Home

MNPG05-08 _Man. multilingua T-ONE EVO I_II ITA-ENG-FRA

image

Contents

1. Disposal To protect the environment the device and its accessories must be disposed of in accordance with the law in areas equipped for that purpose or as special waste cz Product subject to WEEE regulations conceming separate waste collection when disposing this product please use the designated areas for disposing electronic waste or contact the manufacturer 10 Electrostimulation and stimulation intensity Electrostimulation consists of the transmission of electric microimpulses to the human body Fields of application of electrostimulation are pain therapy recovery of muscle trophism after injury or a surgical operation athletic preparation and beauty treatments Specific electric impulses are used for every one of these applications The stimulation intensity is displayed on the T ONE screen for each channel in a scale progressing from 0 to 120 Once the initial intensity has been set T ONE will proceed until it reaches the end of the phase when more than one phase is present the intensity has to be set again at the beginning of new phase The types of impulses can be classified as follows 1 Tens impulse for tens programs the intensity should be adjusted to a level between the thresholds of perception and pain The maximum limit is reached when the muscles surrounding the area treated begin to contract We recommend to stay below that limit IACER SRL MNPGO5 08 Ed 12 10 10 Pag 37 ll MEDICAL DIVISION 2 L
2. Pag 60 Description des commandes Instructions pr liminaires Mode op ratoire 6 Recharge des piles Pag 62 7 Entretien et conservation de T ONE Pag 63 8 R solution de probl mes Pag 63 9 Electrostimulation et intensit de stimulation Pag 64 10 Programmes SPORT Pag 65 11 Programmes BEAUTY Pag 69 12 Programmes T E N S Pag 73 13 Mise en marche Pag 78 14 Electrodes adh sives Pag 78 15 D claration de Conformit Pag 79 16 Caract ristiques techniques Pag 79 17 Assistance Pag 80 IACER SRL 05 08 Ed 12 10 10 Pag 56 1 Contenu du kit T ONE T ONE EVO I 11 Programmi Sport 9 Programmi Beauty 5 Programmi TENS T ONE EVO Il 11 Programmi Sport 9 Programmi Beauty 16 Programmi TENS n 1 lectrostimulateur T ONE n 4 c bles de raccordement pour la transmission des impulsions lectriques n 2 sets de 4 lectrodes autocollantes 41x41mm d enduites de gel 1 pour T ONE EVO 1 n 2 sets de 4 lectrodes autocollantes 40x80mm d j enduites de gel 1 pour T ONE EVO Il n 1 boite de 8 lectrodes autocollantes pour le visage d j enduites de gel seulement pour T ONE EVO II n 1 chargeur de piles n 1 mode d emploi T ONE n 1 Manuel des positions des lectrodes Les accessoires suivants sont disponibles l achat s par ment e Electrodes autocollantes 41x41mm 48X48mm 40x80mm 50x90mm visage diam 32mm Bandes lastiques conductrices pour les cuisses et
3. Prodotto conforme ai requisiti essenziali relativi alla Direttiva 93 42 CEE Dispositivi 0476 Medici 1 Apparecchio con alimentazione interna con parti applicate di tipo BF Apparecchio di classe Sensibilit alle scariche elettrostatiche ESD P a Prodotto soggetto alla normativa RAEE relativa alla raccolta differenziata Leggere attentamente le istruzioni d uso prima della messa in esercizio del dispositivo Pulsante di accensione e spegnimento Tasti multifunzione selezione programmi e gruppi muscolari CET Tasti multifunzione selezione campo di applicazione uomo donna salto fase Avvia Interrompe il programma selezionato conferma selezione pausa Tasto aumento intensita corrente in uscita Tasto diminuzione intensita corrente in uscita 6 Guida all uso di T ONE Descrizione dei comandi Avvio e arresto progamma FTF i Display LCD conferma gratico selezione Selezione Accensione M programmie Spegnimento gruppi muscolari Selezione campi di applicazione io n uomo donna Selezione campi di applicazione uomo donna e salto fase Aumenta intensit canale Diminuisce intensit canale Uscita canale 1 cavo blu Uscita canale 4 gt ch2 ch3 4 cavo bianco A 4 Uscita canale 2 i Uscita canale 3 cavo giallo Cavo rosso IACER SRL MNPG05 08 Ed 12 10 10 Pag 5 E
4. SA io EVO EVO Il Manuale utente User Manual Mode d emploi 05 rev 8 12 10 2010 LA C E R Srl Via 5 Pertini 24 30030 Martellago VE Italy Tel 39 041 5401356 Fax 39 041 5402684 e mail iacer iacer it http www iacer ve it Manuale utente ATTENZIONE T ONE E UN DISPOSITIVO MEDICO In presenza di qualsiasi problema di salute utilizzare T ONE solo dopo aver consultato il proprio medico Leggere attentamente il manuale utente prima di utilizzare T ONE Prima di utilizzare i programmi medicali leggere attentamente le controindicazioni e le avvertenze Prodotto da IACER S r l via Pertini 24 A 30030 Martellago Venezia Tel 041 5401356 Fax 041 5402684 e mail iacer iacer it IACER SRL MNPGO5 08 Ed 12 10 10 Pag 1 INDICE MANUALE UTENTE 1 Presentazione Pag 3 2 Contenuto del kit Pag 3 3 Destinazione d uso Pag 3 Controindicazioni ed effetti collaterali 4 Avvertenze Pag 4 5 Legenda simboli posti su T ONE e nel manuale Pag 5 6 Guida all uso di T ONE Pag 5 Descrizione dei comandi Istruzioni preliminari Istruzioni operative 7 Ricarica delle batterie Pag 8 8 Manutenzione e conservazione di T ONE Pag 9 9 Risoluzione di problemi e quesiti Pag 9 10 Elettrostimolazione ed intensita di stimolazione con T ONE Pag 10 11 Programmi Sport Pag 11 12 Programmi Beauty Pag 15 13 Programmi T E N S Pag 18 14 Impostazioni SETUP Pag 24 Selezione della lingua e
5. Il n existe pas de limites proprement dites l application de ces programmes qui peuvent tre ex cut s jusqu ce que l on obtienne le r sultat voulu L intensit de stimulation doit tre r gl e de fa on assurer de bonnes contractions musculaires pendant le traitement mais elle ne doit pas provoquer d endolorissement 20 30mA Normalement on constate les premiers r sultats au bout de 3 ou 4 semaines raison de 4 5 s ances par semaine E09 Drainage Temps total du programme 25 minutes Groupes Ce programme concerne tous les muscles que l on veut stimuler en s rie Brancher un canal pour musculaires chaque muscle en tenant compte du fait que les contractions s enchainent sur les 4 canaux Phase 1 Phase 2 Phase 3 Phase 4 a 10 minutes de contractions 10 minutes de contractions s 3 min chauffement m m 2 min d fatiguant en s rie sur les 4 canaux en s rie sur les 4 canaux 12 Programmes T E N S N ATTENTION Il convient de rappeler que l lectrostimulateur est un formidable outil anti douleur et que la douleur est un indicateur de maladies de toutes sortes Les programmes du pr sent paragraphe de T1 T18 sont pr d finis pour lutter contre la douleur On recommande de lire attentivement le mode d emploi avant d utiliser T ONE NE PAS OUBLIER QUE LA DOULEUR EST UN SIGNAL avant d utiliser T ONE d terminer la maladie en faisant appel son m decin TENS une abr
6. LW buttons Arms male trunk Legs male Arms female trunk Legs female male female 6 press to start program the display shows connect cables and electrodes and increase intensity of the used channels to start intensity press tor each used channel T ONE will begin the session 7 press the button for each use channel to increase current intensity until the personal tolerance level is reached IACER SRL MNPGO5 08 Ed 12 10 10 Pag 34 I TECH Selected Total Phases Battery charge program working phase Phase countdown indicator Working BE HERO OO Recovery work program 15 00 indicator bar Endurance Output nn RN connection error Wer ing aon p A OFF pis va V X Channel off mA The picture above is only used as demonstration and it not represent exactly the specifications of program S10 Endurance A bar indicating the start and end of a contraction will appear on the display whilst the electronic stimulator is working The periods of muscular contraction bold bar and the periods of recovery striped bar are graphically visualised under the bar with a cursor This enables the user to know exactly when a contractions starts Hi T emm 8 At the end of the first phase the T ONE cancels the previously selected intensity and warns the user with an intermittent signal to continue with the program press the A button for the relevant channels again until you reach the desired level of sti
7. 7 Ricarica della batteria Quando durante il funzionamento l apparecchio si spegne oppure l indicatore di carica batteria posto in lato a destra del display segna una sola delle tre tacche mettere in carica T ONE per circa 8 ore Dopo 8 10 ore di ricarica togliere il caricabatteria e staccarlo dalla presa domestica Caratteristiche caricabatteria sono riportate sull etichetta del caricabatteria Utilizzare caricabatterie forniti esclusivamente dalla ditta costruttrice o dal rivenditore autorizzato L uso di altri caricabatterie pu compromettere seriamente la sicurezza dell intero apparato e dell utilizzatore In caso di guasto utilizzare solo batterie del tipo fornito in dotazione Ni Mh ricaricabili da 4 8V stilo AA 1600 mAh L impiego di altri tipi di batterie ricaricabili pu causare malfunzionamento o danneggiamento dell apparecchio Per danni dovuti ad un impiego di batterie non adeguate il produttore non si assume nessuna responsabilit Non immergere la batteria nell acqua o in altri liquidi e non esporla a fonti di calore Non gettare batterie vecchie o difettose nei rifiuti domestici per lo smaltimento utilizzare gli appositi contenitori IMPORTANTE non lasciare la batteria scarica all interno di T ONE per lungo tempo Prima di mettere a dimora T ONE per lunghi periodi raccomandiamo di ricaricare la batteria e riporre l apparecchio in un luogo asciutto Operazione di ricarica e Inserire la spina del caricabatte
8. conseill d utiliser le dispositif T ONE et d autres dispositifs m dicaux en m me temps est d conseill d utiliser le dispositif en pr sence de substances inflammables ou dans les lieux forte concentration d oxyg ne En cas de pi ces m talliques d ost osynth se consulter un m decin avant d utiliser T ONE En cas d utilisation prolong e il est possible de ressentir une sensation de pesanteur musculaire et m me des crampes Dans ce cas il est recommand de suspendre l entrainement avec T ONE pour quelques jours et de le reprendre avec les programmes r cup ration musculaire et capillarisation S assurer que la fiche et le boitier du chargeur sont en parfait tat Si cela n tait pas le cas suspendre imm diatement l usage du chargeur et contacter le vendeur ou le fabricant N utiliser que les piles fournies par le fabricant l utilisation de chargeurs non fournis par le fabricant d gage la responsabilit de ce dernier en ce qui concerne les dommages provoqu s l appareil ou l utilisateur est interdit de placer les lectrodes de telle sorte que le flux de courant traverse l aire cardiaque ex une lectrode noire sur la poitrine et une lectrode rouge sur les omoplates mais il est galement permis de placer les lectrodes le long des chefs musculaires dans la zone cardiaque comme pour renforcer les pectoraux Il est interdit d utiliser l appareil avec des lectrodes plac es sur ou proxi
9. to a level between the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin to contract over this limit stimulation does not become more effective just more irritating so it is best to stop before that point The first benefits can be seen after 15 to 20 treatments carried out on a daily basis proceed with the treatment until the symptoms pass Program duration 30 minutes Position of electrodes see photo 28 in the manual of positions A09 Distortion Contusion Sprains Bruises Medical program only on T ONE EVO II The program develops its effectiveness after this type of injury by inhibiting pain locally producing three selectively acting differentiated impulses The intensity should be adjusted to a level between the thresholds of perception and pain Number of treatments until pain is lessened on a daily basis even 2 3 times a day Electrodes Positioning ankle photo 32 Phase 1 Phase 2 Tens rapid 15 min Haematomas impulse 15 min A10 Inflammatory Medical program only on T ONE EVO II Program recommended for inflammatory conditions To be applied until the inflammatory state is lessened 10 15 applications once a day the daily treatments can be doubled if required Identify the area to be treated and position the electrodes as shown in illustration 1 Adjust the intensity until a tingling feeling is produced in the
10. un effort intense et am liorer son oxyg nation L indication de base pour obtenir les premiers r sultats est la suivante deux s ances par semaine par groupe musculaire pendant les trois premi res semaines o l intensit est croissante 20 30mA trois s ances par semaine pendant les trois semaines suivantes o l intensit est lev e 30 50 L intensit doit tre r gl e progressivement traitement apr s traitement sans fatiguer excessivement les muscles En cas de fatigue interrompre les entrainements pendant quelques jours et effectuer le programme S02 r cup ration musculaire S06 Force Temps total du programme 30 minutes Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Be ae ee ae Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 3 Phase 4 10 min entrainement 10 min entrainement 5 min chauffement 13 sec r cup ration 14 sec r cup ration 5 min d fatiguant 7 sec contraction 6 sec contraction 507 Force Vitesse Ce programme a t tudi pour augmenter la vitesse chez les sportifs d j bien entra n s et la d velopper chez les autres L exercice a un ryt
11. voluntary contraction to reduce the sense of discomfort and reach higher intensities Intensity must be increased gradually treatment by treatment without overstraining the muscles Suspend training for a few days in the event of fatigue and proceed with the S 02 program During the second work phase the intensity level needs to be selected three times once for the four channels of active recovery once for contractions with channels 1 and 2 agonist muscles and once for contractions with channels 3 and 4 antagonist muscles S04 Agonist Antagonist Total duration 33 minutes Biceps brachii cH1 cH2 photo 02 Triceps cH3 cH4 photo 03 Hand extensors CH1 CH2 photo 04 Hand flexors cH3 cH4 photo 05 nu Quadriceps cH1 cH2 photo 11 Biceps femoris photo 12 Phase 1 2 3 IACER SRL 05 08 Ed 12 10 10 Pag 39 ll e MEDICAL DIVISION 20 min alternated contractions on 4 channels 6 sec Recovery cH1 2 3 4 Tsec contraction CH1 CH2 Tsec contraction CH3 CH4 3 min warm up 10 min recovery S05 Long effort resistant strength This program is designed to increase resistance to physical stress or rather withstand intense exertion for a longer amount of time in muscle regions subjected to stimulation Indicated for sporting disciplines involving long and intense periods of exertion Stimulation intensity during the contraction start with a low le
12. Solo per modello T ONE EVO II Questo programma lavora in maniera selettiva sulle fibre lente Ideale per il recupero del trofismo muscolare dopo un lungo periodo di inattivit o infortunio Programma da eseguire nel caso in cui la perdita del tono muscolare sia gi avvenuta Applicare con cautela intensit bassa sufficiente a produrre delle leggere contrazioni muscolari nelle prime 2 3 settimane Aumentare progressivamente l intensit nelle successive 3 4 settimane Applicazione a giorni alterni Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi A16 Atrofia Durata totale programma 30 minuti EA O Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore Ue AN NC ae d foto14 Fase 1 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 obliquo dell addome foto 22 anca foto 23 Fase 2 Fase 3 IACER SRL 05 08 Ed 12 10 10 Pag 23 Durata 25 min 6 sec di 6 sec contrazioni 3 min Riscaldamento 2 min Defaticante 14 Impostazioni SETUP Selezione della lingua e del contrasto display Premere il tasto di accensione e tenerlo premuto fino a che appare l elenco delle l
13. T ONE IACER SRL ram confirm E graphic LCD Select rams and muscles Switch OWOFF Select Sport Beau Tens program male female Select Sport Beauty Tens program male and female increase intensity Decresse intensity h Output CH1 chl ch2 ch ch4 match a Output Ch2 LL Output Ch3 MNPGO5 08 Ed 12 10 10 Pag 33 I TECH MEDICAL DIVISION Preliminary instructions Before using T ONE clean the skin of the area to be treated with the cable disconnected from T ONE connect the electrostimulation cable jacks to the self adhesive electrodes position the self adhesive electrodes on the skin see photos of electrode positions connect the impulse transmission cables to the relative jacks then turn T ONE on Warning make sure that T ONE is switched off before disconnecting the electrodes at the end of the treatment Operating instructions N B read the whole manual before using the equipment 1 Turn T ONE on using the button 2 Select the program group Sport Beauty Tens using the button 4 9 3 Select the program using the 2 LW buttons Riscaldamento Lipolisi Fecupero muscolare Capillarizzazione Tonificazione Agonista antagonista Definizione Modellamento Forza resistente Sport programs display Beauty programs display 4 4 Select male or female with d 9 buttons Female Male selection H selection 5 Select the muscle group with 4 amp 2
14. a dry place checking that it is switched off Do not use the battery charger if e The plug is damaged or parts of it are broken It has been exposed to rain or any other type of liquid e components have been damaged by a fall Do not immerge the battery charger in water Use a dry cloth to clean the battery charger Do not open the battery charger it does not contain repairable parts Warning disconnect electrodes during recharchig 8 T ONE maintenance and storage T ONE must be switched off and the cables removed from the connectors at the end of every session T ONE should be kept in the carry bag supplied together with its accessories and carefully stored on a secure surface and protected from situations listed in the Warnings paragraph T ONE should be stored in the following conditions Temperature from 20 to 406 Maximum relative humidity 75 Atmospheric pressure from 700 hPa to 1060 hPa Cleaning only clean the device using a dry soft cloth We recommend a functional test carried out by the manufacturer every 24 months The manufacturer retains that the T ONE device cannot be repaired by personnel external to its own company Any work of this nature carried out by personnel not authorised by the manufacturer will be classed as tampering with the device freeing the manufacturer from responsibility for the warranty and hazards that the operator or user may be exposed to N B disconnect the cabl
15. al rivenditore o al produttore di ci deve essere informato anche il paziente in trattamento presso un centro e Vietato l uso del dispositivo in combinazione con dispositivi medici e Vietato l uso del dispositivo in prossimit di sostanze infiammabili in ambienti con elevate concentrazioni di ossigeno e In caso di dispositivi metallici di osteosintesi consultare un medico prima dell uso di T ONE In caso di stimolazioni muscolari prolungate possibile riscontrare una sensazione di pesantezza muscolare In questi casi si consiglia di sospendere per qualche giorno i trattamenti con T ONE e di riprendere con i programmi recupero muscolare e capillarizzazione Porre attenzione all integrit della spina e dell involucro del caricabatteria Se risultano segni di deterioramento in una qualsiasi di queste parti sospendere immediatamente l uso del caricabatteria e contattare il rivenditore o il produttore e Vietato posizionare gli elettrodi in modo che il flusso della corrente attraversi l area cardiaca es un elettrodo nero sul petto e un elettrodo rosso sulle scapole altres consentito posizionare gli elettrodi lungo i fasci muscolari in area cardiaca come nel rafforzamento pettorali Vietato l uso del dispositivo con elettrodi posti sopra od in prossimit di lesioni o lacerazioni della cute e Vietato posizionare gli elettrodi su seni carotidei carotide genitali e Vietato posizionare gli elettrodi in prossimit de
16. and CH3 CH4 on the upper part e g thigh or biceps brachi Stimulation intensity this should be enough to produce a good level of stimulation without pain in the treated areas 15 30 mA Upper Hand extensors CH1 photo 04 with 2 electrodes Hand flexors CH2 photo 05 with 2 muscles electrodes biceps CH3 photo 02 with 2 electrodes Triceps CH4 photo 03 with 2 electrodes Lower Calves CH1 photo 13 con 2 elettrodi Anterior tibial CH2 photo 14 with 2 electrodes muscles Quadriceps CH3 photo 11 with 2 electrodes Bicipes femoris CH4 photo 12 with 2 electrodes Phase 1 Phase 2 Phase 3 20 min alternated contractions 6 sec recovery on 4 channels Tsec contraction CH1 CH2 Tsec contraction CH3 CH4 5 min warm up 5 min recovery E02 Refirming Indicated for firming up muscles working mainly on slow twitch fibres Suitable for those who have never done any physical activity or have been inactive for a long period of time Method of use 1 identify the muscle to be treated To obtain good results we suggest to treat just a few muscles at a time and complete the process described below 2 position the electrodes as shown in the photo 3 increase the intensity until the impulse can be felt use a low intensity for the first session to help you to understand how the machine works 4 during the program and over the next few days the intensity should be increased gradually so that muscle contractions
17. are not painful 5 during contraction generated by the unit contract the muscle voluntarily 6 acycle of 15 20 applications must be completed before the first results can be seen one application for each muscle every two days with a day of rest in between It is possible to work on pairs of muscles for example thighs and abdominal muscles treating thighs one day and abdominal the next day Working on too many muscles at the same time is not recommended IACER SRL 05 08 Ed 12 10 10 Pag 43 MEDICAL DIVISION E02 Refirming Total duration 30 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 H gu H ti Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 5 min warm up 13 sec recovery 13 sec recovery 5 min recovery 7 sec contraction 7 sec contraction E03 Tonification Indicated for toning up muscles working mainly on fast twitch fibres Suitable for people who already practice moderate physical activity Method of use 1 identify the muscle to be treated To obtain good results we suggest to treat just a few muscles at a time and complete the process described below 2 position the electr
18. area treated avoid contracting the surrounding muscles Program duration 30 minutes A11 Vascularization Medical program only on T ONE EVO II Has a vascularizing effect on the area treated Vascularization increases arterial flow and consequently aids the removal of algogenic substances and helps to restore normal physiological conditions Do not position the electrodes close to inflamed areas Daily application is recommended the number of applications is not defined the program can be used to reduce pain Stimulation intensity should be between the thresholds of perception and slight discomfort IACER SRL 05 08 Ed 12 10 10 Pag 49 Program duration 20 minutes Position of electrodes see photo 25 and 33 in the manual of positions 12 Decontracting only on T ONE EVO II Can be used for all sports after competitions or the most demanding training sessions in particular after long and intense exertion To be used immediately after exertion Helps drainage and capillarization improving muscle oxygenation and helping to discharge synthetic substances produced during exertion Program duration 35 minutes Stimulation intensity medium low increased during the last 10 minutes Position of electrodes see photos 01 to 20 in the manual of positions A12 Decontracting Total duration 35 minutes Electrodes Positioning form a square above the painful area as shown in illustration 1 Fase 1 Fase 2 Tens a impulso s
