Home
        PSC-Z Controller - Do-It
         Contents
1.     Change settings     STEP 2  SET OR CHANGE STATION INFORMATION            1  Press        STATION CYCLES   7      PER Bay    N                PROGRAMA   1   DAYS   CYCLE TIME APART  NEXTWATER WED    N          3  Press or Move to cycle time  cycles    per day  days apart   station number     Press    or    Change settings or    station number   4  Set any unused stations to zero cycle time     5  Hold down      For 4 secs  to adjust delay  time between cycles   optional      6  Press      or    Adjust cycle delay time     from 30 min  to 12 hrs    for A or B         Quick START    STEP 3  SET START TIMES wuss    1  Press          START TIME       PROGRAM A HH                    F          3  Press or Move from hours to    minutes     Press 0  or S Set time watering will begin     Only one start time  per program is set   PSC Z calculates the rest     STEP 4  SET NO WATER       5            4                        NO  1  Press DAYS   DAYS       N    NO  WATER SUN MON TUE WED THU FRI SAT         3  Press or Move from day to day     Press    or    Select no water days   underlined      PROGRAMMING THE PSC Z CONTROLLER  Moving About the Display                             Use the four buttons in the center of the control panel to move  about the display             3       O O    Press to move from field to field  Press to change the flashing value   The active field flashes  or to select days     Set Clock and              Press 1 To display       Set time and day before  se
2.   No  of cycles per day   up to 14 per program   28 total per station     2 separate programs   Aand B B    Cycle lengths up  Station number to 3 hours  59 minutes          STATION         CYCLES    Pho dn 0g            Seasonal    PROGRAM A  adjust     Lr        DAYS    indicator E CYCLE TIME APART          NEXTWATER WED    Next day Days between  to water waterings  up to 14     Keypad D efinitions                   ne    e    SEASONAL Increase or decrease all  ADJUST watering times    Switch from Program A to  Program B    Manually run a single  station      Pause watering during  automatic runs     Cancel a manual run     Go backto time and day  display when programming    TIME Set current time and day   DAY AM PM or 24 hour    STATION Program a station for  automatic watering    Set time that Program A  Simes   and or B will start  watering    Run an entire program  including all repeat cycles    Stop or restart automatic  program watering    E    Move blinking cursor left or  right when programming    NO  water   et days you don t want  DAYS watering to occur    Increase or decrease numbers  when programming       2500000    Quick START    The Quick Start section takes you through the four basic program   ming steps needed to set up automatic watering with the PSC Z     STEP 1  SET TIME AND                                       1  Press                                       SUN    3  Press or Move to hours  minutes     AM PM or 24 hr    or Day of the week     Press    or
3.   os o calurosos   V Establece dos programas completamente diferentes  A y B  para ajustarse a sus  diversas necesidades de riego  por ejemplo  aspersores y goteo   Es como tener dos  controladores    V Puerta con cerradura para resistir vandalismo    V Conecte directamente un sensor de lluvia al controlador  o invalide manualmente el  sensor con s  lo oprimir un bot  n    V Conf  e en la protecci  n contra sobretensi  n transitoria    V Conecte el controlador a una v  lvula maestra de 24 V o al rel   de una bomba           V Tiempo m  ximo de riego  3 horas  59 minutos por estaci  n     Especificaciones                   Voltaje primario de entrada  120  VAC Nominal  60 Hz  Exterior    24 VAC   1A interior      Voltaje de salida de la estacion   24 VAC  0 5 A maximo     Voltaje de salida de la bomba   v  lvula maestra  24 VAC  0 5 A  M  ximo     Tama  o del conducto  Tama  o del  conducto de la corriente primaria   de 1   25 mm  a 11   2     38 mm      V  lvulas por estaci  n  Un m  ximo de  2 solenoides est  ndar     6 solenoides  Hunter de baja corriente     Bater  a opcional  Alkalina de 9 volt     Tama  o del cableado  Como m  ximo    14 AWG     Sensor de lluvia  Mode  interrupci  n        o de    Protecci  n contra sobretensi  n  transitoria  Tipo MOV localizado en  cada estaci  n y en la corriente primaria     El Monitor PSC Z            nnn    El controlador PSC Z viene equipado con un monitor claro y f  cil  de leer  que muestra la hora y el d  a cuando no est   ejec
4.  12 horas  Para ello  mantenga  oprimido el bot  n denominado START TIMES durante 4  segundos  y a continuaci  n introduzca la nueva hora       Los programas A y B tienen diferentes horas de comienzo del riego       Los programas A y B pueden tener distintos periodos de  retraso entre ciclos         Si usted establece la hora de comienzo del riego en O FF  el  programa queda inactivado en su totalidad     Establezca D  as sin Riego                      ee    NO  Oprima die  Para que la pantalla muestre     Se usa para especificar los  d  as en que no desea que  haya riego  Los d  as sin  riego aparecer  n subrayados  Oprima  0   para cambiar la  designaci  n           NO    WATER SUN MON TUE WED THU FRI SAT            Los programas A y B tienen distintos d  as sin riego       Cualquier riego en progreso se completar   incluso si se solapa con un  d  a sin riego  Cualquier riego programado para comenzar en un d  a sin  riego se pospondr   hasta el pr  ximo d  a disponible   No se perder        EJEMPLO  El programa de conservaci  n en su   rea le permite regar  s  lamente los Lunes  Mi  rcoles  y Viernes  Establezca 1 d  a entre riegos   designe el Martes  Jueves  S  bado y Domingo como d  as sin riego     Bot  n de Finalizaci  n Cancelaci  n                            END  Oprima            Para volver a la pantalla principal en cualquier momento  El  controlador graba todas las entradas a medida que usted las realiza       Para cancelar un riego manual  El tiempo de riego que
