Home

12V 10A 12V 15A 12V 20A

image

Contents

1. 115V m CARTE 12V 20A 230V VUE DE DESSUS CARTE 12V 10A amp 15A VUE DE DESSUS Pb Ca Norm 1 Pb Ca J Norm Fusibles SERV batteries Fusibl t ns T Fusibles batteries Fusible secteur ere MOT i SERV AUX a TN sE P KL qN DC DC1 DC2 DC3 DC DC1 DC2 DC3 Acc s batteries Acc s batteries C bles batterie Veillez la qualit des raccordements et au bon serrage des connections L acc s DC1 doit imp rativement tre raccord la batterie principale Les acc s DC2 et DC3 servent aux batteries moteur et auxiliaire 12V 10A 12V 15A 12V 20A Section pr conis e 3mm2 4mm2 6mm2 Longueur max 1 5 m tres 1 5 m tres 1 5 m tres Reya International www reya com reya reya com V2 Page 13 09 07 08 Fusibles En cas de maintenance des fusibles ceux ci doivent tre remplac s par des fusibles aux caract ristiques et performances strictement identiques Risques de dommages irr versibles sur le mat riel 12V 10A 12V 15A 12V 20A Acc s secteur T3A 250V T4A 250V T5A 250V Acc s Batteries F15A 32V F20A 32V F25A 32V Raccordements secteur amp utilisations PE OKI Ventilateur Carte Chargeur PE Entr e D part D part secteur UTILI UTIL2 Reya International www reya com reya reya com V2 Page 14 09 07 08 C bles secteur Pour la distribution secteur
2. Fuses Fuses should be replaced with fuses that have identical characteristics and performance levels REYA cannot be held responsible for any damage caused where fuse types other than those recommended are used 12V 10A 12V 15A 12V 20A Input gauge T3A 250V T4A 250V T5A 250V Battery Input F15A 32V F20A 32V F25A 32V Reya International www reya com reya reya com V2 Page 7 09 07 08 Input amp Output connections Pc Board A V Y Power UTIL1 UTIL2 Input Output Output Cables For distribution output we recommend you use a HO7RNF cable 12V 10A 12V 15A 12V 20A Recommended gauge 3 x 1 5mm 0 028in 3 x 1 5mm 0 023in 3 x 2 5mm 0 023in Max length 5m 16 5 5m 16 5 5m 16 5 Reya International www reya com reya reya com V2 Page 8 09 07 08 Warranty In order to avoid all risk arising from the incorrect use of this device please carefully read the list of possible situations or faults that are not covered by the warranty The warranty period is valid for three years from the date of purchase For all claims please present your proof of purchase In the absence of this proof the warranty period begins as per the series number on the top of the charger e g 02D01234 made in April 2002 e This device is not protected against reverse battery polarity Irreversible damage may result e If the mechanical components of the device are not protected by th
3. Posizione Pb Ca Calcio piombo CC1 boost norm 14 4V 14 4V 14 4V CC1 boost Pb Ca 15 0V CC1 float Norm amp Pb Ca 13 8V 13 8V 13 8V Uscite CC2 CC3 CC1 0 3V CC1 0 3V CC1 0 3V Tolleranza di tensione 2 2 2 Onde residue lt 1 lt 1 lt 1 Massima corrente di carica 10A 5 15A 5 20A 5 Fusibile F15A F20A F25A Protezione cortocircuito Protezione elettronica Protezione temperatura Vigitherm Inversione di polarit Fusibile protezione batteria Guasto generale Fusibile protezione batteria Visualizzazione a LED On Off LED arancione corrente presente Configurazione Flyback 50KHz amp PFC solamente 20A Temperatura d esercizio 0 C 50 C Temperatura magazzino 20 C 70 C Umidit 10 90 senza condensa Protezione elettronica Per tropicalizzazione Ventilazione Naturale Forzata Forzata Reya International WWW reya com reya reya com V2 Page 17 09 07 08 EMC EN50081 1 EN50082 1 EN61000 3 2 Sicurezza EN60335 1 Collegamento batteria 6 35 Faston 6 35 Faston Morsetto a vite Distribuzione uscite 12V 10A 12V 15A 12V 20A Collegamenti CA Con interruttore differenziale Collegamenti PE Caratteristiche protezione Bulloni M6 all interno della custodia 16A 6 5KA 30mA circuit breaker modulo 4 Uscite 2 uscite protette Connessioni uscite Interruttori magneto termici Connessioni PE Bulloni M6 all int
