SIMATIC NET

image

Contents

1. Superficie di contatto Superficie di contatto del connettore Sub D del connettore Sub D 15 8 L 38 x 15 8 u 38 T 8 0 1 89 1 p x rn a T E p 2 LO O JON ol Joj f y DJ e LO B Y x je Yy pezzi MA 2 10 10 yA yA 2 77 RR ds i fz senza connettore fem con connettore femmina mina PG PG Figura F 3 Connettore di bus in IP 20 6ES7 972 0B 40 0XA0 15 Superficie di contatto a 56 gt del connettore Sub D A O m O aa O on EI off SIEMENS SET iiz 4 oO Figura F 4 Connettore di bus in IP 20 6GK1 500 0EA02 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA 36 4 D 72 7 W ls a Lo 35 Ye S68 wen Let Figura F 5 FastConnect connettore di bus 6ES7 972 0B 50 0XA0 Figura F 6 FastConnect connettore di bus 6GK1 500 0FC00 F 4 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA F 2 D
2. Fig 2 Network structure in an optical line topology Version 1 1 8 00 3 Network Topologies 3 1 Line topology In a line structure the individual PROFIBUS OLMs are connected together by dual fiber optical fibers Modules with one optical port are sufficient at the beginning and end of a line between which modules with two optical ports are necessary If single point to point connections are to be built up this can be achieved using two modules each with one optical port The line topology can be realized with and without fiber link monitoring If both operating modes are used within an optical fiber line the operating mode Line topology without fiber link monitoring determines the availability of this fiber line It is recommended that fiber link monitoring be used in homogeneous OLM networks default factory setting Please note that the following ambient conditions must be fulfilled to ensure that network configuration functions correctly The parameters MIN Tspg described in the PROFIBUS standard EN 50170 must be set to a value gt 11 on all terminals This is usually the case but the setting should be checked if communication malfunctions continuously arise When configuring your network select low bus subscriber addresses wherever possible This ensures that master timeout times which may arise are kept as short as possible
3. F 5 Disegni in scala del bus terminal BT12M m 5 A A SIEMENS SIMATIC NET 4 Bus terminal 12M 0 Tt oO vy o S 8 eeeese l ah 8 S e cai 1 Y 50 gt Figura F 11 Bus terminal BT12M su una guida profilata anorma con altezza di 15 mm Reti PROFIBUS SIMATIC NET F 8 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA F 6 Disegni in scala dell optical bus terminal OBT 86 gt re FT A A SIEMENS SIMATIC NET Optical On bus terminal Y D S ses ei gt Y TP 50 gt 64 WU 0000 138 Figura F 12 Optical bus terminal OBT su guida profilata a norma con altezza di 15 mm Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA SIEMENS SIMATIC NET PROFIBUS Optical bus terminal 0000 00000 6GK1500 3AA00 1121314151617 67 3 NEC CLASS2 24VDC 200 mA Figura F 13 Schema di foratura per optical bus terminal OBT Reti PROFIBUS SIMATIC NET F 10 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA F 7 Disegni in scala degli Infrared Link Module ILM 175 gt le 60 gt LY SIEMENS 2 oO J O i a oo 5 57 5 15 gt 87 5 Figura F 14 PROFIBUS
4. _ i SIEMENS OL O i e_ 06 O OFF ON 3 28 Od eooo T WE LI LILLO Am Collegamento del cavo di bus e posizione dell interruttore per tutte le altre stazioni sul bus Figura 4 24 Montaggio del connettore di bus con uscita assiale del cavo 4 44 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Montaggio del connettore di bus Per il montaggio del connettore di bus con uscita cavo assiale numero di ordina zione 6GK1 500 0EA02 necessario osservare quanto segue e Togliere l isolamento da entrambe le estremit del cavo in base alla figura 4 25 utilizzando il FastConnect Stripping Tool per la tabella delle quote vedere il lato posteriore dell attrezzo ca 6 mm 10 mm 7 5 mm Figura 4 25 Confezione delle estremit del cavo per il montaggio del connettore di bus con uscita cavo assiale e Allentare le viti del contenitore e togliere il coperchio e Inserire i conduttori nei relativi morsetti della morsettiera a vite e Premere la guaina del cavo tra i due inviti di fissaggio e Fare attenzione che gli schermi del cavo siano completamente appoggiati sulla guida di metallo e Avvitare le estremit d
5. Montaggio con guida profilata a norma sulla lamiera dell armadio a MADE IN GERMANY MADE IN GERMANY io 3 z Bus terminate N Lod Lasa Sg Glu N I e e e o Punto di T collegamento dello schermo e dle 8 Guida di terra 1 Se questo cavo di terra supera una lunghezza di 20 cm il collegamento a terra deve essere eseguito sulla lamiera dell armadio 2 lit Avvertenza La guida di terra e la terra locale devono essere collegate tra di loro sul percorso pi breve con un conduttore in rame con sezione di gt 6 mm Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Avvertenza La guida ad U deve deve disporre di una buona superficie elettrica di contatto p es stagnata Montaggio a parete Avvertenza In caso di montaggio a parete almeno un allacciamento PE del bus terminal deve essere collegato alla terra locale Questo collegamento deve essere possibilmente corto Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 59 Componenti passivi per reti RS 485 4 7 6 Dati tecnici del bus terminal RS 485 Dati tecnici del
6. ET200S m Repeater RS 485 OP 25 MER ET200M ET200M DI a Resistenza terminale attivata Figura 3 1 Struttura di una rete elettrica PROFIBUS con repeater RS 485 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 9 Progettazione di reti Progettazione Durante la progettazione di una rete elettrica con repeater RS 485 devono essere osservate le seguenti condizioni generali e Deve essere rispettata la lunghezza massima dei segmenti specificata per una velocit di trasmissione vedere tabella 3 1 tabella 3 3 tabella 3 6 e Il numero massimo di accoppiamenti di bus nodi repeater RS 485 OLM su un segmento limitato a 32 Con una velocit di trasmissione di 1 5 Mbit s possono risultare ulteriori limitazioni vedere capitolo 3 1 2 e Il numero massimo di nodi in una rete limitato a 127 e Tra due nodi possono essere installati al massimo 9 repeater RS 485 Reti PROFIBUS SIMATIC NET 3 10 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti 3 2 Progettazione di reti ottiche Parametri di progettazione per reti ottiche Durante la progettaz
7. PROFIBUS slave network segment 2 Figure 3 Cascading Two PROFIBUS ILM Transmission Links 13 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 A further application of a point to point link is described below Figure 4 shows how several slave network segments can be connected to one master network segment using their own infrared transmission links amp Once again make sure that the infrared transmission links do not interfere with each other in other words either the spatial arrangement of the modules clearance or a physical barrier wall must ensure that each PROFIBUS ILM can only detect the emission of its partner module and cannot detect emissions from the modules of the other infrared links If this is not guaranteed this can lead to problems in the master network segment The response of a slave node is detected at slightly different times in the master segment due to the unsynchronized operation of the PROFIBUS ILM causing pulses to be lost on the master network segment The advantage of this arrangement is that if there is a problem on an infrared link between two PROFIBUS ILMs only the connected slave segment is disconnected The master network segment and the other slave network segments retain their functionality This topology is also suitable when the PROFIBUS ILMs of the slave network segments cannot be arranged so that they are all located in the light cone of the PROFIBU
8. CH 2 ii R SE CH2 AA CH 2 OLM P11 E OLWP11 CH2 CH 2 OLM G11 OLM G11 1300 z A OLM G11 2 I A E N I Q y A Terminal unit A y bus segment A Terminal unit bus segment N i Yy Y T inal unit Erminat Uunl Yy Terminal unit bus segment Terminal unit bus segment bus segment Fig 3 Network structure in an optic star topology Several modules are combined to form an active PROFIBUS star coupler Other modules are connected to this by dual fiber optical fiber lines The modules of the star coupler are connected to one another via the electrical port electrical star segment All OLM types for different fiber types plastic PCF glass can be combined using the electrical star segment Please note CH1 in mode Monitor off S0 1 must be activated on all OLMs which are connected to the electrical star segment This deactivates the segmenting function of the RS 485 port on these OLMs providing a high degree of availability of the electrical star segment Ensure that the electrical star segment is wired carefully Keep it as small as possible to avoid interference injection into the electrical star segment and from here into the entire network This can be achieved by laying out the OLMs in the electrical star segment directly next to each other on a hat rail 12 Version 1 1 8 00 3 Network Topologies 3 2 Star topology Switch on the terminatin
9. eee eee eee eee nn 3 1 Progettazione di reti elettriche 0 ccc ccc eee 3 1 1 Segmenti per velocita di trasmissione fino ad un massimo di 500 kbit s 3 1 2 Segmenti per velocit di trasmissione 1 5 Mbit s 0005 3 1 3 Segmenti per velocita di trasmissione fino a max 12 Mbit s 3 1 4 Progettazione di reti elettriche con repeater RS 485 3 2 Progettazione di reti ottiche 00 sense nennen eee 3 2 1 Tipo di funzionamento di un sistema di trasmissione con cavi in fibra ottica 3 2 2 Bilancio ottico della potenzialit di un sistema di trasmissione FO 3 2 3 Lunghezze dei cavi per linee FO con fibre di plastica e PCF 3 2 4 Calcolo dell attenuazione del segnale di linee di trasmissione FO in fibra di vetro con OLM teen eens 3 3 Tempo di transito del telegramma 3 3 1 Progettazione di topologie lineari e a stella con OLM 3 3 2 Progettazione di anelli ottici ridondanti con OLM Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 3 3 Esempio per la progettazione dei parametri di bus in STEP 7 Componenti passivi per reti RS 485 eee 4 1 Cavi SIMATIC NET PROFIBUS cece eee ens 4 1 1 FC Standard Cable cavo standard 00 eee e eee ee 4 1 2 FC FRNC Cable cavo di bus con guaina esterna esente da alogeni 4 1
10. i284 5676 1 Plug connector for ribbon cable o oO 53337 Power supply and signaling contact oo 0 shared attachments H H I az ME Dea PROFIBUS cable Cable for power supply and signaling contact Cable clamps for contacting the shield Figure 6 Elements for Setting the Configuration of the PROFIBUS ILM 21 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 6 1 Setting the Terminating Resistor Electrical cables in aPROFIBUS network must be terminated with the characteristic impedance of the cable at the start and end of the bus Switch S202 is used for this purpose on the basic module of the PROFIBUS ILM Note Note that the switch must be set to terminating resistor activated if aPROFIBUS ILM is located at the start or end of an electrical PROFIBUS network only one PROFIBUS cable connected The switch must be set to terminating resistor deactivated if a PROFIBUS ILM is looped into a PROFIBUS network two PROFIBUS cables connected If the terminating resistor is not set correctly sporadic errors will occur on PROFIBUS that cannot be detected by the PROFIBUS ILM N SIEMENS a SIEMENS e S m je Terminating resistor Terminating resistor off on Figure 7 Setting the Terminating Resistor Copyright by Siemens 22
11. OLM Module P11 G11 P12 G12 G12 EEC G11 1300 G12 1300 Transmission distance with glass fiber E 10 125 0 5 dB km with glass fiber G 50 125 860 nm 3 0 dB km 1310 nm 1 0 dB km with glass fiber G 62 5 125 860 nm 3 5 dB km 1310 nm 1 0 dB km with PCF fiber S 200 230 Transmitting power Reduced Transmitting power Default 660 nm 10 0 dB km 860 nm 8 0 dB km with plastic fiber S 980 1000 Transmitting power Reduced Transmitting power Default 0 25 dB m 0 15000 m 0 3000 m 0 10000 m 0 3000 m 0 10000 m 0 400 m x 0 50 m 0 80m Connector BFOC 2 5 Electromagnetic compatibility EMC Interference emissions Limit class B EN 55022 Interference immunity against static charges At shielded socket and housing parts 8 kV contact discharge EN 61000 4 2 Immunity against high frequency interference 10 V m at 80 amplitude modulation with 1 kHz 80 MHz 1 GHz EN 61000 4 3 10 V m at 50 on period at 900 MHz ENV 50204 10 V m at 80 amplitude modulation with 1 kHz 10 kHz 80 MHz Immunity against line conducted disturbance Burst On power supply lines and shielded RS 485 bus lines 2 kV EN 61000 4 4 Immunity against line conducted disturbance Surge On power supply lines 1 kV symmetrical On shielded RS 485 bus lines 2 kV asymmetrical EN 61000 4 5 Climatic
12. 8 Co Infrared Link Modul ILM 6ZB530 3AC30 0BA1 10 Help With Problems During Operation 10 1 Status Displays for Incorrect Operation 10 2 Errors Due to Incorrect Network Configuration 10 2 1 Calculating the Propagation Time on Electric Cables and Fiber Optic Cables 10 2 2 Delay Time of the PROFIBUS ILM 10 2 3 Delay Time of Further Active PROFIBUS Network Components 10 2 4 Transmission Delay Time TTD 11 Technical Specifications 11 1 Illumination Range 12 Appendix 52 13 References 53 Copyright by Siemens 4 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 1 The Product 1 x PROFIBUS ILM 1 x sealing plugs for unused threaded cable inlet 1 x order form Not included with the product are gt Mounting brackets gt Cables for attaching to PROFIBUS or power supply cables gt Description and Operating Instructions Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 2 Symbols Master Slave HENDE LAN cable twisted pair Bus connector terminating resistor deactivated Bus connector terminating resistor activated Active or or passive bus node Passive bus node Infrared link module ILM terminating resistor activated Infrared link module ILM terminating resistor deactivated Important information and notes Sequence of actions to be performed by the user Copyright by Siemens 6ZB5
13. Avvertenza Le interfacce ottiche degli OLM sono ottimizzate per elevati raggi di azione L ac coppiamento diretto delle interfacce ottiche di un OLM con un OBT o interfacce ottiche integrate non ammesso a causa dei dati tecnici differenti Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS 1 2 6 Metodo trasmissivo per tecnica a raggi infrarossi senza fili Le reti PROFIBUS senza fili utilizzano raggi infrarossi per la trasmissione del se gnale Come mezzo trasmissivo necessario solo il collegamento a vista libero tra due nodi disposti uno di fronte all altro Il raggio di azione ca 15 m La realizza zione delle reti senza fili viene eseguita tramite Infrared Link Module ILM nodi da collegare in rete vengono allacciati all interfaccia elettrica dell ILM Vantaggi e Elevata libert di movimento di parti dell impianto accoppiati carrelli e Accoppiamenti e disaccoppiamenti con la rete fissa senza usura p es sostitu zione di anelli a strisciamento e Accoppiamenti senza installazione di cavi prevalentemente impianti settori non accessibili e Non in funzione del protocollo Separazione galvanica tra due nodi e la rete collegata con cavi Limitazioni e Velocit di trasmissione lt 1 5 Mbit s e necessario il collegamento a vista libero tra i due nodi e Raggio di azione lt 15m e Solo per reti mono master Propriet della tecnica trasmissiva a raggi i
14. Fascetta di schermatura per scarico di tiro del cavo per tensione di alimentazione Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 Dati tecnici La tabella 5 5 riporta i dati tecnici del PROFIBUS Terminator 5 16 Tabella 5 5 Dati tecnici del PROFIBUS Terminator Dati tecnici Tensione di alimentazione e Tensione nominale DC 24 V e Ondulazione limite statico da DC 20 4 V a DC 28 8 V Corrente assorbita alla tensione nominale max 25 mA Separazione di potenziale si DC 600 V Velocita di trasmissione da 9 6 kbit s a 12 Mbit s Classe di protezione IP 20 Temperatura ambiente ammessa da 0 C a 60 C Temperatura di magazzinaggio da 40 C a 70 C Cavi allacciabili tensione di alimentazione e cavi flessibili con capocorda senza capocorda e cavi massicci Tecnica ad avvitamento da 0 25 mm a 1 5 mm da 0 14 mm a 2 5 mm da 0 14 mm a 2 5 mm Cavi allacciabili PROFIBUS Tecnica ad avvitamento tutti i cavi SIMATIC NET PROFIBUS Dimensioni Lx Ax P in mm 601 701 43 Peso compresa confezione 95 g Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 Allacciamento del cavo di bus PROFIBUS Allacciare il cavo di bus PROFIBUS al PROFIBUS nel modo seguente 1 Tagliare il cavo di bus PROFIBUS nella lunghezza necessaria 2 Togliere l
15. nf T SO BI CH 1 Operating mode Electrical Port without segment monitoring 0 1 D ml ml CH1 is activated in this operating mode if SO is in Position 1 SO CH 1 Please note that this operating mode should only be set in the star segment of the star topology 4 3 2 2 Setting the operating mode of the optical ports CH2 CH3 The operating mode can be set individually for each optical port Combinations of the operating modes Line with optical fiber link monitoring and Line without optical fiber link monitoring are also possible Note that the operating mode of the two optical ports which are connected by the fiber line must always have the same settings The operating mode Redundant optical ring must always be set at both of the optical ports Operating mode Line with optical fiber link monitoring and segmentation 0 1 I CH3 CHS is activated in this operating mode if S3 and S4 are in Position 0 IHcH2 CH2 is activated in this operating mode if S1 and S2 are in Position 0 slot Operating mode Line without optical fiber link monitoring 0 1 CH CHS is activated in this operating mode if S3 is in Position 1 and S4 is in Position 0 CH 2 CH2 is activated in this operating mode if S1 is in Position 1 and S2 is in Position 0 alate 18 Version 1 1 8 00 4
16. 0 2 dB 5 Quantit 1 0 dB Asdopp Attenuazione della linea di trasmissione Alinea 10 0 dB Dati caratteristici degli OLM G11 1300 G12 1300 potenza accoppiabile nella fibra 62 5 125 um Pa min 17 dBm Sensibilit del ricevitore Pe min 29 dBm Valore massimo ammesso di attenuazione Amax Pa min Pe min 12 dB Riserve di sistema Amax Alinea 2 dB La linea di trasmissione pu essere realizzata nella forma prevista Avvertenza La lunghezza massima fornibile per il cavo FO in uno spezzone limitata in base al tipo di cavo a ca 3 km per ogni tamburo Per questo motivo tratte di cavo molto lunghe devono essere composte da diversi spezzoni Per il collegamento degli spezzoni necessario im piegare elementi di giunzione o sdoppiamenti che con la loro attenuazione riducano la lun ghezza massima realizzabile della linea Reti PROFIBUS SIMATIC NET 3 20 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Esempio per il calcolo di attenuazione in caso di impiego di OLM Attenuazione per OLM G11 G12 G11 1300 e G12 1300 per un collegamento punto a punto con lunghezza d onda A Attenuazione per cavo Tipo di fibra Attenuazione Lunghezza um aro in dB km cavo Lin km Attenuazione per elemento di giunzione ine Quantita Agiunz Attenuazione per collegamenti di sdoppiamenti zo B Quantit Asdopp Attenuazione della linea di trasmissione Alinea Potenza
17. 4 7 3 Struttura e tipo di funzionamento del bus terminal 12M 4 7 4 Montaggio collegamento del cavo i di DUS LL 4 7 5 Misure per il collegamento a terra 4 7 6 Dati tecnici del bus terminal RS 485 4 7 7 Dati tecnici del bus terminal 12M 00 cece eee 4 8 Collegamenti dei Cavi eee eens 4 8 1 Collegamento del cavo ai componenti della rete 4 8 2 Collegamento del cavo senza elementi di allacciamento del bus 4 9 Cavo di connessione confezionato 4 9 1 Cavo di connessione 830 1T 0 ccc cect ene eeee 4 9 2 Cavo di connessione 830 2 ccc ccc eee nennen nenn Componenti attivi per reti RS485 0 0 cece 5 1 Repeater RS 485 eee eee 5 2 Possibilit di configurazione con il repeater RS 485 5 6 5 3 Montaggio e smontaggio del repeater RS 485 5 9 5 4 Funzionamento del repeater RS 485 senza collegamento a terra Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 5 5 Allacciamento della tensione di alimentazione 5 13 5 6 Allacciamento del cavo di DUS en eens 5 14 5 7 PROFIBUS Terminator 00 00 00 cc cece eee 5 15 6 Componenti passivi per PROFIBUS PA 6 1 FC Process Cable cavo PROFIBUS PA cece eee 6 2 6 2 SpliTConnect Tap eee eens 6 3 7 Componenti passivi per r
18. Figura 3 1 Indicatori LED sul frontalino PROFIBUS Optical Busterminal OBT 3 3 C79000 G8972 C1 22 02 Descrizione del funzionamento 3 6 Elementi di comando L OBT stesso non dispone di elementi di comando E necessario fare attenzione solo che il cavo di collegamento PROFIBUS allacciato al canale 1 non compreso nella fornitura presenti delle terminazioni su entrambi i lati PROFIBUS Optical 3 4 Busterminal OBT C79000 G8972 C122 02 Topologia della rete 4 4 1 Linea ottica Gli OBT vengono collegati tra di loro insieme ad altri dispositivi SIMATIC come p es IM 153 2 FO o IM 467 FO sul PROFIBUS DP ottico sotto forma di una linea ottica AI canale 1 dell OBT vengono allacciati i singoli nodi di bus PROFIBUS DP con interfaccia RS485 con un cavo di bus PROFIBUS lungo max 100 m confezionati su entrambi i lati con connettori di allacciamento al bus La terminazione del con nettore di allacciamento al bus deve essere attivata E possibile allacciare un nodo di bus PROFIBUS DP attivo o passivo L OBT pu essere inserito in un punto qualsiasi della linea ottica Se OBT viene inserito all inizio o alla fine il canale ottico non utilizzato deve rimanere chiuso con i tappi di gomma compresi nella fornitura In questo modo possibile evitare un im brattamento degli elementi ottici e disturbi provocati dall incidenza di luce Il collegamento in una linea ottica viene eseguito con cavi a due fibre ottic
19. General current information is available on the Internet at http www ad siemens de net Current product information and downloads which could be useful when using our products are available on the Internet at http www ad siemens de csi net Source for special cables Special cables and cable lengths for all SIMATIC NET cables are available on request from A amp D SE V22 WKF F rth Germany Mr Hertlein Telephone 49 911 750 4465 Fax 49 911 750 9991 E Mail juergen hertlein fthw siemens de Further support If you have any more questions about SIMATIC NET products please contact your Siemens contact partner at your local or regional branch office The addresses can be found in our catalogue IK 10 on the Internet at http www ad siemens de Siemens AG 1999 Subject to alteration Siemens AG Order No 6ZB5530 3AD00 0BAO Printed in Germany Version 1 1 8 00 37 SIEMENS Prefazione indice Introduzione SIMATIC NET N Fornitura dell OBT PROFIBUS Optical Busterminal OBT oO Descrizione del funzionamento Topologia della rete Messa in funzione Manuale gr e n Rimedi in caso di disturbi di funzionamento Dati tecnici Avvertenze relative al marchio CE O 00 Bibliografia O Indice delle abbreviazioni C79000 G8972 C122 02 Versione 2 Avvertenze tecniche di sicurezza PP Il presente manuale contiene avvertenze tecniche relative alla sicure
20. A A A N N N N v v y v Terminal unit bus segment Terminal unit bus segment Terminal unit bus segment Fig 4 Network structure in a redundant optical ring topology Version 1 1 8 00 Terminal unit bus segment 13 3 Network Topologies 3 3 Redundant optical ring This network topology represents a special form of line topology A high degree of network operating safety is achieved by closing the optical line A redundant optical ring can only be realized with modules with two optical ports of the same type Monitoring mechanisms Send echo yes Monitor echo yes Suppress echo yes Segmentation yes An interruption of one or both optical fibers between two modules is detected by the OLM and the ring is trans formed into an optical line If one module fails only those terminals connected to this module or the RS 485 segment are uncoupled from the ring The remainder of the network itself continues to function as a line The error is indicated by the LEDs on the two OLMs connected to the malfunctioning optical fiber and their signaling contacts The segmentation is lifted auto matically as soon as both modules recognize that the segmented field bus network is functioning correctly with the help of test frames The line forms itself into a ring Please note The following ambient conditions must be fulfilled to ensure that the network configuration functions correctly Only use this ope
21. Typ Type Beschreibung Description Bestell Nummer Ord code FastConnect Stripping Tool Werkzeug zum einfachen und 6GK1905 6AA00 schnellen Abisolieren des PROFIBUS FC Process Cable 1 Tool for simple and fast insulation of the PROFIBUS FC Process Cable 1 1 siehe Montageschritt 2 see mounting step 2 Copyright 1999 Siemens AG Montageanleitung f r SIMATIC NET PROFIBUS SpliTConnect System Mounting Instruction for SIMATIC NET PROFIBUS SpliTConnect System Technische Daten Technical Data Elektrische Daten Electrical data gem PROFIBUS Spezifikation IEC 61158 2 according PROFIBUS specification IEC 61158 2 Schutzart Protection class IP 67 D Kontaktierh ufigkeit 4 mal 2 4 times 2 Contacting amount 1 nur wenn alle Abg nge ordnungsgem best ckt sind only if all user ports are mounted correctly 2 wenn erneut kontakiert wird mu die Leitung unbedingt neu abgesetzt werden if cable is connected again it has to be stripped off new Lieferumfang SpliTConnect Tap Scope of delivery SpliTConnect Tap 1x SpliTConnect Tap 1 x Kontaktierelement Contacting element 3 x Mutter M22 Nut M22 3 x Dichtung Seal 3 x Schirmkontaktierungselement Shield contacting element 3 x Litzenhalter Strand holder 3 x Dichtscheibe Sealing disk 1 x SpliTConnect Clip Copyright 1999 Siemens AG Componenti passivi per reti ottiche Reti
22. e DP con S5 95U anello ottico ridondante Velocit di a b c trasmissione 12 Mbit s 1651 240 28 6 Mbit s 951 120 24 3 Mbit s 551 60 24 1 5 Mbit s 2011 30 24 500 kbit s 771 10 24 187 5 kbit s 771 3 75 24 93 75 kbit s 451 1 875 24 45 45 kbit s 851 0 909 24 19 2 kbit s 181 0 384 24 9 6 kbit s 171 0 192 24 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 29 Progettazione di reti 3 30 Avvertenza Il calcolo del tempo di slot include solo la rete ottica e l allacciamento dei nodi di bus all OLM con un segmento di bus RS 485 con una lunghezza di rispettivamente max 20 m Segmenti di bus RS 485 pi lunghi devono essere calcolati somman doli alla lunghezza fo Con velocit di trasmissione di 12 Mbit s 6 Mbit s 3 Mbit s und 1 5 Mbit s per OLM G11 1300 e OLM G12 1300 necessario rispettare i tempi minimi di slot in base alla seguente tabella Tabella 3 11 Tempo minimo di slot per OLM G11 1300 e OLM G12 1300 Velocit di trasmissione Tempo minimo di slot 12 Mbit s 3800 tpit 6 Mbit s 2000 tpit 3 Mbit s 1000 tpit 1 5 Mbit s 530 tgit Se il tempo di slot calcolato inferiore del tempo minimo di slot per il tempo di slot da progettare utilizzare il tempo minimo di slot in base alla tabella 3 11 Avvertenza Se il tempo di slot viene progettato con un valore troppo basso possono verific
23. Installazione di componenti di rete in un gt armadio E 1 Grado di protezione IP componenti elettrici sono normalmente montati in una custodia di protezione Questa custodia serve inoltre come e protezione da contatto per le persone in caso di parti sotto tensione o in movi mento protezione da contatti accidentali e protezione dei componenti contro la penetrazione di corpi estranei solidi prote zione contro corpi estranei e protezione dei componenti contro la penetrazione di acqua protezione contro acqua IEC 60529 EN 60529 Il grado di protezione indica in che misura una custodia risponde alle tre funzioni di protezione sopraindicate UT gradi di protezione sono definite a livello internazionale nell International Stan dard IEC 60529 o identici alla norma europea EN 60529 La specificazione del grado di protezione di una custodia avviene sotto forma di una sigla La sigla costituita dalle lettere distintive invariate IP International Pro tection e dalla cifra identificativa per la protezione da contatto e da corpi estranei nonch da acqua e viene rappresentata nel modo seguente IP 54 Lettera di codifica International Protection 1 Cifra identificativa da 0 a 6 Protezione da contatto e da corpi estranei 2 Cifra identificativa da 0 a 8 Protezione da acqua A seconda dei casi il grado di protezione viene specificato pi dettagliatamente con l aggiunta di lettere o cifre i
24. Numero di ordinazione SIMATIC NET PROFIBUS Plastic Fiber Optic con conduttori Anello di 50 6XV1821 2AN50 duplex m I VY2P 980 1000 150A Cavo in fibra ottica di plastica con due conduttori guaina in PVC senza connettore per l impiego in ambienti con carico meccanico ridotto p es all interno di un armadio o per strutture di test in laboratorio Reti PROFIBUS SIMATIC NET 7 6 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche 7 2 2 Fibre ottiche Figura 7 2 Plastic Fiber Optic cavi standard Guaina esterna in PVC Scarico di tiro in kevlar Foglio di protezione Guaina in poliammide Principio di struttura del Plastic Fiber Optic cavo standard Cavo in fibra ottica di plastica cavo standard 6XV1821 0A Il cavo in fibra ottica di plastica cavo standard 6XV1821 0A composto da due fibre di plastica con una resistente guaina interna di poliammide rivestita con ele menti di tiro in kevlar e una guaina esterna di colore lilla in PVC La sigla identifica tiva a norma I VY4Y2P 980 1000 160A Sulla guaina esterna stampata la scritta SIEMENS SIMATIC NET PLASTIC FIBER OPTIC 6XV1821 0AH10 UL e un contrassegno che indica la lunghezza Il cavo pu essere facilmente confezionato nel luogo di installazione Per apparec chi con interfacce ottiche integrate il cavo previsto con 2x2 connettori simplex Per l impiego di OLM P11 e OLM P12 il cavo deve essere co
25. PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 1 Il PROFIBUS OBT Optical Bus Terminal un componente di rete per l impiego in reti ottiche con bus di campo PROFIBUS DP Esso permette l allacciamento di un singolo dispositivo al PROFIBUS DP ottico senza interfaccia ottica integrata La seguente figura illustra un esempio di configurazione Introduzione PC ET200M con Nodo DP senza SIMATIC S7 400 ottica integrata Disp di programm ottica integrata con IM467 FO Operator Panel OBT Resistenza terminale attivata 1 Linea PROFIBUS con terminazione su entrambi i lati 2 Cavo a fibre ottiche di plastica o PCF a due fibre Figura 1 1 Esempio di configurazione di PROFIBUS DP ottico PROFIBUS Optical Busterminal OBT 1 1 C79000 G8972 C1 22 02 Introduzione Collegame Sensibilit nti Il collegamento dei singoli nodi di bus viene eseguito sotto forma di una linea ottica con cavi a due fibre ottiche di plastica i cavi a fibre ottiche di plastica vengono contrassegnati anche come POF Polymer Optical Fiber o cavi a fibre ottiche PCF PCF Polymer Cladded Fiber con lo stesso significato di cavi a fibre ottiche HCS 1 Poich i cavi a fibre ottiche FO sono completamente immuni agli irra diamenti EMC non sono pi necessari i complicati concetti di messa a terra e i provvedimenti di protezione Ci vale anche per la posa dei cavi con compensa zione del potenziale Grazie alla c
26. S7 1 Compatibility Mode ON SO Reserved SI Mode Monitor 0 Line Ring On 1 Line Off S2 Redundancy 0 Off 1 On 3 Distance 0 Extended 1 Standard S4 55 S6 Reserved SO Reserved S1 Mode Monitor 0 Line Ring On 1 Line Off S2 Redundancy 0 Off 1 On S3 S4 Reserved S5 Output Power CH3 0 Standard 1 High S6 Output Power CH4 0 Standard 1 High OLM P3 S6 reserved OLM S3 OLM S3 1300 S2 reserved Version 1 1 8 00 can be found in the Description and Operating Instructions SINEC L2 Optical Link Module OLM P OLM S for this SINEC L2 OLM 17 4 Setting Up 4 3 Setting compatibility operating mode and transmitting power 4 3 2 Setting the operating mode Attention The following details only apply for the S7 default position S7 0 The DIL switch SO is used to set the operating mode of the electrical port CH1 The DIL switches S1 and S2 are used to set the operating mode of the optical port CH2 The DIL switches S3 and S4 are used to set the operating mode of the optical port CH3 S3 and S4 do not have a function on OLMs with only one optical interface 4 3 2 1 Setting the operating mode of the electrical port CH1 Operating mode Electrical Port with segment monitoring 0 1 Eq IM Te ge Ta a CH1 is activated in this operating mode if SO is in Position 0
27. SIMATIC NET Comunicazione industriale catalogo IK10 SIEMENS AG Bereich Automatisierungstechnik Gesch ftszweig Industrielle Kommunikation SIMATIC NET Postfach 4848 D 90327 N rnberg SIMATIC NET Informazioni sul prodotto Istruzioni di montaggio per SIMATIC NET PROFIBUS Plastic Fiber Optic con connettore simplex Queste istruzioni di montaggio si trovano in Internet tedesco http Awww ad siemens de csi net inglese http Awww ad siemens de csi_e net Selezionare in questa pagina di Internet SEARCH funzione di ricerca immettere il numero 574203 sotto ID e avviare l operazione di ricerca SIMATIC NET Descrizione e istruzioni per l uso OLM12M SIEMENS AG Numero di ordinazione 6ZB5530 3AB00 0BA0 9 1 C79000 G8972 C1 22 02 PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Indice delle abbreviazioni DIN ESD EN EMC IEEE ISO OSI HCS LAN LED FO OBT OLM PCF PNO POF PROFIBUS DP SELV UL VDE PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 10 Norma industriale tedesca Componenti elettrostatici Norma europea Compatibilit elettromagnetica Institution of Electrical and Electronic Engineers International Standards Organization Open System Interconnection HCS un marchio registrato di Ensign Bickford Optics Company e sta per Hard Polymer Cladded Silica Fiber Nelle presenti Istruzioni per l uso viene utilizzata
28. corrections included in subsequent editions Suggestions for improvement are welcome Technical data subject to change Copyright Siemens AG 1999 All Rights Reserved Note We would point out that the contents of this product documentation shall not become a part of or modify any prior or existing agreement commitment or legal relationship The Purchase Agreement contains the complete and exclusive obligations of Siemens Any statements contained in this documentation do not create new warranties or restrict the existing warranty We would further point out that for reasons of clarity these operating instructions cannot deal with every possible problem arising from the use of this device Should you require further information or if any special problems arise which are not sufficiently dealt with in the operating instructions please contact your local Siemens representative WARNING The tools described in these instructions are intended only for stripping the jackets from SIMATIC NET PROFIBUS Plastic Fiber Optic cables Using the tools for any other purpose can lead to injury or to damage of the tools or cable Under no circumstances must the tools be used on live cables Personnel qualification requirements Qualified personnel as referred to in the operating instructions or in the warning notes are defined as persons who are familiar with the installation assembly startup and operation of this product and who possess the re
29. onda e dagli elementi di collegamento impiegati ricevitori sono caratterizzati dalla loro sensibilit ottica e dal loro campo dinamico Durante la progettazione di una linea ottica necessario fare attenzione che la potenza a disposizione sui ricevitori non esca dal loro campo dinamico Se il valore scende al di sotto della potenza minima necessaria si verifica un aumento del BER Bit Error Rate tasso di errore sui bit dovuto ad una distanza di sicurezza dal rumore proprio del ricevitore insufficiente Il superamento del livello di ricezione massimo ammesso comporta un aumento delle distorsioni dell impulso dovute agli effetti di saturazione e di sovraccarico e di conseguenza anche un aumento del tasso di errore sui bit Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Budget di attenuazione Oltre all attenuazione della fibra agli effetti della temperatura e dell invecchiamento il budget di attenuazione di una linea ottica di trasmissione tiene in considerazione anche i valori di attenuazione dei punti di giunzione e di sdoppiamento e fornisce cos informazioni esatte sulla possibilit di realizzazione di un collegamento FO Il risultato del calcolo delle lunghezze massime realizzabili della linea la potenza minima di trasmissione accoppiabile nel relativo tipo di fibra Il calcolo del budget viene eseguito in in dBm e dB Dalla potenza minima di trasmissione vengono sottratte
30. significa che la non osservanza delle relative misure di sicurezza provoca la morte gravi lesioni alle Pericolo gt persone e ingenti danni materiali significa che la non osservanza delle relative misure di sicurezza pu causare la morte gravi lesioni alle Attenzione gt sone o lievi danni materiali singifica che la non osservanza delle relative misure di sicurezza pu causare leggere lesioni alle per Avvertenza un informazione importante sul prodotto sull uso dello stesso o su quelle parti della documentazione a cui si deve presare una particolare attenzione Personale qualificato La messa in servizio e il funzionamento di un dispositivo devono essere eseguiti esclusivamente da personale qualificato Personale qualificato ai sensi delle avvertenze di sicurezza contenute nella pre sente documentazione quello che dispone della qualifica a inserire mettere a terra e contrassegnare secondo gli standard della tecnica di sicurezza apparecchi sistemi e circuiti elettrici Uso conforme alle disposizioni Pericolo Osservare quanto segue Il dispositivo deve essere impiegato solo per l uso previsto nel catalogo e nella documentazione tecnica e solo in combinazione con apparecchiature e componenti esterni omologati dalla Siemens Per garantire un funzionamento inaccepibile e sicuro del prodotto assolutamente necessario un tras porto immagazzinamento un installazione ed
31. 23 4 Setting Up 4 4 Installation FI F2 SS8ssi Fig 12 Signaling contact pin assignment 5 pin terminal block Pin assignment 5 pin terminal block terminals F1 and F2 Always ensure that the pins are correctly assigned at the 5 pin terminal block Make sure that the connecting leads of the signaling contacts are adequately insula ted particularly if you are working with voltages greater than 32 V Incorrect assignment can lead to destruction of the module 4 4 6 Defining the receiving level of the optical ports system C O OO n m CH2 CH1 CH2 CH3 Measuring sockets e CH3 Receive Signal Intensity Reference potential GND O Fig 13 Location of the measuring sockets 24 The receiving level of the two optical Ports CH2 and CH 3 can be measured using a conventional voltmeter con nected to the measuring sockets The voltmeter can be connected and disconnected while the module is in operation without any interference using 2 mm laboratory test plugs The OLM is protected against short circuits at the measu ring sockets although data transmission may be briefly disrupted With this the incoming optical performance can be documented e g for later measurements ageing damage a good poor check can be carried out limit value Further information can be found in Appendix 8 4 Measuring sockets p 35 On
32. SIMATIC NET Description and Operating Instructions Stand Dated 1 00 Order Number 6ZB5530 3AC30 0BA1 PROFIBUS ILM Infrared Link Module Im Nachfolgenden finden Sie Informationen in deutscher Sprache The following description contains information in English SIEMENS AG 1998 Anderungen vorbehalten Subject to change Sous r serve de modifications Con riserva di modifiche Hinweis Note Avertissement Avvertenza Indicati n Achtung Vorder Inbetriebnahme Hinweise in der entsprechenden aktuellen Dokumentation beachten Die Bestelldaten hierf r entnehmen Sie bitte den Katalogen oder wenden Sie sich an Ihre rtliche SIEMENS Niederlassung Die Inbetriebnahme ist solange untersagt bis festgestellt wurde da die Maschine in die diese Komponente eingebaut werden soll den Bestimmungen der Richtlinie 89 392 EWG entspricht Attention Priorto startup you must observe the notes in the relevant documentation For ordering data ofthe documentation please refer to catologs or contact your local SIEMENS representative Startup must not take place until it is established that the machine which is to accommodate this component is in conformity the guideline 89 392 EEC Attention Avant la mise en service respecter les instructions de la documentation actuelle correspondante Pour les r f rences de com mande de la documentation veuillez vous reporter aux catalogues ou consulter votre agence locale SIEMENS La mise en s
33. Slit the outer jacket up to the end of the cable Remove the jacket If the jacket is difficult to remove the cutting depth is not adequate In this case increase the cutting depth by turning the adjusting screw of the cable knife clockwise Try out the setting by stripping a piece of cable again If the foil and the buffer are damaged the cable knife is set too deep In this case reduce the cutting depth by turning the adjusting screw in the handle counter clockwise Try out the setting by stripping a piece of cable again Cut section of jacket with a correctly set cable knife Page 5 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors Stripping the Outer Jacket of the SIMATIC NET PLASTIC FIBER OPTIC Standard Cable Press the clamp of the cable knife in the Rotate the cable knife twice Slit the outer jacket up to the end of the direction of the arrow Insert the cable up cable to a length of 20 cm if you are fitting a plug adapter 30 cm Note The cable knife must be set to a cutting depth of 1 5 mm di Remove the outer jacket Kevlar fibers and foil working from the end of the cable towards the round cut leaving the black and orange FO cords Make a second slit up to the end of the cable on the opposite side of the jacket First turn the cable through 180 Then make a second slit up to the end of the cable starting f
34. Struttura 9 2 L Infrared Link Module ILM serve per la trasmissione senza fili di PROFIBUS in area limitrofa lt 15m LILM permette di accoppiare singoli nodi ad un segmento oppure di accoppiare due segmenti L ILM permette la comunicazione tra nodi in movimento p es sistemi di trasporto senza conducente FTS oppure con nodi che si avvicendano in sequenza p es lungo stazioni di linee di trasporto e nastri di produzione L ILM permette di realizzare impianti e configurazioni di durata limitata p es strut ture per test Con l ILM possibile sostituire sistemi soggetti ad usura p es anelli e conduttori a strisciamento Un ILM illumina una superficie circolare con diametro di 4 m ad una distanza di 11m e Contenitore a getto di alluminio con classe di protezione IP 65 e Morsettiera a 2x2 poli nel contenitore con allacciamento cavo tramite collega mento a vite PG per l allacciamento del segmento PROFIBUS e Morsettiera a 4 poli nel contenitore con allacciamento cavo tramite collega mento a vite PG per l allacciamento della tensione di alimentazione 24V DC e del contatto di segnalazione e Cablaggio permanente vale a dire sostituzione semplice e rapida dell elettro nica in caso di guasto e Segnalazione dello stato di funzionamento tramite LED e Impostazione della velocit di trasmissione tramite selettore interno e Protezione contro infiltrazioni di luce dell ambiente circostante che possono cr
35. The cable clamp in the device itself is only intended for low resistance discharge of spurious voltages on the shield The threaded cable inlet is used only for sealing the cable entry and to prevent the cable being pulled out accidentally Neither of these however is intended as strain relief against continuous tensile stress on the cables 37 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 8 2 Connecting the Power Supply and the Signaling Contact Use a two wire round cable if you do not want to use the signaling contact or a four wire round cable ifthe signaling contact is required This is necessary so that the threaded cable inlet seals the cable entry and prevents the cable from being pulled out Ideally you should use twisted pair cables since they are less susceptible to noise The outer diameter of the cables must be between 7 5 and 10 mm Do not connect power supply or signaling contact cables that are laid partly or completely outside buildings without first providing a suitable surge voltage protector to protect the PROFIBUS ILM and your low voltage network Otherwise lightning strikes in the area can destroy the PROFIBUS ILM or other network components If the cable is laid outside buildings and in cable cable conduits along with cables supplying power you should also use a shielded cable for the power supply and signaling contact to prevent interference from the power cables Connect the power supply
36. comportare disturbi di funzionamento Reti PROFIBUS SIMATIC NET 4 32 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 3 1 Settore di impiego e dati tecnici del connettore di bus Settore d impiego connettori di bus sono necessari per allacciare il cavo di bus PROFIBUS all inter faccia Sub D a 9 poli Esistono diversi connettori di bus con classe di protezione IP 20 La tabella 4 6 riporta i diversi tipi di impiego Tabella 4 6 Struttura e settore di impiego dei connettori di bus IP 20 Numero di 6ES7 972 0BA11 0X 6ES7 972 0BA40 0XA0 6ES7 6GK1 ordinazione AO 6ES7 972 0BB40 0XA0 OBA30 0XA0 500 0EA02 6ES7 972 0BB11 0X AO Aspetto a SIEMENS Uy SIL Uscita cavo a 35 Uscita cavo a 30 Raccomandato per e IM 308 B Q a partire dalla ver 9 9 sione 6 e IM308 C 9 9 9 e S5 95U 9 9 Impiego in AG con interfaccia integrata e S7 300 9 9 9 e S7 400 Q Q Q e M7 300 9 Q e M7 400 Q Q Impiego in AG con e IM308C 9 9 e CP 5431 9 9 9 FMS DP e CP342 5 9 9 9 e CP343 5 9
37. essa deve essere montata nel e contenitore di protezione art N 906055 come descritto nelle istruzioni di installazione della protezione di massima a a a gt Figura B 3 Protezione di fine nell armadio di comando nelle vicinanze del primo nodo di bus Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Protezione contro fulmini e sovratensioni per cavi di bus che si estendono in pi edifici B 2 3 Istruzioni generali per il dispositivo di protezione antifulmine della ditta Dehn amp S hne e Per il montaggio dei moduli necessario osservare i dati del prodotto specificati dalla ditta Dehn amp S hne e In caso di guasto di un modulo di protezione antifulmine viene interrotta la co municazione sul bus cortocircuito del cavo Per riprendere provvisoriamente la comunicazione senza protezione antifulmine possibile rilevare i moduli di protezione dai moduli di base in questo essi funzionano senza modulo di prote zione come morsetti di passaggio e Inoltre il concetto di protezione dell impianto pu essere progettato in base a VDE 0185 parte 103 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 B 7 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 1 Installazione dei cavi di bus C 1 Cavi di bus in impianti di automazione Cavi di bus co
38. ferenza tra la potenza ottica di una determinata fibra accoppiata da un trasmetti tore ottico e la potenza di ingresso di cui necessita un ricevitore ottico per l identi ficazione corretta del segnale Bus Percorso di trasmissione comune al quale sono collegati tutti i nodi dispone di due terminazioni definite Nel PROFIBUS il bus un cavo a due conduttori o in cavo in fibra ottica Cavo in fibra ottica FO Un cavo in fibra ottica rappresenta il mezzo trasmissivo nella rete ottica Compatibilit elettromagnetica EMC La compatibilit elettromagnetica EMC racchiude tutti i quesiti sugli effetti di immissione ed emissione elettrici magnetici ed elettromagnetici e di conse guenza sui disturbi di funzionamento derivanti da apparecchi elettrici Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Glossar 1 Glossario Conduttore di protezione antifulmine sono in grado di deviare correnti multiple di fulmini o parti di esse senza distrug gere componenti Conduttore di protezione contro sovratensioni serve a limitare sovratensioni da scariche di fulmini distanti o da effetti di indu zione o comandi conduttori di protezione contro sovratensioni collegano a terra al contrario dei conduttori di protezione antifulmine correnti con valori di picco cariche ed energie specifiche notevolmente inferiori Connettore di bus Collegamento fisico tra nodo e cavo di bus Per SIMATIC NET esistono connettori d
39. per esterno Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Tabella 7 5 Dati tecnici del cavo da trascinamento flessibile Fiber Optic e del cavo marino in fibre ottiche duplex SIENOPYR Tipo di cavo Fiber Optic flessibile SIENOPYR Tipo di conduttore Cavo da trascinamento Conduttore cavo riempito Cavo marino duplex in fibra ottica Conduttore pieno Materiali elemento di base PUR nero Poliolefina Scarico di tiro Elemento centrale in plastica e fibra di vetro filati aramidici Filati aramidici Guaina esterna colore del cavo PUR nero Composizione SHF1 nero Dimensioni elemento di base 3 5 0 2 mm 2 9 0 2 mm Dimensioni esterne ca 12 9 mm 13 3 0 5 mm Peso del cavo ca 136 kg km ca 220 kg km Forza di tiro ammessa lt 2000 N momentanea lt 1000 N continuativa lt 500 N momentanea lt 250 N continuativa Raggi di curvatura 150 mm max 100 000 cicli di curvatura 133 mm un unico ciclo di curvatura 266 mm diversi cicli di curvatura Temperatura per la posa da 5 C a 50 C da 10 C a 50 C Temperatura d esercizio da 25 C a 60 C da 40 C a 80 C 1 da 40 C a 70 C 2 Temperatura di magazzinaggio da 25 C a 70 C da 40 C a 80 C Resistenza alla fiamma secondo IEC 60332 1 secondo IEC 60332
40. sive Saremo lieti di ricevere qualunque tipo di proposta di miglioramento Siemens AG 1998 Con riserva di modifiche tecniche Siemens Aktiengesellschaft N di ordinazione C79000 G8972 C122 Indice Indice 1 Introduzione iur a a in te 1 1 Fornitura di SIMATIC NET PROFIBUS OBT 2 1 3 Descrizione del funzionamento renee eee ee eens 3 1 3 1 Interfacce 2 2 ead Le re el ila peated ia dee lek 3 1 3 2 Conversione del segnale elettro ottico e rigenerazione del segnale 3 1 3 3 Identificazione automatica della velocit di trasmissione 3 2 3 4 Tipi di fibre ottiche supportate eee 3 2 3 5 Indieat n 232er een ee ee dea 3 2 3 6 Elementi di comando nern nern een nenn 3 4 4 Topologia della rete rr 4 1 Linea ottica un a a a e ee 4 1 4 2 Collegamenti di lunghi percorsi di cavi a fibre ottiche 4 2 4 3 Collegamento di segmenti R8485 eee 4 2 5 Messa in funzione Li i i 5 1 5 1 Procedimento per la messa in funzione LL 5 2 5 2 Inst llazi ng 2 20 02 ie ia bi 5 3 6 Rimedi in caso di disturbi di funzionamento 7 Dati tCCnich 2 a aa 7 1 8 Avvertenze relative al marchio CE L Lei 9 Bibliografia soho 10 Indice delle abbreviazioni Lera PROFIBUS Optical Busterminal OBT i C79000 G8972 C122 02
41. the device sockets The optical transmitter and receiver elements could otherwise be destroyed When fitting the cable to connectors make sure that the transmit and receive lines are crossed over Page 3 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors Setting the Cutting Depth of the Cable Knife Set the cutting depth of the cable knife The cutting depth is set using the for stripping the outer jacket of the adjusting screw at the end of the handle SIMATIC NET PLASTIC FIBER OPTIC standard cable to a depth of 1 5 mm Then follow the steps as described below Try out the cutting depth Press the clamp of the cable knife in the the cutting depth e Turning the screw counter clockwise reduces the cutting depth Rotate the cable knife twice Slit the outer jacket up to the end of the cable Remove the jacket If the jacket is difficult to remove the cutting depth is not adequate In this case increase the cutting depth by turning the adjusting screw of the cable knife clockwise Try out the setting by stripping a piece of cable again If the foil and the buffer are damaged the cable knife is set too deep In this case reduce the cutting depth by turning the adjusting screw in the handle counter clockwise Try out the setting by stripping a piece of cable again Cut section of jacket with a correctly set cable knife Page
42. 05 2000 DISEGNI IN SCALA Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 F 1 DISEGNI IN SCALA F 1 Disegni in scala dei connettori di bus Superficie di contatto Superficie di contatto del del connettore Sub D connettore Sub D 15 8 34 15 8 34 902 802 4 1 lo renna LI ol Lo SIEMENS E SIEMENS P o 4 LO 1 N 6 i 1 N i ta amp az 3 E ds 10 5 10 on i on fe gt ele Ji a senza connettore femmina PG con connettore femmina PG Figura F 1 Connettore di bus in IP 20 6ES7 972 0B 11 0XA0 15 4 34 Superficie di contatto e ea del connettore Sub D Fx O a de o o a2 wo 0 8 1 N o LO m O co 1 LO gt 10 O 7 v Figura F 2 Connettore di bus in IP 20 6ES7 972 0BA30 0XA0 Reti PROFIBUS SIMATIC NET F 2 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA
43. 0B 11 Aprire il contenitore del connettore di bus allentando le viti del contenitore e to gliendo il coperchio Inserire i conduttori verdi e rossi nella morsettiera a vite in base alla figura 4 17 Durante questa operazione fare attenzione che vengano allacciati sempre gli stessi conduttori agli stessi allacciamenti A o B p es allacciamento A sempre con il filo verde e allacciamento B con il filo rosso Premere la guaina del cavo tra i due inviti di fissaggio In questo modo il cavo viene fissato Serrare i conduttori verdi e quelli rossi nel morsetto a vite Collegamento del cavo di Collegamento del cavo di bus per la prima e l ultima bus per tutte le altre sta stazione sul bus zioni sul bus Z Y oti F Wo DT 1 Il cavo di bus deve sempre essere collegato a sinistra Figura 4 17 Collegamento del cavo di bus al connettore di bus 6ES7 972 0B 11 6 Avvitare il contenitore 4 38 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Durante questa operazione fare attenzione che lo schermo del cavo appoggi completamente sotto la fascetta di schermaggio Avvertenza conduttori a trefoli possono essere avvitati solo con l aiuto di capicorda 0 25 mm secondo DIN 46228 Utilizzare solo copicorda di materiale con propriet di contatto a stabilit permane
44. 1 2 2 Metodo di accesso Metodo TOKEN BUS master slave 1 8 Nel PROFIBUS l accesso alla rete corrisponde al metodo definito in EN 50170 volume 2 del Token bus per stazioni attive e del Master slave per stazioni pas sive Circolazione del token Master Master Master anol BIKO i Master Slave Slave Slave Slave Slave Master nodo di bus attivo ee Anello token logico slave nodo di bus passivo Sa Rapporto master slave Figura 1 1 Principio del funzionamento del metodo di accesso PROFIBUS Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS Nodi attivi e passivi Il metodo di accesso non dipende dal mezzo trasmissivo La figura 1 1 Principio di funzionamento del metodo di accesso PROFIBUS illustra il metodo ibrido impie gato con nodi attivi e passivi Questo metodo viene qui di seguito descritto breve mente Tutti i nodi attivi master formano in un ordine di successione stabilito l anello di token logico nel quale ogni nodo attivo a conoscenza degli altri nodi attivi e della loro sequenza nell anello logico l ordine di successione non dipende dall assegnazione topologica dei nodi attivi sul bus L autorizzazione di accesso al mezzo il token viene passata da nodo attivo a nodo attivo in base all ordine di successione stabilito dall anello logico Se un nodo ha ricevuto il token ad esso indirizzato esso pu trasmettere dei teleg
45. 1x2x0 64 2 55 1x2x0 64 2 55 Y Y CY2Y 150 KF 40 150 VI KF25 1x2x0 64 2 55 1x2x0 64 2 55 1x2x0 64 2 55 FRNC VI FRNC 150 KF40 150 KF40 150 KF 40 SW FRNC VI Guaina esterna Materiale PVC FRNC PE PUR PE PVC Colore viola viola chiaro nero viola nero Diametro 8 0 0 4 mm 8 0 0 4 mm 8 0 0 4 mm 8 0 0 4 mm ave 0 5 mm 3 Condizioni ambientali ammesse Temperatura d esercizio 40 C 60 C 25 C 60 C 40 C 60 C 40 C 60 C 40 C 60 C Temperatura di trasporto 40 C 60 C 25 C 60 C 40 C 60 C 40 C 60 C 40 C 60 C di magazzinaggio Temperatura di posa 40 C 60 C 25 C 60 C 40 C 60 C 40 C 60 C 40 C 60 C Raggi di curvatura per una curvatura gt 75mm gt 75mm gt 75mm gt 75mm gt 80mm per curvature ripetute gt 150 mm gt 150 mm gt 150 mm gt 150 mm gt 150 mm Forza di tiro massima am 100N 100N 100N 100N 100N messa 76 kg km 67 kg km 67 kg km 73 kg km 117 kg km Resistenza all incendio resistente alla resistente alla infiammabile resistente alla infiammabile fiamma se fiamma se fiamma se condo VDE condo VDE condo VDE 0472 T804 0472 T804 0472 T804 tipo di prova tipo di prova C tipo di prova B Resistenza all olio resistente con resistente con resistente con buona resi resistente con limitazioni a limitazioni a limitazioni a stenza a grassi limitazioni a grassi e oli mi grassi e oli mi grassi e oli mi e
46. 21 Connettore di bus numero di ordinazione 6ES7 972 0B 40 Montaggio del cavo di bus Collegare il cavo di bus al connettore di bus con numero di ordinazione 6ES7 972 0B 40 nel modo seguente 1 Togliere l isolamento dal cavo di bus in base alla figura 4 22 con il FastConnect Stripping Tool per la tabella delle quote vedere il lato posteriore dell attrezzo 6XV1 830 0EH10 SIEMENS La lV Figura 4 22 Lunghezza sulla quale togliere l isolamento per il connettore di bus 6ES7 972 0B 40 2 Aprire il contenitore del connettore di bus allentando le viti del contenitore e to gliendo il coperchio 3 Inserire i conduttori verdi e rossi nella morsettiera a vite in base alla figura 4 22 Durante questa operazione fare attenzione che vengano allacciati sempre gli stessi conduttori agli stessi allacciamenti A o B p es allacciamento A sempre con il filo verde e allacciamento B con il filo rosso Reti PROFIBUS SIMATIC NET 4 42 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 Premere la guaina del cavo tra i due inviti di fissaggio In questo modo il cavo viene fissato 5 Serrare i conduttori verdi e quelli rossi nel morsetto a vite Collegamento del cavo di bus per la prima e l ultima stazione sul bus q Interruttore ON resistenza termi nale attivata Lo schermo del cavo deve appoggiare completamente sul
47. 33 Dati tecnici 5 16 sfilare 4 46 Definizione 5 15 Connettore di bus 6ES7 972 0B 10 PROFIBUS terminator Disegno in scala F 6 Aspetto 4 37 PROFIBUS PA Guida per la messa in fun Montaggio del cavo di bus 4 38 zione 3 Connettore di bus 6ES7 972 0BA30 Aspetto 4 40 4 42 Montaggio del cavo di bus 4 40 4 42 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Index 1 R Repeater RS 485 Allacciamento del cavo di bus 5 14 5 17 Aspetto 5 15 Funzionamento senza collegamento a terra Im aa el della resistenza terminale 5 6 Montaggio 5 9 Possibilit di configurazione 5 6 Repeater RS 485 Disegno in scala F 7 F 8 F 9 F 11F 12 Repeater RS 485 Allacciamento della ten sione di alimentazione 5 13 Repeater RS 485 Aspetto 5 2 Assegnazione dei pin del connettore fem mina PGIOP 5 4 Dati tecnici 5 4 Definizione 5 2 Impiego 5 2 Regole Index 2 Resistenza terminale Connettore di bus 4 46 Repeater RS 485 5 6 RS 485 Repeater Disegno in scala F 5 Schema elettrico 5 5 S Schema elettrico RS 485 Repeater 5 5 Sicurezza intrinseca 2 23 Sovratensioni Definizione B 2 T Tensioni di disturbo Provvedimenti Tipo di protezione da scintille 2 23 Trattamento dello schermo per lo schermaggio di cavi C 9 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000
48. 35 8 Appendix 8 5 SIMATIC NET Support and Training 8 5 SIMATIC NET Support and Training SIMATIC Training Centers We offer courses designed to enable you to familiarize yourself with the SIMATIC S7 automation system Please contact your regional Training Center or the Central Training Center in 90327 Nuremberg Germany Internet E Mail http www ad siemens de training AD Training nbgm siemens de SIMATIC Customer Support Hotline Available worldwide 24 hours a day t N rnberg Johnson City x Singapur Nuremberg N rnberg SIMATIC BASIC Hotline Local time Mo Fr 8 00 to 18 00 Telephone 49 911 895 7000 Fax 49 911 895 7002 Fax E Mail simatic support E Mail nbgm siemens de Johnson City SIMATIC BASIC Hotline Local time Mo Fr 8 00 to 17 00 Telephone 1 423 461 2522 1 423 461 2231 simatic hotline sea siemens com SIMATIC Premium Hotline rates charged only with SIMATIC Card Time Mo Fr 0 00 to 24 00 Telephone 49 911 895 7777 Fax 49 911 895 7001 36 Singapore Singapur SIMATIC BASIC Hotline Local time Mo Fr 8 30 to 17 30 Telephone 65 740 7000 Fax 65 740 7001 E Mail simatic hotline sae siemens com sg Version 1 1 8 00 8 Appendix 8 5 SIMATIC NET Support and Training SIMATIC Customer Support On line Services The SIMATIC Customer Support offers you comprehensive additional information about SIMATIC products with its on line services
49. 4 mm 20 C 60 C 20 C 60 C 20 C 60 C gt 60 mm gt 160 mm M 02Y ST CH 1x2x0 35 100V Polimero nero 10 3 0 5 mm 40 C 80 C 40 C 80 C 10 C 50 C gt 108 mm gt 216 mm 100 N 100 N 150 N 100 N 74 kg km 56 kg km 67 kg km 103 kg km 109 kg km resistente alla fiamma se condo VDE 0472 T804 tipo di prova B buona resi stenza a grassi e oli minerali resistente alla fiamma se condo VDE 0472 T804 tipo di prova B resistente con limitazioni a grassi e oli mi nerali resistente alla fiamma se condo VDE 0472 T804 tipo di prova B buona resi stenza a grassi e oli minerali resistente alla fiamma se condo VDE 0472 T804 tipo di prova B buona resi stenza a grassi e oli minerali resistente alla fiamma se condo VDE 0472 T804 tipo di prova C resistenza molto buona a grassi e oli mi nerali Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 5 Componenti passivi per reti RS 485 1 Propriet elettriche 20 C prove secondo DIN 47250 parte 4 o DIN VDE 0472 2 Cavi da trascinamento adatti alle seguenti esigenze min 4 milioni di cicli di curvatura con il raggio di curvatura specificato e un accelerazione di max 4 m s Diametro esterno gt 8 mm i connettori di bus possono essere allacciati solo dopo aver rimosso la guaina esterna Non adatto per l allacciamento al connettore di bus 6ES7 972 0BA30 0XA0 Lungh
50. 5 14 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 5 7 PROFIBUS Terminator Che cos un PROFIBUS Terminator Il PROFIBUS Terminator forma una terminazione attiva del bus Il vantaggio so stanziale consiste nel fatto che i nodi di bus possono essere disattivati scollegati o sostituiti senza compromettere il trasferimento dei dati Ci vale in particolare per nodi di bus posti sull estremita del cavo di bus ai quali finora dovevano essere atti vate e alimentate resistente terminali II PROFIBUS Terminator pu essere mon tato su una guida profilata a norma Numero di ordinazione 6ES7 972 0DA00 0AA0 Struttura del PROFIBUS Terminator La tabella 5 4 illustra la struttura del PROFIBUS Terminator Tabella 5 4 Struttura del PROFIBUS Terminator Struttura del PROFIBUS Terminator N Funzione Tensione di alimentazione LED 24 V Allacciamento per tensione di alimentazione DC 24 V Allacciamento PROFIBUS Fascetta di schermatura per il collegamento a terra della maglia di schermatura e per lo scarico di tiro del cavo di bus SIEMENS PROFIBUS TERMINATOR N Ba R M PE AIB KL OOO OO pa T D DI A 6ES7 972 0DA00 0AA0 X 2 3 4 5 Vite per collegamento a terra
51. 5 Mbit s e 3 Mbit s 12 Mbit s e un cavo di derivazione lungo 1 5 m con un connettore Sub D a 9 poli per lal lacciamento diretto ad un terminale di dati Il connettore Sub D viene innestato sul connettore femmina Sub D del terminale di dati e collegato a vite su un lato per la sicurezza meccanica Il bus terminal 12M necessita dal terminale di dati di una corrente di 90 mA con una tensione di alimentazione di 5 V tra i pin 5 M5 e 6 P5 del connettore Sub D Ad un segmento possono essere allacciati al massimo 32 BT12M Se al seg mento di bus sono allacciati altri nodi di bus come p es repeater questi riducono il numero massimo allacciabile di BT12M 9 6k 1 5M a 3M 12M Termination off PE Ai Bi A2 B2 PE Figura 4 30 Elementi di comando Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 53 Componenti passivi per reti RS 485 Terminazione del cavo 4 54 Attivare la terminazione sul primo e l ultimo nodo sul segmento di bus Se la termi nazione viene attivata terminazione on viene interrotto il collegamento tra il seg mento in arrivo A1 B1 e quello in partenza A2 B2 Il vantaggio che con resi stenze terminali dei bus attivate in modo errato non pi possibile accedere alle stazioni che si trovano dopo il bus terminal In questo modo possibile assicurare che per un segmento messo in funzione non siano attivate resistenze terminali di bus che non si trovano all
52. 54 725 61 and 725 71 Select a site to install the module so that the climatic limit values listed in the technical specifications are not exceeded The device emits infrared light in the non visible range According to the currently valid regulations the PROFIBUS ILM is included in the class of devices subject to the regulations covering laser protection IEC 60 825 1 although the device does not include laser equipment The emitted infrared power is below the limit values of laser protection class 1 LASER CLASS 1 27 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 7 2 General Notes on Installation and Startup First select the network topology suitable for your system You can then install and start up the PROFIBUS ILM step by step as shown below v VA Check the area for suitable sites where you can install the modules Make mounting brackets suitable for the sites you have chosen Chapter 8 describes an example of a general purpose support consisting of two identical mounting brackets that are easy to make Remove the four cover screws and disconnect the 20 pin ribbon cable from the basic module and then remove the top panel of the PROFIBUS ILM Caution Disconnect the cable by pulling out the connector do not pull the cable itself Do not touch the electronics module in the top panel Do not loosen the screws securing the electronics module Mount the PROFIBUS ILM on the support
53. 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS 2 5 2 Passaggio a PROFIBUS PA Accoppiamento del bus DP PA L accoppiamento del bus DP PA l elemento di collegamento tra PROFIBUS DP e PROFIBUS PA Esso collega in questo modo i sistemi di controllo processo alle apparecchiature da campo dell automazione di processo PA L accoppiamento del bus DP PA composto dalle seguenti unit e Accoppiatore DP PA Ex i 6ES7 157 0ADx0 0XA0 e Accoppiatore DP PA 6ES7 157 0ACx0 0XA0 e DP PA Link IM 157 6ES7 157 0AA80 0XA0 Per la realizzazione del DP PA Link con funzionamento di ridondanza sono inoltre necessari e Modulo di bus BM IM 157 per 2 x IM 157 6ES7 195 7HE80 0XA0 e Modulo di bus BM DP accoppiatore PA per 1 accoppiatore DP PA 6ES7 195 7HF80 0XA0 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 21 Topologie delle reti SIMATIC NET PROFIBUS 2 5 3 Accoppiatore DP PA La seguente figura 2 15 illustra il collegamento dell accoppiatore DP PA nel si stema Programming Operating and Monitoring SIMATIC PCS 7 oppure altro strumento per la parametrizza 5 zione Livello di gestione Industrial Ethernet PDM oppure altro strumento per la parametrizzazione Livello di cellaMaster DP ET200X Accoppiatore DP PA Livello di campo Area protetta da esplosioni RI n A gt EX Figura 2 15 Collegamento
54. 9 9 e CP443 5 9 9 9 Impiego in PG con interfaccia MPI 9 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 33 Componenti passivi per reti RS 485 Tabella 4 6 Struttura e settore di impiego dei connettori di bus IP 20 seguito Numero di ordinazione Impiego in PG con e CP 5412 A2 CP 5411 CP 5511 CP 5611 CP 5613 14 6ES7 972 0BA11 0X AO 6ES7 972 0BB11 0X AO 6ES7 972 0BA40 0XA0 6ES7 6GK1 6ES7 972 0BB40 0XA0 OBA30 0XA0 500 0EA02 COCO ET 200B ET 200L ET 200M ET 200S ET 200U OOOO PG 720 720C PG 730 PG 740 PG 750 PG 760 e Repeater e OP e OLM oo O 0000000 00000 O 0000000 00000 OOO 000000 Impiego in SI NUMERIK 840 C e 805 SM e IM 328N e IM 329N oo Impiego in NC 840 De FM NC SIMODRIVE 611 MCU e CP 342 5 Impiego in TI 505 e T1505 FIM e T1505 PRO FIBUS DP e RBC 4 34 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Dati tecnici La seguente tabella riporta i dati tecnici dei diversi connettori di bus Tabella 4 7 Dati tecnici dei connettori di bus in IP 20 Numero di ordina zione 6ES7 972 OBA11 0XA0 0BB11 0XA0 6ES7 972 OBA40 0XA0 OBB40 0XA0 6ES7 972 OBA30 0XA0 6GK1 500 OEA02 Connettore femmina OBA11 no OBA40 no no no PG 0BB11 si OBB40 si Velocita massima d
55. 9 z Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 4 Collegamento del cavo di bus al connettore di bus 4 4 1 Collegamento del cavo di bus al connettore di bus 6ES7 972 0B 11 Aspetto 6ES7 972 0B 11 La figura 4 15 illustra il connettore di bus con il numero di ordinazione 6ES7 972 0B 11 Viti per il fissaggio E SIEMENS 2 sulla stazione A Connettore D Sub a El 9 poli per il collega mento alla stazione Presa PG solo per P 6ES7 972 0BB11 0XA0 T Guide per cavo di bus PROFIBUS Interruttore per Viti del contenitore resistenza terminale Figura 4 15 Connettore di bus numero di ordinazione 6ES7 972 0B 11 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 37 Componenti passivi per reti RS 485 Montaggio del cavo di bus Collegare il cavo di bus al connettore di bus con numero di ordinazione 6ES7 972 0B 11 nel modo seguente 1 Togliere l isolamento dal cavo di bus in base alla figura 4 16 utilizzando il FastConnect Stripping Tool per la tabella delle quote vedere il lato posteriore dell attrezzo 6XV1 830 0EH10 6XV1 830 3FH10 7 9 9 7 9 9 Figura 4 16 Lunghezza sulla quale togliere l isolamento per il connettore di bus 6ES7 972