19. cavi siano connessi in maniera corretta connettore ben inserito T ONE si spegne durante funzionamento E consigliabile ricaricare le batterie e iniziare nuovamente il trattamento se ci non basta sostituire le batterie T ONE si accende ma sul display non appare alcuna scritta Aprire il vano batteria sollevare la batteria scollegare lo spinotto e rimuoverla All interno del vano batteria presente un piccolo foro con la scritta RESET infilare una piccola punta e premere con delicatezza Smaltimento Per la salvaguardia dell ambiente il dispositivo gli accessori e soprattutto le batterie vanno smaltiti facendo riferimento alle norme di legge in apposite aree attrezzate o tra i rifiuti speciali Prodotto soggetto alla normativa RAEE relativa alla raccolta differenziata per lo smaltimento del prodotto usare apposite aree attrezzate alla raccolta di materiale elettronico o contattare il produttore IACER SRL MNPGO5 08 Ed 12 10 10 Pag 9 10 Elettrostimolazione ed intensit di stimolazione L elettrostimolazione consiste nella trasmissione al corpo umano di microimpulsi elettrici localizzati generati con T ONE e condotti agli elettrodi applicati al corpo a mezzo dei cavi di connessione campi di applicazione dell elettrostimolazione sono terapia del dolore recupero del trofismo muscolare dopo traumi o interventi operatori preparazione atletica e trattamenti estetici Per ognuna di queste applicazioni s
20. che si desidera stimolare in sequenza Fase 1 2 3 4 IACER SRL MNPGO5 08 Ed 12 10 10 Pag 14 3 min Riscaldamento 10 min di contrazioni in sequenza sui 4 canali 10 min di contrazioni in sequenza sui 4 canali 2 min Defaticante della durata di 6 sec cad della durata di 6 sec cad 511 Contrazioni fasiche sequenziali Questo programma crea delle contrazioni ritmiche con una frequenza di stimolazione tipica delle fibre rapide Proprio per questa maggiore frequenza di stimolazione adatto per l aumento della forza in sequenza su pi muscoli programmi eseguono nella fase due e tre delle contrazioni fasiche sequenziali sui 4 canali Questi programmi possono essere eseguiti con l utilizzo degli elettrodi adesivi L intensit di stimolazione deve essere sufficiente a garantire delle buone contrazioni muscolari durante il trattamento ma tali da non produrre indolenzimento 20 40mA A differenza del precedente la frequenza di stimolazione usata nella fase di contrazione pi alta quindi privilegia un lavoro sulle fibre rapide Descrizione programma gruppi muscolari interessati con riferimento foto posizionamento elettrodi 511 Contrazioni fasiche Durata totale programma 25 minuti Gruppi muscolari tutti quelli che si desidera stimolare in sequenza Fase 1 Fase 2 Fase 3 Fase 4 3 min Riscaldamento 10 min di contrazioni in sequenza sui 4 canali della durata di 6
21. contraction jusqu conduire la charge de travail aux niveaux d intensit s conseill es dans la description de chaque programme Il est conseill en outre de noter les intensit s atteintes pour chercher am liorer le niveau de stimulation et en cons quence les prestations 4 Impulsion de massage de relaxation de r cup ration active l intensit devra tre r gl e progressivement en obtenant un massage du muscle trait est conseill de r gler l intensit sur des valeurs permettant d obtenir un massage tout fait confortable I faut tenir compte que dans ce cas il n est pas n cessaire de r sister des intensit s lev es parce qu il s agit d un massage par cons quent il sera possible de progresser graduellement avec une augmentation sans exc s de l intensit 5 Impulsion de diffusion capillaire augmenter progressivement l intensit jusqu produire une stimulation constante et visible de la zone trait e il est conseill d atteindre un seuil de stimulation moyen toujours en dessous du seuil de la douleur 6 Impulsion de lipolyse drainage l effet pompe est produit par des contractions toniques s quentielles L intensit doit tre suffisante pour produire ces contractions plus grande sera la contraction plus grand sera l effet pompe induit Mais attention il n est pas n cessaire de r sister des intensit s lev es qui provoquent des douleurs Il est conseill de r aliser les prem
22. described in this paragraph are analgesic You are advised to read the manual carefully before using T ONE REMEMBER THAT PAIN IS A SIGN consult a doctor to identify the medical condition before using T ONE TENS an acronym standing for transcutaneous electrical nerve stimulation is a therapeutic technique mainly used for analgesic purposes to counter the effects usually pain of a wide variety of medical conditions For this purpose it finds application in treating everyday ailments troubling mankind neck pain arthrosis myalgia neuritis back pain periarthritis heaviness in legs muscle weakness just to mention a few On an academic level TENS can be divided into various categories according to the mechanism used to reduce the pain The main types are conventional TENS or fast IACER SRL MNPGO5 08 Ed 12 10 10 Pag 46 analgesic electro acupuncture training TENS or delayed analgesic TENS at maximum values with antidromic action and consequently an immediate local anaesthetic effect The rehabilitative action of TENS is represented by its power to reduce pain thereby restoring physiological conditions this allows the patient to regain normal motor function Consider a patient suffering from irritating periarthritis they either resort to using analgesics or learn to live with the pain that often makes even the simplest movements impossible Immobility reduces metabolic activity making it impossible to eliminate a
23. es et pr tes tre utilis s Elles sont particuli rement indiqu es pour les traitements d lectrostimulation Leur grande flexibilit permet de les placer facilement pour le traitement des diverses zones Pour les utiliser retirer l lectrode du plastique sp cial qui la prot ge placer la sur la peau comme indiqu dans le mode d emploi et apr s l utilisation la rattacher au plastique La dur e d une lectrode est d termin e par le pH de la peau il est toutefois conseill de ne pas d passer les 10 15 applications avec la m me lectrode Une utilisation r p t e des m mes lectrodes peut compromettre la s curit de la stimulation pour cette raison leur utilisation est interdite quand l lectrode n adh re plus la peau cela peut entra ner en effet un rougissement cutan qui persiste quelques heures apr s la fin de la stimulation Dans ce cas consulter un m decin IACER SRL 05 08 Ed 12 10 10 Pag 78 15 D claration de conformit La soci t IACER S r l dont le si ge social se situe Via S Pertini 24 A 30030 Martellago VE d clare que l appareilles T ONE EVO I T ONE EVO II son fabriqu conform ment la Directive 93 42 CEE du Conseil du 14 juin 1993 relative aux dispositifs m dicaux D L 46 97 du 24 f vrier 1997 Mise en uvre de la Directive 93 42 CEE relative aux dispositifs m dicaux annexe Il et au Directeur 2007 47 CE de Septembre 5th 2007 D Lgs 37 2010 de Janvier 25t
24. human body This energy modulated in accordance with parameters typical to each impulse can be used for various purposes from pain reduction to winding down exercises from muscle strengthening to drainage from isotonic exercises to treating haematomas to the treatment of imperfections using the beauty programs The manufacturer recommend to consult your doctor before using TENS programs Contraindications This device must not be used by people with a pace maker epileptics pregnant women people with a high temperature anxious people or people suffering from heart disease phlebitis thrombophlebitis or serious illnesses In the event of injury muscle stress or any other health problem consult your doctor before using the device and only use it under medical supervision Side effects No significant side effects are known of Some particularly sensitive people have reported skin redness in the area where the electrodes were positioned the redness usually disappears a few minutes after the end of the treatment Should the redness persist please consult a doctor In rare cases stimulation carried out in the evening can cause some people to experience difficulty in falling asleep If this occurs suspend the treatment and consult a doctor IACER SRL MNPGO5 08 Ed 12 10 10 Pag 31 4 Warnings T ONE has been designed and manufactured to be operated exclusively with the internal rechargeable battery T ONE doesn t produce and do
25. interessati con riferimento foto posizionamento elettrodi S07 Forza veloce Durata totale programma 26 minuti Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 Ue AN ee ae d Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 Fase 4 10 min Allenamento 8 min Allenamento 3 min Riscaldamento 14 sec recupero 10 sec recupero 5 min Defaticante 6 sec contrazione 5 sec contrazione S08 Forza esplosiva programmi di forza esplosiva favoriscono l aumento della capacit esplosiva e di velocit della massa muscolare con contrazioni di rafforzamento estremamente brevi e recupero attivo molto lungo per permettere al muscolo un recupero dello sforzo Normalmente bene aver concluso un ciclo di tre settimane di forza base ad intensit crescente Continuare poi con tre settimane di forza esplosiva due volte a settimana L intensit durante la contrazione deve essere la massima sopportabile al fine di far eseguire alla muscolatura il massimo sforzo reclutando al contempo il maggior numero di fibre superiore ai 35mA IACER SRL MNPG05 08 Ed 12 10 10 Pag 13 Descrizione programmi gruppi muscolari interessati con riferimento foto p
26. l effort Peut tre utilis apr s tous les sports que ce soit apr s une comp tition ou un entrainement en particulier apr s des efforts longs et intenses A utiliser imm diatement apr s l effort Gr ce ce programme le muscle sera pr t rapidement pour une nouvelle s ance d entrainement ou une comp tition Dur e du programme 15 minutes Intensit de stimulation moyenne basse 15 20 mA de fa on obtenir des secousses musculaires visibles Augmenter progressivement l intensit pour obtenir un massage vigoureux Rester en dessous du seuil de contraction musculaire Position des lectrodes voir photos 1 20 du manuel E09 Drainage R alis s pour favoriser les processus d limination ces programmes augmentent la micro circulation l int rieur et l ext rieur des fibres musculaires trait es en cr ant par ailleurs des contractions rythmiques en facilitant le d bit des substances algiques et en favorisant l activit lymphatique Ils peuvent tre appliqu s galement des personnes d un certain ge pour am liorer la circulation sanguine et lymphatique IACER SRL 05 08 Ed 12 10 10 Pag 72 Au cours des phases 2 et 3 ces programmes ex cutent des contractions toniques s quentielles capables de reproduire l effet typique du drainage lectronique lymphatique Dans ce cas cependant contrairement au programme lipolyse les contractions sont s quentielles tout d abord CH1 puis CH2 CH3
27. les programmes Sport et Beaut l intensit varie selon le type de muscle ou de programme utilis nous sp cifions ci dessous la fa on de d terminer la bonne intensit en fonction de l impulsion utilis e Les types d impulsions peuvent tre divis s comme suit 1 Impulsion tens dans les programmes tens l intensit est r gl e entre le seuil de perception et le seuil de la douleur La limite maximale est atteinte au moment o la musculature autour de la zone trait e commence se contracter Il est conseill de rester en dessous de cette limite 2 Impulsion d chauffement dans ce cas il sera n cessaire de produire une stimulation avec une intensit croissance progressive de mani re augmenter graduellement le m tabolisme du muscle trait C est un peu ce qui ce passe avec une voiture avant de la porter au r gime maximal il faut chauffer le moteur 3 Impulsion de contraction tonifiante d entrainement d atrophie pendant l impulsion d entrainement le muscle devra produire des contractions importantes On remarquera aussi l oeil nu comment le muscle tend se rigidifier et augmenter de volume Il est conseill d augmenter l intensit progressivement au cours de la premi re contraction pour trouver un juste confort de stimulation Pendant la seconde contraction d entra nement l intensit sera de nouveau augment e jusqu au seuil suggestif d endurance cette op ration sera r p t e de contraction en
28. quadriceps et les muscles antagonistes du biceps f moral ou du biceps brachial et du triceps Ce type de travail vise d velopper la force Dans la phase 2 de travail il faut s lectionner trois fois l intensit celle sur les 4 canaux pour la r cup ration active celle sur les canaux 1 et 2 pour la contraction des muscles agonistes et celle sur les canaux 3 et 4 pour la contraction des muscles antagonistes Intensit de la stimulation durant la contraction suivre les indications mentionn es au d but du chapitre concernant les programmes Sport L intensit doit tre r gl e progressivement traitement apr s traitement sans fatiguer excessivement les muscles En cas de fatigue interrompre les entrainements pendant quelques jours et effectuer le programme S02 r cup ration musculaire S04 Muscles agonistes Muscles antagonistes SIS Temps total du programme 33 minutes Biceps cH1 cH2 photo 02 Triceps photo 03 Extenseurs de la main cH1 cH2 photo 04 Fl chisseurs de la main cH3 CH4 photo 05 H Hi Quadriceps cH1 cH2 photo 11 Biceps cruraux cH3 cH4 photo 12 Phase 1 Phase 2 20 min des contractions alternatives sur couple canaux 6 sec r cup ration 7 sec contraction CH1 CH2 7 sec contraction CH3 CH4 Phase 3 3 min chauffement 10 min d fatiguant 505 R sistance Ce programme a t tudi pour d velopper la r sistance l ef
29. recovering from an accident or an operation Prevents muscle atrophy caused by physical inactivity The muscle area concerned can be stimulated with daily applications of medium intensity if you increase the intensity leave a day of rest between applications to allow the muscles to recover The intensity of this program must be adjusted to produce during second phase good muscle contraction in the area treated Position of electrodes from photo 1 to photo 20 Program duration 30 minutes A15 Atrophy prevention Total duration 30 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 IACER SRL 05 08 Ed 12 10 10 Pag 50 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 H LE Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 5 min warm up 9 sec recovery 9 sec recovery 5 min recovery 6 sec contraction 6 sec contraction A16 Atrophy trophism rehabilitation Medical program only on T ONE EVO Il This program acts selectively on slow twitch fibres Ideal for recovering muscle trophism after a long period of inactivity or an accident Program to be carried out when loss of muscle tone has already occurred Apply with caution at low intensity enough t
30. riduzione del dolore TENS convenzionale o antalgico rapido TENS training tipo elettroagopuntura o antalgico ritardato TENS a scansione dove vengono variati i parametri di stimolazione durante il trattamento TENS ai valori massimi con azione antidromica e conseguente effetto anestetizzante locale immediato TENS burst che un mix dei primi due tipi di tens La funzione riabilitativa della TENS rappresentata dalla sua capacit di ridurre il dolore con conseguente ripristino delle condizioni fisiologiche il che consente al paziente di riprendere il pi delle volte una funzionalit motoria normale Pensiamo ad un paziente afflitto da una fastidiosa periartrite questi o ricorre all uso di analgesici oppure convive col dolore che il pi delle volte rende impraticabili anche i pi semplici movimenti L immobilit riduce l attivit metabolica con conseguente incapacit di eliminazione delle sostanze algogene Ecco attivato un circolo vizioso La TENS oltre a ridurre il dolore provoca una stimolazione indotta della muscolatura con aumento dell attivit metabolica maggior flusso sanguigno migliore ossigenazione dei tessuti con apporto di sostanze nutritizie Se dunque si combina TENS e stimolazione muscolare dell area interessata l effetto positivo sar amplificato Posizione elettrodi ed intensit Gli elettrodi vanno posti a quadrato circoscrivendo la zona dolente utilizzando il canale 1 e il canale 2 come in figura 1 il posizioname
31. s 15 20 traitements r alis s quotidiennement suivre le traitement jusqu la disparition des sympt mes Dur e du programme 30 minutes Position des lectrodes voir photo 28 du manuel des positions A09 Entorse programme m dicaux seulement T ONE EVO II Ce programme est particuli rement indiqu pour lutter contre la douleur car il exerce une action inhibitrice locale Intensit r gl e entre le seuil de sensibilit et le seuil douloureux Nombre de traitements jusqu ce que la douleur diminue raison de 1 par jour on peut en faire galement 2 ou 3 par jour Placement des lectrodes cheville photo 32 Phase 1 Phase 2 Tens Classique 15 minutes Tens impulsion pour H matomes 15 minutes A10 Anti inflammatoire programme m dicaux seulement T ONE EVO II Programme conseill pour les tats inflammatoires Application jusqu la diminution de l inflammation On peut faire galement deux applications cons cutives par jour Intensit r gl e juste au dessus du seuil de sensibilit Une fois d termin e la zone traiter placer les lectrodes conform ment au sch ma n 1 Dur e du programme 30 minutes en une seule phase 11 Vascularisation seulement T ONE EVO Ce programme produit un effet de vascularisation dans la zone trait e La vascularisation augmente le d bit art riel en entra nant l limination des substances algiques et en r tablissant les conditions ph
32. sec cad 10 min di contrazioni in sequenza sui 4 canali della durata di 6 sec cad 2 min Defaticante 12 Programmi Beauty E01 Lipolisi Programma ampiamente utilizzato in ambito estetico indicato per le zone che presentano accumuli di grasso agisce aumentando la microcircolazione sanguigna e favorendo l attivit linfatica Questo programma produce un apprezzabile aumento del metabolismo locale con azione trofica favorisce la riduzione del fastidioso effetto buccia d arancia Il tutto coadiuvato con un regime alimentare ipocalorico Il numero di applicazioni pu raggiungere la frequenza giornaliera Il programma produce nella fase centrale di lavoro contrazioni toniche in sequenza prima CH1 CH2 poi CH3 CH4 il prezioso drenaggio linfatico elettronico La logica dunque di applicazione degli elettrodi la seguente CH1 CH2 alle estremit degli arti es polpaccio o avambraccio e CH3 CH4 nella parte superiore es coscia o bicipite brachiale Intensit di stimolazione tale da produrre delle buone sollecitazioni non dolorose delle aree stimolate 15 30mA Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi E01 Lipolisi Durata totale programma 30 minuti Gruppi Estensori d mano CH1 foto 04 con 2 elettrodi Flessori d mano CH2 foto 05 con 2 elettrodi muscolari Bicipite brachiale CH3 foto 02 con 2 elettrodi Tricipite CH4 foto 03 con 2 e
33. un massage A03 TENS wobbul programme m dicaux L action de ce programme est pratiquement la m me que celle du programme 01 Durant la stimulation le nombre d impulsions et leur largeur varient afin d viter l accoutumance la IACER SRL MNPGO5 08 Ed 12 10 10 Pag 74 stimulation il ne sera pas n cessaire d augmenter continuellement l intensit S lectionner l intensit au d but du programme et la garder jusqu la fin se pourrait que durant le programme la sensibilit la stimulation diminue dans ce cas ne pas augmenter l intensit mais attendre la fin Le TENS remplit sa fonction Ce programme dure 20 minutes et il comprend une phase Intensit peine au dessus du seuil de sensibilit Placement des lectrodes en forme de carr sur la zone douloureuse conform ment au sch ma 1 ou en suivant le guide du placement des lectrodes de la photo n 25 la photo n 33 A04 TENS puissant programme m dicaux La dur e de ce programme est tr s br ve 3 minutes et une seule phase Il produit un blocage p riph rique des impulsions douloureuses en provoquant un v ritable effet anesth siant local Ce type de stimulation convient parfaitement pour les traumatismes ou les contusions o il est n cessaire d intervenir rapidement S lectionner l intensit maximale supportable bien au del de la limite du TENS Conventionnel et donc avec une contraction bien visible des muscles qui entourent la zon
34. viation pour Transcutaneous Electrical Nerve Stimulation est une technique th rapeutique utilis e essentiellement des fins analg siques pour soulager de douleurs puisant leurs sources dans diff rentes pathologies Cette technique s applique au traitement d une grande vari t de maladies fr quentes n vralgies arthrose myalgies n vrites mal de dos p riarthrite jambes lourdes pour en citer quelques unes Sur un plan acad mique le TENS se divise en plusieurs cat gories selon le m canisme utilis pour diminuer la douleur Les principaux types sont TENS conventionnel analg sique rapide TENS lectro acupuncture analg sique retard TENS s quences wobbul pendant lequel on fait varier les param tres de stimulation TENS valeurs maximales avec un effet local anesth siant imm diat TENS burst qui est un mix des deux premiers Le TENS a une action r ducatrice car en soulageant la douleur il permet de restaurer des conditions physiologiques normales cela permet au patient de retrouver ses fonctions motrices normales Par exemple un patient souffrant d une p riarthrite irritante prendra es antalgiques ou apprendra vivre avec des douleurs qui rendent parfois un simple mouvement impossible L immobilit r duit l activit m tabolique rendant impossible l limination de substances algog nes Donc un cercle visieux se met en place En plus de soulager des douleurs le TENS cr e une stimulation musculaire
35. 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 5 min 5 min warm up 13 sec recovery 14 sec recovery 5 min recovery 7 sec contraction 6 sec contraction E05 Limbs modelling Due to a combination of capillarizing and toning impulses this program helps mobilise fat in areas where it tends to accumulate The electrodes should be positioned to form a square around the limbs area and can be applied daily using a medium intensity Program duration 30 minutes one phase Recommended stimulation intensity medium Position of electrodes see photos 01 to 20 and photo 22 and 23 in the manual of positions E06 Microlifting The following program with a duration of 15 minutes is used to tone facial muscles using a special impulse to improve both the appearance and the dynamism of facial muscles The position of the electrodes is shown in the manual of electrode positions photo 24 N B a minimum distance of 3 cm must be kept between the electrode and the eyeball IMPORTANT take care when adjusting the intensity as facial muscles because they are particularly sensitive intensity should be increased gradually starting with a very low level of stimulation just above perception and increasing with care until a good level of stimulation is reached represented by good muscle activation A IMPORTANT it is not necessary to reach levels of in
