1. 2 OPTIMUS INSTRUCCIONES DE FUNCIONAMIENTO GUIA DEL USUARIO OPERATING INSTRUCTIONS OWNER S MANUAL MD 20 PUPITRE MICROF NICO MICROPHONE DESK e Antes de hacer funcionar este aparato lea detenidamente estas instrucciones e Before operating this unit please read these instructions MD 20 UP MICROPHONE DESK ATENCI N WARNING Este es un equipo de Clase A En un ambiente dom stico This is a Class A product In a domestic environment this podr a llegar a causar radio interferencias En este caso product may cause radio interference in which case the el usuario deber a tomar las medidas adecuadas user may be required to take adequate measures CONTENIDO LIST OF CONTENTS 1 INTRODUCCI N aiii ED Re RH ERR MD c 3 1 INTRODUCTION eddie dd mendaci 2 PRESTACIONES india unde era cubus 3 2 FEATURES ditata bete tiae ers teat A CONTROLES andanada 4 Be CONTROLS dc 4 CONFIGURACI N cnc la 5 4 CONFIGURATION sis ici isentas adidas tu 5 CONEXIO NES 7 5 CONNECTIONS ali 6 FUNCIONAMENTO sicud rip cer bbs 7 B OPERATION siia ata cdi 7 EJEMPLOS DE CONEXI N 8 7 CONNECTION EXAMPLES 8 CARACTER STICAS T CNICAS csscssssessessesesseesesseseeees 9 8 TECHNICAL SPECIFICATIONS oooococccnicccninnnncnrnnoncnrnnos 9 GARANT A iia a 10 9 GUARANTEE iii iia MD 20 v1 2 DPVIMUS 2 1 INTRODUCCI N Este pupitre microf nico han sido dise ado para ser conectado a los preamplificadores y amplific
2. J3 TALK MODE J7 SHIELD GND LINK MD 20 v1 2 OPviMUs 6 OPVIMUS 5 CONEXIONES 5 1 SALIDA OUTPUT La salida de audio es balanceada con una sensibilidad configurable de OdB o 60dB a trav s de un conector RJ45 ver Fig 5 n 1 La funci n de los contactos del conector es la siguiente Pin 1 Salida de audio H Hot Pin 2 Salida de audio C Cold A trav s de los contactos 1 y 2 de este conector el micr fono puede recibir alimentaci n de tipo PHANTOM Pin 3 Entrada de alimentaci n los micr fonos admiten una tensi n de alimentaci n de 9 a 24 Vcc Pin 6 Salida control de prioridad Pin 8 GND masa 5 2 ENTRADA DE ALIMENTACI N Adem s de poder alimentar el micr fono a trav s del contacto 3 del conector RJ45 OUTPUT o a trav s de alimentaci n Phantom ver apartado 5 1 dispone de un conector de entrada para un alimentador externo de 9 a 24 Vcc ver Fig 5 n 2 6 FUNCIONAMIENTO Existen dos posibilidades de dar un aviso 1 Aviso con gong Se debe mantener pulsada la tecla GONG TALK hasta finaliza el aviso Durante la reproducci n del gong el Led se mantiene encendido en rojo y cambia a verde cuando el aviso ha finalizado indicando que se puede empezar a hablar 2 Aviso sin gong Se debe mantener pulsada la tecla TALK hasta finalizar el aviso El Led se mantiene encendido en verde mientras se est dando el aviso Adem s estos dos modelos ofrecen la posibilidad de configurac
3. 20 MD 20 RJ45 CONNECTOR MD 20 Addenda 0615 24VDC To amplifier POWER SUPPLY 1st in 1st CASCADE PRIORITY MODE PRIORITY MODE PRIORITY PRIORITY MPP 94 SELECTION SELECTION CONFIGURATION MD 20 P4 JUMPER OFF CONFIGURATION P4 JUMPER ON SAS REMOVE ALL UNITS OPVIMUS 87654321
4. configurar el nivel de salida a O dBm o a 60 dBm La configuraci n de f brica es a O dBm Puede cambiar el nivel de salida a 60 dBm mediante los puentes JP1 JP3 JP5 y JP6 ver Fig 4 4 2 COMPRESOR El puente J4 ver Fig 4 permite modificar la velocidad de desactivaci n del compresor 4 3 ENCLAVAMIENTO TALK MODE EI puente J3 permite configurar los pulsadores con enclavamiento hay que mantener pulsada la tecla GONG TALK o TALK hasta finalizar el aviso o sin enclavamiento hay que pulsar la tecla GONG TALK o TALK y una vez finalizado el aviso volverla a pulsar Configuraci n sin enclavamiento Situar el puente J3 en la posici n PUSH TO TALK ver Fig 4 Configuraci n con enclavamiento Situar el puente J3 en la posici n START AND STOP ver Fig 4 4 4 UNI N PANTALLA MASA El puente interno J7 permite separar la pantalla del cable RJ45 de la masa interna del aparato Por defecto la pantalla y la masa del aparato est n unidas puente colocado Para separarlas extraiga el puente J7 ver Fig 4 MD 20 v1 2 MD 20 PUPITRE MICROFONICO MICROPHONE DESK 4 CONFIGURATION It is reguired to access to the printed circuit in order to configure the desk To do so it is necessary to remove the three rubber bases and the screws A B and C as shown in figure 3 The following parameters can be configured e Output level configured ex factory 0 dBm see section 4 1 e Compressor release time config
