Centrale Antifurto senza fili Wireless burglar alarm control panel
Contents
1. Fig 7 electronic I_ amp bell NOTE the system does not work if there is no power but it maintains the state it had before power cut and it restores it when the power returns AF3901R OUTDOOR SELF POWERED WIRELESS SIREN How to replace batteries 1 open the envelope by 2 open the metal protection by 3 replace the battery paying unscrewing the screw unscrewing the two screws attention to the right polarity N Technical data Fig 8 e Power supply 7 2 Vdc supplied with 2X Lithium Size battery 3 6 V 7 2 V 13 Ah code AVE AF915 Current demand when quiescent 100 yA max 7 2V Current demand under alarm 2 A max 7 2 V Blinker Xenon lamp with aluminous intensity equal to gt 2000 cd Operation 3 years for an average of 20 alarms per year and 1 con nection 1 disconnection a day before replacing the batteries e Acoustic signals with an increasing sound frequency 1400 to 1600 Hz gt for 1 second and a decreasing sound frequency 1600 to 1400 Hz for o 246 0 5 seconds Loudspeaker magnetic dynamic type Acoustic radiation pressure at 1 meter 115 dB Carrier frequency 433 92 MHz Signal coding 36 bit pre set random code Rated range of the connection 15 20 meters inside the house under normal conditions metal walls and anti seismic structures can reduce its range Protection against the enclosure opening Protection against removal p
2. Reference standard OperalioN iii ERRE Ra Leathe pag 22 Connection disconnection partial connection Ordinary operation Test state Alarm due to intrusion Alarm due to tampering 24 hour alarm state Scanner alarm state Alarm due to supervision detector out of order Alarm due to low battery Description of the front panel and signals 0 0 cece cece eee pag 24 Peripheral devices of the system cece pag 26 Remote control for connecting disconnecting and partially connecting the system Remote control to start robbery and panic alarms P IR detector Multi function door window detector Remote indicator of system state Outdoor self powered wireless siren Operation diagram seces nioen pag 36 DIRECTIONS The products must be sold in their original packing Where this is not the case the retailer and or the installer must apply and transmit the instructions for use supplied with the product to the user After ope ning the packing check the product s ntegrity in case of doubt do not use the equipment and consult skilled personnel Even when wrapped in its packing the equipment must be handled with care and sto red in a dry room at a temperature between and 40 C Remember e If not otherwise indicated the product must be used in dry rooms free of dust Use
3. 24h type channel for technical radio alarms Radio Tamper channel Connection partial connection disconnection through remote control code AF939R Panic alarm triggering through remote control AF938R Max number of different storable remote control or detector codes 64 Incorporated mechanical key Two intensity level incorporated buzzer to send alarms and to confirm user operations Battery current demand at rest 100 max Battery current demand in alarm condition 200 MA max Battery endurance more than 3 years with 10 alarm year cycles and 4 ON OFF operations a day Enclosure integrated wire antenna Lithium battery included to be connected to the card by means of flexible conductors provided with polarised connectors Protection against battery polarity reversal with polarised connector Classification of the radio Carrier frequency 433 92 MHz Transmitter maximum power 10mW Rated connection range 30 metres in normal living conditions metal walls or anti seismic structures may reduce the range Avoid installing the AF909RS and radio detectors closer than 2 cm from metal walls Climatic conditions Requirements and performances of the control panel complying with CEI 79 2 standards are assured according to the following climatic conditions e Reference temperature and relative humidity 25 C R U 65 e Operating ambient temperature range 10 C to 50 C e Max relative humidity 90 at 35 C e Altitude 2000 m a s
4. by means of a scanner If an attempt to reconstruct the code transmitted by the remote control is detected or a fixed carrier is transmitted the circuit signals an alarm The state of scanner alarm is indicated when the control panel is ON by the high intensity level inner buzzer switching ON for 15 s and by the SCANNER LED When the control panel is OFF only by the SCANNER LED Itis possible to exclude this function removing the jumper JP1 see picture 1 NOTE the tampering and the 24h alarms can be interrupted and or disconnected by turning the mecha nical key to PROGRAMMING or by pressing the GREEN push button of the AF939R remote control in this case there is no self cutting out after 3 alarms Alarm due to supervision detector out of order The detectors transmit the control panel periodically the so called presence signal The control panel checks every 3 hours and 50 minutes if all the detectors have transmitted the presence signal If a detector didn t transmit the presence signal the control panel starts the supervision alarm cycle in the following way Control panel condition Built in siren LED of the zone On Off Flashing for 15 s During connection Low level sound During disconnection for 155 Flashing for 30 s NOTE the control panel accepts non supervised detectors first generation as well Signal of low battery The state of the battery which needs to be repaired and or replaced is in
5. Fig 5 si accenderanno altenativamente i LED L1 verde e L2 rosso condizione di apprendimento codice 3 Trasmettere dalla centrale il segnale di disinserito centrale disinserita OFF eseguendo una com mutazione della chiave meccanica oppure disinserendo tramite telecomando la centrale stessa pre cedentemente inserita NOTA la centrale trasmette il segnale di disinserito ad ogni commutazione della chiave meccanica oppure in occasione di un disinserimento tramite telecomando 4 Ricevendo dalla centrale il segnale di disinserito l indicatore di stato impianto memorizza il codice che lo lega in modo univoco alla centrale stessa ed pronto per il normale funzionamento E 16 Descrizione funzionamento Il dispositivo riceve dalla centrale le segnalazioni di inserito disinserito e allarme e comanda le segnalazioni sul frontale come di seguito indicato vedere Fig 5 per identificazione LED LED COLORE ACCESO SPENTO LAMPEGGIANTE L1 inserito verde centrale inserita centrale disinserita L2 allarme rosso non in allarme allarme L3 alimentazione verde alimentazione presente alimentazione assente Schema applicativo L indicatore di stato impianto necessitando di una tensione di alimentazione compresa tra 8 e 24V c c c a 50Hz pu essere comodamente installato in parallelo al pulsante N A che comanda il campanello di casa fig 6 in caso di campanello elettromeccanico Fig 6 c
6. JP2 If this imput is not used JP2 has to be connected It is possible to use both NC imput and the magnet in order to con trol simultaneously the opening of a window and the movement of its roller blind The alarm signal will be generated by opening the window or by moving the roller blind The transmission of an alarm state is displayed by the LED on the detector body bali The table below shows all possible uses of an AF913R detector and its corresponding location Installation LOCATION Place the magnet provided with the device on the door or the window to protect while the AF913R detector must be placed on the frame If you want you can select the function of end of alarm by means of micro switch 3 ON end of alarm connected OFF end of alarm disconnected The anti shock protection can be connected by means of micro switch 4 ON anti shock connected OFF anti shock disconnected Adjust then the pulse count as indicated in fig 4 to produce a shock alarm after the chosen number of impulses Protection of doors and windows Protection of roller Enable the NC input by removing JP2 Connect the output contact usually an NC shutters walls contact of a vibrating inertial detector or a cord detector for roller shutter protection external connection of to the NC input of the AF913R detector s terminal board inertial or cord Adjust the pulse count as indicated in fig 4 to produce an alarm after the chosen detecto
7. PROG 3 premere il pulsante di reset previsto sulla scheda della centrale vedi Fig 1 al fine di azzerare la memoria della centrale sar emesso un beep di conferma 4 premere contemporaneamente i pulsanti rosso e verde del telecomando 5 la centrale conferma l avvenuta memorizzazione del codice del telecomando con un beep di confer ma In caso il codice sia presente nella memoria della centrale telecomando gi memorizzato saranno emessi N 5 beep di conferma La programmazione di ulteriori telecomandi possibile senza aprire la centrale ponendo la chiave mec canica in programmazione ed effettuando l operazione N 4 Volendo invece cancellare tutti i telecomandi precedentemente memorizzati e rimemorizzare solo quelli voluti operare come segue 1 porre la chiave meccanica in PROGRAMMAZIONE 2 premere per 15 secondi contemporaneamente i due pulsanti di un telecomando gi memorizzato 3 la rimemorizzazione dei telecomandi richiede solo l operazione dal punto 4 senza bisogno di aprire la centrale Nota con questa operazione possibile cancellare dalla memoria di centrale codici di telecomandi eventualmente smarriti AF938R Telecomando per attivazione dell allarme panico A differenza del modello per l attivazione dell impianto predisposto per attivare l allarme panico E di colore rosso ed ha due pulsanti rossi Nota Vedere paragrafo DESCRIZIONE DEL FUNZIONAMENTO pag 4 per dettagli sugli eventi di allarme pani
