1. Touch nSeal St rm Bond ROOEMMILEVADHESIVE Application Instructions Important For professional use only Read all enclosed instructions and cautions carefully prior to use Always wear personal protective equipment refer to the enclosed Safe Use Storage and Handling guide for detailed recommendations Storm Bond is temperature sensitive Failure to follow procedures and temperature guidelines may result in poor performance and may affect foam quality Touch n Seal Storm Bond Roof Tile Adhesive polyurethane foam from Convenience Products is designed for professional use with approved flat low medium and high profile tile systems Section 1 Preparation and Set Up Application area should be clean dry free of oil grease debris and well ventilated Check expiration date on carton to ensure product is current Chemical contents must be brought to a temperature between 70 90 F 21 32 C before and during use Depending upon environmental conditions this could take 36 to 72 hours at room temperature Application in higher or lower temperatures may alter set up time cure time yield and reduce overall adhesive performance 23 Cylinder For best results ensure that chemical ambient and substrate temperatures are 70 90 F 21 32 C before and during use Remove cylinder instructions and accessories from carton Read instructions Attach hose to bottom of foam adhesive applicator
2. Dispense un cord n de adhesivo de 3 4 de ancho x 8 de largo en el lado del enganche inferior a aproximadamente 3 desde la cabeza de la teja Drawing 2 Concrete Tile Low Medium Profile Gr fico 2 Teja De Hormig n Perfil Bajo Medio TOUCH N SEAL STORM BOND ROOF TILE ADHESIVE PLACEMENT DETAIL DOUBLE BEAD SYSTEM DETALLE DE COLOCACI N DEL ADHESIVO PARA TEJAS DE TECHO TOUCH N SEAL STORM BOND SISTEMA DE DOBLE CORD N Apply 3 4 W x 10 L adhesive bead directly onto head lap area of preceeding course on the overlock side of tile Aplique un cord n de 3 4 de ancho x 10 de largo de adhesivo directamente sobre la capa superior de la hilera precedente en el lado de enganche superior de la teja OXIDO DOLO Vj LEY 3 Headlap Monta 3 lly hy S Overlock Enganche superior Dispense 1 1 4 W x 10 L adhesive bead under valley of tile directly opposite underlock approximately 3 from head end of underlying tile Dispense un cord n de adhesivo de 1 1 4 de ancho x 10 de largo debajo de la limahoya de la teja directamente opuesta al enganche inferior a aproximadamente 3 de la cabeza de la teja subyacente S Underlock E Enganche inferior Drawing 3 Concrete Tile High Profile Gr fico 3 Teja De Hormig n Perfil Alto TOUCH N SEAL STORM BOND ROOF TILE ADHESIVE PLACEMENT DETAIL DOUBLE BEAD SYSTEM DETALLE DE COLOCACION DEL ADHESIVO PARA TEJAS DE TECHO TOUCH N SEAL S
3. 813 248 0573 For All Concrete and Clay Tile Application Low Flat Profile Low Medium Profile High Profile Two Piece Barrel Profile For areas and sections of the Roof System not covered by these instructions please refer to the FRSA TRI Concrete and Clay Roof Tile Installation Manual 1 For pitches above 6 12 up to and 2 For pitches above 7 12 nail every including 7 12 nail every third 3rd tile tile in addition to adhesive or use in every fifth 5th course in addition to horizontal batten strips in addition to the adhesive Horizontal batten strips the adhesive may need to be installed depending upon the roof pitch and other attributes of the roof 3 Check local building code for additional nailing requirements Aplicaci n de teja de perfil bajo plano bajo mediano alto tipo barril de dos piezas Para zonas y secciones del Sistema de techos no cubiertas por estas instrucciones por favor consulte el Manual de Instalaci n de Tejas de Cemento y Cer mica para Techo de la FRSA TRI 1 Para pendientes de m s de 6 12 hasta e incluyendo 7 12 clave cada tercera teja en cada quinta hilera adem s de usar el adhesivo Podr a ser necesario usar listones horizontales dependiendo de la pendiente del techo y otras caracter sticas del techo 2 Para pendientes de m s de 7 12 clave cada teja adem s de usar el adhesivo o use listones horizontales adem s del adhesivo 3 Consulte con el C digo de Construcciones lo
