TS - TSL

image

Contents

1. VEDERE LINK A SEZIONI TS PUMP CROSS SECTION SEE TS CROOS SECTION LINK
2. above that which exists in the casing of the pump L exec Double in series mounting Double in series mounting is needed when cooling liquid and washing under pressure is not avaiable With this mounting the sealed liquid can vary in pressure from the auxiliary one independently while the auxiliary liquid need not be at a higher pressure thar the one existing in the casing of the pump T the pump is supposed to work with cold warm or dangerous liquid cautions have to be kept to prevent any possible accident STARTING THE PUMP I 1 Never run the pump dry 2 Start the pump only after filling completely with liquid through the hole designed for this purpose replace threaded plug after each operation When operating with positive suction head fill the pump by gradually and completely opening the inflow gate valve while keeping open the delivery gate valve to release air Close the delivery gate valve completely and check the pressure controllare che il premitreccia eserciti la giusta pressione contro gli anelli di tenuta Nel caso invece di tenuta meccanica controllare che il coperchietto di chiusura risulti completamente serrato contro il corpo Aprire l alimentazione del liquido di lavaggio della badernao della tenuta meccanica procedendo alla regolazione del flusso 4 Se previsto il raffreddamento della camera di tenuta aprire l alimentazione dell acqua refrigerante regolandone la circolazione 5 Quan
3. must flow in from the upper connection and out from the lower one Stopping the pump Close the delivery gate valve if a check valve is not fitted Switch off the motor PERIODICAL CHECKS AND MAINTENANCE LA cain disconnect the electrical power before any servicing operation Make sure the pump operates in conformity with the range of specified levels of performance and that the absorbed current indicated on the nameplate is not exceeded Pumps with mechanical seal Mechanical seals do not require maintenance Except for possible initial leakage after the first stat up the mechanical seal on the shaft must function without any loss of liquid Do not run the pump when dry When a leak occurs and gradually increases the seal must be replacesd Packing gland When the dripping across the stuffing box becomes excessive and it cannot tightened any further change the seal rings fig 6 and tab 4 Bearing Bearing are lubricated with high quality lithium soap grease Initial lubrication at the factory will be sufficient for 5000 hours operation Perform re lubrication while motor is running The following table 1 indicates the type of bearings of the different pumps and the quantity of grease for re lubrication in grams g tab 1 Ball bearing Q t di grasso Grease Q ty g SMONTAGGIO E RIMONTAGGIO Prima dello smontaggio chiudere le saracinesche in aspirazione e mandata Per lo smontaggio e il rimontaggio
4. precautions involves a risk of electric shock Instruction for installation and use General Installation Operation Starting the pump Periodical check and maintenance Disassembly and reassembly Seals replacement Declaration of conformity CE Via Segr 11 A 43100 Parma Italia Tel 39 0521 606285R a Fax 39 0521 606278 E mail sr salvatorerobuschi com GENERALIT Garanzia In conformit alle ns condizioni di fornitura facciamo presente che l inosservanza delle norme seguenti potr causare un imperfetto funzionamento della pompa e produrre inconvenienti di cui la casa costruttrice declina ogni responsabilit La garanzia delle caratteristiche idrauliche e meccaniche della pompa definita nelle condizioni relative alle condizioni contrattuali di vendita Collaudi Le pompe di ns produzione sono accuratamente collaudate su apposito banco onde determinare la perfetta tenuta idraulica di tutti i componenti della pompa la prova di pressione pari a quella massima di esercizio l esatta rispondenza delle caratteristiche sia idrauliche che meccaniche alle prestazioni richieste Condizioni di impiego Per liquidi carichi anche leggermente abrasivi non aggressivi per i materiali della pompa INSTALLAZIONE Trasporto Sollevare e trasportare il gruppo pompa motore come indicato in fig 1 GENERAL Guarantee In accordance to our supply conditions we inferm you that if the follow
