Home
42” Knit Ceiling Fan Owners Manual Ventilador de Techo
Contents
1. Figure 15 WARNING TO REDUCE THE RISK OF PERSONAL INJURY DO NOT BEND THE BLADE HOLDERS WHILE INSTALLING BALANCING THE BLADES OR CLEANING THE FAN DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING BLADES 10 Operating Your Fan NOTE WAIT FOR THE FAN TO STOP BEFORE RE VERSING THE DIRECTION OF THE BLADE RO TATION Turn on the power and check the operation of the fan The pull chain controls the fan speed as follows 1 pull High 2 pulls Medium 3 pulls Low and 4 pulls Off The other pull chain controls the light On and Off Speed settings for warm or cool weather depend on factors such as room size ceiling height number of fans and so on The reverse switch on the light kit cup Figure 14 controls the direction of airflow forward switch down or reverse switch up Reverse Figure 14 Warm weather Forward A downward air flow creates a cooling effect as shown in Figure 15 This allows you to set your air conditioner on a higher setting without af fecting your comfort Cool weather Reverse An upward air flow moves warm air off the ceiling are as shown in Figure 16 This allows you to set your heating unit on a lower setting without affecting your comfort Figure 15 e Na Figure 16 Care of Your Fan Here are some suggestions to help you maintain your fan 1 Because of the fan s natural movement some connections may become loose Check the support
2. N mero de Modelo UL EF200M E 42 1 Normas de seguridad LEE LAS INSTRUCCIONES Y GU RDALAS Para disminuir el riesgo de descarga el ctrica aseg rate de que la electricidad ha sido apagada en el cortacircuitos O la caja de fusibles antes de comenzar la instalaci n Todo el cableado debe cumplir con el C digo Nacional de Electricidad ANSI NFPA 70 1999 y con los c digos locales de electricidad La instalaci n el ctrica debe ser hecha por un electricista certificado y calificado ADVERTENCIA Para reducir el riesgo de incendio o descarga el ctrica no utilices este ventilador con ning n dispositivo de control de velocidad de estado s lido PRECAUCI N Para reducir el riesgo de lesiones f sicas usa s lo los tornillos provistos con la caja el ctrica La caja el ctrica y estructura de soporte deben montarse de forma segura y tener capacidad para sostener de manera confiable un m nimo de 35 libras Usa solamente cajas el ctricas aprobadas por UL marcadas como PARA SOPORTE DE VENTILADOR El ventilador debe ir montado con un m nimo de 7 pies de separaci n entre el borde trasero de las aspas y el piso No operar el interruptor de reversa mientras las aspas del ventilador est n en movimiento El ventilador debe estar apagado y las aspas detenidas antes de invertir la direcci n del movimiento ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES PERSONALES MONTA EL VENTILADOR SOB
3. los tornillos Figura 6 ADVERTENCIA SI NO INSTALAS CORRECTAMENTE EL PASADOR TIPO HORQUILLA SEG N LO INDICADO EN EL PASO 4 Y APRIETAS FIRMEMENTE LOS TORNILLOS COMO SE DESCRIBE EN EL PASO 5 SE PUEDE AFLOJAR Y POSIBLEMENTE SE CAIGA EL VENTILADOR Montaje Cerca del Techo 1 Retira la placa de montaje de la cubierta aflojando los cuatro tornillos de la parte superior de la misma Quita los dos tornillos sin ranura y afloja los tornillos ranurados Esto te permitir retirar la placa de montaje Figura 5 2 Retira la cubierta inferior decorativa de la cubierta oprimiendo los tres pernos Figura 7 Cubierta inferior et _ Figura 7 3 Retira tres de los seis tornillos y arandelas de seguridad alternados que sujetan la placa de refuerzo a la parte superior de la carcasa del motor Figura 8 4 Coloca la junta de goma sobre los otros tres tornillos inserta los cables que salen por la parte superior del motor del ventilador a trav s de la cubierta de techo sobre el collar n en la parte superior del motor Figure 9 5 Alinea los orificios de montaje con los orificios del motor y asegura con los tres tornillos y arandelas de seguridad retiradas en el paso 4 Figura 9 6 Aseg rate de ajustar bien los tornillos de montaje ADVERTENCIA SI NO AJUSTAS CORRECTAMENTE LOS TRES TORNILLOS SEGUN LO INDICADO EN EL PASO 6 SE PUEDEN AFLOJAR Y POSIBLEMENTE SE CAIGA EL VENTILADOR Co
4. Box Green Grounding MUST REST IN THE GROOVE OF THE HANGER BALL FAILURE TO PROPERLY SEAT THE TAB IN THE GROOVE COULD CAUSE DAMAGE TO THE WIRING ____ Ground WARNING to 1 Align the locking slots of the ceiling can Downrod opy with the two screws in the mounting plate Push up to engage the slots and turn clockwise to lock in place Imme diately tighten the two mounting screws firmly 2 Install the remaining two mounting screws into the holes in the canopy and tighten firmly 3 You may now proceed to attaching the fan blades CHECK TO SEE THAT ALL CONNECTIONS ARE TIGHT INCLUDING THE GROUND AND THAT NO BARE WIRE IS VISIBLE AT THE WIRE NUTS EXCEPT FOR THE GROUND WIRE WARNING ELECTRICAL DIAGRAMS ARE FOR REFER ENCE ONLY OPTIONAL USE OF ANY LIGHT KIT SHALL BE UL LISTED AND MARKED SUITABLE FOR USE WITH THIS FAN CLOSE TO CEILING MOUNTING 1 Carefully unhook the fan from the mounting plate and align the locking slots of the ceiling canopy with the two screws in the mounting plate Push up to engage the slots and turn clockwise to lock in place Immediately tighten the two mounting screws firmly Figure 12 2 Install the remaining two mounting screws into the holes in the canopy and tighten firmly 3 You may now proceed to attaching the fan blades WARNING LOCKING SLOTS OF THE CEILING CANOPY ARE PROVIDED ONLY AS AN AID TO MOUNTING DO NOT LEAVE THE FAN ASSEMBLY UNATTENDED UNTIL
