une surface minimum de 100 cm proximit du po le et communiquant avec l ext rieur prot g e par une grille ext rieure gt directement l ext rieur par tuyau d un diam tre int rieur minimum de 50 mm et d une longueur maximale de 1 5 m muni d un terminal de protection anti vent coude orient vers le bas Le flux d air peut provenir aussi d un local adjacent celui d installation pour autant que cette amen e puisse se faire librement travers des ouvertures permanentes communiquant avec l ext rieur ce local ne peut pas tre destin tre utilis comme garage ni comme magasin de mat riaux combustibles ou pour des activit s comportant des risques d incendie 2 4 Evacuation des fum es de combustion Les fum es peuvent tre vacu es par un conduit de fum e traditionnel ou par un conduit ext rieur isol ou double paroi Les conduits de raccordement doivent garantir un tirage minimum de 10 Pa de mani re pouvoir assurer l vacuation des fum es en cas de coupure de courant momentan e Il estrecommand l installateur de v rifier l efficacit et l tat de la chemin e ainsi que la conformit la r glementation locale nationale et europ enne en vigueur Utiliser imp rativement des tuyaux ou conduits et raccords certifi s avec des joints ad quats qui garantissent l tanch it En cas d incendie teindre le po le appeler imm diatement les pompiers et viter to
158. rmance of all operators involved in the life cycle of electrical and electronic equipment The picture of the bin crossed is labelled on the equipment and it means that when the device is out of use it has to be kept separated by other wastes 1 10 Instructions for requesting assistance and replacement parts To request any assistance and or replacement parts contact your dealer area importer or the nearest authorised service centre clearly specifying the following stove model serial number date of purchase list of replacement parts details of faults or malfunctioning Make sure all electrical connections are disconnected and that the stove is cold before any work on it N All operations on components must be carried out by authorised and or qualified personnel Only use original replacement parts 37 EASY CRONO HR COLA 2 TRANSPORT AND INSTALLATION 2 1 Packing handling shipment and transport The stove complete with packing can be lifted using a lift truck inserting the forks of suitable length in the special spaces in the wooden pallet Make sure the equipment used for lifting and transport can take the weight of the stove specified on the dataplate and in this manual Avoid taking the load in areas where it could be a danger if dropped Open the packing remove the stove from the pallet and position it in the required place making sure it complies with that provided for Set the stove down on the floor carefully w
159. s Men dieses ist in verschiedene Optionen und Ebenen unterteilt ber die die Einstellungen der elektronischen Regelung aufgerufen werden k nnen In der nachstehenden bersicht ist die Men struktur und nur die f r den Benutzer verf gbaren Optionen dargestellt Ebene 1 Ebene 2 Ebene 3 Ebene 4 Wert 01 L fter regeln Wert w hlen 02 Uhr einstellen 01 Tag Tag 02 Stunden Stunden 03 Minuten Minuten 04 Tag Tag 05 Monat Monat 06 Jahr Jahr Ebene 1 Ebene 2 Ebene 3 Ebene 4 Wert 03 Uhrenthermostat einstellen 01 Uhrenthermostat aktivieren 01 Uhrenthermostat aktivieren on off 02 Program Tag 01 Uhrenthermostat Tag on off 02 Start 1 Tag Uhrzeit 03 Stop 1 Tag Uhrzeit 04 Start 2 Tag Uhrzeit 05 Stop 2 Tag Uhrzeit 03 Program Woche 01 Uhrenthermostat Woche on off 105 EASY CRONO HR COLA 02 Start 1 Tag Uhrzeit 03 Stop 1 Tag Uhrzeit 04 Montag Prog 1 on off 05 Dienstag Prog 1 on off 06 Mittwoch Prog 1 on off 07 Donnerstag Prog 1 on off 08 Freitag Prog 1 on off 09 Samstag Prog 1 on off 10 Sonntag Prog 1 on off 11 Start Prog 2 Uhrzeit 12 Stop Prog 2 Uhrzeit 13
160. s conditions climatiques ext rieures m mes critiques vent fort gel etc car les systemes de s curit dont il est quip arr teront son fonctionnement extinction Structure Acier fonte et faience majolique Chambre de combustion acier et fonte Puissance thermique nominale r duite P nom 9 29 kW P red 2 58 kW Consommation horaire P nom P red P nom 2 2 kg h P red 0 57 kg h Rendement P nom P red P nom 89 26 P red 95 66 Temperature de sortie des fumees P nom P red P nom 182 25 P red 80 2 Emissions CO 13 02 P nom 0 01 P r d 0 02 D bit gaz de combustion P nom 6 5 g s P r d 2 2 g s Emissions de poussi res P nom 6 1 mg m Tirage du conduit de fum e 10 14 Pa Tuyau d vacuation des fum es 80 mm Tuyau de prise d air 50 mm Alimentation lectrique 230V 50 Hz Consommation lectrique op mere an piese dall uage pendant le fonctionnement normal E s curit l arri re sur le c t droit sur 200 300 0 mm Dimensions mm HxLxP 990 x 582 x 499 mm Poids du po le 98 kg Capacit du r servoir a granul s 31 litres 22 kg Volume max de chauffe 212 m La consommation de granul s varie en fonction du type de granul s utilis s et du stockage En consid rant 35 W h par m Le besoin nerg tique de l difice peut varier en fonction de l isolation du type de construction et de la zone climat
