Home

Installation Instructions Electric Dryer 01

image

Contents

1. DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET AWARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVES REMOVE SCREW REMOVE DESIRED KNOCKOUT ONE ONLY Detach and remove the bottom right or left side knockout as desired Remove the screw inside the dryer exhaust duct and save Pull the duct out of the dryer Cut the duct as shown and keep portion A TAB LOCATION BEND TAB UP 45 Through the rear opening locate the tab in the middle of the appliance base Lift the tab to about 45 using a flat blade screwdriver ADDING NEW DUCT FIXING HOLE PORTION A RIGHT OR LEFT SIDE EXHAUST Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base Installation Instructions ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET ePreassemble 4 elbow with 4 duct Wrap duct tape around joint e Insert duct assembly elbow first through the side opening and connect the elbow to the dryer internal duct ACAUTION Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct EXHAUST CAN BE AD
2. cables a una secadora el ctrica Conecte de acuerdo con la ilustraci n del bloque terminal que corresponde a su secadora Vuelva a 4 conductores colocar el de cobre 10 Cable Cable tornillo verde AWG m nimo vivo Tornillo verde de conexi n kit de cable a tierra aqu de suministro de energ a de 120 240V 30A marcado para su uso con secadoras y Tornillo Quite la cinta de conexi n 2 a tierra y desc rtela Neutral Conserve el tornillo provisto con terminales de bucle cerrado o hembra Alivio de de alivio con extremos tensi n de 3 4 de tensi n hacia arriba reconocido por UL no provistos verde de l conexi n VIVO a tierra Tornillo Vuelva a 4 conductores colocar el de cobre 10 Cable tornillo verde Cable AWG m nimo Tornillo vivo deconexi n verde o kit de cable de suministro a tierra aqu de energ a de Y 120 240V 30A AR marcado para Tornillo Quite la cinta__356 de conexi n a tierra y desc rtela Neutral Conserve blanco el tornillo verde de su uso con secadoras y provisto con terminales de bucle cerrado o hembra conexi n Alivio de Soporte con extremos atiera Cable tensi n de 3 4 de alivio hacia arriba vivo reconocido por UL de tensi n no provistos 1 Desactive el interruptor de circuitos 30 amperios o quite el fusible del circuito de la secadora de la caja el ctr
3. conductos deben ser herm ticas al aire y a la humedad mediante la superposici n de juntas con cinta aislante Los tramos horizontales deben tener una inclinaci n hacia el exterior de 1 4 por pie AISLACI N Los conductos instalados a trav s de una rea sin calefacci n o ubicados cerca de un acondicionador de aire deben aislarse para reducir la condensaci n y la acumulaci n de pelusas CONEXI N A LA SALIDA A ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO O DE LESIONES PERSONALES e Esta secadora de ropa debe tener una salida al exterior eUtilice s lo un conducto de metal r gido de 4 para el conducto de salida dom stico e Use s lo un conducto de metal r gido de 4 o de metal flexible semi r gido o de tipo papel de aluminio aprobado por UL para conectar la secadora al conducto de salida dom stico Debe instalarse de acuerdo con las instrucciones incluidas en C mo conectar la secadora a la ventilaci n dom stica de las p ginas 4 5 de este manual e No instale la boca de salida dentro de una chimenea pared cielorraso ventilaci n de gas espacio entre pisos tico bajo un piso con cerramiento o en cualquier otro espacio oculto de un edificio La acumulaci n de pelusas podr a provocar un riesgo potencial de incendio e Nunca instale la boca de salida dentro de un conducto com n con el sistema de salida de la cocina La combinaci n de grasa y pelusas podr a provocar un riesgo potencial de
4. exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do not obstruct incoming or exhausted air eProvide an access for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once a year There are multiple installation options Select the most appropriate method for your installation situation STANDARD REAR EXHAUST Vented at floor level For straight line installation connect the dryer exhaust to the external exhaust hood using duct tape or clamp EXTERNAL DUCT OPENING DUCT TAPE OR DUCT CLAMP ra 4 METAL DUCT CUT TO PROPER LENGTH DUCT TAPE OR DUCT CLAMP NOTE WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING HOWEVER IF FLEXIBLE DUCTING IS USED IT MUST BE UL LISTED METAL NOT PLASTIC STANDARD REAR EXHAUST Vented above floor level ELBOW HIGHLY RECOMMENDED RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE ELBOW HIGHLY O i RECOMMENDED AZ AAZ AS NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT e For best drying performance a rigid metal transition duct is recommended e Rigid metal transition ducts reduce the risk of crushi