5. other causes not attributable to OPTIMUS S A B The following elements are not covered by this guarantee All plastic surfaces and all parts exposed to outdoor conditions which have been scratched or damaged as a result of normal or abnormal use e Breakages knocks damage due to a fall or scratches caused by moving the unit in any way e Damage caused by tests use maintenance installation or inappropriate adjustments or as a result of any alteration or modification of any kind not carried out by a Service Authorized by OPTIMUS S A in compliance with this guarantee e Damage to persons or property that might be caused by the improper use of the equipment including lack of maintenance y The guarantee shall not be valid whenever the following is observed Amendments or corrections made to the details of the guarantee certificate or purchase invoice e Failure to produce the original invoice or the absence of a date on this e Absence of the serial or batch number on the equipment OPVI IMUS 10 OPVIMUS 6 Enelcaso de ordenadores P C la garant a no cubrir la eliminaci n de virus inform ticos restauraci n de programas por este motivo o la reinstalaci n del disco provocada por el borrado del mismo 7 Los derechos de garant a se anulan si el producto ha sido reparado o abierto por un personal no autorizado OPTIMUS S A o por el propio cliente 8 Sila empresa OPTIMUS S A estableciera al comprador del a
6. out correctly Nor shall OPTIMUS S A be responsible for any costs under this guarantee for these types of modifications 2 The guarantee shall not entitle the purchaser to inspection or free maintenance or repair of the unit particularly if the defects are due to inappropriate use Nor do the guarantee rights cover defects in wearing parts that become worn as a result of normal wear and tear Wearing parts are in particular potentiometers switches keys and similar parts 3 The guarantee does not cover defects in the equipment unit caused by e Abuseor incorrect use of the unit for purposes other than those for which it is intended in non compliance with the service and maintenance instructions specified in the Manual and or Technical Instructions for the unit e Connection or use of the product in a manner that does not correspond to the technical or safety requirements of the country in which the unit is used Installation in conditions other than those indicated in the Manual and or Technical Instructions e Deficiency or interruptions in the electricity supply or installation defects which imply use in abnormal conditions e Damage caused by other equipment units that are connected to the product e The use or installation of Software programmes interfaces parts or supplies not provided and or not authorized by OPTIMUS S A e Failure to use the original packaging for transportation e Damage caused by force majeure or
