Home
        RS-0001 V1.2 User Guide - Guía del usuario
         Contents
1.    CHANNELL  Rain Barrel    User Guide   Gu  a del usuario    RS 0001 v1 2       Congratulations on purchasing the finest rain barrel made     Felicitaciones por adquirir el mejor tanque de aguas pluviales que se haya realizado        Warnings Regarding Potential Hazards   Precauciones de Seguridad    PLEASE REFER TO HAZARD WARNINGS BOOKLET FOR MORE INFORMATION  POR FAVOR CONSULTE EL CUADERNILLO DE ADVERTENCIAS PARA M  S INFORMACI  N     Drowning Hazard Contamination Hazard    Riesgo de ahogamiento Riesgo de contaminaci  n    Electrocution Hazard Installation Hazard  Riesgo de electrocuci  n Riesgo de instalaci  n    Tilting Tipping Hazard Infestation Hazard    Riesgo de inclinaci  n  Riesgo de infestaci  n  vuelco    Wear Safety Glasses Wear Safety Gloves  Use gafas de seguridad Use guantes de seguridad       Page 1    2     The Channell Rain Barrel is a state of the art sealed rainwater collection  system  With our patented Connection Kit Diverter  the Channell Rain  Barrel is easy to install  clean  and winterize  Properly installed  it will  provide years of trouble free use     Please read all instructions and warnings before installation  and retain  6   this brochure for future reference     P  Channell Rain Barrel es un innovador sistema sellado de recolecci  n  lt  H   de aguas pluviales  Con nuestro derivador patentado Connection Kit  o     el sistema Channell Rain Barrel es f  cil de instalar  limpiar y aislar Ga W  gt  gt        AS  t  rmicamente  Si se instala co
2.  8    
3.  Existen varias maneras de acceder y distribuir el agua en el tanque  Contamination Hazard Las aguas pluviales no son    convenientes para el consumo    Utilice tanta agua almacenada como sea posible para hacerle lugar a las nuevas aguas pluviales Riesgo de contaminaci  n o ca       1  A Watering Can or Bucket can be filled by using the spigot     1  Un bid  n o balde con agua puede llenarse con el grifo    Tp     2  A Garden Hose can be connected to the spigot or bottom drain for watering remote areas   Note  To achieve gravity fed water flow  the barrel must be higher than the area to be watered     Elevating the rain barrel will improve water pressure   2  Para   reas remotas de regado  puede conectarse una manguera para   jard  n al grifo o parte inferior de drenaje  Nota  Para  alcanzar un flujo de agua alimentada por la gravedad  el tanque debe estar en una posici  n m  s elevada que el   rea a regar     Elevar el tanque de aguas pluviales mejorar   la presi  n de agua    3  A Soaker Hose can be connected to the spigot or bottom drain  If connecting to bottom drain  an inline garden hose valve  should be fitted in place of the drain cap  This will allow the water to be turned on off as needed     3  Una manguera de ye a puede conectarse al grito o parte inferior de drenaje  Si la conecta a la parte inferior de drenaje  la  v  lvula de entrada de la manguera para jard  n debe estar colocada en el lugar de la tapa de drenaje  Esto permitir   encender   apagar la corriente
4.  de agua seg  n sea necesario       po   4  A Garden Hose Timer can be fitted between bottom drain and soaker hose to automatically dispense water at regular intervals   Be sure the timer is designed for low pressure applications     4  Un temporizador de la manguera para jard  n puede colocarse entre la parte inferior de drenaje y la manguera de irrigaci  n  para expender agua en forma autom  tica durante intervalos regulares  Est   seguro que el medidor de tiempo este dise  ado para  aplicaciones de baja presi  n     Always be sure to tighten spigot after use   Even a slow drip will empty the barrel over time     Siempre aseg  rese de cerrar bien el grifo luego de utilizarlo   A  n un goteo lento vaciar   el tanque con el tiempo         13 Linking Barrels  Optional  Uni  n de tanques  Opcional     RainStation barrels can be linked together to increase water Los tanques RainStation pueden ser conectados entre ellos para incrementar la capaci    storage capacity  dad de agua    1      Drilla 1 5    diameter hole on the flat area beside the fill hole  Use the dimple 1      Taladre un agujero de 1 5    de di  metro en la parte plana junto al agujero de  molded on the flat area to center the drill bit  Insert the second water Inlet into the llenado  Use el agujero marcado en la parte plana para centrar la broca   hole until the inlet rim sits flat against the barrel  2  Inserte la segunda entrada de agua en el agujero hasta que el anillo de la   2  Insert the fill hose from the 