5.  ambos programas  hasta un m  ximo del 130 por ciento del  tiempo normal  Para ello  oprima 4 tres veces  El pr  ximo mes  usted   puede volver al programa de riego normal oprimiendo   tres veces     Cambio de Programa wuss               CN  Oprimir         Para que la pantalla muestre       STATION rae d          1  La pantalla le indica                d                qu   programa se B            wep              encuentra     El PSC Z puede memorizar dos programas completamente diferentes   A y B  Cada programa puede controlar la misma o diferentes  estaciones  y puede tener distintas horas de comienzo del riego   duraci  n del ciclo  ciclos por d  a e intervalos  d  as entre riegos        Los botones Hora D  a  Ajuste Clim  tico y Lluvia afectan a  ambos programas       Las Horas de Comienzo  D  as sin Riego  y Ajuste del Periodo  de Retraso afectan a cada programa por separado       La hora de comienzo para el programa B se establece  inicialmente en 0 FF  el programa est   desactivado        EI PSC Z tiene un dispositivo que impide el solapamiento de  los programas A y B  Hasta que un programa no termine  no  puede dar comienzo al otro     EJEMPLO  Una vez que se ha programado el riego  usted quiere activar un  ciclo de corta duraci  n en cada estaci  n  Use el programa B para establecer  tiempos de riego de corta duraci  n en cada estaci  n  A continuaci  n   active manualmente el programa B  oprima ALL STATIONS      Cierre del Sistema                            Para 
6.  n  Vea la pg 17     La Secci  n Tres corresponde al COMIENZO R  PIDO  donde se  esquematizan los cuatro pasos b  sicos para programar su PSC Z   Al principio  use esta secci  n para programar riegos autom  ticos  en su PSC Z  Vea la pg 18     La Secci  n Cuatro proporciona una definici  n detallada de cada  bot  n  y del proceso de PROGRAMACI  N  Vea la pg 20     La Secci  n Cinco es una gu  a para la IDENTIFICACI  N DE  PROBLEMAS en el Controlador PSC Z  Vea la pg 25     El Controlador PSC Z de la Serie Profesional de Hunter facilita el  riego de los jardines de nuestros hogares  Hunter goza de una gran  reputaci  n en la industria del riego profesional  debido a sus  dise  os innovadores y a la calidad de sus productos  Ahora puede  encontrar el nombre de Hunter en controladores tras la  introducci  n del PSC Z   que ha sido cuidadosamente dise  ado  para facilitar su uso y conseguir resultados   ptimos  Simplemente  con oprimir un bot  n  usted puede establecer programas de gran  complejidad para cubrir todas sus necesidades de riego     El PSC Z de Hunter le ayudar   a mantener sus jardines en bu  n  estado  al mismo tiempo que le proporcionar   un servicio  sin  problemas  durante a  os  Tanto si se encuentra en su hogar o  lejos de   l  usted puede relajarse y olvidarse del las tediosas  tareas de riego     El PSC Z es tan f  cil de usar  que usted necesitar   revisar este  manual muy pocas veces despu  s de su instalaci  n  Si usted  tienen alguna pregunta acerca de e
7.  resta se pierde       Para detener un riego autom  tico  Oprima este bot  n otra vez para reanudar el riego     NOTA  Si usted detiene un riego autom  tico hasta el final del d  a  el PSC Z  reanudar   el riego en la sigiente hora programada     Activaci  n M anual de una Estaci  n                        Oprima Para que la pantalla muestre     Usado para activar manualmente CRUSH T  un solo ciclo de riego en una  PROGRAMA   p  qu oy  estaci  n  La duraci  n del ciclo TURNS   depende del programa de riego   establecido para esa estaci  n       El riego dar   comienzo 2 segundos despu  s de que usted haya  seleccionado la estaci  n       Usted puede ajustar temporalmente la duraci  n de un ciclo mientras la  estaci  n est   regando  El cambio no afecta a sus programas       EJEMPLO  Usted quiere inspeccionar un nuevo aspersor en la estaci  n 3           Oprima ONE STATION tres veces hasta que la estaci  n 3 aparezca en pantalla   Una vezque comience el riego  ajuste la duraci  n del ciclo a 1 minuto     Activaci  n M anual de un Programa Completo         Oprima Para que la pantalla muestre     H   STATION MANUAL                            AND CYCLES    Se usa para activar manualmente locana D      i  un programa completo  A 0     en M Lr ow  cualquier momento  cada ciclo  de cada estaci  n        Para comenzar con una estaci  n que no sea la 1  oprima  0    0  oprima ALL STATIONS repetidamente       El riego empezar   2 segundos despu  s de que usted haya  seleccionado la esta
8. 940 Diamond Street   San Marcos  California   92069   USA   Tel  619 744 5240    All rights reserved Part No  708977A  Printed in USA on recycled paper LIT 122Z  2 96                