161. seite des Ger ts eingesetzt wird Zum Einsetzen und eventuellen Wechseln der Batterie folgenderma en vorgehen Abdeckung an der R ckseite der Fernbedienung ffnen Batterie Modell p23ga 12V einlegen dabei auf die korrekte Polung achten Fernbedienung schlie en Kontrollieren ob die Fernbedienung korrekt funktioniert Die Fernbedienung fern von direkten W rmequellen und Wasser halten Die Batterie der Fernbedienung muss sicher und unter Befolgung der rtlichen Vorschriften ausgewechselt und entsorgt werden 4 8 Thermostat externer Uhrenthermostat Serienm ig regelt das Ger t die Raumtemperatur mit einem Digitalthermometer der die Temperatur ber einen Temperaturf hler misst und bei Erreichen der eingestellten Temperatur die Leistung verringert Wenn ein externer Thermostat verwendet werden soll wenden Sie sich bitte an einen befugten Techniker der die folgenden Anleitungen befolgen muss Ger t mit dem Hauptschalter an der R ckseite ausschalten und Netzkabel trennen Die seitliche Verkleidung abnehmen um die elektronische Regelung freizulegen Unter Bezugnahme auf den elektrischen Schaltplan die zwei Kabel des Thermostats an die Klemmen TERM der Platine anschlie en Alles wieder einbauen und den korrekten Betrieb kontrollieren Wie folgt konfigurieren Externer Thermostat Einen Temperatur Sollwert von 7 einstellen Externer Uhrenthermostat Einen Temperatur Sollwert von 7 einste
162. sentielles concernant l installation des g n rateurs de chaleur bois ou d autres biocombustibles solides Norme UNI EN14785 2006 elle fixe les exigences essentielles relatives la conception la fabrication la s curit aux performances rendement et missions aux instructions et aux marquages ainsi qu aux m thodes d essai correspondantes pour les essais de type d appareils fonctionnant aux granul s de bois Norme CEI EN 60335 1 Appareils lectrodomestiques et analogues S curit Partie 1 Norme CEI EN 60335 2 102 Appareils lectrodomestiques et analogues S curit Partie 2 Norme CEI EN 55014 1 Compatibilit lectromagn tique Exigences pour les appareils lectrodomestiques outillages lectriques et appareils analogues Partie 1 mission Norme CEI EN 55014 2 Compatibilit lectromagn tique Exigences pour les appareils lectrodomestiques outillages lectriques et appareils analogues Partie 2 Immunit Norme famille de produits Norme CEI EN 61000 3 2 Limites pour les missions de courant harmonique courant appel par les appareils inf rieur ou gal 16 A par phase Norme CEI EN 61000 3 3 Limitation des variations de tension des fluctuations de tension et du papillotement dans les r seaux publics d alimentation basse tension pour les mat riels ayant un courant assign inf rieur ou gal 16 A par phase et non soumis un raccordement conditionne
163. sf hrung Sicherheit und Leistungsverm gen Anleitung und Kennzeichnung zusammen mit zugeh rigen Pr fverfahren f r die Typpr fung von Raumheizern f r Holzpellets Norm EN 60335 1 Sicherheit elektrischer Ger te f r den Hausgebrauch und hnliche Zwecke Teil 1 Norm EN 60335 2 102 Sicherheit elektrischer Ger te f r den Hausgebrauch und hnliche Zwecke Teil 2 Norm EN 55014 1 Elektromagnetische Vertr glichkeit Anforderungen an Haushaltsger te Elektrowerkzeuge und hnliche Elektroger te Teil 1 St raussendung Norm EN 55014 2 Elektromagnetische Vertr glichkeit Anforderungen an Haushaltsger te Elektrowerkzeuge und hnliche Elektroger te Teil 2 St rfestigkeit Produktfamiliennorm Norm EN 61000 3 2 Grenzwerte f r Oberschwingungsstr me Ger te Eingangsstrom lt 16 A je Leiter Norma CEI EN 61000 3 3 Begrenzung von Spannungsschwankungen und Flicker in Niederspannungs Versorgungsnetzen f r Ger te mit einem Bemessungsstrom lt 16 A je Leiter Norm EN 62233 Verfahren zur Messung der elektromagnetischen Felder von Haushaltsger ten und hnlichen Elektroger ten in Bezug auf die menschliche Exposition Normen DIN plus 51731 UNI CEN TS 14961 Norm M 7135 Normen ber die Spezifikation und Klassifizierung von Pellets 1 8 Typenschild Das Typenschild befindet sich innen an der T r des Pelletbeh lters oder an der Ofenr ckwand Folgende Daten sind darauf angegeben Modell gt Strom
