1. 3 Customer means any entity who buys or leases the subject pumps from a dealer The customer may mean an individual partnership corporation limited liability company association or other legal entity which may engage in any type of business THIS WARRANTY EXTENDS TO THE DEALER ONLY Xylem sn 1 2881 East Bayard Street Ext Suite A Lets Solve Water Seneca Falls NY 13148 Phone 800 453 6777 Fax 888 322 5877 www xyleminc com brands gouldswatertechnology Goulds is a registered trademark of Goulds Pumps Inc and is used under license 2012 Xylem Inc 1M078 Revision Number 4 March 2012 MANUAL DE INSTRUCCI N IMO78 Mantenga este manual para consultas Serie Marlow 20EVP INSTRUCCIONES DE INSTALACI N OPERACI N Y MANTENIMIENTO g GOULDS a xylem brand ndice TEMA ROTACION triada rias RE Almacenamiento de invierin0 cccccecccsscscescecesceessessnccuecsceseccesceessnsssesueeseesesceseseesnees Ei DRI CACO 535 iii ias Mantenimiento sa a ira dass dasa died eee dana oia ricas PN ea A en Preca CION ii di Instrucciones para electricistas con licencia serrie iaa aa ia a nn Gu a de soluci n de fallas ccccccesssscssccccecececcsssscssececescesscescssesensesesseessessecseneessnsenaeeeess Refacciones nai tdas Garant a limitada 22 A lt canadien ist danse eee Informaci n del propietario Favor de copiar a continuaci n los datos de la placa de datos de su bomba La informaci
2. Pr cautions recommand es dense ere in ei tell Directives d utilisation sens TN Utihisationis stef enbennnsss ee ein iii AIMOEGA RE vi daceseds cessivaaiesbsvesnatcacsundsssucics E A E E doses SENS de FOCAL OM iii Entreposage hivernal iii le AR te NM e NT in ereieiet diet ubrificattonsssstissee rime aiete iia A NS Directives pout les lecttici ns iia asc Diagnostic des anomalies ein liste de pieces de reCh ange eevee ee oia Garantie limMit C ooonnnncnccnonnnnnnnnnononcnnnnnonanoncnnnonananrccnononnnnrrnononanonocnnncn nano corno nenonanccnnenaniniccnanes Informations pour le propri taire Inscrire ci dessous les informations pertinentes indiqu es sur la plaque signal tique de la pompe La garantie se trouve en page 24 N de mod le de la pompe N de s rie de la pompe D taillant N de t l du d taillant Date d achat Date d installation 18 F LICITATIONS Vous tes maintenant propri taire d une pompe Goulds Water Technology soigneusement inspect e et soumise aux derniers essais avant de recevoir l autorisation d exp dition Pour en maximiser les performances suivre les directives du pr sent manuel PR CAUTIONS RECOMMAND ES 1 S assurer que la pression du syst me ne d passe pas la pression de service maximale de la pompe 2 Si la temp rature du liquide devait exc der la temp rature ambiante de plus de 50 F poser un joint de di latation sur
3. La liste de pi ces et le dessin figurant dans la pr sente page s appliquent divers mod les de pompes Goulds Water Technology y compris la 20EVP Au besoin se servir de la liste et du dessin pour trouver le num ro et le nom d une piece remplacer puis les indiquer au detaillant Goulds Water Technology ainsi que les num ros de modele et de s rie de la pompe mentionn s sur la plaque signal tique de cette derniere 22 NOTES 23 GARANTIE LIMIT E DE GOULDS WATER TECHNOLOGY La pr sente garantie s applique chaque pompe de syst me d alimentation en eau fabriqu e par Goulds Water Technology Toute pi ce se r v lant d fectueuse sera remplac e sans frais pour le d taillant durant la p riode de garantie suivante expirant la premi re douze 12 mois compter de la date d installation ou dix huit 18 mois partir de la date de fabrication Le d taillant qui aux termes de la pr sente garantie d sire effectuer une demande de r glement doit s adresser au distributeur Goulds Water Technology agr chez lequel la pompe a t achet e et fournir tous les d tails l appui de sa demande Le distributeur est autoris r gler toute demande par le biais du service la client le de Goulds Water Technology La garantie ne couvre pas a les frais de main d uvre ni de transport ni les frais connexes encourus par le d taillant b les frais de r installation du mat riel r par c les frais
4. NOT plug this vent If leakage becomes excessive replace the seal assembly MAINTENANCE e If your pump is not used for a few days drain the liquid completely This will prevent aggravating costly rust formations All electrical work MUST be done by a licensed electrician Before working on motors be certain that the electrical power is off at the main junction box Disconnect the fuse or circuit breaker and have the main switch tagged Do Not Ener gize This Switch Personnel Working on Equipment CAUTION Some motors are equipped with built in thermal over loads to shut off the motor in the event the temperature becomes excessive as a result of mechanical or electrical problems such as low voltage poor ventilation overloaded lines etc These motors will restart automatically as the motor cools down For safety sake do not work on any motor without first shutting off the electricity at the source as outlined above in the Warning Also all three phase motors are not thermal protected and motor starters are recommended INSTRUCTIONS FOR LICENSED ELECTRICIANS TURN POWER OFF 1 Determine the voltage of the power supply line to motor Voltage phase ampere draw and cycles are given on the motor nameplate The wire used to supply power to the motor must be large enough to carry the amperes for the required length without excessive voltage drop The follow ing table is meant to be a guide only to the mi