9. AG    Residential Commercial     Irrigation Controller                Owner   s Manual and Vet d               Programming pm amt Reset gene art Ur  Instructions   ete eee ete ee       m 600 2  600 Zi  m 900 Z  900 Zi         m 1200 2  1200 21         m 1600 7                 e Urea     ae                           Hunter          controller    ABOUT THIS MANUAL ENGLISH pages 2 13    The Hunter PSC Z Controlla  Owner s M anual and  Programming Instructions is  presented in two languages   For easy reference  pages in  each section are marked with  a bar as shown to the right     NOTA ACERCA DE ESPANOL p  ginas 14 25    ESTE MANUAL   El manual del propietario y  las instrucciones de  programaci  n del  controlador PSC Z estan a  su disposici  n      dos  idiomas  Para facilitar su  localizaci  n  las p  ginas de  cada seccion est  n  se  aladas por un recuadro  tal y como se muestra a la  derecha     Contents  Introduction                                            SECTION ONE  Operating Features and Specifications                                  SECTION TWO  The PSC Z Display and Keypad                           SECTION THREE  QUA                     Pam i in in ena iras    SECTION FOUR   Programming the Controller                          ee  O Moving About the Display                   ne      SetClock and Day wisest          Set Station Run Time  Cycles  and  Days                      44                              nnn    Set Program Start Times conciernen  Set Non Irrig
10. C Z will again display the error message when the next  automatic watering program is complete           Connecting a Rain Sensor               ee    A rain sensor can be connected to the PSC Z to turn the  controller off when an appropriate amount of rain is measured   The controller display then appears as shown       The sensor connects directly  to the controller  When the  sensor is activated  you can  easily override the sensor  and water manually simply  by pressing ONE STATION or ALL STATIONS        Fur  Lr    SENSOR 3 I          Automatic Test Feature                nn    The PSC Z test feature allows you to quickly test the display and  station outputs       Press the NEXT  LAST  and RAIN OFF buttons at the same time  This  will light the entire display for a quick visual test       Then press the ALL STATIONS button to automatically turn each  station on for 3 seconds  Use a multimeter or solenoid to test each  station s output       Press the END CANCEL button at any time during testing to stop the test   12    TROUBLESHOOTING GUIDE    PROBLEM    Display indicates  irrigation but valve is off    Display is blank    Time of day is blinking    Display reads   SENSOR RAIN OFF     Rain sensor does not  suspend irrigation    Controller was  programmed and now it  doesn t return to the  default program values    Display reads   STATION 1 E rr     CAUSE    Faulty or mis wired  valve    SOLUTION    Check valve and valve  wiring  and valve  common         Faulty pump or pu
11. N TRES  Comienzo R  pido                   enne 18    SECCI  N CUATRO    Programaci  n del Controlador                         e 20  O Movimiento dentro de la Pantalla wuss 20  O Establezca la Hora y el D  a                nene 20  O Establezca el Tiempo de Riego de la Estaci  n    Ciclos    Intervalo wissen 20  O Establezca las Horas de Comienzo del Riego para el   Programa cocina rr rr 21  O Establezca D  as Sin Riego sssrini 21  O Bot  n de Finalizaci  n Cancelaci  n                     22  O Activaci  n Manual de una Estaci  n                             22  O Activaci  n Manual de un Programa Completo              22  O Ajuste del Riego debido a Cambios Clim  ticos              23  O Cambio de Programa                 nn 23  O Cierre del Sistema             nennen 24  O Detecci  n de un Cortocircuito                        ee 24  O                    de un Sensor de                                          24  O Examen Autom  tico                  eene 24    SECCI  N CINCO  Gu  a para la Identificaci  n de Problemas                           25                           a    Muchas gracias por haber adquirido el Controlador PSC Z de las  Industrias Hunter  Para ayudarle a familiarizarse con el  funcionamiento del PSC Z  hemos dividido este manual en cinco  secciones faciles de entender     La Secci  n Uno enumera las principales CARACTER  STICAS DE  FUNCIONAMIENTO del PSC Z  Vea la pg 16     La Secci  n Dos describe la PANTALLA DEL PSC Z y el  funcionamiento de cada bot 
12. O                     i WATER  1  Oprima                              WATER SUN MON TUE WED THU FRI SAT       3  Oprima 0 Para cambiar de dia     Oprima 0  0    Selecciona los dias sin    riego  subrayado      PROGRAMACION DEL CONTROLADOR PSC Z    Movimiento dentro de la Pantalla                           Use los cuatro botones situados en el centro del panel de control  para desplazarse dentro de la pantalla             3               Oprima los botones sombreados              los botones sombreados  para desplazarse de secci  n en          modificar el valor  Secci  n  La secci  n activada se intermitente  o para   mostrar   intermitente  seleccionar d  as     Establezca la Hora y el Dia                        1 Para que la pantalla muestre             HAM  SUN         Establezca la hora y el dia  antes de establecer los  horarios de riego      Establezca la hora en la modalidad AM  PM 6 24 horas        Establezca el Tiempo de Riego de la Estaci  n   Cidos e Intervalos sss vis eia aa iss    Oprima              que en la pantalla aparezca     STATION pu             rh owl           PROGRAM    11 I  1       Usted puede establecer la  siguiente informaci  n en  cada estaci  n     I  I  1 DAYS    CYCLE TIME APART    NEXT WATER WED         Duraci  n del ciclo     N  mero de   D  as entre   desde 1 min  ciclos por d  a riegos  a 3 hrs   59 min    de 1a 14   de 1a 14       EI PSC Z espera un m  nimo de 30 min  entre ciclos para permitir  que el agua penetre en la tierra  Para cam
