Home

TIMER STANDARD ST STANDARD - HY

image

Contents

1. PULSE CONTROLLER SP TECHNICAL DATA Power voltage 230 Vac 10 Network frequency 50 60 Hz 3 Power absorbed 4 6 VA Operative temperature 0 C 50 C Container dimensions 165 x 127 x 70 mm Total weight _ 1 Kg CERTIFICATIONS Electromagnetic Compatibility 89 336 CEE 93 68 CEE Low Voltage 73 23 CEE 93 68 CEE Directive 2002 95 EC RoHS Directive macchine 98 37 CE All materials are according to al DM 443 90 of 21 12 1990 MODALITY OF REGENRERATION Manual Start by Remote Starter external pulse AVAILABLE MODELS Filtration PS0215 SP0 08 05 PS0225 SP2 08 05 PS0235 SP3 08 05 cicles time not programmabile std time of regeneration 30 minutes Softener PS0220 SP0 05 PS0230 SP2 05 PS0240 SP3 05 time cicles not programmable standard time of regeneration 60 minutes POSSIBLE COMBININGS Filtration SPO 08 05 gt PS0035 V132F PS0115 V240P F PS0140 V230F SP2 08 05 gt PS0025 V132E with filter injector PS0105 V240F PS0135 V230E with filter injector PS0161 V250F PS0180 V260F PS0200 V360F SP3 08 05 gt PS0025 V132E with filter injector PS0105 V240F PS0135 V230E with filter injector PS0161 V250F PS0180 V260F PS0200 V360F Softener SP0 05 gt PS0010 V132A PS0110 V240P A PS0125 V230A SP2 05 gt PS0025 V132E PS0085 V240A PS0135 V230E PS0150 V250A PS0155 V250A NB PS0165 V260A PS0185 V36
2. TIMER STANDARD ST DATI TECNICI Tensione di alimentazione 230 Vac 10 Frequenza di rete 50 60 Hz 3 Potenza assorbita 4 6 VA Temperatura operativa 0 C 50 C Dimensioni del contenitore 165 x 127 x 70 mm Peso complessivo 1 Kg CERTIFICATI Compatibilit Elettromagnetica 89 336 CEE 93 68 CEE Bassa Tensione 73 23 CEE 93 68 CEE Direttiva 2002 95 EC RoHS Direttiva macchine 98 37 CE Conformit dei materiali al DM 443 90 del 21 12 1990 RIGENERAZIONE A tempo Alle 3 00 del mattino del giorno selezionato MODELLI DISPONIBILI Filtrazione PS0280 STO 08 05 PS0290 ST2 08 05 PS0300 ST3 08 05 tempi non programmabili durata standard rigenerazione 30 minuti Addolcimento PS0285 ST0 05 PS0295 ST2 05 PS0305 ST3 05 tempi non programmabili durata standard rigenerazione 60 minuti ABBINAMENTI POSSIBILI Filtrazione ST0 08 05 gt PS0035 V132F PS0115 V240P F PS0140 V230F ST2 08 05 gt PS0025 V132E con eiettore per filtro PS0105 V240F PS0135 V230E con eiettore per filtro PS0161 V250F PSO180 V260F PS0200 V360F ST3 08 05 gt PS0025 V132E con eiettore per filtro PS0105 V240F PS0135 V230E con eiettore per filtro PS0161 V250F PSO180 V260F PS0200 V360F Addolcimento ST0 05 gt PS0010 V132A PS0110 V240P A PS0125 V230A ST2 05 gt PS0025 V132E PS0085 V240A PS0135 V230E PS0150 V250A PS0155 V250A NB PS01
3. 0A SP3 05 gt PS0025 V132E PS0085 V240A PS0135 V230E PS0150 V250A PS0155 V250A NB PS0165 V260A PS0185 V360A PROGRAMMAZIONE Il timer pulsi SPO progettato per eseguire la rigenerazione tramite la pressione di un tasto rigenerazione manuale oppure tramite la ricezione di un impulso esterno starter remoto INIZIO RIGENERAZIONE L inizio del ciclo di rigenerazione pu essere attivato o manualmente premendo il pulsante start posto sul pannello frontale o automaticamente tramite un impulso esterno es manometro differenziale totalizzatore rel etc Durante il ciclo di rigenerazione una luce rossa si accender per segriolame il suo inizio rimanendo accesa per tutta la sua urata Motori e personalizzazioni Il timer pulsi SPO disponibile in due versioni da addolcimento e da filtrazione Entrambe le versioni possono essere realizzate sia per il montaggio diretto sulla valvola che per il comando esterno tramite piloti Le combinazioni risultanti sono cos identificate SPO0 05 Controller da addolcimento per montaggio diretto sulla valvola SP2 05 Controller da addolcimento con comando esterno tramite 2 piloti SP3 05 Controller da addolcimento con comando esterno tramite 3 piloti SP0 08 05 Controller da filtrazione per montaggio diretto sulla valvola SP2 08 05 Controller da filtrazione con comando esterno tramite 2 piloti SP3 08 05 Controller da filtrazione con co
