1. Haga correr agua por el grifo antes de conectar el mismo a la red el ctrica para llenar de agua la c mara de calentamiento y para que no se queme la resistencia fig 10 Verifique si hay algun escape de agua y cierre el registro No deber ser conectado en la salida del grifo dispositivos que no est n indicados en este manual Atenci n Repita estas operaciones siempre que el grifo esretirado por algun motivo Before connecting the unit to the wires let the water flow through the product in order to have the chamber filled and avoid burning the heating element Pic10 While the water flows through the unit check out for any leakage points and then close the water valve This unit should not be connected to any other than the ones mentioned in this manual Attention Make sure that this operation is repeated every time the tap unit is removed from the wall INSTALACION EL CTRICA ELECTRIC INSTALLATION En el caso de construcci n nueva providencie la caja de derivaci n a un rayo pr ximo de 13 cm de distancia arriba de la salida de fig 11 Antes de conectar los cables el ctricos del grifo a los alambres de la red el ctrica mu valos de modo que permanezca una holgura hasta la caja de derivaci n fig 12 para facilitar futuramente una eventual substituci n de la resistencia No conectar los cables sin SALIDA DE AGUA WATER OUTLET dejar holgura hasta la caja de derivaci n fig 13 R13 c
2. producto a un sistema de puesta a tierra eficaz No use el cable neutro como puesta a tierra El sistema de puesta a tierra le garantiza su seguridad durante el uso de aparatos electrodom sti cos Para llegar a una m xima eficiencia el sistema de puesta a tierra debe ser instalado por un profesional capacitado Una buena puesta a tierra se obtiene con la colocaci n de Jabalinas en el suelo obteni ndose una impedancia m xima de 10 ohms fig 15 eln order to avoid the risk of electric shocks make sure to connect the grounding wire of the tap unitto a ground system Do not use the neutral wire as a ground one arhg ground system guarantees your safety while the utilization of home appliances are user For better efficiency the ground system mustbeperformed by professional sA good ground system is obtained with the installation of cooper ground rods in the floor getting maximum impedance of 10 ohms CAJA DE INSPECCION INSPECTION BOX CABLE TIERRA GROUNDING WIRE CUADRO DE DISTRIBUCION SWITCHBOARD JABALINA GROUNDING SUPPORT PISO FLOOR 8 UTILIZACION USAGE Conecte el disyuntor o llave fusible del cualdro de distibuci n de energia el ctrica en el cual est instalado su grifo Abriendo el registro el grifo con cta autom ticamente Cuando prefi ra menor calentamiento cierre el registro y coloque la tecla de selecci n de temperatura en la posici n que m s le agrade fig 16 SELECTOR C
3. aliente Hot eTurn on the cricuit breaker or fuse of the main switchboard where the tap unitis connected to Open the water valve The tap turns automatically on If you prefer more or less heating close the water valve and switch the temperature key to the position that pleases you most Pict 16 Desliga Tibia Warm Desconecta OFF eLa temperatura del agua tambien puede ser regulada atrav s del registro Para dias m s calientes use la tecla selectora de temperatura en la posici n de menor calentamiento potencia econ mica Para su seguridad y mayor vida til de los componentes del grifo accione la tecla selectora de temperatura solamente con el registro cerrado eThe water temperature can also be controlled by the water valve For warm days use the unit in the economic position economic power For your own safety and to provide a longer life to the components of the unit only use the switch key if the water valve register closed 09 FUNCIONAMIENTO DEL REGISTRO WATER VALVE USE Para abrir el grifo gire la manopla hacia arriba fig 17 Para cerrar el grifo gire la manopla hacia abajo fig 18 Atenci n Si percibe algunas gotas de agua escurriendo del grifo despu s de cerrarlo no haga fuerza en la manopla estas gotas pertenecen al agua acumulada en el producto y se agotan rapidamente eTurn the gauntlet up to open the tap Pic 17 Turn the gauntlet down to close the tap Pic 18 Attention If you n