5. semi rigid ducting cannot be used AND where a 4 DRYER diameter can be maintained throughout the entire length Stand the dryer upright near the final location and adjust of the transition duct the 4 leveling legs at the corners to ensure that the dryer e In Canada and the United States only the flexible metal is level from side to side and front to rear foil type ducts that comply with the Outline for Clothes LEVEL ei Dryer Transition Duct Subject 2158A shall be used FRONT TO BACK SIDE TO SIDE e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m e Avoid resting the duct on sharp objects LY EEE E y We ELBOW HIGHLY RECOMMENDED _ 4 LEVELING LEGS ELBOWS HIGHLY RECOMMENDED 6 ALCOVE OR CLOSET INSTALLATION elf your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back eThe dryer MUST be vented to the outdoors See the EXHAUST INFORMATION sections 3 amp 4 ES e Minimum clearance between dryer cabinet and adjacent ON FLEXIBLE walls or other surfaces is geen O in either side WIR 3 in front DO NOT USE 3 in rear shane e Minimum vertical space from floor to overhead cabinets LENGTH ceiling etc is 52 in f eCloset doors must be louvered or otherwise ventilated and must contai
6. wire single phase 120 240V or 120 208V 60Hz 30 amp circuit is required GROUNDING INSTRUCTIONS This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal on the appliance CONNECTING DRYER USING 4 WIRE CONNECTION MUST BE USED FOR MOBILE HOME INSTALLATION NOTE Since January 1 1996 the National Electric code requires that the new constructions utilize a 4 wire connection to an electric dryer Wire according to the terminal block illustration that matches your dryer Relocatre green ground Screw ve screw here 4 10 AWG minimum Screw A copper Remove C conductors ground strap 5 or 120 240V and discard gt s a 30A power Keep green AUG supply cord kit ground Neutra Td marked for use Screw white S fv with dryers mene FS train And provided ot Wire i with closed Relief Screw loop or spade terminals with upturned ends not supplied Hot Wire 3 4 UL Recognized Bracket Strain Relief Relocatre green ground Green Screw Hot Wire screw here Wire 4 10 AWG minimum Screw copper Remove a conductors ground trop CE or 120 240V and discard Y Sl TE rt Keep green AL S 30A power supply cord kit marked for use with dryers and provided with closed loop or spade terminals wi
7. ALIDA TRASERA EST NDAR Ventilaci n sobre el nivel del suelo SE RECOMIENDA EL USO DE CODOS CONFIGURA RECOMEN PARA MI LAS OBSTRU DE LA SAL SE RECOMIENDA EL USO DE CODOS Instrucciones de instalaci n NOTA LOS CODOS EVITAN QUE LOS CONDUCTOS SE DOBLEN O CAIGAN C MO CONECTAR LA SECADORA A LA VENTILACION DOMESTICA CONDUCTO DE TRANSICI N DE METAL R GIDO ePara un mejor desempe o de secado se recomienda un conducto de transici n de metal r gido e Los conductos de transici n de metal r gidos reducen el riesgo de aplastamientos y torceduras CONDUCTO DE TRANSICI N DE SEMI R GIDO APROBADO POR UL e Si no puede utilizarse un conducto de metal r gido entonces puede usarse un conducto de metal flexible semi r gido aprobado por UL Kit WX08X1007 7 e Nunca instale conductos de metal flexibles en paredes cielorrasos pisos u otros espacios cerrados eLa longitud total del conducto de metal flexible no deber superar los 8 pies 2 4 m ePara muchas aplicaciones se recomienda enf ticamente la instalaci n de codos en la secadora y en la pared ver ilustraciones de abajo Los codos permiten que la secadora se ubique cerca de la pared sin torcer o aplastar el conducto de transici n lo que potencia al m ximo el desempe o de secado e No coloque el conducto sobre objetos afilados CONDUCTO DE TRANSICI N DE METAL FLEXIBLE SEMI R GIDO APROBADO POR UL e En ins
8. AS os LA SECADORA ECESARIO CAPACIDAD UL DE KIT WX08X10077 INCLUYE 2 CODOS 220 240V 30A ALMO DETENSI N CON 3 O 4 PUNTAS DE 34 RECONOCIDO ANTES DE COMPRAR EL D DN GUANTES POR UL CORD N IDENTIFIQUE CINTA ADHESIVA EL TIPO DE ENCHUFE DE I N DE METAL ACUERDO CON EL FLEXIBLE TIPO PAPEL DE ALU APROBADO POR UL S FUERA NECESARIO 4 PLACA DE CUBIERTA ODE M RECEPTACULO INIO DE 4 DE DIA DE LA CASA Espacio m nimo diferente a instalaci n en nichos o closets Los espacios libres m nimos respecto de superficies combustibles y de aberturas de aire son Espacio de 0 pulg a ambos lados 1 pulg en el frente y 3 pulg en la parte trasera Debe tenerse en cuenta un espacio libre adecuado para un funcionamiento y reparaci n correctos Impreso en M xico 234D2008P001 31 16714 03 13 GE Instrucciones de instalaci n PREPARACI N PARA LA INSTALACI N DE UNA SECADORA NUEVA CONSEJO Instale su secadora antes de instalar la lavadora Esto permitir un mejor acceso cuando instale la salida de la secadora COMO QUITAR PELUSA DE LA ABERTURA DE LA SALIDA DE LA PARED e Quite y descarte el conducto de transici n existente de pl stico o de papel de aluminio y coloque un conducto de transici n aprobado por UL ABERTURA DE CONDUCTO INTERNA VERIFIQUE QUE EL REGULADOR DETIRO DE LA CAMPANA DE SALIDA SE ABRA Y CIERRE LIBREMENTE NCLINE LA SECADORA DE COSTADO Y QUITE LAS ALMO
9. DED TO LEFT OR RIGHT SIDE e Apply duct tape as shown on the joint between the dryer internal duct and the elbow wa CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET e Insert the elbow through the rear opening and connect it to the dryer internal duct e Apply duct tape on the joint between the dryer internal duct and elbow as shown above UM CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET SIDES AND BOTTOM EXHAUST PLATE IKITWE1M454 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in final location AWARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE Kit WE1M454 REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY IMPORTANT PRODUCT NOTIFICATIONS Please go to www GEAppliances com or mail in your product registration card For questions on installation call 800 626 2000 US or 800 561 3344 Canada Instrucciones de instalaci n Preguntas sobre la insta Secadora El ctrica 01 laci n Llame al 1 800 GECARES EE UU o visite nuestro sitio Web en www GEAppliances com EE UU ANTES DE COMENZAR A ADVERTENCIA RIESGO DE INCENDIO Lea estas instruccion