4. 09 07 08 Technical Specifications Battery Charger 12V 10A 12V 15A 12V 20A Input voltage 230V 115V 230V 115V 98V 264V Input frequency 50Hz 60Hz 50Hz 60Hz 45Hz 65Hz Switch 115V 230V Selector switch Selector switch Automatic Cos 0 7 typ 0 7 typ 0 9 typ Output 80 Power consumed 150W 225W 300W Active power 250VA 350VA 350VA Sector consumption 1A 2A 1 5A 3A 3 7A 1 4A Fuse T3A T4A T5A Number of outlets 2 2 3 Charging curve I U Uo 3 stages Boost Battery Voltage Max current Battery Current Charge selector 2 positions 2 positions 2 positions Norm position All types All types All types Pb Ca position Lead calcium Lead calcium Lead calcium DC1 boost norm 14 4V 14 4V 14 4V DC1 boost Pb Ca 15 0V 15 0V 15 0V DC1 float Norm amp Pb Ca 13 8V 13 8V 13 8V DC2 DC3 outlets DC1 0 3V DC1 0 3V DC1 0 3V Voltage allowance 2 2 2 Residual waves lt 1 lt 1 lt 1 Max charge current 10A 5 15A 5 20A 5 Fuse F15A F20A F25A Short circuit fault Electronic protection Temp fault Vigitherm Reverse polarity Battery fuse protection General fault Battery fuse protection Display LED On Off Orange LED Power connected Configuration Flyback 50KHz amp PFC 20A only Operating temperature OC 50 C Storing temperature 20 C 70 C Humidity 10 90 without con
5. rentiel principal e V rifier la pr sence de la tension secteur e V rifier les raccordements secteur Secteur ON allum Chargeur ON teint Chargeur hors tension e V rifier la pr sence de la tension secteur e V rifier les raccordements secteur e V rifier le fusible secteur D faut temp rature interne 12V 15A amp 20A uniquement e V rifier les conditions d installation et climatiques e V rifier le bon fonctionnement du ventilateur interne Secteur ON allum Chargeur ON clignotant Chargeur vide ou raccord des batteries charg es e Chargeur en stand by fonctionnement normal Reya International V2 Page 12 WWW reya com reya reya com 09 07 08 Chargeur mal raccord c t batteries e V rifier les raccordements batteries Fusibles batteries H S e V rifier la bonne polarit des c bles batteries e Remplacer les fusibles batteries Batteries en d charge tr s profonde e D marrer la recharge par un moyen externe e Remplacer la batterie d fectueuse Secteur ON allum Chargeur ON allum Ventilateur interne en fonctionnement 12V 15A amp 20A uniquement e Chargeur en BOOST et batteries en cours de recharge Ventilateur interne arr t e Chargeur en FLOAT et batteries charg es Raccordements carte chargeur S lecteur 115V 230V
6. www reya com reya reya com V2 Page 5 09 07 08 Power On is On Charger On is blinking Charger not connected to the battery or the batteries completely charged e Charger in stand by mode normal Charger incorrectly connected to the battery e Check battery connection Battery fuses blown e Check the battery cables polarity e Replace the battery fuses with identical fuses Very flat batteries e Charge the battery using an external source e Replace the faulty battery Power On is On Charger On is On Internal fan is working 12V 15A amp 20A only e Charger on BOOST and batteries are charging Internal fan stopped Charger on FLOAT and batteries charged Charger PC Board connections Hiwi 23 Swilchover 115 il tavia amp 15a Sern from above Fa Norm Power supply fica L Batiery fuses MOT SERV y Cc 200 Det 002 003 Dil DICI C2 A Battery Access Battery Access Reya International www reya com reya reya com v2 Page 6 09 07 08 Battery Cables Please ensure the correct and proper installation of all electrical connections It is essential that DC1 is connected to the main battery Please connect DC2 and DC3 to the motor battery and the auxiliary battery respectively 12V 10A 12V 15A 12V 20A Recommended gauge 3mm 0 05in 4mm 0 06in 6mm 0 95in Max length 1 5m 3 3lbs 1 5m 3 3lbs 1 5m 3 3lbs
7. INSTALLATION OPERATION Alh Ore DOLPHIN All in One 3 Marine Electric Cabinets 12V 10A 12V ISA 12V 20A English Version Page 2 Version fran aise Page 9 Versione italiana Page 15 Reya International www reya com reya reya com V2 Page 1 09 07 08 Reya International www reya com reya reya com V2 Page 2 09 07 08 English Version Warning Before Operation The manual contains vital and essential information The owner should read and understand this important document before operating the charger Contact REYA if you do not understand a statement Before Installation In order to avoid overcharging or irreversible damage to the materials please follow closely all recommendations cited below Do