Home

H - KWIK-DRAW™ Gas Detector Tubes

image

Contents

1. 1 10 Anv ndningsomr de F r m tning av bensen C H halten i luft eller kemiska gaser Analysr rspumpar MSA AUER Gas Tester l och IlI H Kwik Draw pumpen Toximeter ll och annan l mpliga analysr rspumpar Se bruksanvisningar M tomr de 5 ppm 100 ppm bensen f r 10 pumptag n 10 M tprincip Oxidation av bensen med iodat svavelsyra F rgomslag vitt gt brun M tning Kontrollera att analysr rspumpen r t tt Bryt av analysr rets b da spetsar S tt in r ret t tt till pumpen Gas Tester och II H Pilen p analysr ret pekar mot pumpen Toximeter Il S tt in r ret till luftintagets sidan vitt pil Pilen p insatsr ret pekar mot pumpen Faktor se f rpackningen Tag 10 pumptag e Avl s v rdet inom 2 minuter e R ren kan bara anv ndas en gang oavsett inf rgning 40 50 sek pumptag Inflytande av temperatur fukt och tryck Analysr ret kan anv ndas inom temperaturomr det 0 40 C utan korrektion och vid abs fuktighet upp till 15 g m 85 rel fuktighet vid 20 C 30 rel fuktighet vid 40 C Korrigering f r lufttryck 1013 mbar avl st v rde ppm x aktuellt lufttryck mbar Inflytande av andra mnen a M tv rdet st rs ej av v tgas metan etan propan butaner koloxid koldioxid ven ver 50 Vol svaveldioxid kv veoxid kv vedioxid upp till 1000 ppm b M ttade kolv ten hexaner oktaner o dyl olefin kol
2. 30 d humidit relative 40 C 104 F Compensation de pression multiplier la lecture en ppm par le facteur F p 1013 mbar 760 mmHg o pression atmosph r mbar z pression atmosph r mmHg 7 Interf rences a Pas d interf rences avec hydrog ne m thane thane propane butanes monooxyde de carbone dioxyde de carbone m me en concentrations sup rieures 50 Vol dioxyde de soufre oxyde nitrique dioxyde d azote jusqu 1000 ppm b Les hydrocarbures satur s par ex les hexanes les octanes les hydrocarbures ol finiques par ex thyl ne hydrog ne sulfur le disulfure de carbone sont d tect s avec une r action color e p le brune ou ros indication du benz ne se d tache distinctement du fond color p le c Les hydrocarbures aromatiques plus lourds par ex le tolu ne les xyl nes sont d tect s avec une r action colorante roug tre brun La sensibilit de l indication est plus faible que pour le benz ne 8 Pr cision Jusqu 15 pour des valeurs sup rieures 20 ppm Jusqu 25 pour des valeurs comprises entre 5 ppm et 20 ppm Pourcentage exprim par rapport la valeur lue 9 Stockage et transport Jusqu 25 C 77 F l abri de la lumi re Date de p remption voir au dos de la bo te 10 Mesures de s curit Pour le contenu des tubes les indications de danger suivantes s appliquent R 21 22 34 Conseils de prudence S 2
3. C y 40 C 32 F y 104 F y hasta 15 g m vapor d agua 85 rh a 20 C 68 F 30 rh a 40 C 104 F Para compensar la influencia de la presi n atmosf rica multiplicar la lectura en ppm por el factor de correcci n F e 1013 mbar 760 mmHg S pres atmosf observada mbar 8 pres atmosf observada mmHg Interferencias de Otras Sustancias a No interferencia debida a hidr geno metano etano propano butanos mon xido de carbono di xido de carbono incluso en concentraciones por encima de 50 Vol di xido de azufre mon xido de nitr geno di xido de nitr geno hasta el minimo de 1000 ppm b Hidrocarburos saturados p e hexanos octanos hidrocarburos olef nicos p e etileno cido sulfh drico sulfuro de carbono se manifiestan con una decoloraci n de la mancha marr n p lida o rosada La indicaci n del benceno es facilmente legible sobre este fondo c Hidrocarburos arom ticos superiores p e tolueno xilenos producen indicaci n rojizo marr n La sensibilidad de indicaci n es m s baja comparando la indicaci n de benceno Exactitud Hasta 15 por encima de 20 ppm Hasta 25 entre 5 ppm y 20 ppm referido a la desviaci n estandard Almacenaje y Transporte Hasta 25 C 77 F y protegidos de la luz Fecha de caducidad Ver la parte posterior de la caja Precauciones para el Manejo y Vertido Para el contenido del tubo se aplican los siguientes indicaci
