Home
        SDS© Drive - LIFT COMPONENTS
         Contents
1.                                 o   c   s  o    808 000 000 505   rel 3    Edition 18 December 2009    7    10    11  12  13    6 16  6 17    6 18    6 19    TRIAL OPERATIONS BEFORE SETTING AT WORK pag     7 1    7 2 Self learning cycle with the door controller only  without using the handset   INSTRUCTIONS WITH THE HANDSET pag   8 1 Handset  optional   8 2 User Handset menus and submenus  8 3 Self learning cycle activation by means of the handset  8 4 Reversing System Force setting by means of the handset  8 5 Setting reversing system offset with the keypad  8 6 Speed Profile and High Speed adjustments by means of the Handset  8 6 1 Option  Fast settings   8 7 Option    Set Factory Default     8 8 Option    Reserved Area     8 9 Option    Advanced Settings     8 9 1 Option    Opening Parameters     8 9 2 Option    Closing Parameters     8 9 3 Option    Reversing System Space     8 9 4 Option    Serial Bus     8 9 5 Option    Change Password     8 9 6 Option    Save set data     8 9 7 Option    Recall set data     8 9 8 Option    Data Download   8 9 9 Option    Data Upload     8 9 10 Option    Smooth reopening     GENERAL OPTIONS pag   9 1 Reversing System Setting by means of the Handset  9 2 Kn input Activation by means of the Handset  9 3 Activation of the Main Lift Controller Test by means of the Handset  9 4 Activation of the Main Lift Failure by means of the Handset  9 5 Main Lift Controller Alarm    MLC Input Alarm   9 6 Activation of the Car Door Locking Device setting
2.                            LIFT DOORS       SEMATIC All rights reserved   Changes can be made without notice        808 000 000 508 rel 3    Edition 18 December 2009  4 INSTALLAZIONE E COLLEGAMENTI DA EFFETTUARE    4 1 Connessioni Sematic Drive System   DC PWM    AC VVVF Brushless     505   DC PWM  sematic    ELEVATOR PRODUCTS      FOR FURTHER INFORMATION REFER TO THE USER S GUIDE    FUR WEITERE INFORMATIONEN BENUTZEN SIE BITTE DAS HANDBUCH    PER MAGGIORI INFORMAZIONI RIFERIRSI AL MANUALE UTENTE                   PROTECTION           KEEP CLOSED   GESCHLOSSEN HALTEN   MANTENERE CHIUSO            I OPENING LIMIT CLOSING LIMIT  DETECTOR  TURE AUF ENDKONTAKT TURE ZU ENDKONTAKT  PHOTOCELL LIMITE APERTURA LIMITE CHIUSURA         OPTIONAL     I  I                 I  I    DOOR OPENING RELAY  OFFNUNGS RELAIS  RELE  DI APERTURA    DOUBLE TB RELAY  DOPPELTE TB RELAIS  RELE  DI DOPPIO TB    DOOR CLOSING RELAY  SCHLIESS RELAIS  RELE  DI CHIUSURA    AUXILIARY RELAY  ZUSATS RELAIS  RELE  AUSILIARIO    FIREFIGHTING RELAY  FEUERWEHR RELAIS  RELE  DI FIREFIGHTING         E O D  ACTIVATION RELAY  E O D  AKTIVIERUNG RELAIS  ENCODER RELE  DI ATTIVAZIONE E O D     DOOR CLOSING RELAY IN SLOW SPEED    5 SCHLIESS RELAIS NIEDRIGE GESCHWINDIGKEIT     RELE  DI CHIUSURA IN BASSA VELOCITA  8  PHOTOCELL FUSE  2 250V 8A    Battery cyl 5x20  USE I 94      250V 4A I    REVERSE MOTION RELAY  cyl 5x20 IM  I  OPTIONAL   REVERSIERUNGS RELAIS        m TU kaa RELE  DI INVERSIONE DI MOTO 4    b  SELF LEARNING CYCL
3.                        Segnale Morsetti Tipo e stato del contatto Note  Contatto limite apertura La morsetti Questi collegamenti mettono         contatto    aperto quando l operatore    al  16   17 disposizione un contatto senza   limite apertura  tensione  Portata nominale  3A 250Vac 30Vdc  Contatto limite chiusura Lc morsetti Questi collegamenti mettono a  i  contatto    aperto quando l operatore    al  18   19 disposizione un contatto senza   limite chiusura  tensione Portata nominale  3A 250Vac 30Vdc  Segnale inversione di moto IM Questi collegamenti mettono a Questo segnale realizzato con contatto senza  disposizione contatti senza tensio    tensione  rel   interno al controller  viene  ne  attivato dal controller in caso di rilevamento di  un ostacolo meccanico  sforzo eccessivo  o su  morsetti  contatto normalmente chiuso  segnalazione di dispositivo esterno collegato al  1 4 controller stesso   Esso informa il quadro di manovra della neces   sit   di interrompere la chiusura e comandare  morsetti  contatto normalmente aperto  una apertura   2 4 Portata nominale  3A 250Vac 30Vdc  Segnale Ausiliario AUX Questi collegamenti mettono a Questo contatto pu   essere utilizzato per  disposizione contatti senza tensio    segnalare il raggiungimento di una particolare  ne quota di spazio  programmabile  o come Gong  in apertura o come segnalazione di un allarme  morsetti  contatto normalmente chiuso  termico   35   34 Portata nominale  3A 250Vac 30Vdc  morsetti  contatto normalm
4.                SEGNALI IN ENTRATA AL CONTROLLER  Segnale Morsetti Tipo e stato del contatto Note  Comando d apertura Ka morsetti Per questi collegamenti sono   Quando il controller    montato su una cabina  5   15 necessari contatti senza tensione    a doppio ingresso     importante che i comandi   proveniente dal Quadro di Manovra   contatto normalmente aperto  d apertura e chiusura non abbiano contatti in  comune tra le due porte   Comando di chiusura Kc morsetti Per questi collegamenti sono  3 15 necessari contatti senza tensione    Cavi protetti  messa a terra sono altamente   proveniente dal Quadro di Manovra   contatto normalmente aperto  raccomandati  Comando chiusura forzata morsetti Per questi collegamenti sono   La chiusura forzata pu   essere comandata dal  a bassa velocit   Kb 15 22 necessari contatti senza tensione    quadro di manovra  nel caso in cui fosse pre    contatto normalmente aperto  vista la messa fuori servizio della fotocellula  o  dispositivo analogo   o dopo diversi tentativi di  chiusura senza risultato   Comando di riapertura Kn morsetti Per questi collegamenti sono   Per il collegamento al controller vedere i para   15 23 necessari contatti senza tensione    grafi 4 1 1 e 4 1 2   stato attivo selezionabile   Contatto Fire Fighting Kff morsetti Per questi collegamenti sono   Vedere il capitolo 6 9  15   39 necessari contatti senza tensione    contatto normalmente aperto   Contatto K2TB morsetti Per questi collegamenti sono   Questo segnale permet
5.             5 1 Modalit   automatica    AUTO      e Quando il controller sta funzionando in modalit   automatica il led rosso    AUTO       acceso mentre gli altri due led rossi  sono spenti    Quando il controller viene acceso o in seguito ad un autoreset il controller entra nel modo di funzionamento auto   matico        Drive    e I segnali provenienti dal quadro di manovra e dai dispositivi esterni  barriere  fotocellule ecc     sono attivi    e I tasti 2 e 3  di apertura e chiusura rispettivamente  non sono attivi e quindi non eseguono alcuna funzione    e Con il tasto 1    possibile fare eseguire al sistema un ciclo di autoapprendimento    e Se si preme per qualche istante  circa 3 sec   il tasto 4 si passa in modalit   manuale                 5 2 Modalit   manuale    MAN      e Quando il controller sta funzionando in modalit   manuale il led rosso    MAN       acceso mentre gli altri due led rossi  sono spenti    e I segnali provenienti dal quadro di manovra e dai dispositivi esterni sono ignorati    e Il contatto IM    disattivato  quindi il controller non rileva segnali da dispositivi esterni per l inversione di moto quali  barriere o fotocellule    e L apertura e la chiusura sono comandate manualmente tramite i tasti 2  apertura  e 3  chiusura     e Con il tasto 1 posso fare eseguire al sistema un autoapprendimento    e Se si preme per qualche istante  circa 3 sec   il tasto 4 si passa in modalit   automatica    AUTO       e Se nessun tasto viene premuto per 10 minut
6.             ALARMS TABLE  Code on Viewed error Error description Action undertaken by Door Controller  display   01 No MLC Signal Main lift controller is disconnected or has failed  Note 1    Auto reset when proper condition is resto    red    02 Over current protec    Motor over current due to door mechanical strain  Note   Auto reset after ca 10 seconds  depending   tion 2  on motor     03 Reversing System   The main lift controller does not send the reopening com    Door drive keeps on closing at low speed    fault mand after the Door Controller has signalled an obstacle   Note 3   04 Power on motor inver    Inverted motor connection or inverted Encoder channels    Auto reset  after about 10 seconds  when  ted Door performs a jerk and then stops  Note 4  normal operating conditions are restored   after 5 trials the system stops    05 Encoder jerk Interruption of the motor s Encoder cables  or interrup    Auto reset after 5 seconds  after 5 occur   tion of the motor cables after system s start up or the   rences within 5 minutes the system stops  connecting plug to the Encoder motor is inverted   06 Motor thermal protec    Motor over heating  with motors where internal PTC sen    Auto reset when normal operating condi    tion sor is present  tions are restored    07 Motor jerk Interruption of the motor cables Auto reset after 5 seconds  after 5 occur    rences within 5 minutes the system stops   08 Over voltage Over voltage in the power supply Door controller switches to lo
7.           LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009  8 2 Men   e sottomen   tastierino a disposizione          IMPOSTAZIONE OPZIONI AUTO  AGGIORNAMENTI  PROFILI GENERALI MANUTENZIONE APPRENDIMENTO SOFTWARE    Y Y Y    Scelta modalit   I M                                                        Impostazioni rapide cod  00 Monitor  Alta velocit   apertura Test Quad Manov                 10 cod  01 Statistiche          Y Y       Bassa velocit   apertura                                           cod  11 Mancanza Quad Manov  WT            02 Ultimi allarmi  Comfort apertura Y Y  cod  12 Allarme Quad Manov  Contatori  cod  03 allarmi  Alta velocit   chiusura  cod  13 Y Y  Ingresso Kn z  Monitor Quad Manov   Bassa velocit   chiusura cod  04  cod  14 Y Y               Gancio di cabina  Comfort chiusura cod  05    cod  15    Y Y    Porte in vetro e pesanti       Dati di Garanzia                                                                                                          Inversione di moto cod  06  Forza di inversione di moto    cod  09 o  Offset di inversione di Y  moto Opzioni Fire Fighting   Y cod  19   Impostazioni avanzate Y  Timeout EOD   cod  20   Parametri apertura Y       Logica ingresso Kn  cod  21    Y    Rotazione in chiusura       Parametri chiusura                            Spazio inversione cod  22  Opzioni bus Seriale Motore                Modifica Password        Tipo staz  chiusura                      cod  25  Salva Profilo Y  Tipo
8.        KEEP CLOSED   GESCHLOSSEN HALTEN   MANTENERE CHIUSO            I OPENING LIMIT CLOSING LIMIT  DETECTOR  TURE AUF ENDKONTAKT TURE ZU ENDKONTAKT  PHOTOCELL LIMITE APERTURA LIMITE CHIUSURA         OPTIONAL     I  I                 I  I    DOOR OPENING RELAY  OFFNUNGS RELAIS  RELE  DI APERTURA    DOUBLE TB RELAY  DOPPELTE TB RELAIS  RELE  DI DOPPIO TB    DOOR CLOSING RELAY  SCHLIESS RELAIS  RELE  DI CHIUSURA    AUXILIARY RELAY  ZUSATS RELAIS  RELE  AUSILIARIO    FIREFIGHTING RELAY  FEUERWEHR RELAIS  RELE  DI FIREFIGHTING         E O D  ACTIVATION RELAY  E O D  AKTIVIERUNG RELAIS  ENCODER RELE  DI ATTIVAZIONE E O D     DOOR CLOSING RELAY IN SLOW SPEED    5 SCHLIESS RELAIS NIEDRIGE GESCHWINDIGKEIT     RELE  DI CHIUSURA IN BASSA VELOCITA  8  PHOTOCELL FUSE  2 250V 8A    Battery cyl 5x20  USE I 94      250V 4A I    REVERSE MOTION RELAY  cyl 5x20 IM  I  OPTIONAL   REVERSIERUNGS RELAIS        m TU kaa RELE  DI INVERSIONE DI MOTO 4    b  SELF LEARNING CYCLE BUTTON   PUSH AT INSTALLATION   TASTE F  R SELBSTLERNZYKLUS   BEI INSTALLATION DR  CKEN   TASTO PER CICLO DI AUTOAPPRENDIMENTO   PREMERE ALLA INSTALLAZIONE     110V 230V  LEAD FREE L  RoHS Compliant    0          Directive 2002 95 EC  COD  H147AASXO1 1          4 2 Sematic Drive System   AC VVVF Brushless Plus  connections    SDS   AC VVVF Brushless Plus            FOR FURTHER INFORMATION REFER TO THE USER S GUIDE      F  R WEITERE INFORMATIONEN BEN  TZEN SIE BITTE DAS HANDBUCH        PER MAGGIORI INFORMAZIONI RIFERIRSI AL MAN
9.      4 Se entrambi i collegamenti  motore e segnali di retroazione  risultano invertiti la porta apre su segnale di chiusura e chiude su segnale di  apertura  L operatore    cablato e collaudato in fabbrica  occorre prestare particolare attenzione nel caso di sostituzione del motore e o dei  cablaggi        SEMATIC    All rights reserved     E   2  2  5  3  5         8  8      E         5  8      8  2  8  o    22    LIFT DOORS    808 000 000 505  rel 3     Edition 18 December 2009  7 OPERAZIONI PRELIMINARI ALLA MESSA IN FUNZIONE    Per evitare danneggiamenti  prima di accendere il controller verificare che la tensione di alimentazione sia contenuta  entro i valori previsti     Prima di mettere in funzione l impianto occorre effettuare un ciclo di autoapprendimento e impostare i parametri secon   do le opzioni generali  descritte nel 8 6  che caratterizzano l installazione     7 1 Ciclo di Autoapprendimento   Il ciclo di autoapprendimento consente al controller di memorizzare la corsa  tra il limite di chiusura e il limite di aper   tura   Detto ciclo pu   essere attivato solo manualmente e deve essere effettuato sotto la diretta supervisione del manu   tentore affinch   verifichi che avvenga correttamente  cio   che il controller memorizzi dei dati corretti   Il ciclo di autoap   prendimento    indicato dalla visualizzazione  SL  sul display presente sul controller     Importante    e Durante l autoapprendimento porre attenzione che i pannelli delle porte scorrano liberamente
10.     TENSIONE DI ALIMENTAZIONE 230 400           10   50 60 Hz  TENSIONE DI ALIMENTAZIONE CONTROLLER 36 Vac 10   50 60 Hz  POTENZA INSTALLATA 500 VA o 750 VA  POTENZA DI PICCO 1000 VA  per trasformatore 500 VA   1400 VA  per trasformatore 750 VA   PROTEZIONE SOVRACORRENTE MOTORE      15 minuti   2I    3 minuti  GAMMA DI TEMPERATURE da  10  C a  60  C  GRADO DI UMIDIT   non condensante tra 20  e 80   PROTEZIONE fusibile interno alimentazione a lama  30 A   fusibile interno batteria a lama  30 A   VELOCIT   DI FUNZIONAMENTO regolabile separatamente per apertura e chiusura  SENSIBILIT   DI INVERSIONE DI MOTO variabile  inserita nella sola fase di chiusura dei pannelli    3 4 Door Controller Sematic Drive System  Brushless Plus  AC VVVF Brushless Plus     CAR DOOR  OPERATOR  CONTROLI  Brushless PLUS    n              n     a  79              181817462241 Ta       Pulsante accensione   Pulsante spegnimento   Display   Pulsanti per modalit   manuale   Porta per connessione RJ45  Tastierino    Connessioni motore e alimentazione EOD dirette con morsetti a vite   Porta per connessione RJ45  Encoder Motore    Morsetto a 4 poli per connessione barriere detector  cod  EQ66AARX 06   Morsetto a 6 poli per connessione segnali Quadro di Manovra  cod  E066AARX 03   10 Morsetto a 6 poli per connessione segnali Quadro di Manovra  cod  E066AARX 04   11 Morsetto a 10 poli per connessione segnali Quadro di Manovra  cod  E066AARX 07   12 Ingresso alimentazione 36 Vac   Gnd con morsetti a vite       
11.    E molto importante che l installatore sia comunque presente durante il secondo autoapprendimento automatico  per verificare che esso venga eseguito correttamente    LIFT DOORS                         SEMATIC    All rights reserved   Changes can be made without notice     19             SEMATIC    All rights reserved                 2  5  3             8  S  E      E         8      8      s  o    20    808 000 000 505   rel 3    Edition 18 December 2009   6 11 Utilizzo E O D   Emergency Opening Device  e tempo di disattivazione  Codice Param  20    In particolari situazioni di emergenza  quali ad esempio la mancanza di alimentazione di rete potrebbe essere comodo  ed auspicabile fare in modo che  una volta raggiunta la zona di accoppiamento porta di cabina porta di piano  le stes   se si aprano  rimangano aperte per un tempo determinato e si richiudano con profili di apertura chiusura e velocit    pressoch   normali  A fronte di questa esigenza Sematic offre come optional ai suoi Clienti il dispositivo Sematic E O D    Emergency Opening Device    Quando il controller Sematic Drive System     alimentato da batterie  optional  e la cabina si trova al piano di emergen   za designato  l ingresso KEOD abilita il segnale di apertura delle porte  Dopo un tempo di disattivazione impostato    vedi  parametro 20 tempo di disattivazione E O D    il controller chiude le porte  in modo da preservare la durata nel tempo  delle batterie     Un interruttore magnetico  optional   montato su
12.    ENG ITA       SDS  Drive      e        5 2      Drive   Instruction Manual  Motorizzazione   Manuale    808 000 000 E 18 December 2009        A DC PWM  A AC VVVF BRUSHLESS  A AC VVVF BRUSHLESS PLUS             L IF T D O O R S    808 000 000 505   rel 3    Edition 18 December 2009  Confidentiality agreement Disclaimer    The software hardware    Sematic Drive System   and all the relevant information  ideas  concepts and know how         confidential and the exclusive property of Sematic         information relevant to this instruction manual and any other support supplied by Sematic must be kept confiden   tial and proprietary to Sematic and shall not to be copied or reproduced in any form whatsoever    Any information contained in the    Sematic Drive System      shall not be disclosed to anyone  without Sematic s written  consent apart from authorized representatives employed by the user which commits itself to the confidentiality clause   The Company that makes use of the Sematic Drive System   binds itself not to use confidential informations owned by  Sematic and not to compile or reingineer the Sematic Drive System  and any information in it contained     Clausola di riservatezza    Il sistema software hardware  Sematic Drive System   e le informazioni ivi contenute  le idee  i concetti e il know how   sono confidenziali e di propriet   della Sematic    Le informazioni contenute in questo manuale ed ogni altro supporto fornito dalla Sematic devono essere mantenuti c
13.   Attenzione  l impostazione di default Sematic       sensibilit   inversione di moto ridotta     parametro 19 1   La modi   fica di questo parametro    a discrezione dell utente  a seconda di accurate considerazioni e della normativa vigen   te nel paese in cui l impianto    installato     Al termine del primo ciclo di chiusura  il quadro di manovra puo riportare la cabina al piano di accesso dei Vigili del  Fuoco  se gi   non vi si trova    Il controller Sematic Drive System   agisce solo in dipendenza dei segnali provenienti dal quadro di manovra  Anche  durante la fase di apertura    possibile invertire il movimento rimuovendo il segnale Ka e attivando il segnale Kc     Il Quadro di Manovra deve costantemente rilevare la pressione continua dei pulsanti in cabina  porta aperta e chiama   ta al piano   effettuata dal Vigile del Fuoco che controlla l impianto    Durante un ciclo di chiusura  il rilascio del pulsante di chiamata al piano deve determinare il rilascio del segnale Kc e  l inserimento del segnale Ka  oltre alla cancellazione della chiamata    Durante un ciclo di apertura  il rilascio del pulsante di apertura porta deve determinare il rilascio del segnale Ka e l in   serimento del segnale Kc    AI termine della corsa di chiusura o di apertura  rilevabile tramite  rispettivamente  i segnali Lc e La  il quadro di manovra  pu   rilevare il rilascio del pulsante di chiamata al piano o di apri porta senza inserire il segnale Ka e Kc rispettivamente  il  controller atte
14.   e    MENU     premendo il tasto      si ritorna al MENU PRINCIPALE    Se l opzione scelta    CONTATORI ALLARMI il display visualizzer   l elenco degli allarmi indicandone il codice  la descri   zione e il numero di volte che sono occorsi    Con i tasti    e W scorrere l elenco degli allarmi memorizzati    Sono disponibili le opzioni    e  BACK   premendo il tasto F1 si ritorna al men   MANUTENZIONE   e  CANC   premendo il tasto F2 si cancellano gli allarmi memorizzati   e    MENU     premendo il tasto      si ritorna al MENU PRINCIPALE    Gli allarmi visualizzabili sono quelli previsti nella tabella al 8 6 16    Se l opzione scelta    MONITOR QUADRO DI MANOVRA il sistema torna a seguire i segnali del quadro di manovra  il  display visualizzer   una lista completa degli ingressi e delle uscite con il loro valore    Nel momento in cui il segnale dell ingresso o dell uscita    attivato la sigla sul display cambier   grafica in carat    tere chiaro su sfondo scuro    Sono disponibili le opzioni    e  BACK   premendo il tasto F1 si ritorna al men   MANUTENZIONE   e  MENU   premendo il tasto      si ritorna al men   PRINCIPALE    Se l opzione scelta    DATI DI GARANZIA verranno visualizzate    e     data di scadenza della garanzia    e le ore di attivit   residue prima della scadenza della garanzia    e la versione firmware attualmente in uso    e il tipo di motore utilizzato    Sono disponibili le opzioni    e  BACK   premendo il tasto F1 si ritorna al men   MANUTENZIONE  e  MEN
15.   increased using the keys    and   respectively           LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    8 6 Speed Profile and High Speed adjustments by means of the Handset   Connect the handset to RJ45 connector   If necessary  using keys    and   choose the required language and confirm with the  OK  key  Using keys    and    run through the  main menu    and choose  Profile settings     Press the    OK    key to confirm the option   On the display the following options are viewed     Fast setting  Reversing system  Advanced Settings  Set Factory Default  Reserved Area    Using keys    and    run through the menu  Profile setting    and choose the required option  Using the  OK  key  confirm the option  The following options are available      BACK   press key F1 to restore the  Main Menu       MENU   press key F3 to restore the  Main Menu      8 6 1 Option  Fast settings    This option allows to easily and quickly modify the speed profiles  Choose this option as indicated in the first   part of Paragraph 8 5   The following options are viewed on the display    e OPENING PARAMETERS    e    diagram shows the examined cycle speed profile  opening or closing          the upper left side a number is given which indicates the currently used speed percentage  Using keys             on the handset to modify it    e On      lower left side a number is given which indicates the currently used speed m s    On the lower left side a number is given which indicat
16.   le persone addette all installazione e o manutenzione devono conoscere il prodotto Sematic e devono essere state  addestrate presso la Sematic o presso un rivenditore autorizzato Sematic    le attrezzature di montaggio utilizzate devono essere in stato di efficienza e gli strumenti di misura mantenuti sotto  controllo  89 655 CEE      Sematic    si impegna a tenere aggiornato il presente manuale e ad inviare al Cliente copia dei nuovi aggiornamenti con il  materiale    attraverso la propria politica di miglioramento del prodotto  si riserva il diritto di modificare disegni e materiale dello  stesso  Sematic dar   un tempo ragionevolmente sufficiente a tutti i propri clienti per poter adattare i loro prodotti  complementari    garantisce il buon funzionamento unicamente per i prodotti originali venduti direttamente e correttamente  installati     Pertanto    parti costruite e o aggiunte al prodotto Sematic senza il suo diretto controllo  o parti costruite su disegno Sematic   anche se fornite da rivenditori autorizzati  ma non originali  non potranno essere garantite non essendo assicurati i  seguenti aspetti essenziali     1  2  3  4    La    La                                             e            Controllo      accettazione della materia prima  Controllo di processo   Controllo di prodotto   Collaudi di conformit   a specifiche Sematic    Sematic  inoltre    garantisce la durata nel tempo dei propri prodotti solo se correttamente immagazzinati  stoccati sottotetto ad u
17.   main menu  and choose  Maintenance   e Press  OK  to confirm the choice  e The following options are viewed on the display   e MONITOR  STATISTICS  LAST ALARMS  ALARMS COUNTERS  MLC MONITOR  MAIN LIFT CONTROLLER MONITOR   WARRANTY  e The following options are available      BACK   Press key F1 to restore the menu MAINTENANCE  e  MENU   Press key      to restore the MAIN MENU    e Using keys    and V  run through the MAINTENANCE menu and choose the required option  e Press  OK  to confirm the choice    If the option MONITOR is chosen  the display shows opening and closing speed profiles  with a indication of the speed   in m s    The following options are available    e  Loop   Pressing key F1 the door performs a number of consecutive opening and closing cycles until key F1 is pres   sed again  Before movement it is possible to set the pause gap between an opening and closing cycle   Confirm with  OK  key           lt  gt     or     gt  lt      Press key F2 to let the doors respectively open or close   e  MENU   Press key F3 to restore the MAIN MENU    If the option STATISTICS is chosen   the display shows the door total working time expressed in days hours minutes   the cycle total number which have been performed in this working time and the manufacture date    The following options are available        BACK   Press key F1 to restore the menu MAINTENANCE   e  MENU   Press key      to restore the MAIN MENU    If the option LAST ALARMS is chosen the display shows the last oc
18.   presente un trasformatore da  500 VA    750 VA 230 400 Vac   10   primario     36 Vac   10    secondario     L apparecchiatura gestisce l apertura e la chiusura di porte per ascensore       modo completamente automatico controllando i tempi  le correnti  le velo   cit    alta  bassa  rampe di accelerazione e decelerazione   i diversi sistemi  di sicurezza  inversione di moto  riapertura parziale       e le anomalie di fun   zionamento  sovratensioni  connessioni interrotte           Per il ciclo di apertura ed il ciclo di chiusura sono gestiti due profili di curva  indipendenti uno dall altro  5  con possibilit   di modifiche tramite i pulsanti  posti nel controller o tramite tastierino  accessorio con visore e tastiera a 8  tasti collegabile alla scheda tramite connettore RJ45      Il tastierino  6     un terminale che permette di visualizzare e variare i para   metri di funzionamento memorizzati nel controller    E molto importante possedere il tastierino durante l installazione o la manu   tenzione dell impianto perch   tramite esso    possibile impostare  variare o  semplicemente visualizzare le scelte  i parametri  le impostazioni del con   troller e visualizzare gli errori occorsi durante il funzionamento     Inoltre vi    la possibilit   di utilizzare il tastierino direttamente dall interno  della cabina  7    In questo modo ci si trover   ad operare in situazione di assoluta sicurezza e  si potr   controllare il movimento delle porte accoppiate in situazione reale d
19.  01   gt  On  funzione abilitata     6 4 Ingresso Kn  Codice Param  04    Questo ingresso permette la scelta di 3 possibili opzioni di utilizzo per la funzione KN   6 4 1  Tipo Default   Barriere fotoelettriche e dispositivi a raggi infrarossi sono collegati direttamente al controllerin caso di presen   za di un ostacolo la porta riapre completamente  Il segnale di inversione di moto IM viene inviato dal control   ler al monitor del quadro di manovra esterno fino a quando le porte non sono completamente aperte     6 4 2  Apertura parziale    La riapertura parziale permette la riapertura delle porte in presenza di un ostacolo  rilevato da barriere optoe   lettroniche tradizionali o in prossimit   dei pannelli  Le porte riaprono solo per il tempo durante il quale l ostaco   lo    presente e non necessariamente fino al limite di apertura  Il segnale di inversione di moto IM    inviato al  quadro di manovra esterno solo per il tempo in cui l ostacolo    presente     6 4 3  Costola meccanica    Questo dispositivo    collegato direttamente all ingresso KN del controller in modo da gestisce l eventuale aper   tura di emergenza della porta  Il segnale di inversione di moto IM viene inviato dal controller al monitor del  quadro di manovra esterno fino a quando le porte non sono completamente aperte     6 5 Gancio di cabina  USA   Restrictor   Codice Param  05   Questa opzione    da impostare in presenza del dispositivo di bloccaggio delle porte di cabina e consente di ottimizza   re l