not install this system near inflammable materials An owner should seek guidance from an authorized DOLPHIN dealer or the factory e Do not install this system near a heat source e It should not be installed in an airtight or badly ventilated area e All ventilation ducts must be unobstructed e Mount in a vertical position to create natural ventilation for the charger Note that the wiring connections are at the bottom of the charger Leave at least three inches clearance above and below the unit for proper ventilation e This system should not be exposed to water or dust e Itis strictly forbidden to tamper with the system casing Connecting the Unit In order to avoid all risk of electric shock or irreversible damage to the unit ple
8. a batteria F15A 32V F20A 32V F25A 32V Reya International www reya com reya reya com V2 Page 20 09 07 08 Collegamenti di entrata e di uscita Ventilatore N V Y Entrata UTIL1 UTIL2 corrente Uscita Cavi di uscita Per la distribuzione delle uscite si raccomanda di usare cavo del tipo HO7RNF 12V 10A 12V 15A 12V 20A Sezione raccomandata 3 x 1 5mm 0 028in 3 x 1 5mm 0 023in2 3 x 2 5mm 0 023in2 Lunghezza massima 5m 16 5 5m 16 5 5m 16 5 Reya International www reya com reya reya com V2 Page 21 09 07 08 Garanzia AI fine di evitare ogni eventuale rischio dovuto all uso improprio di questo dispositivo si prega di leggere attentamente l elenco delle possibili situazioni o guasti non coperti dalla garanzia e Questo apparato non protetto contro l inversione della polarit della batteria Si potrebbero verificare danni irreparabili e Se i componenti meccanici del dispositivo non sono protetti dalla custodia e dalle cadute si potrebbero verificare danni irreparabili al sistema di ventilazione ed ad alcuni componenti elettrici e Le modifiche alla custodia e in particolare se si praticano dei fori potrebbero causare depositi di segatura o trucioli metallici sulla scheda elettronica con conseguente malfunzionamento o guasto del dispositivo e La manomissione o la modifica della scheda elettronica potrebbe provocare funzionamenti imprevisti c
9. ase follow very carefully the following recommendations e This unit is set to be connected to a monophase network 230V 50Hz or 115V 60Hz e Onthe 12V 10A and 12V 15A models the 115V 230V selection is done by an internal switch This manipulation must be done when the device is switched off The position of the switch must follow the sector power supply conditions e Onthe 12V 20A 115V 230V selection is automatic e For security reasons the system s PE terminal must strictly be connected to the installation s Earth green yellow wire in the cable section e To prevent overheating ensure the correct connection of cables NB If reverse polarity of the batteries occurs the battery fuses will automatically blow Start up precautions e In order to prevent all risk of electric shocks at either start up or during the utilization of this system the protection cap must rest in place and be tightly screwed Maintenance precautions In order to prevent risk of electric shocks during maintenance please follow closely all recommendations below before any maintenance begins e Disconnect the cable e The access to DC or BAT must be disconnected in order to avoid transfer of energy e Please wait five minutes before accessing the casing as the high tension condensation will need time to discharge e Fuses must be replaced by fuses that have the same characteristics and performance levels Reya International www reya com reya reya com V2 Page 3