56. A conduttore verde Allacciamento B conduttore rosso Avvertenza Avvertenze per bus terminal 12 M Il bus terminal 12 M pu essere innestato solo su un interfaccia senza tensione Sulle estremit del segmento il cavo PROFIBUS pu essere allacciato solo alla coppia di morsetti A1 B1 morsetti A2 B2 vengono scollegati attivando la termi nazione del cavo del bus Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 57 Componenti passivi per reti RS 485 4 7 5 Montaggio sulla lamiera dell ar madio con viti di fissaggio Misure per il collegamento a terra Se il bus terminal viene montato su una guida ad U vedere figura 4 33 la fascetta di schermatura deve essere collegata alla guida ad U su un ampia superficie e a bassa resistenza di contatto tramite una molla interna Per il collegamento tra gli schermi del cavo e la terra locale di conseguenza sufficiente un collegamento possibilmente corto tra la guida ad U e la terra locale Fissaggio a parete con viti di fissaggio MADE IN GERMANY Bus terminate N n AB f out 8 e Punto di collegamento dello schermo Guida di terra Figura 4 33 Possibilit di montaggio e collegamento a terra dei bus terminal 4 58 MADE IN GERMANY B Bus terminated
57. Edizione 2 05 2000 3 31 Progettazione di reti Avvertenza Poich la formula di calcolo tiene in considerazione i tempi di transito di tutti i cavi FO e RS 485 nella finestra Opzioni gt Cavi la casella di controllo Considera configurazione cavi non deve essere attivata Parametri del bus 182614 as iso A na iS os qd T qd Figura 3 7 Finestra Parametri del bus definiti dall utente in STEP 7 V5 0 Reti PROFIBUS SIMATIC NET 3 32 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 4 1 Componenti passivi per reti RS 485 4 1 Cavi SIMATIC NET PROFIBUS Cavi PROFIBUS I cavi SIMATIC NET PROFIBUS sono disponibili in diverse versioni permettendo cos un adattamento ottimale ai diversi settori di impiego Tutte le specificazioni relative alle lunghezze dei segmenti e alle velocit di tra smissione si riferiscono esclusivamente a questi cavi e possono essere garantite solo per essi Istruzioni di installazione per cavi di bus RS 485 I cavi di bus sono soggetti a danneggiamenti meccanici Le istruzioni per un instal lazione corretta dei cavi di bus sono riportante nell appendice C Per facilitare la determinazione della lunghezza i cavi sono provvisti di una marca tura in metri Panoramica La tabella 4 1 riporta una panoramica dei cavi di bus per PROFIBUS e delle loro pr
58. FO duplex possono essere allacciati sia terminali di dati sia segmenti di bus elettrici A seconda delle esigenze di distanza possono essere realizzati cavi duplex con fibre ottiche di plastica PCF o di vetro solo OLM Reti PROFIBUS SIMATIC NET 2 8 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Sorveglianza della linea FO Con l aiuto della funzione eco viene garantita una sorveglianza della linea FO tra mite i relativi OLM allacciati Un interruzione della linea viene segnalata da indica tori LED e dall intervento di un contatto di segnalazione Anche se viene a mancare solo una direzione di trasmissione la segmentazione accoppiata con la funzione di sorveglianza comporta una separazione sicura degli OLM dall accoppiatore a stella Il resto della rete continua a funzionare senza di sturbi Struttura combinata L accoppiatore a stella pu essere configurato in modo combinato sia con OLM P OLM G sia con OLM G 1300 sul lato RS 485 Anelli ottici ridondanti con OLM Gli anelli ottici ridondanti rappresentato una forma speciale della topologia lineare Chiudendo la linea ottica in un anello viene raggiunta una maggiore sicurezza di funzionamento della rete S7 400 a 57 400 PG dad Sey ET 200M sevens
59. ILM Foro di montaggio 2 Foro di montaggio 1 Figura F 15 Quote per foratura per il fissaggio di PROFIBUS ILM su una piastra di montaggio Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 F 11 DISEGNI IN SCALA F 8 Disegni in scala dell Optical Link Module OLM SIUUMII I N I SANI ELL Figura F 16 Optical Link Module OLM su una guida profilata a norma con altezza di 15 mm lt 40 137 SS him Das amp ca 150 Reti PROFIBUS SIMATIC NET F 12 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA Verriegelungs schieber Figura F 17 Montaggio dell Optical Link Module OLM su una guida profilata a norma con altezza di 7 5 mm 3 m 40 6 mm 81 2 mm 3 mm Figura F 18 Montaggio dell Optical Link Module OLM su una piastra di montaggio Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 F 13 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 ISTRUZIONI PER L USO ILM OLM OBT Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 G G 1 ISTRUZIONI PER L USO ILM OLM OBT G 2 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 SIEMENS
60. LED BFOC 2 5 BFOC 2 5 A ite socket socket indicators measuring sockets and the individual ports 1 BFOC stands for Bayonett Fiber Optic Connector This connector type is functionally compatible with ST connectors ST is a registered trademark of AT amp T Version 1 1 8 00 5 1 Introduction Table 1 shows the different methods for connecting the modules and the maximum optical ranges of each port OLM P11 P 12 G11 G12 G11 1300 G12 1300 G12 EEC Number of ports electrical 1 optical 1 2 1 2 1 Fiber types Plastic optical fibers 980 1000 um 80m 80m PCF optical fibers 200 230 um 400 m 400 m Quartz glass optical fibers 10 125 um 15 km 15 km 50 125 um 3000 m 3000 m 10 km 10 km 62 5 125 um 3000 m 3000 m 10 km 10 km Table 1 Number of electrical and optical ports per module fiber types which can be used as well as the maximum possible optical fiber distances between two modules See Technical Data p 31 for more details about ambient conditions PCF stands for Polymer Cladded Fiber and is the same as HCS HCSisa registered trademark of Ensign Bickford Optics Company a4 _ One measuring output is available for each optical port where the optical input level can be measured using a conventional voltmeter Different OLM malfunction reports are provided as an accumulative signal via a signaling contact relay wi
61. NET PCF vengono forniti con una treccia in kevlar come attrezzo di inserimento Fissare il dispositivo di tiro solo sull attrezzo di inserimento Nell appendice D sono riportate istruzioni dettagliate per l utilizzo dell attrezzo di inserimento Applicazione dello scarico di tiro Nonostante i connettori BFOC dispongano di uno scarico di tiro e di una guaina di protezione antipiega si consiglia di proteggere il cavo contro sollecitazioni mecca niche con uno scarico di tiro supplementare possibilmente in prossimit dell appa recchio allacciato Pianificazione di riserve di attenuazione Durante l installazione dei cavi su grandi distanze si consiglia di progettare nel bi lancio di attenuazione uno o pi collegamenti di sdoppiamento per i lavori di ripara zione Immunit a disturbi elettromagnetici I cavi FO sono immuni a disturbi elettromagnetici La posa dei cavi in un canale insieme ad altri cavi p es cavi di alimentazione 230 V 380 V pu quindi essere realizzata senza problemi In caso di posa in canali di cavi va tuttavia fatta atten zione che inserendo altri cavi non venga superata la sollecitazione massima am messa dei cavi FO Reti PROFIBUS SIMATIC NET C 24 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Allacciamento dei cavi in fibra ottica PROFIBUS L allacciamento dei diversi cavi in fibra ottica PROFIBUS a componenti di bus ottici OLM OBT e apparecchi con interfacce
62. Optical 5 6 Busterminal OBT C79000 G8972 C122 02 Messa in funzione Avvertenza Se la fibra sporge dalla superficie del connetore quest ultimo non deve essere inserito nel connettore femmina Sussiste pericolo di distruzione dei componenti ottici Allacciamento del cavo elettrico RS 485 Il canale CH1 serve per l allacciamento di un singolo terminale PROFIBUS DP CH1 concepito come interfaccia elettrica RS485 con connettore femmina SUB D a 9 poli La lunghzza massima del cavo tra OBT e terminale di 100m Poich si tratta di un collegamento punto a punto su entrambe le estremit del cavo nel con nettore PROFIBUS necessario attivare le resistenze terminali Come cavo di bus RS 485 utilizzare solo cavi a due conduttori SIMATIC NET schermati e attorcigliati per PROFIBUS Non allacciare cavi di bus RS 485 che si trovano completamente o in parte al di fuori dell edificio In caso contrario eventuali scariche di fulmini potrebbero compor tare la distruzione dei PROFIBUS OBT Eseguire collegamenti di bus che escono dall edificio possibilmente con cavi a fibre ottiche Se sull altra estremit del cavo non allacciato nessun nodo scollegare il cavo di bus RS 485 dall OBT Gli accoppiamenti possono comportare la distruzione del PROFIBUS PROFIBUS Optical Busterminal OBT 5 7 C79000 G8972 C1 22 02 PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Rimedi in caso di disturbi di funziona ment
63. PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 7 1 Componenti passivi per reti ottiche 7 1 Cavo in fibra ottica Cavo in fibra ottica FO Vantaggi Nei cavi in fibra ottica FO la trasmissione dei dati viene eseguita tramite modula zione delle onde elettromagnetiche nel campo luminoso visibile e invisibile Come materiale vengono impiegate fibre di plastica materiale sintetico e vetro di elevata qualit Qui di seguito vengono descritti i cavi FO previsti da SIMATIC NET per PROFI BUS diversi tipi di cavi FO permettono soluzioni adatte alle condizioni d esercizio e ambientali per il collegamento dei componenti Rispetto ai cavi elettrici i cavi FO presentano i seguenti vantaggi e Separazione galvanica dei nodi e dei segmenti e Senza correnti equipotenziali e Nessuna influenza della linea di trasmissione dovuta a disturbi elettromagnetici esterni e Nessun elemento di protezione antifulmine necessario e Nessuna diffusione di disturbi lungo la linea di trasmissione e Pesoridotto e A seconda del tipo di fibra possono essere realizzate linee di alcuni chilometri anche ad elevate velocit di trasmissione e Le lunghezze massime ammesse della linea non dipendono dalla velocit di trasmissione Collegamento punto a punto 7 2 Con i cavi FO tecnologicamente possibile realizzare solo collegamenti punto a punto ci significa che un trasmettitore collegato ad un solo ricevitore Per una
64. RO INI sd stems A seers tens 1 B P T m c Tracciato 2 l Resistenza terminale attivata 1 cavo in fibra ottica 3 Cavo di connessione PROFIBUS 830 1T 2 cavo di bus PROFIBUS 4 Cavo di connessione PROFIBUS 830 2 Figura 2 5 Struttura della rete con topologia ottica ridondante a due fibre Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 9 Topologie delle reti SIMATIC NET PROFIBUS L interruzione di un cavo FO tra due moduli viene identificata dai moduli stessi e la configurazione della rete viene modificata in una linea ottica L intera rete rimane a disposizione Se un modulo si guasta sono disaccoppiati disturbati dall anello solo i terminali di dati o i segmenti elettrici allacciati a questo modulo il resto della rete rimane com pletamente in funzione come linea La segnalazione di guasto viene indicata dai LED dei moduli interessati e dai loro contatti di segnalazione Dopo la soppressione del guasto i moduli interessati eliminano automaticamente la segmentazione La linea riforma un anello Avvertenza Per aumentare la sicurezza di funzionamento i cavi duplex per entrambe le dire zioni nell anello devono essere installati su due tracciati separati Reti PROFIBUS SIMATIC NET 2 10 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Tecnica alternativa di cablaggio Se nella pratica risulta una lunghezza eccessiva della
65. SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C5 Installazione dei cavi di bus Installazione separata dei cavi di bus Per evitare danni involontari dei cavi di bus essi devono essere installati in modo visibilmente separato da tutte le altre linee e cavi In combinazione con le misure per migliorare le propriet di EMC si consiglia una posa dei cavi di bus in canali di cavi separati o in tubi di conduzione metallici Grazie a questo tipo di misure viene inoltre semplificata la localizzazione di un cavo difettoso Reti PROFIBUS SIMATIC NET C 6 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus C 4 Compatibilit elettromagnetica dei cavi di bus Compatibilit elettromagnetica EMC La compatibilit elettromagnetica EMC comprende tutti i quesiti degli effetti di ricezione ed emissione elettrici magnetici ed elettromagnetici Per evitare effetti di disturbo negli impianti elettrici necessario limitarli ad un de terminato valore Tra le misure di limitazione quelle pi rilevanti sono la struttura costruttiva e l allacciamento corretto del cavo di bus componenti e i cavi di bus per SIMATIC NET PROFIBUS rispondono ai requisiti degli standard europei per quel che riguarda le apparecchiature per l impiego nel settore industriale Questo requisito documentato dal marchio CE Avvertenza Il rispetto dei valori limite prescritti pu essere garantito solo impiegando compo nenti SIMATIC NE
66. Setting Up 4 3 Setting compatibility operating mode and transmitting power Operating mode Redundant optical ring 01 na DI ns CH 3 CHS is activated in this operating mode if S3 and S4 are in Position 1 FCH 2 CH2 is activated in this operating mode if S1 and S2 are in Position 1 l C mi C CE Note This operating mode must always be set at both of the optical ports of a module 4 3 3 Reducing the optical transmitting power on the OLM P11 and OLM P12 Attention The following details only apply for the S7 default position S7 0 The OLM P11 and OLM P12 have a high level of optical transmitting power Optical overloading may result if these modules are connected with non OLM devices using plastic optical fiber cables particularly if short cable lengths are used In this case the optical transmitting power can be reduced The DIL switch S5 is used to set the transmitting power of CH2 The DIL switch S6 is used to set the transmitting power of CH3 S6 does not have a function on the OLM P11 o gt Leave S6 in Position 1 default if the optical fiber link to CH3 functions correctly in this position h Leave S5 in Position 1 default if the optical fiber link to CH2 functions correctly in this position al Oo Al S6 E CH 3 Switch S6 to Position 0 reduced if overloading is detected at a non OLM devic
67. U di 35 mm con un al tezza di 15 mm secondo DIN EN 50 022 35 x 15 o direttamente su una base piana e Scegliere la posizione di montaggio in modo da rispettare i valori limite climatici riportati nei dati tecnici e Lasciare spazio sufficiente per l allacciamento dei cavi di bus e della tensione di alimentazione e Montare i moduli solo su una guida ad U o una piastra di montaggio con messa a terra a bassa resistenza e a bassa induttanza Per il fissaggio su una piastra di montaggio necessario installare un cavo possibilmente corto dal morsetto di terra dell OBT alla possibilit di terra pi vicina Montaggio su una guida ad U e Agganciare il gancio superiore del modulo nella guida ad U e premere il lato inferiore come illustrato in Figura 5 1 sulla guida fino a quando scatta udibil mente e Lo smontaggio viene eseguito tirando la levetta di bloccaggio verso il basso Figura 5 1 Montaggio di un modulo su una guida ad U standard PROFIBUS Optical Busterminal OBT 5 3 C79000 G8972 C 122 02 Messa in funzione Installazione su una piastra di montaggio PROFIBUS OBT sono previsti con due fori di passaggio Questi fori permettono un montaggio su una qualsiasi base piana per esempio su una piastra di montag gio dell armadio di comando e Eseguire due fori sulla piastra di montaggio in corrispondenza dello schema di foratura della figura 5 2 e Fissare il modulo con le viti della macchina p es M3 x 75 e M
68. V Corrente assorbita max 5 MA max 5 MA Zul Condizioni ambientali ammesse Temperatura d esercizio Temperatura di trasporto di magazzinaggio Umidit relativa da 0 C a 60 C da 25 C a 80 C max 75 a 25 C da 0 C a 60 C da 25 C a 80 C max 75 a 25 C Esecuzione costruttiva Dimensioni LxAxP 72 7x16x34 61 7x16x35 Peso ca 50 g ca 50 g Classe di protezione IP20 IP20 Allacciabili cavi PROFIBUS con 8 0 5 mm 8 0 5 mm diametro Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 27 Componenti passivi per reti RS 485 Funzione di scollegamento La funzione di scollegamento provvede a disattivare il cavo che parte dal bus con resistenza terminale attivata Se la resistenza terminale viene involontariamente attivata al centro del cavo di bus questo errore viene immediatamente identificato e quindi localizzato dal nodo non pi raggiungibile Scollegamento di una stazione Il connettore di bus permette di scollegare un nodo di bus senza interrompere il traffico di dati sul bus Non ammesso sfilare il connettore di bus con la resistenza terminale attivata sulle estremit del cavo di bus in quando comporta disturbi al bus Connettore di bus con connettore femmina PG Si raccomanda di inserire in ogni segmento di bus almeno un connettore di bus con connettore femmina PG In questo modo si facilita la messa in
69. accoppiabile nella fibra um Pa min dBm Sensibilit del ricevitore Pe min dBm Valore massimo ammesso di attenuazione Amax Pa min Pe min dB Riserve di sistema Amax Alinea dB Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 oo N pare Progettazione di reti 3 3 3 22 Tempo di transito del telegramma Il tempo di reazione del sistema di una rete PROFIBUS dipende dai seguenti fattori e configurazione del sistema sistema monomaster o multimaster e tempo di reazione massimo dei singoli nodi di bus e quantit di dati da trasmettere e configurazione del bus topologia lunghezza del cavo componenti attivi della rete L adattamento dei parametri di bus alla relativa rete PROFIBUS progettazione viene eseguito con un software di progettazione come p es COM PROFIBUS o STEP 7 Con i Optical Link Modul possibile realizzare reti PROFIBUS di grandi dimen sioni Essi permettono il funzionamento di linee molto lunghe di cavi in fibra ottica e possono essere collegati in cascata Ogni attraversamento di OLM comporta un ritardo A causa dei ritardi del telegramma dovuti ai cavi e ai componenti della rete nonch ai dispositivi di controllo nei componenti della rete durante la progettazione ne cessario adattare i parametri della rete PROFIBUS tempo di slot all estensione della rete alla topologia della rete e alla velocita di trasmissione Reti PROFIBUS SIMATIC NET 6GK1
70. ambient conditions Ambient temperature 0 C to 60 C IEC 68 2 1 IEC 68 2 2 20 C to 60 C at OLM G12 EEC IEC 68 2 1 IEC 68 2 2 Storage temperature 40 C to 70 C IEC 68 2 14 Relative humidity lt 95 non condensing IEC 68 2 30 100 condensing at OLM G12 EEC IEC 68 2 30 Mechanical ambient conditions Vibration during operation 10 to 58 Hz 0 075 mm displacement 58 to 150 Hz 10 m s 1 g acceleration IEC 68 2 6 Vibration during transport 5 to 9 Hz 3 5 mm displacement 9 to 500 Hz 10 m s 1 g acceleration Protection class IP 40 Dimensions W x H x D 39 5 x 110 x 73 2 mm Housing material Die cast zinc Weight approx 500 g 1 The OLM G12 can also be supplied in a special design for more severe environmental conditions This variant is designated the OLM G12 EEC The DIL switches on the OLM G12 EEC may also only be operated at ambient temperatures between 0 C and 60 C 2 The specified distance allowed between two OLMs must not be exceeded regardeless of the optical power budget The module does not contain any silicon 32 Version 1 1 8 00 8 Appendix 8 1 CE Designation 8 Appendix 8 1 CE Designation Product Designation SIMATIC NET OLM P11 6GK1502 2CA00 OLM P12 6GK1502 3CA00 OLM G11 6GK1502 2CB00 OLM G12 6GK1502 3CB00 OLM G11 1300 OLM G12 1300 OLM G12 EEC 6GK1502 2CC00 6GK1502 3CC00 6GK1502 3CD
71. and without twisting the connector and screw it on tightly Proceed in the reverse order when removing a device from the network Ensure that the bus segment connected to the RS 485 interface is terminated at both ends Only use a connecting cable which is terminated at both ends to connect a single device UN Observe the following safety notice Do not connect any bus lines which have been partially or totally laid outside of buildings Otherwise lightning strikes in the vicinity of the cable could destroy the module Use optical fiber lines for bus connections which lead out of a building 22 Version 1 1 8 00 4 Setting Up 4 4 Installation 4 4 4 Connecting the power supply L1 24V D D M L D D L2 24 V D Fig 10 Operating voltage supply assignment of 5 pin terminal block The terminal block can be removed from the device to connect the lines The module should only be supplied with a regulated safety extra low voltage in accordance with IEC 950 EN 60 950 VDE 0805 with a maximum of 32 V typical 24 V The power source must comply with the regulations of the NEC Class 2 in accordance with UL CSA approval It can be fed in using the 5 pin terminal block on the top of the module To increase operational safety the module can be redundantly supplied via the terminals L2 24 V and M L In the event of a failure of the regular power supply the module switches automatica
72. arrow pointing into a circle If the arrow on the orange cord points into the cable connect this cord to the transmitter The transmitter is identified by an arrow pointing out of a circle 1 Only the standard cable has this marking orange core with arrows the duplex cord does not have this marking Page 10 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors Cables Tools and Accessories SIMATIC NET PROFIBUS Plastic Fiber Optic standard cable I VYA4Y2P 980 1000 160A Robust round cable with two plastic FO cords violet PVC outer jacket and PA inner jacket without connectors for use indoors in meters 6XV1 821 0AH10 50 m ring 6XV1 821 0AN5O 100 m ring 6XV1 821 0AT10 SIMATIC NET PROFIBUS Plastic Fiber Optic duplex cord I VY2P 980 1000 150A Plastic FO cable with two cords PVC jacket without connectors for use in environments where it is subjected to little mechanical stress for example within a cubicle or in a laboratory 50 m Ring 6XV1 821 2AN50 SIMATIC NET PROFIBUS Plastic Fiber Optic Stripping Tool Set Cable knife for removing the outer jacket and buffer stripper round cutting pliers for removing the buffer of SIMATIC NET plastic fiber optic cables 6GK1 905 6PA10 SIMATIC NET PROFIBUS Plastic Fiber Optic Plastic Simplex Connector Polishing Kit 100 plastic simplex connectors and 5 polishing kits for assembling SIMATIC NET PROFIBUS plastic fiber op
73. assigned using the sup plied protective caps note an optical port which has not been assigned should be switched to the operating mode Line without optical fiber link monitoring to avoid a break in the fiber line from being signaled Extraneous ambient light can cause interference in the network especially under very bright conditions Optical components can be rendered useless if dust infiltrates them Please note the maximum length of the optical fiber line and the possible fiber types which are shown in Table 1 p 6 and in the Technical Data p 31 Version 1 1 8 00 4 Setting Up 4 4 Installation 4 4 2 Mounting the modules Fig 7 Mounting a module on a standard hat rail HH H EN BH ORANO BHf Gr ECE Toothed washer I 61 2 mm Tu E A E o c ze EY N 3 mm q 3 mm el e lol LJ Fig 8 Mounting a module on a mounting plate Version 1 1 8 00 The OLM modules can either be mounted on a 35 mm hat rail in accordance with DIN EN 50022 or directly on to a flat surface Install the device in a location where the climatic and mechanical limit values defined in the Technical Data can be complied with Ensure that there is sufficient room to connect the bus and power supply cabling Connect the optical fiber line before mounting the module This is easier than
74. autoestintore in caso di incendio e resistente con limitazioni a grassi e oli minerali e rivestito con una guaina di materiale non esente da alogeni Il cavo di bus concepito per l installazione fissa all interno di edifici cablaggio In house Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 7 Componenti passivi per reti RS 485 4 1 2 Conduttore interno in rame massiccio Figura 4 2 FC FRNC Cable cavo di bus con guaina esterna esente da alogeni Guaina esterna in FRNC Schermo a maglia in rame Foglio di schermatura in alluminio Protezione di isolamento in PE cellulato Principio di struttura del cavo di bus con guaina esterna esente da alogeni Cavo di bus con guaina esterna esente da alogeni 6XV1 830 0LH10 Propriet Impiego 4 8 Il cavo di bus con guaina esterna esente da alogeni 6XV1 830 0LH10 corrisponde alla specifica secondo EN 50170 tipo di cavo A con conduttori in rame massiccio AWG 22 La struttura del cavo permette l impiego delFastConnect FC Stripping Tool per lo spostamento rapido del cavo PROFIBUS vedere capitolo 4 2 3 Rispetto al cavo di bus standard il materiale della guaina esterna di questo cavo presenta le seguenti propriet e il materiale esente da alogeni e nessuna resistenza a radiazioni UV e il materiale della guaina esterna resistente alla fiamma Il cavo di bus con guaina esterna esente da alogeni particolarmente adatto
75. automa zione da sovratensioni Introduzione Le cause pi frequenti per guasti dell hardware sono tensioni provocate da e apertura e chiusura di interruttori nelle sotto stazioni elettriche e scariche atmosferiche o e scariche elettrostatiche In questo capitolo descritto come proteggere apparecchi allacciati ad cavo di bus PROFIBUS da sovratensioni Avvertenza Questo capitolo pu fornire solo istruzioni per la protezione da sovratensioni di componenti hardware su un cavo di bus PROFIBUS Una protezione integrale da sovratensioni garantita solo se l interno impianto di automazione e tutti gli edifici circostanti sono progettati con protezioni da sovraten sioni Ci riguarda soprattutto regole costruttive negli edifici gi nei progetti di cos truzione Per questo motivo se si intende ricevere informazioni riguardanti la protezione da sovratensioni raccomandiamo di rivolgersi al proprio consultente Siemens o ad una ditta specializzata per la protezione contro i fulmini Ulteriore documentazione B 2 Ulteriori informazioni dettagliate relative alla protezione da sovratensioni per im pianti di auotmazione con SIMATIC S7 sono riportate nei relativi manuali di si stema S7 300 11 S7 400 12 ET 200 9 Le soluzioni riportate in queste documentazioni sono basate sul concetto di aree di protezione antifulmine descritte nella norma IEC 1024 2 Protection against LEMP Reti PROFIBUS SIMATIC NET 6GK1970 5CA2
76. bus terminal RS 485 Connessione verso terminale di dati Velocit di trasmissione Interfaccia PG opzione Campo tensione di alimentazione Corrente assorbita Condizioni ambientali Temperatura d esercizio Temperatura di trasporto di magazzinaggio Umidit relativa Esecuzione costruttiva Dimensioni L x A x P inmm Peso compr cavo di derivazione 1 5 m 4 60 Connettore Sud D a 9 poli 9 6 fino a 1 500 kbit s Connettore femmina Sub D a 9 poli DC 4 75 fino a 5 25 V 5 mA da 0a55 C da 25a 70 C F secondo DIN 40040 da 15 a 95 a 25 C senza condensa RS 485 50 x 135 x 47 RS 485 PG 50 x 135 x 52 RS 485 RS 485 PG ca 310 g Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 7 7 Dati tecnici del bus terminal 12M Connessione verso terminale di dati Velocit di trasmissione Tensione di alimentazione Corrente assorbita Potenza dissipata complessiva Fattore capacitivo Compatibilit elettrimagnetica Emissione disturbi Classe valori limite Immunit ai disturbi sui cavi di segnale Immunit ai disturbi contro scariche statiche di elettricit Immunit ai disturbi contro irradiazioni alta frequenza Condizioni climatiche Temperatura d esercizio Temperatura di trasporto di magazzinaggio Umidit relativa Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Dati tecnici del bus terminal 12M Connettore Sud D a
77. busy for longer than the maximum permitted send time forwarding of the received signals is blocked until frames can be received again correctly or if no signal is received for one second The RS 485 bus segment is not monitored in the operating mode Electric port without segment monitoring Interference from the electrical segment affects the entire network Please observe the installation notes in 4 4 3 Connecting the electrical RS 485 bus lines p 22 Version 1 1 8 00 7 2 General Functions 2 2 Operating mode related functions The following functions are only available for the optical ports Whether the functions can be activated depends on the operating mode which has been set Please refer to the following chapters for details Line monitoring with echoes The modules enable the connected optical paths to be actively monitored for interruptions in the fiber line by means of the functions Send echo Monitor echo and Suppress echo Send echo A frame which is received by a module via any port is transmitted to all other ports If the receiving port is an optical port the module sends the frame back to the corresponding optical sender Monitor echo If a module sends a frame no echo to an optical port the module expects to receive an echo If the echo is not received after a predefined time an echo monitoring error is indicated by a red LED belonging to the port Suppress echo The relevant rec
78. con connettori di bus bus terminal o repea ter RS 485 Terminazione dei cavi 2 2 Ogni segmentodi bus deve essere chiuso su entrambe le estremit con impedenza caratteristica Questa terminazione del cavo integrata nel repeater RS 485 nei bus terminal negli ILM e nei connettori di bus e in caso di necessit pu essere attivata Per permettere che questa terminazione del cavo diventi attiva il relativo elemento di allacciamento deve essere alimentato Per i bus terminal e i connettori di bus l alimentazione viene effettuata dai terminali di dati allacciati per i repeater RS 485 gli ILM e i terminali dalla loro tensione di alimentazione La tecnica trasmissiva RS 485 permette l allacciamento di max 32 accoppiamenti di bus terminali di dati e repeater per ogni segmento di bus La lunghezza mas sima ammessa del cavo di un segmento dipende dalla velocit di trasmissione e dal cavo di bus impiegati Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Collegamento di segmenti tramite repeater RS 485 S7 400 S7 300 Grazie all impiego di repeater RS 485 possibile collegare segmenti tra loro II repeater RS 485 rinforza i segnali dei dati sui cavi di bus Il repeater RS 485 ne cessario se alla rete sono allacciati pi di 32 nodi oppure se viene superata la lun ghezza ammessa del segmento Tra due nodi possono essere impiegati max 9 re peater Possono
79. connecting it after the module has been installed Only mount the module on a low impedance and low induction grounded hat rail or base plate No other grounding measures are required Mounting on a hat rail Hang the top snap in hooks of the module into the hat rail and press the underside onto the rail as shown in Fig 7 until it audibly clicks in To remove the module pull down on the locking slide Mounting on a mounting plate The modules have three through holes This allow it to be mounted on any flat surface e g on the mounting plate of a switch cabinet Drill three holes in the mounting plate corresponding to the drilling template in Fig 8 Secure the modules with machine bolts e g M 3 x 40 Ensure that there is a reliable electrical connection between the module housing and the mounting plate Place toothed washers under the bolt heads to pierce the varnish 21 4 Setting Up 4 4 Installation 4 4 3 Connecting the electric RS 485 bus lines The modules are fitted with an RS 485 electrical port Ground 5 This is a 9 pin Sub D socket with a screw lock inside 9 n c Meta thread UNC 4 40 Br a RxD TxD P 3 The pin assignment complies with the PROFIBUS stan ee Ground 2 dard At Pin 6 there is a short circuit proof 5V output for 6 5V Output PE 1 supplying external pull up pull down resistors Shield As opposed to the 24V power supply and the casing ground potential the RS 485 bus lines Rx
80. custodia supple mentare Questo pu comportare un notevole aumento della temperatura all in terno Manenere una distanza sufficiente intorno ad un componente in modo che e la ventilazione dei componenti non venga impedita e pi componeti non si surriscaldino reciprocamente in modo non ammesso e rimanga spazio sufficiente per l installazione di cavi di collegamento e rimanga spazio sufficiente per lo smontaggio in caso di interventi di manuten zione e riparazione Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 E 3 Installazione di componenti di rete in un armadio Norme Avvertenza Indipendentemente dal grado di protezione della custodia le interfacce elettriche e ottiche sono sempre soggette a danneggiamento meccanico distruzione in seguito a scariche elettrostatiche in caso di contatto imbrattamento dovuto a polvere e liquidi Applicare di conseguenza sempre alle interfacce non utilizzate i cappucci parapol vere compresi nella foritura Rimuovere questi cappucci solo immediatamente prima del collegamento dei cavi delle interfacce EN 60529 1991 grado di protezione tramite custodia IP Code IEC 60529 1989 EN 60529 1989 Degrees of protection provided by enclosures IP Code Ulteriore documentazione E 4 Klingberg G Mahling W Schaltschrank und Geh use Klimatisierung in der Praxis mit EMV Heidelberg 1998 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2
81. degli OLM All interfac cia RS 485 pu essere allacciato un singolo terminale di dati oppure un segmento PROFIBUS completo con max 31 nodi OP 25 OP 25 ET 200M ET 200S N Connettore di bus Resistenza terminale attivata 1 cavo in fibra ottica 2 cavo di bus PROFIBUS 3 Cavo di connessione PROFIBUS 830 1T 4 Cavo di connessione PROFIBUS 830 2 Figura 2 3 Esempio di una topologia lineare con OLM Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 7 Topologie delle reti SIMATIC NET PROFIBUS Topologia a stella con OLM Diversi Optical Link Module vengono raggruppati in un accoppiatore a stella tramite un collegamento di bus delle interfacce RS 485 Questo collegamento RS per mette l allacciamento di altri terminali di dati fino a raggiungere un numero mas simo ammesso di 32 accoppiamenti del bus per ogni segmento S7 400 Punto a stella Resistenza terminale attivata 1 cavo in fibra ottica 2 cavo di bus PROFIBUS 4 Cavo di connessione PROFIBUS 830 2 Figura 2 4 Esempio di una tolopogia a stella con OLM Canali ottici Gli OLM sono collegati con l accoppiatore a stella tramite cavi FO duplex Agli OLM allacciati con cavi
82. dei cavi all interno di armadi Per l installazione dei cavi all interno di armadi necessario osservare quanto segue La distanza minima tra cavi di diverse categorie riportata nella tabella C 1 zu entnehmen Generalmente il pericolo di disturbi dovuti a diafonia viene ridotto pi i cavi sono distanti tra loro Gli incroci di diverse categorie devono essere eseguiti ad angolo retto linee possibilmente corte di installazione parallela Se non disponibile spazio sufficiente per mantenere una distanza gt 10 cm tra le singole categorie i cavi devono essere installati in canali di coduzione metal lici separati per categoria Questi canali possono essere disposti direttamente uno di fianco all altro canali di conduzione metallici devono essere collegati a vite al longherone del telaio o alle pareti dell armadio ogni 50 cm a bassa resi stenza e a bassa induttanza Gli schermi di tutti i cavi che escono dall armadio devono trovarsi il pi vicino possibile al punto di ingresso nel rivestimento dell armadio e collegate alla terra dell armadio su un ampia superficie e a bassa resistenza di contatto L installazione parallela di cavi provenienti dall esterno tra punto di ingresso dell armadio e punto di collegamento dello schermo e cavi che si trovano all in terno dell armadio deve essere assolutamente evitata anche per cavi della stessa categoria C 5 3 Installazione dei cavi all interno di edifici Per l in
83. della sicurezza intrinseca nei sistemi Feldbus relazione PTB W 53 Braunschweig marzo 1993 e PROFIBUS PA Guida per la messa in funzione Avvertenze per l impiego della tecnica IEC 1158 2 per PROFIBUS art numero 2 091 PROFIBUS Nutzerorganisation e V Haid und Neu StraBe 7 D 76131 Kar Isruhe Numeri di ordinazione numeri di ordinazione per le documentazioni SIEMENS sopraindicate sono ripor tati nei cataloghi SIMATIC NET Conumicazione industriale catalogo IK 10 e SIMATIC Sistemi di automazione SIMATICS7 M7 C7 Questi cataloghi nonch ulteriori informazioni e l offerta di corsi di formazione pos sono essere richiesti presso le relative filiali e societ regionali SIEMENS A Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 1 3 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 SIMATIC NET Supporto e training SIMATIC Trainings Center Per semplificare l introduzione al sistema di automazione SIMATIC S7 offrinamo corsi specializzati Rivolgersi al Trainings Center regionale o al Trainings Center centrale di D 90327 Norimberga Infoline Tel 0180 523 5611 48 Pfg min Fax 0180 523 5612 Internet http www ad siemens de training E mail AD Training nbgm siemens de SIMATIC Customer Support Hotline Raggiungibile da tutto il modo a qualsiasi ora we ne Cos E Johnson City Simatic Basic Hotline Norimberga Johnson City SI
84. delle reti SIMATIC NET PROFIBUS Settore d impiego La DP AS Interface Link 20 realizza un accoppiamento ad altra rete di piccole di mensioni ed economico tra PROFIBUS e AS Interface Per la DP AS Interface Link 20 non necessaria un alimentazione supplementare l alimentazione viene eseguita con il cavo dell AS Interface La messa in servizio del segmento AS Inter face possibile con PROFIBUS DP non in funzione La DP AS Interface Link 20 allo stesso tempo slave PROFIBUS DP secondo EN 50170 e master AS Interface e collega in modo semplice PROFIBUS DP al AS Interface La DP AS Interface Link 20 realizza l allacciamento del sistema per e master PROFIBUS DP p es CP 342 5 per S7 300 CP 443 5 Extended per S7 400 CP 5431 FMS DP o IM 308C per SIMATIC S5 CP 5412 A2 per PC o CP 5611 CP5511 per PC con software DP SOFTNET e altri sistemi con funzionalit master DP Collegamento in rete sovraordinato tramite PROFIBUS DP DP AS Interface Link 20 Moduli passivi Moduli attivi senza slave ASIC con slave ASIC e A A Sure ol 3 cm Pal Alimentazione AS i Aktor Sensor 0000 con slave ASIC ll Fi lt Cavo Diramazione AS i Figura 2 23 Esempio di configurazione per DP AS Interface Link 20 Reti PROFIBUS SIMATIC NET 2 32 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Tipo di funzionamento La DP AS Interface Link 20 permette ad un master DP di raggiu
85. deve essere impiegato come termi nazione del cavo permanente 3 1 1 Segmenti per velocit di trasmissione fino ad un massimo di 500 kbit s Velocit di trasmissione fino ad un massimo di 500 kbit s cavi SIMATIC NET PROFIBUS permettono di realizzare le seguenti lunghezze massime di segmento Tabella 3 1 Lunghezze di segmento realizzabili Lunghezza di segmento per il tipo di cavo aa di a FC Standard Cable FC Trailing Cable Velocit di Wasmis _ FG Robust Cable PROFIBUS Flexible Cable FC FRNC Cable PROFIBUS Festoon Cable FC Food Cable FC Underground Cable Cavo marino SIENOPYR FR 9 6 1000 m 900 m 19 2 1000 m 900 m 45 45 1000 m 900 m 93 75 1000 m 900 m 187 5 1000 m 700 m Il numero massimo ammesso di accoppiamenti di bus terminali di dati repeater OLM BT12 M su un segmento 32 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 3 Progettazione di reti Lunghezza dei cavi di derivazione Se il cavo di bus non viene montato direttamente sul connettore di bus p es in caso di utilizzo di un bus terminal PROFIBUS necessario osservare la lun ghezza massima possibile del cavo di derivazione La seguente tabella illustra le lunghezze massime ammesse per i cavi di deriva zione per ogni segmento di bus Tabella 3 2 Lunghezza dei cavi di derivazione per ogni segmento Velocit Lunghezza massima dei Numero dei nodi con
86. di connessione PG L assegnazione di contatto identica a quella riportata nella tabella 4 10 Figura 4 28 Bus terminal RS 485 con interfaccia PG integrata Avvertenza bus terminal RS 485 SIMATIC NET PROFIBUS sono adatti solo per velocit di trasmissione di lt 1 5 Mbit s Per velocit di trasmissione superiori deve essere impiegato il bus terminal 12M Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 51 Componenti passivi per reti RS 485 4 7 3 Struttura e tipo di funzionamento del bus terminal 12M Figura 4 29 Bus terminal 12M BT12M Reti PROFIBUS SIMATIC NET 4 52 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Bus terminal 12 M Il bus terminal 12M serve per l allacciamento di terminali di dati con interfaccia RS 485 al cavo di bus Esso comprende e 1 morsettiera con 6 allacciamenti per conduttori con sezioni lt 1 5 mm per l allacciamento di cavi di bus in arrivo e in partenza e se necessario di terra PE Protective Earth e fascette a vite per il contatto di schermatura e due interruttori interruttore a destra Termination per collegare l estremit di un segmento elettrico in arrivo A1 B1 all impedenza caratteristica interruttore in posi zione on Contemporaneamente viene interrotto il segmento elettrico in par tenza A2 B2 interruttore a sinistra per impostare il campo della velocit di trasmissione 9 6 kbit s 1
87. di base 2 Misurare la lunghezza di 3 Inserire l estremit del cavo dell attrezzo spellafili nella cavo da spellare disponen misurata nell attrezzo spella mano destra dolo sulla dima di misura Ri fili Il riscontro per la profon scontro con il dito indice della dit di inserimento l indice mano sinistra della mano sinistra ae 4 Serrare il cavo nell attrezzo 5 Girare l attrezzo di spella 6 Sfilare l attrezzo spellafili spellafili fino in fondo tura per togliere il rivesti chiuso dall estremit del mento in PVC ca 4 volte e cavo In caso di un risultato per il rivestimento in PUR o non soddisfacente sostituire PE ca 8 volte la lama dell attrezzo 7 resti del cavo rimangono 8 Sfilare il rivestimento di 9 Montare il cavo di bus Fa nell attrezzo Dopo lo sbloc protezione dai conduttori stConnect nel connettore caggio dell attrezzo i resti del cavo possono essere rimossi Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Cavo in arrivo A1 B1 Cavo in partenza A2 B2 Combinazione di resistenze con funzione di scollega mento 1 Aprire la vite dello scarico di tiro 4 Inserire il cavo in arrivo nel coperchio di contatto con la contrassegnatura A1 B1 os servare contrassegnatura dei colori Interruttore ON In caso di impiego del connet tore sull estremit di un seg mento l interruttore deve
88. di segmento A causa dell elevata resistenza del conduttore a basse velocit di trasmissione sono ammesse solo lunghezze di segmento leggermente ridotte vedere tabella 3 1 Per velocit di trasmissione gt 500 kbit s il cavo da trascinamento presenta gli stessi valori del cavo di bus standard Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 19 Componenti passivi per reti RS 485 Avvertenza In caso di allacciamento con morsetti a vite i conduttori a trefoli devono essere avvitati solo con l aiuto di capicorda 0 25 mm secondo DIN 46228 Utilizzare solo copicorda di materiale con propriet di contatto a stabilit permanente p es rame con superficie stagnata non alluminio Il connettore di bus 6ES7 972 0BA30 0XA0 non pu essere allacciato ai condut tori a trefoli Reti PROFIBUS SIMATIC NET 4 20 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Direttiva di montaggio Durante il montaggio il cavo deve essere avvolto dal tamburi in modo tangenziale e senza torsioni fare attenzione ai trattini longitudinali alle marcature e inserito nel carrello portacavi Il cavo deve essere montanto in modo tangenziale su un carrello per cavi piatti con un semiguscio rotondo angolo tra cavo e semiguiscio a 90 gradi nel quale il rag gio deve essere di gt 70 mm Gli scarichi di tiro sul carrello portacavi devono disporre di morsetti di gomma per evitare un eccessivo schiac
89. e attenuazione della fibra aco in dB km o dB m vedere i dati del costruttore e la potenza di ingresso necessaria sul ricevitore Le perdite di accoppiamento e di disaccoppiamento sul diodo di trasmissione e di ricezione sono gi comprese nei dati per la potenza di trasmissione e la sensibilit di ricezione Fibre ottiche di plastica e di PCF A causa della loro attenuazione della fibra relativamente elevata i cavi in fibra ottica di plastica e di PCF vengono impiegati solo per linee brevi Essi vengono installati in uno spezzone collegamenti FO con accoppiamenti o sdoppiamenti non sono previsti in quanto la distanza realizzabile verrebbe ulteriormente ridotta Le lunghezze massime ammesse dei cavi sono riportate nelle tabelle 3 7 e 3 8 Cavi in fibra ottica di vetro Con i cavi in fibra ottica di vetro possibile realizzare linee chilometriche La posa dei cavi in un tracciato non pu essere realizzata con queste lunghezze La linea FO deve essere quindi composta da diverse linee parziali I punti di collegamento sotto forma di accoppiamenti o sdoppiamenti non possono essere realizzati nella pratica completamente privi di perdite di attenuazione Per le linee di trasmissione con cavi in fibra ottica di vetro inoltre necessario considerare e l attenuazione dei punti di sdoppiamento e l accoppiamento dei punto di giunzione e Durante il calcolo della linea di trasmissione necessario rispettare una riserva di sistema di al
90. e un elemento ausiliario di inserimento e cavi in fibra ottica di vetro multimode 62 5 125 um e i cavi SIMATIC NET Fiber Optic possono essere impiegati per realizzare grandi linee con lunghezze fino a 3000 m Essi sono disponibili gi confezionati e controllati con 4 connet tori BFOC e cavi in fibra ottica singlemode fibra 10 125 um possono essere impiegati per realizzare linee molto estese con lunghezze fino a 15 km Essi sono disponibili su richiesta Con un interfaccia RS 485 possibile combinare tra loro OLM e collegare nella rete ottica PROFIBUS i singoli nodi o interi segmenti elettrici Gli OLM V 3 supportano tutte le velocit di trasmissione PROFIBUS fino a 12 Mbit s Essi sono muniti di un contenitore metallico compatto Sono adatti sia per il mon taggio su una guida ad U sia per il montaggio fisso In caso di struttura verticale gli OLM possono essere allineati senza distanze intermedie Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 8 5 Componenti attivi per reti ottiche Funzioni 8 6 e Riconoscimento automatico di tutte le velocit di trasmissione dati PROFIBUS da 9 6 kbit s a 12 Mbit s compresi 45 45 kbit s PROFIBUS PA e Realizzazione delle seguenti topologie di rete Lineare a stella anello ridondante e Elevata disponibilit grazie alla ridondanza dei mezzi trasmissivi Distanza limi tata tra due OLM nell anello ridondante solo dal raggio di azione ottico e Alla
91. eet teen eee eens Metodo trasmissivo 0 ee een eee nent n eens Metodo trasmissivo in base allo standard EIA RS 485 Metodo trasmissivo per componenti ottici eee eee Metodo trasmissivo per tecnica a raggi infrarossi senza fili Metodo trasmissivo per PROFIBUS PA 2 Topologie delle reti SIMATIC NET PROFIBUS 2 1 Topologia delle reti RS 485 eee 2 1 1 Componenti per velocit di trasmissione fino a 1 5 Mbit s 2 1 2 Componenti per velocit di trasmissione fino a 12 Mbit s N MYhyhyhyhH gt 22 a b i oe k ld ek DAWN ok cn NO 2 2 Topologie di reti ottiche 0 tenes 2 2 1 Topologia con interfacce ottiche integrate 2 2 2 Topologie con OLM eens 2 2 3 Combinazione di interfacce ottiche integrate e OLM 2 3 Topologie di rete senza fili 2 4 Topologie con PROFIBUS PA cece eee eee eens 2 5 Accoppiamento ad altra rete 0 0 0 cece tees 2 5 1 Accoppiatore DP PA c eects 2 5 2 Passaggio a PROFIBUS PA 2 5 3 Accoppiatore DP PA c cece 2 5 4 DP PACLINK a ee aa ea 2 5 5 Passaggio da PROFIBUS DP a RS 2320 2 5 6 Passaggio con DP AS Interface Link 650 2 5 7 Passaggio con DP AS Interface Link 20 2 5 8 Passaggio da PROFIBUS DP a instabus EIB 3 Progettazione di reti
92. funzione con PG e PC Nei connettori di bus con connettore femmina PG tutti i contatti 1 1 sono collegati con i poli del connettore vale a dire che l assegnazione dei pin corrisponde allas segnazione dell apparecchio collegato Assegnazione dei pin del connettore Sub D La tabella 4 5 riporta l assegnazione dei pin del connettore Sub D a 9 poli Tabella 4 5 Assegnazione dei pin del connettore D Sub a 9 poli N pin Nome Denominazione segnale 1 3 5 2 5 i 3 RxD TxD P Cavo dati B 4 2 5 M5V2 Potenziale di riferimento dati dal nodo 6 P5V2 Alimentazione positiva dal nodo 7 z z 8 RxD TxD N Cavo dati A 9 z Reti PROFIBUS SIMATIC NET 4 28 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Figura 4 13 Inserimento dei cavi di bus nel connettore di bus FastConnect 6ES7972 0B 50 0XA0 Figura 4 14 Inserimento dei cavi di bus nel connettore di bus FastConnect 6G1500 0FC00 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 29 Componenti passivi per reti RS 485 4 2 3 4 30 Operazioni per la preparazione del cavo FC con il FastConnect Stripping Tool Le operazioni del sistema FastConnect vengono illustrate sulla base del connettore di bus FastConnect con uscita del cavo a 90 6ES7972 0BB50 0XA0 Queste operazioni valgono anche per il connettore di bus FastConnect con uscita cavo a 180 6GK1500 0FC00 1 Impugnatura
93. have been transposed No partner module connected or partner module is not switched on Connected partner module is defective Send time of connected partner module has been exceeded An optical fiber line is broken Optical fiber link to partner module is too long Loose connection in an optical fiber connector Optical fiber in the optical fiber connector is loose When using a redundant optical ring if a fault in the optical fiber has been corrected but the port LEDs on both of the OLMs concerned still light red check whether parameter HSA has been set as described the in Chap 3 3 Fault occurs periodically see above Loose connection in an optical fiber connector Optical fiber in the optical fiber connector is loose Only one active bus subscriber is connected which only sends tokens to itself A fault should not be signaled as soon as a second subscriber is activated Operating mode Line without optical fiber link monitoring Signals are received at the optical port No transmitting bus subscriber present Send and receive optical fibers have been transposed No partner module connected or partner module is not switched on Connected partner module is defective Table 2 What the LED indicators and signaling contacts mean 26 Signaling contact no signal no signal signal no signal no signal no signal signal signal no signal
94. la definizione generale PCF Local Area Network Light Emitting Diode Cavo a fibre ottiche Optical Bus Terminal Optical Link Module Polymer Cladded Fiber con lo stesso significato di fibra HCS Organizzazione tedesca di supporto per utenti PROFIBUS Polymer Optical Fiber con lo stesso significato di cavo a fibre ottiche di plastica Periferia decentrata PROFIBUS Secure Electrical Low Voltage tensione di sicurezza a basso voltaggio Underwriter Laboratories Associazione elettronica tedesca PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Siemens AG SIMATIC NET A amp D PT2 Postfach 4848 D 90327 Niirnberg Mittente Indicare il corrispondente ramo industriale 00000 Nome Funzione Ditta Via Citta Telefono Industria automobilistica Industria chimica Industria elettronica Industria alimentare Tecnica di controllo e strumentazione Tecnica meccanica Petrolchimica u 020202000 Industria farmaceutica Industria delle materie plastiche Industria cartaria Industria tessile Impresa di trasporti Altre Critiche suggerimenti Vi preghiamo di volerci comunicare critiche e suggerimenti atti a migliorare la qualit e a faci litare l uso della documentazione Vi saremmo quindi grati se vorreste compilare e spedire alla Siemens il seguente questionario Servendosi di una scala di valori da 1 per buono a 5 per scadente Vi preghiamo di dare u
95. m grate OBT Tipo di fibra Fibra a salto d indice Diametro del nucleo 980 um 200 um Materiale del nucleo Polimetilmetacrilato PMMA Vetro di quazo Diametro esterno cladding 1000 um 230 um Materiale cladding Polimero speciale al fluoro Guaina interna e materiale PVC PA e colore grigio nero e arancione senza guaina interna e diametro 2 2 0 01 mm 2 2 0 01 mm Guaina esterna e materiale PVC PVC e colore lilla lilla Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Tabelle 7 1 Propriet dei cavi in fibra ottica seguito Denominazione Numero di fibre SIMATIC NET PROFIBUS Plastic Fiber Optic con coduttori du plex Plastic Fiber Optic cavo standard PCF Fiber Optic cavo standard Attenuazione a Lunghezza d onda lt 230 dB km 660nm lt 10 dB km 660nm Scarico di tiro Rinforzi in kevlar Rinforzi in kevlar Forza di tiro massima am messa e momentanea e continuativa lt 50N Non adatto per forza di tiro continuativa lt 100N Non adatto per forza di tiro continuativa lt 500N lt 100N solo su scarico di tiro lt 50 N su connettore o monoconduttore Resistenza alla pressione tra lt 35N 10cm lt 100N 10cm lt 750 N 10cm sversale per 10 cm di lun ghezza cavi momentanea Raggi di curvatura e un unico ciclo di curvatura gt 30 mm gt 100 mm gt 75mm senz
96. no signal Version 1 1 8 00 5 LED Indicators and Troubleshooting 5 2 Troubleshooting 5 2 Troubleshooting This chapter helps you to localize faults after they have been indicated by LEDs or signal contacts Please also refer to the description of the LED indicators in 5 1 p 25 Fault indicated on the system LED See description of the LED indicators in 5 1 p 25 Fault indicated on CH1 Check the following the DIL switch SO is in Position 1 if the OLM is connected to the electrical star segment of a star topology see Chap 3 2 Star topology p 12 the fault is still displayed after removal of the RS485 connector Still displayed No longer displayed Device is defective Replace the OLM The fault lies in the RS485 bus segment Check all RS485 connectors as described in 4 4 3 Connecting the electrical RS 485 bus lines p 22 the structure and shielding of the RS485 bus segment the RS485 bus segment using a PROFIBUS bus monitor the configuration of all bus subscribers This is not the case if the monomaster of a PROFIBUS network is connected to the RS485 bus segment which is to be examined Replace the OLM concerned with another OLM from the network and then carry out the test described above If the OLM still malfunctions when connected elsewhere the device is defective Replace the OLM If the OLM does not malfunction elsewhere the fault lies in the RS485 bus segment Car
97. of the cable you are using Excessive transverse compressive load can for example result by using screw clamps to secure the cable Always use the pulling loop to pull in the PCF standard cable Never pull in the cable by the connectors or stripped cords Only use PCF fiber optic cables with devices approved for this FO cable type Keep to the maximum permitted cable lengths When cutting cables to length make sure that no loops are formed and that the cable is not twisted Loops and torsion under tensile load can cause kinks or cracks that may mean irreparable damage to the cable Follow the steps outlined in these instructions Make sure that the outer jacket and buffers of the cable are not damaged Never insert contaminated connectors in the device sockets The optical transmitter and receiver elements could otherwise be destroyed When fitting the cable to connectors make sure that the transmitted and received data are crossed in the cable Page 3 SIMATIC NET PROFIBUS PCF Fiber Optic Standard Cable Using the Pulling Loop lt 4 Protective sleeve Die SIMATIC NET PCF Fiber Optic Standard cable is fitted T C tensile load is applied to the loop and is distributed over with a pulling loop at one end It consists of the loop and a e Kevlar fibers strain relief elements of the stangar cable The protective sleeve surrounds the cores with their prot ctive sleeve preassembled connectors and prevents them from kinking Cau
98. of these contents The details and information in this manual are regularly controlled and any corrections and amendments which may prove to be necessary are included in subsequent editions We welcome any suggestions for improvement Siemens AG 1996 to 1999 Subject to technical alterations Siemens Aktiengesellschaft Printed in the Federal Republic of Germany Kapitel Contents 1 Introduction pci ai pila iii ia a i iaia ia 2 General Functions 5 0u u0sun0 0540002120000 Pie ie 2 1 Non operating mode related functions 2 2 Operating mode related functions 3 Network Topologies ene aaraa arenaer Sl Eine t0pology ir se ees 2 ER ae cada iene E A R E S E EA EES ENER ee 3 1 1 Line topology with optical fiber link monitoring and segmentation 3 1 2 Line topology without optical fiber link monitoring LL Si2 Siar topology iii chee de wih a ed Pa Pattee dees eee 3 3 Redundant opticalring zu 444 4 2 sete eeetad OE ee Lee bee E a Pe eee 4 Setting Up 22 22 2 0 eee a BER ee eA ey ha ai 4 1 Safety NOTCE oiran RA pe eee ede RR 4 2 General information about setting Up LL 4 3 Setting compatibility operating mode and transmitting power een een 4 3 1 Setting the compatibility LL 4 3 2 Setting the operating mode eee 4 3 3 Reducing the optical transmitting power on the OLM P11 and OLM P12 AA Installation 22 42 2a san ea rale aa e a 4 4 1 Connecting t
99. p es misure di protezione contro sovratensioni tracciati dei cavi e Il numero di repeater RS 485 tra due terminali di dati qualsiasi limitato ad un massimo di 9 e In caso di strutture estese con repeater risultano tempi di trasmissione maggiori che vanno eventuamente tenuti in considerazione durante la progettazione della rete vedere capitolo 3 3 Terminazione dei cavi 3 2 Indipendentemente dalla velocit di trasmissione le estremit di tutti i segmenti devono essere chiuse Per eseguire questa operazione nei relativi elementi di al lacciamento necessario attivare la terminazione del cavo che risulta da una com binazione di resistenze Dopo l attivazione di una combinazione di resistenze non solo pi ammessi ulteriori spezzoni di cavo Per permettere che la terminazione del cavo diventi attiva deve essere collegata alla tensione A tale scopo il relativo terminale di dati o repeater RS485 deve es sere alimentato In alternativa come terminazione del cavo permanente pu es sere impiegato un terminator PROFIBUS Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Avvertenza Non ammessa l interruzione della tensione di alimentazione delle terminazioni dei cavi disinserendo il terminale di dati o il repeater oppure sfilando il connettore di bus o il cavo di derivazione Se l alimentazione continua delle terminazioni dei cavi non garantita il Terminator PROFIBUS
100. per la preparazione rapida del cavo per interno vedere capitolo 4 2 3 Rispetto al cavo di bus standard il cavo di posa interrata presenta le seguenti pro priet e una maggiore resistenza allo sfregamento e una maggiore resistenza a olio e lubrificanti secondo VDE 0472 parte 803 tipo di prova B e resistenza a radiazioni UV e un maggiore diametro esterno e peso e il materiale della guaina infiammabile e resistente ad acqua e vapore Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 13 Componenti passivi per reti RS 485 Impiego Grazie alla guaina esterna supplementare di PE questo cavo adatto per l instal lazione diretta nel terreno cablaggio Campus 4 1 7 FC Trailing Cable cavo da trascinamento Materiale di riempimento Guaina esterna di PUR Schermo a maglia i in rame Conduttore interno wages a trefoli in rame Foglio di schermatura in alluminio Protezione di isolamento in PE cellulato Foglio in materiale sintetico Figura 4 7 Principio di struttura del cavo da trascinamento Cavo da trascinamento 6XV1 830 3EH10 Il cavo da trascinamento 6XV1 830 3EH10 corrisponde alla resistenza massima del conduttore riportata nella specifica di EN 50170 tipo di cavo A con conduttori interni a trefoli in rame ca AWG24 19 36 Questo scostamento causa una lunghezza ridotta del segmento osservare la ta bella nel capitolo 3 Istruzioni di progettazione Rispetto al cavo
101. received within 300 ms or a received message takes longer than 300 ms Note The activate signaling contact if problems occur in reception configuration should not be set on the PROFIBUS ILM in the master subnet if its partner ILM only has one slave node that is not addressed during this time 5 6 2 Monitoring the Optical Link with an Acknowledgment Pulse During configuration the user can activate a mechanism so that an acknowledgment pulse is expected from the receiving station after data have been sent This acknowledgment must be received within the time set as the interval between sending and transmitting on PROFIBUS 11 bit times This acknowledgment pulse is not passed on to the electrical channels of the sending or receiving PROFIBUS ILM but is restricted exclusively to the optical transmission link Note The monitor link with acknowledgment pulse configuration must be activated on both PROFIBUS ILMs of a point to point link 19 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 This monitoring logic must not be used on a point to multipoint link Otherwise problems can occur in the PROFIBUS network The display of the acknowledgment pulse function is one of the functions of the TX LED With the yellow TX LED the PROFIBUS ILM indicates that data are being sent on the optical channel of the PROFIBUS ILM The pulse for the LED is extended to approximately 300 ms so that
102. terminale per segmento di bus 21 Allacciamento per cavo di bus del segmento 2 Slitta per il montaggio e lo smontaggio del repeater RS 485 su guida profilata a norma Interfaccia per PG OP sul segmento di bus 1 Tensione di alimentazione LED 24V LED per indicare il funzionamento del bus per il segmento 1 Struttura del repeater N DO L M PE M52 5 eeeet 7 I DI L Sl e e A1 Bi Ai un A ON oe METTE oe oP orc 2 ae 3 SIEMENS eke gt gt e l gt LED per indicare il funzionamento del bus per il segento 2 1 Con la resistenza terminale inserita viene scollegato il rispettivo allacciamento di bus de stro vedere figura 5 3 Avvertenza Il morsetto M5 2 dell alimentazione vedere tabella 5 1 N serve come massa di riferimento per misurazioni del segnale in caso di guasto e non deve essere ca blato Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 Dati tecnici La tabella 5 2 riporta i dati tecnici del repeater RS 485 Tabella 5 2 Dati tecnici del repeater RS 485 Dati tecnici Tensione di alimentazione e Tensione nominale e Ondulazione limite statico DC 24 V da DC 20 4 V a DC 28 8 V Corrente assorbita alla tensione nominale e senza utilizzatore collegato al co
103. to the double tokens or frame collisions Note If a module with two optical ports is used at the beginning or end of a line the optical port which is not assigned must be switched to the operating mode Line without fiber link monitoring so that it does not signal a break in the fiber line Please note that optical ports which are not connected must always be fitted with protective caps to guard against extraneous light and dirt 10 Version 1 1 8 00 3 Network Topologies 3 1 Line topology 3 1 2 Line topology without optical fiber link monitoring Use this operating mode if you connect a PROFIBUS OLM with another optical fiber network component which does not send a frame echo and does not expect or is not compatible with a frame echo in accordance with PROFIBUS guidelines optical electrical converter Monitoring mechanisms Send echo Monitor echo Suppress echo Monitor Segmentation Individual fiber links are not monitored in this operating mode Version 1 1 8 00 no no no no no 11 3 Network Topologies 3 2 Star topology 3 2 Star topology Electrical star segment u Ll I I A Vv Vv Vv Vv z E E lele Z 50 1 Z S0 1 Z 80 1 RS 485 bus line OLM P11 OLM G12 OLM G11 1300 Optical fiber
104. to the maximum permitted cable lengths When cutting cables to length make sure that no loops are formed and that the cable is not twisted Loops and torsion under tensile load can cause kinks or cracks that may mean irreparable damage to the cable Follow the instructions in this manual and use the tools described here Set the cutting depth of the cable knife part of the stripping tool set order no 6GK1 905 6PA10 to a depth of 1 5 mm prior to use The cutting depth is set with the adjusting screw at the end of the handle Turning the adjusting screw clockwise increases the cutting depth Turning the adjusting screw counter clockwise reduces the cutting depth Make sure that the outer jacket and buffers of the cable and the plastic fibers are not damaged When stripping the buffer from the fiber use only the opening in the stripper marked AWG 16 Nicks or scratches can allow light to escape and can therefore lead to increased attenuation values and failure of the transmission path With time such defects can also lead to breaks in the fiber and to failure of the network When grinding and polishing make sure that there is only slight pressure from the connector on to the foil to avoid fusion of the connector and fiber plastic Make sure that you keep to the bending radii when grinding and polishing particularly when the cables are supported to provide mechanical strain relief In this case make sure that you strip an adequate len
105. trasmissione duplex tra due nodi sono di conseguenza necessarie due fibre una per ogni direzione di trasmissione componenti ottici per PROFIBUS permettono di realizzare strutture lineari a stella e ad anello Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche 7 2 Cavi in fibra ottica di plastica Cavo in fibra ottica di plastica cavi in fibra ottica di plastica vengono impiegati per il collegamento di Optical Link Module con allacciamenti per cavi FO in fibra di plastica OLM P bus terminal ottici OBT e apparecchi con interfaccia ottica integrata Essi costituiscono un al ternativa economica rispetto ai cavi in fibra di vetro Propriet dei cavi in fibra ottica Impiegare cavi in fibra ottica di plastica e PCF della Siemens con le seguenti pro priet Tabelle 7 1 Propriet dei cavi in fibra ottica Denominazione SIMATIC NET PROFIBUS Plastic Fiber Optic Plastic Fiber Optic PCF Fiber Optic cavo con coduttori du cavo standard standard plex Sigla identificativa a norma I VY2P 980 1000 I VY4Y2P 980 1000 I VY2K 200 230 150A 160A 10A17 8B20 Settore d impiego Impiego all interno di Impiego all interno di Impiego all interno di edifici con carico edifici edifici meccanico ridotto come p es laboratori oppure all interno di armadi Lunghezza cavo tra e OLM OLM 50m 80m 400 m e interfacce ottiche inte 50m 50m 300
106. tro varsi in posizione ON fun zione di scollegamento 2 2 Ruotare indietro lo scarico di tiro 5 Chiudere il coperchio di contatto premendolo verso il basso Interrut tore OFF In caso di impiego del connet tore all interno di un seg mento l interruttore deve tro varsi in posizione OFF 3 Aprire verso l alto il coper chio di contatto 6 Se il connettore viene im piegato all interno di un seg mento inserire il cavo in par tenza nel coperchio di con tatto con la contrassegnatura A2 B2 7 Chiudere il coperchio di contatto premendolo verso il basso Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 8 Ruotare indietro lo scarico di tiro 9 Serrare la vite dello sarico di tiro 4 31 Componenti passivi per reti RS 485 4 3 Connettore di bus Impiego Con l aiuto del connettore di bus per SIMATIC NET PROFIBUS possibile e collegare i nodi con un interfaccia Sub D elettrica a 9 poli secondo EN 50170 direttamente ai cavi SIMATIC NET PROFIBUS e allacciare segmenti elettrici o nodi singoli a Optical Link Module OLM OBT allacciare nodi o PG al repeater Avvertenza terminali di bus e i dati meccanici del connettore di bus SIMATIC NET sono con formi ai cavi SIMATIC NET PROFIBUS tipo di cavo A della norma PROFIBUS EN 50170 1 2 Il collegamento del connettore di bus ai cavi con propriet elettri che o meccaniche diverse pu
107. 0 90 mA short circuit proof Signaling contact Maximum switch voltage Maximum switch current 60 V DC 42 V AC safety extra low voltage 1 0A Signal transmission Transmission rate 9 6 19 2 45 45 93 75 187 5 500 kBit s 1 5 3 6 12 Mbit s Setting transmission rate automatic Bit error rate lt 10 Signal processing time any input output lt 6 5 tpit Retimer Input Port 1 to 3 Signal distortion 30 Bit length 0 12 Output Port 1 to 3 Mean bit length 0 01 Safety VDE regulation VDE 0806 EN 60950 and IEC 950 UL CSA approval UL 1950 CSA 950 FM approval in preparation Class 2 Electrical port Input output signal RS 485 level Input dielectric strength 10Vto 15V PIN assignment port 1 in accordance with EN 50170 Part 1 Indirect coupled yes within SELV limits Optical ports Wavelength 660 nm 860 nm 1310 nm Launchable optical power in glass fiber E 10 125 in glass fiber G 50 125 in glass fiber G 62 5 125 in PCF fiber S 200 230 transmitting power Reduced transmitting power Default in plastic fiber S 980 1000 transmitting power Reduced transmitting power Default 19 dBm 15 dBm 17 dBm 13 dBm 17 dBm 9 5 dBm 5 dBm Receiver sensitivity 25 dBm 28 dBm 29 dBm Receiver overload 3 dBm 3 dBm 3 dBm Version 1 1 8 00 31 7 Technical Data