4. m eFor new constructions make sure to provide a derivate box 13 cm above the water outlet Before connecting the electric cables of the tap to the wires of the electric network measure them in order to have same space until the derivation box to make easier any future substitution ofthe heating element Pic 12 Caja de Derivacion Cajade Derivacion Derivation Box Derivation Box Cables Wires Cables Wites Correcto Right Incorrecto wrong Certif quese que la llave general o disyuntor del circuito que alimentar su grifo est desconectado Conecte los cables de conexi n del grifo a los cables de la red el ctrica usando un conector adecuado a la tensi n y corriente el ctrica del grifo fig 14 Este conector no acompa a el producto Atenci n No use ning n tipo de toma o triple para la instalaci n de este aparato Be sure that the main switch and the circuit breakers of the tap are turned off Connect the unit to the wires and make sure the connectors used match the right voltage and power rating of the electrical circuitofthe tap Pic 14 eThis connector does not come with the product Espejo Mirror Plate 7 Grfo Tap Attention Do not use plugs or socket for the product installation 7 Puesta a tierra Grounding Wire Importante para su seguridad For your own safety Para evitar riesgos de choques el tricos conecte el cable de tierra del
5. otice some water dropping from the tap after the register is closed do not force the gauntlet to close because these could generate an excess of water in the unit which should dry soon MANOPLA 17 MANOPLA 18 RO Abre Open Cierra Closed En el caso de da os a los conductores del cord n de alimentaci n del aparato no los substituya contacte personal especializado eIn case of damages in the wires of the product are damaged disconnect the unit from the electrical system immediately never change the wires Take the productto atechnician 10 ATENCION ATTENTION Ni os personas de mucha edad enfermos personas fisica o mentalmente incapacitadas deben ser supervisionados cuando de la utilizaci n del aparato No altere el regulaje de los contactos del producto pues esto le garantiza el buen funcionamien to del aparato Children the elderly sick disabled or mentally ill people must be supervised if they need to use the equipment Do not change the settings of the electrical contacts as they guarantee the perfect operation of the product 11 LIMPIEZA Y MANTENIMIENTO CLEANING AND MAITENANCE Antes de iniciar la limpieza del producto desconecte el disyuntor o llave fusible en el cuadro de distribuci n de energ a el ctrica del circuito en el cual el grifo ser instalado Use solamente un pa o h medo para limpieza el uso de productos abrahasivos puede da ar s
6. res est n de acuerdo con las especificaciones contenidas en este manual Contact a qualified technician to check the your electrical installation No sale agua por el fo rifo Ro water is flowing Through the tap Cableado inadecuado The wires do not have the properly size as specified in the instruction manual El grifo calienta o o mismo con la echa selectora en Tensi n el ctrica baja Contacte un profesional habilitado para verificar si la Low Volltage The voltage tensi n electrica est abajo de los valores nominales de la posici n caliente of your system may not A The tap is not iant or under suministro 127 V ou 220 V En caso positivo eating properi the values specified comunique el proveedor de energia el ctrica de su regi n pan sect hey Contact a qualified professional to verify your electric system If the nominal voltage at your system is under the values specified by your electrical supplier 110V 127V or 220V Av Presidente Wilson 1230 CEP 03107 901 C D 370xxx Set 04 M oca S o Paulo SP www lorenzetti com br
7. u aparato Before cleaning disconnect the circuit breaker in the main switchboard Use a wet cloth for external cleaning Never use chemical products In case of doubts call a specialized technical 12 EVENTUAIS PROBLEMAS E RESPECTIVAS SOLU ES FREQUENT QUESTIONS AND ANSWERS Observe el cuadro abajo antes de llamar personal capacitado Please read the table below before requesting technical support Problema Problem Causa Prov velProbable reason Soluci n Solution Disyuntor o llave fusible desconectados Circuit breaker or fuse is tumed OFF Accione el disyuntor o llave fusible El grif ta Sri el registro Tum the oricui or fuse ON al abrir el registro It does not turn on La tecla selectora de temperatura se Coloque la tecla selectora de temperatura encuentra en la posici n fria en la posici n Tibia o Caliente The selection temperature key is in Put the selection temperature key in the OFF position warm or hot El registro principal est cerrado o hay aire en su ca eria The main register is closed or there is air inside th pipes Abra el retistro principal y o grifos que ertenezcan al mismo circuito hidr ulico asta retirar todo el aire Open the majn register andlor the taps and let the water flow to remove the air The tap head must be disconnected from the electrical system circuit breakers off Contacte un profesional habilitado para verificar s los conducto

Download Pdf Manuals

image

Related Search

Related Contents

Manual del Usuario  Télécharger le programme - Congrès Aquitain de Médecine d`Urgence  Invacare® Pegasus  Anzeigen - Service  0J8903 RevC.indd  Broadlands Water Booster Pump Station Phase III  PB960 PN960 PS960 PT960 PX960 - Domstore Elettrodomestici da  Vlink Quick Start Guide  Philips HD7692 Coffeemaker  