5. the motor plate plus 5 It will be the local responsible task to make sure this earthing is carried out first and all the installation operations are perfomed in compliance with the applicable regulation Coupling guard According to the security rules the pumps can work only if the coupling is correctly protected If not included in the supplyimg it must be installed by the final user OPERATION a Check that the pump rotates freely by hand b Check that the direction of rotation shown on the motor is the same as shown on the pump c Grease lubrificated bearings at the time of delivery the bearings are preliminarily greased with high quality grease d Auxiliary fittings connect where necessary pipes for flowing barring heating or cooling A exec Single mechanical seal with throat bushing If the stuffing box is not connected to the pump casing flow the mechanical seal with a consistent liquid at the pressure higher that of the pumped liquid Place a regulation valve at the inlet of the stuffing box C exec Double back to back mounting Double back to back mounting is advisable for adhesive and hot liquids those with a tendency to form crystals gas etc With this mounting contact is avoided between the spring and the pumped liquid The washing and cooling is obtained by means of the circulation of an auxiliary liquid compatible with the sealed liquid this liquid must be at a pressure of at least 0 5 Bar
6. Pompe centrifughe a vortice TS Torque flow centrifugal pumps TSL Manuale di uso e manutenzione Operating and maintenance manual AVVERTIMENTI PER LA SICUREZZA DELLE PERSONE E DELLE COSE 1 AVVERTENZA Avverte che la mancata osservanza della prescrizione comporta un rischio di danno alla pompa o all impianto O ATTENZIONE Avverte che la mancata osservanza della prescrizione comporta un rischio di danno alle persone e o alle cose A PERICOLO Avverte che la mancata osservanza della prescrizione comporta un rischio di danno molto grave alle persone e o alle cose AN PERICOLO Avverte che la mancata osservanza della prescrizione comporta un rischio di scosse elettriche Istruzioni per l installazione e l uso Generalit pag 1 Installazione x 1 Esercizio n 3 Avviamento si 3 Controlli e manutenzione s 4 Smontaggio e rimontaggio i 4 Sostituzione delle tenute s 5 Dichiarazione di 5 conformit O SALVATORE EEA ROBUSCHI d POMPE PARMA Salvatore Robuschi amp C S r l GB SAFETY PRECAUTION WARNING Warns that failure to observe the precautions involves the risk of damaging the pump and or the plant 3 CAUTION Warns that failure to observe the precautions involves the risk of damaging persons and or things gt DANGER Warns that failure to observe the precautions involves a very serious risk of damage to persons and or things gt DANGER Warns that failure to observe the
7. aft seal Dia comando opposto comando Pump size Ball bearing Ball bearing Le L o c D S N D S D S N D S TS 30 6305 2RS 6403 32 30 28 32 TS 40 3 40 8 3305 6305 30 30 28 32 TS 50 3 50 8 3305 6305 30 30 28 32 TS 40 9 40 12 3206 6305 32 28 32 TS 50 9 50 10 3206 6305 32 28 32 DISASSEMBLY AND REASSEMBLY Close the suction and delivery gate valves and drain the pump casing before dismantling the pump Be sure to cut off power source before beginning disassembly For disassembly and reassembly see the sectional assembly drawing Ma working with dangerous liquids follow the due warnings SEALS REPLACEMENT Packing gland Use seal ring suitable to the liquid that must be pumped The seal rings have to be suitable cut fig 5 It is necessary to alternate the gasket slits so that they don t fit each other fig 6 Mechanical seals Stationary part mounting make sure that the bevel or chamfer and the housing are absolutely clean and free from ragged edges and traces of working Damp the housing and the stationary gasket with alcohol glycerine or a compatible liquid Press the stationary part into the housing using a suitably covered stopper mounted on the spindle of a sensitive drill or small press Rotary part mounting make sure that shaft is smooth clean and free from sharp edges Polish the shaft if necessary with a fine abrasive cloth about 400 grains even if it has been ground A