108. 0 0AA4 Edizione 2 05 2000 Protezione contro fulmini e sovratensioni per cavi di bus che si estendono in pi edifici B 2 Protezione antifulmine di cavi di bus Cavi di bus installati all interno di edifici In caso di osservanza delle prescrizioni di installazione per i cavi di bus che si tro vano esclusivamente all interno di un edificio non sono necessarie particolari prote zioni da sovratensioni Cavi di bus che si estendono in pi edifici Poich i cavi di bus tra edifici sono particolarmente soggetti a elevati rischi di so vratensioni scariche di fulmini necessario proteggere da sovratensioni i nodi contenuti nel segmento di bus allacciato dispositivi di protezione antifulmine per cavi di bus vengono realizzati con due diversi componenti la protezione di massima e la protezione di fine Protezione di massima Mentre la protezione di massima installata all ingresso dell edificio impedisce la scarica di fulmini con elevata tensione la protezione di fine installata nelle vici nanze dei terminali rappresenta la limitazione specifica delle sovratensioni per i nodi del bus da proteggere e dispositivi di protezione antifulmine descritti qui di seguito rappresentano un concetto di protezione sviluppato in collaborazione con la ditta Dehn amp S hne per SIMATIC NET PROFIBUS e che possono essere utilizzati per tutte le velo cit di trasmissione da 9 6 kcit s a 12 Mbit s Le ordinazioni vanno inoltrate dire
109. 0 5CA20 0AA4 Edizione 2 05 2000 1 3 RETI PROFIBUS Industrial Ethernet Fast Ethernet Una rete di comunicazione per il livello LAN e il livello di cella con tecnica trasmis siva a banda base secondo IEEE 802 3 e tecnica di accesso CSMA CD Carrier Sense Multiple Access Collision Detection sulla base di e cavo triassiale 50 Q e cavi Twisted Pair 100 Q e cavo in fibra ottica di vetro AS Interface Una rete di comunicazione per l automazione nel livello pi basso di una struttura di automazione per l allacciamento di attuatori e sensori binari all apparecchiatura di automazione via cavo di bus AS I PROFIBUS Una rete di comunicazione per il livello di cella e di campo secondo EN 50170 1 2 con tecnica di accesso ibrida token bus e master slave Il collegamento in rete viene eseguito con cavi a due conduttori cavi in fibra ottica oppure senza fili PROFIBUS PA PROFIBUS PA il PROFIBUS per l automazione di processo PA Esso collega il protocollo di comunicazione PROFIBUS DP alla tecnica trasmissiva IEC 61158 2 Reti PROFIBUS SIMATIC NET 1 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS 1 2 Basi della rete PROFIBUS EN 50170 prodotti SIMATIC NET PROFIBUS e le reti realizzate con questi prodotti sono conformi alla norma PROFIBUS EN 50170 1996 In SIMATIC S7 i componenti SIMATIC NET PROFIBUS possono essere utilizzati anche per la realizzazione di una sotto rete SIMATIC MPI MPI Multipoint Interfa
110. 00 Componenti passivi per reti ottiche Dati per l ordinazione Plastic Fiber Optic confezionato cavo standard per OLM P SIMATIC NET PROFIBUS Plastic Fiber Optic cavo standard I VY4Y2P 980 1000 160A Cavo rotondo resistente con 2 conduttori FO in plastica guaina esterna in PVC e guaina interna in PA per l impiego all interno di edifici confezionato con 2x2 connettori BFOC Lunghezza dei conduttori che sporgono dalla guaina rispettivamente 20 cm per il collegamento di OLM P Lunghezze disponibili 6XV1821 0BH10 6XV1821 0BH20 6XV1821 0BH50 6XV1821 0BN10 6XV1821 0BN15 6XV1821 0BN20 6XV1821 0BN25 6XV1821 0BN30 6XV1821 0BN50 6XV1821 0BN65 6XV1821 0BN80 altre lunghezze su richiesta Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche 7 2 3 Cavo in fibra ottica di PCF Guaina esterna in PVC Scarico di tiro in kevlar ibra di PCF Figura 7 3 Principio di struttura del cavo standard in fibra ottica di PCF Cavo in fibra ottica di PCF cavo standard 6XV1821 1B Il cavo in fibra ottica di PCF cavo standard 6XV1821 1B composto da due fibre di PCF rivestite da elementi di tiro in kevlar e con una guaina esterna viola di PVC La sigla identificiativa a norma I VY2K 200 230 10A17 8B20 Sulla guaina esterna stampata la scritta SIEMENS SIMATIC NET PROFIBUS PCF FIBER OPTIC 6XV1821 1AH10 UL e una marcatura in metri Questo cavo d
111. 00 EMC Directive The SIMATIC NET products named above fulfill the requirements of the following EC directives Directive 89 336 EEC Electromagnetic Compatibility Application The product is designed for use in the following areas Area of Requirement for application Interference emissions Interference immunity Domestic business and EN 50081 1 1992 commercial use as well as in small factories Industrial plants EN 50082 1 1997 EN 50081 2 1993 EN 50082 2 1995 Observe assembly The product complies with the specifications if the assembly guidelines and safety guidelines instructions are observed during installation and operation as described in this Description and Operating Instructions SIMATIC NET Optical Link Modules and the following documentation SIMATIC NET PROFIBUS Networks Manual Declaration of In accordance with the above named EC directive the EC Declaration of Conformity Conformity can be viewed by the authorities responsible at Siemens AG Bereich Automatisierungs und Antriebstechnik Gesch ftszweig Industrielle Kommunikation SIMATIC NET Postfach 4848 D 90327 N rnberg Machine Directive Furthermore the product is a component in accordance with Article 4 2 of the EC Machine Directive 89 392 EWG In accordance with the Machine Directive we are obliged to draw attention to the fact that the designated product is solely designed for installation in a machine Before the end pr
112. 1 Infrared Link Modul ILM The finished construction of the support with two mounting angles and the securing of the PROFIBUS ILM is described in Figures 13 to 15 Mounting bracket 1 Washer Nut M6 na Bolt sia J M 6x16 Toothed ta Secured to a base with two bolts Mounting bracket 2 Site of in stallation Installation of the ILM with a mounting bracket front view Figure 13 Front View of the PROFIBUS ILM Installed with Mounting Brackets 33 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 Washer Nut M6 Bolt M6 x 16 L Two toothed washers Washer i mil Mounting bracket 1 mA Direction of emission Installation of the ILM with mounting bracket top view Figure 14 Top View of the PROFIBUS ILM Installed With Mounting Brackets Copyright by Siemens 34 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Alignment Screw M6 x 16 O by turning Mounting bracket Mounting bracket 2 Threaded cable inlets Cables for PROFIBUS Installation site power supply and signaling contact Installing the ILM with mounting bracket side view Figure 15 Side View of a PROFIBUS ILM Installed With Mounting Brackets By installing angle 1 in different holes on the mounting surface it is possible to turn the PROFIBUS ILM through the vertical axis however the adjustment is not continuous By loosening the M6 securing bolts the PROFIBUS
113. 2 Mbit s oppure il bus terminal BT12M e La lunghezza massima di un segmento non deve superare 100 m e numero di accoppiamenti di bus nodi OLM repeater RS 485 su un segmento limitato ad un massimo di 32 e Per l allacciamento di PG o PC tramite cavo di derivazione pu essere utilizzato solo il cavo di connessione SIMATIC S5 S7 12 MBaud N di ordinazione 6ES7901 4BD00 0XA0 Avvertenza Se vengono utilizzati diversi connettori di bus a brevi distanze elettriche vale a dire che la lunghezza del cavo tra i connettori adiacendi inferiore a 1 m p es diversi slave in un armadio necessario evitare che diversi connettori di bus siano sfilati contemporaneamente per un periodo prolungato Una situazione di questo tipo non comporta normalmente guasti tuttavia pu ridurre la sicurezza di funzionamento immunit ai disturbi di un segmento Reti PROFIBUS SIMATIC NET 3 8 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti 3 1 4 Progettazione di reti elettriche con repeater RS 485 Repeater RS 485 Per aumentare il numero di nodi gt 32 in una rete o la lunghezza del cavo tra due nodi i segmenti possono essere collegati ad una rete con repeater RS 485 La figura 3 1 illustra una combinazione possibile di pi segmenti con una rete tramite repeater RS 485 supportano tutte le velocit di trasmissione comprese tra 9 6 kbit s e 12 Mbit s S7 300
114. 25 C a 70 C da 25 C a 70 C Resistenza all incendio Resistente alla fiamma secondo IEC 60332 3 cat CF Resistente alla fiamma secondo IEC 60332 3 e secondo DIN VDE 0472 parte 804 classe di prova B Indipendenza da alogeno no si Omologazioni UL no no Autorizzazione dell industria no no navale Tabella 7 5 Dati tecnici del cavo da trascinamento flessibile Fiber Optic e del cavo marino in fibre ottiche duplex SIENOPYR Tipo di cavo Fiber Optic flessibile SIENOPYR Settore d impiego Cavo da trascinamento Cavo flessibile per la posa in catene portacavi all interno di edifici e all aperto Cavo marino duplex in fibra ottica Installazione fissa su navi o unit offshore in tutti i locali e sul ponte all aperto Fornitura Confezionato con 4 connettori a metraggio BFOC con lunghezze definite e a metraggio Tipo di cavo AT W11Y ZN MI VHH 2G 62 5 125 Sigla identificativa a norma 11Y2G62 5 125 3 1B200 0 8F600 LG 3 1B200 0 8F600 2x1CU 300V Tipo di fibra Fibra a gradiente d indice Fibra a gradiente d indice multimode 62 5 125 um multimode 62 5 125 um Attenuazione a 850 nm lt 3 1 dB km lt 3 1 dB km Attenuazione a 1300 nm lt 0 8 dB km lt 0 8 dB km Larghezza banda modale a 850 nm 200 MHz km 200 MHz km a 1300 nm 600 MHz km 600 MHz km Numero di fibre 2 2 Struttura del cavo Cavo sezionabile per esterno Cavo sezionabile
115. 3 Disegno in scala del PROFIBUS terminator F 4 Disegno in scala del bus terminal RS 485 2 00 ee ee eee F 5 Disegni in scala del bus terminal BT12M 000 cee eens F 6 Disegni in scala dell optical bus terminal OBT F 7 Disegni in scala degli Infrared Link Module ILM Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 F 8 Disegni in scala dell Optical Link Module OLM G Istruzioni per l uso ILM OLM OBT H Informazioni generali H 1 Indice delle abbreviazioni Bibliografia J SIMATIC NET Supporto e training Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS RETI PROFIBUS 1 1 Reti locali LAN nell automazione di produzione e di processo 1 1 1 Introduzione generale Sistemi di comunicazione La potenzialit dei sistemi di comando non viene pi determinata solo dai control lori programmabili ma anche dalla loro locazione Oltre alla visualizzazione dell im pianto al comando e alla supervisione necessario un sistema di comunicazione di elevate prestazioni Sistemi decentrati Nell automazione di produzione e di processo vengono sempre pi impiegati si stemi di automazione decentrati Ci significa che un compito di comando com plesso viene suddiviso in applicazioni parziali minori utilizzando sistemi di comando decentr
116. 3 FC Food Cable cavo di bus con guaina esterna in PE 4 1 4 FC Robust Cable cavo di bus con guaina esterna in PUR 4 1 5 PROFIBUS Flexible Cable cavo di bus resistente alla torsione 4 1 6 FC Underground Cable cavo di posa interrata 4 1 7 FC Trailing Cable cavo da trascinamento 4 1 8 PROFIBUS Festoon Cable cavo di bus per strutture sospese a festoni 4 1 9 Cavo marino SIENOPYR FR 4 2 Connettore di bus FastConnect 0 ccc eee eee 4 2 1 Sistema FastConnect cece cee cece nennen nenn 4 2 2 Settore di impiego e dati tecnici del connettore di bus FastConnect 4 2 3 Operazioni per la preparazione del cavo FC con il FastConnect SHIPPING TOO 2 che ap 4 3 Connettore di DUS Li 4 3 1 Settore di impiego e dati tecnici del connettore dibus 4 4 Collegamento del cavo di bus al connettore dibus 4 4 1 Collegamento del cavo di bus al connettore di bus 6ES7 972 0B 11 4 37 4 4 2 Collegamento del cavo di bus al connettore di bus 6ES7 972 OBA30 OXAD0 Li 4 40 4 4 3 Collegamento del cavo di bus al connettore di bus 6ES7 972 0B 40 4 42 4 5 Montaggio del connettore di bus con uscita assiale del cavo 4 6 Innesto del bus sull unit 4 7 Bus terminal per reti RS 485 4 7 4 Versioni alternative c ect teens 4 7 2 Struttura e tipo di funzionamento del bus terminal RS 485
117. 3 cat A Indipendenza da alogeno no si Omologazioni UL no no Autorizzazione dell industria no si navale 1 con conduttori in rame non sollecitati 2 con conduttori di rame sollecitati al massimo 6 A 7 16 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche 7 3 1 Cavo standard Fiber Optic Guaina esterna in PVC nero Guaina interna in PVC grigio Elemento di supporto filati di vetro Filati di kevlar Fibra di vetro G62 5 125 um Figura 7 4 Struttura del cavo standard Fiber Optic Cavo standard Fiber Optic 6XV1820 5 Il cavo standard Fiber Optic contiene 2 fibre a gradiente d indice multimode del tipo 62 5 125 um La guaina esterna riporta la scritta SIEMENS SIMATIC NET FIBER OPTIC 6XV1 820 5AH10 ogni ca 50 cm La marcatura in metri consiste in un trattino verticale e un numero a 4 cifre che facilita il calcolo della lunghezza di un cavo in stallato Propriet Il cavo standard Fiber Optic presenta le seguenti propriet Impiego calpesabile resistente alla fiamma secondo IEC 60332 3 cat CF non esente da alogeni disponibile a metraggio fino a 4000 m confezionato con 4 connettori BFOC e disponibile con lunghezze fino a 1000 m Il cavo standard Fiber Optic un cavo universale per l impiego all interno di edifici e all aperto Esso adatto per il collegamento di interfacce ottiche che lavorano con campo di lu
118. 3 m 6ES7 901 4BD00 0XA0 Repeater RS 485 per PROFIBUS DC 24 V contenitore IP 20 6ES7 972 0AA01 0XA0 Bus terminal BT12M 6GK1 500 0AA10 Optical Link Module OLM V3 6GK1 502 C_00 Optical bus terminal OBT 6GK1 500 3AA0 PROFIBUS terminator 6ES7 972 0DA00 0AA0 Reti PROFIBUS SIMATIC NET 2 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS 2 2 Topologie di reti ottiche Conversione elettrica ottica Se si intendono realizzare lunghe distanze con il bus di campo indipendentemente dalla velocit di trasmissione o dal traffico di dati sul bus soggetto a campi di di sturbi elettromagnetici utilizare cavi in fibra ottica anzich cavi di rame Per la conversione da cavi elettrici a cavi in fibra ottica esistono le seguenti possi bilit e Alla rete ottica i nodi PROFIBUS con interfaccia PROFIBUS DP RS 485 ven gono allacciati tramite bus terminal ottici OBT oppure tramite Optical Link Mo dule OLM e nodi PROFIBUS con interfaccia FO integrata p es ET 200M IM 153 2 FO S7 400 IM 467 FO possono essere collegati direttamente in una rete ottica con topologia lineare e Reti ottiche con grande estensione o come strutture ad anello ridondante de vono essere realizzate con OLM La realizzazione di reti ottiche con Optical Link Module OLM descritta dettaglia tamente nei capitoli successivi del presente manuale Altre informazioni pe
119. 3 x 55 Provvedere ad un collegamento elettrico affidabile con un cavo di terra di min 2 5 mm tra l allacciamento PE della scatola del modulo e la piastra di montag gio messa a terra SIEMENS SIMATIC NET PROFIBUS Optical Bus Terminal 0000 00000 6GK1500 3AA00 1121314151617 NEC CLASS2 24VDC 200 mA Figura 5 2 Installazione di un modulo su una piastra di montaggio PROFIBUS Optical 5 4 Busterminal OBT C79000 G8972 C122 02 Messa in funzione Istruzioni di montaggio per Fiber Plastic Optic con serie di foto Un istruzione di montaggio esplicativa con serie di foto per la confezione di cavi a fibre ottiche di plastica riportata in Internet e tedesco http www ad siemens de csi net e inglese http Awww ad siemens de csi_e net Selezionare in questa pagina di Internet SEARCH funzione di ricerca immettere il numero 574208 sotto ID e avviare l operazione di ricerca Allacciamento della tensione d esercizio NEC CLASS2 24VDC 200 MA QOD Figura 5 3 Assergnazione dell allacciamento del blocco di morsetti a 3 poli morsetto di terra PE e tensione d esercizio M L e Alimentare PROFIBUS OBT solo con una tensione di sicurezza a basso voltag gio stabilizzata secondo IEC 950 EN 60 950 VDE 0805 con max 18V e max 32V tipo 24V La fonte di tensione deve corrispondere alle prescrizioni di NEC classe 2 in base all autorizzazione UL CSA Se PROF
120. 30 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Confezione sul luogo di installazione Se la confezione dovesse essere eseguita sul luogo di installazione la SIEMENS mette a disposizione questo servizio vedere appendice 1 2 sono disponibili connettori BFOC e attrezzi speciali adatti vedere 1 2 Avvertenza connettori per FO di vetro devono essere confezionati eslcusivamente da perso nale specializzato Se montati in modo specializzato i connettori permettono un attenuazione di inserzione molto ridotta e un mantenimento dei valori anche dopo diversi cicli di innesto Cavi confezionati Per poter impiegare cavi in fibra ottica di vetro anche in assenza di personale spe cializzato essi sono disponibili anche preconfezionati con 4 connettori BFOC dati per l ordinazione sono riportati nel catalogo SIMATIC NET attuale IK10 Avvertenza connettori per cavi FO sono sensibili a sporco e sollecitazione meccanica della superficie frontale Proteggere allacciamenti aperti con i cappucci parapolvere for niti Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 31 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti ottiche Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 8 1 Componenti attivi per reti ottiche 8 1 Figura 8 1 Bus terminal ottico OBT SIEMENS cn C SIMATIC NET de PROF
121. 300 15 km Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Budget di attenuazione per OLM G11 G12 per un collegamento punto a punto con la lunghezza d onda 860 nm Attenuazione per cavo Tipo di fibra Attenuazione Lunghezza del aro cavo L 62 5 125 um 3 5 dB km 2 85 km L aro 10 0 dB Attenuazione per elementi di giunzione Agiunz Quantit 0 4 dB 1 Quantit 0 4 dB Agiunz Attenuazione per collegamenti di sdoppiamenti Asdopp Quantit 0 2 dB 3 Quantit 0 6 dB Asdopp Attenuazione della linea di trasmissione Alinea 11 0 dB Dati caratteristici degli OLM G11 G12 potenza accoppiabile nella fibra 62 5 125 um Pa min 13 dBm Sensibilita del ricevitore Pe min 28 dBm Valore massimo ammesso di attenuazione Amax Pa min Pe min 15 0 dB Riserve di sistema Amax Alinea 4 0 dB La linea di trasmissione pu essere realizzata nella forma prevista Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Budget di attenuazione per OLM G11 1300 G12 1300 per un collegamento punto a punto con lunghezza d onda X 1310 nm Attenuazione per cavo Tipo di fibra Attenuazione Lunghezza del aro cavo L 62 5 125 um 1 0 dB km 9 km L aro 9 0 dB Attenuazione per elementi di giunzione Agiunz Quantit 1dB 0 Quantit 0 dB Agiunz Attenuazione per collegamenti di sdoppiamenti Asdopp Quantit
122. 4 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors Stripping the Outer Jacket of the SIMATIC NET PLASTIC FIBER OPTIC Standard Cable Press the clamp of the cable knife in the Rotate the cable knife twice Slit the outer jacket up to the end of the direction of the arrow Insert a length of cable 20 cmof cable Note The cable knife must be set to a cutting depth of 1 5 mm A Remove the outer jacket Kevlar fibers and foil working from the end of the cable towards the round cut leaving the black and orange FO cords Make a second slit up to the end of the cable on the opposite side of the jacket First turn the cable through 180 Then make a second slit up to the end of the cable starting from the round cut Cut off remnants of the jacket Kevlar Standard cable with the outer jacket fibers and foil with scissors stripped Page 5 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors Separating the SIMATIC NET PLASTIC FIBER OPTIC Duplex Cord Insert a sharp knife 20 cm from the end Caution Separated duplex cords of the cable in the groove between the Do not split the cords simply by hand two cords and split the cords up to the since the fibers can easily be bent end of the cable beyond the minimum bending radius Caution The buffer of the cords must not be damaged Page 6 SIMATIC NET PROFIBUS Plastic Fiber Opt
123. 4 1 8 PROFIBUS Festoon Cable cavo di bus per strutture sospese a festoni Guaina esterna di PVC speciale Conduttore interno a trefoli in rame Foglio in materiale sintetico Schermo a maglia in rame Protezione di isolamento in PE cellulato Foglio di schermatura in alluminio Foglio in materiale sintetico Figura 4 9 Principio di struttura del cavo di bus per strutture sospese a festoni Cavo di bus per strutture sospese a festoni 6XV1 830 3GH10 Il cavo di bus per strutture sospese a festoni 6XV1 830 3GH10 corrisponde alla resistenza massima del conduttore riportata nelle specifiche di EN 50170 tipo di cavo A con conduttori interni a trefoli in rame ca AWG24 19 36 Questo scostamento causa una lunghezza ridotta del segmento osservare la ta bella nel capitolo 3 Istruzioni di progettazione Grazie alla struttura flessibile il cavo di bus per strutture sospese a festoni 6XV1830 3GH10 permette l impiego in festoni con anelli di cavi di piccole e grandi dimensioni Il cavo ha un peso proprio ma non adatto per forze di tiro gt 80 N Sulla guaina esterna stampigliata la scritta SIMATIC NET PROFIBUS RS 485 Festoon Cable 6XV1830 3GH10 UL CMX 75 C SHIELDED AWG 24 e una marcatura in metri Per facilitare un installazione senza torsioni sulla guaina esterna stampata una linea in direzione longitudinale conduttori a trefoli possono essere avvitati solo con morsetti a vite e con l
124. 485 1983 Standard for Electrical Characteristics of Generators and Receivers for Use in Balanced Digital Multipoint Systems IEC 61158 2 to 6 1993 2000 Digital data communications for measurement and control Fieldbus for use in industrial control systems DIN VDE 0100 Parte 410 Installazione di impianti ad alta tensione con tensioni nominali fino a 1000 V misure di sicurezza protezioni contro correnti pericolose e DIN VDE 0100 parte 540 Installazione di impianti ad alta tensione con tensioni nominali fino a 1000 V scelta e installazione di mezzi d esercizio messa a terra conduttore di protezione conduttore equipotenziale Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Bibliografia ITI 8 9 10 11 12 13 DIN EN 60950 Sicurezza di installazione della tecnica di informazione comprese le macchine elettriche per l ufficio IEC950 1991 modificata e IEC 950A1 1992 Versione tedesca EN 60950 1992 A1 1993 DIN norma industriale tedesca societ registrata Berlino VG 95375 Parte 3 Compatibilit elettromagneticha nozioni di base e provvedimenti per lo sviluppo di sistemi Parte 2 cablaggio dicembre 1994 DIN norma industriale tedesca societ registrata Berlino SIMATIC S5 Sistemi periferici decentrali ET 200 SIEMENS AG N di ordinazione EWA 4NEB 780 6000 01c Edizione 4 SIMATIC Controllore programmabile S7 400 Installazione e impiego Fascicolo SI
125. 50170 1 2 Il collegamento del connettore di bus ai cavi con propriet elettri che o meccaniche diverse pu comportare disturbi di funzionamento Sistema FastConnect Settore d impiego Struttura 4 24 PROFIBUS FastConnect un sistema per la confezione rapida e semplice di cavi di rame PROFIBUS Il sistema costituito da componenti compatibili tra loro e cavi di bus FastConnect per il montaggio rapido e FastConnect Stripping Tool attrezzo per togliere l isolamento e connettore di bus FastConnect per PROFIBUS con tecnica a perforazione d isolante Avvertenza Tutti i cavi di bus PROFIBUS FastConnect possono essere allacciati a tutti i con nettori di bus convenzionali e muniti di morsetti a vite Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Funzioni La tecnica FastConnect consente un collegamento rapido di connettori PROFIBUS ai cavi di bus PROFIBUS La struttura speciale dei cavi di bus FastConnect consente l impiego del FastCon nect Stripping Tool con il quale possibile togliere la guaina esterna e lo schermo a maglia in un unica operazione Per i connettori di bus FastConnect il collega mento di cavi preparati in questo modo viene eseguito con la tecnica a perfora zione d isolante Designed for Industry e Riduzione dei tempi di collegamento di terminali di dati togliendo la guaina esterna e lo schermo a maglia in un unica oper
126. 530 3AC30 0BA1 Infrared Link Modul ILM 3 Introduction The SIMATIC NET PROFIBUS ILM Infrared Link Module is intended for use in PROFIBUS networks It allows the conversion of electrical PROFIBUS interfaces RS 485 level into transmittable light signals in the infrared invisible wavelength range and vice versa With the PROFIBUS ILM it is possible to link an existing PROFIBUS network with a second PROFIBUS network without a physical cable connection between the two subnets electrical cables or fiber optic cable The PROFIBUS ILM is therefore particularly suitable for cableless links with the following gt Turntables gt Automatic transport systems gt Modifiable test equipment The transmission is optical and therefore depends on line of sight contact between two PROFIBUS ILMs Apart from point to point links point to multipoint links are also possible At least two PROFIBUS ILMs are necessary for a transmission link 7 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 4 Description of the Device Each PROFIBUS ILM has an optical and an electrical channel each with a transmitter and receiver section The sending PROFIBUS node generates an electrical signal with RS 485 level that is transferred via the PROFIBUS cable to the PROFIBUS ILM of the sending PROFIBUS node The PROFIBUS ILM converts this electrical signal to a coded light signal This coded light signal is detected by the optical receiver
127. 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 6 2 Setting the Transmission Rate To operate the PROFIBUS ILM the transmission rate must be set manually The transmission rates normal in PROFIBUS 9 6 Kbps to 1 5 Mbps are possible and in addition also the transmission rate of 45 45 Kbps The transmission rate of the attached bus nodes must be within the tolerance of 0 3 The user must set the same transmission rate on all PROFIBUS ILMs in a PROFIBUS network Setting 0 As shipped All switches 0 201 Setting 1 Switch for t setting the transmission rate TER on A om sda 7 j ee D ve TEES DA Figure 8 Setting the Transmission Rate 23 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 6 3 Operation With Acknowledgment Pulse For operation of the PROFIBUS ILM with acknowledgment pulses a manual setting must made during configuration Operation with acknowledgment pulse is only intended for the use of point to point links between two PROFIBUS ILMs Note If a point to multipoint topology is being used this mechanism must be deactivated otherwise problems can occur on the bus DEBOBBBB se Setting 1 All switches 0 ij Switch 4 Link monitoring with acknowledgment pulse 201 Operation without acknowledgment pulse Operation with acknowledgment pulse Figure 9 Operation with Acknowledgment Pulse and the Corresponding Switch Setting Copyrig
128. 9 Con riserva di modifiche tecniche Siemens Aktiengesellschaft N di ordinazione 6GK 1970 5AC20 0AA4 Simboli Cavo con connettore PROFIBUS 830 1 T Cavo con connettore PROFIBUS 830 2 T Cavo di bus cavo a due conduttori Cavo FO duplex Trasmissione senza fili a raggi infrarossi Connettore di bus 0000 E Ooog0000 00000000 DI oes f afafataTala 20500000 QVODDODO S7 300 Am E S7 400 i el 0 ET200S um OP25 zu ET 200M con IM 153 2 FO PG PC OP Diramazione ASI Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Index 1 Simboli Optical Link Modul OLM Terminale di bu ottico OBT oo p om a Infrared Link Module ILM Repeater Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Index 2 1 RETI PROFIBUS un een Reti locali LAN nell automazione di produzione e di processo Introduzione generale e tne Informazioni generali relative al sistema SIMATIC NET Basi della rete PROFIBUS cee eee Norme e standard ete eet n eee nees Metodo di accesso 1
129. 9 poli 9 6 kbit s 12 Mbit s DC5Vt5 Tensione di sicurezza a basso voltaggio SELV secondo EN 60950 90 mAasV 0 45 W 0 1 Per il funzionamento a 1 5 Mbit s insieme a bus terminal RS 485 vedere capitolo Progettazione di reti B secondo EN 55022 CISPR 22 2kV secondo IEC 801 5 IEC 1000 4 5 Surge 2kV secondo IEC 801 4 IEC 1000 4 4 Burst 6kV Contact discharge secondo IEC 801 2 ESD IEC 1000 4 2 10 V m mit 80 modulazione di ampiezza a 1 kHz 80 MHz 1 GHz secondo IEC 801 3 ENV 50140 10 V m 50 rapporto d inserizione a 900 MHz secondo ENV 50204 10 V mit 80 modulazione di ampiezza a 1 kHz 10 kHz 80 MHz secondo IEC 801 6 ENV 50141 da0a60 C da 40a70 C max 95 a 25 C senza condensa 4 61 Componenti passivi per reti RS 485 Condizioni meccaniche Vibrazioni Funzionamento Urti Funzionamento Esecuzione costruttiva Dimensioni L x A x P inmm Lunghezza cavo di derivazione Peso compr cavo di derivazione 1 5 m Classe di protezione Marchio di prova 4 62 collaudato secondo DIN IEC 68 2 6 da 10 a 58 Hz ampiezza 0 075 mm da 58 a 500 Hz accelerazione 9 8 m s collaudato secondo DIN IEC 68 2 27 semisinusoidale 100 m s 16 ms 50 x 135 x 47 CE UL CSA Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 8 4 8 1 4 8 2 Collegamenti dei cavi Co
130. 970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti 3 3 1 Progettazione di topologie lineari e a stella con OLM Creazione della panoramica dell impianto La progettazione della rete PROFIBUS viene eseguita p es con SIMATIC STEP 7 La progettazione specifica per il bus inizia con la creazione della panora mica dell impianto nella finestra di configurazione dell hardware Configurazione HW di STEP 7 V5 0 ft Configurazione HW SIMATIC 300 DP Master Configurazione PROJECT PROFIBUS cc li ee NE M cros este Figura 3 3 Finestra Configurazione HW in STEP 7 V5 0 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 23 Progettazione di reti Impostazione delle propriet del PROFIBUS La finestra di immissione Propriet PROFIBUS permette di impostare Highest Station Address HSA indirizzo stazione pi alto la velocit di trasmissione e il profilo del bus Propriet PROFIBUS 1 5 Mbit s Standard Universale DP FMS Personalizzato Figura 3 4 Finestra di immissione Propriet PROFIBUS Reti PROFIBUS SIMATIC NET 3 24 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Immissione della configurazione dei cavi In Opzioni gt Cavi si trovano le caselle per impostare la configurazione dei cavi numero OLM lunghezza del cavo Figura 3 5 Finestra di immissione Op
131. 972 C1 22 02 Avvertenze relative al marchio CE In conformit a tale direttiva nostro obbligo ricordare che il prodotto contrasseg nato con il marchio CE destinato unicamente ad essere integrato in una mac china Prima della messa in servizio del prodotto finale necessario verificare che questo soddisfi i requisiti della direttiva 89 392 CEE Avvertenza per Australia SIMATIC NET OBT risponde ai requisiti della norma AS NZS 2064 Class A PROFIBUS Optical 8 2 Busterminal OBT C79000 G8972 C122 02 Bibliografia 9 1 2 Wrobel Christoph Herausgeber Tecnica di trasmissione ottica nella pratica industriale Huthig Buch Verlag GmbH Heidelberg 1994 G Mahlke P G ssig Cavi a fibre ottiche nozioni di base tecnica dei cavi 3 ristampa Berlin 1992 SIMATIC NET PROFIBUS basato sui seguenti standard norme e direttive 3 EN 50170 1 2 1996 General Purpose Field Communication System Volume 2 Physical Layer Specification and Service Definition Direttive PNO 4 5 6 ITI 8 9 PROFIBUS Optical Busterminal OBT Avvertenze di implementazione PROFIBUS relative al disegno DIN 19245 Parte 3 Versione 1 0 del 14 12 1995 EIA standard RS 485 aprile 1983 Standard for electrical characteristics of generators and receivers for use in balanced digital multipoint systems SIMATIC NET Manuale per reti PROFIBUS SIEMENS AG N di ordinazione 6GK19705AC10 0AA0
132. A20 0AA4 Edizione 2 05 2000 8 3 Componenti attivi per reti ottiche 8 2 Optical Link Module OLM SIEMENS PROFIBUS OLM System Figura 8 2 Optical Link Modul OLM Settore d impiego Il PROFIBUS OLM Optical Link Module della versione 3 permette di realizzare reti PROFIBUS con struttura lineare a stella e ad anello ridondante La velocit di trasmissione di una linea FO dipende in questo caso dalla distanza e pu essere compresa tra 9 6 kbit s e 12 Mbit s Le possibilit di impiego per OLM sono bus di impianti su base PROFIBUS colle gamenti in rete che si estendono su pi edifici con cavi in fibra ottica di vetro reti combinate con segmenti elettrici e ottici reti con grande estensione tunnel stra dali sistemi di guida del traffico reti con esigenze di elevata disponibilit reti ad anello ridondante ecc Reti PROFIBUS SIMATIC NET 8 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti ottiche Struttura Gli OLM sono disponibili con una o due interfacce FO per diversi tipi di cavi in fibra ottica e lcaviin fibra ottica di plastica 980 1000 um possono essere impiegati con lun ghezza di linea singola fino a 80 m Essi possono essere confezionati con con nettori BFOC anche sul luogo di installazione e cavi in fibra ottica di PCF 200 230 um possono essere impiegati con lun ghezza di linea singola fino a 400 m Essi sono disponibili gi confezionati con 4 connettori BFOC
133. A4 Edizione 2 05 2000 C 3 Installazione dei cavi di bus C 3 Protezione meccanica dei cavi di bus Protezione dei cavi di bus elettrici e ottici dispositivi di protezione meccanica hanno lo scopo di proteggere i cavi di bus da interruzioni o da danni meccanici Avvertenza Le misure qui descritte relative alla sicurezza meccanica sono valide sia per i cavi elettrici sia per quelli ottici Misure di sicurezza meccanica Per la protezione meccanica dei cavi di bus si raccomandano le seguenti misure e fuori da portacavi p es passerelle per cavi canalette a griglia i cavi di bus devono essere installati in un tubo di protezione p es PG 11 16 e in zone con carico meccanico i cavi di bus devono essere installati in tubi chiusi con rinforzi in alluminio altrimenti in tubi chiusi con rinforzi in plastica vedere figura C 1 e in caso di archi di 90 e di giunti negli edifici p es giunti di dilatazione con sentita un interruzione del tubo di protezione sempre che sia possibile esclu dere danni al cavo di bus dovuti p es a pezzi che cadono vedere figura C 2 e in zone di passaggio dell edificio e delle macchine e nelle zone di circolazione di carrelli di trasporto nelle quali i cavi potrebbero essere danneggiati i cavi di bus devono essere protetti con un tubo chiuso con rinforzo in acciaio o alluminio oppure in un alloggiamento di metallo per cavi Osservare le istruzioni per l installazione di ca
134. B Link e instabus EIB La registrazione della banca dati del DP EIB Link per il software di instabus EIB ETS 2 amp allegata al manuale DP EIB Per ulteriori informazioni dettagliate su questo argomento consultare il manuale del DP EIB Link Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 37 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Progettazione di reti 3 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 4 Progettazione di reti 3 1 Progettazione di reti elettriche Reti PROFIBUS Parametri Le reti PROFIBUS sono state sviluppate appositamente per l impiego in ambiente industriale e si distinguono per la loro elevata resistenza ai disturbi elettromagnetici e di conseguenza per una maggiore sicurezza dei dati Per garantire questa resi stenza durante la progettazione di reti elettriche necessario osservare alcune direttive Durante la progettazione di una rete elettrica necessario osservare i seguenti parametri e La velocit di trasmissione necessaria per l applicazione in una rete possibile utilizzare un unica velocit di trasmissione e numero necessario di nodi e Il tipo di componenti di rete necessari bus terminal connettori di bus cavi di connessione e cavi di bus che devono essere utilizzati e Le lunghezze di segmento desiderate e L ambiente elettromagnetico e meccanico delle linee dei cavi
135. BUS 3 Figura 2 10 Accoppiamento punto a multipunto con PROFIBUS ILM una rete parziale master 3 reti par ziali con slave Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 15 Topologie delle reti SIMATIC NET PROFIBUS 2 4 Topologie con PROFIBUS PA Topologia lineare e a stella La topologia di PROFIBUS PA possibile con struttura lineare e a stella Sistema SpliTConnect Lo SpliTConnect Tap diramazione a T permette la struttura di un segmento di bus con punto di allacciamento dei terminali di dati Inoltre lo SpliTConnect Tap pu essere collegato in cascata con ripartitori di allacciamento tramite SpliTConnect Coupler Con lo SpliTConnect terminator il tap pu essere ampliato con termina zione del segmento Stella Cavo jess PROFIBUS PA Diramazione a N Cavo di derivazione Ripartitore della diramazione a T Diramazione a T con terminazione di b pente Accoppiatore DP PA termina zione di bus in tegrata Allacciamento dei terminali di dati tramite allacciamento M12 DC 24V PROFIBUS DP Figura 2 11 Topologia lineare e a stella Alimentazione dei terminali di dati tramite PROFIBUS PA In caso di impiego di accoppiamento di bus DP PA i terminali di dati vengono ali mentati con il cavo di dati di PROFIBUS PA Struttura La somma di corrette di tutti i terminali di dati non deve superare la corrente di us cita massima dell accoppiatore DP PA La corrente massim
136. BUS tra due nodi in m Plastic Fiber Optic 50 1550 conduttori duplex Plastic Fiber Optic 50 1550 cavo standard PCF Fiber Optic 300 9300 Tabelle 7 8 Lunghezze di cavo ammesse in una rete OLM Cavo in fibra ottica Lunghezze massime del Calcolato su 1 rete SIMATIC NET cavo 32 nodi in m PROFIBUS tra due nodi in m Plastic Fiber Optic 50 1550 conduttori duplex Plastic Fiber Optic 80 2480 cavo standard PCF Fiber Optic 400 12400 cavo standard Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Funzionamento combinato Plastic Fiber Optic e PCF Fiber Optic Per uno sfruttamento ottimale delle diverse lunghezze dei cavi possono essere impiegati in modo combinato cavi Plastic Fiber Optic e PCF Fiber Optic p es collegamento tra slave DP e in modo decentrato con Plastic Fiber Optic di stanze lt 50 m e collegamento tra master DP e il primo slave DP della topologia lineare con PCF Fiber Optic distanza gt 50 m Posa di Plastic Fiber Optic cavi in fibra ottica di plastica possono essere confezionati e montati in proprio in modo semplice Per eseguire queste operazioni leggere le seguenti informazioni relative alle istruzioni di montaggio e alle regole di installazione nell appendice C Istruzioni di montaggio per Plastic Fiber Optic Le istruzioni di montaggio dettagliate con serie di foto per la confezione di cavi in fibra ot
137. Bus terminated per poter chiudere l estremit di un segmento RS 485 con l impedenza caratteristica e un cavo di derivazione confezionato con una lunghezza di 1 5 mo 3 m con connettore Sub D a 9 poli per il collegamento diretto ad un terminale di dati Terminazione dei cavi Il connettore Sub D viene innestato sul connettore femmina Sub D del terminale di dati e collegato a vite su un lato per la sicurezza meccanica Con la terminazione del cavo attivata posizione dell interruttore Bus terminated il bus terminal RS 485 del terminale di dati necessita di una corrente di max 5 mA con una tensione di alimentazione di 5 V tra i pin 5 e 6 del connettore Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 49 Componenti passivi per reti RS 485 Tabella 4 10 Assegnazione dei contatti del connettore Sub D B RXD TXD P Cavo dati B Receive Transmit Data P M5V2 DGND Potenziale di riferimento dati Data Ground 6 P5V2 VP Tensione di alimentazione 5 V voltaggio positivo 8 A RXD TXD N Cavo dati A Receive Transmit Data N C a e Reti PROFIBUS SIMATIC NET 4 50 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Interfaccia PG integrata Il bus terminal RS 485 con interfaccia PG integrata vedere figura 4 28 riporta sul frontalino un connettore femmina Sub D a 9 poli supplementare per l allacciamento p es di un dispositivo di programmazione mediante un cavo
138. C_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 743 Componenti passivi per reti ottiche Dati tecnici Le tabelle 7 4 e 7 5 riportano una panoramica dei dati tecnici di tutti i cavi in fibra ottica di vetro SIMATIC NET Tabella 7 4 Dati tecnici del cavo INDOOR Fiber Optic e del cavo Fiber Optic standard Tipo di cavo Settore d impiego Fiber Optic Cavo standard Cavo universale per l impiego all interno di edifici e all aperto INDOOR Fiber Optic Cavo per l installazione all in terno di edifici Cavo calpestabile esente da alo geni e difficilmente infiammabile per l impiego all interno di edifici Fornitura Confezionato con 4 connettori Confezionato con 4 connettori BFOC con lunghezze definite e a BFOC con lunghezze stabilite metraggio Tipo di cavo AT VYY 2G62 5 125 I VHH 2G62 5 125 Sigla identificativa a norma 3 1B200 0 8F600 F 3 2B200 0 9F600 F TB3 FRNC OR Tipo di fibra Fibra a gradiente d indice Fibra a gradiente d indice multimode 62 5 125 um multimode 62 5 125 um Attenuazione a 850 nm lt 3 1 dB km lt 3 2 dB km Attenuazione a 1300 nm lt 0 8 dB km lt 0 9 dB km Larghezza banda modale a 850 nm 200 MHz km 200 MHz km a 1300 nm 600 MHz km 600 MHz km Numero di fibre 2 2 Struttura del cavo Cavo sezionabile per esterno Cavo sezionabile per l impiego in edifici Tipo di conduttore Conduttore compatto Conduttore fisso Materiali ele
139. Cable This document contains information in English SIEMENS AG 1999 Page 1 Subject to change Standard Cable Dated 08 99 SIMATIC NET PROFIBUS PCF Fiber Optic Standard Cable We have checked the contents of this manual for The reproduction transmission or use of this document agreement with the tools described Since or its contents is not permitted without express written deviations cannot be precluded entirely we cannot authority Offenders will be liable for damages All rights guarantee full agreement However the data in this including rights created by patent grant or registration of manual are reviewed regularly and any necessary a utility or design are reserved corrections included in subsequent editions Suggestions for improvement are welcome Technical data subject to change Copyright Siemens AG 1999 All Rights Reserved Note We would point out that the contents of this product documentation shall not become a part of or modify any prior or existing agreement commitment or legal relationship The Purchase Agreement contains the complete and exclusive obligations of Siemens Any statements contained in this documentation do not create new warranties or restrict the existing warranty We would further point out that for reasons of clarity these operating instructions cannot deal with every possible problem arising from the use of this device Should you require further information or if any special problems a
140. D TxD N and RxD TxD P are indirect coupled functional separation Fig 9 Electrical port assignment of Sub D sockets within SELV restrictions Only use shielded and twisted pair wiring as a RS 485 bus line as described in the manual SIMATIC NET PROFIBUS networks Do not exceed the segment lengths given there Use a PROFIBUS bus connector plug to connect the RS 485 bus segment If the module is at the beginning or end of a bus segment this connector must have an activated bus terminal resistor combination All PROFIBUS bus connector plugs in a network must be securely screwed onto the RS 485 interfaces Attaching or removing the bus connector plugs inadequately attached bus connector plugs or loose bus wires within the plug can lead to malfunctions in the optical and electrical networks Attach or remove the RS 485 bus connector plug quickly and without twisting them Remove the RS 485 bus line from the OLM if a device is not connected to the other end or there is an OLM which has been disconnected from the power supply The open line otherwise acts as an antenna and can cause inter ference When connecting a RS 485 bus line to the PROFIBUS OLM in an active network keep to the following sequence in order to avoid interference 1 Place the RS 485 bus connector plug onto the device which is to be connected e g to a programming device and screw it on tightly 2 Attach the RS 485 bus connector plug to the PROFIBUS OLM quickly
141. D a 9 poli Le due estremit del cavo sono previste con combinazioni di resistenza non disattivabili Questo cavo disponibile con lunghezze di 1 5 e 3 m Figura 4 34 Cavo di connessione 830 1T Funzione Il cavo di connessione 830 1T collega e l interfaccia elettrica del Optical Link Module OLM OBT all interfaccia PROFI BUS di un terminale di dati Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 65 Componenti passivi per reti RS 485 Avvertenza A causa della combinazione di resistenze integrata il cavo di connessione 830 1T non pu essere impiegato come cavo di derivazione p es per allacciamento PG su un segmento PROFIBUS Tabelle 4 11 Dati per l ordinazione del cavo di connessione 830 IT SIMATIC NET Dati per l ordinazione Cavo di connessione 830 1T SIMATIC NET per PROFIBUS per l allacciamento di terminali di dati a OLM e OBT preconfezionati con 2 connettori Sub D terminato su entrambi i lati con cavo a 9 poli 1 5 m 3m 6XV1830 1CH15 6XV1830 1CH30 Reti PROFIBUS SIMATIC NET 4 66 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 9 2 Cavo di connessione 830 2 Settore d impiego Il cavo di connessione 830 2 un cavo confezionato per l allacciamento rapido ed economico di nodi PROFIBUS p es HMI ad apparecchi di automazione per velo cit di trasmissione fino a12 Mbit s Struttura Il cavo di connessione 830 2 composto dal cav
142. EMENS AG N di ordinazione 6ES7498 8AA00 8AB0 Edizione 1 SIMATIC Controllore programmabile S7 300 Installazione dati CPU Manuale SIEMENS AG compreso nel Pacchetto di manuali S7 300 M7 300 N di ordinazione 6ES7 398 8AA02 8AA0 SIMATIC Controllore programmabile S7 400 M7 400 Configurazione manuale di installazione SIEMENS AG compreso nel Pacchetto di manuali S7 400 M7 400 N di ordinazione 6ES7 398 8AA02 8AA0 SIMATIC Accoppiamento di bus DP PA Manuale SIEMENS AG N di ordinazione 6ES7157 0AA00 0AA0 Edizione 2 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Bibliografia 14 SIMATIC Sistemi di automazione S7 300 M7 300 ET 200M Unita periferica EX Manuale di riferimento SIEMENS AG compreso nel Manuale per S7 300 in aree EXCi Direttive di montag gio e fogli dati dell unit N di ordinazione 6ES7 398 8RA00 8AA0 15 SIMATIC Sistema di automazione S7 300 M7 300 ET 200M Nozioni di base protezione contro esplosioni Manuale SIEMENS AG compreso nel Manuale per S7 300 in aree EXCi Direttive di montag gio e fogli dati dell unit N di ordinazione 6ES7 398 8RA00 8AA0 Ulteriori informazioni Ulteriori informazioni relative agli argomenti sicurezza intrinseca e protezione con tro esplosioni sono riportate nei seguenti manuali e Manuale Sistemi di automazione S7 300 M7 300 ET 200M Unit periferiche Ex N di ordinazione 6ES7 398 8RA00 8AA0 e Controllo
143. I Bus terminal ottico Settore d impiego 8 2 L OBT Optical Bus Terminal permette di allacciare un nodo PROFIBUS singolo senza interfaccia ottica o un segmento PROFIBUS RS 485 con un massimo di 31 nodi al PROFIBUS ottico e consente agli apparecchi DP di usufruire dei van taggi della trasmissione ottica dei dati Un nodo PROFIBUS DP singolo viene allacciato con la proprioa interfaccia RS 485 tramite un cavo di connessione con terminazione su entrambi i lati p es cavo di connessione 830 1T all interfacia RS 485 dell OBT L OBT viene collegato nella linea ottica con due interfacce ottiche AI OBT possibile allacciare i seguenti mezzi trasmissivi e Cavo in fibra ottica di plastica con lunghzza singola di spezzone fino a 50 m Questi cavi possono essere facilmente confezionati sul luogo di installazione con 2 x 2 connettori simplex e Cavi in fibra ottica di PCF con lunghezza singola di spezzone fino a 300 m Questi cavi dopo disponibili gi confezionati Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti ottiche Struttura L OBT munito di un contenitore compatto in plastica Esso adatto sia per il montaggio su una guida ad U sia per il montaggio a parete grazie a due fori pas santi L OBT dispone dei seguenti allacciamenti e Connettore femmina Sub D a 9 poli per l allacciamento di un segmento PROFI BUS RS 485 con nodi come p es dispositivo di prog
144. IBUS OBT non viene montato su una guida ad U messa a terra ne cessario installare un cavo di terra possibilmente corto con una sezione di 2 5 mm dal morsetto PE alla possibilit di terra pi vicina PROFIBUS Optical Busterminal OBT 5 5 C79000 G8972 C1 22 02 Messa in funzione Allacciamento dei cavi di bus ottici A B C D Figura 5 4 Vista del lato del modulo con i canali ottici CH2 e CH3 A CH2 ricevitore ottico B CH2 trasmettitore ottico C CH3 ricevitore ottico D CH3 trasmettitore ottico e Collegare i singoli PROFIBUS OBT con un cavo FO duplex confezionato con due coppie di connettori simplex e Fare attenzione che siano collegati rispettivamente un ingresso ottico con un u scita ottica collegamento incrociato e Provvedere ad uno scarico di tiro sufficiente del cavo FO e osservare i raggi di curvatura minima del cavo FO e Chiudere i connettori femmina del cavo FO non utilizzati con i tappi di plastica allegati La penetrazione di luce dell ambiente in particolare in caso di ambiente con elevata luminosit pu disturbare la rete PROFIBUS e Rispettare la lunghezza minima e massima del cavo FO e i tipi di fibra ammessi specificati nella tabella 1 e nei dati tecnici e Far attenzione a non far penetrare polvere nei componenti ottici La penetra zione di polvere pu distruggere completamente i componenti ottici e La fibra ottica deve aderire alla superficie del connettore PROFIBUS
145. ILM can be adjusted continuously to align it to the partner station in the horizontal axis To add greater stability it is advisable to use toothed washers with the bolts It is also advisable to install the module at the edge of the mounting surface so that the cables lead to and from the module unhindered and to make sure that there is no reflection of the sender to its own receiver caused by the installation site itself 35 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 8 1 Connecting the Electrical RS 485 Bus Cables For the RS 485 bus cable use only shielded twisted pair cables with an outer diameter of 7 5 to 10 mm Appendix B lists the electrical parameters of cable types recommended in compliance with the standard Make sure that you connect the same cores green or red uniformly to all bus terminals of a cable section either terminal A or terminal B The following are recommended for field bus networks Terminal A Green core Terminal B Red core Do not connect any RS 485 LAN cables that are laid completely or partly outside buildings without first protecting the network using a suitable surge voltage protector Otherwise lightning strikes in the area can destroy the PROFIBUS ILM or other network components Connect the RS 485 LAN cable to the terminal block as shown in Figure 16 The terminals marked A or B are electrically identical o o i Terminalbiock ee Bare wire approx 8 mm AB Core insula
146. IP switch Optical channel Optical source 21 LEDs 28 dBmW Wavelength 860 nm to 880 nm Distance between two ILMs maximum 15 m in the optical axis 12 mat 2 m distance from the optical axis Signaling contacts Limit values of the relay maximum switching power Maximum switching voltage Maximum switching current Table 3 Technical Specifications of the PROFIBUS ILM Copyright by Siemens 46 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Electromagnetic Compatibility EMC Noise emission Immunity to static discharge Immunity to high frequency noise Immunity to disturbances on the cable burst Immunity to disturbances on the cable surge Limit Class B EN 55022 On shield connection and casing 8 kV contact di scharge IEC 1000 4 2 10 V m at 80 amplitude modulation with 1 kHz 80 MHz 1 GHz ENV 50140 IEC 1000 4 3 10V m at 50 duty cycle at 900 MHz ENV 50 204 10 V m at 80 amplitude modulation at 1 kHz 10 kHz 80 MHz ENV 50141 On power supply cables and shielded RS 485 LAN ca bles 2 kV IEC 1000 4 4 On power supply cables 1 kV balanced On shielded RS 485 cables 2 kV unbalanced IEC 1000 4 5 47 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 Safety VDE specifications UL CSA approval Climatic environmental conditions Ambient temperature Storage temperature Relative humidity Mechanical envir
147. Lines with two optical fibers are used to create the fiber links for these network topologies If a malfunction e g a break in a fiber line makes a high degree of field bus network fail safety necessary the availability of the network can be increased using a redundant network configuration Please note Single terminals or entire PROFIBUS segments with max 31 subscribers can be connected to the electrical interface of the PROFIBUS OLM In areas with a high EMC incidence only lay optical fiber lines in order to exclude the possibility of EMC affecting the whole network Optically only OLMs of the same type can be connected together OLM P11 with OLM P12 OLM G11 with OLM G12 and OLM G12 EEC OLM G11 1300 with OLM G12 1300 Optical ports which are connected by optical fiber must be set to the same operating mode Junctions between different OLM types are only possible via the RS485 interface OLM G12 EEC can be used everywhere in those network topologies described below in which a OLM G12 can also be used 3 1 Line topology Terminal unit Terminal unit Terminal unit Terminal unit bus segment bus segment bus segment bus segment eee a RS 485 bus line Optical fiber ern CH 1 E 0222002707 i CH1 m CH1 gm CH 1 OLM P11 OLM P12 OLM P12 OLM P11 OLM G11 1300 OLM G12 1300 OLM G12 1300 OLM G11 1300 CH2 CH 2 CH 3 CH 2 CH 3 CH 2
148. MATIC BASIC Hotline SIMATIC BASIC Hotline Ora loc Lu Ve dalle 8 00 alle Ora loc Lu Ve dalle 8 00 alle 18 00 17 00 Telefono 49 911 895 7000 Telefono 1 423 461 2522 Fax 49 911 895 7002 Fax 1 423 461 2231 E mail simatic support E mail simatic hotline nbgm siemens de sea siemens com Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 F Singapore Ne AR b Singapore SIMATIC BASIC Hotline Ora loc Lu Ve dalle 8 30 alle 17 30 Telefono 65 740 7000 Fax 65 740 7001 E mail simatic hotline sae siemens com sg J 1 SIMATIC NET Supporto e training SIMATIC Premium Hotline a pagamento solo con SIMATIC Card Orario Lu Ve dalle 0 00 alle 24 00 Telefono 49 911 895 7777 Fax 49 911 895 7001 Servizi SIMATIC Customer Support Online Con i servizi Online il SIMATIC Customer Support offre illimitate informazioni sup plementari sui prodotti SIMATIC e Informazioni attuali generali possono essere richiamate in Internet al sito tramite Fax Polling N 08765 93 02 77 95 00 e Informazioni attuali sul pdototto con download che possono essere utili in caso di impiego possono essere richiamati in Internet al sito http www ad siemens de csi net tramite Bulletin Board System BBS a Norimberga SIMATIC Customer Support Mailbox al numero 49 911 895 7100 Per l attivazione del mailbox utilizzare un modem fino a V 34 28 8 kB
149. N di ordinazione 6GK1500 3AA00 Direttiva CE EMC 89 336 CEE Il prodotto sopracitato soddisfa i requisiti della direttiva CE 89 336 CEE Compatibilit elettromagnetica nel settore industriale Settore d impiego Requisiti l Emissioni di disturbo Immunit ai disturbi Industria EN 50081 2 1993 EN 50082 2 1995 Dichiarazione di conformit La dichiarazione di comformit CE tenuta a disposizione delle autorit compe tenti conformemente alla direttiva sopracitata presso Siemens Aktiengesellschaft Bereich Automatisierungstechnik Industrielle Kommunikation A amp D PT2 Postfach 4848 D 90327 N rnberg Osservanza delle direttive di montaggio Il prodotto soddisfa i requisiti richiesti se nella fase di installazione e durante il funzionamento vengono rispettate le direttive di montaggio descritte nella documentazione Optical Bus Terminal PROFIBUS OBT Le potenze radianti accessibili dei LED di trasmissione impiegati corrispondono alla classe 1 secondo EN 60825 1 1994 A11 1996 e IEC 60825 1 1993 compreso Amendment 1 1997 LED classe 1 Le potenze radianti accessibili aprendo appositamente inavvertitamente il cavo a fibre ottiche corrispondono al grado di pericolosit 1 secondo EN 60825 2 1994 e 60825 2 1993 Avvertenze per il construttore Ai sensi dell articolo 4 2 della direttiva CE 89 392 CEE in materia di macchine il prodotto un componente PROFIBUS Optical Busterminal OBT 8 1 C79000 G8
150. N 46228 Utilizzare solo copicorda di materiale con propriet di contatto a stabilit permanente p es rame con superficie stagnata non alluminio Il connettore di bus 6ES7 972 0BA30 0XA0 non pu essere allacciato ai condut tori a trefoli Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 1 6 Conduttore interno in rame massiccio Protezione di isolamento in PE cellulato Guaina esterna di PE Figura 4 6 FC Underground Cable cavo di posa interrata Guaina interna di PVC Schermo a maglia in rame Foglio di schermatura in alluminio Foglio in materiale sintetico Materiale di riempimento Principio di struttura del cavo di posa interrata Cavo di posa interrata FC 6GK1 830 3FH10 Propriet Il cavo di posa interrata FC 6GK1 830 3FH10 soddisfa i requisiti di EN 50170 tipo di cavo A con conduttori in rame massiccio AWG 22 La struttura interna corri sponde a quella del cavo di bus standard le propriet elettriche sono identiche Il cavo rivestito con una guaina esterna supplementare di PE La guarnizione esterna e quella interna sono incollate tra loro in modo che il cavo di posa interrata FC possa essere confezionato direttamente con tutti i connettori di allacciamento SIMATIC NET PROFIBUS dopo aver tolto la guaina esterna Dopo aver tolto la guaina esterna la struttura del cavo permette l impiego del FastConnect FC Stripping Tool
151. NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 TECNICA DI MISURA PROFIBUS Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 A A 1 TECNICA DI MISURA PROFIBUS A 1 A 1 1 A 1 2 A 1 3 A 2 Dispositivo di test hardware BT 200 per PROFIBUS DP Possibilit di impiego Il dispositivo di test HW BT 200 per PROFIBUS DP serve come tool di installazione di messa in servizio e di service A causa delle svariate possibilit di impiego questo tool destinato sia al personale addetto all installazione di reti PROFIBUS sia al personale addetto alla messa in funzione e al service Inoltre esso semplifica la stesura del protocollo di collaudo Settore d impiego Con il dispositivo di test BT200 possibile controllare la linea PROFIBUS durante la fase di installazione Gli errori di installazione vengono localizzati in modo sem plice e rapido anche da personale addetto all installazione senza conoscenze spe cifiche PROFIBUS Ancora prima della messa in funzione dell impianto il BT200 permette di eseguire un test dei driver RS 485 degli slave PROFIBUS DP Una rappresentazione degli slave raffigurabili a bus ultimato possibile senza nessun master collegato a PROFIBUS DP In questo modo possibile controllare il funzio namento dei singoli segmenti di bus riducendo cos i tempi per la messa in fun zione In caso di guasto queste due ultime funzioni di test forniscono un aiuto per localizzare i guasti e per
152. Necessit di una misurazione conclusiva L attenuazione complessiva di una linea FO in particolare l influenza di punti di collegamento necessari pu essere calcolata solo approssimativamente durante la pianificazione della linea Errori di elaborazione sui punti di collegamento e solle citazioni eccessive dei cavi durante l inserimento possono comportare un supera mento dell attenuazione della linea reale rispetto ai valori calcolati La sicurezza di funzionamento e la riserva di potenza della linea FO viene garantita solo da una misurazione conclusiva dell attenuazione Si raccomanda di sottoporre a questo test conclusivo ogni linea di trasmissione FO confezionata in proprio e di documen tare i risultati in un protocollo di collaudo Attenuazione Attenuazione definita come perdita ottica di potenza in decibel dB nelle reti otti che Tutti i componenti del sistema come cavo connettore sdoppiamenti accop piamenti ecc contribuiscono all attenuazione complessiva di una linea e di conse guenza anche dell intera rete Per poter calcolare questa attenuazione necessario impiegare misuratori FO dopo l installazione Per la misurazione deve essere utilizzata luce con la stessa lunghezza d onda di quella impiegata nel si stema ottico di trasmissione Metodi di misura Principalmente vengono utilizzati due metodi di misura 1 Metodo di attraversamento di raggi luminosi 2 Reflettometro OTDR Un altro utensile indispe
153. S ILM on the master network segment Copyright by Siemens 14 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Infrared transmission link 1 PROFIBUS 0 5to15m master network segment al ILM gt PROFIBUS slave network segment 1 Optical isolation between the infra red transmission links Infrared transmission link 1 0 5 to 15m PROFIBUS slave network segment 2 Figure 4 Link Between Several Slave Network Segments and One Master Network Segment 15 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 5 2 2 _Point to Multipoint Link Instead of the multiple use of point to point links the point to multipoint link can also be used Optical isolation between the infrared transmission links is not necessary If the configuration is correct only one slave node responds to the request of a master node and because there is only one PROFIBUS ILM on the master network segment there are no synchronization problems with the response The advantage of this arrangement is that with n slave segments only n 1 PROFIBUS ILMs are required The disadvantages of this arrangement are not only the restrictions in the arrangement of the slave PROFIBUS ILMs to a solid angle of 10 degrees but also from the point of view of th
154. SIEMENS SIMATIC NET Reti PROFIBUS Manuale 6GK1970 5CA20 0AA4 C79000 G8972 C124 05 2000 Edizione 2 DI m a v D O m w ao N opologie delle reti SIMATIC NET PROFIBUS W gettazione di reti v e Ls omponenti passivi per reti RS 485 dI omponenti attivi per reti RS 485 omponenti passivi per PROFIBUS PA omponenti passivi per reti ottiche omponenti attivi per reti ottiche omponenti attivi per reti senza fili ecnica di misura PROFIBUS Protezione contro fulmini e sovratensioni per avi di bus che si estendono in pi edifici Installazione dei cavi di bus Istruzioni di montaggio per SIMATIC NET PROFI BUS Plastic Fiber Optic con connettori Simplex o onnettori BFOC e attrezzo di inserimento per il D avo standard Fiber Optic m Installazione di componenti di rete in un armadio Disegni in scala Istruzioni per l uso ILM OLM OBT Informazioni generali Bibliografia U gt e Z m vw c a Avvertenze tecniche di sicurezza Il presente manuale contiene avvertenze tecniche relative alla sicurezza delle persone e alla prevenzione di danni materiali che vanno assolutamente osservate Le avvertenze sono contrassegnate da un trian golo e a seconda del grado di pericolo rappresentate nel modo seguente Pericolo di morte gt persone e ingenti danni materiali
155. T PROFIBUS compatibili Inoltre assolutamente necessario rispettare le prescrizioni di installazione contenute nel presente manuale e nei ma nuali dei sistemi di automazione collegati in rete C 4 1 Provvedimenti di protezione contro tensioni di disturbo Informazioni generali Spesso i provvedimenti per la soppressione di tensioni di disturbo vengono adottati solo quando il controllo gi in funzione e la ricezione di un segnale utile distur bata Il tempo necessario per provvedimenti di questo tipo p es contattori spe ciali pu spesso essere notevolmente ridotto osservando i seguenti punti gi du rante la realizzazione dell impianto di automazione e collegamento a terra di tutte le parti metalliche inattive e schermaggio degli apparecchi e dei cavi e disposizione adatta degli apparecchi e dei cavi e misure speciali antidisturbi Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 7 Installazione dei cavi di bus C 4 2 Montaggio e collegamento a terra delle parti metalliche inattive Collegamento a terra C 4 3 Collegare con buona condizione e poteziale di terra tutte le parti metalliche inattive nelle immediate vicinanze dei componenti di automazione e dei cavi di bus con duttore di protezione Queste sono tutte le parti metalliche di armadi parti della costruzione e della macchina ecc che non hanno alcuna funzione di conduzione elettrica nell impianto di automazione Il collegamento di
156. Table 3b Constants for calculating the slot time at DP FMS universal and DP with S5 95U redundant optical ring The calculation of the slot time only takes into consideration the optical network and the connection of bus sub scribers to the OLM via an RS 485 bus segment with a respctive length of max 20 m Longer RS 485 bus segments must be allowed for by adding them to the Length orf Note When the slot time is configured with a too small value the OLM will through it s fault function and fault indications indicate such The System LED will blink red green 1 Using the OLM G11 1300 and OLM G12 1300 at data rates of 12 MBit s 6 MBit s 3 MBit s and 1 5 MBit s the minimum slot times according to the following table must be met Data rate Minimum slot time 12 MBit s 3800 tg 6 MBit s 2000 tgi 3 MBit s 1000 tgi 1 5 MBit s 530 ter Table 4 Minimum slot time on OLM G11 1300 and OLM G12 1300 Use the values from Table 4 if the calculated slot time is smaller than the minimum slot time indicated in the table 30 Version 1 1 8 00 7 Technical Data 7 Technical Data OLM Module P11 G11 G11 1300 P12 G12 G12 1300 G12 EEC Voltage power supply Operating voltage 18 V to 32 V DC typ 24 V redundant inputs uncoupled safety extra low voltage indirect coupled Current consumption max 200 MA Output voltage current for terminal resistors Pin 6 Sub D socket 5V 5 1
157. Vervielf ltigung dieser Unterlage Verwertung und Mitteilung ihres Inhalts ist nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen verpflichten zu Schadensersatz Alle Rechte vorbehalten insbesondere f r den Fall der Patenterteilung oder GM Eintragung Copyright Siemens AG 1998 All Rights Reserved We have checked the contents of this manual for agreement with the hardware described Since deviations cannot be precluded entirely we cannot guarantee full agreement However the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions Suggestions for improvement are welcome Technical data subject to change The reproduction transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility or design are reserved Copyright Siemens AG 1998 All Rights Reserved Order Number SIMATIC NET PROFIBUS ILM 6GK1 503 0AA00 Description and Operating Instructions 6ZB5530 3AC30 0BA1 Siemens AG Infoservice Abteilung A amp D Z 533 Postfach 23 48 90713 Furth Germany 1 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 Note We would point out that the contents of this product documentation shall not become a part of or modify any prior or existing agreement commitment or legal
158. a di uscita limita in que sto modo il numero di apparecchiature da campo allacciabile a PROFIBUS PA Reti PROFIBUS SIMATIC NET 2 16 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS PROFIBUS PA Accoppiatore DP PA Ex i 6ES7 157 0AD00 0XA0 Inax Tipo di protezione da scintille EEx ia Il C Imax 90 mA Accoppiatore DP PA Ex i 6ES7 157 0AD80 0XAO Apparecchiature da campo 1 2 3 an Tipo di protezione DE 24V da scintille EEx ib Il C PROFIBUS DP E Imax lt 110 MA Area protetta da esplosioni PROFIBUS PA Accoppiatore DP PA 6ES7 157 0ACx0 0XA0 Imax 400 mA Apparecchiature da campo 1 2 3 M PROFIBUS DP Figura 2 12 Alimentazione remota di apparecchiature da campo in aree Ex e non Ex Ampliamento Se la corrente massima di uscita dell accoppiatore DP PA viene superata neces sario impiegare un ulteriore accoppiatore DP PA Somma dei cavi La somma dei cavi la somma del cavo principale e di tutti i cavi di derivazione Per un cavo standard PROFIBUS PA con una sezione di 0 8 mm la lunghezza massima la somma dei cavi con numero massimo di apparecchiatura da campo e posizione svantaggiosa sull estremita del cavo e 560 m per cacoppiatore DP PA 6ES7 157 0AC00 0XA0 e 680 m per accoppiatore DP PA 6ES7 157 0AD80 0XA0 e 790 m per accoppiatore DP PA Ex i 6ES7 157 0AD00 0XA0 Cavo di derivazione La lunghe
