Owner`s Manual AIR COMPRESSOR
Contents
1. eueeeeeeeeeee 32 56 NOTES NOTAS eeee 57 REPAIR PROTECTION AGREEMENTS 58 HOW TO ORDER REPAIR PARTS back cover WARRANTY ONE YEAR FULL WARRANTY If this product fails due to a defect in material or workmanship within one year from the date of purchase Sears will at its option repair or replace it free of charge Contact Sears at 1 800 4 MY HOME to arrange for repair or return it to the place of purchase for replacement If this product is used for commercial or rental purposes this warranty applies for only ninety days from the date of purchase This warranty gives you specific legal rights and you may have other rights which vary from state to state Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 A17893 2 ENG For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 SPECIFICATION CHART For replacement parts contact Model No 919 167281 Running HP 2 0 Bore 2 38 Stroke 1 35 Voltage Single Phase 120V 60HZ 1PH Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity 26 Approx Cut In 120 Approx Cut out 150 SCFM 40 psig 8 6 SCFM 90 psig 6 4 Refer to Glossary for abbreviations SAFETY GUIDELINES DEFINITIONS This manual contains information that is important for
2. 58 COMO SOLICITAR PIEZAS PARA REPARACI N contratapa GARANTIA GARANT A TOTAL DE UN A O Si esta unidad fallase debido a defectos de materiales o de fabricaci n dentro del a o de su fecha de compra Sears a su opci n lo reparar o reemplaz ara sin costo alguno Comun quese con Sears al 1 800 4 MY HOME para coordinar su reparaci n o devuelva la unidad al lugar donde lo compr para que lo cambien Si esta unidad se usase con fines comerciales o para alquiler esta garant a se aplica s lo durante los primeros noventa d as a partir de su fecha de compra Esta garant a le otorga derechos espec ficos y usted podr a tener otros dere chos que var an de un estado a otro Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 A17893 28 SP CUADRO DE ESPECIFICACIONES Modelo N HP de Trabajo Diametro interior Carrera Tension monofasica Circuito minimo requerido Tipo de fusible Accion retardada Capacidad de aire en el tanque Presi n de corte de entrada Presi n de corte de salida 919 167281 2 0 2 38 po 60 4mm 1 35 po 34 3mm 120V 60HZ 1PH 15A 26 Galones 124 9 litros 120 150 SCFM a 40 psig 8 6 Calibre de libras por pulgada cuadrada 6 4 Calibre de libras por pulgada cuadrada SCFM a 90 psig Refi rase al glosario para descifrar las abreviaturas DEFINICIONES DE NORMAS DE SEGURIDAD Este manual contiene informacion que es importante que usted c
3. 3 Remueva la herramienta neum tica o el accesorio 4 Tire del aro de la v lvula de seguridad dejando purgar el aire del tanque hasta que este reduzca su presi n aproximadamente a 20 PSI Suelte el aro de la v lvula de seguridad 5 Drene el agua contenida en el tanque de aire abriendo la v lvula de drenaje ubicada en la base del tanque en sentido contrario a las agujas de reloj NME Riesgo de Explosion Dentro del tanque se producira condensacion de agua Si no drena el agua lo corroera y debilitara causando un riesgo de ruptura del tanque de aire A17893 6 Una vez drenada el agua cierre la valvula de drenaje girando en sentido horario Ahora el compresor de aire podra ser guardado NOTA Si la valvula de drenaje fuera del tipo enchufe elimine toda la presi n de aire La v lvula podr entonces ser ex tra da limpiada y finalmente reinstalada Filtro de Aire Inspecci n y reemplazo Waaa Riesgo de quemaduras El cabezal y la manga del cilindro del compresor se calientan mucho no tocarlos Permitir que el compresor se enfr e antes de darle servicio Un filtro de aire sucio no permitir que el compresor opere a plena capacidad Mantenga el filtro de aire limpio en todo momento 1 Extraiga el ret n del filtro de aire A17893 IMPORTANTE No opere el compresor sin el filtro de aire 2 Retire el filtro de aire y aseg rese de que est limpio 3 Si esta sucio enjuague el fil
4. capable of running continuously cycle be maintained that is the air However to prolong the life of your compressor pump should not run air compressor it is recommended more than 30 45 minutes in any given hour 9 ENG A17893 For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact For replacement parts contact www allpartsinc com ASSEMBLY ere Remove unit from carton and discard all packaging INSTALLATION HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean dry and well ventilated area The air compressor should be located at least 12 away from the wall or other obstructions that will interfere with the flow of air The air compressor pump and shroud are designed to allow for proper cooling The ventilation Openings on the compressor are necessary to maintain proper operating temperature Do not place rags or other containers on or near these openings GROUNDING INSTRUCTIONS INN NIN Risk of Electrical ock In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compres sor must be properly grounded The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug see following illustra tions 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with
5. AWARNING To Replace or Clean Check Valve 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Set the On Auto Off lever to OFF and unplug unit 3 Using an adjustable wrench loosen outlet tube nut at air tank and pump Carefully move outlet tube away from check valve Pressure Relief Tube 4 Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch Carefully move pressure relief tube away from check valve 5 Unscrew the check valve turn counterclockwise using a 7 8 open end wrench Note the orientation for reassembly 6 Using a screwdriver carefully push the valve disc up and down NOTE The valve disc should move freely up and down ona spring which holds the valve disc in the closed position if not the check valve needs to be cleaned or replaced position nothing is visible 10 11 17 ENG www allpartsinc com In closed position disc is visible Clean or replace the check valve A solvent such as paint or varnish remover can be used to clean the check valve Apply sealant to the check valve threads Reinstall the check valve turn clockwise Replace the pressure release tube Tighten nuts Replace the outlet tube and tighten nuts Perform the Break in Procedure See Break in Procedure in the Operation section A17893 1 877 475 5660 For replacement parts contact www allpartsi
6. Quick Connect Plug Start Capacitor Kit A O Smith Motor Start Capacitor Kit Ge Motor Start Capacitor Kit Weg Motor Inflate Deflate Kit Start Run Capacitor Kit Ge Motor Torque to 100 120 in lbs Torque set screw to 42 48 in lbs Torque to 7 10 ft lbs Torque to 51 63 in lbs For replacement parts contact 27 ENG www allpartsinc com QTY bb 3223 32 gt gt 1 1 1 1 1 A17893 1 877 475 5660 CONTENIDO GARANT A 0000 cece cece eee eee eee eee eee a 32 CUADRO DE ESPECIFICACIONES 33 DEFINICIONES DE NORMAS DE SEGURIDAD 33 IMPORTANTES INSTRUCCIONES DE SEGURIDAD 34 38 GLOSARIO wanwann 39 ACCESORIOS wwan wan 39 CICLODESERVICIO 39 ENSAMBLADO eee eee eee eee eee 40 INSTALACI N 222 2 22 2 ee 41 43 OPERACI N eee eee 44 46 MANTENIMIENTO wamwa mwan 47 50 SERVICIOS YREGULACIONES 51 52 ALMACENAJE mwanana mwan 52 GU A DE DIAGN STICO DE PROBLEMAS 53 56 NOTES NOTAS wwmwanwa mwa w wanawa n 57 LISTADEPARTES w wanan 28 31 CONTRATOS DE PROTECCION PARA REPARACIONES
7. Replacement MUZIKI Tewa Risk of Burns Compressor head and cylinder sleeve are very hot Do not touch Allow compressor to cool prior to servicing A dirty air filter will not allow the compressor to operate at full Capacity Keep the air filter clean at all times 1 Remove the air filter and make sure it is clean A17893 For replacement parts contact www allpartsinc com www allpartsinc com 1 877 475 5660 IMPORTANT Do not operate the compressor with the air filter re moved 2 If dirty rinse air filter with warm water and squeeze dry 3 Replace air filter NOTE If the air filter is extremely dirty it will need to be replaced Refer to the Repair Parts for the correct part number Air Compressor Pump Intake and Exhaust Valves Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves 16 ENG 1 877 475 5660 For replacement parts contact For replacement parts contact www allpartsinc com 1 877 475 5660 SERVICE AND ADJUSTMENTS All maintenance and repair opera tions not listed must be performed by Trained Service Technician Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconnect electrical supply to the air compressor bleed tank of pressure and allow the air compressor to cool
8. Store flammable materials in a secure location away from compressor Never place objects against or on top of compressor Operate compressor in an open area at least 12 inches away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings Operate compressor in a clean dry well ventilated area Do not operate unit indoors or in any confined area Always remain in attendance with the product when it is operating Always disconnect electrical power by moving pressure switch lever to the off position and drain tank daily or after each use 4 ENG 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 HAZARD WARNING Risk of Bursting Air Tank The following conditions could lead to a weakening of the tank and result in a violent tank explosion and could cause property damage or serious injury What Could Happen Failure to properly drain condensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Excessive vibration can weaken the air tank and cause rupture or explosion ATTACHMENTS amp ACCESSORIES Exceeding the pressure rating of air tools spray guns air operated accessories tires and other inflatables can cause them to explode or fly apart and coul
