Express Ethernet Switch LGB316A-R2 LGB324A-R2
Contents
1. 10 100 1000Mbps 10Mbps Category 3 4 5 Utp STP copper 100Mbps Category 5 UTP STP 1000Mbps Category 5 5e UTP STP 1000Mbps Fiber 1000Mbps The cable type differs from the Mini GBIC mini GBIC you choose Please required refer to the instruction came with your mini GBIC Port Operation The auto negotiation feature allows ports running at one of the following operation modes 10 100 1000Mbps 10Mbps Full Duplex copper Half Duplex 100Mbps Full Duplex Half Duplex 1000Mbps Full Duplex 1000Mbps Fiber 1000Mbps Full Duplex mini GBIC required Note For the last port when both the fiber and cooper interfaces are connected the system adapts the fiber interface and disables the relevant cooper port automatically Backbone Network Application This switch is ideal for boosting the throughput of backbone For an application sample of network topology please refer to the following chart 100Mbps Hub L 100Mbps Switch d 1000Mbps File Web Server gt 1000Mbps File Web Server bea em Atco PC PC PC Express Ethernet Switch LGB316A R2 LGB324A R2 Product Specifications IEEE802 3 1OBASE T IEEE802 3u 100BASE TX IEEE802 3x full duplex flow control IEEE802 3z ab 1000BASE T 16 24 10 100 1000 Mbps auto MDI MDI X Interface RJ 45 switching ports 4 Mini GBIC module sockets RJ 45 10BASE T Category 3 4 5 UTP STP RJ 45 100BASE
2. radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE Mark Warning C This equipment complies with the requirements relating to electromagnetic compatibility EN 55022 class A for ITE the essential protection requirement of Council Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility Company has an on going policy of upgrading its products and it may be possible that information in this document is not up to date Please check with your local distributors for the latest information No part of this document can be copied or reproduced in any form without written consent from the company Trademarks All trade names and trademarks are the properties of their respective companies Copyright O 2006 All Rights Reserved Express Ethernet Switch LGB316A R2 LGB324A R2 Unpacking Information Thank you for purchasing th
3. TX Category 5 UTP STP RJ 45 1000BASE T Category 5 5e or enhanced UTP STP Fiber depend on Mini GBIC types Transmission 10 100Mbps Full duplex Half duplex Mode 1000Mbps Full duplex System LED Power indications 16 24 10 100M Link ACT 16 24 1000M Link ACT 8K MAC entries Memory 340K bytes Buffer Memory 16 Port 500K bytes Buffer Memory 24 Port FCC CE VCCI class A Operating 0 40 C 32 104 Temperature Operating E 10 90 non condensing Internal power supply Power Supply 100 240V 50 60 Hz universal input Standard Cable Connections
4. with Gigabit RJ 45 copper ports Express Ethernet Switch LGB316A R2 LGB324A R2 The Rear Panel Power Receptacle To be compatible with the electric service standards around the world the switch is designed to afford the power supply in the range from 100 to 240VAC 50 60Hz Please make sure that your outlet standard to be within this range To power on the switch plug the female end of the power cord firmly into the receptacle of the switch and the other end into an electric service outlet After the power cord installation please check if the power LED is illuminated for a normal power status Installation This switch can be placed on your desktop directly or mounted in a rack The installation is a snap Users can use all the features of the switch with simply attaching the cables and turning the power on Before installing the switch we strongly recommend 1 The switch is placed with appropriate ventilation environment A minimum 25mm space around the unit is recommended 2 The switch and the relevant components are away from sources of electrical noise such as radios transmitters and broadband amplifiers 3 The switch is away from environments beyond recommend moisture Desktop Installation 1 Attach the provided robber feet to the bottom of the switch to keep the switch from slipping The recommend position has been square marked 2 Install the switch on a level surface that can support the weight of th
5. 16 24 10 100 1000 Mbps RJ 45 Nway ports 4 Mini GBIC port for optional fiber optical communication Supports NWay protocol for speed 10 100 1000Mbps and duplex mode Half Full auto detection Supports MDI MDI X auto crossover Supports full and half duplex operation on all copper ports Supports back pressure half duplex and flow control IEEE 802 3x Wire speed packet filtering and forwarding rate Store and forward architecture Supports 9K bytes Jumbo frame Supports 8K bytes MAC address entries in whole system 340K 16 Port 1500K 24 Port bytes buffer memory Internal power adapter FCC VCCI CE Class A Meet RoHS Express Ethernet Switch LGB316A R2 LGB324A R2 The Front Panel The front panel consists of LED indicators For detailed LED definition please refer to the next paragraph LEDs Definition System LED Status Operation Steady Green The switch is powered on The switch is powered off Port LEDs Status Operation LED Steady Green Valid port connection at 1000 Mbps 1000M Biting Green Valid port connection and there is data transmitting receiving Off Port disconnected or the port is connected at 10 Mbps or 100 Mbps Valid port connection at 10 100 Steady Green Mbps 10 Valid port connection and there is 100M Pr In data transmitting receiving Port disconnected or the port is connected at 1000 Mbps a Attention The Mini GBIC slot shares the same LED 5 indicators