5.  s flange sits flat against  the downspout  Check that the arrow on the outside of the Diverter is pointing  straight up     Use two of the self tapping screws to attach the Diverter to the  downspout     Diverter collection funnel must face up to work     For a 3x4    downspout refer to fig  A   For a 2x3    downspout refer to fig  B     A    WARNING    Perforaci  n del orificio del derivador Connection Kit    Perfore un orificio en el bajante con una sierra cil  ndrica de 2 1 8     El centro  de la sierra cil  ndrica debe estar alineado con el punto central marcado sobre  el bajante  Luego de realizar la perforaci  n  retire cuidadosamente la sierra  cil  ndrica para evitar que la pieza cortada se caiga dentro del bajante     a  Cuando realice el corte  no fuerce el taladro  Realice el corte en forma lenta y  constante     b  Siempre utilice gafas de seguridad y guantes de seguridad cuando realice  cortes y perforaciones     El borde de corte del bajante puede ser filoso  Use guantes prot tores de seguri     dad     For 3x4    downspout  drill hole on narrow 3    side  Para un drenaje del techo de 3x4     taladre el agujero en el  lado m  s estrecho                          Instalaci  n del derivador Connection Kit    Conecte la manguera llenadora al derivador FlexiFit antes de instalarlo al bajante   Presione la manguera dentro del derivador hasta que la secci  n corrugada est    alineada con el extremo del derivador     Inserte el derivador dentro del orificio del bajante
6.  y aseg  rese de que el embudo  de recolecci  n est   hacia arriba  Emp  jelo hasta que la brida del derivador se  apoye bien contra el bajante  Verifique que la flecha ubicada en la parte externa  del derivador est   recta hacia arriba     3  Utilice 2 de los tornillos autorroscantes para ajustar el derivador al bajante     El embudo de recolecci  n del derivador debe estar hacia ar  riba para que funcione     Para un drenaje del techo de 3x4    consultar a la fig  A   Para un drenaje del techo de 2x3    consultar a la fig  B     Installation Hazard  Riesgo de instalaci  n  3 SO    WARNING       ADVERTENCIA    A    Electrocution Hazard  Riesgo de electrocuci  n    E e    WARNING       Wear Safety Glasses  Use gafas de seguridad    WARNING    E gt     Wear Safety Gloves  Use guantes de seguridad       D    N             Soapy water or hand lotion on the hose cuff and rubber seal reduces  iction and makes insertion easier     CONSEJO    Agua enjabonada o crema de mano en el pu  o de la manguera y en  el sello de hule reduce fricci  n y permite que la entrada sea m  s f  cil        Page 5    Connecting the Barrel    1  Connect the other end of the fill hose to the water inlet on barrel     Press hose end firmly into the water inlet until it    bottoms out        The hose can be cut using scissors or a work knife  if a shorter length is    required     a  The hose can only be cut in one foot increments  at the center of a flat    section     A sagging hose will collect water  wh
7. aring the Site    The Channell Rain Barrel should be located close to a downspout  near the  anticipated area of use on a solid and level service     a  Ifthe spigot is used to distribute water  the area directly in front of the spigot  should be easily accessible     b  Ifa garden hose or soaker hose is used to distribute water  the barrel  and entire length of the hose path must be elevated above the area to be  watered     Place the barrel in the intended location and check to see that the fill hose can  reach from the downspout to the water inlet on the barrel     To make sure the surface beneath the barrel is level  set a beam level on the  barrel rim to check     If using a garden hose  the barrel should be elevated for maximum  water pressure          Instalaci  n del tanque    ll       Instalaci  n del drenaje inferior   a  Inserte una peque  a junta dentro del orificio de drenaje ubicado cerca de la  parte inferior del tanque     b  Enroque la tapa de drenaje en la salida de drenaje y aseg  rese de que la tapa  est   colocada en el lateral roscado m  s amplio     c  Enrosque el ensamble en la junta del orificio de drenaje  hasta que el collar  n  hexagonal quede ajustado contra la junta     Para evitar que el sello se da  e  no lo ajuste demasiado     Instalaci  n del grifo   a  Inserte la segunda junta peque  a dentro el orificio del grifo ubicado en el  punto medio del tanque     b  Enrosque el grifo dentro de la junta hasta que quede ajustado y colocado con  la sa