164. so un allacciamento ad una canna fumaria tradizionale oppure ad un condotto esterno con tubo isolato o a doppia parete collegamenti di scarico fumi devono garantire un tiraggio minimo di 10 Pa in modo tale che in caso di mancanza temporanea di alimentazione elettrica l evacuazione fumi venga assicurata Si raccomanda all installatore di verificare l efficienza e lo stato della canna fumaria la rispondenza alle disposizioni regole locali norme nazionali ed europee A E necessario utilizzare tubi e raccordi certificati con adeguate guarnizioni che garantiscono la tenuta In caso di incendio spegnere la stufa chiamare tempestivamente i pompieri ed evitare continui tentativi di spegnimento Pulire almeno una volta all anno il condotto fumario e il relativo raccordo fumi 2 4 1Tipologie delle installazioni Di seguito vengono elencate definizioni e requisiti per realizzare secondo Norma italiana UNI10683 per la corretta installazione di uno scarico fumario CAMINO condotto verticale avente lo scopo di raccogliere ed espellere ad un opportuna altezza dal suolo i prodotti di combustione provenienti da un solo apparecchio e nei casi consentiti pi di uno Requisiti tecnici CAMINO essere a tenuta dei prodotti di combustione Comigndlo isolato e coibentato in funzione dell impiego antivento SISS avere un andamento prevalentemente verticale con deviazioni di y dall asse lt 45 fumaria essere adeguatamente dis
165. stato della Temperatura ambiente 6 Ss Putsanto 2 pi SEE EP A ibi EntE N Si raccomanda di controllare il livello del pellet nel serbatoio per evitare che la fiamma si spenga per mancanza di pellet Durante il caricamento del pellet assicurarsi che l apparecchio sia spento Il coperchio del serbatoio pellet deve rimanere sempre chiuso va aperto durante solamente durante il caricamento del combustibile sacchi di pellet devono essere riposti lontano dalla stufa almeno 1 5 m Quando la temperatura ambiente ha raggiunto il valore impostato Temperatura ambiente oppure la temperatura fumi ha raggiunto il valore massimo settato compare sul pannello di controllo il messaggio MODULA F e la stufa attiva la procedura di modulazione della fiamma senza alcun 14 96 intervento dell utente mentre se la temperatura supera i 280 g rc P U appare l allarme ALLARM HOT FUMI e la stufa attiva la i procedura di spegnimento L ALORG Se viene attivata la modalita STAND BY la stufa si spegne con es 9A un tempo di ritardo dopo aver raggiunto il SET di temperatura Il Finestra di dialogo riavvio avviene dopo che la temperatura ambiente inferiore ad 16 EASY CRONO HR un certo valore prefissato rispetto alla temperatura ambiente COLA Temperatura ambiente ma 136 Durante la normale operativit nella modalit lavoro a intervalli a e rc P y prestabiliti viene attivata la modalit PULIZIA
166. t 1 LAHUN6 Int EL AL 4 6 8 Men 08 Betriebszustand des Ofens Mit dieser Option kann der aktuelle Betriebszustand des Ofens aufgerufen und der Status der verschiedenen daran angeschlossenen Vorrichtungen angezeigt werden f r die Uberwachung stehen mehrere aufeinander folgende Seiten zur Verf gung 4 6 9 Men 09 Vom Techniker vorgenommene Einstellungen Diese Option ist ausschlie lich dem vom Kundendienst COLA befugten Techniker vorbehalten etwaige willk rliche nderungen k nnen ernste Sch den verursachen und entbinden die Firma COLA i Die technischen Parameter im Men 09 d rfen nur von hierzu befugtem Fachpersonal ge ndert werden von jeder Haftung 109 EASY CRONO HR COLA 4 7 Fernbedienung Die Fernbedienung funktioniert mit den am Bedienpanel vorgenommenen Einstellungen und dient zum Ein Ausschalten des Ofens sowie zur Regelung der Leistung und der gew nschten Temperatur Da sie an eine Infrarotdiode sendet muss sie zum Empf nger im Bedienpanel gerichtet werden Die Fernbedienung gestattet folgende Vorg nge A a L I gt L Die LED leuchtet bei jedem Tastendruck auf a RIT Taste P1 P6 Ofen ein ausschalten Taste P1 Raumtemperatur erh hen Taste P6 Leistungsstufe erh hen Taste P5 Leistungsstufe verringern Taste P2 Raumtemperatur verringern 4 7 1 Batterie wechseln Die Fernbedienung wird ohne Batterie geliefert sie funktioniert mit einer Batterie die an der Unter
167. t die Anzeige EINSCHAL Diese Phase ist automatisch und wird von der Regelung gesteuert ohne die Parameter ndern zu k nnen Raumtemperatur Taste P4 Dialogfenster Der Ofen f hrt nacheinander die von den Parametern f r Ebenen und Zeit vorgegeben Einschaltphasen durch und ist danach betriebsbereit sofern keine der in der nachstehenden bersicht aufgef hrten St rungen oder Alarme auftreten Status Dauer Vorrichtungen Bedingungen f r den Wechsel auf n chsten Status ante act tr me AUS OFF OFF OFF OFF ON OFF START VORERW Pr33 OFF ON OFF OFF Ablauf Zeit Pr33 Sek PELLETS NACHF LLEN p40 ON I N Ablauf Zeit Pr40 Sek WARTEN AUF FLAMME py 41 ON Ablauf Zeit Pr41 Sek PELLETS EINF LLEN ON N Abgastemperatur Pr13 FEUER VORHANDEN Ablauf Zeit Pr02 Sek ARBEIT om ov on a CE er Mon o ox o o een BET Temperate BRENNTOPFREINIGUNG Pri OFF ON ON ON Mit Invervall Pr03 ARBEIT gt OFF ON ON ON ON OFF zum Ausschalten ENDREINIGUNG Pr39 OFF ON OFF Pr39 Ab dem Moment in dem Abgastemp lt Pr13 Wenn die Abgastemperatur nach Ablauf einer bestimmten Zeit nicht den zul ssigen Mindestwert erreicht hat schaltet der Ofen auf Alarmzustand 4 4 Betriebsphase Der Ofen darf nicht mit entz ndlichen Fl ssigkeiten angez ndet werden Sollten wiederholt Probleme beim Anz nden auftreten kontaktieren Sie bitte den Kundendienst Nach erfolg
