Microhmímetro digital Digital micro-ohmmeter

image

Contents

1. 02 o E olf os O Or ee e g ollt Or x 9 o Ou circuTor H FUSE POWER CORD connector ON OFF switch Battery charge LED B Current terminal C Potential terminal P Potential terminal P B Current terminal C B RS 232 output ALPHANUMERIC DISPLAY that shows both the measured resistance value and user s messages START switch STOP switch HOLD switch It retains the last measurement in the display BATTERY Switch to measure the battery charge condition B TEST CURRENT control Scale and test CURRENT SELECTOR ON led Mains supply MH 10 is manufactured in different versions to be compliant with the mains supply specifications in the destination country Please check the value indi cated in the Control Panel in order to be sure that it is appropriate for the local A C supply Measurement 1 Before turning the equipment on connect the test leads to the item to be measured and to the front panel terminals ELEMENT TO BE MEASURED The alligator clamps in A y G the drawings are only NS EDEN N for illustration The E rra h supplied clamps could Ho OO l gt be different than what s Si dos shown in the drawing 2 Using the CURRENT SELECTOR ch
2. Index Safety Precautions 4 Used symbols 4 Description 6 Operating principle 6 Operating instructions 7 Control panel 7 Mains supply 8 Measurement 8 Messages 9 Some notes about accuracy 11 Battery condition 11 Battery and charger 12 RS 232 output 12 Cleaning 13 Technical specifications 13 Accessories 14 Description The MH 10 micro ohmmeter is a portable microprocessor controlled instrument used to accurately measure very low contact resistances of breakers and switches busbars transformers and engines windings etc with test currents from 1 mA to 10 A both in the laboratory and out in the field e Kelvin architecture four terminal method e Digital reading alphanumeric display e Up to 4 digits readings e Powered by rechargeable battery or mains supply e 1 uQ Resolution e 200 Q Maximum reading Operating principle This device uses the Kelvin Bridge architecture with four terminals avoiding testing leads resistance to cause error during measurement The operator may choose test current and the reading is obtained by comparison through internal high stability standards The result appears in the alphanumeric display that is very easy to read 3 CIRCUTOR Operating instructions Control panel
3. Borne negativo de POTENCIAL P Borne negativo de SALIDA DE CORRIENTE C Salida RS 232 DISPLAY alfanum rico indicador del valor de resistencia bajo ensayo y de avisos al usuario START Tecla pulsadora de inicio del ensayo STOP Tecla pulsadora para finalizar el ensayo HOLD Mantiene congelada en el display la ltima medici n BATTERY Tecla pulsadora para medir el estado de la bater a B TEST CURRENT Control de ajuste de corriente SELECTOR DE RANGOS y de corrientes ON Led de encendido O Alimentaci n El MH 10 se fabrica en diferentes versiones para que su alimentaci n sea com patible con la que se utiliza en el pa s al que est destinado Verifique el valor indicado en el panel frontal para asegurarse que sea adecuada para la red de alimentaci n local Operando el equipo 1 Antes de encender el equipo conecte las puntas de prueba al elemento a medir y a los bornes del panel frontal Seleccione el rango y la corriente que utilizar en la medici n con la llave del SELECTOR DE RANGOS ELEMENTO A MEDIR Los terminales coco drilo en el dibujo son meramente ilustrativos i G pudiendo haber dife la SS rencias entre stos y af Ho Hh los que verdadera HO O0 l o mente acompa an al i APS e equipo 2 Determine el tipo de alimentaci n a usar Si fuera con bater a pase al pun
4. A CIRCUTOR MH 10 Digital micro ohmmeter User s Guide p 03 Guide p 03 Microhmimetro digital Guia del Usu rio p 15 del Usu rio p 15 MH 10 Digital micro ohmmeter User s Guide GU 1081 03031601 A Safety Precautions e This equipment should be operated only by qualified and duly trained people closely observing the corresponding safety regulations and instructions contained in the present User Guide It should be checked that the item to be measured is voltage free Before starting with the measurements be sure that the battery is well charged and that the line voltage is between specified limits Do not connect or disconnect the test leads during the measurement e There are no adjustable parts or parts that can be replaced by the user within the equipment Taking out the Control Panel in order to have an access to the internal parts may be dangerous as there are high voltages inside capable of causing fatal accidents Cleaning of this instrument should be carried out using a soft cleaning anti static liquid after verifying that it doesn t attack the plastic parts used in the case and in the Control Panel of this equipment This equipment should be used only by a trained and competent person strictly applying suitable safety rules Used symbols Caution refer to User Guide C Equipment complies with current EU Directives 3 CIRCUTOR