10. HADILLAS DE ESPUMA PARA ENV O OM NDOLAS DE LOS COSTADOS Y ARRANC NDOLAS DE LAS PATAS DE LA SECADORA ASEG RESE DE QUITAR ODAS LAS PIEZAS DE ESPUMA UBICADAS ALREDEDOR DE LAS PATAS INFORMACI N SOBRE CONEXIONES ELECTRICAS A ADVERTENCIA para REDUCIR EL RIESGO DE INCENDIO DESCARGA ELECTRICA Y LESIONES PERSONALES 2 e NO UTILICE UN CABLE DE EXTENSION O UN ENCHUFE ADAPTADOR CON ESTE APARATO La secadora debe contar con una conexi n el ctrica a tierra en cumplimiento con los c digos y ordenanzas locales o si stos no existieran de acuerdo con el CODIGO EL CTRICO NACIONAL ANSI NFPA N 70 REQUISITOS ELECTRICOS Esta secadora debe conectarse a un circuito derivado individual con la protecci n de los fusibles de tiempo retardado o interruptores de circuito requeridos Se requiere un circuito de tres o cuatro cables fase Unica 120 240V 6 120 208V 60Hz y 30 amperios INSTRUCCIONES DE CONEXION A TIERRA Esta secadora debe conectarse a un sistema de cableado permanente con conexi n a tierra o debe utilizarse un conductor de conexi n a tierra del equipamiento con los conductores de circuito y conectarse a la terminal de conexi n a tierra del aparato C MO CONECTAR LA SECADORA USANDO UNA CONEXION DE 4 CABLES DEBE UTILIZARSE EN INSTALACIONES DE CASAS MOVILES NOTA Desde el 1 de enero de 1996 el C digo El ctrico Nacional exige que las nuevas construcciones utilicen una conexi n de 4
11. ITIDO LOSALIDA DE LA SECADORA HACIA LA DERECHA IZQUIERDA O PARTE INFERIOR DEL GABINETE ADVERTENCIA ANTES DE EFECTUAR ESTAINSTALACI N DESALIDA ASEG RESE DE DESCONECTAR LA SECADORA DEL SUMINISTRO EL CTRICO PROTEJA SUS MANOS Y BRAZOS DE LOS LADOS AFILADOS CUANDO TRABAJE DENTRO DEL GABINETE ASEG RESE DE USAR GUANTES QUITE EL TORNILLO DESEADO S LO UNO Despegue y quite el recorte inferior derecho o izquierdo seg n corresponda Quite el tornillo ubicado dentro UBICACI N DE LA LENGUETA ORIFICIO DE MONTAJE 13 1 2 13 1 4 para ventilaci n inferior Corte el conducto como puede verse y conserve la porci n A GIRE LA LENGUETA HASTA 45 A trav s de la abertura trasera ubique la lengueta en el medio de la base del aparato Levante la lengUeta hasta alrededor de 45 utilizando un destornillador de lados planos Instrucciones de instalaci n C MO AGREGAR CONDUCTOS NUEVOS ve ii ORIFICIO DE MONTAJE SALIDA LATERAL POR DERECHA O IZQUIERDA Vuelva a conectar la porci n cortada A del conducto a la carcasa del ventilador Aseg rese de que el conducto m s corto se encuentre alineado con la leng eta de la base Utilice el tornillo conservado con anterioridad para sujetar el conducto en su lugar a trav s de la leng eta de la base del artefacto C MO AGREGAR CODOS Y CONDUCTOS DE SALIDA HACIA LA IZQUIERDA O DERECHA DEL GABINETE e Arme previamente un codo de 4 c
12. Installation Electric Dryer Instructions 01 Questions on Installation Call 800 GE CARES US or visit our Web site at www GEAppliances com US BEFORE YOU BEGIN AWARNING risk oF FIRE Read these instructions completely and e l carefully To reduce the risk of severe injury or death follow all installation instructions e IMPORTANT Save these instructions Clothes dryer installation must be performed by a qualified installer for local inspector s use Install the clothes dryer according to these instructions and in accordance e IMPORTANT Observe all governing with local codes codes and ordinances This dryer must be exhausted to the outdoors Note to Installer Be sure to leave these Use only rigid metal 4 diameter ductwork inside the dryer cabinet and use instructions with the customer only UL approved transition ducting between the dryer and the home duct Note to Customer Keep these instructions DO NOT install a clothes dryer with flexible plastic ducting materials If with your Owner s Manual for future flexible metal semi rigid or foil type duct is installed it must be UL listed reference and installed in accordance with the instructions found in Connecting Before the old dryer is removed from service The Dryer To House Vent on pages 4 5 of this manual Flexible venting or discarded remove the dryer door materials are known to collapse be easily crushed and trap lint These Service information and the wiring diagram co
13. P EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only for short run installations 90 Feet 60 Feet 60 Feet 45 Feet 45 Feet 35 Feet 35 Feet 25 Feet 25 Feet 15 Feet For every extra 90 elbow reduce the allowable vent system length by 10 ft Two 45 elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart The total vent system length includes all the straight portions and elbows of the system transition duct included e Terminate in a manner to prevent back drafts or entry of birds or other wildlife e Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging Never install a screen in or over the exhaust duct This could cause lint build up Wall caps must be installed at least 12 in above ground level or any other obstruction with the opening pointed down Installation Instructions EXHAUST SYSTEM CHECK LIST cont SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN 90 e One turn of 45 or less may be ignored e Two 45 turns should be treated as one 90 turn e Each turn over 45 should be treated as one 90 turn SEALING OF JOINTS e All joints should be tight to avoid leaks The male end of each section of duct must point away from th
