1. SN4 ST1 Temperature sensor selection With INP SN4 the probes must be the LAE models SN4 with INP ST1 the probes must be the LAE models ST1 co 12 5 12 5 C Probe T1 offset NO YES Probe T2 enabling evaporator 082 12 5 12 5 C Probe T2 offset Delay for minimum temperature TLO and maximum temperature THI logging m E Display slowdown Kj 1255 AT1 5 address for PC communication WIRING DIAGRAM door switch T2 Com T1 gt AUX 16 5 A 7 2 A T2 Com T1 a AUX 16 8 A 7 2 A 230Vac 230Vac AT1 5BS4E AG AT1 5BS6E BG 230Vac AT1 5AS6E BG TECHNICAL DATA Power supply 5 E 230Vac 10 50 60Hz 3W AT1 5 U 115Vac 10 50 60Hz 3W AT1 5 D 12Vac 10 50 60Hz 3W Relay outputs AT1 5 01 2 compressor 12 4 A AT1 5 1 2 compressor 16 4 A AT1 5 03 4 compressor 12 5 A AT1 5 3 4 compressor 16 5 A AT1 5 05 6 compressor 12 8 A AT1 5 5 6 compressor 16 8 A Auxiliary loads 7 2 A 240vac AT1 5 0 maximum total current 12A AT1 5 S maximum total current 16A Inputs NTC 10KQ 25 C LAE part No SN4 PTC 10002 25 C LAEpartNo ST1 Measuring Range 50 120 C 55 240 F 50 9 9 19 9 80 C with NTC10K only Measuring accuracy lt 0 5 C within the measurement range Operating conditions 10 50 C 15 80 r H CE UL Approvals and Reference Norms EN60730 1 EN60730 2 9 EN55022 Class B EN50082 1 UL60730 1A Front
2. AT1 5 INSTRUCTIONS FOR USE ISTRUZIONI D USO PARTNER VENEZIA e 041 5460713 n m OLAT1002 05 12 12 2007 12 01 13
3. m Premere per almeno mezzo secondo il tasto per visualizzare il valore del setpoint m Mantenendo premuto agire con i tasti w o a per impostare il valore desiderato la regolazione compresa entro il limite minimo SPL e massimo SPH m Alrilascio del tasto il nuovo valore viene memorizzato STAND BY Il tasto O premuto per 3 secondi consente di commutare lo stato del regolatore fra operativit delle uscite e standby solo con SB YES BLOCCO DELLA TASTIERA Il blocco dei tasti impedisce operazioni indesiderate potenzialmente dannose che possono avvenire qualora il regolatore operi in ambiente pubblico Per inibire tutti i comandi da tastiera impostare LOC YES nel men INFO per ripristinare la normale funzionalit riprogrammare LOC NO SBRINAMENTO Sbrinamento temporizzato Uno sbrinamento viene attivato automaticamente quando il timer interno raggiunge il tempo necessario per ottenere la frequenza di sbrinamento DFR Ad esempio con DFR 4 si avranno 4 sbrinamenti in 24 ore ovvero uno ogni 6 ore Il timer interno azzerato all accensione dello strumento e ad ogni avvio di sbrinamento nel modo stand by il conteggio accumulato congelato Sbrinamento manuale possibile attivare uno sbrinamento manualmente premendo per 2 secondi il tasto BI Tipo di sbrinamento Iniziato uno sbrinamento le uscite Compressore e Sbrinamento sono comandate in conformit ai parametri DTY e OAU L uscita AUX collegata al
4. AT1 5 INSTRUCTIONS FOR USE Thank you for having chosen a LAE electronic product Before installing the instrument please read these instructions carefully to ensure maximum performance and safety DESCRIPTION INDICATIONS n I ON U Thermostat output Auxiliary output Alarm lr JER E MN x O Fig 1 Front panel lit Info Setpoint button Increase manual activation button Manual defrost Decrease button x Exit Stand by button A INSTALLATION m Insert the controller through a hole measuring 71x29 mm Make sure that electrical connections comply with the paragraph wiring diagrams To reduce the effects of electromagnetic disturbance keep the sensor and signal cables well separate from the power wires m Fix the controller to the panel by means of the suitable clips by pressingly gently if fitted check that the rubber gasket adheres to the panel perfectly in order to prevent debris and moisture infiltration to the back of the instrument m Place the probe T1 inside the room in a point that truly represents the temperature of the stored product m Place the probe T2 where there is the maximum formation of frost OPERATION DISPLAY During normal operation the display shows either the temperature measured or one of the following indications DEF Defrost in progress HI Room high temperature alarm REC Recovery after defrost LO Room low temperature alarm OFF Controlle