7. A 1 Si el producto tuviera que ser modificado o adaptado para cumplir con los requisitos locales en cuanto a t cnica o seguridad si no se trata del pa s para el cual el producto fue concebido y fabricado originalmente ello no se considera como defecto de material o de fabricaci n Por lo dem s la garant a no comprende la realizaci n de estas modificaciones o adaptaciones independientemente de si stas hayan sido ejecutadas debidamente o no OPTIMUS S A tampoco asumir costes en el marco de la garant a por este tipo de modificaciones 2 La garant a no dar derecho a inspecci n o mantenimiento gratuito o reparaci n del aparato particularmente si los defectos son debidos a uso inapropiado Los derechos de garant a tampoco abarcan defectos en piezas de desgaste que sean debidos a un desgaste normal Piezas de desgaste son en particular potenci metros interruptores teclas y piezas similares 3 La garant a no abarca los defectos en el equipo causados por e Abuso o uso incorrecto del aparato para fines distintos a los previstos en incumplimiento de las instrucciones de servicio y de mantenimiento especificadas en el Manual y o Instrucciones T cnicas del equipo e Conexi n o uso del producto de una manera que no corresponda a los requisitos t cnicos o de seguridad del pa s en el cual se utiliza el aparato Instalaci n en condiciones distintas a los indicados en el Manual y o Instrucciones T cnicas e Deficienc
8. CO MICROPHONE DESK 9 GUARANTEE 1 GUARANTEE CERTIFICATE 1 OPTIMUS S A guarantees that its products are free from material and manufacturing defects when they are first delivered to the purchaser 2 In accordance with the conditions outlined here OPTIMUS S A guarantees its products for two 2 years from the date on which the purchaser acquires the product If within this guarantee period defects appear which are not due to factors outlined in section 2 OPTIMUS S A shall replace or repair the unit using equivalent new or reconstructed replacement parts as it deems fit If replacement parts are applied which improve the unit OPTIMUS S A reserves the right to charge the client for the additional cost of these components 3 No guarantee benefits shall be provided other than those cited here 4 In order to claim the guarantee rights it shall be an essential requirement to present the original purchase invoice or the guarantee certificate 2 GUARANTEE PROVISIONS 1 In the event that the product had to be modified or adapted to comply with local requirements concerning technical specifications or safety and if the country in question is not the country for which the product was originally designed and manufactured defects are not considered to be material or manufacturing defects Furthermore the guarantee does not cover the execution of these modifications or adaptations regardless of whether or not they have been carried
9. DA En esta configuraci n la entrada del m dulo MPP 94 mas prioritaria es la 1 y la que tiene menor prioridad la 6 Cuando mas de un pupitre intenta enviar un mensaje el que est conectado a la entrada mas prioritaria es quien consigue enviar el mensaje Los pupitres de menor prioridad reciben la se al de ocupado led naranja encendido indicando que no pueden enviar avisos 1 IN 1 En esta configuracidn tiene prioridad el pupitre que antes se activa Los pupitres restantes reciben la sefial de ocupado led encendido naranja indicando que no pueden enviar avisos OUTPUT 1 To amplifier rear view front view MD 20 PUPITRE MICROFONICO MICROPHONE DESK CONNECTION EXAMPLES INSTALLATION WITH MPP 94 MODULE SEVERAL MD 20 WITH PRIORITY IN CASCADE OR FIRST IN FIRST AMONGST THE MICROPHONES CASCADE In this configuration the highest priority input module MPP 94 is the input 1 and the lowest priority is the input 6 When more than a desk trying to send a message which is connected to the highest priority input is who gets to send the message The lower priority desks receiving a busy signal orange LED lit indicating that they cannot send messages D IN q In this configuration overrides the desk that is active before The remaining desks receive a busy signal LED lit orange indicating that they cannot send messages OUTPUT 2 OUTPUT 6 MD
