Home
Istruzioni d`uso
Contents
1. cL IR adjust Ea ICR wire Black ground llia Red 5V Orange OV To Test Monitor 0 Caution Trigger out is active to act ICR from color to black amp white If D N Cameras with trigger in please clarify camera trigger voltage please refer to the wiring diagram as below A If IR trigger signal is on the high position 5Vdc connect the Red and Black wire to D N trigger line of camera B If IR trigger signal is on the Low position 0Vdc connect the Orange and Black wire to D N trigger line of camera Note Connection to 391 774 box camera Orange wire to NA port Black wire to G port SAFETY PRECAUTIONS Please do not directly touch the sensor element If necessary use a soft cloth moistened with alcohol to wipe off any dust Please be extra careful not to shake the camera Please avoid places where there is direct sunlight When using this camera in places where the lighting differs greatly please use an auto iris lens Please avoid places where temperatures exceed 50 C or more high humidity or where direct rain drops hit frequent vibrations or shocks occur During the night if a minimum brightness of 0 2 Lux can not be achieved install appropriate light fixtures When the camera is not used keep the lens or the lens cap attached to protect the sensor RJ45 in Pin Define amp Connection Caution HOUSING RJ 45 Input Data amp Power
2. Pin Symbol Description 1 RX Vin Data Receive Feeding power 2 RX Vin Data Receive Feeding power 3 TX Vin Data Transmit Feeding power 4 Vin Feeding power 5 Vin Feeding power 6 TX Vin Data Transmit Feeding power 7 Vin Feeding power 8 Vin Feeding power FTP Category 6 cable is recommended to field construction Input CAT 6 wire must be with standard RJ45 male connector Aworkable length is not exceed 90 Meter CAT 6 cable from injector no guaranty if CAT 6 cable beyond 90 Meter POE INJECTOR 138mm 104mm POWER amp DATA OUT DATA IN ed ACTIVE POWER LI cli AC IN 100 240V Specifications Input Power Requirements AC Input Voltage 100 240Vac AC Frequency 50 60 HZ AC Input Current 2A at 100Vac 1A at 240Vac Power over LAN output Specification Pin Assignments and Polarity 4 5 7 8 Output Voltage Aggregate Power 50W 48Vdc 2V Output Current 0 1A Tolerance 5 Combination Of Line Load Regulation And Initial Set Mechanical Requirement Dimensions H 1 5 in x W 4 09 in x D 5 43
3. atamente formato e autorizzato da Bticino Qualsivoglia apertura o riparazione non autorizzata comporta l esclusione di eventuali responsabilit diritti alla sostituzione e garanzie Utilizzare esclusivamente accessori a marchio Bticino Cavo di messa a terra 7IR IN PoE Plus IEEE 802 3at OUT PoE IEEE 802 3af Riscaldatore DC 12Ve riparo riscaldatore Unita di potenza PoE Aeratore Piattaforma di montaggio della telecamera Morsettiera La scheda di controllo principale si trova sotto la piattaforma di montaggio della telecamera si veda di seguito per ulteriori dettagli COLLEGAMENTO USCITA TRIGGER PANNELLO DI CONTROLLO regolazione IR Cavo ICR nero terra rosso 5V arancione OV Per test monitor Attenzione Uscita trigger attiva per azionare l ICR da colori a bianco e nero In caso di telecamere D N con ingresso trigger specificare la tensione del trigger fare riferimento allo schema di collegamento seguente A se il segnale di attivazione IR nella posizione alta 5Vdc collegare cavo rosso e nero a linea trigger D N della telecamera B se il segnale di attivazione IR nella posizione bassa 0Vdc collegare cavo arancione e nero a linea trigger D N della telecamera Nota collegamento alla scatola 391 774 della telecamera Filo arancione a porta NA Fi
4. blcino i L alloggiamento di questa telecamera realizzato in lega di alluminio pressofuso con un rivestimento a polvere ed dotato di una staffa di montaggio regolabile gestita interamente da cavo Sorgente di alimentazione conforme allo standard IEEE 802 3at Plus Cavo PoE da 30W in dotazione Questo prodotto certificato CE dotato di livello di protezione ambientale IP 65 ed conforme alle norme RoHS SCHEMA DEI COLLEGAMENTI 230 VAC cavo CAT6 Iniettore PoE INTERRUTTORE cavo CAT6 ALLOGGIAMENTO Dimensioni A Spazio interno per montaggio telecamera Larghezza 100 x Altezza 90 x Lunghezza 275 mm Dimensioni della base della staffa Regolazione di posizione e direzione a 160mm 425mm a mn 165mm Istruzioni di sicurezza ID CW Questo prodotto deve essere installato in conformit con le regole d installazione e di preferenza da un elettricista qualificato L eventuale installazione e utilizzo improprio dello stesso possono comportare rischi di shock elettrico o incendio Prima di procedere all installazione leggere attentamente le istruzioni associate e individuare un luogo di montaggio idoneo in funzione del prodotto Non aprire smontare alterare o modificare l apparecchio eccetto speciale menzione indicata nel manuale Tutti i prodotti Bticino devono essere esclusivamente aperti e riparati da personale adegu
5. er la realizzazione del cablaggio il filo di ingresso categoria 6 deve disporre di connettore maschio standard RJ45 una lunghezza funzionale un cavo CAT 6 dall iniettore che non supera i 90 metri nessuna garanzia in caso di cavi CAT 6 oltre i 90 metri INIETTORE POE 104mm ACTIVE POWER amp DATA OUT DATA IN POWER A mr e Od Hd fe ce ce ee jee ce e e e J e ee ee ee jee ee e e J e e ee ce ee jee ee e e e e e ee ee ee jee ee e e e e e eo ce ee ee ce e e e e e ce ce ee jee ee e a A e e e e ee J L j lijee ee ee ce e e e e e ce ce ee je e ee 138mm ein im Fle e e e ee U Uj jee ee lee ee e ie ee e e e e ce ce ee jee ee e e e J e ee ce ee jee ee e e e e e ee ce ee jee ee e e e e e ce ce ee jee ee e e e e e ce ce ee ee ee ike OF FT Yy ab e AC IN 100 240V Specifiche Requisiti di potenza in ingresso Tensione AC in ingresso 100 240Vac Frequenza AC 50 60 HZ Corrente AC in ingresso 2A a 100Vac 1A a 240Vac Specifica di uscita Power over LAN Attribuzione pin e polarita 4 5 7 8 Tensione in uscita Potenza complessiva 50W 48Vdc 2V Corrente in uscita 0 1A Tolleranza 5 combinazione di l
6. h RoHS regulations CONNECTION DIAGRAM 230 VAC CAT6 cable PoE injector CAT6 SWITCH cable HOUSING Dimensions A Inner space for camera mount W100 x H90 x L275 mm Dimensions of bracket base Adjust position and direction 425mm Safety instructions GBIE This product should be installed in line with installation rules preferably by a qualified electrician Incorrect installation and use can lead to risk of electric shock or fire Before carrying out the installation read the instructions and take account of the product s specific mounting location Do not open up dismantle alter or modify the device except where specifically required to do so by the instructions All Bticino products must be opened and repaired exclusively by personnel trained and approved by Bticino Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees Use only Bticino brand accessories Ground wire 7IR IEEE 802 3at PoE Plus IN IEEE 802 3af PoE OUT DC 12V Heater and Heater shield PoE power unit Blower Camera mounting plateform Terminal block Maint control board lie under camera mounting plateform see below for further descrip CO TROL BOARD TRIGGER OUT CONNECTION