5. ALL FOUR CANOPY SCREWS ARE ENGAGED AND FIRMLY TIGHTENED Attaching the Fan Blades 1 Attach blade to blade bracket using the screws provided as shown in figure 13 Please note that the rubber washers are pre attached to the blade bracket Insert a screw into the bracket Repeat for the two remaining screws 2 Tighten each screw securely 3 Fasten the blade assembly to the motor by inserting the alignment post into the slot on the bottom of the motor and tight ening the motor screws Please note that the motor screws are pre attached into the blade bracket Figure 14 4 Repeat steps 1 3 for the remaining blades WARNING PLEASE REMOVE RUBBER MOTOR STOPS ON THE BOTTOM OF THE FAN BEFORE INSTALLING BLADES OR TESTING MOTOR Pre attached rubber pad Figure 13 Figure 14 Light Kit Option Your fan is supplied with a light kit assembly and extra plastic plug for non light option allowing you the option of utilizing your fan with or without the light kit Once you have decided which option you will use proceed with the corresponding instructions Fan with Light Kit Remember to disconnect the power 1 Remove the three mounting screws on the switch cap of the light kit Connect the wires for the light kit exiting the bottom of the motor with the wires from the light kit See Figure 12 Slide the switch cap up and secure the switch cap to the switch housing using the three screws that were removed i
6. Usa bombillas de tipo B de 60 vatios m ximo incluidas Todos los tornillos colocados se deben verificar y ajustar donde sea necesario antes de la instalaci n ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES PERSONALES NO DOBLAR LOS BRAZOS DE LAS ASPAS TAMBI N LLAMADOS REBORDES DURANTE O DESPU S DE LA INSTALACI N EVITA COLOCAR OBJETOS EN LA TRAYECTORIA DE LAS ASPAS ADVERTENCIA POR FAVOR RETIRA LOS TOPES DE GOMA DEL MOTOR DE LA PARTE INFERIOR DEL VENTILADOR ANTES DE INSTALAR LAS ASPAS O DE PROBAR EL MOTOR C mo desempacar el ventilador 2 Desempaca tu ventilador y revisa el contenido Deber tener las siguientes piezas f a Herrajes de montaje de aspas 15 tornillos arandelas de goma 1 Ensamblado del motor 5 Ensamblado de tubo bajante bola preinstaladas al Soportes del aspa 2 Cubierta 6 Ensamblado del kit de luces b Herrajes de montaje 3 Aspas 5 7 Bombillas 3 1 perno 1 pasador tipo horquilla 4 Soportes del aspa 5 8 Cubierta decorativa del collar n del 1 junta de goma con arandelas de goma preinstaladas motor c Herrajes el ctricos y kit de compensaci n Kit de compensaci n de aspas 1 cadena del ventilador para halar 1 cadena del kit de luces para halar 3 conectores pl sticos de cables 1 IMPORTANTE ESTE PRODUCTO Y O SUS COMPONENTES EST N See ea adicional para la PROTEGIDOS POR UNA O MAS DE LAS SIGUIENTES PATENTES DE opci n de la no luz EE UU 5 947 43
7. el paso 3 Equilibrar las aspas Todas las aspas se agrupan por peso Como las maderas naturales var an en densidad el ventilador puede oscilar aunque las aspas tengan el mismo peso El siguiente procedimiento corregir en gran medida la oscilaci n del ventilador Verifica despu s de cada paso 1 Verifica que todas las aspas y tornillos de los soportes de aspas est n seguros 2 La mayor a de los problemas de oscilaci n del ventilador se deben a que las aspas no est n a un mismo nivel Verifica este nivel seleccionando un punto en el techo sobre la punta de una de las aspas Mide desde un punto en el centro de cada aspa a un punto en el techo Mide esta distancia como se muestra en la Figura 16 Rota el ventilador hasta que se posicione la siguiente aspa para su medici n Repite para cada aspa Las mediciones deben estar dentro de 1 8 Enciende el ventilador por 10 minutos 3 Usa el kit de compensaci n de aspas adjunto si sigues notando oscilaci n Punto en el techo Figura 15 ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES PERSONALES NO DOBLAR LOS SOPORTES DE LAS ASPAS DURANTE LA INSTALACI N LAS ASPAS O COMPENSACI N DE LIMPIEZA DEL VENTILADOR NO INSERTES OBJETOS EXTRA OS ENTRE LAS ASPAS EN FUNCIONAMIENTO NOTA ESPERA A QUE SE DETENGA EL VENTILADOR ANTES DE INVERTIR LA DIRECCI N DE GIRO DELAS ASPAS Enciende la electricidad y verifica el funcionamiento del ventilad
8. 6 5 988 580 5 971 573 6 010 110 6 010 306 6 039 541 6 046 416 Y OTRAS PATENTES PENDIENTES 3 C mo instalar el ventilador Herramientas necesarias Destornillador Phillips destornillador plano llave ajustable escalera de tijera y cortacables Opciones de montaje Si no hay una caja el ctrica existente entonces lee las siguientes instrucciones Desconecta la energ a retirando los fusibles o apagando los cortacircuitos Asegura la caja el ctrica directamente a la estructura del edificio Usa sujetadores y materiales de construcci n apropiados La caja el ctrica y su soporte deben sostener completamente el peso en movimiento del ventilador al menos 35 libras No uses cajas el ctricas de pl stico ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA ELECTRICA O LESIONES PERSONALES MONTA EL VENTILADOR SOLO SOBRE UNA CAJA ELECTRICA MARCADA COMO APROBADA COMO SOPORTE DE VENTILADOR Y USA LOS TORNILLOS DE MONTAJE QUE VIENEN CON LA MISMA LAS CAJAS EL CTRICAS UTILIZADAS COMUNMENTE PARAELSOPORTE DE ART CULOS DE ILUMINACI N PUEDEN NO SERVIR COMO SOPORTE DE VENTILADOR Y TAL VEZ DEBAN REEMPLAZARSE EN CASO DE DUDA CONSULTA A UN ELECTRICISTA CALIFICADO Las figuras 1 2 y 3 son ejemplos de diferentes formas de montar el ctrica la caja Figura 1 Caja el ctrica Figura 2 Placa de montaje en el techo el ctrica empotrada Figura 3 Nota Tal vez necesites un tubo bajan
9. Figure 5 Loosen but Do Not Remove Remove Figure 5 Route the wires exiting the top of the fan motor through the motor collar cov er canopy and then through the ball downrod assembly Figure 6 Loosen but do not remove the 2 set screws on the collar on top of the mo tor housing Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Figure 6 Carefully insert the bolt through the holes in the collar and downrod Be careful not to jam the bolt against the wiring inside the downrod Insert the clevis pin and bend to ensure security as noted in the circle inset of Figure 6 5 Tighten the two screws on top of the fan motor firmly Figure 6 Pin in Locked Position Motor Wires Ball Downrod Assembly Ceiling Canopy Figure 6 WARNING FAILURE TO PROPERLY INSTALL THE CLEVIS PIN AS NOTED IN STEP 4 AND PROPERLY TIGHTEN SET SCREWS AS NOTED IN STEP 5 COULD RESULT IN THE FAN LOOSENING AND POSSIBLY FALLING Close to Ceiling Mounting 1 Place the Remove the mounting plate from the canopy by loosening the four screws on the top of the canopy Remove the two non slotted screws and loosen the slotted screws This will enable you to remove the mounting plate Figure 5 Remove the decorative canopy bottom cover from the canopy by depressing the three studs Figure 7 Canopy Bottom Cover cE Figure 7 Remove th