4. Code approved adhesive over mechanical attachment see note below 7 Distance between top of ridge board and bottom of tile must be equal or less than 1 for proper adhesion Trim Tile Approved weather blocking Ridge hip nailer of sufficient height to maintain an even plane of trim tiles Ridge riser bracket Heavy gauge galvanized steel or other metal securely fasten per bracket manufacturer instructions Roof Deck Y lt lt Underlayment Openings at hips ridges and head walls including chimneys skylights solar panels and downslope horizontal abutments shall be fitted with weather blocking material to keep water on the surface of the field tile Other methods approved by local building official will be allowed Wrapping of nailer board is optional except with the use of mortar All tile profiles Field Tile Drawing 11 1 2 3 4 5 1 Revestimiento de caballete cumbrera Sellador sensible a la presi n u otro sistema en seco aprobado para caballete y cumbrera 3Revestimiento para teja 4Lamina asf ltica 5Clavadera Plataforma de madera contrachapada 7 Adhesivo aprobado por el c digo sobre la fijaci n mec nica 8 Aristero Distancia entre la parte superior de la viga de cumbrera y parte inferior de la teja debe ser igual o inferior a 1 para una adhesi n adecuada Protecci n contra las inclemencias del tiempo aprobada 1 Clavadera para cumbrera ca
5. aproved pre bagged mortar is allowed Adhesive used to attach tile Distance between top of ridge board and bottom of tile must be equal to or less than 1 for proper adhesion Embed hip ridge tile into mortar or pack with mortar and point to match tile finish Drawing 8 Adhesive set Hip and Ridge Tile using Mortar as a Weather Block Coloque la teja de caballete y cumbrera con adhesivo y usando mortero como protecci n contra las inclemencias del tiempo Adhesive Attachment Structural support according to Fijaci n con Adhesivo FSRSA RTI manual or the HVHZ of the FBC metal shown Embed tile into mortar bed both sides of hip ridge or pack mortar into void after hip and ridge tiles are installed and adhesive has cured Point mortar to match tile finish Tile overlap Drawing 9 Attaching Hip Ridge Tile with Adhesive Using Mortar as Weather Blocking Coloque la teja de caballete y cumbrera con adhesivo y usando mortero como protecci n contra las inclemencias del tiempo 1El mortero premezclado o mezclado en el lugar se puede usar s lo en los lugares donde se lo usa como protecci n contra las inclemencias del tiempo Cuando se usa como agregado de estructura s lo se puede usar mortero premezclado aprobado por la FBC 2 Empotre la teja de caballete y cumbrera en el mortero o ll nela de mortero y busque una terminaci n similar a la teja 3Para pendientes mayores a 7 12