20.  505   rel 3    Edition 18 December 2009  7 TRIAL OPERATIONS BEFORE SETTING AT WORK    To avoid damages  check that the power supply voltage be within the rated values before starting up the door con   troller    Before the lift goes in operation  a self learning cycle must be carried out and parameters must be set according to the  General Options  as described in section 6    7 1 Self learning cycle   The self learning cycle allows the Door Controller to store the running distance between the closing and opening limit   It can only be activated manually and must be carried out under direct supervision of maintenance personnel so that  they may check that the operation is correctly completed  i e  the Door Controller must store the correct data   The  self learning cycle is shown on the door controller display with  SL      Important     During the self learning cycle please check carefully that the door panels slide freely and that the Door Operator com   pletes its total expected travel   The self learning cycle is essential if a replacement Door Controller has been installed     If a car door locking device is installed  car door locking device section 6 5  the self learning cycle must be carried  out with the operator coupled to a landing door  Outside the lock release zone of the landing doors  this device pre   vents the car door opening   Every time the system is re powered  for instance after power supply interruption  it performs a reset cycle  i e  it  searches a c
21.  6 13 Rotazione motore in chiusura  Codice Param  22    Questo parametro serve per impostare il senso di rotazione del motore durante il comando di chiusura  il valore impo   stato come default  0  determina una rotazione oraria del motore durante la chiusura  il valore  1  di questo parame   tro determina una rotazione antioraria del motore durante la chiusura     6 14 Scelta motore   Il controller Sematic Drive System pu   essere utilizzato con diversi motori Sematic indicati al 8 4 1  nei gruppi DC   Brushless e Brushless Plus   Come impostazione di default il controller riconosce automaticamente il tipo di motore  installato da una lista di motori utilizzati da Sematic come motori standard    In caso di necessit      comunque possibile manualmente selezionare il tipo di motore da una lista ulteriore predefinita   vedi 8 9 13 per la lista dei motori      6 15 Scelta tipo di stazionamento in chiusura  Codice Param  25   Questo parametro serve per impostare la modalit   preferita di stazionamento in chiusura     6 15 1 Stazionamento a scivolo chiuso  default   Il motore    alimentato durante lo stazionamento a porte chiuse  le lame dello scivolo dell operatore sono serrate     6 15 2 Stazionamento a scivolo aperto   Questa opzione    stata introdotta per diminuire annullare l assorbimento di potenza dell impianto  quindi pre   servare l utilizzo del motore  quando si trova a porte chiuse     Nota importante  durante la corsa della cabina    necessario che il quadro di manovr
22.  DATA   DATA DOWNLOAD   DATA UPLOAD   SMOOTH REOPENING    Using keys    and    run through the menu and choose the  SMOOTH REOPENING OPTION     Using the  OK  key  confirm the option  e On the display the following option are viewed   e 00   gt  disable  Default      01  gt  able  e Using keys            run through menu and choose the required option  e Using the  OK  key  confirm the option  The dispay show the confirmed option    e The following options are available   e  BACK   press key F1 to restore the Main Menu  e    MENU     press key      to restore the Main Menu    LIFT DOORS    a      e     5                o          o  a                  8  o  c  s  o       SEMATIC    All rights reserved     808 000 000 505  rel 3     Edition 18 December 2009  9 GENERAL OPTIONS    Connect the handset to RJ45 connector    If necessary  using keys    and   choose the required language and confirm with the    OK    key   Using keys 4 and   run through the MAIN MENU and choose GENERAL OPTIONS   Press OK to confirm the choice   The GENERAL OPTION menu allows the Door Controller to operate by means of the following parameter options        REVERSING SYSTEM   MAIN LIFT CONTROLLER TEST  NO MLC SIGNAL   MLC INPUT ALARM   KN INPUT   CAR DOOR LOCKING DEVICE  GLAZED AND HEAVY PANELED DOORS  AUX OUTPUT RELAY   FIRE FIGHTING OPTIONS  EOD TIMEOUT   PROTECTIVE DEVICE LOGIC  CLOSING ROTATION   MOTOR   CLOSING PARKING MODE  TYPE OF CLOSING PARKING  TYPE OF SKATE   AUX INPUT   IM SIGNAL TYPE    Th
23.  Drive System   DC PWM e AC VVVF Brushless   4 2 Connessioni Sematic Drive System   AC VVVF Brushless Plus   4 3 Configurazione Sematic Drive System  e segnali di entrata uscita del controller  4 4  Detector Fotocellule Barriere  collegamento di solo segnale al controller  collegamento diretto   4 5  Detector Fotocellule Barriere  collegamento completo al controller  5 MODALITA DI FUNZIONAMENTO SENZA L UTILIZZO DEL TASTIERINO pag     Visualizzazioni sul display in Modalit   Automatica e in Modalit   Manuale    5 1 Modalit   Automatica    AUTO     5 2 Modalit   Manuale  MAN   5 3 Modalit   di programmazione    PROG     5 4 Verifica del corretto funzionamento del controller SDS  DESCRIZIONE FUNZIONALIT   UTILIZZABILI pag   6 1 Inversione di moto  6 1 1 Forza d inversione di moto  Codice Param  09   6 1 2 Offset di inversione di moto  6 2 Scelta modalit   inversione di moto  INTERNA o ESTERNA  Codice Param  00   6 3 Test quadro di manovra  Codice Param  01   6 3 1 Test Quadro di Manovra  In Movimento   Default   6 3 2 Test Quadro di Manovra  in movimento   stazionamento   6 3 3 Mancanza Quadro di Manovra  Codice Param  02   6 3 3 1 Stop Immediato  6 3 3 2 Bassa velocit       stop  6 3 3 3 Ciclo bassa velocit    6 3 4 Allarme Quadro di manovra  Codice Param  03   6 4 Ingresso Kn  Codice Param  04   6 4 1 Tipo Default  6 4 2 Apertura parziale  6 4 3  Costola meccanica  6 5 Gancio di cabina  USA   Restrictor   Codice Param  05   6 6 Porte con pannelli in vetro totale  vetro intelai
24.  FUNZIONALIT   UTILIZZABILI    6 1 Inversione di moto  Parametro di gestione della funzionalit   di inversione di moto durante il ciclo di chiusura della porta  Si suddivide in     6 1 1 Forza d inversione di moto  Codice Param  09    Il parametro forza d inversione di moto    il parametro che fissa la sensibilit   di rilevamento di un ostacolo duran   te la chiusura delle porte  tale da richiederne l apertura  Il valore di questo parametro pu   essere impostato  manualmente    Si noti che a valori pi   elevati corrisponde una minore sensibilit    e viceversa  Dopo un certo periodo di funzio   namento  tale parametro potrebbe per   essere diverso poich      attivo un sistema di regolazione automatica     6 1 2 Offset di inversione di moto   Il dato impostato rappresenta la quota di spazio  espressa in percentuale  di disabilitazione della funzione di   Inversione di moto   Diminuendo la percentuale  valori    10096  il controller    in grado di migliorare da reat   tivit   del sistema in situazioni di inversioni di moto anche con ostacoli di ridotte dimensioni     6 2 Scelta modalit   inversione di moto  INTERNA o ESTERNA  Codice Param  00   Se l inversione di moto    INTERNA  la riapertura delle porte  per rilevamento di un ostacolo     gestita dal controller e  segnalata al quadro di manovra tramite il rel   IM  contatti 1 4 normalmente chiusi  2 4 normalmente aperti    Se l inversione di moto    ESTERNA IN MOVIMENTO  il controller segnala tramite il rel   IM la presenza di
25.  Kn setting by means of the Handset  See 8 6 12 for the meaning of this parameter   Using keys    and    run through the GENERAL OPTIONS and choose the Protective Device Logic Option  Press the  OK  key to confirm the choice   The following options are viewed on the display     ON OBSTRUCT    CLOSED  ON OBSTRUCT    OPEN    Using keys 4 and    choose the required option and press the  OK  key to confirm it  The display shows the confirmed option and restores the menu GENERAL OPTIONS  The following options are available      BACK   Press key F1 to restore the menu PROFILE SETTING   MENU   Press key F3 to restore the MAIN MENU    9 12 Closing Rotation by means of the Handset  See 8 6 13 for the meaning of this parameter  Using keys    and V  run through the GENERAL OPTIONS and choose the CLOSING ROTATION Option  Press the  OK  key to confirm the choice   The following options are viewed on the display     CLOCKWISE  ANTICLOCKWISE    Using keys    and    choose the required option and press the  OK  key to confirm it  The display shows the confirmed option and restores the menu GENERAL OPTIONS  The following options are available      BACK   Press key F1 to restore the menu PROFILE SETTING   MENU   Press key F3 to restore the MAIN MENU          LIFT D O O R S          SEMATIC    All rights reserved   Changes can be made without notice     33       a        e       Di                   o             o  a                              o   c   s  o       SEMATIC    All rights reserve
26.  and the connector 15   24 V  are activated for the direct use of a 24  Vdc max 100 mA buzzer  device not supplied by Sematic  or adequate relay     6 9 Fire Fighting  Param  Code 19    The FIRE FIGHTING option is possible for specific installations where the main lift controller contains the applicable func   tions    For operative details of the complete lift installation  refer to the following standards     BS5588  Part 5  1991  EN81 72  2003  ASME A17 1  2000  AS 1735 1  2003    The Fire Fighting option has a dedicated input  Kff   When Kff switches from OPEN to CLOSED the directly or completely connected light barriers or similar devices are igno   red  as these are assumed to be devices which may be affected by smoke or heat due to fire conditions  the reopening  system can be set to either ignore mechanical obstacle  parameter 19   0  or to have its sensitivity reduced  para   meter 19   1    Warning  the default setting is    reduced sensitivity     parameter 19   1   Change of this parameter is according to  customer s choice  following careful assessments and check of the standards required in the Country of installation     At the end of the first closing cycle the main lift controller takes the car to the Fire Fighters  access floor  if it is not    already there   The Sematic Drive System  Door Controller operates only on signals coming from the main lift controller  Even during    the opening cycle it is possible to reverse the movement by deactivating the Ka s
27.  be familiar with the General and  Specific regulations in force on the subjects of work safety and hygiene  89 391 CEE   89 654          89 656            e personnel responsible for the installation and or maintenance must be familiar with the Sematic product and must  have been trained by Sematic or by an authorized Sematic agent    e installation equipment used must be in good working order with all measuring instruments calibrated  89 655 CEE      Sematic    e undertakes to update the present manual and send the customer copies of all new updates together with material    e within its continuous product improvement policy  reserves the right to make changes to the designs and materials  of its products  Sematic will give an agreed reasonable time to all its customers to allow them to adapt to the new  changes their complementary current constructions       guarantees a good performance only of the original parts sold directly and correctly installed     Therefore    parts manufactured and or added to the Sematic product without his direct control  or non original parts based upon  a Sematic design  even if supplied by authorised agents  cannot be considered under guarantee since the following con   ditions have not been ensured     1 Quality control of raw material supply   2 Process control   3 Product control   4 Conformity tests according to Sematic specifications    Furthermore  Sematic    e guarantees the performance life of its products only if correctly stored  in
28.  by means of the Handset  9 7 Activation of the Glazed and Heavy Paneled Doors setting by means of the Handset  9 8 AUX Output Relay setting by means of the Handset  9 9 Fire Fighting Option setting by means of the Handset  9 10 EOD Timeout setting by means of the Handset  9 11 Protective Device Logic Kn setting by means of the Handset  9 12 Closing Rotation by means of the Handset  9 13 Motor type by means of the Handset  9 14 Closed parking Mode by means of the Handset  9 15 Skate type setting by means of the Handset  9 16 AUX input setting by means of the Handset  9 17 IM signal type setting by means of the Handset  MAINTENANCE MENU   DIAGNOSTICS AND ALARM MANAGEMENT pag   10 1 Consulting the Maintenance Menu with the Handset  CONTROLLER SOFTWARE UPGRADE pag   DOOR OPERATOR MAINTENANCE pag   SPARE PARTS pag     6 15 6 PM position control   Skate Type  Param  Code 26    AUX Input  Param  Code 32    6 17 1 Disables  default    6 17 2   Partial Reopening   IM  reversing motion  signal type  Param  Code 34   6 18 1 IM pulse   6 18 2 IM continuous  default    6 18 3 Monostable pulse   Alarms    Self learning cycle          LIFT DOORS    23    24    31    36    37  37  37    808 000 000 505  rel 3     Edition 18 December 2009  1 PREFACE    This manual has been drafted taking into account that the Company installing genuine Sematic products will comply   with the following necessary requirements       personnel responsible for the installation and or maintenance of the doors must
29.  e che l operatore effet   tui tutta la corsa prevista    Il ciclo di autoapprendimento    particolarmente importante nel caso di installazione di un controller di ricambio      Nel caso sia installato il dispositivo di blocco di porta di cabina  gancio di cabina 8 6 5  il ciclo di autoapprendimento  deve essere effettuato accoppiando l operatore ad una porta di piano  Fuori dalla zona di sbloccaggio delle porte di  piano  il dispositivo impedisce l apertura delle porte di cabina      Ogni volta che si alimenta di nuovo il sistema  per esempio dopo un interruzione della tensione  il sistema effettua  un ciclo di reset  cio   ricerca un limite di corsa di chiusura a bassa velocit    e non il ciclo di autoapprendimento     7 2 Attivazione del ciclo di Autoapprendimento con controller  senza l utilizzo del tastierino    e Alimentare il sistema    e Accendere il controller  ON      Per la procedura di autoapprendimento in modalit   manuale premere per alcuni istanti il tasto 4 per passare da moda   lit   automatica a modalit   manuale  verificare che il led AUTO si spenga e il led MAN si accenda       Per iniziare la procedura di autoapprendimento premere per alcuni istanti il tasto 1  SELF LEARN    e La apertura e la chiusura vengono comandate dai pulsanti 2  apertura  e 3  chiusura  posti sul controller     Su comando di chiusura il controller effettua un ciclo di chiusura a bassa velocit    il display sul controller visualizza la  scritta  SL   ovvero rimane in posizione di ch
30.  for a set time  and then close  all  with normal opening closing speed profiles  According to this requirement Sematic offers to its Customers as an extra  option the Sematic E O D   Emergency Opening Device     When the Sematic Drive System   controller is powered by battery  the KEOD input allows a signal to open the doors at  the proper time  when the car is brought to a designated escape floor  After set disactivation   see parameter 20 disac   tivation time E O D   the controller closes the doors  in order to save battery life     A magnetic switch  option   mounted on the Door Operator by Sematic  is connected to the 15 40 con   nectors and is operated by magnets  option  mounted on the designed emergency landing door by means  of a special support plate  see drawing     This signal allows the door controller to open the doors    Please refer to the specific instruction Sematic 301 036 000  BATTERY KIT AND ACTIVATOR FOR AUTO   MATIC EMERGENCY OPENING DEVICE  SEMATIC EOD  FOR SEMATIC DRIVE SYSTEM  rel  3         6 12 Protective Device Logic Kn  Param  Code 21    This parameter sets the logic on the protective device input Kn  Photocells  optical barrier      its default value  0   means that the contact is open in normal condition and it is closed to signal the presence of an obstacle  the alterna   tive value  1  reverses the logic  i e  the contact is closed in normal conditions and it opens to signal the presence of    an obstacle     WARNING  if the selected logic i
31.  relativo allarme gestito dal controller                                                        TABELLA ALLARMI  Codice Errore Descrizione dell errore Azione intrapresa dal controller  visualizzato   visualizzato  a display   01 Mancanza quadro di Quadro di manovra scollegato  Nota 1  Auto reset al ripresentarsi delle condizioni   manovra normali di funzionamento    02 Sovracorrente Sovracorrente del motore per sforzo meccanico eccessi    Auto reset dopo circa 10 secondi  in base   vo della porta  Nota 2  al motore installato    03 Mancata Inversione Il quadro di manovra non invia il comando di riapertura   Chiusura a bassa velocit     dopo che il controller gli ha segnalato la presenza di un  ostacolo  Nota 3    04 Motore invertito Connessione motore invertita oppure canali Encoder del   Auto reset  dopo circa 10 secondi  se si sono  motore invertiti  ristabilite le normali condizioni di funziona   La porta effettua uno strappo e si ferma  Nota 4   mento  dopo 5 tentativi in 5 minuti il sistema  si ferma   05 Strappo Encoder Interruzione dei cavi dell encoder del motore  oppure   Auto reset dopo 5 secondi  dopo 5 tentativi  interruzione dei cavi del motore avvenuta successiva    in 5 min  il sistema si ferma  mente all accensione del sistema oppure il plug di con   nessione dell encoder sul motore    invertito   06 Allarme Termico Sovrariscaldamento del motore  per motori dotati di Autoreset al ripresentarsi delle condizioni  Motore sensori PTC interni  normali di funzioname
32.  scivolo  cod  26  Richiama Profilo Y       Ingresso AUX  cod  32    Y    Tipo di segnalazione IM  Upload Dati cod  34       Download Dati                                     Riaperture dolci             Y    Reset parametri di fabbrica    Y    Area riservata                   SEMATIC    All rights reserved   Changes can be made without notice                    LIFT DOORS          SEMATIC    All rights reserved     ES  2  e  2  5  3                 S  E                 8      8      s  o    26    808 000 000 505   rel 3    Edition 18 December 2009   8 3 Attivazione del ciclo di autoapprendimento con tastierino   Utilizzando il tastierino per comandare un ciclo di autoapprendimento si ha la certezza di evitare interferenze con even    tuali segnali provenienti dal quadro di manovra    e Alimentare il sistema       Accendere il controller  ON   se sono presenti segnali di chiusura o di apertura provenienti dal quadro di manovra   l operatore effettuer   il relativo ciclo di reset in bassa velocit    fino al limite corsa  se non sono presenti segnali verr     effettuato un ciclo di reset di chiusura e l operatore si posizioner   al limite di chiusura    Collegare il tastierino al connettore RJ45   Utilizzando i tasti 4 e   posizionarsi sulla lingua desiderata e confermarla con il tasto OK    Con i tasti 4 e W scorrere il MENU PRINCIPALE e posizionarsi su AUTOAPPRENDIMENTO   Con il tasto OK confermare la scelta    Se l operatore non    in posizione di chiusura premere il tasto F
33.  seguenti opzioni    e IMPOSTAZIONI RAPIDE   INVERSIONE DI MOTO   IMPOSTAZIONI AVANZATE   RESET PARAMETRI DI FABBRICA   AREA RISERVATA          LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice     27          a             c   5                   o             o  5                              o   c   s  o       SEMATIC    All rights reserved     28    808 000 000 505   rel 3    Edition 18 December 2009  e Utilizzando i tasti      W scorrere il men   di IMPOSTAZIONE PROFILI posizionandosi sull opzione AREA RISERVATA   e Confermarla premendo il tasto OK     Dopo la conferma della scelta tramite il tasto OK verr   richiesto dal display di inserire una password di cinque cifre   Questa selezione    disponibile solo per il costruttore    Per inserire le cifre utilizzare i tasti     e    per selezionare la cifra che si desidera inserire    modificare il valore di que   sta con    e V     8 9 Opzione  Impostazioni Avanzate    e Collegare il tastierino al connettore RJ45    Utilizzando i tasti 4 e   posizionarsi sulla lingua desiderata e confermarla con il tasto OK    Con i tasti 4 e   scorrere il MENU PRINCIPALE e posizionarsi su IMPOSTAZIONE PROFILI    Premere OK per confermare la scelta    Sul display verranno visualizzate le seguenti opzioni    e IMPOSTAZIONI RAPIDE      FORZA DI INVERSIONE DI MOTO      IMPOSTAZIONI AVANZATE   e RESET PARAMETRI DI FABBRICA      AREA RISERVATA   e Utilizzando i tasti 4 e   scorrere il men   di IMPOSTAZIONE PROF
34.  the   partial opening  of a door  set in percentage  for a particular plan or with a control  key  The    Aux Input    is able and the controller open the door  after the open command  until to percentage of    self learning space    6 18 IM  reversing motion  signal type  Param  Code 34   This parameter allow to choose 3 different signals to manage the IM  reversing motion  coming from external to main    lift controller     6 18 1 Im pulse   The IM  reversing motion  is active until KA  door opening relay  arrive from MLC  main lift controller       6 18 2 IM Continuous  default    IM  reversing motion  is active up to the end of complete opening of a doors LA  contact limit open doors      6 18 3 Monostable pulse   IM  inversion of movement  is active only for a preset time of 0 5  sec   After this time interval the output is    disabled        SEMATIC    All rights reserved   Changes can be made without notice      d       LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009  6 19 Alarms    The Sematic Drive System   controller has the ability to diagnose and record a number of defects  such diagnostics is       very helpful to the maintenance personnel in order to locate possible operational problems   When any monitored error occurs  the Door Controller display will signal it and the error code will show     The following table illustrates the type of signalling and the relevant alarm detected by the Door Controller                                         
35.  un ostacolo al  quadro di manovra  che deve dare il segnale di riapertura tramite il comando Ka  Il segnale IM rimane presente fino  alla completa riapertura della porta   Se il quadro di manovra non invia un segnale di riapertura durante il movimento delle porte il controller comanda  una chiusura in bassa velocit     Se le porte sono completamente aperte con la presenza di un ostacolo  il controller permette la chiusura delle porte  solo se viene dato dal quadro di manovra un segnale di chisura forzata Kb   Se l inversione di moto    ESTERNA IN MOVIMENTO STAZIONAMENTO il controller segnala tramite il rel   IM la presen   za di un ostacolo al quadro di manovra  che deve dare il segnale di riapertura tramite il comando Ka  Il segnale IM rima   ne presente fino alla completa riapertura della porta   Se il quadro di manovra non invia un segnale di riapertura il controller comanda una chiusura in bassa velocit       Se le porte sono completamente aperte con la presenza di un ostacolo  il controller permette la chiusura delle porte se  viene dato dal quadro di manovra un segnale di chisura forzata Kb oppure se viene dato un segnale di chiusura Kc  in  quest   ultimo caso il controller comanda una chiusura in bassa velocit   mostrando un allarme di    mancata inversione         6 3 Test quadro di manovra  Codice Param  01    Qualora il TEST QUADRO DI MANOVRA sia disattivato    OFF        sufficiente un comando Ka o Kc di tipo impulsivo per  comandare il movimento della porta  il 
36. 05   rel 3    Edition 18 December 2009    8 9 1 Opzione    Parametri Apertura     Sul display vengono visualizzate i seguenti parametri      BASSA VELOCITA INIZIO     INIZIO RAMPA ACCELERAZIONE  e ACCELERAZIONE  e ALTA VELOCIT        OFFSET DECELERAZIONE      DECELERAZIONE   e BASSA VELOCITA   e RACCORDI    Per ognuno dei parametri  il nome    visualizzato nella parte alta del display  mentre il valore corrente e la sua  unit   di misura nella parte in basso  con i tasti 4 e W    possibile variare il valore corrente      Sono disponibili le opzioni    e    BACK     premendo il tasto F1 si ritorna al men   MENU PRINCIPALE   e  F2   premendo il tasto F2 si apre oppure si chiude la porta per verificare il profilo impostato       MENU   premendo il tasto      si ritorna al MENU PRINCIPALE       8 9 2 Opzione  Parametri Chiusura   Sul display vengono visualizzate i seguenti parametri      BASSA VELOCITA INIZIO  e FINE RAMPA DECELERAZIONE  e ACCELERAZIONE  e ALTA VELOCITA   e OFFSET DECELERAZIONE      DECELERAZIONE   e BASSA VELOCITA   e RACCORDI    Per ognuno dei parametri  il nome    visualizzato nella parte alta del display  mentre il valore corrente e la sua  unit   di misura nella parte in basso  con i tasti 4 e      possibile variare il valore corrente      Sono disponibili le opzioni    e  BACK  premendo il tasto F1 si ritorna al men   MENU PRINCIPALE   e  F2   premendo il tasto F2 si apre oppure si chiude la porta per verificare il profilo impostato   e  MENU   premendo il 
37. 1  24 Vdc Vdc power supply to detector   photocell barrier  riers  Muth transmitter and 30 NC dummy free connector pin  receiver connecte ia    Tx   between themselves throu      py  it can be used as a dummy connector for connection between the  tor pin 30  detectors system components                        The operating reopening modes depend upon the setting of the REVERSING SYSTEM  LIMITED DOOR REVERSAL EFFECT  and PROTECTIVE DEVICE LOGIC settings  see section 6 2  6 3 and 6 12         SEMATIC    All rights reserved   Changes can be made without notice     LIFT DOORS          SEMATIC    All rights reserved     a      e         gt                    o             o  5                       8   o           o    14       808 000 000 505   rel 3    Edition 18 December 2009  5 INSTRUCTIONS WITHOUT HANDSET  Display in Automatic and Manual Mode      Sematic    Drive    5 1 Automatic Mode  AUTO    e When the Door Controller is working in automatic mode the    AUTO    red led is on  whereas the other two red leds  are off    e When the Door Controller is switched on  or after a self resetting  it starts directly in the automatic mode      All the signals sent by the main lift controller and by the external devices  barriers  photocells  etc   are active in this   mode    Keys 2 and 3 are not functional during automatic mode    Key 1 selects Self Learning Cycle    When Key 4 is kept pressed for a while  the Door Controller  ca  3 sec    switches to the manual mode  MAN             