14. a connexi n el ctrica a tierra por el medio del cable neutral 1 Desactive el interruptor de circuitos 30 amperios o quite el fusible del circuito de la secadora de la caja el ctrica 2 Verifique que el cable de la secadora est desenchufado del tomacorriente Quite la tapa del cable de energ a ubicada en la parte trasera inferior Instale un alivio de tensi n de 34 pulgadas reconocido por UL en el orificio de entrada del cable de energ a Pase el cable de energ a a trav s del alivio de tensi n Conecte el cable de energ a de la siguiente manera A Conecte los dos cables vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutral blanco al centro del bloque terminal marcado N Aseg rese de que la cinta de conexi n a tierra est conectada a la terminal neutral central del bloque y al tornillo verde de conexi n a tierra de la parte trasera del gabinete Ajuste por firmemente todos los tornillos 3 del bloque terminal Ajuste bien el cable de energ a al alivio de tensi n Vuelva a instalar la tapa AADVERTENCIA NUNCA OLVIDE DE VOLVER A COLOCAR LA TAPA DEL BLOQUE TERMINAL Instrucciones de instalaci n 3 INFORMACION DE SALIDA A ADVERTENCIA EN CANAD Y LOS ESTADOS UNIDOS EL DI METRO DE CONDUCTO DE SALIDA REQUERIDO ES DE 4 PULG 102 mm NO UTILICE UN CONDUCTO DE UNA LONGITUD MAYOR A LA ESPECIFICADA EN LA TABLA DE LONGITUD DE SALIDA Al u
15. ablecida por un electricista calificado Conecte de acuerdo con la ilustraci n del bloque terminal que corresponde a su secadora Cable vivo Tornillo 3 conductores Tornillo de cobre 10 Cinta de AWG m nimo O y o kit de cable a tierra 8 de suministro Tornillo E de energ a de verde de f 120 240V 30A conexion 4 y marcado para su a terra uso con secadoras Neutral y provisto con blanco anA Soporte terminales de Cable Tornillo Alivio de q AS tensi n e bucle cerrado de 3 4 alivio o hembra reconocido Je conextremos por UL tensi n hacia arriba no provistos VIVO Tornillo Cable vivo 3 conductores Tornillo de cobre 10 Cinta de ae AWG minimo ee NE o kit de cable a tierra opa de suministro Tornillo de energ a de verde de i 3 120 240V 30A conexion E marcado para su uso con secadoras y provisto con Cable Alivio de Soporte terminales de Tornillo yga tensi n de bucle cerrado de 3 4 alivio o hembra reconocido de con extremos por UL tensi n hacia arriba no provistos a tierra Z Neutral blanco Conexi n de 3 cables NO usar en Canad NO usar en instalaciones en casas m viles NO usar en casas nuevas NO usar en veh culos recreativos NO usar en reas donde los c digos locales proh ben l
16. as de espacio abierto distribuido uniformemente NOTA CUANDO EL CONDUCTO DE SALIDA EST UBICADO EN LA PARTE TRASERA DE LA SECADORA EL ESPACIO LIBRE MINIMO DESDE LA PARED DEBE SER 5 5 PULGADAS 7 INSTALACION EN BANOS O DORMITORIOS e Esta secadora DEBE tener una ventilaci n al exterior Ver la INFORMACI N SOBRE SALIDA secciones 3 y 4 e La instalaci n debe cumplir con c digos locales o si no existieran con el C DIGO EL CTRICO NACIONAL ANSI NFPA N 70 8 INSTALACION EN CASAS M VILES O PREFABRICADAS ela instalaci n debe cumplir con la NORMA SOBRE CONSTRUCCI N Y SEGURIDAD DE CASAS PREFABRICADAS T TULO 24 PARTE 32 80 o cuando dicha norma no sea aplicable con la NORMA NACIONAL ESTADOUNIDENSE PARA CASAS M VILES ANSI NFPA N 5018 ela secadora DEBE tener ventilaci n al exterior con la terminaci n bien sujeta a la estructura de la casa m vil Ver la INFORMACI N SOBRE SALIDA secciones 3 y 4 eLa ventilaci n NO DEBE terminar debajo de una casa m vil o prefabricada e El material del conducto de ventilaci n DEBE SER METAL e No utilice tornillos para placas de metal u otros dispositivos de sujeci n que se extiendan al interior de la ventilaci n de salida e Ver la secci n 2 sobre informaci n sobre conexiones el ctricas POR LOS CODIGOS LOCALES Secadoras instaladas en garages deben ser elevadas 18 pulgadas 46cm del nivel del piso 9 INSTALACI N EN GARAJE SI PERM
17. conducto flexible de metal semi r gido o de tipo papel de aluminio debe estar aprobado por UL e instalarse de acuerdo con las instrucciones de C mo conectar la secadora a la ventilaci n dom stica de las p ginas 4 5 de este manual Los materiales de ventilaci n flexibles a menudo se desploman se aplastan y atrapan pelusas Estas condiciones obstruyen la corriente de aire de la secadora e incrementan el riesgo de incendio No instale o almacene este aparato en un lugar donde se vea expuesto al agua y o a las inclemencias del tiempo Guarde estas instrucciones Instaladores Aseg rese de dejar estas instrucciones al consumidor OTA La instalaci n y reparaci n de esta secadora requieren control de la secadora capacidades mec nicas y el ctricas b sicas Es su responsabilidad La garant a no cubre las fallas del producto contactar a un instalador calificado para realizar las conexiones debido a una instalaci n incorrecta el ctricas HERRAMIENTAS MATERIALES NECESARIOS NECESARIAS RECOMENDADO ESSE CONDUCTO DE METAL DE 4 DE DIA O ZI KIT DE CABLE ALICATES DE JUNTA DESLIZANTE DESTORNILLADOR PLA CONDUCTO DE TRANSICION APROBADO POR UL SI FUERA ONDUCTO DE TRANSIC FLEXIBLE SEMI R GIDO DE 4 DE DI DE RESORTE DE 4 2 ABRAZADERAS CODO DE METAL DE ENERGIA OD DI DE CONDUCTO DE 4 2 DE4 DEDIA CAMPANA GAFAS DE LA SECADORA 0 DESALIDA DESEGURIDAD INO PROVISTA CON DEMETAL ABRAZADER