10. K 3 CONTROLS 1 LED indicator see Fig 1 n 1 The led keeps lighting in red colour while the gong is being generated and it changes to green colour when the gong is ended showing that you can start to talk 2 TALK KEY see Fig 1 n 2 It allows to send a message without gong signal 3 GONG TALK KEY see Fig 1 n 3 When pressing this key the desk generates the gong and you can start to talk 4 GONG VOLUME CONTROL see Fig 2 n 4 The volume of the gong can be attenuated by means of a potentiometer accessible from the lower side of the stand 5 MICRO VOLUME CONTROL see Fig 2 n 5 The volume of the micro can be attenuated by means of a potentiometer accessible from the lower side of the stand OP VIMUS 4 OPVIMUS 4 CONFIGURACION Para configurar el pupitre se debe acceder al circuito impreso Para ello deben quitarse los tres pies de goma y los tornillos A B y C tal y como indica la figura 3 A trav s de unos puentes internos pueden configurarse los siguientes par metros e Nivel de salida configuraci n de f brica O dBm ver apartado 4 1 e Velocidad de desactivaci n del compresor configuraci n de f brica 4400 milisegundos ver apartado 4 2 e Pulsador con enclavamiento configuraci n de f brica sin enclavamiento ver apartado 4 3 e Uni n pantalla masa configuraci n de f brica unidas ver apartado 4 4 4 1 NIVEL DE SALIDA OUTPUT LEVEL Es posible
11. LA GARANT A La garant a se concede nicamente para el comprador original cliente principal y es intransferible Con excepci n de la empresa OPTIMUS S A ning n tercero comerciantes etc est autorizado a conceder garant a adicionales en nombre de la empresa OPTIMUS S A 4 RECLAMACIONES POR DA OS Y PERJUICIOS En caso de que OPTIMUS S A no pueda proporcionar un servicio de garant a adecuado el comprador no tendr ning n derecho a reclamar indemnizaci n alguna por da os y perjuicios consecuentes La responsabilidad de la empresa OPTIMUS S A se limita en todo caso al precio de facturaci n del producto 5 RELACI N CON OTROS DERECHOS DE GARANT A Y CON EL DERECHO NACIONAL 1 Mediante esta garant a no se afecta a los derechos del comprador frente al vendedor deducidos del contrato de compraventa concluido 2 Las presentes condiciones de garant a de la empresa OPTIMUS S A son v lidas siempre que no contradigan el derecho nacional correspondiente en relaci n con las disposiciones de garant a 3 OPTIMUS S A asegura que este producto cumple con las normas de seguridad vigentes en el pa s ESTA DECLARACI N DE GARANT A LIMITADA ES LA GARANT A EXCLUSIVA OFRECIDA POR OPTIMUS S A SE EXCLUYE TODA OTRA GARANT A EXPL CITA O IMPL CITA INCLUIDAS LAS GARANT AS DE COMERCIALIDAD Y APTITUD A UN FIN DETERMINADO EXCEPTO CUANDO DICHAS GARANT AS SEAN REQUERIDAS POR UNA LEY APLICABLE NINGUNA GARANT A YA SEA EXPL CI
12. NE SENSITIVITY 47 dB 4 dB SENAL SALIDA 0 dB 1 V Pa 1 KHz 0 dB 1 V Pa 1 KHz GONG 4 Notas inicio GONG 4 Notes begin Flexo 250 mm Flexible support 250 mm i DIMENSIONS Pie 122 x 155 x 40 mm Stand 122 x 155 x 40 mm 1 4 kg WEIGHT 1 4 kg Pl stico Bayblend FINISHING Baybleng plastic MD 20 v1 2 OPviMUs 9 OPVIMUS 9 CONDICIONES DE GARANTIA 1 CERTIFICADO DE GARANTIA 1 La empresa OPTIMUS S A garantiza que sus productos se encuentran libres de defectos en materiales y de mano de obra en el momento de su entrega original al comprador 2 La empresa OPTIMUS S A concede a sus productos conforme a las condiciones aqu descritas una garant a de dos 2 a os a partir de la fecha de adguisici n del producto por el comprador Si dentro de este plazo de garantia se producen defectos gue no sean debidos a razones mencionadas bajo el punto 2 la empresa OPTIMUS S A reemplazar o reparar el aparato utilizando piezas de recambio eguivalentes nuevas o reconstruidas seg n criterio propio Si se aplican piezas de recambio gue constituyen una mejora del aparato la empresa OPTIMUS S A se reserva el derecho de cargar el coste adicional de estos componentes al cliente 3 Nose conceder n prestaciones de garant a distintas a las citadas 4 Para la utilizaci n de los derechos de garant a ser requisito indispensable presentar la factura de compra original o el certificado de garant a 2 DISPOSICIONES DE GARANT