38. 2   gt  lt   per permettere alla porta di assicurare le chiu    sura in bassa velocit      e Una volta assicurata la chiusura premere nuovamente il tasto F2   lt  gt   per effettuare un apertura completa in bassa  velocit       Durante questa fase verificare attentamente che l operatore effettui la corsa completa   Al termine del ciclo d apertura il ciclo d autoapprendimento    ultimato   Questo verr   segnalato dalla scritta   AUTOAPPRENDIMENTO COMPLETATO        Verr   inoltre richiesto   IMPOSTAZIONE PROFILI GUIDATA          Premendo il tasto OK si acceder   all opzione  IMPOSTAZIONI RAPIDE      Premendo il tasto F1  EXIT  si ritorner   al MENU PRINCIPALE        8 4 Impostazione Forza d inversione di moto con tastierino   e Collegare il tastierino al connettore RJ45    Utilizzando i tasti 4 e   posizionarsi sulla lingua desiderata e confermarla con il tasto OK    Con i tasti    e W scorrere il MENU PRINCIPALE e posizionarsi su IMPOSTAZIONE PROFILI    Premere OK per confermare la scelta    Sul display verranno visualizzate le seguenti opzioni    e IMPOSTAZIONI RAPIDE   e INVERSIONE DI MOTO   e IMPOSTAZIONI AVANZATE   e RESET PARAMETRI DI FABBRICA   e AREA RISERVATA   e Utilizzando i tasti 4 e   scorrere il men   di IMPOSTAZIONE PROFILI posizionandosi sull opzione INVERSIONE DI  MOTO    e Confermarla premendo il tasto OK    e Utilizzando i tasti        scorrere il men   di INVERSIONE DI MOTO posizionandosi sull opzione    FORZA DI  INVERSIONE DI MOTO       Confermarla premend
39. 2 Manual Mode                When the Door Controller is working      manual mode the              red led is       whereas the other two red leds  are off    e All signals coming from the main lift controller and from other external devices are ignored    The IM contact is deactivated  therefore the Door Controller does not recognize any signal coming from the external  devices to reverse door movement  such as photocells or barriers    Opening and Closing commands may be manually input by pushing Key 2  open  or Key 3  close     Key 1 selects Self Learning Cycle    When key 4 is kept pressed for a while  Appx  3 sec    the Door Controller switches to the automatic mode  AUTO    If no keys are pressed for at least 10 minutes  the Door Controller will switch to the  automatic mode  AUTO                     3  ty  z  et  o  3  ty     o  ty  3       3  ty  3      Dr  3      a      et                                3  et                                E  et              E  o  5  5      2  a     ty   lt     Door opening  Flashing Display     Door open    Door closing  Flashing Display     Door Closed    Self Learning    Forced Closing    It signals an alarm and flashes giving the code of the recognised alarm  See chapter 10     SIZ        pi hj          O   3    al lo  JE        AUS ZIN    Reversing system on    5 3 Programming Mode    PROG      e When the Door Controller is working in    programming mode    the    PROG    red led is on whereas the other two red leds  are off    
40. 3      6 3 2 Test Quadro di Manovra  in movimento   stazionamento    Qualora il TEST QUADRO DI MANOVRA sia impostato  IN MOVIMENTO   STAZIONAMENTO     il controller verifi   ca la presenza del segnale Ka o Kc proveniente dal quadro di manovra sia durante il movimento  durante il ciclo  d apertura del segnale Ka  durante il ciclo di chiusura del segnale Kc  sia durante lo stazionamento  in apertu   ra del segnale Ka  in chiusura del segnale Kc     Questa impostazione    prevista per quadri di manovra che posseggono 1 rel   unico per comandare apertura e  chiusura    Il controller rileva cadute di segnali maggiori di 200ms e le interpreta come Allarme MANCANZA QUADRO DI  MANOVRA se il parametro corrispondente TEST QUADRO DI MANOVRA    impostato    IN MOVIMENTO      STAZIONAMENTO      Nel caso di mancanza del segnale  il controller si comporta secondo l impostazione del parametro MANCANZA    QUADRO DI MANOVRA  vedere 8 6 4 3      LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice     17             SEMATIC    All rights reserved     ES  2      2  5  3                 S  E      a  E      8      8      s  o    18    808 000 000 SDS  rel 3  Edition 18 December 2009  6 3 3 Mancanza Quadro di Manovra  Codice Param  02   Questo sottomen   non    accessibile se il parametro TEST QUADRO DI MANOVRA ha l impostazione  OFF    In caso di impostazione del TEST QUADRO DI MANOVRA  questo menu permette di selezionare il comportamento  che il controller deve ave
41. 5AAIX   Brushless   BG62x30 SG80K  e  B105AAJX   Brushless   BG62x60 SG120  e B105AALX   Dc   GR63x55 SG120   e B105AANX   Dc   GR63x25 SG80K          LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice           SEMATIC    All rights reserved        a  2  e  2  5                8            2  a          8      8                      808 000 000 505   rel 3    Edition 18 December 2009  Taking into account  during all project planning  the Risk Assessments relating to     A     RISKS OF MECHANICAL HAZARDS      Squeezing during operations   e Squeezing after Trapping caused by friction  glass panels   e Cuts caused by sharp edges  or static sharp pieces    RISKS OF ELECTRICAL HAZARDS     Persons in contact with energized parts  direct contact     e Persons in contact with parts that become energized due to a fault  indirect contact       RISKS OF OVERHEATING      RISKS GENERATED BY NOISE    RISKS GENERATED BY VIBRATION      RISKS GENERATED BY MATERIALS AND SUBSTANCES          LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    2 WHAT IS THE SEMATIC DRIVE SYSTEM           5 V  m s                                                  The System consists of    e a Car Door Operator  1    e a microprocessor based Door Controller  2    e DC  brushed or brushless type  Motor  3  with feedback signals  4     e A 500 VA or 750 VA 230 400 Vac   10   primary  and 36 Vac   10    secondary  transformer  only for Brushless Plus controller versi
42. 6 3 2 Main Lift Controller Test  when moving   parking    If the main lift controller test is set to MOVING PARKING  the Door Controller checks for the Ka or Kc signals  coming from the main lift controller both during movement  Ka signal during the opening cycle  Kc signal during  the closing cycle  and during parking  Ka signal while opening  Kc signal while closing     This test setting should only be applied for main lift controllers that are equipped with just 1 relay to command  both opening and closing     The Door Controller detects signal drops exceeding 200ms  this is interpreted as NO MAIN LIFT CONTROLLER    INPUT alarm if the relevant parameter MAIN LIFT CONTROLLER TEST is set on  MOVING  PARKING    In case of signal failure  the Door Controller acts as described in the parameter setting NO MAIN LIFT CON     TROLLER SIGNAL  see 8 6 4 3    sematic  LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice     17          a        e     5                o          o  5                    8  o      s  o       SEMATIC    All rights reserved     18    808 000 000 505   rel 3    Edition 18 December 2009  6 3 3 No MLC Signal  Param  Code 02   This submenu is not available if the parameter MAIN LIFT CONTROLLER TEST is set to  OFF    If the MAIN LIFT CONTROLLER TEST is set either to  WHEN MOVING    or to  WHEN MOVING PARKING    this  menu allows the selection of the Door Controller behaviour that must be adopted in case of signal loss or failu   
43. ACK   Press key F1 to restore the menu PROFILE SETTING   e  MENU   Press key      to restore the MAIN MENU          LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    9 17 IM Signal type setting by means of the Handset      See 8 6 18 for the meaning of this parameter   e Using keys 4 and V run through the GENERAL OPTIONS and choose the IM SIGNAL Option  e Press the  OK  key to confirm the choice   e The following options are viewed on the display    e IM PULSE   e      CONTINUOUS   e MONOSTABILE IMPULSIVA   Using keys 4 and V  choose the required option and press the    OK    key to confirm it  The display shows the confirmed option and restores the menu GENERAL OPTIONS  The following options are available     BACK   Press key F1 to restore the menu PROFILE SETTING   e  MENU   Press key      to restore the MAIN MENU          SEMATIC    All rights reserved   Changes can be made without notice      d       LIFT DOORS       a      e       5                   o             o  a        Si               8   o        s  o       SEMATIC    All rights reserved     36    808 000 000 505   rel 3    Edition 18 December 2009  10 MAINTENANCE MENU   DIAGNOSTICS AND ALARM MANAGEMENT    10 1 Consulting the Maintenance Menu with the Handset  e Connect the handset to the RJ45 connector  e If necessary  using keys      and    choose the required language and confirm with the  OK  key or confirm the sug   gested language with  OK   e Using keys Up Arrow  and     run through the
44. ADOTTATA    for changes or additions to the product  please see the foreword of this handbook  Sematic will not accept any debit  note and will not be responsable for changes which have been made without our written approval     per modifiche o aggiunte al prodotto vale quanto indicato nella premessa al presente manuale  Sematic non accetter   addebiti  n   si riterr   responsabile per modifiche eseguite senza nostra approvazione scritta     DESCRIPTION OF THE PROPOSED REVISION  DESCRIZIONE DELLA PROPOSTA DI REVISIONE    ENCLOSURES  ALLEGATI       SEMATIC    All rights reserved   Changes can be made without notice         d       T sematic  LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009       5              55  5              at        Ss  28         lt      DEE      25                 8  nD  2  Os  E            d       sematic i  LIFT DOORS    808 000 000 508 rel 3    Edition 18 December 2009       5         3        HE  8 3        ae        co          9  ce  2  338  25        25  Ds  coc   E              e                LIFT DOORS                                  PeR E a   lt  H  gt                                                                                                                          O            MyM          gt   s       U               2  _                     www sematic com    FFF UNI EN ISO 9001  21 APPROVED BY IMQ 0051  EENet        PT EAR pane      lodule  7 ISO 14001              A MEMBER                     sb   w            B
45. ALI consente di caratterizzare il funzionamento del controller attraverso le scelte dei  seguenti parametri     SCELTA MODALIT   INVERSIONE DI MOTO  TEST QUADRO DI MANOVRA   MANCANZA QUADRO DI MANOVRA  ALLARME QUADRO DI MANOVRA  INGRESSO KN   GANCIO DI CABINA   PORTE IN VETRO E PORTE PESANTI  USCITA AUX   OPZIONI FIRE FIGHTING   TIMEOUT EOD   LOGICA INGRESSO KN   ROTAZIONE IN CHIUSURA   MOTORE   TIPO STAZIONAMENTO IN CHIUSURA  TIPO SCIVOLO   INGRESSO AUX   TIPO DI SEGNALAZIONE INVERSIONE DI MOTO       Il significato e l impostazione di questi parametri sono dettagliati nei paragrafi che seguono     9 1 Impostazione dell attivazione dell inversione di moto con tastierino  e Per il significato di questo parametro vedere il 8 6 1  e Utilizzando i tasti 4 e V scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione SCELTA MODALIT               Confermarla premendo il tasto OK   e Sul Display verranno visualizzate le seguenti opzioni      INTERNA   e ESTERNA IN MOVIMENTO  e ESTERNA IN MOVIMENTO STAZIONAMENTO   e Utilizzando i tasti 4 e W posizionarsi sulla opzione desiderata e confermarla con il tasto OK   e Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI      Sono disponibili le opzioni   e  BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI   e    MENU     premendo il tasto      si ritorna al MENU PRINCIPALE     9 2 Impostazione dell attivazione dell INGRESSO KN con tastierino    Peril significato di questo parametro ve
46. E BUTTON   PUSH AT INSTALLATION   TASTE F  R SELBSTLERNZYKLUS   BEI INSTALLATION DR  CKEN   TASTO PER CICLO DI AUTOAPPRENDIMENTO   PREMERE ALLA INSTALLAZIONE     110V 230V  LEAD FREE L  RoHS Compliant    0          Directive 2002 95 EC  COD  H147AASXO1 1          4 2 Connessioni Sematic Drive System   AC VVVF Brushless Plus     SDS   AC VVVF Brushless Plus              s                ELEVATOR PRODUCTS      FOR FURTHER INFORMATION REFER TO THE USER S GUIDE    FUR WEITERE INFORMATIONEN BENUTZEN SIE BITTE DAS HANDBUCH    EMC PROTECTION   PER MAGGIORI INFORMAZIONI RIFERIRSI AL MANUALE UTENTE               DOOR OPENING RELAY Kc         I    DOOR CLOSING RELAY    OFFNUNGS RELAIS   I    SCHLIESS RELAIS  RELE  DI CHIUSURA    PNP N O    KEEP CLOSED   GESCHLOSSEN HALTEN   MANTENERE CHIUSO   OPENING LIMIT Lc CLOSING LIMIT  Liza T  RE AUF ENDKONTAKT T  RE ZU ENDKONTAKT  DETECTOR  LIMITE APERTURA LIMITE CHIUSURA  PHOTOCELL    RELE  DI APERTURA                  DOUBLE      RELAY  DOPPELTE TB RELAIS  RELE  DI DOPPIO TB    Kaux AUXILIARY RELAY  ZUSATS RELAIS  RELE  AUSILIARIO    FIREFIGHTING RELAY  FEUERWEHR RELAIS  RELE  DI FIREFIGHTING      E O D  ACTIVATION RELAY  E 0 D  AKTIVIERUNG RELAIS  RELE  DI ATTIVAZIONE E O D   ENCODER  DOOR CLOSING RELAY IN SLOW SPEED  SCHLIESS RELAIS NIEDRIGE GESCHWINDIGKEIT  RELE  DI CHIUSURA IN BASSA VELOCITA    PHOTOCELL              s dc   INSIDE  1 Battery            24V  IM     OPTIONAL   REVERSE MOTION RELAY  LEAD FREE 1   NI   r1 wa cm          REVERSI
47. ERUNGS RELAIS    RoHS Compliant  Directive 2002 95 EC    RELE  DI INVERSIONE DI MOTO    SELF LEARNING CYCLE BUTTON    PUSH AT INSTALLATION    TASTE F  R SELBSTLERNZYKLUS    BEI INSTALLATION DR  CKEN    TASTO PER CICLO DI AUTOAPPRENDIMENTO   PREMERE ALLA INSTALLAZIONE        SEMATIC    All rights reserved     E  2  2  5  2         8  8      E  8     5  8      8  2  8  o    MOTOR       COD  H147AAYX 1         sematic  LIFT       DOORS    808 000 000 505   rel 3    Edition 18 December 2009    4 3 Configurazione Sematic Drive System  e segnali di entrata  uscita del controller       cod  B105AABXO1  IP54   1Nm Dc    cod  B105AAAXO1  IP23   1 Nm Dc    cod  B105AAAX02  IP23   2Nm Dc    cod    105          2  IP54   2Nm Dc    cod  B105AALX     IP54  opzione    Dc  GR63x55 SG120  cod  B105AAQX    cod  B105AANX     IP54  Opzione    Dc  GR63x25 SG80K  cod  B105AAPX             cod  B105AAJX     IP54  opzione   Brushless  BG62x60 SG120  cod  B105AARX    cod  B105AAIX     IP54  Opzione   Brushless  BG62x30 SG80K  cod  B105AATX    cod  B105AAHX     IP54  opzione   Brushless  BG62x60 PLG60       EOD Kit  optional     Tk   Tk    Catena delle  sicurezze       cod  B105AAGX  IP65   Brushless   Nota  questo motore     abbinato solo al con     troller in versione SDS  Brushless Plus              cod  B105AADX      con questi  IP54   EEx motori l operatore  Dc completo Sematic   Drive System      raggiunge il grado  di protezione IP43           Fotocellule  o Barriere                            
48. ILI posizionandosi sull opzione IMPOSTAZIONI  AVANZATE    e Confermarla premendo il tasto OK     Dopo la conferma della scelta tramite il tasto OK verr   richiesto dal display di inserire una password di cinque cifre  La  password impostata in fabbrica come default    00001    Per inserire le cifre utilizzare i tasti     e  gt  per selezionare la cifra che si desidera modificare  e utilizzare i tasti      V  per selezionare il numero  Premere Ok per confermare la password inserita     Sul display vengono visualizzate le seguenti opzioni   PARAMETRI APERTURA  PARAMETRI CHIUSURA  SPAZIO INVERSIONE  OPZIONI BUS SERIALE  MODIFICA PASSWORD  SALVA PROFILO  RICHIAMA PROFILO  DOWNLOAD DATI  UPLOAD DATI  RIAPERTURE DOLCI    Utilizzando i tasti 4 e W scegliere l opzione desiderata e confermare con il tasto OK la scelta      Sono disponibili le opzioni          BACK   premendo il tasto F1 si ritorna al men   MENU PRINCIPALE         MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE    Il diagramma seguente mostra la corrispondenza tra i profili di velocit   e i parametri impostabili     A  9 04                             gt   01  Bassa velocit   inizio C1  Bassa velocit   inizio  02  Inizio rampa accelerazione C2  Accelerazione  03  Accelerazione C3  Alta velocit    04  Alta velocit   C4  Offset decelerazione    5  Offset decelerazione C5  Decelerazione  06  Decelerazione C6  Fine rampa decelerazione  07  Bassa velocit   C7  Bassa velocit            LIFT DOORS    808 000 000 5
49. NZA DI PICCO 300 VA  PROTEZIONE SOVRACORRENTE MOTORE  In   15 minuti   2I    3 minuti  GAMMA DI TEMPERATURE da  10  C a  60  C  GRADO DI UMIDIT   non condensante tra 20  e 80   PROTEZIONE fusibile rapido a cartuccia  5x20  4 A   fusibile batteria  5x20  8 A   VELOCIT   DI FUNZIONAMENTO regolabile separatamente per apertura e chiusura  SENSIBILIT   DI INVERSIONE DI MOTO variabile  inserita nella sola fase di chiusura dei pannelli    3 2 Door Controller Sematic Drive System   DC PWM e AC VVVF Brushless     OPERATO   CONTR  Sematic            4                                caiano    Y ur       IE      6 8 9 10 11       Pulsante accensione   Pulsante spegnimento   Display   Pulsanti per modalit   manuale   Porta per connessione RJ45  Tastierino    Morsetto    6 poli per connessioni motore e alimentazione EOD  cod  E066AARX 05   Porta per connessione RJ45  Encoder Motore    Morsetto a 4 poli per connessione barriere detector  cod  E066AARX 06    Morsetto a 6 poli per connessione segnali Quadro di Manovra  cod  E066AARX 03   10 Morsetto a 6 poli per connessione segnali Quadro di Manovra  cod  EQ66AARX 04   11 Morsetto a 10 poli per connessione segnali Quadro di Manovra  cod  E066AARX 07      O   N Q U P Q N F        i        etc        88        25        52        oe   lt       5  38  25        zs  58  coc       Os   B   e            LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    3 3 Dati tecnici Sematic Drive System  Brushless Plus  AC VVVF Brushless Plus 
50. On the left display side three values are shown selectable with    and W keys  the maximum value  MAX   the set value   SET  and the minimum value  MIN     It is possible to change those values with     and  gt     On the right display side a graph is shown with the set force percentage regarding the maximum force     Using keys     and  gt  the viewed value is respectively decreased or increased    Press key F2               to check the door operation with the set reversing force value  Press key F3  MENU  to restore the MAIN MENU   Press key F1  BACK  to restore the menu PROFILE SETTINGS     8 5 Setting reversing system offset with the keypad      Connect the handset to RJ45 connector   If necessary  using keys    and    choose the required language and confirm with the  OK  key   Using keys    and    run through the MAIN MENU and choose PROFILE SETTING    Press the  OK  key to confirm the option    On the display the following options are viewed       FAST SETTING   e REVERSING SYSTEM   e ADVANCED SETTINGS   e SET FACTORY DEFAULT   e RESERVED AREA   e Using keys            run through the menu    PROFILE SETTING    and choose the option REVERSING SYSTEM   e Using the  OK  key  confirm the option   e Using the keys  amp  and    scroll through the REVERSING menu and select the option    REVERSING SYSTEM FORCE  SETTING    e Press  OK  to confirm the choice    At top right of the display the current set percentage is graphically shown  the value displayed can be decreased or 
51. R  e PM POSITION CONTROL    Using keys    and V  choose the required option and press the  OK  key to confirm it  The display shows the confirmed option and restores the menu GENERAL OPTIONS  The following options are available     BACK   Press key F1 to restore the menu PROFILE SETTING   e  MENU   Press key      to restore the MAIN MENU    9 15 Skate type setting by means of the Handset    See 8 6 16 for the meaning of this parameter   Using keys    and   run through the GENERAL OPTIONS and choose the SKATE TYPE Option  Press the  OK  key to confirm the choice   The following options are viewed on the display    e STD TYPE   e EXP TYPE      EXP B            Using keys 4 and    choose the required option and press the  OK  key to confirm it  The display shows the confirmed option and restores the menu GENERAL OPTIONS  The following options are available     BACK   Press key F1 to restore the menu PROFILE SETTING   e  MENU   Press key F3 to restore the MAIN MENU    9 16 Aux Input type setting by means of the Handset    See 8 6 17 for the meaning of this parameter   Using keys 4 and   run through the GENERAL OPTIONS and choose the AUX INPUT Option  Press the  OK  key to confirm the choice   The following options are viewed on the display    e DISABLE        PARTIAL REOPENING   Using keys 4 and    choose the required option and press the  OK  key to confirm it  The display shows the confirmed option and restores the menu GENERAL OPTIONS  The following options are available     B
52. RNING SOFTWARE  Reversing system             00 Monitor  Opening high speed MLC Test ND  cod  10 cod  01 Statistics  Opening low speed      i     Y  cod  11 0 signa  cod  02 Last Alarms  Opening comfort Y Y     MLC input alarm Alarm Counters  cod  03  Closing high speed  cod  13 y y  Kn Input     MLC Monitor  Closing low speed cod  04  cod  14 Y Y  Car Door Lock  Closing comfort cod  05 Warranty Data  cod  15  Glazed  amp  Heavy doors  cod  06  Reversing System force  cod  09 Aux Output Relay  cod  07  Reversing system  offset Y  Fire Fighting Option  cod  19  EOD Timeout  cod  20          SEMATIC    All rights reserved   Changes can be made without notice     25       a      e         gt                    o             o  5                         8   o   c   s  o       SEMATIC    All rights reserved     26    808 000 000 505   rel 3    Edition 18 December 2009   8 3 Self learning cycle activation by means of the handset   By using the handset to operate a self learning cycle  interferences with possible signals coming from the main lift con   troller are avoided   e Power the system   e Turn  ON  the door controller  if there        any closing or opening signals from the main lift controller  the operator  will perform the relevant reset cycle in low speed up to the end run limit   Connect the handset to RJ45 connector   If necessary  using keys    and   choose the required language and confirm with the    OK    key   Using keys    and    run through the MAIN MENU and cho
53. S EN ISO 9002 1994 _ N  0000 Registration number       FM 45455 EUROPEAN ELEVATOR ASSOCIATION G R    U P             
54. U   premendo il tasto F3 si ritorna al men   PRINCIPALE          LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    11 AGGIORNAMENTI DEL SOFTWARE DEL CONTROLLER    Collegare il tastierino al connettore RJ45    Utilizzando i tasti 4  e   posizionarsi sulla lingua desiderata e confermarla con il tasto  OK     Con i tasti 4 e W scorrere il MENU PRINCIPALE e posizionarsi su AGGIORNAMENTI    Premere  OK  per confermare la scelta    Sul display verranno visualizzati l aggiornamento disponibile e la versione software attualmente caricata    Con il tasto  OK  confermare l aggiornamento    Il controller si resetta e appare la scritta Upload e verr   visualizzata la progressione di caricamento dei dati    AI termine del caricamento il controller riprende il suo normale funzionamento    E comunque consigliabile effettuare un  RESET PARAMETRI DI FABBRICA  da men      IMPOSTAZIONE PROFILI  ed  eseguie un nuovo ciclo di AUTOAPPRENDIMENTO  verificando al termine il settaggio dei parametri     Nel caso la connessione del tastierino venga interrotta prima che l operazione sia terminata  spegnere il controller   OFF  e riaccenderlo  ON  e riconnettere il tastierino  riprender   dall inizio l aggiornamento del controller     12 MANUTENZIONE DELL OPERATORE  Almeno una volta l anno ripetere i controlli di seguito elencati     Pulizia delle porte  binari  soglie  cinghie  ecc   da polvere o detriti  da cui dipende un buon funzionamento mecca   nico delle porte    Controllare i co
55. UALE UTENTE        ELEVATOR PRODUCTS    EMC PROTECTION               DOOR OPENING RELAY Kc         I    DOOR CLOSING RELAY    OFFNUNGS RELAIS   I    SCHLIESS RELAIS  RELE  DI CHIUSURA    PNP N O    KEEP CLOSED   GESCHLOSSEN HALTEN   MANTENERE CHIUSO   OPENING LIMIT Lc CLOSING LIMIT  Liza T  RE AUF ENDKONTAKT T  RE ZU ENDKONTAKT  DETECTOR  LIMITE APERTURA LIMITE CHIUSURA  PHOTOCELL    RELE  DI APERTURA                  DOUBLE      RELAY  DOPPELTE TB RELAIS  RELE  DI DOPPIO TB    Kaux AUXILIARY RELAY  ZUSATS RELAIS  RELE  AUSILIARIO    FIREFIGHTING RELAY  FEUERWEHR RELAIS  RELE  DI FIREFIGHTING      E O D  ACTIVATION RELAY  E 0 D  AKTIVIERUNG RELAIS  RELE  DI ATTIVAZIONE E O D   ENCODER  DOOR CLOSING RELAY IN SLOW SPEED  SCHLIESS RELAIS NIEDRIGE GESCHWINDIGKEIT  RELE  DI CHIUSURA IN BASSA VELOCITA    PHOTOCELL              s dc   INSIDE  1 Battery            24V  IM     OPTIONAL   REVERSE MOTION RELAY  LEAD FREE 1   NI   r1 wa cm          REVERSIERUNGS RELAIS    RoHS Compliant  Directive 2002 95 EC    RELE  DI INVERSIONE DI MOTO    SELF LEARNING CYCLE BUTTON    PUSH AT INSTALLATION    TASTE F  R SELBSTLERNZYKLUS    BEI INSTALLATION DR  CKEN    TASTO PER CICLO DI AUTOAPPRENDIMENTO   PREMERE ALLA INSTALLAZIONE        SEMATIC    All rights reserved     E  2  2  5  2         8  8      E  8     5  8      8  2  8  o    MOTOR       COD  H147AAYX 1         sematic  LIFT       DOORS    808 000 000 505   rel 3    Edition 18 December 2009    4 3 Sematic Drive System  set up and incoming o
56. ULSIVA  e Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI     Sono disponibili le opzioni        IMPULSIVA  e Utilizzando i tasti 4 e V posizionarsi sulla opzione desiderata    confermarla con il tasto  OK   e  BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI    e    MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE          SEMATIC All rights reserved   Changes can be made without notice             L LI E T DOORS          SEMATIC    All rights reserved     a        e       5                   o             o  a             5        8   o   c   s  o    36    808 000 000 505   rel 3    Edition 18 December 2009  10 MENU MANUTENZIONE   DIAGNOSTICA E GESTIONE ALLARMI    10 1 Consultazione del men   Manutenzione con tastierino     Collegare il tastierino al connettore RJ45    e Utilizzando i tasti 4 e W posizionarsi sulla lingua desiderata e confermarla con il tasto    OK     e Coni tasti 4  e W scorrere il MENU PRINCIPALE e posizionarsi su MANUTENZIONE  e Premere      per confermare la scelta     Sul display verranno visualizzate le seguenti opzioni   e MONITOR     STATISTICHE  e ULTIMI ALLARMI  e CONTATORI ALLARMI  e MONITOR QUADRO DI MANOVRA     DATI DI GARANZIA       Sono disponibili le opzioni        BACK   premendo il tasto F1 si ritorna al men   MANUTENZIONE         MENU     premendo il tasto      si ritorna al MENU PRINCIPALE  e Utilizzando i tasti 4 e W scorrere il men   di MANUTENZIONE posizionandosi sull op
57. Utilizzando i tasti    e   scorrere il men   di INVERSIONE DI MOTO posizionandosi sull opzione  OFFSET DI  INVERSIONE DI MOTO    e Confermarla premendo il tasto OK     Nella parte destra del display viene visualizzata graficamente la percentuale attualmente impostata  utilizzando i tasti  A e V rispettivamente si diminuisce o si aumenta il valore visualizzato     LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    8 6 Profili di velocit   e regolazioni di alta velocit   con tastierino    Collegare il tastierino al connettore RJ45    Utilizzando i tasti 4 e   posizionarsi sulla lingua desiderata e confermarla con il tasto OK   Con i tasti 4 e    scorrere il MENU PRINCIPALE e posizionarsi su IMPOSTAZIONE PROFILI   Premere OK per confermare la scelta    Sul display verranno visualizzate le seguenti opzioni    e Impostazioni Rapide      Inversione di moto   e Impostazioni Avanzate      Reset Parametri di fabbrica   e Area riservata   Utilizzando i tasti 4 e   scorrere il men   di    Impostazione Profili    posizionandosi sull opzione IMPOSTAZIONI  RAPIDE   Confermarla premendo il tasto OK    Sono disponibili le opzioni        BACK   premendo il tasto F1 si ritorna al MENU PRINCIPALE    e    MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE     8 6 1 Opzione    Impostazioni Rapide      Questa opzione permette di modificare in maniera semplice e veloce i profili di velocit      Una volta scelta questa opzione come indicato all   inizio del paragrafo 8 5 v