9. lvula de seguridad 6 Drene el agua del tanque de aire abriendo la v lvula de drenaje ubicada en el fondo del tanque 45 SP a Riesgo de Explosi n El agua se condensa dentro del tanque de aire Si no se drena ella corroer debilitando la paredes del tanque de aire originando un riesgo de ruptura de sus paredes 7 Una vez que el agua haya sido drenada cierre la v lvula de drenaje NOTA Si la v lvula de drenaje estuviese enchufada libere toda la presi n de aire La v lvula podr ser extra da limpiada y luego reinstalada 8 Proteja el cable el ctrico y las mangueras de aire de da os tales como ser pisoteados o pasados por encima Enr llelos en forma floja alrededor de la manija del compresor Si estuviera equipado con ella 9 Almacene el compresor de aire en un sitio limpio y seco A17893 For replacement parts contact For replacement parts contact www allpartsinc com 1 877 475 5660 GUIA DE DIAGNOSTICO DE PROBLEMAS ADVERTENCIA Riesgo de Operacion Insegura La unidad arranca automaticamente cuando esta enchufada Al hacer el mantenimiento el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles Antes de intentar hacer reparaciones desconectar el compresor del tomacorriente drenar la presi n de aire del tanque y esperar a que el compresor se enfr e CAUSA El interruptor de presi n no interrumpe al motor cuando e
10. regulada bajo condiciones de flujo mientras se est usando el accesorio Opere la v lvula de seguridad manualmente tirando de su anillo Si la v lvula aun pierde deber ser reemplazada Extraiga y limpie o reemplace Disminuya la cantidad de uso de aire Verifique el requerimiento de aire del accesorio Si es mayor que SCFM o la presi n suministrada por su compresor de aire se necesita un compresor de mayor capacidad Verifique y reemplace si fuese necesario Extraiga limpie o reemplace Ajuste las conexiones Limpie o reemplace el filtro de entrada de aire No opere el com presor de aire sin el filtro Consulte el p rrafo Filtro de Aire en la secci n Mantenimiento Reemplace Reemplace A17893 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 PROBLEMA CAUSA CORRECCION El motor no El interruptor de protecci n des Deje enfriar el motor y el interrup funciona obrecarga del motor se ha tor de sobrecarga se reajustar abierto autom ticamente La presi n del tanque excede El motor arrancar autom ticamente la presi n de corte m ximo cuando la presi n del tanque caiga del interruptor de presi n por debajo de la presi n de corte m xima del interruptor de presi n El cord n de extensi n es del Compruebe el calibre y la longitud largo o calibre equivocados apropiados del cord n La v lvula de retenci n se ha Extraiga limpie o reemplace que
11. riesgo de explosion Verifique los valores de maxima presion dados por el fabricante de las herramientas neumaticas y los accesorios La presi n de salida del regulador jam s debe exceder los valores de m xima presi n especificados A17893 C mo poner en marcha 1 Mueva la palanca On Auto Off a la posici n AUTO y deje que se incremente la presi n del tanque El motor se detendr una vez alcanzado el valor de presi n de corte del tanque 2 Tire de la perilla del regulador y gire en sentido horario para incrementar la presi n Cuando el valor deseado de presi n sea logrado presione la perilla hasta su posici n blocante El compresor estar listo para ser usado NOTA Opere siempre el compresor de aire en reas bien ventiladas libres de gasolina u otras emanaciones combustibles Si el compresor ser utilizado para utilizar un rociador NO lo coloque en las cercan as de la zona de rociado 40 SP MANTENIMIENTO Responsabilidades del cliente o luego de cada uso 1 Mas frecuente en condiciones polvorientas o humedas Operacion Insegura La unidad arranca automaticamente cuando esta enchufada Al hacer el mantenimiento el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles Antes de intentar hacer reparaciones desconectar el compresor del tomacorriente drenar la presion de aire del tanque y esperar a que el compresor se enfrie Para asegu
12. tubo de salida cuando el compresor de aire alcanza la presi n de corte o es apagado La v lvula aliviadora de presi n permite el arranque libre del motor Cuando el motor se detiene deber a escucharse el escape del aire a trav s de dicha v lvula du rante unos segundos No debe escucharse escape alguno mientras el motor est en marcha ni p rdidas continuas una vez que se alcanz la presi n de corte V lvula aliviadora de presi n 39 SP Protecci n para sobrecarga del motor El motor tiene un reposicionador t rmico por sobrecarga del motor Si el motor se sobre calentase por cualquier raz n el protector de sobrecarga desconectar al motor El motor deber ser dejado enfriar antes de volver a ponerlo en marcha El compresor volver a arrancar autom ticamente una vez enfriado el motor C mo utilizar su unidad C mo detenerla 1 Coloque la posici n de la llave interruptora On Auto Off en la posici n OFF Antes de poner en marcha NET Riesgo de Operaci n Insegura Si las siguientes instrucciones no fuesen seguidas estrictamente podran ocurrir serios danos Este procedimiento es necesario antes de poner en servicio al compresor de aire y cuando la valvula reguladora o la bomba completa del compresor haya sido reemplazada 1 Aseg rese que la palanca On Auto Off est en la posici n OFF NOTA Tire del acoplamiento hacia atr s hasta percibir el clic que impide el escape de
13. 17893 NOTES NOTAS A17893 50 SP Master Protection Agreements Congratulations on making a smart purchase Your new Craftsman product is designed and manufactured for years of dependable operation But like all products it may require preventive maintenance or repair from time to time That s when having a Master Protection Agreement can save you money and aggrava tion Purchase a Master Protection Agreement now and protect yourself from unexpected hassle and expense The Master Protection Agreement also helps extend the life of your new product Here s what s included in the Agreement M Expert service by our 12 000 professional repair specialists MI Unlimited service and no charge for parts and labor on all covered repairs M No lemon guarantee replacement of your covered product if four or more product failures occur within twelve months M Product replacement if your covered product can t be fixed Y Annual Preventive Maintenance Check at your request no extra charge M Fast help by phone phone support from a Sears technician on products requiring in home repair plus convenient repair scheduling M Power surge protection against electrical damage due to power fluctuations M Rental reimbursement if repair of your covered product takes longer than promised Once you purchase the Agreement a simple phone call is all that it takes for you to schedule service You can call anytime day or night or sche
14. For replacement parts contact www allpartsinc com 1 877 475 5660 Owner s Manual CRAFTSMAN Permanently Lubricated Single Stage Portable AIR COMPRESSOR Model No 919 167281 e Safety Guidelines e Assembly e Operation e Maintenance e Service and Adjustments e Troubleshooting e Repair Parts CAUTION Read the Safety Guidelines and All Instructions Carefully Before Oper ating Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman A17893 Rev o 3 20 07 For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 TABLE OF CONTENTS WARRANTY manwananwa wama nwa 2 SPECIFICATIONCHART 3 SAFETYGUIDELINES 3 8 GLOSSARY wamamamamwan 9 ACCESSORIES 9 DUTYCYCLE 9 ASSEMBLY oauan aana nananana naaa aaa aaa 10 INSTALLATION 11 13 OPERATION oaoa aaa aaa aaaea 14 16 MAINTENANCE 17 20 SERVICE AND ADJUSTMENTS 21 22 STORAGE eee 22 TROUBLESHOOTING GUIDE 23 26 REPAIR PARTS 28 31 ESPANOL
15. Pull the Knob out and turn clockwise to increase pressure and counter clockwise to decrease pressure When the desired pressure is reached push knob in to lock in place Drain Valve The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use Cooling System not shown This compressor contains an advanced design cooling system At the heart of this cooling system is an engineered fan It is perfectly normal for this fan to blow air through the vent holes in large amounts You know that the cooling system is working when air is being expelled 12 ENG 1 877 475 5660 For replacement parts contact For replacement parts contact Air Compressor Pump not shown Compresses air into the air tank Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet Check Valve When the air compres sor is operating the check valve is open allowing compressed air to enter the air tank When the air com pressor reaches cut out pressure the check valve closes allowing air pressure to remain inside the air tank Pressure Release Valve The pres sure release valve located on the side of the pressure switch is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches cut out pressure or is shut off The pressure release valve allows
16. YOUR UNIT Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments Save this manual for future reference Pressure Switch On Auto Off Switch Description of Operation Become familiar with these controls before operating the unit On Auto Off Switch Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use Pressure Switch The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pressure It stops the motor when the air tank pressure reaches the factory set cut out pres sure Safety Valve If the pressure switch does not shut off the air compressor at its cut out pressure setting the safety valve will protect against high pressure by popping out at its fac tory set pressure slightly higher than the pressure switch cut out setting Outlet Pressure Gauge The outlet pressure gauge indicates the air pres sure available at the outlet side of the regulator This pressure is controlled by the regulator and is always less than or equal to the tank pressure Tank Pressure Gauge The tank A17893 For replacement parts contact Tank Pressure Gauge www allpartsinc com Outlet Pressure pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge
17. a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the product e in good condition e no longer than 50 feet e 12 gauge AWG or larger Wire size increases aS gauge number decreases 10 AWG and 8 AWG may also be used DO NOT USE 14 OR 16 AWG 11 ENG www allpartsinc com www allpartsinc com Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with specifications 4 Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse NOTE If compressor is connected to a circuit protected by fuses use only time delay fuses Time delay fuses should be marked D in Canada and T in the US If any of the above conditions cannot be met or if operation of the com pressor repeatedly causes interrup tion of the power it may be necessary to operate it from a 20 amp circuit It is not necessary to change the cord set A CAUTION A17893 1 877 475 5660 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 OPERATION Know Your Air Compressor READ THIS OWNER S MANUAL AND SAFETY RULES BEFORE OPERATING