13. ation Days    enne  The End Cancel Button                                  Manually Run a Single Station                                  Manually Run an Entire Program    ssis  Adjust Watering for Seasonal Changes                       Switching Programs                   enne  Turning Off the System                  ee  Short Detection wissen    Connecting a Rain Sensor sssr    O O O OO O O        Q    Automatic Test Feature wwii    SECTION FIVE  Troubleshooting Guide                          nn     Introduction A O    Thank you for purchasing Hunter Industries Incorporated PSC Z  Controller  To help you become accustomed to the PSC Z s  operation  we have divided this manual into five easy to  understand sections     Section One lists the key OPERATING FEATURES of the PSC Z   See page 4     Section Two describes the PSC Z DISPLAY and gives you a quick  definition of each button s operation  See page 5     Section Three is the QUICK START section  outlining the four  basic steps in programming your PSC Z  Use this section to  initially set up your PSC Z for automatic watering  See page 6     Section Four gives detailed definitions of each button  and  describes details of PROGRAMMING your PSC Z controller   See page 8     Section Five is a guide to TROUBLESHOOTING the PSC Z  controller  See page 13     The Hunter PSC Z Professional Series Controller makes home  landscape irrigation easy and fun  Hunter is well known in the  professional irrigation industry for innovative de
14. biar el periodo de  retraso autom  tico entre los ciclos de cada programa  mantenga  oprimido el bot  n denominado  START TIMES  durante 4 segs       La duraci  n del ciclo debe ser          en las estaciones que no se utilicen       Usted puede modificar la informnaci  n de una estaci  n en  cualquier momento  incluso cuando se est   regando       EI PSC Z viene equipado con un horario de riego que entrar   en  vigor si usted no programa su propio horario de riego  o si hay un  corte de corriente  no hay bater  a  y la capacidad de  almacenamiento interno se ha consumido  despu  s de 10 horas  sin corriente o sin bater  a de apoyo      Hora de          Duracion Ciclos Dias Entre Comienzo Retraso   Programa del Ciclo por Dia Riegos del Ciclo del Ciclo  A 10 min  1 1 lam 30 min    B 1 min  1 1 0 FF 30 min        Establezca las Horas de Comienzo del Riego para  el PROG AINA ainia    Oprima        Para que la pantalla muestre                rit    La hora de comienzo es la  hora a la que el ciclo de riego  da comienzo  El PSC Z  calcula la hora de comienzo  de cada ciclo del programa en base a la hora de comienzo que  usted establece       El periodo de retraso entre ciclos  establecido inicialmente en  el controlador  es de un m  nimo de 30 minutos     START TIME    PROGRAM A               Usted puede aumentar el  periodo de retraso entre  los ciclos de cada                         PROGRAMA            DELAY CYCLE TIME       programa en incrementos  de 1 hora  hasta un maximo de
15. ci  n       Mientras el programa est   en funcionamiento  usted puede ajustar  temporalmente la duraci  n del ciclo en cualquier estaci  n  El  cambio no afecta a sus programas       El programa B se establece inicialmente como un programa de  prueba  Active el programa B manualmente para encender cada  estaci  n durante un minuto     EJEMPLO  Ha hecho un tiempo seco y c  lido  Usted quiere activar  el programa completo esta noche sin tener que cambiar el horario  de riego programado  Oprima ALL STATIONS           Ajuste del Riego debido a Cambios Clim  ticos            Oprima             que la pantalla muestre   SEASONAL STATION       CYCLES     ADJUST l Fa anra ew     PROGRAM A 11 I od 1 mess 3   CYCLE TIME APART      NEXTWATER WED              Se usa para aumentar o disminuir la cantidad de agua aplicada en  todas las estaciones          La barra indica un cambio  La frecuencia de riego y el n  mero de  ciclos permanecen igual  S  lo var  a la duraci  n del ciclo  Este ajuste  afecta al programa A y B       La duraci  n del ciclo var  a en incrementos del 1096  desde un 1096  hasta un 15096       Eltiempo se redondea al minuto m  s pr  ximo  la duraci  n del ciclo  no puede ser inferior a 1 minuto       Paraobservar el cambio realizado en la duraci  n del ciclo   seleccione la estaci  n antes de ajustar la duraci  n del ciclo     EJEMPLO  Ha sido un mes excepcionalmente c  lido y seco  En vez   de reprogramar el riego para un s  lo mes  usted puede aumentar el   riego  en
16. cortocircuitos en el  cableado de la estaci  n       25    FCC Notice    This controller generates radio frequency energy and may cause interference to radio  and television reception  It has been type tested and found to comply with the limits  for a Class    computing device in accordance with the specifications in Subpart J of  Part 15 of FCC Rules  which are designed to provide reasonable protection against  such interference in a residential installation  However  there is no guarantee that  interference will not occur in a particular installation  If this equipment does cause  interference to radio or television reception  which can be determined by turning the  equipment off and on  the user is encouraged to try to correct the interference by one  or more of the following measures       Reorient the receiving antenna       Move the controller away from the receiver          Plug the controller into a different outlet so that controller and receiver         on different branch circuits     If necessary  the user should consult the dealer or an experienced radio television  technician for additional suggestions  The user may find the following booklet  prepared by the Federal Communications Commission helpful   How to Identify and  Resolve Radio TV Interference Problems   This booklet is available from the U S   Government Printing Office  Washington  D C   Stock No  004 000 00345 4     Price    2 00 postpaid     Hunter    Copyright 1993 Hunter Industries Incorporated  1