10. dei cavi sono nella parte inferiore del carica batterie Per assicurare l opportuna ventilazione lasciare uno spazio minimo di 7 8 cm sopra e sotto l apparato e Questo apparato non va esposto all acqua e alla polvere e assolutamente proibito manomettere la custodia dell apparato Collegamento dell apparato Per evitare qualsiasi rischio di scossa elettrica o eventuali danni all apparato si invita a seguire scrupolosamente le raccomandazioni che seguono e Questo apparato adatto ad essere collegato o alla rete elettrica monofase da 230 V 50 Hz o a quella a 115 V 60 Hz e Sui modelli 12V 10A e 12V 15A la commutazione 115V 230V viene attuata con un interruttore interno Eseguire questa commutazione solamente con l apparato spento La posizione del commutatore dovr essere conforme alle condizioni di fornitura della rete elettrica e Sul modello 12V 20A 115V 230V la commutazione automatica e Per motivi di sicurezza il terminale PE dell apparato dovr essere tassativamente collegato alla massa dell impianto filo giallo verde del cavo di alimentazione e Per prevenire surriscaldamenti eseguire il collegamento dei cavi in modo corretto NB Nel caso si collegassero le batterie con la polarit invertita si bruceranno gli specifici fusibili di protezione Precauzioni di avviamento e Al fine di evitare ogni rischio di scossa elettrica sia all avviamento sia durante il normale utilizzo di questo apparato il tappo di protezio
11. densation Electronic protection By tropicalization Ventilation Natural Forced Forced Reya International www reya com reya reya com V2 Page 4 09 07 08 EMC EN50081 1 EN50082 1 EN61000 3 2 Security EN60335 1 Battery connections 6 35 Faston 6 35 Faston Terminal screw Output Distribution 12V 10A 12V 15A 12V 20A AC Connections By differential circuit breaker PE Connections M6 bolts on the box Protection characteristics 16A 6 5KA 30mA 4 module circuit breaker Outputs 2 protected outputs Outlet connections Thermo magnetic circuit breakers PE Connections ME bolts on the box Protection characteristics 10A 6 5KA 1 module circuit breaker Box Painted aluminum Mounting Wall mounted 4 x 4mm 0 1576 screws Height x width x depth 280 x 270 x 100 mm 11 03 x 10 64 x 3 94 Weight 3kg 6 621bs Security ISO13297 Operating instructions 44424429 ELLE tw Both LEDs Off All in one is off e Check the main differential circuit breaker e Check power input e Check the input cables Power On is On Charger On is Off Charger is off e Check power input e Check the input cables e Check main fuse Defective internal temperature 12V 15A amp 20A only e Check the installation and climatic conditions e Check the internal fan is operational Reya International
12. e casing and fall irreversible damage of the ventilation system and certain electrical components may result e Modifications made to the casing and in particular if holes are bored may result in the deposit of metallic shavings or filings onto the electronic card and consequently may cause the malfunction of or damage to the device e Interfering with or modifications made to the electronic card may result in unforeseen operations and consequently may cause the malfunction of or damage to the device e Use of a non adapted power supply as a general rule the input voltage will be too high may cause the malfunction of or damage to the device e An accidental electrical surcharge or lightening strike will generally cause the malfunction of or damage to the device e Replacement of battery fuses with fuse types other than those recommended same characteristics may cause the malfunction of or damage to the device e Obvious connection errors will result in the malfunction of or damage to the device e Water gaining access to the interior of the device may cause the malfunction of or damage to the device Reya International www reya com reya reya com V2 Page 9 09 07 08 Version fran aise Pr cautions de s curit Afin de pr venir tout risque de choc lectrique ou d incendie lire attentivement ce manuel avant d installer l appareil Cet appareil contient des composants qui peuvent provoquer des arcs lectriques ou tincelles lors d
13. e doit imp rativement s effectuer hors tension La position du strap doit suivre de mani re rigoureuse les conditions d alimentation secteur e Sur le mod le 12V 20A la s lection 115V 230V est automatique e Pour des raisons de s curit la borne PE de cet appareil doit imp rativement tre raccord e la terre g n rale de l installation fil vert jaune du c ble secteur e Pour pr venir tout chauffement parasite veiller la bonne section des cables ainsi qu aux bons serrages des connections IMPORTANT Une inversion de polarit c t batteries entra ne automatiquement la rupture des fusibles batteries Pr cautions de mise en service