18. a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances A17893 www allpartsinc com 2 Make sure the outlet being used has the same configuration as the grounded plug DO NOT USE AN ADAPTER See illustration NE Grounding Pin 3 Inspect the plug and cord before each use Do not use if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qualified electrician a Risk of Electrical Shock IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK Do not modify the plug provided If it does not fit the available outlet a correct outlet should be installed by a qualified electrician Repairs to the cord set or plug MUST be made by a qualified elec trician 10 ENG 1 877 475 5660 1 877 475 5660 For replacement parts contact For replacement parts contact Extension Cords Using extension cords is not recom mended The use of extension cords will cause voltage to drop resulting in power loss to the motor and over heating Instead of using an extension cord increase the working reach of the air hose by attaching another length of hose to its end Attach additional lengths of hose as needed If an extension cord must be used be sure it is e a3 wire extension cord that has
19. a la madera Su riesgo a esas exposiciones variar dependiendo de la frecuencia con la que usted realice diferentes tipos de trabajo Para reducir su exposici n a la acci n de dichos agentes qu micos Trabaje en zonas bien ventiladas y h galo con equipo de seguridad aprobado use siempre protecci n facial o respirador aprobado por MSHA NIOSH cuando opere esas herramientas Al utilizar herramientas neum ticas tambi n deben tomarse precauciones b sicas de seguridad a fin de reducir la posibilidad de riesgo de lesiones personales 29 SP A17893 INSTRUCCIONES IMPORTANTES DE SEGURIDAD La operacion o el mantenimiento inadecuados de este producto podrian ocasionar lesiones serias y da os a la propiedad Lea y comprenda todas las advertencias e instrucciones de funcionamiento antes de utilizar este equipo ADVERTENCIA Riesgo de Explosion o Incendio Qu puede occurrir Es normal que los contactos el ctricos del motor y del interruptor de presi n emitan chispas Si las chispas el ctricas provenientes del compresor tomaran contacto con emanaciones de materiales inflamables ellos podr an arder originando incendio o explosi n Restringir cualquiera de las aberturas de ventilaci n causar un serio recalentamiento y podr a producir un incendio Dejar desatenida esta unidad mientras est en funcionamiento puede causar lesiones personales o da os a la propiedad Para reducir el riesgo de incendio no permi
20. ase pressure When the desired pressure is reached push knob in to lock in place The compressor is ready for use NOTE Always operate the air com pressor in well ventilated areas free of gasoline or other combustible vapors If the compressor is being used to operate a sprayer DO NOT place near the spray area A17893 14 ENG www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 MAINTENANCE Customer Responsibilities Daily or after Every Every 40 hours hours 1 more frequent in dusty or humid conditions Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconnect electrical supply to the air compressor bleed tank of pressure and allow the air compressor to cool AWARNING To ensure efficient operation and lon ger life of the air compressor a rou tine maintenance schedule should be prepared and followed The following routine maintenance schedule is geared to a unit in a normal working environment operating on a daily ba sis If necessary the schedule should be modified to suit the conditions under which your compressor is used The modifications will depend upon the hours of operation and the work ing environment Compressor units in an extremely dirty and or hostile environment will require a
21. bel 45 LA 3069 Label Craftsman 46 LA 3027 Label Drain Tank 47 LA 3108 Label Hot Surface 48 SST 5314 1 Recess Rubber Bumper 50 A17405 Label 51 D23138 Wheel 52 CAC 60 Bolt 53 SSF 8080 ZN Nut 54 D23563 Label Performance y NOTES 1 Torque to 15 25 in lbs 3 Torque to 9 12 ft lbs 28 Torque to 5 7 ft lbs 34 Torque to 100 120 in lbs For replacement parts contact 25 ENG www allpartsinc com QTY NNN Nm mn D LB S S S AO NN B CO A17893 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 PUMP DIAGRAM Air Compressor Model Number 919 167281 PARTS SHOWN FOR REFERENCE ONLY A17893 26 ENG For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 PARTS LIST Air Compressor Model Number 919 167281 ITEM PART NO 70 72 73 74 88 856 856 876 876 876 876 876 NO SSF 586 AC 0108 SSF 615 Z AC 0140 Z D26712 ACG 29 K 0650 SSG 8156 Z AC 0032 CAC 1371 ACG 45 AC 0037 SSF 927 KK 4835 CAC 248 2 SSF 3158 1 A09924 D20597 D21477 D23936 D29142 D29185 D30107 6 NOTES 10 73 19 89 88 DESCRIPTION Screw Fan Screw Eccentric Bearing Motor Connecting Rod Cap Compression Ring Kit O ring Valve Plate Assembly Muffler O ring Head Screw Connecting Rod Kit Compression Ring Screw Accessory Kit 13 piece
22. c feet per which the motor automatically restarts minute a unit of measure of air is called cut in pressure delivery Cut Out Pressure When an air PSIG Pounds per square inch compressor is turned on and begins gauge a unit of measure of pressure to run air pressure in the air tank KANGA Aes begins to build It builds to a certain Code Certification Products that high pressure before the motor bear one or more of the following automatically shuts off protecting WA ied oo ui your air tank from pressure higher l than its capacity The high pressure independent safety laboratories and at which the motor shuts off is called meet the applicable Underwriters Laboratories Standards for Safety cut out pressure ji Branch Circuit Circuit carrying Cut In Pressure While the motor electricity from electrical panel to is off air tank pressure drops as outlet you continue to use your accessory This unit is capable of powering the following Accessories The accessories are available through the current Power and Hand Tool Catalog or full line Sears stores Accessories e Air Pressure Regulators e In Line Filter e Oil Fog Lubricators e Tire Air Chuck e Air Hose 1 4 3 8 or 1 2 1 D in e Quick Connector Sets various various lengths sizes Refer to the selection chart located on the unit to select the tools this unit is capable of powering DUTY CYCLE This air compressor pump is that a 50 75 average duty
23. can result oil leaks will damage carpet paint or other surfaces in vehicles or trailers How To Prevent It Always place COMPRESSOR ona protective mat when transporting to protect against damage to vehicle from leaks Remove COMPRESSOR from vehicle immediately upon arrival at your destination HAZARD WARNING Risk of Unsafe Operation What Could Happen Unsafe operation of your air compressor could lead to serious injury or death to you or others EN Review and understand all instructions and warnings in this manual Become familiar with the operation and controls of the air compressor Keep operating area clear of all persons pets and obstacles Keep children away from the air compressor at all times Do not operate the product when fatigued or under the influence of alcohol or drugs Stay alert at all times Never defeat the safety features of this product Equip area of operation with a fire extinguisher Do not operate machine with missing broken or unauthorized parts How To Prevent It SAVE THESE INSTRUCTIONS A17893 For replacement parts contact www allpartsinc com 8 ENG 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 GLOSSARY Become familiar with these terms When the tank pressure drops to a before operating the unit certain low level the motor will restart CFM Cubic feet per minute automatically The low pressure at SCFM Standard cubi
24. ces Compressor is not large sories enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air intake filter Regulator knob Damaged regulator has continuous air leak 21 ENG CORRECTION If there is an excessive amount of pressure drop when the accessory is used adjust the regulator follow ing the instructions in the Description of Operation paragraph in the Operation Section NOTE Adjust the regulated pressure under flow conditions while accessory is being used Operate safety valve manually by pulling on ring If valve still leaks it should be replaced Remove and clean or replace Decrease amount of air us age Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace if required Remove and clean or replace Tighten fittings Clean or replace air intake filter Do not operate the air compressor with the filter removed Refer to the Air Filter paragraph in the Maintenance section Replace A17893 For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact PROBLEM Regulator will not shut off air outlet Motor will not run A17893 For replacement parts contact CAUSE Damaged regulator Motor overload protection switch has tripped Tank pressure exceeds pres sure swi
25. cista competente 36 SP Cables de extension el ctrica No se recomienda la utilizaci n de cables de extensi n el ctrica El uso de cables de extensi n el ctrica originar una ca da de tensi n lo que determinar una p rdida de potencia del motor as como su recalentamiento En lugar de utilizar un cable de extensi n el ctrica incremente el alcance de la manguera de aire dentro de la zona de trabajo a adi ndole otro largo de manguera a su extremo Conecte los largos adicionales de manguera de acuerdo a su necesidad Si no obstante debe utilizarse una extensi n de cable aseg rese de que La extensi n el ctrica de 3 conductores tenga un enchufe de conexi n a tierra de 3 hojas y que exista un recept culo que acepte el enchufe del producto e Est en buenas condiciones No m s largo que 15 2 m 50 pies e Calibre 12 AWG o mayor La medida de los cables se incrementa a medida que su n mero ordinal decrece 10 y 8 AWG pueden ser usados tambi n NO USE 14 NI 16 AWG 37 SP Protecci n del voltaje y del circuito Acerca del voltaje y la m nima cantidad de circuitos requeridos refi rase al cuadro de especificaciones APRECAUCI N Riesgo de Operaci n Lasegura Ciertos compresores de aire pueden ser operados en un circuito de 15 A siempre que se cumplan las siguientes condiciones 1 Que el voltaje suministrado a trav s de los ramales del circuito sea de 15 A 2 Que el c