5. lado del tanque Utilice un compuesto para tuber a cuando co loca de nuevo el tap n en el codo lateral Estas bombas Goulds se ceban de manera autom tica siempre que el tanque de la bomba est lleno de l quido Si perdiera el l quido del tanque de manera accidental o por drenarlo a prop sito ser necesario rellenarlo con l quido antes de arrancar la bomba Las elevaciones de succi n altas o l neas de succi n largas requieren tiempo adicional y reducen el desempe o de la bomba Si tiene dificultades consulte la Gu a de Investigaci n y Soluci n de Fallas e Siempre mantenga con l quido el tanque de la bomba No es necesaria m s lubricaci n en el extremo de la bomba y en el sello Si el flujo no inicia dentro de los primeros cinco minutos detenga el motor y determine la causa vea la Gu a de Investigaci n y Soluci n de Fallas Aseg rese de que todas las v lvulas de descarga y de succi n est n abiertas cuando la bomba se est cebando La operaci n de la bomba con una v lvula cerrada en el sistema la puede da ar ROTACI N e Su bomba ha sido dise ada espec ficamente para girar como lo indica la flecha en el tanque de la bomba Los motores trif sicos pueden girar en cualquier direcci n por lo tanto verifique la rotaci n Puede invertir la ro taci n al intercambiar cualquier par de cables del motor trif sico si fuera necesario ALMACENAMIENTO DE INVIERNO e Con temperaturas ambientales bajo cero e
6. les orifices d aspiration et de refoulement de la pompe pour prot ger celle ci des contraintes 3 Tout le mat riel lectrique doit tre connect par un lectricien selon le code provincial ou national de l lectricit pertinent et les r glements locaux Tous les moteurs n cessitent un d marreur magn tique avec protection contre les surcharges 4 On ne peut modifier la pompe y ajouter des l ments ni en enlever sans avoir obtenu l approbation de Pusine cette fin 5 Si des ondes de choc peuvent se propager dans le syst me on doit poser des protections clapets de non retour robinets vannes etc sur le tuyau de refoulement pour emp cher les coups de b lier de parvenir au corps de pompe 6 On ne peut amorcer une pompe dont le tuyau de refoulement est bloqu par des appareils ferm s du genre clapet de non retour robinet vanne etc Voir ce que ces appareils soient ouverts avant l amorcage Si de Pair peut s accumuler dans le corps de pompe poser un purgeur d air automatique 7 Les 20EVP sont con ues principalement pour le pompage de l eau Avant de les utiliser pour d autres liquides lire attentivement la mise en garde ATTENTION ci dessous 8 La surchauffe de la pompe est surtout due l arr t de la circulation du liquide dans les tuyaux aspiration et refoulement Elle est dangereuse elle peut g n rer de la vapeur causer des br lures et provoquer une explosion S il
7. n mero de modelo y n mero de serie de su bomba que se localizan en la placa de datos de la misma 17 12 14 NOTAS 15 GARANT A LIMITADA DE GOULDS WATER TECHNOLOGY Esta garant a es aplicable a todas las bombas para sistemas de agua fabricadas por Goulds Water Technology Toda parte o partes que resultaren defectuosas dentro del per odo de garant a ser n reemplazadas durante dicho per odo de garant a sin cargo para el comerciante Tal per odo de P P q P 8 P P 8 80 p p garant a se extiende por doce 12 meses a partir de la fecha de instalaci n o dieciocho 18 meses a partir de la fecha de fabricaci n la que se cumpla primero El comerciante que considere que existe lugar a un reclamo de garant a deber ponerse en contacto con el distribuidor autorizado de Goulds Water Technology del cual adquiriera la bomba y brindar informaci n detallada con respecto al reclamo El distribuidor est autorizado a liquidar todos los reclamos por garant a a trav s del Departamento de Servicios a Clientes de Goulds Water Technology La presente garant a excluye a La mano de obra el transporte y los costos relacionados en los que incurra el comerciante b los costos de reinstalaci n del equipo reparado c los costos de reinstalaci n del equipo reemplazado d da os emergentes de cualquier naturaleza y e el reembolso de cualquier p rdida causada por la interrupci n del servicio A los fines de esta ga
8. par de conductores para invertir la rotaci n Operaci n ruidosa Cojinetes del motor gastados Presi n est tica de descarga baja Basura atorada en el impulsor Cavitaci n Reemplace Reducir el flujo descarga Desensamble la bomba y l mpiela Mejore las condiciones de succi n 13 LISTA DE PARTES DE REPUESTO Clave Descripci n Clave Descripci n 1 Tap n de drenaje 110 Conjunto de sello 2 Cubierta 12 Tanque 30 Junta cubierta 130 Calza motor 40 Tuerca del impulsor 140 Chaveta del impulsor 50 Arandela del impulsor 15 Tornillo 69 Impulsor 16 Tornillo 70 Difusor 170 Eslingador 80 Junta difusor 18 Codo 90 Impulsor calza 19 Tap n del filtro 100 Impulsor espaciador 20 Motor Partes de repuesto recomendadas Partes que se le recomienda al distribuidor tener en existencia partes de exportaci n y partes cr ticas para el servicio IMPORTANTE C mo usar el dibujo para solicitar partes de repuesto Las ilustraciones anteriores de grupos de partes cubren diferentes modelos de Goulds Water Technology incluyendo la bomba de usted La tabla en la p gina izquierda indica el nombre de cada parte Si necesitara cambiar una de ellas consulte el dibujo y localice la parte que coincida con la parte de su bomba Contacte a su distribuidor local de Goulds Water Technology y d le el n mero de clave y descripci n de las partes que requi era junto con el
9. pump 9 Drain casing completely when servicing pumps han dling volatile or harmful liquids 10 Do not use in a combustible atmosphere 11 Make daily checks of the tightness of suction and discharge pipe drain filter plug and pump gaskets Operation should not proceed until all of the above items have been checked and are tight 12 After servicing the pump always install the coupling guards belt guards and other safety devices as origi nally found prior to disassembly The performance of Goulds Water Technology are based upon clear cold fresh water with suction conditions as shown on the performance curve If used to pump other liquids pump performance may differ from rated performance based on the different specific gravity temperature viscosity etc of the liquid being pumped A standard pump may not be safe for pumping all types of liquids such as toxic volatile or chemical liquids or liquids under extreme temperatures or pressures Please consult your Goulds A CAUTION Water Tehcnology catalog as well as local codes and general references to determine the appropriate pumps for your particular application Since it is impossible for us to anticipate every application of a Goulds Water Tehcnology pump if you plan to use the pump for a non water application consult Goulds Water Tehcnology beforehand to determine whether such application may be proper or safe under the circumstances Failure to do so could resul