5. Para apagarla oprima la misma tecla 11 Para finalizar la medici n oprima la tecla STOP No apague el equipo con la llave ON OFF sin antes haber oprimido STOP B Cuando termine todas las mediciones apague el equipo con la llave ON OFF Precauci n Nunca conecte o desconecte las puntas de prueba con el equipo en funcio namiento Si tuviera que realizar alguna modificaci n en la conexi n se deber hacer con el equipo apagado Mensajes del display CIRCUTOR MH 10 Cuando se enciende el equipo con la llave ON OFF el DISPLAY indicar durante unos segundos ese mensaje de presentaci n WAIT Indica que el equipo est buscando la mejor condici n de medici n PRESS START Indica que el equipo est en condiciones de iniciar un ensayo para lo cual el operador debe oprimir la tecla START LOW CURRENT Este aviso indica que la corriente de prueba es insuficiente para realizar la medici n Se debe girar el control TEST CURRENT en sentido horario para aumentar a corriente Si bien la medici n es viable con corrientes a partir del 10 de la corriente nominal seleccionada la exactitud especificada se obtiene con corrientes entre el 80 y el 100 de la nominal OVERRANGE Indica que la resistencia medida supera el m ximo de la escala seleccionada H Indica que el valor que se est mostrando es el que fue retenido en el instante en que se oprimi la tecla HOLD BAT Indica que la carga de la bater a es
6. insuficiente debe recargarse 3 CIRCUTOR Consideraciones acerca de la exactitud La exactitud especificada se obtiene cuando la corriente de ensayo est entre 80 y 100 del valor nominal Para corrientes menores la medici n es solo indicativa Cuando se sospecha que puede existir diferencia de temperatura entre los puntos de contacto con el objeto a medir lo que puede determinar la presencia de tensiones termoel ctricas es necesario realizar dos mediciones invirtiendo en la segunda los cables de corriente y por lo tanto el sentido de circulaci n de la corriente a trav s de la resistencia que est siendo medida No deben invertirse los cables de potencial El valor a ser registrado ser el prome dio entre los valores con corriente en un sentido y otro corriente directa e in versa El MH 10 posee un sistema de auto compensaci n que elimina automa ticamente cualquier error producido por offset interno Estado de la bater a Esta operaci n se puede realizar antes o durante la medici n de resistencia Para eso se debe oprimir la tecla BATTERY mientras el equipo est encen dido La indicaci n de barras en el DISPLAY indicar 100 si la bater a est buena Si aparece la indicaci n BAT en el display significa que la bater a est descargada y debe por lo tanto ser cargada Bater a y cargador Descripci n de la bater a El micro ohmimetro CIRCUTOR MH 10 utiliza para su alimentaci n una bater a reca
7. arto de vuelta en senti do antihorario hasta sentir que est destrabado y que el resorte interno empuja hacia afuera al fusible Luego de verificar si el mismo est abierto puede subs tituirse por otro de id nticas caracter sticas Fusible Schurter modelo SPT 5 X 20 Time lag 5A 250V High breaking capacity H 3 CIRCUTOR Especificaciones t cnicas Corrientes de prueba nomi nal Rangos de medici n de resistencia Resoluci n Tensi n de prueba Principio de medici n Exactitud b sica Prestaciones avanzadas Salida serial de datos Protecci n contra agentes ambientales Caracter sticas de seguridad Compatibilidad electromag n tica E M C Inmunidad electrost tica Alimentaci n 1mA 10 mA 100 mA 1 A 10 A Cada corriente puede ser ajustada entre 0 y 100 de su valor nomi nal 0 2000 uQ 10 A 0 20 ma 10 A 0 200 mQ 1 A 0 2000 ma 100 mA 0 20 Q 10 mA 0 200 2 1 mA 14QQ10A Hasta 10 Vc c 1 A a circuito abierto Configuraci n de Kelvin cuatro terminales 0 2 del valor medido 2 d gitos Lectura digital directa de los valores de resistencia medidos en el visor alfanum rico con hasta 4 d gi tos Las mediciones se obtienen r pidamente y con gran exactitud RS 232 4800 bps Permite registrar las mediciones en una impresora serial en una computadora de mano o Lap top o un colector de datos IP54 con la tapa cerrada Cumple los requerimie