26. d result in serious injury How To Prevent It Drain tank daily or after each use If tank develops a leak replace it immediately with a new tank or replace the entire compressor Never drill into weld or make any modifications to the tank or its attachments The tank is designed to withstand specific operating pressures Never make adjustments or parts substitutions to alter the factory set operating pressures For essential control of air pressure you must install a pressure regulator and pressure gauge to the air outlet if not equipped of your compressor Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments Never use compressor to inflate small low pressure objects such as children s toys footballs basketballs etc HAZARD WARNING Risk from Flying Objects What Could Happen The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt chips loose particles and small objects at high speed resulting in property damage or personal injury 5 ENG For replacement parts contact www allpartsinc com How To Prevent It Always wear ANSI Z87 1 approved safety glasses with side shields when using the compressor Never point any nozzle or sprayer toward any part of the body or at other people or animals Always turn the compressor off and bleed pressure from the air hose and tank before attemptin
27. da os a la propiedad o lesiones personales A17893 C mo prevenirlo Al utilizar el compresor use siempre anteojos de seguridad con protecci n lateral aprobados seg n la norma 287 1 de ANSI Jam s apunte boquilla o pulverizador alguno hacia partes del cuerpo a otras personas o animales Siempre apague el compresor y purgue la presi n de la manguera de aire y del tanque antes de intentar el mantenimiento el acople de herramientas o accesorios 32 SP ADVERTENCIA Riesgo de Quemaduras Qu puede occurrir C mo prevenirlo Tocar el metal expuesto tal como el cabezal Jam s toque partes de metal expuestas en el del compresor o los tubos de salida del escape compresor durante o inmediatamente despu s puede ocasionarle quemaduras serias de la operaci n El compresor permanecer caliente por varios minutos luego de la operaci n No burle las cubiertas protectoras o intente el mantenimiento hasta que la unidad se enfr e as Y C mo prevenirlo ADVERTENCIA Riesgo de Partes M viles Qu puede occurrir Partes movibles tales como la polea el volante Nunca opere el compresor sin sus cubiertas o y la correa podr an ser la causa de lesiones si estuviesen da adas serias usted ci o su ropa entran en contacto con ellas Intentar operar el compresor con piezas Cualquier reparaci n requerida por esta unidad da adas o faltantes o repararlo sin sus debe hacerla el personal de u
28. dado abierta Conexiones el ctricas sueltas Compruebe la conexi n de cablea do dentro del interruptor de presi n y del rea de la caja de terminales Posible motor o capacitor de Haga inspeccionar por un t cnico arranque defectuosos capacitado de servicio Rociado de pintura en las par Haga inspeccionar por un t cnico tes internas del motor capacitado de servicio No haga funcionar el compresor en el rea de pintura por rociado Vea la adverten Cia acerca de vapores inflamables La v lvula de liberaci n de Purgue la linea empujando la presi n en el interruptor de palanca en el interruptor de presi n presi n no ha descargado la a la posici n OFF Apagado si carga de presi n la v lvula no se abre reemplace el interruptor Fusible quemado disyuntor 1 Inspeccione la caja de fusibles abierto para determinar si hay fusibles quemados y reempl celos seg n sea necesario Reajuste el disyuntor No use un fusible o disyuntor con capacidad mayor que la especificada para su circuito especificado 2 Compruebe si el fusible es el correcto Debe usar un fusible de acci n retardada 3 Compruebe si existen condiciones de bajo voltaje y o si el cord n de extensi n es el correcto 4 Desconecte todos los otros artefactos el ctricos del circuito u opere el compresor en su propio circuito A17893 48 SP For replacement parts contact www allpartsinc com 1 877 475 5660 NOTES NOTAS 49 SP A
29. de puertas de garajes calentadores de agua y otros artefactos grandes del hogar en EE UU llame al 1 800 4 MY HOME A17893 Get it fixed at your home or ours Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owners manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Anytime day or night 1 800 469 4663 U S A and Canada www sears com www sears ca Our Home For repair of carry in products like vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts and Repair Center 1 800 488 1222 Anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparaci n Au Canada pour service en fran ais a domicilio y para ordenar piezas 1 800 LE FOYER C 1 888 SU HOGAR 1 800 533 6937 1 888 784 6427 WWW sears ca SEARS Sears Roebuck and Co O Registered Trademark Trademark SM Service Mark of Sears Roebuck and Co O Marca Registrada Marca de F brica SM Marca de Servicio de Sears Roebuck and Co MC Marque de c
30. dule a service appointment online Sears has over 12 000 professional repair specialists who have access to over 4 5 million quality parts and accessories That s the kind of professionalism you can count on to help prolong the life of your new purchase for years to come Purchase your Master Protection Agreement today Some limitations and exclusions apply For prices and additional information call 1 800 827 6655 Sears Installation Service For Sears professional installation of home appliances garage door openers water heat ers and other major home items in the U S A call 1 800 4 MY HOME 51 SP Contratos de Protecci n Maestra Felicitaciones por hacer una compra inteligente Su nueva unidad Craftsman esta dise ada y fabricada para a os de operaci n confiable pero como todos los productos de calidad podr a requirir reparaciones de vez en cuando Ah es cuando el Contrato de Protecci n Maestra le puede ahorrar dinero y molestias Compre ahora un Contrato de Protecci n Maestra y prot jase contra apuros y gastos inesperados El Contrato de Protecci n Maestra tambi n permite prolongar la vida til de su nueva unidad Este contrato incluye lo siguiente M Servicio Experto a cargo de uno de nuestros 12 000 profesionales especializados en reparaciones M Servicio ilimitado sin cargo por repuestos y mano de obra en todas las reparaciones cubiertas MI Garant a por defectos de f brica cubre
31. e presi n permite el arranque autom tico del motor cuando la presi n del tanque disminuye por debajo del valor de la presi n de conexi n regulada en f brica El motor se detendr cuando la presi n del tanque alcance los valores de presi n de corte regulado en f brica para su desconexi n V lvula de seguridad Si el interruptor de presi n dejara de cortar el suministro de pre si n del compresor conforme a los valores prefijados para la presi n de corte la v lvula de seguridad proteger contra la presi n elevada saltando de acuerdo a los valores prefijados en f brica ligeramente superiores a los de presi n de corte de la llave inter ruptora Man metro para controlar la presi n de salida Este man metro indicar la presi n de aire disponible a la salida del regulador Esta presi n est controlada por el regulador y es siempre menor o igual que la presi n del tanque A17893 3 Manometro de J presi n del tangue a Man metro de presion de salida Man metro de la presi n del tanque El man metro que controla la presi n del tanque indica la reserva de presi n del tanque de aire Regulador Controla la presi n de aire mostrada en el man metro de salida Tire de la perilla y g rela en sentido horario para incrementar la presi n y h galo en sentido inverso para disminuirla Cuando se logre la presi n deseada presione la perilla para bloquearla V lvula de drenaje La v lvu
32. e usted contin a usando su accesorio Cuando la presi n del tanque baja al valor fijado en f brica como punto bajo el motor volver a ar rancar autom ticamente La presi n baja a la cual el motor arranca autom ticamente se llama presi n m nima de corte Presi n m xima de corte Cuando un compresor de aire se enciende y comienza a funcionar la presi n de aire en el tanque comienza a aumentar Aumenta hasta un valor de presi n alto fijado en f brica antes de que el motor autom tica mente se apague protegiendo a su tanque de aire de presiones m s altas que su capacidad La presi n alta a la cual el mo tor se apaga se llama presi n m xima de corte Ramal Circuito el ctrico que transporta electricidad desde el panel de control hasta el tomacorriente ACCESORIOS Esta unidad es suficiente para abastecer de energia el ctrica a los siguientes accesorios Estos se encuentran disponibles a trav s del catalogo para herramientas el ctricas y manuales en cualqui era de los comercios que mantiene la linea completa de SEARS e Reguladores de presion de aire e Lubricadores de niebla de aceite e Manguera de aire 1 4 plug 3 8 plug 1 2 plug D I en varias medidas Accesorios e Filtro en linea e Entrada de aire a neumaticos e Juegos de conectores rapidos varios tama os Refi rase al grafico de selecci n ubicado sobre la unidad para elegir el tipo de herramienta que esta unidad es capaz de hacer