Afin de pr venir tout risque de choc lectrique lors de la mise en service ou pendant le fonctionnement le capot de protection doit imp rativement tre en place et correctement viss sur le b ti Pr cautions de maintenance Afin de pr venir tout risque de choc lectrique lors des op rations de maintenance veillez suivre de mani re imp rative les recommandations qui suivent avant d intervenir dans l appareil e L acc s secteur doit imp rativement tre d connect cable ou sectionneur e L acc s DC ou BAT doit lui aussi tre d connect pour viter tout transfert d nergie e Pour permettre aux condensateurs haute tension de se d charger attendre 5 minutes avant d intervenir dans le coffret e Les fusibles doivent tre remplac s par des fusibles aux caract rist
14. erno della custodia Caratteristiche protezione 10A 6 5KA circuit breaker modulo 1 Custodia Alluminio verniciato Montaggio A parete viti da 4 x 4mm 0 1576 alto x largo x profondo 280 x 270 x 100 mm 11 03 x 10 64 x 3 94 Peso 3kg 6 621bs Sicurezza 15013297 Istruzioni d uso does s ELLE 204 LED Corrente on spento LED Carica on spento All in One fuori tensione e Controllare lo stato dell interruttore principale e Controllare la presenza del della tensione del settore e Controllare i collegamenti del settore LED Corrente on acceso LED Carica on spento Carica batterie collegato in modo errato alla batteria e Verificare la presenza della tensione e Verificare i collegamenti e Verificare i fusibili Difetto temperatura interna e Controllare le condizioni di isntallazione e climatiche e Verificare il buon funzionamento della ventola interna Reya International www reya com V2 Page 18 reya reya com 09 07 08 LED Corrente on acceso LED Carico on lampeggiante Caricabatteria a vuoto o collegato a delle batterie cariche e caricabatteria in stand by funzionamento normale Carica batterie collegato alla batteria in modo errato e Verificare i collegamenti alla batteria Fusibile della batteria fuori servizio e Verificare la polarit dei cavi della batteria e Sostituire i f
15. es raccordements par exemple Afin de pr venir tout risque d incendie ou d explosion ne pas installer cet appareil a proximit de mat riels liquides ou gaz inflammables Pr cautions d installation Afin de pr venir tout risque de surchauffe ou de dommage irr versible sur le mat riel veillez suivre de mani re imp rative et rigoureuse les recommandations ci dessous e Cet appareil ne doit pas tre install proximit d une source de chaleur Il ne doit pas tre install dans un compartiment tanche ou mal a r Les ou es de ventilations ne doivent pas tre obstru es Un espace libre d au moins 10cm doit tre pr vu tout autour du coffret pour permettre une bonne convection Cet appareil ne doit pas tre expos aux ruissellements aux projections d eau et aux poussi res de toutes natures Il est recommand de fixer l appareil en position verticale la sortie des c bles orient e vers le bas Il est formellement interdit de modifier m caniquement le coffret par des per ages suppl mentaires par exemple Pr cautions de raccordements Afin de pr venir tout risque de choc lectrique ou de dommage irr versible sur le mat riel veillez suivre de mani re imp rative les recommandations ci dessous e Cet appareil est pr vu pour tre raccord sur des r seaux monophas s 230V 50Hz ou 115V 60Hz e Sur les mod les 12V 10A et 12V 15A la s lection 115V 230V s effectue par commutation du strap interne Cette man uvr
16. iques et performances strictement identiques Reya International www reya com reya reya com V2 Page 10 09 07 08 Chargeur de batteries Sp cifications techniques 12V 10A 12V 15A 12V 20A Tension secteur 230V 115V 230V 115V 98V 264V Fr quence secteur 50Hz 60Hz 50Hz 60Hz 45Hz 65Hz Commutation 115V 230V S lecteur S lecteur Automatique Coso 0 7 typ 0 7 typ 0 9 typ Rendement 80 typ Puissance consomm e 150W 225W 300W Puissance active 250VA 350VA 350VA Consommation secteur 1A 2A 1 5A 3A 3 7A 1 4A Fusible secteur T3A T4A T5A Nombre de sorties 2 sorties 3 sorties 3 sorties Courbe de charge U Uo 3 tats A Boost Float V bat I max I bat gt S lecteur de charge 2 positions 2 positions 2 positions Position Norm Tous types Tous types Tous types Position Pb Ca Plomb Calcium Plomb Calcium Plomb Calcium Boost DC1 Norm 14 4V 14 4V 14 4V Boost DC1 Pb Ca 15 0V 15 0V 15 0V Float DC1 Norm amp Pb Ca 13 8V 13 8V 13 8V Sorties DC2 DC3 DC1 0 3V DC1 0 3V DC1 0 3V Tol rance tensions 2 2 2 Ondulation r siduelle lt 1 lt 1 lt 1 Courant max de charge 10A 5 15A 5 20A 5 Fusibles de sorties F15A F20A F25A D faut court circuit Protection lectronique D faut temp rature Vigitherm Inversion de polarit Protec