10. LISTED CS 42 Knit Ceiling Fan TURN OF THE _ CO ners Manual CENTURY Ventilador de Techo de 106 7cm Ss Manual del Propietario SKU 355 7007 42 Knit Ceiling Fan A Table of Contents Safety RUlOS oooomoccconnnoccccnnnaccnnnonnas 1 Unpacking Your Fan ccccccncnnonnn 2 Installing Your Fan oooocccccnnonnnnnnss 3 Operating Your Fan cee 10 Care of Your Fan ssccsssseeeeees 11 Troubleshooting ccommmmoccccccnonenass 11 Specifications cecceeeeeeeeees 12 Warranty Information 13 QUESTIONS PROBLEMS MISSING PARTS Please do not return to retailer Call 1 800 749 3267 for any missing parts or questions regarding installation Please reference your SKU 355 7007 or UPC 082392 636609 Safety Rules 1 READ AND SAVE THESE INSTRUCTIONS To reduce the risk of electric shock ensure electricity has been turned off at the circuit breaker or fuse box before beginning All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrician WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state fan speed con trol device CAUTION To reduce the risk of personal injury use only the screws provided with the outlet box The outlet box and support structure must be securely mounted an
11. ND OTHER PATENTS PENDING Tools Required Phillips screw driver straight slot screw driver adjustable wrench step ladder and wire cutters Mounting Options Ifthereisn tan existing outlet box then read the following instructions Disconnect the power by removing fuses or turning off circuit breakers Secure the outlet box directly to the building structure Use the appropriate fasteners and building materials The outlet box and its support must be able to fully support the moving weight of the fan at least 35 Ibs Do not use plastic outlet boxes WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN ONLY TO AN OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT AND USE THE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES MAY NOT BE ACCEPT ABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED CONSULT A QUALIFIED ELEC TRICIAN IF IN DOUBT Figures 1 2 and 3 are examples of differ ent ways to mount the outlet box Figure 1 Outlet Box Figure 2 Installing Your Fan 3 Provide Strong Support Ceiling Recessed S lt t Mounting Outlet Box Plate Figure 3 Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 30 If the canopy touches the downrod re move the decorative canopy bottom cover and turn the can
12. RE UNA CAJA EL CTRICA MARCADA COMO APROBADA COMO SOPORTE DE VENTILADOR Y USA LOS TORNILLOS DE MONTAJE QUE VIENEN CON LA MISMA LAS CAJAS EL CTRICAS UTILIZADAS COMUNMENTE PARA EL SOPORTE DE ART CULOS DE ILUMINACI N PUEDEN NO SERVIR COMO SOPORTE DE VENTILADOR Y TAL VEZ DEBAN REEMPLAZARSE ELECTRICISTA CALIFICADO EN CASO DE DUDA CONSULTA A UN 8 9 10 11 12 13 Evita colocar objetos en la trayectoria de las aspas Para evitar lesiones o da os al ventilador y otros objetos ten cuidado al trabajar cerca del ventilador o al limpiarlo No usar agua o detergentes para limpiar el ventilador o las aspas En general a la hora de limpiar bastar con usar un pa o seco o ligeramente humedecido Despu s de concluir con las conexiones el ctricas debes voltear los conductores empalmados hacia arriba y empujarlos con cuidado hacia dentro de la caja el ctrica Los cables deben estar separados con el cable a tierra y el conductor a tierra del equipo hacia uno de los lados de la caja el ctrica Los diagramas el ctricos son s lo una referencia Los kits de luces no empaquetados con el ventilador deben estar aprobados por UL y marcados como apropiados para ser usados con el modelo de ventilador a instalar Los interruptores deber n estar clasificados por el UL como de Uso General Consulta las instrucciones adjuntas a los kits de luces e interruptores para obtener informaci n sobre el ensamblaje adecuado
13. ar los diferentes procedimientos a seguir para los dos tipos de instalaci n Montaje de techo est ndar 1 Retira la placa de montaje de la cubi erta aflojando los cuatro tornillos de la parte superior de la misma Quita los dos tornillos sin ranura y afloja los tornil los ranurados Esto te permitir retirar la placa de montaje Figura 5 Aflojar pero no retirar Quitar Figura 5 2 Inserta los cables que salen por la parte superior del motor del ventilador a trav s de la cubierta y luego a trav s del ensamblado del tubo bajante y la bola Figura 6 3 Afloja sin quitarlos los tornillos en el col lar n ubicado en la parte superior de la carcasa de motor 4 Alinea los orificios en la parte inferior del tubo bajante con los orificios en el col lar n de la parte superior de la carcasa de motor Figura 7 Inserta con cuidado el perno a trav s de los orificios del col lar n y del tubo bajante Ten cuidado de 5 no apretarlo contra el cableado dentro del tubo bajante Inserta el pasador tipo horquilla en el orificio cercano al extre mo del perno y d blalo para garantizar la seguridad tal como se muestra en el c rculo de la Figura 6 Vuelve a ajustar los dos tornillos del col lar n en la parte superior de la carcasa del motor Figura 6 Posici n de cierre del pasador Cables del motor Cubierta del collar n gee del motor Perno Collarin del motor Pasador tipo horquilla