33. eaks at fit Tube fittings are not tight Tighten fittings where air can tings enough be heard escaping Check fittings with soapy water so lution Do Not Overtighten Air leaks at or Check valve seat damaged A defective check valve inside check results in a constant air leak valve at the pressure release valve when there is pressure in the tank and the compressor is shut off Replace check valve Refer to the To Re place or Clean Check Valve in the Service and Adjust ment section Air leaks at Defective pressure switch Contact a Trained Service pressure switch release valve Technician release valve Air leaks in air Defective air tank Air tank must be replaced tank or at air Do not repair the leak tank welds AWARNING Risk of Bursting Do not drill into weld or otherwise modify air tank or it will weaken The tank can rupture or explode Air leaks be Leaking seal Contact a Trained Service tween head and Technician valve plate A17893 20 ENG For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 PROBLEM CAUSE Pressure reading t is normal for some on the regulated pressure drop to occur pressure gauge drops when an accessory is used Knocking Noise Possible defect in safety valve Defective check valve Compressor is Prolonged excessive use of not supplying air enough air to operate ac
34. eder la presi n especificada para las herramientas neum ticas pistolas rociadoras accesorios activados por aire llantas neum ticas y otros objetos inflables puede causar su explosi n o que salgan disparados pudiendo ocasionar lesiones serias C mo prevenirlo Drene el tanque diariamente o despu s de cada uso Si el tanque genera una p rdida reempl celo inmediatamente con un nuevo tanque o reemplace el compresor completo Jam s perfore suelde o efect e modificaci n alguna al tanque o sus accesorios El tanque est dise ado para resistir presiones operativas espec ficas Jam s efect e ajustes o sustituya partes que alteren las regulaciones de presi n originales de f brica Para un control preciso de la presi n debe usted instalar un regulador y un medidor de presi n a la salida del aire de su compresor Si no estuviese equipado Siga las recomendaciones de los fabricantes de su equipo y jam s exceda los valores m ximos de presi n permitidos para los accesorios Jam s use el compresor para inflar objetos que requieren poca o baja presi n tales como juguetes para los ni os pelotas de f tbol pelotas de b squet etc ADVERTENCIA Riesgo de Objetos Arrojados por el Aire Qu puede occurrir El chorro de aire comprimido puede causar lesiones a los tejidos blandos de la piel expuesta y puede propulsar suciedad astillas part culas sueltas y peque os objetos a alta velocidad ocasionando
35. el reemplazo de su unidad si dentro de los doce meses ocurren cuatro o m s fallas M Reemplazo de la unidad si su unidad cubierta no puede repararse M Control Anual de Mantenimiento Preventivo a su solicitud sin cargo adicional M Asistencia telef nica r pida a cargo de personal t cnico de soporte de Sears para las unidades que requieran repararse en su domicilio en horarios convenientes para usted M Protecci n contra los da os ocasionados por sobretensi n transitoria debido a fluctuaciones de energ a M Reembolso de alquiler si la reparaci n de su unidad cubierta lleva m s tiempo del prometido Una vez que usted compre su Contrato s lo necesita hacer una simple llamada telef nica para programar su servicio Puede llamar a cualquier hora del d a o la noche o puede programar su servicio en l nea v a Internet Sears tiene m s de 12 000 profesionales especializados en reparaciones que tienen acceso a m s 4 5 millones de repuestos y accesorios de calidad Ese es el tipo de profesionalismo con el cual usted puede contar que le ayudar a prologar la vida til de su unidad durante todos los a os por venir Compre hoy su Contrato de Protecci n Maestra Se aplican algunas limitaciones y exclusiones Para precios e informaci n adicional llame al 1 800 827 6655 Servicio de Instalaciones de Sears Para instalaciones profesionales de artefactos para el hogar a cargo de Sears como abridores
36. f tank 19 ENG For replacement parts contact www allpartsinc com NTN Ne Risk of Bursting Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture and possible serious personal injury 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned and reinstalled 8 Protect the electrical cord and air hose from damage Such as being stepped on or run over Wind them loosely around the compressor handle If so equipped 9 Store the air compressor in a clean and dry location A17893 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 TROUBLESHOOTING INVIN Title Risk of Unsafer Operation Performing repairs may expose voltage sources moving parts or compressed air sources Personal injury may occur Before servicing Unplug or disconnect electrical supply to the air compressor bleed tank of pressure and allow the air compressor to cool PROBLEM CAUSE CORRECTION Excessive tank Pressure switch does not Move On Auto Off lever to pressure safety shut off motor when the OFF position if the unit valve pops off compressor reaches does not shut off contact a cut out pressure Trained Service Technician Contact a Trained Service Pressure switch cut out Technician too high Air l
37. funcionar CICLO DE SERVICIO de servicio que oscile entre el 50 y el 75 ello significa que la bomba compresora no deberia trabajar mas de 30 a 45 minutos por hora Esta bomba compresora de aire es capaz de funcionar continuamente sin embargo para prolongar la vida util de su compresor de aire se recomienda mantener un ciclo promedio 35 SP A17893 ENSAMBLADO Desempaque 1 Extraiga la unidad de su caja y descarte todas las partes de embalaje INSTALACI N C MO PREPARAR LA UNIDAD Ubicaci n del compresor de aire Ubique al compresor de aire en una zona limpia seca y bien ventilada La bomba del compresor de aire y su carcasa han sido dise adas para permitir un enfria miento adecuado Las aberturas de venti laci n del compresor resultan entonces necesarias para el mantenimiento de una adecuada temperatura de funcionamiento No coloque g neros o contenedores encima ni en las proximidades de dichas aberturas E filtro de aire debe manten erse libre de obstrucciones que podr an reducir el flujo de aire al compresor INSTRUCCIONES PARA CONECTAR A TIERRA Mc 0 Riesgo de Descarga El ctrica Ante la eventualidad de un cortocircuito la conexi n a tierra reduce el riesgo de electrocuci n proveyendo un conductor de escape para la corriente el ctrica Este compresor de aire debe estar adecuadamente conectado a tierra El compresor port til de aire est equi pado con un cable que tiene
38. g maintenance attaching tools or accessories A17893 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 HAZARD WARNING Risk of Electrical Shock What Could Happen Your air compressor is powered by electricity Like any other electrically powered device If it is not used properly it may cause electric shock Repairs attempted by unqualified personnel can result in serious injury or death by electrocution Electrical Grounding Failure to provide adequate grounding to this product could result in serious injury or death from electrocution See grounding instructions How To Prevent It Never operate the compressor outdoors when it is raining or in wet conditions Never operate compressor with protective covers removed or damaged Any electrical wiring or repairs required on this product should be performed by authorized service center personnel in accordance with national and local electrical codes Make certain that the electrical circuit to which the compressor is connected provides proper electrical grounding correct voltage and adequate fuse protection HAZARD WARNING Risk to Breathing What Could Happen The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials
39. greater frequency of all maintenance checks NOTE See Operation section for the location of controls 15 ENG For replacement parts contact www allpartsinc com To Check Safety Valve INN NTE Risk of Bursting If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion 1 Before starting compres sor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF and unplug unit 2 Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 5 Drain water from air tank by opening drain valve counter clockwise on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture A17893 1 877 475 5660 For replacement parts contact 6 After the water has been drained close the drain valve clockwise The air compressor can now be stored NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned the reinstalled Air Filter Inspection and
40. intento de reparaciones al tanque Modificaciones no autorizadas a la v lvula de descarga v lvula de seguridad o cualquier otro componente que controle la presi n del tanque La vibraci n excesiva puede debilitar el tanque de aire y causar su ruptura o explosi n ADITAMENTOS Y ACCESORIOS Exceder la presi n especificada para las herramientas neum ticas pistolas rociadoras accesorios activados por aire llantas neum ticas y otros objetos inflables puede causar su explosi n o que salgan disparados pudiendo ocasionar lesiones serias C mo prevenirlo Drene el tanque diariamente o despu s de cada uso Si el tanque genera una p rdida reempl celo inmediatamente con un nuevo tanque o reemplace el compresor completo Jam s perfore suelde o efect e modificaci n alguna al tanque o sus accesorios El tanque est dise ado para resistir presiones operativas espec ficas Jam s efect e ajustes o sustituya partes que alteren las regulaciones de presi n originales de f brica Para un control preciso de la presi n debe usted instalar un regulador y un medidor de presi n a la salida del aire de su compresor Si no estuviese equipado Siga las recomendaciones de los fabricantes de su equipo y jam s exceda los valores m ximos de presi n permitidos para los accesorios Jam s use el compresor para inflar objetos que requieren poca o baja presi n tales como juguetes para los ni os pelotas de f tbol pe