10. resultar de problemas el ctricos o mec nicos como voltaje bajo mala ventilaci n l neas con exceso de carga etc Estos motores arrancar n de nuevo de manera autom tica cuando su temperatura baje a cierto valor Por seguridad no trabaje en el motor sin primero desconectar el suministro el ctrico de la fuente mencionada antes en la ADVERTENCIA Tambi n todos los motores trif sicos no tienen protecci n t rmica y se recomienda poner ar rancadores de motor INSTRUCCIONES PARA ELECTRICISTAS CON LICENCIA APAGAR 1 Determine el voltaje de la l nea de alimentaci n el ctrica al motor El voltaje fase salida de amperes y ciclos se indican en la placa de datos del motor El cable que se usa para alimentar al motor debe ser lo suficientemente grueso para los amperes y la longitud que se requiere sin que se produzca una ca da excesiva de voltaje La siguiente tabla pretende ser s lo una gu a para la selecci n de los tama os m nimos apropiados de cable Consulte siempre los c digos el ctricos locales Tama os t picos de cable AWG para motores monof sicos de bombas HP Longitud del cable 50 pies Longitud del cable 100 pies 115V 230 V 115 V 230 V 14 12 Y 14 14 10 14 Y 12 14 10 14 1 12 14 8 14 1 10 14 8 12 2 8 12 8 12 GU A DE SOLUCI N DE FALLAS Las siguientes son algunas causas comunes de problemas que pueden surgir S NTOMAS No se ceba Deja de bomb
11. y a surchauffe 1 arr ter la pompe 2 la laisser refroidir 3 en purger la vapeur lentement et avec pr caution 9 Si la pompe contient des liquides volatiles ou dange reux la vidanger avant d en effectuer l entretien 10 Ne pas utiliser la pompe en milieu combustible 11 V rifier journellement l tanch it de la tuyauterie des bouchons de vidange de l vent filtre et des joints de la pompe Ne pas mettre celle ci en mar che tant que la v rification en question n a pas t effectu e 12 Apr s l entretien de la pompe il faut reposer le carter d accouplement le prot ge courroie et les autres pro tections d origine install s avant le d montage Les performances des pompes Goulds sont bas es sur le pompage d eau douce limpi de et froide dans les conditions d aspiration figurant dans les courbes de performances Avec les autres liquides les performances peuvent varier compte tenu de la densit de la temp rature et de la viscosit du liquide L usage d une pompe standard peut tre risqu si le liquide est tr s chaud toxique volatile d origine chimique ou sous une tr s forte pression Il vaut mieux consulter le catalogue Goulds Water Technology ainsi que les codes locaux et les ouvrages de r f rence g n raux pour s lectionner la pompe convenant un usage particulier Goulds Water Technology ne peut pr voir tous les usages faits de ses pompes Il est donc
12. INSTRUCTION MANUAL IMO78 Retain Manual for Reference Marlow Series 20EVP INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS g GOULDS a xylem brand Table of Contents SUBJECT PAGE Recommended Pr cautions steam dalt 3 Operating Instrueti ns a sr near A esse etvsenkdssesss EERE p ENE PAE eSEE E EEE EEE EAER ERSEN 3 Operativa 4 PE A da 4 Rota estadia da 4 Winter LOT Rd nn Ferse 4 ubrication ini NN MR AIN das Maint nance viii in did did test svcd che ONS ie A dits resta 4 NA cernes era rinenssennne E etre et din sn etre nee sDn ns dns einen et ane eut TER eu tte TEE E 4 NO 4 Histructions for Licensed Electricians en lidad ATEA E dadas 4 Troubleshooting Guide comarca tit n da 5 Repair Parts nennen A ti 6 Limited Warran y er E E et de den E dette ere man E de et E E E EE 8 Owner s Information Please fill in data from your pump nameplate Warranty information is on page 8 Pump Model Serial Number Dealer Dealer s Phone Number Date of Purchase Installation Date CONGRATULATIONS You are now the owner of a Goulds Water Technology pump This pump was carefully inspected and subjected to final tests before releasing for shipment In order to assure maximum performance please follow the simple instructions in this manual RECOMMENDED PRECAUTIONS 1 Avoid system pressures that may exceed the maxi mum working pressure of the pump 2 Should the fluid temperature ri
13. Mars 2012
14. NOMALIES Ci dessous on trouvera certaines causes d anomalies communes ANOMALIES La pompe ne s amorce pas CAUSES PROBABLES Liquide absent du corps de pompe Air entrant dans la tuyauterie d aspiration Tuyauterie d aspiration bouch e Garniture m canique us e CORRECTIFS RECOMMAND S Remplir la pompe de liquide Serrer tous les joints ou les refaire avec de la p te joint neuve Nettoyer la cr pine ou la tuyauterie d aspiration Remplacer la garniture Le liquide s arr te sou dainement de s couler Cr pine ou roue engorg e Clavette de roue manquante ou bris e Enlever les r sidus Poser ou remplacer la clavette Le liquide s arr te lentement de circuler Roue diffuseur ou conduites engorg s bouchon de remplissage mal serr Enlever les r sidus utiliser une cr pine resserrer le bouchon Hauteur d aspiration excessive Air entrant dans la tuyauterie d aspiration Trop de liquide sort Garniture m canique us e Remplacer la garniture par l orifice de fuite La pompe se Garniture m canique us e Remplacer la garniture d samorce Rapprocher la pompe de sa source de liquide Colmater la fuite Le rendement est faible Roue ou garniture m canique us e Hauteur d aspiration excessive Poser une roue ou une garniture neuve Rapprocher la pompe de sa source de liquide Le d bit ou la pression est faible Moteur trop lent basse tension Ai