4. 24 25 26 28 eau Emploi limit aux personnes autoris es Pour l limination observer les consignes applicables dans chaque pays Fabriqu en Allemagne par MSA AUER GmbH Germany www msa tubes com Detector Tube kd AUER C H 5 Part No 804411 Instructions for Use 1 10 Application Detection of benzene C H in air or in technical gases Detector Tube Sampling Pump MSA AUER Gas Tester Il H Kwik Draw Pump Gas Tester L Toximeter ll or other suitable detector tube sampling pumps Observe respective instructions for use Measuring Range 5 ppm 100 ppm benzene at n 10 10 pump strokes Chemical Reaction and Color Change Oxidation of benzene by an iodate sulfuric acid reagent Color change white gt brown Sampling Procedure e Check detector tube pump for leakage Break off both tube tips Insert detector tube tightly into pump Gas Tester Kwik Draw pump ThumpPump Sampler Arrow on tube must point toward the pump Toximeter II Insert tube into inlet side white arrow Arrow on tube must point toward pump Factor see package Perform 10 pump strokes Read concentration at end of color zone within 2 minutes after sampling Used detector tubes without any color change cannot be used repeatedly Duration of one pump stroke 40 50 seconds Ambient Conditions During Sampling Detector tubes can be used without compensation of the reading between 0 C and 40 C 32 F and 104 F and in the hum
5. Pr fr hrchen kd AUER LH Bestellnummer D5085816 Gebrauchsanleitung 1 Anwendung Messung von Benzol C H in Luft oder technischen Gasen 2 Pr fr hrchenpumpe MSA AUER Gas Tester ll H Kwik Draw Pumpe Gas Tester l Toximeter Il oder andere geeignete Pumpen Handhabung entsprechend jeweiliger Gebrauchsanleitung 3 Me bereich 5 100 ppm Benzol bei 10 Pumpenh ben n 10 4 Anzeigeprinzip Farbumschlag Oxidation von Benzol durch lodat Schwefels ure Farbumschlag wei gt braun 5 Durchf hrung der Messung Pr fr hrchenpumpe auf Dichtheit pr fen Pr fr hrchenspitzen abbrechen Pr fr hrchen dicht in Aufnahme der Pumpe einsetzen Gas Tester MSA Kwik Draw Pumpe Pfeil auf Pr fr hrchen mu zur Pumpe zeigen Toximeter Il Saugseitig einsetzen weisser Pfeil Pfeil auf Pr fr hrchen mu zur Pumpe zeigen Faktor siehe Pr fr hrchenpackung 10 Pumpenh be durchf hren Anzeige am Ende der Farbzone innerhalb 2 Minuten nach Beendigung der Messung ablesen Gebrauchte Pr fr hrchen ohne Anzeige k nnen nicht mehr verwendet werden Dauer eines Pumpenhubes 40 SO Sekunden 6 Umgebungsbedingungen bei der Messung Pr fr hrchen k nnen ohne Korrektur der Anzeige verwendet werden von 0 C bis 40 C und im Feuch tebereich bis 15 g m 85 RF bei 20 C 30 RF bei 40 C Druckkorrektur Anzeigewert ppm mit Korrekturfaktor F multiplizieren e 1013 mbar tats chlicher Luftdruck mbar 7 Ein
