1. shown in Figure 6 which indicates the correct and incorrect smoke detector locations concerning this problem AIR ENTRY BEDROOM O BEDROOM LIVING ROOM O CORRECT LOCATION XW INCORRECT LOCATION Figure 6 recommended smoke detector locations to avoid air streams with combustion particles e In damp or very humid areas or near bathrooms with showers Moisture in humid air can enter the sensing chamber then turns into droplets upon cooling which can cause nuisance alarms Install smoke detectors at least 10 feet 3 meters away from bathrooms e In very cold or very hot areas including unheated buildings or outdoor rooms If the temperature goes above or below the operating range of smoke detector it will not work properly The operating temperature range for your smoke detector is 40 F to 100 F 4 C to 38 C e In very dusty or dirty areas dirt and dust can build up on the detector s sensing chamber to make it over sensitive Additionally dust or dirt can block openings to the sensing chamber and keep the detector near fresh air vents or very drafty areas like air conditioners heaters or fans fresh air vents and drafts can drive smoke away from smoke detectors e Dead air spaces are often at the top of a peaked roof or in the corners between ceilings and walls Dead air may prevent smoke from reaching a detector See Figures 4 and 5 for recommended mounting locations e In insect infested areas If insects ent
2. 08410 00 4 4 inch 10cm Minimo CENTRO DEL MAI QU i 6 inch 15cm SOFFITTO STO Max MIGLIOR POSIZIONE lt 15 POSIZIONE ACCETTABILE Figura 4 Posizioni raccomandate per installare il rilevatore RILEVATORE 9 FEET 2 75 mt DISTANZA ORIZZONTALE DAL VERTICE Figura 5 Modalit d installazione con soffitto inclinato ATTENZIONE Un allarme precoce del rilevamento del fuoco si ottiene grazie all installazione di un sistema di rilevamento di fuoco in ogni camera da letto e le varie zone della casa come segue 1 Un rilevatore di fuoco installato in ogni camera da letto separata vicino ma fuori dalla stanza e 2 un rilevatore installato nel salone sala da pranzo cucina corridoi solai gabinetti ripostiglio e zone di stoccaggio ed i garage annessi Per informazione conforme allo standard NFPA 74 Sezione 2 4 afferma 2 4 1 1 rivelatori di fumo e calore devono essere installati al di fuori di ogni zona notte nelle immediate vicinanze delle camere da letto e in ogni area supplementare compresi scantinati Le disposizioni del 2 4 1 1 rappresentano il numero minimo di rilevatori richiesti dalla presente norma Si raccomanda che il padrone di casa prenda in considerazione l uso di rivelatori aggiuntivi per una maggiore protezione per le aree separate da una porta dalle aree protette dal rivelatore Le ulteriori aree consigliate sono soggiorno sala da pranzo camera da letto s cucina man
3. 410 00 SMK 500 Wireless SMK 500D Independent Introduction Our photoelectric smoke detector is designed to sense smoke that comes into the detector chamber It does not sense gas heat or flame This smoke detector is designed to give early warning of developing fires by giving off the alarm sounds from its built in alarm horn It can provide precious time for you and your family to escape before fire spreads However the smoke detector makes such pre warning of fire accident possible only if the detector is located installed and maintained properly as described in this User s Manual WARNING This smoke detector is designed for use in a single residential unit only which means that it should be used inside a single family home or apartment It is not meant to be used in lobbies hallways basements or another apartment in multi family buildings unless there are already working detectors in each family unit Smoke detectors placed in common areas outside the individual living unit such as on porches or in hallways may not provide early warning to residents In multi family buildings each family living unit should set up its own detectors WARNING This detector is not meant to be used in non residential buildings warehouses industrial or commercial buildings and special purpose non residential buildings require special fire detection and alarm systems This detector alone is not a suitable substitute for complet
4. ART 35 08410 00 Rilevatore di fumo fotoelettrico Manuale d istruzioni O Ideale per l installazioNe in qualsiasi area ART 35 08410 00 SMK 500 Wireless SMK 500D Indipendente Introduzione Il nostro rilevatore di fumo fotoelettrico progettato per rilevare la presenza di fumo in un determinato ambiente Non rileva gas il calore o fiamme Questo rivelatore stato progettato per segnalare anticipatamente lo sviluppo di fiamme attraverso la segnalazione acustica integrata nell apparecchio ATTENZIONE Questo rilevatore di fumo progettato per il solo utilizzo in una unit residenziale singola ovvero deve essere utilizzato all interno di un abitazione singola o di un appartamento Non destinato per un utilizzo in atri corridoi seminterrati in appartamenti in condomini salvo se sono gi installati in modo indipendente altri rilevatori di fumo in ogni nucleo familiare esistente rilevatori di fumo installati in locali ad uso comune esterni all unit familiare come verande o corridoi potrebbero non avvertire a tempo i residenti dell edificio Nei edifici residenziali multifamiliari ogni appartamento individuale deve essere equipaggiato di rilevatori di fumo indipendenti ATTENZIONE Questo rilevatore di fumo non progettato per un utilizzo in zone non residenziali capannoni edifici industriali o commerciali luoghi a fini non residenziali devono avere rilevatori di fuoco specializzati e sis