8. TECH ALARM Each LED remains on until the green push button is pressed 4 turn on the power to the detector by means of the corresponding battery while the LED of the chosen channel is on At the first supply each detector transmits its code for 30 seconds and so the control panel can store the detectors code in its memory and couple it with the selected channel 5 a beep indicates that the control panel has stored the detector s code this beep is followed by 5 short beeps By pressing the TAMPER push button of the detector this sequence can be interrupted 6 now to check the cover range the detector stays in the test condition for 2 minutes The detector is now ready to operate Operation 3 minutes after connecting the battery the detector is ready to start If a movement is detected it starts the alarm To reduce the battery current demand the alarm is followed by a pause of two minutes Note In a quiescent condition the LED is always off It switches on only if an alarm is detected or during the test Test In order to carry out the walk test it is necessary to select the test function on the detector pressing the push button test located in the lower part of the plastic housing The pause of two minutes after the detection will be excluded for two minutes and the LED on the detector will be enable A beep indicates the passage of the detector to the test function Adjust the sensitivity of the detector to the minimum and in the
9. of battery discharged 3 beeps produced by the detector at each alarm transmission indicate that the battery needs to be repla ced over one month before its complete discharge AF942R REMOTE INDICATOR OF SYSTEM STATE Fig 5 L1 connected L2 alarm L3 power 44mm m m __ Technical data e Power 8 to 24 V dc or ac 50Hz e Current demand 5 mA quiescent 18 mA with LED s on e Enclosure ABS white 44 x 67 x 19 mm e Installation to the wall by screws opening for cable input on the bottom e Lid fixed by release on a support e Carrier frequency 433 92 MHz e Connection nominal range 30 m under normal conditions in a house metal walls or anti seismic structures can reduce the range Avoid their installation at less than 2 cm from the metal walls Reference standards AF942R complies with the basic requirements of the 99 05 CE Directive Technical Standards EN60950 1996 along with their further amendments ETS300683 1997 EN300220 1 were applied Warning the device must be used for low voltage safety connections Connection to dangerous voltage circuits may be hazardous Programming 1 Turn on the power to the system the LED L3 green will switch on 2 Press the internal reset push button Fig 5 and the LED L1 green and L2 red will switch on alter natively the code learning sequence is carried out 3 Transmit the signal of disconnected from the control pan
10. supervision and battery level to the control panel every 72 minutes Temperature compensation circuit features Quartz transmission at 433 92 MHz max power 10mW Signal coding 36 bit random code previously programmed Over 68 billion combinations Working capacity over 40 m in open space 30 m approx In domestic environments Dimensions 132x65x46 mm Installation for safety reasons install the device in a zone not easily accessible to the user Reference standards The AF968R detector complies with the basic requirements of the 99 05 CE Directive Technical Standards EN60950 1996 along with their further amendments ETS300683 1997 EN30022 1 were applied the basic radio tests and specifications of the radio device category selected by the chosen noti fied institution were carried out No of the notified institution 0682 The use of the product on the Italian Territory is subject to the rules and requirements of the Postmaster General no 615 art 334 and next Programming To store the volumetric detector code in the control panel memory proceed as follows 7 turn the mechanical key to programming The PROG LED will switch on 2 open the control panel enclosure 3 beeps are produced for confirmation and the LED ZONE A channel 1 switches on 3 press the GREEN push button of an already stored AF939R remote control all the line LED s will switch on progressively that is line 1 2 3 4 5 6 7 8 9 PANIC
11. tecnico consigliabile utilizzare l ingresso NA che esclude automatica rivelatori per allarmi tecnici mente il contaimpulsi Installazione Aprire il rivelatore facendo leva con un cacciavite sull anello di chiusura Fissare sul muro o sull infisso il corpo del rivelatore con viti ove utilizzata la protezione antiscasso Se installato su vetro utilizzare sili cone e non biadesivo Programmazione La sequenza di programmazione uguale a quella dei rivelatori volumetrici AF968R riportata a pag 10 La programmazione del microswitch 3 deve essere effettuata prima di effettuare la sequenza di program mazione del rivelatore Qualora la funzione del microswitch 3 dovesse cambiare necessario rieffettuare la sequenza di programmazione del rivelatore La programmazione dei microswitch 1 2 4 pu essere variata senza rieffettuare alcuna programmazione Nota volendo utilizzare il rivelatore perimetrale multifunzione per collegare via radio alla centrale un rivelatore per allarmi tecnici si dovr procedere alla programmazione dello stesso sul canale TEC ALARM Allarme manomissione In qualunque monento aprendo il contenitore dell apparecchio si ha la trasmissione dell allarme mano missione tramite apposito microswitch Tramite un secondo microswitch posto sul retro della scheda il rivelatore trasmette anche l allarme rimozione L allarme rimozione pu essere attivato o disattivato tramite il ponticello JP1 vedere fig
12. without opening the control panel but just turning the mecha nical key to programming and carrying out operation no 4 If all the previously stored remote controls must be reset to store only a few of them proceed as follows 7 turn the mechanical key to PROGRAMMING 2 press the two push buttons of an already stored remote control simultaneously for 15 seconds 3 there is no need for the control panel to be opened again as the remote controls can be re stored just by repeating operation the sequenze from point N 4 Note this operation can be carried out to cancel the codes of lost remote controls from the memory of the control panel AF938R Remote control to start panic alarm Unlike the model for starting the system this mode has been designed to start the panic alarm It is red coloured and has two red push buttons Note See paragraph OPERATION page 22 for details concerning panic alarm Programming To store the remote control code in the control panel memory proceed as follows 7 turn the mechanical key to programming The PROG LED will switch on 2 open the control panel enclosure 3 beeps are produced for confirmation and the LED ZONE A channel 1 will switch on 3 press the GREEN push button of an already stored AF939R remote control all the line LED s will switch on progressively that is line 1 2 3 4 5 6 7 8 9 PANIC TECH ALARM Each LED remains on until the green push button is pressed 4 select the PA
13. 24h Non in allarme larme memorizzato TAMPER Allarme manomiss linea 24h Non in allarme larme memorizzato Sostituzione della batteria Per sostituire la batteria al Litio interna procedere come segue a mettere la chiave meccanica in posizione PROG e svitare la vite di chiusura posta sotto l apposito tappo b sostituire la batteria interna codice di ricambio AF915 c richiudere il contenitore e rimettere la chiave meccanica in posizione ON PERIFERICHE DEL SISTEMA AF939R TELECOMANDO per inserimento disinserimento e parzializzazione del sistema Fig2 Sostituzione della batteria Per la sostituzione della batteria a togliere l elastico di chiusura Fig 2 b rimuovere la batteria e sostituirla facendo attenzione alle polarit c richiudere con l apposito elastico a b FM a pe og Pulsante rosso _ Pulsante verde x Caratteristiche tecniche e Alimentazione pila alcalina 12V standard 23M VR22 e Assorbimento 20 mA in trasmissione e Autonomia dipende dal numero di manovre 6 mesi minimo e Funzioni operative inserimento impianto disinserimento impianto parzializzazione impianto e Caratteristiche R F trasmissione quarzata a 433 92 MHZ potenza max 10mW e Codifica segnali codice random 36 bit preimpostato Oltre 68 miliardi di combinazioni e Portata utile pi di 15 m in aria libera Circa 10 m in ambienti residenziali e D
14. 4 15 fom Allarme per pila scarica La necessit di sostituzione della pila segnalata da 3 beep emessi dal rivelatore ad ogni trasmissio ne d allarme oltre un mese prima della scarica totale AF942R INDICATORE REMOTO DI STATO IMPIANTO Fig 5 Alimentazione L1 inserito L2 allarme 44mm L3 alimentazione Caratteristiche tecniche Alimentazione da 8 a 24 V c c o c a 50Hz Assorbimento 5mA a riposo 18mA con led accesi Contenitore ABS Bianco 44 x 67 x 19 mm Possibilit di installazione con viti a parete apertura per ingresso cavi sul fondo Coperchio fissato a scatto su base Frequenza della portante 433 92 MHz Portata nominale del collegamento 30 metri in condizioni normali nell ambiente abitativo pareti metalliche o strutture antisismiche possono ridurre la portata Evitare l installazione a meno di 2cm da pareti metalliche Riferimenti normativi Il rivelatore AF942R conforme ai requisiti essenziali fissati dalla direttiva 99 05 CE e ad esso sono state applicate le Norme tecniche EN60950 1996 e successive varianti ETS600683 1997 EN300220 1 Attenzione il dispositivo previsto esclusivamente per collegamenti a bassissima tensione di sicurez za il collegamento con circuiti a tensione pericolosa pu provocare pericolo Programmazione 1 Applicare l alimentazione all apparecchio si accender il LED L3 verde 2 Premere il pulsante di reset interno