8. ch Precaution Do not connect or disconnect the test leads during the measurement Messages CIRCUTOR MH 10 When turning the equipment on using the ON OFF switch this introductory message appears for a while During that time the equipment carries out some functional checking WAIT This message appears each time the equipment needs to adjust any parameter in order to optimize the readings PRESS START The equipment is ready to start a measurement thus the operator has to press the STARTO button LOW CURRENT It shows that the test current is not enough to carry out the reading It appears at the beginning of each test and it keeps on being there up to the operator rotates the TEST CURRENT control clockwise as necessary for the test current to be higher than 10 of the nominal current in the scale The inappropriate con nection of the cables may cause a difficult circulation of test current If this mes sage keeps on being displayed please check that the current cables are con nected appropriately OVERRANGE lt indicates that the measured resistance is higher than the maximum value readable in the selected scale H Indicates that the value is the one retained in the memory when pressing the HOLD button BAT lt shows that the battery is quite discharged The available energy is enough to work during a few minutes only It is necessary the battery to be recharged 3 CIRCUTOR Some notes about accu
9. e with IEC 61326 1 In accordance with IEC 1000 4 2 Internal battery powered Rechargeable battery sealed lead 12V 7Ah or mains MH 10 is manufactured in different versions to be compliant with the mains supply specifications in the destination country Please check the value indicated in the Control Panel in order to be sure that it is appro priate for the local A C supply gt 5 C to 50 C 25 C to 65 C 95 RH non condensing 3000m Approx 8 8 kg including battery and accessories 378 x 308 x 175mm Combined current and potential leads with alligator clips 1 8m 2 e Charger Power cord e RS 232 cable e Operating instructions e Protective bag for instrument and cables MH 10 Micro ohmimetro digital Gu a del Usuario A Precauciones de Seguridad Estos equipos deben ser operados nicamente por personas calificadas debidamente entrenadas respetando rigurosamente las normas de seguridad pertinentes y las indi caciones contenidas en la actual gu a del usuario e Se debe verificar que el elemento a medir no est energizado e Antes de comenzar las mediciones se debe verificar que la bater a est con carga y que la tensi n de l nea est entre los l mites especificados No conecte o desconecte las puntas de prueba durante una medici n No existen partes ajustables o reemplazables por el usuario en el interior del equipo Retirar la tapa para acceder a su
10. ifying that it doesn t affect the plastic parts used in the case and in the Control Panel of this equipment A Replacement fuse To check the instrument FUSE remove it with a screw driver If the fuse is ruptured replace it by another with the following specifications Fuse Schurter model SPT 5x20 Time lag 5A 250V High breaking capacity H Technical specifications Test currents Resistance ranges Resolution Output voltage Measurement principle Basic accuracy Advanced features Serial data output Environmental protection 1mA 10 mA 100 mA 1 A 10 A Each current may be continuously adjustable from 0 to 100 0 2000 uQ 10 A 0 20 ma 10 A 0 200 mQ 1 A 0 2000 ma 100 mA 0 20 2 10 mA 0 200 Q 1 mA 14QQ10A Up to 10 Vc c 1 A open circuit Four terminal Kelvin type 0 2 of reading 2 digits Digital direct reading of very low resistances in the alphanumerical display with up to 4 digits Very fast and accurate measurements RS 232 4800 bps Suitable for data collection in an external serial printer computer or data logger IP54 with closed lid le Safety class E M C Electrostatic immunity Power supply Built in battery charger Operating temperature range Storage temperature range Humidity range Maximum altitude Weight Dimensions Accessories Meets the requirements of IEC61010 1 1990 IEC 61010 1 1992 amendment 2 In accordanc
11. interior es peligroso porque existen tensiones eleva das capaces de provocar accidentes fatales La limpieza de este instrumento se debe realizar empleando un l quido limpiador suave con anti est tico verificando previamente que no ataca los materiales pl sticos utiliza dos Este equipo debe ser operado nicamente por personas calificadas apli cando rigurosamente las normas de seguridad pertinentes S mbolos utilizados en el equipo A Atenci n referirse a la guia del usuario C El equipo est conforme con las directrices actuales de la U E 2 QU 3 CIRCUTOR ndice Precauciones de Seguridad 16 S mbolos utilizados en el equipo 16 Descripci n 18 Principio de funcionamiento 18 Instrucciones de uso 19 Funci n de los controles del panel 19 Alimentaci n 20 Operando el equipo 20 Mensajes del display 22 Consideraciones acerca de la exactitud 23 Estado de la bater a 23 Bater a y cargador 23 Salida RS 232 24 Limpieza 24 Especificaciones t cnicas 25 Accesorios 26 Descripci n El micro ohm metro digital MH 10 es un instrumento port til controlado por microprocesador destinado a medir con alta precisi n resistencias muy bajas de contacto de disyuntores llaves barras conductoras bobinados de transfor madores y motores etc con corrientes de prueba desde 1 mA hasta 10 A Entre sus principales caracter sticas se destacan las siguientes Co