15. d in impeller Cavitation Larger lead wires Tighten all joints or remake using new compound Clean strainer or suction line Install new seal Interchange any two leads to reverse the rotation Replace Throttle discharge Disassemble pump and clean out Improve suction conditions REPAIR PARTS LIST Key Description Key Description Drain plug 110 Seal assembly 2 Cover 12 Tank 30 Gasket cover 130 Shim motor 40 Impeller nut 140 Impeller key 50 Impeller washer 15 Cap screw 69 Impeller 16 Cap screw 70 Diffuser 170 Slinger 80 Gasket diffuser 18 Elbow 90 Impeller shim 19 Filler plug 100 Impeller spacer 20 Motor Recommended spare parts Recommended distributor stock export spares and critical service IMPORTANT How to use the drawing to order parts The above grouping of parts illustrations cover many different Goulds Water Technology models including your own pump The table on the left page indicates the name of each part Should you need a replacement refer to the drawing locate the part that matches your pump part Contact your local Goulds Water Technology dealer and supply him with the key number and description of the parts required along with your pump model number and serial number which are located on the pump nameplate NOTES GOULDS WATER TECHNOLOGY LIMITED WARRANTY This warranty applies to all water systems pumps man
16. de r installation du mat riel de remplacement d les dommages indirects de quelque nature que ce soit e ni les pertes d coulant de la panne Aux fins de la garantie les termes ci dessous sont d finis comme suit 1 Distributeur signifie une personne une soci t de personnes une soci t de capitaux une association ou autre entit juridique servant d interm diaire entre Goulds Water Tech nology et le d taillant pour les achats les consignations ou les contrats de vente des pompes en question 2 D taillant veut dire une personne une soci t de personnes une soci t de capitaux une association ou autre entit juridique dont les activit s commerciales sont la vente ou la location de pompes des clients 3 Client d signe une entit qui ach te ou loue les pompes en question chez un d taillant Le client peut tre une personne une soci t de personnes une soci t de capitaux une soci t responsabilit limit e une association ou autre entit juridique se livrant quelque activit que ce soit LA PR SENTE GARANTIE SE RAPPORTE AU D TAILLANT SEULEMENT Xylem nn 1 2881 East Bayard Street Ext Suite A Rete note Water Seneca Falls NY 13148 T l phone 800 453 6777 T l copie 888 322 5877 www xyleminc com brands gouldswatertechnology Goulds est une marque d pos e de Goulds Pumps Inc et est utilis sous le permis 2012 Xylem Inc 1M078 R vision num ro 4
17. ear repentinamente CAUSA PROBABLE No hay l quido Hay fuga de aire en la l nea de succi n L nea de succi n obstruida Sello gastado Colador o impulsor atorado Chaveta del impulsor perdida o rota ACCION QUE SE RECOMIENDA Llene el tanque con l quido Apriete todas las juntas o col quelas de nuevo usando un compuesto nuevo Limpie el colador o la l nea de succi n Instale un sello nuevo Quite la basura Reemplace Deja de bombear paulatinamente Impulsor difusor o l neas obstruidas o tap n de relleno suelto Quite la basura y use un colador apriete el tap n de relleno Fuga excesiva en el sello de la ventilaci n del pozo Sello gastado Reemplace el sello No mantiene la bomba cebada Sello gastado Elevaci n de succi n muy alta Fuga de aire en la l nea de succi n Reemplace el sello Reubique la bomba m s cerca del suministro Escape del arreglo Pobre desempe o Sello o impulsor gastado Elevaci n de succi n muy alta Reemplace el sello o impulsor por uno nuevo Reubique la bomba m s cerca del suministro Flujo o presi n bajos El motor no alcanza la velocidad voltaje bajo Fuga de aire L nea obstruida Sello gastado Rotaci n incorrecta motor trif sico Alambres conductores m s largos Apriete todas las juntas o reinst lelas usando compuestos nuevos Limpie el colador o la l nea de succi n Instale un sello nuevo Intercambie cualquier
18. entre la pompe et le robinet vanne e Une pression de refoulement faible peut faire augmen ter le bruit de la pompe Fermer alors graduellement le robinet vanne du tuyau de refoulement jusqu ce que le bruit excessif disparaisse Cette restriction ne causera pas de perte de d bit appr ciable UTILISATION AMOR AGE e Remplir le corps de pompe de liquide avant la mise en marche Le bouchon du coude fix au corps de pompe sert cela Enduire les filets du bouchon avec de la p te joint avant de le visser sur le coude La pompe autoamor ante Goulds s amorce d elle m me si elle est remplie de liquide En cas de vidange accidentelle ou intentionnelle de la pompe la remplir avant de la remettre en marche Une hauteur d aspiration et une tuyauterie d aspiration de grande dimension requi rent un temps d amor age plus long et r duisent le rende ment de la pompe En cas de probl me voir Diagnostic des anomalies Veiller ce qu il y ait toujours du liquide dans la pompe pour en assurer la lubrification et celle de la garniture m canique Aucune autre forme de lubrification n est n cessaire Si le d bit ne devient pas r gulier apr s cinq minutes d essai d amor age consulter le Diagnostic des anomalies S assurer que les robinets d aspiration et de refoulement sont ouverts durant l amor age et ce afin de ne pas endommager la pompe SENS DE ROTATION La pompe est con ue pour tourner dans le sens indiqu sur le cor
19. es STRAINER ADVISABLE e Protect your investment Install a strainer on the suc tion line This will eliminate clogging of the pump poor performance and excessive wear A 16 mesh strainer submerged one foot below the liquid level is adequate for EV series pumps In line strainers are available from your Goulds Water Technology dealer Piping that has a continuous rise will facilitate draining the system VALVES e Install a check valve on the discharge side of the pump This will prevent high surge back pressures from damaging the pump If the pump is disconnected this check valve will prevent the liquid from draining the discharge line e Some installations may require the throttling of the pump Gate valves may be used on the discharge side Place the check valve between pump and gate valve e If the pump is operated against a low discharge pres sure it may be noisy Throttle down the discharge gate valve until the noise is eliminated This restriction will not cause any appreciable loss in capacity OPERATING PRIMING e Fill the pump tank with liquid before starting This may be done through the elbow on the side of the tank Use pipe compound when replacing the plug in the side elbow These Goulds Water Technology prime and reprime themselves providing the pump tank is filled with liquid Should you lose this liquid from the tank accidentally or by draining purposely it will be neces sary to refill it with liquid before
