Home

Model: - Husky Power Washer, Home Depot Pressure Washer

image

Contents

1. breaker Circuit breaker trips or fuse blown in Circuit Overload Check that the circuit is rated 15 amps fuse box or greater Disconnect all loads on the circuit Extension cord too long or wire size Use proper extension cord as too small recommended in Operator s Manual Nozzle partially blocked Clean nozzle as instructed in Section 5 2 Excessive pressure Reduce pressure by using pressure adjustment knob 18 POWERWASHER PROBLEM POSSIBLE CAUSE CORRECTION GFCI trips repeatedly Incorrect voltage Internal short See Section 3 3 Call Customer Service Department Water or oil leaking from bottom of pump A small amount of leakage is normal If excessive leaking occurs call Powerwasher FAIP Customer Service Department Pressure increases when gun is closed Bypass valve not operating properly Call Customer Service Department Motor running but pump not building maximum pressure or has irregular pressure No intake of chemicals Faucet closed Unit has been stored in freezing temperatures Water inlet screen clogged Air in pump Adjustable pressure knob not set to maximum position Suction or discharge valves clogged or worn out By pass valve not operating effectively Injection tube not securely inserted into pressure washer Tube cracked or split Wrong Nozzle setting Nozzle blocked Injection tube strainer clogged Dried chemicals in injector Open fauc
2. I O OFF 4 2 HIGH PRESSURE LOW PRESSURE see the picture in the next page CAUTION Do not move the nozzle to AN adjust pressure while the trigger is WARNING squeezed The high pressure nozzle position is intended for RENA When high pressure is required grasp collar and slide the collar and nozzle toward the gun NOTE Make sure the collar is pulled to the extreme rear position to lock the nozzle in the high pressure position 4 2 ALTA PRESI N BAJA PRESI N ver la figura de la p gina siguiente ATENCI N No desplacen la boquilla para regular la presi n cuando el gatillo ATENCI N est presionado La posici n de la boquilla de alta presi n baja presi n es ideal para la limpieza Gian se requiere presi n alta sostener y hacer desplazar la abrazadera brida y la boquilla hacia la pistola NOTA Seg rense de que la abrazadera brida est toda atr s para cerrar la boquilla en la posici n de aja presi n XN N PRESSURE HIGH PRESSURE When low pressure is require grasp collar and slide collar and nozzle away from the gun 11 Cuando se requiere alta presi n sostener y hacer desplazar la abrazadera brida y la boquilla lejos de la pistola POWERWASHER ee j T Dy q LOW PRESSURE LOW PRESSURE S 4 3 ADJUSTABLE
3. POWERWASHER Operator s Manual Manual del Operador Model HD1600 W TSIS ERA AR a VOW Warranty Registration by Internet Registro Garantia mediante Internet Internet Address www hdpowerwasher com SEE OUR WEB SITE FOR REPLACEMENT MISSING PARTS AND TROUBLESHOOTING VISITEN NUESTRO SITIO WEB PARA SUSTITUCIONES Y O PARTES FALTANTES HELP LINE 1 888 550 1606 READ AND SAVE THESE INSTRUCTIONS LEER Y CONSERVAR ESTA INSTRUCCIONES POWERWASHER INDEX 1 0 SAFETY AND OPERATION RULES page 3 2 0SAFETY FEATURES 0 see see page 7 3 0 INSTALLATION uses sesse ei ss sege page 8 3 1 HIGH PRESSURE HOSE page 8 3 2 WATER CONNECTI N page 8 3 3 POWER SUPPLY CONNECTION si moetesinssssiess ie page 9 4 0 OPERATING INSTRUCTIONS page 10 4 1 START UP PROCEDURE sesse sees page 10 4 2 HIGH PRESSURE LOW PRESSURE sscanteinesdanaactnsasenns page 11 4 3 ADJUSTABLE SPRAY OSES io ee aE ee page 12 4 4 HIGH PRESSURE TURBO SPRAY ese page 12 4 5 USE OF CHEMICAL assets page 13 4 6 CLEANING TECHNIQUES page 13 4 7 END OF OPERATION page 14 5 0 USER MAINTENANCE page 15 3 1 CONNECTIONS ee page 15 NI A N page 15 5 3 LUBRICATION ee ee ee page 16 5 4 WATER SCREEN occiso page 16 5 5 COOLING SYSTEM ses gas eed page 16 6 0 MOVING AND STORAGE INSTRUCTIONS ee page 17 6 1 AFTER EXTENDED STORAGE page 17 7 O TROUBLESHOOTING asses seeks see page 18
4. n Caudal de inyecci n Agua de introducci n Alta presi n del ngulo del de 20 a 100 psi 2 4 Agua fr a de grifo chorro de la boquilla 0 60 Baja presi n del ngulo del chorro de la boquilla O 90 Chorro boquilla turbo 30 grados Please Call Us First If there are missing or damaged parts THE STORE Our Customer Service Department is available to help with any problems and operational questions Our toll free number 1 888 550 1606 SEE OUR WEB SITE FOR REPLACEMENT AND OR MISSING PARTS DO NOT RETURN THIS PRODUCT TO Llamennos inmediatamente Si faltan piezas o hay piezas da adas NO MANDEN SU EQUIPO AL ALMACEN Nuestra Oficina Asistencia Clientes est siempre disponible para ayudarles para resolver cualquier problema o para cuestiones operativas Nuestro numero gratuito interurbano es 1 888 550 1606 VISITEN NUESTRO SITIO WEB PARA SUSTITUCIONES Y O PARTES FALTANTES 22 POWERWASHER Limited Warranty This product is warranted by us to the original retail consumer against defects in material and workmanship for a period of 1 year on machine 90 days on gun hose assembly from the date of retail purchase and is not transferable This one year warranty applies only to products used in consumer applications This warranty does not apply to rental applications Please complete and return the enclosed Customer Information Card so that we can reach you in the
5. unlikely event a safety recall is needed Register by Internet at www hdpowerwasher com Return of this card is not required to validate this warranty WHAT IS COVERED Replacement parts and labor WHAT IS NOT COVERED This warranty does not include such parts as nozzles which must be replace as part of normal maintenance of the equipment rather than as the result of a defect Transportation charges to warranty center for defective products Transportation charges to consumer for repaired products Damages caused by abuse accident improper repair or failure to perform normal maintenance Use of improper chemicals or noncompliance with the operators manuals instructions Sales outside of the United States or Ca nada Any other expense including consequential damages incidental damages or incidental expenses including damage to property Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty does not cover damage resulting from failure to observe any of the following conditions 1 The inlet water pressure must be between 20 and 100 p s i The inlet water temperature must not exceed 90 degree F 2 The unit should not be stored in areas where temperatures may drop below 32 degrees F 3 IMPLIED WARRANTIES Any implied warranties including the implied Warranties of Merchantability and fitness for a particular
6. 0 MANIPULACI N Y ALMACENAMIENTO ATENCI N Almacenen la hidrolimpiadora en un local cuya tempe ratura no descienda por debajo de los 32 F En el caso de congelamiento la 2 bomba de este equipo est sujeta a da o ATENCION permanente LOS DANOS PROVOCADOS POR El HIELO NO ESTAN CUBIERTOS POR LA GARANTIA Si almacenan la hidrolimpiadora en un local donde la temperatura es inferior a los 32 F pueden disminuir el riesgo de da o del equipo siguiendo el siguiente e 1 Detengan la hidrolimpiadora y desconecten la manguera de alimentaci n y la de alta presi n Presionen el gatillo de la pistola de descarga para hacer salir toda el agua del lanzador y de la manguera Pongan nuevamente en marcha la hidrolimpiadora y d jenla en funcionamiento durante un breve per odo unos 5 segundos hasta que saldr el agua por la salida de la alta presi n DESPU S DE UN ALMACENAMIENTO PROLONGADO 6 1 Cuando no es utilizada durante mucho tiempo se podr an formar en la bomba dep sitos calc reos Ello podr a implicar que el motor no funcione correctamente o que directamente no funcione Extraigan los dep sitos calc reos de la tuber a e Conecten la m quina a la alimentaci n del agua y enjuaguen No introduzcan el enchufe en el conector principal Para evitar la sobrecarga el ctrica giren el eje motor manualmente POWERWASHER Proceed as follows Efectjen las siguientes operaciones Disconnect uni