12. ntos de las normas IEC61010 1 1990 IEC 61010 1 1992 enmienda 2 De acuerdo a la norma IEC 61326 1 De acuerdo a la norma IEC 1000 4 2 Mediante su bater a interna recargable de 12V 7Aho por la red T Cargador de bater a incorpo rado Temperatura de operaci n Temperatura de almacenaje Humedad Altura m xima de operaci n Peso Dimensiones Accesorios El MH 10 se fabrica en diferentes versiones para que su alimentaci n sea compatible con la que se utiliza en el pa s al que est destinado Verifique el valor indica do en el panel frontal para asegurarse que sea ade cuada para la red de alimentaci n local gt 5 C a 50 C 25 C a 65 C 95 HRA sin condensaci n 3000m sobre el nivel del mar Aprox 8 8 kg incluyendo los accesorios 378 x 308 x 175mm e Puntas de prueba combinadas corriente y potencial 1 80m 2 Bolsa para transporte e Cable de alimentaci n e Cable para RS 232 e Manual del operador
13. ntrolado por microprocesador e Utiliza el m todo de los 4 terminales e Lectura digital en display alfanum rico e Indicaci n de hasta 4 d gitos e Bater a recargable y alimentaci n por red Memoria para retenci n de lectura Corriente de prueba desde 1 mA hasta 10 A e Exactitud t pica 0 2 e Resoluci n de 1 uQ e Lectura m xima de 200 Q e Protecci n t rmica e Salida RS 232 Principio de funcionamiento Utiliza la arquitectura del Puente de Kelvin de cuatro terminales evitando que la resistencia propia de los cables de prueba introduzcan errores en las medi ciones La corriente de prueba es seleccionable por el operador y la indicaci n se obtiene por comparaci n con patrones internos de alta estabilidad El resul tado es presentado en un visor alfanum rico de f cil lectura 3 CIRCUTOR Instrucciones de uso Funci n de los controles del panel 0000080 66 Q00 O 8088 O2 BG CIRCUTOR T A FUSIBLE ENTRADA DE TENSI N de red ON OFF Llave de encendido Led indicador de CARGA DE BATER A B Borne positivo de SALIDA DE CORRIENTE C B Borne positivo de POTENCIAL P
14. oose the range and the current to be used 3 Choose the power supply to use lf you are going to use the battery ad vance to the following point If you are going to use the mains supply plug the power cord into the connector 4 Switch the equipment on using the ON OFF O 3 CIRCUTOR 5 The PRESS START message will appear showing that measurement can be started Press the START switch Depending on the position of the TEST CURRENT control the LOW CURRENT message will turn up 6 Turning the TEST CURRENT control clockwise increases the current Adjust this control until obtaining the desired value or until the current indi cator bar graph indicates 100 The bar graph will show the test current value as a percentage of the nominal value selected by using the CUR RENT SELECTOR 7 The lowest current for measuring is 10 of the scale nominal value It is important to consider that the measurement errors increase while test cur rent decreases The error is specified for test currents higher than 80 8 The DISPLAY will show the resistance value measured and the corre sponding unit Q ohms m milli ohms or uQ micro ohms 9 That value can be retained in the display by pressing the HOLD key Pressing this key again the value will be erased 10 Press the STOP switch in order to finish the measurement 11 Finally when finishing measurements turn the equipment off using the ON OFF swit
15. racy In order to obtain the specified accuracy the operator has to adjust the test current to a value higher than the 80 of the nominal value If it were neces sary it is possible to use a lower current but by doing this the accuracy will be affected MH 10 has an auto compensation system that automatically eliminates the error produced by internal offset Thus it is not necessary to carry out measurements by reversing the polarity in order to compute the average value Nevertheless if the operator suspect that there is a difference of temperature between the con tact points that would can generate thermoelectric voltages it is necessary to carry out two measurements by reversing the current cables and so the circula tion sense of the current through the resistance under measurement The re sistance value to be measured will be the average between the values in one sense and in the contrary direct and inverse current Battery condition The charge condition of the battery can be verified before or during the resis tance measurement In order to achieve that the operator has to press the BATTERYO key while the equipment is turned on The bar graph shows re maining charge as a percentile value If during measurement the charge of the battery achieves a critical level the display will show the BAT message notifying that the charge level is low After a few minutes the measurement will be auto matically interrupted in order to preser