5. protection IP55 Cllae ELELTRONIL VIA PADOVA 25 31046 ODERZO TV ITALY TEL 39 0422 815320 FAX 39 0422 814073 www lae electronic com E mail sales lae electronic com 12 12 2007 12 01 10 PARTNER VENEZIA 041 5460713 AT1 5 ISTRUZIONI D USO Vi ringraziamo per la preferenza accordataci scegliendo un prodotto LAE electronic Prima di procedere all installazione dello strumento leggete attentamente il presente foglio d istruzioni solo cos potrete ottenere massime prestazioni e sicurezza DESCRIZIONE INDICAZIONI ax Uscita termostatazione RLZ Uscita ausiliaria A Allarme JER E NN I x NO Fig 1 Pannello frontale lit Tasto Info Setpoint Tasto sbrinamento manuale decremento INSTALLAZIONE m Inserire lo strumento in un foro di dimensioni 71x29 mm m Eseguire i collegamenti elettrici facendo riferimento al paragrafo schemi di collegamento Per ridurre gli effetti delle perturbazioni elettromagnetiche distanziare i cavi delle sonde e di segnale dai conduttori di potenza m Fissare lo strumento al pannello mediante le apposite staffette esercitando una corretta pressione qualora presente la guarnizione di gomma dev essere interposta fra la cornice dello strumento ed il pannello verificandone la perfetta adesione per evitare infiltrazioni verso la parte posteriore dello strumento m Posizionare la sonda T1 in un punto della cella che ben rappresenti la temperatura del prodot
6. A to set the desired value m When button i is released the newly programmed value is stored and the following parameter is displayed To exit from the setup press button X or wait for 30 seconds ISTR AT1 5 INGLESE ITALIANO indd1 1 PAR RANGE DESCRIPTION 126 2 ofp GJ sensa Di iii DI lic HYS OFF ON thermostat differential ON ve N Q OFF OFF T SP SP HY Readout scale 1 C only with INP SN4 measuring range 50 9 9 19 9 80 C 2 C measuring range 50 120 C F measuring range 55 240 F Caution upon changing the SCL value itis then absolutely necessary to reconfigure the parameters relevant to the absolute and relative temperatures SPL SPH SP ALA AHA etc SP HY SP T Refrigerating control C H REF Heating control C H HEA 0 30min Compressor rest time The output is switched on again after CRT minutes have elapsed since the previous switchover We recommend to set CRT 03 with HYS lt 2 0 Thermostat output run when probe T1 is faulty With CT1 0 the output will always remain OFF CT2 0 30min Thermostat output stop when probe T1 is faulty With CT2 0 and CT1 gt 0 the output will always be ON Example CT1 4 CT2 6 In case of probe T1 failure the compressor will cycle 4 minutes ON and 6 minutes OFF se I se ene DTY OFF Defrost type ERE OFF off cycle defrost Compressor and Heater OFF GAS ELE electric defrost Compressor OFF an