20. es Utiliser de la p te joint que le liquide pomper ne pourra dissoudre L usage de robinets van nes et de raccords unions ou de brides de chaque c t de la pompe facilitera la d pose de celle ci et ce sans d placer la tuyauterie Il est parfois avantageux d em ployer un tuyau d aspiration du calibre imm diatement sup rieur celui de l orifice d aspiration de la pompe Utiliser un raccord r ducteur excentr pour changer le calibre de la tuyauterie CR PINE RECOMMAND E e Prot ger son investissement en installant une cr pine l entr e du tuyau d aspiration On vitera ainsi l engor gement le rendement m diocre et l usure excessive de la pompe Une cr pine de 16 mailles par pouce immer g e un pied de profondeur convient aux pompes de la s rie EV On peut se procurer les cr pines chez le d taillant Goulds Water Technology La tuyauterie inclin e graduellement vers le haut partir de la source de liquide facilite la vidange du syst me APPAREILS DE ROBINETTERIE e Poser un clapet de non retour du c t refoulement de la pompe pour emp cher les coups de b lier d endom mager la pompe et emp cher aussi la tuyauterie de refoulement de se vider durant la d pose de la pompe 19 e Certaines installations peuvent n cessiter l trangle ment de la section de passage du c t refoulement de la pompe On peut employer des robinets vannes cette fin En pareil cas poser le clapet de non retour
21. n de la garant a est en la p gina 16 N mero de modelo de la bomba N mero de serie Distribuidor Tel fono del dist Fecha de compra Fecha de instalaci n 10 PAGINA FELICIDADES Ya es usted el propietario de una bomba Goulds Water Technology Esta bomba se inspeccion cuidadosamente y se sujet a las pruebas finales antes de liberarla para su embarque Para asegurar un desempe o m ximo por favor sigua las instrucciones de este manual PRECAUCIONES RECOMENDADAS 1 Evite presiones en el sistema que excedan la presi n m xima de trabajo de la bomba 2 Si la temperatura del fluido se eleva a m s de 50 F por encima de la temperatura ambiente se deben instalar las juntas de expansi n tanto en el puerto de succi n como en el de descarga para liberar cualquier tensi n de la carcasa de la bomba Un electricista autorizado deber realizar todo el cableado el ctrico de la instalaci n de la bomba de conformidad con todos los c digos nacionales y locales de electricidad Todos los motores el ctricos requieren de un arrancador magn tico con protec ci n de sobre carga de corriente ics gt No se deben hacer modificaciones anadiduras ni omisiones a la bomba sin la aprobaci n previa de la f brica 5 En los sistemas en los que pueda generarse una pre si n de ondas de choque se deben instalar dispositi vos de protecci n en la l nea de descarga tales como v lvulas de re
22. nimum proper wire size selection Always consult local electri cal codes Typical AWG Wire Size for Single Phase Jet Pump Motors HP 50 Ft Wire Length 100 Ft Wire Length 115V 230 V 115V 230 V 14 12 Y 14 14 10 14 Y 12 14 10 14 1 12 14 8 14 1 10 14 8 12 2 8 12 8 12 TROUBLESHOOTING GUIDE The following are some common causes of problems that may arise Suction lift too high Air leak in suction line SYMPTOMS PROBABLE CAUSE RECOMMENDED ACTION Will Not Prime No liquid Fill tank with liquid Air leak in suction line Tighten all joints or remake using new compound Blocked suction line Clean strainer or suction line Worn seal Install new seal Suddenly Stops Clogged strainer or impeller Clean debris Pumping Missing or broken impeller key Replace Slowly Stops Clogged impeller diffuser lines or loose Clean debris and use strainer Tighten filler Pumping filler plug plug Excessive Leakage Worn seal Replace seal From Seal Well Vent Will Not Worn seal Replace seal Hold Prime Relocate pump closer to supply Fix leak Performance Poor Worn impeller or seal Suction lift too high Replace with new impeller or seal Relocate pump closer to supply Low Flow Or Pressure Noisy Operation Motor not up to speed low voltage Air leak Blocked line Worn seal Incorrect rotation three phase motor Worn motor bearings Low discharge head Debris lodge
23. nt prot g s contre les surcharges thermiques et s arr tent lorsqu il y a surchauffe d origine m canique ou lectri que telle qu une mauvaise ventilation une basse tension un c blage surcharg etc Ils red marrent inopin ment quand ils se refroidissent Pour des raisons de s curit ne travailler sur aucun moteur sans que le courant soit d abord coup la source Proc der alors selon 1 AVER TISSEMENT pr c dent Les moteurs triphas s n ont pas de protection thermique Un d marreur est recom mand dans leur cas DIRECTIVES POUR LES LECTRICIENS COUPER LE COURANT 1 D terminer la tension sur les fils d alimentation du moteur Tension nombre de phases d bit en amp res et fr quence du courant figurent sur la plaque signa l tique du moteur Le calibre des fils d alimentation du moteur doit tre suffisamment gros pour transporter le courant sur la longueur de c ble requise sans chute de tension excessive La table suivante sert de guide uniquement pour le choix du calibre de fil minimal appropri Il faut toujours consulter le code provincial ou national de l lectricit pertinent et les r glements locaux Calibre de fil AWG type des moteurs de pompe jet monophas s h Longueur de fil de 50 pi Longueur de fil de 100 pi P 115V 230V 115V 230V 14 12 Y 14 14 10 14 Ya 12 14 10 14 1 12 14 8 14 1 10 14 8 12 2 8 12 8 12 DIAGNOSTIC DES A