8. aggio sotto pressione Con questo montaggio il liquido pompato pu variare di pressione indipendentemente da quello ausiliario mentre quest ultimo non deve essere a pressione superiore a quella esistente nel corpo della pompa ic la pompa funzioni con liquidi freddi caldi e o pericolosi devono essere prese le precauzioni necessarie per evitare qualsiasi incidente AVVIAMENTO 1l Evitare assolutamente il funzionamento a secco 2 Avviare la pompa solo dopo averla riempita completamente di liquido Con il funzionamento sotto battente riempire la pompa aprendo lentamente e completamente la saracinesca nel tubo di arrivo tenendo aperta la saracinesca in mandata per fare uscire l aria Chiudere completamente la saracinesca in mandata e controllare la pressione del battente per accertarsi che la pressione massima non sia superiore a quella tollerata dalla pompa 3 Nel caso in cui la pompa sia fornita con tenuta a baderna AN Electrical connection Electrical connection must be carried out by a qualified electrician in accordance with local regulation Make sure that the suppy voltage corresponds to the voltage on the motor plate The motor protection switch or the therminal relay must be set for the current indicated on the motor plate Provide a device to disconnect each phase from the supply with a break of 3mm between the contacts in the open position The motor protection switch or the thermal relay be set at the current indicated on
9. do la pompa provvista di camere di riscaldamento alimentate con vapore occorre che questo affluisca dagli attacchi superiori 6 Avviare la pompa con saracinesca di mandata chiusa Aprire poi lentamente la saracinesca in mandata regolando il punto di funzionamento entro i limiti indicati in targa Verificare che il senso di rotazione corrisponda a quello indicato dalla freccia sul corpo pompa in caso contrario invertire fra loro i collegamenti di due fasi Arresto Chiudere la saracinesca in mandata in assenza di valvola di ritegno Chiudere la saracinesca in aspirazione in assenza di valvola di fondo Arrestare il motore CONTROLLI E MANUTENZIONE lac prima di ogni intervento di manutenzione togliere l alimentazione elettrica Controllare che l elettropompa lavori nel suo campo di prestazioni e che non venga superata la corrente assorbita indicata in targa Pompe con tenuta meccanica La tenuta meccanica non richiede manutenzione Salvo possibili perdite iniziali dopo il primo avviamento la tenuta meccanica sull albero deve funzionare senza perdite Evitare il funzionamento a secco Quando si manifesta una perdita che aumenta gradatamente occorre procedere alla sostituzione della tenuta Pompe con tenuta a treccia Nelle pompe con tenuta a treccia necessario vi sia un leggero gocciolamento Quando le perdite per gocciolamento attraverso il premistoppa diventano eccessive e non si ha pi la possibilit di effettuar
10. e un ulteriore serraggio occorre procedere alla sostituzione degli anelli di tenuta vedi fig 6 e tab 4 Supportazione I cuscinetti sono lubrificati con grasso di qualit al sapone di litio La prima lubrificazione eseguita in fabbrica pu bastare per 5000 ore Eseguire la rilubrificazione con motore in moto La tabella 1 seguente indica i tipi di cuscinetti delle diverse pompe e la quantit di grasso per la rilubrificazione in grammi Cuscinetto Q t di grasso Grease Q ty g of the suction head to make sure the maximum final pressure must not be superior to the one borne by the pump 3 Start the pump with the deluvery gate valve closed Then slowly open the discharge gate valve and proceed to regulate the pump duty point within the limits indicated on the nameplate Make sure the direction of rotation is as shown by the arrow on the pump casing If rotation is in the opposite direction reverse the connections of two phases 4 If the pump is supplied with a packing gland check that the gland exerts the right pressure against the seal rings in case of mechanicals seals check that the cover is perfectly closed against the casing Open the feeding of the liquid for washing of the packing or of the mechanical seal and regulate the flow 5 If cooling of the seal chamber is provided open the feeding of the cooling water rigulating its circulation 6 When the pump is provided with steam preheating chambers the steam