18. crew 3 10 AWG minimum copper conductors or 120 240V 30A power supply cord kit marked for use with dryers and provided with Strain closed loop or Relief spade terminals Bracket with upturned ends not supplied Green ground screw Neutral white Hot Wire Screw 3 4 U Recognized Strain Relief Hot Wire 3 10 AWG minimum copper conductors or 120 240V 30A power supply cord kit marked for use with dryers and provided with Strain closed loop or Relief spade terminals Bracket with upturned ends not supplied Screw Ground Strap Green ground screw Neutral white Screw Hot 3 4 UL Wire Recognized Strain Relief 3 wire Connection Not for use in Canada DO NOT use for Mobile Home Installations NOT for use on new construction NOT for use on recreational vehicles NOT for use in areas where local codes prohibit grounding through the neutral conduction L Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box Be sure the dryer cord is unplugged from the wall Remove the power cord cover located at the lower back Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief Connect power co
19. e dryer The duct shall not be assembled with screws or other fastening means that extend into the duct and catch lint Duct joints can be made air and moisture tight by wrapping the overlapped joints with duct tape Horizontal runs should slope down toward the outdoors 1 4 inch per foot INSULATION Duct work that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint build up EXHAUST CONNECTION AWARNING TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY e This clothes dryer must be exhausted to the outdoors e Use only 4 rigid metal ducting for the home exhaust duct e Use only 4 rigid metal or UL listed flexible metal semi rigid or foil type duct to connect the dryer to the home exhaust duct It must be installed in accordance with the instructions found in Connecting the Dryer to House Vent on pages 4 5 of this manual e Do not terminate exhaust in a chimney a wall a ceiling gas vent crawl space attic under an enclosed floor or in any other concealed space of a building The accumulated lint could create a potential fire hazard Never terminate the exhaust into a common duct with a kitchen exhaust system A combination of grease and lint creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the
20. es por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores locales IMPORTANTE siga todos los c digos y ordenanzas vigentes Nota al instalador Aseg rese de dejar estas instrucciones con el consumidor Nota al consumidor Mantenga estas instrucciones con el Manual del Propietario para referencia futura Antes de que la secadora antigua sea retirada del servicio o eliminada qu tele la puerta La informaci n sobre reparaciones y el diagrama del cableado se encuentran en la consola de control No permita que ni os se suban o se metan dentro del aparato Se requiere una supervisi n estricta cuando el aparato es utilizado cerca de ni os Instale la secadora en lugares donde la temperatura sea mayor a 50 para un funcionamiento satisfactorio del sistema de N Para reducir el riesgo de una lesi n grave o de muerte cumpla con todas las instrucciones de instalaci n La instalaci n de la secadora debe efectuarla un instalador calificado nstale la secadora de ropa de acuerdo con estas instrucciones y en cumplimiento de los c digos locales Esta secadora debe tener una salida al exterior Utilice s lo un conducto r gido de metal de un di metro de 4 dentro del gabinete de la secadora y use s lo un conducto de transici n aprobado por UL entre la secadora y el conducto dom stico NO instale una secadora de ropa con conductos de pl stico flexibles Si se instala un
21. ica 2 Verifique que el cable de la secadora est desenchufado del tomacorriente 3 Quite la tapa del cable de energ a ubicada en la parte trasera inferior 4 Quite y descarte la cinta de conexi n a tierra Conserve el tornillo verde de conexi n a tierra para el paso 7 5 Instale un alivio de tensi n de pulgadas reconocido por UL en el orificio de entrada del cable de energ a Pase el cable de energ a a trav s del alivio de tensi n 6 Conecte el cable de energ a de la siguiente manera A Conecte los dos cables vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutral blanco al centro del bloque terminal marcado N 7 Conecte el cable a tierra del cable de energ a con el tornillo verde de conexi n a tierra orificio sobre el soporte de alivio de tensi n Ajuste por firmemente todos los tornillos 3 del bloque terminal 8 Ajuste bien el cable de energ a al alivio de tensi n 9 Vuelva a instalar la tapa A ADVERTENCIA NUNCA OLVIDE DE VOLVER A COLOCAR LA TAPA DEL BLOQUE TERMINAL Tornillo Instrucciones de instalaci n C MO CONECTAR LA SECADORA UTILIZANDO UNA CONEXI N DE 3 CABLES Si as lo requirieran los c digos locales instale una conexi n a tierra externa no provista a metal con conexi n a tierra tuber as de agua fr a con conexi n a tierra u otra conexi n a tierra est