159. a due nodi in m Plastic Fiber Optic 50 1550 conduttori duplex Plastic Fiber Optic 50 1550 cavo standard PCF Fiber Optic 300 9300 Tabella 3 8 Lunghezze di cavo ammesse in una rete OLM Cavo in fibra ottica Lunghezze massime del Calcolato su 1 rete cavo standard SIMATIC NET cavo 32 nodi in m PROFIBUS tra due nodi in m Plastic Fiber Optic 50 1550 conduttori duplex Plastic Fiber Optic 80 2480 cavo standard PCF Fiber Optic 400 12400 Avvertenza e Una linea ottica pu comprendere al massimo 32 interfacce otti che in successione e Diverse linee costituite da un massimo di 32 interfacce ottiche in tegrate possono essere collegate tramite OBT repeater ottico e Nelle reti ottiche con struttura lineare a stella ad anello che contengono solo OLM il numero di OLM limitato a 122 e numero di tutti i componenti ottici interfacce integrate OBT OLM nella rete ottica PROFIBUS deve essere specificato sotto Numero OLM OBT nel tool di progettazione vedere capi tolo 3 3 componenti non devono essere pi di 122 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Funzionamento combinato Plastic Fiber Optic e PCF Fiber Optic 3 2 4 Esempi di 3 18 Per uno sfruttamento ottimale delle diverse lunghezze dei cavi possono essere impiegati in modo combinato cavi Plastic Fiber Optic e PCF Fiber Optic p es c
160. a flat solid surface Repeat the procedure with the second connector and clean the surfaces of the plug with a clean cloth SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors Assembling the Plug Adapter only with integrated optical interfaces such as the IM 153 2 FO and IM 467 FO Insert the connector of the orange cord with the direction arrows into the holder whose triangle arrow head symbol points in the same direction Caution The hinge of the simplex connector must be towards the center of the plug adapter Insert the connector with the black cord Close the upper half of the plug adapter into the free holder Caution Once again the hinge of the simplex connector must be towards the center of the plug adapter The two hinges must not jut out of the plug adapter Marking of the SIMATIC NET PROFIBUS plastic fiber optic standard cable for installation without plug adapters To help you connect up the cable correctly the standard cable has arrow markings on the orange cord This helps to make sure that you attach one end of a cord to the transmitter and the other to a receiver crossed over cords First connect the orange cord The black cord is then connected to the e If the arrow on the orange cord is free socket of the same FO interface pointing out of the cable as shown in the figure connect this cord to the receiver The receiver is identified by an
161. a forza di tiro e pi cicli di curvatura gt 50 mm gt 150 mm gt 75mm con forza di tiro solo sul lato lato largo Condizioni ambientali ammesse e Temperatura di trasporto di magazzinaggio e Temperatura di posa e Temperatura d esercizio da 30 Ca 70 C da 0 C a 50 C da 30 Ca 70 C da 30 C a 70 C da 0 C a 50 C da 30 Ca 70 C da 30 Ca 70 C da 5 C a 50 C da 20 Ca 70 C Resistenza a e olio minerale ASTM N 2 grasso minerale o acqua e radiazioni UV con limitazione non resistente a ra diazioni UV con limitazione con limitazione con limitazione con limitazione Resistente alla fiamma resistente in base al testo VW 1 secondo UL 1581 Dimensioni esterne 2 2 4 4mm Diametro Diametro 0 01 mm 7 8 0 3 mm 4 7 0 3 mm Peso 7 8 kg km 65 kg km 22 kg km 1 Per domande relative a impieghi specifici rivolgersi al consulente Siemens Reti PROFIBUS SIMATIC NET 7 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche 7 2 1 Plastic Fiber Optic conduttori duplex 4 4 mm Nucleo Cladding Guaina Figura 7 1 Principio di struttura del cavo in fibra ottica di plastica con conduttori duplex 6XV1821 2AN50 Cavi in fibra ottica di plastica con coduttori duplex 6XV1821 2AN50 Il cavo in fibra ottica di plastica con conduttori duplex 6XV1821 2AN50 un un conduttore doppio piatto c
162. a i due ILM deve esserci un collegamento a vista senza ostacoli Gli ILM sono adatti per velocit di trasmissione da 9 6 kbit s a 1 5 Mbit s Collegamento punto a punto Per un collegamento punto a punto vengono posizionati uno di fronte all altro 2 ILM in modo che ogni ILM si trovi nel facio conico di raggi infrarossi dell ILM opposto La distanza massima deve essere di 15 m Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 13 Topologie delle reti SIMATIC NET PROFIBUS Master OP 25 Master PG PC OP Master S7 400 2 Linea di trasmissione a raggi infrarossi 0 5 15m Slave ET 200M E K Segmento di rete Segmento di rete master PROFIBUS slave PROFIBUS Resistenza terminale attivata 2 cavo di bus PROFIBUS Figura 2 9 Accoppiamento punto a punto con due PROFIBUS ILM La figura 2 9 descrive la struttura caratteristica di una rete di comunicazione PROFIBUS con nodi master e slave e una linea di trasmissione a raggi infrarossi con due PROFIBUS ILM La linea di trasmissione a raggi infrarossi realizzata come accoppiamento punto a punto ad entrambi i PROFIBUS ILM In questo caso i due PROFIBUS ILM sostituiscono un collegamento di cavi tra entrambi i seg menti della rete per i quali va osservato che nel segmento di rete slave sono am messi solo nodi sla
163. a strutturazione dell area I O dello slave PROFIBUS e la definizione del numero di oggetti di dati E B con il quale comunica il master DP viene eseguita con i profili impostabili In tutto sono disponibili 5 profili diversi che permettono all utente di adattare nel modo migliore il DP E B Link alla relativa applicazione e di utilizzare in modo ottimale le risorse di memoria del master DP La progettazione vale a dire l impostazione di un profilo viene eseguita tramite PROFIBUS p es con STEP 7 o COM PROFIBUS Il numero di oggetti di dati predefinito dal profilo impostato pu essere assegnato ai componenti instabus EIB desiderati con il software di progettazione instabus EIB ETS 2 A causa delle registrazioni della banca dati del DP EIB Link il software di progetta zione instabus EIB ETS 2 in grado di visualizzare all utente il numero del relativo tipo di dati degli oggetti di dati instabus E B validi In questo modo possibile un assegnazione semplice e senza errori Dopo la conclusione della progettazione il master PROFIBUS DP pu accedere agli oggetti di dati instabus E B sia per scrittura sia per lettura Progettazione La progettazione come slave DP pu essere eseguita p es con il tool standard STEP 7 o COM PROFIBUS e su instabus EIB con il software di progettazione ETS 2 e DP AI manuale allegato un file GSD L impostazione dell indirizzo slave DP viene eseguito con l interruttore di codifica riportato sul DP EI
164. a trasmissione su distanze molto grandi viene impiegata la fibra mono mode fibra singlemode Sulla fibra monomode possono essere comandati solo elementi di trasmissione e di ricezione e connessioni speciali di elevata qualit In combinazione con OLM G11 1300 o OLM G12 1300 possibile coprire di stanze fino a 15 km Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Struttura del cavo Per applicazioni speciali disponibile una gran quantit di variazioni della struttura del cavo p es Conduttori a fascio cavi con conduttori cavi nei quali vengono inserite diverse fibre Cavi con protezione antiroditori per la posa diretta nel terreno Cavi esenti da alogeni p es per l impiego in tubi della ferrovia sotterranea Cavi ibridi con conduttori in fibra ottica e conduttori in rame in una guaina Cavi certificati p es per l impiego su navi Fonte di riferimento Se i cavi FO dovessero essere necessari per un impiego speciale rivolgersi al consulente Siemens locale vedere appendice 1 2 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 25 Componenti passivi per reti ottiche 7 4 Connettori per cavi FO Avvertenza I connettori per cavi FO sono sensibili a sporco e sollecitazione meccanica della superficie frontale Proteggere allacciamenti aperti con i cappucci parapolvere forniti 7 4 1 Connettore per cavi in fibra ottica di plastica c
165. aiuto di capicorda 0 25 mm secondo DIN 46228 Il connettore di bus 6ES7 972 OBA30 0XA0 non pu essere allacciato Il cavo non adatto per l impiego del FastConnect FC Stripping Tool Reti PROFIBUS SIMATIC NET 4 18 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Propriet Il cavo di bus per strutture sospese a festoni presenta le seguenti propriet e il materiale della guaina contiene alogeni PVC e resistente con limitazioni a grassi e oli minerali e resistente a radiazioni UV e piccoli raggi di curvatura per la posa e il funzionamento e la resistenza del conduttore e l attenuazione di alta frequenza sono legger mente maggiori a causa della sezione ridotta in rame del conduttore e il materiale della guaina resistente alla fiamma secondo VDE 0472 T804 tipo di prova B Impiego Il cavo di bus per strutture sospese a festoni progettato per almeno 5 cicli di cur vatura con il raggio di curvatura specificato e ad un accelerazione massima di 4 m s2 Avvertenza Durante la posa e il funzionamento necessario osservare tutti i requisiti mecca nici del cavo come i raggi di curvatura le forze di tiro ecc Esempio di montaggio Carrello trascinatore Carrello cavi Protezione antipiega Morsetto terminale Cavo di tiro per lo scarico di tiro del cavo Figura 4 10 Installazione schematica del cavo PROFIBUS per strutture sospese a festoni Lunghezze
166. ale analogico Figura 3 2 Struttura di una linea di trasmissione Trasmettitore In un sistema di trasmissione ottico digitale il trasmettitore composto da una preparazione del segnale che trasforma i segnali digitali dell elettronica in una forma di impulso adatta per il convertitore elettro ottico e da un convertitore elettro ottico converitore E O che trasforma gli impulsi elettrici in segnali ottici Per SIMATIC NET PROFIBUS come convertitore E O vengono impiegati dei LED LED Light Emitting Diode LED sono adattati in modo specifico ai diversi mezzi trasmissivi Reti PROFIBUS SIMATIC NET 3 12 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Mezzi trasmissivi In SIMATIC NET PROFIBUS come mezzi trasmissivi vengono impiegati i seguenti tipi di cavi in fibra ottica FO e Cavo in fibra ottica di plastica e Cavo PCF Polymer Cladded Fiber e Cavo in fibra ottica di vetro Ulteriori dati relativi ai diversi cavi FO per SIMATIC NET PROFIBUS sono riportati nel capitolo 7 Ricevitore Il ricevitore di un sistema di trasmissione ottico digitale composto da un convertitore ottico elettrico in un fotodiodo che trasforma i segnali ottici in segnali elettrici e da una preparazione del segnale che trasforma gli impulsi elettrici forniti dal diodo in segnali compatibili con l elettronica collegata in successione Attenuazione L attenuazione di una linea di trasmissione viene determinata dai seguenti fattor
167. ale tra parti separate dell impianto possono provocare danni al sistema se C 10 apparecchi di automazione e periferia sono collegati tramite accoppiamenti senza separazione di potenziale oppure gli schermi dei cavi vengono applicati su entrambi i lati e collegati alla terra di diverse parti dell impianto Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Come evitare differenze di potenziale Differenze di potenziale devono essere ridotte installato cavi equipotenziali in modo da garantire il funzionamento dei componenti elettronici impiegati Quando e per quale motivo necessaria l equipotenzialita seguenti motivi sono a favore di un equipotenzialit Gli apparecchi con interfaccia collegata a terra possono essere danneggiati da differenze di potenziale Lo schermo del cavo PROFIBUS non deve servire come equipotenziale Que sta situazione si presenta tuttavia in caso di parti di impianto collegate tramite lo schermo del cavo ma allacciate a diversi punti di terra Per la protezione antifulmine indispensabile l equipotenzialita Regole per l equipotenzialit Per l equipotenzialita osservare i seguenti punti L azione di equipotenzialit aumenta proporzionalmente riducendo l impedenza del conduttore equipotenziale L impedenza del cavo equipotenziale supplementare installato deve essere al massimo il 10 dell impedenza dello schermo del cavo di b
168. allazione dei cavi di bus C 6 Compatibilit elettromagnetica dei cavi in fibra ottica Cavo in fibra ottica Per i collegamenti di bus tra edifici e o dispositivi esterni si raccomanda general mente l impiego di cavi in fibra ottica Grazie al principio ottico di trasmissione le fibre ottiche sono immuni a disturbi elettromagnetici Per le fibre ottiche non sono necessari provvedimenti per l equipotenzialit e la protezione da sovratensioni Avvertenza I cavi in fibra ottica sono particolarmente adatti per i collegamenti di bus in zone di impianti soggette a disturbi elettromagnetici Osservare tuttavia che i componenti di bus che funzionano su base elettrica come OLM OBT o AS con interfaccia ottica integrata non possono eventualmente essere utilizzati in queste zone senza provvedimenti supplementari di protezione contro i disturi nelle linee FO Essi devono essere protetti contro disturbi non ammessi con schermaggio messa a terra e distanza minima dalla fonte di disturbi Reti PROFIBUS SIMATIC NET C 20 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus C 7 Posa di cavi di bus C 7 1 Avvertenze per la posa di cavi di bus elettrici e ottici Informazioni generali Durante la posa necessario tenere conto che i cavi di bus possono essere sotto posti solo ad un carico meccanico limitato cavi possono essere particolarmente danneggiati o distrutti in seguito a forte trazione o pressione torsio
169. and signaling contact cable to the terminal block as illustrated in Figure 17 O S o O Terminal block B999 1 2 Bare wire approx 8 mm Core insulation approx 8 mm Cable camp FRI TE Fold back braided shield approx 8 mm NP Cable installed Figure 17 Connecting the Power Supply and Signaling Contact Cable If you have chosen a shielded cable make sure that there is a good electrical connection between the braided shield and shield clamp This is guaranteed if you fold back the braided shield over the outer jacket of the cable This provides you with a sufficiently large cable diameter to clamp the cable Screw the threaded cable inlet so that if IP65 is required the cable connection is watertight If this is required PROFIBUS cables with a round cross section and an outer diameter of 7 5 to 10 mm must be connected Tighten the threaded cable inlet with a torque of approx 2 5 to 3 Nm so that the collar of the threaded cable inlet is sealed against the casing of the PROFIBUS ILM When the cable is connected the union nut of the cable inlet must be tightened so that the cable can no longer be pulled out When tightening the nut make sure that the cable does not turn with it If the power supply and signaling contact cable is subject to changing tensile stress make sure that you provide additional strain relief The cable clamp in the devic
170. andards of the safety systems employed in the plant Certified usage Please observe the following A Warning or approved by Siemens The device may only be employed for the purposes described in the catalog and technical description and only in conjunction with external devices and components recommended The product can only be operated correctly and safely if it is transported stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Trademarks SIMATIC and SIMATIC NET are registered trademarks of Siemens AG Other designations in this manual may be registered trademarks the use of which by third parties for their own purposes may violate the rights of the owner Copyright Siemens AG 1996 to 1999 All rights reserved Transmission or duplication of this document evaluation and providing information about its contents are not permitted unless expressly authorized Non compliance with these instructions will result in claims for damages All rights reserved in particular in the event of a patent being awarded or a GM entry Siemens AG A amp D Industrial Automation Systems SIMATIC NET Postfach 4848 D 90327 N rnberg Disclaimer of liability We have checked this manual to ensure that the contents comply with the described hardware and software However deviations cannot be excluded We can therefore assume no responsibility for the total compliance
171. ange of the device maximum 60 C and the light intensity in the infrared range will be exceeded and cause functional problems It is advisable to protect the device with a sunshade making sure that it cannot subjected to direct sunlight even when the sun is extremely low Note Make sure that there is sufficient space to connect the bus and power supply cables The cables must not extend into the area of the send and receive window Copyright by Siemens 30 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Make sure that there are no infrared sources in the illumination cone in front of a PROFIBUS ILM There should also be no reflecting surfaces in any part of the illumination cone to avoid reflecting back the modules own emission Before mounting the PROFIBUS ILM connect the power supply and PROFIBUS cables if the site where the module is being installed is awkward to reach Mount the PROFIBUS ILM on a low resistance and low inductance earthed metal wall support or mounting plate Make sure that there is a reliable electrical connection between the ILM casing and the mounting plate Use toothed washers under the screw heads to break through any paint Secure the modules with machine screws for example M 4 x 30 The most suitable way of mounting the PROFIBUS ILM is to use a support that allows the module to be aligned with the partner station A suitable support would be as follows Mechanically stable Low resis
172. anleitung nicht Teil einer fr heren oder bestehenden Vereinbarung Zu sage oder eines Rechtsverh ltnisses ist oder diese ab ndern soll S mtliche Verpflichtungen von Siemens ergeben sich aus dem jeweiligen Kaufvertrag der auch die vollst ndige und allein g ltige Gew hrleistungsregel enth lt Diese vertraglichen Gew hrleistungsbestimmungen werden durch die Ausf hrungen dieser Betriebsanleitung weder erweitert noch beschr nkt WARNUNG Weitergabe sowie Vervielf ltigung dieser Unterlage Verwertung und Mitteilung ihres Inhalts nicht gestattet soweit nicht aus dr cklich zugestanden Zuwiderhandlungen verpflichten zu Schadenersatz Alle Rechte vorbehalten insbesondere f r den Fall der Patenterteilung oder GM Eintragung Copyright Siemens AG 1999 All Rights Reserved Wir weisen au erdem darauf hin da aus Gr nden der ber sichtlichkeit in dieser Betriebsanleitung nicht jede nur erdenk liche Problemstellung im Zusammenhang mit dem Einsatz dieses Systems beschrieben werden kann Sollten Sie weitere Informationen ben tigen oder sollten besondere Probleme auf treten die in der Betriebsanleitung nicht ausf hrlich genug be handelt werden k nnen Sie die erforderliche Auskunft ber die rtliche Siemens Niederlassung anfordern Das in der Anleitung beschriebene SpliTConnect Tap System ist nur f r die Verwendung mit PROFIBUS FC Process Cable bestimmt Bei anderweitiger Verwendung kann es zu Unf llen oder zur Ze
173. ari esistono per cavi per la telecomunicazione per i quali neces sario osservare le direttive locali nella Repubblica Federale Tedesca i cavi per la telecomunicazione non devono essere installati insieme ad altri cavi Categorie e distanze dei cavi Classificazione in categorie Le linee e i cavi vanno preferibilmente classificati in diverse categorie in base ai loro segnali utili ai segnali di disturbo possibili e alla loro sensibilit ai disturbi A queste categorie possibile assegnare determinate distanze di sicurezza che con sentono in condizioni normali d esercizio un funzionamento senza disturbi Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 13 Installazione dei cavi di bus Condizioni generali La classificazione dei cavi in base alle tensioni lascia presumere che le tensioni di disturbo condotte sono tanto pi ridotte quanto pi bassa la tensione utile con dotta Osservare tuttavia che p es le tensioni continue o le tensioni di alimenta zione di 50 Hz provenienti dai cavi di alimentazione non rappresentano una fonte di disturbo per cavi PROFIBUS Le tensioni problematiche di disturbo nel campo di frequenza da kHz a MHz vengono generate dagli utilizzatori allacciati al cavo Un cavo 24 V DC con il quale viene regolarmente attivato un rel rappresenta una fonte di disturbo molto pi problematica per i cavi di bus rispetto ad un cavo 230 V che fornisce l alimentazione di una lampada N
174. arsi un funzionamento errato e visualizzazioni di errore sull OLM Il LED di sistema lampeggia con luce rossa verde Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti 3 3 3 Esempio per la progettazione dei parametri di bus in STEP 7 Struttura della rete di esempio L esempio parte dal presupposto di una rete ottica ridondante con la seguente struttura e 20 OLM G12 nell anello ottico ridondante e lunghezza complessiva dell anello di 20 km e Velocit di trasmissione 1 5 Mbit s e nodi allacciati direttamente all OLM e protocollo di bus PROFIBUS DP Calcolo del tempo di slot Per la velocita di trasmissione di 1 5 Mbit s selezionata nell esempio la tabella 3 9 riporta i seguenti valori a 351 b 30 c 24 Con questi valori il tempo di slot viene calcolato nel modo seguente Tempo di slot 351 30 x 20 24 x 20 1431 Immissione dei parametri del bus Per l esempio necessario immettere i seguenti 3 parametri del bus Tempo di slot T_slot_Init 1431 Numero di tentativi Retry_Limit 3 Indirizzo stazione pi alto HSA 126 impostazione di base Con STEP 7 l immissione di questi valori viene eseguita nella finestra Parametri del bus nel profilo del bus definito dall utente Successivamente il nuovo calcolo dei parametri del bus deve essere attivato con il pulsante Nuovo calcolo Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4
175. asmissiva IEC 61158 2 5 Esso previsto per il collegamento all interno di edifici e all aperto Reti PROFIBUS SIMATIC NET 6 2 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per PROFIBUS PA 6 2 SpliTConnect Tap Settore d impiego Struttura Il SpliTConnect Tap permette di realizzare un segmento di bus PROFIBUS PA se condo IEC 61158 2 con punti di allacciamento del terminale Con lo SpliTConnect Coupler un ripartitore PROFIBUS PA pu essere realizzato collegando in cascata SpliTConnect Tap Sostituendo la vite di contatto con il SpliTConnect Terminator lo SpliTConnect Tap pu essere utilizzato come elemento di chiusura del bus Figura 6 2 PROFIBUS SpliTConnect Figura 6 3 SpliTConnect Coupler Tap Figura 6 4 SpliTConnect Terminator Figura 6 5 SpliTConnect M12 Outlet Lo SpliTConnect Tap dispone di una robusta scatola di PBT tereftalato di polibuti lene con tecnica di montaggio IP67 ed adatto per il montaggio su guide ad U oppure per il montaggio a parete Il contenitore metallico integrato garantisce uno schermaggio continuo In combinazione con il cavo di bus FastConnect per IEC 61158 2 lo SpliTConnect Tap offre un allacciamento del cavo semplice e facil mente installabile Il collegamento dei cavi di bus Fast Connect per IEC 61158 2 viene eseguito in tecnica a perforazione d isolante tramite vite di presa di contatto Un collegamento a terra supplementare dello SpliTConne
176. ati Tra i sistemi decentrati di conseguenza necessaria una maggiore co municazione Queste strutture decentrate offrono inoltre i seguenti vantaggi una messa in funzione simultanea e indipendente dei singoli componenti dell impianto la riduzione della portata dei programmi rendendoli pi accessibili l elaborazione parallela grazie a sistemi di automazione suddivisi Ne risultano riduzione dei tempi di reazione carico limitato delle singole unit di elaborazione strutture sovraordinate possono assumere funzioni supplementari di diagnostica e di compilazione di protocolli aumento della disponibilit dell impianto in quanto in caso di guasto di una sot to stazione il resto dell intero sistema pu continuare a funzionare Per una struttura dell impianto decentrata assolutamente necessario un sistema di comunicazione completo e di elevate prestazioni 1 2 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS SIMATIC NET Con SIMATIC NET la Siemens propone per l automazione di produzione e di pro cesso un sistema di comunicazione aperto e universale con reti locali livellate in base alla potenza Local Area Network LAN per l impiego nel settore industriale Il sistema di comunicazione SIMATIC NET basato su standard nazionali ed inter nazionali in conformit del modello di riferimento ISO OSI Le basi del sistema di comunicazione sono le LAN che a seconda delle condizio
177. ator 5 16 Repeater RS 485 5 4 B Differenze di potenziale Cause C 10 Baudrate 2 23 Cause C10 S E Cavi di derivazione Lunghezza 3 4 f nk Cavi in fibra ottica Cavi in fibra di pla Equipotenzialit C 10 stica 7 3 Cavo da trascinamento flessibile Fiber Optic l Cavo da trascinamento Flexible Fiber Optic Illuminazione dell armadio C 19 Installazione dei cavi Cavo di bus Lunghezza dei cavi di deriva Avvertenze C 2 zione 3 4 fuori da edifici C 17 C 19 Cavo Fiber Optic standard 7 14 Installazione dei cavi di bus Awertenze C 2 Cavo in fibra ottica 7 2 Cavo in fibra ottica di PCF 7 10 Cavo in fibra ottica di vetro 7 13 Cavo in fibra ottica di vetro Dati tecnici 7 14 Cavo marino duplex in fibra ottica SIENOPYR Manuale Sistem di adiamaziano 37300 M7 300 ET 200M Unit periferiche Ex I 3 7 15 7 22 Cavo per installazione all interno di edifici IN hi di ug DOOR Fiber Optic 7 18 442 Montaggio del cavo di bus sul connettore di bus 6ES7 972 0B 10 4 38 sul connettore di bus 6ES7 972 0BA30 Cavo per l installazione all interno di edifici IN DOOR Fiber Optic 7 14 Cavo standard Fiber Optic 7 17 Connettore di bus 4 33 Assegnazione dei pin 4 36 collegamento all unita 4 46 p Dati tecnici 4 35 Disegno in scala F 2 Possibilit di configurazione con il repeater RS Impostazione della resistenza terminale 485 5 6 PROFIBUS Terminator Settore di impiego 4
178. aud con i parametri impostati nel modo seguente 8 N 1 ANSI o selezionare tramite ISDN x 75 64 kBit Riferimento di linee speciali accessori e attrezzi Linee speciali e lunghezze speciali di tutti i cavi di bus SIMATIC NET nonch ac cessori attrezzi e misuratori sono disponibili su richiesta presso A amp D SE V22 WKF F rth Hr Hertlein Tel 0911 750 4465 Fax 0911 750 9991 e mail juergen hertlein fthw siemens de Ulteriore supporto J 2 Per domande relative ai prodotti SIMATIC NET rivolgersi al consultente Siemens presso le filiali e societa regionali responsabili Gli indirizzi sono riportati e nel nostro catalogo IK PI in Internet E Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Glossario Anello token Tutti i master collegati fisicamente con un bus ricevono il token e lo inoltrano al master successivo il master si trrova nell anello token Attenuazione della linea FO L attenuazione della linea composta da tutti gli effetti di attenuazione che si tro vano sul percorso di una linea FO Essa viene generalmente causata dalle fibre stesse e dai punti di sdoppiamento e di accoppiamento L attenuazione della li nea deve essere pi bassa rispetto al budget di potenza disponibile tra il trasmet titore e il ricevitore Baudrate gt Velocit di trasmissione Budget di potenza FO disponibile tra un trasmettitore e un ricevitore di una linea FO Specifica la dif
179. avi in fibra ottiche di plastica sono facilmente confezionabili Esistono le seguenti versioni di connettori e Connettore simplex per l allacciamento di OBT e interfacce ottiche integrate e Adattatori per connettori simplex per interfacce ottiche integrate e Connettore BFOC per OLM P 7 4 2 Connettore simplex e adattatori per apparecchi con interfacce ottiche integrate Definizione connettori simplex servono per l allacciamento del cavo in fibra ottica all interfac cia ottica integrata dell apparecchio PROFIBUS Per alcune unit della Siemens p es IM 153 2 FO IM 467 FO sull unit vengono innestati rispettivamente due connettori simplex uno per la trasmissione e uno per la ricezione tramite un adat tatore speciale Presupposti 7 26 L apparecchio PROFIBUS deve disporre di un interfaccia ottica come p es ET 200S IM151 FO o IM 467 FO per S7 400 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Struttura Per l allacciamento del cavo in fibra ottica sono necessari due connettori simplex trasmettitore e ricevitore ed eventualmente un adattatore con le seguenti pro priet e Clase di protezione IP 20 e Velocit di trasmissione da 9 6 kbaud a 12 Mbaud Adattatore Ricevitore Trasmettitore gt Bi QI Connettore Cavo in fibra simplex ottica Figura 7 9 Connettor
180. ay Responder Messa a terra Messa a terra significa che una parte elettrica con conduzione elettrica deve es sere collegata al terreno con buona conduzione terminale un impianto di messa a terra Metodo master slava Metodo di accesso nel quale solo un nodo il master e tutti gli altri nodi sono slave min_Tspr Min_Tspr un parametro di bus e rappresenta il tempo minimo per elabora zione del protocollo del nodo che risponde Station Delay Responder Nodo Apparecchio che pu trasmettere e ricevere dati come master o slave su PROFI BUS Reti PROFIBUS SIMATIC NET Glossar 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Glossario Potenziale di riferimento Potenziale a partire dal quale vengono calcolate e o misurate le tensioni dei cir cuiti elettrici PROFIBUS PROcess Fleld BUS norma europea per processo e bus da campo definita nella norma PROFIBUS EN 50 170 volume 2 PROFIBUS Essa presenta propriet funzionali elettriche e meccaniche per un sistema di bus da campo con trasmissione seriale dei bit PROFIBUS un sistema di bus che collega in rete i sistemi di automazione e le apparecchiature da campo compatibili con PROFIBUS nel livello di cella e di campo PROFIBUS disponibile con protocolli DP periferia decentrata FMS Fieldbus Message Specification o PA automazione del processo PROFIBUS DP Sistema di bus PROFIBUS con il protocollo DP DP significa periferia decentrata Il compi
181. azione e Facilmente confezionabile con l attrezzo spelafili sopraindicato FC Stripping Tool e Possibilit di verificare l assegnazione dei pin dal connettore PROFIBUS FC chiuso grazie alla copertura trasparete dei morsetti di perforazione e codifica colore per l assegnazione dei conduttori 4 2 2 Settore di impiego e dati tecnici del connettore di bus FastConnect Settore d impiego connettori di bus sono necessari per allacciare cavi PROFIBUS alle interfacce Sub D a 9 poli Nel sistema FastConnect esistono diversi connettori di bus con classe di protezione IP 20 La tabella 4 3 elenca i tipi di impiego Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 25 Componenti passivi per reti RS 485 Tabella 4 3 Struttura e settore di impiego dei connettori di bus FastConnect in IP 20 Numero di ordinazione Aspetto 6ES7 972 0BA50 0XA0 6GK1 500 0FC00 6ES7 972 0BB50 0XA0 Raccomandato per IM 308 B IM 308 C S5 95U Q a partire dalla ver sione 6 S7 200 S7 300 S7 400 M7 300 M7 400 07 626 DP da S5 115U a 155U oo 0000 CP 5412 CP 5613 CP 5614 CP 5411 CP 5511 CP 5611 CP 5431 FMS DP CP 342 5 CP 342 5 CP 443 5 OOOO ET 200B ET 200L ET 200M ET 200S ET 200U oo000 0000 PG 720 720C PG 730 PG 740 PG 750 PG 760 Repeater RS 485 OP OLM ooo00000 4 26 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Ed
182. azione dell energia Automazione industriale vale a dire PROFIBUS disponibile e si intende includere nell automazione i com ponenti della tecnica elettrica di installazione di una linea di montaggio di un im pianto o di un capannone di produzione Per questo impiego indispensabile l equipaggiamento degli edifici industriali Gli impiegi possono essere e comando dell illuminazione e comando tapparelle e rilevamento di temperatura intensit del vento oppure posizione del sole e comando di portoni e e controllo degli accessi L instabus EIB specializzato per i compiti indicati e offre una vasta scelta di com ponenti ed estensione della rete max 1000 m per ogni linea Su una rete sono possibili fino a 11 520 apparecchiinstabus EIB max 15 settori con rispettivamente max 12 linee con rispettivamente fino a 64 nodi Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 35 Topologie delle reti SIMATIC NET PROFIBUS S7 300 ET 200M ET 200S PROFIBUS Step 7 o COM PROFIBUS instabus EIB Interfaccia EIB Figura 2 25 Esempio di una configurazione del sistema con DP EIB Link Reti PROFIBUS SIMATIC NET 2 36 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Tipo di funzionamento Gli oggetti dei dati dell instabus EIB vengono rappresentati nell area I O PROFI BUS L
183. bi dell impianto marchi CE e Fissare lo schermo del cavo di bus al contenitore del connettore e In caso di funzionamento stazionario si consiglia di togliere l isolamento del cavo schermato senza interruzioni e di appoggiarlo sulla guida di schermaggio del conduttore di protezione Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Avvertenza In caso di differenze di potenziale tra i punti di collegamento a terra sullo schermo allacciato su entrambi i lati pu passare corrente di compensazione con un voltag gio maggiore non ammesso Per eliminare questo problema non togliere mai lo schermo del cavo di bus e Installare parallelamente al cavo di bus un cavo equipotenziale supplementare che assuma la corrente dello schermo avvertenze relative all equipotenzialita sono riportate nel capitolo C 4 4 e Realizzare il collegamento del bus con cavi in fibra ottica solu zione pi sicura Misure per il trattamento dello schermo Per il trattamento dello schermo osservare i seguenti punti e Fissare la maglia di schermatura alle fascette serracavi in metallo e Le fascette devono avvolgere lo schermo su un ampia superficie e presentare un buon contatto vedere figura C 3 e Eseguire il contatto dei cavi SIMATIC NET PROFIBUS solo sullo schermo a maglia di rame e non sullo schermo a lamina di alluminio Per aumentare la re sistenza allo strappo lo schermo a lamina appl
184. bove check the optical receiving level of the other OLM in the disturbed optical fiber segment at the appropriate port The levels at both OLMs of the disturbed optical fiber segments are in the range Optical system reserves reduced or Normal mode one of the two OLMSs in the disturbed optical fiber segments is defective First replace one of the OLMs in the disturbed optical fiber segment If the fault still persists replace the other OLM instead 28 Version 1 1 8 00 6 Configuration 6 1 Configuration of optical line and star topologies 6 Configuration During configuration the PROFIBUS network parameter Slot time must be adapted to the network coverage network topology and the data rate due to frame delays caused by lines and network components as well as by monitoring mechanisms in the network components 6 1 Configuration of optical line and star topologies The PROFIBUS network is configured e g with SIMATIC STEP 7 V5 or COM PROFIBUS V5 The number of OLMs Number om and overall line lengths can be entered in an input mask The configuration tools control whether the slot time in the selected communications profile can be retained If this time is exceeded as a result of additional OLM and optical fiber line runtimes an error message is issued and the parameters are adapted accordingly 6 2 Configuration of redundant optical rings The following configuration conditions must be fulfilled in the redundant optical r
185. bus possono essere impiegati per velo cit di trasmissione fino a 12 MBit s Tabella 2 1 Componenti per velocit di trasmissione fino a 12 Mbit s Numero di ordinazione Connettore di bus per PROFIBUS con uscita cavo assiale 6GK1 500 0EA02 PROFIBUS FastConnect connettore di bus RS 485 Plug 180 con uscita cavo a 180 6GK1500 0FC00 Connettore di bus RS 485 con uscita cavo verticale senza interfaccia PG con interfaccia PG 6ES7 972 0BA11 0XA0 6ES7 972 0BB11 0XA0 PROFIBUS FastConnect connettore di bus RS 485 con uscita cavo a 90 con tecnica a perforazione d isolante velocit massima di trasmissione 12 Mbit s senza interfaccia PG con interfaccia PG 6ES7 972 0BA50 0XA0 6ES7 972 0BB50 0XA0 Connettore di bus RS 485 con uscita cavo a 35 senza interfaccia PG con interfaccia PG 6ES7 972 0BA40 0XA0 6ES7 972 0BB40 0XA0 SIMATIC NET cavo di connessione 830 1T confezionato previsto con resistenze terminali come collegamento tra in terfaccia elettrica di un OLM o OBT e interfaccia PROFIBUS di un nodo PROFIBUS 1 5m 3m 6XV1830 1CH15 6XV1830 1CH30 SIMATIC NET cavo di connessione 830 2 per PROFIBUS cavo preconfezionato con due connettori SUB D a 9 poli re sistenze terminali attivabili 3m 5m 10m 6XV1830 2AH30 6XV1830 2AH50 6XV1830 2AN10 SIMATIC S5 S7 cavo di connessione per PROFIBUS per allacciamento PG fino a 12 Mbit s confezionato con 2 connettori Sub D lunghezza
186. cciamento a mezzi trasmissivi FO di diverso tipo 1 o 2 interfacce ottiche tecnica di allacciamento BFOC e Interfaccia RS485 segmentabile e con separazione di potenziale connettore femmina Sub D e Funzionamento multimaster illimitato Funzione ampliata di segmentazione per limitazione dei guasti su segmenti FO e RS 485 e Localizzazione rapida dei guasti Indicazione dello stato del modulo con contatto di segnalazione a potenziale libero Controllo della qualit della linea FO uscita di misura per ricevitori ottici per la compilazione di protocolli e la determinazione della qualit del segnale FO con voltmetro e Elevata profondit di collegamento in cascata Linea e anello ridondante fino a 122 OLM limitati solo dai tempi di controllo e Alimentazione 24 V DC con possibilit di alimentazione ridondante Avvertenza Le interfacce ottiche degli OLM sono ottimizzate per elevati raggi di azione L ac coppiamento diretto delle interfacce ottiche di un OLM con un OBT o interfacce ottiche integrate non ammesso a causa dei dati tecnici differenti Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti ottiche Dati per l ordinazione N di ordinazione PROFIBUS OLM P11 6GK1 502 2CA00 Optical Link Module con 1 interfaccia RS485 e 1 interfaccia per fibra ottica di plastica con con tatto di segnalazione e uscita di misura PROFIBUS OLM P12 6GK1 502 3CA00 Optica
187. ce Sistemi utilizzabili possibile allacciare i seguenti sistemi sistemi di automazione SIMATIC S5 S7 M7 C7 sistema di periferia decentrata ET 200 SIMATIC PG PC apparecchiature e sistemi di servizio e supervisione SIMATIC SICOMP IPC controlli numerici CNC SINUMERIK senori SIMODRIVE SIMOVERT Master Drives sistema di regolazione digitale SIMADYN D SIMOREG Micromaster Midimaster invertitori di potenza attuatori SIPOS regolatori industriali di processo SIPART sistemi di identificazione MOBY apparecchi di manovra a bassa tensione SIMOCODE interruttori automatici centralina di automazione compatta SICLIMAT COMPAS sistema di controllo processo TELEPERM M apparecchi di altri fornitori con allacciamento per PROFIBUS Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 1 5 RETI PROFIBUS Mezzi trasmissivi Le reti PROFIBUS possono essere realizzate anche sulla base di e cavi schermati a due conduttori intrecciati impedenza caratteristica 150 Q e cavi schermati a due conduttori intrecciati a sicurezza intrinseca con PROFI BUS PA e cavi in fibra ottica e senza fili tecnica a raggi infrarossi Le diverse reti di comunicazione possono essere sia indipendenti una dall altra sia a seconda della necessit combinate tra di loro Reti PROFIBUS SIMATIC NET 1 6 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS 1 2 1 Norme e standard SIMATIC NET PROFIBUS basata sui seguenti
188. ciamento del cavo Altri cavi che si trovano nello stesso festone non devono comportare un supera mento dei raggi minimi di curvatura del cavo di bus Figura 4 11 Esempio di impiego di un cavo PROFIBUS per strutture sospese a festoni Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 21 Componenti passivi per reti RS 485 4 1 9 Cavo marino SIENOPYR FR Guaina interna di polimero esente Conduttore interno da alogeni a trefoli in rame Conduttore di supporto Schermo a maglia in rame P Foglio di schermatura in alluminio Guaina esterna di polimero esente Protezione di isolamento in da alogeni PE cellulato Figura 4 12 Principio di struttura del cavo marino SIENOPYR FR Cavo marino SIENOPYR FR 6XV1830 0MH10 Il cavo marino SIENOPYR FR soddisfa i requisiti di EN 50170 tipo di cavo A Il conduttore interno composto da trefoli in rame a 7 conduttori ca AWG22 La guaina esterna di polimero esente da alogeni con struttura a reticolo caratte rizzata dalla sua eccellente resistenza a lubrificanti e carburanti liquidi idraulici detergenti a freddo e acqua deionizzata La guaina esterna del cavo marino SIENOPYR FR pu essere tolta separatamente in modo che la guaina interna possa essere inserita in tutti i connettori PROFIBUS con apertura di inserimento cavo di 8 mm Il cavo non adatto per l impiego del FastConnect FC Stripping Tool Propriet Il cavo marino SIENOPYR FR presenta le
189. complessiva viene considerata come riserva di si stena di una linea ottica Questa riserva di sistema non deve trovarsi al di sotto di 3 dB per linee di fibre ottiche multimode e al di sotto di 2 dB per linee di fibre otti che singlemode Reflettometro OTDR Se la misurazione di attenuazione descritta precedentemente d come risultato un eccessiva attenuazione complessiva della linea FO necessario determinare la causa e la posizione del guasto Per poter eseguire questa operazione vengono impiegati i cosiddetti misuratori OTDR OTDR Optical Time Domain Reflectome ter Figura A 3 Optical Time Domain Reflectometer OTDR misuratori OTDR sono disponibili per lunghezze d onda 850 nm e 1300 nm In questo modo il reflettometro pu essere impiegato sia per FO multimode sia per FO singlemode Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 A 9 TECNICA DI MISURA PROFIBUS Tipo di funzionamento di un OTDR A 10 Il tipo di funzionamento pu essere paragonato a quello di un apparecchio radard L OTDR trasmette impulsi di luce laser nel cavo FO aperto sull estremit da con trollare Questi impulsi di luce vengono riflessi in modo pi o meno intenso da tutti i punti di disturbo lungo il cavo Un ricevitore di misura analizza gli impulsi riflessi in base all intensit e al tempo di propagazione Trasmettitore luce laser Test FO 1 Trasmissione impulsi di luce 2 Analisi delle rifle
190. con interfaccia PG N di ordinazione 6ES7 972 0BB40 0XA0 Bus terminal BT12M N di ordinazione 6GK1500 0AA10 Repeater RS 485 allacciamento dei segmenti di bus N di ordinazione 6ES7 972 0AA01 0XA0 Terminator PROFIBUS elemento di terminazione attivo RS485 N di ordinazione 6ES7 972 0DA01 0AA0 Cavo di derivazione SIMATIC S5 S7 per allacciamento PG di 12 MBaud a PROFIBUS DP N di ordinazione 6ES7 901 4BD00 0XA0 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 5 Progettazione di reti Regole Con una velocit di trasmissione di 1 5 Mbit s per il numero ammesso di nodi e la loro ripartizione assegnazione su un segmento SIMATIC NET PROFIBUS valgono le seguenti regole 1 Il numero massimo ammesso di nodi su un segmento 32 2 La somma dei fattori capacitivi di tutti gli elementi di allacciamento su un segmento deve essere lt 25 3 Per le distanze tra gli elementi di allacciamento adiacenti valgono le seguenti regole la distanza in questo caso la lunghezza del cavo di bus 3 1 Se la distanza degli elementi di allacciamento adiacenti maggiore di 10 m non necessario calcolare i fattori capacitivi degli elementi di allacciamento 3 2 Se la distanza degli elementi di allacciamento maggiore della somma di entrambi i fattori capacitivi degli elementi in metri l assegnazione semplice e non necessario osservare condizioni generali supplementari Il fattore capacitivo de
191. critto nel capitolo 4 Cavi SIMATIC NET PRO FIBUS Raggi di curvatura C 22 Per evitare danneggiamenti nei cavi di bus i raggi di curvatura minimi ammessi dei cavi non devono essere mai superati Fare attenzione che e durante l inserimento sotto tiro i raggi di curvatura devono essere molto supe riori rispetto ad un installazione a riposo e i raggi di curvatura per cavi appiattiti valgono solo per curvature sul lato piatto Le curvature sul lato pi alto necessitano di raggi notevolmente superiori raggi di curvatura ammessi per i cavi di bus sono riportati nei dati tecnici dei cavi di bus nel capitolo 4 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Come evitare la formazione di piegature ad ansa Durante la posa arrotolare il cavo di bus in modo tangenziale dal tamburo del cavo oppure utilizzare il relativo piattello girevole Cos facendo possibile evitare la formazione di piegature ad ansa con conseguenti punti di piegatura e torsioni del cavo Installazione a posteriori Durante la posa dei cavi di bus necessario fare attenzione che da installati i cavi non vengano caricati in modo non ammesso Questo p es possibile se i cavi sono stati installati insieme ad altre linee e cavi sulla stessa passerella o sullo stesso canale per cavi se ammesso dalla sicurezza elettrica e devono essere aggiunti cavi nuovi in caso di riparazioni ampliamenti Se
192. ct Tap possibile tramite la vite di presa di contatto Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 6 3 Componenti passivi per PROFIBUS PA Tipo di funzionamento 6 4 Lo PROFIBUS SpliTConnect Tap permette di realizzare un segmento di bus PRO FIBUS PA secndo IEC 61158 2 5 e l allacciamento di terminali di dati Il sistema di allacciamento FastConnect FastConnect Stripping Tool FastConnect cavo di bus per IEC 61158 2 permette una confezione semplice L allacciamento di termi nali di dati pu essere eseguito direttamente con cavo di bus Fast Connect per IEC 61158 2 oppure con SpliTConnect M12 Outlet Tabella 6 1 Dati per l ordinazione Dati per l ordinazione SpliTConnect Tap Per la realizzazione di segmenti PROFIBUS PA e l allacciamento di apparecchiature da campo PA tecnica a perforazione d isolante IP 67 Fornitura 10 pezzi 1 confezione N di ordinazione 6GK1 905 0AA00 SpliTConnect M12 Outlet Elemento di inserimento per l allacciamento diretto di apparecchiature da campo PROFI BUS PA a SpliTConnect Tap tramite allaccia mento M12 Fornitura 5 pezzi 1 confezione 6GK1 905 0AB00 SpliTConnect Coupler Elemento di collegamento per il collegamento in cascata di SpliTConnect Tap per la realizza zione di punti a stella Fornitura 10 pezzi 1 confezione 6GK1 905 0AC00 SpliTConnect Terminator Ex Per l allacciamento di segmenti di bus PROFI BUS PA p
193. d TX LED lit orange acknowledg ment pulse RX LED not lit 41 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 LED Display POWER LED TX LED RX LED POWER LED TX LED RX LED LOW LED POWER LED TX LED RX LED POWER LED TX LED RX LED LOW LED POWER LED lit green lit orange lit yellow lit green lit orange lit yellow lit red lit green lit yellow not lit lit green lit yellow lit yellow lit red lit green TX and RX LEDs not lit ERROR LED POWER LED RX LED ERROR LED Table 1 lit red lit green lit yellow lit red Possible Causes No acknowledgment pulse received since partner station not configured with acknowledgment pulse On point to multipoint links on the PROFIBUS ILM of the master subnet if acknowledgment bit configured see Section 6 4 No acknowledgment pulse received since partner station is not configured with acknowledgment pulse or receive level for acknowledgment pulse and response frame too low On a point to multipoint link on the PROFIBUS ILM on a slave subnet if configured with acknow ledgment bit see Section 6 4 Partner station not responding because not atta ched infrared link interrupted incorrectly configu red PROFIBUS address of the slave incorrect data rate of the partner PROFIBUS ILM set incor rectly etc Risk of problems on bus since infrared link has too much attenuation obstacles in area of tra
194. dell accoppiatore DP PA nel sistema Settori di impiego dell accoppiatore DP PA L accoppiatore DP PA disponibile in due versioni e Accoppiatore DP PA Ex i possono essere allacciati tutte le apparecchiature da campo certificate per PROFIBUS PA e che si trovano nell area soggetta a pericoli di esplosione e Accoppiatore DP PA possono essere allacciati tutte le apparecchiature da campo certificate per PROFIBUS PA e che si trovano fuori dall area soggetta a pericoli di esplosione L accoppiatore DP PA rappresenta un mezzo d esercizio appartenente secondo EN 50014 e EN 50020 e deve quindi essere montato al di fuori dell area soggetta a pericoli d esplosione Reti PROFIBUS SIMATIC NET 2 22 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Propriet dell accoppiatore DP PA generali L accoppiatore DP PA presenta le seguenti caratteristiche e Separazione di potenziale tra PROFIBUS DP e PROFIBUS PA e Conversione del mezzo fisico di trasmissione tra RS 485 e IEC 61158 2 e Diagnostica tramite LED e Velocit di trasmissione su PROFIBUS DP 45 45 kbit s e Velocit di trasmissione su PROFIBUS PA 31 25 kbit s e Alimentatore integrato Propriet dell accoppiatore DP PA Ex i L accoppiatore DP PA Ex i 6ES7 157 0AD00 0XA0 presenta inoltre le seguenti caratteristiche e Tipo di protezione da scintille EEx ia Il C e Sicurezza intrinseca e alimentatore a sicurezza intrins
195. dentificative Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 E 1 Installazione di componenti di rete in un armadio Entit della protezione E 2 Le sigle dei diversi gradi di protezione sono riportati nella tabella E 1 Per informa zioni dettagliate e le condizioni esatte di collaudo dei singoli gradi di protezione consultare le norme sopraindicate Tabella E 1 Entit di protezione per i gradi di protezione sigla Cifra iden Protezione da contatto e da Protezione da acqua tificativa corpi estranei 0 nessuna protezione nessuna protezione 1 contro corpi estranei con un dia Gocce con caduta verticale metro di gt 50 mm 2 contro corpi estranei con un dia Con gocce con caduta obliqua di metro di gt 12 mm 15 3 contro corpi estranei con un dia Spruzzi d acqua obliqui fino a metro di gt 2 5 mm 60 5 contro corpi estranei con un dia Spruzzi d acqua in qualsiasi dire metro di gt 1mm zione 6 Depositi di polvere Spruzzi d acqua o getti d acqua provenienti da un ugello 7 Infiltrazioni di polvere ermetico Forti getti d acqua alla polvere 8 Immersione temporanea con pressione e durata definita 9 Immersione permanente con pressione e durata definita Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione di componenti di rete in un armadio E 2 Componenti SIMATIC NET Aperture di ventilazione A
196. dentified by an arrow pointing out of a circle Page 5 SIMATIC NET PROFIBUS PCF Fiber Optic Standard Cable Ordering Data SIMATIC NET PROFIBUS PCF Fiber Optic standard cable I VY2K 200 230 10A17 8B20 PCF FO cable with 2 cords PVC outer jacket for spanning distances up to 400 m assembled with 2 x 2 BFOC connectors outer jacket stripped over 20 cm at both ends with pulling loop fitted at one end for connecting OLM P Standard lengths 75m 6XV1821 1BN75 100m 6XV1821 1BT10 150m 6XV1821 1BT15 200m 6XV1821 1BT20 250m 6XV1821 1BT25 300m 6XV1821 1BT30 400m _ 6XV1821 1BT40 other lengths available on request SIMATIC NET PROFIBUS PCF Fiber Optic cable I VY2K 200 230 10A17 8B20 PCF FO cable with 2 cords PVC outer jacket for spanning distances up to 300 m preassembled with 2 x 2 simplex connectors outer jacket stripped over 30 cm with pulling loop fitted at one end for connecting devices with integrated optical interfaces and OBT Standard lengths 50m 6XV1821 1CN50 75m 6XV1821 1CN75 100m 6XV1821 1CT10 150m 6XV1821 1CT15 200m 6XV1821 1CT20 250m 6XV1821 1CT25 300m 6XV1821 1CT30 other lengths available on request Note You can order other lengths and additional components for the SIMATIC NET cabling range from your local representative For technical advice contact J Hertlein Siemens AG A amp D SE V22 Tel 0911 750 4465 Fax 0911 750 9991 E mail juergen hertlein fthw siemens de Page 6
197. di bus standard nel cavo da trascinamento i conduttori sono costi tuiti da cavetti in rame La particolare combinazione di schermo a maglia a foglio di tessuti e della guaina in poliuretano permette di ottenere un elevata flessibilit e di mantenere le propriet elettiche In caso di allacciamento con morsetti a vite i conduttori a trefoli devono essere avvitati solo con l aiuto di capicorda 0 25 mm secondo DIN 46228 Il connettore di bus 6ES7 972 OBA30 0XA0 non pu essere allacciato Per facilitare un installazione senza torsioni sulla guaina esterna stampata una linea in direzione longitudinale La struttura del cavo permette l impiego del FastConnect FC Stripping Tool perla preparazione rapida della guaina esterna vedere capitolo 4 2 3 Reti PROFIBUS SIMATIC NET 4 14 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Propriet Rispetto al cavo di bus standard il cavo da trascinamento presenta le seguenti propriet e un ottima resistenza allo sfregamento e resistenza a grassi e oli minerali e un ottima resistenza a radiazioni UV e piccoli raggi di curvatura per la posa e il funzionamento e la resistenza del conduttore e l attenuazione di alta frequenza sono maggiori a causa della sezione ridotta in rame e il materiale della guaina esterna resistente alla fiamma Impiego Il cavo da trascinamento progettato per almeno 4 milioni di cicli di curvatura con il raggio
198. di curvatura specificato e ad un accelerazione massima di 4 m s e di con seguenza particolarmente adatto per l installazione in catene portacavi Avvertenza Durante la posa e il funzionamento necessario osservare tutti i requisiti mecca nici del cavo come i raggi di curvatura le forze di tiro ecc Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 15 Componenti passivi per reti RS 485 Figura 4 8 Esempio di impiego del cavo da trascinamento PROFIBUS in una catena portacavi Lunghezze di segmento A causa dell elevata resistenza del conduttore a basse velocit di trasmissione sono ammesse solo lunghezze di segmento leggermente ridotte vedere tabella 3 1 Per velocit di trasmissione gt 500 kbit s il cavo da trascinamento presenta gli stessi valori del cavo di bus standard Reti PROFIBUS SIMATIC NET 4 16 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Avvertenza In caso di allacciamento con morsetti a vite i conduttori a trefoli devono essere avvitati solo con l aiuto di capicorda 0 25 mm secondo DIN 46228 Utilizzare solo copicorda di materiale con propriet di contatto a stabilit permanente p es rame con superficie stagnata non alluminio Il connettore di bus 6ES7 972 0BA30 0XA0 non pu essere allacciato ai condut tori a trefoli Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485
199. di ricezione dei due canali ottici possono essere determinati con un voltmetro convenzionale tramite prese di misura Il volmetro pu essere collegato o scollegato durante il funzionamento con due connettori di prova da laboratorio di 2 mm senza effetti di retroazione vedere figura A 6 Figura A 6 Controllo della qualait del segnale per OLM V3 tramite voltmetro possibile e documentare la potenza ottica in arrivo p es per misurazioni successive invecchiamento danneggiamento e eseguire un controllo della qualit valore limite L assegnazione della tensione di uscita misurata in funzione della qualit del se gnale viene eseguita sotto forma di una curva vedere figura A 7 Reti PROFIBUS SIMATIC NET A 12 6GK1970 5CA20 0AA4 Edizione 2 05 2000 TECNICA DI MISURA PROFIBUS Signal quallity good Normal operation critical poor 800 900 Output voltage mV Figura A 7 Assegnazione della tensione in funzione della qualita del segnale per OLM G12 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 A 13 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Protezione contro fulmini e sovratensioni per cavi di bus che si estendono in pi edifici Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 B B 1 Protezione contro fulmini e sovratensioni per cavi di bus che si estendono in pi edifici B 1 Per quale motivo necessario proteggere il sistema di
200. do che lo schermo a maglia appoggi direttamente sulla fascetta per cavi 7 Avvitare le estremit dei contuttori con i relativi morsetti per i conduttori a trefoli p es cavi da trascinamento necessario utilizzare capicorda con 0 25 mm secondo DIN 46228 8 Se il bus terminal si trova all inizio o alla fine di un segmento necessario attivare la terminazione del cavo integrata posizione dell interruttore rotante Terminator on Reti PROFIBUS SIMATIC NET 4 56 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Avvertenza Le fascette di schermatura servono solo per il contatto degli schermi e non sono adatte per lo scarico di tiro cavi di bus devono di conseguenza essere raccolti possibilmente in prossimit del bus terminal per lo scarico di tiro meccanico Avvertenza Per l alimentazione della terminazione integrata attivata i bus terminal installati all estremit di un segmento necessitano dei 5 V di tensione di alimentazione dall interfaccia del terminale di dati Per questo motivo il connettore Sub D deve sempre essere innestato e avvitato II terminale di dati allacciato non deve essere disattivato Avvertenza conduttori uguali verde e rosso devono essere collegati nello stesso modo allo stesso allacciamento A e B in tutti i bus terminal e generalmente in tutti gli allac ciamento di bus di un segmento Per una rete PROFIBUS consigliato Allacciamento
201. e itself is only intended for low resistance discharge of spurious voltages on the shield The threaded cable inlet is used only for sealing the cable entry and to prevent the cable being pulled out accidentally Neither of these however is intended as strain relief against continuous tensile stress on the cables Copyright by Siemens 38 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Figure 18 shows the functional wiring of the power supply and signaling contact cable The pair of cores connected to and supplies the power for the PROFIBUS ILM This pair must always be wired up Electronics of the ILM H FP pee Signaling contact normally closed contact Terminal block for gt power supply and signaling contact _ S1 S2 Power supply Power supply 20 to 30 V max 30 V max 300 mA max 1A NEC Class 2 NEC Class 2 Figure 18 Wiring of the Power Supply and Signaling Contact The pair of cores connected to S1 and S2 is used to wire the signaling contact and is only necessary if you intend to use the signaling contact The signaling contact is closed in normal operation and opens if the following problems occur gt The device has no power supply gt Acknowledgment pulse was not detected acknowledgment pulse mechanism activated and configured to trigger the signaling contact gt No changing reception activity on the optical receiver if this was configur
202. e master PROFIBUS ILM the poorer monitoring of the link because the acknowledgment pulse mechanism cannot be used see Section 5 6 2 Copyright by Siemens 16 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM PROFIBUS master network segment Ea Infrared transmission link 1 0 5 to 15m PROFIBUS slave network segment 1 Infrared transmission link 2 0 5 to 15m PROFIBUS slave network segment 2 Infrared transmission link 3 0 5 to 15m slave network segment 3 Figure 5 Point to Mulitpoint Link with n 1 PROFIBUS ILMs One Master Subnet 3 Subnets with Slaves 17 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 5 3 Signal Regeneration The PROFIBUS ILM regenerates the signal shape and amplitude of the received signals This makes it possible to cascade unconnected network segments using infrared transmission links Since the PROFIBUS ILM however has a delay time for processing and passing on the signal the delay on the PROFIBUS ILM must be taken into account If fast response times are required in a DP system cascading must be restricted depending on the remaining network length and other active components in the network repeaters OLMs 5 4 Monitoring the Received Optical Level The PROFIBUS ILM monitors the received level when receiving data
203. e per collegare un nodo singolo PROFIBUS con interfaccia RS 485 al cavo di bus PROFIBUS bus terminal sono disponibili nelle seguenti versioni Tabella 4 9 Versioni alternative del bus terminal N di ordinazione Bus terminal RS 485 Bus terminal 12 M con cavo di derivazione di 1 5 m 6GK1 500 0AA10 con cavo di derivazione di 1 5 m e interfaccia PG integrata 6GK1 500 0DA00 con cavo di derivazione di3m 6GK1 500 0AB00 Velocit di trasmissione da 9 5 kbit s a 1 5 Mbit s da 9 5 kbit s a 12 Mbit s Alimentazione 5V 10 mA dall interfaccia del nodo 5V 90 mA dall interfaccia del nodo Combinazione di resistenze terminali integrata attivabile integrata attivabile con fun zione di scollegamento Classe di protezione conteni tore IP 20 IP 20 4 48 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 7 2 Struttura e tipo di funzionamento del bus terminal RS 485 Figura 4 27 Bus terminal RS 485 Bus terminal RS 485 Il bus terminal RS 485 serve per il collegamento di terminali di dati con interfaccia RS 485 al cavo di bus Esso comprende e 6 morsetti in fila per conduttori con sezione di lt 1 5 mm per l allacciamento del cavo di bus in arrivo e in parteza e se necessario di terra PE Protective Earth e fascette a vite per il contatto di schermatura e un interruttore
204. e simplex con adattatore speciale montato Numero di ordinazione Connettore simplex e adattatore possono essere ordinati nel modo seguente Tabelle 7 6 Numero di ordinazione Connettore simplex e adattatore Accessori Numero di ordinazione SIMATIC NET PROFIBUS Plastic Fiber Optic connet 6GK1901 0FB00 0AA0 tori simplex set di finitura 100 connettori simplex e 5 set di finitura per la confe zione di cavi SIMATIC NET PROFIBUS Plastic Fiber Optic Adattatore 6ES7195 1BE00 0XA0 Confezione da 50 pezzi per il montaggio di connettori simplex di plastica in combinazione con IM 467 FO CP 342 5 FO e IM 153 2 FO Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 27 Componenti passivi per reti ottiche Lunghezze dei cavi Utilizzando cavi FO la lunghezza della linea di trasmissione non dipende dalla 7 28 velocit di trasmissione Ogno nodo di bus sulla rete ottica PROFIBUS dispone della funzionalit di repea ter in modo che le seguenti specificazioni si riferiscano alla distanza tra due nodi PROFIBUS adiacenti della topologia lineare La lunghezza massima del cavo tra due nodi PROFIBUS dipende dal tipo di cavi in fibra ottica impiegato Tabelle 7 7 logia lineare Lunghezze di cavo ammesso nella rete con interfacce ottiche integrate topo Cavo in fibra ottica Lunghezze massime del Calcolato su 1 rete cavo standard SIMATIC NET cavo 32 nodi in m PROFI
205. e sure that the crimping sleeve is fixed to the cord and the crimping sleeve fully in the tool Note The tool can only be opened again after the required pressure has been reached Push the anti kink boot onto the Cut off excessive fiber with scissors Repeat the same procedure for the connector body as far as the end stop leaving approximately 0 5 mm in length second cord Caution Do not insert the connector into a device socket otherwise the excess fiber length extending out of the end face of the connector is liable to damage the transmitter and receiver elements Page 8 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors Grinding and Polishing BFOC Connectors To grind the BFOC connector insert it in the black polishing disc Grind down the excess fiber by describing a figure of eight on polishing paper 400 grit on a flat solid surface by applying gentle pressure to the connector Remove the connector from the polishing disc and remove the debris with a soft lint free cloth Fit the connector into the white polishing Finally place the light gray polishing disc paper 1500 grit on a firm flat surface and polish the connector end face by describing a figure of eight while applying gentle pressure to the connector Repeat the figure of eight movement approximately 25 times Remove the connector from the polishing disc and remove the debris with a so
206. e warnings and safety instructions Only operate the modules with a safety extra low voltage in accordance with IEC 950 EN 60 950 VDE 0805 with a maximum rating of 32 V typically 24 V The power source must comply with NEC Class 2 regulations as stipulated by UL CSA Pay attention to the electrical limit values when connecting the power supply to the signaling contacts max voltage 60 V DC 42 V AC The connected power supply must also be safety extra low voltage in accordance with IEC 950 EN 60 950 VDE 0805 and comply with NEC Class 2 regulations as stipulated by UL CSA A DANGER Never connect the PROFIBUS OLM to the main power supply AN Only install the device in a location where the climatic and mechanical limit values given in the Technical Data can be complied with A WARNING Do not look directly into the aperture of the optical transmitting diode or the optical fiber The light beam which is emitted could endanger your eyesight OLM P11 The optical radiated power of the com OLM P12 ponents used in this device does not OLM G11 1300 represent a potential health hazard of any OLM G12 1300 description under normal foreseeable conditions and it complies with Class 1 in accordance with IEC 60825 1 1994 A1 1997 resp the Degree of Endangerment 1 in accordance with IEC 60825 2 1993 OLM G11 Non visible LED radiation OLM G12 Do not look into the beam not even with OLM G12 EEC optical instruments LED class 1M Classificati
207. e when using S5 CH2 T plastic optical fiber cables to CH3 i Switch S5 to Position 0 reduced if overloading is detected at a non OLM device when using plastic optical fiber cables to CH2 Note The DIL switches S5 and S6 on the OLM for glass optical fiber cables do not have a function the optical transmitting power cannot be reduced The transmitting power default setting S5 or S6 in Position 1 must be set when using PCF fibers Version 1 1 8 00 19 4 Setting Up 4 4 Installation 4 4 Installation 4 4 1 Connecting the optical lines Fig 6 View of the bottom of the module with 20 FI TI TI H TI 7 H 7 H 7 p T_T E E E E E E E E S S EE Le the optical ports 2 and 3 device with two optical ports Connect the individual modules using a dual fiber optical fiber line with BFOC 2 5 connectors Ensure that the end faces of the optical plugs are free of contamination that respectively one optical input and one optical output G gt are connected to one another crossover connection The BFOC port sockets which belong to one other are marked on the bottom of the front plate that the optical plugs on the BFOC socket are securely attached bayonet fastener must be slotted in Ensure that there is sufficient strain relief on the optical fiber line and pay attention to the minimum bend radius Seal BFOC sockets which have not been
208. eare disturbi grazie ad appositi filtri integrati e Facile allineamento grazie a copertura della superficie angolo di apertura 10 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti senza fili Funzioni L ILM permette il collegamento senza fili di slave PROFIBUS con un raggio di azione di 15 m possibile la comunicazione con diversi slave Eventuali interru zioni della trasmissione vengono identificate e visualizzate con LED e contatto di segnalazione Il peggioramento della qualit della trasmissione segnalato da LED e contatto di segnalazione prima dell interruzione definitiva L impiego con la luce del giorno possibile grazie ad un filtro integrato che pro tegge dalla luce di disturbo Durante il montaggio dei Infrared Link Module neces sario fare attenzione che tra i moduli vi sia un collegamento a vista senza interru zioni In caso di impiego di pi linee di trasmissione ILM necessario impedire che le linee si disturbino reciprocamente utilizzando strutture intermedie e rispettando le distanze minime Dati per l ordinazione PROFIBUS ILM N di ordinazione 6GK1 503 0AA00 Infrared Link Module per il collegamento senza fili di nodi e segmenti PROFIBUS Istruzioni per l uso Le istruzioni per l uso complete si trovano nell appendice del persente manuale Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 9 3 Reti PROFIBUS SIMATIC
209. eca integrato e barriera integrata L accoppiatore DP PA Ex i 6ES7 157 0AD80 0XA0 presenta le seguenti diffe renze dall accoppiatore DP PA EX i 6ES7 157 0AD00 0XA0 e Tipo di protezione da scintille EEx ib II C e Condizioni ambientali ampliate SIMATIC outdoor Progettazione dell accoppiatore DP PA e L accoppiatore DP PA pu essere impiegato in SIMATIC S5 e S7 e per tutti i master DP che supportano 45 45 kbit s e L accoppiatore DP PA non deve essere progettato necessario impostare solo la velocit di trasmissione di 45 45 kbit s per la rete DP interessata durante la progettazione Successivamente progettare le apparecchiature da campo come normali slave con lo strumento di progettazione DP e il relativo file GSD Le apparecchiature da campo PA possono essere configurare con SIMATIC PDM o con un altro strumento software specifico del costrutture 2 5 4 DP PA Link Definizione Il DP PA Link composto dall IM 157 e da max cinque accoppiatori DP PA Il DP PA Link uno slave DP sul lato PROFIBUS DP e un master PA sul lato PROFIBUS PA Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 23 Topologie delle reti SIMATIC NET PROFIBUS Settore d impiego DP PA Link mette a disposizione un collegamento disaccoppiato di PROFIBUS PA a PROFIBUS DP con velocit di trasmissione da 9 6 kbit s a 12 Mbit s DP PA Link pu essere inserito esclusivamente in SIMATIC S7 La seguente figura 2 16
210. eck the contents of frames but can only monitor the basic functions and optical transmission quality 43 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 10 2 Errors Due to Incorrect Network Configuration In large PROFIBUS networks with numerous modules and long cable lengths the delay caused by network components and cables transmission delay must be taken into account when setting the monitoring times If you do not take these delay times into account problems will occur during operation In such situations the active partner does not receive a response to a request within the slot time of PROFIBUS because this has been configured too short In large networks or networks with looped in active components the transmission delay time TTD must be calculated to allow correct configuration The transmission delay time is the maximum time that can elapse during the transmission of a frame between the sender and receiver on the transmission medium Note If the configuration software you have used to configure your PROFIBUS network does not support the PRO FIBUS parameter TTD increase the two times min TSDR and max TSDR in each case by 2x TTD the reac tion time of the responder is increased by the transmission delay time for the outward and return path 10 2 1 Calculating the Propagation Time on Electric Cables and Fiber Optic Cables The propagation times on electrical cables or fiber optic cable
211. ed to trigger the signaling contact gt Too much extraneous light at the optical receiver if this was configured to trigger the signaling contact gt Receive level low at optical receiver if this was configured to trigger the signaling contact The signaling contact has no electrical connection to any other components of the PROFIBUS ILM Limit values of the relay gt Maximum switching power 30 W gt Maximum switching voltage 30V DC gt Maximum switching current 1 0A The voltage connected to the signaling contact must be a safety extra low voltage complying with IEC 950 EN 60 950 VDE 0805 According to the CUL approval you should connect the signalling contact only at the load side of a Class 2 or Class 3 power source as defined by the National Electric Code NEC Article 725 2 and the Canadian Electrical Code CEC 39 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 9 Displays green LED No power supply or internal power supply defective or ribbon ca ble not plugged in lit green Power supply OK TX yellow orange LED not lit Data not sent optically lit yellow Data are sent acknowledgment bit correctly received or acknow ledgment bit mechanism not activated lit orange Data being sent acknowledgment bit activated but not correctly received RX yellow LED not lit Data not optically received lit yellow Data optically received LOW red LED not lit Receive level OK RX LED lit no
212. ei conduttori nei morsetti a vite in caso di conduttori a trefoli utilizzare capicorda con 0 25 mm secondo DIN 46228 e Fare attenzione che lo schermo a maglia appoggi completamente sulle superfici di contatto del connettore e Applicare il coperchio del contenitore e avvitarlo e Attivare per i connettore di bus la terminazione del cavo su un estremit del segmento Avvertenza conduttori a trefoli possono essere avvitati solo con l aiuto di capicorda 0 25 mm secondo DIN 46228 Utilizzare solo copicorda di materiale con propriet di contatto a stabilit permanente p es rame con superficie stagnata non alluminio Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 45 Componenti passivi per reti RS 485 4 6 Innesto del bus sull unit Collegamento del connettore di bus Per collegare il connettore di bus procedere nel modo seguente 1 Innestare il connettore di bus sull unit 2 Avvitare il connettore di bus all unit 3 Se il connettore di bus si trova all inizio o alla fine di un segmento necessario attivare la resistenza terminale interruttore in posizione ON vedere fi gura 4 26 La resistenza terminale non pu essere attivata per il connettore di bus 6ES7 972 0BA30 0XAO0 Avvertenza Fare attenzione che e attivando la resistenza terminale il cavo di bus in partenza viene separato dal cavo di bus in arrivo e le stazioni sulle quali si trova una resist
213. eiver is separated from the other ports from the moment a frame is sent until the echo has been received correctly Segmentation If an echo monitoring error or a frame falsification arises at an optical port the module assumes that the line is faulty and blocks this port for user data The connected field bus partial network is then segmented cut off This segmen tation causes the module at the other end of the optical fiber to be segmented as well Both modules connected to the segmented field bus partial network send test frames to the segmented ports These test frames which are to be received regularly can be used by both modules to check the status of the field bus partial network The segmentation is automatically lifted as soon as the test frames indicate to both modules that the segmented field bus partial network is no longer disturbed If all active bus subscribers are deactivated in a previously active network the modules are segmented cyclically in order to check the fiber links to the neighboring modules If there is no frame traffic but the fiber links are intact the port LEDs of the optical ports flash yellow cyclically 8 Version 1 1 8 00 3 Network Topologies 3 1 Line topology 3 Network Topologies The following network topologies can be realized with the PROFIBUS OLM Point to point connections Line topologies Star topologies Redundant optical rings Combinations of these basic types are also possible
214. eld bus networks They enable electrical PROFIBUS interfaces RS 485 level to be converted into optical PROFIBUS interfaces and vice versa By profiting from the familiar advantages of optical transmission technology the modules can be integrated into existing PROFIBUS field bus networks A complete PROFIBUS field bus network with modules in line star or ring topology and an arbitrary combination of these can also be built up The redundant ring is also supported thereby increasing the fail safety of the field bus network Each module has two or three mutually independent ports which in tum consist of a transmitting and a receiving component The device is powered by 24V DC voltage A redundant feed increases operational safety The electric port is a 9 pole Sub D socket female An RS 485 bus segment in line with the PROFIBUS standard EN 50170 can be connected to this port The optical fibers are connected using BFOC 2 5 connectors Four multicolored light emitting diodes indicate the current operating status and possible operating malfunctions Operating voltage supply signaling contact 5 pole terminal block LED Indicators 000 Measuring sockets Port 1 electric Sub D socket RD ul optical optical Fig 1 PROFIBUS OLM module showing the location of the
215. ella rete Segmento Il cavo di bus tra due resistenze terminali forma un segmento Un segmento comprende accoppiamenti di bus massimi gt nodi gt Repeater RS 485 gt OLM I segmenti possono essere accoppiati con repeater RS 485 Sistema di bus Tutte le stazioni collegate fisicamente con un cavo di bus formano un sistema di bus Tempo di propagazione del segnale Tempo di cui necessita un pacchetto dati per percorrere la rete Tempo di reazione Il tempo di reazione il tempo medio che trascorre tra la modifica in un ingresso e la relativa modifica di un uscita Terra La terra il terreno con funzione di conduzione il cui potenziale viene azzerato ad ogni punto Slave Uno slave pu scambiare dati con il master solo su richiesta del master stesso Slave sono p es tutti gli save DP come ET 200S ET 200X ecc SOFTNET per PROFIBUS SOFTNET per PROFIBUS il software di protocollo per le unit SIMATIC NET PC CP 5511 e CP 5611 Reti PROFIBUS SIMATIC NET Glossar 6 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Glossario Tempo di circolazione del token il tempo che trascorre tra la ricezione del token e la ricezione del token suc cessivo Terminator Resistenza terminale di segmenti di bus con velocit di trasmissione com prese tra 9 6 kbit s e 12 Mbit s l alimentazione avviene indipendentemente dal nodo di bus Token un telegramma che rappres
216. elle seguenti specificazioni viene presupposto che tutti i componenti all interno di un sistema di automazione e tutti i componenti dell impianto comandati da esso p es macchine robot ecc rispondano ai requisiti delle norme europee di compati bilit elettromagnetica per ambienti industriali In caso di apparecchi difettosi o in stallati in modo errato necessario calcolare tensioni di disturbo maggiori necessario che e icavi per segnali analogici segnali di dati e segnali di processo siano sempre schermati e i cavi non siano ad una distanza maggiore di 10 cm dalla superficie di massa del sistema parete dell armadio canale per cavi collegato a terra Avvertenza Generalmente il pericolo di disturbi dovuti a diafonia tanto ridotto quanto mag giore la distanza tra i cavi e quanto pi corte sono le linee sulle quali sono instal lati parallelamente i cavi Tabella delle distanze La tabella C 1 fornisce informazioni relative alle regole generali di distanza per la scelta dei cavi Queste regole rappresentano i requisiti minimi per il posiziona mento di cavi di bus all interno di edifici all interno o fuori da armadi Indicazioni per la lettura della tabella Per sapere come installare due cavi di diverso tipo procedere nel modo seguente 1 Cercare il tipo di cavo per il primo cavo nella colonna 1 cavi per 2 Cercare il tipo di cavo per il secondo cavo nella relativa sezione della co
217. enitore compatto di 70 mm per il montaggio su una guida ad U Il montaggio va eseguite preferibilmente in posizione verticale moduli possono essere collegati in riga e direttamente uno di fuanco all altro L allacciamento a PROFIBUS DP viene eseguito con un connettore femmina Sub D a 9 poli L interfaccia RS 232C costituita da un connettore Sub D a 9 poli Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 27 Topologie delle reti SIMATIC NET PROFIBUS Settore d impiego Il PROFIBUS DP RS 232C Link un converitore tra un interfaccia RS 232C V 24 e PROFIBUS DP Gli apparecchi con un interfaccia RS 232C possono essere accoppiati a PROFIBUS DP con il DP RS 232C Link Il DP RS 232C Link supporta le procedure 3964 R e il protocollo libero ASCII Progettazione Master S7 400 con STEP 7 Mi f H ANO IL PROFIBUS DP Cavo di bus PROFIBUS SIEMENS DP RS 232C Link Apparecchi O RS 232C Procedura seriale ee Figura 2 19 Esempio di configurazione per DP RS 232C Link Tipo di funzionamento Il PROFIBUS DP RS 232C Link viene collegato all apparecchio tramite un collegamento punto a punto Nel PROFIBUS DP RS 232C Link viene eseguita la conversione a protocollo PROFIBUS DP dati vengono trasmessi in modo consistente in entrambe le direzioni Per ogni telegramma possono e
218. enta l autorizzazione di trasmissione in una rete Esso segnala gli stati occupato o libero Il token viene inoltrato da master a master Troy Tempo a disposizione per la conferma o la risposta ready time Tset a Tempo di azionamento Setup Time Il tempo di azionamento il tempo che pu trascorrere tra la ricezione di un telegramma di dati e la reazione Ts cs Tempo di attesa della ricezione slot time il tempo massimo che attende il tras mettitore per la risposta della stazione interrogata T r Tempo di circolazione del token nominale Target Rotation Time Ogni master confronta il tempo di circolazione dl token nominale con il tempo di circolazione del token reale Dalla dfferenza risulta di quanto tempo necessita il master DP per la trasmissione di telegrammi di dati agli slave Unit PC SIMATIC NET Unit PC SIMATIC NET sono unit per l accoppiamento del PC a sistemi di bus come p es PROFIBUS o Industrial Ethernet Velocit di trasmissione La velocit di trasmissione indica il numero di bit trasmessi al secondo Con PROFIBUS sono possibili le velocit di trasmissione comprese tra 9 6 kbit s e 12 Mbit s Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Glossar 7 Glossario Reti PROFIBUS SIMATIC NET Glossar 8 6GK1970 5CA20 0AA4 Edizione 2 05 2000 A D Alimentatore 2 23 Dati tecnici secondo il modello FISCO 2 23 Connettore di bus 4 35 PROFIBUS Termin
219. entano una separazione di potenziale tra loro e segnali vengono rinforzati tra il segmento di bus 1 e il segmento di bus 2 tra il connettore femmina PG OP e il segmento di bus 2 Segmento 1 Segmento 2 Al i gt A2 D gt Logica lt All B1 4 J Hs B2 _ Al I A2 B1 B2 _4 Connettore 5V a 1M femmina E SE oH 24V 24V PG OP L 24 V L 24 V M M Al L PE B1 M 5 2 5V M5 VT ar Figura 5 1 Schema elettrico del repeater RS 485 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 5 5 Componenti attivi per reti RS485 5 2 Possibilit di configurazione con il repeater RS 485 Panoramica Il seguente capitolo illustra le configurazioni nelle quali possibile utilizzare il re peater RS 485 e Segmento 1 e segmento 2 chiusi sul repeater RS 485 vedere figura 5 3 e Segmento 1 chiuso sul repeater RS 485 e segmento 2 passante sul repeater RS 485 vedere figura 5 4 e e Segmento 1 e segmento 2 passanti sul repeater RS 485 vedere figura 5 5 Attivazione disattivazione della resistenza terminale La figura 5 2 illustra la posizione della resistenza terminale Resistenza terminale Resistenza terminale attivata di
220. enza terminale sono sem pre alimentate durante l avvio e il funzionamento del bus Resistenza termi on Resistenza terminale Kon nale attivata non attivata Figura 4 26 Connettore di bus 6ES7 972 0B 11 resistenza terminale attivata e disatti vata Sfilare il connettore di bus Il connettore di bus con cavo di bus collegato in cascata pu essere sfilato dall interfaccia PROFIBUS DP in qualsiasi momento senza interrompere il traffico di dati sul bus Reti PROFIBUS SIMATIC NET 4 46 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 N Pericolo Possibilit di disturbo del traffico di dati sul bus Un segmento di bus deve essere sempre chiuso su entrambe le estre mit con la resistenza terminale Questa operazione non deve p es essere eseguita se l ultimo nodo con il connettore di bus senza ten sione Poich il connettore di bus preleva la propria tensione dalla sta zione la resistenza terminale senza effetto Fare attenzione che le stazioni sulle quali attivata la resistenza termi nale sia sempre presente tensione In alternativa possibile inserire anche il PROFIBUS Terminator come terminazione attiva del bus vedere capitolo 5 7 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 47 Componenti passivi per reti RS 485 4 7 Bus terminal per reti RS 485 4 7 1 Panoramica Versioni alternative Un bus terminal serv
221. ers for use in balanced digital multipoint systems Copyright by Siemens 52 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Product name Infrared Link Module ILM Order no 6GK1 503 0AA00 The SIMATIC NET product named above meets the reuirements of the following EU directives EMC 89 336 EEC Directive 89 336 EEC Electromagnetic Compatibility Area of application The product is designed for operation in an industrial and domestic environment Area of application Requirements Noise emission Noise immunity Industrial EN 50081 2 1993 EN 50082 2 1995 Domestic business and workshop EN 50081 1 1992 EN 50082 1 1997 Conformity Certificates The EU conformity certificates are available for the relevant authorities according to the EU directive and are kept at the following address Siemens Aktiengesellschaft A amp D PT2 Industrielle Kommunikation Postfach 4848 D 90327 N rnberg Directive on Machines The product remains a component in compliance with Article 4 2 of the EU directive on machines 89 392 EEC According to the directive on machines we are obliged to point out that this product is intended solely for installation in a machine Before the final product is started up it mustbe established that it conforms to the directive 89 392EEC Installation Guidelines The product meets the requirements providing you adhere to the guidelines for installation and operation in the docu
222. ervice est interdite tant que la machine dans laquelle est incorpor ce composant n est pas conforme aux prescrip tions de la directive 89 392 CEE Attenzione Primadella messa in funzione osservare attentamente le avvertenze riportate nella documentazione corrente Peri dati di ordina zione consultare i cataloghi oppure rivolgersi alla locale fidale SIEMENS La messa in funzione vietata fino a quando non stato acctertato che macchina in cui il componente deve essere installato non rispetta le disposizioni della direttiva 89 392 CCE Atenci n Antes de la puesta en marcha observar las indicaciones contenidas en la documentatci n actual correspondiente La referencia de la misma puede consultarse en los cat loges o solicitarse a su agencia SIEMENS local Esta prohibida la puesta en marcha hast comprobar que la maquina en donde ca a incorporarse este componente cumpie lo especificado en la directiva 89 392 CCE 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Wir haben den Inhalt der Druckschrift auf bereinstimmung mit der beschriebenen Hardware gepruft Dennoch k nnen Abweichungen nicht ausgeschlossen werden so da wir f r die vollst ndige bereinstimmung keine Gew hr bernehmen Die Angaben in der Druckschrift werden jedoch regelm ig berpr ft Notwendige Korrekturen sind in den nachfolgenden Auflagen enthalten F r Verbesserungsvorschl ge sind wir dankbar Technische nderungen vorbehalten Weitergabe sowie
223. es too much extraneous light which always causes Copyright by Siemens 28 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM transmission errors The red LOW LED should only be lit when the level on the infrared link is close to the minimum receive level operation at the edge of the illumination cone Check the data exchange for incorrect data using SCOPE for PROFIBUS TMG i tec a tool for diagnostics on PROFIBUS networks 29 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 8 Installing the PROFIBUS ILM The PROFIBUS ILM can be mounted with two screws on a flat surface approximately 180 x 80 mm This can be a wall amounting plate or the surface of a device or vehicle The holes in the PROFIBUS ILM are intended for screws with a thread diameter of maximum 4 5 mm and a screw head diameter of maximum 8 5 mm Figure 11 shows the location of the holes drilled in the ILM Mounting hole 2 Mounting hole 1 Figure 11 Dimensions for Securing the PROFIBUS ILM to a Mounting Plate Select the site for installing the module so that the climatic limit values and mechanical stress values as described in the technical specifications are adhered to When installing the module make sure in particular that no direct sunlight falls on the device otherwise both the temperature r
224. essere realizzate sia strutture lineari sia ad albero La figura 2 1 illustra una topologia caratteristica della tecnica RS 485 con 3 seg menti e 2 repeater ii Ni oh Figura 2 1 S7 400 Mi Repeater i H mi vazione Soi ig Casi To j Repeater RS 485 Resistenza terminale attivata PG per interventi di manutenzione allacciato tramite cavo di derivazione 6ES7 901 4BD00 0XA0 Topologia con tecnica RS 485 In caso di strutture estese con repeater si verificano tempi di trasmissione maggiori che vanno eventualmente tenuti in considerazione durante la progettazione della rete vedere capitolo 3 Componenti per velocit di trasmissione fino a 1 5 Mbit s Tutti i componenti di allacciamento del bus SIMATIC NET possono essere impie gati per velocit di trasmissione lt 1 5 Mbit s Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS 2 1 2 Componenti per velocit di trasmissione fino a 12 Mbit s seguenti componenti di allacciamento del
225. eti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 19 Componenti passivi per reti ottiche Impiego Il cavo flessibile da trascinamento Fiber Optic stato concepito per applicazioni speciali che richiedono il trascinamento come p es da parti di macchine in conti nuo movimento catene portacavi Esso progettato per 100 000 cicli di curvatura di 90 con il raggio minimo specificato Il cavo da trascinamento pu essere impiegato sia all interno sia all esterno Esso adatto per il collegamento di inter facce ottiche che lavorano con campo di lunghezza d onda compreso tra 850 nm e 1300 nm Reti PROFIBUS SIMATIC NET 7 20 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche N Pericolo Durante la posa e il funzionamento amp necessario osservare tutti i requisiti mecca nici del cavo come i raggi di curvatura le forze di tiro ecc Il superamento di questi valori pu compromettere le propriet di trasmissione conducendo eventualmente all interruzione parziale o completa della trasmissione dei dati AR W A It Il DE RUI il Figura 7 7 Esempio di impiego del cavo da trascinamento in fibra ottica di vetro in una catena portacavi Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 21 Componenti passivi per reti ottiche 7 3 4 Cavo marino duplex in fibra ottica SIENOPYR Conduttore in rame Isolamento Fibra ottica Scarico di tiro Rivesti
226. eti ottiche 0 0 cece eee eee 7 1 7 1 Cavo in fibra ottica 7 2 Cavi in fibra ottica di plastica 7 2 1 Plastic Fiber Optic conduttori duplex 7 2 2 Plastic Fiber Optic cavi standard 0 cc cece eee nes 7 2 3 Cavo in fibra ottica di POF 7 3 Cavo in fibra ottica di vetro 0 eee 7 3 1 Cavo standard Fiber Optic 000 cee eect eee ee 7 3 2 Cavo per installazione all interno di edifici INDOOR Fiber Optic 7 3 3 Cavo da trascinamento Flexible Fiber Optic 7 3 4 Cavo marino duplex in fibra ottica SIENOPYR 7 3 5 Cavi speciali de ee ea 7 4 Connettori per cavi FO 7 4 1 Connettore per cavi in fibra ottica di plastica 7 4 2 Connettore simplex e adattatori per apparecchi con interfacce ottiche integrate eee 7 4 3 Connettore BFOC per OLM c eee 7 4 4 Connettore per FO in vetro 20 c eee 8 Componenti attivi per reti ottiche 0 cece 8 1 Bus terminal ottico OBT 0 00 ccc eee 8 2 Optical Link Module OLM 0 ccc cece etn e nee 9 Componenti attivi per reti senza fili 0 cece eee 9 1 Infrared Link Module ILM 0 0 0 0 cece eee A TECNICA DI MISURA PROFIBUS 0 ccc cucu e cece nn nun nn nun eee A 1 Dispositivo di test hardware BT 200 per PROFIBUS DP A 1 1 Possibilit di IMpiego 0 A 1 2 S
227. ettore d impiego 2 kk tenets A 1 3 Funzioni di protocollo 0 00 cece teens A 1 4 Struttura io ai ei ie ia e ie A 1 5 FUNZIONI LL A 1 6 Tipo di funzionamento eee teens A 2 Tecnica di misura per FO A 2 1 Necessit di una misurazione conclusiva A 2 2 Metodo di attraversamento di raggi luminosi A 2 3 Reflettometro OTDR cc cece ccc eee ete een eens A 2 4 Controllo della qualita del segnale ottico per PROFIBUS OLM V3 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Protezione contro fulmini e sovratensioni per cavi di bus che si estendono in piu edifici u a ea a a B 1 Per quale motivo necessario proteggere il sistema di automazione da sovra TENSIONI protiro lat er B 2 Protezione antifulmine di cavi di bus LL B 2 1 Istruzioni di installazione per protezione di massima B 2 2 Istruzioni di installazione per protezione di fine B 2 3 Istruzioni generali per il dispositivo di protezione antifulmine della ditta Dehn amp S hne eee tenes Installazione dei cavi di DUS 00 ccc eee eee eee C 1 Cavi di bus in impianti di automazione 0 c cece C 2 Sicurezza elettrica teeta C 3 Protezione meccanica dei cavi di bus eee ee C 4 Compatibilit elettromagnetica dei cavi di bus nnn C 4 1 Provvedimenti di protezione cont
228. ezze del segmento limitate Velocit di trasmissione 31 25 kbit s il cavo corrisponde al modello FISCO Lunghezza del cavo 180 Reti PROFIBUS SIMATIC NET 4 6 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 1 1 Conduttore interno in rame massiccio Protezione di isolamento FC Standard Cable cavo standard Guaina esterna in PVC Schermo a maglia in rame Foglio di schermatura in alluminio oglio in materiale sintetico in PE cellulato Materiale di riempimento Figura 4 1 Principio di struttura del cavo standard FC Cavo standard FC 6XV1 830 0EH10 Propriet Impiego Il cavo di bus 6XV1 830 0EH10 il cavo elettrico standard FastConnect per reti PROFIBUS Esso soddisfa i requisiti di EN 50170 tipo di cavo A con conduttori in rame massiccio AWG 22 La combinazione di intreccio di conduttori schermo a foglio e schermo a maglia li rende particolarmente adatti per l installazione in ambiente industriale con disturbi elettromagnetici La struttura garantisce inoltre un elevata stabilit delle propriet elettriche e meccaniche dopo l installazione Il cavo di bus FastConnect 6XV1 830 0EH10 omologato UL La struttura del cavo permette l impiego del FastConnect FC Stripping Tool per lo spostamento rapido del cavo vedere capitolo 4 2 3 Grazie alla speciale composizione mista del materiale della guaina il cavo di bus e difficilmente infiammabile e
229. ezzo di tubo di prote zione risvoltato Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 21 Installazione dei cavi di bus Applicazione dello scarico di tiro Applicare per tutti i cavi che vengono sottoposti a trazione uno scarico di tiro a ca 1 m dal punto di allacciamento punti di collegamento dello schermo non solo suf ficienti come scarico di tiro Carichi di pressione Torsione Evitare un eccessiva pressione dei cavi di bus dovuta p es a schiacciamento in seguito ad un fissaggio inadeguato La torsione pu comportare uno spostamento dei singoli elementi dei cavi e di con seguenza compromettere le propriet elettriche degli stessi Per questo motivo i cavi di bus non devono essere torsi Non sottoporre a torsione i cavi da trascinamento e a festoni Installare i cavi da trascinamento SIMATIC NET e i cavi a festoni SIMATIC NET completamente senza torsioni L installazione corretta pu essere controllata gra zie ad una linea stampata in senso longitudinale sulla guaina esterna del cavo Un installazione del cavo eseguita con torsioni pu comportare in combinazione con movimenti dei cavi durante il trascinamento danni precoci del cavo Cavo flessibile per sollecitazione a torsioni Per le applicazioni nelle quali necessaria una sollecitazione a torsione del cavo di bus durante il funzionamento p es robot impiegare il cavo resistente a torsione SIMATIC NET Questo cavo des
230. ft lint free cloth Repeat this procedure with the second connector Page 9 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors Marking of the SIMATIC NET PROFIBUS plastic fiber optic standard cable To help you connect up the cable correctly the standard cable has arrow markings on the orange cord This helps to make sure that you attach one end of a cord to the transmitter and the other to a receiver crossed over cords First connect the orange cord The black cord is then connected to the e If the arrow on the orange cord is free socket of the same FO interface pointing out of the cable connect this cord to the receiver The receiver is identified by an arrow pointing into a circle If the arrow on the orange cord points into the cable picture connect this cord to the transmitter The transmitter is identified by an arrow pointing out of a circle Page 10 SIMATIC NET PROFIBUS Plastic Fiber Optic Cables Tools and Accessories SIMATIC NET PROFIBUS Plastic Fiber Optic standard cable I VYA4Y2P 980 1000 160A Robust round cable with 2 plastic FO cords violet outer jacket and PA inner jacket without connector for use indoors In meters 6XV1 821 0AH10 50 m Ring 6XV1 821 0AN50 100 m Ring 6XV1 821 0AT10 SIMATIC NET PROFIBUS Plastic Fiber Optic duplex cord I VY2P 980 1000 150A Plastic FO cable with two cords PVC jacket without connectors for u
231. g contact not activated by extraneous light LER 7 Signaling contact activated by extraneous light 8 Signaling contact not activated by low receive level Signaling contact activated by low receive le vel Figure 10 Configuration for Triggering the Signaling Contact Copyright by Siemens 26 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 7 VVVYV N Installation and Startup Notes on Safety Use the PROFIBUS ILM only as described in this description and operating instructions Never connect the PROFIBUS ILM to the mains power supply 110 V 240 V In particular take note of all the warnings and notes relating to safety The operating voltage must be a safety extra low voltage complying with IEC 950 EN 60 950 VDE 0805 of maximum 30V typically 24 V According the CUL approval you should connect the PROFIBUS ILM only at the load side of a Class 2 or Class 3 Power source as defined by the National Electric Code NEC Article 725 2 and the Canadian Electrical Code CEC The voltage connected to the signalling contact must be a safe extra low voltage complying with IEC 950 EN 60 950 VDE 0805 According the CUL approval you should connect the signalling contact only at the load side of a Class 2 or Class 3 power source as defined by the National Electric Code NEC Article 725 2 and the Canadian Electrical Code CEC Wiring the PROFIBUS ILM pay attention to the wiring methods described in NEC article 725 52 725
232. g resistors in the bus port connectors see 4 4 3 Connecting the electric RS 485 bus lines p 22 at both ends of the electrical star segment Do not connect a bus subscriber to the electrical star segment wherever possible Modules with one or two optical ports can be used to create an active PROFIBUS star coupler Modules with one optical port are sufficient for connecting a terminal or an RS 485 bus segment to the active star coupler If the link monitoring on the optical ports is activated the fiber optic links are monitored by the respectively connected OLM Note Optical ports which are not assigned for instance because they are reserved for a future system extension indicate a fiber break if the link monitoring is activated You can prevent this error report from being issued by activating the operating mode Line without fiber link monito ring at the non assigned ports Please note that optical ports which are not connected must always be fitted with protective caps to guard against extraneous light and dirt 3 3 Redundant optical ring U OY HE FE RE a a a iy 22 2 gt RS 485 bus line CH 2 CH 3 CH 2 CH 3 CH 2 CH 3 lt OLM P12 OLM P12 OLM P12 OLM P12 Optical fiber OLM G12 1300 OLM G12 1300 OLM G12 1300 OLM G12 1300
233. go all interno di edifici quindi protetto contro le intermperie Esso adatto per il collegamento di interfacce ottiche che lavorano con campo di lunghezza d onda compreso tra 850 nm e 1300 nm Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche 7 3 3 Cavo da trascinamento Flexible Fiber Optic Guaina esterna Filati aramidici Tessuto cordatura Elemento di supporto Elemento di supporto Guaina interna Filati aramidici Fibra di vetro G 62 5 125 u Figura 7 6 Struttura del cavo flessibile da trascinamento Fiber Optic Cavo flessibile da trascinamento Fiber Optic 6XV1820 6 Il cavo da trascinamento flessibile Fiber Optic composto da 2 fibre a gradiente d indice multimode 62 5 125 um Gli elementi di supporto preformati creano una sezione rotonda del cavo La guaina esterna riporta la scritta SIEMENS SIMATIC NET FLEXIBLE FIBER OPTIC 6XV1 820 6AH10 ogni ca 50 cm La marcatura in metri consiste in un trattino verticale e un numero a 4 cifre che facilita il calcolo della lunghezza di un cavo installato Propriet Il cavo flessibile da trascinamento Flexible Fiber Optic presenta le seguenti pro priet e alta flessibilit 100 000 cicli di curvatura con un raggio minimo di curvatura di 150 mm e non esente da alogeni e disponibile a metraggio con lunghezze fino a 2000 m e confezionato con 4 connettori BFOC disponibile in lunghezze stabilite fino a 650 m R
234. gth of the outer jacket The polishing holder has four recesses on the bottom surface Replace the polishing holder as soon as any of these recesses is no longer visible Never insert contaminated connectors or connectors with fibers extending beyond the end face into the device sockets The optical transmitter and receiver elements could otherwise be destroyed When assembling plug adapters and when fitting the cable to them make sure that the transmit and receive lines are crossed over Page 3 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors Plug adapters are designed for fitting preassembled cords once If a cord has been inserted and must be removed again the bent cord section must not be used again Cut off the bent cord section and refit the simplex connector Page 4 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors Setting the Cutting Depth of the Cable Knife Set the cutting depth of the cable knife The cutting depth is set using the for stripping the outer jacket of the adjusting screw at the end of the handle SIMATIC NET PLASTIC FIBER OPTIC standard cable to a depth of 1 5 mm Then follow the steps as described below Try out the cutting depth Press the clamp of the cable knife in the the cutting depth e Turning the screw counter clockwise reduces the cutting depth Rotate the cable knife twice
235. he di plastica lunghezza max 50 m o cavi a fibre ottiche PCF lunghezza max 300 m cavi a fibre ottiche sono confezionati su entrambi i lati con due connettori simplex Il collegamento dei cavi a fibre ottiche tra due dispositivi viene stabilito collegando il trasmettitore ottico di un dispositivo con una fibra al ricevitore ottico dell altro dis positivo e viceversa il ricevitore ottico di un dispositivo al trasmettitore ottico dell al tro dispositivo cavo incrociato Se un OBT o un cavo FO dovesse guastarsi l intera rete viene divisa in due reti parziali A seconda del punto del disturbo non pi possibile accedere ai singoli dispositivi L OBT non supporta il montaggio di anelli monofibra linee ottiche sorvegliate o di strutture ad anello ridondante PROFIBUS Optical Busterminal OBT 4 1 C79000 G8972 C1 22 02 Topologia della rete 4 2 Collegamenti di lunghi percorsi di cavi a fibre ottiche Per OBT la lunghezza massima ammessa di cavi a fibre ottiche PCF di 300 m Se dovessero essere necessare lunghezze superiori di cavi FO o altri tipi di FO come p es fibre a gradiente di vetro o fibre monomodali il loro inserimento pu essere eseguito con la combinazione di OBT e OLM Optical Link Module In que sto caso l OBT viene collegato all OLM elettricamente p es OBT CH 1 con OLM CH 1 e OLM viene allacciato al percorso lungo di cavi FO Sull altra estre mit del percorso di cavi FO viene esegui
236. he fiber can be damaged by the blade as it is retracted Repeat the same procedure for the second cord Page 8 SIMATIC NET PROFIBUS Plastic Fiber Optic Fitting Simplex Connectors Insert the cord into the simplex plug as far as it will go and close the clamp Caution The fiber must extend at least 1 5 mm beyond the end face of the connector Cut off excessive fiber with scissors leaving approximately 1 5 mm in length The polishing is completed when the fiber is flush with the end face of the connector Remove the debris from the polishing holder and from the end face of the connector using a clean cloth Installation Instructions for Simplex Connectors Close the clamp until you hear the catch Repeat the same procedure for the lock in place Insert the simplex connector into the polishing holder as far as it will go Then polish the end face of the connector by describing figures of eight on the pink polishing foil rough side Repeat the figure of eight movement approximately 25 times Polishing reduces the attenuation by approximately 2 dB corresponds to approximately 10 m cable length With short lengths of cable polishing is Page 9 second cord Caution Do not insert the connector into a device socket otherwise the excess fiber length is liable to damage the transmitter and receiver elements Grind down the excess fiber by describing a figure of eight on polishing paper 600 grit on
237. he optical lines 4 4 2 Mounting the Modules 4 4 3 Connecting the electric RS 485 bus lines 4 4 4 Connecting the power supply LL 4 4 5 Connecting the signaling contact lies 4 4 6 Defining the receiving level of the optical ports LL 5 LED Indicators and Troubleshooting eee e nee e es 5 1 LED Indicators seratona aerea aan 5 2 Troubleshootingi sinvssata fra iia ea a AIR PRA 6 Configuration ii ae ee ee ele eat 6 1 Configuration of optical line and star topologies LL 6 2 Configuration of redundant optical rings 7 Technical Data Gora io ergo nese eed SI res 8 Appendix 0a en a Iii 8 1 CE Designation sare cia ia alora i Ei 8 2 Literaturenotes iui a Ra i a i 8 3 Listofiabbreviations 3 ua wa au cn a E ne dee E bode RE 8 4 Measuring sockets ee eee 8 5 SIMATIC NET Support and Training Version 1 1 8 00 3 Order Numbers SIMATIC NET OLM P11 SIMATIC NET OLM P12 SIMATIC NET OLM G11 SIMATIC NET OLM G12 SIMATIC NET OLM G12 EEC SIMATIC NET OLM G11 1300 SIMATIC NET OLM G12 1300 6GK1 502 2CA00 6GK1 502 3CA00 6GK1 502 2CB00 6GK1 502 3CB00 6GK1 502 3CD00 6GK1 502 2CC00 6GK1 502 3CC00 Version 1 1 8 00 1 Introduction 1 Introduction The PROFIBUS OLM Optical Link Module product family consists of OLM P11 OLM P12 OLM G11 OLM G12 OLM G12 EEC OLM G11 1300 and OLM G12 1300 PROFIBUS OLMSs are designed to be used in optical PROFIBUS fi
238. ht by Siemens 24 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 6 4 Operation with Signaling Contact The signaling contact is used to monitor the PROFIBUS ILM via a digital input on a PLC or as part of a current loop If problems occur the contact opens in other words a connected current loop is then interrupted By setting four switches the user decides which events trigger the signaling contact If more than one problem is configured to trigger the signaling contact the problem cannot be localized using the signaling contact alone In this case the LED displays can also provide information and step by step disabling of the switches that activate the signaling contact can narrow down the problem Note Remember that if you want to activate the signaling contact when the acknowledgment pulse is absent the monitor link with acknowledgment pulse configuration must be activated 25 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 As shipped Setting 0 All switches 0 201 Setting 1 Switch 4 Link monitoring with ack nowledgment pulse must be activated if switch 5 is used Signaling contact not activated if acknowledg ment pulse absent Eon Signaling contact activated if acknowledgment pulse absent fia Signaling contact not activated if no reception or permanent reception Mo Signaling contact activated if no reception or permanent reception Mo Signalin
239. i e la scelta della fibra ottica e lalunghezza d onda dei diodi di trasmissione e il tipo di connessione e per il cavo FO in fibra di vetro dal numero di collegamenti di sdoppiamento compr gli sdoppiamenti dovuti a riparazioni e lalunghezza della fibra ottica lunghezza del cavo e la riserva di attenuazione riserva di sistema della linea di trasmissione p es per l invecchiamento e la sensibilit alla temperatura dei LED e dei fotodiodi Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 13 Progettazione di reti 3 2 2 Bilancio ottico della potenzialit di un sistema di trasmis sione FO Bilancio ottico della potenzialit La potenza di trasmissione Pa e la potenza di ricezione Pe vengono specificate in dBm l attenuazione degli elementi di collegamento e delle fibre ottiche in dB dBm un unit di riferimento e descrive il rapporto logaritmico con la potenza di riferimento Po 1mW Vale la formula P in dBm 10 log P in mW Po Esempi Potenza di Potenza di trasmissione come rapporto trasmissione P logaritmico di potenza P a Po 10 mW 10 dBm 1 mW 0 dBm 1 uW 30 dBm Trasmettitore Ricevitore 3 14 Per i trasmettitori viene specificata in base alla fibra impiegata la potenza minima e massima accoppiabile A questa potenza contrapposta un attenuazione della linea allacciata che viene provocata dalla fibra stessa lunghezza assorbimento dispersione lunghezza d
240. i 12 Mbit s 12 Mbit s 1 5 Mbit s 12 Mbit s trasmissione Resistenza termi integrata integrata no integrata nale e funzione di scollegamento Uscita cavo verticale obliqua a 35 obliqua a 30 assiale Interfacce e verso nodo Connettore Sub D Connettore Sub D Connettore Sub D Connettore Sub D PROFIBUS a 9 poli a 9 poli a 9 poli a 9 poli e verso cavo di 4 morsetti in fila 4 morsetti in fila 4 morsetti da taglio 4 morsetti in fila bus PROFIBUS per fili fino a per fili fino a per fili 0 644 per fili fino a 1 5 mm 1 5 mm 0 04 mm 1 5 mm Allacciabili cavi 8 05mm 8 05mm 8 05mm 8 05mm PROFIBUS con dia metro Tensione di alimen DC 4 75 fino a DC 4 75 fino a DC 4 75 fino a tazione deve prove 5 25 V 5 25 V 5 25 V nire dal terminale di dati Corrente assorbita max 5 mA max 5 mA max 5 mA Condizioni ambien tali ammesse e Temperatura d esercizio e Temperatura di da 0 C a 60 C da 25 C a 80 da 0 C a 60 C da 25 C a 80 da 0 Ca 60 C da0 Ca 55 C da 25 C a 80 da 25 Ca 70 trasporto di ma C C C C gazzinaggio e Umidit relativa max 75 a max 75 a max 75 a max 95 a 25 C 25 C 25 C 25 C Dimensioni in mm 15 81 541 34 161 54x 38 151 58x 34 15 39 57 Peso ca 40g ca 40g ca 30g ca 100g Funzione di scollegamento La funzione di scollegamento provvede a disattivare il cavo che parte dal bus con resistenza terminale a
241. i bus con o senza collegamento per PG e con classe di protezione IP 20 Dispositivo di spegnimento Elementi per la riduzione delle tensioni indotte Le tensioni indotte si presentano disinserendo il circuito elettrico con induttivit Equipotenzialit per la protezione antifulmine L equipotenzialita per la protezione antifulmine comprende i componenti dell im pianto antifulmini necessari per la riduzione della tensione dei fulmini che cau sano differenze di potenziale p es guide equipotenziali cavi equipotenziali morsetti accoppiatori tratti di soaramento delle onde elettromagnetiche condut tore di protezione antifulmine conduttore di protezione contro sovratensioni Fattore GAP Fattore di aggiornamento GAP La distanza tra il proprio indirizzo PROFIBUS del master all indirizzo PROFIBUS successivo di un master viene chiamata gap in glese spazio Il fattore di aggiornamento gap stabilisce dopo quante circolazioni del token il master controlla se nel gap si trova un ulteriore master P es se il fattore di aggiornamento gap 3 significa che ogni master controlla dopo ca 3 circolazioni se tra il proprio indirizzo PROFIBUS e l indirizzo PROFI BUS del master successivo si trova un nuovo master FISCO Il modello elaborato nel PTB in collaborazione con i costruttori pi importati FISCO Fieldbus Intrinsically Safe COncept descrive una possibilit per realiz zare un bus da campo i per l impiego in aree con per
242. i cavi di bus Avvertenza cavi equipotenziali non sono necessari se le parti dell impianto sono collegate tra loro esclusivamente con cavi in fibra ottica FO Reti PROFIBUS SIMATIC NET C 12 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus C 5 Installazione di cavi di bus elettrici Tensioni e correnti Le linee i cavi in un impianto conducono tensioni e correnti A seconda dell applica zione le ampiezze delle linee e dei cavi possono superare di molto la tensione di segnale presente sul cavo di bus Inserendo o disinserendo la tensione di alimen tazione possono verificarsi p es picchi di sovratensione dell ordine di kV Se sono installati altri cavi paralleli al cavo di bus possono verificarsi disturbi nel traffico di dati sui cavi di bus dovuti a diafonia accoppiamento capacitivo o induttivo Per garantire un funzionamento senza disturbi del sistema di bus per l installazione di tutti i cavi vanno osservate determinate specificazioni Per una soppressione dei disturbi molto efficace sufficiente realizzare una distanza possibilmente ampia tra il cavo che genera il disturbo e quello che lo subisce Cavo in fibra ottica Da queste specificazioni sono esclusi i cavi in fibra ottica per i quali durante l in stallazione non necessario osservare le regole di compatibilit elettromagnetica ma solo quelle di sicurezza meccanica Cavi per telecomunicazione C 5 1 Regole particol
243. i cavi di bus devono essere installati insieme ad altri cavi nello stesso canale si consiglia di inserire i cavi di bus pi fragili per ultimi Allacciamento dei cavi PROFIBUS Le istruzioni per l allacciamento dei cavi elettrici PROFIBUS al connettore di bus e ai componenti della rete bus terminal repeater OLM sono riportate nelle de scrizioni e nelle istruzioni per l uso dei relativi componenti Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 23 Installazione dei cavi di bus C 8 Ulteriori avvertenze per l installazione di cavi in fibra ottica Protezione dei connettori contro imbrattamento connettori per cavi in fibra ottica sono sensibili all imbrattamento connettori o i connettori femmina non allacciati devono essere protetti con i cappucci parapol vere forniti Modifica dell attenuazione sotto carico Durante l installazione i cavi FO non devono essere sottoposti a torsione attorci gliati trazione tensione eccessiva o pressione schiacciamento di conse guenza necessario rispettare i valori limite specificati per la sollecitazione a tra zione i raggi di curvatura e i campi di temperatura Durante la posa i valori di attenuazione possono leggermente modificarsi Questi scostamenti sono tuttavia reversibili a condizione che non vengano superati i limiti di carico Utilizzo dell attrezzo di inserimento protezione del connettore cavi in fibra ottica confezionati SIMATIC
244. i componenti PROFIBUS viene combinata in modo ideale all enorme flessibilit del sistema instabus instabus EIB Il DP EIB Link slave DP secondo EN 50170 e contemporaneamente nodo su instabus EIB Gli indicatori e gli elementi di comando sono e LED per errori di bus EIB e LED per errori di bus PROFIBUS e LED per alimentazione OK e Interruttore di codifica per indirizzo PROFIBUS e Tasto di programmazione per EIB Settore d impiego L impiego del DP EIB Link viene preso in considerazione laddove vengono impie gati PROFIBUS o instabus EIB vale a dire che si possono distinguere due settori d impiego Reti PROFIBUS SIMATIC NET 2 34 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Automazione per edifici vale a dire instabus EIB disponibile e si intende impiegarlo per compiti di co mando sovraordinati p es un PLC p es S7 o per Servizio e supervisione so vraordinato p es un sistema HMI Per questo impiego indispensabile l equipag giamento degli edifici destinati ad uffici e ad abilitazioni La possibilit pi semplice per collegare questi sistemi a instabus EIB il DP EIB Link in quanto normalmente i sistemi indicati possono accedere come standard alla periferia tramite PROFIBUS settori di impiego principali sono in questo caso e comando primario regolazione e controllo del riscaldamento e ventilazione climatizzazione HLK e e management e ottimizz
245. i interfacce ottiche che lavorano con un campo di lunghezza d onda com preso tra 850 nm e 1300 nm Fonte di riferimento Gli indirizzi per la consulenza relativa a questo cavo sono riportati nell appendice l 2 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 23 Componenti passivi per reti ottiche 7 3 5 Cavi speciali Cavi speciali Oltre ai cavi standard in fibra ottica SIMATIC NET riportati nel catalogo IK10 esi ste una gran quantit di cavi speciali e di accessori per il montaggio Il numero di pagine del catalogo e di questo manuale non sufficiente per poter descrivere tutte le versioni dati tecnici dei componenti di bus SIMATIC NET specificano i tipi di cavi in fibra ottica SIMATIC NET adatti come standard per il collegamento e gli uteriori tipi di fibra esistenti Avvertenza Fare attenzione che utilizzando fibre con altri diametri del nucleo o altre propriet di attenuazione rispetto ai tipi standard descritti nelle istruzioni per l uso le di stanze realizzabili variano Tipi di fibra 7 24 Oltre ai cavi standard in fibra ottica SIMATIC NET vengono spesso utilizzati anche i seguenti tipi di fibra e Fibra 50 um Questo tipo di fibra viene impiegato in particolare in Europa per la telecomuni cazione al posto della fibra 62 5 um La potenza di trasmissione accoppiabile e di conseguenza la distanza raggiungibile inferiore a causa del diametro del nucleo ridotto e Fibra 10 um Per l
246. ic Installation Instructions for BFOC Connectors Removing the Buffer To strip the buffer from the plastic fibers use the SIMATIC NET buffer stripper included in the stripping tool set Important note Use the opening labeled AWG 16 1 5 mm Smaller openings damage the fiber and must not be used Insert the cord into the opening labeled AWG 16 The cord must extend at least 10 mm beyond the blade Open the handles of the tool until the clamp releases the cord Remove the cord from the tool Only open the handles of the tool completely after you have removed the cord Caution If the handles are opened completely before the cord has been removed the fiber can be damaged by the blade as it is retracted Repeat the same procedure for the second cord Page 7 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors Crimping the BFOC Connector Push the black anti kink boot short Push the crimping sleeve onto the Press together the handles of the crimping sleeve body of the connector connector body as far as the end stop crimping tool to open it onto the stripped cords Caution The fiber must extend at least 1 mm beyond the face of the connector Insert the crimping sleeve into the front Press the handles of the crimping tool Open the crimping tool and remove the opening hexagonal 3 25 mm together firmly The connector body is cord Mak
247. icato su un lato su una mem brana di plastica e Appoggiare lo schermo direttamente nel punto di ingresso del cavo nell armadio su una guida di schermaggio Figura C 3 Fissaggio dei cavi schermati con fascette serracavi ed elemento di collega mento per tubi rappresentazione schematica Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 9 Installazione dei cavi di bus Togliendo la guaina dei cavi va fatta attenzione a non danneggiare lo schermo a maglia dei cavi Durante la scelta degli elementi di contatto necessario tenere in considera zione che lo schermo a maglia dei cavi per SIMATIC NET PROFIBUS ha un diametro esterno di ca 6 mm Per un buon contatto tra gli elementi di messa a terra sono adatte superfici sta gnate o stabilizzate galvanicamente In caso di superfici stagnate i contatti ne cessari devono essere protetti con un collegamento a vite adatto Vanno asso lutamente evitate superfici verniciate sui punti di contatto punti di collegamento contatto dello schermo non devono essere utilizzati come scarico di tiro Il contatto con la guida di schermaggio potrebbe peggio rare o strapparsi 2 2 2 3 dI A Figura C 4 Applicazione dello schermo sui punti di ingresso dell armadio C 4 4 Equipotenzialit Quando si verificano differenze di potenziale Le differenze di potenziale possono derivare p es da diverse alimentazioni della rete Le differenze di potenzi
248. icolo di esplosione Questo modello caratterizzzato dal fatto che al bus da campo collegato solo un appa recchio attivo l apparecchio di alimentazione del bus Gli altri apparecchi sono in base alla possibilit di alimentare la potenza sul cavo passivi Le propriet dei cavi non infuiscono entro determinati limiti sulla sicurezza intrinseca Reti PROFIBUS SIMATIC NET Glossar 2 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Glossario GSD dati base dei dispositivi GSD contengono descrizioni slave DP in un formato uniforme L utilizzo di GSD semplifica la progettazione del master e dello slave DP Guida profilata a norma Guida metallica a norma secondo EN 50 022 La guida profilata a nomra serve per il montaggio ad innesto rapido di compo nenti di rete come OLM repeater ecc Impedenza dello schermo Impedenza dello schermo del cavo Limpedenza dello schermo una grandezza caratteristica del cavo utilizzato e viene normalmente specificata dal costruttore Indirizzo PROFIBUS Per l identificazione univoca ogni stazione deve ricevere un indirizzo PROFI BUS PC PG o l ET 200 handheld hanno l indirizzo PROFIBUS 0 Master e slave hanno un indirizzo PROFIBUS compreso nel campo da 1 a 125 IP 20 Classe di protezione secondo DIN 40050 protezione contro il contatto con dita e contro la penetrazione di corpi estranei solidi con un diametro superiore a 12mm IP 65 Classe di protezione secondo DIN 40050 p
249. ienti con solleci tazione chimica e meccanica Esso concepito per l installazione fissa all interno di edifici cablaggio In house Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 1 5 PROFIBUS Flexible Cable cavo di bus resistente alla torsione Materiale di riempimento Guaina esterna di PUR filato di poliestere Foglio in materiale sintetico Schermo a maglia in rame e interno a trefoli in rame solamento in PE cellulato Tessuto Figura 4 5 Principio di struttura del cavo di bus resistente alla torsione cavo per robot Cavo di bus resistente alla torsione 6XV1 830 0FH10 Il cavo di bus resistente alla torsione 6XV1 830 0FH10 corrisponde alla maggiore resistenza del conduttore della specifica secondo EN 50170 tipo di cavo A con conduttori interni a trefoli in rame ca AWG24 19 36 Questo scostamento causa una lunghezza ridotta del segmento osservare la ta bella nel capitolo 3 Istruzioni di progettazione Rispetto al cavo di bus standard nel cavo di bus resistente alla torsione i condut tori sono realizzati con trefoli in rame In combinazione con la speciale composi zione di schermo a magia schermo a foglio di tessuto e dalla guaina esterna in poliuretano viene ottenuta una resistenza alla torsione di 180 e il mantenimento delle elevate propriet elettriche Il cavo stato sottoposto ad un testo con min 5 milioni di movimenti di tors
250. illustra il collegamento del DP PA Link Programming Operating and Monitoring SIMATIC PCS 7 oppure al tro strumento per la parame Livello di gestione Industrial Ethernet trizzazione Master DP S7 Gateway PDM oppure altro strumento S7 400 A um per la parametrizzazione Livello di cella PROFIBUS DP DP PA Link Accoppiatore DP PA 2 4 ET200X ll Livello di campo Apparecchiatura da campo di PROFIBUS PA Figura 2 16 Collegamento del DP PA Link DP PA Link deve essere montato al di vuori dell area soggetta a pericoli di esplo sione DP PA Link viene progettato con STEP 7 a partire dalla versione 4 02 Reti PROFIBUS SIMATIC NET 2 24 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Propriet DP PA Link presenta le seguenti caratteristiche Diagnostica tramite LED e programma utente Slave DP e master PA Pu essere comandato con tutte le velocit di trasmissione da 9 6 kbit s a 12 Mbit s Con un IM 157 possono essere comandati esclusivamente accoppiatori DP PA Tipo di funzionamento La figura 2 17 illustra il tipo di funzionamento del DP PA Link con l IM 157 e l ac coppiatore DP PA Il DP PA Link forma il sistema PROFIBUS PA subordinato su uno slave DP PROFIBUS DP completamente disaccoppiato da PROFIBUS PA tramite il DP PA Link master PA e gli slave PA formano un sistema di bus subordinato autonomo La moltip
251. in the event of a malfunction Refer to the manufacturer s manual of the terminal concerned for details about how to alter the settings 3 1 1 Line topology with optical fiber link monitoring and segmentation This operating mode should preferably be used if an interrupted fiber segment is to be separated from the rest of the network Only use this operating mode if you have just connected PROFIBUS OLMs together of the same version Monitoring mechanisms Send echo yes Monitor echo yes Suppress echo yes Monitor yes Segmentation yes In this operating mode the individual fiber links are monitored by the two connected modules If a module fails an optical fiber breaks or faults are determined on the optical transfer link the fiber link between the two OLMs is interrupted segmented The PROFIBUS network is divided into two partial networks which remain functional independently of one other The malfunction is indicated at the two OLMs connected to the malfunctioning fiber link by the port LEDs switching to red and by activation of the signaling contacts The segmentation is lifted automatically as soon as both modules recognize that the field bus network is functioning correctly with the help of test frames Please note that in the case of networks with several active bus subscribers two logical token rings are formed in the event of an error Every time the partial networks are switched together network malfunctions may arise due
252. ing for details see Chap 3 3 Redundant optical ring p 13 1 Configuration of a non existent bus subscriber 2 Increasing the retry value to at least 3 3 Checking and adjusting the slot time Use the user specific profile of the configuration tool to set the parameters under 2 and 3 Calculate the slot time with the following equation Slot time a b Length op c Number om Slot time is the monitoring period in bit times Length or is the sum of all the optical fiber lines segment lengths in the network The length must be given in km Number om is the number of PROFIBUS OLMs in the network The factors a b and c are dependent on the transmission rate and are listed in the tables below Version 1 1 8 00 29 Configuration 6 2 Configuration of redundant optical rings Data rate a b c 12 MBit s 1 1651 240 28 6 MBit s 1 951 120 24 3 MBit s 1 551 60 24 1 5 MBit s 351 30 24 500 kBit s 251 10 24 187 5 kBit s 171 3 75 24 93 75 kBit s 171 1 875 24 45 45 kBit s 851 0 909 24 19 2 kBit s 171 0 384 24 9 6 kBit s 171 0 192 24 Table 3a Constants for calculating the slot time at DP standard redundant optical ring Data rate a b Cc 12 MBit s 1 1651 240 28 6 MBit s 1 951 120 24 3 MBit s 1 551 60 24 1 5 MBit s 2011 30 24 500 kBit s 771 10 24 187 5 kBit s 771 3 75 24 93 75 kBit s 451 1 875 24 45 45 kBit s 851 0 909 24 19 2 kBit s 181 0 384 24 9 6 kBit s 171 0 192 24
253. ing rights created by patent grant or registration of a utility or design are reserved Copyright Siemens AG 1999 All Rights Reserved We would further point out that for reasons of clarity these operating instructions cannot deal with every possible problem arising from the use of this system Should you require further information or if any special problems arise which are not sufficiently dealt with in the operating instructions please contact your local Siemens representative The SpliTConnect Tap System described in this Mounting Instructions is intended only for use with PROFIBUS FC Process Cable Using the system for any other purpose can lead to injury or to damage of the SpliTConnect System or the cable Mounting of SpliTConnect System components only may be done with bus segments which are not in operation Personnel qualification requirements Qualified personnel as referred to in the operating instructions or in the warning notes are defined as persons who are familiar with the installation assembly startup and operation of this product and who possess the relevant qualifications for their work and have a First Aid qualification Copyright 1999 Siemens AG Montageanleitung f r SIMATIC NET PROFIBUS SpliTConnect System Mounting Instruction for SIMATIC NET PROFIBUS SpliTConnect System Montage Mounting SpliTConnect Tap Bestell Nummer Ord code 6GK1905 0AA00 A u 1 Kontak
254. inizio o alla fine della rete Avvertenza Limitazioni per il funzionamento del bus terminal 12M con 500 kbit s Questa limitazione riguarda solo segmenti con lunghezza superiore a 80 m Se il bus terminal 12M viene comandato con una velocit di trasmissione di 500 kbit s insieme al bus terminal RS 485 con cavo di derivazione di 3 0 m 6GK1 500 0AB00 necessario mantenere una distanza minima di 5 m tra i bus terminal RS 485 con cavo di derivazione lungo 3 0 m 5 m di cavo PROFI BUS bus terminal 12M possono essere disposti in un segmento in un ordine qualsiasi vale a dire che non necessario mantenere una distanza minima bus terminal 12M pu essere disposto anche tra due bus terminal RS 485 con cavo di derivazione lungo 3 0 m importante solo che il cavo PROFIBUS tra i due bus terminal RS 485 con cavo di derivazione lungo 3 0 m sia complessiva mente lungo almeno 5 m Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 7 4 Montaggio collegamento del cavo i di bus Il bus terminal pu essere montato meccanicamente in tre modi e mediante innesto a scatto su una guida ad U standard di 15 mm x 35 mm secondo DIN EN50022 35x15 e mediante collegamento a vite con una piastra di montaggio Il fissaggio viene eseguito rispettivamente con una vite a testa cilindrica Lo schema di foratura per il fissaggio a vite riportato nella figura 4 31 A Bordo super
255. io rispettare le distanze di sicurezza specificate nel capitolo C 5 1 del presente manuale Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Installazione dei cavi nel terreno Avvertenza Per un installazione diretta nel terreno adatto solo il cavo di posa interrata SIMATIC NET PROFIBUS In caso di installazione dei cavi di bus a contatto diretto con il terreno si consiglia quanto segue Installazione del cavo di bus in una fossa Profondit di installazione del cavo di bus ca 60 cm sotto la superficie del ter reno Ai cavi di bus necessario applicare una protezione meccanica e installare in sieme una banda di segnalazione di cavi ca 20 cm sopra i cavi di bus deve essere installata un equipotenzialita tra gli edifici da collegare p es presa di terra a nastro zincata La presa di terra a nastro costituisce contemporaneamente la protezione contro fulmini diretti Se i cavi di bus devono essere installati insieme ad altri cavi necessario ri spettare le distanze descritte nel capitolo C 5 1 p es impiegando mattoni come separatori La distanza dai cavi di corrente ad alta tensione deve essere gt 100 cm sempre che non esistano altre direttive che richiedono una distanza maggiore C 5 5 Provvedimenti speciali per l eliminazione di disturbi Collegamento dell induttivit commutata con dispositivi di spegnimento La commutazione di induttiv
256. ione di reti ottiche PROFIBUS vanno osservati i seguenti parametri e Coni cavi in fibra ottica possibile realizzare solo collegamenti punto a punto e L attenuazione massima del segnale della linea di trasmissione il budget di attenuazione deve trovarsi entro i valori ammessi e Le velocit di trasmissione minime o massime ammesse dei componenti in una rete possibile utilizzare un unica velocit di trasmissione e Le regole di collegamento in cascata per i componenti impiegati e Il numero massimo ammesso di nodi in una rete e In caso di reti estese il tempo di transito del telegramma Transmission Delay Time Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 11 Progettazione di reti 3 2 1 Tipo di funzionamento di un sistema di trasmissione con cavi in fibra ottica Introduzione Questo capitolo descrive la struttura e il tipo di funzionamento di un sistema di trasmissione ottico Esso fornisce informazioni per una migliore comprensione delle regole per il calcolo del bilancio ottico della potenzialit descritto nel capitolo successivo Linea di trasmissione Una linea di trasmissione ottica composta da trasmettitori fibre ottiche e ricevitori Alimentazione Alimentazione Fibra ottica Preparazione Conver del segnale titore E O E O Convertitore elettro ottico Segnale elettrico Segnale elettrico g O E Convertitore ottico elettrico digitale analogico digit
257. ione su una lunghezza del cavo di 1 m 180 Durante l allacciamento ai morsetti a vite i conduttori a trefoli devono essere avvi tati solo con l aiuto di capicorda 0 25 mm secondo DIN 46228 Il connettore di bus 6ES7 972 OBA30 0XA0 non pu essere allacciato Il cavo non adatto per l impiego del FastConnect FC Stripping Tool Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 11 Componenti passivi per reti RS 485 Propriet Impiego 4 12 Rispetto al cavo di bus standard il cavo di bus resistente alla torsione presenta le seguenti propriet e il materiale della guaina esterna esente da alogeni poliuretano PUR e un ottima resistenza allo sfregamento e resistenza a grassi e oli minerali e un ottima resistenza a radiazioni UV e piccoli raggi di curvatura per la posa e il funzionamento e la resistenza del conduttore e l attenuazione di alta frequenza sono maggiori a causa della sezione ridotta in rame comportando cos una riduzione della lun ghezza del segmento e il materiale della guaina esterna resistente alla fiamma Il cavo di bus resistente alla torsione progettato per una torsione di 180 e di conseguenza particolarmente adatto per il collegamento di parti di impianti in mo vimento come p es robot Avvertenza In caso di allacciamento con morsetti a vite i conduttori a trefoli devono essere avvitati solo con l aiuto di capicorda 0 25 mm secondo DI
258. iore bus terminal 50 mm N A Filettatura M4 o foro passante 4 2mm 67 3 mm y 50 mm Figura 4 31 Schema di foratura per bus terminal e con montaggio a parete murature calcestruzzo Sono necessari 2 tasselli del tipo 5 2 viti per legno a testa tonda DIN96 spessore 3 5 L70 e due rosette DIN 125 4 3 Per i fori valgono le specificazioni della figura 4 31 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 55 Componenti passivi per reti RS 485 Avvertenza Fare attenzione che la posizione di montaggio del bus terminal deve essere ac cessibile anche durante l esercizio per interventi di manutenzione e di montaggio Per l allacciamento del cavo di bus sono necessarie le seguenti operazioni vedere figura 4 32 1 Aprire il cavo di bus sul punto in cui deve essere inserito il bus terminal 2 Tagliare la guaina esterna ad una lunghezza di ca 33 mm facendo attenzione a non danneggiare lo schermo a maglia 3 Accorciare lo schermo a maglia e lo schermo a foglio a ca 12 mm lo schermo a foglio pu anche sporgere leggermente Schermo a foglio Risvoltare lo schermo a maglia sulla guaina del cavo Figura 4 32 Preparazione del cavo i di bus per l allacciamento al bus terminal 4 Risvoltare di nuovo lo schermo a maglia sulla guaina del cavo 5 Togliere la protezione di solamento dall estremita dei conduttori di ca 10 mm 6 Fissare il cavo di bus al terminal in mo
259. isegni in scala del repeater RS 485 45 73 128 T_T 125 Figura F 7 Repeater RS 485 su guida profilata a norma 45 70 125 a EE SI I Figura F 8 Repeater RS 485 su guida profilata per S7 300 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 F 5 DISEGNI IN SCALA F 3 70 Figura F 9 F 6 Disegno in scala del PROFIBUS terminator SIEMENS PROFIBUS TERMINATOR DC 24 V L M PE Ai BI OOO OO ARB AR pe HOloIcH 6ES7 972 0DA00 0AA0 X 2 3 4 5 PROFIBUS terminator Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA F 4 Disegno in scala del bus terminal RS 485 m 53 T gt A SIEMENS SINEC L2 PG oP i t Bus terminal RS 485 O 138 099999 8 lt 1 90 Figura F 10 Bus terminal RS 485 su guida profilata a norma con altezza di 15 mm Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 DISEGNI IN SCALA
260. isolamento del cavo di bus PROFIBUS in base alla figura 5 10 La maglia di schermatura deve essere risvoltata sul cavo Solo in questo modo la fascetta di schermatura pu successivamente servire come scarico di tiro e come elemento di schermatura p es Standard Cable p es Underground Cable 6XV1 830 0EH10 6XV1 830 3FH10 8 5 16 10 16 16 10 Lalli el Lai mai SIEMENS SIEMENS m f La maglia di schermatura deve essere risvoltata 8 5 Figura 5 10 Lunghezza sulla quale togliere l isolamento per l allacciamento al PROFIBUS Terminator 3 Allacciare il cavo di bus PROFIBUS al PROFIBUS Terminator Allacciare i conduttori uguali verde rosso per cavo di bus PROFIBUS allo stesso allacciamento A o B collegare p es l allacciamento A sempre al filo verde e l allacciamento B sempre al filo rosso 4 Avvitare la fascetta di schermatura in modo che lo schermo appoggi diretta mente sulla fascetta di schermatura Avvertenza Durante il montaggio necessario fare attenzione che per i connettori di bus non sia attivata nessuna resistenza terminale se il PROFIBUS montato con 2 PRO FIBUS Teminatoren attivi Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per PROFIBUS PA Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 6 6 1 Componenti pa
261. isponibile solo preconfezionato cavi per apparecchi con interfac cia ottica integrata sono muniti di 2x2 connettori simplex mentre i cavi per il colle gamento di OLM P11 e OLM P12 sono muniti di 2x2 connettori BFOC Essi ven gono forniti con un elemento ausiliario di inserimento montato su un lato che permette p es l inserimento in canali di cavi Reti PROFIBUS SIMATIC NET 7 10 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Propriet Impiego 75m 100m 150m 200 m 250 m 300 m 400 m Il cavo standard in fibra ottica di PCF progettato per carico di tiro continuativo di 100 N resistente con limitazioni all olio minerale ASTM N 2 resistente con limitazione al grasso minerale resistente con limitazioni all acqua resistente con limitazioni a radiazioni UV resistente alla fiamma in base al test VW 1 secondo UL 1581 Il cavo standard in fibra ottica di PCF 6XV1821 1B un cavo rotondo resi stente per l impiego all interno di edifici con cavo lungo fino a 400 m OLM o 300 m interfacce ottiche integrate OBT rispettivamente tra 2 nodi Dati per l ordinazione cavi PCF Fiber Optic confezionati per OLM P SIMATIC NET PROFIBUS PCF Fiber Optic I VY2K 200 230 10A17 8B20 fibra ottica PCF con 2 conduttori guaina esterna in PVC per realizzare grandi distanze fino a 400 m confezionato con 2x2 connettori BFOC lunghezza dei conduttori che sporgono dalla guaina