8. arrel utiliza un derivador alimentado por gravedad Connec   tion Kit para desviar el agua hacia el tubo bajante cuando el tanque se haya llenado  de aguas pluviales     El derivador est   insertado dentro del orificio que se corta en el bajante     1  El orificio debe estar perforado a la altura correcta para que el deriva  dor funcione adecuadamente     2  Siel orificio est   cortado a una altura demasiado baja  el taque no se llenar       3  Siel orificio est   cortado a una altura demasiado elevada  el agua se  desbordar   del tanque     No corte el bajante hasta leer instrucciones pasos 7 y 8    IF the hole is cut too low  the  barrel will not fill     Si el orificio est   cortado a  una altura demasiado baja  el  taque no se llenar       If the hole is cut too high   water will overflow from the  barrel rim     Si el orificio est   cortado  a una altura demasiado  elevada  el agua se  desbordar   del tanque     Marca del orificio del derivador Connection Kit    1  Marque una l  nea de referencia aunque sea a la altura del tanque sobre la  parte inferior del bajante con un l  piz y un nivelador  ubicado sobre el borde  del tanque como gu  a     2  Mida 2 pulgadas  50mm  por debajo de la l  nea de referencia y realice otra  l  nea marque otra l  nea en el bajante  Luego  realice una marca sobre la l  nea  inferior para mostrar el centro del bajante     Aseg  rese de tomar en cuenta cualquier base elevada     For 3x4    downspout  mark hole on narrow 3    side    Para un dr
9. e debajo del tanque est   nivelada   coloque un nivelador sobre el borde del tanque para verificar     Si utiliza una manguera para jard  n  el tanque debe estar elevado para una  presi  n m  xima de agua       Page 3     6  About the Connection Kit Diverter    The Channell Rain Barrel uses a gravity fed Connection Kit Diverter to redirect water  to the downspout when the barrel is full of rainwater     The diverter is inserted into a hole that is cut into the downspout     1      The hole must be drilled at the correct height for the diverter to  work properly     IF the hole is cut too low  the barrel will not fill     3  Ifthe hole is cut too high  water will overflow from the barrel rim     Do not cut the downspout until reading instruction steps 7 and 8     Not for use with round downspouts     Damage to home or  property may occur if  improperly installed     ADVERTENCIA    Se pueden producir da  os en   el hogar o en la propiedad si   la instalaci  n se realiza incor   rectamente            7  Marking the Connection Kit Diverter Hole    1  Mark a reference line even with the height of the barrel on the  downspout using a pencil and a beam level  placed on the barrel  rim as a guide     2  Measure 2 inches  50mm  below the reference line and make another line on  the downspout  Next make a mark on the lower line to show the center of  the downspout     Be sure to take any elevated base into account        Acerca del derivador Connection Kit    El sistema Channell Rain B
10. ection Kit 6  Work knife   Cuchilla de trabajo   8  Winterization hole cover   Tapa del orificio de aislamiento t  rmico 7  Measuring tape or ruler   Cinta m  trica o regla   9  Hole Saw  2 1 8       Sierra cil  ndrica  2 1 8     8  Drill   Taladro   The cutting edge of the hole saw is sharp and presents a hazard  lt   must be used only as directed in this User Guide  9  Solid surface base  optional    Base s  lida para superficie  10  Screws  3    Tornillos  3    11  User guide   Gu  a del usuario   12  Hazard Warnings Bookleiibrete de las advertencias del peligro                            gt     Do Not Discard Lid                                                                         e        Assembling the Barrel    Install bottom drain     a  Insert small gasket into drain hole near bottom of barrel   b  Thread drain cap onto the drain post  making sure the cap is on the larger     threaded side     c  Thread the assembly into the drain hole gasket until the hex collar is tight  against the gasket     To prevent damage to the seal  do not over tighten     Install the spigot     a  Insert second small gasket into spigot hole at mid height on  the barrel     b  Thread spigot into the gasket until the spigot is tightened and positioned  with the water outlet pointing down     Install the water inlet     a  Insert the inlet into the fill hole below the rim on the backside of the barrel     b  Push the inlet in until it sits Flat against the barrel      5  Selecting and Prep