6. ancho x 8 de largo en el lado del enganche inferior a aproximadamente 3 desde la cabeza de la teja Drawing 5 Clay Tile Low Profile Gr fico 5 Teja De Cer mica Perfil Bajo TOUCH N SEAL STORM BOND ROOF TILE ADHESIVE PLACEMENT DETAIL DOUBLE BEAD SYSTEM DETALLE DE COLOCACION DEL ADHESIVO PARA TEJAS DE TECHO TOUCH N SEAL STORM BOND SISTEMA DE DOBLE CORDON Apply 1 2 W x 8 L adhesive bead directly onto headlap area of preceeding course on the overlock side of tile Aplique un cord n de adhesivo de 1 2 de ancho x 8 de largo directamente sobre la monta de la hilera precedente en el lado del enganche superior de la teja 3 Headlap Monta 3 Dispense 3 4 W x 10 L underlock side adhesive bead approximately 3 from head end of underlying tile Dispense un cordon de adhesivo de 3 4 de ancho x 10 de largo en el lado del enganche inferior a aproximadamente 3 desde la cabeza de la teja inferior Drawing 6 Clay Tile High Profile S Tile Gr fico 6 Teja De Cer mica Perfil Alto Teja S TOUCH N SEAL STORM BOND ROOF TILE ADHESIVE PLACEMENT DETAIL DOUBLE BEAD SYSTEM DETALLE DE COLOCACI N DEL ADHESIVO PARA TEJAS DE TECHO TOUCH N SEAL STORM BOND SISTEMA DE DOBLE CORD N Apply 1 2 W x 8 L adhesive bead directly onto headlap 2 1 2 Headlap area of preceding course on the overlock side of tile Monta 2 1 2 F Aplique un cord n de adhesivo de 1 2 de ancho x 8 de largo
7. fijela con un clavo o un tornillo 4El adhesivo se usa para fijar la teja y dar soporte estructural 5 Para pendientes mayores a 7 12 fijela con un clavo o un tornillo para dar soporte estructural Soporte estructural seg n el manual de FSRSA RTI o el HVHZ del FBC se muestra el metal 7 Empotre la teja de forma que haya mortero en ambos lados del caballete cumbrera o rellene con mortero despu s de que se instalaron las tejas de caballete y cumbrera y se cur el adhesivo 8 Trabaje el mortero para lograr una terminaci n similar a la teja 8 Solapamiento de la teja 10 Opcional Instale adhesivo aprobado por el c digo en los solapamientos de las tejas caballete cumbrera 1 Instale adhesivo aprobado por el c digo sobre el soporte estructural seg n est aprobado el producto del fabricante o el HVHZ de la FBC Install code approved adhesive on top of structural support according to adhesive manufacturer s product approval or the HVHZ of the FBC Optional Install code approved adhesive at hip ridge tile overlaps For slopes greater than 7 12 fasten with a nail or screw to structural support Hip and Ridge Tile Installation For Drawings 1 2 amp 4 Instalaci n de tejas de caballete y cumbrera para Gr ficos 1 2 amp 4 Hip Ridge tile Nailer board Field tile a Pressure sensitive sealer strip EZ or other approved dry hip 4 ridge system Underlayment Plywood deck Drawing 10
8. Attach applicator hose assembly to cylinder Tighten with wrench Refer to Drawing 12 Do not pull lift adhesive cylinder by hose Always dispense Storm Bond with chemical cylinder in an upright position mb wo nm PS 24 oz Aerosol Can mb For best results ensure that chemical ambient and substrate temperatures are 70 90 F 21 32 C before and during use Read instructions Remove aerosol can cap Attach straw to trigger adaptor Screw adaptor onto can valve Section 2 Application Shake cylinder for 30 seconds Fully open the valve on tank counterclockwise until resistance is felt Purge air from the chemical hose by aiming the Storm Bond applicator into a waste receptacle and activating the applicator trigger Adjust output rate by turning the brass knurl towards the front of the applicator to increase output or back towards the handle of the applicator to reduce the flow rate Press trigger to test adhesive flow rate on scrap material first Hold cylinder upright by hand or store position upright behind a stack of tile Depress applicator trigger and apply Storm Bond adhesive according to the patterns and bead weights shown in the attached drawings All tiles must be set in adhesive within 4 minutes of adhesive application 24 oz Aerosol Can af w N 23 Cylinder aon Ja NX O a co Shake aerosol can vigorously for 30 seconds Invert can and activate tri