7. 8 OREPLACEMENT PARTS AND ACCESSORIES soci cnsiinesisuoricstoasnsvanendes page 21 9 OTECHNICAL DATA eee page 22 INDICE 1 0 NORMAS OPERATIVAS Y DE SEGURIDAD osse Eg Ek N ee pag 3 2 0 CARACTERISTICAS RELATIVAS A LA SEGURIDAD cociciciociciciccicacicoss pag 7 3 0 INSTALACI N ee ee ee pag 8 3 1 MANGUERA DE ALTA PRESI N ee ee pag 8 3 2 CONEXI N DEL AGUA pag 8 3 3 ENLACE DE LA ALIMENTACI N EL CTRICA pag 9 4 0 INSTRUCCIONES DE USO pag 10 4 1 PROCEDIMIENTO DE PUESTA EN MARCHA 0 0000000 pag 10 4 2 CHORRO DE ALTA PRESI N TURBO pag 11 4 3 BOQUILLA CHORRO REGULABLE vsccacoicrssc citaci n pag 12 4 4 CHORRO DE ALTA PRESI N TURBO pag 12 4 5 USO DE PRODUCTOS QU MICOS cociciciccicocicicccicicincnan n pag 13 4 6 T CNICAS DE LIMPIEZA pag 13 4 7 FINALIZACI N DE LA OPERACI N uecscscscsseseeee pag 14 5 0 MANUTENCI N USUARIO pag 15 3 1 CONEXIONES sin cosnisveiiensinioondsbipns pag 15 22 BO ost pag 15 5 3 LUBRICACI N cocooociciciciococacicicoss pag 16 5 4 PANTALLA AGUA esse pag 16 5 5 SISTEMA DE REFRIGERACI N pag 16 6 0 MANIPULACI N Y ALMACENAMIENTO sesse pag 17 6 1 DESPUES DE UN ALMACENAMIENTO PROLONGADO ee ee pag 17 7 0 LOCALIZACION DE LAS AVER AS ee ee ee ee ee pag 18 8 OPIEZAS DE REPUESTO Y ACCESORIOS comision pag 21 9 0 DATOS T CNICOS cocooccccccicicccicninoo pag 22 POWERWAS
8. DE DESENGRASANTE A BASE DE JABON 1 Apliquen la soluci n de jab n de la hidrolimpiadora sobre una superficie de trabajo SECA NOTA NO SE ACONSEJA MOJAR LA SUPERFICIE ANTES PUESTO QUE DILUYE EL DETERGENTE Y REDUCE SU CAPACIDAD DE LIMPIEZA Ante la presencia de una superficie vertical apliquen el jab n horizontalmente comenzando por la parte baja para evitar estriados Antes de enjuagar dejen el producto qu mico sobre la superficie durante un bre ve lapso de tiempo ATENCI N Si se deja secar el jab n las superficies pintadas podr an da arse Laven y sequen una ATENCI N Peque a secci n por vez No trabajen sobre superficies calientes o bajo la luz directa del sol 3 Enjuaguen con agua limpia y con alta presi n Sobre as superficies verticales comiencen a enjuagar antes desde la parte baja hacia la parte alta y luego vice versa Tengan la boquilla a 6 8 pulgadas de la su perficie de trabajo con un ngulo de 45 utilizando el chorro turbo como si fuera una herramienta para pelar en lugar de cepillo de acero NOTA Aseg rense que el sistema de inyecci n de productos qu micos est completamente limpio antes de cambiar productos qu micos APLICACI N DE LA CERA 1 Despu s de haber limpiado apliquen la cera con la hidrolimpiadora regulada sobre la baja presi n Coloquen la cera dentro el dep sito del liquido detergente 2 Apliquen la cera en un estrato uniforme Apliquen sobre superficies mojadas
9. SPRAY NOZZLE The adjustable spray nozzle can adjust spray from fan to pencil point in both the ul and low pressure positions The spray is adjusted by turning the nozzle A CAUTION CAUTION The pencil point spray adjustment is very aggressive We recommend that for most cleaning applications a twenty degree 20 spray angle be used to avoid damage to the surface being sprayed NOTE The pressure of the spray on the surface you are cleaning increases as you move the wand closer to the surface To increase angle to a fan spray turn counterclockwise lt A To decrease angle to pencil point spray turn clockwise 4 4 HIGH PRESSURE TURBO SPRAY CAUTION Do not move the nozzle to CAUTION Cdlust pressure The high pressure turbo nozzle position is intended for maximum cleaning effect Keep the spray lance min 6 to 8 away from the cleaning surface at all times 4 3 BOQUILLA CHORRO REGULABLE La boquilla de chorro regulable permite regular el chorro desde el ventilador hasta la punta del l piz tanto en posici n de alta como de baja presi n El chorro se regula girando la boquilla ATENCI N la regulaci n del chorro de la punta del l piz puede dar resultados agresivos corrosivos Aconsejamos utilizar para la mayor parte de las gt aplicaciones de limpieza un ngulo de ATENTIGI chema de veinte peras 20 Dae no da ar las superficies donde se necesita utilizar
10. la boquilla al lanzador NOTA Atornillar completamente las boquillas en el lanzador hasta cerrar completamente ver dibujo Hacer arrancar nuevamente la hidrolimpiadora y bajar el gatillo de la pistola de chorro Si la sr esta a n bloqueada o parcialmente bloqueada repitan dichas operaciones desde el punto 1 hasta el punto 4 POWERWASHER 5 3 LUBRICATION The pressure washer is designed with a permanent lubrication system Conventional oil check and oil changes are not necessary NOTE N CASE OF OU LEAKAGE CONTACT THE HD POWERWASHER CUSTOMER SERVICE DEPARTMENT CONCERNING REPAIR A SMALL AMOUNT OF Ol LEAKAGE IS NORMAL 5 4 WATER SCREEN The pressure washer is equipped with a water inlet screen to protect the pump A CAUTION CAUTION f the screen is not kept clean the How of water to the pressure washer will be restricted and the pump may be damaged To clean inner water screen remove quick connect and remove the filter screen from the pump inlet see page 6 item 13 Backflush screen to clean Replace screen and quick connect immediately to prevent any foreign matter from entering the pump CAUTION Do not damage the screen while removing or cleaning Any foreign particles entering the pump may damage the pump A CAUTION 5 5 COOLING SYSTEM The air vents located in and around the pressure washer must be kept clean and free of any obstructions to ensure proper air cooling of the motor during ope
11. of date of retail purchase Sales slip Call our Customer Service Department at 1 888 550 1606 for a return authorization number or unit will be refused Package and return the product transportation charges prepaid to POWERWASHER Attn Warranty Service Dept 509 S Vermont St Palatine Illinois 60067 To the extent any provision of this warranty is prohibited by federal state or municipal law and cannot be preempted It shall not be applicable This warranty gives you specific rights and you may also have other rights which vary from state to state POWERWASHER 2455 PACES FERRY RD N W ATLANTA GEORGIA 30339 4024 1 888 550 1606 Internet Address www hdpowerwasher com Warranty Registration via Internet COMO OBTENER LA GARANTIA anexen al producto su nombre domicilio descripci n del problema n mero de tel fono y comprobante de la fecha de la compra al por menor recibo de venta Llamen por tel fono a nuestra Oficina de Asistencia a los Clientes al No 1 888 550 1606 para recibir un n mero de autorizaci n para la restituci n de lo con trario el equipo no ser aceptado Embalen y restituyan el producto gastos de transporte prepagados a POWERWASHER Attn Oficina Asistencia en Garant a 509 S Vermont St Palatine Illinois 60067 Cualquiera de las cl usulas de la presente garant a no ser aplicable en el caso de prohibici n por parte de un Estado o de una administraci n comunal federa