168. tanziato da materiali infiammabili con intercapedine d aria o isolante avere sezione interna preferibilmente circolare costante libera ed indipendente Camera consigliato che il camino sia dotato di camera ispezionabile per la ispezionabile raccolta di materiali solidi Le ed eventuali condense collocato sotto l imbocco del canale da fumo sem min cm Distanza min 0 2m CANALE o RACCORDO da FUMO condotto o elemento di collegamento tra apparecchio e camino per l evacuazione dei prodotti della combustione Requisiti tecnici CANALE non deve attraversare locali nel quali vietata l installazione di apparecchi da combustione vietato l uso di tubi metallici flessibili o in fibro cemento vietato l impiego di elementi in contro pendenza nei tratti orizzontali devono avere andamento con pendenza minima del 3 verso l alto la lunghezza del tratto orizzontale deve essere minima e non maggiore di 3 m il numero di cambi direzione senza il raccordo a T non deve essere maggiore di 3 10 EASY CRONO HR COLA con cambio di direzione gt 90 usare al max 2 curv e con lunghezza in proiezione orizzontale non maggiore di 2 m il canale da fumo deve essere a sezione costante e permettere il recupero della fuliggine COMIGNOLO dispositivo posto alla sommit del camino atto a facilitare la dispersione in atmosfera dei prodotti della combustione Requ
169. tfernen Den W rmetauscher aus Gusseisen durch L sen der Befestigungsschraube ausbauen Die Abweiser und die Kammer reinigen Au erdem muss unbedingt das unter der Kammer befindliche Saugzuggebl se gereinigt werden zu dem man nach Entfernen des Aschekastens Zugang hat Alle 3 4 Monate die isolierenden feuerfesten Innenw nde der Brennkammer mit geeigneten Utensilien Pinseln reinigen und gegebenenfalls ersetzen da sie als Verschlei material gelten Alle 1800 Betriebsstunden fordert der Ofen mit der Meldung SERVICE F LLIG eine nicht von Garantie gedeckte au erordentliche Wartung durch Fachpersonal an das eine vollst ndige Reinigung und die R cksetzung der Meldung vornimmt A Durch St e oder gewaltsames Vorgehen kann das Saugzuggebl se besch digt und dessen lauter Betrieb verursacht werden deshalb sollte mit diesem Vorgang unbedingt qualifiziertes Fachpersonal betraut werden 5 5 Reinigung des Luftmassenmessers In das Rohr ist ein Luftmassenmesser eingebaut Messger t der Verbrennungsluftzufuhr der regelm ig d h alle 3 4 Monate mit geeigneten Mitteln Druckluftstrahl oder geeignete Pinsel innen gereinigt werden muss 5 6 Reinigung der Keramikteile Keramikofenmodelle Die Kacheln sind in Handwerksarbeit hergestellt und k nnen daher geringf gige Oberfl chen Unregelm igkeiten wie Mikroporen oder Farbabweichungen aufweisen F r ihre Reinigung ein weiches trockenes Tuch verwenden durch die Verwendung vo
170. tipo di installazione L operazione di pulizia prevede l aspirazione e la rimozione dei residui su tutti i tratti verticali e orizzontali nonch le curve dall apparecchio alla canna fumaria E consigliato pulire annualmente anche la canna fumaria per avere la garanzia di una corretta e sicura evacuazione dei fumi assistenza autorizzato che oltre ad eseguire le operazioni di pulizia verificher anche lo stato di usura Per qualsiasi manutenzione e pulizia di fine stagione la ditta COLA consiglia di affidarsi ad un centro di IN dei componenti interni alla stufa 24 EASY CRONO HR COLA 6 MANUTENZIONE 6 1 Premessa Gli interventi sui componenti interni della stufa devono essere effettuati da personale qualificato rivolgendosi al centro assistenza autorizzato pi vicino Prima di ogni intervento accertarsi che sia disinserita la spina dell alimentazione elettrica e la stufa sia completamente fredda 6 2 Smontaggio rivestimento Legenda 1 Coperchio in ceramica superiore 2 Frontalino inferiore 3 Pannello posteriore 4 Protezione motoriduttore 5 Pannello laterale dx 6 Pannello laterale sx 7 Sportello serbatoio pellet 25 EASY CRONO HR COLA 6 3 Componenti interni della stufa N VIS N Lp NAS CS Do VG ME OR E 1G ES ey 1 Came
171. to sicurezza temperatura serbatoio pellet 3 5 Sicurezza contro il ritorno di fiamma sul canale alimentazione pellet 3 6 Dispositivo elettrico di protezione della sovracorrente 3 7 Sicurezza da interruzione di alim elettrica 3 8 Guasto ventilatore fumi 8 ALLEGATI 8 1 Informazioni marcatura CE 4 USO DELLA STUFA 4 1 Premessa 4 2 Descrizione del pannello comandi 4 3 Accensione 4 3 1 Controllo prima dell accensione 4 3 2 Fasedi avvio 4 4 Fase di lavoro 4 5 Spegnimento stufa 4 6 Men 4 6 1 men 01 regola ventole 4 6 2 men 02 set orologio 4 6 3 men 03 abilita crono 4 6 4 men 04 scegli lingua 4 6 5 men 05 modo stand by 4 6 6 men 06 cicalino 4 6 7 men 07 carico iniziale 4 6 8 men 08 stato stufa 4 6 9 men 09 tarature tecnico 3 EASY CRONO HR COLA 1 AVVERTENZE GENERALI 1 1 Introduzione Gentile Cliente Desideriamo innanzi tutto ringraziarLa per la fiducia accordataci acquistando un nostro prodotto La invitiamo a leggere e seguire attentamente i consigli contenuti in questo manuale d installazione uso e manutenzione al fine di poter sfruttare al meglio le qualit del prodotto 1 2 Come utilizzare il manuale La ditta produttrice si riserva di apportare in qualsiasi momento senza preavviso alcuno eventuali modifiche tecniche od estetiche ai prodotti Le operazioni d installazione uso e manutenzione della stufa devono soddisfare i requisiti descritti in questo man