4. 110 V240P A PS0125 V230A ST2 05 gt PS0025 V132E PS0085 V240A PS0135 V230E PS0150 V250A PS0155 V250A NB PS0165 V260A PS0185 V360A ST3 05 gt PS0025 V132E PS0085 V240A PS0135 V230E PS0150 V250A PS0155 V250A NB PS0165 V260A PS0185 V360A PROGRAMMAZIONE Il timer standard STO impostato in fabbrica per eseguire la rigenerazione alle ore 3 del mattino di ogni giorno selezionato Impostazione giorno e ora corretti IMPORTANTE La seguente procedura deve essere eseguita attentamente per evitare danni 1 Rimuovere con cura il coperchio trasparente frontale Fare attenzione a non rompere le alette di fissaggio al centro della parte inferiore del coperchio 2 Girare il disco dell ora il disco di destra guardando il timer frontalmente in senso orario e posizionarlo alle 3 del mattino Questo sblocca il movimento del disco dei giorni 3 Girare il disco dei giorni il disco di sinistra guardando il timer frontalmente in senso antiorario fino a che la freccia di riferimento sul pannello non si trova al centro fra due giorni qualsiasi Spostare tutte le leve dei giorni verso l esterno del disco Questo previene qualunque possibilit di danno alla leva del micro switch 4 Girare il disco dei giorni in senso antiorario per allineare il giorno corretto con la freccia di riferimento Il Luned normalmente il giorno 1 5 Girare il disco dell ora in senso orario per allineare l orario corretto con la fr
5. 65 V260A PS0185 V360A ST3 05 gt PS0025 V132E PS0085 V240A PS0135 V230E PS0150 V250A PS0155 V250A NB PS0165 V260A PS0185 V360A STANDARD CONTROLLER ST TECHNICAL DATA Power voltage 230 Vac 10 Network frequency 50 60 Hz 3 Power absorbed 4 6 VA Operative temperature 0 C 50 C Container dimensions 165 x 127 x 70 mm Total weight _ 1 Kg CERTIFICATIONS Electromagnetic Compatibility 89 336 CEE 93 68 CEE Low Voltage 73 23 CEE 93 68 CEE Directive 2002 95 EC RoHS Directive macchine 98 37 CE All materials are according to al DM 443 90 of 21 12 1990 MODALITY OF REGENRERATION Time at 3 a m of every programmed day AVAILABLE MODELS Filtration PS0280 STO 08 05 PS0290 ST2 08 05 PS0300 ST3 08 05 cicles time not programmabile std time of regeneration 30 minutes Softener PS0285 ST0 05 PS0295 ST2 05 PS0305 ST3 05 time cicles not programmable standard time of regeneration 60 minutes POSSIBLE COMBININGS Filtration STO 08 05 gt PS0035 V132F PS0115 V240P F PS0140 V230F ST2 08 05 gt PS0025 V132E with filter injector PS0105 V240F PS0135 V230E with filter injector PS0161 V250F PS0180 V 260F PS0200 V360F ST3 08 05 gt PS0025 V132E with filter injector PS0105 V240F PS0135 V230E with filter injector PS0161 V250F PS0180 V 260F PS0200 V360F Softener T0 05 gt PS0010 V132A PS0
6. assorbita 4 6 VA Temperatura operativa 0 C 50 C Dimensioni del contenitore 165 x 127 x 70 mm Peso complessivo 1 Kg CERTIFICATI Compatibilit Elettromagnetica 89 336 CEE 93 68 CEE Bassa Tensione 73 23 CEE 93 68 CEE Direttiva 2002 95 EC RoHS Direttiva macchine 98 37 CE Conformit dei materiali al DM 443 90 del 21 12 1990 RIGENERAZIONE Manuale tramite starter remoto impulso esterno MODELLI DISPONIBILI Filtrazione PS0215 SPO0 08 05 PS0225 SP2 08 05 PS0235 SP3 08 05 tempi non programmabili durata standard rigenerazione 30 minuti Addolcimento PS0220 SP0 05 PS0230 