12. purpose are limited in duration to one 1 year from the date of retail purchase Some states do not allow limitations on how long an implied warranty lasts so that above limitation may not apply to you 23 Garant a limitada Este producto est garantizado por nosotros al consumidor minorista original contra defectos de material y de fabricaci n por un per odo de un a o en la m quina y por un per odo de 90 d as en el grupo pistola tubo a partir de la fecha de compra al por menor y no es transferible La garantia de un a o se refiere solamente a los productos usados en aplicaciones del cliente La presente garant a no se refiere a aplicaciones de alquiler Les rogamos ables y restituyan la anexa Ficha in formativa del Cliente para poder llegar hasta Uds en la improbable eventualidad de que se haga necesario reclamar la mercancia por motivos de seguridad Re gistro por Internet al sitio www hdpowerwasher com La restituci n de dicha ficha no es necesaria a los fines de la validez de la presente garant a LA GARANT A CUBRE piezas en substituci n y mano de obra EXCLUSIONES DE LA COBERTURA EN GARANTIA la presente garant a no incluye aquellas piezas que como las boquillas deben ser substituidas como piezas de normal manutenci n del equipo y no como consecuencia de un defecto Los gastos por transporte a un centro autorizado por los productos defectuosos Los gastos de transporte al consumidor por los prod
13. s lo piezas de repuesto del mismo tipo Para una substituci n correcta contacten la Oficina de Asistencia Clientes No se aconseja el uso de extensiones si no est n introducidas en una toma protegida por el interruptor diferencial autom tico de seguridad Cualquier extensi n utilizada debe ser del tipo 14AWG y la longitud no debe superar los 50 pies con el fin de prevenir una excesiva dispersi n de tensi n Utilicen s lo extensiones ara uso exterior Tales extensiones est n se aladas con E siguiente frase Id neas para uso exterior almacenar en lugar cerrado cuando no es utilizada POWERWASHER 4 0 OPERATING INSTRUCTIONS A WARNING WARNING Risk of injection or injury Do not direct discharge stream at persons 4 1 START UP PROCEDURE 1 Make sure water supply is connected and turned on Make sure the unit is plugged in and the GFCI HAS BEEN RESET Release gun safety if locked INSTRUCCIONES DE USO 4 0 N IMPORTANTE Riesgo de impregnaci n o de da os NO descarguen el flujo sobre ATENCI N as personas 4 1 PROCEDIMIENTO DE PUESTA EN MARCHA 1 Aseg rense de que la alimentaci n del agua est conectada 2 Aseg rense de que el enchufe del equipo est conectado y que el GFCI HAYA SIDO RESETEADO Liberen la seguridad de la pistola si est bloqueada A A Bloqueo de seguridad cerrado B Bloqueo de seguridad abierto 4 Toa
14. unit to OFF position before connecting or disconnecting cord to electrical outlets 5 Water spray must never be directed towards any electric wiring or directly towards the pressure washer machine itself or fatal electric shock may occur 6 Never carry your pressure washer by the cord Do not pull on the cord to disconnect from the outlet 7 To prevent damage the cord should not be crushed placed next to sharp objects or near a heat source 8 This product is provided with a Ground Fault Circuit Interrupter built into the power cord plug If replacement of the plug or cord is seed ie use only identical replacement parts 1 0 NORMAS OPERATIVAS Y DE SEGURIDAD Cuando se trata de un equipo mec nico las precauciones inherentes a la seguridad son esenciales Por ello es necesario adoptar dichas precauciones du rante el uso la transferencia y la manutenci n del equipo mec nico Utilizando los aparatos con el respeto y la cautela requeridos las posibilidades de provocar da os personales disminuir n notablemente Si estas precauciones de seguridad fueren descuidadas o ignoradas se podr an verificar da os a las personas o a equipo Los simbolos que describiremos a continuaci n son utilizados ampliamente en el presente manual Tengan siempre en cuenta dichas precauciones puesto que son esenciales cuando se utiliza el equipo mec nico Es el s mbolo que identifica las instrucciones para procedimientos espec ficos
15. when not in use 3 3 ENLACE DE LA ALIMENTACI N ELECTRICA La hidrolimpiadora est dotada de serie de un cable el ctrico y de un enchufe de alimentaci n con interruptor diferencial autom tico de seguridad GFCI El cable deber ser conectado nicamente a una toma el ctrica instalada en conformidad con las normativas locales de seguridad NOTA la corriente el ctrica deber ser de 120V 60 Hz con un circuito de por lo menos 15 amp A Procedimiento para controlar el GFCI 1 Conectar el GFCI en la toma de alimentaci n 2 Presionar RESET 3 Presionar el bot n TEST Aparecer un indcador de color rojo en RESET 4 Presionar nuevamente RESET antes del uso NOTA GFC debe ser reseteado todas las veces que se conecta la hidrolimpiadora a una toma el ctrica A ATENCI N ATENCI N Controlen el interruptor diferencial autom tico de seguridad GFCI antes del uso No utilicen la hidrolimpiadora si el control efectuado da un resultado negativo A Conecten s lo a una toma con una puesta a tierra id nea No extraigan el enchufe de tierra B Controlen el cable antes del uso Si est da ado no lo utilicen C Mantengan secas y fuera de tierra todas las conexiones No toquen el enchufe con las manos mojadas E La hidrolimpiadora es suministrada con un interruptor diferencial autom tico de seguridad instalado en el enchufe de alimentaci n Si es necesario substituir el enchufe o la toma usen
16. HER 1 0 SAFETY AND OPERATION RULES Safety precautions are essential when any mechanical equipment is involved These precautions are necessary a using storing e peer n mechanical equipment Using this equipment with the respect and caution demanded will considerably lessen the possibilities of personal injury If safety precautions are overlooked or ignored personal injury or property damage may occur The following symbols shown below are used extensively dk this manual Always heed these precautions as they are essential when using any mechanical equipment instructions or procedures which if no N correctly followed could result in perso WARNING nal injury or death AN instructions e which if no strictly observed could result in damage CAUTION to or destruction of equipment This warning symbol identifies specific This caution symbol identifies specific This unit was designed for specific applications It should not be modified and or used for any application other than that which it was designed When using this product basic precautions should always be followed including the WARNING following 1 Read this manual carefully know your equipment Consider the a ae limitations and the potential hazards specific to your unit 2 Outlets with a third pros one are required Do not use without grounded prong 3 Do not touch plug or outlet with wet hands 4 Avoid accidental starts Move switch on