172. tung der Statusanzeigen VV en links am Display aufgef hrt DA F rderschnecke Wenn im Display eines der Segmente aufleuchtet wurde die jeweilige in der nebenstehenden Liste aufgef hrte Vorrichtung aktiviert 4 3 Einschalten Saugzuggebl se W rmetauscher 2 Unbenutzt AN Alarm 4 3 1 Kontrolle vor Inbetriebnahme Vor dem Einschalten des Ofens m ssen folgende Kontrollen durchgef hrt werden Die Betriebsanleitung muss gelesen und verstanden worden sein Der Beh lter muss mit Pellets gef llt sein Die Brennkammer muss sauber sein Der Brenntopf muss sauber vollst ndig frei von eventuellen Verbrennungsr ckst nden und korrekt im Brenntopfhalter positioniert sein Feuerraumt r und Aschekasten m ssen dicht verschlossen sein Das elektrische Kabel muss korrekt angeschlossen sein und der Schalter an der Ofenr ckseite muss auf ON 1 stehen 102 EASY CRONO HR COLA Wenn der Ofen zum ersten Mal in Betrieb genommen wird alle brennbaren Teile Betriebsanleitung Etikett aus dem Feuerraum nehmen und von der Glasscheibe entfernen Wird der Ofen nach l ngerem Stillstand eingeschaltet m ssen die eventuell schon lange im Beh lter liegenden Pelletreste durch neue Pellets ersetzt und die Brennkammer vollst ndig gereinigt werden da dieser Brennstoff feucht und nicht mehr zur Verfeuerung geeignet ist 4 3 2 Z ndvorgang Zum Einschalten des Ofens die Taste P4 3 Sekunden lang dr cken Auf dem Display erschein
173. u erordentliche Wartung mindestens 1 Mal pro Jahr vom Vertragskundendienst durchgef hrt werden muss Zur Reinigung aller Teile muss der Ofen kalt und vom Stromnetz getrennt sein A Die Reinigungsr ckst nde gem den geltenden rtlichen Vorschriften entsorgen Der Ofen darf auf keinen Fall ohne Au enverkleidungen in Betrieb gesetzt werden W hrend des Z ndvorgangs und oder beim normalen Betrieb die Bildung von Rauch und unverbrannten Stoffen vermeiden Nachstehend werden die Kontroll und oder Wartungsarbeiten zusammengefasst die f r den korrekten Gebrauch und Betrieb des Ofens erforderlich sind 2 3 1 Jahr ee ordrtche orertche ordeniene Monate Reimgung ra vom Art der Reinigung i Kah ordentliche sa A Reinigung Reinigung Reinigung 4 technischen Kundendienst Reinigung durchgef hrt Brennschale n Aschefach kasten n Glasscheibe n Rauchgasw rmetauscher n Abweiser Sammelleitung z n Saugzuggebl se Dichtung T r Glasscheibe n Schornsteinrohr Rauchrohr n 5 1 Reinigung der Brennschale Den Brenntopf herausnehmen und eventuelle R ckst nde die sich in der Brennkammer und im Brenntopfhalter abgelagert haben beseitigen A tale scopo pu essere utilizzato un idoneo aspiratore Diese Arbeit muss t glich vorgenommen werden vor allem wenn sich unverbranntes Material angesammelt hat damit eine optimale Verbrennung gew hrleistet ist da durch die L
174. u chrono 01 activation du chrono 01 activation du chrono on off 02 program jour 01 chrono jour on off 02 start 1 jour heure 03 stop 1 jour heure 04 start 2 jour heure 05 stop 2 jour heure 03 program semaine 01 chrono semaine on off 02 start 1 jour heure 03 stop 1 jour heure 04 lundi prog 1 on off 05 mardi prog 1 on off 06 mercredi prog 1 on off 07 jeudi prog 1 on off 08 vendredi prog 1 on off 09 samedi prog 1 on off 10 dimanche prog 1 on off 11 start prog 2 heure 12 stop prog 2 heure 13 lundi prog 2 on off 14 mardi prog 2 on off 15 mercredi prog 2 on off 16 jeudi prog 2 on off 17 vendredi prog 2 on off 18 samedi prog 2 on off 19 dimanche prog 2 on off 20 start prog 3 heure 21 stop prog 3 heure 22 lundi prog 3 on off 23 mardi prog 3 on off 24 mercredi prog 3 on off 25 jeudi prog 3 on off 26 vendredi prog 3 on off 27 samedi prog 3 on off 28 dimanche prog 3 on off 29 start prog 4 heure 30 stop prog 4 heure 31 lundi prog 4 on off 32 mardi prog 4 on off 33 mercredi prog 4 on off 34 jeudi prog 4 on off 35 vendredi prog 4 on off 36 samedi prog 4 on off 37 dimanche prog 4 on off 04 program week end 01 chrono week end on off 02 start 1 03 stop 1 04 start 2 05 stop 2