9. GE TILE INSTALLATION TILE TYPE INSTALLATION RIDGE BOARD ADHESIVE BEAD SIZE HEAD LAP ADHESIVE BEAD SIZE DRAWING NUMBER FLAT LOW PROFILE 10 11 1 1 2 wide by 1 1 2 high by 12 long minimum 1 wide by 1 high by 4 long minimum CONCRETE LOW MEDIUM PROFILE 10 11 1 1 2 wide by 1 1 2 high by 12 long minimum HIGH PROFILE 1 1 2 wide by 1 1 2 high by 12 long minimum 1 1 2 wide by 1 1 2 high by 12 long minimum 1 1 2 wide by 1 1 2 high by 12 long minimum a 1 1 2 wide by 1 1 2 high by 12 long minimum 1 1 2 wide by 1 1 2 high by 12 long minimum NOTE Distance between top of ridge board and bottom of tile must be equal or less than 1 for proper adhesion 1 wide by 1 high by 4 long minimum 1 wide by 1 high by 4 long minimum 1 wide by 1 high by 4 long minimum 1 wide by 1 high by 4 long minimum 1 wide by 1 high by 4 long minimum 1 wide by 1 high by 4 long minimum Hip and Ridge Tile Installation For Drawings 3 5 6 amp 7 Instalaci n de tejas de caballete y cumbrera para Gr ficos 3 5 6 amp 7 Head of tile must be in contact with or within a maximum 1 2 of adjacent tile underlap La cabeza de la teja debe estar en contacto o a no m s de 1 2 del tapeta de baldosas adyacentes For slopes greater than 7 12 Pre bagged or job site mixed mortar may be attach with a nail or screw used for weather blocking areas only When used as a structrual attachment only FBC
10. TORM BOND SISTEMA DE DOBLE CORDON 3 Headlap Apply 3 4 W x 8 L adhesive bead Monta 3 directly onto headlap area of preceeding course on the overlock side of tile Aplique un cord n de 3 4 de ancho x 10 de largo de adhesivo directamente sobre la monta de la hilera precedente en el lado del Ls enganche superior de la teja Apply adhesive bead directly on capsheet Aplique el cord n de adhesivo directamente sobre la membrana S Dispense 1 1 4 W x 10 L adhesive bead under center of tile flange approximately 3 from head end of tile Dispense un cord n de adhesivo de 1 1 4 de ancho x 10 de largo debajo del centro del reborde de la teja aproximadamente a 3 de la cabeza de la teja Drawing 4 Clay Tile Flat Profile Gr fico 4 Teja De Cer mica Perfil Plano TOUCH N SEAL STORM BOND ROOF TILE ADHESIVE PLACEMENT DETAIL DOUBLE BEAD SYSTEM DETALLE DE COLOCACION DEL ADHESIVO PARA TEJAS DE TECHO TOUCH N SEAL STORM BOND SISTEMA DE DOBLE CORDON 3 Headlap Apply 1 2 W x 8 L adhesive bead directly onto head lap area of preceding course on the overlock side of tile Aplique un cord n de adhesivo de 1 2 de ancho x 8 de largo directamente sobre la monta de la hilera precedente en el lado del enganche superior de la teja Monta 3 Dispense 3 4 W x 8 L underlock side adhesive bead approximately 3 from head end of tile Dispense un cord n de adhesivo de 3 4 de
11. as that exceed 240 F 116 C Open Flame Storm Bond propellant is non flammable However Storm Bond adhesive is combustible Section 7 Safety Precautions Whenever Storm Bond Roof Tile Adhesive is being applied personal protective equipment should be used including safety glasses chemical resistant gloves aprons or coveralls footwear chemical protective jackets and or pants Use only in a well ventilated area Avoid contact with eyes and skin Skin contact with Storm Bond may cause irritation or sensitization KEEP OUT OF REACH OF CHILDREN Refer to the enclosed SAFE USE STORAGE AND HANDLING guide for detailed safety precautions Limited Warranty Convenience Products warrants this product to be free from defects The Company shall not be liable for any consequential or other damage or remedy its sole obligation and your exclusive remedy are limited to product replacement Warranty is null and void if unit is operated without attaching a new spray foam applicator gun hose set Some states do not allow limitations on the exclusive or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This Warranty gives you specific legal rights and you may also have other rights which may vary from state to state There are no warranties which extend beyond the description on the face hereof Emergency Telephone Number Call ChemTel Inc within US 1 888 255 3924 Outside US 01