17. larit s par exemple ou secteur par des fusibles aux caract ristiques diff rentes pouvant entra ner des d g ts irr versibles sur le mat riel Erreurs manifestes de raccordements entra nant des d g ts irr versibles sur le mat riel Projections ou ruissellements d eau l int rieur de l appareil pouvant entra ner des dysfonctionnements irr versibles sur le plan lectronique Reya International www reya com reya reya com V2 Page 15 09 07 08 Versione Italiana Avvertenze Prima dell impiego Questo manuale contiene informazioni essenziali e di vitale importanza Prima di impiegare il carica batterie necessario leggere completamente e comprendere il contenuto di questo manuale Nel caso non si comprendesse un concetto non esitare a contattare la REYA Prima dell installazione AI fine di evitare sovraccarichi o danni irreversibili all apparecchiatura si invita a seguire alla lettera le raccomandazioni che seguono Non installare questo apparato nei pressi di materiale infiammabile II proprietario potr richiedere l assistenza del concessionario della DOLPHIN o direttamente allo stabilimento e Non installare questo apparato nei pressi di fonti di calore e Non dovr neppure essere installato in ambienti chiusi o mal ventilati e Non ostruire le aperture di ventilazione e Montarlo in posizione verticale in modo da creare all interno del ventilatore una ventilazione naturale Si tenga conto che i collegamenti
18. ne dovr restare al suo posto e avvitato a fondo Manutenzione preventiva AI fine di evitare ogni rischio di scossa elettrica durante la manutenzione attenersi scrupolosamente alle raccomandazioni che prima di intraprendere qualsiasi azione di manutenzione e Staccare il cavo e Per evitare eventuali trasferimenti di energia staccare l accesso a DC o a BAT e Si invita ad attendere cinque minuti prima di accedere all interno della custodia i condensatori ad alta tensione richiedono tempo per scaricarsi e Sostituire i fusibili eventualmente bruciati con altri dalle identiche caratteristiche Reya International www reya com reya reya com V2 Page 16 09 07 08 Carica batterie Specifiche tecniche 12V 10A 12V 15A 12V 20A Tensione di entrata 230V 115V 230V 115V 98V 264V Frequenza di entrata 50Hz 60Hz 50Hz 60Hz 45Hz 65Hz commutazione115V 230V commutatore commutatore automatica Cos p 0 7 tipico 0 7 tipico 0 9 tipico Uscita 80 Potenza consumata 150W 225W 300W Potenza attiva 250VA 350VA 350VA Assorbimento di rete 1A 2A 1 5A 3A 3 7A 1 4A Fusibile T3A T4A T5A Numero di uscite 2 2 3 Curva di carica I U Uo 3 stadi Carica rapida livellata Tensione batteria Corrente massima Corrente batteria Selettore di carica 2 posizioni Posizione Norm Tutti i tipi Tutti i tipi Tutti i tipi
19. on conseguenti malfunzionamenti o guasti del dispositivo e L uso di una fonte di alimentazione inadatta come regola generale la tensione d entrata troppo alta pu provocare malfunzionamenti e guasti al dispositivo e Un sovraccarico elettrico accidentale o il fulmine provocano normalmente il malfunzionamento e il danneggiamento del dispositivo e La sostituzione dei fusibili della batteria con altri di tipo diverso da quelli raccomandati stesse caratteristiche pu provocare malfunzionamenti e guasti al dispositivo e Gli errori di collegamento ovviamente possono provocare malfunzionamenti e guasti al dispositivo e L acgua eventualmente entrata all interno della custodia pu provocare malfunzionamenti e guasti al dispositivo Reya International www reya com reya reya com V2 Page 22 09 07 08