11. enaje del techo de 3x4     marque el agujero  en el lado m  s estrecho     The barrel must be  installed on a solid  and level base     ADVERTENCIA    El tanque debe estar  instalado sobre una base  nivelada y s  lida         9  Installing the Connection Kit Diverter    Drilling the Connection Kit Diverter hole    Drill a hole in the downspout with a 2 1 8    hole saw  The center of the hole  saw should align with center point marked on downspout  After drilling   carefully remove the hole saw to prevent the cut out piece from falling into the  downspout    a  When cutting  do not force the drill  Cut slow and steady   b  Always use safety glasses and safety gloves when cutting  or drilling     The cut edge of the downspout can be sharp  Wear protective  safety gloves     The cutting edge of the hole saw is sharp and presents a hazard  It  must be used only as directed in this User Guide     WARNING    A    Installation Hazard  Riesgo de instalaci  n    WARNING    A    Electrocution Hazard  Riesgo de electrocuci  n       WARNING    Crp    Wear Safety Glasses  Use gafas de seguridad    WARNING    E gt     Wear Sofety Gloves  Use guantes de seguridad    Connect filler hose to the FlexiFit Diverter before installing it into the down  l     spout  Press the hose into the Diverter until the corrugated section is flush with  the Diverter end     Insert diverter into downspout hole by squeezing the sides  making sure the 2     collection funnel faces up  Push in until the Diverter  
12. ght  If it is below the level of the    barrel fill inlet  the barrel will not fill efficiently     Drain barrel and lower the ground beneath it  so that the barrel sits at the cor     rect height  according to instructions     6  Check spigot and bottom drain to make sure water is not leaking  Even a  slow leak will drain the barrel over time     The barrel overflows and water leaks out from the lid     1  The barrel is too low     To correct  drain barrel and construct a solid base to raise the barrel to the  correct height  according to the instructions  See Panel 6      The fill hose can be replaced by a 1 1 4    bilge hose available at most home  centers     WARNING    Electrocution Hazard  Riesgo de electrocuci  n    Tilting Tipping Hazard    Riesgo de inlinaci  n vuelco    Aislamiento t  rmico del tanque    El tanque puede da  arse si es utilizado en temperaturas bajo cero     Para aislarlo t  rmicamente     1  Desconecte el derivador Connection Kit al retirar los 2 tornillos  apriete los latera   les y tire el derivador hacia afuera     2  Drene el tanque completamente y aseg  rese de que el agua sea drenada de los  edificios  cimientos  pasarelas  etc     3  Conecte el orificio en el derivador con la tapa de aislamiento t  rmico del orificio     Antes de almacenarlo  limpie los desechos o sedimentos del fondo del tanque  del de   rivador y de la manguera de llenado  Vuelva a ajustar la tapa al conector de drenaje   una vez que el tanque est   vac  o     El agua conge
13. ich reduces filling efficiency     Conexi  n del tanque    1  Conecte el otro extremo de la manguera de llenado a la entrada de agua del  tanque     2  Presione el extremo de la manguera dentro de la entrada de agua hasta que  toque fondo     3  La maguera puede cortarse con tijeras o una cuchilla de trabajo  si se requi   ere una longitud m  s corta     a  La manguera   nicamente puede cortarse en incrementos de un pie  en el  centro de la secci  n plana     Una manguera suelta que recolecte agua reducir   la eficiencia    de llenado     WARNING       A    Electrocution Hazard  Riesgo de electrocuci  n    mg  WARNING    A    Installation Hazard  Riesgo de instalaci  n  Be AA    WARNING       Wear Sofety Gloves  Use guantes de seguridad      friction