17. L AGUA Machine Inlet gt N K Ve gt of Va Agujero admision mag Garden Hose Manguera flexible jardin Gasket ba Conexion rapida Guarnicion Ig ATTENTION ATENCION Proper water connection Union del agua apropriada 3 0 INSTALLATION 3 0 INSTALACION 3 1 HIGH PRESSURE HOSE 3 1 TUBO DE ALTA PRESI N Remove and discard the water plug 12 parts list before attaching the high pressure da carefully inserting the fitting with the o ring into the high pressure outlet and tighten the da nut by hand 3 2 WATER CONNECTION Before connecting run water through the garden hose not supplied to flush out any foreign matter Attach garden hose to the pressure washer water inlet connection Extraer y desechar el tap n del agua lista piezas de repuesto 12 antes de conectar el tubo de alta presi n introduciendo cuidadosamente la uni n sie ia el O ring adentro de la salida de alta presi n y apretando manualmente la tuerca roscada 3 2 CONEXION DEL AGUA Antes de efectuar la conexi n haga correr el agua en la manguera jardin no incluida en el suministro para hacer salir los materiales extra os Conecten la manguera jard n a la uni n del agujero de introducci n de la hidrolimpiadora de alta presi n POWERWASHER 3 3 POWER SUPPLY CONNECTION The pressure washer is factory equipped with an electrical cord and a Ground Fault Circuit Interrupter GFCI power plug T
18. N 1 888 550 1606 SERVICIO CLIENTES 1 888 550 1606 Code C digo Description Descripcion ACCESSORIES ACCESSORIOS KTRI53187 SOFT BRISTLE HAND BRUSH CEPILLO MANUAL DE CERDAS SUAVES EX1025F 1 EXTENSION HOSE TUBO PROLONGACION REPLACEMENT PARTS PIEZAS DE RECAMBIO IPPR8 1881 HIGH PRESSURE HOSE AND GUN GRUPO PISTOLA Y TUBO DE ALTA ASSEMBLY PRESION LCTE81730 WAND VARIABLE NOZZLE ASSEMBLY GRUPO BOQUILLA VARIABLE CUVR63631 INLET SCREEN EXTERIOR REJILLA ENTRADA EXTERIOR TBAP52985 NOZZLE CLEANER LIMPIADOR BOQUILLA RCVR62829 GARDEN HOSE QUICK COUPLING ADAPTADOR TUBO DE JARDIN LCTE81741 WAND TURBO NOZZLE ASSEMBLY ENSAMBLAJE DE LA BOQUILLA TURBO 21 POWERWASHER 9 0 TECHNICAL DATA 1600 psi MAX Operation Pressure Pump pressure 120V 15 Amps 60 Hz Electrical requirement Electrical cord 35 ft High Pressure Hose 23 ft Flow Rate at 1600 psi 1 6 gpm Minimum Amperage source 15 amp Pressure of inlet water 20 100 psi Injection rate 2 4 Inlet Water Cold Tap Water Nozzle Spray Angle High Pressure O 60 Nozzle Spray Angle Low Pressure 90 Turbo Nozzle Spray 30 ker Tollerances 10 on stated performances 9 0 DATOS TECNICOS 1600 psi MAX Presi n de uso man Presi n bomba 120V 15 Amp 60 Hz Necesidades de electricidad Cable el ctrico 35 pies Manguera alta presi n 23 pies Capacidad a 1600 psi 1 6 gpm Fuente minima de amperaje 15 Amp Preesi n del agua de introducci
19. and resume normal operation after a short period of time GROUND FAULT CIRCUIT INTERRUPTER PROTECTION 2 0 CARACTERISTICAS RELATIVAS A LA SEGURIDAD La hidrolimpiadora de presi n est dotada de un di spositivo de stop que detecta cu ndo est desenganchado suelto el gatillo de la pistola Abre el circuito el ctrico al motor y bloquea la hidrolimpiadora de presi n N Cuando la hidrolimpiadora no est en uso es necesario que dicho interruptor est ATENCI N colocado da en OFF para prevenir posibles accidentes o da os SOBRECARGA DEL MOTOR El motor el ctrico de la hidrolimpiadora posee un di spositivo de protecci n contra la sobrecarga que bloquea autom ticamente el motor en el caso de exceso de corriente o en el caso de recalentamiento El dispositivo se resetea autom ticamente y reactiva las condiciones normales de funcionamiento despu s de un breve per odo PROTECCI N CON INTERRUPTOR DIFERENCIAL AUTOMATICO DE SEGURIDAD ATENCI N la hidrolimpiadora de presi n est tambi n dotada de un interruptor el ctrico principal ON OFF This pressure washer is provided with a ground fault circuit interrupter GFCI built into the plug of the power supply cord This device provides additional protection from the risk of electric shock Should replacement of the plug or cord become necessary use only identical replacement parts that include GFCI protection La hidrolimpiadora est dotada de un i
20. ater Plug 13 Screen Filter 14 Garden Hose Inlet Nipple with Quick Connector not shown See page 8 figure 1 15 Chemical Solution Reservoir 16 Holder for Power Cable LISTA PIEZAS Lanzador con Boquilla Turbo Pistola Tubo de alta presi n Porta manguera alta presi n Interruptor ON OFF Conector manguera alta presi n Entrada agua Lanzador con Boquilla Variable Porta accesorios 10 Tornillo Dep sito del liquido detergente 11 Enchufe el ctrico con Interruptor diferencia autom tico de seguridad 12 Tap n agua 13 Filtro 14 Entrerrosca con conexi n r pida no representado Ver la figura 1 de la p gina 8 15 Dep sito del liquido detergente 16 Portacable alimentaci n OSONAOU BRON POWERWASHER 2 0 SAFETY FEATURES The pressure washer is equipped with a stop device which will sense when the trigger on the gun is released It will open the power circuit to the motor and cause the pressure washer fo stop A WARNING WARNING The pressure washer is also equipped with a main power ON OFF switch located on the unit It should always be moved to the off position when the pressure washer is not being used to prevent possible injury or damage MOTOR OVERLOAD The electric motor in this pressure washer is equipped with an overload protection device which will automatically shut off the motor in the event the motor draws excessive current or overheats The device will automatically reset itself
21. cable de alimentaci n Si fuere necesario cambiar el enchufe o el cable utilicen piezas de repuesto del mismo tipo Cuando el equipo es utilizado hay ie seguir precauciones basilares entre las cuales POWERWASHER 7 10 11 YA 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 27 30 Stay alert watch what you are doing Follow maintenance instructions specified in this manual Check power cords before using Damaged cords can reduce performance of pressure washer or cause a fatal electric shock The narrow pin point stream is very powerful It is not recommended for use on painted surfaces wood surfaces or items attached with an adhesive backing Keep operating area clear of all persons To reduce the risk of injury close supervision is necessary when this product is used near children Always use both hands when operating pressure washer to maintain complete control of the wand Do not touch nozzle or water spray while operating Wear safety goggles while operating Disconnect power plug from the outlet when not in use and prior to the detaching of the high pressure hose Never tie knots or kink the high pressure hose as damage could result Prior to starting the pressure washer in cold weather be sure ice has not formed in any part of the equipment Carefully observe all chemical instructions and warnings before using The pre
22. desde abajo hacia arriba para distribuirla uniformemente y para evi tar los estriados 3 Eliminen el exceso de cera del aparato de baja presi n NOTA SI EL EXCESO DE CERA NO ES EXTRAIDO SE PUEDE OBTENER UN RESULTADO OPACO 4 Efect en el secado para reducir las manchas de agua 4 7 FINALIZACI N DE LA OPERACI N Cuando habr n concluido la utilizaci n del sistema de inyecci n de productos qu micos extraigan la manguera del recipiente hagan funcionar a n a baja presi n y agan pasar agua limpia por el dep sito del liquido detergente hasta que est completamente limpio NOTA La falta de una limpieza a fondo puede provocar una obturaci n en el sistema de inyecci n y ser inutilizable e Detengan el equipo presionando el bot n on off e Desconecten la toma el ctrica e Cierren el anio y depresuricen el equipo presionando el gatillo POWERWASHER WARNING Turn off water supply and squeeze trigger to depressurize the unit Failure to do so al result in personal injury due to discharge of high pressure wafer A CAUTION e Disconnect the high pressure discharge hose and the water inlet hose 5 0 MAINTENANCE 5 1 CONNECTIONS Connections on Pressure Washer hoses gun and spray wand should be cleaned regularly and lubricated to prevent leakage and damage to the o rings 5 2 NOZZLE The high pressure low pressure adjustment of the nozzle should be lubricated regularly Clogging of the nozzle cau