58. V per selezionare il numero  Premere Ok per confermare la password inserita     8 9 6 Opzione  Salva Profilo   Questa opzione permette all utente di salvare il profilo di velocit   impostato tramite le opzioni  Impostazioni  Rapide  oppure  Impostazioni Avanzate         SEMATIC    All rights reserved   Changes can be made without notice     8 9 7 Opzione    Richiama Profilo     Questa opzione permette all utente di richiamare il profilo di velocit   salvato in precedenza  Se nessun profilo     stato memorizzato in precedenza viene richiamato il profilo di default           LIFT DOORS    808 000 000 508 rel 3    Edition 18 December 2009  8 9 8 Opzione    Download Dati     Questa opzione permette di trasferire i dati memorizzati relativi ai menu    Opzioni Generali    e    Impostazione  Profili    dal controller SDS rel  3 ad un tastierino SDS rel  3   Aspettare fino a quando appare il messaggio    Download OK    sul tastierino     8 9 9 Opzione    Up load Dati      Questa opzione permette di trasferire i dati precedentemente memorizzati sul tastierino SDS rel  3 ad un nuovo  controller SDS rel  3    Attivando l opzione    possibile scegliere se trasferire solo il profilo di velocit       Impostazione Profili     oppure  anche le impostazioni delle  Opzioni Generali   Utilizzare i tasti         per selezionare la modalit   desiderata e  confermare con OK     Nota  le opzioni di Download e Upload sono molto utili in caso si ritenga necessario trasferire le impostazioni  preferit
59. a        CONTROLLER  FUNZIONANTE             SEMATIC    All rights reserved   Changes can be made without notice      d       LIFT DOORS    808 000 000 SDS   rel 3     Edition 18 December 2009  La seguente tabella contiene i parametri disponibili per codice  la descrizione di queste e il range di  modifica consentito        Codice  Impostazion    Param      di default   Parametro Range Nota       00 00 Scelta modalit   inversione di moto 00  01    00   gt  Interna    01  gt  Esterna in movimento  02   gt  Esterna in movimento stazionamento       01 00 Test Quadro di Manovra 00  0         00   gt  In Movimento  01  gt  In Movimento Stazionamento       gt  Off   02 00 Mancanza Quadro di Manovra 00  01     00   gt  Stop Immediato    01  gt  Bassa velocit     stop   2   gt  Ciclo bassa velocit                                 03 00 Allarme Quadro di Manovra 00  04  00     Off   01    On  04 00 Ingresso Kn 00  0       00   gt  Default   01  gt  Apertura parziale   0   gt  Costola meccanica  05 00 Gancio di cabina 00  04  00     Off   01    On  06 00 Porte in vetro e porte pesanti 00  04 00     Off   01  gt  On  07 00 Utilizzo uscita rel   Aux 00  01       00   gt  Off    8 01  gt  Gong In Apertura    2   gt  Percentuale di spazio    8   gt  Segnale protezione termica  08 50 Percentuale spazio  Percentuale di quota di spazio 00  99 00  99     per il funzionamento del rel   AUX   00   spalla chiusura                                                                 09 6 Forza Inversion
60. a mantenga il comando di  chiusura porte Kc  per permettere la richiusura delle lame dello scivolo dell operatore durante il moto     6 15 3 PM activation Delay  Default 300 sec     Questo sottoparametro rappresenta il ritardo di ingresso nella fase di stazionamento a scivolo aperto dopo l e   vento di attivazione rappresentato dalla disabilitazione del comando di chiusura KC  Il sistema attende dunque  per un tempo pari al parametro prima di aprire gli scivoli e portarsi nella condizione di risparmio energetico     6 15 4 PM opening space  Default 90 mm   Questo dato rappresenta la quota di spazio raggiunta dallo scivolo quando    completamente aperto durante lo  stazionamento a scivolo aperto     LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    6 15 5 PM position error  Default 5 mm    Questo sottoparametro rappresenta la soglia di spazio  relativa al punto di stazionamento a scivolo aperto  rappresentato dal parametro PM ACTIVATION DELAY  entro la quale possono muoversi i pannelli  Quando  viene superato il valore impostato il controller perde il segnale di porta chiusa LC e attiva una chiusura auto   matica e immediata dello scivolo  Durante questa ultima operazione il quadro di manovra pu   comunque  comandare l apertura o la chiusura delle porte    6 15 6 PM position control  Default 00    Il sottoparametro consente la selezione di due differenti correnti applicabili al motore       00  Corrente di stazionamento nulla  In questa situazione c e  la po
61. al the use of the  Sematic E O D  Emergency Opening Device to  the Door controller       Handset  Optional     Auxiliary Contact Kaux          RJ45 connector     B     Connector pins  15 42       These connections require dry   voltage free  contacts   contact  open when inactive        Not yet implemented                   LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice     11       808 000 000 505   rel 3    Edition 18 December 2009    Note  Sematic Drive System   controller may be used also with incoming signal from the Main Lift Controller with vol   tage range between 6 and 24 Vdc        To use this feature     e Remove the shunt between 37 38 connector pins  e Connect the 38 connector pin at the OV DC external incoming signal Power supply       OUTGOING SIGNALS FROM THE DOOR CONTROLLER       Signal    Connector Pins    Contact Type  amp  Normal State    Notes       Opening limit switch contact La    Connector pins  16   17    These connections provide dry   voltage free  contact     The contact is open when the door is fully  open   Contact rating  3A 250Vac 30Vdc       Closing limit switch contact Lc    Connector pins  18   19    These connections provide dry   voltage free  contact     The contact is open when the door is fully clo   sed   Contact rating  3A 250Vac 30Vdc       Reversing system signal IM    Connector pins  1 4    Connector pins  2 4    These connections provide dry   voltage free  contact         contact normally cl
62. alue   e The following options are available    e  BACK   press key F1 to restore the Main Menu      F2 KEY  to open and close the door  to test the modified profile   e    DRAW     press key F3 to update the speed profile drawing    8 9 3 Option  Reversing System Space    This option allows the user to set the space in wich the door operates a reopening cycle  caused by an obstruc   tion between the doors noticed by the reversing system   Increasing the space the stopping before reopening  time increase and viceversa    Use keys    and W to modify the reversing system space value and press the  OK  key to confirm it    e The following options are available   e  BACK   press key F1 to restore the Main Menu  e    MENU     press key F3 to restore the Main Menu    8 9 4 Option  Serial Bus    This option allows the user to select the serial Bus Interface type   On the display the following options are viewed    e BUS OFF  Default    TEST   SEM BUS   RESERVED   SWS MASTER   SWS SLAVE    If necessary  using keys    and W choose the required option and confirm with the    OK    key     Note  for inclined lifts that use Sematic Wireless System  please choose  SWS MASTER  or    SWS SLAVE    con   sulting the 809 000 000 Sematic SWS user manual     8 9 5 Option  Change Password    This option allows the user to change access passwords  input the new password as follows    Select the desired code digit using keys  amp  and W  Use keys     and  gt  to move to different digits  Press OK a
63. ato  PORTE IN VETRO  e porte pesanti  Codice Param  06   6 7 Uscita Aux  Codice Param  07   6 7 1 Percentuale Spazio  6 7 2 Gong in apertura  6 7 3 Segnale protezione termica  6 8 Chiusura Forzata  Nudging   6 9 Fire Fighting  Codice Param  19   6 10 Doppio TB  6 11 Utilizzo EOD  Emergency Opening Device  e tempo di disattivazione  Codice Param  20   6 12 Logica Ingresso Kn  Codice Param  21   6 13 Rotazione motore in chiusura  Codice Param  22   6 14 Scelta motore  6 15 Scelta tipo di stazionamento in chiusura  Codice Param  25     6 15 1 Stazionamento a scivolo chiuso  6 15 2 Stazionamento a scivolo aperto  6 15 3 PM activation Delay   6 15 4 PM Opening space   6 15 5 PM position error          LIFT DOORS    10    14    17       SEMATIC    All rights reserved   Changes can be made without notice           SEMATIC    All rights reserved        a      e  c  5                o          o  5                        o  c  s  o    808 000 000 505   rel 3    Edition 18 December 2009    10    11  12  13    6 15 6 PM position control  6 16 Scelta del tipo di scivolo  Codice Param  26   6 17 Ingresso AUX  Codice Param  32   6 17 1 Disattivato  default   6 17 2   apertura parziale  6 18 Tipo di segnalazione inversione di moto  Codice Param  34   6 18 1 Impulsiva  6 18 2 Continua  default   6 18 3 Monostabile impulsiva  6 19 Allarmi    OPERAZIONI PRELIMINARI ALLA MESSA IN FUNZIONE  7 1 Ciclo di Autoapprendimento  7 2 Attivazione del ciclo di autoapprendimento con controller  senza l uti
64. ators e Ascensori panoramici  e Hospital elevators e Ascensori per ospedali  e Special executions e Esecuzioni speciali       SEMATIC    All rights reserved   Changes can be made without notice           LIFT DOORS    see www sematic com for latest release    808 000 000 505   rel 3    Edition 18 December 2009    Index    1    2    PREFACE    WHAT IS THE SEMATIC DRIVE SYSTEM   2 1 Speed profiles    GENERAL FEATURES   3 1 Technical information Sematic Drive System    DC PWM and AC VVVF Brushless    3 2 Sematic Drive System  Door Controller  DC PWM        AC VVVF Brushless    3 3 Technical information Sematic Drive System   Brushless Plus  AC VVVF Brushless Plus   3 4  Sematic Drive System  Brushless Plus Door Controller  AC VVVF Brushless Plus     SIGNALS TO FROM THE DOOR CONTROLLER   4 1  Sematic Drive System   DC PWM and AC VVVF Brushless  connections   4 2  Sematic Drive System   AC VVVF Brushless Plus  connections   4 3 Sematic Drive System  set up and incoming outgoing signals from the door controller   4 4  Detector Photocell Barriers  Signal Only Connection to the Door Controller  Direct Connection   4 5  Detector Photocell Barriers  Complete Connection to the Door Controller    INSTRUCTIONS WITHOUT HANDSET   Display in Automatic and Manual Mode   5 1 Automatic Mode  AUTO    5 2 Manual Mode  MAN    5 3 Programming Mode    PROG      5 4 Verify the correct working of the controller SDS    FUNCTIONS AVAILABLE  6 1 Reversing  6 1 1 Reversing System Force Setting  Param  Cod
65. cavi dell impianto    consigliato schermare i segnali Ka e  Kc  morsetti 3  5 e 15  con fili di messa a terra sui lati   e Modifiche nella lunghezza e nella disposizione dei cablaggi possono pregiudicare le caratteristiche EMC del sistema     4 4 Detector Fotocellule Barriere  collegamento di solo segnale al controller  collegamento diretto    Per questo collegamento    necessario un contatto esterno senza tensione di un rel    morsetti 15 23     E possibile collegare il solo segnale di uscita da fotocellula  o dispositivo analogo   costituito da contatto senza tensio   ne  in modo che il controller sia direttamente informato della necessit   di riapertura  La fotocellula  o il dispositivo ana   logo  ha quindi alimentazione indipendente e invia il solo segnale di uscita al controller del Sematic Drive System      La riapertura viene gestita secondo le impostazioni INVERSIONE DI MOTO  RIAPERTURA PARZIALE e LOGICA INGRES           6    In ati C  LIFT DOORS    SO Kn  vedere 8 6 2  6 3 e 6 12      808 000 000 505   rel 3    Edition 18 December 2009  Nota  questo tipo di collegamento non prevede l interazione tra il controller e le operazioni di Fire Fighting  Il quadro  di manovra generale deve fare in modo di interrompere il segnale proveniente dalle fotocellule barriera oppure deve  interromperne l alimentazione  come richiesto in modalit   Fire Fighting     4 5 Detector Fotocellule Barriere  collegamento completo al controller  Per collegamento completo si intende che il disp
66. cceleration  03  Acceleration C3  High Speed  04  High Speed C4  Offset Deceleration    5  Offset Deceleration C5  Deceleration  06  Deceleration C6  Deceleration Stop  07  Low Speed C7  Low Speed    a      e       5                   o             o  a                       8   o   c   s  o       SEMATIC    All rights reserved     2 sematic  LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009  8 9 1 Option    Opening Parameters     The following options are viewed on the display   e LOW START SPEED  ACCELERATION START  ACCELERATION  HIGH SPEED  OFFSET DECELERATION  DECELERATION  LOW SPEED  FITTINGS       For each of the above listed parameter the parameter name is displayed at the top  the current value is displayed  at the bottom with the relevant unit measure  the up down arrow keys allow changing the current value   e The following options are available    e  BACK   press key F1 to restore the Main Menu      F2 KEY  to open and close the door  to test the modified profile   e    DRAW     press key F3 to update the speed profile drawing    8 9 2 Option  Closing Parameters    The following options are viewed on the display   e LOW START SPEED   DECELERATION STOP   ACCELERATION   HIGH SPEED   OFFSET DECELERATION   DECELERATION   LOW SPEED   FITTINGS    For each of the above listed parameter the parameter name is displayed at the top  the current value is displayed  at the bottom with the relevant unit measure  the up down arrow keys allow changing the current v
67. conds     5  Switch OFF the controller and connect the motor and the encoder EE    6  Switch ON and verify the display lighting  EE  7  Press key 4 to enter in MAN mode  led MAN switch on   EN    8  Press key 2 and 3 to verify the partial motor movement  partial opening and closing move   ment      Note  In case of alarm or loss of movement try to connect another motor with encoder  only  the connection  do not replace it initially on the door and repeat from point 5 to point 8  If the  new motor works correctly replace the motor on the door        CONTROLLER  NOT DEFECTIVE             SEMATIC    All rights reserved   Changes can be made without notice           LIFT DOORS    808 000 000 SDS rel3  Edition 18 December 2009  The following table contains the available parameters  the relevant codes  the description and the allowed  modification range                                                                                                              Param   ces Default Parameter Range Note  00 00 Reversing system choice 00  01 0  00   gt  Internal  01  gt  External   Moving       gt  External   Moving   Parking  01 00 Main Lift Controller Test 00 01     00   gt  When Movingl  01  gt  Moving   Parking       gt  Off  02 00             signal  00  01        00   gt  Instant Stop  01  gt  Low Speed to Stop   2   gt  Low Speed Cycle  03 00 MLC Input Alarm 00  04 00     Off  01  gt  On  04 00 Kn Input 00 01     00   gt  Default  01  gt  Limited door reversal   2     Safety edg
68. curred alarms showing their code  the relevant  description and time of occurrence  day  hour  minute from the door controller start up   Using keys    and V  run  through the stored alarm list  The following options are available    e  BACK   Press key F1 to restore the menu MAINTENANCE   e  CANC   Press key F2 to cancel all stored alarms   e  MENU   Press key F3 to restore the MAIN MENU    If the option ALARMS COUNTERS the display views the alarm list showing their code  the relevant description and the  number of times they have occurred  Using keys 4  and     run through the stored alarm list    The following options are available    e  BACK   Press key F1 to restore the menu MAINTENANCE   e  CANC   Press key F2 to cancel all stored alarms       MENU   Press key F3 to restore the MAIN MENU    The viewed alarms are the same as in the Alarms Table in 8 6 16     If the option MAIN LIFT CONTROLLER MONITOR is chosen  the system IS BACK TO FOLLOW MAIN LIFT CONTROL     LER S SIGNALS  the display shows a complete list of the input output signals with their value   When the input or output signal is activated the character on the display will change their graphic in white with dark    background    The following options are available    e  BACK   Press key F1 to restore the menu MAINTENANCE      MENU   Press key F3 to restore the MAIN MENU    If the option WARRANTY is chosen  the display shows       warranty expiration date   e the activity hours left before warranty expiration   
69. d     34    808 000 000 505   rel 3    Edition 18 December 2009  9 13 Motor type by means of the Handset    See 8 6 14 for the meaning of this parameter   Using keys    and    run through the GENERAL OPTIONS and choose the MOTOR Option   Press the            key to confirm the choice   For Sematic Drive System DC PWM    cod  B157AAEX01    controller the following motor list is displayed  these motors  are automatically recognized      m  B105AAAX01  B105AAAX02  B105AANX       B105AALX    AUTO       Using keys 4 and   is possibile to manually chose the following motor types     DC PWM B105AAAXO01     DC PWM B105AAAX02     DC PWM B105AANX     DC PWM B105AALX     DC PWM B105AAKX     DC PWM S40 V     DC PWM 530 V    For Sematic Drive System BRUSHLESS  cod  B157AAEX03    controller the default set motor is viewed on the display     Using keys 4 and    it is possible to manually chose the following motor types     Brushless B105AAJX    Brushless B105AAIX    Brushless B105AAHX    For Sematic Drive System BRUSHLESS PLUS  cod  B157AAEXO05  controller is available only with the B105AAGX motor     9 14 Closed parking Mode by means of the Handset    See 8 6 15 for the meaning of this parameter  Using keys    and   run through the GENERAL OPTIONS and choose the CLOSING PARKING MODE Option  Press the  OK  key to confirm the choice  The following options are viewed on the display      OPENED SKATE PARKING  e CLOSED SKATE PARKING  e PM ACTIVATION DELAY  e PM OPENING SPACE  e PM POSITION ERRO
70. d  03 Opening deceleration    Closing Cycle        Closing acceleration  C2 Closing hight speed  C3 Closing deceleration                                                                                              8     OPENING 4  CLOSING Y KEY  V  m s  Door opening  Door closing    gt  Open limit  MAX   lt   gt     1 1 m s Close limit  o A    Closing cyce      2 p Active reversing system         s  Opening cycle  a          o o                             A  t s  Warning  for big size doors   gt   for example total moving  Ka mass over 400       it s advisa   ble not to modify the pre set  Kc closing high speed factory  default  according to EN81  is standard  closing kinetic  energy limitations    Lc                         um     LIFT DOORS          SEMATIC    All rights reserved   Changes can be made without notice        808 000 000 505   rel 3    Edition 18 December 2009  3  GENERAL FEATURES    3 1 Technical information Sematic Drive System   DC PWM and AC VVVF Brushless        MAIN SUPPLY VOLTAGE 90 290 Vac  115 V 20   230V 26    50 60 Hz  TYPICAL POWER CONSUMPTION 200 VA   PEAK POWER CONSUMPTION 300 VA   MOTOR OVERLOAD PROTECTION  In   15 minutes     2I    3 minutes    OPERATIONAL TEMPERATURE RANGE from  10  C to  60  C    HUMIDITY non condensing between 20  and 80   PROTECTION rapid cartridge fuse  5x20  4 A    battery fuse  5x20  8 A   PERFORMANCE SPEED separately adjustable for opening and closing  REVERSAL SENSITIVITY Variable  only operational on door closing cyc
71. d closing commands have no  common contacts between the two doors   Shielded  Grounded Wire  Recommended    Highly       Forced closing control at  low speed Kb    Connector pins  15   22    These connections require dry   voltage free  contacts   contact open when inactive     The main lift controller may signal the forced  closing when the photocell  or similar device   shall be made inoperative due to a failure  or  after several door closing failures        Re Opening control Kn    Connector pins  15   23    These connections require dry   voltage free  contacts   both  logics available     See sections 4 1 1  amp  4 1 2  for the connection  to the door controller       Fire Fighting Contact Kff    Connector pins  15   39    These connections require dry   voltage free  contacts   contact  open when inactive     See section 6 9       Contact K2TB    Connector pins  15 41    These connections require dry   voltage free  contacts    contact open when inactive     This signal allows the door controller to reco   gnize different door opening widths in the  same lift installation    Given this signal  the opening and closing  operations are carried out referring to an  alternative TB  door width recorded by an  additional self learning cycle         Encoder Signals    Contact KEOD    Connector RJ45   A     Connector pins  15   40    Factory prewired  connector    These connections require dry   voltage free  contacts   contact  open when inactive     This connection is to sign
72. del display  Confermare il valore desiderato con la scritta  OK    display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI   Sono disponibili le opzioni   e  BACK   premendo il tasto F1 si ritorna al men   IMPOSTAZIONE PROFILI   e  MENU   premendo il tasto F3 si ritorna al MENU PRINCIPALE      9 Impostazione dell attivazione opzione Fire Fighting con tastierino  Per il significato di questo parametro vedere il    6 9  Utilizzando i tasti 4 e   scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione OPZIONI FIRE  FIGHTING   Confermarla premendo il tasto  OK    Sul Display verranno visualizzate le seguenti opzioni      Sensibilit   inversione di moto disattivata  INVER  DI MOTO OFF       Sensibilit   inversione di moto ridotta  SENSIBILITA I M  RIDOTTA    Utilizzando i tasti 4 e   posizionarsi sulla opzione desiderata e confermarla con il tasto  OK    Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI   Sono disponibili le opzioni   e  BACK   premendo il tasto F1 si ritorna al men   IMPOSTAZIONE PROFILI   e    MENU     premendo il tasto      si ritorna al MENU PRINCIPALE      10 Impostazione dell attivazione Timeout EOD con tastierino  Per il significato di questo parametro vedere il 8 6 11  Utilizzando i tasti 4 e W scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione TIMEOUT EOD   Confermarla premendo il tasto             Utilizzando i tasti 4 e V selezionare il valore del tempo desiderato in m
73. dere il 8 6 4  e Utilizzando i tasti      W scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione INGRESSO KN      Confermarla premendo il tasto  OK       Sul Display verranno visualizzate le seguenti opzioni      TIPO DEFAULT   e APERTURA PARZIALE      COSTOLA MECCANICA   e Utilizzando i tasti         posizionarsi sulla opzione desiderata e confermarla con il tasto  OK    e Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI      Sono disponibili le opzioni   e  BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI   e    MENU     premendo il tasto      si ritorna al MENU PRINCIPALE     9 3 Impostazione dell attivazione del Test QUADRO DI MANOVRA con tastierino    Peril significato di questo parametro vedere il 8 6 3  e Utilizzando i tasti 4 e W scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione TEST QUAD  MANOV      Confermarla premendo il tasto  OK      Sul Display verranno visualizzate le seguenti opzioni   e IN MOVIMENTO  e IN MOVIMENTO  STAZIONAMENTO  e OFF  e Utilizzando i tasti 4 e W posizionarsi sulla opzione desiderata    confermarla con il tasto  OK   e Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI      Sono disponibili le opzioni       BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI  e    MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE    um     LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notic
74. doors storage at temperatures ranging  between  10 and  60   C out of direct sunlight  and correctly installed    e guarantees the perfect performance of the products installed in environments with temperatures between  10 and   60   C and with a non condensing  relative humidity level included between 20  and 80     Special note  for temperatures and humidity rates outside these ranges  please consult our Technical Dept      The present document has been drafted in accordance with the following EU Directives   98 37 CE Machinery Directive and subsequent modifications  when applicable   95 16 CEE Lifts Directive   93 68 CEE Markings   90 269 CEE Heavy loads handling   Noise  Acoustic emission  86 188 CEE modified according to Directive 98 24 CEE  Electromagnetic compatibility 89 336 CEE    and with the following particular standards   EN81        AS1735        EN12015 EN12016        EN13015        ASME A17 1  2000        UL508C             5 for motors       B105AAAXO1   1 Nm Dc  B105AABXO1   1Nm Dc sur demande   B105AAAX02   2Nm Dc  B105AABX02   2Nm Dc sur demande   B105AALX   Dc   GR63x55 SG120   B105AANX   Dc   GR63x25 SG80K   B105AAPX   IP54   DC GR63x25 SG80K   B105AAQX   IP54   DC GR63x55 SG120K   B105AAIX   Brushless   BG62x30 SG80K   B105AAJX   Brushless   BG62x60 SG120   B105AAHX   Brushless   BG62x60 PLG60   B105AAGX   Brushless   B105AATX   IP54 Brushless BG62x30 SG80K   B105AARX   IP54 Brushless BG62x60 SG120K   B105AADX   Dc          gt  only for motors    e  B10
75. e                    2  5  3             8  S  E  ES             8      8      s  o       SEMATIC    All rights reserved     32    808 000 000 505   rel 3    Edition 18 December 2009  9 4 Impostazione dell attivazione Mancanza QUADRO DI MANOVRA con tastierino  e Per il significato di questo parametro vedere il 8 6 3 3  e Utilizzando i tasti 4 e    scorrere il men   di OPZIONI GENERALI posizionandosi sull   opzione MANCANZA QUAD                 e Confermarla premendo il tasto                Sul Display verranno visualizzate le seguenti opzioni   e STOP IMMEDIATO      BASSA VELOCITA   STOP   e CICLO BASSA VELOCIT    e Utilizzando i tasti 4 e    posizionarsi sulla opzione desiderata    confermarla con il tasto  OK    e Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI      Sono disponibili le opzioni   e  BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI   e    MENU     premendo il tasto      si ritorna al MENU PRINCIPALE     9 5 Impostazione dell attivazione dell  Allarme QUADRO DI MANOVRA con tastierino    Peril significato di questo parametro vedere il 8 6 3 4  Questa impostazione permette di attivare o disattivare l allarme che segnala l assenza del segnale di comando prove   niente dal quadro di manovra Le operazioni per la disattivazione o l attivazione del Allarme Q M  sono le seguenti   e Utilizzando i tasti 4 e V scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione ALLARME QUAD  MANOV   e Confermarla premend
76. e  05 00 Car door locking device 00  01 00     Off  01    On  06 00 Glass doors and heavy doors 00  04 00     Off  01  gt  On  07 00 Aux Output Relay 00  01       00   gt  Off  m 01  gt  Gong While opening       gt  Space percentage   B   gt  Termic Alarm signal  08 50 Space Percentage  Percentage of the available space       oo 00  99   00   closing limit   to operate the AUX relay   09 6 Reversing force setting 00  99 10 150 N  10 135 N U S  version   10 50 Opening High Speed 01 9  11 50 Opening Low Speed 01 99  12 80 Opening    comfort 01 9  13 40 Closing High Speed 01 9  14 3 Closing Low Speed 01 99  15 90 Closing  comfort  01 99  16   Not Used    17   Not Used    18   Not Used     19 01 Fire Fighting Mode 00  01 00   gt  Reversing system OFF  01  gt  Reversing System reduced sensitivity  20 01 Timeout EOD 0   gt  6 Opening time on EOD contact  minutes  minutes   21 00 Protective Device Logic Kn 00  01 00   gt  N O  on obstruction closed  01  gt  N C  on obstruction open  22 00 Closing Rotation 00  01 00   gt  Clockwise  01  gt  Anti clockwise  23      Partial reopening 01 9  24 u Not Used    25 00 Closed parking mode 00  01 00   gt  Closed skate parking  01  gt  Opened skate parking  26 00 Skate          00  0       00   gt  Standard  STD  skate    01    Expansion  EXP  skate  28 0   gt  Expansion  EXP B  skate  5 5 29   Not Used    si 32 00 Aux In 00  01 00   gt  Off       01  gt    Partial reopening  See Param  codes 23   E 8 34 00 IM signal type 00  0    00   gt  IM p