and makes insertion easier     CONSEJO    Agua enjabonada o crema de mano en el pu  o de la manguera y en  el sello de hule reduce fricci  n y permite que la entrada sea m  s f  cil        41  Covering and Locking the Lid    C  mo tapar y bloquear la tapa    1  Place lid on the barrel  making sure the arrow on barrel rim is pointing to the 1  Coloque la tapa sobre el tanque y aseg  rese de que la flecha ubicada en el borde    Unlock icon on lid   2  To lock lid  turn lid until arrow points to the Lock icon     3  To unlock lid  turn lid until arrow points to the Unlock icon     A screw has been provided to prevent barrel from being unlocked  To use  turn  lid to the locked position and center the screw on the dimple below the Loc
14. k    icon  Carefully drive the screw through the rim of barrel and lid     The screw must be removed before twisting the lid to the  Unlock position        del tanque apunte hacia el icono de desbloqueo de la tapa     2  Para bloquear la tapa  g  rela hasta que la flecha apunte hacia el icono de blo   queo     3  Para desbloquear la tapa  g  rela hasta que la flecha apunte hacia el icono de  desbloqueo     4  Se ha proporcionado un tornillo para evitar que el tanque sea desbloqueado   Para utilizarlo  gire la tapa hacia la posici  n de bloqueo y centre el tornillo en la  cavidad ubicada debajo del icono de bloqueo  Dirija cuidadosamente el tornillo a  trav  s del borde del tanque y de la tapa     El tornillo debe ser retirado antes de girar la tapa hacia la  posici  n de desbloqueo     WARNING    A    Drowning Hazard  Riesgo de ahogamiento    WARNING    A    Contamination Hazard a    Riesgo de contaminaci  n SO A  A   E    A    Installation Hazard  Riesgo de instalaci  n  AA       WARNING    ADVERTENCIA    Lid must be locked at all times  to prevent injury to children   La tapa debe de estar cerrada  en todo momento para prevenir  posibles da  os a ni  os        Page 6     12 Using the Channell Rain Barrel   C  mo usar Channell Rain Barrel MALE WARNING  ADVERTENCIA ADVERTENCIA    There are several ways to access and distribute the water in the barrel  di is not     H suitable for human or  Use as much stored water as often as possible to make room for new rainwater  animal S 
15. lada puede da  ar el tanque de aguas pluviales y anular la garant  a            Resoluci  n de problemas    El tanque no se llena con agua luego de llover     1  Verifique si el grifo de drenaje est   bloqueado en la conexi  n del bajante     2  Retire el derivador Connection Kit y verifique que   l y la manguera no est  n  bloqueados por hojas o sedimentos     3  Aseg  rese de que el derivador est   instalado con el embudo de recolecci  n hacia  arriba     4  Aseg  rese de que la manguera llenadora no est   elevada sobre el derivador     5  Aseg  rese de que el derivador est   instalado a la altura correcta  Si est   por  debajo del nivel de la entrada de llenado del tanque    ste no se llenar   en forma  eficiente     Drene el tanque y descienda el suelo que se encuentra debajo para que el tanque  se apoye a la altura correcta  seg  n las instrucciones     6  Verifique el grifo y la parte inferior de drenaje para asegurarse de que est   perdi   endo agua  A  n una p  rdida lenta drenar   el tanque con el tiempo     El tanque se desborda y pierde agua por la tapa   1  El tanque est   demasiado bajo     Para corregirlo  Drene el tanque y construya una base s  lida para elevarlo a la  altura correcta  seg  n las instrucciones  consulte Paso 6      La manguera de llenado puede reemplazarse por una manguera de desagote de 1  1 4    disponible en la mayor  a de los centros de art  culos para el hogar     WARNING    Tilting Tipping Hazard    Riesgo de inlinaci  n vuelco       Page