5. a PAGINA 8 DI 8 Technical Specifications Power Supply DC 9V 6F22 battery x 1 Standby Current lt 5yA Alarm Current lt 15mA LED Frequency in Working State Once every 32 sec LED Frequency in Alarming State Once every 0 62 sec Low Battery State Beep once with a LED flash per 60s last for 30 days Operation Condition Temperature 10 C 55 C Relative humidity lt 95 no condensing Monitoring Area 20m Alarm Decibel 85dB 3m Radio Frequency 315MHz 433 92MHz or 868MHz Transmitting Distance lt 80mt in open area SMK 500 Housing Material ABS Plastic Dimensions LxWxH 102x102x31 mm A G User information ex art 26 D 49 2014 The symbol labelled on the appliance Annex IX D 49 2014 indicates that the rubbish is subject to separate collection and it has been placed on the Italian market after the December 31 2010 The user must therefore assign or have collected the rubbish to a treatment facility according to indications by the local administration or hand it over to the reseller in exchange for an equivalent new product The separate collection of the rubbish and the subsequent treatment recycling and disposal operations encourage the production of appliances made with recycled materials and reduce negative effects on health and the environment caused by improper treatment of rubbish In the case of very small WEFE no external dimension more than 25 cm the user is eli
6. allazione sia stabile con un pannello di controllo ex STEEL GO NOT PAINS LED ROSSO PULSANTE DI TEST Il rilevatore di fumo 35 08410 00 pu essere utilizzato individualmente o abbinato ad un pannello di controllo per integrare un sistema di allarme via modulo wireless del rilevatore 1 Assicurarsi che il pannello di controllo sia in modalit learning abbinamento 2 Premere il tasto test del rilevatore per 3 secondi due beep sonori STAFFA DI FISSAGGIO RILEVATORE confermeranno l abbinamento Il pannello di controllo emetter anche lui un beep per indicare che l operazione stata effettuata con successo Fase test Premere il tasto test per 3 secondi il pannello di controllo si metter in allarme automaticamente Indicatore LED Rosso o i Il rilevatore di fumo equipaggiato di un indicatore LED rosso situato presso il tasto Test Quando l indicatore LED rosso lampeggia una volta ogni 32 secondi significa che il rilevatore in condizione di e funzionamento normale Quando il LED rosso acceso in modo Per aprire il coperchio della batteria ed installarla procedere nel continuo e simultaneamente il cicaclino interno del rilevatore emette modo seguente un beep acustico questo indica che il rilevatore sta rilevando una condizione di allarme I I Ill NW i ij 1 Per azionare il rilevatore di fumo si richiede una batteria 2 Aprir
7. are che il rilevatore di nuovo in modalit di funzionamento normale ATTENZIONE La funzione di tacitazione non disattiva il funzionamento del rilevatore solo temporaneamente meno sensibile al fumo Per ragioni di sicurezza se l apparecchio rileva del fumo abbastanza denso da raggiungere la soglia di allarme si attiver l allarme Se non si conosce l origine del fumo verificare la situazione prima di pensare ad un falso allarme sistemi di rilevazione fumo sono un importante aiuto per ridurre danni infortuni e rischi di morte NOTA Non scollegare l alimentazione o estrarre la batteria dal rilevatore La sua abitazione non sar pi protetta dal fuoco Questo rilevatore dotato di una spia batteria scarica e di un avvisatore acustico Emette simultaneamente segnalazioni acustiche ad intervalli di 1 minuto e ha una durata residua di almeno 30 giorni prima che le batterie si scarichino completamente Quando si sente questo segnale di avvertimento sostituire le batterie Se invece il rilevatore emette suoni acustici intermittenti e la spia Led si accende ad intervalli di un minuto significa che deve essere immediatamente riparato o sostituito Manutenzione del rilevatore di fumo Per mantenere il rivelatore in buone condizioni di funzionamento effettuare un test di funzionamento con cadenza settimanale Consultare la sezione Test del rilevatore di fumo Sostituire la batteria del rilevatore appena eme