22. incendio eNo utilice un conducto de una longitud mayor a la especificada en la tabla de longitud de salida Los conductos m s largos acumulan pelusa lo que genera un riesgo potencial de incendio e Nunca instale un filtro dentro o sobre el conducto de salida Esto provocar la acumulaci n de pelusas lo que genera un riesgo potencial de incendio eNo arme la red de conductos con sujeciones que se extiendan dentro del conducto Estas sujeciones pueden acumular pelusa lo que genera un riesgo potencial de incendio e No obstruya el aire que entra y sale e Incluya un acceso para inspecci n y limpieza del sistema de salida especialmente en las curvas y juntas El sistema de salida debe inspeccionarse y limpiarse por lo menos una vez al a o Existen opciones m ltiples de instalaci n Seleccione el m todo m s apropiado para su instalaci n SALIDA TRASERA EST NDAR Ventilaci n a nivel del suelo Para una instalaci n en l nea recta conecte la salida de la secadora a la campana de salida al exterior con cinta aislante o una abrazadera ABERTURA DE CONDUCTO EXTERIOR CINTA AISLANTE O ABRAZADERA DE CONDUCTO J CONDUCTO DE METAL DE 4 CORTADO CON LA LONGITUD ADECUADA CINTA AISLANTE O ABRAZADERA DE CONDUCTO NOTA RECOMENDAMOS ENF TICAMENTE EL USO DE CONDUCTOS DE SALIDA DE METAL SOLIDO SIN EMBARGO SI SE USAN CONDUCTOS FLEXIBLES ESTOS DEBEN SER DE METAL APROBADOS POR UL NO DE PLASTICO S
23. istema de escape incluye todas las porciones rectas ytodos los codos del sistema incluyendo el ducto de transici n e Instale la salida de modo de evitar contracorrientes o el ingreso de p jaros u otros insectos o animales e La boca de salida debe presentar una resistencia minima al flujo de salida y debe requerir poco o ning n mantenimiento para evitar las obstrucciones e Nunca instale un filtro dentro o sobre el conducto de salida Esto podr a provocar una acumulaci n de pelusa Instrucciones de instalaci n LISTA DE CONTROL DEL SISTEMA DE SALIDA cont e Las cubiertas de pared deben instalarse por lo menos a 12 sobre el nivel del suelo o cualquier otra obstrucci n con la abertura apuntando hacia abajo SEPARACI N DE CURVAS Para un mejor desempe o separe todas las curvas con por lo menos 4 pies de conducto recto incluyendo la distancia entre la ltima curva y la campana de salida GIROS QUE NO SON DE 90 e Un giro de 45 o menos puede ignorarse e Dos giros de 45 deben tratarse como un giro de 90 e Todos los giros de m s de 45 deben tratarse como un giro de 90 SELLADO DE JUNTAS e Todas las juntas deben estar bien selladas para evitar p rdidas El extremo macho de cada secci n de conducto debe apuntar en direcci n opuesta a la secadora El conducto no deber instalarse con tornillos u otros medios de sujeci n que se extiendan dentro del conducto y enganchen pelusas Las juntas de los
24. lation Minimum clearance to combustible surfaces and for air opening are 0 in clearance both sides 1 in front and 3 in rear Consideration must be given to provide adequate clearance for installation and service Printed in Mexico 254D2008P001 3531 16714 03 13 GE Installation Instructions PREPARING FOR INSTALLATION OF NEW DRYER TIP Install your dryer before installing your washer This will allow better access when installing dryer exhaust REMOVING LINT FROM WALL EXHAUST OPENING e Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct INTERNAL DUCT CHECKTHAT EXHAUST OPENING HOOD DAMPER OPENS AND CLOSES FREELY TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING THEM AWAY FROM THE DRYER LEGS BE SURE TO REMOVE ALL OF THE FOAM PIECES AROUND THE LEGS ELECTRICAL CONNECTION INFORMATION AAWARNING To REDUCE THE RISK OF FIRE ELECTRICAL SHOCK AND PERSONAL INJURY e DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE Dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes in accordance with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 ELECTRICAL REQUIREMENTS This dryer must be connected to an individual branch circuit protected by the required time delay fuses or circuit breakers A four or three
25. n a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed NOTE WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER MINIMUM CLEARANCE FROM THE WALLIS 5 5 in Installation Instructions BATHROOM OR BEDROOM INSTALLATION e The dryer MUST be vented to the outdoors See EXHAUST INFORMATION section 3 amp 4 e The installation must conform with local codes or in the absence of local codes with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 MOBILE OR MANUFACTURED HOME INSTALLATION e Installation must conform to the MANUFACTURED HOME CONSTRUCTION amp SAFETY STANDARD TITLE 24 PART 32 80 or when such standard is not applicable with AMERICAN NATIONAL STANDARD FOR MOBILE HOME ANSI NFPA NO 5018 eThe dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home structure See EXHAUST INFORMATION section 3 amp 4 eThe vent MUST NOT be terminated beneath a mobile or manufactured home e The vent duct material MUST BE METAL e Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent e See section 2 for electrical connection information GARAGE INSTALLATION IF ALLOWED BY LOCAL CODES Dryers installed in garages must be elevated 18 inches 46cm above the floor