14. con un Juego de luces ensamblaje y un enchufe pl stico adicional para la opci n de la no luz permiti ndole la opci n de utilizar su ventilador con o sin el juego de luces Una vez que usted ha decidido qu opci n usted utilizar proceda con las instrucciones correspondientes Ventilador Con el Juego De Luces Recuerde desconectar la energ a 1 Quite los tres tornillos de montaje en caja del interruptor del juego de luces 2 Conecte los alambres para el juego de luces que sale la parte inferior del motor con los alambres del juego de luces V ase la figura 12 3 Deslice la caja del interruptor para arriba y asegure la caja del interruptor a la cubierta del interruptor usando los tres tornillos que fueron quitados en el paso 1 4 Quite la l mpara de vidrio y la tuerca 5 Cuando la energ a este apagada inserte los bulbos de 60W maximo incluidos en el juego de luces 6 Inserte la l mpara de vidrio y aseg rela con la tuerca La cadena de tirar debe salir del soporte 7 La cadena de tirar para la velocidad pasa a trav s de los agujeros del soporte Ventilador Sin el Juego De Luces 1 Quite el casquillo del interruptor del juego de luces 2 Inserte el enchufe pl stico alos agujeros de la cubierta del interruptor 3 Quite los tres tornillos del casquillo del interruptor 4 Ate el casquillo del interruptor a la cubierta del interruptor usando los tres tornillos que fueron quitados en
15. connections brackets and blade attachments twice a year Make sure they are se cure It is not necessary to remove the fan from the ceiling Clean your fan periodically to help maintain its new appearance over the years Do not use water when clean ing this could damage the motor or the wood or possibly cause an electri cal shock Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Warning Make sure the power is off before cleaning your fan You can apply a light coat of furniture polish to the wood for additional protec tion and enhanced beauty Cover small scratches with a light application of shoe polish There is no need to oil your fan The motor has permanently lubricated sealed ball bearings 11 Troubleshooting Problem Solution Fan will not start 1 2 Fan sounds noisy 1 2 3 Check the main and branch circuit fuses or breakers CAUTION Make sure the main power is off Check the line wire connections to the fan and switch wire connections in the switch housing Make sure all motor housing screws are snug Make sure the screws that attach the fan blade bracket to the motor hub are tight Make sure the wire nut connections are nat rattling against each other or the interior wall of the switch housing CAUTION Make sure the power is off Allow a 24 hour breaking in period Most nois
16. correct such defects without charge or at our option replace with a comparable or superior model if the product is returned to the manufacturer To obtain warranty service you must present a copy of the receipt as proof of purchase All costs of removing and reinstalling the product are your responsibility Damage to any part such as by accident or misuse or improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in plated finishes including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty The manufacturer hereby disclaims any and all war ranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which can not be disclaimed is limited to the time period as specified in the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you The manufacturer shall not be liable for incidental consequential or special damages arising out of or in connection with produ
17. ct use or performance except as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the customer Warranty Information 13 IMPORTANT NOTE To ensure warranty service if ever necessary please register your fan at gpwarranty com You must present a copy of the original purchase receipt to obtain warranty service G P WARRANTY SERVICE CENTER INC WARRANTY SECTION 1951 N W 22nd STREET FORT LAUDERDALE FLORIDA 33311 Knit de 42 ventilador de techo ndice Normas de seguridad s008 1 Como desempacar el ventilador 2 C mo instalar el ventilador 3 C mo operar el ventilador 10 Cuidado del ventilador 11 Soluci n de problemas 00 11 Especificaciones seseeeeeees 12 Informacion de garant a mcc 13 PREGUNTAS PROBLEMAS O PIEZAS FALTANTES Por favor no devuelva al vendedor minorista Llame a 1 800 749 3267 para cubrir las partes faltantes o cuestiones relacionadas con la instalaci n Por favor usa como referencia el N de SKU 355 7007 o UPC 082392 636609
18. ctricista con licencia para que instale el ventilador Sigueestospasosparaconectartuventilador a tu circuito dom stico Usa las tuercas de conexi n de cables que vienen con tu ventilador Asegura los conectores con cinta aislante Aseg rate de que no existan conexiones o cables sueltos 1 Conecta el conductor a tierra del cable de 120 voltios puede ser un cable desnudo o un cable con aislante verde al los cable s terminal es a tierra verde s del ventilador Figura 12 Cuando uses el montaje de techo est ndar existen dos cables terminales a tierra verdes uno desde la placa de montaje de techo y otro desde el ensamblado del tubo bajante y la bola Cuando uses el montaje cerca del techo existe solamente un cable terminal a tierra verde desde la placa de montaje ya que no se usa el ensamblado de tubo bajante y bola 2 Conecta el cable blanco del motor del ventilador al cable blanco de suministro neutro usando una tuerca de cable Figura 12 f 3 Conecta el cable negro del motor del ventilador al cable negro de suministro de energ a positivo usando una tuerca de cable Figura 12 4 Conecta el cable azul para el kit de luces al cable negro del circuito de la casa 5 Voltea hacia arriba las conexiones de tuerca de cable separ ndolas para que el cable verde a tierra est en un lado de la caja el ctrica y los cables blanco negro y azul est n del otro lado y emp jalos con cuidado dentro de la caja
19. d capable of reliably supporting a minimum of 35 pounds Use only UL Listed outlet boxes marked FOR FAN SUPPORT The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor Donotoperate the reverse switch while fan blades are in motion Fan must be turned off and blades stopped be fore reversing the blade direction WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE OUTLET BOX MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED CONSULT A QUALIFIED ELECTRI CIAN IF IN DOUBT 8 Avoid placing objects in the path of the blades 9 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After making electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box 12 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable
20. dos tornillos de la placa de montaje Alza para enganchar las ranuras y gira de izquierda a derecha para asegurar en su sitio Ajusta con firmeza los dos tornillos de montaje 2 Instala los dos tornillos de montaje restantes en los orificios de la cubierta y aprieta firmemente 3 Ahora puedes proceder a montar las aspas del ventilador ADVERTENCIA LAS RANURAS DE CIERRE DE LA CUBIERTA DEL TECHO S LO SIRVEN DE AYUDA DURANTE LA INSTALACI N NO DEJES SIN SUPERVISI N EL ENSAMBLADO DEL VENTILADOR HASTA QUE LOS CUATRO TORNILLOS DE LA CUBIERTA SE FIJEN Y AJUSTEN FIRMEMENTE C mo montar las aspas del ventilador 1 Fija el aspa a su soporte con los tornillos provistos seg n se muestra en la Figura 13 Observa que las arandelas de goma est n fijadas en el soporte del aspa Inserta el tornillo en el soporte Repite para los otros dos tornillos 2 Aprieta todos los tornillos de manera firme 3 Ajusta el brazo del aspa al motor insertando los postes de alineaci n dentro de la ranura de la parte inferior del motor y aprieta los tornillos del motor Por favor ten en cuenta que los tornillos del motor est n en los soportes del aspa Figura 14 4 Repite los pasos 1 2 y 3 para las aspas restantes ADVERTENCIA RETIRA LOS TOPES DE GOMA DEL MOTOR EN LA PARTE INFERIOR DEL VENTILADOR ANTES DE INSTALAR LAS ASPAS O PROBAR EL MOTOR Figura 13 Figura 14 Opci n juego de luces Su ventilador viene empaquetado
21. el ctrica ADVERTENCIA VERIFICA QUE TODAS LAS CONEXIONES EST N BIEN AJUSTADAS INCLUIDA LA CONEXI N A TIERRA Y QUE NO HAYA NING N CABLE PELADO VISIBLE EN LAS TUERCAS PARA CABLE EXCEPTO EL DE TIERRA ADVERTENCIA LOS DIAGRAMAS EL CTRICOS SON S LO UNA REFERENCIA EL USO OPCIONAL DE KITS DE LUCES DEBE ESTAR APROBADO POR UL Y ESTAR MARCADO COMO ADECUADO PARA SER USADO EN ESTE VENTILADOR CIRCUITO DE SUMINISTRO BLANCO Caja el ctrica Cable verde terminal a tierra Tierra al tubo bajante BLANCO BLANCO Figura 12 Finalizar la instalaci n del ventilador MONTAJE DE TECHO EST NDAR ADVERTENCIA CUANDO USES EL MONTAJE DE TUBO BAJANTE Y BOLA EST NDAR LA PESTA A EN EL ARO EN LA PARTE INFERIOR DE LA PLACA DE MONTAJE DEBE ENCAJAR EN LA RANURA DE LA BOLA DE SOPORTE SI NO ENCAJA CORRECTAMENTE SE PUEDE DA AR EL CABLEADO 1 Alinea las ranuras de cierre de la cubierta de techo con los dos tornillos de la placa de montaje Alza para enganchar las ranuras y gira de izquierda a derecha para asegurar en su sitio Ajusta con firmeza los dos tornillos de montaje 2 Instala los dos tornillos de montaje restantes en los orificios de la cubierta y aprieta firmemente 3 Ahora puedes proceder a montar las aspas del ventilador MONTAJE CERCA DEL TECHO 1 Con cuidado desengancha el ventilador de la placa de montaje y alinea las ranuras de cierre de la cubierta del techo con los
22. es associated with a new fan disappear during this time If using the Ceiling Fan light kit make sure the tensioners or screws securing the glassware are tight Check that the light bulb is also secure Make sure the canopy is a short distance from the ceiling It should not touch the ceiling Make sure your outlet box is secure and rubber isolator pads were used between the mounting bracket and outlet box Make sure pull chains are not vibrating against glass or housing WARNING MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BE FORE YOU ATTEMPT TO MAKE ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS 12 Specifications NET GROSS e710 5 FAN SIZE SPEED VOLTS AMPS WATTS RPM WEIGHT WEIGHT FEET 18 26 20 02 g CEACE T 2850 Tas Tes He 2w ose oo is se These are approximate measures They do not include Amps and Wattage used by the light kit Lifetime Limited Warranty Lifetime Warranty on Motor The manufacturer warrants the fan motor to be free from defects in workmanship and material present at the time of shipment from the factory for a lifetime after the date of purchase by the original purchaser The manufacturer also warrants that all other fan parts excluding any glass or acrylic blades to be free from defects in workmanship and material at the time of shipment from the factory for a period of one year after the date of purchase by the original purchaser We agree to
23. es necesario desmontar el ventilador del techo Limpia tu ventilador con frecuencia para que luzca como nuevo a pesar de los a os No uses agua al limpiar esto puede da ar el motor o la madera o causar descargas el ctricas Usa solamente un cepillo suave o trapo sin pelusas para evitar ara ar el acabado El revestimiento est sellado con laca para minimizar la decoloraci n u opacidad Advertencia Aseg rate de que la corriente est apagada antes de limpiar el ventilador Puedes aplicar una fina capa de pulimento para muebles a la madera para una mayor protecci n y belleza Cubre los ara azos peque os con una leve aplicaci n de lustrador para calzado Tu ventilador no necesita lubricaci n El motor tiene cojinetes de bola sellados permanentemente lubricados Soluci n de problemas Problem Soluci n El ventilador no 1 enciende 2 El ventilador hace 1 ruido Verifica fusibles o disyuntores principales y secundarios PRECAUCI N Aseg rate de que est desactivada la electricidad principal Verifica conexiones de cables en l nea al ventilador y conexiones de cables del interruptor en la caja de interruptores Aseg rate de que los tornillos de la carcasa del motor est n ajustados Aseg rate de que los tornillos que unen el soporte de aspa al cuerpo del motor est n bien ajustados Aseg rate de que las conexiones de tuerca de cable no choquen unas con otras o con la pared interior de la caja del interr