6. UER GmbH Germany Tubos Detectores kd AUER LH Node pedido D5085816 Modo de empleo 1 10 Aplicaci n Medici n de la concentraci n de benceno C H en el aire o en gases t cnicos Bomba de Muestreo para Tubos Detectores MSA AUER Gas Tester Il H Kwik Draw Pump Gas Tester ThumpPump Sampler Toximeter Il o otras bombas de muestreo apropriadas V anse las correspondientes instrucciones de funcionamiento Campo de Medida 5 ppm 100 ppm benceno para n 10 10 emboladas Reacci n Qu mica y Cambio de Color Oxidation de benceno por pent xido de yodo en cido sulf rico Cambio de color blanco gt marr n Procedimiento de Muestreo Comprobar estanqueidad de la bomba Romper ambas puntas del tubo e Insertar el tubo detector firmemente en la bomba Gas Tester Kwik Draw Pump ThumbPump Sampler La flecha del tubo indicador debe indicar en direc ci n a la bomba Toximeter Il insertar el tubo indicador en la entrada de aire flecha blanco La flecha del tubo indicator debe indicar en direcci n a la bomba Factor ver la caja e Efectuar 10 emboladas e Leer la concentraci n al final de la zona coloreada dentro de los 2 minutos siguientes a la toma de muestra e Los tubos detectores usados no pueden ser reutilizados Duraci n de una embolada 40 50 segundos Condiciones Ambientales Durante el Muestreo Los tubos detectores pueden utilizarse con exactitud a temperaturas entre 0
7. flu anderer Stoffe Querempfindlichkeit a Kein St reinflu durch Wasserstoff Methan Ethan Propan Butane Kohlenmonoxid Kohlendioxid auch in Konzentrationen ber 50 Vol Schwefeldioxid Stickstoffmonoxid Stickstoffdioxid bis mind 1000 ppm b Ges ttigte Kohlenwasserstoffe z B Hexane Octane Olefin Kohlenwasserstoffe z B Ethylen Schwefelwasserstoff Schwefelkohlenstoff werden mit hellbrauner oder rosa Verf rbung angezeigt Die Benzol Anzeige hebt sich deutlich vom hell verf rbten Untergrund ab c H here aromatische Kohlenwasserstoffe z B Toluol Xylole werden mit r tlich brauner Verf rbung angezeigt Die Anzeigeempfindlichkeit ist niedriger als Benzol 8 Me unsicherheit Bis zu 15 im Bereich ab 20 ppm Bis zu 25 im Bereich 5 20 ppm ausgedr ckt als relative Standardabweichung 9 Lagerung und Transport Bei max 25 C und vor Licht gesch tzt Verfalldatum s R ckseite der Packung 10 Sicherheitsratschl ge Entsorgung F r die F llmasse gilt gem Gefahrstoffverordnung vom April 1990 Gefahrenbezeichnung R 21 22 34 Sicherheitsratschl ge S 2 24 25 26 28 Wasser Pr fr hrchen nicht in unbefugte H nde gelangen lassen Bei der Entsorgung sind die jeweiligen gesetz lichen Bestimmungen zu beachten D5085516 09 www msa tubes com Tubes Colorim triques LEA AUER GHz Num ro de commande D5085816 Instructions d utilisation 1 Applications D tection de benz ne CH dans
8. ge bestemmelser f lges Proefbuisjes kd AUER LH Bestelnummer D5085816 Gebruiksaanwijzing 1 10 Toepassing Meting van benzeen C H in lucht of in technische gassen Proefbuisjespomp MSA AUER Gas Tester ll H Kwik Draw Pomp Gas Tester l Toximeter ll of andere juiste proefbuisjespompen Bediening overeenkomstig de van toepassing zijn de gebruiksaanwijzing Meetbereik 5 ppm 100 ppm benzeen bij 10 slagen van de pomp n 10 Indicatieprincipe kleuromslag Oxidatie van benzeen door een jodaat zwavelzuur reagens Kleuromslag wit gt bruin Uitvoeren van de meting Proefbuisjespomp op lekkage controleren De uiteinden van het proefbuisje afbreken Proefbuisjes sluitend in de opname van de pomp inbrengen Gas Tester Kwik Draw Pomp De pijlen op het proefbuisje moet in de richting van de pomp wijzen Toximeter Il Proefbuisje in de aanzuigzijde van de pomp inbrengen wit pijl Factor zie verpakking 10 slagen uitvoeren e Indicatie aan het einde van de kleurzone binnen 2 minuten na het voltooien van de meting aflezen e Gebruikte proefbuisjes zonder indicatie kunnen niet nogmaals gebruikt worden Duur van een slag van de pomp 40 50 seconden Omgevingscondities tijdens de meting Proefbuisjes kunnen zonder correctie van de indicatie gebruikt worden van 0 C tot 40 C en tot 15 g m H O 85 relatieve vochtigheid bij 20 C 30 relatieve vochtigheid bij 40 C Drukcorrectie Indicatie