11. fter having damped the shaft with alcohol glycerine etc mount the rotary part turning the seal with a gentle motion in the direction to the winding of the spring Make sure that the two lapped faces come into contact It is harmful tu put grease oil and other similar substances between the faces of the seal which must be absolutely clean tab 3 Anelli baderna Packing ring Grandezza pompa Dia albero Dimensioni della Anello baderna N anelli camera Pump size Shaft seal dia Chamber dim Packing ring N packing ring Dia 1 TS 30 x TS 40 3 40 8 30 50 60 50 10 5 4 TS 50 3 50 8 30 50 60 50 10 5 4 TS 40 9 40 12 30 34 50 60 50 10 8 6 4 TS 50 9 50 10 30 34 50 60 50 10 8 6 4 DICHIARAZIONE DI CONFORMITA Noi Salvatore Robuschi amp C dichiariamo sotto la nostra esclusiva responsabilit che le pompe TS TSL sono conformi a quanto richiesto dalle direttive 89 392CEE 94 368 CEE 93 68 CEE quando utilizzate in osservanza alle prescrizioni contenute nel manuale di istruzioni L amministratore DECLARATION OF CONFORMITY We Salvatore Robuschi amp C declare that our pumps TS TSL are constructed in accordance with directives 89 392 CEE 91 369 CEE 93 68 CEE and assu me full responsability for conformity with the standards laid down therein wen operated according to their intended purpose as described in the operated handbook The legal representative SEZIONE POMPA
12. ientemente rigida da mantenere l allineamento del gruppo Il tutto si ottiene con una fondazione in calcestruzzo prevista con appositi pozzetti come indicato in fig 2 ove inserire e bloccare i bulloni di fondazione con la colata finale di calcestruzzo E necessario appoggiare il gruppo sulla fondazione interponendo in prossimit dei bulloni degli spessori e sistemati in modo che il gruppo risulti in posizione orizzontale Controllare con una livella sull albero e sulla flangia di mandata Fare la colata di cemento e dopo che il cemento ha fatto presa minimo 48 ore serrare uniformemente i bulloni di fondazione Allineamento pompa motore Togliere la protezione del giunto ed allentare le viti del sostegno supporto per evitare che causino tensioni o spostamenti dell altezza d asse Con calibro per spessori controllare l allineamento angolare verificando che la distanza tra i semi Baseplate The pump which is supplied with motor coupling and baseplate is assembled in our firm with the utmost care Before the final installation it is necessary to check that no damage occured in transit The pump is to be entrusted for connection to skilled staff a faulty connection can cause wrong working and a premature wear and tear of the coupling and of the pump itself Foundation The foundation has to be strong and rigid enough both to damp vibrations and to hold the alignement of the unit which is usually obtained by means of a concrete foundation eq
13. ing instructions are not followed the pump could start to malfunction or worse damages could occur for which we would assume no responsability The hydraulic and mechanical characteristics of the pump can be guaranteed only for operation under the conditions specified the order acknowledgement Tests All the pumps of our production undergo accurate testing on an appropriate testing desk to certify the perfect hydraulic seal of all the parts forming the pump for this reason hydrostatic pressing with test pressure of 1 5 times operational one is carried out the complete conformity of the hydraulic and mechanical characteristics with the requested functional conditions LI Operating conditions Suitable for dirty liquids even if slightly abrasive provided these are not corrosive for the pump INSTALLATION Transport Lift and trasport the pump motor units as indicated in fig 1 Basamento La pompa fornita con motore giunto e basamento assemblata con la massima accuratezza presso le ns officine Prima della definitiva installazione necessario controllare che non siano intervenute avarie durante il trasporto La pompa fornita ad albero nudo dovr essere affidata per l accoppiamento a personale specializzato un assemblaggio difettoso pu dare adito ad incidenti di funzionamento e ad una usura prematura della macchina Fondazione La fondazione deve essere sufficientemente robusta da assorbire la vibrazioni e suffic