7. F OFF SP SP HY T SP HY SP T Controllo in refrigerazione C H REF Controllo in riscaldamento C H HEA 0 30min Tempo di fermata del compressore La riaccensione dell uscita avviene solo se sono trascorsi CRT minuti dal precedente spegnimento Consigliamo CRT 03 con HYS lt 2 0 0 30min Tempo di attivazione dell uscita termostato durante un anomalia della sonda T1 Con CT1 0 l uscita sar sempre OFF Tempo di fermata dell uscita termostato durante un anomalia della sonda T1 Con CT2 0 e CT1 gt 0 l uscita sar sempre ON Esempio CT1 4 CT2 6 In caso di rottura della sonda T1 il compressore funziona con cicli di 4 minuti ON e 6 minuti OFF rn aa lo i e OFF Tipo di sbrinamento BRE OFF sbrinamento a fermata Compressore e Sbrinatore OFF GAS ELE sbrinamento elettrico Compressore OFF e Sbrinatore ON GAS sbrinamento a gas caldo Compressore e Sbrinatore ON l uscita sbrinamento viene attivata se OAU DEF DTY DDY Display in sbrinamento Se DDY 0 durante uno sbrinamento continua ad essere visualizzata la temperatura Se DDY gt 0 durante uno sbrinamento il display visualizza DEF e al termine dello sbrinamento visualizza REC per DDY minuti ATM Gestione soglie allarme NON Tutti gli allarmi di temperatura sono interdetti Il successivo parametro sar ADO ABS valori programmati in ALA e AHA rappresentano le reali soglie d allarme REL 1 valori programmati in ALR e AH
8. R sono i differenziali d allarme rispetto a SP e SP HY ON ON OFF TI OFF Tl SP ALR SP SP HYS AHR SP HYS ALR SP SP AHR Allarme di temperatura con soglie relative Allarme di temperatura con soglie relative in refrigerazione ATM REL C H REF in riscaldamento ATM REL C H HEA ATD 0 120min Ritardo nella segnalazione dell allarme di temperatura Ritardo nella segnalazione dell allarme di porta aperta 0 52 Pulizia periodica condensatore Quando il tempo di funzionamento del compressore espresso in settimane settimane raggiunge il valore ACC sul display lampeggia CL Con ACC 0 l indicazione per la pulizia del condensatore disabilitata NO YES Abilitazione tasto standby O NO YES Abilitazione sensore ingresso porta chiuso con porta chiusa Funzionamento dell uscita ausiliaria AUX NON uscita disabilitata 0 1 icontatti del rel seguono lo stato on standby del regolatore DEF uscita programmata per il comando dello sbrinamento LGT uscita abilitata al controllo delle luci ALR chiusura dei contatti al presentarsi di una condizione d allarme SN4 ST1 Selezione del sensore di temperatura Con INP SN4 le sonde devono corrispondere ai modelli LAE SN4 con INP ST1 devono corrispondere ai modelli LAE ST1 co 12 5 12 5 C Correzione misura sonda T1 NO YES Abilitazione della sonda T2 evaporatore 0S2 12 5 12 5 C Correzione misura sonda T2 Ritardo nella memorizzazione delle tem
9. d Heater ON GAS hot gas defrost Compressor and Heater ON The defrost output is active if only OAU DEF DDY Display during defrost If DDY 0 during defrost the temperature continues to be displayed If DDY gt 0 during defrost the display shows DEF when defrost is over REC is displayed during DDY minutes ATM NON Alarm threshold management ABS NON all temperature alarms are inhibited the following parameter will be ADO REL ABS the values programmed in ALA and AHA represent the real alarm thresholds REL the values programmed in ALR and AHR are alarm differentials referred to SP and SP HY ON ON OFF TP OFF TP SP ALR SP SP HYS AHR SP HYS AI R SP SP AHR Temperature alarm with relative thresholds Temperature alarm with relative thresholds refrigerating control ATM REL C H REF heating control ATM REL C H HEA O Ua Condenser periodic cleaning When the compressor operation time expressed in weeks matches the ACC value weeks programmed CL flashes in the display With ACC 0 the condenser cleaning warning is disabled NO YES Stand by button enabling K NO YES Door switch input enabling closed when door is closed AUX output operation 0 1 NON output disabled always off DEF 0 1 the relay contacts follow the on standby state of controller LGT DEF output programmed for defrost control ALR LGT output enabled for light control ALR contacts make when an alarm condition occurs