9. idity range up to 15 g m 85 rh at 20 C 68 F 30 rH at 40 C 104 F Pressure compensation multiply reading in ppm with compensation factor F P 1013 mbar 760 mm Hg actual atm pressure mbar actual atm pressure mm Hg Interferences and Cross Sensitivities a No interference from hydrogen methane ethane propane butanes carbon monoxide carbon dioxide sulfur dioxide nitric oxide nitrogen dioxide up to 1000 ppm b Saturated hydrocarbons e g hexanes octanes olefinic hydrocarbons e g ethylene hydrogen sulfide carbon disulfide will be indicated by a slight brown or pink discoloration The benzene indication is distinctly readable against that background c Higher aromatic hydrocarbons e g toluene xylenes will be indicated by a reddish brown discoloration The sensitivity of indication is lower than for benzene Overall Uncertainly Up to 15 in the range above 20 ppm Up to 25 in the range 5 ppm 20 ppm expressed as relative standard deviation Storage and Transport Up to 25 C 77 F and protected from light Expiration date see back of package Safety Advice Disposal For tubes contents the following indications of danger apply R 21 22 34 Safety advice S 2 24 25 28 water Tubes must be kept away from unauthorized persons For disposal of tubes as waste observe the legal regulations applicable in the individual country of use Manufactured by MSA A
10. l air ou dans des gaz techniques 2 Pompes d chantillonnage pour tubes d tecteurs MSA AUER Gas Tester IIH Kwik Draw Gas Tester I Toximeter Il ou des autres pompes d chantillon nage appropri es Respecter les instructions d utilisation correspondantes 3 chelles de mesure 5 ppm 100 ppm de benz ne n 10 10 coups de pompe 4 R action chimique et changement de couleur Oxydation de benz ne par un r actif iodate acide sulfurique Changement de couleur blanc gt brun 5 Proc dure chantillonnage V rifier le bon fonctionnement de la pompe tanch it e Briser les extr mit s du tube Ins rer le tube fermement dans la pompe Pour le Gas Tester et le Kwik Draw la fl che dessin e sur le tube colorim trique doit tre point e vers la pompe Pour le Toximeter II on place le tube colorim trique dans l entr e d air fl che blanc Facteur Voir au bo te La fl che dessin e sur le tube doit tre point e vers la pompe Donner le nombre de coups de pompe n cessaire 10 Lire la concentration la fin de la zone color e dans les 2 minutes qui suivent la prise d chantillon Les tubes ne peuvent pas tre r utilis s apr s emploi Dur e d un coup de pompe 40 50 secondes 6 Conditions d chantillonnage Les tubes peuvent tre utilis s sans compensation de lecture entre 0 C et 40 C 32 F et 104 F et jusqu 15 g m vapeur d eau 85 d humidit relative 20 C 68 F
11. na aspirazione 40 50 secondi 6 Condizioni ambientali durante il campionamento Le fialette possono essere usate in un campo di temperature compreso tra 0 C e 40 C e in presenza di umidit assoluta fino al 15 g m 85 rh a 20 C 30 rh a 40 C Per compensare l influenza della pressione atmosferica moltiplicare il volare letto ppm per il fattore F 1013 mbar 760 mm Hg F effet press atmosf mbar effet press atmosf mm Hg 7 Interferenze e sensibilit traversali a Nessuna interferenza da idrogeno metano etano propano butani ossido di carbonio