13. TA O IMPL CITA SE APLICAR TRAS LA FINALIZACI N DEL PERIODO DE GARANT A OPTIMUS S A Servicio Post Venta C Barcelona 101 17003 GIRONA Tel 972 203 300 Fax 972 218 413 e mail girona optimus es 1999 44 CE MD 20 v1 2 MD 20 PUPITRE MICROFONICO MICROPHONE DESK 6 In the case of personal computers the guarantee will not cover the elimination of computer viruses the restoration of programmes damaged by these or the reinstallation of the disk following its deletion 7 The rights of this guarantee are invalidated if the product has been repaired or opened by staff unauthorized by OPTIMUS S A or by the client himself 8 If OPTIMUS S A were to establish before the client that the damage affecting the unit does not entitle a claim to be made under the guarantee the costs of checking the equipment incurred by OPTIMUS S A shall be borne by the client 9 Products not covered by the guarantee shall only be repaired once payment has been effected by the client In the event that the guarantee rights do not apply OPTIMUS S A shall duly inform the client If within a period of 6 weeks from this communication no written repair order is received from the client confirming acceptance of the costs OPTIMUS S A shall return the unit in question to the client In this case the transport and packaging costs shall be invoiced separately and payment shall be made on delivery In the event that a repair order is sent by the client c
14. act of sale accomplished 2 These conditions of the guarantee provided by OPTIMUS S A are valid as long as they do not contradict the corresponding national law on guarantee provisions 3 OPTIMUS S A guarantees that this product complies with the safety regulations in force in the country THIS LIMITED GUARANTEE DECLARATION IS THE EXCLUSIVE GUARANTEE OFFERED BY OPTIMUS S A ALL OTHER EXPLICIT OR IMPLICIT GUARANTEES ARE EXCLUDED AND THIS ALSO APPLIES TO GUARANTEES OF MARKETABILITY AND SUITABILITY FOR A PARTICULAR PURPOSE EXCEPT WHEN THESE GUARANTEES ARE REQUIRED BY AN APPLICABLE LAW NO GUARANTEE EITHER EXPLICIT OR IMPLICIT SHALL BE APPLIED ONCE THE GUARANTEE PERIOD HAS EXPIRED OPTIMUS S A After Sales Service C Barcelona 101 17003 GIRONA Tel 972 203 300 Fax 972 218 413 e mail girona optimus es 1999 44 CE OP VIMUS 11 Head Office 90000 SECURITY PAGING INFORMATION COMMUNICATION MUSIC V1 2 14 05 2015 C Barcelona 101 17003 Girona Spain O Y M S Tel 34 972 203 300 A SOUND amp COMMUNICATION e mail girona optimus es LITT TET IT LITT TT II 000001 o 3 E D c a o E 3 P C A 6 o gt vimus CONFIGURACION CONFIGURATION o P4 and R49 1st IN 1st CASCADE or ACK Fig 3 Fig 4 Factory setup PUSH FUNCIONAMIENTO EN MODO ACKNOWLEDGE ACK ACKNOWLEDGE ACK MODE OPERATION MD 20 O 3 connector SE PRI IN contact 5 or p
15. adores OPTIMUS y a los elementos de la serie 2600 de IMPROVE Dispone de un contacto de control de prioridad que activa las prioridades del sistema mientras se est generando un aviso Se puede alimentar mediante una fuente de alimentaci n externa de 9 a 24 Vdc o a trav s del conector RJ45 de salida 2 PRESTACIONES Micr fono electret con soporte flexible de 25 cm Gong de 4 notas Pulsador GONG TALK Pulsador TALK Pulsadores configurables electr nicamente con o sin enclavamiento Control de prioridad Led bicolor indicador GONG TALK Salida de audio a trav s de un conector RJ45 Alimentaci n de 9 a 24 Vdc a trav s del contacto n 3 del conector RJ45 o bien alimentaci n externa mediante una fuente de alimentaci n Permite tambi n alimentaci n