36. 5 Prevenzione atrofia Programma medicale Solo per modello T ONE EVO II Programma ideato per il mantenimento del trofismo muscolare Durante tutto il trattamento viene privilegiato il lavoro di tonicit muscolare con particolare attenzione alle fibre lente Particolarmente indicato in persone reduci da un infortunio o post operati Contrasta la riduzione del trofismo muscolare per inattivit fisica Si pu stimolare la zona muscolare interessata con applicazioni quotidiane a bassa intensit se si aumenta l intensit bisogna consentire alla muscolatura di recuperare lasciando un giorno di riposo tra le applicazioni Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi A15 Prevenzione atrofia Durata totale programma 30 minuti O Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 D uu d Fase 1 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 obliquo dell addome foto 22 anca foto 23 Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 2 Fase 3 Fase 4 5 min Riscaldamento Durata 10 min 9 sec recupero 6 sec contrazione Durata 10 min 9 sec recupero 6 sec contrazione 5 min Defaticante 16 Atrofia Programma medicale
37. 5 minuti Posizione elettrodi formando un quadrato sopra la zona dolente come figura 1 Fase 1 Fase 2 Tens a impulso stretto 15 min Tens a impulso largo 20 min 13 Ematomi Programma medicale Solo per modello T ONE EVO II Consultare il medico prima di intervenire con questo programma sugli ematomi Durata totale del programma 20 minuti in una fase Poche applicazioni intervenendo entro poche ore dalla contusione Combinando diversi tipi di impulsi ad onda quadra si ottiene una azione drenante sulla zona da trattare di tipo scalare impulsi a frequenze diverse drenano la zona a profondita diverse Intensita regolata fra la soglia di percezione e la soglia del dolore Posizione elettrodi formando un quadrato sopra la zona da trattare come figura 1 14 Impulsi rigeneranti Programma medicale Solo per modello T ONE EVO Il Programma dotato di quattro fasi con tre impulsi differenziati capace di vascolarizzare e tonificare la muscolatura superficiale Svolge inoltre una azione antidolorifica locale Intensit regolata fra la soglia di percezione e la soglia del dolore Descrizione programma con riferimento posizione elettrodi IACER SRL MNPGO5 08 Ed 12 10 10 Pag 22 Posizione elettrodi formando un quadrato sopra la zona da trattare come figura 1 Fase 1 Fase 2 Fase 3 Fase 4 10 min 10 min 10 min 10 min Vascolarizzazione Tens ad impulso stretto Tens a scansione Vascolarizzazione 1
38. Attention dans le cas des lectrodes rondes et de celles de 35x45 mm il est possible pendant le traitement de d passer une densit de courant de 2mA cm pour chaque lectrode Dans ces cas porter une attention particuli re aux ventuelles rougeurs cutan es En cas de rougeurs cutan es qui persistent plusieurs heures apr s la fin du traitement suspendre les applications et consulter son m decin IACER SRL MNPGO5 08 Ed 12 10 10 Pag 58 4 Signification des symboles plac s sur T ONE et dans le manuel C E0476 00e HO e 07 IACER SRL Produit conforme la directive 93 42 CEE concernant des applications de type m dical Appareil alimentation int rieure avec des l ments appliqu s de type BF Appareil de Classe Il Sensibilit d charge lectrostatique Produits soumis la norme RAEE relative la r cup ration des d chets Lire attentivement le mode d emploi avant la mise en marche de l appareil Bouton d allumage et d extinction Touches fonctions multiples s lection des programmes et des groupes musculaires Touches fonctions multiples s lection du champ d application homme femme saut de phase Mise en marche arr t du programme s lectionn confirmation de la s lection et pause Touche pour augmenter l intensit du courant de sortie Touche pour diminuer l intensit du courant de sortie MNPGO5 08 Ed 12 10 10 Pag 59 I TECH MEDICAL DIVISION 5 G
39. H1 A CH2 A CH3 A CH4 Bleu Jaune Rouge Blanc Pour r gler simultan ment l intensit de tous les canaux utiliser les touches Augmente D ie Possibilit de sauter les phases en cours de programme on peut passer la phase suivante en appuyant sur la touche 6 Commande pause arr t programme en cours de programme en appuyant une fois sur la touche GD on arr te momentan ment son fonctionnement pour repartir en appuyant de nouveau sur la touche gt Pour interrompre le programme appuyer deux fois de suite sur la touche lt gt 6 Recharge des piles Indication sur l cran du niveau des piles CT Piles Piles partiellement Piles charg es charg es d charg es Pour l utilisation des piles se conformer ce qui suit n utiliser que des piles du type de celles fournies avec l appareil Ni Mh rechargeables 1600mAh 4 8V Le fabricant se d charge de toute responsabilit pour les dommages dus l emploi de piles non appropri es Utiliser exclusivement le chargeur fourni par le fabricant inclus dans l emballage Ne pas tremper les piles dans l eau ou dans d autres liquides et ne pas les exposer des Sources de chaleur Ne pas jeter les vieilles piles ou les piles d fectueuses dans les ordures m nag res mais utiliser des r cipients sp ciaux CARACTERISTIQUES DU CHARGEUR voir mode d emploi du chargeur N IMPORTANT ne pas laisser les piles d charg es l int rieur de T ONE pendant trop longte
40. MEDICAL DIVISION Istruzioni preliminari Prima di procedere nell uso di T ONE pulire la cute in prossimit della zona da trattare collegare le clips dei cavi di elettrostimolazione all elettrodo con cavo scollegato da T ONE posizionare gli elettrodi adesivi sulla cute vedere foto nel manuale posizionamento elettrodi collegare i cavi agli appositi spinotti quindi procedere con l accensione Attenzione prima di scollegare gli elettrodi spegnere T ONE Istruzioni operative N B leggere tutto il manuale prima dell uso 1 Accendere T ONE con il pulsante tenendolo premuto per almeno 1 secondo 2 Selezionare il campo di applicazione Sport Beauty Tens con i tasti d 3 Procedere alla scelta del programma desiderato con il tasti 4 amp 9 gt es 501 Riscaldamento Hiscaldamento Recupero muscolare Capillarizzazione Agonista antagonista Videata programmi Sport 30 00 mm Lipolisi Tonificazione Definizione Modellamento Videata programmi Beauty 4 procedere con la selezione uomo o donna conii tasti 4 9 Selezione Selezione uomo donna 5 Quindi selezionare il gruppo muscolare interessato con i tasti 4 amp 9 Gp arti superiori tronco arti inferiori arti superiori tronco arti inferiori uomo uomo uomo donna donna donna 6 Per iniziare il lavoro di stimolazione premere il tasto BD sullo schermo viene visualizzata la scritta posizionare sulla cute gli elettrodi collegare i c
41. Phase 2 Phase 3 Phase 4 10 min 10 min 3 min warm up 24 sec recovery 24 sec recovery 5 min recovery 6 sec contraction 5 sec contraction 509 Endurance The Endurance program is used in sports to increase muscle resistance acting mainly on slow twitch fibres Program indicated for endurance sports marathon runners cross country skiers ironman etc Program duration 34 minutes Stimulation intensity during the contraction if not particularly fit start with a low intensity then increase gradually For practised athletes the intensity used should be enough to produce visible muscle contractions In the event of muscle ache after stimulation use the Fitness 19 program muscle relaxant IACER SRL 05 08 Ed 12 10 10 Pag 41 IR E MEDICAL DIVISION S09 Endurance Durata totale programma 50 minuti Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 H gu H ti Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 20 min 20 min 5 min warm up 20 sec recovery 20 sec recovery 5 min recovery 10 sec contraction 10 sec contraction 510 Tonic contractions sequential This program increases microci
42. RTOLINA AZZURRA E CONSERVARE LA CARTOLINA VERDE IACER SRL 05 08 Ed 12 10 10 Pag 25 a cura dell acquirente per la convalida della garanzia dovr essere spedito al costruttore l apposito tagliando da compilare in tutte le sue parti e timbrato dal rivenditore tagliando azzurro di convalida della garanzia In caso di successivo intervento in garanzia l apparecchiatura va imballata in modo da evitare danni durante il trasporto e spedita al costruttore assieme a tutti gli accessori avendo cura di compilare in tutte le sue parti il tagliando di assistenza tagliando verde di assistenza Per avere diritto agli interventi in garanzia l acquirente dovr inviare l apparecchio munito di cartolina verde di garanzia firmata dal rivenditore unitamente alla ricevuta o fattura comprovante la corretta provenienza del prodotto e la data di acquisto Norme di garanzia 1 Per confermare la garanzia l acquirente dovr compilare il tagliando azzurro di convalida della garanzia e spedirlo con affrancatura al costruttore subito dopo l acquisto con il timbro del rivenditore 2 n caso di intervento in garanzia l acquirente dovr compilare il tagliando verde di assistenza in tutte le sue parti e spedirlo insieme all apparecchiatura al costruttore Dovr essere allegata la ricevuta fiscale o fattura d acquisto all atto della spedizione della merce 3 La durata della garanzia di anni 2 due sulle parti elettroniche La garanzia vien
43. Very short duration 3 minutes Blocks pain impulses peripherally creating a proper anaesthetising effect in the area treated This type of stimulation is suitable for injuries or bruises when rapid action is required The intensity selected is the maximum tolerable value well in excess of conventional tens and therefore with considerable contraction of the muscles surrounding the area treated That is the reason why such stimulation is undoubtedly the least tolerated but is extremely effective This type of stimulation is not recommended for particularly sensitive people and in any case the electrodes should not be positioned in sensitive areas such as the face and genitals or close to wounds Position of electrodes form a square above the painful area as shown in illustration 1 A05 TENS Burst Medical program This stimulation produces a training TENS effect by using the conventional TENS frequency Commonly used for pain therapy The action is similar to that of the endorphinic TENS program and the treatment time is 15 minutes for each phase Position of electrodes form a square above the painful area as shown in illustration 1 06 Cervical pain Medical program only on T ONE EVO II Specific program for the treatment of pain in the neck area The intensity should be adjusted to a level between the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin
44. aines de force de base une intensit croissante Ensuite il faut faire un cycle de trois semaines de force explosive raison de deux fois par semaine Durant la contraction l intensit doit tre r gl e jusqu au seuil de tol rance maximale afin que musculature fasse le maximum d effort en int ressant en m me temps le plus grand nombre de fibres sup rieure 35mA S08 Force explosive Temps total du programme 28 minutes Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Ve AN oe ae Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 3 Phase 4 10 min entrainement 10 min entrainement 3 min chauffement 24 sec r cup ration 24 sec r cup ration 5 min d fatiguant 6 sec contraction 6 sec contraction S09 Endurance Le programme Endurance est utilis dans le domaine sportif pour augmenter la capacit de r sistance musculaire en travaillant surtout sur les fibres lentes Programme indiqu pour les sportifs pratiquant un sport de r sistance marathoniens coureurs de fond ironmen etc Intensit de stimulation durant la contraction suivre les indications mentionn es au d but du pr sen
45. ale provoca su alcuni soggetti un ritardo nell addormentarsi In tale caso evitare il trattamento serale IACER SRL MNPGO5 08 Ed 12 10 10 Pag 3 ll 0 MEDICAL DIVISION 4 Avvertenze T ONE funziona con batteria interna ricaricabile Ni Mh 1600mAh 4 8V e L apparecchio non genera non riceve interferenze elettromagnetiche da altre apparecchiature E opportuno comunque usare l apparecchio tenendo l applicatore distanza di almeno 3 metri da televisori monitor telefoni cellulari o qualsiasi altra apparecchiatura elettronica e Vietato l uso del dispositivo in presenza di apparecchiature che monitorizzano pazienti e Non usare T ONE con apparecchi di elettrochirurgia o di terapia ad onde corte o microonde e Vietato l uso a persone incapaci di intendere e di volere a persone che soffrono di disturbi alla sensibilit o a persone anche solo momentaneamente inabili se non assistite da personale qualificato es medico o terapista e Vietato l uso del dispositivo in presenza di segni di deterioramento del dispositivo stesso In caso di penetrazione di sostanze estranee nel dispositivo contattare immediatamente il rivenditore o il produttore In caso di caduta verificare che non siano presenti crepe del contenitore o lesioni di qualsiasi natura se presenti contattare il rivenditore o il produttore In caso di variazione delle prestazioni durante il trattamento interrompere immediatamente lo stesso e rivolgersi immediatamente
46. already practise good physical activity and wish to define their muscles in greater detail Method of use 1 identify the muscle to be treated To obtain good results we suggest to treat just a few muscles at a time and complete the process described below IACER SRL 05 08 Ed 12 10 10 Pag 44 2 position the electrodes as shown in the photo 3 increase the intensity until the impulse can be felt use a low intensity for the first session to help you to understand how the machine works 4 during the program and over the next few days the intensity should be increased gradually so that muscle contractions are not painful 5 during contraction generated by the unit contract the muscle voluntarily 6 acycle of 15 20 applications must be completed before the first results can be seen one application for each muscle every two days with a day of rest in between It is possible to work on pairs of muscles for example thighs and abdominal muscles treating thighs one day and abdominal the next day Working on too many muscles at the same time is not recommended Stimulation intensity 20 35mA E04 Definition SIS Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Total duration 25 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 H gu H ti Quadriceps Thighs photo
47. avi e aumentare l intensit al momento di premere assicurarsi di aver seguito dettagliatamente le ISTRUZIONI PRELIMINARI per iniziare la sessione di lavoro premere il tasto CO dei canali utilizzati per l elettrostimolazione ed aumentare l intensit di corrente in uscita T ONE si posizionera in automatico nella schermata di lavoro visualizzando il nome del programma scelto 7 Alzare l intensit di stimolazione con il tasto dei canali interessati fino al raggiungimento di tolleranza personale comfort di stimolazione IACER SRL MNPGO5 08 Ed 12 10 10 Pag 6 Programma Numero di fasi Tempo totale programma Indicatore stato di selezionato fase in corso countdown fase i incorso X carica della batteria Barra indicazione Descrizione 10 Hc 5 H programma Re Be coal In funzione fa Resistenza m recupero attivo Indicazione QU alll Canale in allarme canale in errore elettrodi funzione K OFF non collegati Valore in mA y intensit in 1zHa 1165 ma DS Indicazione canale uscita non attivo L immagine sopra ha scopo puramente esemplificativo e non descrive esattamente la videata del programma S10 Durante il funzionamento dell elettrostimolatore sul display appare una barra indicante inizio e fine della contrazione periodi di contrazione muscolare il pieno della barra e i periodi di recupero il tratteggio della barra vengono visualizzati graficamente con un cursore sotto
48. contrazione 7 sec contrazione E03 Tonificazione programmi di tonificazione consentono alla muscolatura trattata di migliorare il proprio trofismo L uso di questo programma indicato dopo aver terminato almeno un ciclo di 15 sedute del programma E02 Rassodamento Frequenza di trattamento 3 4 sedute settimanali L intensit di stimolazione deve essere media la contrazione deve essere sensibile ma tale da non provocare dolore 15 30mA primi risultati saranno percepibili gi dopo le prime 15 20 applicazioni e tenderanno a consolidarsi dopo due mesi di trattamenti regolari Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi E03 Tonificazione Durata totale programma 34 minuti O Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 ti Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 Fase 4 12 min Allenamento 12 min Allenamento 5 min Riscaldamento 13 sec recupero 13 sec recupero 5 min Defaticante 7 sec contrazione 7 sec contrazione E04 Definizione Questi programmi di stimolazione differenziano dai precedenti per la freq
49. ctement connecteur bien ins r T ONE revient au point de d part en cours d application On conseille de recharger les piles et de recommencer le traitement Si le probl me persiste remplacer les piles T ONE est allum mais rien n apparait sur l cran Ouvrir le compartiment batteries soulever la batterie la d connecter et l enlever Dans le compartiment batterie se trouve un petit trou au dessus duquel il est crit reset ins rer une petite pointe et appuyer doucement IACER SRL MNPGO5 08 Ed 12 10 10 Pag 63 I TECH MEDICAL DIVISION Elimination des d chets Pour sauvegarde de l environnement le dispositif les accessoires et surtout les batteries doivent tre limin s conform ment aux normes l gales dans des zones sp cialement quip es ou trait s avec les d chets sp ciaux 9 Electrostimulation et intensit de stimulation L lectrostimulation consiste transmettre au corps humain des micro impulsions lectriques Les champs d application de l lectrostimulation sont la th rapie de la douleur la r cup ration du trophisme musculaire apr s des traumatismes ou des interventions chirurgicales la pr paration des athl tes et les traitements esth tiques Pour chacune de ces applications des impulsions lectriques sp cifiques sont utilis es L intensit de la stimulation est repr sent e sur l cran de T ONE pour chaque canal avec une chelle croissante de 0 120 Dans
50. del contrasto display 15 Elettrodi adesivi Pag 24 16 Dichiarazione di conformita CE Pag 24 17 Caratteristiche tecniche Pag 25 18 Garanzia cartolina da compilare e spedire Pag 25 Norme di garanzia IACER SRL MNPG05 08 Ed 12 10 10 Pag 2 1 Presentazione IACER Srl intende ringraziarLa per l ottima scelta effettuata assicurarLe che l elettrostimolatore T ONE un dispositivo sviluppato con tecnologie moderne ed innovative concepito da una azienda italiana leader nella progettazione e nella produzione di elettrostimolatori professionali T ONE EVO I 11 Programmi Sport 9 Programmi Beauty 5 Programmi TENS T ONE EVO Il 11 Programmi Sport 9 Programmi Beauty 16 Programmi TENS 2 Contenuto del kit n 1 elettrostimolatore T ONE con batteria interna ricaricabile n 4 cavi di connessione a 2 terminazioni per la trasmissione degli impulsi elettrici n 2 conf da 4 elettrodi adesivi 41x41mm pregell ati 1 conf per T ONE EVO I n 2 conf da 4 elettrodi adesivi 40x80mm pregell ati 1 conf per T ONE EVO I n 1 conf da 8 elettrodi adesivi circolari 32 mm pregellati non presente su T ONE EVO 1 n 1 caricabatteria n 1 manuale utente T ONE n 1 manuale delle posizioni elettrodi Sono disponibili i seguenti accessori acquistabili a parte e Elettrodi adesivi pregellati misure 41x41mm 48X48mm 40x80 mm 50x90mm viso diam 32mm Fasce elasticizzate conduttive per elettrostimolazione per cosce e
51. delle fibre rapide L effetto l aumento della capacit delle fibre rapide di sopportare sforzi prolungati nel tempo In un atleta con caratteristiche di resistenza il programma di capillarizzazione risulta utilissimo sia per il recupero dopo sedute intense di lavoro aerobico sia prima di sedute di lavoro anaerobico sia nei periodi di impossibilit di allenamento maltempo infortuni Durata programma 30 min una fase Intensit di stimolazione suggerita media 20 30mA Posizione elettrodi fare riferimento alle posizioni da foto 01 a foto 20 IACER SRL 05 08 Ed 12 10 10 Pag 11 504 Agonista Antagonista L elettrostimolatore produce contrazioni alternate sui 4 canali durante la fase1 di riscaldamento i 4 canali lavorano contemporaneamente durante la fase 2 di lavoro vengono alternate le contrazioni muscolari prima sui canali 1 e 2 muscoli agonisti poi sui canali 3 e 4 muscoli antagonisti E un programma studiato per riportare a tono i muscoli del quadricipite e del suo antagonista bicipite femorale oppure bicipite brachiale e tricipite Il tipo di lavoro sullo sviluppo della forza Nella fase 2 di lavoro necessario selezionare tre volte l intensit quella per i quattro canali di recupero attivo quella per la contrazione dei canali 1 e 2 muscoli agonisti e quella per la contrazione dei canali 3 e 4 muscoli antagonisti Intensit di stimolazione durante la contrazione seguire le indicazioni riportat
52. e prestata attraverso il punto vendita di acquisto oppure rivolgendosi direttamente al costruttore 4 La garanzia copre esclusivamente i danni del prodotto che ne determinano un cattivo funzionamento Il prodotto garantito dovr riportare numero di serie uguale a quello indicato nel tagliando di garanzia pena l invalidit della garanzia 5 Per garanzia si intende esclusivamente la riparazione o sostituzione gratuita dei componenti riconosciuti difettosi nella fabbricazione o nel materiale mano d opera compresa 6 La garanzia non si applica in caso di danni provocati da incuria o uso non conformi alle istruzioni fornite danni provocati da interventi di persone non autorizzate danni dovuti a cause accidentali o a negligenza dell acquirente con particolare riferimento alle parti esterne 7 La garanzia non si applica inoltre a danni causati all apparecchio da alimentazioni non idonee Sono escluse dalla garanzia le parti soggette ad usura in seguito all utilizzo La garanzia non include i costi di trasporto che saranno a carico dell acquirente in relazione ai modi ed ai tempi del trasporto 10 Trascorsi i 2 anni la garanzia decade In tal caso gli interventi di assistenza verranno eseguiti addebitando le parti sostituite le spese di manodopera e le spese di trasporto secondo le tariffe in vigore 11 Per qualsiasi controversia competente in via esclusiva il foro di Venezia ale T ONE EVO II Tutti i diritti sono riservat
53. e all inizio del capitolo per i programmi Sport L aumento della intensit deve essere graduale ed eseguito trattamento dopo trattamento senza sovraffaticare i muscoli Se interviene la stanchezza sospendere gli allenamenti per qualche giorno ed eseguire il programma S02 recupero muscolare Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi S04 Agonista Antagonista Durata totale programma 33 minuti Bicipite cH1 cH2 foto 02 Tricipite foto 03 Estensori della mano cH1 CH2 foto 04 Flessori della mano cH3 cH4 foto 05 Ve Aug hn t d Quadricipiti cH1 CH2 foto 11 Bicipiti femorali cH3 cH4 foto 12 Fase 1 Fase 2 Fase 3 20 min di contrazioni alternate su coppia canali 6 sec recupero Tsec contrazione cH1 CH2 Tsec contrazione CH3 CH4 3 min Riscaldamento 10 min Defaticante 505 Forza resistente Il programma stato studiato per favorire un incremento della resistenza allo sforzo cio sostenere pi a lungo uno sforzo intenso nei distretti muscolari sottoposti a stimolazione Indicato per le discipline sportive che richiedono sforzi intensi e prolungati Intensit di stimolazione durante la contrazione seguire le indicazioni riportate all inizio del capitolo per i programmi Sport Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi S05 Forza resistente Durata to
54. e trait e C est pour cette raison que cette stimulation est certainement la plus difficile supporter mais elle est tr s efficace On la d conseille aux personnes particuli rement sensibles et de toute fa on il faut viter de placer les lectrodes dans des zones sensibles comme le visage et les organes g nitaux ou pr s des blessures Placement des lectrodes en forme de carr sur la zone douloureuse conform ment au sch ma 1 ou en suivant le guide du placement des lectrodes de la photo n 25 la photo n 33 A05 TENS BURST programme m dicaux Il s agit d une stimulation qui produit un effet TENS Training en utilisant les fr quences du TENS Conventionnel Il est utilis en particulier pour soigner les douleurs Son action est semblable celle du programme TENS Endorphinique La dur e du traitement est de 15 minutes et il comprend une phase Placement des lectrodes en forme de carr sur la zone douloureuse conform ment au sch ma 1 A06 Cervicalgie programme m dicaux seulement T ONE EVO Il Programme sp cifique pour le traitement des douleurs cervicales Intensit r gl e entre le seuil de sensibilit et le seuil douloureux l intensit est son maximum lorsque la musculature autour de la zone trait e commence se contracter Il faut faire 10 ou 12 traitements raison de 1 par jour pour obtenir les premiers r sultats et il faut continuer jusqu ce que les sympt mes aient disparu P
55. e trait e d am liorer son trophisme L emploi de ce programme est conseill apr s avoir termin au moins un cycle de 15 s ances du programme E02 Raffermissement Fr quence du traitement 3 4 s ances par semaine Le niveau de stimulation en intensit doit tre moyen on doit sentir la contraction mais elle ne doit pas provoquer de douleur 15 30mA On obtiendra les premiers r sultats d ja apr s 15 IACER SRL 05 08 Ed 12 10 10 Pag 70 ou 20 applications et ils auront tendance se consolider au bout de deux mois de traitements r guliers E03 Tonification Temps total du programme 34 minutes LI Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Ve AN we ae d Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 3 Phase 4 12 min entrainement 12 min entrainement 5 min chauffement 13 sec r cup ration 13 sec r cup ration 5 min d fatiguant 7 sec contraction 7 sec contraction E04 D finition Indiqu pour sculpter les muscles travail principalement sur les fibres musculaires rapides Adapt aux personnes ayant un bon niveau d activit physique qui
56. e un forte massaggio del muscolo trattato 20 30mA Posizione elettrodi fare riferimento alle posizioni da foto 01 a foto 20 09 Drenaggio Questi programmi con specifiche finalit drenanti aumentano la microcircolazione all interno e intorno alle fibre muscolari trattate creando inoltre delle contrazioni ritmiche facilitando cos il deflusso delle sostanze algogene e favorendo l attivit linfatica Pu essere applicato anche su persone non pi giovani per migliorare la circolazione sanguigna e linfatica programmi eseguono nelle fasi 2 e 3 delle contrazioni toniche sequenziali in grado di riprodurre l effetto tipico del drenaggio elettronico linfatico In questo caso per a differenza del programma lipolisi le contrazioni sono sequenziali prima CH1 poi CH2 CH3 4 Non esistono veri e propri limiti applicativi per questi programmi che possono essere eseguiti fino a raggiungimento del risultato desiderato L intensit di stimolazione deve essere sufficiente a garantire delle buone contrazioni muscolari durante il trattamento ma tali da non produrre indolenzimento 20 30mA Normalmente dopo 3 4 settimane con 4 5 sedute settimanali appaiono i primi risultati Descrizione programma gruppi muscolari interessati con riferimento foto posizionamento elettrodi E09 Drenaggio Durata totale programma 25 minuti Gruppi muscolari tutti i muscoli che si desidera stimolare in sequenza Collegare un canale per ogni muscolo con
57. eaviness and cramps may be experienced in the event of prolonged muscle stimulation Should this occur we recommend to suspende treatment with T ONE for a few days and then to continue with muscle recovery and capillarization programs Make sure that the plug and battery charger are intact Should one of these parts show any sign of damage suspend use of the battery charger immediately and contact the retailer or manufacturer It is forbidden to position the electrodes in such a way that the current crosses the heart area e g a black electrode on the chest and a red electrode on the shoulder blade however electrodes can be positioned along the muscular fascia of the heart area as used for pectoral strengthening Use of the device is prohibited with electrodes positioned on or close to injuries or cuts The electrodes must not be positioned on the carotid sinuses carotid or genitals The electrodes must not be positioned close to the eyes make sure that the current delivered does not cross the eyeball one electrode diametrically opposite to the other in relation to the eye keep a distance of at least 3 cm from the eyeball When using the electrodes follow the instructions given in this manual and on the package of the electrodes Use single patient electrodes supplied exclusively by the manufacturer and take care to avoid the exchange of electrodes between different users T ONE has been tested and guaranteed for use wit
58. ectronique Ces programmes peuvent tre r alis s l aide des lectrodes autocollantes L intensit de stimulation doit tre suffisante pour assurer de bonnes contractions musculaires pendant le traitement mais elle ne doit pas provoquer d endolorissement 20 25mA Le travail se fait principalement sur les fibres lentes 510 R activation 1 Temps total du programme 25 minutes Groupes musculaires programme concerne tous les muscles que l on veut stimuler Phase 1 Phase 2 Phase 3 Phase 4 10 minutes de contractions 10 minutes de contractions 3 min chauffement en s rie sur les 4 canaux en s rie sur les 4 canaux 2 min d fatiguant dur e impulsion 6 sec dur e impulsion 6 sec 611 R activation 2 contractions des fibres rapides s quentielles Ce programme cr e des contractions rythmiques avec une fr quence de stimulation typique des fibres rapides C est pr cis ment gr ce cette fr quence de stimulation plus lev e qu il se pr te bien l augmentation de la force s quentielle sur plusieurs muscles Ces programmes ex cutent dans les phases 2 et 3 des contractions par phases s quentielles sur les 4 canaux Ils peuvent tre r alis s l aide des lectrodes autocollantes Le niveau de stimulation en intensit doit tre suffisant pour assurer de bonnes contractions musculaires pendant le traitement mais il ne doit pas provoquer d endolorissement 20 40mA Contrairement au programme p
59. ei muscoli circostanti l area trattata Per questo motivo tale stimolazione certamente quella meno tollerata ma di grande efficacia E un tipo di stimolazione che si sconsiglia alle persone particolarmente sensibili ed in ogni caso da evitare di posizionare gli elettrodi in zone sensibili come viso genitali prossimit di ferite Posizione elettrodi formando un quadrato sopra la zona dolente come figura 1 o fare riferimento alle posizioni da foto 25 a foto 33 A05 TENS impulsi Burst Programma medicale Stimolazione che produce effetto tens training utilizzando frequenze della tens convenzionale Molto usata in terapia del dolore L azione simile a quella del programma TENS endorfinico con durata del trattamento 15 minuti con una fase Posizione elettrodi formando un quadrato sopra la zona dolente come figura 1 A06 Cervicalgia Cefalea Programma medicale Solo per modello T ONE EVO II Programma specifico per il trattamento del dolore in zona cervicale IACER SRL MNPGO5 08 Ed 12 10 10 Pag 20 Intensit regolata fra la soglia di percezione la soglia del dolore il limite massimo di intensit rappresentato dal momento in cui la muscolatura circostante l area trattata inizia a contrarsi oltre questo limite la stimolazione non aumenta la sua efficacia ma solo il senso di fastidio quindi bene fermarsi prima di tale soglia Il numero di trattamenti per ottenere i primi benefici trai 10 e i 12 con frequenza g
60. ement des douleurs quotidiennes en g n ral Il faut en moyenne 10 12 traitements appliquer raison de 1 par jour pour obtenir des r sultats on peut doubler la dose sans qu il y ait de contre indication Ce programme dure 30 minutes et il ne comprend qu une seule phase En cas de douleur particuli rement persistante r p ter le programme la fin de la s ance Placement des lectrodes en forme de carr sur la zone douloureuse conform ment au sch ma 1 A02 TENS endorphinique programme m dicaux Ce type de stimulation produit deux effets selon le positionnement des lectrodes en pla ant les lectrodes dans le dos comme le montre la photo n 8 du guide des positions il favorise la production endog ne de substances semblables la morphine qui ont la propri t d lever le seuil de sensibilit de la douleur en pla ant les lectrodes en forme de carr sur la zone douloureuse conform ment au sch ma 1 il produit un effet de vascularisation La vascularisation augmente le d bit art riel entra nant ainsi l limination des substances algiques et le r tablissement des conditions physiologiques normales Dur e du traitement 20 minutes en une seule phase raison d une fois par jour Ne pas placer les lectrodes pr s des zones sujettes des inflammations R gler l intensit de fa on produire une bonne sollicitation de la zone stimul e 10 20mA vous devez prouver la m me sensation que lors d
61. ers photo 19 H H D Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 3 Phase 4 10 min entrainement 5 min entrainement 5 min chauffement 13 sec r cup ration 14 sec r cup ration 5 min d fatiguant 7 sec contraction 6 sec contraction IACER SRL MNPGO5 08 Ed 12 10 10 Pag 71 E05 Adipostress Grace a la combinaison de capillarisation et de tonification ce program permet de cibler la graisse dans des zones o elle s accumule Les lectrodes doivent tre positionn es pour former un carr autour de la zone traiter Il est possible de faire des s ances quotidiennes en utilisant un niveau d intensit moyen Dur e du programme 30 minutes une phase Position des lectrodes photos 1 20 et photos 22 et 23 du manuel E06 Microlifting Ce programme d une dur e de 15 minutes en une seule phase est utilis pour tonifier les muscles du visage grace a une impulsion particuli re qui am liore tant leur aspect esth tique que dynamique Placement des lectrodes cf guide du placement des lectrodes photo 24 maintenir une distance minimale de 3 cm entre l lectrode et le globe oculaire N IMPORTANT attention au r glage de l intensit car les muscles faciaux sont particuli rement sensibles on conseille donc de r gler l intensit graduellement en partant d un niveau de st
62. es before placing the electronic stimulator in the bag If not the cables will bend excessively close to the connectors This may damage the cables IACER SRL 05 08 Ed 12 10 10 Pag 36 9 Resolution of problems and questions Any type of work on T ONE must be carried out exclusively by the manufacturer or by an authorised dealer In any event any presumed malfunction of T ONE must be verified before sending the device to the manufacturer Here below are some typical situations T ONE cannot be turned on Recharge the batteries and try to switch it on again if it still does not switch on check that the power supply socket is working Check that the ON OFF button has been pressed correctly held down for at least one second T ONE does not transmit electric impulses Check that the cable jacks have been inserted in the electrodes and that the plastic protection has been removed from the electrode Check that the cables have been connected correctly connector well inserted in the device T ONE switches off during operation Recharge the batteries for 8 hours and start the treatment again If the problem persists contact the manufacturer T ONE is switched on but nothing appears on the display Open the battery compartment lift up the battery disconnect the connection and remove it Inside battery compartment you ll find a little hole with RESET writing above insert a little tip and gently press
63. esn t receive electromagnetic interferences from other equipments However it s opportune to use the instrument keeping it at least at 3 meters from televisions monitors cellular telephones or any other electronic equipment The device must not be used in the presence of patient monitoring equipment Do not use T ONE with electrosurgical or shortwave or microwave therapy equipment Use of the device is prohibited to persons known to be of unsound mind to persons suffering from sensibility disorders and to permanently or temporarily disabled persons unless assisted by qualified personnel e g a doctor or therapist Use of the device is prohibited in the presence of signs of deterioration of the device itself Should any foreign materials penetrate the device contact the retailer or manufacturer immediately If dropped down check that the housing is not cracked or damaged in any way if so contact the retailer or manufacturer Should you notice any changes in the device s performance during treatment interrupt the treatment immediately and consult the retailer or manufacturer patients being treated in a centre must also be informed of the event Use of the device is prohibited in combination with other medical devices Use of the device is prohibited close to flammable substances or in environments with high concentrations of oxygen Consult a doctor before using T ONE with metallic osteosynthesis devices Muscle h
64. filo che porta l informazione del dolore La durata del trattamento non deve essere inferiore 30 40 minuti La tens convenzionale una corrente che pu essere utilizzata nel trattamento dei dolori quotidiani in genere Il IACER SRL MNPGO5 08 Ed 12 10 10 Pag 19 ll MEDICAL DIVISION numero di trattamenti richiesti in media per riscontrare dei benefici 10 12 con frequenza giornaliera nessuna controindicazione nel raddoppiare la dose Il programma ha una durata di 30 minuti in una sola fase In caso di dolore particolarmente insistente al termine di una seduta ripetere il programma Posizione elettrodi formare un quadrato sopra la zona dolente come figura 1 A02 TENS endorfinico Programma medicale Questo tipo di stimolazione produce due effetti in relazione al posizionamento degli elettrodi posizionando gli elettrodi in zona dorsale con riferimento foto 08 del manuale delle posizioni favorisce la produzione endogena di sostanze morfinosimili che hanno la propriet di innalzare la soglia di percezione del dolore con posizionamento elettrodi formando un quadrato sopra la zona dolente come figura 1 produce un effetto vascolarizzante L azione di vascolarizzazione produce un aumento della portata arteriosa con un conseguente effetto positivo sulla rimozione delle sostanze algogene ed un ripristino delle condizioni fisiologiche normali Durata del trattamento 20 minuti in una sola fase frequenza giornaliera Non posizi
65. form a square over the painful area IACER SRL MNPGO5 08 Ed 12 10 10 Pag 47 as shown in illustration 1 produces a vascularizing effect Vascularization increases arterial flow and consequently aids the removal of algogenic substances and helps to restore normal physiological conditions Treatment duration 20 minutes in a single phase daily frequency Do not position the electrodes close to inflamed areas Intensity adjusted for good solicitation of the part stimulated the sensation must be similar to that of a massage A03 TENS sequential Medical program The action is very similar to that of the 01 program In this program the impulse frequency and amplitude are varied during stimulation in order to counter the effect of the user becoming accustomed to the stimulation continuous increases of intensity will not be required Select the intensity at the start of the program and maintain the same level until the end of the program The user s perception of the current may almost become nonexistent during the program if this occurs do not increase the intensity and wait until the program has finished The TENS program is working correctly Program duration 20 minutes per phase Intensity slightly above the threshold of perception Position of the electrodes form a square over the painful area as shown in illustration 1 or refer to the positions illustrated from photo 25 to photo 33 A04 TENS maximum value Medical program
66. fort c est dire soutenir pendant plus longtemps un effort intense dans les groupes musculaires soumis une stimulation Il est indiqu pour les disciplines sportives qui demandent des efforts intenses et prolong s Intensit de stimulation durant la contraction suivre les indications mentionn es au d but du chapitre concernant les programmes Sport 505 R sistance tata CA T Phase 1 Temps total du programme 30 minutes Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 2 Phase 3 Phase 4 5 min chauffement 10 min entrainement 20 sec r cup ration 10 sec contraction 10 min entrainement 20 sec r cup ration 10 sec contraction 5 min d fatiguant IACER SRL MNPGO5 08 Ed 12 10 10 Pag 66 506 Force Ce programme est utilis dans le domaine sportif pour d velopper la force de base qui est par d finition la tension maximale qu un muscle peut exercer contre une r sistance constante Pendant la phase de travail les contractions alternent avec des p riodes de r cup ration active permettant ainsi d entrainer le muscle sans le soumettre
67. gli occhi e non investire il bulbo oculare con la corrente erogata un elettrodo diametralmente opposto all altro rispetto all occhio mantenere una distanza minima di 3 cm dal bulbo oculare Per l uso degli elettrodi seguire le indicazioni riportate nel presente manuale e sulla confezione degli elettrodi stessi Utilizzare elettrodi monoutente forniti esclusivamente dal produttore o dal rivenditore ed evitare accuratamente lo scambio di elettrodi fra utilizzatori diversi Usare solo elettrodi forniti dal costruttore T ONE testato e garantito per l uso con gli elettrodi in dotazione Elettrodi di sezione inadeguata possono provocare reazioni della pelle o scottature Solo per le applicazioni sul viso utilizzare elettrodi rotondi Non utilizzare gli elettrodi se sono danneggiati anche se aderiscono bene alla cute Vietato l uso quando l elettrodo non aderisce pi alla cute Un reiterato utilizzo degli stessi elettrodi pu compromettere la sicurezza della stimolazione infatti pu causare un arrossamento cutaneo che persiste parecchie ore dopo la fine della stimolazione Attenzione nel caso degli elettrodi rotondi durante il trattamento possibile superare una densit di corrente di 2mA cm per ogni elettrodo In questi casi porre particolare attenzione ad eventuali arrossamenti cutanei Vita utile del prodotto 5 anni IACER SRL MNPGO5 08 Ed 12 10 10 Pag 4 I TECH 5 Legenda simboli posti su T ONE e nel manuale C
68. h 2010 Organisme notifi Cermet Via di Cadriano 23 40057 Cadriano di Granarolo BO ITALY Le dispositif T ONE EVO EVO Il est un dispositif de classe conform ment l annexe IX r gle 9 de la Directive 93 42 CEE et successive modifications Martellago le 29 03 2010 Le repr sentant l gal E aprara 16 Caract ristiques techniques Classe de risque conform ment la directive 93 42 CEE et successive modifications Classe d isolation type BF conform ment la r glementation CEI EN 60601 1 Classification 0 selon le niveau de protection contre la p n tration des liquides et des poussi res Boitier ABS Alimentation Ni Mh batteries 4 8V 1600mAh Chargeur model XKD C0300NHS6 0 5W input 100 240 VAC 50 60Hz output VDC 300mA Consommation moyenne 1 W Limitations Ne pas utiliser l appareil dans des pi ces o il y a une grande concentration d oxyg ne et ou de liquides inflammables et ou de gaz inflammables ne pas l utiliser avec des appareils d lectrochirurgie ou de traitement ondes courtes ou micro ondes Fonctionnement peut fonctionner sans arr t Protections internes contre l inversion de p les des piles et les surcharges Canaux de sortie 4 canaux compl tement ind pendants et isol s par galvanisation Courant d alimentation 218mA de puissance maximale pic pic 31mA max efficaces pour chaque canal avec une charge de 200 ohm 1Kohm Type d impulsio
69. h the electrodes supplied Insufficiently sized electrode sections can cause skin reactions or burns Only use the round electrodes supplied by the manufacturer for facial applications Do not use electrodes when damaged even if they stick to the skin well Electrodes must not be used when they no longer stick to the skin Repeated use of the same electrodes can compromise the safety of the stimulation in fact it can cause skin redness that can last for many hours after stimulation Warning During treatment with round and 35 x 45 mm electrodes current density may be in excess of 2 mA cm for each electrode In these cases take special care regarding any skin redness Product expected lifetime 5 years IACER SRL MNPGO5 08 Ed 12 10 10 Pag 32 I TECH 5 Legend manual C Si wee lt gt g 9 9 of symbols marked and found in the Produced in compliance with the 93 42 EEC directive concerning medical devices Internally powered device with type BF applied parts Class Il equipment Electrostatic discharge sensibility ESD Product subject to WEEE regulations concerning separate waste collection Read the instructions for use carefully before using the device ON OFF button Select program and muscles to stimulate Select Sport Beauty Tens programs male and female Start Stop program confirm selection Increase intensity Decrease intensity 6 How to use
70. hey are particularly suitable for electrostimulation treatments They are very flexible making it easy to treat all areas Remove the protective plastic from the electrode before use position it on the skin as shown in the manual and replace the plastic after use Electrode duration is determined by the skin s pH value we recommend no more than 20 applications using the same electrode Repeated use of the same electrodes can compromise stimulation safety do not use electrodes when they no longer stick to the skin in fact it can cause skin redness that can last for many hours after stimulation Consult a doctor if this occurs 16 Declaration of Conformity IACER S r l headquartered in Italy via S Pertini 24 A 30030 Martellago VE declares on its own responsibility devices T ONE EVO I and T ONE EVO II is manufactured in conformity with 93 42 EEC Directive MDD as amended by 2007 47 CE date 25 September 2007 T ONE EVO I and T ONE EVO II are Class lla devices with reference to 93 42 EEC Directive MDD annex IX rule 9 and following modifications Dir 2007 47 CE Martellago 29 03 2010 Legal representative Mario Caprara 17 Technical specifications Risk class Ila in accordance with the 93 42 EEC directive and following modifications Insulation class Internally powered device with type BF applied parts in accordance with the EN 60601 1 standard Classification IP30 based on the penetration of liquids and powder eq
71. hme acc l r la contraction est br ve tout comme est br ve la r cup ration Normalement il faut faire un cycle de trois semaines de force de base une intensit croissante Ensuite il faut faire un cycle de trois semaines de force rapide raison de trois fois par semaine avec une intensit de stimulation lev e durant la contraction 30 50 507 Force vitesse Temps total du programme 26 minutes O Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Ve AN NC ae Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 3 Phase 4 10 min entrainement 8 min entrainement 3 min chauffement 14 sec r cup ration 10 sec r cup ration 5 min d fatiguant 6 sec contraction 5 sec contraction IACER SRL MNPGO5 08 Ed 12 10 10 Pag 67 Q MEDICAL DIVISION 508 Force explosive Les programmes de force explosive favorisent l augmentation de la capacit explosive et de la vitesse de la masse musculaire avec des contractions de renforcement extr mement br ves et une r cup ration active tr s longue pour permettre au muscle de dig rer l effort Normalement il faut faire un cycle de trois sem