23. ebe estar asegurada con el gatillo de bloqueo No utilicen el equipo cuando est n muy cansados o cuando est n bajo la influencia de alcohol o de drogas Durante el uso NO cubran la hidrolimpiadora de alta presi n con el fin de permitir una ventilaci n adecuada Aprendan c mo bloquear el producto o purgar la presi n r pidamente Adquieran los debidos conocimientos acerca de los diferentes comandos No suban ni se detengan sobre soportes inestables Asuman siempre una posici n firme y segura ATENCI N Riesgo de insuflaci n o de da os No orienten el flujo contra las personas Para la puesta a tierra v anse las siguientes instrucciones CONSERVEN LAS PRESENTES INSTRUCCIONES POWERWASHER GROUNDING INSTRUCTIONS This product must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and ronda in accordance with all local codes and ordinances WARNING mproper connection of the eguipment grounding conductor can result in a risk of electrocution Check with a gualitied electrician or service person if you are in doubt as to whether the outlet is properly grounded Do not modiity the ala A with the product if it will not fit t
24. el chorro NOTA la presi n del chorro sobre la superficie que est n limpiando aumenta en proporci n a acercamiento del lanzador sobre la superficie misma Para aumentar el ngulo de un chorro de ventilador giren hacia la izquierda Para disminuir el ngulo del chorro de la punta de l piz giren hacia la derecha 4 4 CHORRO DE ALTA PRESI N TURBO A ATENCI N ATENCI N No act en sobre la boquilla para modificar la presi n La posici n de la boquilla turbo de alta presi n ha sido proyectada para obtener el mejor resultado de limpieza Tengan siempre el lanzador de chorro a una distancia entre las 6 y las 8 de la superficie que deseen limpiar POWERWASHER TURBO SPRAY CHORRO SPRAY 4 5 USE OF CLEANING CHEMICALS N CAUTION od use cleaning chemicals canon recommended for pressure washers 1 Insert the relevant suction tube 2 beneath the chemical solution reservoir 2 Fill the reservoir 1 with suitable cleaning solution 3 Insert the chemical solution reservoir into the rela tive compartment in the rear part of the machine 4 Secure the chemical solution reservoir with the screw provided 5 Move the adjustable nozzle forward to the low pressure position i sliding collar toward the nozzle The chemical will automatically be mixed with the water and discharged through the nozzle NOTE When the adjustable nozzle is moved to the high pressure
25. en tomas protegidas Utilicen exclusivamente extensiones de 3 conductores que posean enchufes con puesta a tierra de 3 polos y conectores tripolares aptos para el enchufe del equipo Usen exclusivamente extensiones para uso exterior Dichas extensiones est n marcadas por la frase Aptas ara uso exterior si no las utilizan col quenlas en un gar reparado Usen solamente extensiones con una potencia el ctrica superior a la potencia nominal del equipo No utilicen extensiones da adas Antes del uso controlen la extensi n y si est da ada substit yanla No la usen en modo incorrecto y no tiren del cable ara desenchufar Tengan a las extensiones lejos de Te de calor y de ngulos cortantes Antes de desconectar el equipo de o extensi n desconecten siempre esta ltima de la toma POWERWASHER When usin an extension cord observe the specification below Cable Length Wire Gauge Up to 50 ft 14 AWG 50 to 100 ft 12 AWG WARNING To reduce the risk of electrocution keep all connections dry and off the ground Do not touch plug with wet WARNING hand WATER CONNECTION Cuando se utilizan extensiones respeten las siguientes caracter sticas Calibres cable 14 AWG 12 AWG Longitud cable Hasta 50 pies De 50 a 100 pies IMPORTANTE Para reducir la posibilidad de que el cable sea fulminado mantengan la extensi n seca y tuera de tierra No toquen ATENCI N enchufe con las manos mojadas CONEXI N DE
26. et Thaw out unit completely including hose gun and wand Clean screen See section 5 4 Let pressure washer run with gun open and wand removed until steady stream of water is released Set to maximum position See Section 4 2 Call Powerwasher FAIP Customer Service Department Call Customer Service Department Push firmly into machine Replace tubing Switch nozzle to low pressure Clean nozzle See Section 5 2 Clean strainer Dissolve by running warm water through the injection tube Trigger will not move Gun safety lock engaged Release safety lock 7 0 LOCALIZACION DE LAS AVERIAS PROBLEMAS CAUSAS PROBABLES SOLUCION El motor no arranca o se detiene El GCFI salta o no se resetea Apagar el aie Presionar la tecla durante el funcionamiento Reset del GFCI despu s de haberlo El interruptor del circuito se desconecta o los fusibles estan quemados en la caja de fusibles Enchufe flojo o no conectado El interruptor de circuito de la hidrolimpiadora ha saltado el conectado al alimentador el ctrico Desconectar todas las dem s cargas sobre de circuito o cambiar los fusibles Reconectar el enchufe Dejar enfriar y descansar el equipo mismo circuito y resetear el interruptor 19 POWERWASHER PROBLEMAS CAUSAS PROBABLES SOLUCION L interruptor de circuito salta o est n quemados los fusibles en la caja de fusibles El GFCI se desconecta continuame
27. he outlet installed by a qualified electrician Do not use any type ao adaptor with this product WARNING ISTRUCCIONES PARA LA PUESTA A TIERRA Este equipo debe poseer la puesta a tierra En caso de funcionamiento defectuoso o de averia la puesta a tierra suministra un recorrido de resistencia minima para la corriente el ctrica con el fin de reducir el riesgo de sacudidas El equipo est dotado de un cable que incluye un conductor y enchufe de tierra El enchufe debe ser introducido en una toma apropiada instalada en modo id neo y con puesta a tierra seg n lo establecido por las leyes y disposiciones locales A ATENCI N IMPORTANTE Una conexi n impropia entre el equipo y el conductor de tierra puede provocar sacudidas el ctricas Si tienen dudas sobre la id nea puesta a tierra de la toma consulten con un electricista o con un encargado de la manutenci n No modifiquen el enchufe suministrado con el equipo en caso con frario adapten la toma instalada con la ayuda de un electricista cualificado No utilicen adaptadores para este equipo POWERWASHER DISE O PIEZAS PARTS DRAWING PARTS LIST Wand with Turbo Nozzle Head Spray Gun High Pressure Hose Holder For High Pressure Hose ON OFF Switch High Pressure Hose Connector Threaded Water Inlet Wand with Variable Nozzle Head Holder for Accessories 10 Screw Chemical Solution Reservoir 11 Electrical GFCI Plug OONAOU RON 12 W