Phantom de 24V a trav s del conector RJ45 entre terminales 1 y 2 Volumen de Gong Volumen de micr fono Nivel de salida configurable 0 dBm 60 dBm Salida balanceada electr nicamente MD 20 v1 2 MD 20 PUPITRE MICROFONICO MICROPHONE DESK 1 INTRODUCTION This microphone desk has been designed to be connected to the OPTIMUS amplifiers and preamplifier as well as to the IMPROVE 2600 series equipment It has a priority control contact which activates the priorities of the system while a message is being diffused It can be powered by a 9 to 24 Vdc external power supply source or by means of the output RJ45 connector 2 FEATURES Elect
16. ed until the message is ended The led keeps lighting in red colour while sending the message Furthermore these models offer the possibility to configure the lockable push button see section 4 3 In this case you must press the TALK key or GONG TALK to start talking and press it again once the message is ended OP VIMUS 7 MD 20 e NICROPHONE DESK OPVIMUS DC IN 9 24V OCO OUTPUT Pin number 1 AUDIO OUTPUT SIGNAL H Pin number 2 AUDIO OUTPUT SIGNAL C Pin number 3 24 VDC INPUT Pin number 6 PRIORITY CONTACT OUTPUT Pin number 8 Metal Shield Mu e amp e GND J7 internal jumper 7 EJEMPLOS DE CONEXION 7 CONNECTION EXAMPLES Fig 6 mur SE o PM 812 0 and C 810PRJ OUTPUT LEVEL OdBm IN ALL UNITS wm MD 20 OFF ON ON ON ON ON m 1 D 20 MD 20 attt SS C 810PRJ O PROGRAMMATION PRIORITY OdB and LOW IMPEDANCE MD 20 v1 2 OPviMUs 8 MD 20 UP MICROPHONE DESK UP 247 Fia 7 ig F A e 2 ade i gt 4 MD 20 AXD 30 60 120 240 Fig 8 o jo 00 28 ag Qu SET OUTPUT LEVEL TO 60dBm DIN 5 180 CONNECTOR RJ45 CONNECTOR 87654321 CONSUMO CONSUMPTION NIVEL SALIDA 6000 OUTPUT LEVEL 600 Q ANCHO DE BANDA FREQUENCY RESPONSE RELACI N SENAL RUIDO SIGNAL NOISE RATE IMPEDANCIA DE SALIDA OUTPUT IMPEDANCE 8 47 dB 4 dB MICROPHO
17. i n del pulsador con enclavamiento ver apartado 4 3 En este caso se debe pulsar la tecla TALK o GONG TALK para hablar y volver a pulsarla una vez finalizado el aviso MD 20 v1 2 MD 20 PUPITRE MICROFONICO MICROPHONE DESK 5 CONNECTIONS 5 1 OUTPUT The audio output is balanced with a configurable sensitivity of O dB or 60 dB via an RJ45 connector see Fig 5 No 1 The function of the contacts of the connector is the following Pin 1 Audio output signal H Hot Pin 2 Audio output signal C Cold Through contacts 1 and 2 of this connector the microphone can be powered by means of the PHANTOM technigue Pin 3 Power supply input the microphones allow a power supply voltage between 9 and 24 Vdc Pin 6 Priority control output Pin 8 GND ground 5 2 POWER SUPPLY INPUT Further to allow the reception of the reguired power supply voltage by means of the contact 3 of the RJ45 connector or through phantom power supply see section 5 1 the microphone is provided with an input connector for an external power supply between 9 to 24 Vdc see Fig 5 n 2 6 OPERATION There are two possibilities 1 Message with gong You must keep pressed the GONG TALK key until the message is ended While the gong is playing the led keeps lighting in red colour and it changes to green colour when the gong is ended indicating that you can start to talk 2 Message without gong It is reguired to keep the TALK key press
18. ia o interrupciones tensi n el ctrica o defectos de instalaci n que impliquen uso en condiciones anormales e Da os ocasionados por otros equipos interconectados al producto e El uso o instalaci n de Software programas interfaces partes o suministros no proporcionados y o autorizados por OPTIMUS S A e La no utilizaci n de los embalajes originales para su transporte e Da os causados por fuerza mayor u otras causas no imputables a OPTIMUS S A 4 No est n cubiertos por esta garant a los siguientes elementos e Todas las superficies de pl stico y todas las piezas expuestas al exterior que hayan