24. ps de pompe Comme les moteurs triphas s peuvent tourner dans les deux sens v rifier leur sens de rotation et au besoin l inverser en intervertissant deux des fils de moteur ENTREPOSAGE HIVERNAL e Par temps de gel il est particuli rement important que le corps de pompe soit enti rement vidang pour en pr venir l endommagement et celui des pi ces internes e Afin de maintenir l excellent rendement de la pompe suivre les directives du fabricant du moteur quant l entreposage LUBRIFICATION e La garniture m canique autolubrifiante est le fruit des derniers progr s techniques tant donn que le liquide pomp refroidit et lubrifie la garniture la pompe ne doit jamais fonctionner sec L orifice de fuite du logement de garniture prot gera le moteur lectrique du liquide s il y a fuite de la garniture NE PAS boucher Porifice Si la garniture fuit trop la remplacer 20 ENTRETIEN e Si la pompe n est pas employ e pendant quelques jours la vidanger pour pr venir la formation de rouille aggravante et co teuse Un lectricien doit r aliser tout le mon tage lectrique S assurer que le courant est coup la bo te de jonction secteur avant de tra vailler sur la pompe ou le moteur Mettre le fusible ou le disjoncteur hors circuit et poser sur l interrupteur secteur une tiquette disant Ne pas r tablir le courant tra vaux en cours sur le mat riel arrennion Certains moteurs so
25. r aspir dans les conduites Conduite engorg e Garniture m canique us e Mauvais sens de rotation moteur triphas Employer un calibre de fil d alimentation plus gros Serrer tous les joints ou les refaire avec de la p te joint neuve Nettoyer la cr pine ou la tuyauterie d aspiration Remplacer la garniture Intervertir deux des fils d alimentation du moteur Le bruit de fonctionnement est lev Roulements ou coussinets de moteur us s Hauteur de refoulement faible R sidus accumul s dans la roue Cavitation Les remplacer trangler la section de passage du tuyau de refoulement D monter et nettoyer la pompe Am liorer les conditions n cessaires pour l aspiration 21 LISTE DE PIECES DE RECHANGE N Description N Description Bouchon de vidange 110 Garniture m canique 2 Couvercle corps de pompe 12 Corps de pompe 30 Joint d tanch it couvercle 130 Cale moteur 40 crou de roue 140 Clavette roue 50 Rondelle de roue 15 Vis d assemblage 69 Roue 16 Vis d assemblage 70 Diffuseur 170 D flecteur de liquide 80 Joint d tanch it diffuseur 18 Coude 90 Cale roue 19 Bouchon de remplissage 100 Entretoise roue 20 Moteur O Pieces de rechange recommand es Service critique pieces de rechange pour l exportation et stocks du distributeur recommand s IMPORTANT Mode de commande des pieces
26. rant a los t rminos Distribuidor Comerciante y Cliente se definen como sigue 1 Distribuidor es aquel individuo sociedad corporaci n asociaci n u otra entidad jur dica que opera entre Goulds Water Technology y el comerciante para la compra consig naci n o contratos de venta de las bombas en cuesti n 2 Comerciante es todo individuo sociedad corporaci n asociaci n u otra entidad jur dica que realiza negocios de venta o alquiler venta leasing de bombas a los clientes 3 gt Cliente es toda entidad que compra o adquiere bajo la modalidad de leasing las bombas en cuesti n de un comerciante El t rmino cliente puede significar un individuo sociedad corporaci n sociedad de responsabilidad limitada asociaci n o cualquier otra entidad jur dica con actividades en cualquier tipo de negocios LA PRESENTE GARANT A SE EXTIENDE AL COMERCIANTE NICAMENTE xylem nn 1 2881 East Bayard Street Ext Suite A Reve note Water Seneca Falls NY 13148 Tel fono 800 453 6777 Fax 888 322 5877 www xyleminc com brands gouldswatertechnology Goulds es una marca registrada de Goulds Pumps Inc y se utiliza bajo licencia 2012 Xylem Inc IM078 Revisi n N mero 4 Marzo 2012 MANUEL D UTILISATION IMO78 conserver titre consultatif Marlow s rie 20EVP DIRECTIVES D INSTALLATION D UTILISATION ET D ENTRETIEN g GOULDS a xylem brand Table des mati res SUJET
27. recommand de s adresser Goulds Water Technology si l on pr voit utiliser une pompe pour un liquide autre que l eau et ce afin de savoir s il y a risque ou non L inobservation de cette recommandation pourrait entra ner des blessures et des dommages mat riels DIRECTIVES D UTILISATION G N RALIT S Notre emballage est con u pour pr venir les dommages durant le transport Toutefois il faut noter toute indi cation d endommagement avec soin sur le bordereau de livraison et effectuer une demande de r glement sans tarder aupr s du transporteur LIEU D INSTALLATION APPROPRI e La pose de la pompe Goulds sur un massif de b ton solide et de niveau ou entre deux conduites solidement support es r duira les vibrations nuisibles et le bruit excessif e Bien que la pompe autoamorcante de la s rie EV puisse tre plac e plus haut que la source de liquide on obtiendra les meilleurs r sultats en l installant aussi pr s que possible du liquide pomper car elle refoule le liquide plus efficacement qu elle l aspire On pr voira suffisamment d espace autour de la pompe pour les inspections et l entretien de cette derni re TUYAUTERIE e La tuyauterie devrait poss der ses propres supports afin d liminer les contraintes excessives sur la pompe Pr venir les pertes de charge par frottement inu tiles Garder la tuyauterie aussi courte que possible et pourvue du minimum de coudes de raccords et d accessoir