77. e 09   6 1 2 Reversing system offset  6 2 Reversing System choice  INTERNAL or EXTERNAL  Param  Code 00   6 3 Main Lift Controller Test  6 3 1 Main Lift Controller Test  When moving   Default setting   6 3 2 Main Lift Controller Test  When moving   Parking   6 3 3 No MLC Signal  6 3 3 1 Instant Stop  6 3 3 2 Low Speed to Stop  6 3 3 3 Low Speed Cycle  6 3 4 Main Lift Controller Input Alarm  Param  Code 03   6 4 Kn Input  Param  Code 04   6 4 1 Default type  6 4 2 Limited door reversal  6 4 2 Safety edge  6 5        Door Locking Device  USA   Restrictor   Param  Code 05   6 6 Full or Framed Glazed and Heavy Paneled Doors  GLASS AND HEAVY DOORS   Param  Code 06   6 7 Aux Output Relay  Param  Code 07   6 7 1 Space Percentage  6 7 2 Gong While Opening  6 7 3 Thermic alarm signal  6 8 Forced Closing  Nudging   6 9 Fire Fighting  Param  Code 19   6 10 Double TB  6 11 EOD  Emergency Opening Device  and timeout  Param  Code 20   6 12 Protective Device Logic Kn  Param  Code 21   6 13 Motor Rotation During Closing  Param  Code 22   6 14 Motor Type  6 15 Closing parking Mode  Param  Code 25   6 15 1 Closed skate parking  6 15 2 Opened skate parking  6 15 3 PM activation Delay  6 15 4 PM Opening space  6 15 5 PM position error          LIFT DOORS    pag     pag     pag     pag     pag     pag     10    14    17       SEMATIC    All rights reserved   Changes can be made without notice           SEMATIC    All rights reserved        a        e       5                   o                   
78. e Press contemporaneously Key 1 and Key 4 for few seconds to enter the programming mode  The display on the Door  Controller will show    P    and    00    flashing alternately    e When the Door Controller is in the programming mode  all signals coming from the main lift controller and from the  external devices  barriers  photocells      are ignored    e The parameter to be modified is selected by means of the increasing and decreasing KEYs  respectively the buttons  2 and 3  this parameter is then confirmed by pushing the key 1  ENTER    e After confirming the parameter to be modified  the display shows the relevant numeric value    e Modify the chosen parameter using the key 2  increase  and 3  decrease  and confirm the changes by pressing key 1  ENTER    e At the end of the necessary configurations  using the key 4 press to select the required operating mode  manual     MAN  or automatic    AUTO       sematic  LIFT D O O R S    808 000 000 505   rel 3    Edition 18 December 2009  5 4 Verify the correct working of the controller SDS    In order to verify if the controller is broken or not please follow the instruction below           INSTRUCTION CHECK    1  Remove all the connections to the controller including the power supply   2  Verify the controller power supply fuse   Note  Eventually replace the fuse     3  Connect only the power supply cable        4  Verify  that after switching ON the controller by the key ON  the controller disply will light          after 5 se
79. e di Moto 00  99 10 150     10 135 N ver  U S A    10 50 Alta Velocit   Apertura 01 99  11 5 Bassa Velocit   Apertura 01 9  12 80    Comfort    Apertura 01 9  13 40 Alta Velocit   Chiusura 01 9  14 x Bassa Velocita Chiusura 01 99  15 90    Comfort    Chiusura 01 99  16    non utilizzato    17 E non utilizzato    18   non utilizzato    19 01 Modalit   Fire Fighting 00  01 00     Inversione di moto OFF  01  gt  Sensibilit   inversione di moto ridotta  20 01 Tempo di disattivazione EOD 0   gt  6 Tempo di apertura contatto EOD  minuti  minuti   21 00 Logica dell ingresso Kn 00  01 00   gt  Normalmente aperto  si chiude all ostru   zione della fotocellula barriera  01  gt  Normalmente chiuso  si apre all ostruzio   ne della fotocellula barriera  22 00 Rotazione Chiusura 00  01 00   gt  Senso Orario  01  gt  Senso Antiorario  23      di apertura parziale 01 9  24   non utilizzato    25 00 Tipo di stazionamento chiusura 00  01 00   gt  Scivolo chiuso  01  gt  Scivolo aperto  26 00 Tipo scivolo 00  01 00   gt  Scivolo Standard  STD   a8 01    Scivolo Espansione  EXP   29  2   gt  Scivolo Espansione  EXP B   8    29   non utilizzato          8 32 00 Ingresso AUX 0 0 0   00   gt  Off  28 01  gt    apertura parziale  vedi Codice Param  23   E  5 34 00 Tipo segnalazione inversione di moto 00  01     00   gt  Impulsiva  aS 01  gt  Continua     5  2     Monostabile impulsiva                         x sematic  LIFT DOORS    808 000 000 505   rel 3     Edition 18 December 2009  6 DESCRIZIONE
80. e door movement  the signal is stored by the Door Controller which will complete the  required movement even if the main lift controller signal fails  The impulse width must be at least 400ms in duration   When the MAIN LIFT CONTROLLER TEST is set to  WHEN MOVING     default setting  or set to  MOVING   PARKING    the operation is as described in the next two sections     6 3 1 Main Lift Controller Test  when moving   default setting    When this parameter is set to    WHEN MOVING     the Door Controller checks for the Ka or Kc signal coming from  the main lift controller only during the door movement  Ka signal during the opening cycle  Kc signal during the  closing cycle   At the end of the movement  which can be detected through the La and Lc signals  respectively  Door Open and Door Closed  it is possible to remove the signal that has controlled the movement  without the  Door Controller detecting this as failure    For this setting  the main lift controller must be equipped with 2 relays  1 for the opening command  and 1 for  the closing command    The Door Controller checks for continuous presence of the Ka and Kc signals coming from the main lift control   ler     The Door Controller detects signal drops exceeding 200ms  this is interpreted as NO MLC SIGNAL alarm if the  relevant parameter MAIN LIFT CONTROLLER TEST is set on  WHEN MOVING      In case of signal failure  the Door Controller acts as described in the parameter setting             SIGNAL  see 8  6 4 3      
81. e open     7 sematic  LIFT DOORS    a               Ss  88  PES  PE       D gt                   lt            58  25  Ea  x    2 8  oS  Os  5    808 000 000 505   rel 3    Edition 18 December 2009  The photocell  or similar device  has therefore an independent power supply and sends only its outgoing signal to the    Sematic Drive System   controller   Reopening is operated according to the REVERSING SYSTEM  LIMITED DOOR REVERSAL EFFECT and PROTECTIVE DEVI     CE LOGIC settings  see sections 6 2  6 3 and 6 12      NOTE  This connection method does not provide for Door Controller interaction with Fire Service Operation  The Main  Lift Controller must be arranged to either interrupt the signal from the Detector Photocell Barrier  or to interrupt the  power supply of the Detector Photocell Barrier as required under Fire Service Operation  Fire Fighting         4 5 Detector Photocell Barriers  Complete Connection to the Door Controller  Complete Connection means that the device draws its power supply from and sends the re open signal directly and only    to the Sematic Drive System   controller   It is possible to have the complete connection of detectors or photocells with a 24 Vdc max 100 mA supply and a PNP    N O or N C output  through the connector pins                                                     GND END 33 GND ground connector pin  OUT PNP N O   N C           32                        N C signal from  detector photocell barrier  NC  24 Vdc IN GND  30  41 U ao  33 3
82. e prestazioni del dispositivo stesso   00   gt  Off  senza gancio di cabina    01   gt  On  con gancio di cabina     6 6 Porte con pannelli in vetro totale  vetro intelaiato  PORTE IN VETRO  e porte pesanti  Codice Param  06   L opzione ante vetro    da considerare quale complemento per la conformit   alla Norma EN81 1 2 al punto 7 2 3 6 d e  8 6 7 5 d   essa limita l alta velocit   d apertura della porta  limitandone il parametro relativo    Nota  Selezionare questa opzione anche in caso di porte pesanti    00   gt  Off  funzione disabilitata    01   gt  On  funzione abilitata     6 7 Uscita AUX  Codice Param  07   Questa opzione pu   essere utilizzata per segnalare il raggiungimento di una particolare quota di spazio  programmabi   le  o come Gong in apertura  dispositivo gong non fornito da Sematic      Nota  impostazione di default  00   gt  off  6 7 1 Percentuale spazio    Questa opzione quando settata implica che l uscita AUX emetta un segnale durante l apertura da una certa per   centuale di spazio  relativa all apertura totale della porta  e un segnale durante la chiusura fino alla stessa per     centuale di spazio prima citata   LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    6 7 2 Gong in Apertura  Questa opzione quando settata implica che l uscita AUX emetta un segnale durante l apertura  dispositivo gong    non fornito da Sematic      6 7 3 Segnale protezione termica  Questa opzione quando settata implica che l uscita AUX emetta un segnale qua
83. e su pi   impianti controller ed inoltre permettono di salvare su PC i dati per poterli riutilizzare in caso di  sostituzione del controller    Per salvare i dati del profile di un impianto su PC occorre dotarsi dell apposito kit composto dal cavo E066AAYX  e dal software Sematic SDS  Updater   PC Datamanager     E066AAYX ica    Software  Updater  Tia           Sematic SDS  Updater   PC Datamanager             Fw             es dan 192254  Cotes        UN       8 9 10 Opzione  Riaperture dolci   Attivando questo parametro  01   il controller BHV ad ogni successiva riapertura imposta un profilo di velocit      pi   basso    e Collegare il tastierino al connettore RJ45    e Utilizzando i tasti 4 e W posizionarsi sulla lingua desiderata e confermarla con il tasto OK   e Coni tasti 4  e W scorrere il MENU PRINCIPALE e posizionarsi su IMPOSTAZIONE PROFILI      Premere      per confermare la scelta    e Sul display verranno visualizzate le seguenti opzioni     e IMPOSTAZIONI RAPIDE  e FORZA DI INVERSIONE DI MOTO  e IMPOSTAZIONI AVANZATE     RESET PARAMETRI DI FABBRICA     AREA RISERVATA  e Utilizzando i tasti    e   scorrere il men   di IMPOSTAZIONE PROFILI posizionandosi sull opzione  IMPOSTAZIONI AVANZATE   e Confermarla premendo il tasto OK   Dopo la conferma della scelta tramite il tasto OK verr   richiesto dal display di inserire una password di  cinque cifre  La password impostata in fabbrica come default    00001   Per inserire le cifre utilizzare i tasti     e    per selezi
84. e the software version in use   e the motor code in use   The following options are available    e  BACK   Press key F1 to restore the menu MAINTENANCE  e  MENU   Press key      to restore the MAIN MENU          LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009  11 CONTROLLER SOFTWARE UPGRADE    Connect the handset to the RJ45 connector   If necessary  using keys    and   choose the required language and confirm with the    OK    key   Using keys 4 and    run through the MAIN MENU and choose  UPDATE    Press  OK  to confirm the choice   Display shows the last available update and the software version in use at the moment    Press  OK  to confirm the software update   Controller operates a reset and the display shows  Upload  with the progression value of data loading  At the end of the upload the controller operates a reset   It is anyway advisable to SET FACTORY DEFAULT from the PROFILE SETTINGS menu and to run a new  SELF LEARNING CYCLE  checking the parameter settings       In case of interruption of connection between handset and controller during the data transfer  turn  OFF  the  controller  turn it  ON  again and reconnect the handset  The upload starts again from the beginning    12 DOOR OPERATOR MAINTENANCE   At least once a year complete the following checks    e Clean the doors  tracks  bottom tracks  belts etc   from dust or debris as this maintains the door good mechanical  operation      Check the electric connections and their fitting to the con
85. end door open door close signals           LIFT DOORS          SEMATIC    All rights reserved   Changes can be made without notice     23          SEMATIC    All rights reserved     a  2  e  2  5                8            2  a          8      8                      24    808 000 000 505   rel 3    Edition 18 December 2009  8 INSTRUCTIONS WITH THE HANDSET    8 1 Handset  optional     Optional Kit   cod    147               Recommendation    Although the handset  see picture 1  can be directly connected by the installer main   tenance personnel to the door controller on the car s roof  the ideal situation is to have  a connection with the door controller inside the car  see picture 2     In this way the installer maintenance personnel can work in absolutely safe conditions  and can control the movement of the coupled doors during their effective operational  mode    To make this connection  ask Sematic for the appropriate adapter cod  B147AABX  see  picture 3   a 16 mm  diameter hole is required in any chosen position within the Car  walls      Note  when the handset is connected to the controller the display shows the warran   tly expiration date  2 years from the manufacturer date  and the activity hours left  before warrantly expiration  Subsequently choose the language by means of the keys  V and    and confirm the choice through the  OK  key     Important note  when the handset is connected  all the signals from the main lift  controller  but not the K2TB  if used  and K
86. ente aperto   35   36  Motore morsetti Connettore precablato in fabbrica  43 44 45  Allarme acustico  BUZZER  morsetti Questi collegamenti mettono a   opzionale  15 21 disposizione un contatto 24Vdc     100mA  Il contatto    normalmen   te aperto              e Per quanto riguarda  Manutenzione porte Sematic      l installazione meccanica degli    operatori    fare riferimento al    manuale  Installazione e    e Il controller    fornito gi   montato sull operatore  I collegamenti tra controller e motore vengono realizzati in fabbri   ca  I cavi di connessione sono fissati con fascette alla traversa per prevenire possibili danneggiamenti dovuti al con   tatto con la cinghia di trasmissione  come mostrato nell immagine seguente  per motori B105AAIX  B105AAJX   B105AAKX  B105AANX e B105AALX                              A  AN                                    nne                02226556        psss                                                                                                           L BOR                                           B                                                 990992                                                                                                                                           Nota  In caso di sostituzione del motore    del controller  assicurarsi di fissare i cavi come sopra descritto  per  evitare il contatto dei cavi con la cinghia di trasmissione     e Attenzione  per evitare eventuali fenomeni d induzione sui 
87. enu GENERAL OPTIONS    e The following options are available   LIFT DOORS       BACK     Press key Fi to restore the menu PROFILE SETTING     MENU     Press key F3 to restore the MAIN MENU    9 9 Fire Fighting Option setting by means of the Handset  See 8 6 9 for the meaning of this parameter   Using keys 4 and V  run through the GENERAL OPTIONS and choose the FIRE FIGHTING OPTION  Press the  OK  key to confirm the choice   The following options are viewed on the display     REVERSING SYSTEM OFF  REVERSING SYSTEM SENSIBILITY REDUCED    808 000 000 505   rel 3    Edition 18 December 2009    Using keys    and    choose the required option and press the  OK  key to confirm it  The display shows the confirmed option and restores the menu GENERAL OPTIONS  The following options are available      BACK   Press key F1 to restore the menu PROFILE SETTING   MENU   Press key F3 to restore the MAIN MENU    9 10 EOD Timeout setting by means of the Handset  See 8 6 11 for the meaning of this parameter   Using keys    and V  run through the GENERAL OPTIONS and choose the EOD TIMEOUT Option  Press the  OK  key to confirm the choice   Using keys    and V  choose the desired time value in minutes  Press the  OK  key to confirm the choice   The display shows the confirmed option and restores the menu GENERAL OPTIONS   The following options are available      BACK   Press key F1 to restore the menu PROFILE SETTING    MENU   Press key      to restore the MAIN MENU    9 11  Protective Device Logic
88. erranno visualizzati dal display   PARAMETRI APERTURA    Un grafico che rappresenta il profilo di velocit   del ciclo considerato  apertura    chiusura     In alto a sinistra vi    indicato un numero che indica la percentuale di velocit   utilizzata  Utilizzare i tasti 4 e  V del tastierino per modificare tale parametro    In basso a sinistra vi    indicato un numero che indica l effettiva velocit   impostata in m s    In basso a sinistra vi    indicato un numero che indica il tempo  T   in secondi impigato per effettuare la aper   tura    Utilizzando i tasti 4 e   rispettivamente si aumenta o si diminuisce il valore della velocit      e Utilizzando i tasti     e    rispettivamente si cambiano il parametro da impostare  che possono essere  ALTA  VELOCIT      BASSA VELOCIT      COMFORT  visualizzati in alto a sinistra    e    parametro  Comfort  determina il valore delle accelerazioni o decelerazioni che il controller deve rispetta   re nell applicare i cambiamenti di velocit   imposti dal profilo  Questo parametro    importante nel determina   re la fluidit   del movimento delle ante       centro viene visualizzato il parametro espresso in percentuale     sotto il valore reale del parametro    e Terminata la modifica dei parametri il grafico si adeguer   alle modifiche fatte mostrando il profilo di velocit    ottenuto    e Premendo il tasto F2   lt  gt     gt  lt   si pu   verificare il funzionamento delle porte con il profilo impostato e  effet   tuando una apertura  si aggi
89. es the time  T   in seconds required to perform the  opening cycle   Using keys    and       the value of the speed parameter is respectively increased or decreased       Using keys     and     it is possible to change the parameter to be set  the parameters which are available  are  HIGH SPEED    LOW SPEED    COMFORT     e The parameter  Comfort  determines acceleration value or deceleration value that the controller has to  comply with while changing profile velocity  This parameter is important to establish the panel fluidness  movement  The display shows the parameter value expressed in percentage and below the real value of the  parameter    At the end of the parameters modifications the diagram will adapt and will show the new speed profile   Press key F2               to check the door operation with the new set profile and  by performing an ope   ning cycle  this will update the indicator of time necessary to carry out the opening cycle with the new set  profile    e Press key       NEXT  to carry on the profile setting with the CLOSING PARAMETERS setting  the same ope   rations must be followed as above in relation to the OPENING PARAMETERS setting    e Press key Fi  BACK  to the previous menu     8 7 Option  Set Factory Default    Choose this option to reset the movement parameter to the factory default values    Connect the handset to RJ45 connector   If necessary  using keys    and    choose the required language and confirm with the  OK  ke  Using keys    and    
90. esanti con tastierino  9 8 Impostazione dell uscita Aux con tastierino   9 9 Impostazione dell attivazione opzione Fire Fighting con tastierino   9 10 Impostazione dell attivazione Timeout EOD con tastierino   9 11 Impostazione dell attivazione della Logica Ingresso Kn con tastierino   9 12 Impostazione dell attivazione della Rotazione Chiusura con tastierino   9 13 Impostazione dell attivazione della Scelta Motore con tastierino   9 14 Impostazione dell attivazione del Tipo di Stazionamento in chiusura con tastierino  9 15 Impostazione del tipo di scivolo con tastierino   9 16 Impostazione dell ingresso AUX con tastierino   9 17 Impostazione del tipo di segnalazione inversione di moto con tastierino    MENU    MANUTENZIONE   DIAGNOSTICA E GESTIONE ALLARMI  10 1 Consultazione del Men   Manutenzione con tastierino    AGGIORNAMENTI DEL SOFWARE DEL CONTROLLER  MANUTENZIONE DELL OPERATORE  RICAMBI          LIFT DOORS    pag     pag     pag     pag     pag   pag   pag     23    24    31    36    37  37  37    1    808 000 000 505  rel 3     Edition 18 December 2009  PREMESSA    La stesura di questo manuale    stata realizzata considerando che la Societ   che si fa carico dell installazione dei pro   dotti Sematic risponda ai seguenti requisiti essenziali     le persone addette alla installazione e o manutenzione delle porte devono essere a conoscenza delle norme Generali  e Particolari vigenti in materia di sicurezza ed igiene del lavoro  89 391 CEE   89 654 CEE   89 656          
91. ese parameter meanings and settings are detailed in the following paragraphs     9 1 Reversing System Setting by means of the Handset  e See 8 6 1 for the meaning of this parameter  e Using keys           amp  run through the GENERAL OPTIONS and choose the option REVERSING SYSTEM  e Press the    OK    key to confirm the choice  e The following options are viewed on the display    e INTERNAL      EXTERNAL MOVING      EXTERNAL MOVING PARKING  e Using keys    and   choose the required option and press the            key to confirm it  e The display shows the confirmed option and restores the menu GENERAL OPTIONS  e The following options are available        BACK   Press key F1 to restore the menu GENERAL OPTIONS   e  MENU   Press key F3 to restore the MAIN MENU    9 2 Kn Input Activation by means of the Handset  e See 8 6 4 for the meaning of this parameter  e Using keys 4 and    run through the GENERAL OPTIONS and choose the option KN INPUT  e Press the  OK  key to confirm the choice  e The following options are viewed on the display    e DEFAULT TYPE   e LIMITED DOOR REVERSAL   e SAFETY EDGE  e Using keys    and   choose the required option and press the  OK  key to confirm it  e The display shows the confirmed option and restores the menu GENERAL OPTIONS  e The following options are available        BACK   Press key F1 to restore the menu GENERAL OPTIONS   e  MENU   Press key      to restore the MAIN MENU    9 3 Activation of the Main Lift Controller Test by means of the Hand
92. eys    and V  run through the    General options  and choose the option Glazed Paneled and Heavy Doors  e Press key  OK  to confirm the choice  e The following options are viewed on the display   e OFF  e ON  e Using keys 4 and     choose the required option and press the  OK  key to confirm it  e The display shows the confirmed option and restores the menu    General Options   e The following options are available       BACK   Press key F1 to restore the menu GENERAL OPTIONS      MENU   Press key      to restore the MAIN MENU    9 8  AUX Output Relay setting by means of the Handset  See 8 6 7 for the meaning of this parameter  Using keys    and    run through the GENERAL OPTIONS and choose the option AUX OUTPUT RELAY  Press the  OK  key to confirm the choice  The following options are viewed on the display   e OFF     GONG WHILE OPENING   Relay AUX output contact change its state during door opening   e SPACE PERCENTAGE   Relay AUX output contact change its state when the set door width space percentage is reached      THERMIC ALARM SIGNAL    Relay AUX output contact change its state if a thermic alarm is present   e Using keys    and     choose the required option and press the  OK  key to confirm it   If the option  Space percentage  is chosen  the present space percentage is viewed on the display  To modify it  use  key   or V as shown on the display right side  Confirm the required option by pressing the  OK  key  The display shows the confirmed option and restores the m
93. i  funzionamento     Nota  le figure su questo documento sono esemplificative  i componenti del   l impianto possono differire a seconda della configurazione del motore e del   l operatore forniti     2 1 Profilo delle velocit    8     Ciclo di Apertura    01 Accelerazione apertura  02 Alta velocit   apertura  03 Decelerazione apertura    Ciclo di chiusura                                                                            Ci Accelerazione chiusura  c2 Alta velocit   chiusura       Decelerazione Chiusura  8  A APERTURA 4   CHIUSURA   4 LEGENDA  V  m s  Porta in apertura  Porta in chiusura   x  Limite apertura  MAX   lt   gt   1 1 m s Limite chiusura   lt   lt   lt  Ciclo di chiusura    ai   Inversione di moto attiva  a  9    9 Ciclo di apertura   lt   lt   lt      k E  g g 2 109 Attenzione  per porte di gros    gt  se dimensioni         esempio  Ka massa totale in movimento  superiore a 400 Kg     consi   Kc gliabile non modificare il valore  di alta velocit   in chiusura  ji impostato di default  per soddi   sfare i requisiti normativi EN81   limitazione energia cinetica in  Lc I  chiusura                           um     LIFT DOORS          SEMATIC All rights reserved     Changes can be made without notice        808 000 000 505   rel 3    Edition 18 December 2009  3  CARATTERISTICHE GENERALI    3 1 Dati tecnici Sematic Drive System    DC PWM e AC VVVF Brushless        TENSIONE DI ALIMENTAZIONE 90 290 Vac  115 V 20  230V 26   50 60 Hz  POTENZA INSTALLATA 200 VA  POTE
94. i il controller ritorna in modalit   automatica    AUTO        2 2    t   t       e      3  t   ct      t       5  3      a  2     t   3  t   3      x                  ty   lt       E  o      3  et     9              t                           3       lt           t   N  N  t   N  o       Indica Apertura in corso  lampeggiante     Indica Porta Aperta    Indica Chiusura in corso  lampeggiante     Indica Porta chiusa    02  E     Indica Operazioni di Autoapprendimento    Indica Chiusura Forzata    Segnala un allarme e lampeggia in modo alternato con il codice dell allarme rilevato  Vedere capitolo 10     NIZ xL     D Hy O          a a      3  US ZIA               Indica inversione di moto    5 3 Modalita di programmazione    PROG      e Quando il controller sta funzionando in modalit   di programmazione il led rosso    PROG       acceso mentre gli altri due  led rossi sono spenti    Per accedere in modalit   Programmazione premere contemporaneamente il tasto 1 e il tasto 4 per circa 3 secondi fin   ch   non apparir   sul display le          e    00    alternate    e I segnali provenienti dal quadro di manovra e dai dispositivi esterni  barriere  fotocellule      sono ignorati    e Una volta all interno del Modo Programmazione si seleziona il parametro che si vuole modificare con i tasti di incre   mento e decremento  rispettivamente i tasti 2 e 3  e si conferma la scelta del parametro con il tasto 1  ENTER   Quando si    confermato il parametro viene visualizzato sul display i
95. ied to the motor        00  No parking current  In this situation it is possible to open the doors by hand        01  Maximum parking current  The motor does not allow the manual opening of the doors  supplying  current that opposes the opening movement ONLY when necessary        6 16 Skate type  Param  Code 26   This function allows the user to set the skate type   e Standard  STD  skate  Default   the speed profile setting are optimized for the Sematic standard ALU skate type        Expansion  EXP and EXP B  skate  the speed profile setting are optimized for the Sematic 2000 US Expansion skate      N   7N                01  EXP Skate ie  00 Use this setting when you have a single EXP Skate B  STD Skate hole in the upper fixing plate Use this setting when you have two   Aluminium skate   left picture  or you have two holes holes in the upper fixing plate and you           you are connecting the belt to the         connecting the belt to the upper one  lower one  right picture                    Setting a different skate type means telling the controller that different opening dimensions have to be used  20mm  std  90mm exp and 120 mm exp type B  and this allows correct operation in opening and closing cycles     6 17 AUX Input  Param  Code 32   This parameter allow the choose of two possible options     6 17 1 Disabled  default    In this case the door controller implement a complete door opening after a opening command     6 17 2   Partial Reopening   In this case is active