sido rayadas o da adas debido al uso normal o anormal e Las roturas golpes da os por ca das o ralladuras causadas por traslados de cualquier naturaleza Defectos de da os derivados de pruebas uso mantenimiento instalaci n y ajustes inapropiados o derivados de cualquier alteraci n o modificaci n de cualquier tipo no realizada por en Servicio Autorizado por OPTIMUS S A en cumplimiento de esta garant a e Los da os personales o a la propiedad que pudieran causar el uso indebido del equipo incluyendo la falta de mantenimiento 5 La garant a carecer de validez cuando se observe e Enmiendas o tachaduras en los datos del certificado de garant a o factura de compra e Falta de factura original o falta de fecha en la misma e Falta de n mero de serie o lote en el equipo MD 20 v1 2 MD 20 PUPITRE MICROFONI
19. in 3 of RJ45 connector CASCADE TO TALK AND STOP J3 TALK MODE PRI OUT contact or pin 6 of RJ45 MD 20 alt rag REMOVE PUPITRE MICROF NICO MICROPHONE DESK JP5 JP1 JP3 JP6 AUDIO OUTPUT LEVEL UNLINKED LINKED J 7 J7 J7 SHIELD GND LINK J4 COMPRESSOR RELEASE TIME PRI OUT ACK t Pulsar el bot n Petici n de Procesando permiso TALK permiso El led tiempo requerido Push TALK se enciende para seleccionar button en naranja zonas aceptar TALK Asking for la llamadas so permission Permission processing Led lit in orange time reguired to select zones accept call MD 20 Addenda 0615 EXTERNAL EQUIPMENT PRI IN E Modo ACKNOWLEDGE Permite sincronizar el pupitre microf nico con elementos externos de activaci n de zonas evitando la perdida de se al inicial debido a 9 S LINEA DE posibles retardos en la gt TIEMPO activaci n Permiso para El led se TIME LINE hablar enciende en verde ACKNOWLEDGE mode PRE RR y se puede Allows to synchronize the to talk empezar a hablar microphone desk with When led is lit in green external elements of you can start talking zones activation to avoid the loss of initial signal due to possible delays in the activation O gt VIMUS 1 OPVIMUS EJEMPLOS DE CONEXION INSTALACION CON MODULO MPP 94 VARIOS MD 20 CON PRIORIDAD FIRST IN FIRST O CASCADE ENTRE PUPITRES CASCA
20. onfirming that he assumes the costs of repair the transport and packaging costs shall be invoiced additionally and also separately 10 If the equipment needs to be transferred to the Authorized Service Centre transportation shall be effected by the responsible party according to the guarantee who will also bear the freight and insurance costs 11 In the event of a defect OPTIMUS S A guarantees that the repair and or replacement of parts so that the unit operates correctly will be made within a period of no more than 30 days Nevertheless OPTIMUS S A would like to clarify that the normal period does not exceed 30 days 12 All parts or products replaced as part of the guarantee services shall become the property of OPTIMUS S A 3 TRANSFER OF GUARANTEE The guarantee is solely awarded to the original purchaser principal client and is not transferable With the exception of OPTIMUS S A no third party dealers etc is authorized to award additional guarantees on behalf of OPTIMUS S A 4 CLAIMS FOR DAMAGE In the event that OPTIMUS S A cannot provide a suitable guarantee service the purchaser shall not be entitled to claim any indemnity for damages arising The responsibility held by OPTIMUS S A is limited in all cases to the invoicing price of the product 5 RELATION WITH OTHER GUARANTEE RIGHTS AND NATIONAL LAW 1 This guarantee does not affect the rights of the purchaser with respect to the vendor arising from the contr