16. lida de agua hacia abajo     Instalaci  n de la entrada de agua     a  Inserte la entrada de agua dentro del orificio de llenado ubicado debajo del  borde de la parte trasera del tanque     b  Empuje la entrada de agua hasta que se apoye bien contra el tanque     TIP    Pinch the threaded rubber seal into a     C    shape before inserting into the hole  in the barrel     TIP    Soapy water or hand lotion on the hose  cuff and rubber seal reduces friction and  makes insertion easier     CONSEJO    Agua enjabonada o crema de mano en el  pu  o de la manguera y en el sello de hule  reduce fricci  n y permite que la entrada  sea m  s f  cil     CONSEJO    Apriete el sello roscado de hule en la forma  de    C    antes de insertarlo en el agujero    de barril        Selecci  n y preparaci  n del lugar    El sistema Channell Rain Barrel debe estar ubicado cerca del bajante de  aguas pluviales  cerca del   rea anticipada de uso en una superficie solida  y nivelada     a  Si utiliza el grifo para distribuir agua  el   rea directamente del frente del grifo  debe ser f  cilmente accesible     b  Si utiliza una manguera para jard  n o una manguera de irrigaci  n para distri   buir el agua  el tanque y la longitud total del recorrido de la manguera deben  estar elevados por encima del   rea a regar     Coloque el tanque en la ubicaci  n prevista y rev  sela para ver que la manguera  de llenado llegue desde el bajante hasta la entrada de agua del tanque     Para asegurar de que la superfici
17. rrectamente  brindar   a  os de uso sin  lt     Os    problemas     Lea todas las instrucciones y advertencias antes de realizar la  instalaci  n y conserve este folleto para futuras referencias     1  Barrel   Tanque  Lid   Tapa  Spigot   Grifo    A e    Drain or hose attachment   Accesorio de ajuste para drenaje o  manguera    a      Fill hose   Manguera de llenado  6  Connection Kit Diverter   Derivador Connection Kit    7  Winterization Hole Cover   Tapa del orificio de  aislamiento t  rmico    The Channell Rain Barrel barrel and lid are 100  recyclable   Made from approximately 30  recycled content  A 2       El tanque Channell Rain Barrel y la tapa son 100  reciclables y est  n    e   l   Some areas prohibit the use of rain barrels  Please check local regulations before installing   realizados con 30  aproximadamente de material reciclado        Algunas zonas proh  ben el uso de tanques para aguas pluviales  Verifique las reglamentaciones locales  antes de realizar la instalaci  n      3  Contents   Contenidos Tools Needed   Herramientas necesarias    1  Barrel   Tanque G5 1  Safety glasses   Gafas de seguridad   2  Lid   Tapa GS 2  Safety gloves   Guantes de seguridad   a i a ES 3  Phillips screwdriver   Destornillador de cruz Phillips  4  Water inlet  2    Entrada de agua  2  A   5  Spigot and gasket   Grifo y junta 4  Perici lapiz   6  Drain plug  cap  and gasket   Tap  n de drenaje  tapa y junta 5  Beam level   Nivelador   7  Connection Kit Diverter   Derivador Conn
18. second barrel into the inlet on first entrada de agua se ajuste contra el tanque  Inserte la manguera de llenado del  barrel to link  segundo tanque dentro de la entrada de agua del primer tanque para unir     WARNING    A    Installation Hazard  Riesgo de instalaci  n    WARNING    Wear Sofety Glasses  Use gafas de seguridad    WARNING    ED    Wear Sofety Gloves    Use guantes de seguridad       Winterizing the Barrel    The barrel can be damaged if used in freezing temperatures     To Winterize     1  Disconnect Connection Kit Diverter by removing the 2 screws  squeezing the  sides and pulling the diverter out of the downspout     2  Completely drain barrel making sure the water is being drained away from  buildings  foundations  walkways  etc     3  Plug the hole in the downspout with the winterization hole cover     Before storing  clean debris or sediment in the bottom of the barrel  diverter  and  fill hose  Reattach the cap to the drain plug once the barrel is empty     Freezing water can damage rain barrel and void warranty        ADVERTENCIA        The barrel does not fill with water after rainfall     1     Check the drain gutter for blockage at the downspout connection     2  Remove the Connection Kit Diverter and check that it and the hose are not  blocked by leaves or debris    3  Make sure Diverter is installed with collection funnel facing up    4  Make sure the filler hose is not raised above the Diverter    5  Make sure Diverter is installed at the right hei
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung SV-DVD3E User's Manual  Oregon TR118 User's Manual  trackspot ® Bolt User Manual  See it at CiteSeerX    Télécharger le manuel d`utilisation  Galaxy SII™ & Note™ Connection Kit User Manual  説明書 - 任天堂  30RQ 039-160 Pompe à chaleur réversible air-eau  La Loire à Vélo, un parcours unique à vivre intensément.    Copyright © All rights reserved. 
   Failed to retrieve file