24. for use with the model fan you are in stalling Switches must be UL general use switches Refer to the instructions packaged with the light kits and switches for proper assembly Use 60W MAX BULBS Type B supplied 13 All set screws must be checked and tightened where necessary before installation WARNING TO REDUCE THE RISK OF PERSONAL INJURY DO NOT BEND THE BLADE BRACKETS ALSO REFERRED TO AS FLANGES DURING ASSEMBLY OR AFTER INSTALLATION DO NOT INSERT OBJECTS IN THE PATH OF THE BLADES WARNING PLEASE REMOVE RUBBER MOTOR STOPS ON THE BOTTOM OF THE FAN BEFORE INSTALLING BLADES OR TESTING MOTOR 2 Unpacking Your Fan Unpack your fan and check the contents You should have the following items Blade Attachment Hardware 1 Fan Motor Assembly 5 Ball downrod Assembly 15 screws rubber washers 2 Canopy 6 Light Kit with Glass Shade pre attached to the brackets 3 Blades 5 7 Bulbs 2 b Mounting Hardware 4 Blade Bracket Set with Rubber Washers 8 Decorative Motor Collar Cover 1 Bolt 1 Clevis Pin 1 Rubber Gasket c Electrical Hardware amp Balancing Kit Blade Balancing Kit 3 Plastic Wire Connectors 1 Pull Chain for the Fan 1 Pull Chain for the Light Kit 1 Plastic IMPORTANT THIS PRODUCT AND OR COMPONENTS ARE COVERED Plug for Non Light Kit Option BY ONE OR MORE OF THE FOLLOWING U S PATENTS 5 947 436 Pre installed 5 5 988 580 5 971 573 6 010 110 6 010 306 6 039 541 6 046 416 A
25. ha como parte de una reclamaci n de garant a deben ser pagados por el cliente
26. holes at the outer rim of the ceil ing canopy Figure 11 If using stan dard mounting seat the hanger ball in the mounting plate socket Make sure the tab on the mounting plate socket is properly seated in the groove in the hanger ball Figure 11 UL Listed Mounting Screws supplied with Outlet Box Mounting Bracket Over 120V Screw Wires Heads Bracket Figure 10 CAUTION WHEN MOUNTING THE FAN ON A SLOPED CEILING THE STANDARD BALL DOWNROD MOUNTING METHOD MUST BE USED MAKE SURE THE MOUNTING PLATE SLOTS ARE ON THE LOWER SIDE BY SLIDING THE MOUNTING PLATE FROM THE TOP DOWN Close to Ceiling Mounting Standard Mounting Figure 11 WARNING THE HOOK AS SHOWN IN FIGURE 11 IS ONLY TO BALANCE THE FAN WHILE ATTACHING WIRING FAILURE TO HANG AS SHOWN IN FIGURE 11 MAY RESULT IN THE HOOK BREAKING CAUSING THE FAN TO FALL THE HOOK MUST PASS FROM INSIDE TO OUTSIDE OF THE CANOPY WARNING WHEN USING THE STANDARD BALL DOWN ROD MOUNTING THE TAB IN THE RING AT THE BOTTOM OF THE MOUNTING PLATE MUST REST IN THE GROOVE OF THE HANGER BALL FAILURE TO PROPERLY SEAT TAB IN THE GROOVE COULD CAUSE DAMAGE TO THE WIRING WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE A SOLID STATE SPEED CONTROL WITH THIS FAN IT WILL PERMANENTLY DAMAGE THE ELECTRONIC CIRCUITRY Making the Electrical Connections REMEMBER to disconnect the power If you feel you do not have enough electrica
27. l wiring knowledge or experience have your fan installed by a licensed electrician Follow the steps below to connect the fan to your household wiring Use the wire connecting nuts supplied with your fan Secure the connectors with electrical tape Make sure there are no loose strands or connections 1 Connect the ground conductor of the 120v supply this may be a bare wire or a wire with green insulation to the green ground lead s of the fan Figure 12 When using standard ceiling mounting there are two green grounding leads one from the ceiling mounting plate and one from the ball downrod assembly When using Close to Ceiling mount ing there is only one green ground lead from the mounting plate since the ball downrod assembly is not used 2 Connect the fan motor white wire to the supply white neutral wire using a wire nut Figure 12 3 Connect the fan motor black wire to the supply black hot wire using a wire nut Figure 12 4 Connect the blue wire for the light kit to the black household wire 5 Turn the wire connections upward I spreading them apart so the green Installation ground and white wires will be on one STANDARD CEILING MOUNTING side of the outlet box and the black and Outlet WARNING blue wires will be on the other side and WHEN USING THE STANDARD BALL push into the outlet box DOWNROD MOUNTING THE TAB IN THE RING AT THE BOTTOM OF THE MOUNTING PLATE Finishing the Fan SUPPLY CIRCUIT
28. llar n del motor Tornillo y arandela gt de seguridad 3 de 6 tornillos Figura 8 Tornillo y arandela de seguridad 3 tornillos goma Figura 9 C mo instalar el ventilador en la caja el ctrica 1 Pasa los cables de suministro de 120 voltios a trav s del orificio central de la placa de montaje del techo como se muestra en la Figura 10 2 Instala la placa de montaje de techo sobre la caja el ctrica deslizando la placa de montaje sobre los dos tornillos suministrados con la caja el ctrica Cuando uses un montaje cerca del techo es importante que la placa de montaje est nivelada Si es necesario usa arandelas niveladoras no incluidas entre la placa de montaje y la caja el ctrica Nota que el lado plano del soporte de montaje est hacia la caja el ctrica Figura 10 3 Ajusta firmemente los dos tornillos de montaje 4 Con cuidado alza el ensamblado hacia la placa de montaje del techo y cuelga el ventilador del gancho suministrado usando uno de los orificios en el borde exterior de la cubierta de techo Figura 11 Si usas el montaje est ndar asienta la bola de soporte en la placa del soporte de montaje Aseg rate de que la pesta a sobre el casquillo de soporte de montaje encaje bien dentro de la ranura de la bola de soporte Figura 11 Caja el ctrica aprobada Tornillos de montaje provistos con la caja el ctrica Gancho Desliza el soporte de montaje sobre la cabeza de lo