41. ircuito no sea utilizado para alimentar ninguna otra necesidad el ctrica 3 Que los cables de extensi n cumplan con las especificaciones 4 El circuito cuenta con un disyuntor de 15 amperios o un fusible de acci n retardada de 15 amperios NOTA Si el compresor est conectado a un circuito protegido por fusibles use s lo fusibles de acci n retardada Los fusibles de acci n retardada deben estar marcados con la letra D en Canad y T en EE UU Si cualquiera de las condiciones enu meradas no pudiese ser cumplida o si el funcionamiento del compresor causara reiteradas interrupciones de la energ a con la que se lo alimenta podr a ser necesario operar al mismo desde un circuito de 20 A Para ello no ser necesario cambiar su cable de limentaci n A17893 OPERACI N Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci n de los distintos controles y regulaciones Conserve este manual para referencias futuras o Interruptor de presi n Descripci n de operaciones Familiaricese con estos controles antes de operar la unidad Interruptor On Auto Off Mueva este inter ruptor a la posici n ON para dar contacto autom tico al interruptor de presi n y OFF para interrumpir la energ a el ctrica al t rmino del uso Interruptor de presi n El interruptor d
42. juste Contacte a un t cnico calificado en servicio El tanque de aire debe ser reem plazado No repare la perdida ADVERTENCIA ha Explosi n No perfore suelde ni modifique el tanque en forma alguna porque se debilitar Contacte a un t cnico calificado en servicio 1 877 475 5660 For replacement parts contact La lectura de la presi n sobre un manometro si vi ene equipado con ste desciende cuando se utiliza un accesorio Golpeteo El compresor no esta suminist rando suficiente cantidad de aire para operar los ac cesorios El regulador tiene una fuga continua de aire El regulador no cierra la salida del aire For replacement parts contact Posible defecto en la v lvula de seguridad Posible defecto en la v lvula de seguridad Excesivo y prolongado uso del aire El compresor no tiene su ficiente capacidad para el requerimiento de aire al que est sometido Orificio en la manguera V lvula reguladora restringida P rdida de aire Filtro de entrada de aire re stringido Regulador da ado Regulador da ado 47 SP www allpartsinc com PROBLEMA CAUSA Es normal que ocurra alg n descenso en la presi n www allpartsinc com 1 877 475 5660 CORRECCION Si hubiese una caida excesiva de presi n durante el uso del acceso rio ajuste el regulador de acuerdo a las instrucciones de la secci n Operaci n NOTA Ajuste la presi n
43. l compresor alcanza la presi n de corte PROBLEMA Presi n excesiva del tanque la v l vula de seguridad se dispara El interruptor de presi n de corte esta calibrado demasiado alto Las conexiones Las conexiones de los tubos no pierden aire Compruebe si el asiento de la v lvula est da ado Hay fugas de aire en la v lvula de retenci n o dentro de ella Un interruptor de presi n defec tuoso libera la v lvula P rdida de presi n de aire en el interruptor de la v lvula aliviadora P rdida de aire en Tanque de aire defectuoso el tanque de aire o en las soldaduras del tanque de aire P rdida en el sellado P rdida de aire entre el cabezal y el plato de v lvula A17893 46 SP est n suficientemente ajustadas www allpartsinc com CORRECCI N Mueva la palanca On Auto Off a la posici n OFF si el equipo no corta contacte a un t cnico calificado para el servicio Contacte a un t cnico de servicio calificado Ajuste las conexiones en las que el aire puede ser escuchado escap ndose Verifique las con exiones con soluci n jabonosa y agua NO SOBREAJUSTE Una v lvula de retenci n defec tuosa causa una fuga constante de aire en la v lvula de alivio de presi n cuando hay presi n en el tanque y se apaga el com presor Reemplace la v lvula de retenci n Consulte C mo Re emplazar o Limpiar la V lvula de Retenci n en la secci n Servico y ad
44. l aire de la conexi n r pida 2 Enchufe el cable de alimentaci n en el recept culo del ramal del circuito correcto Referirse al p rrafo Protecci n del voltaje y del circuito en la secci n Instalaci n de este manual 3 Abra completamente la v lvula de drenaje sentido antihorario a fin de permitir la salida del aire e impedir el aumento de la presi n dentro del tanque de aire durante el periodo de asentamiento A17893 Mueva la palanca On Auto Off a la posicion ON AUTO El compresor se pondra en marcha Haga funcionar el compresor durante 15 minutos Asegurese de que la valvula de drenaje est abierta y que la presi n de aire acumulado en el tanque sea minima Luego de 15 minutos cierre la valvula de drenaje sentido horario El aire recibido ira llenando hasta el punto de corte de presi n y el motor se detendra El compresor estara ahora listo para ser usado Antes de cada puesta en marcha 1 Coloque el interruptor On Auto Off en la posici n OFF y cierre el regulador de aire 2 Tire de la perilla del regulador gire en sentido antihorario hasta el l mite Empuje la perilla hasta su posici n blocante 3 Conecte la manguera y accesorios NOTA Tanto la manguera como los accesorios requerir n un enchufe de conexi n r pida si la salida del aire est equipada con un z calo de conexi n r pida NOTE Riesgo de Explosion Demasiada presion de aire podra ser la causa de
45. la de drenaje se encuentra ubicada sobre la base del tanque de aire y se usa para drenar la condensaci n al fin de cada uso V lvula de drenajea Sistema de enfriamiento no mostrado Este compresor contiene un sistema de avanzada para el control de enfriamiento En el n cleo de este sistema de enfriamiento hay un ventilador especialmente dise ado Resulta perfectamente normal para este ventilador soplar aire en grandes canti dades a trav s de los orificios de ventilaci n De tal manera se podr saber que el sistema de enfriamiento trabaja cuando el aire esta siendo expelido 38 SP Bomba de compresi n del aire no mostrada Comprime el aire dentro del tanque El aire de trabajo no se encuentra disponible hasta que el compresor haya alcanzado a llenar el tanque hasta un nivel de presi n por encima del requerido para la salida del aire Valvula reguladora Cuando el compresor de aire se encuentra funcionando la valvula reguladora esta abierta permitiendo la entrada del aire comprimido al tanque de aire Cuando el nivel de presi n del tanque alcanza el punto de corte la valvula regu ladora se cierra reteniendo la presi n del aire dentro del tanque V lvula reguladora V lvula aliviadora de presi n La v lvula aliviadora de presi n se encuentra ubicada en el costado del interruptor de presi n ha sido dise ada para liberar autom ticamente el aire comprimido de la cabeza compresora y el
46. lotas de b squet etc ADVERTENCIA Riesgo de Objetos Arrojados por el Aire Qu puede occurrir El chorro de aire comprimido puede causar lesiones a los tejidos blandos de la piel expuesta y puede propulsar suciedad astillas part culas sueltas y peque os objetos a alta velocidad ocasionando da os a la propiedad o lesiones personales 31 SP C mo prevenirlo Al utilizar el compresor use siempre anteojos de seguridad con protecci n lateral aprobados seg n la norma 287 1 de ANSI Jam s apunte boquilla o pulverizador alguno hacia partes del cuerpo a otras personas o animales Siempre apague el compresor y purgue la presi n de la manguera de aire y del tanque antes de intentar el mantenimiento el acople de herramientas o accesorios A17893 ADVERTENCIA Riesgo de Explosion Tanque de aire las siguientes condiciones podr an causar el debilitamiento del tanque y causar su explosi n violenta da os a la propiedad o lesiones serias Qu puede occurrir El drenaje inadecuado del agua condensada en el tanque le causa xido que reduce el espesor del tanque de acero Modificaciones o intento de reparaciones al tanque Modificaciones no autorizadas a la v lvula de descarga v lvula de seguridad o cualquier otro componente que controle la presi n del tanque La vibraci n excesiva puede debilitar el tanque de aire y causar su ruptura o explosi n ADITAMENTOS Y ACCESORIOS Exc
47. mask or respirator when using such tools When using air tools basic safety precautions should always be followed to reduce the risk of of personal injury 3 ENG A17893 www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and prop erty damage Read and understand all warnings and operation instructions before using this equipment HAZARD WARNING Risk of explosion or fire What Could Happen It is normal for electrical contacts within the motor and pressure switch to spark If electrical sparks from compressor come into contact with flammable vapors they may ignite causing fire or explosion Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire Unattended operation of this product could result in personal injury or property damage To reduce the risk of fire do not allow the compressor to operate unattended A17893 For replacement parts contact www allpartsinc com M How To Prevent It Always operate the compressor in a well ventilated area free of combustible ma terials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required
48. n servicentro cubiertas puestas puede exponerlo a usted autorizado a piezas en movimiento que le ocacionen lesiones serias ADVERTENCIA Riesgo de Ca da bi Qu puede occurrir C mo prevenirlo Un compresor port til puede caerse de la Siempre opere el compresor en una posici n mesa el banco de trabajo o del techo pudiendo estable y segura a fin de prevenir el movimiento da arse y causar lesiones serias o la muerte accidental de la unidad Jam s opere el del operador compresor sobre un techo u otra posici n elevada Utilice mangueras adicionales de aire para alcanzar posiciones altas 33 SP A17893 ADVERTENCIA Riesgo de Lesiones Serias o Da os a la Propiedad al Transportar el Compresor Fuego inhalaci n da o a la superficie de veh culos Qu puede occurrir C mo prevenirlo El aceite puede derramarse generando un ries go de incendio o inhalaci n que puede causar lesiones serias o muerte El derrame de aceite da a alfombras pinturas u otras superficies de veh culos o remolques Deposite el compresor sobre una alfombrilla protectora cuando lo transporte a fin de proteger el contra los goteos Retire el com presor del veh culo inmediatamente despu s de su arribo al destino ADVERTENCIA Riesgo de Operaci n Insegura Qu puede occurrir La operacion insegura de su compresor de aire podr a ocasionarle lesiones serias o la muerte a usted u otros C mo p