12. ballete de altura suficiente para mantener un plano elevado de las tejas moldura 12 Soporte elevador de cumbrera Acero galvanizado u otro metal de gran resistencia sujetados seg n las instrucciones del fabricante 18 Plataforma de techo 14 L mina asf ltica 15 Teja principal 16 Las aberturas en cumbreras caballetes y contramuros incluyendo chimeneas tragaluces paneles solares y estribos horizontales hacia abajo deber n contar con material que proteja contra las inclemencias del tiempo para mantener el agua sobre la superficie de la teja principal Se permitir n otros m todos aprobados por oficiales locales de la construcci n La envoltura de la clavadera es opcional excepto con el uso de mortero Todos los perfiles de tejas Drawing 1 Concrete Tile Flat Low Profile Gr fico 1 Teja De Hormig n Perfil Plano Bajo TOUCH N SEAL STORM BOND ROOF TILE ADHESIVE PLACEMENT DETAIL DOUBLE BEAD SYSTEM DETALLE DE COLOCACI N DEL ADHESIVO PARA TEJAS DE TECHO TOUCH N SEAL STORM BOND SISTEMA DE DOBLE CORDON 3 Headlap i Monta 3 Apply 1 1 4 W x 8 L adhesive bead directly onto headlap area of preceeding course on the overlock side of tile Aplique un cord n de 1 1 4 de ancho x 8 de largo de adhesivo directamente sobre la zona de monta de la hilera precedente en el lado de enganche superior de la teja Dispense 1 1 4 W x 10 L underlock side adhesive bead approximately 3 from head end of tile
13. cal si hubiera m s requisitos de clavos NOTE Bead dimensions and placement can be modified to accommodate differences in tile configurations as long as the adhesive contact area is not reduced Check at least one tile per square before adhesive cures to confirm contact area To make any adjustments to tiles after tack free time you must have old adhesive beads removed and new adhesive beads applied Walking on the tile before adhesive has cured may cause a slipping hazard NOTA Las dimensiones y colocaci n del cord n pueden modificarse para ajustar a diferencias en la configuraci n de las tejas siempre que no se reduzca la zona de contacto del adhesivo Controle al menos una teja por cuadrado antes de que cure el adhesivo para confirmar la zona de contacto Para hacer cualquier ajuste a las tejas luego de que el adhesivo est seco al tacto debe remover los cordones antiguos de adhesivo y aplicar otros nuevos Caminar sobre la teja antes de que haya curado el adhesivo puede provocar el peligro de resbalarse FIELD TILE INSTALLATION CONCRETE TILES 1 1 4 wide by 10 long CLAY TILES CELTA J 3 wide by 10 long 3 wide by 15 long EAVE TILE INSTALLATION HEAD LAP ADHESIVE BEAD SIZE 1 1 4 by 8 long 34 wide by 10 long 34 wide by 10 long 1 2 wide by 8 long 1 2 wide by 8 long 1 2 wide by 8 long N A TILE TYPE INSTALLATION DRAWING NUMBER CONCRETE TILES CLAY TILES HIP AND RID
14. directamente sobre la monta de la hilera precedente en el lado del enganche superior de la teja Apply adhesive bead Ne A directly on capsheet FDA Myla linn gy My ea CLL LAL AD QL ASA Dispense 3 4 W x 10 L adhesive bead under center of tile flange approximately 3 from head end of tile Dispense un cord n de adhesivo de 3 4 de ancho x 10 de largo debajo del centro del reborde de la teja a aproximadamente 3 de la cabeza de la teja Drawing 7 Clay Tile High Profile Barrel Tile Gr fico 7 Teja De Cer mica Perfil Alto Teja Barril TOUCH N SEAL STORM BOND ROOF TILE ADHESIVE PLACEMENT DETAIL DETALLE DE COLOCACION DEL ADHESIVO PARA TEJAS DE TECHO TOUCH N SEAL STORM BOND Apply 3 4 W x 15 L