SP2 05 PS0240 SP3 05 tempi non programmabili durata standard rigenerazione 60 minuti ABBINAMENTI POSSIBILI Filtrazione SPO 08 05 gt PS0035 V132F PS0115 V240P F PS0140 V230F SP2 08 05 gt PS0025 V132E con eiettore per filtro PS0105 V240F PS0135 V230E con eiettore per filtro PS0161 V250F PSO180 V260F PS0200 V360F SP3 08 05 gt PS0025 V132E con eiettore per filtro PS0105 V240F PS0135 V230E con eiettore per filtro PS0161 V250F PSO180 V260F PS0200 V360F Addolcimento SP0 05 gt PS0010 V132A PS0110 V240P A PS0125 V230A SP2 05 gt PS0025 V132E PS0085 V240A PS0135 V230E PS0150 V250A PS0155 V250A NB PS0165 V260A PS0185 V360A SP3 05 gt PS0025 V132E PS0085 V240A PS0135 V230E PS0150 V250A PS0155 V250A NB PS0165 V260A PS0185 V360A
7. c 30 min 19 15min 24 Vac 115Vac 60 min 19 30 min 24 Vac 115Vac 120 min Sono disponibili ulteriori personalizzazioni si consiglia di contattare l Ufficio Tecnico Hytek per maggiori informazioni PROGRAMMING The STO standard timer is set in the factory to carry out the regeneration at 3 a m of every programmed day Setting of correct day and time IMPORTANT The following procedure must be carried out with care in order to avoid damage Carefully remove the transparent front cover Take care not to break the fixing flaps in the centre of the lower part of the cover 2 Turn the time disc the disc on the right clockwise e position it at 3 a m This unlocks the movement of the day disc 3 Turn the day disc the disc on the left frontally looking at the controller anti clockwise until the indicator arrow on the panel is half way between any two days Turn all the day levers towards the outside of the disc Li prevents any possibility of damage to the micro switch ever 4 Turn the day disc anti clockwise to align the correct day with the indicator arrow Monday is normally day 1 5 Turn the time disc clockwise to align the correct timing with the indicator arrow The timing is normally expressed in 24 hours 6 Move towards the centre of the disc the levers for the days on which the regeneration must be carried out 7 Carefully replace the front cover taking care that the fixing levers are correct
8. eccia di riferimento L orario espresso in 24 ore 6 Muovere verso il centro del disco le leve dei giorni in cui deve essere eseguita la rigenerazione 7 Rimontare accuratamente il coperchio frontale assicurandosi che le leve di fissaggio siano correttamente posizionate nei rispettivi fori Motori e personalizzazioni Il controller standard STO disponibile in due versioni da addolcimento e da filtrazione Entrambe le versioni possono essere realizzate sia per il montaggio diretto sulla valvola che per il comando esterno tramite piloti Le combinazioni risultanti sono cos identificate ST0 05 Controller da addolcimento per montaggio diretto sulla valvola ST2 05 Controller da addolcimento con comando esterno tramite 2 piloti ST3 05 Controller da addolcimento con comando esterno tramite 3 piloti STO 08 05 Controller da filtrazione per montaggio diretto sulla valvola ST2 08 05 Controller da filtrazione con comando esterno tramite 2 piloti ST3 08 05 Controller da filtrazione con comando esterno tramite 3 piloti Il motore standard usato per il controller da addolcimento il motore 1 giro 15 minuti 60 minuti totali per rigenerazione da 12Vac mentre per la filtrazione usato il motore 1 giro 7 5 minuti 30 minuti totali per rigenerazione da 12 Vac Sono disponibili i seguenti modelli di motore per le personalizzazioni Velocit Alimlim Durata rigen 1g9 7 5 min 24Vac 115 Va