26. nditions will obstruct dryer airflow and increase the risk of fire are located in the control console Do not install or store this appliance in any location where it could be Do not allow children on or in the appliance exposed to water and or weather Close supervision of children isnecessary Save these instructions Installers Be sure to leave these instructions when the appliance is used near children with the customer Install the dryer where the temperature is ps ETOT AS NOTE Installation and service of this dryer requires basic ryer control system Product failure due to improper installation mechanical and electrical skills It is your responsibility to contact is not covered under the Warranty a qualified installer to make the electrical connections TOOLS YOU MATERIALS YOU WILL NEED WILL NEED as lt gt 4 DIA METAL DUCT SLIP JOINT PLIERS RECOMMENDED COUT A METAL CLAMPS 2 GBON EXHAUST SAFETY DRYER POWER a so ass i FLAT BLADE SCREWDRIVER 4 DIA O D J 4 SPRING WITH DRYER UL LISTED TRANSITION DUCT IF NEEDED CLAMPS 2 UL RATED KIT WX08X10077 INCLUDES 2 ELBOWS ma 120 240V 308 PHILLIPS SCREWDRIVER Q E e l w 3 4 STRAN IDENTIFY THE PLUG Fi DUCT TAPE id daa HOUE FCE 4 DIA FLEXIBLE METAL FOIL TYPE uLRECOGNZED HOUSE RECERTACLE D gt UL LISTED TRANSITION DUCT 4 COVER PLATE IF NEEDED IF NEEDED LINE CORD LEVEL KIT WE1M454 Minimum Clearance Other Than Alcove or Closet Instal
27. ng and kinking UL LISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT e f rigid metal duct cannot be used then UL listed flexible metal semi rigid ducting can be used Kit WX08X10077 e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m Installation Instructions e For many applications installing elbows at both the dryer For best drying performance and the wall is highly recommended see illustrations 1 Slide one end of the duct over the clothes dryer outlet below Elbows allow the dryer to sit close to the wall ae the duct with a clamp without kinking and or crushing the transition duct 3 With the dryer in its permanent position extend the duct maximizing drying performance to its full length Allow 2 of duct to overlap the exhaust e Avoid resting the duct on sharp objects pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT 4 Secure the duct to the exhaust pipe with the other clamp e In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible 5 LEVELING AND STABILIZING YOUR metal
28. on un conducto de 4 Coloque cinta aislante alrededor de la junta e Introduzca el montaje del conducto el codo primero a trav s de la abertura lateral y conecte el codo al conducto interno de la secadora A PRECAUCI N Aseg rese de no tirar o da ar los cables el ctricos ubicados dentro de la secadora cuando introduzca el conducto LA SALIDA PUEDE AGREGARSE A LOS LADOS DERECHO O IZQUIERDO AISLANTE e Aplique cinta aislante como puede verse en la junta entre el conducto interno de la secadora y el codo CINTA APRECAUCION Las juntas del conducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad COMO AGREGAR UN CODO DE SALIDA A TRAVES DE LA PARTE INFERIOR DEL GABINETE e Introduzca el codo a trav s de la abertura trasera y con ctelo al conducto interno de la secadora e Aplique cinta aislante en la junta entre el conducto interno de la secadora y el codo como puede verse abajo W Win NN Sut PRECAUCI N Las juntas del conducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad C MO AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABINETE SALIDAS POR LOS LADOS Y LA PARTE INFERIOR PLACA KIT WE1M454 Conecte los codos y conductos de metal est ndar para completar el sistema de salida Cubra la abertura trasera con la placa Kit WE1M454 disponible en su proveedor de servicio
29. rd as follows A Connect the 2 hot lines to the outer screws of the terminal block marked L1 and L2 B Connect the neutral white line to the center of the terminal block marked N Be sure ground strap is connected to neutral center terminal of block and to green ground screw on cabinet rear Tighten all terminal block screws 3 securely 7 Properly secure power cord to strain relief Reinstall the cover AWARNING never LEAVE THE COVER OFF OF THE TERMINAL BLOCK Installation Instructions EXHAUST INFORMATION AAWARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4 in 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will e Increase the drying times and the energy cost e Reduce the dryer life e Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST SYSTEM CHECK LIST HOOD OR WALL CA
30. s local Coloque la secadora en su ubicaci n final A ADVERTENCIA NUNCA DEJE LA ABERTURA TRASERA SIN LA PLACA EN SU LUGAR Kit WE1M454 REGISTRE SU NUEVO APARATO PARA RECIBIR LAS NOTIFICACIONES DE PRODUCTOS IMPORTANTES Por favor vaya a www GEAppliances com o enviar por correo su tarjeta de inscripci n Para preguntas sobre la instalaci n llame al 800 626 2000 EE UU o 800 561 3344 Canada