10. eter LOC YES to inhibit all functions of the buttons To resume normal operation of keypad adjust setting so that LOC NO DEFROST Timed defrost Defrosting starts automatically when necessary time has elapsed to obtain the defrosting frequency set with DFR For example with DFR 4 defrosting occurs once every 6 hours The internal timer is set to zero when power is applied to the controller and at each subsequent defrost start When the controller is put on a standby the accumulated time count is frozen is not incremented Manual defrost Defrosting may also be induced manually by keeping the button pressed for 2 seconds Defrost type Once defrost has started Compressor and Defrost outputs are controlled according to the parameters DTY and OAU The AUX output is associated to defrost function with OAU DEF exclusively Defrost termination Defrost lasts as long as time DTO but if the evaporator probe has been enabled T2 YES and temperature DLI is achieved before this time elapses defrost will be terminated in advance Caution if C H HEA all defrost functions are inhibited if DFR 0 the timed defrost function is excluded during defrost the high temperature alarm is inhibited CONFIGURATION PARAMETERS m The setup menu is accessed by pressing button XkLi for 5 seconds With button w or a select the parameter to be modified m Press button Li to display the value m By keeping button i pressed use button or
11. la funzione di sbrinamento solo con OAU DEF Termine dello sbrinamento Lo sbrinamento ha una durata pari al tempo DTO ma qualora la sonda di evaporatore sia attivata T2 YES ed entro tale tempo raggiunga la temperatura DLI lo sbrinamento avr una conclusione anticipata Attenzione se C H HEA tutte le funzioni di sbrinamento sono inibite se DFR 0 viene esclusa la sola funzione di sbrinamento temporizzato durante uno sbrinamento l allarme d alta temperatura interdetto PARAMETRI DI CONFIGURAZIONE Per accedere al men di configurazione dei parametri premere per 5 secondi i tasti K G Con i tasti Y o a selezionare il parametro da modificare Premere il tasto i per visualizzare il valore Mantenendo premuto i agire con i tasti w o A per impostare il valore desiderato AI rilascio del tasto i il nuovo valore viene memorizzato e viene visualizzato il parametro successivo Per uscire dal setup premere il tasto X o attendere 30 secondi ISTR AT1 5 INGLESE ITALIANO indd2 2 PAR RANGE DESCRIZIONE Pe scala di lettura Zali 1 C solo con INP SN4 range di misura 50 9 9 19 9 80 C F 2 C range di misura 50 120 C F rangedimisura 55 240 F Attenzione cambiando il valore di SCL vanno assolutamente riconfigurati parametri riguardanti le temperature assolute e relative SPL SPH SP ALA AHA ecc fl cil SS Ld betas n Differenziale OFF ON del termostato HYS ON o ON Lea OF
12. perature minime TLO e massime THI raggiunte m IE Rallentamento display a 255 Indirizzo di AT1 5 per la comunicazione con PC SCHEMI DI COLLEGAMENTO interr interr porta FP porta T2 Com T1 ak AUX 16 5 A 7 2 A T2 Com T1 gt AUX 16 8 A 7 2 A 230Vac 230Vac AT1 5BS4E AG interr porta AUX 16 8 A 7 2 A 230Vac AT1 5AS6E BG ELECTRONIC INSTRUCTIONS FOR USE ISTRUZIONI D USO VIA PADOVA 25 31046 ODERZO TV ITALY TEL 39 0422 815320 FAX 39 0422 814073 www lae electronic com E mail sales lae electronic com DATI TECNICI Alimentazione AT1 5 E 230Vac 10 50 60Hz 3W AT1 5 U 115Vac 10 50 60Hz 3W AT1 5 D 12Vac 10 50 60Hz 3W Uscite rele AT1 5 01 2 compressore 12 4 A AT1 5 1 2 compressore 16 4 A AT1 5 03 4 compressore 12 5 A AT1 5 3 4 compressore 16 5 A AT1 5 05 6 compressore 12 8 A AT1 5 5 6 compressore 16 8 A Carichi ausiliari 7 2 A 240vac AT1 5 0 massima corrente complessiva 12A AT1 5 S massima corrente complessiva 16A Ingressi NTC 10KQ 25 C codice LAE SNA PTC 100002 25 C codice LAE ST1 Range di misura 50 120 C 55 240 F 50 9 9 19 9 80 C solo NTC10K Precisione di misura lt 0 5 C nel range di misura Temperatura di funzionamento 10 50 C CE UL Approvazioni e Normative di riferimento EN60730 1 EN60730 2 9 EN55022 Classe B EN50082 1 UL60730 1A Protezione frontale IP55