15. 5 c Close again the enclosure and move the mechanical key to ON PERIPHERAL DEVICES OF THE SYSTEM AF939R REMOTE CONTROL for connecting disconnecting and partially connecting the system How to replace batteries a remove the elastic band Red push button G reen push button b remove the battery and replace it paying Fig 2 attention to the right polarity c close with the elastic band Technical data a b FM a AN Power alkaline battery 12 V standard 23M VR22 Current demand 20 mA during transmission Life it depends on the number of operations minimum 6 months Operating functions connection of the system disconnection of the system partial connection of the system R F features Quartz transmission at 433 92 MHz max power 10mW e Signal coding 36 bit pre set random code Over 68 billion combinations e Working capacity over 15 m in open space 10 mt approx In domestic environments e Dimensions 78x24 5x21 mm Reference standards Remote controls AF938R and AF939R comply with the basic requirements of the 99 05 CE Directive Technical Standards EN60950 1996 along with their further amendments ETS300683 1997 EN300220 1 were applied the basic radio tests and specifications of the radio device category selected by the cho sen notified institution were carried out No of the notified institution 0682 The use of the product on the Italian Territory is subject to the rul
16. ASHING Function Colour OFF system disconnected PROG Yellow Programming and or test Ordinary operation TXON SCANNER Temper Zone At Zone A2 Zone A3 Zone B4 Zone B5 Zone B6 Zone C7 Zone C8 Zone C9 PANIC Transmission under way Transmission not under way Scanner alarm Not under alarm or cut out Open tamper Closed tamper Zone A1 under alarm Zone A1 cut out or not under al arm stored Zone A2 under alarm Zone A2 cut out or not under al Zone A3 under alarm Zone A3 cut out or not under al Zone B4 under alarm Zone B4 cut out or not under al Zone B5 under alarm Zone B5 cut out or not under al arm stored arm stored arm stored arm stored arm stored arm stored arm stored Zone B6 under alarm Zone B6 cut out or not under al Zone C7 C under alarm Zone C7 cut out or not under al Zone C8 C under alarm Zone C8 cut out or not under alarm arm stored arm stored arm stored arm stored Zone C9 C under alarm Zone C9 cut out or not under alarm Panic alarm 24h line Not under alarm Technical alarm 24h line Not under alarm Tamper alarm 24h line Not under alarm E E E F EE E E F S EE E SSS Sl Sl Sl Sl Sl SlSlSl S How to replace batteries To replace the inside lithium battery proceed as follows a Move the mechanical key to PROG Unloosen the faste ning screw seated under the special plug b Replace the inside battery spare part code AF91
17. E INTERRUTTORI Centrale Antifurto senza fill SUPERVISIO N ATA W ireless burglar alarm control panel SUPERVISED cop AF909RS Centrale Antifurto senza fill SUPERVISIO N ATA cop AF909RS INDICE e OR ear oR ae pag 3 Caratteristiche tecniche s pag 3 Condizioni climatiche Riferimenti normativi Descrizione pag 4 Inserimento disinserimento parzializzazione Funzionamento normale Condizione di TEST Condizione di allarme intrusione Condizione di allarme per manomissione TAMPER Condizione di allarme 24h Condizione di allarme scanner Condizione di allarme supervisione guasto rivelatori Segnalazione batterie scariche Descrizione frontale e 56 8 pag 7 ita pag 9 Telecomando per inserimento disinserimento e parzializzazione dell impianto Telecomando per attivazione degli allarmi rapina e dell allarme panico Rivelatore IR P Rivelatore perimetrale multifunzione Indicatore remoto di stato impianto Sirena via radio autoalimentata per esterni Schema applicatiVo i iii pe pag 21 AVVERTENZE prodotti devono essere commercializzati in confezione originale in caso contrario al rivenditore e o installatore fatto obbligo di appl
18. NIC channel in order to store the code of the AF938R 5 press the push button simultaneously for 5 seconds while the LED of the PANIC channel is on 6 a beep indicates that the remote control code has been stored If the code exists in the control panel memory remote control already stored 5 beeps will be produced for confirmation By pressing one of the two red push buttons during the normal operation a panic alarm will be started AF968R P IR DETECTOR Fig 3 AF968R Internal view AF968R Standard lens Sensitivity adjustment VY TAMPER Nae 2m Pulse count F T push button 1m 5m 10m 15m Opening of enclosure How to replace batteries To replace the battery remove the discharged battery after opening the enclosure Observe the given polarities Technical data Power alkaline battery 9 V standard size 6LR16 or lithium battery SAFT 9 V Current demand 18 during stand by 20 mA during transmission Life 18 months with an alkaline battery 30 to 36 months with a lithium battery Position Wall mounting better if in a corner at a height of 2 to 2 30 meters Covered zone 100 opening for 12 m range 20 beams on 3 levels Sensitivity adjustable by trimmer from 30 to 100 Alarm detector programmable by pulse count 1 or 3 it can be selected by the pulse count jumper Test detection of movement displayed by LED Transimission of the presence signal
19. OR TELEPHONE S DIALER AF53902R J a A i e a AF913R MULTI FUN CTION DOORW IN DOW DETECTORS 2 N w SELF PO W ERED SIREN AF53901R AF939R REMOTE CONTROL CONNECTION DISCONNEC TION PARTALCON NECTION
20. aline battery 30 to 36 months with a lithium battery e Operational functions signal of open door signal of closed door shock alarm attempted intrusion alarm by pulse counter by external connection of inertial detectors technical alarm by external connection of technical detectors e Transmission of the presence signal supervision and battery level to the control panel every 72 minu tes features Quartz H F transmission at 433 92 MHz max power 10mW e Signal coding 36 bit pre set random code Over 60 billion combinations e Working capacity over 40 m in open space 30 m approx in residential environments e Dimensions 135x32x27 Reference standards The AF913R detector complies with the basic requirements of the 99 05 CE Directive Technical Standards EN60950 1996 along with their further amendments ETS300683 1997 EN300220 1 were applied the basic radio tests and specifications of the radio device category selected by the chosen noti fied institution were carried dout No of the notified institution 0682 The use of the product on the Italian Territory is subject to the rules and requirements of the Postmaster General no 615 art 334 and next Operation The AF913R detector can carry out various operational functions that can be selected by means of special micro switches As indicated in Figure 4 it is provided with a REED contact operated by an external magnet supplied with the device which
21. allarme scanner segnalata a centrale inserita dall attivazione della sirena interna ad alta intensit per 15 s e dal LED SCANNER a centrale disinserita solo dal LED SCANNER E comunque possibile escludere la funzione di rivelazione allarme scanner togliendo il ponticello JP1 posto sulla scheda elettronica vedi fig 1 Nota gli allarmi manomissione e 24h sono interrotti e o disabilitati ponendo in PROGRAMMAZIONE la chiave meccanica oppure premendo il tasto VERDE del telecomando AF939R in questo caso non esiste autoesclusione dopo 3 allarmi Condizione di allarme supervisione guasto rivelatori rivelatori trasmettono alla centrale periodicamente un segnale di presenza La centrale ogni 3 50h ne verifica l avvenuta ricezione Se il segnale di presenza viene a mancare la centrale segnala la condizione di allarme come di seguito riportato Stato centrale Sirena interna alla centrale LED di zona Inserita Disinserita Lampeggiante per 15 5 All atto dell inserimento Segnalazione bitonale a bassa intensit All atto del disinserimento per 155 Lampeggiante per 30 5 Nota a centrale esce dalla fabbrica con la funzione di supervisione disinserita Per inserirla procedere come segue 1 porre la chiave meccanica in prog 2 aprire il contenitore 3 premere per 10s i tasti rosso e verde di un telecomando memorizzato 4 all accensione del LED tamper la funzione di supervisione inserita Per disinserire succes
22. ampanello I D _T elettromeccanico A Nel caso di campanelli elettronici dispositivi aa alta impedenza necessario alimentare il dispositivo direttamente dal secondario del trasformatore del campanello fig 7 Fig 7 campanello 3 elettronico In alternativa possibile alimentare l apparecchio con tensione dalle caratteristiche sopra riportate NOTA il dispositivo non funziona in caso assenza rete ma conserva il suo stato precedente alla man canza e lo ripristina invariato al rientro rete AF53901R SIRENA VIA RADIO AUTOALIMENTATA PER ESTERNI Sostituzione della batteria 1 aprire l involucro svitando la 2 aprire la protezione metalli sostiture la batteria facendo vite ca svitando le due viti attenzione alle polarit I Caratteristiche tecniche fig 8 gt e Alimentazione fornita esclusivamente da batteria al litio 2 x Litmium size da 3 6V 7 2V 13Ah cod Ave AF915 in dotazione Non necessita di alcun collegamento via filo e Assorbimento a riposo 100 pA max 7 2 V e Assorbimento in allarme 2 A max 7 2 V Lampeggiatore realizzato con lampada allo Xenon avente intensit lumi nosa gt 2000 cd Autonomia di funzionamento prima della sostituzione delle batterie con una media di 20 allarmi anno e 1 inserzione 1 disinserzione al gior no 3 anni i e Segnalazione acustica con