8. are rilevatori di fumo alla fine del corridoio che porta alle camere da letto se risulta pi lungo di 12 mt e Installare il rilevatore di fumo all interno della camera da letto specialmente se si ha l abitudine di dormire con la porta chiusa gi che il fumo pu rimanere bloccato dalla porta chiusa e l allarme posizionato all entrata potrebbe non svegliarlo con la porta chiusa SALA DA PRANZO CUCINA CAMERA CAMERA DALETTO DA LETTO O O O SOGGIORNO O CAMERA DA LETTO INSTALLAZIONE A BASSA SICUREZZA O INSTALLAZIONE AD ELEVATA SICUREZZA Figura 1 Dove posizionare rivelatori di fumo nel caso di residenze con un unica area da notte CAMERA DA LETTO O SOGGIORNO O CUCINA SALOTTO O CAMERA DA LETTO CAMERA DA LETTO INSTALLAZIONE A BASSA SICUREZZA INSTALLAZIONE AD ELEVATA SICUREZZA Figura 2 Dove posizionare rivelatori di fumo nel caso di residenze con pi di un area da notte CAMERA DA LETTO CAMERA h CAMERA DALETTO DA LETTO SEMINTERRATO INSTALLAZIONE A BASSA SICUREZZA Figure 3 Posizionamento di rivelatori di fumo in residenze a pi piani e Installare i rilevatori di fumo in un semiinterrato in fondo alla tromba delle scale e Installare i rilevatori di fumo al secondo piano in cima alla tromba delle scale tra il primo ed il secondo piano e Assicurarsi che nessuna porta o altri ostacoli blocchino il percorso del fumo verso il rilevator
9. ato nella figura 6 indicando i luoghi corretti e non corretti dove posizionare il rilevatore CORRENTE D ARIA CAMERA DA LETTO O ENTRATA ARIA CAMERA DA LETTO SOGGIORNO O UBICAZIONE CORRETTA W UBICAZIONE ERRATA Figura 6 Posizioni raccomandate dove installare il rilevatore per evitare correnti di aria con particelle di combustione e In presenza di bagnato o aree molto umide o vicino a bagni con doccia La condensa pu entrare nella camera di rilevamento quindi creare gocce di raffreddamento capaci di causare falsi allarmi Installare il rilevatore al meno a 3 metri da bagni e In zone molto fredde o molto calde inclusi edifici non riscaldati o stanze esterne Se la temperatura maggiore o minore dell intervallo di rilevamento del rilevatore di fumo questo non funziona Rispettare l intervallo di rilevamento da 4 C 38 C 40 F 100 F e In prossimit di condotti di ventilazione o zone con correnti d aria come condizionatori radiatori o ventilatori Questi condotti di ventilazione e correnti d aria potrebbero allontanare il fumo dai rivelatori e In zone di aria morta Sono spesso localizzate a livello del tetto o negli angoli formati dal soffitto con il muro L aria stagnata potrebbe impedire al fumo di arrivare al rilevatore Riferirsi alle figure 4 e 5 per una corretta scelta del luogo di installazione e In zone infestate da insetti Pu accadere che questi insetti entrino nella camera di rilevazione causand
10. camente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto ART 35 08410 00 Installing Your Smoke Detectors Read Locations to Install Your Smoke Detectors and Locations not to Install Your Smoke Detectors section in the manual first and then decide where to install the detector Please follow these steps to install your smoke detector 1 At the place where you are going to install the detector draw a horizontal line six inches long 2 Remove the mounting bracket from your unit by rotating it counterclockwise 3 Place the bracket so that the two longest hole slots are aligned on the line In each of keyhole slots draw a mark to locate a mounting plug and screw 4 Remove the bracket 5 Using a 3 16 inch 5mm drill bit drills two holes at the marks and insert plastic wall plugs Put the detector away from getting plaster dust on it when you drill holes for mounting 6 Using the two screws and plastic wall plugs all supplied attach the bracket to the wall 7 Line up the slot of the bracket and the detector Push the clockwise to fix it into place Pull outward on the detector to make sure it is securely attached to the mounting bracket BRACKET DETECTOR SCREWS P lt LL SCREWS 8 The steps to open the battery cover and to install the battery are listed as follows 1 To power smoke detector requires a ba
11. e e Installare rilevatori di fumo addizionali in sala da pranzo salotto attico camere di stoccaggio e ripostiglio e Installare i rilevatori di fumo il pi vicino possibile al centro del soffitto Se non possibile installare il rilevatore sul soffitto assicurandosi che non sia pi lontano di 10 cm da ogni muro o angolo come indicato nella figura 4 e Se l installazione sul soffitto non possibile installare il rilevatore di fumo sul muro a 10 15 cm dal soffitto come indicato nella figura 4 e Se alcune stanze presentano un soffitto inclinato o non piano installare il rilevatore di fumo a 90 cm dal punto pi alto del soffitto come indicato nella figura 5 ELCART DISTRIBUTION SPA via Michelangelo Buonarroti 46 20093 Cologno Monzese Milano ITALY Tel 39 02 25117310 Fax 39 02 25117610 sito internet www elcart com e mail info elcart it La divulgazione dei dati contenuti in questa scheda da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto ART 35