13. r in stand by E1 Probe T1 failure CL Condenser clean warning E2 Probe T2 failure DO Door open alarm INFO MENU The information available in this menu is T1 Instant probe 1 temperature TLO Minimum probe 1 temperature recorded T2 Instant probe 2 temperature CND Compressor working weeks THI Maximum probe 1 temperature recorded LOC Keypad state lock Access to menu and information displayed m Press and immediately release button Li m With button or A select the data to be displayed Press button i to display value To exit from the menu press button X or wait for 10 seconds Reset of THI TLO CND recordings With button Y or A select the data to be reset Display the value with button Li m While keeping button i pressed use button K SETPOINT display and modification of desired temperature value Press button for at least half second to display the setpoint value m By keeping button pressed use button or A to set the desired value adjustment is within the minimum SPL and the maximum SPH limit m When button is released the new value is stored STAND BY Button O when pressed for 3 seconds allows the controller to be put on a standby or output control to be resumed with SB YES only KEYPAD LOCK The keypad lock avoids undesired potentially dangerous operations which might be attempted when the controllers is operating in a public place In the INFO menu set param
14. to da conservare m Posizionare la sonda T2 temperatura dell evaporatore nel punto di maggior formazione di brina FUNZIONAMENTO am Tasto incremento modalit manuale Tasto uscita Stand by VISUALIZZAZIONI In funzionamento normale sul display viene visualizzata la temperatura rilevata oppure una delle indicazioni seguenti DEF sbrinamento in corso HI allarme di alta temperatura in cella REC ristabilimento dopo uno sbrinamento LO allarme di bassa temperatura in cella OFF strumento in stand by E1 guasto nella sonda T1 CL richiesta pulizia condensatore E2 guasto nella sonda T2 DO allarme porta aperta MENU INFO Le informazioni disponibili nel men info sono T1 temperatura istantanea sonda 1 TLO T2 temperatura istantanea sonda 2 CND THI temp massima registrata sonda 1 LOC temperatura minima registrata sonda 1 settimane di funzionamento del compressore stato della tastiera blocco Accesso al men e visualizzazione informazioni m Premere e subito rilasciare iltasto Lil m Conitasti Y 0 a selezionare il dato da visualizzare m Premere il tasto i per visualizzare il valore m Per uscire dal men premere il tasto X o attendere 10 secondi Reset delle memorizzazioni THI TLO CND m Conitasti Y o 4 selezionare il dato da resettare m Visualizzare il valore con il tasto Lil m Mantenendo premuto il tasto i premere il tasto KX SETPOINT visualizzazione e modifica valore di temperatura desiderato

Download Pdf Manuals

image

Related Search

Related Contents

Manual del Usuario  Lenoxx PH-3235 User's Manual  StarTech.com 24in Internal 2 pin IDC Motherboard Header Cable - HDD LED Cable F/F  About Your Appliance: NetBotz 320  High Density Analog I/O Modules User Manual, 1756-UM540C-EN-P  Dvr4mqa GB-NL-FR-ES-D  USER MANUAL DVR Camera    User Manual  FISCAL OFFICER TRAINING MANUAL  