175. uale nonch le leggi e le norme Europee Nazionali Regionali Provinciali e Comunali disegni le misure gli schemi ed ogni altra configurazione sono qui riportati solo a scopo esemplificativo Il presente manuale costituisce parte integrante del prodotto verificare che sia sempre a corredo dell apparecchio e in caso di vendita trasferimento ad un altro proprietario o installato in un altro luogo assicurarsi della sua presenza in modo che possa essere consultato in qualsiasi momento In caso di smarrimento o danneggiamento richiedere copia al Centro di Assistenza Tecnico autorizzato in modo che l apparecchio abbia sempre a corredo il proprio manuale Questo simbolo indica la presenza di un messaggio importante a cui prestare particolare attenzione in quanto la mancata osservanza di quanto scritto pu provocare seri danni alla stufa e alle persone Una voce che richiede particolare attenzione evidenziata con il testo in grassetto 1 3 Norme di sicurezza Leggere il manuale d uso e manutenzione prima di installare accedere e manutentare la stufa Eseguire l installazione il collegamento elettrico il collaudo e la manutenzione da un tecnico qualificato e o autorizzato Collegare la stufa ad una canna fumaria a Norma tramite un terminale ispezionabile il collegamento di pi apparecchi pu avvenire solo se viene contemplato dalle Norme locali e concesso dall Organismo di controllo della cann
176. uarantees its products except for parts subject to normal wear in accordance with the current regulations For the warranty terms please contact the importer or the authorised agent who can integrate the compulsory warranty period with an additional period under his sole and exclusive responsibility The product warranty is invalidated for any trouble breakage or accident due to failure to comply with or apply the instructions provided in this manual La soci t COLA garantit ses produits selon les normes actuellement en vigueur l exception des parties qui sont soumises une usure normale Pour les conditions de garantie s adresser a l importateur ou au repr sentant autoris qui pourra accorder une extension de la dur e contractuelle constructeur sous sa propre responsabilit La garantie d choit automatiquement et de plein droit pour tous les dommages ruptures ou incidents caus s par linobservation ou l inapplication des instructions contenues le pr sent manuel Die Firma COLA garantiert ihre Produkte gem den derzeit geltenden Bestimmungen mit Ausnahme der Verschlei teile F r die Garantiebedingungen wenden Sie sich bitte an den Importeur oder an den autorisierten Vertreter der die obligatorische Garantielaufzeit auf ausschlie lich eigene Verantwortung verl ngern kann Die Garantie des Produkts erlischt im Fall von St rungen eines Defekten oder Unf llen die auf die Missachtung der in dieser Anleitung enthaltenen Anleit
177. und Abschalten zu vermeiden jeweils immer nur ein Programm aktivieren Das Tagesprogramm deaktivieren wenn das Wochenprogramm verwendet werden soll mit dieser Einstellung empfiehlt es sich das Wochenendprogramm zu deaktivieren 108 COLA Men ebene 436 i s dc lt 03 SEQE L EH End EASY CRONO HR COLA 4 6 4 Men 04 Sprache w hlen Mit dieser Option kann die gew nschte Dialogsprache unter den im Men verf gbaren Sprachen gew hlt werden und zwar ITALIENISCH FRANZ SISCH ENGLISCH dEUESCH DEUTSCH Dialogfenste 4 6 5 Men 05 Standbybetrieb Bei Wahl des Standbybetriebs wird der Ofen automatisch abgeschaltet nachdem die Raumtemperatur f r eine vorgegebene Zeit ber dem Sollwert geblieben ist Daraufhin kann der Ofen erst dann wieder automatisch eingeschaltet werden wenn die Raumtemperatur unter den in der Parametertabelle angegebenen Wert sinkt Voreinstellung 2 Manuelle Steuerungen vom Bedienpanel oder von der Fernbedienung haben Vorrang vor der Programmierung 4 6 6 Men 06 Summer Mit dieser Option kann der Signalton des Ofens aktiviert oder deaktiviert werden 4 6 7 Men 07 Erste Pelletf llung Die Einstellung ERSTE PELLETF LLUNG gestattet bei ausgeschaltetem oder kaltem Ofen f r die Dauer von 90 Sek eine erste Pelletf llung durchzuf hren Die F llung wird mit der Taste P1 gestartet und mit der Taste P4 abgebrochen Taste P1 En
178. ungen zur ckzuf hren sind 2 EASY CRONO HR COLA 1e AVYERTENER GENERALI 4 7 Telecomando su richiesta 1 1 Imreatiziong 4 7 1 sostituzione batteria 1 2 Come utilizzare il manuale E 13 Norme di sicurezza 4 8 un cronotermostato su 3 esterno ri ci Ha consentit 4 9 Periodo di inattivit fine stagione 1 6 Accessori in dotazione 1 7 Riferimenti normativi 5 ee nrg Tas Tuga chideniiieaziona 5 2 Pulizia contenitore cenere 1 9 Messa fuori servizio della stufa 53 fees del vero e delle fessufe 1 10 Istruzioni per richiesta di intervento e ricambi circolazione aria 2 TRASPORTO ED INSTALLAZIONE 5 4 Pulizia estrattore fumi e camera di 2 1 Imballo movimentazione spedizione e combustione 5 5 Pulizia debimetro 5 6 Pulizia delle ceramiche 5 7 Pulizia raccordo fumi canna fumaria trasporto 2 2 Luogo d installazione posizionamento e sicurezza antincendio 2 3 Presa aria 2 4 Scarico fumi di combustione 2 4 1 Tipologie di installazione 2 5 Controllo posizione braciere e deviatore 2 6 Collegamento elettrico 2 7 Schema elettrico 2 8 Pronto intervento 6 MANUTENZIONE 6 1 Premessa 6 2 Smontaggio rivestimento 6 3 Componenti interni della stufa 6 4 Componenti elettrici 7 RICERCAGUASTI 3 SICUREZZE DELLA STUFA 7 1 Gestione degli allarmi 3 1 Distanza sicurezza da materiali infiammabili 3 2 Sicurezza scarico fumi 3 3 Sicurezza sovrapressione in camera di combustione 3 4 Surriscaldamento termosta