17. efinitely     V Set days on which no watering will occur     V Manually run an entire program or a single station at any time     V At the touch of a button  make seasonal adjustments for wet or    dry spells     V Set up two completely different programs  A and B  to meet  diverse watering needs  drip and spray  for example   It s like    having two controllers     V Lock cover to resist tampering     V Connect a rain sensor directly to the controller  or manually  override the sensor simply by pressing a button     V Rely on proven superior surge protection     V Connect to a 24V master valve or pump relay     V Maximum run time  3 hours  59 minutes per station     S peaficationis tna     Primary input voltage  120 VAC  Nominal  60 Hz  Outdoor   24  VAC   1A indoor      Station output voltage  24 VAC   0 54 maximum     Pump master valve output  voltage  24 VAC  0 4A maximum     Conduit size  Primary power  conduit size  1 2   13 mm   field  wiring conduit size  1   25 mm   to 1 2   38 mm      Valves per station  Maximum 2  standard draw solenoids or 6  Hunter low current solenoids     Optional battery  9 volt  alkaline     Field wiring size  14 AWG  maximum     Rain sensor  Interrupt type     Surge protection  MOV type on  each station and primary power     The PSC Z Display                           The PSC Z s clear  easy to read display shows time and day when the  controller is idle  By pressing the Station button  you can check the  watering schedule for any station   
18. et for    cycle delay time of at least 30  minutes between each cycle          You can increase the cycle  delay time for either program  in 1 hour steps  up to 12           PROGRAM    1 Ir 111    DELAY CYCLE TIME       hours  by holding down  START TIMES for 4 seconds  then entering a new time       Programs    and B have different start times     Programs A and B can have different cycle delay times     Setting the start time to 0 FF disables an entire program     Set Non Irrigation Days                ne    NO  Press ie  To display     Use to specify days on which  no watering should occur   Underline indicates a No  Water Day  Press   or   to change designation        NO  WATER SUN MON TUE WED THU FRI SAT            Programs A and B have separate No Water Days       Any irrigation in progress will complete  even if it overlaps into a  No Water Day  Any watering scheduled to start on a No Water Day  will be postponed until the next available day   It will not be lost      water Monday  Wednesday and Friday only  Set Days Apart to 1       EXAMPLE  Water rationing in your area dictates that you can  make Tuesday  Thursday  Saturday and Sunday No Water Days     The End Cancel Button                   nn    END  Press                     Return to the main display at any time  The controller saves all entries  as you make them       Cancel manual watering  All remaining time is lost     Pause automatic watering  Press again to restart     NOTE  If you leave automatic watering 
19. ezas  defectuosas     Verifique la  existencia de  corriente y el  cableado    Oprima cualquier  bot  n       Se ha producido un  apag  n por un largo  periodo de tiempo y  el sistema de apoyo  incorporado se ha  agotado    Si usted no est    utilizando un sensor  de lluvia  no existe  puente entre las  terminales del sensor  0 el puente est   suelto    Reprograme el  controlador    Reconecte el puente  entre las terminales  del sensor de lluvia  en el bloque de  erminales       Si usted est   usando un  sensor de lluvia  El  Sensor ha sido activado  por humedad  o se  encuentra trabado en  posici  n abierta    El puente de  conecci  n entre las  terminales del  sensor de lluvia  sigue desconectado    Verifique el funciona   miento del sensor de  luvia  Reempl  celo si  es necesario  reconecte el puente  hasta que se instale el  nuevo sensor de lluvia        Desconecte el  puente  el puente  debe estar  desconectado  cuando se usa un  sensor de lluvia          Sensor de lluvia  defectuoso o  conecci  n incorrecta    Esto se debe al  sistema de apoyo  incorporado    Se produjo un error  la   ltima vez que se  activ   la estaci  n  indicada    Verifique el funciona   miento del sensor y  las conecciones       Para que el controlador  vuelva al programa  inicial  introduzca un  destornillador dentro  de la ranura   denominada    reset      localizada cerca del  bloque de terminales    Pulse END CANCEL  para eliminar el  mensaje de error e  inspeccione el sistema  para detectar  