28. s especial mente importante drenar todo el l quido del tanque de la bomba Esto evitar que el hielo que se puede formar rompa el tanque o partes internas e Para mantener un desempe o excelente de la bomba siga las instrucciones de almacenamiento del fabricante del motor 12 LUBRICACI N e Nuestro sello de eje autolubricante lleva los ltimos avances de la ingenier a El l quido que se va a bombear enfr a y lubrica el sello por lo tanto la bomba nunca deber operarse en seco Se ha proporcionado un sello bien ventilado para proteger el motor el ctrico de da os por el l quido que se pudiera fugar del sello NO TAPE esta ventilaci n Si la fuga es excesiva reemplace el conjunto del sello MANTENIMIENTO e Si la bomba no se va a usar por unos d as drene total mente el l quido esto evitar la oxidaci n la cual es grave y costosa A apvertenciA A apvertencia Todo el trabajo el ctrico lo debe hacer un electricista calificado Antes de tra bajar en los motores se debe tener la certeza de que el suministro de energ a est desconectado en la caja prin cipal de conexiones Desconecte el fusible o interruptor de circuito y ponga una etiqueta al interruptor principal con la leyenda No energizar este interruptor Personal trabajando en el equipo A precaucion Algunos motores est n equipados con sobrecargas t rmicas integradas para apagar el motor en el caso de un exceso de temperatura que puede
29. se more than 50 F above ambient expansion joints must be installed on both the suction and discharge ports to relieve any stress on the pump casing Qu All electrical wiring of the pump installation must be done by a licensed electrician who will observe all national and local electrical codes All motors require a magnetic starter with current overload protection 4 No modifications additions or deletions should be made to the pump without prior approval of the factory un In systems where shock wave pressures may be gener ated protective devices such as check valves gate valves etc must be installed on the discharge line to prevent shock pressures from entering the pump casing 6 In systems containing discharge check valves gate valves etc the pump will not prime against a closed valve Check the discharge valves making sure they are open before attempting to prime the pump If there is a possibility of air being entrapped in the pump casing install an automatic venting device to bleed off the air 7 This pump is designed primarily for water use Before pumping other liquids read carefully the CAUTION below ioe Overheated pumps are dangerous Burns or explosion could occur due to steam pressure Operating pumps with suction and discharge closed is one cause of se vere overheating If overheating of the pump occurs 1 Stop pump immediately 2 Allow pump to cool 3 Slowly and cautiously vent
30. spu s de dar servicio a la bomba siempre instale las guardas de acoplamiento guardas de bandas y otros dispositivos de seguridad como se encontraban originalmente antes del desensamble El desempe o nominal de las bombas Goulds Water Technology se basa en el bombeo de agua fresca fr a y transparente con las condiciones de succi n que se muestran en la curva de desempe o Si usa la bomba para otros l quidos el desempe o de la misma puede diferir del nominal en base a la diferencia de gravedad temperatura viscosidad etc Puede ser que una bomba est ndar no sea segura para bombear todos los tipos de l quidos como t xicos vol tiles o qu micos o l quidos bajo temperaturas o pre siones extremas Por favor consulte el catalogo de Goulds Water Technology as como c digos locales y referencias generales para determinar las bombas apropiadas para su aplicaci n en particular Ya que es imposible para nosotros anticipar cada apli caci n de una bomba Goulds si usted planea usarla para una aplicaci n que no sea agua consulte previamente a Goulds Water Technology para determinar si dicha apli caci n puede ser apropiada o segura seg n las circunstan cias No hacerlo puede resultar en da os a la propiedad o lesiones al personal INSTRUCCIONES DE OPERACI N GENERALIDADES e Nuestro contenedor de embarque se dise espec fica mente para evitar da os de transporte Sin embargo cualquier indicaci n de da o o fal
31. starting High suction lifts or long suction lines require additional time and reduce the performance of the pump Should you have difficulty refer to the Troubleshooting Guide Always keep liquid in the pump tank No further lubrication of the pump end is necessary including the seal assembly If flow does not start within five minutes stop the motor and determine cause see Trouble shoot ing Guide Be sure all suction and discharge valves are open when the pump is priming Operating the pump with a closed valve in the system can cause pump dam age ROTATION e Your pump is specifically designed to rotate as indicated by the arrow on the pump tank Three phase motors can rotate in either direction Check the rotation Inter changing any two leads of a three phase motor will reverse the rotation if this is found necessary WINTER STORAGE e During freezing weather it is especially important to drain all of the liquid from the pump tank This will prevent ice from cracking the tank or internal parts e To maintain the excellent performance of the pump fol low the motor manufacturer s storage instructions LUBRICATION The latest engineering advancements have been in corporated into our self lubricating shaft seal The liquid being pumped cools and lubricates the seal therefore the pump should never be run dry A seal well vent has been provided to protect the electric motor from liquid damage should the seal leak DO
32. t in property damage or personal injury OPERATING INSTRUCTIONS GENERAL e Our shipping container has been specifically designed to prevent transit damage However any indications of damage or shortage should be carefully noted on the delivery ticket and a claim filed promptly with the carrier PROPER LOCATION e By placing your pump on a firm level foundation or between firmly supported pipelines you reduce harm ful vibrations and unnecessary noises e While EV series pumps are self priming and may be located above the source of liquid supply best pump operation is obtained by locating the pump as close as possible to the liquid being handled keeping in mind a pump can push liquid more effectively than it can pull or draw liquid Provide the necessary space around the pump for future inspection and servicing of the unit PIPING e All piping should be independently supported to elimi nate excessive strain on the pump Avoid unnecessary friction losses Keep your piping as short as possible and use the fewest possible elbows and fittings Pipe joint compound that will not dissolve in the liquid being pumped should be used on all joints Gate valves combined with unions or flanges on both sides of the pump will facilitate pump removal without disturbing the piping It is occasionally advantageous to use suc tion pipe one size larger than that for which the pipe is fitted Eccentric reducers should be used to change pipe siz