72. hree weeks at high intensity 30 50mA Intensity must be increased gradually treatment by treatment without overstraining the muscles Suspend training for a few days in the event of fatigue and proceed with the S 02 program 06 Basic strenght tata CA Total duration 30 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Ve AN NC ae fl d Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 5 min warm up 13 sec recovery 14 sec recovery 5 min recovery 7 sec contraction 6 sec contraction IACER SRL MNPGO5 08 Ed 12 10 10 Pag 40 507 Speed Fast strength This program is designed to increase speed in fast athletes and develop it in athletes lacking the quality The exercise assumes a fast pace and the contraction is short as is the recovery It is usually best to complete a three week basic strength cycle of increasing intensity before using this program Then continue with three weeks of fast strength three times a week at high intensity 30 50mA during the contraction S07 Fast strenght Total duration 26 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors
73. i T ONE EVO Il e il logo mision SONO di propriet di IACER Srl e sono registrati IACER SRL MNPGO5 08 Ed 12 10 10 Pag 26 I TECH IACER SRL MNPGO5 08 Ed 12 10 10 Pag 27 I TECH IACER SRL 05 08 Ed 12 10 10 Pag 28 WARNING T ONE IS A MEDICAL DEVICE Consult your doctor before using T ONE if you suffer from health problems using T ONE Read the contraindications and warnings carefully Read the user manual and the electrode position manual before before using the medical programs IACER S r l via Pertini 24 A 30030 Martellago Venezia Italy Tel 39 041 5401356 Fax 39 041 540 2684 iacer iacer it www itechmedicaldivision com IACER SRL MNPGO5 08 Ed 12 10 10 Pag 29 Q MEDICAL DIVISION USER MANUAL TABLE OF CONTENTS 1 Presentation Page 31 2 T ONE kit contents Page 31 3 Purpose Page 31 Contraindications and side effects 4 Warnings Page 32 5 Legend of symbols marked on T ONE and found in the manual Page 33 6 How to use T ONE Page 33 Description of controls Preliminary instructions Operating instructions 7T Battery charging Page 36 8 T ONE maintenance and storage Page 36 9 Resolution of problems and questions Page 37 10 Electrostimulation and T ONE stimulation intensities Page 37 11 Sport programs Page 38 12 Beauty programs Page 43 13 T E N S programs Page 46 14 SETUP Page 51 15 Self adhesive electrodes Page 52 16 Declaration of Conformity Page 52 17 Technical s
74. i res s ances d lectrostimulation faible intensit de mani re permettre l organisme de s adapter des sensations nouvelles De cette fa on l augmentation de l intensit sera progressive et en rien traumatisante IACER SRL MNPGO5 08 Ed 12 10 10 Pag 64 10 Programmes Sport N IMPORTANT Intensit de stimulation les programmes sport R sistance Force Muscles Agonistes Antagonistes comprennent plusieurs phases chauffement travail et r cup ration Pendant la phase d chauffement phase 1 l intensit de stimulation est r gl e de fa on produire une assez bonne sollicitation du muscle trait afin de l chauffer sans le fatiguer 18 30mA Pendant les phases de travail les phases centrales des programmes on fait alterner les impulsions de contraction et les impulsions de r cup ration active Il faut s lectionner s par ment les deux intensit s pour la contraction visualis e sur l cran par la barre pleine 20 30mA pour les personnes peu entra n es 30 50mA pour les personnes entra n es et plus de 50mA pour les personnes tr s entrain es On conseille de r gler l intensit de r cup ration entre une contraction et l autre environ 1522096 de moins que l intensit de contraction Pendant la phase de r cup ration derni re phase l intensit doit tre r gl e de facon produire un bon massage de la partie stimul e sans g n rer de la douleur 18 30 S01 Echauffemen
75. ia del dispositivo utilizzare esclusivamente un panno asciutto E consigliabile effettuare presso la ditta produttrice un controllo funzionale ogni 24 mesi Il fabbricante non considera il dispositivo T ONE riparabile da parte di personale esterno all azienda stessa Ogni intervento in tal senso da parte di personale non autorizzato dalla ditta costruttrice verr considerato manomissione del dispositivo sollevando il costruttore dalla garanzia e dai pericoli a cui pu essere sottoposto l operatore o l utilizzatore N B prima di riporre l elettrostimolatore scollegare i cavi Se ci non viene fatto i cavi assumono pieghe eccessive sui connettori Ne pu derivare un danneggiamento dei cavi 9 Risoluzione di problemi e quesiti Ogni tipo di intervento su T ONE dovr essere effettuato solo dal produttore o dal rivenditore autorizzato In ogni caso prima di spedire T ONE al costruttore sar necessario assicurarsi del reale malfunzionamento di T ONE Di seguito alcune situazioni tipiche T ONE non si accende Verificare che sia presente la batteria nell apposito vano Provare a ricaricare la batteria e quindi ritentare l accensione Verificare di aver premuto correttamente il tasto di accensione almeno un secondo di pressione T ONE non trasmette impulsi elettrici Assicurarsi di aver collegato gli spinotti dei cavi agli elettrodi e di aver staccato l elettrodo dalla plastica di conservazione Assicurarsi che i
76. icazioni consecutive giornaliere Intensit regolata appena la soglia di percezione Individuata la parte da trattare posizionare gli elettrodi a quadrato come fig 1 Durata programma 30 minuti in una fase 11 Vascolarizzazione Programma non medicale Solo per modello T ONE EVO II Produce un effetto vascolarizzante nella zona trattata L azione vascolarizzante produce un aumento della portata arteriosa con un conseguente effetto positivo sulla rimozione delle sostanze algogene ed un ripristino delle condizioni fisiologiche normali Non posizionare gli elettrodi in prossimit di aree soggette a stati infiammatori La frequenza di applicazione suggerita giornaliera il numero di applicazioni non definito il programma pu essere utilizzato fino alla riduzione del dolore stesso L intensit di stimolazione suggerita deve essere compresa tra la soglia di percezione e la soglia di leggero fastidio Durata programma 20 minuti in una fase Posizione elettrodi fare riferimento alle posizioni da foto 25 a foto 33 12 Decontratturante Programma non medicale Solo per modello T ONE EVO II Programma indicato per accelerare il processo di recupero funzionale del muscolo svolge una azione immediata Intensit regolata appena sopra la soglia di percezione Due trattamenti quotidiani per tre o quattro giorni Descrizione programma con riferimento posizione elettrodi A12 Decontratturante Durata totale programma 3
77. idiennes faible intensit si on augmente l intensit il faut permettre la musculature de r cup rer en laissant une journ e de repos entre les applications A15 Pr vention atrophie Temps total du programme 30 minutes O Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 D mm d Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Oblique de l abdomen photo 22 Hanches photo 23 Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 5 min chauffement Phase 2 Dur e 10 minutes 9 sec r cup ration 6 sec contraction Phase 3 Dur e 10 minutes 9 sec r cup ration 6 sec contraction phase 4 5 min d fatiguant IACER SRL MNPGO5 08 Ed 12 10 10 Pag 77 E MEDICAL DIVISION A16 Amyotrophie programme m dicaux seulement T ONE EVO II Ce programme travaille de facon s lective sur les fibres lentes Il est id al pour la r cup ration de la masse musculaire apr s une longue p riode d inactivit ou un accident Il doit tre ex cut au cas o la masse musculaire aurait d j fondu Il doit appliqu avec prudence faible intensit suffisante pour produire de l g res contractions musculaires durant les 2 ou 3 premi res sema
78. imulation tr s bas par exemple 3 5mA pour ensuite l augmenter avec une extr me prudence jusqu atteindre un bon niveau de stimulation repr sent par une bonne activation des muscles IMPORTANT il n est pas n cessaire de r gler les intensit s jusqu au seuil douloureux L quation plus de douleur meilleur r sultat est compl tement trompeuse et produit l effet contraire C est avec patience et pers v rance que l on atteint des objectifs importants E07 Massage relaxant 1 Ce programme peut tre utilis quotidiennement pour soulager les muscles apr s l effort Dans le domaine du sport il est connu sous le nom de r cup ration Apr s une dure journ e de travail en particulier pour les personnes qui restent debout longtemps ce programme active la circulation et augmente l oxyg nation des muscles pour une relaxation efficace on peut effectuer une premi re application sur les mollets puis une autre sur les cuisses Dur e du programme 15 minutes Intensit de stimulation moyenne basse 15 20 mA de fa on obtenir des secousses musculaires visibles Augmenter progressivement l intensit pour obtenir un massage vigoureux Rester en dessous du seuil de contraction musculaire Position des lectrodes voir photos 1 20 du manuel E08 Massage relaxant 2 Ce programme augmente la circulation sanguine am liore l oxyg nation du muscle et ainsi aide liminer les toxines et l acide lactique produits pendant
79. induite qui accroit l activit m tabolique et le d bit sanguin et donc permet d am liorer l oxyg nation des tissus On amplifie donc l effet positif du TENS en le combinant avec la stimulation musculaire IACER SRL MNPGO5 08 Ed 12 10 10 Pag 73 Placement des lectrodes et intensit Les lectrodes sont plac es en carr tout autour de la zone douloureuse en utilisant le canal 1 et le canal 2 conform ment au sch ma 1 L intensit doit tre r gl e entre le seuil de sensibilit et le seuil douloureux on atteint la limite maximale d intensit lorsque la musculature autour de la zone trait e commence se contracter au del de cette limite la stimulation ne devient pas plus efficace mais procure au contraire une g ne il convient donc de s arr ter avant ce seuil 2 CLIP CLIP Sch ma 1 ROUGE Canal 1 Canal 2 A IMPORTANT Appliquer les lectrodes en forme de carr sur la zone douloureuse en gardant une distance minimale de 4 cm entre chaque lectrode gue A01 TENS classique programme m dicaux Ce programme appel galement TENS Conventionnel est utilis pour lutter contre la douleur son action a pour but de bloquer la douleur dans l organisme au niveau de l pine dorsale conform ment la th orie de la porte gate control de Melzack et Wall La dur e du traitement ne doit pas tre inf rieure 30 40 minutes Le TENS Conventionnel est un courant qui peut tre utilis dans le trait
80. ines Augmenter progressivement l intensit au cours des 3 ou 4 semaines suivantes Appliquer tous les deux jours A16 Amyotrophie Temps total du programme 30 minutes Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Oblique de l abdomen photo 22 Hanches photo 23 Ue AN NC ae Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 3 Dur e 25 minutes 6 sec di r cup ration 6 sec contractions 3 min chauffement 2 min d fatiguant 13 Mise en marche Choix de la langue et du contraste sur l cran Appuyer sur la touche ON OFF et le maintenir enfonc jusqu ce que la liste de choix de la langue apparaisse sur l cran Rel cher cette touche et utiliser les curseurs pour choisir la langue et le contraste S lectionner la langue d sir e en utilisant les curseurs GD Gp Ajuster le niveau de contraste de l cran en utilisant les curseurs g 9 Appuyer sur la touche amp pour valider vos choix 14 Electrodes adh sives Pour placer les lectrodes consulter le manuel des positions des lectrodes Les lectrodes fournies par le producteur sont de premi re qualit elles sont pr r gl
81. ingue Rilasciare i tasti ora con i cursori del mouse potete selezionare la lingua oppure regolare il contrasto del display Selezionare la lingua prescelta aiutandosi con i tasti GD GOD Regolare il contrasto del display con i tasti 4 9 Per confermare le selezioni premere il tasto 15 Elettrodi adesivi Per la posizione degli elettrodi vedere le foto delle posizioni elettrodi Gli elettrodi in dotazione sono pregellati e pronti all uso sono particolarmente indicati per trattamenti di elettrostimolazione La grande flessibilit ne permette una facile applicazione nel trattamento delle diverse aree Per l utilizzo togliere l elettrodo dall apposita plastica protettiva posizionarlo sulla cute come indicato nel manuale e dopo l uso riattaccarlo alla plastica protettiva La durata di un elettrodo determinata dal pH della pelle si consiglia comunque di non superare le 20 applicazioni con lo stesso elettrodo Un reiterato utilizzo degli stessi elettrodi pu compromettere la sicurezza della stimolazione per questo motivo ne vietato l uso quando l elettrodo non aderisce pi alla cute ne pu infatti derivare un arrossamento cutaneo che persiste parecchie ore dopo la fine della stimolazione In tal caso consultare un medico 16 Dichiarazione di conformit CE La ditta IACER Srl con sede in via S Pertini 24 A 30030 Martellago VE ITALIA dichiara che i dispositivi della famiglia T ONE modelli T ONE EVO e T ONE EVO II s
82. iornaliera proseguire nei trattamenti fino alla scomparsa dei sintomi Descrizione programma con riferimento foto manuale posizionamento elettrodi Posizione elettrodi cervicale foto 25 Fase 1 Fase 2 Tens ad impulso stretto 30 min Decontratturante 3 min A07 Lombalgia Programma medicale Solo per modello T ONE EVO II Programma specifico per il trattamento del dolore in zona dorsale o lombare o entrambe Intensit regolata fra la soglia di percezione e la soglia del dolore il limite massimo di intensit rappresentato dal momento in cui la muscolatura circostante l area trattata inizia a contrarsi oltre questo limite la stimolazione non aumenta la sua efficacia ma solo il senso di fastidio quindi bene fermarsi prima di tale soglia Il numero di trattamenti per ottenere i primi benefici trai 12ei 15 con frequenza giornaliera proseguire nei trattamenti fino alla scomparsa dei sintomi Descrizione programma con riferimento foto posizionamento elettrodi 07 Lombalgia Durata totale programma 35 minuti Posizione elettrodi dorsale paravertebrali foto 10 lombare foto 27 Fase 1 Fase 2 Tens ad impulso stretto 30 min Tens impulsi Burst 5 min 08 Sciatalgia Programma medicale Solo per modello T ONE EVO Programma specifico per il trattamento del dolore causato da infiammazione del nervo sciatico foto 28 Intensit regolata fra la soglia di percezione e la soglia del do
83. ipolysis drainage impulse the pump effect is produced by sequential tonic contractions The intensity must be enough to produce these contractions the greater the contraction is the greater the pump effect will be But beware there is no benefit to be gained from enduring intensity high enough to cause pain The first electrostimulation sessions should be carried out at a low intensity to allow the organism to get used to new sensations That way intensity can be increased gradually and will not be traumatic 3 Warming up impulse stimulation intensity must be increased gradually to improve the metabolism of the muscle concerned progressively A bit like with a car the engine needs warming up before it is taken to full speed 4 Toning training atrophy contraction impulse the muscle treated must visibly contract during a training impulse The fact that the muscle tends to stiffen and increase in volume will be visible Intensity should be increased gradually in the first contraction to enable you to identify the right level of stimulation comfort Intensity can be increased up to the personal tolerance threshold during the second training contraction this operation is then repeated during each contraction until the workload reaches the level of intensity recommended in the description of the single programs We recommend that you record the level of intensity reached in order to improve the level of stimulation and consequently your perf
84. la barra stessa In questo modo l utente conosce esattamente il momento in cui inizia la contrazione 8 Al termine della prima fase T ONE azzera l intensit precedentemente selezionata avvisando l utente con un segnale intermittente per procedere con il programma premere nuovamente il tasto f dei canali collegati fino al raggiungimento del livello di stimolazione desiderato La fine del programma viene segnalata con un triplo segnale acustico 9 Al termine del programma spegnere T ONE togliere i cavi Attaccare gli elettrodi sulle pellicole trasparenti e riporli nelle confezioni di origine Opzione per aumentare l intensit contemporaneamente su tutti i canali Selezionare il programma desiderato Avvio programma Aumentare almeno fino ad intensit 1 per ogni singolo canale A CH1 A CH2 A CH3 A CH4 Blu Giallo 0550 Bianco Per aumentare contemporaneamente l intensit di tutti i canali utilizzare i tasti Aumenta ug Diminuisce IACER SRL MNPGO5 08 Ed 12 10 10 Pag 7 410 MEDICAL DIVISION Comando salto fase durante il normale funzionamento del programma premendo il tasto 9 si salta alla fase successiva Comando pausa arresto programma durante il funzionamento del programma premendo una volta il tasto o si sospende momentaneamente il normale ciclo di funzionamento per ripartire premere nuovamente il tasto O Per interrompere il programma necessario spegnere l apparecchio
85. lacement des lectrodes sur la nuque photo n 25 Phase 1 Phase 2 Tens impulsion br ve 30 minutes D contractant 3 minutes A07 Lombalgie programme m dicaux seulement T ONE EVO II Programme sp cifiques pour le traitement des douleurs dans la r gion lombaire ou par l inlammation du nerf sciatique Intensit r gl e entre le seuil de sensibilit et le seuil douloureux l intensit est son maximum lorsque la musculature autour de la zone trait e commence se contracter Il faut faire de 12 15 traitements raison de 1 par jour pour obtenir les premiers r sultats et il faut continuer jusqu ce que les sympt mes aient disparu A07 Lombalgie Sciatalgie Temps total du programme 35 minutes Placement des lectrodes lombaire photo 27 sciatalgie photo 28 IACER SRL MNPGO5 08 Ed 12 10 10 Pag 75 Phase 1 Phase 2 Tens impulsion br ve 30 minutes Tens impulsion Burst 5 minutes A08 Lombo sciatalgie programme m dicaux seulement T ONE EVO II Programme sp cifique pour le traitement des douleurs sciatiques L intensit doit tre ajust e un niveau sup rieur au seuil de perception et inf rieur au seuil de douleur l intensit maximale est atteinte au moment o les muscles proches de la zone traiter commence se contracter il faut rester en dessous de cette limite car au del de ce seuil la stimulation n est plus efficace Ce traitement porte ses fruits apr
86. lcune applicazioni sportive prende il nome di defaticante Dopo una intensa giornata di lavoro in particolare per chi trascorre molte ore in piedi questo programma riattiva la microcircolazione sanguigna eliminando l effetto pesantezza alle gambe in questa applicazione gli elettrodi vanno posti prima sui polpacci eseguendo una volta il programma poi sulle cosce eseguendo una seconda volta il programma Intensit iniziale suggerita media 15 20mA tale da produrre un buon movimento della parte trattata aumentare progressivamente l intensit fino a raggiungere un forte massaggio dell area trattata 20 30mA Durata programma 15 minuti una fase Posizione elettrodi fare riferimento alle posizioni da foto 01 a foto 20 E08 Defaticante generale Con questo programma si migliora l afflusso sanguigno e l ossigenazione del muscolo accelerando il processo di smaltimento dell acido lattico prodotto dopo sedute anaerobiche IACER SRL MNPG05 08 Ed 12 10 10 Pag 17 favorendo la riduzione di indolenzimenti e possibilit di contratture Grazie all utilizzo di questo programma il muscolo trattato sar pronto pi velocemente per una nuova sessione di allenamento o competizione Il programma ha durata di 15 minuti in 3 fasi con passaggio automatico alla fase successiva Intensit iniziale suggerita medio bassa 15 25mA tale da produrre un buon movimento della parte trattata aumentare progressivamente l intensit fino a raggiunger
87. les mollets Gel pour lectroth rapie 2 Emploi Contre indications et effets collat raux L lectrostimulateur T ONE est un appareil m dical dont l emploi est particuli rement indiqu pour les kin sith rapeutes pour les pr parateurs sportifs dans un centre ou un cabinet de consultation priv pour les op rateurs professionnels dans un institut de beaut Cet appareil peut tre galement utilis domicile par des adultes ayant soigneusement lu le mode d emploi Le fabricant recommande que des programmes m dicaux tels que les programmes de Tens et de r ducation soient r alis s sous surveillance m dicale Contre indications L utilisation est interdite aux personnes portant un pace maker aux cardiaques aux pileptiques aux femmes enceintes aux personnes souffrant de phl bites d tat f brile de thrombophl bites aux personnes anxieuses et en pr sence de maladies graves En pr sence de traumatismes de tensions musculaires ou de tout autre probl me de sant n utiliser le produit qu apr s avoir consulter son m decin et sous contr le m dical Effets collat raux Aucun effet collat ral significatif n est connu Dans certains cas chez des personnes particuli rement sensibles des rougeurs cutan es apparaissent apr s le traitement au niveau de l emplacement des lectrodes les rougeurs disparaissent normalement au bout de quelques minutes Si les rougeurs persistent consulter un m decin Da
88. lettrodi Gruppi Polpacci CH1 foto 13 con 2 elettrodi Tibiale anteriore CH2 foto 14 con due elettrodi muscolari Quadricipite CH3 foto 11 con 2 elettrodi Bicipite femorale CH4 foto 12 con 2 elettrodi Fase 1 Fase 2 Fase 3 20 min di contrazioni alternate su coppia canali 5 min Riscaldamento 9 S60 recupero 5 min Defaticante 7sec contrazione CH1 CH2 7sec contrazione CH3 CH4 IACER SRL MNPGO5 08 Ed 12 10 10 Pag 15 e MEDICAL DIVISION E02 Rassodamento Indicato per rassodare la muscolatura lavora prevalentemente sulle fibre lente Frequenza di trattamento 3 4 volte a settimana Intensita tale da produrre buone contrazioni ma non dolorose iniziando con 15mA aumentando gradualmente l intensit con l avanzare delle settimane Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi E02 Rassodamento Durata totale programma 30 minuti Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 NETTE d Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 Fase 4 10 min Allenamento 10 min Allenamento 5 min Riscaldamento 13 sec recupero 13 sec recupero 5 min Defaticante 7 sec
89. lgogenic substances So a vicious circle begins In addition to relieving pain TENS causes induced muscle stimulation increasing metabolic activity and blood flow and improving tissue oxygenation with an intake of nutritional substances So the positive effect can be amplified by combining TENS with muscle stimulation of the area concerned Position of electrodes and intensity levels The electrodes should be positioned to form a square surrounding the painful area using Channel 1 and Channel 2 as shown in illustration 1 red up black down are not important for therapeutic purposes follow instructions on electrodes position manual The intensity should be adjusted to a level between the thresholds of perception and thresholds of pain the maximum intensity level is the moment in which the muscles on the area treated begin to contract over this limit stimulation does not become more effective just more irritating illustration 1 Red Red Painful WARNING Channel 1 Channel 2 Create a square area with the area electrodes over the painful zone Keep 4cm minimum distance Black Black between electrodes A01 TENS rapid Medical program Program also called conventional tens used for analgesic purposes blocking pain at the dorsal horn of the spinal cord in accordance with the Gate Control Theory by Melzack and Wall Pain impulses leave part of the body for example the hand and run along the nerve tracts through sma