49. nc com 1 877 475 5660 To Replace Regulator 6 Assemble the regulator and 1 Release all air pressure from air orient as shown tank See To Drain Tank in the a Maintenance section 2 Set the On Auto Off lever to OFF and unplug unit 3 Remove the outlet pressure gauge and quick connect if equipped from the regulator NOTE Arrow indicates flow of air Make sure it is pointing in the direction of air flow Regulator _ PY 4 Remove the regulator 5 Apply pipe sealant tape to the nipple 7 Reapply pipe sealant to outlet pressure gauge and quick connect 8 Reassemble outlet pressure gauge and quick connect Orient outlet pressure gauge to read correctly Tighten quick connect with wrench A17893 18 ENG For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 STORAGE Before you store the air compressor make sure you do the following 1 Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary 2 Set the On Auto Off lever to OFF and unplug unit 3 Turn the regulator counterclockwise and set the outlet pressure to zero 4 Remove the air tool or accessory 5 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 6 Drain water from air tank by Opening drain valve on bottom o
50. ng Parts What Could Happen Moving parts such as the pulley flywheel and belt can cause serious injury if they come into contact with you or your clothing Attempting to operate compressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury How To Prevent It Never operate the compressor with guards or covers which are damaged or removed Any repairs required on this product should be performed by authorized service center personnel HAZARD WARNING Risk of Falling What Could Happen A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator 7 ENG For replacement parts contact www allpartsinc com E How To Prevent lt Always operate compressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations A17893 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 HAZARD WARNING Risk of Serious Injury or Property Damage When Transporting Compressor 12 Fire Inhalation Damage to Vehicle Surfaces What Could Happen Oil can leak or spill and could result in fire or breathing hazard serious injury or death
51. nimiento 2 Apagar la unidad colocando el interruptor en On Auto OFF en OFF 3 Usando una llave de tuercas ajustable retire el medidor de salida de presi n y la conexi N r pida del regulador si la tiene Conector r pido 4 Extraiga el regulador 5 Aplique cinta selladora de ca er as sobre el niple del tubo vertical A17893 6 Ensamble el regulador y ori ntelo de acuerdo a lo mostrado NOTA La flecha indica el sentido del flujo del aire Aseg rese que est apuntando a la direcci n en la que fluye el aire 7 Reaplique sellador de ca er as al man metro de presi n externa y a la conexi n r pida 8 Rearme el man metro de presi n de salida y el conector r pido Oriente el man metro de salida para permitir su lectura correctamente Ajuste las conexiones con a llave 44 SP ALMACENAJE Antes de guardar su compresor de aire asegurese de hacer lo siguiente 1 Revise la secci n Mantenimiento de las paginas precedentes y ejecute el mantenimiento programado de acuerdo a la necesidad 2 Apagar la unidad colocando el interruptor en On Auto OFF en OFF 3 Gire el regulador en sentido antihorario y fije la presi n de salida en cero 4 Extraiga la herramienta neum tica o el accesorio 5 Tire del anillo de la v lvula de seguridad permitiendo el purgado del aire del tanque hasta que la presi n del mismo llegue aproximadamente a 20 PSI Suelte el anillo de la v
52. nk during the break in period NOTE Always drain tank on a wash able surface or in a suitable con tainer to prevent damaging or staining surfaces A17893 1 877 475 5660 1 877 475 5660 For replacement parts contact For replacement parts contact 4 Move the On Auto Off lever to ON AUTO position The compressor will start 5 Run the compressor for 15 minutes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain valve clockwise The air receiver will fill to cut out pressure and the motor will stop The compressor is now ready for use Before Each Start Up 1 Place On Auto Off lever to OFF 2 Pull regulator Knob out turn counterclockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect A WARNING Risk of Bursting Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating www allpartsinc com 1 877 475 5660 How to Start 1 Turn the On Auto Off lever to AUTO and allow tank pressure to build Motor will stop when tank pressure reaches cut out pressure 2 Pull the regulator knob out and turn clockwise to incre
53. ommerce MP Marque d pos e de Sears Roebuck and Co A17893
54. onozca y comprenda Esta informacion se relaciona con la proteccion de SU SEGURIDAD y LA PREVENCION DE PROBLEMAS A SU EQUIPO Para ayudarlo a reconocer esta informacion usamos los simbolos indicados mas abajo Sirvase leer el manual y prestar atenci n a estas secciones Z Indica una situaci n AA PRECAUCI N potencialmente peligrosa que si no se evita puede causar lesiones menores o moderadas 20 Wet Usado sin el s mbolo de seguridad de alerta indica una situaci n potencialmente riesgosa la que si no se evita podr a APELIGRO Indica una situaci n de riesgo inminente que si no se evita causar la muerte o lesiones serias Ia ara indica una situ aci n poten cialmente riesgosa que si no se evita podr a causar la muerte o lesiones serias causar da os en la propiedad INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA Algunos tipos de polvo creados por herramientas motorizadas de lijado aserra do amolado esmerilado perforado u otras actividades de la construcci n con tienen materiales qu micos conocidos en el Estado de California como causantes de c ncer defectos de nacimiento u otras lesiones del aparato reproductivo Algunos ejemplos de estos productos qu micos son e El plomo contenido en algunas pinturas con base de plomo e Silice cristalizado proveniente de los ladrillos el cemento y otros productos de alba ileria e Ars nico y cromo provenientes del tratamiento qu mico dado
55. or de presi n del tanque de aire y el interruptor de presi n Retire cuidadosamente la tuber a de alivio de presi n de la v lvula de retenci n 43 SP 5 Desenrosque la v lvula de retenci n gir ndola hacia la izquierda usando una llave de boca de 7 8 plug 22 mm Tome nota de la orientaci n para volverla a ensamblar 6 Usando un destornillador empuje con cuidado el disco de la v lvula hacia arriba y hacia abajo NOTA El disco de la v lvula debe moverse libremente hacia arriba y hacia abajo sobre un resorte que detiene el disco de la v lvula en la posici n cerrada Si no lo hace la v lvula de retenci n necesita ser limpiada o reemplazada En posici n abierta nada es visible En posici n cerrada el disco es visible 7 Limpie o reemplace la v lvula de retenci n Un solvente tal como un removedor de pintura o de barniz puede usarse para limpiar la v lvula de retenci n 8 Aplique sellador a las roscas de la v lvula de retenci n Vuelva a instalar la v lvula de retenci n gire a la derecha 9 Vuelva a instalar la tuber a de alivio de presi n Ajuste las tuercas 10 Vuelva a instalar la tuber a de salida y ajuste las tuercas 11 Ejecute el procedimiento de puesta en marcha Vea Procedimiento de Puesta en Marcha en la secci n Operaci n A17893 Para reemplazar el regulador 1 Libere toda la presi n del aire del tanque Vea Drenaje del tanque en la secci n Mante
56. rar una operacion eficiente y una vida util mas prolongada del com presor de aire debe prepararse y seguirse un programa de mantenimiento de rutina El siguiente programa de mantenimiento de rutina esta disenado para un equipo funcionando diariamente en un ambiente normal de trabajo Si fuese necesario el programa debe ser modificado para adap tarse a las condiciones bajo las cuales se usa Su compresor Las modificaciones dependeran de las horas de operacion y del ambiente de trabajo Los equipos de compresi n funcionando en un ambiente sumamente sucio y hostil requerir n mayor frecuencia de todas las verificacio nes de mantenimiento NOTA Vea en la secci n Operaci n la ubicaci n de los controles 41 SP C mo verificar la v lvula de seguridad y Riesgo de 44 ADVERTENCIA Explosi n Si la v lvula de seguridad no trabaja adecuadamente ello podr determinar la sobrepresi n del tanque creando el riesgo de su ruptura o explosi n 1 Antes de poner en marcha el motor tire del anillo de la v lvula de seguridad para confirmar la seguridad de que la misma opera libremente si la v lvula quedase trabada o no trabajara c modamente deber ser reemplazada por el mismo tipo de v lvula C mo drenar el tanque 1 Apagar la unidad colocando el interruptor en On Auto OFF en OFF 2 Tire de la perilla del regulador y gire en sentido contrario a las agujas de relo para establecer la salida de presi n en cero
57. rcuit or operate the compressor on its own branch circuit 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 AIR COMPRESSOR DIAGRAM Air Compressor Model Number 919 167281 PARTS SHOWN FOR REFERENCE ONLY A17893 Rev 1 Air Compressor MODEL NUMBER 919 16728 1 05 07TS A17893 24 ENG For replacement parts contact www allpartsinc com 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 PARTS LIST Air Compressor Model Number 919 167281 ITEM PART NO NO DESCRIPTION 1 ACG 408 Assembly Fastener 2 D23362 Shroud 3 91895680 Screw 4 ACG 18 Saddle Mount Cup 6 D24233 Filter 7 AC 0558 Grip 8 A16561 Handle 9 SSP 6021 Bushing Reducer 11 Z D27212 Gauge 14 Z D26612 Pressure Switch 15 A17987 Safety Valve 17 D26615 Power Cord 18 LA 2876 Power Cord Label 19 D24888 Nipple 20 SS 2071 Nipple 21 AC 0630 Pressure Relief Tube 22 1000000274 Manifold Assembly 23 D20675 Quick Connect Body 24 A06891 Drain Valve 26 SSP 7811 Nut Sleeve Assembly 1 4 27 A19712 Check Valve 28 D21172 Screw 30 D23363 Shroud 31 SSP 7813 Nut Sleeve Assembly 3 8 32 AC 0774 Isolator 33 AC 0292 Outlet Tube 034 SSP 7821 1 Nut 35 SSG 3105 O ring 36 D27348 Pump Assembly 39 A19277 Nameplate 40 LA 3021 Warning Label 42 LA 3164 Warning Label 43 A16584 La