23. case of noisy environment turn the pulse count jumper to position 3 the alarm starts after 3 steps approximately Tampering alarm At any moment by opening the enclosure the tampering alarm starts Alarm of battery discharged 3 beeps produced by the detector together with the alarm signal indicate that the battery needs to be replaced one month before its complete discharge AF913R AND AF913R M MULTI FUNCTION DOOR WINDOW DETECTOR Fig 4 How to replace batteries Buzzer signalling a discharged barry H 5 mm max JP N umper for enabling NC imput Connected NC input not enabled Disconnected NC input enabled External detector contact by wire JP1 Jumper for alarm interruption removal d 1 af Connected removal alarm disconnected Disconnected removal alarm connected C INC JHE 12 12 12 12 8 B B ii 3ENDOFAIARM 2 4 8 BATTERY HOUSING 1 pulse count Technical data a remove the elastic band b remove the battery and c close with the elastic band replace it paying attention to the right polarity Power alkaline battery 9 V standard size 6LR16 or lithium battery SAFT 9 V e Current demand 18 during stand by 20 mA during transmission Life 18 months with an alk
24. co Programmazione Per memorizzare il codice del telecomando nella memoria della centrale procedere come segue 1 porre la chiave meccanica in programmazione si accender il LED PROG 2 aprire il contenitore della centrale saranno emessi 3 beep di conferma ed acceso il LED della ZONA Acanale 1 3 premere il pulsante VERDE di un telecomando AF939R gi memorizzato si verifica l accensione in sequenza di tutti i LED di linea cio linea 1 2 3 4 5 6 7 8 9 PANIC TEC ALARM Ogni LED resta acceso finch non si preme nuovamente il tasto verde 4 selezionare il canale PANIC al quale abbinare il telecomando AF938R 5 premere contemporaneamente i pulsanti per 5 s mentre il LED del canale PANIC acceso 6 la centrale conferma l avvenuta memorizzazione del codice del telecomando con un beep di confer pesi 10 ma In caso il codice sia presente nella memoria della centrale telecomando gia memorizzato saranno emessi N 5 beep di conferma Durante il normale funzionamento la pressione di uno dei due pulsanti rossi provocher l allarme panico AF968R RIVELATORE IR P Fig 3 AF968R vista interna AF968R Lente standard Regolazione sensibilit ees 150 TAMPER 2m Conteggio T impulsi im 5m 10m 15m Pulsante di test Sostituzione batterie Per la sostituzione della batteria rimuovere l involucro come indica to e sostituire le batterie facendo attenzione alla polari
25. dicated by the control panel one month before its complete discharge as follows Control panel condition Built in siren LED of the zone On High level sound for 15 s Off All LEDs flashing Low level sound for 15s for 15s During disconnection All LEDs flashing for 30 s During connection Alarm due to low detector AF913R AF913R M AF968R battery Low detector battery condition is reported on the control panel during connection and during disconnec tion in the following way e Led of the zone Low level sound for 15 s When the control panel is OFF low detector battery condition is reported on the control panel only by the LED of the zone Signal of open door connection not ready If a door window detector duly programmed to tran smit the signal of open door by means of the micro switch 3 see page 31 32 detects the state of open door when the system is connected on the control panel the following signal will be released during the exit time the LED relating to the corresponding channel flashes and a beep of about 10 seconds is produced At the end of the exit time the alarm signal will NOT be produced DESCRIPTION OF THE FRONT PANEL AND SIGNALS The table here below shows the meaning of the control panel optical alarms in the four possible states Fig 1 Reset push button PI n Mechanical key y ee TEC PANIC ALARM TAMPER SCANNER TX ON AF909RS BS ave LED FL
26. ecnici e Invio segnale di presenza supervisione e di batteria scarica ogni 72 minuti e Caratteristiche R F trasmissione quarzata a 433 92 MHZ potenza max 10mW e Codifica segnali codice random 36 bit preimpostato Oltre 60 miliardi di combinazioni e Portata utile pi di 40 m in aria libera Circa 30 m in ambienti residenziali e Dimensioni 135x32x27 mm Riferimenti normativi Il rivelatore AF913R conforme ai requisiti essenziali fissati dalla direttiva 99 05 CE e ad esso sono state applicate le Norme tecniche EN60950 1996 e successive varianti ETS600683 1997 EN300220 1 e la serie di prove radio essenziali e specifiche della categoria delle apparecchiature radio individuate dall or ganismo notificato prescelto N organismo notificato prescelto 0682 L uso del prodotto sul territorio italiano soggetto alle regolamentazioni del codice postale e delle tele comunicazioni n 615 art 334 e successivi Descrizione funzionamento Il rivelatore AF913R ha la possibilit di essere utilizzato in varie funzioni operative selezionabili tramite appositi microswitch Come indicato in fig 4 equipaggiato internamente con un contatto reed ad ampolla azionato da un magnete esterno fornito in dotazione per essere installato a protezione di porte e finestre In questo caso il magnete dovr essere installato sulla porta o finestra da proteggere e il rivela tore sull infisso In condizioni di porta chiusa come indicato dal
27. el control panel disconnected by turning the mechanical key or disconnecting the previously connected control panel by the remote control NOTE Each time the mechanical key is turned or every time a disconnection is carried out by means of the remote control the control panel transmits the signal of disconnected 4 Once the system state indicator has received the signal disconnected from the control panel it sto res the code linking it to the control panel and so it is ready to operate Operation The device receives the signals of connected disconnected and alarm from the control panel and transmits the signals on the front panel as described below see Fig 5 for LED description Operation diagram COLOUR ON OFF FLASHING green control panel connected control panel disconnec red no alarm alarm green power on power off As the system state indicator needs a current between 8 and 24V dc or ac 50Hz it can be installed in parallel to the N O push button which controls the door bell Fig 6 if this is an electromechanical bell In the case of electronic bells high impedance devices the device must be powered directly from the Fig 6 electromechanical secondary of the bell s transformer Fig 7 As an alternative the system can be powered using the voltage with the above characteristics
28. eration All signals coming from the control panel activate the following siren functions CONTROL PANEL SIGNAL FUNCTIONS CARRIED OUT BY THE SIREN CONNECTED control panel connected ON 4 beeps flashing light DISCONNECTED control panel disconnected OFF 1 beep flashing light ALARM Flashing light and low intensity acoustic signal for 10 seconds followed by flashing light and high intensity acoustic signal 115 db at 1 for 3 minutes NOTE the volume of the low intensity acoustic signal can be adjusted by means of a potentiometer pla ced on the electronic cara Tampering alarm The enclosure is equipped with two self protecting contacts one for protection against opening and the other against removal The tampering alarm is not transmitted to the control panel by the siren Anti removal contact preparation To perform the anti removal contact it is necessary to keep closed the anti remo val contact seated on the rear side of the siren by fixing a screw in the wall in the position shown by the drilling jig and leaving it project by 10 mm that will press the pin brass coloured and therefore close the contact as shown in the figure Alarm of battery discharged A series of beeps produced for 30 seconds when connecting and disconnecting the system indicate that the battery needs to be replaced 39 OPERATION DIAGRAM TO THE TELEPHONE SET TO THE TELEPHONE JACK AF968R pe IRP RADIO CONNECT
29. es A B C can be inserted individually as follows 1 press the RED and GREEN push buttons of the remote control simulta neously the LED s of the zone A channels 1 2 and 3 zone B channels PARTIAL 4 5 and 6 and zone C channels 7 8 and 9 will flash progressively CONNECTION 2 to disconnect the desired zone press the GREEN or the RED push button when their corresponding LED flashes The end of this sequence will be signalled by 3 beeps The LEDs corresponding to the connected zones remain on until the end of the output time Ordinary operation The operation is possible only if the mechanical key is in the ON position When turning the key to the PROG position all alarms and connection disconnection operations are disconnected and programming maintenance and testing can now be carried out If the control panel is disconnected the flashing LED s indicate that the alarm has been stored This flashing lasts 30 seconds after disconnection and it can be restored each time you press the GREEN push button from the remote control When the system is subsequently connected the stored alarms are cancelled by pressing the RED push button of the remote control Every time the system is connected the reception of all signals coming from the zone intrusion detectors is disconnected for 60 seconds exit time TEST State By turning the mechanical key to the Programming position the PROG LED switches ON and the con