29. n Step 1 4 Remove the nut and glass shades 5 Turn the power off insert the bulbs included into the light kits Max 60W candelabra Insert the glass shade and secure it with the nut The pull chain should come out from the support bracket Pull chain for speed selection passes through the holes of another support bracket Fan without Light Kit 1 2 Remove the switch cap from the light kit Insert the plastic plug to the holes of the switch housing Remove the three screws from switch cap Attach the switch cap to switch housing using the three screws that were removed in step 3 Blade Balancing All blades are grouped by weight Because natural woods vary in density the fan may wobble even though the blades are weight matched The following procedure should correct most fan wobble Check after each step 1 Check that all blade screws are secure 2 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceil ing above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceil ing Measure this distance as shown in Figure 15 Rotate the fan until the next blade is positioned for measurement Repeat for each blade Measurement deviations should be within 1 8 Run the fan for 10 minutes 3 Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable Ceiling
30. no presenta defectos de fabricaci n ni de material desde la fecha de salida de la f brica El fabricante tambi n garantiza por un per odo de un a o a partir de la fecha de compra por el comprador original que todas las dem s piezas del ventilador sin incluir ninguna aspa de vidrio o acr lico no presentar n ning n defecto de fabricaci n o de material desde el momento de su salida de la f brica Acordamos reparar NOTA IMPORTANTE todos los defectos del tipo antes mencionado sin cargo alguno o a nuestra discreci n reemplazar el producto por un modelo de calidad comparable o superior si el producto se devuelve a el fabricante Para obtener una garant a de servicio usted debe presentar una Para asegurar la garant a de servicio si es necesario registre su ventilador en copia del recibo como comprobante de compra Todos los costos de retiro y reinstalaci n gpwarranty com del producto son su responsabilidad Da os a cualquiera de las piezas como resultado de accidentes instalaci n o uso incorrectos o debidos a la instalaci n de cualquier accesorio Usted debe presentar una copia del no est n cubiertos bajo esta garant a Debido a que las condiciones clim ticas pueden recibo de compra original para obtener variar esta garant a no cubre ning n cambio en el acabado revestido incluyendo xido garant a de servicio picaduras corrosi n manchas o descascaramiento Los acabados de bronce de este tipo tienen una vida til m
31. opy 180 before attaching the canopy to the mounting plate Outlet Box Figure 4 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 4 Hanging the Fan REMEMBER to turn off the power Follow the steps below to hang your fan properly NOTE This ceiling fan is supplied with two types of hanging assemblies the standard ceiling installation using the downrod with ball and socket mounting and the close to ceiling mounting The close to ceiling mounting is recommended in rooms with less than 8 foot ceilings or in areas where additional space is desired from the floor to the fan blades When using standard downrod installation the distance from the ceiling to the bottom of the fan blades will be approximately 10 inches The close to ceil ing installation reduces the distance from the ceiling to the bottom of the fan blades to approximately 6 inches Once you have decided which ceiling installation you will use proceed with the following instructions Where necessary each section of the instructions will note the different procedures to follow for the two types of installation Standard Ceiling Mounting 1 Remove the mounting plate from the canopy by loosening the four screws on the top of the canopy Remove the two non slotted screws and loosen the slotted screws This will enable you to remove the mounting plate
32. or El interruptor de cadena controla las velocidades del ventilador de la siguiente manera 1 vez Alto 2 veces Medio 3 veces Bajo y 4 veces Apagado El otro interruptor de cadena sirve para Encender y Apagar la luz Las configuraciones de velocidad para clima c lido o fr o dependen de factores como tama o de la habitaci n altura del techo cantidad de ventiladores y dem s El interruptor de reversa instalado en la caja del interruptor Figura 14 controla la direcci n del flujo de aire hacia delante Interruptor de reversa Figura 16 Clima c lido Hacia adelante Un flujo de aire hacia abajo crea un efecto refrescante como se muestra en la Figura 15 Esto te permite fijar tu aire acondicionado en una configuraci n m s alta sin afectar tu comodidad hacia abajo o reversa hacia arriba a Be N Figura 17 Como operar el ventilador 10 Clima fresco Reversa Un flujo de aire hacia arriba mueve el aire calido lejos del techo como se muestra en la Figura 16 Esto te permite fijar tu unidad de calefacci n en una configuraci n m s baja sin afectar tu comodidad Figura 18 11 Cuidado del ventilador Aqu tienes algunas sugerencias para el mantenimiento de tu ventilador 1 Debido al movimiento natural del ventilador algunas conexiones pueden aflojarse Revisa las conexiones de soporte soportes y accesorios de aspas dos veces al a o Verifica que est n seguros No
33. ree of the six screws and lock washers every other one securing the reinforcing plate to the top of the fan mo tor housing Figure 8 rubber gasket over the remaining three screws route the wires exiting the top of the fan motor through the ceiling canopy over the collar at the top of the motor Figure 9 5 Align the mounting holes with the holes in the motor and fasten using the three screws and lock washers removed in step 3 Figure 9 6 Tighten the mounting screws securely WARNING FAILURE TO COMPLETELY TIGHTEN THE THREE SCREWS IN STEP 6 COULD RESULT IN THE FAN LOOSENING AND POSSIBLY FALLING Motor Collar Screw and Q gt Lockwasher 3of6 Figure 8 Figure 9 Installing Fan to the Outlet Box 1 Pass the 120 volt supply wires through the center hole in the ceiling mounting plate as shown in Figure 10 Install the ceiling mounting plate on the outlet box by sliding the mounting plate over the two screws provided with the outlet box When using the close to ceiling mounting it is important that the mounting plate be level If necessary use leveling washers not included between the mounting plate and the outlet box Note that the flat side of the mounting plate is toward the outlet box Figure 10 Securely tighten the two mounting Screws 6 4 Carefully lift the assembly up to the ceil ing mounting plate and hang the fan on the hook provided by utilizing one of the