anidride carbonica anche in concentrazioni oltre 50 Vol anidride solforosa ossido d azoto biossido d azoto fino a minimo 1000 ppm b Idrocarburi saturi es esani ottani idrocarburi olefinici es etilene idrogeno solforato solfuro di carbonio verrani indicati da una scolorazione leggermente marrone o rosa L indicazione di benzolo perfettamente leggibile su questa colorazione di fondo c Idrocarburi aromatici superiori es toluolo xiloli vengono indicati da una scolorazione rossiccio marrone La sensibilit dell indicazione minore che per benzolo 8 Accuratezza Fino a 15 nel campo di misura oltre 20 ppm Fino a 25 nel campo di misura 5 ppm 20 ppm espresso come relative deviazioni standard 9 Stoccaggio e trasporto Fino a 25 C e protette dalla luce Data di scadenza vedere sul retro della scatola 10 Avver
12. ones de peligro R 21 22 34 Consejos de prudencia S 2 24 25 26 28 agua Los tubos deben mantenerse fuera del alcance de personas no autorizadas Respecto al vertido deben observarse las prescripciones legales vigentes en el pa s donde de usan Fabricado por MSA AUER GMBH Alemania Fialetta kd AUER GHz n catalogo D5085816 Instruzioni per l uso 1 Applicazione Rivelazione di benzolo C H nell aria o gas tecnici 2 Metodo di campionamento Le fialette possono essere usate con i rivelatori MSA AUER Quantigas Moderna Gas Tester e IIH Toximeter ll o altre pompe rivelatrice Seguire attentamente le istruzioni per l uso 3 Campo di misura 5 ppm 100 ppm benzolo con 10 aspirazioni n 10 4 Reazione chimica e cambio colore Ossidazione di benzolo per mezzo di un reagente iodato acido solforico Cambio colore bianco gt marrone 5 Procedura di campionamento Prima di campionare controllare la tenuta del rivelatore Rompere le due estremit sigillate della fialetta Inserire la fialetta fermamente nel bocchetto della pompa Per Quantigas Moderna e Gas Tester freccia direzione flusso verso la pompa Per Toximeter Il inserimento lato entrata freccia bianca Freccia direzione flusso verso la pompa Fattore vedere scatola Effettuare 10 aspirazioni Leggere la concentrazione alla fine della zona colorata entro 2 minuti dopo il campionamento Lefialette usate non possono essere riutlizzate Durata di u
13. temperaturer mellem 0 C og 40 C og ved absolut fugtighed indtil 15 g m 85 rel fugtighed ved 20 C 30 rel fugtighed ved 40 C Trykkorrektion Visningsv rdi ppm multipliceres med faktoren F 1013 mbar aktuelt lufttryk mbar 7 Indflydelse fra andre stoffer krydsf lsomhed interferens a Ingen p virkning pga tilstedev rende hydrogen brint methan ethan propan butaner carbonmonoxid kulilte carbondioxid kuldioxid ogs i koncentrationer over 50 Vol svovldioxid nitrogenmonoxid kv lstofmonoxid nitrogendioxid kv lstofdioxid indtil mindst 1000 ppm b M ttede kulbrinter f eks hexaner octaner olefiner f eks ethen hydrogensulfid svovlbrinte carbondisulfid vises med lysebrun rosa farvninger Benzen visningen kan tydeligt afl ses mod denne baggrund c H jere aromatiske kulbrinter f eks toluen xylener vises med r dlig brun farvninger F lsomheden erringere end for benzen 8 M leusikkerhed Indtil 15 i m leomr det over 20 ppm Indtil 25 i m leomr det 5 ppm 20 ppm udtrykt som spredning 9 Lagring og transport Temperatur under 25 C og beskyttet mod lys Udl bsdato se bagside af pakning 10 Sikkerhedsanvisninger Bortskaffelse For fyldemassen g lder Risikos tninger R 21 22 34 Sikkerhedss tninger S 2 24 25 26 28 vand velse pr ver r m ikke komme i h nderne p uvedkommende personer b rn Ved bortskaffelsen skal de g ldende lovm ssi