20. haya riego proceso de programaci  n  17    Comienzo RApPIDO    La secci  n de comienzo rapido le presentar   los cuatro pasos  b  sicos para la programaci  n de riegos autom  ticos en el PSC Z     PASO 1  ESTABLEZCA LA HORA Y EL                               1  Oprima w                                   SUN    3  Oprima 0 Cambia a horas y minutos     AM PM 6 24 hr    o D  a de la semana     Oprima    0    Modifica la informacion     PASO 2  ESTABLEZCA O CAMBIE LA INFORMACION  DE LA ESTACI  N sssr          1  Oprima STATION    Y                STATION zm                     2     ana RR    2       PROSRAMA     ttt yy 1    CYCLE TIME D    NEXTWATER WED  3  Oprima 0 Cambia a duraci  n del  ciclo  ciclos por d  a d  as  entre riegos  n  mero de  la estaci  n   Oprima      0    Modifica la informacion    o el n  mero de la estaci  n     4  La duraci  n del ciclo debe ser cero en las estaciones que no se utilicen     Durante 4 segs  para  5  Oprima TIMES ajustar el periodo de   retraso entre ciclos    opcional      6  Oprima A 0 e Ajusta el periodo de  retraso  de 30 min  a  12 hrs  para A o B      Comienzo R  PIDO    PASO 3  ESTABLEZCA LAS HORAS DE COMIENZO DEL    1  Oprima                                PROGRAM A V EEUU                       START TIME         3  Oprima 0 Cambia de horas       minutos     Oprima 0  0    Se establecer   la hora de B    comienzo del riego  Se  establece un solo ciclo  por programa  El PSC Z  calcula el resto     PASO 4  ESTABLEZCA LOS DIAS SIN RIEG
21. mp  relay if used    No AC power and no  backup battery  installed  or dead  battery     Unit is initially  powered up    Extended power  outage has occurred  and built in backup  period has expired    f you are not using a  rain sensor    The jumper between  he sensor terminal is  missing or loose    Check pump and  pump relay  Replace  if defective     Verify AC power and  wiring     Press any button    Reprogram controller    Reconnect the jumper  between the rain  sensor terminals of  the terminal block       f you are using a rain  Sensor    he sensor has been  activated by moisture  or is stuck  open        umper between  sensor terminals is  still connected    Verify operation of  rain sensor  Replace  if defective  reinstall  jumper until new rain  sensor is installed     Disconnect the jumper   jumper should be  disconnected when  using a rain sensor        Rain sensor is  defective or mis   wired    This is dueto the  built in backup    An error occurred the  last time station tried  to water    Verify operation of  sensor and proper  wiring    To reset the  controller to default  program values   insert screw driver  into the reset slot on  the faceplate  near  the terminal block     Press END CANCEL  to remove error  message and check  for shorts in station  field wiring       Contenido    Introducci  n cocino 15    SECCI  N UNO  Caracter  sticas de Funcionamiento y Especificaciones         16    SECCI  N DOS    El Monitor y el Panel del PSC Z sssrinin 17  SECCI  
22. paused until the end of the day   the PSC Z will resume watering at its next scheduled time     Manually Run a Single Station                              Press To display     STATION MANUAL REMAINING TIME    Lg  n dg      PROGRAM A        1 1 l  RUNNING za S             Use to manually run a single watering cycle at one station  The  cycle time depends on the program you ve set up for that station       Watering begins 2 seconds after you select the station     e You can temporarily adjust a cycle time while a station is  watering  The change does not affect your programs     ONE STATION three times to display Station 3  When watering    EXAMPLE  You want to test a new sprinkler at Station 3  Press  starts  adjust the cycle time to 1 minute     Manually Run an Entire Program                          Press            display     STATION MANUAL     REMAININGTIME AND CYCLES    1    PA n dg                        LI   1 11  RUNNING             Use to manually run an entire program at any time  either A or B   every cycle at every station        To start from a station other than 1  press   or    or press ALL  STATIONS repeatedly       Watering begins 2 seconds after you select the station       While the program is running  you can temporarily adjust the cycle  time for any station  The change does not affect your programs       Program B is initially set as a test program  Manually run Program  B to cycle once through each station for one minute     EXAMPLE  It s been hot and d
23. que la pantalla muestre       Cierra autom  ticamente RAIN   ri  FE  ambos programas  A y B  m        Oprima RAIN OFF otra vez o END CANCEL  para reanudar su funcionamiento       Enla modalidad RAIN OFF  usted puede regar manualmente   oprima ONE STATION  o ALL STATIONS   El sistema permanecer    cerrado despu  s de que el riego manual haya terminado       Usted tambi  n puede oprimir RAIN OFF para detener un riego  manual  el tiempo que resta se pierde               Detecci  n de un Cortocircuito                       El PSC Z ha sido dise  ado con un dispositivo para detectar  cortocircuitos  Si se produce un cortocircuito en el cableado de  una v  lvula  el PSC Z lo detectar   y continuar   regando el resto  de las estaciones  Una vez que el riego autom  tico haya  terminado  la pantalla le indicar   el problema          Para volver a la pantalla STATION E  de la Hora y el D  a      Er    oprima END CANCEL  E 1         Para programar el  controlador  oprimalos botones que usar  a normalmente en el  proceso de programaci  n  El PSC Z mostrar   otra vez el  mensaje de error cuando el siguiente riego autom  tico finalice     Conecci  n de un Sensor de Lluvia                        Se puede conectar un sensor de lluvia al PSC Z para apagar el  controlador cuando una cantidad apropiada de lluvia haya sido  medida  La pantalla del controlador mostrar   el siguiente mensaje       El sensor se conecta  directamente al controlador   Cuando el sensor se activa  usted  puede invalida