30. es and requirements of the Postmaster General no 615 art 334 Programming As described in the chapter relating to its operation this remote control connects disconnects and par tially connects the system It is provided with two push buttons a green and a red one To store the remote control code in the con trol panel memory proceed as follows 7 turn the mechanical key to PROGRAMMING the PROG LED will switch on 2 open the control pane enclosure 3 beeps are produced for confirmation and the LED ZONE A1 swit ches on as this is the first condition to start programming Note if the control pane enclosure is open and the mechanical key is already in the PROGRAMMING position during the first power supply the control panel automatically enters the state of start program ming If the mechanical key is in the ON position the control panel enters the state of start programming by passing from ON to PROG 3 press the reset push button indicated on the control panel card see Fig 1 to reset the control panel memory a beep will be produced for confirmation 4 press the red and green push buttons of the remote control simultaneously 5 the control panel confirms that the remote control code has been stored by producing a beep for confir mation If the code exists in the control panel memory remote control already stored 5 beeps will be produced for confirmation Other remote controls can be programmed
31. frequenza del suono crescente da 1400 a 1600 Hz per 1 5 e poi decrescete da 1600 a 1400 Hz per 0 5 s Altoparlante magneto dinamico Pressione acustica a 1 metro 115 dB Frequenza della portante 433 92 MHZ Codifica segnali codice random 86 bit preimpostato Portata nominale del collegamento 15 20 metri in condizioni normali nell ambiente abitativo pareti metalliche o strutture antisismiche possono ridurre la portata Protezione contro apertura involucro Protezione contro asportazione Protezione contro inversione batteria tramite connettore polarizzato Calotta e fondo in policarbonato Grado di protezione IP34 Controcoperchio per antischiuma e protezione della tromba in metallo Temperatura 20 C 55 C Umidit relativa a 35 C 95 max ow 2985 e 332 Riferimenti normativi Il dispositivo AF53901R conforme ai requisiti essenziali fissati dalla direttiva 99 05 CE e ad esso sono state applicate le Norme tecniche EN60950 1996 e successive varianti ETS600683 1997 EN300220 1 Programmazione 1 Collegare le batteria al litio tramite l apposito connettore La sirena si pone in stato di riposo in attesa del codice radio che la legher univocamente alla centrale radio dell impianto in installazione 2 Trasmettere dalla centrale il segnale di disinserito centrale disinserita OFF eseguendo una com mutazione della chiave meccanica oppure disinserendo tramite telecomando la centrale stessa prece denteme
32. icare e di trasmettere all utilizzatore le istruzioni d uso che accompagnano il prodotto Dopo aver aperto l imballaggio assicurarsi dell integrit dell apparecchio nel dubbio non utilizzare l apparecchio e rivolgersi a personale professionalmente qualificato L apparecchio anche se imballato deve essere maneggiato con cura e immagazzinato in luogo asciutto ad una temperatura compresa tra 5 40 C Si ricorda inoltre e Il prodotto se non diversamente specificato destinato all utilizzo in luoghi asciutti e non polverosi Per ambienti particolari utilizzare prodotti specifici e Nel caso di prodotti alimentati con batterie quando queste sono scariche vanno sostituite con un modello equiva lente e smaltite secondo le vigenti norme Nel caso dovesse verificarsi fuoriuscita del liquido sostituirle immediata mente pulire accuratamente l alloggio delle batterie proteggendosi le mani con guanti al silicone In caso di contat to con il liquido lavarsi accuratamente le mani e Nel caso di prodotti utilizzanti batterie al Litio unitamente a quanto sopra tenere conto che queste presentano peri colo d esplosione devono quindi essere sostituite da personale specializzato nae INTRODUZIONE AF909RS una centrale antifurto completamente senza fili a 9 zone che permette esclusivamente la con nessione radio dei rivelatori di intrusione Dispone inoltre di tre canali 24h dedicati a allarme panico allarme tecnico gas fumo ac
33. imensioni 78 x 24 5 x 21 mm Riferimenti normativi telecomandi AF938R e AF939R sono conformi ai requisiti essenziali fissati dalla direttiva 99 05 CE e ad essa sono state applicate le Norme tecniche EN60950 1996 e successive varianti ETS600683 1997 EN300220 1 e la serie di prove radio essenziali e specifiche della categoria delle apparecchiature radio individuate dall organismo notificato prescelto N organismo notificato prescelto 0682 Luso del prodotto sul territorio italiano soggetto alle regolamentazioni del codice postale e delle tele comunicazioni n 615 art 334 e successivi Programmazione Questo telecomando permette come descritto nel paragrafo descrizione del funzionamento di inserire disinserire e parzializzare l impianto Dispone di due pulsanti uno verde e uno rosso aoe Per memorizzare il codice del telecomando nella memoria della centrale procedere come segue 1 porre la chiave meccanica in PROGRAMMAZIONE si accende il LED PROG 2 aprire il contenitore della centrale saranno emessi 3 beep di conferma ed acceso il LED della ZONA A canale 1 condizione di inizio programmazione Nota all atto della prima alimentazione con contenitore centrale aperto se la chiave meccanica gi in posizione PROGRAMMAZIONE la centrale si predispone automaticamente in questa condizione Se la chiave meccanica in posizione ON la centrale si predispone in condizione di inizio programmazione commutando da ON a
34. itted by the corresponding detectors by radio in the case of tam pering with its enclosure each detector transmits the tampering signal by radio If the control panel and or the detectors are tampered with the alarm sequence will be the same as for the intrusion alarm provided that the control panel is connected but if the control panel is disconnected the alarm sequence is different as the AF53901R siren connected by radio to the control panel will not be started The tamper alarm coming from a radio detector is displayed on the control panel by the tamper LED and the LED of the corresponding channel NOTE before replacing the batteries of the radio detectors turn the mechanical key to PROGRAMMING thus avoiding any optical acoustic tampering signal 24 hour alarm state By programming several multi function door window detectors and or remote controls the following alarms can be connected regardless of the connected or disconnected state of the control panel see table below It activates e the internal buzzer high intensity acoustic signal for 15 seconds PANIC e the AF53901R siren which is connected by radio to the on system control panel e The AF53902R radio telephone dialler if any TECHNICAL ALARM It activates the internal buzzer low intensity acoustic signal Scanner alarm state The control panel is equipped with a special circuit that can detect all attempts at tampering carried out
35. l Reference standards The AF909RS control panel complies with the basic requirements of the 99 05 CE Directive Technical Standards EN60950 1996 along with their further amendments ETS300683 1997 EN300220 1 were applied the basic radio tests and specifications of the radio device category selected by the chosen noti fied institution were carried out No of the notified institution 0682 The use of the product on the Italian Territory is subject to the rules and requirements of the Postmaster General no 615 art 334 and next OPERATION Connection disconnection partial connection Connection disconnection and partial connection of the system can be carried out as follows by means of the remote control and only if the mechanical key is in the ON position Move the key to the PROG position to turn the system to the programming and TEST state Press the RED push button of the remote control all the Zone LEDs will be FULL turned on A B C and 3 beeps for confirmation will be heard The LED s CONNECTION turn off once the exit time is passed that is after 60 seconds At the end of the exit time LEDs remain ON Press the GREEN push button of the remote control before entering the pro tected zone a long beep for confirmation will be heard the LEDs of the channels which have stored alarms will flash some alarm devices repeat the optical sound signals which are typical of the ON OFF operations DISCONNECTION The Zon
36. l emissione dei 3 beep LED relativi alle zone inserite rimarranno accesi fino al termine del tempo d uscita Funzionamento normale Il funzionamento abilitato solo con chiave meccanica in posizione ON La commutazione della chiave in PROG disabilita gli allarmi e le manovre di inserimento disinserimento dell impianto rendendo possibili gli interventi per programmazione manutenzione e test Con centrale disinserita i led eventualmente lampeggianti indicano allarme memorizzato Tale lampeggio continua per 30 dopo la manovra di disinserzione e pu essere ripristinato ad ogni nuova pressione del pulsante VERDE del telecomando ow ni La memorizzazione degli allarmi viene annullata alla successiva inserzione dell impianto premendo il pulsante ROSSO del telecomando L inserimento dell impianto disabilita per 60 secondi tempo di uscita la ricezione di tutti i segnali prove nienti dai rivelatori antintrusione di zona Condizione di TEST Ponendo la chiave meccanica in posizione Programmazione il LED PROG si accende fisso e la centrale automaticamente in condizione di TEST Quando riceve un segnale di allarme via radio emette un Beep di conferma e si accende il LED del canale interessato Manomettendo un rivelatore si accendono contemporaneamente il LED del canale interessato e il LED TAMPER con l emissione di un beep Condizione di allarme intrusione Con centrale inserita il segnale di allarme in