12. e fire detection systems for places where many people live or work such as hotels or motels The same is true of dormitories hospitals nursing homes or group homes of any kind even if they were once single family homes Please refer NFPA 101 the Life Safety Code NFPA71 72A 72B 72C 72D and 72E for smoke detector requirements for fire protection in buildings not defined as households Locations to Install Your Smoke Detectors Smoke detectors should be installed in accordance with the NFPA Standard 74 National Fire Protection Association Battery march Park Quincy MA 02169 For complete coverage in residential units smoke detectors should be installed in all rooms halls storage areas basements and attics in each family living unit Minimum coverage is one detector on each floor and one in each sleeping area and attics in each family living unit ELCART Manuale di istruzioni Scheda tecnica PAGINA 5 DI 8 Here we have useful tips for you e Install a smoke detector in the hallway outside every separate bedroom area as shown in Figure 1 Two detectors are required in homes with two bedroom areas as shown in Figure 2 Install a smoke detector on every floor of a multi floor home or apartment as shown in Figure 3 e Install a minimum of two detectors in any household Install a smoke detector inside every bedroom Install smoke detectors at both ends of a bedroom hallway if the hallway is more than 40
13. e il compartimento batteria ed installare la batteria all interno assicurarsi che e siano allineati contemporaneamente 3 Chiudere il vano batteria fermamente fino allo scatto in posizione Test del rilevatore di fumo Per assicurarsi che il rilevatore di fumo stia funzionamento correttamente testare settimanalmente il sensore premendo il tasto Test fino all emissione del beep di conferma Per ottenere il beep sonoro ci vogliono circa 5 secondi Questo l unico modo per verificare se il rilevatore funziona correttamente Se il rilevatore non emette nessun suono acustico significa che deve essere immediatamente riparato o sostituito BATTERIA ATTENZIONE Evitare assolutamente di utilizzare una fiamma per testare il rilevatore possibile danneggiare il prodotto e la sua abitazione Utilizzare unicamente il tasto test ATTENZIONE Il rilevatore dotato di un meccanismo sul coperchio in modo da evitare che si chiuda qualora la batteria non sia installata ATTENZIONE Quando non si sta testando il rilevatore e l apparecchio correttamente Il rilevatore non funzioner fino a quando la batteria emette un suono significa che sono state rilevate delle particelle di non sar posizionata correttamente fumo Assicurarsi della gravit della situazione rilevata L allarme pu essere causato da fumo proveniente dalla cucina Se succede aprire una finestra e fare circolare l aria in manie
14. er a detector s sensing chamber they may cause a nuisance alarm Where bugs are a problem get rid of them before putting up a detector e Near fluorescent lights electrical noise from fluorescent lights may cause nuisance alarms Install smoke detectors at least 5 feet 1 5 meters from such lights WARNING Never remove batteries to stop a nuisance alarm Open a window or fan the air around the detector to get rid of the smoke The alarm will turn itself off when the smoke is gone If nuisance alarms persist attempt to clean the detector as described in this User s Manual WARNING Do not stand close to the detector when the alarm is sounding The alarm is loud in order to wake you in an emergency Too much exposure to the horn at close range may be harmful to your hearing ELCART DISTRIBUTION SPA via Michelangelo Buonarroti 46 20093 Cologno Monzese Milano ITALY Tel 39 02 25117310 Fax 39 02 25117610 sito internet www elcart com e mail info elcart it La divulgazione dei dati contenuti in questa scheda da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product La divulgacion de los datos contenidos en esta ficha son un servicio uni
15. feet 12 meters long e Install a smoke detector inside every room where one sleeps with the door partly or completely closed since smoke could be blocked by the closed door and a hallway alarm may not wake up the sleeper if the door is closed DINING ROOM KITCHEN BEDROOM BEDROOM O LIVING ROOM O BEDROOM O SMOKE DETECTORS FOR MINIMUM SECURITY SMOKE DETECTORS FOR MORE SECURITY Figure 1 locations for placing smoke detectors for single residence with only one sleeping area KITCHEN BEDROOM BEDROOM O O LIVING ROOM FAMILY ROOM O SMOKE DETECTORS FOR MINIMUM SECURITY O SMOKE DETECTORS FOR MORE SECURITY BEDROOM Figure 2 locations for placing smoke detectors for single floor residence with more than one sleeping area SMOKE DETECTORS FOR MINIMUM SECURITY Figure 3 locations for placing smoke detectors for a multi floor residence e Install basement detectors at the bottom of the basement stairwell e Install second floor detectors at the top of the first to second floor stairwell e Be sure no door or other obstruction blocks the path of smoke to the detector e Install additional detectors in your living room dining room family room attic utility and storage rooms e Install smoke detectors as close to the center of the ceiling as possible If this is not practical put the detector on the ceiling no closer than 4 inches 10 cm from any wall or corner a