179. ur diff rentiel conform ment aux textes r glementaires et r gles de l art en vigueur Le c ble d alimentation ne doit jamais entrer en contact avec le conduit d vacuation des fum es du po le 2 7 Sch ma lectrique i S assurer que l installation lectrique est r alis avec une connexion de mise la terre du po le et un Secteur 230V Bougie CHANGEUR Extraction des Fumees Encoder pour Extraction des Fumees Sonde de Thermostat g mens ALT Thermostat de securit amp Sonde ALD D bim tre fum es Umees ambiante 69 EASY CRONO HR COLA 2 8 Premi re intervention Il est toujours conseill d installer des quipements anti incendie appropri s En cas d incendie Debrancher immediatement le c ble d alimentation du po le Eteindre le feu avec des extincteurs conformes a la r glementation en vigueur Appeler imm diatement les sapeurs pompiers Ne pas utiliser de jets d eau pour teindre le feu 3 SECURITE 3 1 Distance de securite par rapport aux materiaux combustibles Installer l appareil une distance de s curit minimale par rapport tout mat riau inflammable afin d viter tout risque d incendie conform ment aux indications pr sentes sur la fiche technique du manuel et sur la plaque de l appareil Faire attention au type de sol en cas de mat riaux d licats et inflammables il est recommand d utiliser des plaques de sol en acier ou en verre tremp comme base d ap
180. urs possibles 03 03 29 START PROG 4 Heure d activation ora OFF 03 03 30 STOP PROG 4 Heure de d sactivation ora OFF 03 03 31 LUNEDI PROG 4 on off 03 03 32 MARTEDI PROG 4 on off 03 03 33 MERCOLEDI PROG 4 on off 03 03 34 GIOVEDI PROG 4 on off 03 03 35 VENERDI PROG 4 5 on off 03 03 36 SABATO PROG 4 3 on off 03 03 37 DOMENICA PROG 4 on off 78 EASY CRONO HR COLA 14 96 Activer la programmation WEEK END uniquement apr s a 3 U n 3 avoir d sactiv la programmation hebdomadaire Ge 11 N Pour viter des mises en marche et des extinctions du 5 E nP Aller dans le sous menu PROGRAM WEEK END pour activer d sactiver et pr s lectionner les fonctions du chronothermostat dans le week end fin de semaine samedi dimanche po le non d sir es activer un seul programme la fois D sactiver le programme journalier si l on souhaite E E H E n d utiliser le programme hebdomadaire il est convient Er dans ce cas de d sactiver le programme week end 4 6 4 Menu 04 choix de la langue Cette option permet de s lectionner la langue de dialogue parmi celles propos es dans le menu notamment ITALIEN FRANCAIS nE nu 0 ANGLAIS FrAnCAI 5 ALLEMAND 4 6 5 Menu 05 mode veille stand by Fen tre de dialogue La s lection du mode veille STAND BY _ ON selectione provoque l extinction imm diate du po le lorsque la temp rature ambiante ou la temp rature
181. ustion de passer travers les orifices du creuset de sorte garantir une combustion efficace Le brasier doit parfaitement plaquer sur tout le p rim tre de son support sans laisser aucun interstice pour le passage d air Brasier encrass Brasier propre Support de brasier 81 EASY CRONO HR COLA 5 2 Nettoyage du cendrier Le cendrier amovible est situ directement sous l ensemble brasier et support de brasier Pour le nettoyage ouvrir la porte de foyer et aspirer la cendre et tout autre r sidu de combustion avec un aspirateur approprie A la fin du nettoyage fermer la porte Le d cendrage doit se faire tous les 2 3 jours en fonction de l utilisation du po le 5 3 Nettoyage de la vitre et des fentes d a ration Nettoyer la vitre l aide d un chiffon humide et d un d tergent non abrasif Des fentes ont t pratiqu es entre la vitre la parclose et la porte de foyer dans la partie inf rieure et sup rieure pour permettre a l air de circuler sur la surface int rieure de la vitre Il est important de d barrasser les fentes de la poussi re et des cendres en les nettoyant r guli rement Effectuer donc p riodiquement un nettoyage int rieur sur tout le p rim tre de la vitre 5 4 Nettoyage de l extracteur de fum es et de la chambre de combustion Nettoyer au moins une fois par an la chambre de combustion apr s avoir enlev le couvercle en liminant tous les r sidus de combustion des chicanes int rieures et du