9. ions are as follows SP0 05 Softening Controller to be mounted directly onto the valve SP2 05 Softening Controller with external control using 2 pilots SP3 05 Softening Controller for external control for example idropneumatic valve using 3 pilots SPO 08 05 Filtration Controller to be mounted directly onto the valve SP2 08 05 Filtration Controller with external control using 2 pilots SP3 08 05 Filtration Controller with external control using 3 pilots The standard motor used for the softening controller is the 1 turn 15 minute 60 minutes for rigeneration at 12Vac motor while for filtration the 1 turn 7 5 minute 30 minutes for rigeneration at 12 Vac motor is used The following motor models are available for customisation Speed Tension Duration of regen 1g 7 5 min 24 Vac 115 Vac 30 min 1g 15min 24 Vac 115 Vac 60 min 1g 30 min 24 Vac 115 Vac 120 min Other custom models are available please contact the Hytek Technical Department
10. ly positioned in their holes Motors and customising Drive motors and personalizations The standard STO controller is available in two versions softening and filtration Both versions can be produced both to be mounted directly onto the valve and for external control using pilots The resulting combinations are as follows ST0 05 Softening Controller to be mounted directly onto the valve ST2 05 Softening Controller with external control using 2 pilots ST3 05 Softening Controller for external control for example idropneumatic valve using 3 pilots STO 08 05 Filtration Controller to be mounted directly onto the valve ST2 08 05 Filtration Controller with external control using 2 pilots ST3 08 05 Filtration Controller with external control using 3 pilots The standard motor used for the softening controller is the 1 turn 15 minute 60 minutes for rigeneration at 12Vac motor while for filtration the 1 turn 7 5 minute 30 minutes for rigeneration at 12 Vac motor is used The following motor models are available for customisation Speed Tension Duration of regen 1g9 7 5 min 24 Vac 115 Vac 30 min 1g 15min 24 Vac 115 Vac 60 min 19 30 min 24 Vac 115 Vac 120 min Other custom models are available please contact the Hytek Technical Department TIMER PULSI SP DATI TECNICI Tensione di alimentazione 230 Vac 10 Frequenza di rete 50 60 Hz 3 Potenza
11. mando esterno tramite 3 piloti Il motore standard usato per il controller da addolcimento il motore 1 giro 15 minuti 60 minuti totali per rigenerazione da 12Vac mentre per la filtrazione usato il motore 1 giro 7 5 minuti 30 minuti totali per rigenerazione da 12 Vac Sono disponibili i seguenti modelli di motore per le personalizzazioni Velocit Alimlim Durata rigen 1g 7 5 min 24Vac 115 Vac 30 min 1g 15min 24 Vac 115Vac 60 min 1g 30 min 24 Vac 115Vac 120 min Sono disponibili ulteriori personalizzazioni si consiglia di contattare l Ufficio Tecnico Hytek per maggiori informazioni PROGRAMMING A new version called STANDARD PULSI is available amongst SIATA controller series allowing the regeneration cycle to start by an external operation manual and automatic START REGENERATION The start of the regeneration cycle can be activated either manually by pressing the start command on the front plate or automatically by receiving an external impulse for example differential manometer totalizzer rel etc During the regeneration cycle a red LED over the start command will light and it will remain turned on for the whole regeneration Drive motors and personalizations The pulsi SPO controller is available in two versions softening and filtration Both versions can be produced both to be mounted directly onto the valve and for external control using pilots The resulting combinat