24. rlo f  cilmente y  regar manualmente   Simplemente debe oprimir ONE STATION o ALL STATIONS        Far    d    SENSOR 1                i       Examen Autom  tico           Esta caracter  stica del PSC Z le permite examinar r  pidamente la  pantalla y el voltaje de salida de la estaci  n       Oprimalos botones NEXT  LAST  y RAIN OFF al mismo tiempo   Este procedimiento iluminar   completamente la pantalla  y le  permitir   realizar un examen visual r  pido       Acontinuaci  n  oprimael bot  n denominado ALL STATIONS  para activar autom  ticamente cada estaci  n durante 3  segundos  Use un medidor de voltaje o un solenoide para  examinar el voltaje de salida de cada estaci  n       Oprimael bot  n denominado END CANCEL para detener la    22 prueba en cualquier momento     GUIA PARA LA IDENTIFICACION DE PROBLEMAS    PROBLEMA    Monitor indica riego  pero la valvula esta  cerrada    El monitor est   en  blanco    La hora se muestra  intermitente    El monitor indica   SENSOR RAIN OFF     El sensor de lluvia no  cancela el riego    El controlador fu    programado y ahora no  vuelve al programa  inicial    El Monitor indica   STATION 1 E rr     CAUSA      V  lvula defectuosa o  mal conectada    SOLUCION    Inspeccione la v  lvula y  el cableado  incluyendo  el cable com  n        Bomba o rel   de la  bomba defectuoso    No hay corriente ni  bater  a de apoyo  o  bater  a gastada     Activaci  n inicial de  la unidad    Inspeccione la bomba  yel rel   de la bomba   Reemplace las pi
25. rt     The Time Day  Seasonal Adjust and Rain buttons apply to both  programs     Start Times  No Water Days  and adjusted Cycle Delay apply to  each program     Program B s Start Time is initially set to 0 FF  program is off      The PSC Z avoids program overlaps between A and B by waiting for    one program to complete before beginning the other     EXAMPLE  After setting up the system  you want to run a short  cycle on every station  Use Program B to set short run times for  each station  then manually run Program B  press ALL STATIONS      11    Turning Off the System                  eee    Press To display          rh  RAIN Lr dg          Turns off automatic operation  for both programs  A and B       Press RAIN OFF again  or END CANCEL  to restart operation        n Rain Off mode  you can still water manually  press ONE STATION or ALL  STATIONS   System will remain off after manual watering is complete       You can also press RAIN OFF to stop manual watering  any  remaining time is lost            Short Detection oon Cone ione na                           The PSC Z is designed with electronic short detection  If a valve  wire is shorted  the PSC Z will detect the short then continue  watering all other stations  When automatic watering is complete   the display will show the problem       To return to the normal STATION    Time and Day display        press END CANCEL        To program the controller   press the buttons you would normally use for programming  The    PS
26. ry  You want to run an entire extra  program this evening without changing scheduled watering  Press  ALL STATIONS     Adjust Watering for Seasonal                                  Press    To display        STATION       Setas  I ma        SEASONAL  ADJUST             l      PROGRAM          Days  CYCLE TIME    APART   NEXT WATER WED          Use to increase or decrease the amount of water applied to all stations     Bar indicates change  Watering frequency and number of cycles  remain the same  Only cycle time changes  Affects programs A and B     Cycle times change in 10  steps  from 10  to 150      Time is rounded to the nearest whole minute  cycle time cannot be  reduced to less than one minute     To observe the change in cycle time  select the station before  adjusting the cycle time     EXAMPLE  It   s been an exceptionally hot and dry month  You don t  want to reset your programs for a single month  Instead  increase all  watering  both programs  to 130 percent of normal by pressing  2   three times  Next month  return to normal watering by pressing     three times     Switching Programs                  nnn    Press To display        a       STATION        GES  Display indicates x  A     n         which program you                       wep      APAR    are in           The PSC Z can store two completely separate programs  A and B   Each program can control the same or different stations  and can  have a different start time  cycle times  cycles per day and days apa
27. signs and quality  products  Now the Hunter name is available in controllers with  the PSC Z   carefully engineered for simple use and sophisticated  results  With the touch of a button  you can set up complex  programs that meet all your watering needs     The Hunter PSC Z will help you maintain a lush  beautiful landscape  while providing years of trouble free service  Whether you re at  home or away  you can relax and forget tedious watering chores     The PSC Z is so easy to use that you ll need this Owner s Manual  very little after installation  If you do have a question about your  controller  refer to this booklet  or to the abbreviated  instructions inside  the door  If you still  have a question  you  can call Hunter s  customer service  line at     619  471 9010  between 7 AM and   6 PM Pacific Time        Operating Features           V Independently assign each station   s cycle lengths  number of  cycles per day  and days between watering     V Cycle each station to water up to 28 times per day  14 times per    program      V No fuse needed  electronic short circuit detection warns of a  short  then continues to next station     V No battery needed  programs stored for up to 10 continuous  hours  With optional battery  programs saved for up to 7 months     V Adjust delay time between watering cycles  from 30 min  to    12 hrs   in one hour steps     V With one touch  pause automatic watering  then restart     V Press the Rain button to stop automatic watering ind