34. s tornillos Placa de montaje en el techo Figura 10 Cables de 120V PRECAUCI N CUANDO MONTES EL VENTILADOR EN UN TECHO INCLINADO DEBES USAR EL M TODO DE MONTAJE CON TUBO BAJANTE Y BOLA EST NDAR LA PLACA DE MONTAJE DEBE ESTAR INSTALADA DE MANERA TAL QUE LAS ABERTURAS EN FORMA DE RANURA QUEDEN EN EL LADO INFERIOR DESLIZANDO LA PLACA DE MONTAJE DESDE LA PARTE SUPERIOR HACIA ABAJO Montaje cerca del techo Montaje est ndar ADVERTENCIA EL GANCHO COMO SE MUESTRA EN LA FIGURA 11 SOLAMENTE ES PARA EQUILIBRAR EL VENTILADOR MIENTRAS SE CONECTAN LOS CABLES SI NO SE CUELGA COMO SE MUESTRA EN LA FIGURA 11 PUEDE ROMPERSE EL GANCHO Y EL VENTILADOR SE CAER EL GANCHO DEBE PASAR DE ADENTRO HACIA FUERA DE LA CUBIERTA ADVERTENCIA CUANDO USES EL MONTAJE DE TUBO BAJANTE Y BOLA ESTANDAR LA PESTA A EN EL ARO EN LA PARTE INFERIOR DE LA PLACA DE MONTAJE DEBE ENCAJAR EN LA RANURA DE LA BOLA DE SOPORTE SI NO ENCAJA CORRECTAMENTE SE PUEDE DA AR EL CABLEADO ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO O DESCARGA EL CTRICA NO UTILICES ESTE VENTILADOR CON NINGUN DISPOSITIVO DE CONTROL DE VELOCIDAD DE ESTADO S LIDO DE MONTAJE EN PARED EL CIRCUITO ELECTR NICO SE DA AR EN FORMA PERMANENTE Figura 11 C mo hacer las conexiones el ctricas RECUERDA desconectar la electricidad Si crees que no tienes suficiente experiencia o conocimientos en cableado el ctrico contrata a un ele
35. s prolongada cuando se protegen de las condiciones clim ticas G P wARRANTY SERVICE CENTER INC cambiantes Es normal cierta oscilaci n y no se considerar una falla Cualquier servicio WARRANTY SECTION t cnico conducido por personas no autorizadas anular la garant a No hay ninguna otra 1951 N W 22nd STREET garant a expresa Mediante la presente el fabricante se exime de cualquier garant a PS incluyendo pero sin limitarse a aquellas de comercializaci n e idoneidad para un fin FORT LAUDERDALE FLORIDA 33311 particular de acuerdo a lo contemplado por la ley La duraci n de cualquier garant a impl cita que no se pueda eximir est limitada al per odo de tiempo especificado en la garant a expl cita Algunos estados no permiten limitaciones en la duraci n de la garant a por consiguiente la limitaci n anterior puede no aplicarse a usted El fabricante no ser responsable por da os directos indirectos o especiales que resulten o deriven del uso o rendimiento del producto excepto en casos en que lo estipule la ley Algunos estados no permiten la exclusi n o limitaci n de da os directos o indirectos por lo que la limitaci n o exclusi n anterior podr a no aplicarse a usted Esta garant a le otorga derechos legales espec ficos pero es posible que tambi n tenga otros derechos que var an de un estado a otro Esta garant a sustituye todas las garant as anteriores Los costos de env o de cualquier devoluci n de productos hec
36. te m s largo para mantener la altura m nima adecuada de las aspas al instalar el ventilador en un techo inclinado El ngulo m ximo permitido es de 30 Si la cubierta toca el tubo bajante retira la cubierta inferior decorativa y gira la cubierta 180 antes de fijar la cubierta a la placa de montaje Caja el ctrica Figura 4 Para colgar tu ventilador donde haya una l mpara pero ninguna viga de techo tal vez necesites una barra colgante de instalaci n como se muestra en la Figura 4 C mo colgar el ventilador RECUERDA desconectar la corriente Sigue estos pasos para colgar correctamente tu ventilador NOTA Este ventilador de techo viene con dos tipos de ensamblados de soporte la instalaci n de techo est ndar con tubo bajante y bola y casquillo de montaje y el montaje cerca del techo El montaje cerca del techo se recomienda en habitaciones con techos de menos de 8 pies de altura o en reas donde sedeseeespacioadicionaldesdeelpisohasta las aspas de ventilador Cuando uses una instalaci n con un tubo bajante est ndar la distancia desde el techo a la parte inferior de las aspas ser de 11 pulgadas aproximadamente La instalaci n cerca del techo reduce la distancia desde el techo a la parte inferior de las aspas a 7 pulgadas aproximadamente Una vez elegido el tipo de instalaci n sigue con las siguientes instrucciones Cuando sea necesario cada secci n de las instrucciones indic
37. uptor PRECAUCION Aseg rate de que est desconectada la electricidad Permite un per odo de 24 horas de adaptaci n La mayor a de los ruidos asociados con un nuevo ventilador desaparecen en ese per odo Si usas el kit de luces de ventilador de techo aseg rate de que los tensores o los tornillos que sujetan el vidrio est n bien ajustados Verifica que la bombilla est bien asegurada Aseg rate de que la cubierta est a corta distancia del techo No debe tocar el techo Aseg rate de que tu caja el ctrica est bien segura y las almohadillas aislantes de goma se hayan instalado entre el soporte de montaje y la caja el ctrica Aseg rate de que las cadenas para halar no choquen contra el vidrio O la carcasa ADVERTENCIA ASEG RATE DE QUE EST DESCONECTADA LA ELECTRICIDAD EN EL PANEL DE ELECTRICIDAD ANTES DE INTENTAR HACER REPARACIONES CONSULTA LA SECCI N C MO HACER LAS CONEXIONES EL CTRICAS Especificaciones 12 PIES C B PESO 10 PIES TAMANO VELOCIDAD VOLTIOS AMPERIOS VATIOS RPM X MIN NETO BRUTO C B Pap io os tn 18 26 20 02 e ue an Pos Ja Jus ame at 2 De me oe Jo ae Estas son las medidas aproximadas No incluyen ni el amperaje ni el vataje consumido por el kit de luces 13 Garant a limitada de por vida Garant a de por vida para el motor El fabricante garantiza de por vida a partir de la fecha de compra por el comprador original que el motor del ventilador
Download Pdf Manuals
Related Search
Related Contents
製品詳細 Entretien des pinces à sertir et… User Manual - Jive Communications, Inc. APC 990 Switch User Manual Page 1 Page 2 このたびは~ エスコン回裏二 フレックス をご採】いただき Brodit Passive Holder,Tilt Swivel USER`S MANUAL VIVOTEK PT3122 webcam de spelregels Copyright © All rights reserved.