28. his cord should only be connected to an electrical outlet installed in accordance with local safety regulations NOTE The power supply must be 120v 60hz and a minimum 15 amp circuit WARNING Test GFC before each use DO NOT use pressure washer if test below WARNING fails GFCI Test Procedures 1 Plug GFCI into power receptacle 2 Press reset button 3 Press test button 4 Press reset button again for use NOTE The GFC must be reset each time the pressure washer is connected to an electrical outlet Reset by simply pushing the reset bution on the GFC power plug A WARNING A Connect only to properly grounded outlet Do not remove grounding pin B Inspect cord before using Do not use if cord is damaged C Keep all connections dry and off the ground Do not touch plug with wet hands E The pressure washer is provided with a ground fault circuit interrupter built into the power plug If replacement of the plug or cord is needed use only identical replacement parts Contact Customer Service for proper replacement parts Extension cords are not recommended unless they are plugged into a receptacle protected by a ground fault circuit interrupter Any extension a used should be 14 AWG and no longer than 50 feet to prevent excessive voltage loss Use only extension cords intended for outdoor use These extension cords are identified by a marking Acceptable for use with outdoor appliances store indoors
29. is allowed to dry on the surface Wash CAUTION and rinse a small section at a time Avoid working on hot surfaces or in direct sunlight CAUTION Damage may occur to Rinse with clean water under high pressure On a vertical surface first rinse from the bottom up then rinse from the top down Hold nozzle 6 to 8 inches from the work surface at a 45 angle using the flat spray as a peeling tool rather than a scrub brush NOTE nsure that the chemical injection system is completely clean prior to switching from one chemical to another APPLICATION OF LIQUID VEHICLE WAX 1 Immediately after cleaning apply Pressure Washer Liquid Vehicle Wax using low pressure Pour wax into chemical solution reservoir Apply the wax sparingly in an even layer Apply to wet surfaces from the bottom up for even distribution and to avoid streaking Rinse off the surplus wax NOTE IF SURPLUS WAX IS NOT REMOVED A HAZY FINISH MAY RESULT Wipe dry to reduce water spotting 4 7 END OF OPERATION When you have completed use of the chemical injection system remove tube from container continue to run in low pressure position and flush clean water through the hem eal tank until it is thoroughly cleaned NOTE Failure to clean properly will cause the injection system to become clogged and inoperable Stop the unit by pressing to ON OFF button Disconnect electrical plug Turn off water and depressurize unit by squeezing trigger APLICACION
30. l y no pueda ser substituida La presente garant a les confiere derechos espec ficos y Uds pueden tener tambi n otros derechos que var an de un Estado a otro POWERWASHER 2455 PACES FERRY RD N W ATLANTA GEORGIA 30339 4024 1 888 550 1606 Sitio Internet www hdpowerwasher com Registro de garantia mediante Internet d e 12 2001 cod PLDC83350 REV 1
31. llow air to escape from the hose squeeze trigger on the gun until there is a steady stream of water Remove any dirt or foreign matter from the gun outlet and the male connector of the wand Insert the requested wand into the gun s quick connect ii aa by pushing firmly and twisting wand Y4 of a turn to lock into place NOTE Moke sure wand is locked 4 Con el fin de permitir la salida de aire de la manguera aprieten el gatillo de la pistola hasta que salga un flujo regular por la boquilla 5 Extraigan la suciedad o los materiales extra os de la salida de la pistola y del conector blando del lanzador 6 Introduzcan e anda or en la uni n r pida empujando en rgicamente y luego girando el lanzador de 1 4 de vuelta para bloquearlo en su sede NOTA Seg rense de que el bloqueo de seguridad est cerrado POWERWASHER WARNING if the wand is not securely locked into place it could be ejected under high pressure when operating the gun possibly causing injury or damage A WARNING 7 Squeeze trigger on the spray gun 8 Press the on off button to start pressure washer IMPORTANTE Si el lanzador no est bien bloqueado en su sede cuando se N utiliza la pistola podria ser expulsada ATENCI N 2 4 d0 a la alta presi n provocando a os y perjuicios 7 Presionen el gatillo en la pistola de chorro 8 Presionen la tecla ON OFF para poner en marcha la hidrolimpiadora ON
32. n para garantizar la refrigeraci n del motor con aire limpio durante el uso A ATENCI N IMPORTANTE viten que el agua penetre en los respiraderos de la hidrolimpiadora para que el riesgo de da ar la m quina sea m nimo y para reducir el peligro de sacudida el ctrica al operador POWERWASHER 6 0 MOVING AND STORAGE INSTRUCTIONS CAUTION Always store your pressure washer in a location where the temperatu N re will not fall below 32 F The pump in this machine is susceptible to permanent CAUTION damage if frozen FREEZE DAMAGE IS NOT COVERED BY THE WARRANTY If you must store your pressure washer in a location where the temperature is below 32 F you can minimize the chance of damage to your machine by utilizing the following procedure 1 Stop the pressure washer and detach supply hose and high pressure hose Squeeze the trigger of the discharge gun to drain all water from the wand and hose Restart the pressure washer and let it run briefly about 5 seconds until water no longer discharges trom the high pressure outlet 6 1 AFTER EXTENDED STORAGE Scale deposits may form in the pump when it is not used for some time This causes the motor to run stiff or it may not start up at all Remove scale deposits from the piping Connect machine to water supply and rinse thoroughly with water Do not plug unit into electrical outlet E ase electrical overloading turn the motor shaft by and 6
33. nte Hay p rdidas de agua y aceite desde el fondo de la bomba Sobrecarga circuito Extensi n demasiado larga o dimensi n del cable demasiado peque a Boquilla parcialmente bloqueada Presi n excesiva Voltaje equivocado Cortocircuito interior Una peque a p rdida es normal Controlen que el circuito est regulado en 15 o m s amp Desconecten todas las cargas del circuito Usen una extensi n id nea como aconsejado en el Manual del Operador Limpien la boquilla como indicado en la secci n 5 2 Reducir la presi n con la manopla de regulaci n V ase secci n 3 3 Llamen a la Oficina de Asistencia Clientes Si la p rdida es excesiva hay que contactar la Oficina de Asistencia Clientes de la Powerwasher FAIP Cuando la pistola est cerrada aumenta la presi n El motor gira pero la bomba no suministra fe maxima presi n o tiene una presi n irregular No se obtiene la introducci n de productos qu micos La v lvula de bypass no funciona correctamente Grifo cerrado El equipo ha sido almacenado a temperaturas muy fr as La pantalla de introducci n agua est obturada Pliegues de la manguera de jardin Aire en la bomba La manopla de regulaci n de la presi n no se coloca en la posici n m xima V lvulas de aspiraci n o de descarga obturadas o fuera de uso La v lvula by pass no funciona correctamente La manguera de inyecci n no est conectada correctamente a la hidrolim