58. revenirlo Revise y comprenda todas las instrucciones y advertencias contenidas en este manual Familiaricese con los m todos de operaci n y control del compresor de aire Mantenga libre la zona de operaciones de personas animales dom sticos y obst culos Mantenga alejados a los ni os del compresor de aire en todo momento No opere el producto cuando se encuentre fatigado o bajo la influencia de alcohol o drogas Est alerta en todo momento Jam s altere los elementos de seguridad de este producto Equipe la zona de operaciones con un extinguidor de fuego No opere la m quina si sta tiene partes faltantes rotas o no autorizadas CONSERVAR ESTAS INSTRUCCIONES A17893 34 SP GLOSARIO Familiaricese con los siguientes t rminos antes de operar la unidad CFM Cubic feet per minute Pies cubicos por minuto SCFM Stardard cubic feet per minute Pies cubicos estandar por minuto una unidad de medida que permite medir la cantidad de entrega de aire PSIG Pound per square inch Libras por pulgada cuadrada C digo de certificaci n Los productos que usan una o m s de las siguientes marcas UL CUL ETL CETL han sido evaluados por OSHA laboratorios independientes certificados en seguridad y re nen los est ndares suscriptos por los laboratorios dedicados a la certificaci n de la seguridad Presi n m nima de corte Cuando el motor est apagado la presi n del tanque de aire baja a medida qu
59. such as paint paint solvents paint remover insecticides weed killers may contain harmful va pors and poisons A17893 For replacement parts contact www allpartsinc com How To Prevent It Air obtained directly from the compressor should never be used to supply air for human consumption In order to use air produced by this compressor for breathing suitable filters and in line safe ty equipment must be properly installed In line filters and safety equipment used in conjunction with the compressor must be capable of treating air to all appli cable local and federal codes prior to human consumption Work in an area with good cross ventilation Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying Use a NIOSH MSHA ap proved respirator designed for use with your specific application 6 ENG 1 877 475 5660 For replacement parts contact www allpartsinc com 1 877 475 5660 HAZARD WARNING Risk of Burns What Could Happen Touching exposed metal such as the compressor head or outlet tubes can result in serious burns MiSs How To Prevent It Never touch any exposed metal parts on compressor during or immediately after operation Compressor will remain hot for several minutes after operation Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool HAZARD WARNING Risk from Movi
60. ta que el compresor opere desatendido A17893 C mo prevenirlo Siempre opere el compresor en un sector bien ventilado y sin materiales combustibles gasolina o emanaciones de solventes En un rea de rociado de materiales inflamables ubique el compresor por lo menos a 6 1m 20 pies de distancia del rea de rociado Podr a requerirse una extensi n de la manguera Almacene los materiales inflamables en una ubicaci n segura alejados del compresor Jam s coloque objetos apoyados o sobre el compresor Opere el compresor en un sector abierto alejado por lo menos 30 cm 12 de cualquier pared u obstrucci n que restrinja el flujo de aire fresco a las aberturas de ventilaci n Opere el compresor en un sector limpio seco y bien ventilado No opere la unidad en espacios cerrados o cualquier rea confinada Mant ngase siempre alerta cada vez que el producto este funcionando Siempre desconecte el suministro el ctrico moviendo la palanca conmutadora de pre si n a la posici n de apagado off y drene el tanque diariamente o despu s de cada uso 30 SP ADVERTENCIA Riesgo de Explosion Tanque de aire las siguientes condiciones podr an causar el debilitamiento del tanque y causar su explosi n violenta da os a la propiedad o lesiones serias Qu puede occurrir El drenaje inadecuado del agua condensada en el tanque le causa xido que reduce el espesor del tanque de acero Modificaciones o
61. tch cut in pressure Extension cord is wrong length or gauge Check valve stuck open Loose electrical connections Possible defective motor or starting capacitor Paint spray on internal motor parts Pressure release valve on pressure switch has not un loaded head pressure Fuse blown circuit breaker tripped 22 ENG www allpartsinc com www allpartsinc com 1 877 475 5660 CORRECTION Replace Let motor cool off and over load switch will automatically reset Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Check for proper gauge wire and cord length Remove and clean or re place Check wiring connection inside pressure switch and terminal box area Have checked by a Trained Service Technician Have checked by a Trained Service Technician Do not operate the compressor in the paint spray area See flammable vapor warning Bleed the line by pushing the lever on the pressure switch to the OFF position if the valve does not open replace switch 1 Check fuse box for blown fuse and replace as necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit 2 Check for proper fuse You should use a time delay fuse 3 Check for low voltage conditions and or proper extension cord 4 Disconnect the other electrical appliances from ci
62. the motor to restart freely When the motor stops running air will be heard escaping from this valve for a few seconds No air should be heard leaking when the motor is running or after the unit reaches cut out pressure Pressure 13 ENG www allpartsinc com www allpartsinc com Motor Overload Protector The motor has an automatic reset ther mal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools How to Use Your Unit How to Stop 1 Set the On Auto Off lever to OFF Before First Start up AWARNING Risk of Unsafe Operation Serious damage may result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE If quick connect is installed pull coupler back until it clicks to prevent air from escaping through the quick connect 2 Plug the power cord into the correct branch circuit receptacle Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual 3 Open the drain valve fully counterclockwise to permit air to escape and prevent air pressure build up in the air ta
63. tro de aire con agua tibia y exprimalo hasta que seque NOTA Si el filtro de aire est sumamente sucio necesitar ser reemplazado Con sulte la secci n Repuestos para obtener el n mero correcto de la pieza V lvulas de entrada y escape de la bomba del compresor de aire Una vez al a o haga que un T cnico Capacitado de Servicio inspeccione las v lvulas de entrada y escape de la bomba del compresor de aire 42 SP SERVICIO Y AJUSTES Todo tipo de mantenimiento y opera ciones de reparaci n no mencionados deberan ser efectuados por personal t cnico especializado IW Naa Riesgo de Operaci n insegura La unidad arranca autom ticamente cuando est enchufada Al hacer el mantenimiento el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles Antes de intentar hacer reparaciones desconectar el compresor del tomacorriente drenar la presi n de aire del tanque y esperar a que el compresor se enfr e Para reemplazar o limpiar la v lvula de retenci n 1 Libere toda la presi n del tanque de aire Vea C mo Drenar el Tanque en la secci n Mantenimiento 2 Apagar la unidad colocando el interruptor en On Auto OFF en OFF 3 Utilizando una llave regulable afloje la tuerca de salida del tubo del tanque de aire y la bomba Retire cuida dosamente la tuber a de salida de la v lvula de retenci n 4 Utilizando una llave regulable afloje el tubo aliviad
64. un conductor destinado a tierra con una espiga apro piada para su conexi n ver las siguien tes ilustraciones El enchufe debe ser utilizado con un toma corriente que haya sido instalado y conectado a tierra de acuerdo a todos los c digos y ordenanzas locales 1 El cable que acompa a a esta unidad tiene una espiga para conexi n a tierra Esta DEBE ser utilizada con un tomacorriente conectado a tierra IMPORTANTE El tomacorriente que ser utilizado deber haber sido conectado a tierra conforme a todos los c digos locales y ordenanzas A17893 2 Aseg rese de que el tomacorriente que ser utilizado tenga la misma configuraci n que el enchufe de conexi n a tierra NO UTILICE UN ADAPTADOR Ver figura Inspeccione el enchufe y su cord n antes de cada uso No use si existieran signos de da os Si las instrucciones de conexi n Grounded Outlets Ii Grounding Pin a tierra no fueran completamente comprendidas o si se estuviera ante la duda acerca de que el compresor estuviese adecuadamente conectado a tierra haga verificar la instalacion por un electricista competente Riesgo de Descarga El ctrica La conexion inadecuada a tierra puede determinar una descarga el ctrica No modifique el enchufe provisto Si el mismo no penetrara el tomacorriente disponible un electricista competente debera instalar uno apropiado La reparacion del cable o del enchufe DEBERA ser efectuada por un electri
65. you to know and under stand This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS To help you recognize this information we use the symbols below Please read the manual and pay attention to these symbols ADANGER Indicates an imminent A CAUTION Indicates a potentially ly hazardous situation hazardous situation which if not avoided will result in death which if not avoided may result in minor or serious injury or moderate injury Indicates a potentiall Used without the A WARNING A CAUTION safety alert symbol hazardous situation which if not avoided could result in death or serious injury indicates a potentially hazardous situation which if not avoided may result in property damage IMPORTANT SAFETY INSTRUCTIONS AWARNING Some dust created by power sanding sawing grinding drilling and other construction activities contains chemi cals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are e lead from lead based paints e crystalline silica from bricks and cement and other masonry products e arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment always wear MSHA NIOSH approved properly fitting face
Download Pdf Manuals
Related Search
Related Contents
Errex boltless shelving WKUSB Quick Start User Manual DMS - Atkinson Equipment Ltd. Zebra 105936G-003 print head CLIOwin 6.5 QC Software Extension User`s Manual Init NT-TVM204 User's Manual Genius G-Shot V1010 Samsung C27A750X Manual de Usuario BENDIX TCH-005-012 User's Manual Copyright © All rights reserved.