90. ll diameter nerve fibres until they reach the central nervous system where the impulses are interpreted as pain Conventional tens activates large diameter nerve fibres blocking the path of small diameter nerve fibres at the spinal cord So action is mainly taken against the symptom to simplify it further the wire transmitting pain information is obstructed Treatment duration should be no less than 30 40 minutes Conventional tens is a current that can be used to treat general everyday pain The average number required to benefit from the treatment is 10 12 once a day there are no contraindications for up to double this amount The program has a duration of 30 minutes in a single phase The program can be repeated at the end of the session for particularly persistent pain The nature of the impulse means that the patient may experience an addictive effect due to which the impulse will be felt less and less if necessary the intensity can be increased by one level to counter this effect Position of electrodes form a square over the painful area as shown in illustration 1 A02 TENS endorphinic Medical program This type of stimulation produces two types of effects according to how the electrodes are positioned positioning the electrodes in the dorsal region see photo 08 in the positions manual promotes the endogenous production of morphine like substances capable of raising the pain perception threshold positioning the electrodes to
91. lo Gli elettrodi vanno posti a quadrato delimitando l area da trattare l applicazione pud essere giornaliera e l intensit media Durata programma 30 minuti una fase Intensit di stimolazione suggerita media 15 30mA Posizione elettrodi fare riferimento alle posizioni da foto 01 a foto 20 e foto 22 e 23 E06 Microlifting Il seguente programma con una durata di 15 minuti in una sola fase viene utilizzato per tonificare i muscoli facciali attraverso un particolare impulso che migliora sia l aspetto estetico che dinamico dei muscoli facciali La posizione degli elettrodi indicata nelle foto delle posizioni elettrodi foto 24 N B mantenere una distanza minima di 3 cm tra elettrodo e bulbo oculare N IMPORTANTE attenzione alla regolazione dell intensit in quanto i muscoli facciali sono particolarmente sensibili si consiglia pertanto di regolare l intensit gradualmente partendo con un livello di stimolazione molto basso per esempio 3 5 per poi crescere con estrema cautela fino a raggiungere un buon livello di stimolazione rappresentato da una buona attivazione dei muscoli IMPORTANTE non necessario arrivare a livelli di intensit tali da procurare fastidio L equazione pi dolore pi beneficio del tutto fuorviante e controproducente Grandi ed importanti obiettivi si ottengono con costanza e pazienza E07 Massaggio relax Questo programma si adatta alle problematiche di tutti i giorni In a
92. lore il limite massimo di intensit rappresentato dal momento in cui la muscolatura circostante l area trattata inizia a contrarsi oltre questo limite la stimolazione non aumenta la sua efficacia ma solo il senso di fastidio quindi bene fermarsi prima di tale soglia numero di trattamenti per ottenere i primi benefici tra i 15 e i 20 con frequenza giornaliera proseguire nei trattamenti fino alla scomparsa dei sintomi Durata programma 30 minuti in una fase Posizione elettrodi fare riferimento alla posizione foto 28 A09 Distorsioni Contusioni Programma medicale Solo per modello T ONE EVO II Dopo questo tipo di infortuni sviluppa la sua efficacia con una azione inibitoria del dolore a livello locale Intensit regolata fra la soglia di percezione e la soglia del dolore Numero di trattamenti fino a riduzione del dolore con frequenza quotidiana anche 2 3 volte al giorno Descrizione programma con riferimento foto posizionamento elettrodi A9 Distorsioni Contusioni Durata totale programma 30 minuti Posizione elettrodi caviglia foto 32 Fase 1 Fase 2 Tens convenzionale 15 min Impulsi per ematomi 15 min IACER SRL 05 08 Ed 12 10 10 Pag 21 MEDICAL DIVISION 10 Antinfiammatorio Programma medicale Solo per modello T ONE EVO Il Programma consigliato negli stati infiammatori Applicazione fino alla riduzione dello stato infiammatorio Anche due appl
93. lsion onde carr e on obtient une action de drainage sur la zone traiter des impulsions de fr quences diff rentes drainent la zone des profondeurs diff rentes Intensit r gl e entre le seuil de sensibilit et le seuil douloureux Placement des lectrodes en forme de carr sur la zone traiter conform ment au sch ma n1 A14 Cutan o lastique seulement T ONE EVO II Ce traitement comprend 4 phases avec trois programmes diff rents pour vasculariser et tonifier les muscles en superficie Il procure galement un soulagement une douleur locale L intensit doit tre ajust e un niveau sup rieur au seuil de perception et inf rieur au seuil de douleur Placement des lectrodes en forme de carr sur la zone douloureuse conform ment au sch ma 1 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 10 min 10 min Vascularisation Tens impulsion br ve Tens wobbul Vascularisation 15 Pr vention atrophie programme m dicaux seulement T ONE EVO II Programme con u pour viter une fonte de la masse musculaire Pendant tout le traitement on privil gie le travail de tonicit musculaire en portant une attention particuli re aux fibres lentes Ce programme est sp cialement adapt la r ducation apr s une blessure ou apr s une op ration Il emp che la fonte de la masse musculaire en cas d inactivit physique On peut stimuler la zone musculaire avec des applications quot
94. mit de l sions ou de lac rations de la peau l est interdit de placer les lectrodes sur les sinus carotidiens carotide les parties g nitales ll est interdit de placer les lectrodes proximit des yeux et il ne faut pas exposer le bulbe oculaire au courant g n r une lectrode diam tralement oppos e l autre par rapport l oeil maintenir une distance minimum de 3 cm du bulbe oculaire Pour l utilisation des lectrodes suivre les indications report es dans ce manuel et sur la boite des lectrodes Utiliser des lectrodes mono patient fournies exclusivement par le producteur ou le revendeur et viter soigneusement l change d lectrodes entre les diff rents utilisateurs Utiliser uniquement les lectrodes fournies par le constructeur le dispositif est test et garanti pour l utilisation des lectrodes fournies Des lectrodes de section inad quate peuvent provoquer des r actions de la peau ou des br lures N utiliser les lectrodes rondes fournies que pour les applications sur le visage Ne pas utiliser les lectrodes si elles sont endommag es m me si elles adh rent bien la peau Il est interdit d utiliser l lectrode lorsqu elle n adh re plus la peau Une utilisation r p t e des m mes lectrodes peut compromettre la s curit de la stimulation En effet cela peut causer l apparition de rougeurs cutan es qui persistent plusieurs heures apr s la fin de la stimulation
95. mps Si l on ne doit pas utiliser T ONE pendant longtemps on recommande de recharger le piles et de conserver le T ONE au sec Chargement des piles Brancher le chargeur dans une prise de r seau 220 230 VAC Connecter le chargeur dans T ONE La dur e moyenne d un cycle de recharge complet varie de 8 10 heures Pendant la recharge les piles chauffent il s agit d un processus normal qui ne comporte aucun danger Ne pas se servir du chargeur e Sila fiche est endommag e ou s il y a des parties cass es e ila t expos la pluie ou tout autre liquide e S ila t endommag lors d une chute IACER SRL MNPGO5 08 Ed 12 10 10 Pag 62 Ne pas immerger le chargeur dans l eau Pour nettoyer le chargeur utilisez un chiffon sec Ne pas ouvrir le chargeur il ne contient aucune pi ce r parable 7 Entretien et conservation de T ONE Conditions de conservation et ou utilisation 1 Temp rature d emploi et de conservation 20 C 406 2 Humidit relative d emploi et de conservation 75 3 On conseille d teindre le T ONE la fin de chaque s ance Le T ONE devra tre conserv dans sa boite d emballage avec tous les accessoires fournies et plac dans un endroit s r l abri des situations cit es dans le chapitre 3 Avertissements 4 Nettoyage pour le nettoyage du dispositif utiliser exclusivement un chiffon sec 5 Le fabricant d conseille toute r paration du dispositif T ONE par un personnel non auto
96. mulation An audio signal will sound three times when the program has finished 9 At the end of the program switch off the T ONE and remove the cables Attach the electrodes to the transparent films and replace them in their original packaging Option to simultaneously increase the intensity on all channels Select the desired program Start program Increase each channel to at least intensity 1 A CH1 A CH2 A CH3 A CH4 Blue Yellow Red White To simultaneously increase the intensity of all channels use the following buttons P Increase GD Decrease IACER SRL 05 08 Ed 12 10 10 Pag 35 Skip phase press the 9 button during the working program to skip to the next phase Pause stop program during the working program press the O button once to momentarily pause the program Press the Oo button again to restart the program Switch off the machine to stop the program 7 Battery charging The display shows when the battery is low of power Insert the jack of the battery charger into its socket and plug the battery charger into the main power socket Recharge for 8 hours for a complete charge Do dot immerge the battery in water or other liquids and do not expose it to heat sources Do not dispose of dead or defective batteries with domestic waste dispose of in an authorised waste collection bin Before storing T ONE for long periods of time we recommend that it is fully charged and stored in
97. muscoli Se interviene stanchezza sospendere gli allenamenti per qualche giorno ed eseguire il programma S02 recupero muscolare Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi 506 Forza base Durata totale programma 30 minuti O Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 ti Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 Fase 4 10 min Allenamento 10 min Allenamento 5 min Riscaldamento 13 sec recupero 14 sec recupero 5 min Defaticante 7 sec contrazione 6 sec contrazione 507 Forza veloce Questo programma stato studiato per favorire l incremento della velocit in atleti che gia dispongono di questa qualit e per svilupparla in quegli atleti che ne sono carenti L esercizio assume un ritmo incalzante la contrazione breve ed breve anche il recupero Normalmente bene aver concluso un ciclo di tre settimane di forza base ad intensit crescente Continuare poi con tre settimane di forza veloce tre volte a settimana con intensit di stimolazione alta durante la contrazione 30 50mA Descrizione programmi gruppi muscolari
98. muscolo deve lavorare senza essere affaticato S01 Riscaldamento Durata totale programma 28 minuti Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 Ve AN NC ae fl d Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 3 min Riscaldamento 5 min Riscaldamento 20 in Allenamento 20 sec recupero 10 sec contrazione a bassa frequenza media frequenza 502 Recupero muscolare Da utilizzare in tutti gli sport dopo le gare gli allenamenti pi duri particolare dopo sforzi prolungati ed intensi Da utilizzare immediatamente dopo lo sforzo Favorisce l azione di drenaggio e capillarizzazione migliorando l ossigenazione del muscolo e favorendo lo smaltimento delle sostanze di sintesi prodotte durante lo sforzo Durata programma 15 min una fase Intensita di stimolazione medio bassa 15 25mA con incremento negli ultimi 5 min Posizione elettrodi fare riferimento alle posizioni da foto 01 a foto 20 503 Capillarizzazione Il programma di capillarizzazione produce un forte aumento della portata arteriosa nell area trattata L utilizzo prolungato di questo programma determina uno sviluppo della rete di capillari intramuscolari
99. n rectangulaire sym trique compens e Fr quence impulsions de 1 Hz 150 Hz Largeur d impulsion de 40us 8005 somme des deux demi impulsions Ecran digital LCD graphique 128x64 pixel r flecteur Commandes clavier en gomme silicone soft touch 10 touches Dimensions mm 125 x 76 x 34 Poids 280g y compris les piles Manutention et conservation se r f rer aux indications contenues dans le chapitre 7 Manutention et conservation de T ONE Attention l appareil fourni un courant sup rieur 10 mA C 0476 Produit conforme la directive 93 42 CEE concernant des applications de type m dical et successive modifications Dir 2007 47 CE IACER SRL MNPGO5 08 Ed 12 10 10 Pag 79 17 Assistance Le fabricant l exclusivit en ce qui concerne les interventions d assistance technique sur l appareil Pour toutes les interventions d assistance technique s adresser au Distributeur National ou le fabricant LACER S r l Via S Pertini 24 a 30030 Martellago VE Italie Tel 39 0415401356 Fax 39 0415402684 www iacer it e iacer iacer it Une ventuelle documentation technique concernant les pi ces r parables peut tre fournie mais seulement moyennant l autorisation pr alable de la soci t et uniquement apr s avoir fourni les instructions n cessaires au personnel pr pos aux interventions a T ONE Tous droits r serv s Le logo owision est la propri t excl
100. n and around the treated muscle fibres and create rhythmic contractions facilitating the discharge of algogenic substances and promoting lymphatic activity They can also be applied to older people to improve blood and lymphatic circulation The programs produce sequential tonic contractions in phases 2 and 3 that reproduce the typical effect of electronic lymphatic drainage However in this case unlike the lipolysis program the contractions are sequential first CH1 then CH2 CH3 and CH4 There are no real limits of application for these programs which can be practiced until the desired result has been achieved Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness 20 30 mA The first results can usually be seen after 3 4 weeks of practicing 4 5 sessions a week E09 Drain up Total duration 25 minutes Muscles All the muscles you want to stimulate in a sequence Connect a channel to each muscle that you want to stimulate Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 3 min warm up Alternated contraction on Alternated contraction on 2 min recovery 4 channel 6 sec each 4 channel 6 sec each 13 T E N S rehabilitation programs N WARNING It must be remembered that an electronic stimulator is a very effective analgesic instrument and that pain can indicate various types of medical conditions The Tens1 to Tens20 programs
101. ns certains cas rares la stimulation effectu e le soir provoque un retardement de l endormissement Dans ce cas suspendre le traitement et consulter un m decin 3 Avertissements T ONE a t con u et r alis pour fonctionner seulement avec des batteries Ni Mh 1600mAh 4 8V Le dispositif ne peut tre utilis par des patients reli s des appareils m dicaux Ne pas utiliser T ONE avec des appareils d lectrochirurgie ou de traitement ondes courtes ou micro ondes IACER SRL 05 08 Ed 12 10 10 Pag 57 Son emploi est d conseill aux personnes sous tutelle qui souffrent de troubles de la sensibilit aux personnes momentan ment atteintes d invalidit si elles ne sont pas assist es d une personne qualifi e ex le m decin ou le th rapeute est d conseill d utiliser le dispositif s il pr sente des signes d usure Si des substances trang res devaient p n trer dans le dispositif contacter imm diatement le revendeur ou le producteur En cas de chute v rifier qu aucune fissure ou l sion de tout genre ne se soit produite sur la boite Si le r cipient pr sente des fissures ou des l sions de tout genre contacter le revendeur ou le producteur En cas de variation des prestations durant le traitement interrompez le imm diatement et adressez vous imm diatement au revendeur ou au producteur m me le patient en traitement aupr s du centre de soins doit tre mis au courant est d
102. nto rosso in alto nero in basso indifferente ai fini della terapia seguire le indicazioni nel manuale posizionamento elettrodi Intensit regolata fra la soglia di percezione e la soglia del dolore il limite massimo di intensit rappresentato dal momento in cui la muscolatura circostante l area trattata inizia a contrarsi oltre questo limite la stimolazione non aumenta la sua efficacia ma solo il senso di fastidio quindi bene fermarsi prima di tale soglia rossa rossa IMPORTANTE zona Applicare gli elettrodi formando un quadrato sopra la zona dolente canale 1 dolore canale 2 mantenendo una distanza minima di 4cm tra un elettrodo e l altro clip nera clip nera A01 TENS rapido Programma medicale Programma detto anche tens convenzionale utilizzato a scopo antalgico la sua azione quella di indurre nell organismo un blocco del dolore a livello spinale secondo quanto sostenuto dalla teoria del cancello di Melzack e Wall Gli impulsi dolorifici che partono da un determinato punto del corpo ad esempio una mano percorrono le vie nervose attraverso fibre nervose di piccolo diametro fino a raggiungere il sistema nervoso centrale dove l impulso viene interpretato come doloroso La Tens convenzionale attiva fibre nervose di grosso diametro che a livello spinale bloccano il percorso delle fibre di piccolo diametro E dunque una azione prevalentemente sul sintomo per semplificare ulteriormente viene occluso il
103. o liquidi infiammabili e o gas infiammabili non utilizzare con apparecchi di elettrochirurgia o di terapia ad onde corte o microonde apparecchio adatto per funzionamento continuo 4 canali completamente indipendenti ed isolati galvanicamente 218mA di potenza massima picco picco 31mA max efficaci per singolo canale con carico da 200 ohm a 1000 ohm rettangolare bifasico compensato funzionamento con gamma impulsi da 1 Hz a 150 Hz da 40us a 800us somma dei due semimpulsi display LCD grafico 128x64 pixel riflettivo tastiera in gomma siliconica soft touch a 10 tasti mm 125 x 76 x 34 280gr batterie incluse fare riferimento alle indicazioni riportate al capitolo 8 Manutenzione e conservazione di Attenzione l apparecchio eroga corrente superiore a 10mA C 0476 Prodotto conforme alla direttiva 93 42 e successive modifiche 2007 47 CE 18 Garanzia cartolina azzurra da compilare e spedire T ONE coperto da garanzia di anni 2 a decorrere dalla data di acquisto sulle parti elettroniche La batteria e i cavi di connessione sono coperti da garanzia di 6 mesi le parti soggette ad usura elettrodi sono esclusi dalla garanzia La garanzia decade in caso di manomissione dell apparecchio ed in caso d intervento sullo stesso da parte di personale non autorizzato dal costruttore o dal rivenditore autorizzato Le condizioni di garanzia sono quelle descritte tra le Norme di garanzia SPEDIRE LA CA
104. o produce light muscle contractions in the first 2 3 weeks Increase intensity progressively over the next 3 4 weeks Application on alternate days Position of electrodes from photo 1 to photo 20 Program duration 30 minutes A16 Atrophy Total duration 30 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Ve AN NC ae t d Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 25 min 3 min warm up 6 sec Recovery 2 min recovery 6 sec contraction 14 SET UP Selecting the language and contrast level on the display Press the ON OFF button and hold it down until the language list appears on the display Release the buttons now use the mouse to move the cursors and choose the desired language or the level of contrast on the display Select the chosen language by using the LW buttons R S Adjust the level of contrast on the display by using the g 9 buttons Press to confirm your selections IACER SRL 05 08 Ed 12 10 10 Pag 51 15 Self adhesive electrodes The position of the electrodes is shown in the manual of electrode positions The electrodes supplied are top quality pre gelled and ready for use t
105. odes as shown in the photo 3 increase the intensity until the impulse can be felt use a low intensity for the first session to help you to understand how the machine works 4 during the program and over the next few days the intensity should be increased gradually so that muscle contractions are not painful 5 during contraction generated by the unit contract the muscle voluntarily 6 a cycle of 15 20 applications must be completed before the first results can be seen one application for each muscle every two days with a day of rest in between It is possible to work on pairs of muscles for example thighs and abdominal muscles treating thighs one day and abdominal the next day Working on too many muscles at the same time is not recommended E03 Tonification Total duration 34 minutes O Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 Ue AN Mea t d Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 12 min 12 min 5 min warm up 13 sec recovery 13 sec recovery 5 min recovery 7 sec contraction 7 sec contraction E04 Definition Indicated for defining muscles working mainly on explosive fibres Suitable for people who
106. on active ri un MM Cana ed tab en marche erreur lectrodes EN OW OFF non branch es Valeur en mA nni GU de l intensit f gt 170 6 1185 de sortie GE Indication du canal non actif DS L illustration a seulement but explicatif et ne repr sente les caract ristiques du programme S10 Pendant le fonctionnement de l lectrostimulateur une barre appara t sur l cran qui indique quand commence et s ach ve la contraction Les p riodes de contraction musculaire et les p riodes de r cup ration sont visualis s graphiquement gr ce un curseur sous la barre qui indique barre en tirets pour la r cup ration barre pleine pour la contraction et barre en pointill quand les contractions s enchainent entre les canaux UN MR 8 A la fin de la premi re phase T ONE annule l intensit pr c demment s lectionn e en avisant l utilisateur par un signal intermittent pour poursuivre le programme appuyer nouveau sur la touche des canaux IACER SRL 05 08 Ed 12 10 10 Pag 61 ll SCH MEDICAL DIVISION 9 Une fois le programme achev teindre T ONE et ter les c bles Coller les lectrodes sur les pellicules transparentes et les replacer dans leur housse Option pour augmenter simultan ment l intensit sur tous les canaux S lectionner le programme souhait Mise en route du programme R gler l intensit au moins jusqu 1 pour chaque canal A C
107. onare gli elettrodi in prossimit di aree soggette a stati infiammatori Intensit regolata in modo da produrre una buona sollecitazione della parte stimolata 10 20mA la sensazione deve essere simile ad un massaggio A03 TENS a scansione Programma medicale L azione molto simile a quella del programma A01 In questo programma vengono variati durante la stimolazione frequenza e larghezza impulso al fine di contrastare l assuefazione alla stimolazione non saranno richiesti continui incrementi di intensit Selezionare l intensit all inizio del programma e mantenerla fino alla fine Pu accadere che durante il programma la percezione della corrente quasi scompaia in questo caso non aumentare l intensit e attendere la fine La TENS sta svolgendo la sua funzione La durata di 20 minuti una fase Intensit appena sopra la soglia di percezione Posizione elettrodi formando un quadrato sopra la zona dolente come figura 1 o fare riferimento alle posizioni da foto 25 a foto 33 A04 TENS ai valori massimi Programma medicale Durata brevissima 3 minuti con una fase Produce un blocco periferico degli impulsi dolorifici causando un vero e proprio effetto anestetizzante locale E un tipo di stimolazione adatto in situazioni di traumi o contusioni in cui necessario intervenire con rapidit L intensit selezionata quella massima sopportabile ben oltre il limite della tens convenzionale quindi con vistosa contrazione d
108. ono costruiti in conformit alla Direttiva 93 42 CEE del Consiglio del 14 Giugno 1993 concernente i dispositivi medici D Lgs 46 97 del 24 Febbraio 1997 Attuazione della Direttiva 93 42 CEE concernente i dispositivi medici cosi come modificata dalla Direttiva 2007 47 CE del 5 Settembre 2007 D Lgs 37 2010 del 25 Gennaio 2010 dispositivi TONE EVO e T ONE EVO II sono dispositivi in classe Ila secondo l allegato IX regola 9 della Direttiva 93 42 e successive modifiche Martellago 29 03 2010 Il rappresentante legale Mario Caprara IACER SRL MNPGO5 08 Ed 12 10 10 Pag 24 17 Caratteristiche tecniche Classe di rischio Classe isolamento Classificazione Contenitore Alimentazione Caricabatteria Consumo medio Limitazioni Funzionamento Canali di uscita Corrente erogata Tipo di impulso Frequenza Ampiezza impulsi Visualizzazione Comandi Dimensioni Peso Manutenzione e conservazione Ila in accordo con la direttiva 93 42 CEE e successive modifche apparecchio alimentato internamente di classe con parti applicate di tipo BF in accordo con le normative CEI EN 60601 1 IP30 in base alla penetrazione dei liquidi e della polvere apparecchio non protetto ABS batteria interna Ni Mh 4 8V 1600mA modello XKD C0300NHS6 0 5W input 100 240 VAC 50 60Hz output 6 VDC 300mA 1W Apparecchio non adatto a funzionare in ambienti con alte concentrazioni di ossigeno e
109. ono utilizzati impulsi elettrici specifici L intensit della stimolazione rappresentata sul visore di T ONE per ogni canale con una scala crescente da 0 a 120 Nei programmi Sport e Beauty l intensit si differenzia a seconda del tipo di muscolo o programma utilizzato specifichiamo ora come stabilire la giusta intensit a seconda dell impulso utilizzato Le tipologie di impulsi possono essere cosi suddivise 1 Impulso di riscaldamento in questo caso sar necessario produrre una stimolazione con intensit a crescita graduale in modo da innalzare gradualmente il metabolismo del muscolo trattato Un po quello che succede con la propria autovettura prima di portarla ai massimi regimi di giri bisogna riscaldare il motore Impulso di contrazione tonificante allenante amiotrofia durante l impulso allenante il muscolo trattato dovr produrre delle vistose contrazioni Si noter anche ad occhio nudo come il muscolo tenda ad irrigidirsi e crescere di volume Si consiglia di alzare l intensit gradualmente nella prima contrazione per individuare un giusto comfort di stimolazione Nella seconda contrazione allenante si alzer ulteriormente l intensit fino a raggiungere la soglia soggettiva di sopportazione questa operazione andr ripetuta di contrazione in contrazione fino a portare il carico di lavoro ai livelli di intensit consigliati nella descrizione dei singoli programmi Si consiglia inoltre di annotare le intensit raggi
110. ontractions Total duration 25 minutes Muscles all the muscles you want to stimulate in a sequence Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 3 min warn 6 sec Sequential 6 sec Sequential Smin fecola H contractions on the 4 contractions on the 4 y channels channels IACER SRL 05 08 Ed 12 10 10 Pag 42 12 Beauty programs E01 Lipolysis This specific drainage program increases microcirculation within and around the muscle fibres treated and creates rhythmic contractions facilitating the discharge of algogenic substances and promoting lymphatic activity It can also be applied to older people to improve blood and lymphatic circulation The program produces sequential tonic contractions before CH1 2 after CH3 4 reproducing the typical effect of electronic lymphatic drainage There are no real limits of application for this program which can be practiced until the desired result has been achieved Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness Duration 30 minutes The first results can usually be seen after 3 4 weeks practicing 4 5 sessions a week The programme produces sequential tonic contractions in the central work phase first CH1 CH2 then CH3 CH4 this is known as electronic lymphatic drainage The electrodes should be applied as follows CH1 CH2 on the extremities of the limbs e g calf or forearm
111. ormance 5 Massage winding down active recovery impulse intensity must be adjusted gradually to massage the muscle treated The level of intensity should be sufficient to obtain a comfortable massage There is no need to endure high intensity levels in this case as it is meant to be a massage meaning that intensity can be increased gradually without excesses 6 impulse increase the intensity gradually to produce constant visible stimulation of the area treated a medium stimulation threshold is recommended always below the pain threshold 11 Sports programs N IMPORTANT Stimulation intensity the sports programs Resistance Strength Agonist Antagonist are divided into warm up phases work phases and recovery phases During the warm up phase phase 1 the stimulation intensity should be adjusted to produce a slight tickling sensation in the treated muscle this should be enough to warm up the muscle without tiring it 18 30 mA During the work phases the central phases of the programs contraction impulses are alternated with active recovery impulses The user needs to select the two intensities separately for the contraction the user should see the following on the display with a bold bar 20 30 mA for relatively unfit people 30 50 mA for fit people and more than 50 mA for very fit people We recommend adjusting the intensity of the recovery phase between one contraction and another by appro
112. osizionamento elettrodi S08 Forza esplosiva Durata totale programma 28 minuti O Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 ti Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 Fase 4 10 min Allenamento 10 min Allenamento 3 min Riscaldamento 24 sec recupero 24 sec recupero 5 min Defaticante 6 sec contrazione 6 sec contrazione 59 Resistenza Il programma Resistenza viene utilizzato in ambito sportivo per incrementare la capacit di resistenza muscolare con un lavoro prevalente sulle fibre lente Programma indicato per gli sport di resistenza maratoneti fondisti ironman etc Intensit di stimolazione durante la contrazione seguire le indicazioni riportate all inizio del presente capitolo per i programmi Sport Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi S09 Resistenza Durata totale programma 50 minuti Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale fo
113. oxygenation and helping to discharge synthetic substances produced during exertion Program duration 15 minutes Stimulation intensity medium low increased during the last 5 minutes Position of electrodes see photos 01 to 20 in the manual of positions in relation to the area that you wish to stimulate 503 Capillarization The capillarization program significantly increases arterial flow in the area treated The capillarization program is very useful for recovering after intense aerobic work toning up training and improves local microcirculation Program duration 30 minutes Recommended stimulation intensity medium 20 30mA Position of electrodes see photos 01 to 20 in the manual of positions 504 Competitive Counteractive Agonist Antagonist The electronic stimulator produces contractions alternated between 4 channels during the first 3 minutes of warm up the 4 channels work simultaneously during the second work phase 20 minutes muscle contractions are alternated between Channel 1 2 agonist muscles and Channel 3 4 antagonist muscles The program is designed to restore muscle tone to the quadriceps and its antagonist the leg biceps or the biceps brachii and the triceps The work aims at developing strength With this program muscle relaxation is obtained by simultaneous stimulation from 4 channels during the last 10 minutes phase 3 Stimulation intensity during the contraction enough to produce good muscle contraction
114. oyenne 15 25mA mais elle doit tre augment e au cours des 5 derni res minutes Placement des lectrodes cf guide du placement des lectrodes de la photo n la photo n20 503 Capillarisation Le programme de capillarisation produit une forte augmentation du d bit art riel dans la zone trait e L utilisation prolong e de ce programme d veloppe le r seau capillaire intramusculaire des fibres rapides et augmente ainsi leur capacit supporter des efforts prolong s plus longtemps Chez un sportif ayant une bonne r sistance ce programme est tr s utile tant pour la r cup ration apr s des s ances intenses de travail a robic qu avant des s ances de travail ana robie ainsi que dans le cas d une interruption de l entrainement mauvais temps IACER SRL MNPGO5 08 Ed 12 10 10 Pag 65 accidents Dur e du programme 30 minutes une phase Intensit de stimulation conseill e en moyenne 20 30 Placement des lectrodes cf guide du placement des lectrodes de la photo n4 la photo n20 504 Muscles agonistes Muscles antagonistes L lectrostimulateur produit des contractions alternatives sur les 4 canaux durant la phase 1 d chauffement les 4 canaux travaillent en m me temps durant la phase 2 de travail on alterne les contractions musculaires d abord sur les canaux 1 et 2 muscles agonistes et ensuite sur les canaux 3 et 4 muscles antagonistes C est un programme tudi pour renforcer les muscles du
115. pecifications Page 52 18 Assistance Page 53 IACER SRL 05 08 Ed 12 10 10 Pag 30 1 Presentation Thank you for choosing the T ONE electronic stimulator this excellent medical device has been developed using modern and innovative technology designed by a leading ltalian company in the design and manufacture of professional electronic stimulators and surface electromyographs T ONE EVO I 11 Programmi Sport 9 Programmi Beauty 5 Programmi TENS T ONE EVO Il 11 Programmi Sport 9 Programmi Beauty 16 Programmi TENS 2 T ONE kit contents 1 T ONE electronic stimulator 4 two connection cables for the transmission of electric impulses 2 pkgs containing 4 pre gelled self adhesive 41x41 mm electrodes 1 for T ONE EVO 1 2 pkgs containing 4 pre gelled self adhesive 40x80 mm electrodes 1 for T ONE EVO I 1 pkg containing 8 pre gelled diam 32mm self adhesive electrodes not available on T ONE EVO 1 1 battery charger 1 T ONE user manual 1 electrode position manual 1 carry bag Accessories Pre gelled electrodes 41x41mm 48X48mm 40x80 mm 50x90mm diam 32mm Reusable elastic belts for limbs and calves Electrotherapy gel 3 Purpose The T ONE electronic stimulator is a medical device specifically intended for adults with adequate knowledge of the device acquired from reading the manual for domestic use T ONE is used to apply electrical microimpulses capable of producing energy to the
116. photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 H LE Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 Phase 4 10 min 8 min 3 min warm up 14 sec recovery 10 sec recovery 5 min recovery 6 sec contraction 5 sec contraction 508 Explosiveness explosive strength Explosive strength programs increase the explosive power and speed of the muscle mass with extremely short strengthening contractions and very long active recovery times to allow the muscle to regain strength Complete a three week basic strength cycle 506 before using this program Then continue with three weeks of explosive strength twice a week During the contraction the intensity must be the highest that can be endured in order to obtain maximum muscle exertion whilst involving the greatest number of fibres over 35mA S08 Explosive strenght Total duration 28 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 H LE Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1
117. ple la cuisse ou le biceps brachial IACER SRL 05 08 Ed 12 10 10 Pag 69 Intensit de stimulation elle doit produire de bonnes sollicitations indolores des zones stimul es 15 30mA E01 Lipolyse Temps total du programme 30 minutes Groupes Extenseurs d main CH1 photo 04 2 lectrodes Extenseurs d main CH2 photo 05 2 lectrodes musculaires Biceps brachial CH3 photo 02 2 lectrodes Triceps CH4 photo 03 2 lectrodes Groupes Mollets CH1 photo 13 2 lectrodes Jambier ant rieur CH2 photo 14 2 lectrodes musculaires Quadriceps CH3 photo 11 2 lectrodes Biceps cruraux CH4 photo 12 2 lectrodes Phase 1 Phase 2 Phase 3 20 min de contractions en couple de canaux 6 sec r cup ration 7sec contraction CH1 CH2 7sec contraction CH3 CH4 5 min chauffement 5 min d fatiguant 02 Raffermissement Indiqu pour raffermir les muscles cible principalement les fibres lentes Adapt ceux qui n ont jamais fait d activit physique ou qui sont inactifs depuis longtemps Conseils d utilisation 7 Choisir le muscle traiter Pour obtenir de bons r sultats il est recommand de ne traiter qu un nombre limit de muscles la fois selon le processus d crit ci apr s 8 Positionner les lectrodes comme montr sur la photo 9 Augmenter l intensit jusqu au seuil de perception utiliser une intensit faible pour la premi re s ance afin de comprend
118. polpacci Gel per elettroterapia 3 Destinazione d uso L elettrostimolatore T ONE un elettrostimolatore per uso estetico e sportivo Esso trova applicazioni anche nel trattamento di muscoli affaticati dopo gare un valido coadiuvante nel trattamento delle gambe pesanti anticellulite drenaggio defaticante rilassante suo impiego indicato per il professionista per il preparatore atletico per gli operatori professionali presso centri di estetica Ne previsto l uso anche in ambito domestico da parte di persone adulte adeguatamente istruite attraverso la lettura del manuale Il costruttore consiglia che i programmi di TENS siano eseguiti sotto controllo medico Controindicazioni Vietato l uso ai portatori di pace maker cardiopatici epilettici donne in stato di gravidanza persone con flebiti in atto con stati febbrili con tromboflebiti persone ansiose in presenza di gravi malattie In presenza di traumi stress muscolari o qualsiasi altro problema di salute utilizzare il prodotto solo dopo aver consultato il proprio medico e sotto controllo medico Effetti collaterali Non sono noti significativi effetti collaterali In alcuni casi di persone particolarmente sensibili dopo il trattamento si manifestano degli arrossamenti cutanei in corrispondenza degli elettrodi l arrossamento scompare normalmente pochi minuti dopo il trattamento Se l arrossamento persiste consultare un medico In rari casi la stimolazione ser
119. presentato dal momento in cui la muscolatura circostante l area trattata inizia a contrarsi E consigliabile non andare oltre tale limite IACER SRL MNPGO5 08 Ed 12 10 10 Pag 10 11 Programmi Sport N IMPORTANTE Intensita di stimolazione i programmi sport Resistenza Forza Agonista Antagonista sono suddivisi in fase di riscaldamento fasi di lavoro fase defaticante Durante la fase di riscaldamento fase 1 l intensit di stimolazione va regolata in modo da produrre una discreta sollecitazione del muscolo trattato tale da poter riscaldare senza affaticare 18 30mA Durante le fasi di lavoro le fasi centrali dei programmi vengono alternati impulsi di contrazione e di recupero attivo E necessario selezionare separatamente le due intensit per la contrazione visualizzata sul display dalla barra piena 20 30mA per persone poco allenate 30 50mA per persone allenate oltre 50mA per persone molto allenate Si consiglia di regolare l intensit di recupero tra una contrazione e l altra circa il 15 2096 in meno dell intensit di contrazione Durante la fase defaticante l ultima fase l intensit deve essere regolata in modo da produrre un buon massaggio della parte stimolata senza produrre dolore 18 30mA 501 Riscaldamento Programma da utilizzare prima di una sessione di allenamento o competizione utilissimo negli Sport con sforzo massimo fin dalle prime battute Intensit di stimolazione media 20 30 il
120. r c dent la fr quence de stimulation employ e dans la phase de contraction est plus lev e et elle est donc parfaitement adapt e pour un travail sur les fibres rapides 11 R activation Temps total du programme 25 minutes Groupes musculaires programme concerne tous les muscles que l on veut stimuler Phase 1 Phase 2 Phase 3 Phase 4 10 minutes de contractions 10 minutes de contractions 3 min chauffement en s rie sur les 4 canaux en s rie sur les 4 canaux 2 min d fatiguant dur e impulsion 6 sec dur e impulsion 6 sec 11 Programmes Beauty E01 Lipolyse Ce programme est tr s utilis dans le domaine esth tique et il est indiqu pour les zones qui pr sentent des accumulations de graisse car il agit en augmentant la micro circulation sanguine et en favorisant l activit lymphatique Il permet d augmenter consid rablement le m tabolisme local grace une action trophique il favorise la diminution de l effet corce d orange Le tout avec l aide d un r gime alimentaire hypocalorique Il peut tre appliqu tous les jours Dans la phase de travail interm diaire ce programme produit des contractions toniques s quentielles d abord CH1 CH2 puis CH3 CH4 le pr cieux drainage lymphatique lectronique Il est donc logique d appliquer les lectrodes comme suit CH1 CH2 aux extr mit s des membres par exemple le mollet ou l avant bras et CH3 CH4 dans la partie sup rieure par exem
121. rculation within and around the muscle fibres treated creating rhythmic contractions fostering better drainage and toning It can also be applied to older people to improve blood and lymphatic circulation in the lower limbs e g applying CH1 to the right calf CH2 to the right thigh CH3 to the left calf CH4 to the left thigh This program can be carried out using self adhesive electrodes Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness It mainly works on slow twitch fibres Total duration 25 minutes 510 Tonic contractions Muscles all the muscles you want to stimulate in a sequence Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 3 min warm up 6 sec Sequential 6 sec Sequential 2 min recovery contractions on the 4 contractions on the 4 channels channels 11 Phasic contractions sequential This program produces rhythmic contractions with a stimulation frequency typical of fast twitch fibres It is suitable for increasing muscle strength sequentially The program produces sequential phasic contractions on 4 channels Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness Unlike the previous program this one uses a higher stimulation frequency during the contraction phase and therefore works mainly on fast twitch fibres 11 Phasic c
122. re comment l appareil fonctionne 10 Pendant les premi res s ances l intensit doit tre augment e tr s progressivement pour que les contractions musculaires ne soient pas douloureuses 11 Pendant la contraction musculaire induite par l appareil contracter le muscle volontairement 12 Un cycle de 15 20 s ances est n cessaire pour obtenir les premiers r sultats une s ance sur chaque muscle tous les deux jours avec un jour de repos entre deux Il est possible de travailler sur une paire de muscles par exemple cuisses et abdominaux en ciblant les cuisses un jour et les abdominaux le jour suivant n est pas recommander de travailler sur un grand nombre de muscles simultan ment E02 Raffermissement Temps total du programme 30 minutes Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Ue nu oe ae Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 3 Phase 4 10 min entrainement 10 min entrainement 5 min chauffement 13 sec r cup ration 13 sec r cup ration 5 min d fatiguant 7 sec contraction 7 sec contraction E03 Tonification Les programmes de tonification permettent a la musculatur
123. ria sulla presa domestica 220 230 VAC e collegare lo spinotto del caricabatteria alla presa del T ONE posta in alto a destra del display e tempo medio per il ciclo di ricarica completo varia dalle 8 alle 10 ore e durante la carica la batteria ed il caricabatteria si scaldano si tratta di un processo normale e non comporta pericoli N IMPORTANTE scollegare il caricabatteria dalla rete quando non in funzione Non usate il caricabatteria se e La spina danneggiata o ci sono parti rotte e E stato esposto alla pioggia o a qualsiasi altro liquido e componenti hanno subito danni in una caduta Non immergere il caricabatteria nell acqua Per la pulizia del caricabatteria usare un panno asciutto Non aprire il caricabatteria esso non contiene parti riparabili N IMPORTANTE scollegare gli elettrodi durante la fase di ricarica delle batterie IACER SRL MNPGO5 08 Ed 12 10 10 Pag 8 8 Manutenzione e conservazione di T ONE Si consiglia di spegnere alla fine di ogni seduta T ONE oltre a togliere i cavi dagli appositi connettori T ONE dovr essere conservato all interno della confezione insieme a tutti gli elementi di cui dotato riposto con cura su di un piano sicuro ed al riparo da situazioni elencate nel paragrafo Avvertenze T ONE va conservato alle seguenti condizioni Temperatura 220C a 40 C Umidit relativa massima 75 Pressione atmosferica da 700 hPa a 1060 hPa Pulizia per la puliz
124. ris par l entreprise Dans ce cas chaque intervention de la part de personnel non autoris par le fabricant sera consid r e comme un endommagement du dispositif de cette facon le constructeur n est plus engag par la garantie et il n est pas responsable de tous les dangers dans lesquels l utilisateur peut encourir 6 11 est recommand de v rifier le bon fonctionnement de l appareil chez le constructeur ou le concessionnaire tous les 2 ans 7 Les piles d charg es doivent tre jet es dans les r cipients appropri s ou limin es selon les normes l gislatives en vigueur 8 Ne pas laisser l int rieur de T ONE les piles d charg es car l acide corrosif pourrait sortir et endommager irr m diablement l lectrostimulateur 9 Avant de ranger T ONE pour une longue p riode il est conseill d enlever les piles de l emplacement 8 R solution de probl mes Seuls le fabricant ou le vendeur autoris pourront effectuer des r parations sur T ONE T ONE ne s allume pas e S assurer que les piles sont bien leur place Essayer de recharger les piles et ensuite tenter nouveau d allumer l appareil e S assurer que l on a appuy correctement sur la touche d allumage au moins pendant une seconde T ONE ne transmet pas d impulsions lectriques e S assurer que l on a bien reli les c bles aux lectrodes et que l on a enlev le plastique qui prot ge les lectrodes e S assurer que les c bles sont branch s corre