34. nterruptor diferencial autom tico de seguridad GFCI montado en el enchufe del cable de alimentaci n el ctrica Dicho dispositivo suministra una protecci n adicional contra el riesgo de sacudidas Si fuere necesario substituir el enchufe o el cable utilicen exclusivamente repuestos similares provistos de protecci n GFCI EXTENSION CORDS WARNING extension cords are nof recommended unless they are plugged into a ground faulf circuit interrupter jae in WARNING circuit boxes or protected receptacles Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole cord connectors that accept the plug Fon the product Use only extension cords that are intended for outdoor use These extension cords are identified by a marking Acceptable for use with outdoor appliances store indoors while not in use Use only extension cords having an electrical rating higher than the rating of the product Do not use damaged extension cords Examine extension cord before using and replace if damaged Do not abuse extension cord and do not yank on any cord to disconnect Keep cord away from heat and sharp edges Always disconnect the extension cord from the receptacle ae disconnecting the product from the extension cord EXTENSIONES ATENCI N No se aconseja el uso de extensiones s stas no est n conectadas a un interruptor diferencial autom tico de ATENCI N seguridad puesto en cajas del circuito o
35. piadora La manguera est arruinada o rota Regulaci n equivocada de la boquilla La boquilla est bloqueada El filtro de la manguera est tapado Los productos qu micos se han secado en el inyector Llamen a la Oficina de Asistencia Clientes Abran el grifo Descongelar completamente el Srl incluidos las mangueras la pistola y el lanzador Limpien la pantalla V ase secci n 5 4 Enderecen la manguera Dejen en funcionamiento la id ak con la pistola abierta y el lanzador desplazado hasta que se obtenga un flujo de agua regular Calibrar en la Do ren maxima V ase secci n 4 Consulten con la Oficina de Asistencia Clientes Dirigirse a la Oficina de Asistencia Clientes Empujen con fuerza en el equipo Cambiar Desconecten la boquilla para bajar la presi n Limpiar V ase secci n 5 2 Limpiar el filtro Disolver haciendo correr agua corriente en la manguera de inyecci n El gatillo no se mueve Est conectado el bloqueo de seguridad de la pistola eae el bloqueo de seguridad 20 POWERWASHER 8 0 REPLACEMENT PARTS AND 8 0 PIEZAS DE REPUESTO Y ACCESSORIES ACCESORIOS THE FOLLOWING LIST OF ACCESSORIES AND ESTAN A DISPOSICION LOS ACCESORIOS Y LAS REPLACEMENT PARTS ARE AVAILABLE PIEZAS DE REPUESTO PRESENTADOS EN LA SIGUIENTE LISTA PLEASE CONTACT CUSTOMER SERVICE FOR MORE PARA MAYORES INFORMACIONES CONTACTEN El INFORMATIO
36. position chemical will not be discharged 4 5 UTILISATION DE PRODUITS CHIMIQUES ATTENTION utilisez seulement des produits chimiques sp cifiquementconcus ATTENTION Pour les pulv risateurs puissants 1 Glissez le tube d aspiration 2 sur le raccord situ sous le r servoir 2 Remplissez le r servoir 1 d un d tergent convenable 3 Emboitez le r servoir dans le compartiment appropri situ l arri re de Vappareil 4 Fixez le r servoir en place l aide de la vis fournie 5 Muevan la boquilla regulable hacia la posici n de baja presi n haciendo desplazar la abrazadera brida hacia la boquilla El producto qu mico ser mezclado as ik con el agua y descargado a trav s de la boquilla REMARQUE lorsque la buse r glable produit un jet haute pression le produit chimique n est pas aspir du r servoir Ww WY DR 4 6 CLEANING TECHNIQUES When cleaning with the pressure washer some cleaning tasks can be solved with water alone but for most tasks it is advantageous to use a detergent A detergent ensures a quick soaking of the dirt allowing the high pressure water to penetrate and remove the dirt more effectively The low pressure position provides a gentle application of chemicals This position is also recommended to rinse a surface after wax application or for other applications which require the low pressure of a garden hose Low pressure is the eq
37. ration A CAUTION WARNING prevent water from penetrating the vents of the pressure washer to minimize the risk of damage to the machine and to reduce the risk of shock to the operator 5 3 LUBRICACI N La hidrolimpiadora ha sido creada con un sistema de lubricaci n permanente No son necesarios controles convencionales ni la substituci n de aceites NOTA EN El CASO DE P RDIDA DE ACEITE CONTACTEN AL SERVICIO CLIENTES DE LA SOCIEDAD HD POWERWASHER SECCION REPARACIONES UNA PEQUENA PERDIDA DE ACEITE ES NORMAL 5 4 PANTALLA AGUA La hidrolimpiadora est dotada de una pantalla de introducci n de agua para proteger la bomba A ATENCI N Si no se mantiene limpia la pantalla el flujo del agua hacia la hidrolimpiadora se ve limitado y la bom ATENCION ba puede da arse e Para limpiar la pantalla m s interna del agua extraigan la uni n r pida y la pantalla de pl stico de introducci n de la bomba ver la p g 6 pos 13 e La pantalla de retorno flujo debe estar limpia e Substituyan inmediatamente la pantalla y la uni n r pida para evitar que entre material extra o en la bomba ATENCI N No da en la pantalla cuando la extraen y la limpian Cualquier part cula N extra a que pudiera entrar en las bombas ATENCI N podr ada arla 5 5 SISTEMA DE REFRIGERACI N Los respiraderos de aire colocados en la hidrolimpiadora y a su alrededor deben ser mantenidos limpios de cualquier obstrucci
38. ses he pump pressure to be ok and cleaning is immediately required 1 Separate the nozzle from the wand 2 Clear the nozzle ATENCI N Cierren la alimentaci n del ik y presionen el gatillo para epresurizar el equipo la falta de depresurizaci n puede provocar da os a ATENCI N as personas debido a la descarga del agua de alta presi n e Desconecten la manguera de descarga de la alta presi n y la manguera de introducci n del agua 5 0 MANUTENCI N 5 1 CONEXIONES Las conexiones a mangueras la pistola y el lanzador de chorro de la rele ee ed Ee ser limpiados regularmente y lubricados para prevenir las p rdidas y la rotura de los o rings 5 2 BOQUILLA El dispositivo de regulaci n de la alta baja presi n de la boquilla debe ser lubricado con regularidad La obturaci n de la boquilla provoca el aumento de la presi n de la bomba y con toda probabilidad la distorsi n de la forma del chorro Se requiere una limpieza inmediata 1 Separar la boquilla del lanzador 2 Limpien la boquilla Flush the nozzle backwards with water 3 4 Reconnect the nozzle to the wand NOTE Complitely screw the nozzles on the wand up to the complete lock see picture Restart the pressure washer and depress the trigger on the spray gun If the pressure is still too high repeat above items 1 4 15 3 Laven abundantemente con agua hacia la parte trasera de la boquilla 4 Conectar nuevamente
39. si no son Ea pueden PELIGRO provocar da os personales o la muerte Este s mbolo identifica las instrucciones de procedimientos espec ficos que si no son observadas rigurosamente pueden IMPORTANTE Provocar da os o hasta la destrucci n el equipo mismo Esta unidad ha sido dise ada para aplicaciones espec ficas No hay que aportar modificaciones y o utilizarla para aplicaciones diferentes de aquellas para las cuales ha sido pensada A PELIGRO 1 Lean atentamente el presente manual para conocer su equipo Tomen en debida consideraci n sus aplicaciones limitaciones y los potenciales riesgos espec ficos 2 Son necesarias salidas con un tercer enchufe de masa No utilicen sin ese enchufe 3 No toquen el enchufe o la toma con las manos mojadas 4 Eviten encendidos accidentales Coloquen el interruptor en OFF antes de conectar o desconectar el cable el ctrico a una toma 5 No dirijan nunca el chorro del agua sobre instalaciones el ctricas o sobre a misma hidrolimpiadora de alta presi n con el fin de evi tar sacudidas el ctricas 6 No utilicen el cable para mover la hidrolimpiadora de alta presi n No tirar del cable para desconectar el equipo de la toma 7 Con el fin de evitar da os el cable no debe ser aplastado no debe ser colocado cerca de objetos cortantes ni de fuentes de calor 8 Este art culo es suministrado con un interruptor diferencial autom tico de seguridad insertado en el enchufe del