16. ficare il corretto funzionamento del rilevatore ELCARI Manuale di istruzioni Scheda tecnica PAGINA 4 DI 8 Specifiche tecniche Alimentazione 1 Batteria 6F22 9VCC Consumo allarme disattivo S5UA Consumo allarme attivo lt 15mA Frequenza segnale LED in modalit normale Once every 32 sec Frequenza segnale LED in modalit allarme Once every 0 62 sec Segnalazione Batteria Scarica Un beep sonoro una volta ogni minuto Condizioni Operative Temperatura 10 C 55 C Umidit relativa lt 95 senza condensa Area di copertura 20m Livello di suono allarme 85dB 3mt Frequenza di trasmissione 315MHz 433 92MHz or 868MHz Distanza di trasmissione lt 80mt in spazio aperto SMK 500 Materiale Plastica ABS Dimensioni LxWxH 102x102x31 mm A Informazione agli utenti ex art 26 D Lgs 49 2014 Il simbolo riportato sull apparecchiatura Allegato IX D Lgs 49 2014 indica che il rifiuto deve essere oggetto di raccolta separata e che stato immesso sul mercato in Italia dopo il 31 12 2010 Pertanto l utente dovr conferire o far conferire il rifiuto ai centri di raccolta differenziata predisposti dalle amministrazioni locali oppure consegnarlo al rivenditore contro acquisto di una nuova apparecchiatura di tipo equivalente L utente ha dunque un ruolo attivo la raccolta differenziata del rifiuto e le successive operazioni di trattamento recupero e smaltimento favoriscono la produzi
17. gible to get free of charge assignation to retail shops with sales areas relating to EEE of at least 400 m IMPORTED AND DISTRIBUTED BY RoHS ELCART DISTRIBUTION SPA compliant Via Michelangelo Buonarroti 46 20093 COLOGNO MONZESE MI C ITALY www elcart com info elcart it Made in China ELCART DISTRIBUTION SPA via Michelangelo Buonarroti 46 20093 Cologno Monzese Milano ITALY Tel 39 02 25117310 Fax 39 02 25117610 sito internet www elcart com e mail info elcart it La divulgazione dei dati contenuti in questa scheda da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto
18. he control panel is in learning state 2 Press the testing button on the smoke detector for 3 seconds two beeps are heard Simultaneously one beep is heard from the control panel The detector has been connected successfully with the control panel Testing Press the testing button on the smoke detector for 3 seconds the control panel will alarm immediately Red LED Indicator The red LED as the ALARM indicator is featured with the detector It can be seen through the test button on the cover of the detector When red LED flashes once 32 seconds it indicates the detector under normal operation When smoke detector senses smoke and simultaneously sounds an audible alarm the red LED will flash very frequently once 0 67 seconds Testing Your Smoke Detector Test the detector weekly by pushing firmly on the test button with your finger until the horn sounds Testing method may take up to 5 seconds to sound the alarm horn These are only ways to be sure that detector is working correctly If the detector fails to test properly have it repaired or replaced immediately WARNING Never use an open flame to test your detector You may set fire to damage the detector as well as your home The built in test switch accurately tests all detector functions as required by Underwriters Laboratories They are the only correct ways to test the unit WARNING When you are not testing the unit and the alarm horn sounds a lo
19. ic finished or unfinished furnace rooms utility room basement integral or attached garage and hallways not included in 2 4 1 1 above However the use of additional detectors remains the option of the householder We recommend complete coverage and use of additional smoke detectors Locations not to Install Your Smoke Detectors Nuisance alarms take place when smoke detectors are installed where they will not work properly To avoid nuisance alarms do not install smoke detectors in the following situations Combustion particles are the by products of something that is burning Thus in or near areas where combustion particles are present you do not install the smoke detectors to avoid nuisance alarms such as kitchens with few windows or poor ventilation garages where there may be vehicle exhaust near furnaces hot water heaters and space heaters Do not install smoke detectors less than 20 feet 6 meters away from places where combustion particles are normally present like kitchens If a 20 foot distance is not possible e g in a mobile home try to install the detector as far away from the combustion particles as possible preferably on the wall To prevent nuisance alarms provide good ventilation in such places IMPORTANT For any reason do not disable the detector to avoid nuisance alarms When air streams passing by kitchens the way how a detector can sense combustion particles in normal air flow paths is graphically
20. ituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto ART 35 08410 00 E LCART PAGINA 3 DI 8 Manuale di istruzioni Scheda tecnica NOTE Quando la batteria stata inserita il rilevatore emetter A un beep sonoro per confermare che la batteria stata inserita Installazione del rilevatore di fumo correttamente Chiudere il coperchio e premere il tasto di test per 5 secondi fino a che non viene emesso un suono Ci significa che l apparecchio funziona correttamente Il rilevatore di fumo stato progettato per essere installato sul soffitto o sul muro se necessario Riferirsi prima ai due paragrafi precedenti per decidere dove e come installarlo Seguire i passi seguenti per installare il rilevatore di fumo ACICPARIANTE 1 Scegliere il luogo di installazione e tracciare una linea orizzontale lunga 15 cm 2 Rimuovere la staffa dall unit ruotandola in senso antiorario 3 Fissare la piastra di base nella posizione di montaggio desiderata e contrassegnare i due fori con una penna 4 Rimuovere la staffa 5 Praticare due fori con una punta da trapano di 5 mm ed inserire due stopper nei fori Tenere il rilevatore di fumo lontano da eventuale polvere causata dal trapano 6 Fissare la piastra inferiore con le viti e tasselli corrispondenti i 7 Allineare il rilevatore alla staffa premerlo contro e ruotarlo in senso Abbinamento del rilevatore orario per bloccarlo Assicurarsi che l inst
21. o allarmi indesiderati Quando gli insetti possono essere un problema disinfestare l area prima di installare i rivelatori e In prossimit di luci fluorescenti Il rumore elettrico delle luci fluorescenti pu causare falsi allarmi Installare i rivelatori di fumo ad almeno 1 5 metri da queste luci ATTENZIONE Non togliere mai la batteria del rilevatore per fare cessare allarmi indesiderati Aprireuna finestra o attivare un ventilatore per fare partire via il fumo Il rilevatore si disattiver da solo Se l allarme persiste pulire il rilevatore come descritto in questo manuale di istruzioni ATTENZIONE Evitare di rimanere troppo a lungo vicino al rilevatore quando in allarme Il rumore potente l eccessiva esposizione potrebbe danneggiare l udito ELCART DISTRIBUTION SPA via Michelangelo Buonarroti 46 20093 Cologno Monzese Milano ITALY Tel 39 02 25117310 Fax 39 02 25117610 sito internet www elcart com e mail info elcart it La divulgazione dei dati contenuti in questa scheda da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no const
22. ommended best and acceptable locations to mount smoke detectors DETECTOR ll 9 FEET HORIZONTAL DISTANCE FROM PEAK Figure 5 recommended locations to mount smoke detectors in rooms with sloped gabled or peaked ceiling CAUTION As required by the California State Fire Marshall Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows 1 A smoke detector installed in each separate sleeping area in the vicinity but outside of the bedrooms and 2 Heat or smoke detectors in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms basements and attached garages For your information NFPA Standard 74 Section 2 4 reads as follows 2 4 1 1 Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics The provisions of 2 4 1 1 represent the minimum number of detectors required by this standard It is recommended that the householder considers the use of additional smoke detectors for increased protection for those areas separated by a door from the areas protected by the required smoke detectors under 2 4 1 1 above The recommended additional areas are living room dining room bedroom s kitchen att
23. one di apparecchiature con materiali riciclati e limitano gli effetti negativi sull ambiente e sulla salute eventualmente causati da una gestione impropria del rifiuto Nel caso di RAEE di piccolissime dimensioni lt 25 cm l utente ha diritto al conferimento gratuito senza obbligo di contestuale acquisto ai distributori al dettaglio la cui superficie di vendita specializzata eccede i 400 mq RoHS compliant IMPORTATO E DISTRIBUITO DA ELCART DISTRIBUTION SPA Via Michelangelo Buonarroti 46 20093 COLOGNO MONZESE MI ITALY www elcart com info elcart it Made in China ELCART DISTRIBUTION SPA via Michelangelo Buonarroti 46 20093 Cologno Monzese Milano ITALY Tel 39 02 25117310 Fax 39 02 25117610 sito internet www elcart com e mail info elcart it La divulgazione dei dati contenuti in questa scheda da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto ART 35 08410 00 Smoke Detector User Manual deal for All Areas ART 35 08
24. ra da rimuovere il fumo Il rilevatore di fumo smetter di suonare appena l aria sar pulita NOTA Non disconnettere l alimentazione o estrarre la batteria dal rilevatore La sua abitazione non sar pi protetta dal fuoco ELCART DISTRIBUTION SPA via Michelangelo Buonarroti 46 20093 Cologno Monzese Milano ITALY Tel 39 02 25117310 Fax 39 02 25117610 sito internet www elcart com e mail info elcart it La divulgazione dei dati contenuti in questa scheda da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto ART 35 08410 00 Funzione di tacitazione dell allarme La funzione di tacitazione permette di silenziare la segnalazione acustica a seguito di un allarme per un periodo di tempo di 8 minuti Per attivare questa funzione premere il tasto Test Durante il periodo di tacitazione la spia Led lampegger ogni 8 secondi durante 8 minuti per ricordare che la funzione attivata Passato il tempo di 8 minuti la spia Led smetter di lampeggiare per segnal