182. utes tentatives r p t es d extinction du po le Nettoyer au moins une fois par an le conduit de fum e et le conduit de raccordement 2 4 1Types d installations Voici quelques d finitions et r gles d installation d un conduit de fum e selon la norme italienne UNI10683 CONDUIT DE CHEMINEE conduit vertical destin collecter et vacuer une certaine hauteur du sol les produits de combustion provenant d un seul appareil et dans les cas autoris s de plusieurs appareils aa Prescriptions techniques du CONDUIT DE CHEMINEE il doit tre de tanche isol et calorifug en fonction de l usage auquel il est destin il doit tre le plus droit possible avec des d voiements dont l angle de ceux ci avec la verticale doit amp tre lt 45 Seggi ni z E E z DA respecter une distance de s curit minimale cart de feu avec les A TT NI z 3 ye naur mat riaux combustibles de la construction par interposition d une lame d air era ou doublage avec des mat riaux isolants il doit avoir de pr f rence une section interne circulaire uniforme sur toute sa hauteur libre et ind pendante il doit si possible comporter une chambre de visite pour collecter les mati res solides suies et les condensats ventuels situ e l embouchure du conduit de raccordement ou carneau CARNEAU ou CONDUIT DE RACCORDEMENT conduit ou l ment de raccordement entre l appareil et le conduit de fu
183. utput 0 02 Flue gas flow Nom output 6 5 g s Red output 2 2 g s Dust emissions Nom output 6 1 mg m Flue draught 10 14 Pa Fume outlet pipe 80 mm Air inlet pipe 50 mm Electrical power supply 230V 50 Hz Electrical power input Ti du 5 Min safety distance rear right left side floor 200 300 0 mm Dimensions mm Hx Wx D 990 x 582 x 499 mm Stove weight 98 kg Hopper capacity 31 litres 22 kg Max heatable volume 212m Pellet consumption can vary according to the type of pellets used and their preservation Considering 35 W h per m3 The building s energy requirement can vary according to the insulation type and climatic zone 34 EASY CRONO HR 990 516 Key A Air grilles B Power cable connection C Combustion air inlet diam 50 mm D Flue pipe connection diam 80 mm E Pellet hopper door 35 COLA 499 0200000000000 0000090090000 nboasaascaasad 000000000000 EASY CRONO HR pellet stove dimensions EASY CRONO HR COLA To open the door fit the handle supplied and turn it clockwise Fire door opening closing handle Opening clockwise Closing anticlockwise 1 5 Permissible use and fuel The pellet stoves work exclusively on pellets in different types of wood complying with Standard DIN plus 51731 or UNI EN 14961 or O Norm M 7135 or having the following characteristics
184. utput from the max value of 5 to a min of 1 with the buttons P5 and P6 Room temperature II Button P6 P5 Button Output set to 4 As well as adjusting the heat output it is also possible to adjust the room temperature directly on the control panel with the buttons P1 and P2 the display shows the current SET temperature status For the ventilation of hot air the stove automatically regulates the speed according to the set heat output Button pe gt SEt bEiP 00 N Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of pellets Make sure the stove is off when loading pellets The pellet hopper lid must always remain closed it must only be opened when loading fuel The bags of pellets must be kept at least 1 5 m from the stove Room temperature When the fume temperature rises the maximum value set the display will show the message MODULA F and the stove starts the modulation of the flame authomatically On the contrary when the temperature goes over 280C the display will show the alarm 446 ALARM HOT FUMI and the stove will start the switch off CI e rc D U procedure om If the STANDBY mode is activated the stove is shut down with a I MARK delay time after reaching the SET temperature Restart occurs D er when the room temperature is lower than a certain fixed value with dL AE ie
185. vono essere opportunamente protette secondo le indicazioni delle specifiche norme vigenti di installazione La distanza minima frontale per la protezione di oggetti infiammabili di 1 5 m Le distanze minime di sicurezza da materiali infiammabili devono rispettare la tabella di seguito riportata A 300 mm B 200 mm C 1500 mm D 200 mm fumaria N Ogni installazione deve prevedere uno spazio tecnico di manovra di facile accesso per le manutenzioni periodiche La stufa amp fornita di 4 piedini regolabili per facilitare il posizionamento in presenza di pavimenti non perfettamente planari per regolare l altezza inclinare leggermente la stufa e ruotare il piedino interessato al livellamento La stufa viene fornita con la sonda ambiente fissata tramite un fascetta sulla parete posteriore della stufa si consiglia la rimozione della fascetta e un posizionamento della sonda ideale per la migliore rilevazione della temperatura nel contesto dell ambiente e della lunghezza del cavo Per una rilevazione lontana dalla stufa si consiglia l installazione di un termostato cronotermostato ambiente 9 EASY CRONO HR COLA Non ammessa l installazione della stufa nelle camere da letto nei bagni e in generale nei locali dove gi installato un altro apparecchio da riscaldamento senza un afflusso di aria indipendente In presenza di pavimento in legno installare una base salva pavimento in conformit alle norm