37. la fig 4 la distanza tra il rivelatore e il magnete non deve superare i 5 mm Allontanando il magnete dal rivelatore il rel reed aprendo il proprio contatto generer l allarme che sar trasmesso in centrale Riavvicinando il magnete al rivelatore se il microswitch 3 in posizione ON sara trasmesso in centrale il segnale di fine allarme che annuller la condizione di allarme E previsto internamente un dipositivo antishock realizzato con un dispositivo piezoelettrico che in caso di urto violento genera un allarme che sar trasmesso in centrale Questa funzione escludibile con il microswitch 4 Il rivelatore AF913R permette inoltre di trasmettere in centrale lo stato di un contatto NA o NC collegato esternamente Collegando quindi opportunamente come indicato in fig 4 il contatto di uscita di un qualsiasi tipo di rivelatore riv temperatura riv acqua riv inerziale per tapparelle ecc la centrale potr riceverne il relati vo segnale di allarme microswitch 1 e 2 contaimpulsi pulse count permettono di determinare solo per l ingresso N C il numero di allarmi locali dopo i quali l allarme trasmesso in centrale Nota L ingresso NC deve essere abilitato rimuovendo il ponticello JP2 Se l ingresso NC non utilizzato JP2 deve restare inserito E possibile utilizzare contemporaneamente l ingresso NC ed il magnete al fine di controllare simultaneamente sia l apertura di una finestra sia il movimento della relativa tap
38. must be installed to protect all doors and windows In this case the magnet must be installed on the door or window to protect while the detector must be installed on the frame When the door is closed as indicated in fig 4 the distance between the detector and the magnet must not exceed 5 mm By increasing the distance between the magnet and the detector the REED relay opens its contact and produces the alarm that will be transmitted to the control panel By reducing the distance between the magnet and the detector the signal of end of alarm which interrupts the alarm will be transmitted to the control panel provided that the micro switch 3 is in ON position An internal anti shock device is provided it consists of a piezoelectric device that in the case of a violent shock produces an alarm that is transmitted to the control panel This function can be cancelled by means of the micro switch 4 By the AF913R detector the state of an externally connected NO or NC contact can be transmitted to the control panel Therefore if the output contact of a detector of any kind temperature detector water detector inertial detector for roller shutters etc is properly connected the control panel can receive the corresponding alarm signal By the micro switches 1 and 2 pulse count the number of local alarms can be calculated only for the N C input and then transmitted to the control panel Note NC imput has to be enabled by removing Jumper
39. nitamente ad un beep continuo di circa 15 s Al termine del tempo d uscita NON si avr l emissione di una segnalazione d allarme DESCRIZIONE FRONTALE E SEGNALAZIONI Fig 1 Tasto Reset Chiave meccanica y JP1 AF909RS ave La tabella illustra il significato delle segnalazioni ottiche ai quattro possibili stati riportate sulla centrale LED LAMPEGGIANTE Funzione Colore ACCESO SPENTO ad imp disinserito Stato di programmaz Stato operativo di PROG Giallo e o prova normale funzionamento TXON Rosso Trasmissione in corso Trasmissione non in corso SCANNER Rosso Allarme scanner Non in allarme o escluso Tamper Rosso Tamper aperto Tamper chiuso Zona Rosso Zona A1 in allarme Zona A1 esclusa 0 non i larme memorizzato Zona A2 Rosso Zona A2 in allarme Zona A2 esclusa o non i larme memorizzato Zona A3 Rosso Zona A3 in allarme Zona A3 esclusa o non i larme memorizzato Zona B4 Rosso Zona B4 in allarme Zona B4 esclusa o non i larme memorizzato Zona B5 Rosso Zona BS in allarme Zona B5 esclusa 0 non i larme memorizzato Zona B6 Rosso Zona B6 in allarme Zona B6 esclusa o non i larme memorizzato Zona C7 Rosso Zona C7 in allarme Zona C7 esclusa 0 non i larme memorizzato Zona C8 Zona C8 in allarme Zona C8 esclusa o non i larme memorizzato Zona C9 Zona C9 in allarme Zona C9 esclusa 0 non i larme memorizzato PANIC Allarme panico linea 24h Non in allarme larme memorizzato TEC ALARM Allarme tecnico linea
40. nte inserita NOTA la centrale trasmette il segnale di disinserito ad ogni commutazione della chiave meccanica oppure in occasione di un disinserimento tramite telecomando 3 Ricevendo dalla centrale il segnale di disinserito la sirena apprende automaticamente il codice che individua la centrale e lo memorizza indicando l evento con una segnalazione ottica ed una acustica a bassa intensit E quindi pronta per il normale funzionamento Nel caso venga sostituita la batteria interna o la centrale dell impianto sar necessario ripetere la proce dura di apprendimento del codice sopra vista Descrizione funzionamento segnali provenienti dalla centrale attivano le seguenti funzioni sulla sirena SEGNALE DALLA CENTRALE FUNZIONI ESEGUITE DALLA SIRENA INSERITO centrale inserita ON N 4 beep lampeggio DISINSERITO Centrale disinserita OFF N 1 beep lampeggio ALLARME Lampeggio con segnale acustico a bassa intensit per 10 s Successivamente lampeggio con segnale acustico ad alta intensit 115 db a 1m per 3 minuti Nota possibile regolare il volume della segnalazione acustica a bassa intensit tramite un potenzio metro situato sulla scheda elettronica Allarme manomissione Il contenitore prevede due contatti per l autoprotezione Uno contro l apertura e uno contro l asportazione Il segnale di allarme manomissione non viene trasmesso in centrale dalla sire na Predisposizione contatto antiaspo
41. opertu ra Successivamente il rivelatore pronto per il normale funzionamento Descrizione funzionamento Dopo 3 minuti dal collegamento della pila il rivelatore pronto a funzionare Rilevato un movimento d luogo a una trasmissione dall allarme Per ridurre il consumo della pila dopo l allame si hanno 2 minuti di blocco Nota In condizioni di riposo il LED sempre spento si accende solo quando il rivelatore in stato di allarme oppure in condizioni di test Test Per effettuare la prova copertura necessario porre il rivelatore in condizione di test A detta funzione si accede premendo con un cacciavite il pulsante di test posto nella parte inferiore del l involucro del rivelatore stesso e si rimane per 2 minuti si attiva il led di visualizzazione allarmi e si esclude la funzione di blocco rivelatore per 2 minuti a seguito allarme L ingresso alla funzione di test segnalato dal rivelatore tramite un beep Regolare a questo punto la sensibilit al minimo necessario agendo sul trimmer posizionato sulla scheda elettronica in alto a sinistra e in caso di ambienti disturbati spostare il ponticello conteggio impulsi in posizione 3 allarme dopo tre passi circa Allarme manomissione In qualunque momento aprendo il contenitore dell apparecchio si ha la trasmissione dell allarme mano missione Allarme per pila scarica La necessit di sostituzione della pila segnalata da 3 beep emessi dal rivelato
42. oria delle apparecchiature radio individuate dall or ganismo notificato prescelto N organismo notificato prescelto 0682 Luso del prodotto sul territorio italiano soggetto alle regolamentazioni del codice postale e delle tele comunicazioni n 615 art 334 e successivi Programmazione Per memorizzare nella centrale il codice del rivelatore volumetrico procedere come segue 1 porre la chiave meccanica in programmazione si accender il LED PROG 2 aprire il contenitore della centrale saranno emessi 3 beep di conferma ed acceso il LED della ZONA Acanale 1 3 premere il pulsante VERDE di un telecomando AF939R gi memorizzato si verifica l accensione in sequenza di tutti i LED di linea cio linea 1 2 3 4 5 6 7 8 9 PANIC TEC ALARM Ogni LED resta acceso finch non si preme nuovamente il tasto verde 4 fornire alimentazione al rivelatore tramite l apposita pila mentre il LED del canale desiderato acceso Alla prima alimentazione ogni rivelatore trasmette il proprio codice per 30 s questo permette alla cen trale di memorizzare il codice del rivelatore nella propria memoria ed abbinarlo al canale selezionato 5 la centrale conferma l avvenuta memorizzazione del codice del rivelatore con un beep di conferma seguito da N 5 beep brevi La sequenza pu essere interrotta premendo il pulsante TAMPER del rive latore 6 A questo punto il rivelatore si pone in condizione di test per 2 minuti per permettere la prova c