14. tenze di sicurezza Indicazioni di rischio per il contenuto della fialetta addestramento R 21 22 34 Consigli di prudenza S 2 24 25 26 28 acqua Tenere lontano dalla portata di persone non autorizzate Per lo smaltimento delle fialette osservare le leggi nazionali vigenti Pr ver r Cd AUER GHz Bestillingsnr D5085816 Brugsanvisning 1 Anvendelse M ling af benzen C H i luft eller tekniske gasser 2 Pr ver rspumpe MSA AUER Gas Tester Il H Kwik Draw Pumpe Gas Tester Toximeter Il eller andre velegnet pr ver rs pumpen Se tilh rende brugsanvisning 3 M leomr de 5 ppm 100 ppm benzen ved 10 pumpeslag n 10 4 Kemisk reaktion Farveumslag Oxidation af benzen med en iodat svovlsyre reagens Farveomslag hvid gt brun 5 Udf relse af testen Pr ver rspumpen kontrolleres for t thed Pr ver rets 2 spidser kn kkes af Pr ver rets inds ttes t t i pumpens studs Gas Tester Kwik Draw Pumpe Pilen p pr ver ret skal vise ind mod pumpen Toximeter Il pr ver ret inds ttes i insugnings side hvid pil Pilen p pr ver ret skal vise ind mod pumpen Faktoren se pakning 10 pumpeslag udf res Visning afl ses ved gr nsen af farvezonen inden for 2 minutter efter m lingen er fuldendt Brugte pr ver r uden visning kan ikke bruges igen Varighed af et pumpeslag 40 50 sekunder 6 Betingelser for de ydre omgivelser ved m ling Pr ver r kan uden korrektion af visningen anvendes i
15. v ten etylen o dyl svavelv te koldisulfid ger utsiag Ijusbrun rosa Bensen halten r tydeligt avl ster mot denna backgrund c H gre aromatiska kolv ten toluen xylener o dyl ger utslag r daktig brun Kensligheten r l ger som f r bensen M tnoggrannhet Upp till 15 ver 20 ppm Upp till 25 inom koncentrationsomr det 5 ppm 20 ppm uttryckt som rel standard avvikelser Lagring och transport Vid lagring ljusskyddat vid max 25 C g ller p f rpackningen angivet sista anv ndningsdatum S kerhetsregler R 21 22 34 S 2 24 25 26 28 vatten Analysr ren inneh ller fr tande kemikalier Undvik hudkontakt med dessa lakttag f rsiktighet F rvaras o tkomligt f r obeh rige barn Anv nda utg ngna r r ska hanteras enligt g llande best mmelser
16. waarde ppm vermenigvuldigen met factor F 1013 mbar werkelijke luchtdruk mbar Invloed van andere stoffen dwarsgevoeligheid a Geen storende invloed door waterstof methaan ethaan propaan butaanen koolmonoxide kooldioxide ook in concentraties boven 50 Vol zwaveldioxide stikstofmonoxide stikstofdioxide tot ten minste 1000 ppm b Verzadigde koolwaterstoffen bijvoorbeeld hexanen octanen olefine koolwaterstoffen bijvoor beeld ethyleen zwavelwaterstof cooldisulfide worden aangetoond door een lichte bruine of roze ver kleuring De benzeen indicatie is duidelyk afleesbar tegen die achtergrond c Hogere aromatische koolwaterstoffen bijvoorbeeld tolueen xylenen worden aangetoond door een roodachtig bruine verkleuring De gevoeligheidsindicatie is lager dan voor benzeen Meettolerantie Tot 15 voor het gebied vanaf 20 ppm Tot 25 voor het gebied 5 ppm 20 ppm uitgedrukt als relatieve standaardafwijking Opslag en transport Bij maximaal 25 C en indien beschermd tegen licht Vervaldatum zie achterzijde van de verpakking Veiligheidsadvies afvoer Voor het vulmateriaal geldt Gevaaraanduiding R 21 22 34 Veiligheidsadvies S 2 24 25 26 28 water Ervoor zorgen dat er geen proefbuisjes in handen van onbevoegden kunnen komen Bij de afvoer dienen de desbetreffende wettelijke bepalingen in acht te worden genomen Analysr r Ed AUER GHz Artikelnummer D5085816 Brugsanvisning