20. tion par fusible batterie D faut g n ral Protection par fusible secteur Visualisation Led verte Chargeur ON Voyant orange Secteur pr sent Topologie Flyback 50KHz PFC 20A uniquement Climatique 0 C 50 C Stockage 20 C 70 C Humidit 10 90 sans condensation Protection lectronique Par tropicalisation Convection Naturelle Forc e Forc e CEM EN50081 1 EN50082 1 EN61000 3 2 S curit EN60335 1 Raccordements batteries Fastons 6 35 Fastons 6 35 Bornier vis DISTRIBUTION SECTEUR Reya International V2 WWW reya com Page 11 reyatwreya com 09 07 08 12V 10A 12V 15A 12V 20A Raccordements secteur Sur disjoncteur diff rentiel Raccordement PE Goujon M6 sur coffret Caract ristiques protection Disjoncteur 16A 6 5KA 30mA 4 modules Sorties utilisation 2 sorties prot g es Raccordements sorties Sur disjoncteur magn to thermique Raccordements PE Goujon M6 sur coffret Caract ristiques protection Disjoncteur 10A 6 5KA 1 module Coffret En aluminium peint Fixation Murale par 4 4mm Haut x larg x prof 280 x 270 x 100mm Poids 3Kg S curit ISO13297 Modes de fonctionnements 00000 00000 00000 Led verte Chargeur ON Voyant orange Secteur ON Secteur ON teint Armoire hors tension Chargeur ON teint e V rifier l tat du disjoncteur diff
21. usibili delle batterie con altri identici Batterie molto scariche e Caricare la batteria con una fonte esterna e Sostituire la batteria difettosa LED Corrente on acceso LED Carico on lampeggiante Ventola interna in funzione 12v15a amp 20a solomente e Carica batterie su BOOST e batterie in carica Ventola interna ferma e Caricabatterie su FLOAT e batterie in carica Reya International www reya com reya reya com V2 Page 19 09 07 08 Collegamenti della scheda del carica batterie Hav 230 V Conmutatore SUO m 250 Scheda 12V 20A Vista dall atto Scheda 12V TOA 15A _ vista dall alto PIRA D Norm Poza Norm Etes Il FELaibili batterie MOT SERV LOL DC C1 DCE OCA 02 DIO 02 03 Cavi batterie e Verificare l esatto collegamento di tutte le connessioni elettriche e E fondamentale che il cavo DC1 sia collegato alla batteria principale e Collegare i cavi DC2 e DC3 rispettivamente alla batteria del motore e a quella ausiliaria 12V 10A 12V 15A 12V 20A Sezione raccomandata 3mm 0 05in 4mm 0 06in 6mm 0 95in Lunghezza massima 1 5m 3 3lbs 1 5m 3 3lbs 1 5m 3 3lbs Fusibili In caso di necessita i fusibili devono essere sostituiti con altri con le stesse caratteristiche Altrimenti si rischiano dei danni irreversibili sul materiale 12V 30A 12V 40A 24V 20A Sezione di entrata T3A 250V T4A 250V T5A 250V Entrat
22. utiliser de pr f rence du c ble de type HO7RNF 12V 10A 12V 15A 12V 20A Section pr conis e 3 x 1 5mm2 3 x 1 5mm2 3 x 2 5mm2 Longueur max 5 m tres 5 m tres 5 m tres Garantie Afin de pr venir tout risque de mauvaise utilisation de l appareil lire attentivement la liste des v nements ou d fauts potentiels non couverts par la garantie produit Chute m canique de l appareil non emball pouvant entra ner des d formations irr versibles du coffret ainsi que le crash du ventilateur interne et de certains composants lectroniques Modifications du coffret per ages additionnels en particulier pouvant entra ner la diffusion de copeaux ou de limailles m talliques sur la carte lectronique et par voie de cons quence des dysfonctionnements ou d g ts irr versibles sur le mat riel Interventions ou modifications sur la carte lectronique pouvant entra ner des modes de fonctionnements non pr vus l origine et par voie de cons quence des dysfonctionnements ou d g ts irr versibles sur le mat riel Alimentation de l ensemble par une source non adapt e en r gle g n rale tension d alimentation secteur trop haute pouvant entra ner des d g ts irr versibles sur le mat riel Surtension secteur d origine accidentelle ou choc foudre entra nant en r gle g n rale des d g ts irr versibles sur le mat riel Remplacement des fusibles batterie en cas d inversion de po

Download Pdf Manuals

image

Related Search

Related Contents

Nyko Wand Action Pak  Installation - Canadian Appliance Source    Cisco Systems 1720 Network Router User Manual  TENSIOTRON TS 481  Manual - FlebitisZero  Bedienungsanleitung P6010D (pdf, 0,63MB, deutsch, englisch)  Remarque  Arke K03071 Installation Guide  NetScreen-Hardware Security Client User's Guide  

Copyright © All rights reserved.
Failed to retrieve file