14. nto la funzione di trasmettere la coppia motrice alla pompa Tubazioni di aspirazione e mandata Il tubo aspirante che non deve mai essere di diametro inferiore a quello della bocca di aspirazione della pompa dovr essere dimensionato in funzione delle condizioni di aspirazione e tenere conto delle caratteristiche del prodotto e della temperatura E necessario assicurarsi che le giunture della tubazione di aspirazione siano a perfetta tenuta onde evitare l entrata di aria nelle stesse Inoltre la tubazione di aspirazione nei tratti orizzontali dovr avere una pendenza positiva verso la pompa in modo da evitare il formarsi di sacche d aria Per funzionamento con battente positivo la tubazione deve essere discendente verso la pompa Quando la pompa lavora con dislivello negativo in aspirazione necessario installare una valvola di fondo all estremit della tubazione onde mantenere l adescamento Installare anche una valvola di non ritorno sulla tubazione di mandata per proteggere la pompa da eccessive contropressioni e dalla rotazione inversa dopo ciascun arresto fig 3 Fissaggio tubazioni Le tubazioni di aspirazione e di mandata devono essere sostenute indipendentemente dalla pompa Le stesse devono essere posizionate in modo che flange e controflange combacino perfettamente evitando la trasmissione di tensioni sulla pompa Inserire anche un soffietto di compensazione per assorbire sollecitazioni o dilatazioni dovute alla temperat
15. osservare la costruzione sul disegno in sezione A presenza di liquidi pericolosi adottare le dovute precauzioni SOSTITUZIONE DELLE TENUTE Tenuta a treccia E necessario utilizzare anelli di tenuta adatti al liquido da pompare Gli anelli devono essere tagliati in modo conveniente vedi fig 5 E necessario sfalsare i tagli delle guarnizioni in modo che non combacino l uno con l altro fig 5 Tenute meccaniche Montaggio parte fissa assicurarsi che lo smusso o raccordo di invito e l alloggio siano perfettamente puliti e privi di bave e segni di lavorazione Inumidire l alloggio e la guarnizione con alcool glicerina o liquido compatibile Premere nell alloggio la parte fissa usando un tampone opportunamente rivestito montato sul fuso di un trapano sensitivo o pressetta a mano Montaggio parte rotante Assicurarsi che l albero sia liscio pulito e privo di spigoli taglienti Lucidare eventualmente l albero con tela abrasiva fine grana 400 ca anche se rettificato Dopo aver umettato l albero con alcool glicerina ecc montare la parte girante ruotando la tenuta con leggero moto contrario al senso di avvolgimento della molla Assicurarsi che le due facce lappate siano venute a contatto E dannoso interporre grasso olio o altre sostanze simili tra le facce della tenuta che devono essere scrupolosamente pulite tab 2 Cuscinetti Ball bearing Grandezza pompa Cuscinetto lato Cuscinetto lato Dia tenuta Sh
16. to In conformit alle norme antinfortunistiche si deve fare funzionare la pompa solo se il giunto opportunamente protetto Se la fornitura non prevede il coprigiunto esso deve essere messo in opera a cura dell utente ESERCIZIO a Controllare che la pompa ruoti liberamente a mano b Controllare il senso di rotazione segnato sulla pompa c Cuscinetti lubrificati a grasso i cuscinetti all atto della spedizione sono preventivamente ingrassati con grasso di qualit d Attacchi ausiliari Collegare ove siano contemplate le tubazioni di flussaggio sbarramento riscaldamento o raffreddamento Esec A Tenuta singola con bussola di fondo Se non collegato al corpo pompa flussare la tenuta con liquido compatibile a pressione superiore a quello esistente nel corpo pompa Installare una valvola di regolazione all ingresso della sede tenuta esec C Tenute doppie contrapposte Il montaggio doppio contrapposto indicato per liquidi adesivi caldi aventi tendenza a formare cristalli gas ecc Con questo montaggio si evita il contatto molla liquido pompato Il raffreddamento lavaggio ottenuto mediante circolazione di liquido ausiliario compatibile con il liquido pompato tale liquido deve essere ad una pressione di almeno 0 5 Bar superiore a quella esistente nel corpo della pompa esec L Tenute doppie in serie Il montaggio doppio in serie serve quando non si ha a disposizione liquido di raffreddamento e lav