43. ostale e delle tele comunicazioni n 615 art 334 e successivi DESCRIZIONE DEL FUNZIONAMENTO Inserimento disinserimento parzializzazione Le operazioni di inserimento disinserimento e parzializzazione dell impianto possono essere effettuate come di seguito descritte tramite il telecomando solo quando la chiave meccanica in posizione ON La chiave in posizione PROG porta il sistema in condizione di programmazione e TEST Premere il pulsante ROSSO del telecomando si ha l accensione di tutti i led INSERIMENTO di Zona A B C e l emissione di 3 beep di conferma i LED si spengono TOTALE allo scadere del tempo di uscita fisso a 60 secondi AI termine del tempo di uscita tutti i LED rimangono spenti Premere il pulsante VERDE del telecomando prima di entrare nell area pro tetta si ha un lungo beep di conferma i led dei canali che hanno memo rizzato allarmi lampeggiano alcuni dispositivi d allarme ripetono le segna lazioni ottico acustiche tipiche delle manovre ON OFF DISINSERIMENTO possibile inserire le Zone A B C singolarmente come segue 1 premere contemporaneamente i pulsanti ROSSO e VERDE del telecoman do lampeggiano in sequenza i LED di zona A canalet 2 e 3 zona B INSERIMENTO canali 4 5 e 6 e zona C canali 7 8 69 PARZIALE 2 per escludere la zona desiderata premere il pulsante VERDE oppure quello ROSSO durante il lampeggio del LED relativo AI termine della sequenza si ha
44. parella l allarme sar generato o dall apertu ra della finestra o dal movimento della fapparella ow La trasmissione di uno stato d allarme visualizzata dal LED sul corpo del rivelatore La tabella di seguito riportata illustra le possibilit di utilizzo del rivelatore AF913R e la relativa predispo zione IMPIEGO PREDISPOSIZIONE Fissare il magnete in dotazione sulla porta o finestra da proteggere ed il rivelatore AF913R sull infisso Selezionare se desiderata la funzione di fine allarme tramite il microswitch 3 ON fine allarme abilitato Protezione OFF fine allarme disabilitato porte e finestre Pu essere inserita tramite il microswitch 4 la protezione antishock ON antishock abilitato OFF antishock disabilitato Regolare infine il contaimpulsi pulse count come indicato in fig 4 per ottenere un allarme antishock dopo il numero di impulsi desiderato Protezione tapparelle Abilitare l ingresso NC rimuovendo JP2 Collegare all ingresso NC della muri collegamento morsettiera del riv AF913R il contatto d uscita NC di un rivelatore inerzia esterno di rivelatori le a vibrazione o di un rivelatore a fune per protezione tapparelle Regolare inerziali o il contaimpulsi pulse count come indicato in fig 4 per ottenere un allar rivelatori a fune me dopo il numero di impulsi desiderato Allarmi Tecnici Collegare alla morsettiera il contatto d uscita di un rivelatore per allarme collegamento esterno di
45. qua etc allarme tamper tentativi di manomissione dellla centrale stessa di suoi componenti E completa di batterie al litio non ricaricabili Incorpora una sirena a due livelli di intensit sonora elevata potenza per segnalazioni di allarme intrusio ne o panico bassa intensit per segnalazioni di conferma alle manovre dell utente E realizzata in un contenitore da parete in materiale plastico CARATTERISTICHE TECNICHE e Alimentazione 7 2Vcc fornita da batteria al litio 2x Litium Size da 3 6V 7 2V 13Ah cod AVE AF915 e 9 canali 3 zone cos suddivise e 3 zone cos suddivise Zona A formata dai canali 1 2 3 Zona B formata dai canali 4 5 6 Zona C formata dai canali 7 8 9 Tempo d ingresso riferito alla zona A canale 1 pari a 30 secondi Canale di tipo 24h per allarme panico radio Canale di tipo 24h per allarme tecnico radio Canale di tipo 24h per allarme tamper radio Inserzione parzializzazione disinserzione dell impianto tramite telecomando AF939R Attivazione allarme panico tramite telecomando AF938R Numero massimo di codici distinti di telecomandi o rivelatori radio memorizzabili 64 Chiave meccanica incorporata Sirena interna a due livelli di intensit sonora per segnalazione allarme e conferma manovre Assorbimento a riposo da batteria 100uA max Assorbimento in allarme da batteria 200mA max Autonomia batteria oltre 3 anni con 10 cicli di allarme anno e 4 manovre ON OFF al giorno Antenna a filo incorporata nel con
46. re congiuntamente alla pesi 12 segnalazione di allarme oltre un mese prima della scarica totale AF913R E AF913R M RIVELATORE PERIMETRALE MULTIFUNZIONE Fig 4 Buzzer di segnalazione pila scarica H 5 mm mox JP2 Ponticello per abilitazione ingresso NC Inserito ingresso NC escluso Disinserito ingresso NC abilitato Contatto rivelatore esterno via filo Ly JP1 Ponticello per esclusione allarme rimozione al Inserito allarme rimozione escluso Disinserito allarme rimozione abilitato 12 12 12 12 4 SHOCK e B i Gi 8 FINE 1 2 4 8 Ei ALLOGGIAMENTO ALLARME conteggio impulsi PILA Sostituzione della batteria a togliere l elastico di chiusu b rimuovere la batteria e sosti c richiudere con l apposito ra tuirla facendo attenzione alle elastico polarit Caratteristiche tecniche e Alimentazione pila alcalina 9V standarad size 6LR16 oppure pila al litio SAFT 9V e Assorbimento 18 in stand by 20 mA in trasmissione e Autonomia con pila alcalina 18 mesi con pila litio 30 36 mesi k e Funzioni operative segnalazione di apertura porta segnalazione di chiusura porta allarme shock tentato scasso allarme con contaimpulsi per collegamento esterno di rivelatori inerziali allarme tecnico per collegamento esterno di rivelatori t
47. rotection against reversal of battery by means of a polarised connector Polycarbonate cover and bottom Protection degree IP34 Metal auxiliary antifoaming cap for horn protection Temperature 20 C 55 C Relative humidity at 35 C 95 max Reference standards AF53901R complies with the basic requirements of the 99 05 CE Directive Technical Standards EN60950 1996 along with their further amendments ETS300683 1997 EN300220 1 were applied e e o 332 Programming 1 Connect the lithium battery by means of the corresponding connector The siren enters the quiescent state waiting for the radio code linking it to the radio control panel of the system 2 Transmit the signal of disconnected from the control panel control panel disconnected OFF by turning the mechanical key or by disconnecting the previously connected control panel by means of the remote control NOTE Each time the mechanical key is turned or every time a disconnection is carried out by means of the remote control the control panel transmits the signal of disconnected 3 Once the siren has received the signal disconnected from the control panel it learns and stores automatically the code linking it to the control panel and produces an optical as well as a high inten sity acoustic signal It is now ready to operate If the internal battery or the system control panel are replaced the code learning procedure needs to be repeated Op
48. rs number of pulses Technical alarms exter nal connection of detec tors for technical alarms Connect the output contact of a detector for technical alarms to the terminal board We suggest using the NO input which cuts out the pulse count automatically Open the detector by levering on the fastening ring by means of a screwdriver If the intrusion protection is used fasten the detector body on the wall or the frame by means of screws Use silicone and not the adhesive tape if it is installed on glass Programming The sequence of programming is the same as for the AF968R volumetric detectors illustrated at page 28 The micro switch 3 must be programmed before carrying out the programming sequence of the detector If the function of the micro switch 3 is changed the programming sequence of the detector must be repeated Programming of micro switches 1 2 and 4 can be changed without repeating programming Note in order to use the multi function door window detector to connect a detector for technical alarms to the control panel by radio the detector must be programmed on the channel TECH ALARM Tampering alarm At any moment by opening the enclosure the tampering alarm is transmitted by the corresponding micro switch By means of a second micro switch placed on the back of the card the detector transmits also the removal alarm The removal alarm can be connected or disconnected by means of the JP1 jumper see fig 4 Alarm
49. rtazione Per realizzare la protezione antiasportazione necessario mantenere chiuso il contatto antiasportazione posto sul retro della sirena applicando al muro una vite nella posizione indicata dalla dima di foratura sporgente di 10 mm che andr a premere il pistoncino color ottone e quindi chiudere il contatto come mostrato in figura 19 Allarme per batteria scarica La necessit della sostituzione della batteria segnalata con una serie di beep della durata di 30s emes sa all atto dell inserimento e del disinserimento del sistema Nota tutte le operazioni di manutenzione devono essere effettuate scollegando la batteria in modo da lasciare la lampada allo Xenon senza alimentazione Kom 20 SCHEMA APPLICATIVO ALL APPARECCHIO TELEFON ICO ALLA PRESA TELEFONICA RIV IRP RADIO gt AF968R o gt _ P1 gt COMBINATO RE TAFTONICO sos ARAOR _eP RIVELATO RI PERIMETRALE MULTIFUN ZIONE AF913R p SIREN A AUTO ALIM EN TATA AF53901R N S TELECOMAN DO AF939R IN SERZIO N E DISIN SERZIO N E PARZIAUZZAZIO N E W ireless burglar alarm contro panel SUPERVISED cop AF909RS 21 Contents INTFOAUCHON i i Lette pag 21 Technical dat eri pag 21 Climatic condition