16. rgable herm tica de 12V 7Ah o con tensi n de red Cargador de bater a Este equipo posee incorporado un circuito inteligente que controla la carga da bater a Para cargar la bater a siga el siguiente procedimiento e Verifique que la llave ON OFF est en OFF e Conecte el equipo a la energ a el ctrica e Despu s de un instante el indicador luminoso led CARGA DE BATER AO quedar encendido con luz roja hasta completar la carga cuando el indicador pasar a luz verde y permanecer as hasta que el equipo sea desconectado del toma de corriente gt Salida RS 232 5 32 Al vette la El equipo posee en el panel frontal una salida RS 232 que puede ser utilizada para registro de las mediciones en una impresora serial o un colector de datos Las salidas son las siguientes Pin 2 Rx Pin 3 Tx Pin 5 Gnd Velocidad de transferencia 4800 bps 8bits sin paridad 1 stop bit 8 n 1 Nota Para asegurar la compatibilidad con las impresoras disponibles en el mercado las unidades de resistencia se representan con los siguientes s mbolos UR micro ohm mR mili ohm R ohm Limpieza Debe realizarse empleando un l quido limpiador suave con anti est tico verifi cando previamente que no ataca los materiales pl sticos utilizados A Cambio de fusible Para substituir el fusible debe utilizarse un destornillador de peque o porte y girar la tapa del portafusible aproximadamente un cu
17. to siguiente Si fuera con alimentaci n a trav s de la red conecte el cable co rrespondiente en la ENTRADA DE TENSI N 3 Encienda el equipo con la llave ON OFF a 3 CIRCUTOR 4 El DISPLAYO del equipo exhibir el mensaje de presentaci n CIRCUTOR MH 10 Esto indica que el microprocesador ya realiz una verificaci n en las diferentes partes del circuito y est listo para continuar 5 En seguida aparecer el mensaje WAIT y luego PRESS START 6 Oprima la tecla START 7 Siel ajuste de corriente TEST CURRENT estuviera en el inicio del reco rrido totalmente girado en el sentido antihorario la corriente ser insufi ciente para medir la resistencia y aparecer el mensaje LOW CURRENT Girando el control TEST CURRENT en sentido horario aumente la co rriente hasta alcanzar el valor estable deseado medido en el indicador de corriente por barras bar graph La indicaci n est expresada como un porcentual del valor nominal de la corriente seleccionada por el SELEC TOR DE RANGOS La lectura de la resistencia es independiente de la corriente provista por el equipo siempre que la misma sea superior al 80 del valor nominal de la escala 8 Completado este proceso el DISPLAY indicar el valor de resistencia medido 9 La unidad de la resistencia medida estar expresada en Q ohms mQ mili ohms o en uQ micro ohms 10 Ese valor podra ser retenido en el DISPLAY simplemente presionando la tecla HOLD
18. ve the battery from a deep discharge that is prejudicial for its expected useful life Battery and charger Battery description The CIRCUTOR MH 10 micro ohmmeter uses a sealed rechargeable lead acid 12V 7Ah battery At the end of the useful life that battery has to be recy cled or disposed of properly in order to take care of the environment Battery charger The built in battery charger is always active when the equipment is connected to the mains supply even if the ON OFF switch is turned off Charging procedure e Check that the ON OFF key is OFF e Connect the equipment to the mains supply e The indicator will keep on lightning with a red light up to completing the charge At that point it will change to a green light being like this up to the equipment disconnection from the mains supply RS 232 output The equipment has an RS 232 output in the control panel that can be used to register measurements in a serial printer or data collector The outputs are the following ones Pin 2 Rx Pin 3 Tx Pin 5 Gnd Rate 4800 bps 8 bits no parity 1 stop bit 8 n 1 Note In order to assure the compatibility with most printers available in the market the resistance units are shown with the following symbols uR micro ohm mR milli ohm R ohm a Cleaning 3 CIRCUTOR Cleaning of this instrument should be carried out using a soft cleaning anti static liquid after ver

Download Pdf Manuals

image

Related Search

Related Contents

Ateca AT320BP171 flat panel floorstand  Havis-Shields Cold Cathode Compartment Light KR-CCL Series User's Manual  SERVICE MANUAL  UM - Plumbase  Affiliate-Marketing Module for Magento  2. Primeira utilização do Tablet PC  Descargar Manual - Siisa  PULSEBOX NxtG - AxeMotion CNC Controller  PUMY-P125YMA PUMY-125YMA  Perform 2 Slot ATCA AC Shelf User Manual  