262. it p es rel genera tensioni di disturbo la cui al tezza rappresenta un multiplo della tensione d esercizio inserita Nei manuali di sistema ET 200 9 decentrati si trovano proposte per limitare le tensioni di di sturbo di induttivit collegando dispositivi di spegnimento Allacciamento alla rete per dispositivi di programmazione Si consiglia di prevedere in ogni armadio di comando una presa per l alimentazione di dispositivi di programmazione La presa deve essere alimentata dalla distribu zione alla quale allacciato anche il conduttore di protezione per l armadio Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Illuminazione dell armadio Per l illuminazione dell armadio utilizzare una lampada p es LINESTRA Evitare l uso di lampade fluorescenti in quanto questo tipo di lampade genera campi di disturbo Se inevitabile l impiego di lampade fluorescenti necessario adottare le misure illustrate nella figura C 5 Griglia di schermaggio sulla lampada Cavo schermato i Interruttore con capsula di prote zione metallica Filtro di rete o cavo di alimenta zione della rete schermato Figura C 5 Misure per l eliminazione di disturbi provocati da lampade fluorescenti nell armadio Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 19 Inst
263. it s and 5 s at 9 6 KBit s If the transmission speed has not been recognized the outputs of all ports are blocked If the transmission rate changes during operation this is detected by the modules which then automatically adjust their settings accordingly Transfer malfunctions may temporarily occur while the rate is being altered Signal regeneration The modules regenerate the signal form and amplitude of the data received This allows up to 122 PROFIBUS OLMs to be cascaded limited by the address space in PROFIBUS networks Help when setting up At least one bus subscriber must be switched on and active in order to check the optical fiber connections during the installation This bus subscriber serves as the frame source The PROFIBUS OLMs act passively when it is switched on They recognize the transfer speed from the frames sent by the bus subscriber An optical help when putting the device into operation is provided by the port LED which then lights up 2 2 Operating mode related functions The operating mode is set using switches located on the top of the module A sticker attached to the side of the module provides assistance with the settings Segment monitoring at the RS 485 port If the operating mode Electric port with segment monitoring is set each receiver monitors the RS 485 bus segment connected to it for faulty frames or continuously busy networks If faulty frames are received by the receiver or if the network is
264. it times from RS 485 input to infrared output when sending and 3 bit times from infrared input to RS 485 output when receiving The total delay time of the RS 485 input of the sending PROFIBUS ILM to the RS 485 output of the receiving PROFIBUS ILM is therefore 9 bit times If several PROFIBUS ILM links are cascaded the total delay time is the product of 9 bit times of the individual links and the cascading depth 10 2 3 Delay Time of Further Active PROFIBUS Network Components Please refer to the delay time listed in the documentation of the specific product 10 2 4 Transmission Delay Time TTD The total delay time of the PROFIBUS network is the sum of all the values calculated in Sections 10 2 1 to 10 2 3 45 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 11 Technical Specifications perating voltage Safety extra low voltage SELV Current consumption max 300 mA Transmission rate 9 600 Kbps 19 200 Kbps 45 45 Kbps 93 75 Kbps 187 5 Kbps 500 Kbps 1 5 Mbps Setting the transmission rate Using 3 DIP switches Setting the mode Using 5 DIP switches Bit error rate Signal delay time lt 6 bit times RS 485 input infrared output Signal delay time lt 3 bit times infrared input gt RS 485 output Electrical channel Input output signal RS 485 level Input voltage dielectric strength 10 Vto 15V Interface signals Ungrounded within the SELV limits Terminating resistors Activated with D
265. itta verso il basso sul lato inferiore del repeater RS 485 utilizzando un cacciavite 2 Sfilare il repeater RS 485 dalla guida profilata spostandolo verso l alto Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 5 11 Componenti attivi per reti RS485 5 4 Funzionamento del repeater RS 485 senza collegamento a terra Funzionamento senza collegamento a terra Funzionamento senza collegamento a terra significa che massa e PE non sono collegati Con il funzionamento del repeater RS 485 senza collegamento a terra possibile utilizzare i segmenti di bus con separazione di potenziale La figura 5 8 illustra la differenza dei rapporti di potenziale impiegando il repeater RS 485 Segnale senza fil collegamento a terra efe Segnale con collega ni a mento a terra Figura 5 8 Funzionamento dei segmenti di bus senza collegamento a terra Reti PROFIBUS SIMATIC NET 5 12 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 5 5 Allacciamento della tensione di alimentazione Tipo di cavo Per l allacciamento del cavo di alimentazione DC 24 V utilizzare cavi flessibili con una sezione da 0 25 mm a 2 5 mm AWG da 26 a 14 Allacciamento dell alimentazione Per allacciare l alimentazione del repeater RS 485 procedere nel modo seguente 1 Togliere l isolamento del cavo per la tensione di alimentazione DC 24 V 2 Allacciare il cavo ai m
266. itungsabg nge durchf hren dabei jeweils Kodierung K beachten Repeat assembling steps 2 to 6 for the remaining cable ports and pay attention to the codings K by doing so 8 Kontaktierelement 2 in SpliTConnect Tap 1 ein 9 Kontaktierelement 2 bis auf Anschlag anziehen f hren Ausrichtung ist durch Nut N und F hrung Zur Unterst tzung kann ein Schraubendreher durch im Kontaktierelement 2 vorgegeben die daf r vorgesehene ffnung im Kontaktier Achtung Alle 3 Abg nge m ssen korrekt best ckt element 2 gesteckt werden sein Tighten contacting element 2 as much as possible Insert contacting element 2 into SpliTConnect Tap For supporting this a screw driver can be used 1 Alignment is given by groove N and slot in the by inserting in the provided hole of the contacting contacting element 2 element 2 Attention All 3 ports have to be mountet correctly Erdung Bei Bedarf kann das SpliTConnect Tap geerdet werden Hierzu steht am Kontakierelement 2 ein M4 Gewinde zur Verf gung Es wird empfohlen einen Kabelschuh zu verwenden Grounding If neccessary the SpliTConnect Tap can be grounded For this purpose a M4 thread at the contacting element 2 is available It is recommended to use a thimble Copyright 1999 Siemens AG Montageanleitung f r SIMATIC NET PROFIBUS SpliTConnect System Mounting Instruction for SIMATIC NET PROFIBUS SpliTConnect System Montage nicht benutzter A
267. izione 2 05 2000 Componenti passivi per reti RS 485 Dati tecnici La seguente tabella riporta i dati tecnici dei diversi connettori di bus Tabella 4 4 Dati tecnici dei connettori di bus in IP 20 Numero di ordinazione 6ES7 972 OBA50 0XA0 OBB50 0XA0 6GK1 500 OFCOO Connettore femmina PG OBA50 no no OBB50 si Velocit massima di trasmissione 9 6 kbit s 12 Mbit s 9 6 kbit s 12 Mbit s Uscita cavo 90 180 Resistenza terminale Combinazione di resistenza inte grata e attivabile tramite interrut tore a scorrimento Funzione di scollegamento Con la resistenza attivata viene scollegato il bus in partenza Al lacciamento con tecnica a perfo razione d isolante per sistema FastConnect Combinazione di resistenza inte grata e attivabile tramite interrut tore a scorrimento Funzione di scollegamento Con la resistenza attivata viene scollegato il bus in partenza Al lacciamento con tecnica a perfo razione d isolante per sistema FastConnect Interfacce verso nodo PROFIBUS verso cavo di bus PROFIBUS Connettore Sub D a 9 poli 4 morsetti di perforazione per tutti i cavi FastConnect PROFI BUS eccetto FC Process Cable Connettore Sub D a 9 poli 4 morsetti di perforazione per tutti i cavi FastConnect PROFIBUS eccetto FC Process Cable Tensione di alimentazione deve provenire dal terminale di dati DC 4 75 fino a 5 25 V DC 4 75 fino a 5 25
268. l Link Module con 1 interfaccia RS485 e 2 interfacce per fibra ottica di plastica con con tatto di segnalazione e uscita di misura PROFIBUS OLM G11 6GK1 502 2CB00 Optical Link Module con 1 interfaccia RS485 e 1 interfaccia per fibra ottica di vetro per di stanze standard con contatto di segnalazione e uscita di misura PROFIBUS OLM G12 6GK1 502 3CB00 Optical Link Module con 1 interfaccia RS485 e 2 interfacce per fibra ottica di vetro per di stanze standard con contatto di segnalazione e uscita di misura PROFIBUS OLM G11 1300 6GK1 502 2CC00 Optical Link Module con 1 interfaccia RS485 e 1 interfaccia per fibra ottica di vetro per grandi distanze con contatto di segnalazione e uscita di misura PROFIBUS OLM G12 1300 6GK1 502 3CC00 Optical Link Module con 1 interfaccia RS485 e 2 interfacce per fibra ottica di vetro per grandi distanze con contatto di segnalazione e uscita di misura Istruzioni per l uso Le istruzioni per l uso complete del Optical Link Module OLM si trovano nell appen dice del presente manuale Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 8 7 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti senza fili Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 9 1 Componenti attivi per reti senza fili 9 1 Infrared Link Module ILM Cha PROFIBUS LM Settore d impiego
269. l cavo di connessione PG cavo di connessione SIMATIC S5 S7 12 Mbaud deve essere sommato al fattore capacitivo del relativo elemento di allacciamento 3 3 Se la distanza minima inferiore del valore descritto al punto 3 2 si provvede alla cosiddetta formazione di gruppi ed necessario osservare le seguenti condizioni supplementari Gli elementi di allacciamento possono essere assegnati a piacere uno di fianco all altro se la somma dei loro fattori capacitivi non supera il valore 5 La distanza in metri tra due gruppi adiacenti deve essere almeno uguale alla somma dei fattori capacitivi di entrambi i gruppi Reti PROFIBUS SIMATIC NET 3 6 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Tabella 3 5 Esempi di applicazione per le regole di progettazione Senza condizioni generali particolari se il cavo di bus tra due terminali di dati gt 10 m Senza condizioni generali particolari se i cavi di bus tra due terminali di dati sono maggiori della somma dei fattori capacitivi di entrambi i terminali di dati Se un bus terminal o un connettore di bus con tiene un interfaccia PG durante il calcolo dei valori capacitivi necessario considerare un cavo di con nessione PG allacciato Tener conto della somma dei fattori capacitivi nel gruppo se la somma dei fattori capacitivi super iore del cavo di bus tra i terminali di dati Successivamente gli elementi possono trovarsi ad una distanza qualsiasi
270. la guida di metallo Collegamento del cavo di bus per tutte le altre stazioni sul bus Interruttore OFF lt resistenza termi nale disattivata Lo schermo del cavo deve appoggiare completamente sulla guida di metallo 1 Il cavo di bus deve sempre essere collegato a sinistra Figura 4 23 Collegamento del cavo di bus al connettore di bus 6ES7 972 0B 40 6 Avvitare il contenitore Avvertenza conduttori a trefoli possono essere avvitati solo con l aiuto di capicorda 0 25 mm secondo DIN 46228 Utilizzare solo copicorda di materiale con propriet di contatto a stabilit permanente p es rame con superficie stagnata non alluminio Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 43 Componenti passivi per reti RS 485 4 5 Montaggio del connettore di bus con uscita assiale del cavo Aspetto 6GK1500 0EA02 SI DFF _ ON 5 Collegamento del cavo di bus e posizione dell interruttore per la prima e l ultima stazione su
271. le is not twisted Loops and torsion under tensile load can cause kinks or cracks that may mean irreparable damage to the cable Follow the instructions in this manual and use the tools described here Set the cutting depth of the cable knife part of the stripping tool set order no 6GK1 905 6PA10 to a depth of 1 5 mm prior to use The cutting depth is set with the adjusting screw at the end of the handle Turning the adjusting screw clockwise increases the cutting depth Turning the adjusting screw counter clockwise reduces the cutting depth Make sure that the outer jacket and buffers of the cable and the plastic fibers are not damaged When stripping the buffer from the fiber use only the opening in the stripper marked AWG 16 Nicks or scratches can allow light to escape and can therefore lead to increased attenuation values and failure of the transmission path With time such defects can also lead to breaks in the fiber and to failure of the network When grinding and polishing make sure that there is only slight pressure from the connector onto the paper to avoid fusion of the metal parts and fiber plastic Make sure that you keep to the bending radii when grinding and polishing particularly when the cables are supported to provide mechanical strain relief In this case make sure that you strip an adequate length of the outer jacket Never insert contaminated connectors or connectors with fibers extending beyond the end face into
272. levant qualifications for their work and have a First Aid qualification Page 2 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors General Instructions for Working with SIMATIC NET PROFIBUS Plastic Fiber Optic Cables Please note the following instructions to avoid damage to cables E Make sure that the selected cable is suitable for the area of application You should for example check the following Required temperature range Resistance of the jacket materials to chemicals water oils rodents etc to which the cable may be exposed in your application Required mechanical properties bending radii tensile strength transverse compressive strength Required behavior of the cable in fire Suitability of the cable including the connectors for the devices to be interconnected If necessary use a special cable that meets your requirements Your SIMATIC NET contact in your local Siemens branch will be happy to advise you Never exceed the maximum permitted loads tensile load transverse compressive load etc specified in the data sheet of the cable you are using Excessive transverse compressive load can for example result from using screw clamps to secure the cable Only use plastic fiber optic cables with devices approved for this plastic FO cable Keep to the maximum permitted cable lengths When cutting cables to length make sure that no loops are formed and that the cab
273. lex Il canale ottico colle gato all OLM12M con un OBT deve essere comandato nel modo oprativo Line con il controllo del percorso disinserito Monitor off ET200M senza Nodo DP senza SIMATIC S7 400 ET200M senza ottica integrata ottica integrata con IM 467 ottica integrata fl gt N I feste cs alli a Hun p i IRINA i la O LI o LI 2 2 1 1 ET200M senza ottica integrata OBT OBT OBT 3 5 4 Um a E ami i si Eg Ae fre 4 4 Resistenza terminale attivata 1 Cavo PROFIBUS con terminazione su entrambi i lati 2 Cavo PROFIBUS 3 Percorso PROFIBUS senza terminazione 4 Cavo a due fibre ottiche di plastica o PCF Figura 4 2 Esempio per il collegamento di segmenti RS485 PROFIBUS Optical Busterminal OBT 4 3 C79000 G8972 C1 22 02 PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Messa in funzione 5 Avvertenza Utilizzare PROFIBUS OBT esclusivamente come previsto nelle presenti istruzioni per l uso Avvertenza Osservare in particolare tutti gli avvertimenti e le avvertenze rilevanti per la sicu rezza Avvertenza Utilizzare PROFIBUS OBT solo con una tensione di sicurezza a basso voltaggio secondo IEC 950 EN 60 950 VDE 0805 di max 32 V tipo 24 V La fonte di tensione deve corrispondere alle prescrizioni di NEC classe 2 in base all autoriz zazione UL CSA Avvertenza Non guardare direttamente nell apertura dei diodi di t
274. licazione dell accoppiatore DP PA serve solo ad aumentare il rendi mento di corrente Tutti gli accoppiatori DP PA con le apparecchiature da campo PA allacciate formano un unico sistema di bus PROFIBUS PA DP PA Link Slave DP Master PA Bus backplane S7 Accoppiatore DP PA max 5 Figura 2 17 Tipo di funzionamento del DP PA Link con accoppiatori DP PA Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 25 Topologie delle reti SIMATIC NET PROFIBUS Regole Per la realizzazione di PROFIBUS PA valgono le seguenti regole e in un sistema PROFIBUS PA devono esserci al massimo 31 apparecchiature da campo PA e in un segmento PROFIBUS PA fisico pu essere allacciato solo un alimentatore accoppiatore DP PA e ad un DP PA Link possono essere allacciate al massimo 31 apparecchiature da campo PA Il numero massimo di apparecchiature da campo PA allacciabili per ogni segmento PROFIBUS PA fisico o per ogni accoppiatore DP PA limi tato dalla corrente massima di uscita dell accoppiatore e dai dati I O da trasmet tere Reti PROFIBUS SIMATIC NET 2 26 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS 2 5 5 Passaggio da PROFIBUS DP a RS 232C Struttura SIEMENS W Device WB interface U Figura 2 18 DP RS 232C Link per PROFIBUS DP Il DP RS 232C Link composto da un cont
275. linea tra due OLM pu es sere realizzata anche una struttura in base alla figura 2 6 Resistenza terminale attivata 1 cavo in fibra ottica 3 Cavo di connessione PROFIBUS 830 1T 2 cavo di bus PROFIBUS 4 Cavo di connessione PROFIBUS 830 2 Figura 2 6 Tecnica alternativa di cablaggio di una struttura della rete con topologia ottica ad anello a due fibre Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 11 Topologie delle reti SIMATIC NET PROFIBUS 2 2 3 Combinazione di interfacce ottiche integrate e OLM Avvertenza Le interfacce ottiche degli OLM sono ottimizzate per elevati raggi di azione L ac coppiamento diretto delle interfacce ottiche di un OLM con un OBT o interfacce ottiche integrate non ammesso a causa dei dati tecnici differenti Collegamenti di cavi in fibra ottica di vetro a linee delle interfacce ottiche integrate Figura 2 7 2 12 La lunghezza d onda di funzionamento delle interfacce ottiche integrate e dell OBT ottimizzata per l impiego di fibre di plastica o di PCF L allacciamento diretto di cavi in fibra ottica di vetro non possibile Se necessaria una linea di cavi in fibra ottica di vetro p es per realizzare di stanze superiori a 300 m questa linea deve essere eseguita c
276. lity to devices of the preceding generation SINEC L2FO OLM P3 P4 S3 S4 S3 1300 and S4 1300 either off or on Default setting at S7 is Position 0 compatibility is switched off 0 1 s7 E DIL switch S7 compatibility in Position 0 compatibility to SINEC L2FO OLM P3 P4 S3 S4 S3 1300 S4 1300 switched off s7 CH DIL switch S7 compatibility in Position 1 compatibility to SINEC L2FO OLM P3 P4 S3 S4 S3 1300 S4 1300 switched on The functional compatibility to SINEC L2 Optical Link Modules of the preceding generation SINEC L2FO OLM P3 OLM P4 OLM S3 OLM S4 OLM S3 1300 and OLM S4 1300 is switched on with the DIL switch S7 1 This operating mode is required when operating this module together with new devices Only turn switch S7 to Position 1 if the PROFIBUS OLM is being used as a spare or expansion device in existing networks in conjunction with OLMs of the preceding generation and a direct optical connection is to be made The following illustrations show the switch assignment of the OLM at S7 1 for OLM P3 und OLM P4 OLM S3 OLM S4 OLM S3 1300 und OLM S4 1300 Further information about adjusting the S7 in Position 1 SIEMENS SINEC L2FO OLM P3 OLM P4 S7 1 Compatibility Mode ON SIEMENS SINEC L2FO OLM S3 OLM S4 OLM S3 1300 OLM S4 1300
277. lle custodie della maggior parte dei componenti di rete SIMATIC NET sono appli cate delle aperture di ventilazione Per il raffreddamento efficace dell elettronica di esercizio ivi contenuta attraverso la custodia pu circolare l aria ambientale Le temperatura massime d esercizio riportate nei dati tecnici valgono solo per flusso d aria invariato attraverso le aperture di ventilazione A seconda delle dimensioni delle aperture di ventilazione le unit di questo tipo corrispondono al grado di protezione IP 20 IP 30 fino a IP 40 Il grado di prote zione esatto di un componente SIMATIC NET riportato nelle relative istruzioni per l uso componenti con il grado di protezione sopraindicato non offrono una protezione contro polvere e aqua Se il luogo d installazione richiede una protezione di questo tipo necessario montare i componenti in una custodia supplementare p es ar madio di comando con un grado di protezione superiore p es IP 65 IP 67 Per il montaggio in una custodia supplementare fare attenzione a rispettare le con dizioni d esercizio dei componenti Riscaldamento Fare attenzione che la temperatura all interno di una custodia supplementare non superi la temperatura ambiente ammessa dei componenti montati Scegliere una custodia in base alla grandezza oppure impiegare uno scambiatore di calore Installazione all aperto Distanze In caso di installazione all aperto evitare raggi di sole diretti sulla
278. llegamento del cavo ai componenti della rete A volte necessario il collegamento di due segmenti di cavi di bus p es per poter eseguire un passaggio dal cavo di bus standard ad un segmento con cavi a fe stoni Questo passaggio viene pi facilmente eseguito sui due allacciamenti del cavo di bus di un connettore di bus bus termonal o repeater L allacciamento dei cavi descritto in modo dettagliato nel presente capitolo 4 Le istruzioni per la posa e la protezione meccanica dei cavi sono riportate nell appendice C Posa dei cavi di bus Il passaggio da cavo per la posa interrata a cavo di bus standard consigliato per la protezione generale contro sovratensioni vedere appendice B Protezione con tro fulmini e sovratensioni Collegamento del cavo senza elementi di allacciamento del bus A volte necessario il collegamento di segmenti di cavi di bus in posizioni nelle quali non sono previsti allacciamenti di nodi o di componenti di reti p es per ripa razioni di un cavo di bus spezzato In questa caso osservare le seguenti avver tenze E necessario mantenere lo schermo su tutto il perimetro del cavo di bus Per il collegamento del cavo impiegare p es un connettore Sub D o un connet tore femmina convenzionale con contenitore metallico Un collegamento sicuro dello schermo viene garantito solo con componenti Sub D con collare dello schermo sagomato Evitare contatti casuali dello schermo con la zona circos
279. lly to the redundant power supply Load distribution between the individual alter native supply sources does not take place The signaling contact does not signal the failure of a single 24 V infeed Both of the infeeds and the signa ling contact must be connected to an input module for monitoring to take place Clips on the terminal block ensure that it is securely attached to the device and simultaneously provide polarity reversal protection 4 4 5 Connecting the signaling contact lines F1 F2 Fig 11 Signaling contact relay with unconnected contacts the contact is open if a fault occurs Version 1 1 8 00 The terminal block can be removed from the device to connect the lines A relay with unconnected contacts as signaling contacts is fitted to the 5 pin terminal block on the top of the module This signals faults and interference in the network and modules The contact is open if a fault occurs This also signals a total loss of power at the module Refer to Chapter 5 1 LED indicators p 25 for more details about malfunctions which are signaled by the signaling contact Signaling contact limit values maximum switching voltage 60 V DC 42 V AC maximum switching current 1 0 A The voltage connected to the relay must be regulated safety extra low voltage in accordance with IEC 950 EN 60 950 VDE 0805 and must comply with the regulations of the NEC Class 2 in accordance with UL CSA approval
280. lonna 2 e cavi per 3 Leggere nella colonna 3 installazione le direttive di installazione da rispet tare Reti PROFIBUS SIMATIC NET C 14 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Tabella C 1 Installazione dei cavi all interno di edifici Cavi per Segnali di bus schermato PROFIBUS Industrial Ethernet Segnali di bus senza schermo AS Interface e cavi per Segnali di bus schermato PROFIBUS Industrial Ethernet Segnali di bus senza schermo AS Interface Segnali di dati schermato PG OP stampante ingressi di conteggio ecc Segnali analogici schermato Tensione continua lt 60 V senza schermo Segnali di processo lt 25 V schermato Tensione alternata lt 25 V senza schermo Monitor cavo coassiale installazione in fasci o canali per cavi comuni Tensione continua gt 60Ves 400 V senza schermo Tensione alternata gt 25Ves 400 V senza schermo Tensione continua e alternata gt 400 V senza schermo in fasci o canali per cavi separati non necessaria una distanza minima all interno di armadi in fasci o canali per cavi separati non necessaria una distanza minima fuori da armadi su tracciati di cavi separati con distanza minima di 10 cm Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 15 Installazione dei cavi di bus C 5 2 Installazione
281. lung di trasmissione cavi di derivazione per hezza del cavo di derivazione ogni segmento di 15mo1 6m 3m 9 6 93 75 kbit s 96 m 32 32 187 5 kbit s 75m 32 25 500 kbit s 30m 20 10 3 1 2 Segmenti per velocit di trasmissione 1 5 Mbit s Velocit di trasmissione 1 5 Mbit s Il cavo SIMATIC NET PROFIBUS permette di realizzare le seguenti lunghezze massime di segmento Tabella 3 3 Lunghezze di segmento realizzabili Lunghezza di segmento per il tipo di cavo t di lt a FC Standard Cable FC Trailingcable Velocit di trasmiS _ EC Robust Cable PROFIBUS Flexible Cable FC FRNC Cable PROFIBUS Festoon Cable FC Food Cable FC Undergroundcable Cavo marino SIENOPYR FR Allacciamenti dei nodi con 1 5 Mbit s Ogni allacciamento di un nodo al cavo di bus rappresenta un adattamento anomalo capacitivo che non ha comunque effetto a basse velocit di trasmissione Ad una velocit di trasmissione di 1 5 Mbit s possono verificarsi disturbi dovuti all adatta mento anomalo se non vengono osservate le seguenti direttive relative al tipo al numero e alla ripartizione degli allacciamenti dei nodi Reti PROFIBUS SIMATIC NET 3 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Fattori capacitivi Per poter descrivere le configurazioni ammesse i singoli componenti di allaccia mento devono essere valutati in base al proprio carico capacitivo di bus A tale scopo vengono assegnati i cosiddetti fatt
282. luso PROFIBUS OBT e Connettore cavo a fibre ottiche PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 2 1 PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Descrizione del funzionamento 3 1 3 2 L OBT un repeater con 3 canali Interfacce Per l allacciamento di segmenti PROFIBUS DP l OBT dispone delle seguenti inter facce e Canale 1 CH1 un interfaccia elettrica RS485 Essa concepita come con nettore femmina SUB D a 9 poli Questo canale permette di allacciare un sin golo nodo PROFIBUS DP o un PC PGo OP all OB La lunghezza di segmento massima ammessa di 100 m Il segmento di rame deve essere mantenuto il pi corto possibile in quanto tramite questo segmento potrebbero essere con dotti disturbi nel PROFIBUS DP ottico e Il canale 2 CH2 e il canale 3 CH3 sono interfacce ottiche Entrambe sono concepite come connettori femmina duplex A ciascuno di questi connettori femmina duplex viene allacciata l estremit di un cavo a due fibre ottiche di pla stica o PCF confezionata con due connettori simplex L OBT dispone inoltre di un morsetto a due poli per l allacciamento dell alimenta zione di 24 V e in caso di necessit di un cavo di terra Conversione del segnale elettro ottico e rigenerazione del segnale L OBT converte il livello RS485 ricevuto sul canale 1 in livello di segnale ottico che viene emesso sui canali 2 e 3 segnali ricevuti sui canali 2 e 3 veng
283. ly an ungrounded high resistance voltmeter may be used to take measurements The reference potential socket may not be connected to the OLM housing Version 1 1 8 00 5 LED Indicators and Troubleshooting 5 1 LED Indicators 5 LED Indicators and Troubleshooting 5 1 LED Indicators LED indicators sim OO CH2 CH3 Receive Signal Intensity GND CH1 CH2 CH3 Fig 14 LED indicators on the front plate LED Indicator System lights green not lit flashes red flashes red green Version 1 1 8 00 Possible causes The transmission rate has been recognized and the power supply is in order Power supply has failed total failure Power supply connected incorrectly Module defective Transmission rate has not yet been recognized No transmitting bus subscriber present No connection to a partner module sending frames Send and receive optical fibers have been transposed Transmission rate does not correspond to the PROFIBUS standard Only one active bus subscriber is connected which is only sending tokens to itself The indicator must switch over after a second bus subscriber has been activated token frames on their own are not enough to set the transfer rate The connected RS 485 segment is only terminated at one end Transmission rate recognized but the network slot time could not be determined netw
284. m con 80 di modulazione di ampliezza a 1kHz 10kHz 80MHz ENV 50141 Resistenza contro disturbi condotti dal cavo su cavi dell alimentazione e su cavi di bus schermati RS 485 2 kV Burst IEC 61000 4 4 Resistenza contro disturbi condotti dal cavo sui cavi di alimentazione 1 kV simmetrico punte di tensione sovratensione su cavi di bus schermati RS 485 2 kV asimmetrico IEC 61000 4 5 Sicurezza Disposizione VDE VDE 0806 EN60950 e IEC950 Autorizzazione UL CSA in base a UL1950 CSA950 Condizioni ambientali climatiche Temperatura ambiente da 0 C a 60 C IEC 68 2 1 IEC 68 2 2 PROFIBUS Optical 7 2 Busterminal OBT C79000 G8972 C122 02 Dati tecnici Temperatura di magazzinaggio da 40 C a 70 C IEC 68 2 14 Umidit relativa lt 95 non condensante IEC 68 2 30 Condizioni ambientali meccaniche Oscillazioni funzionamento da 10 a 58 Hz inflessione 0 075mm da 58 a 150 Hz accelerazione 10m s 19 IEC 68 2 6 Oscillazioni trasporto da 5 a 9 Hz inflessione 3 5mm da 9 a 500 Hz accelerazione 10m s 1g Classe di protezione per protezione esterna con IP 30 lt 8A Peso 400 g Dimensioni 50 5 x 138 x 78mm Materiale scatola Noryl antracite PROFIBUS Optical Busterminal OBT 7 3 C79000 G8972 C1 22 02 PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Avvertenze relative al marchio CE 8 Denominazione del prodotto Optical Bus Terminal PROFIBUS OBT
285. me importante collegamento dell impianto Nei sistemi di automazione i cavi di bus rappresentano i collegamenti pi importati tra i singoli componenti dell impianto Un danneggiamento meccanico interruzione o un accoppiamento permanente di disturbi elettrici in questi collegamenti di bus riducono la capacit di trasmissione del sistema di bus In casi estremi questo pu comportare disturbi di funzionamento dell intero impianto di automazione se guenti capitoli illustrano come proteggere i cavi di bus da danni meccanici ed elet trici Osservanza del concetto di impianto I cavi di bus collegano sistemi di automazione che a loro volta sono collegati con cavi con convertitori di segnali alimentazioni apparecchiature periferiche ecc L in sieme di tutti i componenti costituisce un impianto di automazione elettrica colle gato in rete Per il collegamento di componenti dell impianto con cavi elettrici in questo caso cavi di bus fare attenzione a rispettare le esigenze specifiche di configurazione del sistema I cavi di collegamento influenzano in particolare i concetti e perla separazione sicura di tensioni di rete con pericolo di contatto e perla protezione dell impianto da sovratensioni p es protezione antifulmini e per la diffusione e la ricezione di disturbi e perla separazione di potenziale Collegamento in rete di SIMATIC con SIMATIC NET componenti di rete SIMATIC NET e i componenti di automazione SIMATIC son
286. meno 3 dB con una lunghezza d onda di 860 nm o di almeno 2 dB con una lunghezza d onda di 1300 nm Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 15 Progettazione di reti Punti di sdoppiamento Riserve di Foglio 3 16 In caso di punto di sdoppiamento necessario calcolare anche eventuali sdoppiamenti per i lavori di riparazione A seconda dell installazione dei cavi e dei possibili danni meccanici consigliabile calcolare uno o pi punti di riparazione ca 1 ogni 500 m Per ogni punto di riparazione sono sempre necessari due sdoppiamenti in quanto in un punto di riparazione necessario inserire uno spezzone di cavo pi o meno lungo a seconda della precisione dell apparecchiatura per la localizzazione dei guasti sistema Durante il calcolo della linea di trasmissione necessario rispettare una riserva di sistema di almeno 3 dB con una lunghezza d onda di 860 nm o di almeno 2 dB con una lunghezza d onda di 1300 nm Se il calcolo per la riserva di sistema dovesse dare come risultato un valore inferiore la linea di trasmissione nella forma progettata non affidabile a lungo termine Ci significa che una linea di trasmissione pu funzionare durante la messa in funzione in quanto la potenza dei componenti normalmente superiore di quella specificata in particolare con componenti nuovi ma a causa dell invecchiamento e della sostituzione dei componenti in seguito a riparazi
287. mentation SIMATIC NET PROFIBUS Networks 53 Copyright by Siemens Copyright by Siemens 54 SIEMENS Description and Operating Instructions OLM P11 SIMATIC NET PROFIBUS OLM P12 Optical Link Modules OLM G11 OLM G12 OLM G12 EEC OLM G11 1300 OLM G12 1300 Safety Instructions This manual contains instructions which must be observed to ensure your own personal safety and to avoid damage to devices and machinery The instructions are highlighted with a warning triangle and are shown as follows according to the degree of endangerment Danger safety measures are not taken Warning safety measures are not taken Caution PEE taken Note means that death serious injury or considerable damage to property will result if the appropriate means that death serious injury or considerable damage to property can result if the appropriate means that light injury or damage to property can result if the appropriate safety measures are not is an important piece of information about the product how to use the product or the relevant section of the documentation to which particular attention is to be drawn Qualified personnel A device may only be put into operation and operated by qualified personnel Qualified personnel in the sense of the safety instructions detailed in this manual are persons who are authorized to operate ground and label devices systems and electrical circuits in accordance with the st
288. mento di base PVC grigio copolimero arancione FRNC Scarico di tiro Filati aramidici e Filati aramidici filati di vetro Guaina esterna PVC nero Copolimero colore del cavo arancione chiaro FRNC Dimensioni 3 5 0 2 mm 2 9 mm elemento di base Dimensioni esterne 6 3 x 9 8 0 4 mm ca 3 9 x 6 8 mm Peso del cavo ca 74 kg km ca 30 kg km Forza di tiro ammessa lt 370 N in esercizio lt 500 N momentanea lt 200 N in esercizio lt 800 N momentanea Raggi di curvatura 100 mm solo sul lato piatto 100 mm durante la posa 60 mm in esercizio solo sul lato piatto Resistenza alla pressione trasversale 5 000 N 10 cm 3 000 N 10 cm momentanea 1 000 N 10 cm continuativa 7 14 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Tabella 7 4 Dati tecnici del cavo INDOOR Fiber Optic e del cavo Fiber Optic standard Tipo di cavo Resistenza ai colpi Fiber Optic Cavo standard 3 copi energia iniziale 5 Nm Raggio del martello 300 mm INDOOR Fiber Optic Cavo per l installazione all in terno di edifici 3 copi energia iniziale 1 5 Nm Raggio del martello 300 mm Temperatura per la posa da 5 C a 50 C da 5 C a 50 C Temperatura d esercizio da 25 C a 60 C da 20 C a 60 C Temperatura di magazzinaggio da
289. mento di protezione Avvolgimento KA Maglia in rame Rivestimento complessivo Guaina esterna Figura 7 8 Struttura del cavo marino duplex in fibra ottica SIENOPYR Cavo marino in fibra ottica duplex SIENOPYR 6XV1 830 0NH10 Il cavo marino duplex in fibra ottica SIENOPYR composto da 2 fibre a gradiente d indice multimode 62 5 125 um Inoltre contiene 2 conduttori multipli con isola mento in gomma con sezione di 1 mm Questi cavi permettono p es l alimenta zione degli apparecchi allacciati La sezione rotonda del cavo semplifica la tenuta dei passaggi dei cavi La guaina esterna riporta la data di produzione e la scritta SIENOPYR FR MI VHH 2G 62 5 125 3 1B200 0 8F600 2x1CU 300V ogni ca 50 cm Propriet Il cavo marino duplex in fibra ottica SIENOPYR presenta le seguenti propriet 7 22 resistenza a ozono secondo DIN VDE 0472 parte 805 classe di prova B comportamento alla combustione secondo IEC 60332 3 cat A corrosivita dei gas di combustione secondo IEC 60754 2 ermeticita al fumo IEC 61034 esente da alogeni collaudato dall industria navale Germanischer Lloyd Lloyd s Register Registro Italiano Navale Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Impiego Il cavo marino duplex in fibra ottica SIENOPYR previsto per l installazione fissa su navi e unit offshore in tutti i locali e all aperto Esso adatto per il collega mento d
290. n PROFIBUS ILMs with n subnets or DTEs without master functionality In a point to multipoint link the optical contact between the master network and the subnets is necessary For a PROFIBUS ILM with purely slave subnets an unobstructed view between them is not necessary Possible topologies are illustrated below based on sample configurations Copyright by Siemens 10 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 5 2 1 Point to Point Link Infrared transmission link 0 5 to 15m LR TREE ine PROFIBUS PROFIBUS master network segment slave network segment Figure 2 Point to Point Link with Two PROFIBUS ILMs Figure 2 describes the typical layout of a PROFIBUS network with master and slave nodes and an infrared transmission link with two PROFIBUS ILMs The infrared transmission link is implemented as a point to point link by the two PROFIBUS ILMs In this situation the two PROFIBUS ILMs replace a cable connection between the two network segments Remember that only slave nodes are permitted in the slave network segments amp Make sure that the terminating resistors are activated at the segment ends either in the bus connector or in a PROFIBUS ILM Cascading is a further application for a point to point link Note This cascading with PROFIBUS ILM mode is possible but does involve a risk when operating PROFIBUS The transmission using an infrared link is gene
291. n caso di necessit Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS 1 2 5 Metodo trasmissivo per componenti ottici Direttiva PNO Il metodo trasmissivo ottico conforme alla direttiva PNO Tecnica trasmissiva ottica per PROFIBUS 3 Interfacce ottiche integrate OBT OLM Vantaggi L alternativa ottica di SIMATIC NET PROFIBUS viene realizzata con le interfacce ottiche i bus terminal OBT e i Optical Link Module OLM integrati Come mezzo trasmissivo vengono impiegati cavi in fibra ottica duplex con fibre di vetro PCF o plastica cavi in fibra ottica duplex sono composti da 2 fibre che conducono il raggio di luce raggruppate in un cavo con un unico rivestimento Le unit con interfacce ottiche e bus terminal integrati OBT possono essere atti vate insieme in una rete ottica solo con una struttura lineare Gli OLM permettono di realizzare reti ottiche con struttura lineare a stella e ad anello La struttura ad anello permette un percorso di trasmissione del segnale ri dondante e forma una rete con elevata disponibilit e possono essere realizzate lunghe distanza tra due terminali indipendentemente dalla velocit di trasmissione collegamenti OLM OLM fino a 15 000 m e separazione galvanica tra nodi e mezzo trasmissivo e in caso di collegamenti con parti dell impianto con potenziale di terra diverso non si verificano correnti di dispersione e immunit a dist
292. n un repeater RS 485 nel quale ogni cavo di bus sul repeater passante Segmento 1 CS E 1 u u m Segmento 1 Resistenza terminale K Segmento di bus 1 F non attivare Resistenza terminale Segmento di bus 2 Segmento 2 non attivare eeee Segmento 2 6 _ 6 al I u E Cm me Co Figura 5 5 Allacciamento di due elementi di bus al repeater RS 485 Avvertenza Disattivando la tensione di alimentazione di un segmento completo non vengono alimentate nemmeno le resistenze terminali del bus sui nodi allacciati Di conse guenza in questo segmento possono verificarsi disturbi o stati di segnale indefiniti che non vengono riconosciuiti dal repeater e che possono comportare disturbi an che in altri segmenti Per questo motivo raccomandiamo di procedere nel modo seguente e Alternativa 1 Scollegare entrambi i segmenti prima di disattivare la tensione di alimentazione con l aiuto dell interruttore 5 tabella Descrizione e funzioni del repeater RS 485 sul repeater posizione OFF e Alternativa 2 Allacciare il repeater alla tensione di alimentazione del segmento da disattivare in modo che anche quest ultimo venga disattivato In questo caso fare tuttavia attenzione che il repeater non si trovi sull estremita del segmento precedente in quando il repeater rappresenterebbe la chiusura del bus che dive
293. na valutazione sulla qualit del manuale rispondendo alle seguenti domande Corrisponde alle Vostre esigenze il contenuto del manuale E facile trovare le informazioni necessarie Le informazioni sono spiegate in modo sufficientemente chiaro Corrisponde alle Vostre esigenze il livello delle informazioni tecniche AU DS Come valutate la qualit delle illustrazioni e delle tabelle Se avete riscontrato dei problemi di ordine pratico Vi preghiamo di delucidarli nelle seguenti righe PROFIBUS Optical 2 Busterminal OBT C79000 G8972 C122 02 Informazioni generali H 1 Indice delle abbreviazioni AI Alluminio AS Interface Aktuator Sensor Interface AWG American Wire Gauge BER Bit Error Rate tasso di errore sui bit BFOC Bajonet Fiber Optic Connector CP Communication Processor CSMA CD Carrier Sense Multiple Access Collision Detection Cu Rame DIN Norma industriale tedesca DP Periferia decentrata ESD Componenii elettrostatici EIA Electronic Industries Association EN Norma europea EMC Compatibilit elettrimagnetica FC Fast Connect FMS Fieldbus Message Specification FO Fiber Optics FRNC Flame Retardant Non Corrosive HCS Hard Cladded Silica IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronic Engineers ILM Infrared Link Module ISO OSI International Standards Organization Open System Interconnec
294. ne e curvatura eccessiva Le seguenti avvertenze forniscono un aiuto per evitare danni durante la posa dei cavi di bus cavi sottoposti ad un carico eccessivo dovuto ad una o pi delle cause indicate sopra devono essere sempre sostituiti Magazzinaggio e trasporto Durante il magazzinaggio il trasporto e la posa il cavo di bus non confezionato deve rimanere chiuso su entrambi i lati con cuffie a restringere per evitare l ossida zione dei singoli conduttori e i depositi di umidit nel cavo Temperature Durante il trasporto la posa e il funzionamento i cavi non devono essere esposti a temperature superiori o inferiori ai valori specificati in quanto potrebbero venire compromesse le loro propriet campi di temperatura ammessi per i cavi di bus sono riportati nei fogli dei dati tecnici dei cavi di bus nel capitolo 4 Resistenza alla trazione Le forze di trazione che agiscono sui cavi non devono superare il limite massimo di trazione dei cavi n durante n dopo l installazione carichi di trazione ammessi per i cavi di bus sono riportati nei fogli dei dati tecnici dei cavi di bus nel capitolo 4 Inserimento dei cavi confezionati utilizzando calze di protezione protezione dei connettori Per inserire i cavi utilizzare calze di protezione Prima di applicare la calza di prote zione necessario proteggere i connettori dei cavi confezionati contro la pressione dovuta al restringimento della calza utilizzando p es un p
295. ne ottico i cavi FO sono immuni a disturbi elettromagnetici Impiegando cavi in fibra ottica non sono necessarie misure equipotenziali di protezione contro sovratensioni Installazione dei cavi di bus elettrici in conformit di EMC Per l installazione conforme a EMC di cavi di bus elettrici fuori da edifici necessa rio rispettare le stesse regole valide per l installazione di cavi all interno di edifici Osservare inoltre quanto segue Installare i cavi su portacavi metallici Collegare galvanicamente tra loro i punti di urto dei portacavi Collegare a terra i portacavi necessario garantire un equipotenzialit sufficiente tra edifici e dispositivi esterni indipendentemente dai cavi di bus vedere capitolo C 4 4 del pre sente manuale cavi devono essere installati possibilmente nelle immediate vicinanze e paral leli all equipotenzialita Gli schermi dei cavi devono essere collegati possibilmente nelle immediate vici nanze del punto di ingresso degli edifici o i dispositivi devono essere collegati alla rete di terra cavi di bus elettrici installati fuori da edifici devono essere inclusi nel concetto di protezione antifulmini e di collegamento a terra dell intero impianto Osservare a tal proposito le istruzioni riportate nell appendice B del presente manuale Per l installazione dei cavi in canali con protezione contro umidit possono es sere utilizzati tutti i cavi SIMATIC NET PROFIBUS In questo caso necessar
296. nfezionato con 2x2 connettori BFOC Questo cavo disponibile anche gi confezionato Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 7 Componenti passivi per reti ottiche Propriet Il cavo in fibra ottica di plastica cavo standard 6XV 1821 0A e Non adatto per forza di tiro continuativa e resistente con limitazioni all olio minerale ASTM N 2 e resistente con limitazione al grasso minerale e resistente con limitazioni all acqua e resistente con limitazioni a radiazioni UV e resistente alla fiamma in base al test VW 1 secondo UL 1581 Impiego Il cavo in fibra ottica di plastica cavo standard 6XV1821 0A un cavo rotondo resistente per l impiego all interno di edifici La lunghezza massima realizzabile per una linea di 80 m con collegamenti OLM P e di 50 m con interfacce ottiche inte grate o OBT Tabelle 7 3 Numero di ordinazione per il Plastik Fiber Optic cavo standard Dati per l ordinazione Plastic Fiber Optic cavo standard a metraggio per OLM OBT e interfacce ottiche integrate SIMATIC NET PROFIBUS Plastic Fiber Optic cavo standard I VY4Y2P 980 1000 160A Cavo rotondo resistente con 2 conduttori FO in plastica guaina esterna in PVC e guaina interna in PA senza connettore per l impiego all interno di edifici a metraggio 6XV1821 0AH10 anello di 50 m 6VX1821 0AN50 anello di 100 m 6XV1821 0AT10 Reti PROFIBUS SIMATIC NET 7 8 6GK1970 5CA20 0AA4 Edizione 2 05 20
297. nfrarossi senza fili La tecnica trasmissiva a raggi infrarossi senza fili ha le seguenti propriet Topologia della rete Punto a punto Puno a multipunto Mezzo Spazio libero con collegamento a vista Lunghezze di collegamento 15m realizzabili Velocit di trasmissione ILM 9 6 kbit s 19 2 kbit s 45 45kbit s 93 75 kbit s 187 5 kbit s 500 kbit s 1 5 Mbit s Reti PROFIBUS SIMATIC NET 1 14 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS 1 2 7 Metodo trasmissivo per PROFIBUS PA Norma IEC 61158 2 Il metodo trasmissivo corrisponde alla norma IEC 61158 2 identico a EN 61158 2 Il mezzo trasmissivo un cavo schermato a due conduttori intrecciati Il segnale viene trasmesso come flusso di dati sincrono con codice manchester con 31 25 kbit s Il cavo dei dati viene normalmente utilizzato contemporaneamente per l alimentazione degli apparecchi da campo Vantaggi e Semplice cablaggio grazie ai cavi a due conduttori intrecciati e Alimentazione remota possibile tramite conduttori del segnale e Possibilit di funzionamento a sicurezza intrinseca per settori con pericolo di esplosione e Topologia lineare e ad albero e Fino a 32 nodi per ogni segmento della linea Limitazioni e Velocit di trasmissione limitata a 31 25 kbit s Propriet della tecnica trasmissiva IEC 61158 2 Le propriet principali della tecnica trasmissiva secondo IEC 61158 2 sono Topologia della rete Topologia lineare a stella e ad alber
298. ngere fino a 248 elementi binari sull AS Interface 124 ingressi e 124 uscite In questo modo pos sibile combinare in modo ideale i vantaggi di PROFIBUS DP e AS Interface in un impianto La DP AS Interface Link 20 pu essere impiegata con il modo operativo standard AS Interface M2 Con questo modo operativo possono essere interro gati i bit di dati degli slave Vengono supportati i seguenti richiami master Modifica indirizzo Scrittura parametri Lettura dati di configurazione Impostazione modo di progettazione Progettazione configurazione reale Parametrizzazione La DP AS Interface Link 20 viene supportata da STEP 7 a partire dalla versione V4 1 e COM PROFIBUS a partire dalla versione V 3 2 Inoltre al manuale sono allegati i file di tipo e i file GSD Per il lato AS Interface non necessaria nessuna progettazione specifica la messa in funzione del lato AS Interface possibile an che senza PROFIBUS Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 33 Topologie delle reti SIMATIC NET PROFIBUS 2 5 8 Passaggio da PROFIBUS DP a instabus EIB Struttura SIEMENS 4061415 LIL fida DE Agar DP EIB Link Powe obey Em RA Br sud gt ea oo Cer Figura 2 24 DP EIB Link Il DP EIB Link permette un collegamento di entrambi i sistemi standard aperti per l automazione industriale PROFIBUS DP e l automazione di edifici instabus EIB In questo modo l elevata potenzialit de
299. nghezza d onda compreso tra 850 nm e 1300 nm Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 17 Componenti passivi per reti ottiche 7 3 2 Cavo per installazione all interno di edifici INDOOR Fiber Optic Guaina esterna Copolymer FRNC arancione c Guaina interna Copolymer FRNC grigia Elementi di tiro aramidici Rivestimento conduttori FRNC Fibra di vetro G62 5 125 um Figura 7 5 Struttura del cavo per l installazione all interno di edifici INDOOR Fiber Optic Cavo per l installazione all interno di edifici INDOOR Fiber Optic 6XV1820 7 Propriet Impiego 7 18 Il cavo per l installazione all interno di edifici INDOOR Fiber Optic composto da 2 fibre a gradiente d indice multimode 62 5 125 um La guaina esterna riporta la scritta SIEMENS SIMATIC NET INDOOR FIBER OP TIC 6XV1 820 7AH10 FRNC ogni ca 50 cm La marcatura in metri consiste in un trattino verticale e un numero a 4 cifre che facilita il calcolo della lunghezza di un cavo installato Il cavo per l installazione all interno di edifici INDOOR Fiber Optic presenta le se guenti propriet e calpesabile e resistente alla fiamma secondo IEC 60332 3 e in base a DIN VDE 0472 parte 804 classe di prova B e esente da alogeni e confezionato con 4 connetori BFOC disponibile con lunghezza compresa tra 0 5me100m Il cavo per l installazione all interno di edifici INDOOR Fiber Optic previsto per l impie
300. ni marginali possono essere e elettriche e ottiche e senza fili e combinate elettriche ottiche senza fili e elettriche a sicurezza intrinseca Informazioni generali relative al sistema SIMATIC NET Con SIMATIC NET viene contrassegnato l insieme di comunicazione degli appa recchi di automazione SIEMENS calcolatore di supervisione workstation e perso nal computer SIMATIC NET comprende e la rete di comunicazione composta dai mezzi trasmissivi dai relativi compo nenti di allacciamento e trasmissione e dalla tecnica trasmissiva appropriata e i protocolli e i servizi che servono per la trasmissione dei dati tra gli apparecchi sopraindicati e le unit del sistema di automazione o del computer che stabiliscono un collega mento con la LAN processore di comunicazione CP o interfaccia Per risolvere le varie applicazioni della tecnica di automazione SIMATIC NET mette a disposizione diverse reti di comunicazione a seconda delle esigenze La topologia degli ambienti degli edifici delle sale di fabbricazione e degli interi complessi industriali nonch le condizioni ambientali determinano le diverse esi genze Di conseguenza i componenti di automazione da collegare in rete richie dono al sistema di comunicazione diversi requisiti di potenzalit In base alle diverse esigenze SIMATIC NET propone le seguenti reti di comunica zione conformi a norme nazionali ed internazionali Reti PROFIBUS SIMATIC_NET 6GK197
301. nizes this condition and closes the optical line to an optical ring in the middle of this request sequence This results in two configuration requirements for the redundant optical ring The value of the parameter HSA Highest Station Address must be set at all terminals so that between the bus address 0 and the value HSA at least one address in the network has not been assigned to a bus sub scriber i e so that there is at least one address gap This address gap can also be created by simply setting the value of the parameter HSA so that it is at least one greater than the highest number of subscriber bus addresses present in the network Attention If this requirement is not or no longer fulfilled the optical line will no longer be closed into a redundant optical ring after segmentation The error report LED and signaling contact of the two affected OLMs is not cancelled even after the error has been corrected The slot time must be set to approximately twice the value required in a non redundant network Further information can be found in Chapter 6 Configuration p 29 Refer to the manufacturer s documentation provided with the terminal or configuration software for details about how to adjust the settings 14 Version 1 1 8 00 4 Setting Up 4 1 Safety notice 4 Setting Up 4 1 Safety notice Only use the PROFIBUS OLM as described in this Description and Operating Instructions Pay particular attention to all th
302. nnettore 200 MA femmina PG OP e con utilizzatore collegato al connettore fem 230 mA mina PG OP 5 V 90 mA e con utilizzatore collegato al connettore fem 300 mA mina PG OP 24 V 100 mA Separazione di potenziale s AC 500 V Velocit di trasmissione viene identificata auto maticamente dal repeater 9 6 kbit s 19 2 kbit s 45 45 kbit s 93 75 kbit s 187 5 kbit s 500 kbit s 1 5 Mbit s 3 Mbit s 6 Mbit s 12 Mbit s Classe di protezione IP 20 Dimensioni Lx Ax P in mm 45x 1281 67 Peso compresa confezione 350g Assegnazione dei pin del connettore D Sub connettore femmina PG OP Il connettore D Sub a 9 poli presenta la seguente assegnazione dei pin Tabella 5 3 Assegnazione dei pin del connettore D Sub a 9 poli connettore femmina PG OP Figura N pin Nome se Denominazione gnale 1 z N 2 M24v Massa 24 V ad 3 RxD TxD P Cavo dati B 4 4 RTS Request To Send e Ie 5 M5V2 Potenziale di riferimento dati dalla stazione 7 35 6 P5V2 Alimentazione positiva dalla stazione er 7 P24V 24 V 8 RxD TxD N Cavo dati A 9 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 Schema elettrico La figura5 1 illustra lo schema elettrico del repeater RS 485 e segmenti di bus 1 e 2 presentano una separazione di potenziale tra loro e II segmento 2 e il connettore femmina PG OP pres
303. ns mission link distance between PROFIBUS ILMs too great PROFIBUS ILM turned out of line with partner station Risk of problems on bus due to incidence of ex traneous light for example sunlight lamps with infrared component halogen lamps with high energy Bus problems must be expected due to incidence of extraneous light with high frequency modula tion for example energy saving lamps with HF switching device Possible problems operating the PROFIBUS ILM Signaling Contact Signals when configured acknowledg ment pulse Signals if configured acknowledg ment pulse level monito ring Signals when configured bus activity Signals when configured level monito ring Signals when configured constant light Signals when configured constant light Copyright by Siemens 42 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM If no display indicates an error and communications problems nevertheless occur check the parameters set on both PROFIBUS nodes You should also check the electrical RS 485 wiring The most common cause of problems is activating or deactivating the terminating resistor incorrectly You should also check that the cable shields at the ends of all PROFIBUS cables and all shielded power supply cables are making satisfactory contact Note Remember that sporadic data errors on the cable network are not detected by the PROFIBUS ILM The PROFIBUS ILM cannot ch
304. nsabile per ogni utente l apparecchio di ricerca dei guasti FO Questa fonte di luce emette luce visibile in modo che fibre interrotte sdoppia menti difettosi ecc possano essere immediatamente localizzati in modo visibile Alcuni nuovi componenti di rete come p es PROFIBUS OLM della versione 3 dispongono di una possibilit di diagnostica integrata per poter controllare la qua lit del segnale ottico di ricezione Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 A 7 TECNICA DI MISURA PROFIBUS A 2 2 Metodo di attraversamento di raggi luminosi La linea FO deve essere dapprima sottoposta ad una misura dell attenuazione Tutti i componenti della linea come fibre connettori accoppiamenti e sdoppia menti contribuiscono all attenuazione complessiva della linea L attenuazione com plessiva deve trovarsi al di sotto del budget di potenza disponibile tra trasmettitore e ricevitore ottico Le fonti luminose e il misuratore ottico del cavo esistono per tutte le lunghezze d onda convenzionali 650 nm 850 nm e 1300 nm In questo modo il metodo di attraversamento di raggi luminosi pu essere utilizzato sia per FO in plastica PCF multimode sia per FO singlemode Assegnazione di misura per la misurazione dell attenuazione secondo il metodo di attraversamento di raggi luminosi A 8 L assegnazione di misura per la misurazione dell attenuazione composta da una fonte luminosa e da un dispositivo ottic
305. nta ineffi cace senza tensione di alimentazione Utilizzare eventualmente un PROFIBUS Terminator con tensione di alimentazione continua dopo il repeater e Alternativa 3 Se il repeater deve essere mantenuto senza tensione di alimentazione nel segmento da disattivare utilizzare come chiusura di bus PROFIBUS Terminator che devono rimanere senza alimentazione Se il segmento di bus da disattivare termina sul repeater necessario 1 terminator altrimenti sono necessari 2 ter minator Reti PROFIBUS SIMATIC NET 5 8 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 5 3 Montaggio e smontaggio del repeater RS 485 Panoramica Il repeater RS 485 pu essere montato nel modo seguente e su una guida profilata per S7 300 oppure e su una guida profilata a norma numero di ordinazione 6ES5 710 8MA Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 5 9 Componenti attivi per reti RS485 Montaggio su una guida profilata per S7 300 Per montare il repeater RS 485 su una guida profilata per S7 300 necessario togliere dapprima la slitta sul lato posteriore del repeater RS 485 vedere fi gura 5 6 1 2 Far passare un cacciavite sotto al supporto dell elemento di arresto 1 Spostare il cacciavite verso il lato posteriore dell unit 2 Mantenere questa posizione Risultato in questo modo la slitta del repeater RS 485 viene sbloccata Utilizzando la mano libera spostare la
306. nte p es rame con superficie stagnata non allumi nio Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 39 Componenti passivi per reti RS 485 4 4 2 Collegamento del cavo di bus al connettore di bus 6ES7 972 0BA30 0XA0 Aspetto 6ES7 972 0BA30 0XA0 La figura 4 18 illustra il connettore di bus con numero di ordinazione 6ES7 972 0BA30 0XA0 Viti per il fis en saggio sulla stazione LS 2 Connettore D Sub a 4 9 poli per il collega mento alla stazione Vite del contenitore Figura 4 18 Connettore di bus numero di ordinazione 6ES7 972 0BA30 0XA0 Montaggio del cavo di bus Collegare il cavo di bus al connettore di bus con il numero di ordinazione 6ES7 972 0BA30 0XA0 nel modo seguente 1 Togliere l isolamento del cavo di bus in base alla figura 4 19 3 27 a gt SIEMENS A B 29 3 35 q gt SIEMENS A O B Figura 4 19 Lunghezza sulla quale togliere l isolamento per il connettore di bus 6ES7 972 0BA30 0XA0 Reti PROFIBUS SIMATIC NET 4 40 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 2 Aprire il contenitore del connettore di bus allentando le viti del contenitore e to gliendo il coperchio 3 Premere il cavo di bus nello scarico di tiro Lo schermo del cavo deve appog gia
307. nza tensione di ingresso da 7Va 12V Corrente minima a 5V per resistenze terminali Separazione di potenziale verso ingresso 24V Separazione in base alla funzione non separazione di sicurezza Canali ottici Fonte ottica LED Potenza ottica accoppiabile in fibra di plastica 980 1000 in fibra PCF 200 230 PROFIBUS Optical Busterminal OBT 7 1 C79000 G8972 C122 02 Dati tecnici Sensibilit ricevitore PR min PR max con fibra in plastica 980 1000 20 dBm 0 dBm con fibra PCF 200 230 22 dBm 2 dBm Lunghezza d onda da 640 nm a 660 nm Attenuazione di percorso ammessa del cavo a fibre ottiche con riserva sistema con fibra in plastica 980 1000 13 dB con fibra PCF 200 230 3 dB Distanza realizzabile con riserva sistema 3dB con fibra in plastica 980 1000 con attenuazione massima percorso 200 dB km da 0 1m a 50m con fibra PCF 200 230 con attenuazione massima percorso 10 dB km da 0 m a 300m Connettore del cavo a fibre ottiche Simplex Duplex Compatibilit elettromagnetica EMC Emissione di disturbi Classe valori limite A_ EN 55022 Resistenza contro scariche statiche Su allacciamento scherm e parti contenitore 6 kV scarico di contatto IEC 1000 4 2 Resistenza contro irradiamenti di alta frequenza 10 V m con 80 di modulazione di ampiezza a 1kHz 80MHz 1GHz ENV 50140 IEC 61000 4 3 10V m con 50 di rapporto d inserzione a 900MHz ENV 50 204 10 V
308. o Per la realizzazione della protezione di massima sono necessari e l elemento di base art N 919506 e il modulo di protezione tipo B art N 919510 e e i morsetti di allacciamento dello schermo art N 919508 Per proteggere la protezione di massima da effetti elettromagnetici e ambientali essa deve essere montata in un e contenitore di protezione art N 906055 Contemporaneamente possibile in questo modo il passaggio da cavo di collega mento a terra a cablaggio standard all interno di edifici Figura B 2 Protezione di massima installata all ingresso o all uscita dell edificio Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 B 5 Protezione contro fulmini e sovratensioni per cavi di bus che si estendono in pi edifici B 2 2 B 6 Istruzioni di installazione per protezione di fine La protezione di fine deve essere installata nelle vicinanze del primo nodo di bus dopo la protezione di massima Per la realizzazione della protezione di fine sono necessari e l elemento di base art N 919506 e il modulo di protezione MD HF art N 919570 e e i morsetti di allacciamento dello schermo art N 919508 La protezione di fine deve essere collegata possibilmente a bassa impedenza alla terra di riferimento del primo nodo di bus p es guida ad U collegata a terra per il montaggio in armadi di comando Per il montaggio della protezione di fine fuori da armadi di comando campo IP 65 o superiore
309. o Tabella 6 1 Indicatore LED Cause possibile di guasto LED L 24V spento Tensione di alimentazione interrotta OBT difettoso LED L 24V lampeggia La velocit di trasmissione non ha ancora potuto essere impostata LED CH1 spento Interruzione di uno o pi conduttori del cavo di bus RS485 conduttori A e B del cavo di bus RS485 sono allacciati scambiati Il nodo PROFIBUS allacciato difettoso o non trasmette Il nodo PROFIBUS non allacciato o il nodo PROFIBUS allacciato non inserito LED CH1 acceso conduttori A e B del cavo di bus RS485 sono allacciati scambiati nodi PROFIBUS segnalano Cortocircuito su cavo di bus RS485 tuttavia a GI RIS Interruzione di uno dei due conduttori del cavo di bus RS485 inoltre condut tori A e B allacciati scambiati Terminazione assente o errata LED CH2 CH3 spento Il cavo a fibre ottiche di trasmissione e quello di ricezione sono allacciati scambiati Interruzione del cavo a fibre ottiche di ricezione verso il modulo partner Nessun modulo partner allacciato o il modulo partner allacciato non inse rito ll modulo partner allacciato difettoso non trasmette LED CH2 CH3 acceso Il connettore del cavo a fibre ottiche allentato contatto difettoso I nodi PROFIBUS segnalano Lunghezza eccessiva percorso cavo a fibre ottiche verso modulo adiacente t ttavia dIsIuroreHoHe Interruzione del cavo a fibre ottiche di ricezione con incidenza di luce e
310. o Lunghezze di segmento realizzabili 1900 m Velocit di trasmissione 31 25 kbit s Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 1 Topologie delle reti SIMATIC NET PROFIBUS 2 1 Topologia delle reti RS 485 Velocit di trasmissione Per SIMATIC NET PROFIBUS con tecnica trasmissiva RS 485 l utente pu impo stare a scelta le velocit di trasmissione 9 6 kbit s 19 2 kbit s 45 45kbit s 93 75 kbit s 187 5 kbit s 500 kbit s 1 5 Mbit s 3 Mbit s 6 Mbit s o 12 Mbit s aggiustare A seconda della velocit di trasmissione del mezzo trasmissivo e dei componenti della rete possono essere realizzati segmenti di diverse lunghezze permettendo cos l estensione della rete componenti di allacciamento del bus si suddividono in due gruppi e componenti per velocit di trasmissione da 9 6 kbit s a max 1 5 Mbit s e componenti per velocit di trasmissione da 9 6 kbit s a max 12 Mbit s Cavo di bus Come mezzo trasmissivo vengono utilizzati i cavi di bus SIMATIC NET PROFIBUS descritti nel capitolo 4 Le specificazioni tecniche riportate qui di seguito si riferi scono solo a reti che vengono realizzate con questi cavi e componenti SIMATIC NET PROFIBUS Allacciamento dei nodi nodi vengono allacciati ai cavi di bus
311. o adattati tra di loro in base a queste esigenze Attenendosi alle direttive di montag gio descritte nei manuali di sistema si ottiene un sistema di automazione che ri sponde ai requisiti industriali di sicurezza e immunit ai disturbi stabiliti per legge Reti PROFIBUS SIMATIC NET C 2 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus C 2 Sicurezza elettrica Il livello del segnale sui cavi elettrici PROFIBUS si trova nel campo del basso vol taggio Se usati correttamente i cavi di bus PROFIBUS non conducono tensioni elettrice con pericolo di contatto Per l alimentazione di tutti i componenti nodi componenti di bus che si colle gano ad un cavo di bus PROFIBUS osservare tuttavia le seguenti regole Tensione di rete componenti comandati con tensione di rete verso l interfaccia PROFIBUS devono rispondere ai requisiti di separazione elettrica sicura dalla rete secondo DIN VDE 0160 e DIN IEC 950 VDE 0805 EN 60950 UL 1950 CSA 22 2 N 950 7 Alimentazione DC 24 V Le tensioni di alimentazione di DC 24 V condotta ad un componente deve rispon dere ai requisiti di tensione a basso voltaggio con separazione elettrica sicura dalla rete secondo DIN VDE 0160 e DIN IEC 950 VDE 0805 EN 60950 UL 1950 CSA 22 2 N 950 7 Protezione da agenti elettrici esterni Cavi o conduttori spezzati non devono comportare stati indefiniti dell impianto o del sistema Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0A
312. o di misurazione della potenza La fonte luminosa viene dapprima collegata al ricevitore con fibre di riferimento La potenza luminosa misurata dal ricevitore rappresenta il valore di riferimento per una linea senza attenuazione Successivamente le fibre di riferimento vengono scollegate e viene inserita la linea da misurare Il ricevitore di misura confronta la potenza lumi nosa ora ricevuta con il valore di riferimento precedentemente misurato e calcola con questi valori l attenuazione della linea inserita Passo 1 misurazione riferimento Fote luminosa Fote luminosa Passo 2 misurazione linea Misuratore ottico della potenz Figura A 2 Misurazione dell attenuazione complessiva di una linea FO Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 TECNICA DI MISURA PROFIBUS Analisi dei risultati della misurazione dell attenuazione A 2 3 Tra un trasmettitore ottico e un ricevitore ottico disponibile un budget di potenza Questo budget indica la differenza tra la potenza minima emessa dal trasmettitore e la potenza minima necessaria dal ricevitore Il budget di potenza viene normal mente indicato in dB L attenuazione complessiva misurata della linea FO deve essere inferiore a questo budget Tanto inferiore l attenuazione del budget di potenza quanto maggiore la sicu rezza di funzionamento e la stabilit di lunga durata della linea ottica La differenza budget ottico attenuazione