96. ignal and activating the Kc signal     The Main lift controller must steadily monitor the continuous pressure of the car push buttons  open door and floor call  push buttons   performed by the Fireman controlling the installation    During a closing cycle  the release of the floor call push button must release the Kc signal  insert the Ka signal and can   cel the call    During an opening cycle  the release of the door opening push button must release the Ka signal and insert the Kc  signal    At the end of the closing or opening run  detectable through the Lc and La signals respectively  the main lift controller  can detect the release of the floor call or open door push buttons without inserting the Ka and Kc signals respectively   the door controller will wait for a new control signal     Important  Other systems that interface with the Car Door Operator reversing functions  e g  optical bar   riers photocells etc   which are operated by the main lift controller and which may be affected by smoke or heat  should be deactivated by the main lift controller itself     6 10 Double TB  This function allows the Door Controller to store two different door opening widths  TB   for different  floors and on the same side  envisaged in the same installation and operated by the same car door drive         magnetic switch  mounted on the Door Operator by Sematic  is connected to the 15 41 connectors and         is operated by magnets mounted only on the landing doors with different doo
97. il tasto  OK       Sul Display verranno visualizzate le seguenti opzioni      DISATTIVATO      ATTIVATO   e Utilizzando i tasti 4 e V posizionarsi sulla opzione desiderata e confermarla con il tasto  OK    e Il display visualizzer   l opzione confermata e riporter   al men    Opzioni Generali       Sono disponibili le opzioni   e  BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI   e    MENU     premendo il tasto      si ritorna al MENU PRINCIPALE     9 8  Impostazione dell uscita Aux con tastierino  Per il significato di questo parametro vedere il 8 6 7  Utilizzando i tasti 4 e Wscorrere il men   di OPZIONI GENERALI posizionandosi sull opzione USCITA AUX   Confermarla premendo il tasto             Sul Display verranno visualizzate le seguenti opzioni      DISATTIVATO   e GONG IN APERTURA    1l contatto del rele AUX di uscita commuta durante l apertura delle porte   e PERCENTUALE SPAZIO    Il contatto del rel   AUX di uscita commuta quando viene raggiunta la percentuale di spazio porta impostata      SEGNALE PROTEZIONE TERMICA    Il contatto del rel   AUX di uscita commuta in presenza di un allarme di protezione termica     LIFT DOORS    9    808 000 000 505  rel 3     Edition 18 December 2009  Utilizzando i tasti 4 e   posizionarsi sulla opzione desiderata    confermarla con il tasto  OK    In caso si scelga percentuale spazio verr   visualizzato dal display la percentuale di spazio attuale  Per modificarla  utilizzare i tasti 4 e V come indicato sulla destra 
98. introduced for decrease avoid the power consumption of the plant   so to preserve the use of the motor  when it is found in close position     Important note  during the car travel it is necessary that the Main Lift controller gives the closing Kc command   to allow the skate arms closing during the movement     6 15 3 PM activation Delay  Default 300 sec     This sub parameter represents the delay in entering the open skate parking phase after   the activation event represented by the disabling of the closing command KC  So the system waits  for a time equal to the parameter  before opening the skates and going into energy saving condition     6 15 4 PM Opening space  Default 90 mm   The value represents the size of the space reached by the skate when it is completely open during  open skate parking     6 15 5 PM position error  Default 5 mm    This sub parameter represents the space threshold  with relation to the open skate parking point repre   sented by the PM ACTIVATION DELAY parameter  within which the panels can move  When the set value is  exceeded the controller loses the door closed signal LC and activates immediate automatic closure of the  skate  During this last operation the Main Lift Controller should however give the closing or opening com   mand to the door operator     LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    6 15 6 PM position control  Default 00   The sub parameter allows the selection of two different currents that may be appl
99. inuti e confermarla con il tasto  OK    Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI   Sono disponibili le opzioni       BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI       MENU   premendo il tasto F3 si ritorna al MENU PRINCIPALE     9 11  Impostazione dell attivazione della Logica Ingresso Kn con tastierino    Per il significato di questo parametro vedere il 8 6 12   Utilizzando i tasti    e   scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione LOGICA INGRESSO KN  Confermarla premendo il tasto  OK    Sul Display verranno visualizzate le seguenti opzioni    e NORMALMENTE APERTO   e NORMALMENTE CHIUSO   Utilizzando i tasti      e W posizionarsi sulla opzione desiderata e confermarla con il tasto  OK   Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI   Sono disponibili le opzioni        BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI   e    MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE    9 12 Impostazione dell attivazione della Rotazione in Chiusura con tastierino    Per il significato di questo parametro vedere il   6 13   Utilizzando i tasti 4  e V scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione ROTAZIONE CHIUSURA  Confermarla premendo il tasto    OK      Sul Display verranno visualizzate le seguenti opzioni    e SENSO ORARIO   e SENSO ANTIORARIO   Utilizzando i tasti 4 e   posizionarsi sulla opzione desiderata e confe
100. iusura    Su comando d apertura il controller effettua un ciclo d apertura a bassa velocit    il display sul controller visualizza la  scritta  SL  lampeggiante   Durante questa fase verificare attentamente che l operatore effettui la corsa completa    Al termine del ciclo d apertura il ciclo d autoapprendimento    ultimato  la scritta  SL  scompare e riappare  oP          Per uscire dalla modalit   manuale ed entrare in modalit   automatica  premere per alcuni istanti il tasto 4     Nota  il ciclo di autoapprendimento pu   essere effettuato anche in modalit   automatica  i segnali di apertura e chiu   sura porta sono inviati dal quadro di manovra generale  Per iniziare la procedura di autoapprendimento premere per  alcuni istanti il tasto 1  SELF LEARN    L apertura e la chiusura vengono comandate dal quadro di manovra dell ascensore           LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice     23          SEMATIC    All rights reserved   Changes can be made without notice     24    808 000 000 505   rel 3    Edition 18 December 2009  8  MODALITA DI FUNZIONAMENTO CON L UTILIZZO DEL TASTIERINO    8 1 Tastierino  optional           Kit opzionale   cod  B147AABX    Suggerimento    Sebbene il tastierino possa essere collegato direttamente al controller  vedi foto 1  con  il montatore che opera sul tetto di cabina  la situazione ideale    di poter disporre di  una connessione con il controller all interno della cabina  vedi Foto 2     In quest
101. l valore numerico del parametro da modificare   e Con il tasto 2  incremento  e il tasto 3  decremento  modificare il parametro scelto e confermare con il tasto 1 ENTER  le variazioni apportate    Alla fine delle necessarie configurazioni  con il tasto 4 selezionare la modalit   di funzionamento desiderata  manuale   MAN  o automatica    AUTO               LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009  5 4 Verifica del corretto funzionamento del controller SDS    Per verificare il corretto funzionamento del controller seguire le istruzioni sotto        ISTRUZIONE VERIFICA    1  Togliere tutte le connessioni dal controller  anche      alimentazione  2  Verificare il fusibile di alimentazione   Nota  Eventuale sostituzione fusibile     3  Connettere solo il cavo di alimentazione  E       4  Verificare  premendo tasto ON  l accensione del display e  dopo 5s  il lampeggio del display                 5  Premere OFF e connettere motore ed encoder  EE    6  Premere ON e verificare l accensione del display  EE  7  Premendo tasto 4 portarsi in MAN  led MAN acceso   EN    8  Premendo tasto 2 e 3 verificando il movimento parziale del motore  movimento parziale di  apertura e chiusura      Nota  In caso di allarme o mancanza di movimento provare a connettere un altro motore con  encoder  solo connessione dei cavi  non sostituzione meccanica sulla traversa  e ripetere dal  punto 5  al punto 8  Se il nuovo motore funziona correttamente sostituire il motore sulla travers
102. le    3 2 Sematic Drive System  Door Controller  DC PWM and AC VVVF Brushless     OPERATO   CONTR  Sematic            4                                caiano    Y ur       LE a i  6 8 9 10 11       Power ON button   Power OFF button   Display   Manual mode buttons   RJ45 Connection port  Handset    6 poles motor and auxiliary EOD battery power supply connector  cod  E066AARX 05   RJ45 Connection port  Motor optical Encoder    4 poles detector   photocells connector  cod  E066AARX 06    6 poles Main Lift Controller signals connector  cod  E066AARX 03   10 6 poles Main Lift Controller signals connector  cod  E066AARX 04   11 10 poles Main Lift Controller signals connector  cod  E066AARX 07                                        S  etc        88  88  25              2s  oe   lt       5  38  25                 8                     B   e            LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009  3 3 Technical information Sematic Drive System  Brushless Plus  AC VVVF Brushless Plus        MAIN SUPPLY VOLTAGE 230 400 Vac  10   50 60 Hz   CONTROLLER POWER SUPPLY VOLTAGE 36 Vac  10   50 60 Hz   TYPICAL POWER CONSUMPTION 500 VA o 750 VA   PEAK POWER CONSUMPTION 1000 VA  for 500 VA transformers   1400 VA  for 750 VA transformers    MOTOR OVERLOAD PROTECTION  I    15 minutes    021  lt 3 minutes    OPERATIONAL TEMPERATURE RANGE from  10  C to  60  C    HUMIDITY non condensing between 20  and 80   PROTECTION power supply rapid cartridge fuse  30 A   battery power suppl
103. lizzo del tastierino     MODALIT   DI FUNZIONAMENTO CON L UTILIZZO DEL TASTIERINO  8 1  Tastierino  Optional   8 2 Men   e sottomen   tastierino a disposizione  8 3 Attivazione del ciclo di autoapprendimento con tastierino  8 4 Impostazione Forza di inversione di moto con tastierino  8 5 Impostazione Offset d inversione di moto con tastierino  8 6 Profili di velocit   e regolazioni di alta velocit   con tastierino  8 6 1 Opzione    Impostazioni Rapide     8 7 Opzione    Reset Parametri di fabbrica     8 8 Opzione    Area riservata     8 9 Opzione    Impostazioni Avanzate     8 9 1 Opzione    Parametri Apertura     8 9 2 Opzione    Parametri Chiusura   8 9 3 Opzione    Spazio inversione di moto     8 9 4 Opzione    Bus Seriale     8 9 5 Opzione    Modifica Password   8 9 6 Opzione    Salva Profilo     8 9 7 Opzione    Richiama Profilo   8 9 8 Opzione    Download Dati     8 9 9 Opzione    Upload Dati     8 9 10 Opzione    Riaperture dolci       OPZIONI GENERALI   9 1 Impostazione dell attivazione dell inversione di moto con tastierino   9 2 Impostazione dell attivazione dell INGRESSO KN con tastierino   9 3 Impostazione dell attivazione del Test QUADRO DI MANOVRA con tastierino   9 4 Impostazione dell attivazione del Mancanza QUADRO DI MANOVRA con tastierino  9 5 Impostazione dell attivazione dell    Allarme QUADRO DI MANOVRA con tastierino  9 6 Impostazione dell attivazione del Gancio di cabina con tastierino   9 7 Impostazione dell attivazione opzione porte in vetro e porte p
104. ll operatore da Sematic  viene collegato ai morsetti 15   40 e viene comandato da magneti  optional  montati sulle porte di piano designate per l uscita di emer   genza  tramite apposita squadretta di supporto  vedi disegno     Tale segnale permette al controller di comandare l apertura delle porte    Riferirsi all istruzione Sematic 301 036 000  KIT BATTERIE E ATTIVATORE PER SISTEMA DI APERTURA  AUTOMATICA D EMERGENZA  SEMATIC EOD  PER SEMATIC DRIVE SYSTEM  rel  3         6 12 Logica Ingresso Kn  Codice Param  21    Questo parametro serve per impostare la logica dell ingresso Kn  dispositivi di protezione  barriere  fotocellule       Se  il valore di default  0     impostato  il contatto Kn    aperto in condizioni normali e chiuso in presenza di un ostacolo  Se  invece    impostato il valore  1   il funzionamento    invertito  Kn    chiuso in condizioni normali e aperto in presenza di  ostacoli     Attenzione  se la logica selezionata corrisponde a Kn normalmente chiuso  cio   il contatto si apre quando viene  rilevato un ostacolo  e si utilizza uno solo dei due ingressi disponibili  morsetti 15 23 per fotocellule  morsetti  30 31 32 33 per collegamento diretto barriere   occorre fare un ponticello sull altro  Ad esempio se sono instal   late delle barriere con logica N C ai morsetti 31 32 33  occorre fare un ponte tra i morsetti 23 e 15  vicever   sa se vengono collegate delle fotocellule con logica N C ai morsetti 23 e 15 occorre fare un ponte tra i morset   ti 31 e 32    
105. llegamenti elettrici e la tenuta degli stessi sui connettori    Controllare lo stato di tensione e usura della cinghia dentata dell operatore    Controllare e pulire le connessioni dei cavi del motore e dell Encoder del motore     13 RICAMBI  E possibile ordinare tutti i ricambi relativi al Sematic Drive System  contattando il nostro servizio vendita commercia     le e utilizzando il CATALOGO RICAMBI  citando la quantit   desiderata ed il codice relativo al pezzo da ordinare     Il libretto ricambi    di fondamentale importanza per evitare errori di comprensione e per accelerare le fasi di forni   tura dei ricambi stessi  E ricco di fotografie e dettagli e render   semplice e veloce l acquisto di parti di ricambio delle  porte Sematic           LIFT DOORS          SEMATIC    All rights reserved   Changes can be made without notice     97    808 000 000 505   rel 3    Edition 18 December 2009    REVISED INSTRUCTION PROPOSAL FOR THIS HANDBOOK  PROPOSTA DI REVISIONE AL PRESENTE LIBRETTO    Q NOTICE OF NON CONFORMING PRODUCT   SEGNALAZIONE DI PRODOTTO NON CONFORME  Q NOTICE OF IRREGULAR EVENT   SEGNALAZIONE DI EVENTO ANOMALO    Date   Data       Filled in   presentata da       Order reference   Riferimento ordine          Installation site   Luogo di installazione      Town   citt    Q External environment   ambiente esterno all edificio  Q Internal environment   ambiente interno all edificio  Q Ship   nave       PROBLEM FOUND  PROBLEMA RISCONTRATO    ADOPTED SOLUTION  SOLUZIONE 
106. losing limit at low speed  not a self learning cycle     7 2 Self learning cycle with the door controller only  without using the handset    e Power the system   e Turn on the door controller  ON    e For the manual self learning procedure keep key 4 pressed for a while to switch from automatic to manual mode   check that the AUTO red led turns off and the MAN red led turns on       To start up the self learning cycle keep key 1 pressed for a while  SELF LEARN    e The keys 2  opening  and 3  closing  on the door controller command the opening and closing operations     When a closing command is given  the Door Controller carries out a closing cycle at low speed  the Door Controller  display shows the sign  SL   or remains in closed position    When an opening command is given  the Door Controller carries out an opening cycle at low speed  on the Door  Controller display the sign  SL  flashes   During this operation please check carefully that the operator completes its  total expected travel     At the end of the opening cycle  the self learning cycle is complete  the sign  SL  disappears and  oP  appears         Keep key 4 pressed again for a while to activate the automatic mode   Note  the Self Learning cycle can also be started with the door drive in automatic mode  the door close and door open    signals are sent by the main lift controller  To enter the Self Learning phase in Automatic mode just keep the key 1  pressed for a while  then let the main lift controller to s
107. n are ignored  this in order not to interfe   re with the commands sent through the handset    The output LA and LC are both kept OPEN  not valid condition in normal operation    If Monitor menu is selected also Kn is monitored  When the MLC Monitor menu is  selected  though  the system performs as if the handset was not connected at all   allowing the complete monitoring of input output signals by means of the handset               LIFT DOORS    8 2 User Handset menus and submenus       PROFILE SETTINGS    808 000 000 505   rel 3       Edition 18 December 2009             Y       Fast Settings                                                                                                                               Y    Reversing System                                                    Y       Advanced Settings                            Opening parameters    Y             Protective device logic                         cod  21  Closing parameters Y  Closing Rotation  Reversing system cod  22  space Y  Motor    Serial Bus setting          Change Password          Save set data             Closing parking mode  cod  25       Y       Skate type  cod  26       Recall set data          Data Download    Y       AUX input  cod  32          Y          Data Upload    IM signal type                      Smooth Reopening          Y       Set Factory Default          Y       Reserved area             cod  34             LIFT D O O R S    UPDATES  GENERAL OPTIONS MAINTENANCE SELF LEA
108. na  temperatura compresa tra  10 e  60   C e non esposti al sole  e correttamente installati    garantisce il perfetto funzionamento dei prodotti installati in ambienti con temperature comprese tra  10 e  60  C e  umidit   relativa        condensante compresa tra il 20    180      Nota  per temperature e gradi di umidit   al di fuori da questa gamma consultate il ns  Ufficio Tecnico      stesura del presente documento    stata realizzata in conformit   alle seguenti Direttive Comunitarie  UE    Direttiva Macchine 98 37 CE e successive modificazioni  ove applicabile    Direttiva Ascensori 95 16 CEE   Marcatura 93 68 CEE   Movimentazione carichi pesanti 90 269 CEE   Rumore  emissione acustica  86 188 CEE modificata secondo la direttiva 98 24 CEE   Compatibilit   elettromagnetica 89 336 CEE    alle seguenti norme particolari   EN81        AS1735       EN12015 EN12016       EN13015        ASME A17 1  2000       UL508C             gt  per i motori     B105AAAX01   1 Nm Dc  B105AABXO1   1Nm Dc sur demande   B105AAAX02   2Nm Dc  B105AABX02   2Nm Dc sur demande   B105AALX   Dc   GR63x55 SG120   B105AANX   Dc   GR63x25 SG80K   B105AAPX   IP54   DC GR63x25 SG80K   B105AAQX   IP54   DC GR63x55 SG120K   B105AAIX   Brushless   BG62x30 SG80K   B105AAJX   Brushless   BG62x60 SG120   B105AAHX   Brushless   BG62x60 PLG60   B105AAGX   Brushless   B105AATX   IP54 Brushless BG62x30 SG80K   B105AARX   IP54 Brushless BG62x60 SG120K   B105AADX   Dc             solo con motori     B105AAIX   Brushle
109. nder   un nuovo comando     Importante  se sono presenti altri sistemi con funzioni di inversione di moto dell operatore di cabina gestiti dal  quadro di manovra  ad es  barriere ottiche fotocellule etc   il quale funzionamento pu   essere influenzato da  fumo e calore in caso di incendio  essi devono essere disabilitati dal quadro di manovra stesso     6 10 Doppio TB  Questa funzione consente di far memorizzare al controller due aperture differenti  a piani diversi e sullo  stesso lato  presenti su un unico impianto ed utilizzate dallo stesso operatore di cabina    T Un interruttore magnetico  montato sull operatore da Sematic  viene collegato ai morsetti 15 41 e viene     _ comandato da magneti montati sulle porte di piano con TB differente  tramite apposita squadretta di sup    a porto  vedi disegno a lato     Tale segnale permette al controller di discriminare i piani con aperture differenti    e Eseguire un ciclo di autoapprendimento  vedere 8 8 3        Portare la cabina ad un piano con TB differente  al segnale Ka  dato dal quadro di manovra o manual   mente dall installatore  il controller effettua automaticamente un secondo ciclo di auto apprendimento  previa corretta installazione dei magneti sulle porte di piano con TB differente    Nota importante  l opzione Doppio TB    l unico caso in cui il controller pu   eseguire un autoapprendimento in modo   automatico  in realt   esso avviene comunque in seguito alla attivazione di un ciclo di autoapprendimento manua    le
110. ndo il controller si trova in con   dizione di allarme di protezione termica     6 8 Chiusura forzata  Nudging    Qualora nel quadro di manovra fosse previsto il circuito di messa fuori servizio della fotocellula  o dispositivo analogo    dopo diversi tentativi di chiusura senza risultato     possibile comandare la chiusura della porta in bassa velocit    chiu   sura forzata   chiudendo mediante un rel    contatto senza tensione  i morsetti 15 22    Durante la fase di chiusura viene attivata l uscita dei morsetti 15   24V  e 21  Gnd  per l utilizzo diretto di un buzzer  a 24 Vdc max 100 mA  dispositivo non fornito da Sematic   o opportuno rel       6 9 Fire Fighting  Codice Param  19    Il comportamento FIRE FIGHTING    possibile per gli impianti specificamente previsti  dal momento che comporta deter   minate funzioni anche da parte del quadro di manovra dell ascensore    Per i dettagli operativi dell impianto completo si faccia riferimento alle seguenti norme     BS5588 Part 5  1991  EN81 72  2003  ASME A17 1  2000  AS 1735 1  2003    Il Fire Fighting ha un ingresso apposito  Kff   Quando Kff commuta da APERTO a CHIUSO le barriere o i dispositivi simili direttamente o completamente connessi ven   gono ignorati  in quanto questi potrebbero essere influenzati da fumo e calore in caso di incendio  il sistema di inver   sione di moto pu   essere impostato in modo da ignorare gli ostacoli meccanici  parametro 19 0  oppure in modo da  ridurre la sua sensibilit    parametro 19 1  
111. nectors   e Check that the door operator toothed belt is tight enough and in good working condition      Check and clean the cable connections of the motor and of the motor Encoder    13 SPARE PARTS  It is possible to order all the Sematic Drive System  spare parts using the spare parts catalogue  by specifying the    required quantity and the code of the ordered piece     The spare parts manual is extremely important to avoid misunderstandings and to ensure a rapid supply of the cor   rect spare parts  The spare parts catalogue  with photographs and details will make the Sematic doors spare parts  purchase easy and quick         SEMATIC    All rights reserved   Changes can be made without notice     LIFT DOORS          SEMATIC    All rights reserved     a  2  e  2  5                8            2  a  c      8  R  8                       38    808 000 000 505   rel 3        Edition 18 December 2009          LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    Indice  1 PREMESSA pag   2 CHE COS    IL SEMATIC DRIVE SYSTEM  pag   2 1 Profilo delle velocit    3 CARATTERISTICHE GENERALI pag   3 1 Dati tecnici Sematic Drive System   DC PWM e AC VVVF Brushless   3 2 Door Controller Sematic Drive System   DC PWM e AC VVVF Brushless   3 3 Dati tecnici Sematic Drive System  Brushless Plus  AC VVVF Brushless Plus   3 4 Door Controller Sematic Drive System  Brushless Plus  AC VVVF Brushless Plus   4 INSTALLAZIONE E COLLEGAMENTI DA EFFETTUARE pag   4 1  Connessioni Sematic
112. nto    07 Strappo Motore Interruzione dei cavi del motore Auto reset al ripresentarsi delle condizioni  normali di funzionamento  dopo 5 tentativi  in 5 min  il sistema si ferma    08 Sovratensione Sovratensione in alimentazione Il Controller commuta in bassa velocit     segnala l errore ed effettua un auto reset   dopo 5 tentativi in 5 min  il sistema si ferma   09 PWM Trip Sovracorrente impulsiva Auto reset al ripresentarsi delle condizioni  normali di funzionamento  dopo 5 tentativi  in 5 min  il sistema si ferma    10 Allarme interno Allarme dovuto al non corretto funzionamento del con    Auto reset al ripresentarsi delle condizioni   troller  normali di funzionamento    14 Protezione Sovraccarico dell alimentatore Switching interno dovuto   Auto reset al ripresentarsi delle condizioni nor    Alimentatore ad uno sforzo meccanico eccessivo della porta  mali di funzionamento  dopo 5 tentativi in 5  minuti il sistema si ferma   Note     1 Questo allarme pu   intervenire solo se il parametro TEST QUADRO DI MANOVRA    stato impostato come IN MOVIMENTO o IN MOVIMEN   TO STAZIONAMENTO e il parametro ALLARME QUADRO DI MANOVRA    attivato  ON   vedere 8 6 4     2 Questo allarme    comunque indicativo di uno sforzo eccessivo nel funzionamento dell operatore  e consigliabile verificare che il sistema non  presenti attriti  specialmente durante la fase di apertura   3 Questo allarme pu   intervenire solo se il parametro INVERSIONE DI MOTO    stato impostato su  ESTERNA   vedere 8 6 2
113. o il tasto  OK       Sul Display verranno visualizzate le seguenti opzioni      DISATTIVATO      ATTIVATO   e Utilizzando i tasti 4 e V posizionarsi sulla opzione desiderata e confermarla con il tasto  OK    e Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI      Sono disponibili le opzioni       BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI         MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE     9 6 Impostazione dell attivazione del Gancio di cabina con tastierino    Peril significato di questo parametro vedere il 8 6 5  e Utilizzando i tasti 4 e W scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione GANCIO DI CABINA     Confermarla premendo il tasto  OK       Sul Display verranno visualizzate le seguenti opzioni      DISATTIVATO      ATTIVATO   e Utilizzando i tasti 4 e    posizionarsi sulla opzione desiderata e confermarla con il tasto  OK    e Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI      Sono disponibili le opzioni      BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI       MENU   premendo il tasto      si ritorna al MENU PRINCIPALE     9 7 Impostazione dell attivazione opzione porte in vetro e porte pesanti con tastierino  e Per il significato di questo parametro vedere il 8 6 6  e Utilizzando i tasti 4 e Wscorrere il men   di OPZIONI GENERALI posizionandosi sull opzione PORTE IN VETRO E  PORTE PESANTI      Confermarla premendo 
114. o il tasto OK     Nella parte sinistra del display vengono visualizzati tre valori selezionabili con          il valore massimo  MAX   il valo   re attualmente in uso  SET  ed il valore minimo  MIN  espressi in Newton  Una volta selezionati    possibile variare i  valori con     e  gt     Nella parte destra del display viene visualizzata graficamente la percentuale della forza attualmente impostata rispet   to al valore massimo     e Utilizzando i tasti           rispettivamente si diminuisce o si aumenta il valore visualizzato       Premendo il tasto F2   lt  gt         si pu   verificare il funzionamento delle porte con il valore di forza inversione di moto  impostato    e Premendo il tasto       MENU  si ritorna al MENU PRINCIPALE       Premendo il tasto F1  BACK  si ritorna al men   IMPOSTAZIONE PROFILI     8 5 Impostazione Offset d inversione di moto con tastierino   e Collegare il tastierino al connettore RJ45    Utilizzando i tasti 4 e   posizionarsi sulla lingua desiderata e confermarla con il tasto OK    Con i tasti    e W scorrere il MENU PRINCIPALE e posizionarsi su IMPOSTAZIONE PROFILI    Premere OK per confermare la scelta    Sul display verranno visualizzate le seguenti opzioni    e IMPOSTAZIONI RAPIDE   e INVERSIONE DI MOTO   e IMPOSTAZIONI AVANZATE   e RESET PARAMETRI DI FABBRICA      AREA RISERVATA   e Utilizzando i tasti 4 e   scorrere il men   di IMPOSTAZIONE PROFILI posizionandosi sull opzione INVERSIONE DI  MOTO    e Confermarla premendo il tasto OK    e 
115. o modo il montatore si trover   ad operare in situazione di assoluta sicurezza  e potr   controllare il movimento delle porte accoppiate in situazione reale di funzio   namento    Per poter effettuare questo collegamento richiedere alla Sematic l apposito adattatore   vedi foto 3  cod  B147AABX  sar   sufficiente effettuare in qualsiasi punto delle pare   ti della cabina un foro tondo del diametro di 16 mm      Nota  Collegando il tastierino al controller viene visualizzata la data di scadenza della  garanzia  2 anni dalla data di collaudo  e il tempo residuo prima della scadenza in ore  di attivit   dell    impianto    Successivamente viene richiesto di selezionare la lingua     CHOOSE LANGUAGE       Mediante i tasti  amp  e A selezionare la lingua desiderata e confermarla tramite il tasto  OK     Nota importante  quando il tastierino    collegato tutti i segnali dal quadro di mano   vra generale  tranne K2TB se    utilizzato  e Kn sono ignorati  questo per non interfe   rire con i comandi inviati dal tastierino    Le uscite La e Lc sono tenute entrambe aperte  condizione non valida durante il nor   male funzionamento     Se viene selezionata l opzione MONITOR dal men   MANUTENZIONE anche Kn viene  considerato  Se viene selezionata l opzione MONITOR QUADRO DI MANOVRA dal men    MANUTENZIONE  il sistema si comporta come se il tastierino non fosse collegato  per   mettendo la completa visualizzazione sul monitor del tastierino degli ingressi e delle  uscite del controller     
116. o the controller  in case an obstacle is detected the door  open completely  The inversion motion signal IM  reversing motion  is being sent by the controller to the main  lift controller until the doors are fully open     6 4 2 Limited door reversal    This option allow a partial reopening of the doors when an obstacle has been detected by means of optoelec   tronic  traditional or proximity door protection devices  The door re opening only for the time during witch the  obstacle is detected and not necessarily up to open limit  IM  reversing motion  signal is sent to the lift con   troller as long as the obstacle is present     6 4 3 Safety edge    Safety edge and mechanical detection systems are directly connected into Kn contact  the controller manages  the emergency door reopening  The IM reversing motion  is being sent by the controller to the main lift con   troller until the door are fully open     6 5 Car Door Locking Device  USA   Restrictor   Param  Code 05   This option must be set when the optional car door locking device is installed  This function provides for proper opera     tion with the car door locking device   00   gt  Off  without car door lockig device     01   gt  On  with car door lockig device     6 6 Full or framed Glazed and Heavy Paneled Doors  GLASS AND HEAVY DOORS   Param  Code 06   In presence of car and landing door with Glazed Paneled Doors  this feature must be activated  When active  the  OPENING HIGH SPEED as additional featurevalue is res
117. on     The Sematic Drive System   automatically controls the opening and closing  of the lift doors  monitoring the timing  current variations  speeds  high   low  acceleration and deceleration curves   various safety systems  rever   sing system  Limited Door Reversal etc   and faults  high voltage  signal  failure           There are two independent speed curve profiles for the opening and closing  cycles  5  which can be modified by means of the door controller push but   tons or by means of the Sematic handset  an optional 8 digit keypad and  display accessory which can be connected to the card by an RJ45 plug      The handset  6  is a key pad that allows viewing and modification of the  function parameters stored in the controller    It is important to use the Sematic handset for installation or maintenance   as it enables viewing and or variation of the controller parameters  systems   and operation errors     Furthermore  it is possible to use the Sematic handset directly from the insi   de of the car  7     Making it possible to monitor and modify the door operating parameters  from a completely safe position  and also to control the movement of the  coupled car and landing doors during their effective operating cycle     Note  the pictures on this document are examples only  real components  appearances may differ according to supplied configuration of door operator  and motor     2 1 Speed profile  8     Opening Cycle   01 Opening acceleration  02 Opening hight spee
118. on   fidenziali e di propriet   della Sematic e non possono essere copiati o riprodotti in alcuna forma    Ogni informazione contenuta nel sistema  Sematic Drive System   non potr   essere rilasciata ad alcuno  senza l as   senso scritto della Sematic  al di fuori del personale autorizzato dipendente della societ   che si fa carico dell impegno  di riservatezza    La societ   che utilizza il sistema  Sematic Drive System       si impegna a non tentare di utilizzare informazioni confi   denziali della Sematic ed a non ricompilare o reingenerizzare il sistema  Sematic Drive System      e qualsiasi informa   zione ivi contenuta     Please dispose of the  controller correctly     Bitte entsorgen Sie das  Tursteuergerat auf korrekte Weise     Si prega di differenziare    m correttamente il controller   Pri  re de distinguer        correctement le controller                  Rogamos diferenciar la controla  cod  1020211 263 Corectamente                 Sematic Italia Spa  All rights reserved   Sematic regards all the information contained in this instruction manual to be correct at the time of printing  This information does not constitute any obligation to Sematic and can be modified without    prior notification  Sematic cannot be held responsible for any possible damages or claims caused to items or persons due to errors or misunderstandings within the contents of this instruction manual        Sematic Italia Spa  Tutti i diritti sono riservati   Sematic ritiene che le informazi
119. onare la cifra che si desidera modificare  e utilizzare i tasti  M e V per selezionare il numero  Premere Ok per confermare la password inserita     Sul display vengono visualizzate le seguenti opzioni   PARAMETRI APERTURA  PARAMETRI CHIUSURA  SPAZIO INVERSIONE  OPZIONI BUS SERIALE  MODIFICA PASSWORD  SALVA PROFILO  RICHIAMA PROFILO  DOWNLOAD DATI  UPLOAD DATI  RIAPERTURE DOLCI    Utilizzando i tasti    e W scegliere l opzione    RIAPERTURE DOLCI    e confermare con il tasto OK la scelta   Premere OK per confermare la scelta      Sul display verranno visualizzate le seguenti opzioni     e 00  gt  disabilitato  Default      01   gt  abilitato  Utilizzando i tasti 4 e V scorrere il men   e scegliere l opzione desiderata  e Premere      per confermare la scelta   e Il dispay mostra l opzione confermata       Sono disponibili le opzioni            BACK  premendo il tasto F1 si ritorna al men   MENU PRINCIPALE        MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE    a      e       5                   o             o  a                       8   o   c   s  o       SEMATIC    All rights reserved     LIFT DOORS    808 000 000 505   rel 3     Edition 18 December 2009  9 OPZIONI GENERALI    Collegare il tastierino al connettore RJ45    Utilizzando i tasti 4 e   posizionarsi sulla lingua desiderata e confermarla con il tasto OK    Con i tasti 4 e W scorrere il MENU PRINCIPALE e posizionarsi su OPZIONI GENERALI    Premere OK per confermare la scelta    Il men   OPZIONI GENER
120. onarsi sulla opzione desiderata e confermarla con il tasto  OK   Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI   Sono disponibili le opzioni       BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI   e    MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE    9 16 Impostazione dell ingresso AUX con tastierino    Per il significato di questo parametro vedere il 8 6 17   Utilizzando i tasti 4 e V scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione INGRESSO AUX  Confermarla premendo il tasto  OK    Sul Display verranno visualizzate le seguenti opzioni       DISABILITATO        DI RIAPERTURA PARZIALE   Utilizzando i tasti 4 e   posizionarsi sulla opzione desiderata e confermarla con il tasto  OK   Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI   Sono disponibili le opzioni    e  BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI         MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE    um     LIFT DOORS       808 000 000 505   rel 3    Edition 18 December 2009   9 17 Impostazione del tipo di segnalazione inversione di moto con tastierino  e Per il significato di questo parametro vedere il   6 18  e Utilizzando i tasti 4 e W scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione TIPO DI SEGNALAZIONE          Confermarla premendo il tasto  OK      Sul Display verranno visualizzate le seguenti opzioni    e CONTINUA   e MONOSTABILE IMP
121. oni contenute in questo documento alla data della pubblicazione siano corrette  Tali informazioni non costituiscono impegno per la Sematic e possono essere modifica     te senza preavviso  Sematic non si ritiene responsabile per eventuali danni causati a persone o cose a seguito di inesattezze o errate interpretazioni relative al contenuto del presente manuale              LIFT DOORS       SEMATIC    All rights reserved        a  e          E                o              a  S              o     s     o    808 000 000 505   rel 3    Edition 18 December 2009           lt   z  E             sematic com  Sematic Group  Gruppo Sematic   we take care of ci preoccupiamo della vostra  your integrated solutions  soluzione integrata   COMPONENT SYSTEMS COMPONENTI  e Automatic lift doors e Porte automatiche  e Frame and frameless glass doors e Porte in vetro totale e vetro intelaiato  e Enhanced car door operator solutions e Soluzioni avanzate per operatori di cabina  e Complete cabins e Cabine complete  e Car Frames e Arcate  e Custom integrated packages e Pacchetti integrati di componenti  e Special lift doors  cabins and car frames e Porte  cabine e arcate speciali  ELEVATOR SYSTEMS  amp  SUBSYSTEMS SISTEMI  amp  SOTTOSISTEMI PER ASCENSORI     Rope traction elevators e Ascensori a fune  e Machineroomless roped elevators e Ascensori a fune senza sala macchina  e Modular hydraulic elevators e Ascensori modulari idraulici     Hydraulic elevators    Ascensori idraulici  e Panoramic elev
122. ore the menu GENERAL OPTIONS  e  MENU   Press key F3 to restore the MAIN MENU    9 5 Main Lift Controller Alarm    MLC Input Alarm      See 8 6 3 4 for the meaning of this parameter  e Using keys 4 and    run through the GENERAL OPTIONS and choose the option MLC INPUT ALARM  e Press key  OK  to confirm the choice  e The following options are viewed on the display   e OFF  e ON  e Using keys    and V  choose the required option and press the  OK  key to confirm it  e The display shows the confirmed option and restores the menu GENERAL OPTIONS  e The following options are available   e  BACK   Press key F1 to restore the menu GENERAL OPTIONS  e  MENU   Press key F3 to restore the MAIN MENU    9 6 Activation of the Car Door Locking Device setting by means of the Handset  e See 8 6 5 for the meaning of this parameter  e Using keys 4 and    run through the GENERAL OPTIONS and choose the option CAR DOOR LOCKING DEVICE      Press key  OK  to confirm the choice  e The following options are viewed on the display    e OFF   e ON  e Using keys 4 and V  choose the required option and press the  OK  key to confirm it  e The display shows the confirmed option and restores the menu GENERAL OPTIONS  e The following options are available        BACK   Press key F1 to restore the menu GENERAL OPTIONS       MENU   Press key F3 to restore the MAIN MENU    9 7 Activation of the Glazed Paneled and Heavy Doors setting by means of the Handset  e See 8 6 6 for the meaning of this parameter  e Using k
123. orna l indicatore del tempo impiegato per effettuare l apertura con il profilo impo   stato    e Premendo il tasto       NEXT  si prosegue l impostazione dei profili con l impostazione dei PARAMETRI  CHIUSURA  le operazioni da eseguire sono quelle sopra descritte per l impostazione dei PARAMETRI  APERTURA    e Premendo il tasto F1  EXIT  si ritorna al men   IMPOSTAZIONE PROFILI     8 7 Opzione  Reset Parametri di fabbrica   Scegliere questa opzione per ripristinare i parametri di movimento impostati come default dal costruttore     Collegare il tastierino al connettore RJ45    Utilizzando i tasti 4 e   posizionarsi sulla lingua desiderata e confermarla con il tasto OK   Con i tasti 4 e W scorrere il MENU PRINCIPALE e posizionarsi su IMPOSTAZIONE PROFILI   Premere OK per confermare la scelta    Sul display verranno visualizzate le seguenti opzioni    e IMPOSTAZIONI RAPIDE   e INVERSIONE DI MOTO   e IMPOSTAZIONI AVANZATE   e RESET PARAMETRI DI FABBRICA      AREA RISERVATA   Utilizzando i tasti       V scorrere il men   di IMPOSTAZIONE PROFILI posizionandosi sull opzione    RESET PARAMETRI  DI FABBRICA       Confermarla premendo il tasto OK     8 8 Opzione    Area riservata       Collegare il tastierino al connettore RJ45    Utilizzando i tasti 4 e   posizionarsi sulla lingua desiderata    confermarla con il tasto OK   Con i tasti 4 e W scorrere il MENU PRINCIPALE e posizionarsi su IMPOSTAZIONE PROFILI   Premere OK per confermare la scelta    Sul display verranno visualizzate le
124. ose  SELF LEARNING      Using the  OK  key confirm the option   If the operator is not on a closing position use key F2         to allow the door to complete a closing cycle in low speed  Once the closure has been made  push again key F2        to allow a complete opening cycle in low speed    During this operation please check carefully that the operator completes its total expected travel   At the end of the opening cycle the self learning cycle is completed   This will be signalled with the information    Self learning completed         The following will be requested   Guided Profile setting       Press the  OK  key to choose the option  Fast settings   e Press key F1  EXIT  to restore the  main menu       8 4 Reversing System Force setting by means of the handset   e Connect the handset to RJ45 connector   If necessary  using keys    and   choose the required language and confirm with the  OK  key   Using keys    and    run through the MAIN MENU and choose PROFILE SETTING    Press the  OK  key to confirm the option    On the display the following options are viewed    e FAST SETTING   e REVERSING SYSTEM   e ADVANCED SETTINGS   e SET FACTORY DEFAULT   e RESERVED AREA   e Using keys    and   run through the menu  PROFILE SETTING    and choose the option REVERSING SYSTEM     Using the  OK  key  confirm the option   e Using the keys    and    scroll through the REVERSING menu and select the option    REVERSING SYSTEM FORCE  SETTING       Press  OK  to confirm the choice     
125. osed      contact normally open     This signal is generated by dry  voltage free   Form C contacts  relay within the Door  Controller  and is activated only when either a  mechanical obstacle  excessive force  pre   vents the doors from closing  or a signal is  received from an external safety device that is  connected to the door controller    It is used to signal the main lift controller to  interrupt the door close command and give a  door open signal  Contact rating  3A 250Vac  30Vdc       Auxiliary Output Signal AUX    Connector pins  35   34    Connector pins  35   36    These connections provide dry   voltage free  contact      contact normally open      contact normally closed     These contacts can be used to signal that a  particular  pre set  door opening distance has  been achieved  or as a Gong or Buzzer while  the door is opening or as a Thermic alarm  signal    Contact rating  3A 250Vac 30Vdc        Motor    Connector pins  43   44   45    Factory prewired connector       Acoustic alarm   BUZZER    optional           Connector pins  15   21       These connections provide     24Vdc  100ma contact   Contact is open when not active           e For the Door Operator mechanical installation refer to the    Installation and maintenance of Sematic doors    manual        e The door controller is supplied already mounted on the operator  All the connections between the door controller and  the motor are pre wired at Sematic  In order to prevent possible damage to the 
126. ositivo preleva alimentazione e invia il segnale direttamente al con     troller del Sematic Drive System     E possibile il collegamento completo di un detector o fotocellule  con alimentazione    24 Vdc max 100 mA    uscita del    tipo PNP N O o N C  tramite i morsetti                                                              GND GND 33 GND morsetto di massa   OUT PNP N O          Vd     Nec 32 IN segnale PNP N O o N C da detector  NC  24 Vdc IN GND  30 31 32 33    z   31  24 Vdc alimentazione al detector   fotocellule  Esempio di collegamento di    fotocellule barriere con tra   smettitore e ricevitore colle  30 NC morsetto libero  TX   gati fra loro tramite morsetto   RX x          6     di appoggio 30  pu   servire come morsetto di appoggio per i collegamenti fra                      componenti del sistema detector      Le modalit   di gestione della riapertura dipendono dal settaggio dei parametri INVERSIONE DI MOTO  RIAPERTURA  PARZIALE e LOGICA INGRESSO Kn  vedere 8 6 2  6 3 e 6 12         SEMATIC    All rights reserved   Changes can be made without notice           LIFT DOORS       5              55  8 3        s               Sg   gt     lt      DE  28  Se        x    5   ag  Os  o    14    808 000 000 5057 rel 3    Edition 18 December 2009  5 MODALITA DI FUNZIONAMENTO SENZA L UTILIZZO DEL TASTIERINO  Visualizzazioni sul display in Modalit   Automatica e in Modalit   Manuale       SSS              ES T  T   O aR    fet        b                      21 3          
127. ownloaded data to a PC for using  the set data in case of door controller replacements    To save the set data to    PC is necessary to have the Sematic SDS Updater kit  consisting of a E066AAYX cable         Sematic 505 Updater        Datamanager software    rea        Software   Sematic SDS  Updater   PC Datamanager             E066AAYX    8 9 10 Option  Smooth reopening   Selecting this parameter  01  the BHV door controller activate a lower speed profile during the next reopening     Connect the handset to RJ45 connector   If necessary  using keys    and   choose the required language and confirm with the  OK  key  Using keys    and    run through the MAIN MENU and choose PROFILE SETTING    Press the  OK  key to confirm the option   On the display the following options are viewed    FAST SETTING   REVERSING SYSTEM FORCE   ADVANCED SETTINGS   SET FACTORY DEFAULT   RESERVED AREA   Using keys    and    run through the menu  PROFILE SETTING    and choose the option ADVANCED SETTINGS  Using the  OK  key  confirm the option    After confirming the choice by pressing the  OK  key  a 5 code password is required on the display  The factory  default access code is 00001    Use keys     and  gt  to move to different digits and to select the necessary coded digit use keys    and    Press  OK at the end     The following options are viewed on the display   OPENING PARAMETERS    CLOSING PARAMETERS  REVERSING SYSTEM SPACE  SERIAL BUS SETTING  CHANGE PASSWORD   SAVE SET DATA   RECALL SET
128. r opening widths  TB  the    smaller  by means of a special support plate  see drawing   This signal allows the Door Controller to distin   guish floors with different opening width        Complete    self learning cycle  see 8 8 3        e Take the car to a floor with the different TB  upon receiving the Ka signal  given by the main lift con   I troller or manually by the installer  the Door Controller will automatically carry out a second self lear   ning cycle if the magnets on the landing doors with different TB are correctly positioned     Important Note  the double TB option is the only operation in which the door controller can carry out a self   learning cycle automatically  as a matter of fact it takes place anyhow when a manual self learning cycle is acti   vated   It is very important that the installer be present during the second automatic self learning cycle to check    that it is completed correctly  sematic  LIFT DOORS                            SEMATIC    All rights reserved   Changes can be made without notice     19          SEMATIC    All rights reserved         2  e  2  5  3                 S  E  ES  a  E      8      8      s  o    20    808 000 000 SDS  rel 3    Edition 18 December 2009   6 11 E O D   Emergency Opening Device  and timeout  Param  Code 20    In an emergency situation such as a main power supply failure  it may be beneficial that when the car is aligned with  landing doors  inside the lock release zone  they open automatically  remain open
129. re in caso di caduta dei segnali dal quadro di manovra   Sono disponibili le 3 scelte sotto dettagliate     6 3 3 1 Stop immediato  Se    attivata la scelta  STOP IMMEDIATO     impostazione di default   il controller arresta il movimento  delle porte     6 3 3 2 Bassa velocit       stop    Se    attivata la scelta    BASSA VELOCITA     STOP     il controller commuta in bassa velocit   fino al com   pletamento del ciclo interrotto     6 3 3 3 Ciclo Bassa velocit       Con il parametro M ANCANZA QUADRO DI MANOVRA impostato su  CICLO BASSA VELOCITA       se le porte stanno aprendo o sono completamente aperte  il controller attiva l uscita del buzzer  lascia  aperte le porte per un tempo prestabilito e poi comanda una chiusura a bassa velocit        se le porte stanno chiudendo e non hanno ancora raggiunto il limite in chiusura  il controller attiva l u    scita del buzzer  inverte il senso di marcia  fa aprire completamente le porte  le lascia aperte per un   tempo prestabilito e poi comanda una chiusura a bassa velocit      se le porte sono chiuse  il controller le mantiene in questa condizione ed attiva l uscita del buzzer per   un breve periodo    e Il buzzer viene disattivato quando le porte risultano completamente chiuse     6 3 4 Allarme QUADRO DI MANOVRA  Codice Param  03    Questa opzione permette di scegliere se considerare o no un allarme la rilevazione di mancanza di segnale  Ka  o Kc  quando il TEST QUADRO DI MANOVRA attivato    00   gt  Off  funzione disabilitata   
130. re of the main lift controller   The following 3 options are available     6 3 3 1 Instant Stop  If the  INSTANT STOP  option is activated  default setting   the door controller stops the door    movement     6 3 3 2 Low Speed to Stop  If the  LOW SPEED TO STOP  option is activated  the door controller switches to low speed until comple   tion of the interrupted movement     6 3 3 3 Low Speed Cycle   If the parameter NO MLC SIGNAL is set on  LOW SPEED CYCLE     e If the doors are opening or fully opened  the door controller operates the buzzer output  it stays open  for a time then closes at low speed    e if the doors are closing but not fully closed  the door controller operates the buzzer output  reverses  direction  opens fully and stays open for a time then closes at low speed    e if the doors are closed  the doors will stay in the closed position  and the buzzer is operated for a short  time    e The buzzer will be de activated upon door closed     6 3 4 Main Lift Controller Input Alarm  Param  Code 03   This option allows the installer to choose to consider or not to consider a recorded fault the case that the door    controller detects the signal failure  both Ka and Kc  when the MAIN LIFT CONTROLLER TEST is activated   00   gt  Off  function disable   01   gt  On  function able     6 4 Kn Input  Param  Code 04   This parameter allow to choose 3 possible options for the Kn function     6 4 1 Default type    With light photocells or light curtains directly connected t
131. rmarla con il tasto  OK   Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI   Sono disponibili le opzioni        BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI         MENU     premendo il tasto      si ritorna al MENU PRINCIPALE          LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice     33          a      e       5                   o             o  a                   m   8   o   c   s  o       SEMATIC    All rights reserved     34    808 000 000 505   rel 3    Edition 18 December 2009  9 13 Impostazione dell attivazione della Scelta Motore con tastierino    Per il significato di questo parametro vedere il 8 6 14   Utilizzando i tasti 4 e W scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione MOTORE   Confermarla premendo il tasto    OK      Per la versione DC PWM del controller Sematic Drive System    cod  B157AAEX01    sul display del tastierino verr    visualizzata la seguente lista di motori riconosciuti automaticamente     B105AAAX01   B105AAAX02       ESS   B105AALX    Utilizzando i tasti 4 e V    possibili selezionare manualmente i seguenti tipi di motore     DC PWM B105AAAXO01     DC PWM B105AAAX02     DC PWM B105AANX     DC PWM B105AALX     DC PWM B105AAKX     DC PWM S40 V     DC PWM 530 V    Per la versione BRUSHLESS del controller Sematic Drive System  cod  B157AAEX03    sul display del tastierino verr    visualizzato il motore impostato come default     Utili
132. run through the MAIN MENU and choose PROFILE SETTING    Press the  OK  key to confirm the option    On the display the following options are viewed     FAST SETTING  REVERSING SYSTEM  ADVANCED SETTINGS  SET FACTORY DEFAULT  RESERVED AREA    Using keys    and    run through the menu  PROFILE SETTING  and choose the option  SET FACTORY DEFAULT      Using the  OK  key  confirm the option    8 8 Option  Reserved Area    Connect the handset to RJ45 connector   If necessary  using keys    and   choose the required language and confirm with the  OK  key  Using keys    and    run through the MAIN MENU and choose PROFILE SETTING   Press the  OK  key to confirm the option   On the display the following options are viewed     FAST SETTING  REVERSING SYSTEM  ADVANCED SETTINGS  SET FACTORY DEFAULT  RESERVED AREA    Using keys    and    run through the menu  PROFILE SETTING  and choose the option RESERVED AREA  Using the  OK  key  confirm the option          LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice     27       808 000 000 505   rel 3    Edition 18 December 2009   After confirming the choice by pressing the    OK    key  a 5 code password is required on the display  This selection is  reserved for factory use only    Use keys             gt  to insert the codes  to select the required code and modify its value use keys    and V     8 9 Option  Advanced Settings    e Connect the handset to RJ45 connector   If necessary  using keys    and      choo
133. s  through the IM contacts  the presence of an  obstacle to the main lift controller  which in turn must signals the re opening command using Ka  The IM signal is pre   sent up to the complete reopening of the doors     If the main lift controller does not give the re opening signal during the doors movement  the Door Controller com   mands a low speed closure     If the doors are completely open and an obstacle is present  the door controller does not allow the door to close until  a Kb  forced closing  is given from the main lift controller     If the reversing system is EXTERNAL MOVING   PARKING  the Door Controller signals  through the IM contacts  the  presence of an obstacle to the main lift controller  which in turn must signals the re opening command using Ka  The  IM signal is present up to the complete reopening of the doors     If the main lift controller does not give the re opening signal  the Door Controller commands a low speed closure     If the doors are completely open and an obstacle is present  the door controller allows to close the door if a Kb  forced  closing  is given from the main lift controller  If a Kc closing signal is given from the main lift controller  the door con   troller commands    low speed closure and shows a    Reversing system fault       6 3 Main Lift Controller Test  Param  Code 01    When set to  OFF  selection  no MAIN LIFT CONTROLLER TEST   a simple impulse of signal Ka or Kc from the Main Lift  Controller is sufficient to produc
134. s Kn N C ON OBSTRUCTION OPEN  contact opens to signal the presence of an  obstacle  and is used only one protective device input  15 23 terminals for photocells  30 31 32 33 terminals  for direct connection of protective barriers   the other input must be shorted  For example if N C logic protecti   ve barriers are connected to 31 32 33 terminals  23 and 15 terminals must be shorted  if N C logic photocel   Is are connected to 23 and 15 terminals  31 and 32 terminal must be shorted     6 13 Motor Rotation during closing  Param  Code 22   This parameter sets the closing rotation verse  its default value  0  means that the motor turns clockwise during door  closing cycle  the alternative value  1  means that the motor turns anti clockwise during door closing cycle     6 14 Motor type   Sematic Drive System rel  3 door controller may be used with different motors as shown in 8 4 1  DC  Brushless or Brushless  Plus   The door controller automatically recognizes as default the connected motor type  from the standard Sematic motor list   Where necessary it is possible to manually choose the motor type from the complete Sematic list of motors   see 8 9 13  for the motor list      6 15 Closing parking mode  Param  Code 25   This function allows the user to choose the closing parking mode     6 15 1 Closed skate parking  default   The motor is powered during the closing door parking condition and the operator skate arms are closed     6 15 2 Opened skate parking  This option has been 
135. se the required language and confirm with the  OK  key   Using keys    and    run through the MAIN MENU and choose PROFILE SETTING    Press the  OK  key to confirm the option   On the display the following options are viewed    e FAST SETTING   e REVERSING SYSTEM   e ADVANCED SETTINGS   e SET FACTORY DEFAULT   e RESERVED AREA   e Using keys    and      run through the menu    PROFILE SETTING    and choose the option ADVANCED SETTINGS  e Using the  OK  key  confirm the option       After confirming the choice by pressing the  OK  key  a 5 code password is required on the display  The factory default  access code is 00001    Use keys     and 3   to move to different digits and to select the necessary coded digit use keys    and    Press OK at  the end     The following options are viewed on the display   OPENING PARAMETERS    CLOSING PARAMETERS  REVERSING SYSTEM SPACE  SERIAL BUS SETTING  CHANGE PASSWORD   SAVE SET DATA   RECALL SET DATA   DATA DOWNLOAD   DATA UPLOAD   SMOOTH REOPENING    Using keys 4  and W run through the menu and choose the required option  e Using the  OK  key  confirm the option  e The following options are available    e  BACK   press key F1 to restore the Main Menu   e    MENU     press key F3 to restore the Main Menu    The following diagram shows the correspondance between speed profiles and available parameters     A  9   4                               03   4  4                    01  Low start speed   1  Low start speed  02  Acceleration start C2  A
136. segnale viene memorizzato dal controller  che completa la corsa richiesta anche  se il segnale viene a mancare La durata dell impulso deve essere di almeno 400ms    Quando il TEST QUADRO DI MANOVRA    impostato  IN MOVIMENTO    o impostato  IN MOVIMENTO    STAZIONAMENTO     la funzione    come descritta nei prossimi due paragrafi     6 3 1 Test Quadro di Manovra  In Movimento   Default    Quando questo parametro ha l impostazione di default  IN MOVIMENTO     il controller verifica la presenza del  segnale Ka o Kc proveniente dal quadro di manovra solo durante il movimento delle porte  durante il ciclo d a   pertura del segnale Ka  durante il ciclo di chiusura del segnale Kc     Al termine del movimento  rilevabile tramite i segnali La e Lc  rispettivamente di fine apertura e di fine chiusu   ra     possibile rimuovere il segnale che ha determinato il movimento  senza che il controller rilevi un errore   Per questa impostazione    previsto che i quadri di manovra posseggano 2 rel    1 per il comando di apertura  1  per il comando di chiusura    Il controller verifica la continua presenza dei segnali Ka e Kc provenienti dal quadro di manovra    Il controller rileva cadute di segnali maggiori di 200ms e le interpreta come Allarme Mancanza QUADRO DI  MANOVRA se il parametro corrispondente TEST QUADRO DI MANOVRA    impostato  IN MOVIMENTO      Nel caso di mancanza del segnale  il controller si comporta secondo l impostazione del parametro MANCANZA  QUADRO DI MANOVRA  vedere 8 6 4 
137. set  e See 8 6 3 for the meaning of this parameter  e Using keys    and    run through the GENERAL OPTIONS and choose the option MAIN LIFT CONTROLLER TEST  e Press the  OK  key to confirm the choice  e The following options are viewed on the display    e WHEN MOVING      WHEN MOVING PARKING   e OFF  e Using keys 4 and   choose the required option and press the  OK  key to confirm it  e The display shows the confirmed option and restores the menu GENERAL OPTIONS  e The following options are available    e  BACK   Press key F1 to restore the menu GENERAL OPTIONS   e  MENU   Press key      to restore the MAIN MENU          LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice                    2  5  3             8  S  E                 8      8      s  o       SEMATIC    All rights reserved     32    808 000 000 505   rel 3    Edition 18 December 2009  9 4 Activation of the Main Lift Failure by means of the Handset  e See 8 6 3 3 for the meaning of this parameter  e Using keys    and    run through the GENERAL OPTIONS and choose the option NO MLC SIGNAL  e Press the    OK    key to confirm the choice  e The following options are viewed on the display   e IMMEDIATELY STOP  e LOW SPEED   STOP  e LOW SPEED CYCLE  e Using keys 4          choose the required option and press the  OK  key to confirm it  e The display shows the confirmed option and restores the menu GENERAL OPTIONS  e The following options are available       BACK   Press key F1 to rest
138. ss   BG62x30 SG80K  B105AAJX   Brushless   BG62x60 SG120  B105AALX   Dc   GR63x55 SG120  B105AANX   Dc   GR63x25 SG80K          LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice           SEMATIC    All rights reserved        a  2  e  2  5                8            2  a          8      8                      808 000 000 505   rel 3    Edition 18 December 2009  Considerando  in fase di progettazione  i requisiti di sicurezza  Risk Assessment  relativi a     A     PERICOLI DI NATURA MECCANICA   e Schiacciamento in fase di funzionamento      Schiacciamento a causa di trascinamento  vetro       Taglio per la presenza di spigoli vivi  taglienti o pezzi di forma aguzza anche se immobili    PERICOLI DI NATURA ELETTRICA  e Contatto di persone con elementi in tensione  contatto diretto      Contatto di persone con elementi che si trovano in tensione in caso di guasto  contatto indiretto       PERICOLI DI NATURA TERMICA      PERICOLI GENERATI DAL RUMORE    PERICOLI GENERATI DA VIBRAZIONI      PERICOLI GENERATI DA MATERIALI E SOSTANZE          LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009    2 CHE COS    IL SEMATIC DRIVE SYSTEM     5 V  m s                                                  Il sistema    composto da    e un operatore  1    e una scheda elettronica a microprocessore  door controller   2    e da un motore  DC con spazzole o DC Brushless senza spazzole   3  retroa   zionato  4    e Solo per la versione Brushless Plus  
139. ssibilit   di aprire manualmente le  ante       01  Corrente di stazionamento massima  Il motore non consente l apertura manuale delle ante ero   gando una corrente in opposizione al movimento di apertura SOLO quando necessario        6 16 Scelta del tipo di scivolo  Codice Param  26    Questo parametro serve per impostare il tipo di scivolo    e Scivolo Standard  STD  Default   le impostazioni del profilo di velocit   sono ottimizzate per l utilizzo sull operatore  dello scivolo in alluminio Standard Sematic       Scivolo ad Espansione  EXP e EXP B  le impostazioni del profilo di velocit   sono ottimizzate per l utilizzo sull opera   tore dello scivolo ad espansione Sematic 2000 US     EN a EN                01  EXP Skate Fg  00 Scegliere questo settaggio se    presen  EXP Skate B  STD Skate te un solo foro nella piastra di fissaggio   Scegliere questo settaggio quando ci   Aluminium skate   figura a sinistra  oppure quando ci   sono due fori nella piastra di fissaggio e    sono due fori e la cinghia    collegata a  la cinghia    collegata a quello superiore   quello inferiore  figura a destra                     6 17 Ingresso AUX  Codice Param  32   Il parametro    Ingresso Aux    consente la scelta di due possibili opzioni     6 17 1  Disattivato  default    Se    attiva questa funzione il controller effettua  dopo il comando di apertura una apertura completa delle porte     6 17 2    apertura parziale    In questo caso    attiva la    apertura parziale   della porta  impo
140. stata in percentuale  ad un certo piano o selezio   ne a chiave  L ingresso Aux    viene abilitato e il controller apre le porte  dopo il comando di riapertura  fino alla  percentuale di spazio di auto appredimento precedentemente impostata    6 18 Tipo segnalazione inversione di moto  Codice Param  34   Questo parametro permette di scegliere 3 differenti segnali per gestire l inversione di moto esterna al quadro di mano   vra     6 18 1 Impulsiva   IM  inversione di moto     attiva fino a che non arriva KA  rel   di apertura porte  dal monitor quadro di manovra  MLC      6 18 2 Continua  default    IM  inversione di moto     attiva fino alla riapertura completa delle porte LA  limite apertura porte      6 18 3 Monostabile impulsiva   IM  inversione di moto     attiva solo per un tempo prefissato di 0 5  sec   Dopo questo intervallo di tempo l u     scita viene disabilitata        SEMATIC    All rights reserved   Changes can be made without notice      d       LIFT DOORS    808 000 000 5052 rel 3     6 19 Allarmi   Il controller Sematic Drive System   ha la capacit   di diagnosticare e registrare un certo numero di situazioni anomale   tale diagnostica    di aiuto al manutentore per la individuazione degli eventuali problemi di funzionamento    AI verificarsi di un qualsiasi errore monitorabile comparir   la segnalazione sul display del controller seguita dal codice    Edition 18 December 2009       dell errore occorso  La tabella seguente riporta il tipo di segnalazione e il
141. t  the end     8 9 6 Option  Save set data   This option allows the user to save the speed profile  set through the  Fast Settings  or  Advanced Settings  menues             SEMATIC    All rights reserved   Changes can be made without notice     8 9 7 Option    Recall set data     This option allows the user to recall the previously saved speed profile   If no profile was stored in memory the system recalls the default profile           LIFT DOORS    808 000 000 505   rel 3    Edition 18 December 2009  8 8 8 Option    Data Download     This option allows the user to transfer the stored    General Options    and    Profile settings    data from SDS rel  3  controller to SDS rel  3 handset   At the end of the download the controller operates a reset   Wait until    Download OK    message is shown on the handset display     8 9 9 Option    Data Upload      This option allows the user to transfer the previously downloaded data from SDS rel  3 handset to a new SDS  rel  3 controller    Selecting this option it is possible to transfer only the speed profile     Profile settings    menu  or the    General  options    menu settings    Using keys    and   choose the required data transfer and confirm with the            key  At the end of the down   load the controller operates a reset        Note  Download and Upload options are very useful should it be necessary to trasfer the Settings from a door  controller to other similar lift installations controllers  Is possible to save the d
142. tasto      si ritorna al MENU PRINCIPALE    8 9 3 Opzione  Spazio di inversione    Questa opzione permette all utente di definire lo spazio entro il quale la porta esegue un inversione di moto  cau   sata dalla presenza di un ostacolo rilevato dai sistemi di riapertura   Aumentando lo spazio aumenta il ritardo  con cui viene eseguita la riapertura e viceversa    Per modificare il valore di spazio di inversione corrente utilizzare i tasti 4 e    e confermare con il tasto OK        Sono disponibili le opzioni     e  BACK  premendo il tasto F1 si ritorna al men   MENU PRINCIPALE        MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE    8 9 4 Opzione  Bus Seriale    Questa opzione permette all utente di selezionare la modalit   di interfaccia con Bus Seriale   Sul display vengono visualizzate le seguenti opzioni    e BUS OFF  Default    TEST   SEM BUS   RESERVED   SWS MASTER   SWS SLAVE    Utilizzando i tasti 4 e W scegliere l opzione desiderata e confermare con il tasto OK la scelta     Nota  In caso di impianti inclinati che prevedono il Sematic Wireless System  attivare le opzioni    SWS MASTER   e    SWS SLAVE    CONSULTANDO il manuale utente 809 000 000 Sematic SWS     8 9 5 Opzione  Modifica Password    Questa opzione permette all utente di cambiare la password a suo piacimento  inserire la nuova password come  indicato a seguito    Per inserire le cifre utilizzare i tasti       e    per selezionare la cifra che si desidera modificare  e utilizzare i tasti  A e 
143. te al controller di discri   15 41 necessari contatti senza tensione    minare i piani con aperture differenti  In pre    contatto normalmente aperto  senza del segnale le operazioni di apertura e di  chiusura vengono eseguite facendo riferimen   to ad una misura alternativa di TB  larghezza  della porta rilevata da un autoapprendimento  supplementare    Segnali Encoder Connettore   Connettore precablato in fabbrica  RJ45  A   Contatto KEOD morsetti Per questo collegamento    neces    Questo ingresso serve ad indicare al Door con   15   40 sario un contatto senza tensione    tro ler l utilizzo del Sematic E O D Emergency   contatto normalmente aperto  Opening Device  Tastierino  Opzionale  Connettore  RJ45  B   Contatto Ausiliario Kaux morsetti Per questo collegamento    neces   15 42 sario un contatto senza tensione    contatto normalmente aperto                    LIFT DOORS       SEMATIC    All rights reserved   Changes can be made without notice     11                   SEMATIC    All rights reserved     Changes can be made    12    808 000 000 505   rel 3    Edition 18 December 2009    Nota  Il controller Sematic Drive System   pu   funzionare anche con segnali in entrata da quadro di manvora con ten   sioni comprese      un range tra 6 e 24 Vcc   Per poter utilizzare questa caratteristica    e Togliere il ponticello tra i morsetti 37 38  e Collegare il morsetto 38 allo OV dell alimentazione esterna dei segnali in entrata       SEGNALI IN USCITA DAL CONTROLLER           
144. tricted to conform to EN81 1 2 Standard  7 2 3 6 d  and    8 6 7 5 d   Note  activate this option also with heavy doors paneled applications     00   gt  Off  function disable   01   gt  On  function able     6 7 AUX Output Relay  Param  Code 07   This option can be used to signal the achievement of a particular opening distance  pre set  or as Gong while opening   device not supplied by Sematic   Note  default setting  00   gt  off          LIFT D O O R S    808 000 000 505  rel 3     Edition 18 December 2009  6 7 1 Space Percentage  If set  this option allows the AUX Output Relay contacts to send a signal during door opening that relates to a  pre set distance percentage  in comparison to the total door opening  and a signal during the door closing up  to the same opening percentage     6 7 2 Gong While Opening  If set  this option allows the AUX Output Relay contacts to send a signal during the door opening  to a device  not supplied by Sematic      6 7 3 Thermic alarm signal  If set  this option allows the AUX Output Relay contacts to send a signal during a thermic protection alarm pre   sence     6 8 Forced Closing  Nudging    If the main lift controller operates with a disabling photocell circuit  or similar device   after several failed attempts at  closure  it is possible to command the closure of the doors in low speed  forced closing   by closing the 15 22 connec   tor pins by means of a relay  voltage free contact     During the closing cycle the connector 21  Gnd 
145. ulse       01  gt       continuous       02   gt  Monostable pulse  5                            sematic  LIFT DOORS    808 000 000 505   rel 3     Edition 18 December 2009  6 FUNCTIONS AVAILABLE    6 1 Reversing  Parameter for managing the reversing function during the door closing cycle  This is divided into     6 1 1 Reversing system force setting  Param  Code 09   The reverse motion torque parameter sets the sensitivity degree to detect an obstacle during the door closure   thus giving the reopening command  The parameter s value can be manually set     Please note that a minor sensitivity corresponds to higher values and vice versa  After a number of operations   such parameter may change due to an automatic adjustment system     6 1 2 Reversing system offset   The set value represents the size of the space  expressed as a percentage  for disabling the  Reversing  func   tion  By decreasing the percentage  values    100   the controller is able to improve the reactivity of the system  in reversing situations even with obstacles with small dimensions     6 2 Reversing System choice  INTERNAL or EXTERNAL  Param  Code 00    If the reversing system is INTERNAL  the reopening of the doors due to obstacle detection is solely controlled by the  Door Controller and door reopening is signalled to the main lift controller through the IM contacts  1  4 contacts nor   mally closed  2  4 contacts normally open     If the reversing system is EXTERNAL MOVING  the Door Controller signal
146. utgoing signals from the door controller       cod  B105AABXO1  IP54   1Nm Dc    cod  B105AAAXO1  IP23   1 Nm Dc    cod  B105AAAX02  IP23   2Nm Dc    cod    105          2  IP54   2Nm Dc    cod  B105AALX     IP54  option    Dc  GR63x55 SG120  cod  B105AAQX    cod  B105AANX     IP54  option    Dc  GR63x25 SG80K  cod  B105AAPX             cod  B105AAJX     IP54  option   Brushless  BG62x60 SG120  cod  B105AARX    cod  B105AAIX     IP54  Option   Brushless  BG62x30 SG80K  cod  B105AATX    cod  B105AAHX     IP54  option     Brushless    BG62x60 PLG60          EOD Kit  option     Tk   Tk       Safety chains    cod  B105AAGX  IP65  Brushless    Note  this motor is  available only for SDS  Brushless Plus  con     troller          cod  B105AADX      with these  IP54   EEx motors the com   Dc plete Sematic   Drive System     operator acquires  the IP43 protec   tion        Photocells  or Detectors       INCOMING SIGNALS FROM THE DOOR CONTROLLER       Signal    Connector Pins    Contact Type  amp  Normal State    Notes       Opening control Ka     coming from the Main Lift Controller     Connector pins  5   15    These connections require dry   voltage free  contacts   contact open when inactive        Closing control Kc     coming from the Main Lift Controller     Connector pins  3 15    These connections require dry   voltage free  contacts   contact  open when inactive     When the Door Controller is installed on a  Front  amp  Rear entrance car  it is important that  the opening an
147. w speed    signals the error  and performs an auto   reset  after 5 occurrences within 5 minutes  the system stops   09 PWM Trip Impulse over current Auto reset when proper condition is resto    red  after 5 occurrences within 5 minutes  the system stops    10 Internal Fault Generic alarm due to an internal malfunction of the Door   Auto reset when proper condition is resto   Controller red    11 Power supply protec   Internal switching power supply over current  due to Auto reset when proper condition is resto    tion mechanical strain red  after 5 occurrences within 5 minutes  the system stops   Notes        1 This alarm can only occur if the MAIN LIFT CONTROLLER TEST has been set either to  WHEN MOVING  or  MOVING  PARKING  and the  MAIN  LIFT CONTROLLER INPUT ALARM  parameter has been set to  ON   see 8 6 4     2 This alarm indicates an excessive strain in the operator s functioning  it is advisable to check that the system has no friction whatsoever   especially during the opening phase    3 This alarm can only occur if the REVERSING SYSTEM parameter has been set to    EXTERNAL     see 8 6 2     4 If both connections  motor and Encoder signals  are inverted  the door opens when a closing signal is received and closes with an opening  signal  The Door Operator is pre wired and tested by the manufacturer  so special attention must be taken when replacing motor and or  cables           SEMATIC    All rights reserved     Changes can be made    22    LIFT DOORS    808 000 000
148. wiring cables by coming into contact  with the drive belt  they are fixed to the header as shown in the following image  only for B105AAIX  B105AAJX   B105AAKX  B105AANX and B105AALX                                               205  i   A  AN                                                                                                                                        Eeeeessss                                                           O                                                                                                                                                 Note  In case of motor replacement be sure to bind the excess cable lenght as above pictured  to avoid any con   tact of the motor cable with the driving belt     e Warning  to avoid possible induced currents within field wiring  it is recommended to shield the Ka and Kc signals   connector pins 3  5 and 15  with grounded  shielded cables    e Changes made to the factory wiring length or position can damage the EMC system characteristics and is not recom   mended     4 4 Detector Photocell Barriers  Signal Only Connection to the Door Controller  Direct Connection    This connection requires a dry  voltage free  external relay contact connected to the Door Controller Connector pins 15   amp  23    If desired  it is possible to connect the single output signal from a photocell  or similar device  formed by a voltage free  contact  so that the door controller will directly receive the command to r
149. y rapid cartridge fuse  30 A   PERFORMANCE SPEED separately adjustable for opening and closing  REVERSAL SENSITIVITY Variable  only operational on door closing cycle    3 4 Sematic Drive System  Brushless Plus Door Controller  AC VVVF Brushless Plus     cod  B157AAEX05    Brushless PLUS               O                 lt   U    OPERATOR  CONTROLI    392322 3 515 p  118181746 2 4   a    424140383721       Power ON button   Power OFF button   Display   Manual mode buttons   RJ45 Connection port  Handset    Motor and auxiliary EOD battery power supply  controller integrated connector   RJ45 Connection port  Motor optical Encoder    4 poles detector   photocells connector  cod  E066AARX 06    6 poles Main Lift Controller signals connector  cod  E066AARX 03   10 6 poles Main Lift Controller signals connector  cod  E066AARX 04   11 10 poles Main Lift Controller signals connector  cod  E066AARX 07   12 36 Vac   Gnd power supply  controller integrated connector     OANA U j Q N F      SEMATIC    All rights reserved  Changes can be made without notice               LIFT DOORS    808 000 000 508 rel 3    Edition 18 December 2009  4 SIGNALS TO FROM THE DOOR CONTROLLER    4 1 Sematic Drive System    DC PWM and AC VVVF Brushless  connections    505   DC PWM  sematic    ELEVATOR PRODUCTS      FOR FURTHER INFORMATION REFER TO THE USER S GUIDE    FUR WEITERE INFORMATIONEN BENUTZEN SIE BITTE DAS HANDBUCH    PER MAGGIORI INFORMAZIONI RIFERIRSI AL MANUALE UTENTE                      PROTECTION 
150. zione desiderata  e Confermarla premendo il tasto  OK     Se l opzione scelta    MONITOR il display visualizzer   il profilo di velocit   attuale segnalandone le variazioni durante i   cicli di apertura e di chiusura della porta    Sono disponibili le opzioni    e    LOOP     premendo il tasto F1 la porta esegue cicli di apertura e chiusura consecutivi  fino ad un ulteriore pressione  del tasto F1  Prima del movimento    possibile impostare il tempo di pausa tra apertura e chiusura confermandolo  con OK    e     lt  gt     o     gt  lt   premendo il tasto F2 rispettivamente si aprono o chiudono le porte         MENU     premendo il tasto      si ritorna al MENU PRINCIPALE    Se l opzione scelta    STATISTICHE il display visualizzer   il tempo totale di lavoro del controller espresso in  giorni ore minuti  il Numero di cicli compiuti in tale tempo e la data di collaudo    Sono disponibili le opzioni        BACK   premendo il tasto F1 si ritorna al men   MANUTENZIONE   e  MENU   premendo il tasto      si ritorna al MENU PRINCIPALE    Se l opzione scelta    ULTIMI ALLARMI il display visualizzer   gli ultimi allarmi occorsi indicandone il codice  la descri   zione e il tempo di registrazione  giorno ora minuto dalla messa in funzione del controller   Con i tasti 4 e   scorrere  l elenco degli allarmi memorizzate    Sono disponibili le opzioni    e  BACK   premendo il tasto F1 si ritorna al men   MANUTENZIONE       CANC   premendo il tasto F2 si cancellano gli allarmi memorizzati 
151. zzando i tasti 4 e W    possibili selezionare manualmente i seguenti tipi di motore      Brushless B105AAJX     Brushless B105AAIX     Brushless B105AAHX   La versione BRUSHLESS PLUS del controller Sematic Drive System  cod  B157AAEX05       abbinata solo al motore  B105AAGX    9 14 Impostazione dell attivazione del Tipo di Stazionamento in chiusura con tastierino    Per il significato di questo parametro vedere il 8 6 15  Utilizzando i tasti 4 e   scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione TIPO STAZ  CHIUSURA  Confermarla premendo il tasto  OK   Sul Display verranno visualizzate le seguenti opzioni      SCIVOLO CHIUSO     SCIVOLO APERTO  e PM ACTIVATION DELAY  e PM OPENING SPACE  e PM POSITION ERROR  e PM POSITION CONTROL    Utilizzando i tasti 4 e   posizionarsi sulla opzione desiderata e confermarla con il tasto  OK   Il display visualizzer   l opzione confermata e riporter   al men   OPZIONI GENERALI   Sono disponibili le opzioni       BACK   premendo il tasto F1 si ritorna al men   OPZIONI GENERALI   e    MENU     premendo il tasto F3 si ritorna al MENU PRINCIPALE    9 15 Impostazione del tipo di scivolo con tastierino    Per il significato di questo parametro vedere il 8 6 16   Utilizzando i tasti 4 e   scorrere il men   di OPZIONI GENERALI posizionandosi sull opzione TIPO SCIVOLO  Confermarla premendo il tasto  OK    Sul Display verranno visualizzate le seguenti opzioni    e TIPO STD   e TIPO EXP      TIPO EXP B   Utilizzando i tasti 4 e   posizi
    
Download Pdf Manuals
 
 
    