21. parato que los dafios presentados no dan derecho a la reclamacion de la garantia los costes de las prestaciones de revisi n por parte de la empresa OPTIMUS S A correr n a cargo del cliente 9 Los productos sin derechos de garant a s lo se reparar n contra pago de los gastos por el cliente En caso de ausencia de derechos de garantia OPTIMUS S A informar al cliente al respecto Si en un plazo de 6 semanas a partir de esta comunicaci n no recibimos ninguna orden de reparaci n escrita confirmando la aceptaci n de los gastos OPTIMUS S A devolver el aparato en cuesti n al cliente En este caso los gastos de transporte y embalaje se facturar n por separado y se cobrar n contra reembolso En caso de expedici n de una orden de reparaci n confirmando la asunci n de los gastos los gastos de transporte y de embalaje se facturar n adicionalmente igualmente por separado 10 En caso de necesidad de traslado al Centro de Servicio Autorizado el transporte ser realizado por el responsable de la garant a y ser n a su cargo los gastos de flete y seguro 11 En caso de falla OPTIMUS S A asegura al comprador la reparaci n y o reposici n de partes para su correcto funcionamiento en un plazo no mayor a 30 d as No obstante se deja aclarado que el plazo usual no supera los 3O d as 12 Todas las piezas o productos sustituidos al amparo de los servicios en garant a pasar n a ser propiedad de OPTIMUS S A 3 TRANSFERENCIA DE
22. ret microphone with 25 cm flexible support 4 tones Gong GONG TALK push button TALK push button Electronically configurable push buttons either lockable or unlockable Priority control GONG TALK bicolour led indicator Audio output through RJ45 connector 9 to 24 Vdc power supply either from the contact n 3 of the RJ45 connector or from an external power supply source It also enables 24V phantom power through RJ45 connector between terminals 1 and 2 Gong volume Microphone volume Configurable output level O dBm 60 dBm Electronically balanced output OP VIMUS 3 OP VIMUS Fig 1 3 CONTROLES 1 LED indicador ver Fig 1 n 1 Mientras se esta generando el gong el Led se mantiene iluminado en rojo Cuando ha finalizado cambia a color verde indicando que se puede empezar a hablar 2 TECLA TALK ver Fig 1 n 2 Permite dar un aviso sin que se genere la se al gong 3 TECLA GONG TALK ver Fig 1 n 3 Al pulsar esta tecla el pupitre genera el gong y se puede empezar a hablar 4 CONTROL DE VOLUMEN DE GONG ver Fig 2 n 4 Se puede atenuar el volumen del gong mediante un potenci metro de ajuste accesible desde la parte inferior de la base 5 CONTROL DE VOLUMEN DE MICRO ver Fig 2 n 5 Se puede atenuar el volumen del micro mediante un potenci metro de ajuste accesible desde la parte inferior de la base MD 20 v1 2 MD 20 PUPITRE MICROFONICO MICROPHONE DES
23. ured ex factory 4400 milliseconds see section 4 2 e Lockable push button configured ex factory unlockable see sec 4 3 e Shield ground link configured ex factory linked see sec 4 4 4 1 OUTPUT LEVEL This model allow to configure the output level at O dBm or at 60 dBm The configuration ex factory is of 0 dBm To change it to 60 dBm you have to configure the jumpers JP1 JP3 JP5 and JP6 see Fig 4 4 2 COMPRESSOR The J4 jumper see Fig 4 allows to configure the compressor release time 4 3 TALK MODE The J3 jumper allows to configure lockable push buttons you must keep pressed the GONG TALK key until the message is ended or unlockable push buttons you must press the GONG TALK key and once the message is ended press it again Unlockable push buttons set the J3 jumper to the PUSH TO TALK position see Fig 4 Lockable push buttons set the J3 jumper to the START AND STOP position see Fig 4 4 4 SHIELD GND LINK The internal J7 jumper allows to separate the RJ45 cable shield from the microphone internal mass By default the devide shield and ground are joined jumper in position To separate them remove the J7 jumper see Fig 4 OP VIMUS 5 e MD 20 Teen oF JP5 JP1 JP3 JP6 AUDIO OUTPUT LEVEL Fig 4 Factory setup PUSH 4400 ms LINKED TO TALK T START 2200 ms UNLINKED AND STOP 14 550 ms J4 J4 COMPRESSOR RELEASE TIME milliseconds