33. tantes debe anotarse detalladamente en la nota de entrega y se debe envi arle de inmediato una reclamaci n correspondiente al transportista UBICACI N APROPIADA e Al colocar su bomba Goulds en una cimentaci n firme y nivelada o entre tuber as firmemente soportadas se reducen las vibraciones peligrosas y los ruidos innec esarios e Las bombas de la serie EV son de autocebadura y pueden colocarse por encima de la fuente de abastec imiento de l quido sin embargo el mejor funciona miento de la bomba se obtiene colocando la bomba tan cerca como sea posible del l quido que se va a manejar teniendo en cuenta que la bomba es m s efectiva en empujar un l quido que en succionarlo Considere el espacio necesario alrededor de la bomba para permitir inspeccionar y darle mantenimiento a la unidad TUBER A e Todas las tuber as se deben soportar de manera inde pendiente para eliminar cualquier exceso de tensi n en la bomba evitar las p rdidas de fricci n innecesarias mantener sus tuber as tan cortas como sea posible y minimizar el uso de codos y conexiones En todas las juntas se debe usar un compuesto que no se disuelva en el l quido que se bombea Las v lvulas de compuerta combinadas con uniones o bridas en ambos lados de la bomba facilitaran la remoci n de la misma sin alterar la tuber a El algunas ocasiones resulta ventajoso usar un tubo de succi n de un tama o m s grande que el ancho del tubo al que se va a conec
34. tar Se deben usar reductores exc ntricos para los cambios de di metro de la tuber a FILTRO RECOMENDABLE e Proteja su inversi n instale un filtro en la l nea de succi n Esto evitar que la bomba se atasque que el rendimiento baje y que se produzca un desgaste exce sivo Un colador de malla 16 sumergido un pie debajo del nivel del l quido es adecuado para las bombas de la Serie EV Puede conseguir coladores en l nea con 1 su distribuidor de Goulds Water Technology La tu ber a con una pendiente continua facilita el drenaje del sistema V LVULAS e Instale una v lvula de retenci n en el lado de descarga de la bomba para evitar que sta se da e por altas con trapresiones repentinas Si la bomba est desconectada est v lvula de retenci n evitar que se drene la l nea de descarga e Algunas instalaciones pueden necesitar que se reduzca el flujo a trav s de la bomba Para tal fin se pueden usar v lvulas de compuerta en el lado de descarga La v lvula de retenci n deber colocarse entre la bomba y la v lvula de compuerta e Si la bomba opera con una presi n de descarga baja puede producir mucho ruido Incremente la presi n por medio de la v lvula de compuerta de descarga hasta que se elimine el ruido Esta restricci n no causar ninguna p rdida apreciable de capacidad OPERACI N CEBADURA e Llene el tanque de la bomba con l quido antes del ar ranque para tal efecto puede usar el codo del
35. tenci n v lvulas de compuertas etc para evitar que las presiones de choque entren a la carcasa de la bomba 6 En los sistemas que contienen v lvulas de retenci n de descarga v lvulas de compuerta etc la bomba no se cebar contra una v lvula cerrada Verifique que las v lvulas de descarga est n abiertas antes de intentar cebar la bomba Si existe la posibilidad de que quede aire atrapado en la carcasa de la bomba instale un dispositivo de ventilaci n autom tico para purgar el aire 7 Esta bomba ha sido dise ada principalmente para manejar agua Antes de bombear otros l quidos lea cuidadosamente la siguiente PRECAUCI N 8 Las bombas sobrecalentadas son peligrosas La presi n del vapor podr a ocasionar quemaduras o explosi n Una causa de sobrecalentamiento grave en las bombas es la operaci n de las mismas con las tu ber as de succi n y descarga cerradas En caso de que la carcasa de la bomba se sobrecaliente 1 Detenga la bomba de inmediato 2 Permita que se enfr e 3 Vent lela despacio y con cuidado 9 Drene completamente la carcasa de la bomba cuando maneja l quidos vol tiles o peligrosos 10 No la use en atm sferas inflamables 11 Haga revisiones diarias de la hermeticidad de los tubos de descarga y de succi n drenaje tapones de filtro y juntas de la bomba No se deber proceder con la operaci n hasta que todos los puntos anteri ores se hayan revisado y est n correctos 12 De
36. ufactured by Goulds Water Technology Any part or parts found to be defective within the warranty period shall be replaced at no charge to the dealer during the warranty period The warranty period shall exist for a period of twelve 12 months from date of installation or eighteen 18 months from date of manufacture whichever period is shorter A dealer who believes that a warranty claim exists must contact the authorized Goulds Water Technology distributor from whom the pump was purchased and furnish complete details regarding the claim The distributor is authorized to adjust any warranty claims utilizing the Goulds Water Technology Customer Service Department The warranty excludes a Labor transportation and related costs incurred by the dealer b Reinstallation costs of repaired equipment c Reinstallation costs of replacement equipment d Consequential damages of any kind and e Reimbursement for loss caused by interruption of service For purposes of this warranty the following terms have these definitions 1 Distributor means any individual partnership corporation association or other legal relationship that stands between Goulds Water Technology and the dealer in purchases consignments or contracts for sale of the subject pumps 2 Dealer means any individual partnership corporation association or other legal relationship which engages in the business of selling or leasing pumps to customers