313. o standard PROFIBUS Entrambe le estremit di questo cavo sono munite di rispettivamente un connettore Sub D a 9 poli con uscita del cavo diritta e sull estremita opposta di un connettore Sub D a 9 poli con uscita cavo a 90 Il connettore con uscita cavo a 90 munito di un in terfaccia PG La combinazione di resistenze pu essere attivata in entrambi i con nettori Questo cavo disponibile con lunghezze di3m 5me 10m Figura 4 35 Cavo di connessione 830 2 Funzione Il cavo di connessione 830 2 collega e l interfaccia elettrica di Optical Link Module OLM OBT e l interfaccia PROFI BUS di un nodo PROFIBUS e l interfaccia elettrica di due nodi PROFIBUS OP apparecchi di automazione Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 67 Componenti passivi per reti RS 485 Tabelle 4 12 Dati per l ordinazione del cavo di connessione 830 2 SIMATIC NET Dati per l ordinazione Cavo di connessione 830 2 SIMATIC NET per PROFIBUS per l allacciamento di terminali di dati a OLM e OBT preconfezionati con 2 connettori Sub D a 9 poli con resistenze terminali attivabili 3m 6XV1830 2AH30 5m 6XV1830 2AH50 10m 6XV1830 2AN10 Reti PROFIBUS SIMATIC NET 4 68 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 5 1 Componenti attivi per reti RS485 5 1 Repeater RS 485 Che cos un repeater RS 485 Un
314. oblems in operation Problems occurring during operation can also trigger a signaling contact allowing centralized monitoring of a system Copyright by Siemens 8 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM CH SIEMENS PROFIBUS ILM RX LOW ERROR e e 6GK1503 0AA00 Figure 1 PROFIBUS ILM The mechanical construction is a compact stable metal housing splash water protected with degree of protection IP65 The casing must be mounted by the user on a grounded surface with two screws When shipped the data rate is set to 1 5 Mbps the signaling contact is not activated if errors occur and the terminating resistor is not activated 9 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 5 Description of the Functions 5 1 Transmission Rate The SIMATIC NET PROFIBUS ILM supports the following transmission rates 9 6 Kbps 19 2 Kbps 45 45 Kbps 93 75 Kbps 187 5 Kbps 500 Kbps 1 5 Mbps default The transmission rates of the connected network nodes can have the tolerance of 0 3 as specified in the PROFIBUS standard 5 2 Topologies The PROFIBUS ILM can be used in two topologies gt The point to point link between two PROFIBUS ILMs where one or more master or slave nodes can be attached to one subnet and one or more slave nodes can be attached to the other gt The point to multipoint link between a PROFIBUS ILM to which a subnet with one or more masters or slaves is connected and
315. oduct is put into operation it must be ensured that it conforms with the directive 89 392 EEC Version 1 1 8 00 33 8 Appendix 8 2 Literature notes 8 2 Literature notes Manual SIMATC NET PROFIBUS Networks SIEMENS AG 6GK1970 5CA20 0AA0 German DAA1 English DAA2 French DAAA Italian EN 50170 1 2 1996 General Purpose Field Communication System Volume 2 Physical Layer Spezification and Service Definition DIN 19245 Messen Steuern Regeln PROFIBUS Teil 3 Process Field Bus Dezentrale Peripherie DP Measuring controlling governing PROFIBUS Part 3 Process Field Bus Decentral Periphery Devices DP EIA Standard RS 485 April 1983 Standard for electrical characteristics of generators 8 3 List of abbreviations BFOC Bayonet Fiber Optic Connector DIN Deutsche Industrie Norm German Industrial Standard EEC Extended Environmental Conditions EIA Electronic Industries Association EN Europ ische Norm European Standard EMC Electromagnetic Compatibility HCS Hard Polymer Cladded Silica Fiber registered trademark of Ensign Bickford IEC International Electrotechnical Commission LED Light Emitting Diode OBT Optical Bus Terminal OLM Optical Link Module PCF Polymer Cladded Fiber equal to HCS PNO PROFIBUS Nutzer Organisation PROFIBUS User Organization SELV Secure Electrical Low Voltage UL Underwriter Laboratories VDE Verein Deutscher Elektroingenieure Association of Ge
316. of the PROFIBUS ILM of the receiving PROFIBUS node After filtering and decoding an electrical signal is available on the receiving PROFIBUS ILM that is then transferred via the PROFIBUS cable to the receiving PROFIBUS node The data transmission is half duplex as normal in PROFIBUS in other words at any point in time only one node can send while all others receive Each node can however send and receive A wireless link between PROFIBUS ILM and data light barriers of other manufacturers is not possible due to the differences in the optical transmission techniques The electrical channel of the PROFIBUS ILM uses the RS 485 transmission technique which is typical for PROFIBUS and processes the standard data rates of 9600 bps to 1 5 Mbps The data rate must be set by the user The electrical channel is connected via SIMATIC NET PROFIBUS cables for ordering data see Catalog IK10 The cables enter the casing via heavy duty threaded cable inlets The shield makes contact here and the wires are connected using screw type terminals The PROFIBUS ILM can be used at any position in an electrical PROFIBUS network When it is connected at the end of asegment the user must activate a terminating resistor The operating voltage is an intrinsically safe 24 V direct voltage and is connected just as the PROFIBUS cables by feeding the cable through a heavy duty threaded cable inlet to a terminal block LEDs signal the correct operating status and any pr
317. oli minerali grassi e oli mi nerali nerali nerali nerali Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 3 Componenti passivi per reti RS 485 1 Propriet elettriche 20 C prove secondo DIN 47250 parte 4 o DIN VDE 0472 2 Cavi da trascinamento adatti alle seguenti esigenze min 4 milioni di cicli di curvatura con il raggio di curvatura specificato e un accelerazione di max 4 m s Diametro esterno gt 8 mm i connettori di bus possono essere allacciati solo dopo aver rimosso la guaina esterna Non adatto per l allacciamento al connettore di bus con tecnica a perforazione d isolante 6ES7 972 0BA30 0XA0 Lunghezze del segmento limitate Velocit di trasmissione 31 25 kbit s Lunghezza del cavo 180 Reti PROFIBUS SIMATIC NET 4 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Tabella 4 2 Dati tecnici 1 Tipo di cavo N di ordinazione Attenuazione a 16 a 4 a 38 4 kHz 9 6 kHZ Impedenza caratteristica a 9 6 kHz a 31 25 kHz a 38 4 kHz a 3 fino a 20 MHz Valore nominale MHz MHz Resistenza del conduttore Resistenza dello schermo Capacit in esercizio a 1 kHz Tensione d esercizio valore efficace Tipo di cavo Sigla identificativa a norma Guaina esterna Materiale Colore Diametro Condizioni ambientali ammesse Temperatura d esercizio Temperatura di trasporto di magazzinaggio Temperatura di posa Raggi di curva
318. ollegamento tra slave DP e in modo decentrato con Plastic Fiber Optic di stanze lt 50 m e collegamento tra master DP e il primo slave DP della topologia lineare con PCF Fiber Optic distanza gt 50 m Calcolo dell attenuazione del segnale di linee di trasmissione FO in fibra di vetro con OLM calcolo seguenti fogli riportano esempi di calcolo del budget di attenuazione per cavi FO in fibra di vetro per SIMATIC NET PROFIBUS con OLM G11 OLM G12 con una lunghezza d onda di 860 nm e con OLM G11 1300 e OLW G12 1300 con una lun ghezza d onda di 1300 nm Avvertenza Fare attenzione che le specificazioni per l attenuazione della fibra riportate nei fogli dei dati e nelle definizioni del tipo dei cavi in fibra ottica sono basate su misura zioni eseguite con fonti di luce laser a banda stretta Gli elementi di trasmissione a LED impiegati generano uno spettro a banda larga la frequenza media del quale si scosta leggermente dalla lunghezza d onda di mi sura Di conseguenza eseguire il calcolo per tutti i collegamenti con FO in fibra di vetro multimode SIMATIC NET tra componenti SIMATIC NET PROFIBUS con i seguenti valori di attenuazione 3 5 dB km con 860 nm 1 0 dB km con 1310 nm Avvertenza Le seguenti lunghezze di linea tra 2 OLM non devono essere in nessun caso superate indipendentemente dal bilancio ottico della potenzialit OLM P11 OLM P12 400 m OLM G11 OLM G12 OLM G12 EEC 3 km OLM G 11 1300 OLM G12 1
319. on OLM Il collega mento di linee di vetro ad una linea ottica delle interfacce ottiche integrate viene eseguita tramite l interfaccia RS 485 di un OBT La seguente figura illustra un esempio applicativo ET 200M con IM 153 2 FO Apparecchiatura da campo senza interfaccia 2 altri nodi fino a 15 km Resistenza terminale attivata 1 cavo in fibra ottica 3 Cavo di connessione PROFIBUS 830 1T 2 cavo di bus PROFIBUS 4 Cavo di connessione PROFIBUS 830 2 Collegamenti di una linea ottica con fibre ottiche di vetro ad una linea ottica delle interfacce ottiche integrate Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS 2 3 Topologie di rete senza fili Infrared Link Module ILM In SIMATIC NET le reti PROFIBUS senza fili vengono realizzate con l Infrared Link Module ILM Figura 2 8 PROFIBUS ILM Lunghezza di linea realizzabile La lunghezza di linea realizzabile di 15 m indipendentemente dalla velocit di trasmissione raggi infrarossi che servono alla trasmissione dei dati vengono irradiati con un angolo di 10 intorno all asse centrale La conseguenza che un ILM ad una distanza di 11 m illumina una superficie circolare con diametro di 4 m Il partner di comunicazione deve trovarsi nel campo di questa superficie illuminata Tr
320. on according IEC 60825 1 1993 A1 1997 A2 2000 Version 1 1 8 00 15 4 Setting Up 4 2 General information about setting up 4 2 General information about setting up Select the network topology which is most suitable for your requirements The modules can then be put into operation in the following steps Check and adjust if necessary the DIL switch Note The DIL switches may only be operated in an ambient temperature of between 0 C and 60 C This also applies to the OLM G12 EEC Mount the modules Connect the power supply and the signaling contacts Connect the electric RS 485 bus line with pre mounted bus connector Connect the optical bus lines Trani 88866 fA Fig 5 Top view of the Module OLM location of the DIL switches and terminal block for the operating power supply signaling contacts The illustration shows the factory settings of the DIL switches switches SO S1 S2 S3 S4 and S7 in Position 0 switches S5 and S6 in Position 1 16 Version 1 1 8 00 4 Setting Up 4 3 Setting compatibility operating mode and transmitting power 4 3 Setting compatibility operating mode and transmitting power Please note The OLM must be switched off when changing the operating mode You can switch off the OLM by e g unplugging the 5 pin terminal block 4 3 1 Setting the compatibility The DIL switch S7 is used to switch the functional compatibi
321. on guaina interna in PVC e senza guaina esterna La guaina grigia e non stampigliata La sigla identificativa a norma I VY2P 980 1000 150 Il cavo pu essere facilmente confezionato nel luogo di installazione Per apparec chi con interfacce ottiche integrate il cavo previsto con 2x2 connettori simplex Per l impiego di OLM P11 e OLM P12 il cavo deve essere confezionato con 2x2 connettori BFOC Propriet Il cavo in fibra ottica di plastica con conduttori duplex 6XV1821 2AN50 e Non adatto per forza di tiro continuativa e resistente con limitazioni all olio minerale ASTM N 2 e resistente con limitazione al grasso minerale e resistente con limitazioni all acqua e non resistente a radiazioni UV e resistente alla fiamma in base al test VW 1 secondo UL 1581 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 5 Componenti passivi per reti ottiche Impiego Il cavo in fibra ottica di plastica con conduttori duplex 6XV1821 2AN50 previsto per l impiego all interno di ediici con carico meccanico ridotto come p es labora tori o all interno di armadi Il cavo viene fornito in anelli di 50 m Sia in caso di im piego di OLM sia con interfacce ottiche integrate con questo cavo possibile rea lizzare collegamenti lunghi fino a 50 m tra due nodi Tabelle 7 2 Numero di ordinazione per cavo in fibra ottica di plastica con conduttore duplex 6XV1821 2AN50 Cavo in fibra ottica Versioni
322. oni del cambiamento delle condizioni ambientali ecc il tasso di errore sui bit aumentando la durata di funzionamento pu superare i valori ammessi Avvertenza Per evitare possibili errori durante l installazione delle linee di trasmissione per i cavi in fibra ottica di vetro necessario misurare le linee intallate e registrare i va lori di misura prima della messa in funzione vedere capitolo A 2 Tecnica di mi sura per FO Nel capitolo 3 2 4 del presente manuale riportato un foglio per il calcolo del budget di attenuazione delle linee di trasmissione in fibra ottica di vetro Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti 3 2 3 Lunghezze dei cavi per linee FO con fibre di plastica e PCF Utilizzando cavi FO la lunghezza della linea di trasmissione non dipende dalla velocit di trasmissione Ogni nodo di bus sulla rete ottica PROFIBUS dispone della funzionalit di repeater in modo che le seguenti specificazioni si riferiscano alla distanza tra due nodi PROFIBUS collegati tra di loro e adiacenti La lunghezza massima del cavo tra due nodi PROFIBUS dipende del tipo di cavo in fibra ottica e dai componenti di rete ottici utilizzati Tabella 3 7 Lunghezze di cavo ammesse con interfaccia ottica integrata o OBT Cavo in fibra ottica Lunghezze massime del Calcolato su 1 rete cavo standard SIMATIC NET cavo 32 nodi in m PROFIBUS tr
323. onmental conditions Oscillation during operation Oscillation during transportation Degree of protection Weight Dimensions Casing material VDE 0806 EN60950 and IEC950 Requirements are met 0 C to 60 C IEC 68 2 1 IEC 68 2 2 40 C to 70 C IEC 68 2 14 lt 95 none condensing IEC 68 2 30 If condensation forms on the window there is a tempo rary reduction in the distance that can be covered There is no permanent functional disturbance and no damage to the electronics if the threaded cable inlet ful fills the requirements of IP65 10 to 58 Hz 0 075 mm deflection 58 to 150 Hz 10 m s 1g acceleration IEC 68 2 6 5 to 9 Hz 3 5 mm deflection 9 to 500 Hz 10m s 1g acceleration Table 4 Environmental Conditions for the Use of the PROFIBUS ILM Copyright by Siemens 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 11 1 Illumination Range To determine the arrangement of two PROFIBUS ILMs on an infrared transmission link the illumination range of the sending PROFIBUS ILM must be known The receive cone is broader so that with the half duplex transmission used with PROFIBUS the restriction results from the narrower cone Note Each PROFIBUS ILM on an infrared link must be arranged and aligned so that it reaches its partner with its transmit cone The illumination range of the sender is shown in Figure 19 In the range from 0 5 to 12 m there is adequate illumination den
324. ono convertiti in segnali elettrici e e trasmessi al canale 1 come segnali elettrici e riconvertiti in segnali ottici e ritrasmessi all altro canale ottico Sul canale di ricezione non si verifica nessun eco cio i segnali ricevuti non veng gono ritrasmessi sullo stesso canale L OBT rigenera i segnali in ampiezza e tempo In questo modo in una linea ottica possibile collegare in cascata fino a 126 moduli La profondit di cascata viene li mitata solo dai tempi di controllo dei dispositivi allacciati Il ritardo di attraversamento per ogni OBT di 6 tempi di bit PROFIBUS Optical Busterminal OBT 3 1 C79000 G8972 C1 22 02 Descrizione del funzionamento 3 3 3 4 3 5 3 2 Identificazione automatica della velocit di trasmissione L OBT supporta tutte le velocit di trasmissione PROFIBUS 12 MBit s 6 MBit s 3 MBit s 1 5 MBit s 500 kBit s e 187 5 kBit s 93 75 kBit s 45 45 kBit s 19 2 kBit s 9 6 kBit s La velocita di trasmissione viene determinata automaticamente Non sono neces sarie impostazioni Tipi di fibre ottiche supportate L OBT supporta i tipi di fibra elencati nella seguente tabella Tabella 3 1 Distanza di FO realizzabili tra due dispositivi su PROFIBUS DP ottico Tipo di fibra Lunghezza percorso tra due dispositivi FO in plastica 980 1000 um con 2 fibre e da 0 1ma50m attenuazione massima di percorso 200 dB km FO PCF 200 230 um con 2 fibre e da 0 m a 300 m attenuazione mas
325. onversione elettro ottica viene garantita una se parazione atuomatica del potenziale in modo che le differenze di potenziale come p es possono verificarsi in impianti estesi non siano pi percettibili 1 HCS un marchio registrato di Ensign Bickford Optics Company e sta per Hard Polymer Cladded Silica Fiber Cos come i cavi a fibre ottiche sono immuni agli irradiamenti EMC il cavo a fibre ottiche non emette onde elettromagnetiche nell ambiente dispositivi elettrici sen sibili disposti nelle vicinanze del cavo a fibre ottiche non necessitano quindi di prov vedimenti di protezione o antidisturbo supplementari Alimentazione Per il funzionamento l OBT necessita di tensione di alimentazione continua di 24V che viene allacciata con due morsetti a vite Stato di funzionamento Dei diodi luminosi segnalano lo stato di funzionamento attuale ed eventuali disturbi di funzionamento Struttura meccanica 1 2 La struttura meccanica costituita da un contenitore di plastica compatto che pu essere montato a scelta su una guida ad U o su una qualsiasi base piana PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Fornitura di SIMATIC NET PROFIBUS OBT 2 Volume di fornitura 1 PROFIBUS OBT 1 modulo di richiesta per le istruzioni per uso PROFIBUS OBT Non compreso nella fornitura e Cavo a fibre ottiche in plastica a metraggio e Attrezzo di montaggio per connettore cavo a fibre ottiche e Istruzioni per
326. opriet elettriche e meccaniche Se dovesse essere necessario un cavo con propriet con comprese nella gamma di prodotti descritta in questo capitolo rivolgersi alla filiale SIEMENS pi vicina o ad uno dei consulenti elencati nell appendice 1 2 Reti PROFIBUS SIMATIC NET 4 2 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Tabella 4 1 Cavi di bus per PROFIBUS 1 Dati tecnici 1 FC Standard FCFRNC Ca FC Food Ca FC Robust FC Under Tipo di cavo Cable ble ble Cable ground cable N di ordinazione 6XV1 830 6XV1 830 6XV1 830 6XV1 830 6XV1 830 0EH10 OLH10 0GH10 04H10 3FH10 Attenuazione a 16 MHz lt 42 dB km lt 42 dB km lt 42 dB km lt 42 dB km a 4 MHz lt 22 dB km lt 22 dB km lt 22 dB km lt 22 dB km a 38 4 kHz lt 4 dB km lt 4 dB km lt 4 dB km lt 4 dB km 9 6 kHZ lt 2 5 dB km lt 2 5 dB km lt 2 5 dB km lt 2 5 dB km Impedenza caratteristica a 9 6 kHz a 31 25 kHz a 38 4 kHz a 3 fino a 20 MHz Valore nominale Resistenza del conduttore lt 110 Q km lt 110 Q km lt 110 Q km lt 110 Q km lt 110 Q km Resistenza dello schermo lt 9 5 Q km lt 9 5 Q km lt 9 5 Q km lt 9 5 Q km lt 9 5 Q km ca 28 5 nF km ca 28 5 nF km ca 28 5 nF km ca 28 5 nF km ca 28 5 nF km 1 kHz Tensione d esercizio lt 100V lt 100V lt 100V lt 100V lt 100V valore efficace Tipo di cavo 02YY ST CY 02YSH ST CH 02YSY ST C2 02YSY ST C11 02YSY ST Sigla identificativa a norma
327. or device using two screws Ground the PROFIBUS ILM with low resistance Connect the PROFIBUS cable s and the power supply and signaling contact cable In awkward locations it is sometimes better to connect the cables before actually mounting the modules Depending on your bus topology activate or deactivate the terminating resistor active when the ILM is at the end of the cable deactivated if the ILM is looped into the cable Set the transmission rate configured in the PROFIBUS network to the same setting on all PROFIBUS ILMs of a PROFIBUS network using the switches Set the monitor link with acknowledgment pulse mode for a point to point link if required Set the errors to trigger the signaling contact using the switch if you want to use the signaling contact for monitoring Plug in the ribbon cable of the electronics section into one of the coded plug connectors on the basic module The plug connectors are coded to prevent reverse polarity Replace the top cover of the PROFIBUS ILM using the four cover screws Align the PROFIBUS ILM to the partner station so that the emission of the PROFIBUS ILM is along the optical axis to the partner ILM Test the arrangement with power applied but without data exchange Only the green POWER LED must be lit Test the transmission link with data exchange The yellow TX and RX LEDs should be lit as well as the green power LED The red FRROR LED must not be lit since this indicat
328. ori capacitivi vedere tabella 3 4 Le interfacce PROFIBUS realizzati come connettori femmina Sub D a 9 poli CP OLM non dispongono di un fattore capacitivo proprio Esse sono gi state calco late nei valori riportati nella tabella Tabella 3 4 Fattori capacitivi per segmenti con 1 5 Mbit s Denominazione del prodotto Fattore capacitivo W Bus terminal con cavo di derivazione lunghezza 1 5 m N di ordinazione 6GK1 500 0AA00 versione 2 Bus terminal con cavo di derivazione lunghezza 1 5 m con interfaccia PG N di ordinazione 6GK1 500 0DA00 versione 2 Bus terminal con cavo di derivazione lunghezza 3 0 m N di ordinazione 6GK1 500 0BA00 versione 2 Connettore di bus con uscita cavo a 30 N di ordinazione 6ES7 972 0BA30 0XA0 Connettore di bus con uscita cavo assiale N di ordinazione 6GK1 500 0EA02 Connettore di bus con uscita cavo assiale per sistema FastConnect N di ordinazione 6GK1 500 0FC00 Connettore di bus con uscita cavo a 90 N di ordinazione 6ES7 972 0BA11 0XA0 Connettore di bus con uscita cavo a 90 con interfaccia PG N di ordinazione 6ES7 972 0BB11 0XA0 Connettore di bus con uscita cavo a 90 per sistema FastConnect N di ordinazione 6ES7 972 0BA50 0XA0 Connettore di bus con uscita cavo a 90 con interfaccia PG N di ordinazione 6ES7 972 0BB50 0XA0 Connettore di bus con uscita cavo a 35 N di ordinazione 6ES7 972 0BA40 0XA0 Connettore di bus con uscita cavo a 35
329. ork parameter HSA is set too low no transmitting bus subscriber present one optical port is set to Redundant optical ring mode but not the second this operating mode must always be set at both optical ports the slot time of the network configuration is too short failure of both power supply sources with redundant infeed Signaling contact no signal signal no signal no signal 25 5 LED Indicators and Troubleshooting 5 1 LED Indicators LED Indicator CH1 lights yellow electric not lit flashes lights red CH2 CH3 lights yellow optical not lit flashes yellow lights red flashes red yellow lights yellow not lit Possible causes Signals are being received on the RS 485 bus line Bus subscriber is not connected Connected bus subscriber is not switched on One or both conductors in the RS 485 bus line is broken Sporadic interference signals because the RS 485 bus line being insufficiently shielded an open RS 485 bus line i e it is only connected to the module at one end the RS 485 segment is not terminated or only terminated at one end an RS 485 bus terminal or terminal connector has been plugged in pulled out Permanent interference because conductors A and B in the RS 485 bus line have been transposed of an RS 485 bus line short circuit the send time has been exceeded caused by a bus subscriber in a bus segment connected
330. orsetti L M e PE Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 5 6 Allacciamento del cavo di bus Tutti i cavi di bus descritti nel capitolo 4 sono adatti per l allacciamento al repeater RS 485 Allacciamento del cavo di bus PROFIBUS Allacciare il cavo di bus PROFIBUS al repeater RS 485 nel modo seguente 1 Tagliare il cavo di bus PROFIBUS nella lunghezza necessaria 2 Togliere l isolamento del cavo PROFIBUS in base alla figura 5 9 La maglia di schermatura deve essere risvoltata sul cavo Solo in questo modo la fascetta di schermatura pu successivamente servire come scarico di tiro e come elemento di schermatura p es Standard Cable p es Underground Cable 6XV1 830 0EH10 6XV1 830 3FH10 8 5 16 10 16 16 10 ama gt gt ENE de La maglia di schermatura deve essere risvoltata SIEMENS 8 5 Figura 5 9 Lunghezza su cui togliere l isolamento per l allacciamento al repeater RS 485 3 Allacciare il cavo di bus PROFIBUS al repeater RS 485 Allacciare i conduttori uguali verde rosso per cavo di bus PROFIBUS allo stesso allacciamento A o B collegare p es l allacciamento A sempre al filo verde e l allacciamento B sempre al filo rosso 4 Avvitare la fascetta di schermatura in modo che lo schermo appoggi diretta mente sulla fascetta di schermatura Reti PROFIBUS SIMATIC NET
331. ossibilit di impiego in aree soggette ad esplosioni Fornitura 5 pezzi 1 confezione 6GK1 905 0AD00 SpliTConnect Terminator non per aree sog gette ad esplosione per l allacciamento di segmenti di bus PROFI BUS PA non possibile l impiego in aree sog gette ad esplosioni Fornitura 5 pezzi 1 confezione 6GK1 905 0AE00 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 SIEMENS SIMATIC NET Produktinformation Product Information Stand Dated 10 99 Montageanleitung f r SIMATIC NET PROFIBUS SpliTConnect System Mounting Instructions for SIMATIC NET PROFIBUS SpliTConnect System SIEMENS AG 1999 Anderungen vorbehalten 039 242 001 03 1099 Subject to change Printed in Federal Republic of Germany Montageanleitung f r SIMATIC NET PROFIBUS SpliTConnect System Mounting Instruction for SIMATIC NET PROFIBUS SpliTConnect System Wir haben den Inhalt der Druckschrift auf Ubereinstimmung mit dem beschriebenen SpliTConnect System gepriift Dennoch k nnen Abweichungen nicht ausgeschlossen werden so da amp wir f r die vollst ndige bereinstimmung keine Gew hr ber nehmen Die Angaben in der Druckschrift werden jedoch regel m ig berpr ft Notwendige Korrekturen sind in den nach folgenden Auflagen enthalten F r Verbesserungsvorschl ge sind wir dankbar Technische nderungen vorbehalten Wichtiger Hinweis Wir weisen darauf hin da der Inhalt dieser Betriebs
332. ottiche integrate descritto dettagliata mente nel capitolo Componenti passivi per reti ottiche e nell appedice D Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 25 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Istruzioni di montaggio per SIMATIC NET PROFIBUS Plastic Fiber Optic con connettori simplex o connettori BFOC ed elemento ausiliare di inserimento per cavo standard Fiber Optic Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 D D 1 Istruzioni di montaggio per SIMATIC NET Reti PROFIBUS SIMATIC NET D 2 6GK1970 5CA20 0AA4 Edizione 2 05 2000 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors SIEMENS SIMATIC NET Product Information Dated 08 99 Installation Instructions for SIMATIC NET PROFIBUS Plastic Fiber Optic with Simplex Connectors This document contains information in English SIEMENS AG 1999 Page 1 Subject to change SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors We have checked the contents of this manual for The reproduction transmission or use of this document agreement with the tools described Since or its contents is not permitted without express written deviations cannot be precluded entirely we cannot authority Offenders will be liable for damages All rights guarantee full agreement However the data in this including rights created by
333. patent grant or registration of manual are reviewed regularly and any necessary a utility or design are reserved corrections included in subsequent editi ons Suggestions for improvement are welcome Technical data subject to change Copyright Siemens AG 1999 All Rights Reserved Note We would point out that the contents of this product documentation shall not become a part of or modify any prior or existing agree ment commitment or legal relationship The Purchase Agreement contains the complete and exclusive obligations of Siemens Any statements contained in this documentation do not create new warranties or restrict the existing warranty We would further point out that for reasons of clarity these operating instructions cannot deal with every possible problem arising from the use of this device Should you require further information or if any special problems arise which are not sufficiently dealt with in the operating instructions please contact your local Siemens representative WARNING The tools described in these instructions are intended only for stripping the jackets from SIMATIC NET PROFIBUS Plastic Fiber Optic cables Using the tools for any other purpose can lead to injury or to damage of the tools or cable Under no circumstances must the tools be used on live cables Personnel qualification requirements Qualified personnel as referred to in the operating instructions or in the warning notes are defined as pe
334. per l impiego all interno di edifici Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 1 3 Conduttore interno in rame massiccio Protezione di isolamento FC Food Cable cavo di bus con guaina esterna in PE Guaina esterna in PE Schermo a maglia in rame Foglio di schermatura in alluminio Foglio in materiale sintetico in PE cellulato Materiale di riempimento Figura 4 3 Principio di struttura del cavo di bus con guaina esterna in PE Cavo di bus FC con guaina esterna in PE 6XV1 830 0GH10 Propriet Impiego Il cavo di bus FC con guaina eserna in PE 6XV1 830 0GH10 corrisponde alla spe cifica secondo EN 50170 tipo di cavo A con conduttori in rame massiccio AWG 22 La struttura interna del cavo conduttori materiale di riempimento schermaggio identica a quella del cavo di bus standard La struttura del cavo permette l impiego delFastConnect FC Stripping Tool per lo spostamento rapido del cavo PROFIBUS vedere capitolo 4 2 3 Rispetto al cavo di bus standard la guaina esterna di polietilene PE presenta le seguenti propriet e una maggiore resistenza allo sfregamento e maggiore resistenza a olio e lubrificante e resistenza a radiazioni UV e resistente ad acqua e vapore e il materiale della guaina esterna infiammabile Il cavo di bus con guaina in PE particolarmente adatto per l impiego nell industria alimentare e dolcia
335. pliTConnect System Mounting Instruction for SIMATIC NET PROFIBUS SpliTConnect System Typ Type Beschreibung Description Bestell Nummer Ord code SpliTConnect Terminator SpliTConnect Terminator Ex Bussegments Zum elektrischen Abschlu eines 6GK1905 0AE00 6GK1905 0AD00 For electrical termination of a bus segment Montage Mounting SpliTConnect Terminator Ex 10 in SpliTConnect Tap 1 einf hren Ausrichtung ist durch Nut N und F hrung im SpliTConnect Terminator Ex 10 vorge geben Achtung Alle 3 Abg nge m ssen korrekt best ckt sein SpliTConnect Terminator Ex 10 bis auf Anschlag anziehen Zur Unterst tzung kann ein Schrauben dreher durch die daf r vorgesehene ffnung im SpliTConnect Terminator Ex 10 gesteckt werden Insert SpliTConnect Terminator Ex 10 into SpliT Connect Tap 1 Alignment is given by groove N and slot in the SpliTConnect Terminator Ex 10 Attention All 3 ports have to be mountet correctly Tighten SpliTConnect Terminator Ex 10 as much as possible For supporting this a screw driver can be used by inserting in the provided hole of the contacting element 2 SpliTConnect Terminator Ex Zum Einsatz in For use in Il 1G EEx ia IIC T6 amp Zert Nr Cert No DMT 99 ATEX E 054 Tumax 20 C 50 C 15 V 128 mA U max max Parameter gem EN 50020 FISCO Modell Parameter according EN 50020 FISCO model
336. pp2 PROFIBUS PROFIBUS DP 1 py DP DP COUPLER Figura 2 13 Accoppiatore DP DP Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 19 Topologie delle reti SIMATIC NET PROFIBUS Struttura L accoppiatore DP DP integrato in un contenitore compatto largo 40 mm Questo accoppiatore pu essere installato in linea senza distanza preferibilmente in posizione verticale su una guida profilata a norma L allacciamento dell accoppiatore alle reti PROFIBUS DP viene eseguito rispettiva mente tramite un connettore Sub D a 9 poli integrato Master OP 25 DP DP COU Master PG PC OP Resistenze terminali attivate 2 cavo di bus PROFIBUS Figura 2 14 Esempio di configurazione per accoppiatore DP DP Tipo di funzionamento L accoppiatore DP DP copia in permanenza i dati di uscita di una rete sui dati di ingresso dell altra rete e viceversa Parametrizzazione Gli indirizzi PROFIBUS DP vengono impostati tramite due interruttori DIP sul lato superiore dell apparecchio La progettazione viene eseguita tramite il file GSD con il tool di progettazione del master PROFIBUS DP rispettivamente allacciato La lunghezza dei dati viene impostata sempre con il rispettivo tool di progettazione Reti PROFIBUS SIMATIC NET 2 20
337. ptical axis ILM 2m 4m 10 degrees aperture angle la 12m 4 15m gt Figure 19 Transmitter Illumination of the PROFIBUS ILM Copyright by Siemens 50 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 12 Appendix Electrical parameters of the RS 485 LAN cables You can use the following cables to attach an RS 485 bus segment and individual DTEs to the PROFIBUS ILM gt Cable Type A complying with PROFIBUS DP DIN 19 245 Part 2 gt Cable Type B complying with DIN 19 245 Part 1 04 91 Section 3 1 2 3 Remember the restricted distance and transmission rate possible with the Type B cable according to Table 2 Cable Parameters Characteristic resistance 135 to 165 ohms 100 to 130 ohms 3 to 20 MHz f 100 kHz Capacitance per unit lt 30 pF m lt 60 pF m length Loop resistance lt 110 Ohms km Core cross section Table 5 Electrical Parameters of the Shielded Twisted Pair LAN Cables 51 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 13 References gt PROFIBUS networks SIEMENS AG gt DIN 19245 Part 1 04 91 Messen Steuern Regeln PROFIBUS Teil 1 Process Field Bus bertragungstechnik gt DIN 19245 Teil 2 10 91 Messen Steuern Regeln PROFIBUS Teil 3 Process Field Bus Dezentrale Peripherie DP gt EIA Standard RS 485 April 1983 Standard for electrical characteristics of generators and receiv
338. queste parti ad una massa uniforme del sistema crea un unico potenziale di riferimento per l impianto e riduce l effetto di disturbi accoppiato Informazioni dettagliate per il collegamento a massa nell ambito di una struttura dell impianto sono riportate nei manuali di sistema dei controllori programmabili SIMATIC S7 300 11 e S7 400 12 Trattamento degli schermi per cavi di bus elettrici Definizione Lo schermaggio un provvedimento per indebolire attenuare campi di disturbo magnetici elettrici o elettromagnetici Le correnti di disturbo sugli schermi dei cavi devono essere condotte con collega menti a terra corti con buona conduzione e su ampia superficie Per evitare che queste correnti di disturbo arrivino in un apparecchio o in un armadio di comando necessario eseguire questa deviazione direttamente prima o all ingresso nel con tenitore dell apparecchio dell armadio di comando Misure per lo schermaggio dei cavi C 8 Per lo schermaggio dei cavi osservare le seguenti misure e Utilizzzare solo cavi SIMATIC NET PROFIBUS Gli schermi di questi cavi ga rantiscono una tenuta sufficiente del rivestimento dello schermo conforme mente ai requisiti di legge relative all emissione e all immissione di disturbi e Applicare gli schermi dei cavi di bus sempre su entrambi i lati Solo allacciando gli schermi su entrambi i lati si ottengono i requisiti richiesti per legge relativi all emissione e all immissione di distur
339. r la realizzazione di una rete ottica PROFIBUS con nodi PRO FIBUS che dispongono di interfaccia FO integrata sono riportate anche nel ma nuale di sistema ET200 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 5 Topologie delle reti SIMATIC NET PROFIBUS 2 2 1 Topologia con interfacce ottiche integrate La rete ottica PROFIBUS con nodi che dispongono di un interfaccia FO integrata viene realizzata con topologia lineare nodi PROFIBUS sono collegati tra loro in coppia con cavi in fibra ottica duplex In una rete ottica PROFIBUS possono essere attivati in linea fino a 32 nodi PRO FIBUS con interfaccia FO integrata Se un nodo PROFIBUS si guasta a causa della topologia lineare il master DP non pu pi accedere a tutti gli altri slave DP successivi S7 400 con IM 467 FO ET 200M con PG PC OP IM 153 2 FO OBT Lunghezze tracciato tra 2 nodi FO di plastica fino a 50 m FO di PCF fino a 300 m Resistenza terminale attivata nodi Figura 2 2 1 cavo in fibra ottica 2 cavo di bus PROFIBUS Rete PROFIBUS DP con nodi dotati di interfacce FO integrate Per brevi distanze in alternativa al cavo PROFIBUS possono essere impiegati cavi di connessione 830 1T o 830 2 preconfezionati Velocit di trasmissione Per il funzionamento della rete ottica PROFIBUS con topologia lineare
340. r their work e g B gt Training in or authorization for connecting up grounding or labeling circuits and devices or systems in accordance with current standards in safety technology gt Training in or authorization for the maintenance and use of suitable safety equipment in accordance with current standards in safety technology gt First Aid qualification Copyright by Siemens 2 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 5 1 5 2 5 2 1 5 2 2 5 3 5 4 5 5 5 6 5 6 1 5 6 2 6 1 6 2 6 3 6 4 7 1 7 2 8 1 8 2 The Product Symbols Introduction Description of the Device Description of the Functions Transmission Rate Topologies Point to Point Link Point to Multipoint Link Signal Regeneration Monitoring the Received Optical Level Constant Light Monitoring Monitoring the Optical Link Monitoring the Optical Receive Activity Monitoring the Optical Link with an Acknowledgment Pulse Modes and Settings Setting the Terminating Resistor Setting the Transmission Rate Operation With Acknowledgment Pulse Operation with Signaling Contact Installation and Startup Notes on Safety General Notes on Installation and Startup Installing the PROFIBUS ILM Connecting the Electrical RS 485 Bus Cables Connecting the Power Supply and the Signaling Contact Displays Copyright by Siemens wo NIIN PMP MPM INI IN D PO PPO a a et in Sle BRB BERNER BBS a la l ERREG EE oo a m
341. rally more susceptible to problems than transmission via cable optical or electric 11 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 amp Make sure that the infrared link cannot be disturbed for example by interrupting the link with obstacles extraneous light etc When cascading with PROFIBUS ILM only one segment with master nodes is permitted the cascaded segments must only contain slave nodes 57 Make sure that the two infrared transmission links do not interfere with each other in other words either the spatial arrangement of the modules clearance or a physical barrier wall must ensure that each PROFIBUS ILM can only detect the transmission of its partner module and cannot detect emissions from either of the modules of the other infrared link Note When cascading the delay times of the PROFIBUS ILMs must be taken into account The delay times are shown in Table 3 and must be included in the calculations during configuration Copyright by Siemens 12 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Infrared transmission link 1 PROFIBUS 0 5to 15m master network segment w a PROFIBUS slave network segment 1 Optical isolation between the transmission links E Infrared transmission link 2 0 5 to 15m
342. rammazione PG PC Operator Panel OP o nodi senza interfaccia ottica integrata p es ET 200B oppure componenti DP di altri produttori e Due interfacce ottiche per l allacciamento di cavi in fibra ottica di plastica e di PCF con connettori simplex collegamento a CP 342 5 FO IM 467 FO o a ET 200 con interfaccia ottica integrata e Alimentazione 24 V DC Funzioni Collegamento di un segmento PROFIBUS RS 485 Predisposizione di un punto di allacciamento elettrico al PROFIBUS ottico p es allacciamento PG per la messa in funzione e la diagnostica Supporto di tutte le velocit di trasmissione PROFIBUS da 9 6 kbit s a 1 5 Mbit s e 12 Mbit s Rigenerazione dei segnali in ampiezza e tempo Profondit di cascata per l utilizzo di parametri di bus con definizione utente fino a 126 nodi Separazione di potenziale del nodo DP tramite cavo in fibra ottica Semplice diagnostica tramite indicatore LED per la tensione d esercizio e per la ricezione dei dati CH1 CH2 e CH3 Dati per l ordinazione N di ordinazione PROFIBUS OBT Bus terminal ottico per l allacciamento di un segmento PROFIBUS RS 485 ad una linea ottica senza connettore simplex 6GK1 500 3AA00 Istruzioni per l uso Le istruzioni per l uso complete del bus terminal ottico OBT si trovano nell appen dice del presente manuale 2 Ulteriori informazioni sono riportate nel catalogo PROFIBUS amp AS Interface Reti PROFIBUS SIMATIC_NET 6GK1970 5C
343. rammi Il tempo a sua disposizione preimpostato dal cosiddetto tempo di arresto del token Se questo tempo scaduto il nodo pu trasmettere solo an cora un messaggio di massima priorit Se il nodo non deve trasmettere nessun messaggio esso passa il token direttamente al nodo successivo nell anello lo gico timer del token interessati dai quali viene calcolato il tempo massimo di arresto del token vengono progettati per tutti i nodi attivi Se un nodo attivo dispone del token e se per esso sono progettati collegamenti a nodi passivi collegamenti master slave questi ultimi vengono interrogati p es lettura dei valori o ad essi vengono trasmessi dei dati p es impostazione del valore nominale nodi passivi non ricevono mai il token Il metodo di accesso permette di inserire e togliere nodi durante il funzionamento 1 2 3 Metodo trasmissivo A seconda del mezzo utilizzato per SIMATIC NET PROFIBUS vengono impiegati RS 485 per reti elettriche sulla base di cavi schermati a due coduttori intrecciati metodo ottico secodo la direttiva PNO 3 sulla base di cavi in fibra ottica metodo senza fili sulla base di raggi infrarossi tecnica IEC 61158 2 e reti elettriche a sicurezza intrinseca e non a sicurezza intrinseca con tecnica di procedimento PROFIBUS PA sulla base di cavi schermati a due conduttori intrecciati Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 1 9 RETI PROFIBUS 1 2 4 Metodo t
344. rasmissione ottici Il fascio di luche che fuoriesce pu danneggiare gli occhi N Pericolo di morte Non allacciare mai PROFIBUS OBT alla tensione di rete di 110 V 240 V Avvertenza Scegliere la posizione di montaggio in modo da rispettare i valori limite climatici riportati nei dati tecnici PROFIBUS Optical Busterminal OBT 5 1 C79000 G8972 C1 22 02 Messa in funzione 5 1 5 2 Avvertenza Il canale RS485 CH1 di PROFIBUS OBT presenta separazione di potenziale dall ingresso di 24V Si tratta di una separazione in base alla funzione e non di una separazione di sicurezza Avvertenza Provvedere ad una messa a terra sufficiente di PROFIBUS OBT collegando la guida ad U o la piastra di montaggio alla terra locale a bassa resistenza e a bassa induttanza Avvertenza Come cavo di bus RS 485 utilizzare solo cavi di bus approvati per PROFIBUS Avvertenza Il contenitore dell OBT non deve essere aperto Procedimento per la messa in funzione La messa in funzione di PROFIBUS OBT viene eseguita con le seguenti opera zioni e Montaggio di PROFIBUS OBT e Allacciamento della tensione di alimentazione e Allacciamento dei cavi di bus ottici e Allacciamento del cavo di bus elettrico RS 485 PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Messa in funzione 5 2 Installazione Montaggio di PROFIBUS OBT PROFIBUS OBT possono essere montati su una guida ad
345. rasmissivo in base allo standard EIA RS 485 Standard EIA RS 485 Il metodo trasmissivo RS 485 corrisponde alla trasmissione dei dati simmetrica in base allo standard EIA RS 485 4 Questo metodo trasmissivo prescritto nella norma PROFIBUS EN 50170 per la trasmissione dei dati su cavi a due conduttori Il mezzo trasmissivo un cavo schermato a due conduttori intrecciati Il cavo di bus viene chiuso su entrambe le estremit con una impedenza caratteri stica Un cavo di bus chiuso in questo modo viene chiamato segmento L allacciamento dei nodi al bus viene eseguito con un bus terminal con cavo di derivazione o un connettore di bus max 32 nodi per ogni segmento singoli segmenti vengono collegati tramite un repeater La lunghezza massima di un segmento dipende e dalla velocit di trasmissione e dal tipo di cavo impiegato Vantaggi e Struttura lineare o ad albero flessibile con repeater bus terminal e connettori di bus per l allacciamento del nodo PROFIBUS e l inoltro del segnale passivo permette la disattivazione del nodo senza effetti sulla rete ad eccezione di nodi che forniscono resistenze terminali e semplice installazione del cavo di bus senza conoscenze specifiche Reti PROFIBUS SIMATIC NET 1 10 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS Limitazioni e Aumentandola velocit di trasmissione viene ridotta lunghezza realizzabile della linea e In caso di posa all aperto sono necessarie misu
346. rating mode if you optically connect PROFIBUS OLMs of the same version The operating mode Redundant optical ring must be set at both optical ports of all the PROFIBUS OLM All modules in a ring must be connected to one another by fiber lines The ring may not include an RS 485 bus line The parameter MIN Tspr described in the PROFIBUS standard EN 50170 must be set to a value 11 on all terminals This is usually the case but the setting should be checked if communication malfunctions continuously arise When configuring your network select low bus subscriber addresses wherever possible This ensures that master timeout times which may arise are kept as short as possible in the event of a malfunction If a redundancy case occurs e g a line break there is a switching time during which data cannot be correctly transmitted In order to ensure a smooth transition it is recommended that the frame repeat setting Retry on the PROFIBUS master be set to at least 3 After the error has been corrected no frames should be present in the network when the optical line is trans formed back into an optical ring to ensure that the process is completed smoothly This condition can arise when a master selects a device whose address has been configured but which does not physically exist The master tries to address this device cyclically and waits for a reply only until the configured slot time has been exceeded GAP request The OLM recog
347. rd Fiber Optic e cavo universale per l impiego all interno di edifici e all aperto Cavo per l impiego in edifici INDOOR Fiber Optic e cavo in fibra ottica esente da alogeni calpestabile e difficilmente infiammabile per l impiego all interno di edifici Cavo da trascinamento flessibile Fiber Optic e per l impiego specifico p es parti in movimento forzato Cavo marino in fibra ottica duplex SIENOPYR e cavo ibrido composto da 2 cavi in fibra ottica e 2 conduttori supplementari in rame per l installazione fissa su navi e unit offshore Fibre standard SIMATIC NET Per i cavi in fibra ottica di vertro SIMATIC NET utilizza come standard una fibra con diametro del nucleo di 62 5 um L ottimale compatibilit dei componenti di bus SIMATIC NET con queste fibre standard consente di realizzare maggiori lun ghezze della linea semplificando le regole di progettazione Semplice progettazione In tutte le descrizioni e istruzioni per l uso dei componenti di bus SIMATIC NET sono riportate le specificazioni relative alle lunghezze di linea realizzabili con le fibre standard riportate sopra In questo modo possibile progettare una rete ottica senza calcoli complicati con l aiuto dei valori limite vedere capitolo 3 Progetta zione di reti Direttive di installazione Le avvertenze per la posa dei cavi in fibra ottica di vetro SIMATIC NET sono ripor tate nell appedice C del presente manuale Reti PROFIBUS SIMATI
348. re completamente sulla guida di metallo 4 Inserire i conduttori verdi e rossi nelle guide sui morsetti di perforazione in base alla figura 4 20 Durante questa operazione fare attenzione che vengano allacciati sempre gli stessi conduttori agli stessi allacciamenti A o B p es allacciamento A sempre con il filo verde e allacciamento B con il filo rosso 5 Premere leggermente con il pollice i conduttori rossi e verdi nei morsetti di per forazione 6 Riserrare le viti del coperchio Guide Morsetti di perfo razione Guide Scarico di tiro Figura 4 20 Collegamento del cavo di bus al connettore di bus 6ES7 972 0BA30 0XA0 Avvertenza Il connettore di bus 6ES7 972 0BA30 0XA0 non pu essere collegato a cavi di bus con conduttori a trefoli Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 41 Componenti passivi per reti RS 485 4 4 3 Collegamento del cavo di bus al connettore di bus 6ES7 972 0B 40 Aspetto 6ES7 972 0B 40 La figura 4 21 illustra il connettore di bus con il numero di ordinazione 6ES7 972 0B 40 Viti per il fissag ___ P Connettore D Sub a gio sulla sta 9 poli per il collega zione mento alla stazione D Presa PG solo per 6ES7 Viti del contenitore 972 0BB40 0XA0 Figura 4
349. re integrato a 4 poli elemento di allacciamento M12 AS Interface Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 29 Topologie delle reti SIMATIC NET PROFIBUS Settore d impiego La DP AS Interface Link collega il bus di campo PROFIBUS DP all AS Interface La DP AS Interface Link 65 pu essere allacciata ad ogni master PROFIBUS DP che pu elaborare telegrammi di parametrizzazione e di diagnostica lunghi 32 byte La DP AS Interface Link 65 permette di utilizzare l Aktor Sensor Interface come sotto rete per PROFIBUS DP In questo modo possibile combinare in modo ideale i vantaggi di PROFIBUS DP e di AS Interface in un unico sistema di bus Collegamento in rete sovraordinato tramite PROFIBUS DP 4 Alimentazione esterna i DC 24 V 8 DP AS Interface Link 65 O Moduli passivi Moduli attivi senza slave ASIC con slave ASIC dI tal Alimentazione AS i Aktor Sensor alata con slave ASIC TL Il A Su Cavo Diramazione AS i Figura 2 21 Esempio di configurazione per DP AS Interface Link 65 Tipo di funzionamento La DP AS Interface Link 65 collega PROFIBUS DP all AS Interface con classe di protezione IP 65 La DP AS Interface Link 65 pu essere allacciata ad ogni master PROFIBUS DP che trasmette telegrammi di parametrizzazione lunghi 32 byte Per agire come accoppiatore di bus tra i due sistemi di bus la DP AS Interface Link dispone per l AS Interface della funzionalit di
350. re supplementari di protezione contro i fulmini Propriet della tecnica trasmissiva RS 485 La tecnica trasmissiva RS 485 per PROFIBUS dispone delle seguenti propriet fisiche Tabella 1 1 Propriet fisiche della tecnica trasmissiva RS 485 Topologia della rete Lineare struttura ad albero in caso di impiego di repeater Cavo schermato a due conduttori intrecciati Lunghezze di segmento re 1 000 m per velocit di trasmissione fino a 187 5 kbit s alizzabili 400 m per velocit di trasmissione di 500 kbit s in base al tipo di cavo ve 200 m per velocit di trasmissione di 1 5 Mbit s dere tabella 3 1 100m per velocit di trasmissione 3 6 e 12 Mbit s Numero di repeater attivabili max 9 in linea Numero dei nodi max 32 su un segmento di bus max 127 per ogni rete utilizzando repeater Velocit di trasmissione 9 6 kbit s 19 2 kbit s 45 45 kbit s 93 75 kbit s 187 5 kbit s 500 kbit s 1 5 Mbit s 3 Mbit s 6 Mbit s 12 Mbit s Avvertenza Per le propriet riportante nella tabella 1 1 necessario un cavo di bus del tipo A e un terminale di bus conforme alla norma PROFIBUS EN 50170 1 2 cavi SIMA TIC NET PROFIBUS e i connettori di bus corrispondono a questa specifica In caso di versioni speciali di cavi di bus con una resistenza del conduttore maggiore consultare i capitoli Progettazione e Cavi SIMATIC NET PROFIBUS dove si trovano istruzioni per accorciare eventualmente le lunghezze di segmento i
351. receive level RX LED also not lit Data optically received the level is however low RX LED also lit risk of data errors red LED not lit Infrared level at receiver is not critical Infrared level at receiver is critical risk of data errors Copyright by Siemens 40 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 10 Help With Problems During Operation 10 1 Status Displays for Incorrect Operation LED Display Possible Causes ng ontact POWER LED Power supply failed or turned off Always si Module defective gnals Ribbon band cable not plugged in when assem bling the module POWER LED lit green Interruption on one or more cores of the RS 485 LAN cable Reversed connection of core A and B of the RS 485 LAN cable Connected PROFIBUS master defective not sen ding PROFIBUS node is not attached or attached PROFIBUS node is not turned on No partner station detected with attached PROFI BUS master TX LED not lit RX LED not lit POWER LED lit green Interruption on one or more cores of the RS 485 LAN cable TX LED not lit Reversed connection of core A and B of the RS 485 LAN cable Attached PROFIBUS slave defective not sen ding PROFIBUS slave is not attached or attached PROFIBUS slave is not turned on PROFIBUS slave node not correctly addressed and therefore not responding RX LED lit yellow POWER LED lit green No acknowledgment pulse received partner sta Signals when tion not responding configure
352. relationship The Purchase Agreement contains the complete and exclusive obligations of Siemens Any statements contained in this documentation do not create new warranties or restrict the existing warranty We would further point out that for reasons of clarity these operating instructions cannot deal with every possible problem arising from the use of this device Should you require further information or if any special problems arise which are not sufficiently dealt with in the operating instructions please contact your local Siemens representative General This device is electrically operated Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions WARNING Failure to heed warnings may result in serious physical injury and or material damage Only appropriately qualified personnel may operate this equipment or work in its vicinity Personnel must be thoroughly familiar with all warnings and maintenance measures in accordance with these operating instructions Correct and safe operation of this equipment requires proper transport storage and assembly as well as careful operator control and maintenance Personnel qualification requirements Qualified personnel as referred to in the operating instructions or warning notes are defined as persons who are familiar with the installation startup and operation of this product and who possess the relevant qualifications fo
353. repeater RS 485 rinforza i segnali dei dati sui cavi di bus e collega i segmenti di bus Impiego del repeater RS 485 6ES7 972 0AA01 0XA0 Il repater RS 485 necessario se e al bus sono allacciate pi di 32 stazioni compreso il repeater e sul bus devono essere utilizzati segmenti di bus senza collegamento a terra oppure e viene superata la lunghezza massima di un segmento vedere capitolo 3 Pro gettazione della rete Regole Se si realizza una rete PROFIBUS con repeater RS 485 possono essere collegati in serie al massimo nove RS 485 Realizzazione del repeater RS 485 La tabella 5 1 illustra la struttura del repeater RS 485 Reti PROFIBUS SIMATIC NET 5 2 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 Tabella 5 1 Descrizione e funzioni del repeater RS 485 Funzione Allacciamento per l alimentazione del repeater RS 485 il pin M5 2 la massa di riferimento se si intende misurare il pas saggio di tensione tra gli allacciamenti A2 e B2 Fascetta di schermatura per lo scarico di tiro e il collegamento a terra del cavo di bus del segmento 1 0 2 Allacciamento per il cavo di bus del segmento 1 Resistenza terminale per il segmento di bus 11 Interruttore per stato di funzionamento OFF scollegare i segmenti di bus 1 e 2 p es per la messa in funzione Resistenza
354. ria Esso concepito per l installazione fissa all interno di edifici cablaggio In house Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 9 Componenti passivi per reti RS 485 4 1 4 Conduttore interno in rame massiccio Protezione di isolamento FC Robust Cable cavo di bus con guaina esterna in PUR Guaina esterna in PUR Schermo a maglia in rame Foglio di schermatura in alluminio Foglio in materiale sintetico in PE cellulato Materiale di riempimento Figura 4 4 Principio di struttura del cavo di bus con guaina esterna in PUR Cavo di bus FC con guaina esterna in PUR 6XV1 830 0JH10 Propriet Impiego 4 10 Il cavo di bus FC con guaina esterna in PUR 6XV1 830 0JH10 corrisponde alla specifica secondo EN 50170 tipo di cavo A con conduttori in rame massiccio AWG 22 La struttura interna del cavo conduttori materiale di riempimento schermaggio identica a quella del cavo di bus standard La struttura del cavo permette l impiego del FastConnect FC Stripping Tool per lo spostamento rapido del cavo vedere capitolo 4 2 3 Rispetto al cavo di bus standard il materiale della guaina esterna PUR presenta le seguenti propriet e una maggiore resistenza allo sfregamento e maggiore resistenza a olio e lubrificante e resistenza a radiazioni UV e il materiale della guaina esterna resistente alla fiamma Il cavo di bus con guaina in PUR particolarmente adatto per amb
355. ridurre di conseguenza i tempi di fermo dell impianto Avvertenza Controllare la fisica del bus prima della messa in funzione con il BT200 tempi per la messa in funzione possono cos essere ridotti in modo da evitare tempi di fermo dell impianto o guasti sporadici del bus Funzioni di protocollo Tutti i risultati dei test possono essere memorizzati nel BT200 Un cavo punto a punto consente di trasmessere i dati sul un PC risultati dei test vengono preparati nel PC in un formato di protocollo e possono anche essere stampati In questo modo possibile creare un protocollo di collaudo per la documentazione Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 TECNICA DI MISURA PROFIBUS A 1 4 Struttura Figura A 1 Dispositivo di test hardware BT 200 per PROFIBUS DP e Contenitore compatto di plastica in IP30 e Dimensioni LxAxP in mm ca 210 x 100 x 50 e Diplay LCD con 2x16 caratteri e Tastiera a membrana con 8 tasti e Allacciamento alla rete PROFIBUS tramite connettore femmina Sub D a 9 poli e Aimentazione tramite accumulatore NC integrato e Allacciamento a caricabatteria accessorio Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 A 3 TECNICA DI MISURA PROFIBUS A 1 5 Funzioni Controllo della linea PROFIBUS Durante questa misurazione viene misurato unicamente il cavo PROFIBUS possibile identificare i seguenti guasti Cortocircuito tra cavi dati oppure ca
356. rise which are not sufficiently dealt with in the operating instructions please contact your local Siemens representative Personnel qualification requirements Qualified personnel as referred to in the operating instructions or in the warning notes are defined as persons who are familiar with the installation assembly startup and operation of this product and who possess the relevant qualifications for their work and have a First Aid qualification Page 2 SIMATIC NET PROFIBUS PCF Fiber Optic Standard Cable General Instructions for Working with SIMATIC NET PROFIBUS PCF Fiber Optic Cables Please note the following instructions to avoid damage to cables E Make sure that the selected cable is suitable for the area of application You should for example check the following Required temperature range Resistance of the jacket materials to chemicals water oils rodents etc to which the cable may be exposed in your application Required mechanical properties bending radii tensile strength transverse compressive strength Required behavior of the cable in fire Suitability of the cable including the connectors for the devices to be interconnected If necessary use a special cable that meets your requirements Your SIMATIC NET contact in your local Siemens branch will be happy to advise you Never exceed the maximum permitted loads tensile load transverse compressive load etc specified in the data sheet
357. rispettivamente di 20 cm con elemento ausiliario di inserimento montato su un lato per il collegamento di OLM P Lunghezze disponibili 6XV1821 1BN75 6XV1821 1BT10 6XV1821 1BT15 6XV1821 1BT20 6XV1821 1BT25 6XV1821 1BT30 6XV1821 1BT40 altre lunghezze su richiesta Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche Dati per l ordinazione cavi PCF Fiber Optic confezionati per le interfacce ottiche integrate SIMATIC NET PROFIBUS PCF Fiber Optic I VY2K 200 230 10A17 8B20 fibra ottica di PCF con 2 conduttori guaina esterna di PVC per realizzare grandi distanze fino a 300 m confezionato con 2x2 connettori simplex lunghezza dei conduttori che sporgono dalla guaina rispettivamente 30 cm con elemento ausiliario di inserimento montato su un lato per il collegamento di apparecchi con interfacce ottiche integrate OBT Lunghezze disponibili 50m 6XV1821 1CN50 75m 6XV1821 1CN75 100m 6XV1821 1CT10 150m 6XV1821 1CT15 200 m 6XV1821 1CT20 250 m 6XV1821 1CT25 300 m 6XV1821 1CT30 altre lunghezze su richiesta Reti PROFIBUS SIMATIC NET 7 12 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti ottiche 7 3 Cavo in fibra ottica di vetro Designed for Industry cavi in fibra ottica di vetro SIMATIC NET FO sono disponibili in diverse versioni permettendo cos un adattamento ottimale ai diversi settori di impiego Settore d impiego Cavo standa
358. rman Electrical Engineers 34 Version 1 1 8 00 8 Appendix 8 4 Measuring sockets 8 4 Measuring sockets Signal A quality good Normal operation critical Reduced optical system reserves poor 0 100 200 300 400 500 600 700 800 900 Output voltage mV Diagram 1 Assignment of measured output voltage to signal quality Notes In order to attain a valid reading it is necessary for the partner OLM at the other end of the optical fiber to send regular PROFIBUS frames This can be seen on the LED display of the partner OLM see 5 LED Indicators and Troubleshooting p 25 The output voltage at the measuring sockets is subject to many influencing factors such as the strength of the transmitting power of the partner OLM m the ambient temperature of the optical sender and receiver attenuation of the transmitting link the transfer rates being used The measuring sockets are therefore not intended as a substitute for a calibrated level measuring device with a calibrated light source The readings taken should only serve to classify the optical signal being received in the 3 classes good normal operation critical reduced optical system reserves poor function not guaranteed Measurements must be taken with a conventional ungrounded and high resistance voltmeter A connection to the OLM housing is not permitted either from the measuring sockets or the reference potential Version 1 1 8 00
359. ro tensioni di disturbo C 4 2 Montaggio e collegamento a terra delle parti metalliche inattive C 4 3 Trattamento degli schermi per cavi di bus elettrici C 4 4 Equipotenzialit c cect nennen C 5 Installazione di cavi di bus elettrici annn aa annn C 5 1 Categorie e distanze dei Cavi C 5 2 Installazione dei cavi all interno di armadi C 5 3 Installazione dei cavi all interno di edifici 2 0 0 0 00 cee eee eee C 5 4 Installazione dei cavi fuori da edifici 0 0 eee C 5 5 Provvedimenti speciali per l eliminazione di disturbi C 6 Compatibilit elettromagnetica dei cavi in fibra ottica C 7 Posadi cavi di DUS ese ta ceeded eke ied whee man C 7 1 Avvertenze per la posa di cavi di bus elettrici e ottici C 8 Ulteriori avvertenze per l installazione di cavi in fibra ottica Istruzioni di montaggio per SIMATIC NET PROFIBUS Plastic Fiber Optic con connettori simplex o connettori BFOC ed elemento ausiliare di inserimento per cavo standard Fiber Optic Installazione di componenti di rete in un armadio E 1 Grado di protezione IP_ eee E 2 Componenti SIMATIC NET Disegni in scala u em en aa F 1 Disegni in scala dei connettori di bus 0c e eee eee F 2 Disegni in scala del repeater RS 485 cee ee F
360. rogettato ma non esiste real mente Il master attende una risposta fino al trascorrere del tempo di slot progettato L OLM riconosce questa fase senza telegrammi e chiude la linea ottica in un anello ottico nel mezzo di questa sequenza di interrogazione Il tempo di slot deve essere impostato all incirca al valore doppio di quello neces sario per una rete non ridondante Calcolare il tempo di slot in base alla seguente equazione Tempo di slot a b x lunghezzapo c x numerooLM Tempo di slot il tempo di controllo in tempi di bit Lunghezza fo la somma di tutti i cavi FO lunghezza segmento nella rete La specificazione della lunghezza deve essere in km NumerooLM il numero di PROFIBUS OLM nella rete fattori a b e c dipendono dalla velocit di trasmissione e possono essere rilevati dalle tabelle 3 9 e 3 10 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti Tabella 3 9 Costanti per il calcolo del tempo di slot per standard DP anello ottico ridondante Velocit di a b c trasmissione 12 Mbit s 1651 240 28 6 Mbit s 951 120 24 3 Mbit s 551 60 24 1 5 Mbit s 351 30 24 500 kbit s 251 10 24 187 5 kbit s 171 3 75 24 93 75 kbit s 171 1 875 24 45 45 kbit s 851 0 909 24 19 2 kbit s 171 0 384 24 9 6 kbit s 171 0 192 24 Tabella 3 10 Costanti per il calcolo del tempo di slot per DP FMS Universale
361. rom the round cut Cut off remnants of the jacket Kevlar Standard cable with the outer jacket fibers and foil with scissors stripped Page 6 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors Separating the SIMATIC NET PLASTIC FIBER OPTIC Duplex Cord Insert a sharp knife 20 cm if fitting a plug Caution Separated duplex cords adapter 30 cm from the end of the cable Do not split the cords simply by hand in the groove between the two cords and since the fibers can easily be bent split the cords up to the end of the cable beyond the minimum bending radius Caution The buffer of the cords must not be damaged Page 7 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors Removing the Buffer To strip the buffer from the plastic fibers use the SIMATIC NET buffer stripper included in the stripping tool set Important note Use the opening labeled AWG 16 1 5 mm Smaller openings damage the fiber and must not be used Insert the cord into the opening labeled AWG 16 The cord must extend approximately 5 mm beyond the blade Open the handles of the stripper slowly until the clamp releases the cord Remove the cord from the stripper Only open the handles of the stripper completely after you have removed the cord Caution If the handles are opened completely before the cord has been removed t
362. rotezione completa contro il contatto protezione contro la penetrazione di polvere e protezione contro spruzzi d acqua provenienti da tutte le direzioni IP 66 Classe di protezione secondo DIN 40050 protezione completa contro il contatto protezione contro la penetrazione di polvere e protezione contro l infiltrazione di forti spruzzi d acqua IP 67 Classe di protezione secondo DIN 40050 protezione completa contro il contatto protezione contro la penetrazione di polvere e protezione contro la penetrazione di acqua con una determinata pressione in caso di immersione Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Glossar 3 Glossario ITP Industrial Twisted Pair adatto per l impiego industriale con funzione di sistema di bus sulla base degli standard Twisted Pair IEEE 802 3i 10BASE T e IEEE 802 3 100BASE T Massa Per massa si intende il complesso di tutti i componenti inattivi collegati di un mezzo d esercizio che non possono assorbire tensioni di contatto pericolose an che in caso di guasto Master possono trasmettere dati ad un altro nodo o ricevere dati da un altro nodo nodo attivo solo se in possesso del token max retry limit Max retry limit un parametro di bus e rappresenta il numero massimo di ripeti zioni di richiamo su uno slave DP max_Tspr Max_Tspr un parametro di bus e rappresenta il tempo massimo per l elabora zione del protocollo del nodo che risponde Station Del
363. rsons who are familiar with the installation assembly startup and operation of this product and who possess the relevant qualifications for their work and have a First Aid qualification Page 2 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors General Instructions for Working with SIMATIC NET PROFIBUS Plastic Fiber Optic Cables Please note the following instructions to avoid damage to cables E Make sure that the selected cable is suitable for the area of application You should for example check the following Required temperature range Resistance of the jacket materials to chemicals water oils rodents etc to which the cable may be exposed in your application Required mechanical properties bending radii tensile strength transverse compressive strength Required behavior of the cable in fire Suitability of the cable including the connectors for the devices to be interconnected If necessary use a special cable that meets your requirements Your SIMATIC NET contact in your local Siemens branch will be happy to advise you Never exceed the maximum permitted loads tensile load transverse compressive load etc specified in the data sheet of the cable you are using Excessive transverse compressive load can for example result from using screw clamps to secure the cable Only use plastic fiber optic cables with devices approved for this plastic FO cable Keep