31. talaciones especiales puede ser necesario conectar la secadora a la ventilaci n dom stica utilizando un conducto de metal flexible tipo papel de aluminio Puede utilizarse un conducto de metal flexible tipo papel de aluminio aprobado por UL S LO en instalaciones en las que no pueden usarse conductos de metal r gidos o flexibles semi r gidos Y en las que puede mantenerse un di metro de 4 a lo largo de todo el conducto de transici n e En Canad y los Estados Unidos solamente deber n utilizarse los conductos de metal flexibles tipo papel de aluminio que cumplan con el Resumen para conductos de transici n para secadoras de ropa Tema 2158A METAL FLEXIBLE RECOMIENDA ENFATICAMENTE L e Nunca instale conductos de metal flexibles en paredes cielorrasos pisos u otros espacios cerrados eLa longitud total del conducto de metal flexible no deber superar los 8 pies 2 4 m e No coloque el conducto sobre objetos afilados AY NO COLOQUE LA SECADORA SOBRE UNA SALIDA FLEXIBLE DY Y MUY amp NO UTILICE UNA LONGITUD DE SALIDA EXCESIVA NO APLASTE LA SALIDA FLEXIBLE Para un mejor desempe o de secado 1 Deslice un extremo del conducto sobre la tuber a de salida de la secadora de ropa 2 Fije el conducto con una abrazadera 3 Con la secadora en su posici n permanente extienda el conducto en su longitud total Deje que se superpongan 2 de conducto con la tuber a de salida Corte y q
32. th upturned ends not supplied 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at the lower back 4 Remove and discard ground strap Keep the green ground screw for step 7 5 Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief 6 Connect power cord as follows A Connect the 2 hot lines to the outer screws of the terminal block marked L1 and L2 B Connect the neutral white line to the center of the terminal block marked N 7 Attach ground wire of power cord with the green ground screw hole above strain relief bracket Tighten all terminal block screws 3 securely 8 Properly secure power cord to strain relief 9 Reinstall the cover AWARNING never LEAVE THE COVER OFF OF THE TERMINAL BLOCK sol ground Neutral z screw white A A E Screw 4 UL Strain Hot Wire Recognized Relief Strain Relief Bracket Installation Instructions CONNECTING DRYER USING 3 WIRE CONNECTION If required by local code install external ground not provided to grounded metal cold water pipe or other established ground determined by a qualified electrician Wire according to the terminal block illustration that matches your dryer Hot Wire S
33. tilizar una salida de mayor longitud a la especificada se e Incrementar n los tiempos de secado y el costo de energ a e Reducir la vida util de la secadora e Acumular pelusa lo que podria generar un riesgo potencial de incendio La correcta instalaci n de salida es SU RESPONSABILIDAD Los problemas generados por una instalaci n incorrecta no se encuentran cubiertos por la garant a Quite y descarte el conducto de transici n existente de pl stico o de papel de aluminio y coloque un conducto de transici n aprobado por UL La longitud MAXIMA PERMITIDA del conducto y la cantidad de codos del sistema de salida dependen del tipo de conducto la cantidad de curvas la clase de campana de salida cubierta de pared y todas las condiciones indicadas a continuaci n La longitud m xima del conducto para conductos r gidos de metal se indica en la siguiente tabla LISTA DE CONTROL DEL SISTEMA DE SALIDA CAMPANA O CUBIERTA DE PARED LONGITUD DE SALIDA LONGITUD M XIMA RECOMENDADA Tipos de campana de salida Utilizar s lo en instalaciones Recomendado de trayecto corto codos de 90 Rigido Rigido 0 90 Pies 60 Pies 1 60 Pies 45 Pies 2 45 Pies 35 Pies 3 35 Pies 25 Pies e Para cada codo adicional de 90 reduzca en 10 pies la longitud permisible del sistema de escape e Dos codos de 45 deber n ser considerados como un codo de 90 e Para el escape lateral agregue un codo de 90 a la tabla e La longitud total del s
34. uite el tramo de conducto que sobre Mantenga el conducto lo m s recto posible para lograr una corriente de aire m xima 4 Fije el conducto a la tuber a de salida con la otra abrazadera C MO NIVELAR Y ESTABILIZAR SU SECADORA NIVELAR NIVELAR Coloque la secadora FRENTE A PARTE TRASERA LADO A LADO en posici n vertical cerca de la ubicaci n definitiva y ajuste las cuatro patas de nivelaci n en los extremos para garantizar que la secadora se encuentre nivelada de lado a lado y del frente a la parte trasera 4PATAS DE NIVELACION Instrucciones de instalaci n 6 INSTALACI N EN NICHO O EN CLOSET eSu secadora puede instalarse en un nicho o closet como se indica en la etiqueta de la parte trasera del aparato e Esta secadora DEBE tener una ventilaci n al exterior Ver la INFORMACI N SOBRE SALIDA secciones 3 y 4 e El espacio libre m nimo entre el gabinete de la secadora y las paredes adyacentes u otras superficies es de O pulg sobre ambos lados 3 pulg en el frente 3 pulg en la parte trasera e El espacio vertical m nimo desde el piso a los gabinetes superiores cielorraso etc es de 52 pulg e Las puertas del closet deben contar con rejillas u otro tipo de ventilaci n y deben tener por lo menos 60 pulg cuadradas de espacio abierto igualmente distribuido Si el closet incluye una lavadora y una secadora las puertas deben contener un m nimo de 120 pulg cuadrad