125. siderando che le contrazioni sono in sequenza sui 4 canali Fase 1 Fase 2 Fase 3 Fase4 pm 10 min di contrazioni in 10 min di contrazioni in 7 3 Riscaldamento sequenza sui 4 canali sequenza sui 4 canali 2 min Defaticante 13 Programmi T E N S riabilitazione J N ATTENZIONE Va ricordata la grande dell elettrostimolatore come strumento antalgico la funzione del dolore come indicatore di patologie a vario La maggior parte dei programmi del presente paragrafo da A1 ad A16 hanno natura antalgica Si raccomanda di leggere attentamente il manuale prima di utilizzare T ONE RICORDATE CHE IL DOLORE E UN SEGNALE prima di utilizzare T ONE individuare la patologia con l ausilio del medico La TENS acronimo che indica stimolazione nervosa elettrica transcutanea una tecnica terapeutica utilizzata con prevalente finalit antalgica per contrastare gli effetti tipicamente dolore provocati dalle patologie pi svariate In questa accezione ha trovato applicazioni nel trattamento degli inconvenienti che quotidianamente affliggono il genere umano dolori cervicali artrosi mialgie nevriti dolori alla schiena periartriti pesantezza alle gambe debolezza muscolare solo per citarne alcuni IACER SRL MNPGO5 08 Ed 12 10 10 Pag 18 A livello accademico la TENS viene distinta in diverse categorie secondo il meccanismo che coinvolge per ottenere l effetto di
126. souhaite sculpter leurs muscles Conseils d utilisation 1 2 3 4 5 6 Choisir le muscle traiter Pour obtenir de bons r sultats il est recommand de ne traiter qu un nombre limit de muscles la fois selon le processus d crit ci apr s Positionner les lectrodes comme montr sur la photo Augmenter l intensit jusqu au seuil de perception utiliser une intensit faible pour la premi re s ance afin de comprendre comment l appareil fonctionne Pendant les premi res s ances l intensit doit tre augment e tr s progressivement pour que les contractions musculaires ne soient pas douloureuses Pendant la contraction musculaire induite par l appareil contracter le muscle volontairement Un cycle de 15 20 s ances est n cessaire pour obtenir les premiers r sultats une s ance sur chaque muscle tous les deux jours avec un jour de repos entre deux Il est possible de travailler sur une paire de muscles par exemple cuisses et abdominaux en ciblant les cuisses un jour et les abdominaux le jour suivant n est pas recommander de travailler sur un grand nombre de muscles simultan ment E04 D finition Temps total du programme 25 minutes A O Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessi
127. t tous groupes musculaires Programme utilise avant un entrainement ou une comp tition tr s utile pour les sports n cessitant une mise en action tr s rapide Dur e du programme 28 minutes Positions des lectrodes de la photo 1 la photo 20 Intensit de stimulation recommand e medium 20 30mA le muscle doit travailler sans effort 501 Echauffement Temps total du programme 28 minutes Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Fl chisseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Quadriceps cuisses photo 11 18 cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 4 3 min Echauffement basse 5 min Echauffement fr quence 5 min d fatiguant fr quence moyenne 502 R cup ration musculaire A utiliser dans tous les sports apr s les comp titions ou les entra nements les plus durs en particulier apr s des efforts prolong s et intenses A utiliser imm diatement apr s l effort Favorise l action de drainage et de capillarisation en am liorant la diffusion de l oxyg ne dans le muscle et en permettant l limination des substances de synth se produites durant l effort Dur e du programme 15 minutes une phase Intensit de stimulation en m
128. t chapitre concernant les programmes Sport S09 R sistance Temps total du programme 50 minutes Biceps photo 02 15 Triceps photo 03 16 Extenseurs de la main photo 04 Extenseurs de la main photo 05 Deltoide photo 06 Abdominaux photo 01 20 Grand pectoral Poitrine photo 07 17 Trap ze photo 08 Grand dorsal photo 09 Fessiers photo 19 Ve AN oe ae Quadriceps cuisses photo 11 18 Biceps cruraux photo 12 Mollets photo 13 Jambier ant rieur photo 14 Phase 1 Phase 2 Phase 3 Phase 4 20 min entrainement 20 min entrainement 5 min chauffement 20 sec r cup ration 22 sec r cup ration 5 min d fatiguant 10 sec contraction 8 sec contraction 510 R activation 1 contractions toniques s quentielles Ce programme augmente la micro circulation l int rieur et autour des fibres musculaires trait es en cr ant des contractions rythmiques et en d veloppant une action de drainage Il peut tre appliqu galement des personnes d un certain ge pour am liorer la circulation IACER SRL MNPGO5 08 Ed 12 10 10 Pag 68 sanguine et lymphatique dans les membres inf rieurs par exemple en appliquant CH1 sur le mollet droit CH2 sur la cuisse droite CH3 sur le mollet gauche CH4 sur la cuisse gauche Ces programmes ex cutent dans les phases 2 et 3 des contractions toniques s quentielles sur les 4 canaux capables de reproduire l effet typique du drainage lymphatique l
129. tale programma 30 minuti Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 Ue nu cau ff ti Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 Fase 4 10 min Allenamento 10 min Allenamento 5 min Riscaldamento 20 sec recupero 20 sec recupero 5 min Defaticante 10 sec contrazione 10 sec contrazione 506 Forza base Il programma di Forza viene utilizzato in ambito sportivo per sviluppare la forza di base che per definizione la tensione massima che un muscolo pu esercitare contro una resistenza costante Nella fase di lavoro le contrazioni si alternano a periodi di recupero attivo IACER SRL MNPG05 08 Ed 12 10 10 Pag 12 IG E MEDICAL DIVISION permettendo di allenare il muscolo senza sottoporlo a stress migliorando l ossigenazione del muscolo stesso L indicazione base per ottenere i primi risultati la seguente due sedute a settimana per distretto muscolare per le prime tre settimane ad intensit crescente 20 30 tre sedute settimana per le successive tre settimane ad intensit elevata 30 50mA L aumento della intensit deve essere graduale ed eseguito trattamento dopo trattamento senza sovraffaticare i
130. tensity capable of causing discomfort The equation more pain more gain is completely misleading and counterproductive Great and significant results are obtained through consistency and patience E07 Relaxing massage Can be used for all sports after competitions or the most demanding training sessions in particular after long and intense exertion Program similar to the previous one however it uses lower frequencies with a greater capacity for vascularization To be used immediately after exertion Helps drainage and capillarization improving muscle oxygenation and helping to discharge synthetic substances produced during exertion Program duration 15 minutes Stimulation intensity medium low increased during the last 10 minutes Position of electrodes see photos 01 to 20 in the manual of positions IACER SRL 05 08 Ed 12 10 10 Pag 45 E08 General recovery Can be used for all sports after competitions or the most demanding training sessions in particular after long and intense exertion To be used immediately after exertion Helps drainage and capillarization improving muscle oxygenation and helping to discharge synthetic substances produced during exertion Program duration 15 minutes Stimulation intensity medium low increased during the last 10 minutes Position of electrodes see photos 01 to 20 in the manual of positions E09 Drain up These specific drainage programs increase microcirculation withi
131. to 09 Glutei foto 19 Ve AN oe ae ti Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 Fase 4 20 min Allenamento 20 min Allenamento 5 min Riscaldamento 20 sec recupero 22 sec recupero 5 min Defaticante 10 sec contrazione 8 sec contrazione 510 Contrazioni toniche sequenziali Questo programma aumenta la microcircolazione all interno e intorno alle fibre muscolari trattate creando delle contrazioni ritmiche favorendo cosi una azione drenante Pu essere applicato anche su persone non pi giovani per migliorare la circolazione sanguigna e linfatica negli arti inferiori es applicando CH1 su polpaccio destro CH2 su coscia destra CH3 su polpaccio sinistro CH4 su coscia sinistra programmi eseguono nella fase due e tre delle contrazioni toniche sequenziali sui 4 canali in grado di riprodurre l effetto tipico del drenaggio linfatico elettronico Questi programmi possono essere eseguiti con l utilizzo degli elettrodi adesivi L intensit di stimolazione deve essere sufficiente a garantire delle buone contrazioni muscolari durante il trattamento ma tali da non produrre indolenzimento 20 25mA Il lavoro prevalente sulle fibre lente Descrizione programma gruppi muscolari interessati con riferimento foto posizionamento elettrodi 10 Contrazioni toniche Durata totale programma 25 minuti Gruppi muscolari tutti quelli
132. to contract over this limit stimulation does not become more effective just more irritating so it is best to stop before that point The first benefits can be seen after 10 to 12 treatments carried out on a daily basis proceed with the treatment until the symptoms pass Position of electrodes photo 25 Eletcrodes Positioning cervical zone photo 25 Phase 1 Phase 2 Tens microimpulses 30 min Decontracting 3 min IACER SRL MNPGO5 08 Ed 12 10 10 Pag 48 MEDICAL DIVISION A07 Lumbal pain Medical program only on T ONE EVO II Specific program for the treatment of pain in the lumbar area The intensity should be adjusted to a level between the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin to contract over this limit stimulation does not become more effective just more irritating so it is best to stop before that point The first benefits can be seen after 15 to 20 treatments carried out on a daily basis proceed with the treatment until the symptoms pass Program duration 40 minutes Position of electrodes see photo 27 in the manual of positions Electrodes Positioning lumbar area photo 27 Phase 1 Phase 2 Tens microimpulses 30 min Tens Burst 5 min 08 Sciatalgy Medical program only on T ONE EVO II Specific program for the treatment of pain in the sciatic area The intensity should be adjusted
133. tretto 15 min Tens a impulso largo 20 min 13 Hematoma Medical program only on T ONE EVO II Consult a doctor before using this program to treat haematomas Total program duration 20 minutes Few applications carried out within a few hours of the bruise A combination of various types of square wave impulses has a graduated draining effect on the area to be treated impulses at different frequencies drain the area at different depths The intensity should be adjusted to a level between the thresholds of perception and pain without causing muscle contraction Position of electrodes form a square above the area to be treated as shown in illustration 1 14 Regenerating skin only on T ONE EVO II This program has four phases with three different impulses to vascularize and tone the superficial muscles It also produces a local pain relieving action The intensity should be adjusted to a level between the thresholds of perception and pain Electrodes Positioning form a square above the area to treat as shown in illustration 1 Phase 1 Phase 2 Phase 3 Phase 4 10 min 10 min 10 min 10 min Vascularization Tens micrompulses Tens sequential Vascularization A15 Atrophy prevention Medical program only on T ONE EVO II Program created to maintain muscle trophism This treatment concentrates on muscle toning paying particular attention to slow twitch fibres Particularly indicated for patients
134. uenza pi alta durante la contrazione Si tratta dunque di una contrazione sulle fibre rapide Questi programmi dunque in senso logico trovano applicazione dopo aver concluso il ciclo di tonificazione 20 30 sedute distribuite in un tempo di 45 60 giorni Proprio per la maggiore frequenza durante la fase di contrazione e la intensit pi alta nei primi giorni di applicazione possibile riscontrare un leggero indolenzimento dei muscoli trattati Intensit di stimolazione medio alta 20 35mA Descrizione programmi gruppi muscolari interessati con riferimento foto posizionamento elettrodi IACER SRL MNPG05 08 Ed 12 10 10 Pag 16 04 Definizione Durata totale programma 25 minuti Bicipite foto 02 15 Tricipite foto 03 16 Estensori della mano foto 04 Flessori della mano foto 05 Deltoide foto 06 Addominali foto 01 20 Gran pettorale seno foto 07 17 Trapezio foto 08 Gran dorsale foto 09 Glutei foto 19 Ve AN we ae fl d Quadricipiti cosce foto 11 18 Bicipiti femorali foto12 Polpacci foto13 Tibiale anteriore foto14 Fase 1 Fase 2 Fase 3 Fase 4 10 min Allenamento 5 min Allenamento 5 min Riscaldamento 13 sec recupero 14 sec recupero 5 min Defaticante 7 sec contrazione 6 sec contrazione E05 Modellamento Grazie alla combinazione di impulsi di capillarizzazione e tonificanti questo programma favorisce un azione di mobilizzazione dei grassi nelle zone di accumu
135. ufacturer For any assistance intervention contact the National Distributor or the manufacturer at the following address LACER S r l Via S Pertini 24 a 30030 Martellago VE Italy Tel 39 0415401356 Fax 39 0415402684 www iacer it iacer iacer it You can get any technical documentation on spare parts but only prior business authorization T ONE EVO II All rights reserved T ONE EVO II and logo are owned by IACER Srl and are registered IACER SRL 05 08 Ed 12 10 10 Pag 53 I TECH IACER SRL 05 08 Ed 12 10 10 Pag 54 Mode d emploi Mod les EVO I EVO Il ATTENTION ONE EST UN APPAREIL MEDICAL En cas de probleme de sant n utiliser ONE qu apr s avoir consult son m decin traitant des lectrodes avant d utiliser T ONE Avant d utiliser les programmes il Lire attentivement le mode d emploi et la notice concernant le placement m dicaux lire attentivement les contre indications et les instructions IACER S r l via Pertini 24 A 30030 Martellago Venezia Italie Tel 0039 041 5401356 Fax 0039 041 5402684 e mail iacer iacer it www itechmedicaldivision com IACER SRL 05 08 Ed 12 10 10 Pag 55 SOMMAIRE DU MODE D EMPLOI 1 Contenu du kit T ONE Pag 57 2 Emploi Contre indications Effets collat raux Pag 57 3 Avertissements Pag 57 4 Signification des symboles plac s sur T ONE et dans le manuel Pag 59 5 Guide d utilisation de
136. uffement 4 Appuyer sur les touches g 9 pour indiquer si l utilisateur est un homme ou une femme IACER SRL MNPGO5 08 Ed 12 10 10 Pag 60 S lection femme S lection homme 5 S lectionner ensuite le groupe musculaire concern en appuyant sur les touches 7 ME UN buste membres buste membres inf rieurs homme sup rieurs femme femme femme membres inf rieurs homme membres sup rieurs homme 6 Pour entamer le travail de stimulation appuyer sur la touche le texte suivant apparait sur l cran positionner les lectrodes sur la peau brancher les c bles et augmenter l intensit au moment d appuyer sur la touche s assurer que l on a bien Suivi les INSTRUCTIONS PRELIMINAIRES pour commencer la s ance de travail appuyer sur la touche A des canaux utilis s pour l lectrostimulation et augmenter l intensit du courant de sortie T ONE se placera automatiquement sur la page cran de travail en visualisant le nom du programme choisi 7 R gler l intensit de stimulation en appuyant sur la touche des canaux concern s jusqu atteindre le niveau de tol rance personnel stimulation confortable Programme Nombre de phases Dur e totale du programme Indicateur de niveau s lectionn phase en cours compte rebours ES la phase en cours gt des piles rated d U programme 518 FENETRE Barre d indication en COUTS 15 66 des contrations et d application fa R sista nce de r cup rati
137. uide d utilisation de T ONE Description des commandes Mise en marche et A Ecran LCD ek d aoe avec affichage de la s lectioit S lection des programmes Allumage d groupes musculaires S lection des domaines d application homme femme et saut de phase domaines d application ex homme et femme Augmente l intensit du canal Diminue l intensit du canal Sortie canal 1 Sortie canal 4 cable bleu um c ble blanc Sortie canal 2 i Sortie canal 3 cable jaune c ble rouge Instructions pr liminaires Avant de proc der l utilisation de T ONE nettoyer la peau pr s de la zone traiter relier les c bles d lectrostimulation l lectrode avec le c ble d connect de T ONE positionner les lectrodes autocollantes sur la peau voir photo dans la notice concernant le placement des lectrodes brancher les c bles de transmission des impulsions dans les fiches pr vues cet effet et allumer l appareil Attention avant de d brancher les lectrodes s assurer que l intensit des canaux est z ro et que T ONE est teint Mode op ratoire lire tout le mode d emploi avant de se servir de l appareil 1 Allumer T ONE en appuyant sur le bouton pendant au moins une seconde 2 S lectionner le champ d application Sport Beauty Tens avec les touches g 3 Proc der au choix du programme souhait avec les touches GD LD exemple S01 Echa
138. uipment not protected Housing ABS Power Supply Ni Mh rechargeable battery 4 8V 1600mAh Battery charger model XKD C0300NHS6 0 5W input 100 240 VAC 50 60Hz output 6 VDC 300mA Ave consumption 1 W Limitations equipment not suitable for use in environments with a high concentration of oxygen and or flammable liquids and or flammable gas do not use with equipment for electrosurgery or short wave or microwave therapy Operation equipment suitable for continuous operation Output channel 4 channels independent and galvanically isolated Output current maximum power peak to peak 218mA 31 mA max effective per single channel with load from 200 ohm to 1000Kohm Type of impulse compensated biphasic square wave IACER SRL MNPGO5 08 Ed 12 10 10 Pag 52 IR MEDICAL DIVISION Frequency operates with a range of impulses from 1 Hz to 150 Hz Impulse amplitude from 40us to 800us sum of the two semi impulses Display reflective LCD display Control keypad 7 key keypad in ABS Dimensions 125X76X34 mm Weight 280 gr including batteries Maintenance and storage refer to the instructions in Chapter 8 Maintenance and storage of T ONE Warning the equipment delivers current in excess of 10mA C 0476 Produced in compliance with the 93 42 directive concerning medical devices and following modifications Dir 2007 47 18 Assistance Every intervention on device must be performed by man
139. unte per cercare di migliorare il livello di stimolazione e di conseguenza le prestazioni Impulso di massaggio defaticante recupero attivo l intensit dovr essere regolata gradualmente ottenendo un massaggio del muscolo trattato Si consiglia di regolare l intensit a valori tali da ottenere un massaggio assolutamente confortevole Si tenga conto che in questo caso non bisogna resistere ad intensit elevate perch si tratta di un massaggio pertanto sar possibile progredire gradualmente con l aumento dell intensit senza eccessi Impulso di capillarizzazione alzare gradualmente l intensit fino a produrre una stimolazione costante e visibile dell area trattata si consiglia una soglia di stimolazione media sempre al di sotto della soglia del dolore Impulso di lipolisi drenaggio l effetto pompa viene prodotto da contrazioni toniche sequenziali Ora l intensit deve essere sufficiente a produrre queste contrazioni maggiore sar la contrazione maggiore sar l effetto pompa indotto Ma attenzione non serve resistere ad intensit elevate tali da produrre dolore Si consiglia di eseguire le prime sedute di elettrostimolazione ad intensit basse in modo da consentire all organismo di adattarsi a sensazioni nuove In questo modo l aumento di intensit sar graduale e per nulla traumatico Impulso tens nei programmi tens l intensit va regolata tra la soglia di percezione e la soglia di fastidio Il limite massimo rap
140. usive de Srl et est enregistr IACER SRL MNPGO5 08 Ed 12 10 10 Pag 80 I TECH IACER SRL 05 08 Ed 12 10 10 Pag 81 S r l SU Sede operativa 30030 Martellago VE Via S Pertini 24 A Tel 39 041 5401356 Fax 39 041 5402684 Sede legale S Marco 2757 30124 Venezia Cod Fisc P VA 00185480274 R EA VEN 120250 M VE001767 Cap Soc 110 000 00 i v www iacer ve it iacer iacer it
141. vel of intensity increasing it gradually For practised athletes the intensity used should be enough to produce visible muscle contractions In the event of muscle ache stimulation use the 502 program recovery S05 Long effort SIS S Total duration 30 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 photo14 ti Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial Phase 1 5 min warm up Phase 2 10 min 20 sec recovery 10 sec contraction Phase 3 10 min 20 sec recovery 10 sec contraction Phase 4 5 min recovery 506 Basic strength The Basic strength program is used in sport to develop basic strength which for definition is the maximum tension that a muscle can exert against constant resistance The contractions alternate with periods of active recovery during the work phase allowing the muscle to be trained without subjecting it to stress and improving oxygenation of the same muscle The following basic procedure will enable you to obtain the first results two sessions per week for each muscle region for the first three weeks at medium low intensity 20 30mA three sessions per week for the next t
142. ximately 15 20 less than the intensity of the contraction During the recovery phase the last phase the intensity should be adjusted to produce a good massaging effect of the stimulated area without producing any pain 18 30 mA 501 Warming up all muscle groups Program suitable for use before training sessions or competitions very useful for sports involving maximum effort right from the start Program duration 28 minutes Position of electrodes from photo 1 to photo 20 Recommended stimulation intensity medium 20 30mA the muscle must work without strain IACER SRL 05 08 Ed 12 10 10 Pag 38 MEDICAL DIVISION S01 Warming up Total duration 28 minutes Biceps photo 02 15 Triceps photo 03 16 hand extensors photo 04 hand flexors photo 05 Deltoid photo 06 Abdominals photo 01 20 Pectoral Breast photo 07 17 Trapezius photo 08 Large dorsal photo 09 Gluteus photo 19 HI LE Quadriceps Thighs photo 11 18 Biceps femoris photo12 Calves photo13 Anterior Tibial photo14 Phase 1 Phase 2 Phase 3 20 min 20 sec recovery 10 sec contraction 5 min Warm up with medium 3 min Warm up with low frequency frequency 502 Recovery Can be used for all sports after competitions or the most demanding training sessions in particular after long and intense exertion To be used immediately after exertion Helps drainage and winding down improving muscle
143. ysiologiques normales Ne pas placer les lectrodes pr s des zones sujettes des inflammations On conseille de faire une application par jour le nombre d applications n tant pas d fini ce programme peut tre utilis jusqu ce que la douleur diminue L intensit de stimulation conseill e doit se situer entre le seuil de sensibilit et le seuil de l g re g ne Dur e du programme 20 minutes en une seule phase Placement des lectrodes cf guide du placement des lectrodes de la photo n 25 la photo n 33 A12 D contractant seulement T ONE EVO II Programme indiqu pour acc l rer le processus de r cup ration de la fonction du muscle Il exerce une action imm diate Intensit r gl e peine au dessus du seuil de sensibilit On conseille deux applications par jour pendant 3 ou 4 jours IACER SRL MNPGO5 08 Ed 12 10 10 Pag 76 12 D contracturant Temps total du programme 35 minutes Placement des lectrodes en forme de carr sur la zone douloureuse conform ment au sch ma 1 Phase 1 Phase 2 Tens impulsion br ve 15 minutes Tens impulsion large 20 minutes 13 H matomes programme m dicaux seulement T ONE EVO II Consulter un m decin avant d appliquer ce programme sur les h matomes Dur e totale du programme 20 minutes en une seule phase Peu d applications sont n cessaires si l on intervient peu de temps apr s la contusion En combinant diff rents types d impu

Download Pdf Manuals