25. replacement battery use Gold Peak 1604P 1604S 1604G 1604A Eveready522 216 Duracell Mn1604 Premisafe G6F22 Ultralife U9VL J EVE CR9V WARNING Do not use any other kind of battery This detector may not operate properly with other kind of battery Open the cover and vacuum the dust off the detector s sensing chamber at least once a year This can be done when you open the detector to change the battery Remove battery before cleaning To clean detector use soft brush attachment to your vacuum Carefully remove any dust on detector components especially on the openings of the sensing chamber Replace battery after cleaning Test detector to make sure battery works correctly Check to make sure there is no obstruction inside the test button If there is any dust in the test button insert a toothpick from the back to the front NOTE If nuisance alarms keep coming from the detector you should check whether the detector s location is adequate Refer to section WHERE TO INSTALL SMOKE DETECTORS Move your detector if it is not located properly Clean detector as described above Clean detector cover when it gets dirty First open the cover and remove battery Hand wash cover with cloth dampened with clean water Dry it with lint free cloth Do not get any water on the detector components Replace the battery and close cover Test detector to make sure that battery works correctly ELCARI Manuale di istruzioni Scheda tecnic
26. s shown in Figure 4 e If ceiling mounting is not possible and wall mounting is permitted by your local and state codes put wall mounted detectors between 4 and 6 inches 10 15 cm from the ceiling also see Figure 4 If some of your rooms have sloped peaked or gabled ceilings try to mount detectors 3 feet 0 9 meter measured horizontally from the highest point of the ceiling as shown in Figure 5 ELCART DISTRIBUTION SPA via Michelangelo Buonarroti 46 20093 Cologno Monzese Milano ITALY Tel 39 02 25117310 Fax 39 02 25117610 sito internet www elcart com e mail info elcart it La divulgazione dei dati contenuti in questa scheda da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto ART 35 08410 00 ELCART Manuale di istruzioni Scheda tecnica PAGINA 6 DI 8 4in CEILING 10cm il Lg Le 4in 10cm Minimum CENTER OF NEVER i 6in 15cm CEILING HERE 34 7 Maximum Vv 4 BEST LOCATION lt 21 gt ACCEPTABLE LOCATION Figure 4 rec
27. sarda ripostiglio cantina garage integrato o collegato e corridoi non inclusi nel 2 4 1 1 sopra Tuttavia l uso di rilevatori aggiuntivi non obbligatorio ed una decisione del capo famiglia Raccomandiamo una copertura completa e l uso di rivelatori di fumo e calore supplementari Dove non installare i rilevatori di fumo falsi allarmi possono avvenire se i rivelatori vengono installati dove non funzionerebbero correttamente Per evitare i falsi allarmi non installare i rivelatori di fumo e di calore nelle seguenti situazioni e In prossimit di zone dove sono presenti particelle di combustione tali come cucine con poche finestre o poca ventilazione garages dove si possono trovare fumi di scarico provenienti da veicoli riscaldamento ad acqua calda riscaldatori e Non installare i rilevatori di fumo a meno di 6 metri da luoghi dove le particelle di combustione sono presenti come cucine Se una possibile distanza non ottenibile provare ad installare il rivelatore il pi lontano possibile dalle particelle di combustione preferibilmente sul muro Provvedere ad una adeguata ventilazione ELCARI Manuale di istruzioni Scheda tecnica PAGINA 2 DI 8 IMPORTANTE Per qualsiasi motivo non disabilitare l unit per evitare allarmi indesiderati In condotte di areazione della cucina Il modo in cui un rilevatore di fumo rivela le particelle di combustione in normali percorsi di corrente d aria mostr
28. temi di allarme Questo rilevatore da solo non risulta adatto alla completa sostituzione di un sistema antincendio in locazioni dove lavorano molte persone come alberghi o motels dormitori ospedali case di cura e cosi via anche se sono edifici singoli Si prega di riferirsi ai codici NFPA 101 NFPA71 72A 72B 72C 72D e 72E per le esigenze sui sensori di fumo per la protezione antiincendio in stabilimenti non definiti come abitazioni Ubicazioni per l installazione del rilevatore di fumo rilevatori di fumo devono essere installati in accordo con lo standard NFPA 72 Associazione nazionale protezione antiincendio Per una completa copertura in ambienti residenziali i rilevatori di fumo dovrebbero essere installati in tutte le stanze corridoi magazzini e attici La copertura minima costituita da un rivelatore per ogni piano e uno in ogni area da notte ELCARI Manuale di istruzioni Scheda tecnica PAGINA 1 DI 8 Alcune informazioni utili e Installare un rilevatore di fumo nel corridoio all esterno di ogni camera da letto separata come indicato nella Figura 1 In abitazioni con due camere da letto saranno necessari due rilevatori come indicato nella Figura 2 e Nel caso di abitazioni a pi piani installare un rilevatore di fumo per piano come mostrato nella Figura 3 e Installare un minimo di due rilevatori in ogni abitazione e Installare un rilevatore di fumo all interno di ogni camera da letto e Install