17. uipped with small wells where foundation bolts are to be inserted and covered with final concrete cast Place the unit on the foundation and fit some shims or metal wedges having a small taper close to the foundation bolts so as to have checking with a water level on the shaft or delivery flange fig 2 Cast concrete and when concrete has hardened at least after 48 hours tighten the foundation bolts Aligning the pump motor Remove the coupling protection and unscrew the screws of the support foot to avoid any stresses or variations in the axis heitht use a thickness gauge or comparator to check the angular alignment then make sure that the distance between the semi couplings is the same the whole pheriphery long Check the parallel alignment with a ruler or comparator The unit is aligned giunti sia uguale lungo tutta la periferia Controllare quindi l allineamento parallelo con la riga Il gruppo allineato quando la distanza tra ciascun albero e la riga appoggiata sul giunto la stessa su quattro punti diametralmente opposti la massima deviazione assiale e radiale tra i due semi giunti non deve eccedere 0 1 mm vedi fig 2 Per eventuali correzioni allentare o togliere le viti per spostare i piedi sulla base ed aggiungere ove occorre lamierini o rosette calibrate Un giunto non ha la possibilit di compensare eventuali irregolarit di montaggio del gruppo ma ha solta
18. ura Strumenti di controllo Installare un manometro sulla tubazione di mandata e un manovuotometro su quella di aspirazione onde consentire un controllo efficace only when the distance between each shaft and the ruler placed on the coupling is the same from each one of 4 diametrally opposed points The maximum axial and radial deviation between the two semi coupling cannot exceed 0 1 mm fig 2 For any correction loosen and take off the scews where required in order to move the feet on the base and if necessary fit additional calibrated steels or wash fig 2 The coupling cannot compensate eventual assembly irregularities of the group but it has the sole function of transmitting torque to the pump Suction and delivery pipes The suction pipe which internal diameter should never be smaller than the suction port should be arranged in accordance with the suction conditions Bear in mind that pump maximum theoretical suction lift is reduced in addition to the NPSHr required by the pump by the temperature Make sure that connection in the suction pipe are perfectly airtight Moreover in its horizontal sections the suction pipe must have a positive slope towards the pump and any pipereduction has to be eccentric to avoid that air pockets occur inside the pipeline Should the pump run with a negative slope in the suction pump apply a foot valve at the end of the pipe to permit and keep priming of the pump A check val
19. ve must be fitted in the delivery pipe to protect the pump from too high counterpressures or reverse rotation after each stopping For working with positive suction head the pipe must be lowered down towards the pump fig 4 Pipe clamping Suction and delivery pipes have to be supported indipendently of the pump but as close to it as possible Be sure that the pipes are installed so as permite the perfect mating of flanges and couterflanges which avoids stress transmission to the pump A compensation bellows is also necessary to absorb expansions caused by hot liquids Checking For a constant and efficient check it is wise to fit a gauge on the discharge pipe and a vacuum gauge on the suction pipe A Allacciamento elettrico Il collegamento elettrico deve essere eseguito da personale esperto e secondo le disposizioni locali Assicurarsi che la tensione della linea di alimentazione corrisponda a quella del motore Sar cura del responsabile dell installazione in loco assicurarsi che il collegamento di terra sia eseguito per primo e che tutto l impianto sia eseguito in conformit alle norme vigenti Installare un dispositivo per la onnipolare disinserzione della rete con distanza di apertura dei contatti di almeno 3 mm di targa del motore Per la protezione del motore montare un interruttore magneto termico o un rel termico che devono essere tarati alla corrente di targa del motore maggiorato del 5 W Coprigiun