28. ste controlador  consulte este  manual o las instrucciones   simplificadas que  encontrar   en la   puerta del controlador   Si no logra aclarar su  duda  por favor llame   a la oficina del   servicio al cliente de  Hunter  al tel  fono    619  471 9010  Ingl  s   entre 7 AM y 6 PM Hora  del Pac  fico        Caracter  sticas de                                                      V Asigna independientemente a cada estaci    por d  a  y d  as entre riegos     el tiempo de riego  el n  mero de cidos    V Cada estaci  n puede activarse un m  ximo de 28 veces al d  a  14 veces por programa      V No se necesita fusible  el reloj detecta el  ctr        camente la existencia de un cortocircuito     adverte al usuario de esta situaci  n y luego continua con la siguiente estaci  n     V No senecesita bater  a  el programa queda memorizado durante un m  ximo de 10    horas  Se puede incorporar una bater  a opci                           que retiene los programas durante 7             meses    V Ajusta el periodo de retraso entre ciclos de riego desde 30 minutos hasta 12 horas  en  incrementos de una hora    V Con s  lo tocar un bot  n detiene el riego autom  tico y posteriormente puede  reanudarlo    v  Oprima el bot  n de lluvia para detener el riego indefinidamente    V Establece los d  as en los que no desea que haya riego    V En cualquier momento activa manualmente un programa completo o una estaci  n    V Con s  lo tocar un bot  n realiza ajustes clim  ticos debido a periodos fr
29. tting up watering schedules       Set time to AM  PM  or 24 hour                                      Set Station Run Time  Cycles  and Days Apart          Press     To display     STATION CYCLES           ee      ni  PROGRAMA      qup   pays       CYcLETIME             NEXTWATER WED       For each station           you can set      Cycle length   Number of   Days between   from 1 min  cycles per day waterings  to 3 hrs   59 min    from 1 to 14   from 1 to 14       The PSC Z waits at least 30 min  between cycles to allow water to soak  into the soil  To change the automatic cycle delay time for either program   hold down START TIMES for 4 secs       Set all cycle times to zero on unused stations     You can enter new station settings at any time  even while water is running       ThePSC Z has a supplied schedule that it will run if you do not set one  up  or if power is lost  there is no battery  and the internal power storage  capacity is exhausted  after 10 hours without power or backup battery         Cycle Cycles Days Start Cycle  Program Time per Day Apart Time Delay  A 10 min  1 1 lam 30 min        B lmin  1 1 O FF 30 min        Set Program Start Times                                 Press       To display     START TIME  The Start Time is the time the  entire watering cycle begins   The PSC Z calculates the start  time for each cycle in the  program based on the start time you enter        LAA  PROGRAM A tl LI        1                      The controller is initially s
30. utando  ninguna orden  Con s  lo oprimir el bot  n denominado Station   usted puede revisar el horario de riego de cualquier estaci  n     No  de ciclos por d  a  14  por programa  un total  2 programas independientes  de 28 por estaci  n   AyB    Duraci  n del ciclo hasta un m  ximo  N  mero de la estaci  n de 3 horas  59 minutos            STATION    i    CYCLES    Pk d gd         Indicador                        de ajuste _        Ld ILI DAYS    clim  tico       CYCLE TIME APART    m       NEXTWATER WED    Proximo dia Dias entre riegos  hasta  de riego un maximo de 14  B    Descripci  n de los botones del panel                             Cambia del Programa     Aumenta    disminuye al B    SEASONAL     ADJUST todos los tiempos de    riego Activa una estaci  n  manualmente    Detiene el riego durante    TIMEW Establece la hora y el un ciclo autom  tico  DAY d  a  AM PM 6 24 horas   Cancela un riego manual    Devuelve la hora y el d  a    ala pantalla durante el  proceso de programaci  n    Programa una estaci  n Activa un programa   STATION ds conseguir un riego completo  incluyendo   p seg 9 todos los ciclos  automatico    Detiene    reanuda el  riego automatico  Establece la hora ala programado    START  SMES que el Programa A y o B  comenzar  n el riego       E    Desplaza el cursor  intermitente a la derecha  o izquierda durante el  proceso de programaci  n  AA Establece los d  as en Aumenta o disminuye un  que usted no desea que An  DAYS valor num  rico durante el    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Installations  fonds bijouterie Jeannot  ONKYO TX-NR838  Solid-State Memory Camcorder  Lexmark Z25 Printer User Manual  Installation and Service Manual Fleet AC Level 2  User's Manual  Philips Remote control for micro system CRP637  ac1 laser de canalisations manuel d`utilisation  Pharmaceutical Regulatory Information System (PRISM)    Copyright © All rights reserved. 
   Failed to retrieve file