7. in H 3 8 cm x W 10 4cm x D 13 8 cm Weight 13 42 Ibs 6 1Kg Indicators AC Power Green System Indicator Power Active Red 0 05 A lt lo lt 1A Over Current Protection Red Flash Connectors Shielded Rj 45 Environmental Conditions Operating Temperature 32 to 104 F 0 to 40 C Operating Humidity Maximum 90 Non condensing Storage Temperature 13 to 185 F 25 to 85 C Storage Humidity Maximum 95 Non condensing Operating Altitude 1000 to 10 000 ft 304 8 to 3048 mm RJ45 out Pin Define amp Connection INJECTOR RJ 45 Output Data amp Power Pin Symbol Description 1 RX Data Receive 2 RX Data Receive 3 TX Data Transmit 4 Vo Feeding power 5 Vo Feeding power 6 TX Data Transmit Fi Vo Feeding power 8 Vo Feeding power
8. inea regolazione carico e impostazione iniziale Requisiti meccanici Indicatore di sistema Dimensioni A 1 5 x L 4 09 x P 5 43 A 3 8 cm x L 10 4 cm x P 13 8 cm Peso 13 42 Ibs 6 1 kg Indicatori Alimentazione AC verde Alimentazione attiva rosso 0 05 A lt lo lt 1 A Protezione sovracorrente rosso lampeggiante Connettori schermati Rj 45 Condizioni ambientali Temperatura di esercizio da 32 a 104 F da 0 a 40 C Umidit operativa 90 massimo senza condensa Temperatura di immagazzinamento da 13 a 185 F da 25 a 85 C Umidit di immagazzinamento 95 massimo senza condensa Altitudine operativa da 1000 a 10 000 piedi da 304 8 a 3048 m Pin uscita RJ45 Definizioni e collegamenti INIETTORE uscita RJ 45 dati e potenza Pin Simbolo Descrizione 1 RX ricezione dati 2 RX ricezione dati 3 TX trasmissione dati 4 Vo potenza di alimentazione 5 Vo potenza di alimentazione 6 TX trasmissione dati 7 Vo potenza di alimentazione 8 Vo potenza di alimentazione This Camera Housing is constructed by die cast aluminum alloy with powder coated finished and equipped with adjustable Fully Cable Managed Mounting Bracket Power source IEEE 802 3at Plus Compliant 30W PoE is provided The Product is CE certified owns IP 65 environmental protection level and conform wit
9. lo nero a porta G PRECAUZIONI DI SICUREZZA Non toccare direttamente l elemento sensore Se necessario usare un panno morbido inumidito con alcol per rimuovere la polvere Fare molta attenzione a non scuotere la telecamera Evitare luoghi con luce solare diretta Quando si impiega questa telecamera in luoghi in cui vi sono variazioni elevate di luminosit usare una lente con iride automatica Evitare i luoghi in cui la temperatura supera i 50 C l umidit elevata o esposti alle precipitazioni alle vibrazioni frequenti o agli urti Durante la notte qualora non sia possibile ottenere una luminosit minima di 0 2 Lux installare un impianto illuminante adeguato Quando la video camera non viene utilizzata mantenere la lente o il relativo coperchio installati per proteggere il sensore Pin ingresso RJ45 Definizioni e collegamenti ALLOGGIAMENTO ingresso RJ 45 dati e potenza Pin Simbolo Descrizione 1 RX Vin ricezione dati potenza di alimentazione 2 RX Vin ricezione dati potenza di alimentazione 3 TX Vin trasmissione dati potenza di alimentazione 4 Vin potenza di alimentazione 5 Vin potenza di alimentazione 6 TX Vin trasmissione dati potenza di alimentazione 7 Vin potenza di alimentazione 8 Vin potenza di alimentazione Attenzione si raccomanda un cavo FTP categoria 6 p
Download Pdf Manuals
Related Search
Related Contents
Mobile Security Report 2014 - AV U q. ffi ffi ffi EI uim-138 user interface module for the vx2200 system to Serial Flash Memory Denon DN-C635 User's Manual Lowrance electronic EP-80R User's Manual KOMA Elektronik BD101 Analog Gate / Delay USER MANUAL Samsung 60 mm Macro Lens Инструкция по использованию BAIER BDN 466 R RHODIUS Copyright © All rights reserved.