50. sione se la centrale si trova nello stato di inserito se la centrale si trova nello stato di disin serito la sequenza d allarme differisce nel fatto che non viene attivata la sirena AF53901R collegata via radio alla centrale L allarme tamper proveniente da un riv radio visualizzato in centrale dal LED tamper e dal LED del canale interessato NOTA prima di procedere al cambio delle batterie dei rivelatori radio sar opportuno predisporre la chiave meccanica in PROGRAMMAZIONE per evitare segnalazioni ottico acustiche di manomissione Condizione di allarme 24h Programmando opportunamente rivelatori perimetrali multifunzione e o telecomandi si possono avere i seguenti allarmi indipendenti dallo stato di inserito o disinserito della centrale vedi tabella seguente Attiva e lasirena interna segnalazione acustica ad alta intensit per 15 s PANICO e la sirena AF53901R collegata via radio alla centrale ad impianto attivo e eventuale combinatore telefonico radio AF53902R ALLARME TECNICO Attiva la sirena interna segnalazione acustica a bassa intensit Condizione di allarme scanner La centrale provvista di un particolare circuito in grado di rilevare un tentativo di manomissione effet tuato tramite uno scanner Il circuito segnala un allarme quando intercetta un tentativo di ricostruzione del codice normalmente inviato da telecomando oppure quando trasmessa una portante fissa La condizione di
51. sivamente tale funzione ripetere la sequenza Allo spegnimento del LED tamper la fun zione di supervisione disinserita Segnalazione di batteria centrale scarica Lo stato di batteria che richiede intervento e o sostituzione segnalato dalla centrale oltre un mese prima della scarica totale nel modo seguente oy s Stato centrale Sirena interna alla centrale LED di zona Inserita Segnalazione ad alta intensit per 15 s Disinserita Tutti i LED Segnalazione intermittente All atto dell inserimento a bassa intensit lampeggianti per 15 s All atto del disinserimento per 15s Tutti i LED lampeggianti per 30 s Segnalazione batteria rivelatori AF913R AF913R M e AF968R scarica Lo stato di carica della batteria dei rivelatori segnalata dalla centrale all atto dell inserimento o del disinserimento della centrale stessa nel seguente modo e LED di zona lampeggiante e Segnalazione acustica intermittente per 15 s a bassa intensit A centrale disinserita solo con il LED di zona Segnalazione di porta aperta non pronto all inserimento Nel caso in cui un rivelatore perimetrale opportunamente programmato tramite il microswitch 3 per tra smettere la segnalazione di porta rimasta aperta vedi pag 13 14 rilevi la condizione di porta aperta all atto dell attivazione dell impianto in centrale si avr la seguente segnalazione lampeggio durante il tempo di uscita del LED relativo al canale interessato u
52. specific products for special environments e In the case of products powered by batteries should they be discharged they must be replaced with similar batteries and disposed according to the rules in force In the case of liquid leaks replace them immediately clean the battery housing with care wearing silicone gloves In the case of liquid contact wash your hands carefully e In the case of products powered with lithium batteries in addition to the above precautions remember that they must be replaced by skilled personnel as they present explosion hazard INTRODUCTION AF909RS is a 9 zone wireless burglar alarm control unit allowing radio connection of intrusion detec tors It is also equipped with 3 24h type channels used for panic technical gas smoke water etc tampering tampering attempts on the control unit or its components It is provided with non rechargeable lithium batteries It is equipped with a built in high power buzzer to send panic and intrusion alarms and low intensity to confirm user operations It is contained into a plastic wall enclosure TECHNICAL DATA e Power supply 7 2 Vdc supplied with 2X Lithium Size battery 3 6 V 7 2 V 13 Ah code AVE AF915 e 9 channels 3 zones subdivided as follows Zone A composed of channels 1 2 3 Zone B composed of channels 4 5 6 Zone C composed of channels 7 8 9 Entry time referred to zone 1 equal to 30 seconds 24h type channel for panic radio alarms
53. t Apertura contenitore Caratteristiche tecniche e Alimentazione pila alcalina 9V standarad size 6LR16 oppure pila al litio SAFT 9V e Assorbimento 18 in stand by 20 mA in trasmissione e Autonomia con pila alcalina 18 mesi con pila al litio 30 36 mesi e Posizionamento fissaggio a parete meglio ad angolo ad una altezza di 2 2 30 m e Area protetta apertura 100 per 12m di portata 20 fasci sensibili su 3 piani e Sensibilit regolabile con trimmer dal 30 al 100 e Rivelaz allarme programmabile a conteggio impulsi 1 3 selezionabile tramite ponticello pulse count Test visualizzazione della rivelazione del movimento tramite LED Compensazione automatica in temperatura Invio segnale di presenza supervisione e di batteria scarica ogni 72 minuti Caratteristiche R F trasmissione quarzata a 433 92 MHZ potenza max 10mW Codifica segnali codice random 86 bit preimpostato Oltre 68 miliardi di combinazioni e Portata utile pi di 40 m in aria libera Circa 30 m in ambienti residenziali e Dimensioni 132x65x46 mm e Installazione per sicurezza installare in posizione non normalmente accessibile dall utente Riferimenti normativi Il rivelatore AF968R conforme ai requisiti essenziali fissati dalla direttiva 99 05 CE e ad esso sono state 11 per applicate le Norme tecniche EN60950 1996 e successive varianti ETS600683 1997 EN300220 1 e la serie di prove radio essenziali e specifiche della categ
54. tenitore Batteria al litio in dotazione collegabile alla scheda tramite conduttori flessibili provvisti di connettore polarizzato Protezione contro l inversione di polarit della batteria con connettore polarizzato Classificazione della parte radio Frequenza della portante 433 92 MHz Potenza massima del trasmettitore 10 mW Portata nominale del collegamento 30 metri in condizioni normali nell ambiente abitativo pareti metalliche o strutture antisismiche possono ridurre la portata Evitare l installazione di AF909RS e dei rivelatori radio a meno di 2 cm da pareti metalliche Condizioni climatiche requisiti e le prestazioni della centrale secondo norme CEI 79 2 vengono garantiti secondo le seguenti condizioni climatiche e Temperatura e umidit relativa di riferimento 25 C U R 65 e Campo temperatura ambiente di funzionamento da 10 C a 50 C na e Umidit relativa massima 90 a 35 C Altitudine 2000m s l m Riferimenti normativi La centrale AF909RS conforme ai requisiti essenziali fissati dalla direttiva 99 05 CE e ad essa sono state applicate le Norme tecniche EN60950 1996 e successive varianti ETS300 683 1997 EN300220 1 1997 e la serie di prove radio essenziali e specifiche della categoria delle apparecchiature radio indivi duate dall organismo notificato prescelto N identificazione organismo notificato 0682 Luso del prodotto sul territorio italiano soggetto alle regolamentazioni del codice p
55. trol panel automatically turns to the TEST state If it receives an alarm signal transmitted by radio it produces a beep for confirmation and the channel of the corresponding LED switches ON If a detector is tampered with the LED of the corresponding channel and that of the tampering LED turn on simultaneously while a beep is produced Alarm due to intrusion If the control panel is connected the intrusion alarm signal from the radio detectors starts the following alarm sequence e The AF53901R self powered radio siren switches on e The buzzer housed inside the control panel switches on and produces a high intensity acoustic signal e The AF53902R radio telephone dialler if any switches on The alarm sequence lasts 2 minutes and is repeated if a new signal comes from the detectors Each channel is automatically disconnected after 3 consecutive alarms The zone where the alarm has been started is stored but it will be displayed only when disconnecting the system When switching to the disconnected state the present alarm is immediately interrupted The alarm sequence described above concerns the 9 channels and you should consider that e Channel 1 from ZONA A is delayed by 30 seconds entry time e When channel 1 from ZONE A first receives the alarm the entry time is extended to channels 2 3 4 5 6 7 8 9 These channels are considered input path channels Alarm due to tampering The tamper alarm signal can be transm
56. trusione proveniente dai rivelatori radio provoca la seguente sequenza d allarme e Attivazione della sirena radio autoalimentata AF53901R e Attivazione della sirena interna alla centrale La stessa genera una segnalazione acustica ad alta inten sit e Attivazione dell eventuale combinatore telefonico radio AF53902R La sequenza d allarme dura 2 minuti e si ripete in caso di nuova segnalazione proveniente dai rivelatori Ogni canale si autoesclude dopo essere stato interessato a 3 allarmi consecutivi La zona interessata all allarme provoca una memorizzazione che verr resa visibile solo all atto della disinserzione dell impianto La commutazione in disinserito provoca anche l interruzione immediata dell allarme in corso La sequenza d allarme cos descritta vale per i 9 canali tenendo conto che e Il canale 1 della ZONA A ritardato di 30 sec tempo di ingresso e Qualora il canale 1 della ZONA A riceva per primo un allarme il ritardo d ingresso di 30 sec si estende anche ai canali 2 3 4 5 6 7 8 9 Detti canali si intendono a percorso d ingresso Condizione di allarme per manomissione Tamper Il segnale di allarme manomissione pu provenire via radio dai relativi rivelatori ogni rivelatore via radio trasmette in caso di manomissione del proprio involucro il segnale di manomissione In caso di manomissione della centrale e o dei rivelatori la sequenza d allarme uguale a quella dell al larme intru