364. rst rung des SpliTConnect Systems und der Leitung kommen Die Montage von Komponenten des SpliTConnect Tap Systems darf nur an Bussegmenten erfolgen die nicht in Betrieb sind Anforderung an die Qualifikation des Personals Qualifiziertes Personal im Sinne dieser Betriebsanleitung bzw der Warnhinweise sind Personen die mit Aufstellung Montage Inbetriebsetzung und Betrieb dieses Produktes vertraut sind und ber die ihrer T tigkeit entsprechenden Qualifikation verf gen und in erster Hilfe geschult sind We have checked the contents of this manual for agreement with this SpliTConnect System described Since deviations cannot be precluded entirely we cannot guarantee full agree ment However the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions Suggestions for improvement are welcome Technical data subject to change Note We would point out that the contents of this product documen tation shall not become a part of or modify any prior or existing agreement commitment or legal relationship The Purchase Agreement contains the complete and exclusive obligations of Siemens Any statements contained in this documentation do not create new warranties or restrict the existing warranty WARNING The reproduction transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights includ
365. ry out the measures described above Fault indicated on CH2 CH3 1 Check the following optically only modules of the same type are connected together see 3 Network topologies p 9 the optical fiber has been approved for the module type being used and that it does not exceed the permitted length see Table 1 p 6 the optical ports which are connected via optical fibers have been set to the same operating mode see 4 3 Setting compatibility operating mode and transmitting power p 17 the settings given in 4 4 1 Connecting the optical lines p 20 have been observed when connecting and laying the optical bus lines Version 1 1 8 00 27 5 LED Indicators and Troubleshooting 5 2 Troubleshooting 2 Define the optical receiving level see 4 4 6 Defining the receiving level of the optical ports p 24 and 8 4 Measuring sockets p 35 Level is in the range Function is not guaranteed Check the optical fiber absorption using an optical level measuring device too high replace the optical fiber in valid range one of the two OLMs of the disturbed optical fiber segments is defective First replace the other OLM of the disturbed optical fiber segments i e the OLM which supplies the send signal for the measurement described above If the fault still persists replace the other OLM instead Level is in the range Optical system reserves reduced or Normal mode As described a
366. s are physically related to the speed of light and certain material characteristics and are therefore almost constant approximately 5 us km First calculate the transmission link with the longest propagation time between the sender and receiver of a frame PROFIBUS nodes that communicate with each other for example DP slave with DP slave do not need to be taken into account Indicators for long propagation times are as follows gt Long fiber optic or copper cables gt High cascading depth of active components PROFIBUS OLMs PROFIBUS ILMs PROFIBUS repeaters The delay time is approximately 5 us per km cable length Copyright by Siemens 44 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM Converted to bit times this results in the following Transmission Rate Delay Time in Kbps in bit times per km 0 05 9 6 Table 2 Delay Times of Fiber Optic and RS 485 LAN Cables To calculate the cable delay time the maximum cable length in km is multiplied by the delay time corresponding to the transmission rate from the table 10 2 2 Delay Time of the PROFIBUS ILM In contrast to the propagation time of electrical cables and fiber optic cables the delay time through the logic of the PROFIBUS ILM clocked at the transmission frequency is not a physical time constant but depends on the transmission rate The number of logic levels in series is relevant with each causing a bit time delay The delay time per PROFIBUS ILM is 6 b
367. sattivata ON ON E d Figura 5 2 Posizione della resistenza terminale Reti PROFIBUS SIMATIC NET 5 6 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 Segmenti 1 e 2 chiusi La figura 5 3 illustra come collegare il repeater RS 485 alle estremit tra due seg menti Segmento 1 Segmento 1 Resistenza terminale Ce re re Segmento di bus 1 e attivazione 6 DO eeee Segmento 2 a E E si O An g 6 Resistenza terminale Segmento di bus 2 attivazione Segmento 2 Figura 5 3 Allacciamento di due elementi di bus al repeater RS 485 Segmento 1 chiuso segmento 2 passante La figura 5 4 illustra l accoppiamento di due segmenti con un repeater RS 485 nel quale un segmento passante Segmento 1 Segmento 1 Resistenza terminale Ce re re Segmento di bus 1 771 attivazione eeee gt C Segmento 2 22 e Em RN Rs 5 Resistenza terminale Segmento di bus 2 non attivare Segmento 2 Figura 5 4 Allacciamento di due elementi di bus al repeater RS 485 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 5 7 Componenti attivi per reti RS485 Segmenti 1 e 2 passanti La figura 5 5 illustra l accoppiamento di due segmenti co
368. se in environments where it is subjected to little mechanical stress for example within a cubicle or in a laboratory 50 m Ring 6XV1 821 2AN50 SIMATIC NET PROFIBUS Plastic Fiber Optic Stripping Tool Set Cable knife for removing the outer jacket and buffer stripper round cutting pliers for removing the buffer of SIMATIC NET PROFIBUS plastic fiber optic cables 6GK1 905 6PA10 SIMATIC NET PROFIBUS Plastic Fiber Optic BFOC crimping tool For fitting BFOC connectors to PROFIBUS Plastic Fiber Optic cables 6GK1 905 6PB00 SIMATIC NET PROFIBUS Plastic Fiber Optic BFOC connector set pack of 20 BFOC connectors for assembly of PROFIBUS Plastic Fiber Optic cables for OLM P 6GK1 905 1PA00 SIMATIC NET PROFIBUS Plastic Fiber Optic BFOC polishing set Polshing set for grinding and polishing the end face of the BFOC connector for PROFIBUS Plastic Fiber Optic cables OLM P 6GK1 905 6PS00 Installation Instructions for BFOC Connectors SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors Other commercially available accessories e Sharp scissors for shortening the Kevlar and the fibers e Sharp knife for separating the duplex cords e Clean soft cloth for cleaning the polishing discs and the connector end face Page 12 SIMATIC NET PROFIBUS PCF Fiber Optic SIEMENS SIMATIC NET Product Information How to Use the Pulling Loop for the SIMATIC NET PROFIBUS PCF Fiber Optic Standard
369. seguenti propriet e esente da alogeni e resistenza collaudata secondo VG 95 218 parte 2 contro carburante Diesel olio ASTM liquido idraulico detergente a freddo acqua deionizzata e resistenza a ozono secondo DIN VDE 0472 parte 805 tipo di prova B e comportamento alla combustione secondo DIN VDE 0472 parte 804 tipo di prova C e corrosivit dei gas di combustione secondo DIN VDE 0472 parte 813 corri sponde a IEC 60754 2 collaudato dall industria navale Germanischer Lloyd Lloyd s Register Registro Italiano Navale Reti PROFIBUS SIMATIC NET 4 22 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 Impiego Il cavo marino SIENOPYR FR previsto per l installazione fissa su navi e unit off shore in tutti i locali e all aperto Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 23 Componenti passivi per reti RS 485 4 2 Impiego 4 2 1 Connettore di bus FastConnect Con l aiuto del connettore di bus per SIMATIC NET PROFIBUS possibile e collegare i nodi con un interfaccia Sub D elettrica a 9 poli secondo EN 50170 direttamente ai cavi SIMATIC NET PROFIBUS e allacciare segmenti elettrici o nodi singoli a Optical Link Module OLM OBT allacciare nodi o PG al repeater Avvertenza terminali di bus e i dati meccanici del connettore di bus SIMATIC NET sono con formi ai cavi SIMATIC NET PROFIBUS tipo di cavo A della norma PROFIBUS EN
370. send activity can also be recognized with short data fields gt If an acknowledgment is received for a sent frame and the monitor link with acknowledgment pulse configuration is set the TX LED is lit yellow gt If no acknowledgment is received and the monitor link with acknowledgment pulse configuration is set the TX LED changes color from yellow to orange The pulse for this display is also extended to 300 ms so that a lost acknowledgment can also be recognized by the user The user can also configure a switch to activate a signaling contact The signaling contact remains inactive unless the monitor link with acknowledgment pulse configuration was set Copyright by Siemens 20 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 6 Modes and Settings To operate the PROFIBUS ILM the terminating resistor the data rate and the monitoring options must be set manually Note When shipped the configuration is as follows gt The terminating resistor is inactive gt The data rate is set to 1 5 Mbps gt The monitor link with acknowledgment pulse monitoring mechanism is inactive gt The activation of the signaling contact is disabled The settings can be made after removing the cover from the basic module using switches S201 transmission rate and monitoring mechanisms and S202 terminating resistor Terminating resistor switch Configuration switch S201 ON OFF
371. sima di percorso 10 dB km La lunghezza di percorso specificata tra i dispositivi presuppone che i dispositivi partner impieghino gli stessi componenti ottici dell OBT Questa il caso p es di IM 153 2 FO IM 467 FO e OLM12M La velocit di trasmissione non dipende in questo caso dal tipo di fibra impiegato e della lunghezza del cavo Essa pu essere di max 12 Mbit s Come accessori sono disponibili e FO in plastica a metraggio set di connettori di lucidatura e attrezzo di montag gio per cavi a fibre ottiche in plastica cavi a fibre ottiche in plastica sono disponibili non confezionati connettori simplex in plastica possono essere montati facilmente sul luogo di installazione con l attrezzo adatto e FO PCF confezionato cavi PCF confezionati con 4 connettori simplex PCF sono disponibili in lung hezze fisse Indicatori L OBT dispone di 4 LED per l indicazione dello stato di funzionamento PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Descrizione del funzionamento L 24V verde spento manca tensione di alimentazione o l alimentazione interna difet tosa o presenta cortocircuito lampeggiante tensione di alimentazione esistente velocit di trasmissione non ancora impostata luce verde velocit di trasmissione impostata tensione di alimentazione in ordine CH1 CH2 CH3 canali da 1 a 3 giallo spento i dati non vengono ricevuti luce gialla i dati vengono ricevuti
372. sity in a solid angle of 10 degrees with free emission without shadows caused by obstacles At 12 m distance from the sending PROFIBUS ILM there is an illuminated circular area with a diameter of approximately 4 m Although the send window of the PROFIBUS ILM is neither round nor square from a distance of 2 m the illuminated area is practically round since from this distance the light source can be assumed to be a point At a distance greater than 12 m in the same way as the illumination provided by a spotlight the illuminated area starts to reduce At 15 m distance an illuminated area of 2 m diameter is guaranteed Note These data are only guaranteed when the windows of the PROFIBUS ILM are clean From time to time the window should be cleaned using a clean soft cloth as usual with other optical devices or glasses Under no circumstances should aggressive or abrasive cleaning agents be used Condensation on the window or wetting with water or other liquids reduces the illumination range With condensation a reduction of approximately half of the maximum range has been measured If the liquid produces bubbles the reduction is sometimes even higher since not only the optical attenuation but also the optical refraction of the liquid takes effect 49 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 The LOW LED displays critical receive levels Minimum distance to partner ILM 0 5 m u O
373. slitta 3 verso l alto fino in fondo e to glierla Risultato la slitta non pi nel repeater RS 485 Agganciare il repeater RS 485 nella guida profilata per S7 300 4 Inclinarlo all indietro fino in fondo 5 Serrare la vite di fissaggio ad una coppia compresa tra 80 e 110 Ncm 6 Lato posteriore Lato anteriore 4 j 6 da 80 a 110 Necm Figura 5 6 Montaggio del repeater RS 485 su una guida profilata per S7 300 Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti attivi per reti RS485 Smontaggio dalla guida profilata per S7 300 Per smontare il repeater RS 485 da una guida profilata per S7 300 procedere nel modo seguente 1 Allentare la vite di fissaggio del repeater RS 485 1 2 Sfilare il repeater RS 485 spostandolo verso l alto 2 Figura 5 7 Smontaggio del repeater RS 485 dalla guida profilata per S7 300 Montaggio su una guida profilata a norma Per poter montare il repeater RS 485 su una guida profilata a norma la slitta deve trovarsi sul lato posteriore del repeater RS 485 1 Agganciare il repeater RS 485 nella guida profilata a norma 2 Spostare il repeater all indietro fino a quando la slitta scatta Smontaggio dalla guida profilata a norma Per smontare il repeater RS 485 dalla guida profilata a norma procedere nel modo seguente 1 Premere la sl
374. sono possi bili le seguenti velocit di trasmissione 9 6 kbit s 19 2 kbit s 45 45 kbit s 93 75 kbit s 187 5 kbit s 500 kbit s 1 5 Mbit s e 12 Mbit s PROFIBUS Optical Bus Terminal OBT 2 6 Un PROFIBUS Optical Bus Terminal OBT consente di collegare un nodo singolo PROFIBUS senza interfaccia FO integrata o un segmento PROFIBUS RS485 alla rete ottica PROFIBUS vedere figura 2 2 Il collegamento all interfaccia RS 485 dell OBT viene eseguito con un cavo PROFI BUS o con un cavo di connessione preconfezionato L OBT viene collegato nella linea ottica PROFIBUS tramite l interfaccia FO Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS 2 2 2 OLM Topologie con OLM Gli OLM dispongono di un canale elettrico a potenziale libero simile ad un repea ter e a seconda del modello di uno o due canali ottici Gli OLM sono adatti per velocit di trasmissione da 9 6 kbit s a 12 Mbit s La velo cit di trasmissione viene riconosciuta automaticamente Topologie lineari La figura 2 3 riporta un esempio caratteristico di topologia lineare In una struttura lineare i singoli OLM SIMATIC NET PROFIBUS sono collegati tra loro in coppia con cavi FO duplex All inizio e alla fine di una linea sono sufficienti OLM con un canale ottico al centro sono necessari OLM con due canali ottici terminali di dati vengono allacciati alle interfacce elettriche
375. ssere trasmessi al massimo 224 byte di dati utili Reti PROFIBUS SIMATIC NET 2 28 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Parametrizzazione L indirizzo PROFIBUS DP pu essere impostato tramite due interruttori rotanti riportati sul lato frontale La progettazione viene eseguita tramite il file GSD con lo strumento di progettazione dell apparecchio allacciato p es STEP 7 2 5 6 Passaggio con DP AS Interface Link 65 Struttura SIEMENS DP AS LINK ASI POWER FAIL CONFIG ERROR AUTOPROG AV CONFIG MODE dee SRO er i ASI SLAVE FAIL Figura 2 20 DP AS Interface Link 65 La DP AS Interface Link costituita da un contenitore robusto in alluminio pressofuso con classe di protezione IP 65 La sua tenuta stagna all acqua conforme alla norma Enclosures for Electrical Equipment UL 50 Typ 4 ed adatta per temerature comprese tra 25 C e 60 C Sulla superficie del contenitore si trovano i LED di diagnostica per la parte PROFIBUS DP e la parte AS Interface L indirizzo dei nodi di bus per PROFIBUS DP pu essere impostato con interruttori DIL oppure tramite una EEPROM Per l impostazione dell indirizzo tramite EEPROM pu essere utilizzato ET 200 Handheld L interfaccia DP AS pu essere montata in un punto qualsiasi e in ogni posizione L allacciamento a PROFIBUS DP viene eseguito tramite connettore tondo a 12 poli l allacciamento all AS Interface tramite un connetto
376. ssioni in base a Analisi e Ricevitore di visualizzazi misura one intensit tempo di propagazione Figura A 4 Tipo di funzionamento di un OTDR Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 TECNICA DI MISURA PROFIBUS Analisi dell OTDR L OTDR rappresenta graficamente il risultato di misura Inizio fibra v4 Accoppiamento v4 Fine fibra L Fusion Splice Backscatter Ta Power dB Bonding Splice HMI Figura A 5 Rappresentazione del risultato di misura dell OTDR La figura A 5 illustra in modo chiaro che la potenza della luce alimentata si riduce continuamente sul percorso della linea FO Sui punti di collegamento della fibra risultano chiari salti Dal risultato di misura possibile rilevare e sei punti di collegamento sono da eseguire di nuovo a causa dell attenuazione eccesiva e se durante la posa del cavo sono subentrati danni della fibra e a quale distanza dall inizio della fibra si trovano punti di disturbo Sulla base di queste informazioni possibile e eliminare in modo mirato difetti di installazione e documentare in modo esatto le linee FO e confrontare modifiche rispetto al mo mento di installazione in caso di guasto caso di garanzia s o no Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 TECNICA DI MISURA PROFIBUS A 2 4 Controllo della qualit del segnale ottico per PROFIBUS OLM V3 Per PROFIBUS OLM V3 i livelli
377. ssivi per PROFIBUS PA 6 1 FC Process Cable cavo PROFIBUS PA Guaina esterna in PVC Conduttore interno in rame massiccio Schermo a maglia in rame Foglio in materiale sintetico Protezione di isolamento in PE cellulato Materiale di riempimento Figura 6 1 Principio di struttura del cavo di bus FC per PROFIBUS PA Cavi di bus FC per PROFIBUS PA 6XV1 830 5EH10 e 6XV1 830 5FH10 I cavi di bus 6XV1 830 5EH10 guaina blu e 6XV1 830 5FH10 guaina nera sono cavi standard per reti PROFIBUS PA Essi possono essere utilizzati in generale per tutti gli impianti con tecnica trasmissiva secondo IEC 61158 2 come p es Foundation Fieldbus e PROFIBUS PA Essi soddisfano i requisiti del cavo tipo A secondo IEC 61158 2 vedere anche capitolo 4 La combinazione di conduttori intrecciati e schermo a maglia li rende particolarmente adatti per la posa in ambiente industriale con disturbi elettromagnetici La struttura garantisce inoltre un elevata stabilit delle propriet elettriche e meccaniche dopo l installazione La struttura del cavo permette l impiego del FastConnect FC Stripping Tool per rimuovere rapidamente la guaina esterna Vedere capitolo 4 2 3 Propriet e difficilmente infiammabile e autoestintore in caso di incendio e resistente a radiazioni UV e resistente con limitazioni a grassi e oli minerali e l FC Process Cable corrisponde al modello FISCO Applicazione Il cavo di bus concepito per il collegamento del bus con tecnica tr
378. sso viene realizzato un collegamento punto a punto tra misuratore e nodo Successivamente con il bus cablato viene controllata la raggiungibilita degli slave allacciati Durante questa operazione l utente pu far generare automaticamente una lista di tutti gli slave raggiungibili ma anche controllare la disponibilit di un singolo slave immettendo automaticamente il relativo indirizzo Visualizzazione del risultato di misura Oltre al risultato di misura vero e proprio nel display vengono visualizzati anche i provvedimenti corretti per eliminare i guasti Anche durante la misurazione della riflessione viene visualizzata la posizione del guasto In questo modo per utilizzare il dispositivo di test non sono necessarie conoscenze specifiche di PROFIBUS per localizzare ed eliminare guasti caratteristici durante il cablaggio e il montaggio Per le misurazioni non sono necessari apparecchi supplementari L utilizzo di questo dispositivo di test consente di ridurre drasticamente i tempi di messa in funzione e i tempi di fermo dell impianto Documentazione dello stato dell impianto Il BT 200 semplifica la creazione di un protocollo di collaudo per la documentazione dello stato dell impianto al momento della consegna Come standard l apparecchio configurato per il funzionamento su cavi PROFIBUS secondo il tipo A EN50170 La parametrizzazione di questo apparecchio pu tuttavia essere modificata immettendo i parametri elettrici per il cavo da mi
379. stallazione dei cavi all esterno di armadi e all interno di edifici va osservato quanto segue C 16 In caso di installazione in tracciati di cavi comuni necessario rispettare le di stanze tra le singole categorie di cavi in base alla tabella C 1 Se la posa dei cavi viene eseguita in canali di cavi metallici questi canali pos sono essere disposti direttamente uno di fianco all altro Se per tutte le categorie disponibile un solo canale di cavi metallico devono essere rispettate le distanze specificate nella tabella C 1 oppure se ci non dovesse essere possibile per motivi di spazio le singole categorie devono es sere delimitate da setti separatori metallici setti separatori devono essere col legati al canale a bassa resistenza e a bassa induttanza Gli incroci di tracciati di cavi devono essere eseguiti ad angolo retto Tra le singole parti dell impinto necessario includere nell equipotenzialit dell edificio canali passerelle di conduzione metalliche per cavi Osservare le avvertenze relative all equipotenzialita riportate nel capitolo C 4 4 del presente manuale Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus C 5 4 Installazione dei cavi fuori da edifici Prediligere cavi in fibra ottica Per i collegamenti di bus tra edifici e tra edifici e dispositivi esterni si raccomanda l impiego di cavi in fibra ottica FO Grazie al principio di trasmissio
380. standard norme e direttive IEC 61158 2 to 6 1993 2000 Digital data communications for measurement and control Fieldbus for use in industrial control systems EN 50170 1 2 1996 General purpose field communication system Volume 2 Physical Layer Specification and Service Definition Direttive PNO Indicazioni per l implementazione di PROFIBUS per la proposta di norma DIN 19245 parte 3 Versione 1 0 del 14 12 1995 Tecnica trasmissiva ottica per PROFIBUS Versione 2 1 del 12 98 EIA RS 485 1983 Standard for Electrical Characteristics of Generators and Receivers for Use in Balanced Digital Multipoint Systems SIMATIC NET PROFIBUS PA basata sui seguenti standard norme e direttive EN 50170 1 2 1996 General Purpose Field Communication System Volume 2 Physical Layer Specification and Service Definition IEC 61158 2 1993 Fieldbus standard for use in industrial control systems Part 2 Physical layer specification and service definition EN 61158 2 1994 Fieldbus standard for use in industrial control systems Part 2 Physical layer specification and service definition Relazione PTB W 53 1993 Esaminazione della sicurezza intrinseca dei sistemi di bus di campo Braunschweig marzo 1993 Direttive PNO 1996 PROFIBUS PA Guida per la messa in funzione avvertenze per l utilizzo della tecnica IEC 61158 2 per PROFIBUS N art 2 091 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 1 7 RETI PROFIBUS
381. sterna Se tutti gli indicatori sono corretti e tuttavia subentrano disturbi di comunicazione p es la conferma rimane disattivata telegrammi inattesi necessario controllare i tempi di controllo impostati nei nodi PROFIBUS come p es lo Slot Time Per informazioni pi dettagliate consultare la descrizione del terminale PROFIBUS e il software di progettazione utilizzati PROFIBUS Optical Busterminal OBT 6 1 C79000 G8972 C1 22 02 PROFIBUS Optical Busterminal OBT C79000 G8972 C1 22 02 Dati tecnici Tabella 7 1 Dati tecnici Dati tecnici Tensione d esercizio tensione di funzionamento a 24 VDC da 18V a 32V basso voltaggio con separazione SELV o secondo NEC classe 2 Corrente assorbita su ingresso 24V max 200 MA Velocit di trasmissione 12 MBit s 6 MBit s 3 MBit s 1 5 MBit s 500 kBit s 187 5 kBit s 93 75 kBit s 45 45 kBit s 19 2 kBit s 9 6 kBit s Impostazione velocita di trasmissione viene eseguita automaticamente Modo operativo linea ottica Velocita errore bit lt 1079 Ingresso canali da 1 a 3 Lunghezza bit da 0 7 a 1 3 tBit Jitter da 0 03 a 0 03 tBit Uscita canali da 1 a3 Lunghezza bit da 0 99 a 1 01 tBit Jitter da 0 003 a 0 003 tBit Tempo di attraversamento segnale ingresso uscita lt 6 tBit qualunque Profondit di cascata linea ottica limitata solo da tempo di attraversamento segnale Canale elettrico Segnale di ingresso uscita livello RS 485 Resiste
382. surare In questo modo possibile una visualizzazione in caso di utilizzo di tipi di cavo qualsiasi della posizione del guasto in metri oppure la lunghezza complessiva del cavo installato Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 A 5 TECNICA DI MISURA PROFIBUS Funzionamento con accumulatore L apparecchio munito di accumulatore In questo modo possibile garantire l esecuzione delle misurazioni indipendentemente dalla rete nell intero impianto Grazie alla funzione di disattivazione automatica dopo 3 minuti di non utilizzo possibile un funzionamento economico e una maggiore durata dell accumulatore Dati per l ordinazione Dispositivo di test HW BT200 6ES7 181 0AA00 0AA0 Cavo punto a punto per l allacciamento dei nodi Con connettore di test Con istruzioni per l uso in tedesco inglese Caricabatteria non compreso nella fornitura Caricabatteria 230V AC 2 4 10 V DC 6GT2 003 1AA00 Caricabatteria 110V AC 2 4 10 V DC 6EP8106 0HB01 Connettore di test come ricambio 6EP8 106 0AC20 Confezione di accumulatori NC 6EP8106 0HA01 come ricambio Cavo punto a punto come ricambio 6EP8106 0HC01 Le istruzioni per l uso possono essere scaricate gratuitamente da Internet con l ID articolo 857969 www ad siemens de simatic cs Reti PROFIBUS SIMATIC NET A 6 6GK1970 5CA20 0AA4 Edizione 2 05 2000 TECNICA DI MISURA PROFIBUS A 2 A 2 1 Tecnica di misura per FO
383. ta la conversione inversa con un ulteriore copia di OLM OBT PC SIMATIC S7 400 ET200M con Disp di programm con IM467 FO ottica integrata Operator Panel OLM G11 Resistenza terminale attivata 1 Cavo PROFIBUS con terminazione su entrambi i lati 2 Cavo a due fibre ottiche di plastica o PCF 3 Cavo a fibre ottiche per percorsi lunghi Figura 4 1 Esempio di un collegamento di percorsi lunghi di cavi a fibre ottiche con OBT e OLM La velocit di trasmissione massima ammessa il tipo e la lunghezza massima del percorso di cavi a fibre ottiche viene determinato dal tipo di OLM 4 3 Collegamento di segmenti RS485 L OBT permette l allacciamento di un singolo nodo PROFIBUS DP Per il collega mento di segmenti RS485 con pi di un nodo disponibile un ulteriore componente di rete OLM12M Per poter impiegare OLM12M necessario che la rete PROFI BUS BT venga utilizzata con una velocit di trasmissione di 187 5 kBit s 500 kBit s 1 5 MBit s o 12 Mbit s canali ottici dell OLM12M possono essere collegati al PROFIBUS DP ottico con OBT o altri dispositivi SIMATIC nel modo seguente PROFIBUS Optical 4 2 Busterminal OBT C79000 G8972 C122 02 Topologia della rete Il collegamento viene eseguito con un cavo a due fibre ottiche di plastica lunghzza massima 50 m o PCF lunghezza massima 300 m il cavo a fibre otti che confezionato su entrambi i lati con connettori simp
384. tance and low inductance connection to ground or the vehicle chassis Adjustable so that optimum alignment along the optical axis to the partner station is possible Simple and cheap to make Corrosion proof depending on the characteristics of the installation site One possible design of a support is the mounting angle shown in Figure 12 This can be made easily in any workshop cutting sheet metal bending drilling Each support requires two identical angles to allow adjustment in two axes The angles are bolted together with standard components such as M4 or M6 bolts washers or toothed washers and M4 and M6 nuts 3 mm thick sheet aluminum is for example suitable or galvanized 2 mm sheet steel If suitable profile material is available this makes construction even simpler since it is not necessary to bend the arm 31 Copyright by Siemens Infrared Link Modul ILM 6ZB530 3AC30 0BA1 Thickness of sheet approx 3 mm depending on mech requirements ww 08 ww 08 Figure 12 Example of a Simple Mounting Bracket Instead of drilling individual holes in a circular arc with a diameter of 171 1 mm with 4 5 mm diameter pairs of holes opposite each other you can also cut two arc shaped slits in the plate This requires a cutting device but has the advantage that the ILM can be aligned continuously and therefore more accurately on the vertical axis during operation Copyright by Siemens 32 6ZB5530 3AC30 0BA
385. tante Lo schermo del connettore non deve avere un contatto indefinito e casuale con parti di costruzione conduttrici in quanto potrebbero verificarsi correnti dello schermo indefinite Collegare il contenitore del connettore in modo permanente al potenziale di terra oppure ad un isolamento che impedisce un contatto sicuro Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 63 Componenti passivi per reti RS 485 Rispetto delle condizioni ambientali Osservare che un cavo di connessione standard non resiste alle stesse condizioni ambientali di un cavo di bus passante Provvedere eventualmente ad una prote zione supplementare dei punti di collegamento contro umidit polvere o gas ag gressivi inserendo i punti di collegamento in una muffola di giunzione per cavi Le fonti di riferimento si trovano nell appendice 1 2 SIMATIC NET Support e Trai ning Reti PROFIBUS SIMATIC NET 4 64 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Componenti passivi per reti RS 485 4 9 Cavo di connessione confezionato 4 9 1 Cavo di connessione 830 1T Settore d impiego Il cavo di connessione 830 1T un cavo confezionato per l allacciamento rapido ed economico di terminali di dati a OLM e OBT Struttura Il cavo di connessione 830 1T costituito da una coppia di conduttori intrecciati conduttori di fili di rame con uno schermo a maglia Enbrambe le estremit di questo cavo sono munite rispettivamente di un connettore Sub
386. tecnica e solo in combinazione con apparecchiature e componenti esterni omologati dalla Siemens Per garantire un funzionamento inaccepibile e sicuro del prodotto assolutamente necessario un tra sporto immagazzinamento un installazione ed un montaggio conforme alle regole nonch un uso accu rato ed una manutenzione appropriata Marchi SIMATIC SIMATIC HMI e SIMATIC NET sono marchi registrati della SIEMENS AG Tutte le altre sigle qui riportate possono corrispondere a marchi il cui uso da parte di terzi pu violare i diritti dei possessori Copyright Siemens AG 1998 All rights reserved La duplicazione e la cessione della presente documentazione sono vietate come anche l uso improprio del suo contenuto se non dietro previa autorizzazione scritta Le trasgressioni sono punibili di risarcimento dei danni Tutti i diritti sono riservati in particolare quelli relativi ai brevetti e ai marchi registrati Siemens AG Divisione automazione Sistemi per l automazione industriale Postfach 4848 D 90327 N rnberg Esclusione della responsabilit Abbiamo controllato che il contenuto della presente documentazione corri sponda all hardware e al software Non potendo tuttavia escludere eventuali differenze non garantiamo una concordanza totale Il contenuto della pre sente documentazione viene tuttavia verificato regolarmente e le correzioni o modifiche eventualmente necessarie sono contenute nelle edizioni succes
387. tell Nummer Ord code 6GK1905 0AC00 Montage Mounting i 1 SpliTConnect Coupler 8 auf einen freien Leitungs abgang eines SpliTConnect Tap 1 aufschrauben Srew the SpliTConnect Coupler 8 onto a free port 2 SpliTConnect Coupler 8 auf einen freien Leitungs abgang eines zweiten SpliTConnect Tap 1 auf schrauben Kontaktierelemente 2 auf die komplett of the SpliTConnect Tap 1 best ckten SpliTConnect Tap aufschrauben Srew the SpliTConnect Coupler 8 onto a free port of a second SpliTConnect Tap 1 Screw contac ting element 2 onto the completely assembled SpliTConnect Tap Bestell Nummer Ord code 6GK1905 0AB00 Beschreibung Description Abgang mit M 12 Buchse Verwendung anstelle des Abgangs f r Leitungsanschluss Port with M12 socket To be used instead of the port for cable connection Typ Type SpliTConnect M12 Outlet Montage Mounting Schirm Signal A Shield PIN 3 PIN 4 Signal B Mics PIN 1 2 Kontaktierelement 2 auf den komplett be st ckten SpliTConnect Tap 1 aufschrauben Screw contacting element 2 onto the completely assembled SpliTConnect Tap 1 1 SpliTConnect M12 Outlet 9 auf einen freien Leitungsabgang eines SpliTConnect Tap 1 auf schrauben Screw the SpliTConnect M12 Outlet 9 onto a free port of the SpliTConnect 1 Copyright 1999 Siemens AG Montageanleitung f r SIMATIC NET PROFIBUS S
388. th unconnected contacts for further processing The mechanical design consists of acompact stable metal housing which can be mounted on a hat rail or mounting plate as required The module is configured using easily accessible switches The PROFIBUS OLM complies with the standard EN 50170 and the technical guidelines issued by the PROFIBUS user organization PNO PROFIBUS optical transmission technology OLM G12 und OLM G12 EEC have the same function They only differ in the specification of the climatic ambient conditions while the OLM G12 is suitable for employment in the standard temperature range from 0 C to 60 C the OLM G12 EEC extended environmental conditions can be used in the extended temperature range from 20 C to 60 C and at up to 100 humidity 6 Version 1 1 8 00 2 General Functions 2 1 Non operating mode related functions 2 General Functions 2 1 Non operating mode related functions Transmission rate The PROFIBUS OLMs support all the transmission speeds transmission rates defined in the EN 50170 standard 9 6 kBit s 19 2 kBit s 45 45 kBit s 93 75 kBit s 187 5 kBit s and 500 kBit s and additionally 1 5 MBit s 3 MBit s 6 MBit s and 12 MBit s The transmission rate is set automatically as soon as the PROFIBUS OLM receives a frame The setting or adjust ment is dependent on the transmission rate and the set operating mode Depending on the OLM this can last a maximum of between 0 5 s at 12 MB
389. the receiving diode is exceeded and errors in the data can occur The infrared wavelength used cannot be seen by the human eye The PROFIBUS ILM therefore indicates when other light sources subject it to an illegally high infrared radiation by lighting up the red ERROR LED The user can also configure a switch to activate the signaling contact in this situation Copyright by Siemens 18 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM 5 6 Monitoring the Optical Link The PROFIBUS ILM has two mechanisms with which it monitors problems on the optical link monitoring of the optical receive activity monitoring of the optical link with an acknowledgment pulse 5 6 1 Monitoring the Optical Receive Activity With the yellow RX LED the PROFIBUS ILM indicates the reception of data via the optical channel of the PROFIBUS ILM The pulse for the LED is extended to approximately 300 ms so that it is possible to recognize data reception even when small amounts of data are received Apart from the optical display using the RX LED the PROFIBUS ILM also has integrated monitoring logic that triggers the signaling contact when problems occur receiving data on the optical channel provided the user configures this function with a switch Problems in reception on the optical channel occur when there has been no change in the status of the optical receive channel for a period of approximately 300 ms in other words when no message was
390. tic cables 6GK1 901 0FB00 0AA0 Page 11 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for Simplex Connectors Plug adapter Pack of 50 for installing plastic simplex connectors in conjunction with for example IM 467 FO and IM 153 2 FO 6ES7 195 1BE00 0XA0 Other commercially available accessories e Sharp scissors for shortening the Kevlar and the fibers e Sharp knife for separating the duplex cords e Clean soft cloth for cleaning the polishing holder and the connector end face Page 12 SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors SIEMENS SIMATIC NET Product Information Dated 08 99 Installation Instructions for SIMATIC NET PROFIBUS Plastic Fiber Optic with BFOC Connectors This document contains information in English SIEMENS AG 1999 Page 1 Subject to change SIMATIC NET PROFIBUS Plastic Fiber Optic Installation Instructions for BFOC Connectors We have checked the contents of this manual for The reproduction transmission or use of this document agreement with the tools described Since or its contents is not permitted without express written deviations cannot be precluded entirely we cannot authority Offenders will be liable for damages All rights guarantee full agreement However the data in this including rights created by patent grant or registration of manual are reviewed regularly and any necessary a utility or design are reserved
391. tica di plastica con connettore simplex si torvano e nell appendice D del presente manuale e in Internet tedesco http www ad siemens de csi net inglese http www ad siemens de csi_e net Selezionare in questa pagina di Internet SEARCH funzione di ricerca immet tere in articolo con ID il numero 574203 e avviare l operazione di ricerca e come allegato del set di connettori simplex set di pulitura vedere tabella 7 6 Titolo struzioni di montaggio per SIMATIC NET PROFIBUS Plastic Fiber Optic con connettori simplex Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 7 29 Componenti passivi per reti ottiche 7 4 3 Connettore BFOC per OLM Il connettore BFOC permette collegamenti precisi di cavi in fibra ottica La struttura del connettore BFOC permette di utilizzare lo scarico di toro dei cavi Esso indip sensabile per la realizzazione di lunghi collegamenti FO p es tra diversi OLM P connettori BFOC devono essere ordinati separatamente Le informazioni per l ordinazione e le istruzioni per la confezione sono riportate nell appendice D Figura 7 10 Connettore BFOC con accessori capicorda a crimp e protezione antipiega per FO in plastica 7 4 4 Connettore per FO in vetro Connettore BFOC per FO in vetro Per PROFIBUS vengono impiegati solo connettori BFOC per fibre ottiche di vetro Figura 7 11 Connettore BFOC con cappuccio parapolvere Reti PROFIBUS SIMATIC NET 7
392. tierelement 2 losschrauben und von 2 Leitung mit FastConnect Stripping Tool 2 SpliTConnect Tap 1 abziehen abisolieren Screw off contacting element 2 and remove it Strip off cable by using the FastConnect Stripping from the SpliTConnect Tap 1 Tool 1 3 Mutter 3 Dichtung 4 und Schirmkontaktier 4 Litzenhalter 6 auf die nicht abisolierten Litzen element 5 auf die Leitung schieben aufstecken Achtung Metallseite M des Schirmkontaktierele Achtung Farbcodierung beachten mentes 5 mu in Richtung Litzenhalter 6 zeigen Insert the strand holder 6 onto the not stripped Assemble cable with nut 3 seal 4 and shield off strands contacting element 5 Attention Follow the colour coding Attention Metal side M of the shield contacting element 5 must point to the strand holder 6 5 Best ckte Leitung in den SpliTConnect Tap 1 ein A 2 f hren dabei Kodierung K beachten ng Insert the assembled cable into the SpliTConnect See Mounting la ofthe Tap 1 and pay attention to the coding K in doing so FastConnect Stripping Tool Copyright 1999 Siemens AG Montageanleitung f r SIMATIC NET PROFIBUS SpliTConnect System Mounting Instruction for SIMATIC NET PROFIBUS SpliTConnect System Montage Mounting SpliTConnect Tap 6 Mutter 3 bis zum Anschlag anziehen 7 Montageschritte 2 bis 6 fur die zwei anderen Tighten nut 3 as much as possible Le
393. tion ITP Industrial Twisted Pair Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Informazioni generali LAN LED FO MPI NRZ OBT OLM OP PCF PE PG PMMA PNO POF PROFIBUS DP PROFIBUS PA PTB PUR PVC SELV UL UV VDE H 2 Infrarossi Local Area Network Light Emitting Diode Cavo in fibra ottica Multipoint Interface Non Return to Zero Optical Bus Terminal Optical Link Module Operator Panel Polymer Cladded Fiber Polietilene Dispositivo di programmazione Polimetilmetacrilato Organizzazione utenti PROFIBUS Polymer Optical Fiber Periferia decentrata PROFIBUS Automazione di processo PROFIBUS Physikalisch Technische Bundesanstalt Poliuretano Cloruro di polivinile Safety extra low Voltage tensione si sicurezza a basso voltaggio secondo EN 60950 Underwriter Laboratories Raggi ultravioletti Associazione elettronica tedesca Fattore capacitivo Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Bibliografia Norme manuali e ulteriori informazioni 1 2 3 4 5 6 EN 50170 1 2 1996 General Purpose Field Communication System Volume 2 Physical Layer Specification and Service Definition Direttiva PNO Indicazioni per l implementazione di PROFIBUS per la poposta di norma DIN 19245 parte 3 Versione 1 0 del 14 12 1995 Direttiva PNO Tecnica trasmissiva ottica per PROFIBUS Versione 2 1 del 12 98 EIA RS
394. tion Pull in the cable using only the loop Never pull on the protective sleeve or the outer jacket of the cable After the cable has been installed the pulling loop must be Free the cords from the protective sleeve and cut away the removed Cut open the back end of the protective sleeve with Kevlar fibers with scissors scissors for a length of approximately 10 cm Caution Never cut the black or orange cords Caution Make sure that you do not damage the cords beneath the protective sleeve gj Carefully remove the pulling loop from the end of the cable by The job is done pulling on the loop Page 4 SIMATIC NET PROFIBUS PCF Fiber Optic Standard Cable Marking of the SIMATIC NET PROFIBUS PCF Fiber Optic Standard Cable ks ce To help you connect up the cable First connect the orange cord The black cord is then connected to the correctly the PCF standard cable has e If the arrow on the orange cord is free socket of the same FO interface arrow markings on the orange cord pointing out of the cable connect this This helps to make sure that you attach cord to the receiver The receiver is one end of a cord to the transmitter and identified by an arrow pointing into a the other to a receiver crossed over circle cords If the arrow on the orange cord points into the cable picture connect this Remove the dust cap shortly before you cord to the transmitter The transmitter insert the connector into the socket is i
395. tion approx 8 mm aw Zu Fold back braided shield Cable clamp ch P i approx 8 mm Cable installed FAN P I dh Figure 16 Connecting the PROFIBUS Cables Fold back the braided shield over the outer jacket of the LAN cable This provides you with a sufficiently large cable diameter to clamp the cable Screw the threaded cable inlet so that if IP65 is required the cable connection is watertight If this is required PROFIBUS cables with a round cross section and an outer diameter of 7 5 to 10 mm must be connected Tighten the threaded cable inlet with a torque of approx 2 5 to 3 Nm so that the collar of the cable inlet is sealed against the casing of the PROFIBUS ILM When the cable is connected the union nut of the cable inlet must be tightened so that the cable can no longer be pulled out When tightening the nut make sure that the cable does not turn with it If a union nut must be released again the threaded cable inlet should be tightened again afterwards to make sure that this is still flush against the casing Copyright by Siemens 36 6ZB5530 3AC30 0BA1 Infrared Link Modul ILM If the device is at the start or end of an electrical PROFIBUS segment you must seal one threaded cable inlet using the accompanying sealing plug If the mechanical stress on the PROFIBUS cable is liable to change make sure that you install additional strain relief
396. to Port 1 module and another bus subscriber connected via Port 1 are both sending at no signal the same time e g because an address has been assigned twice the setting of the slot time is too low or during lifting of the segmentation in the optical line see Chap 3 1 1 RS 485 driver of the module is defective e g after lightning strike PROFIBUS frames are being received at the optical port Operating mode Line with optical fiber link monitoring and Transmission rate has not yet been recognized LED System flashes red Redundant optical ring No transmitting bus subscriber present Send and receive optical fibers have been transposed No partner module connected or partner module is not switched on Connected partner module is defective Transmission rate has been recognized LED System flashes green If the operating mode Redundant optical ring has been set the optical port works as a stand by port There is no malfunction in the OLM or the optical fiber If one of the operating modes Line with optical fiber link monitoring has been set no PROFIBUS frames are received at the optical port There is no malfunction in the OLM or the optical fiber Transmission rate has been recognized LED System lights green or flashes red green No transmitting bus subscriber present optical fiber connection is OK Send and receive optical fibers
397. to principale di PROFIBUS DP consiste nello scambio dei dati ciclico e rapido tra il master DP centrale e le apparecchiature periferiche PROFIBUS FMS Sistema di bus PROFIBUS con il protocollo FMS FMS significa Fieldbus Mes sage Specification Progettazione Progettazione significa immettere una configurazione PROFIBUS con tutti i para metri specifici utilizzando p es STEP 7 o COM PROFIBUS Repeater RS 485 Mezzo d esercizio per rafforzare i segnali di bus e gli accoppiamenti di seg menti su grandi distanze Resistenza del conduttore Resistenza complessiva del conduttore di andata e di ritorno di un cavo Resistenza terminale una resistenza per l adattamento della potenza del cavo di bus le resistenze terminali sono generalmente necessarie sulle estremit dei cavi e dei segmenti In SIMATIC NET PROFIBUS le resistenze terminali vengono attivate disattivate nel connettore di bus o nel bus terminal oppure come Terminator Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Glossar 5 Glossario Ridondanza Esistenza di risorse non necessarie per il funzionamento di base In caso di gua sto di una risorsa interviene la risorsa supplementare che assume questa fun zione Esempio Ridondanza dei mezzi di trasmissione Una linea di collegamento supplementare che chiude la linea in un anello in caso di guasto di una linea la linea sostitutiva viene attivata e impedisce il guasto d
398. tra di loro Il fattore capacitivo in un gruppo non deve essere maggiore di 5 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Cavo di bus gt 10m gt 10m S7 400 S7 300 Cavo di bus p es 5m W 1 5 1 0 0 1 2 6 5 m gt 2 6 m somma dei valori capacitivi in metri S7 400 IN il W 1 0 Eo Ser W 0 1 Cavo di bus p es gruppo di 0 5 m W 1 5 1 5 0 5m lt 3m formazione di gruppi somma dei fattori capacitivi lt 5 S7 400 S7 400 3 7 Progettazione di reti 3 1 3 Segmenti per velocit di trasmissione fino a max 12 Mbit s Velocit di trasmissione fino a max 12 Mbit s Tabella 3 6 Lunghezze di segmento realizzabili Lunghezza di segmento per il tipo di cavo a Ai FC Standard Cable FC Trailingcable Velocit di kasmis _ FC Robust Cable PROFIBUS Flexible Cable FC FRNC Cable PROFIBUS Festoon Cable FC Food Cable FC Underground Cable Cavo marino SIENOPYR FR Durante la progettazione di segmenti con velocit di trasmissione da 3 Mbit s a max 12 Mbit s necessario osservare quanto segue e Per accoppiamento di terminali di dati a segmenti di bus possono essere utilizzati solo i connettori di bus ammessi per 1
399. ttamente alla ditta Dehn amp S hne i dati per l ordinazione sono riportati nelle pagine seguenti e Durante la progettazione di una rete necessario osservare che la protezione di massima e quella di fine devono essere considerate come un nodo ridu zione del numero di nodi in segmenti con moduli di protezione antifulmine e Se un segmento PROFIBUS attraversa diversi edifici impiego di pi compo nenti di protezione antifulmine consecutivi necessario installare in ogni edifi cio un repeater per la riproduzione del segnale Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Protezione contro fulmini e sovratensioni per cavi di bus che si estendono in pi edifici s Protezione di fine Struttura uguale della n nelle vicinanze del protezione necessaria per uaus x Protezione di massima primo nodo altri ingressi o uscite dei cavi all ingresso dell edificio Cavo per il collegamento a terra cavo equipotenziale Figura B 1 Concetto di protezione antifulmine per cavi di bus che si estendono in pi edifici Reti PROFIBUS SIMATIC NET B 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Protezione contro fulmini e sovratensioni per cavi di bus che si estendono in pi edifici B 2 1 Istruzioni di installazione per protezione di massima La protezione di massima deve essere installata sul cavo di bus all ingresso dell edificio e collegata a bassa impedenza all equipotenzialit dell edifici
400. ttivata Se la resistenza terminale viene involontariamente attivata al centro del cavo di bus questo errore viene immediatamente identificato e quindi localizzato dal nodo non pi raggiungibile Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 4 35 Componenti passivi per reti RS 485 Scollegamento di una stazione Il connettore di bus permette di scollegare un nodo di bus senza interrompere il traffico di dati sul bus Non ammesso sfilare il connettore di bus con la resistenza terminale attivata sulle estremit del cavo di bus in quando comporta disturbi al bus Connettore di bus con connettore femmina PG Si raccomanda di inserire in ogni segmento di bus almeno un connettore di bus con connettore femmina PG In questo modo si facilita la messa in funzione con PG e PC Nei connettori di bus con connettore femmina PG tutti i contatti 1 1 sono collegati con i poli del connettore vale a dire che l assegnazione dei pin corrisponde allas segnazione dell apparecchio collegato Assegnazione dei pin del connettore Sub D 4 36 La tabella 4 8 riporta l assegnazione dei pin del connettore Sub D a 9 poli Tabella 4 8 Assegnazione dei pin del connettore D Sub a 9 poli N pin Nome se Denominazione gnale 1 2 i i 3 RxD TxD P Cavo dati B 4 3 5 M5V2 Potenziale di riferimento dati dalla stazione 6 P5V2 Alimentazione positiva dalla stazione 7 2 8 RxD TxD N Cavo dati A
401. tura per una curvatura per curvature ripetute Forza di tiro massima am messa Peso ca Indipendenza da alogeno Resistenza all incendio Resistenza all olio Cavi di bus per PROFIBUS 2 FC Trailin Cable 6 4 6XV1 830 3EH10 lt 49 dB km lt 25 dB km lt 4 dB km lt 3 dB km Festoon Cable 4 6XV1 830 3GH10 lt 49 dB km lt 25 dB km lt 4 dB km lt 3 dB km Flexible Cable 6 4 6XV1 830 0FH10 lt 49 dB km lt 25 dB km lt 4 dB km lt 3 dB km FC Process Cable f r IEC 61158 2 7 6XV1 830 5EH10 5FH10 lt 3 dB km 100 20 Q 100 Q Cavo marino SIENOPYR FR 6XV1830 0MH10 lt 45 dB km lt 22 dB km lt 5 dB km lt 3 dB km lt 133 Q km lt 133 Q km lt 133 Q km lt 44Q km lt 110 Q km lt 14Q km lt 19 Q km ca 28 5 nF km ca 28 5 nF km 02YY ST C11Y 02Y ST CY 1x2x0 64 2 55 150 KF LI 40 FR petrol PUR petrolio 8 0 0 4 mm 40 C 60 C 40 C 60 C 40 C 60 C gt 40 mm gt 30 mm gt 60 mm 2 gt 70 mm 2 lt 14 Q km ca 28 nF km Bo ca 30 nF km 5 lt 100 V lt 100 V lt 100 V Du ST C x 02Y ST C11Y 1x2x0 65 2 56 150 LI VI 150 LI petrolFR FRNC PVC speciale petrolio 8 0 0 3 mm 40 C 60 C 40 C 60 C 40 C 60 C PUR viola 8 0 0 4 mm 40 C 60 C 40 C 60 C 40 C 60 C 02Y SY ST CY 1x2x1 0 2 55 100 BL OE FR PVC blu nero 8 0 0
402. un master AS Interface e per PROFIBUS DP della funzionalit di uno slave PROFIBUS DP Alla DP AS Interface Link possono essere allacciati fino a 31 slave AS Interface Di conseguenza la DP AS Interface Link costituisce per PROFIBUS DP uno slave modulare con un massimo di 31 moduli Reti PROFIBUS SIMATIC NET 2 30 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Parametrizzazione 2 5 7 Struttura La DP AS Interface Link come tutti gli altri componenti del sistemi periferico decentrato ET 200 parte integrante di STEP 7 e COM PROFIBUS Grazie ad una guida contestuale possibile richiamare in qualsiasi momento informazioni relative alla progettazione durante il comando del software di parametrizzazione Passaggio con DP AS Interface Link 20 Figura 2 22 DP AS Interface Link 20 La DP AS Interface Link 20 costituita da un contenitore piccolo e compatto con classe di protezione IP20 LED sul frontalino indicano e indicazione di stato dell AS Interface e slave allacciati e attivi con relativa disponibilit al funzionamento e indirizzo slave PROFIBUS e errore di bus PROFIBUS e diagnostica Inoltre la DP AS Interface Link 20 dispone di una tastiera per la commutazione dello stato di funzionamento per l acquisizione della configurazione esistente e per l impostazione dell indirizzo slave PROFIBUS Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 2 31 Topologie
403. un montaggio conforme alle regole nonch un uso accurato ed una manutenzione appropriata Marchio di prodotto SIMATIC SIMATIC HMI e SIMATIC NET sono marchi registrati della SIEMENS AG HCS un marchio registrato di Ensign Bickford Optics Company La denominazione di altri prodotti menzionati in questa documentazione possono essere marchi il cui uso da parte di terzi per propri scopi potrebbe violare i diritti di propriet Copyright Siemens AG 1999 All rights reserved La duplicazione e la cessione della presente documentazione sono vietate come anche l uso improprio del suo contenuto se non dietro previa autorizzazione scritta Le trasgressioni sono punibili di risarcimento dei danni Tutti i diritti sono riservati in particolare quelli relativi ai brevetti e ai marchi registrati Siemens AG Bereich Automatisierungs und Antriebstechnik Gesch ftsgebiet Industrielle Kommunikation Postfach 4848 D 90327 N rnberg Esclusione della responsabilit Abbiamo controllato che il contenuto della presente documentazione corris ponda all hardware e al software Non potendo tuttavia escludere eventuali differenze non garantiamo una concordanza totale Il contenuto della pre sente documentazione viene tuttavia verificato regolarmente e le correzioni o modifiche eventualmente necessarie sono contenute nelle edizioni succes sive Saremo lieti di ricevere qualunque tipo di proposta di miglioramento Siemens AG 199
404. urbi elettromagnetici e non sono necessari elementi di protezione antifulmine supplementari e semplice posa dei cavi FO e alta disponibilit della LAN grazie all utilizzo della topologia ad anello e semplice tecnica di allacciamento utilizzando cavi in fibra ottica di plastica nel campo locale Limitazioni e i tempi di esecuzione del telegramma aumentano rispetto ad una rete elettrica e la confezione dei cavi in fibra ottica di vetro necessitano di conoscenze e at trezzi specifici e assenza di tensione di alimentazione sui punti di accoppiamento del segnale allacciamenti dei nodi OLM OBT interrompe il flusso del segnale Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 RETI PROFIBUS Propriet della tecnica trasmissiva ottica La tecnica trasmissiva ottica ha le seguenti propriet Topologia della rete Struttura lineare con interfacce ottiche integrate e OBT struttura lineare a stella o ad anello con OLM Cavo in fibra ottica con fibre di vetro PCF o plastica Lunghezze di collegamento realizza con fibre di vetro fino a 15 000 m a seconda del tipo di fibra e bili punto a punto di OLM con fibre di plastica OLM da0ma80m OBT daima50m Velocit di trasmissione 9 6 kbit s 19 2 kbit s 45 45kbit s 93 75 kbit s 187 5 kbit s 500 kbit s 1 5 Mbit s 3 Mbit s 6 Mbit s 12 Mbit s max 127 per ogni rete 126 per struttura ad anello con OLM non con interfacce ottiche e OBT integrati
405. us Collegare il cavo equipotenziale su un ampia superficie di contatto alla terra al conduttore di protezione Proteggere il cavo equipotenziale da corrosione Installare il cavo equipotenziale in modo che non vi siano superfici tra il cavo equipotenziale e i cavi di segnale Utilizzare cavi equipotenziali di rame o acciaio zincato Tra le singole parti dell impinto necessario includere nell equipotenzialit dell edificio canali passerelle di conduzione metalliche per cavi A tale scopo i singoli segmenti dei canali delle passerelle per cavi devono essere collegati tra loro a bassa resistenza e a bassa induttanza e allacciati con la massima fre quenza possibile alla rete di terra dell edificio giunti di dilatazione e i collega menti snodati devono inoltre essere collegati a ponticello tramite bande flessibili di messa a terra collegamenti tra i singoli segmenti di cavi devono essere protetti da corrosione stabilit di lunga durata In caso di impiego tra settori di edifici p es separati da giunti di dilatazione con punto di riferimento proprio per la rete di terra dell edificio deve essere in stallato un conduttore equipotenziale sezione di Cu equivalente gt 10mm pa rallelamente ai cavi Questo conduttore equipotenziale non necessario se vengono impiegati canali passerelle di conduzione metalliche per cavi Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 C 11 Installazione de
406. us 0 e il valore HSA almeno un indirizzo nella rete non sia occupato con il nodo di bus quindi sia presente al meno uno spazio vuoto di indirizzo Questo spazo libero di indirizzo pu essere ottenuto anche impostando semplicemente il valore del parametro HSA di almeno un unit in pi rispetto all indirizzo di bus per il nodo pi alto impostato nella rete Avvertenza Se non viene eseguita questa preimpostazione dopo una segmentazione la linea ottica non si chiude pi in un anello ottico ridondante Il messaggio di guasto LED e contatto di segnalazione dei due OLM interessati non viene ripristinato anche dopo l eliminazione del guasto Aumento del valore retry a min 3 Se si verifica un caso di ridondanza p es cavo spezzato subentra un tempo di commutazione durante il quale non possibile una trasmissione corretta dei dati Per garantire un esecuzione corretta dell applicazione si consiglia di impostare per il master PROFIBUS il numero di ripetizioni del telegramma retry a min 3 Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 27 Progettazione di reti Controllo e adattamento del tempo di slot 3 28 Per garantire una ricommutazione senza problemi della linea in un anello ottico dopo l eliminazione del disturbo in questo momento nella rete non deve trovarsi nessun telegramma La rete per breve tempo libera da telegrammi se un master interroga un appparecchio l indirizzo del quale p
407. usgange Mounting of not used ports ert gt Ein nicht benutzter Ausgang wird mit Mutter 3 Dichtung 4 Dichtscheibe 7 Schirmkontaktier element 5 und Litzenhalter 6 abgeschlossen Reihenfolge beachten A not used port can be closed with nut 3 seal 4 sealing disk 7 shield contacting element 5 and strand holder 6 Pay attention to the order Montage auf Flache oder Hutschiene Mounting on a flat surface or on a hat rail Zur Montage auf einer ebenen Flache oder auf einer Hutschiene den fertig montierten SpliTConnect Tap 1 auf den SpliTConnect Clip 8 aufstecken For mounting on a flat surface or on a hat rail insert the completely assembled SpliTConnect Tap 1 into the SpliTConnect Clip 8 Hinweis Der SpliTConnect Tap dient nicht als Zugentlastung fur die PROFIBUS Leitung Die Leitung mu daher zugentlastet angebracht werden Note The SpliTConnect Tap is not a strain relieve for the PROFIBUS cable Therefore the cable has to be mounted strain relieved Copyright 1999 Siemens AG Montageanleitung f r SIMATIC NET PROFIBUS SpliTConnect System Mounting Instruction for SIMATIC NET PROFIBUS SpliTConnect System Zubeh r nicht im Lieferumfang enthalten Accessoires not included in scope of delivery Typ Type Beschreibung Description SpliTConnect Coupler Zur Kopplung zweier oder mehrerer SpliTConnect Tap For coupling of two or more SpliTConnect Tap Bes
408. ve Collegamento punto a multipunto 2 14 In caso di utilizzo di pi ILM essi devono essere posizionati in modo che si trovino nel fascio conico di raggi infrarossi di un altro ILM posto di fronte Possono scambiare dati tra di loro solo gli ILM che si trovano di fronte tra di loro Lo scambio di dati tra ILM monati uno di fianco all altro possibile solo deviando i raggi infrarossi di una superficie riflettente In questo caso va osservato che la lunghezza della linea viene formata dal percorso tra l ILM e il riflettore e da qui all ILM partner Inoltre si verifica un indebolimento del segnale in quanto il riflettore pu deviare realmente all ILM partner solo una parte dei raggi infrarossi Perdite di questo tipo comportano una riduzione della linea massima realizzabile Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS Master S7 400 D Linea di trasmissione 2 a raggi infrarossi 1 0 5 15m Master PG PC OP Segmento di rete slave PROFIBUS 1 Linea di trasmissione a raggi infrarossi 2 Slave 0 5 15m ET 200M Segmento di rete slave PROFIBUS 2 Linea di trasmissione a raggi infrarossi 3 0 5 15m Resistenza terminale attivata Segmento di rete 2 Cavo di bus PROFIBUS slave PROFI
409. vi di bus al di fuori degli edifici Figura C 1 Protezione meccanica del cavo di bus tramite montaggio protetto Reti PROFIBUS SIMATIC NET C 4 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Installazione dei cavi di bus Figura C 2 Interruzione del tubo di protezione su un giunto di dilatazione Bus terminal RS 485 L installazione di cavi di bus elettrici in una zona sicura viene supportata impie gando i bus terminal RS 485 Essi permettono l allacciamento di terminali di dati e gli interventi di service e messa in funzione su terminali di dati senza che il cavo di bus vero e proprio debba essere spostato Cavi di bus ridondanti Per l installazione di cavi di bus ridondanti sono necessari alcuni requisiti cavi ridondanti devono essere sempre installati in tracciati separati per escludere danni contemporanei dovuti allo stesso evento Non piegare o schiacciare cavi da trascinamento e a festoni In caso di impiego di cavi da trascinamento o di cavi a festoni per parti in movi mento necessario garantire misure adatte che impediscano la piega o lo schiac ciamento dei cavi dovuti ad altri cavi o parti della costruzione durante il movimento Non utilizzare cavi da trascinamento e a festoni attorcigliati Per mantenere la durata del cavo da trascinamento e a festoni essi devono es sere installati senza torsioni Una linea continua stampata in direzione longitudinale sulla guaina esterna ne permette il controllo Reti PROFIBUS
410. via the infrared link The receive level is compared with a fixed reference value If the level falls below this reference value during reception the red LOW LED is always lit With suitable configuration the user can also trigger the signaling contact in this situation The reference value corresponds to 1 4 x the minimum receive level This situation 1 4 x the minimum receive level applies when the distance between the sending and receiving PROFIBUS ILM is 80 to 85 of the maximum distance in this direction In the optical axis receiver and sender are directly opposite and turned through exactly 180 degrees to each other the maximum distance is 15 m in other words at approximately 12 m to 13 m between the sending and receiving PROFIBUS ILMs the received optical level is still 1 4 times the minimum receive level A reserve of 2 to 3 m remains along the optical axis This reserve is however drastically reduced if the position of one of the PROFIBUS ILMs is changed in such a way that it is moved out of the optical axis if the PROFIBUS ILM is moved sideways or turned When close together a displacement of only a few centimeters vertically away from the optical axis can lead not only to the level monitoring responding but also to errors on the bus 5 5 Constant Light Monitoring To transmit data the PROFIBUS ILM uses infrared light as emitted by other energy sources If the received light exceeds a certain intensity the working range of
411. vo dati e schermo Cavo spezzato Schermo interrotto Scambio dei cavi A e B Influssi che possono comportare guasti Controllo del numero delle resistenze terminali inserite Inoltre possibile determinare la lunghezza del cavo PROFIBUS installato Controllo dell interfaccia RS485 di uno slave Per questa operazione il dispositivo di test viene allacciato esattamente ad uno slave Questo slave viene alimentato Il dispositivo di test esegue le seguenti misurazioni Driver RS 485 o k difettoso Tensione di alimentazione per terminazione del cavo in ordine non in ordine Segnale RTS esistente inesistente Controllo della raggiungibilit dei nodi A 4 Registrazione degli slave raggiungibili Live List Interrogazione mirata dei singoli slave Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 TECNICA DI MISURA PROFIBUS A 1 6 Tipo di funzionamento Misurazioni del cavo test e le misurazioni descritti precedentemente si basano sostanzialmente a misurazioni di tensione riflessione e resistenza Per il controllo del cavo il misuratore viene innestato su un estremit del cavo e sull altra estremit viene collegato un connettore di test Durante il montaggio del cavo l utente passa in successione da connettore a connettore Le misurazioni vengono successivamente eseguite automaticamente premendo il pulsante e i risultati vengono visualizzati Misurazione sul nodo Per la misurazione sul nodo ste
412. zioni gt Cavi Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 3 25 Progettazione di reti Controllo dei parametri del bus Il tool di progettazione controlla a causa delle immissioni se il tempo di slot pu essere mantenuto nel profilo di comunicazione selezionato In caso di supera mento di questo valore dovuto a tempi di transito supplementari di OLM e cavi FO viene eseguito un adattamento dei parametri nuovi parametri del bus calco lati possono essere rilevati dalla finestra Parametri del bus Parametri del bus HUGYO Calcala Figura 3 6 Parametri del bus adattati all impianto Reti PROFIBUS SIMATIC NET 3 26 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Progettazione di reti 3 3 2 Progettazione di anelli ottici ridondanti con OLM Nell anello ottico ridondante necessario creare le seguenti condizioni di progetta zione 1 Progettazione di un nodo di bus non disponibile 2 Aumento del valore retry a min 3 3 Controllo e adattamento del tempo di slot Per impostare i parametri riportati al punto 2 e 3 impiegare il profilo specifico per l utente del tool di progettazione Alla fine di questo capitolo si trova un esempio per l assunzione dei parametri del bus riportati in STEP 7 Progettazione di un nodo di bus non disponibile Per tutti i terminali di dati il valore del parametro HSA Highest Station Adress deve essere impostato in modo che tra l indirizzo di b
413. zza delle persone e alla prevenzione di danni materiali che vanno assolutamente osservate Le avvertenze sono contrassegnate da un trian golo e a seconda del grado di pericolo rappresentate nel modo seguente Pericolo di morte significa che la non osservanza delle relative misure di sicurezza provoca la morte gravi lesioni alle persone e ingenti danni materiali Pericolo significa che la non osservanza delle relative misure di sicurezza pu causare la morte gravi lesioni alle persone e ingenti danni materiali Attenzione significa che la non osservanza delle relative misure di sicurezza pu causare leggere lesioni alle per sone o lievi danni materiali Avvertenza un informazione importante sul prodotto sull uso dello stesso o su quelle parti della documentazione a cui si deve prestare una particolare attenzione Personale qualificato La messa in servizio e il funzionamento di un dispositivo devono essere eseguiti esclusivamente da per sonalequalificato Personale qualificato ai sensi delle avvertenze di sicurezza contenute nella presente documentazione quello che dispone della qualifica a inserire mettere a terra e contrassegnare secondo gli standard della tecnica di sicurezza apparecchi sistemi e circuiti elettrici Uso conforme alle disposizioni Pericolo Osservare quanto segue Il dispositivo deve essere impiegato solo per l uso previsto nel catalogo e nella documentazione
414. zza massima ammessa del cavo di derivazione riportata nella tabella 2 2 Osservare anche la lunghezza massima della somma dei cavi vedere sopra Reti PROFIBUS SIMATIC_NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS 2 18 Tabella 2 2 Lunghezza del cavo di derivazione per accoppiatore DP PA Numero dei cavi di deriva Lunghezza massima del cavo di derivazione zione Accoppiatore DP PA Accoppiatore DP PA Ex i da1a 12 max 120 m max 30 m da 13 a 14 max 90 m max 30 m da 15 a 18 max 60 m max 30 m da 19 a 24 max 30 m max 30 m Reti PROFIBUS SIMATIC NET 6GK1970 5CA20 0AA4 Edizione 2 05 2000 Topologie delle reti SIMATIC NET PROFIBUS 2 5 Accoppiamento ad altra rete 2 5 1 Accoppiatore DP PA Settore d impiego L accoppiatore PROFIBUS DP DP serve a collegare tra loro due reti PROFIBUS DP Vengono trasmessi dati byte 0 244 byte dal master DP della prima rete al master DP di un ulteriore rete e viceversa Il principio corrisponde all attuale cablaggio hardware di ingressi e uscite L accop piatore dispone di due interfacce DP indipendenti tra di loro con le quali viene ese guito l accoppiamento ad entrambe le reti DP L accoppiatore DP DP rappresenta rispettivamente uno slave sulla rete DP Lo scambio dei dati tra le due reti DP viene eseguito tramite copia da un interfaccia all altra nell accoppiatore 24V Error DP1 4