29. tte il segnale di batteria scarica ogni minuto NOTA Utilizzare solo batterie di tipo Gold Peak 1604P 1604S 1604G 1604A Eveready 522 216 Duracell Mn1604 Premisafe G6F22 Ultralife U9VL J EVE CR9V ATTENZIONE Non utilizzare altri tipi di batterie Il rilevatore potrebbe non funzionare correttamente Aprire il coperchio ed aspirare la polvere particelle presenti nella camera di rilevazione almeno una volta al anno Si pu effettuare la pulizia ogni volta che si sostituisce la batteria Prima di pulire il rilevatore estrarre la batteria Utilizzare un aspirapolvere a spazzola soprattutto in corrispondenza della aperture della camera di rilevazione Terminata la pulizia rimettere la batteria e testare il rilevatore per verificarne il corretto funzionamento Mai utilizzare agenti liquidi per pulire Verificare che non rimanga polvere sul tasto Test Rimuovere la polvere con uno stuzzicadenti con cautela NOTA Se il rilevatore rileva frequentemente falsi allarmi si deve controllare se la posizione di installazione del rilevatore appropriata Riferirsi alla sezione UBICAZIONI PER L INSTALLAZIONE DEL RILEVATORE DI FUMO Spostare il rilevatore se non stato posizionato correttamente Pulire il rilevatore come indicato in precedenza Non immergere il prodotto in acqua Non utilizzare detergenti abrasivi o a base di sostanze chimiche Sostituire la batteria e rimettere il coperchio adeguatamente Effettuare un test per veri
30. ttery 2 Match terminals on the end s of the battery with opposite terminal connections on the detector Be sure to insert the zinc manganese dry battery in the position shown on the detector 3 When terminals are properly matched push battery firmly in until it snaps and cannot be shaken loose BATTERY CAUTION This smoke detector comes with cover latches that will prevent the smoke detector cover from closing if battery is not installed This tells you that the smoke detector will not work until a new battery is properly installed The battery is purposely positioned WRONGLY in the factory to keep it fresh until installation It must be re positioned correctly to provide DC power ELCART Manuale di istruzioni Scheda tecnica PAGINA 7 DI 8 NOTE When the detector battery first makes contact with the detector the alarm horn may sound for one second This is normal and indicates that the battery is positioned properly Close cover then press the test button holding it down for about 5 seconds until the horn sounds The horn should sound a loud pulsating alarm This means the unit is working properly LOUDSPEAKER NOT PAN 7 IYANA SN A D TESTING BUTTON RED LED Connect with Alarm Control Panel SMK 500 can not only work as a single station but also can work with alarm control panel to form an alarm system when wireless module is added to the smoke detector 1 Make sure t
31. ud continuous sound this means the detector has sensed smoke or combustion particles in the air Be sure that the alarm horn is a warning of a possible serious situation which requires your immediate attention The alarm could be caused by a nuisance situation Cooking smoke or a dusty furnace sometimes called friendly fires can cause the alarm to sound If this happens open a window or fan the air to remove the smoke or dust The alarm will turn off as soon as the air is completely clear NOTE Do not disconnect the battery from the detector This will remove your protection from fires ELCART DISTRIBUTION SPA via Michelangelo Buonarroti 46 20093 Cologno Monzese Milano ITALY Tel 39 02 25117310 Fax 39 02 25117610 sito internet www elcart com e mail info elcart it La divulgazione dei dati contenuti in questa scheda da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto ART 35 08410 00 Using The Silence Feature The silence feature can temporarily q
32. uiet an unwanted alarm for up to 8 minutes To use the feature press the TEST button When remain in silence the LED will flash once every 8 seconds for up to 8 minutes to remind you the alarm has been stopped The flashing LED will stop when the unit returns to normal operation WARNING The silence feature does not disable the unit It is temporarily less sensitive to smoke For your safety if smoke around the unit is dense enough to suggest a potentially dangerous situation it will stay in alarm or may re alarm quickly If you do not know the source of the smoke do not assume it is an unwanted alarm Not responding to an alarm can result in property loss injury or death NOTE Do not disconnect the battery from the detector This will remove your protection from fires If a beep or chirp virtually simultaneously with an LED flash once a minute this means the detector s battery is weak Replace new battery immediately If a beep or chirp occurring halfway an LED flash once a minute this signal means that the detector is faulting it is must repaired or replaced immediately Taking Care of Your Smoke Detector To keep your detector in good working condition you must test the detector weekly as referring to section TESTING YOUR SMOKE DETECTOR Replace the detector battery when the low battery beep signal sounds once a minute The low battery beep should last at least 30 days NOTE For