40. ssure washer should not be used in areas where gas vapors may be present An electric spark could cause an explosion or fire To minimize the amount of water getting into the pressure washer the unit should be placed as far as possible from the cleaning site during operation To prevent accidental discharge the spray gun should be secured by locking trigger when not in use Do not operate this product when fatigued or under the influence of alcohol or drugs To allow free air circulation the pressure washer should NOT be covered during operation Know how to stop the product and bleed pressure quickly Be thoroughly familiar with the controls Do not over reach or stand on unstable support Keep good footing and balance at all times WARNING Risk of injection or injury Do not direct discharge stream at persons See below for grounding instructions SAVE THESE INSTRUCTIONS 7 10 11 13 14 17 18 20 21 22 23 24 25 26 27 28 29 30 Est n atentos y miren bien lo que se estan haciendo Para la manutenci n sigan las instrucciones presentadas en el presente manual Antes del uso controlen los cables el ctricos Los cables da ados no s lo reducen las prestaciones de la hidrolimpiadora de alta presi n sino que pueden provocar sacudidas el ctricas El flujo de la punta del del alfiler estrecho es muy potente No se aconseja para el uso sobre s
41. t from electrical outlet e Desconecten el enchufe del conector principal Remove cover Fig A Extraigan el revestimiento de paneles Fig A Insert a suitable dari fh socket wrench size 4 Introduzcan una llave de casquillo hexagonal mm through the middle Ee in the fan cover apropiada 4 mm a trav s de la apertura central and into the hexagon socket in the motor shaft en la tapa del ventilador y en el alojamiento e Turn the motor shaft clockwise by hand several times hexagonal en el eje motor l l Fig B O Giren aaa veces a mano el eje motor en sentido Remove hexagon socket wrench retr grado Fig B l kes e Saquen la llave de casquillo hexagonal e Plug unit into electrical outlet e Vuelvan a montar el revestimiento de paneles e Swichonmachine wih sproy gun epa e Introduzcan el enchufe del conector principal en la caja de la toma de corriente e Enciendan el aparato con la pistola de chorro abierta 7 0 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTION Motor will not start or stops while GFCI tripped or not reset Turn off unit Press GFCI reset button operating irmly after it has been connected to the electrical supply Circuit breaker tripped or fuse Disconnect all other loads on the blown in circuit fuse box same circuit and reset circuit breaker or replace fuse Loose or disconnected plug Reconnect plug Tripped pressure washer circuit Allow to cool and restart unit
42. uctos reparados Los da os causados por un mal uso accidente reparaci n impropia o falta de manutenci n El empleo de productos qu micos inadecuados y el no respeto de las instrucciones del manual para el uso Las ventas fuera de los Estados Unidos o de Canad Cualquier otro gasto que comprenda da os indirectos da os accidentales o gastos accidentales incluidos los da os a la propiedad Algunos Estados no permiten la exclusi n o la limitaci n de los da os accidentales o indirectos por lo tanto dicha limitaci n o exclusi n podr a no ser referida a Uds La presente garant a no cubre los da os resultantes de la falta de observaci n de una de las siguientes condiciones 1 2 La presi n del agua en entrada debe estar entre los 20 y los 100 p s i La temperatura del agua en entrada no debe su perar los 90 F El equipo no debe ser almacenado en zonas donde la temperatura puede llegar por debajo de los 32 F 3 GARANT AS IMPL CITAS cualquier garant a impl cita incluidas las garant as impl citas de comerciabilidad e idoneidad con un fin particular est limitada en la duraci n a un 1 a o a partir de la fecha de la compra al por menor Algunos Estados no admiten limitaciones sobre la duraci n de la garant a impl cita por lo tanto dicha limitaci n podr a no referirse a Uds HOW TO OBTAIN WARRANTY attach to the product your name address description of the problem phone number and proof
43. uivalent of a garden hose set at the lowest output to properly apply chemical FOR CHEMICAL APPLICATION SLIDE COLLAR ACCORDING TO SECTION 4 2 4 6 T CNICAS DE LIMPIEZA Cuando se procede a la limpieza con la hidrolimpiadora se pueden efectuar diferentes operaciones s lo con al aac en muchos casos sin embargo es conveniente utilizar tambi n un detergen te El uso de un detergente asegura un tratamiento inmediato de la pieced permitiendo al agua con alta presi n penetrar y eliminar eficazmente la suciedad La posici n de baja presi n suministra una aplicaci n delicada del producto qu mico Recomendamos esta posici n tambi n para enjuagar una superficie despu s de la aplicaci n de cera y de otras aplicaciones que requieran la baja presi n de una manguera de jard n La baja presi n equivale a una manguera de jard n ad en el rendimiento m s bajo para aplicar en modo correcto el producto qu mico PARA APLICACIONES CON PRODUCTOS QU MICOS HAGAN DESPLAZAR LA ABRAZADERA BRIDA COMO ESPECIFICADO EN LA SECCION 4 2 POWERWASHER APPLICATION OF SOAP DEGREASER 1 Apply the solution to a DRY work surface NOTE WETTING THE SURFACE FIRST IS NOT RECOMMENDED AS IT DILUTES THE DETERGENT AND REDUCES ITS CLEANING ABILITY On a vertical surface apply horizontally from side to side starting from the borom to avoid streaking Allow chemical to remain on the surface for a short time before rinsing painted surface if chemical
44. uperficies pintadas sobre superficies de madera o sobre objetos con revestimiento adhesivo Alejen a las personas del rea de trabajo Para reducir los riesgos de da os es absolutamente necesario efectuar un control atento cuando el producto es utilizado cerca de los ni os Usen siempre ambas manos cuando se utiliza la hidrolimpiadora de alta presi n con el fin de man tener un completo control del lanzador de la manguera No toquen el lanzador o el chorro de agua cuando est en funcionamiento Durante el uso utilicen gafas de protecci n Desconecten el enchufe el ctrico de la toma cuando no est en uso e igualmente antes de extraer la manguera de alta presi n Hay que utilizar exclusivamente las mangueras y los lanzadores de la hidrolimpiadora de alta presi n En las estaciones fr as antes de poner en funcionamiento la hidrolimpiadora controlen que no se haya formado hielo en la misma Observen escrupulosamente todas las instrucciones qu micas y las advertencias antes del uso No hay que utilizar la hidrolimpiadora en reas donde hayan vapores gaseosos Una eventual chispa el ctrica podr a provocar una explosi n o un incendio Para reducir al m ximo la cantidad de agua que podr a entrar en la hidrolimpiadora de alta presi n durante el uso colocarla lo m s lejos posible de la zona que debe ser limpiada Con el fin de evitar escapes accidentales cuando no est en uso la pistola de chorro d