adhesive bead directly onto the Captile on each side of the pan Aplique un cord n de adhesivo de 3 4 de ancho x 15 de largo directamente sobre la tapa a cada lado de la parte baja de la teja 3 Headlap Dispense 3 4 W adhesive bead under Pan Tiles the length of the tile Dispense un cord n de adhesivo de 3 4 debajo de la teja canal n el largo de la teja Detail A Detalle A See Detail A Ver Detalle A Drawing 12 Grafico 12 STORM BOND ROOF TILE ADHESIVE APPLICATOR ASSEMBLY Montaje del aplicador del adhesivo para tejas de techo Storm Bond Tighten hose to cylinder connection with wrench Manguera de la conexi n del cili
15. gger to test adhesive flow rate on scrap material first Holding aerosol can upside down depress applicator trigger and apply Storm Bond adhesive according to the patterns and bead weights shown in the drawings herein 4 All tiles must be set in adhesive within 4 minutes of adhesive application Section 3 Clean Up If Storm Bond has not cured it is still moist it may be removed by wiping off with a dry cloth or by using Touch n Seal polyurethane foam cleaner Acetone or nail polish remover containing acetone will also work Do not use soap and water as moisture helps to cure Storm Bond No solvent will remove cured dry Storm Bond Cured Storm Bond is not harmful to health and will wear off naturally over time A pumice stone with warm soapy water may be used to gently scrape dried Storm Bond from skin You may also apply petroleum jelly to area wn cover with a plastic glove wait about an hour rub off with an old cloth and then wash area with soap and water Section 4 Storage Store product in a clean dry area in temperatures between 60 120 F 16 49 C REFER TO THE ENCLOSED SAFE USE STORAGE AND HANDLING GUIDE FOR DETAILED RECOMMENDATIONS Section 5 Troubleshooting If Storm Bond quality is suspect at any time during dispensing discontinue application and check the following 1 Verify that the chemical ambient and substrate temperatures are within the specified range 2 Ensure the cylinder valve is full
16. ndro con la llave de apriete Chemical Cylinder Cilindro con producto qu mico Hose Manguera Applicator Aplicador Convenience Products 866 Horan Drive Fenton MO 63026 2416 USA 4004517175 1 800 325 6180 e www touch n seal com MADE IN U S A 52036 010815 TNS
17. y open and the applicator tip is not obstructed 3 Ensure chemical hose is not kinked 4 Ensure chemical cylinders are upright and that aerosol cans are upside down during dispensing For additional assistance contact your Convenience Products Sales Representative or call Convenience Products Customer Service at 800 325 6180 or 636 349 5333 Section 6 Cautions LIMITATIONS AND RECOMMENDATIONS Contact Area For specific square inch contact area for tile to underlayment and tile to tile refer to pages 9 12 Applicator Qualification Storm Bond applicators must pass the required Qualified Applicator Course Contact Area Confirmation Once square inch contact area has been obtained check at least one tile per square to confirm contact area Do not place Storm Bond Roof Tile Adhesive on fresh plastic cement Exposure Limitations Storm Bond Roof Tile Adhesive must not be left exposed to direct sunlight After adhesive cures approximately 1 2 hours point up with mortar or coat any exposed adhesive with an elastomeric coating Setting Tiles All tiles must be set in adhesive within 4 minutes of adhesive application Under normal weather conditions maximum bond strength will be obtained within 24 hours Building Codes Permits Consult local building codes prior to use Surface Temperatures Do not use Storm Bond Roof Tile Adhesive in direct contact with chimneys heat vents steam pipes or other surface are