6. S BLACK BOX n NETWORK SERVICES Dec 2006 Express Ethernet Switch LGB316A R2 LGB324A R2 Order toll free in the U S Call 877 877 BBOX Outside U S call 724 746 5500 CUSTOMER FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax SUPPORT INFORMATION rod Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Express Ethernet Switch LGB316A R2 LGB324A R2 FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENT Class B Digital Device This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation However there is no guarantee that interference will not occur in a particular installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications If this equipment does cause harmful interference to radio or telephone reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separ
7. ation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult an experienced radio TV technician for help Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment To meet FCC requirements shielded cables and power cords are required to connect this device to a personal computer or other Class B certified device This digital apparatus does not exceed the Class B limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe B prescrites dans le R glement sur le brouillage radio lectrique publi par le minist re des Communications du Canada Normas Oficiales Mexicanas NOM INSTRUCCIONES DE SEGURIDAD 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben ser seguidas 5 El aparato el ct
8. e unit and the relevant components 3 Plug the switch with the female end of the provided power cord and plug the male end to the power outlet Rack mount Installation Rack mounting facilitate to an orderly installation when series of networking devices being installed The switch is supplied with rack mounting brackets and screws for rack mounting the unit Procedures to Rack Mount the Switch in the rack Disconnect all the cables from the switch before continuing Place the unit the right way up on a hard flat surface with the front facing you Locate a mounting bracket over the mounting holes on one side of the unit Insert the screws and fully tighten with a suitable screwdriver Repeat the two previous steps for the other side of the unit Insert the unit into the rack and secure with suitable screws optional Reconnect all the cables QUON or A Express Ethernet Switch LGB316A R2 LGB324A R2 Network Cables Installation 1 Crossover or straight through cable All the ports on the switch support Auto MDI MDI X functionality Both straight through or crossover cables can be used to connect the switch with PCs as well as other devices like switches hubs or router 2 Category 3 4 5 or 5e UTP STP cable To make a valid connection and obtain the optimal performance Appropriate cables corresponding to different transmitting receiving speed is required To choose a suitable cable please refer to the following table
9. iminada Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante En caso de existir una antena externa deber ser localizada lejos de las lineas de energia El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E El aparato ha sido tirado o su cubierta ha sido da ada Express Ethernet Switch LGB316A R2 LGB324A R2 FCC Certifications This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate
10. is product Before installation please verify that your package contains the following items 1 One 16 24 Port Gigabit Ethernet Switch with 4 Port Mini GBIC 2 One AC power cord 3 Rack mount brackets optional 4 User s Manual Introduction General Description Easily boost your networking throughput the product equips 16 24 Gigabit ports that lead you to a real Gigabit connection Users are now able to transfer large and high bandwidth needed files faster and hence get a real efficiency improvement In addition to the cooper ports 4 of the ports supports fiber connection with the equipped Mini GBIC ports for obtaining long distance communication This product offers users with fast and reliable network The store and forward architecture filters errors and forwards packets in a non blocking environment Flow control prevent data loss while transmitting The 802 3x and backpressure flow control mechanisms work respectively for full and half duplex modes The switch features with easy installation and maintenance It supports Nway auto negotiation protocol that detects the networking speed 10 100 1000 Mbps and the duplex modes Full Half automatically Auto MDI MDI X function alleviates the effort to use crossover cables Also rich diagnostic LEDs are provided for users to get real time information of the connection status Key Features Complies with IEEE802 3 IEEE 802 3u IEEE 802 3ab and IEEE 802 3z standards
11. rico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante Express Ethernet Switch LGB316A R2 LGB324A R2 10 11 12 13 14 15 16 17 18 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato Precauci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea el