1. 0051 CPD 0197 J424 0051 CPD 0196 J408 2 1408 4 J408 8 EN12094 1 Electrical automatic control and delay device Enviroment class A 1 2 flooding zones CO2 inert gas Halocarbon gas Provided options Delay of extinguishing signal Monitoring of status of components Control of flooding time Delay of extinguishing signal Response delay activated condition maximum 3 s Response delay triggering of outputs maximum 1 s Nota Si este M dulo de Extinci n NO se instala en Centrales certificadas EN54 caducala conformidad con la norma EN12094 1 Este M dulo de Extinci n se puede instalar en aquellas Centrales indicadas en el envase En esta hoja se describe el montaje del M dulo de Extinci n Para mayorinformaci n sobre las conexiones sobre la programaci n y sobre el uso del M dulo de Extinci n leere MANUAL DE INSTALACI N dela Central INSTALACI N EN CENTRALES CON TAPA DEPL STICO Para instalar el M dulo de Extinci n en centrales con tapa de pl stico proceder como se describe a continuaci n Fig 1 1 Quite los tornillos y abrir la central 2 Pongala tarjeta con la cara de los componentes hacia usted Inserte el M dulo de Extinci n debajo delas grapas a en la parte de arriba vea la Figura 1A entonces col quelo suavemente en su lugar Aseg rese que est bien encajado en los pins de pl stico e vea la Figura 1A y que se sostiene firmemente en su posici n porlas grapas c seg
2. MODULO DI ESTINZIONE per Centrali Antincendio Convenzionali vedere i modelli sulla confezione EXTINGUISHMENT MODULE for Conventional Fire Panels compatible models listed on the carton box MODULO DE EXTINCION para centrales de incendio convencionales Ver los modelos en el envase ISTISNE3J400 EXT 2 1 090709 P70 aba a Fig 1 Installazione del Modulo di Estinzione su Centrali con coperchio plastico Installing the Extinguishment Module on plastic cover panels Instalaci n del M dulo de extinci n en Centrales con tapa de pl stico d e d e f f AN 90 Q TS 3 Po gi A d e d e f Fig 2 Installazione del Modulo di Estinzione su Centrali con coperchio metallico Installing the Extinguishment Module on metal cover panels Instalaci n del M dulo de extinci n en Centrales con tapa met lica ITALIANO 09 0051 CPD 0197 J424 0051 CPD 0196 J408 2 J408 4 3408 8 EN12094 1 Dispositivo elettrico di controllo e ritardo automatico Classe ambientale A 1 2 zone di scarica CO2 gas inerte idrocarburi alogenati Opzioni previste Ritardo del segnale di estinzione Sorveglianza dello stato dei componenti Dispositivo di prolungamento emergenza Controllo del tempo di allagamento Condizione attivata nel ritardo nella risposta massimo 3 s Attivazione del ritardo della risposta delle uscite massimo 1 s N B Se questo Modulo di Estinzione NON viene installa
3. n 2 n Conector para el M dulo de Extinci n consecutivo s Terminal para conectar a la Placa Principal k Conector para el M dulo de Extinci n n 1 5 Applicare l etichetta fornita con il Modulo di Estinzione sul lato della Centrale vicino all etichetta dati di targa gi presente INSTALLAZIONE SU CENTRALI CON COPERCHIO METALLICO Per installare il Modulo di Estinzione su centrali con coperchio metallico procedere come descritto di seguito Fig 2 1 Aprire la Centrale 2 Inserire i distanziatori e forniti in dotazione sui perni d 3 Fissare il Modulo di Estinzione tramite i dadi f forniti in dotazione 4 Impostare l indirizzo del Modulo di Estinzione tramite il ponticello contrassegnato con il numero 1 sulla scheda elettronica O ponticello 1 inserito Modulo di Estinzione n 1 ponticello 1 rimosso Modulo di Estinzione n 2 Il ponticello contrassegnato con il numero 2 sulla scheda elettronica DEVE RIMANERE INSERITO 5 Collegare il Modulo di Estinzione tramite la piattina fornita in dotazione O Se viene installato UN Modulo di Estinzione collegare il connettore s del Modulo di Estinzione al connettore k della Scheda di Madre Fig 3A e Se vengono installati DUE Moduli di Estinzione collegare il connettore n del Modulo di Estinzione n 2 al connettore n del Modulo di Estinzione n 1 quindi collegare il connettore s del Modulo di Estinzione n 1 al connettore k della
4. n la Figura 1B 3 Aseg rese que los Puentes marcados como 1 y 2 en la placa est n puestos M dulo de Extinci n n 1 4 Usando el cable plano o conecte el M dulo de Extinci n a la Placa Principal mediante sus conectores s y krespectivamente Oo D gt gt Fig 3 ECollegamento di UN Modulo di Estinzione A e DUE Moduli di Estinzione B g Scheda di Controllo della Scheda Madre h Scheda Madre o e p piattina per il collegamento del Modulo di Estinzione i Modulo di Estinzione n 1 m Modulo di Estinzione n 2 n connettore peril collegamento del Modulo di Estinzione sucessivo s connettore per il collegamento alla Scheda Madre k connettore perilcollegamento del Modulo di Estinzione n 1 Fig 3 Connecting ONE Extinguishment Module A or TWO Extinguishment Modules B g Main Control Board h Main Board o and p Flat cable for the connection of the Extinguishment Modules i Extinguishment Module nr 1 m Extinguishment Module nr 2 n Jack for the connection to the consecutive Extinguishment Module s Jack for the connection to the Main Board k Jack for the connection of Extinguishment Module nr 1 Fig 3 Conexi n de UN M dulo de Extinci n A o DOS M dulos de Extinci n B a la Central g Placa de Control Principal h Placa Principal o y p cable plano para conectarlos M dulos de Extinci n i M dulo de Extinci n n 1 m M dulo de Extinci n
5. specific information see www bentelsecurity com en environment htm Se tiene que observar la polaridad de los conectores del cable plano 5 Aplicar la etiqueta suministrada con el M dulo de Extinci n en el lado de la Central cerca de la etiqueta datos de la placa ya presente INSTALACI N EN CENTRALES CON TAPA MET LICO Para instalar el M dulo de Extinci n en centrales con tapa met lica proceder como se describe a continuaci n Fig 2 1 Quite los tornillos y abrir la central 2 Encaje los separadores e en los pins de pl stico d 3 Usando las tuercas f asegure el M dulo de Extinci n en su posici n 4 Usando al Puente marcado como 1 en la placa ponga la direcci n del M dulo de Extinci n e Puente PUESTO M dulo de Extinci n n 1 e Puente QUITADO M dulo de Extinci n n 2 El Puente marcado como 2 en la placa DEBE INSERTARSE 5 Uselos cables planos para conectarlos M dulos de Extinci n como sigue e Si usted est instalando UN M dulo de Extinci n con ctelo a la Placa Principal mediante los conectores s y k respectivamente seg n la Fig 3A e si usted est instalando DOS M dulos de Extinci n conecte el M dulo de Extinci n n 1 al M dulo de Extinci n n 2 mediante los conectores n luego conecte el M dulo de Extinci n n 1 a la Placa Principal mediante los conectores s y krespectivamente seg n la Fig 3B Se tiene que observar la polari
6. Delay of extinguishing signal Monitoring of status of components Control of flooding time Delay of extinguishing signal Response delay activated condition maximum 3 s Response delay triggering of outputs maximum 1 s NOTE Compliance with the EN12094 1 standard fails if the Extinguishment Module is installed in Control Panels that do not meet the EN54 standard This ExtinguishmentModule can be installed in the Control Panels listed on the carton box This sheet describes how to mount the Extinguishment Module Please read the Control Panel INSTALLATION MANUAL forfurther information aboutthe Extinguishment Module connections programming and use INSTALLATION ON PLASTIC COVER PANELS Toinstall the Extinguishment Module in the plastic cover panels proceed as described below Fig 1 1 Open the Fire Panel 2 Hold the unit with the component side facing you Insert the Extinguishament Module under the clips a onthe top part ofthe housing see Fig 1A then snap it gently into place Ensure that it is resting properly on the plastic support pins e and thatit is held firmly in position by the clips c as per Fig 1B 3 Ensure thatthe Jumpers marked 1 and 2 on the PCB are inserted Extinguishment Module no 1 4 Using the Flat cable o connect the Extinguishment Module to the Main Board via the jacks s and k respectively The flat cable connectors can be inserted in the correct way only 09
7. Scheda Madre Fig 3B connettori della piattina sono ad innesto obbligato quindi possono essere inseriti solo nel verso giusto 6 Applicare l etichetta fornita con il Modulo di Estinzione sul lato della Centrale vicino all etichetta dati di targa gi presente Informazioni sul riciclaggio BENTEL SECURITY consiglia ai clienti di smaltire i dispositivi usati centrali rilevatori sirene accessori elettronici ecc nel rispetto del l ambiente Metodi potenziali comprendono il riutilizzo di parti o di pro iclaggio di prodotti componenti e o materiali www bentelsecurity comlitlambiente htm Direttiva Rifiuti di apparecchiature elettriche ed elettroniche RAEE WEEE E Nell Unione Europea questa etichetta indica che questo pro E dotto NON deve essere smaltito insieme a Deve esse re depositato in un impianto adeguato che sia in grado di eseguire ope razioni di recupero e riciclaggio Per maggiori informazioni visitare www bentelsecurity com it ambiente htm 5 Attach the label supplied with the Extinguishment Module on the Control Panel side where the data label is located INSTALLATION ON METAL COVER PANELS To install the Extinguishament Module in the metal cover panels proceed as described below Fig 2 1 Open the Fire Panel 2 Fit the spacers e onto the plastic pins d 3 Using the nuts f secure the Extinguishment Module in position 4 Using the Jumper marked 1 on the PCB set u
8. dad de los conectores del cable plano 6 Aplicar la etiqueta suministrada con el M dulo de Extinci n en el lado de la Central cerca de la etiqueta con los datos de la placa ya presente Informaciones sobre el reciclado BENTEL SECURITY aconseja la los clientes reciclar los dispositivos usados centrales detectores sirenas acessorios electr nicos etc respetando el medio ambiente M todos potenciales incluyen la reutilizaci n de piezas o de pr oductos enteros y el reciclado de productos componentes y o materiales Para obtener m s informaciones visite www bentelsecurity com en environment htm Directiva sobre Res duos de Equipamientos El ctricos y REEE WEEE Electr nicos Ne la Uni n Europea esta etiqueta indica que este producto en m el debe ser tratado conjuntamente con los residuos dom sticos Debe ser depositado en una instalaci n adecuada que sea capaz de realizar operaciones de valoraci n y del reciclado Para obtener m s informaciones visite www bentelsecurity com en environment htm
9. p the Extinguishment Module address e jumper IN Extinguishment Module nr 1 e jumper OUT ExtinguishamentModule nr 2 The Jumper marked 2 on the PCB MUST BE INSERTED 5 Using the Flat cables connect the Extinguishment Modules as follows O if you are installing ONE Extinguishment Module connect it to the Main Board via the jacks s and k respectively as per Fig 3A O if you are installing TWO Extinguishment Modules connectExtinguishment Module nr 1 to Extinguishment Module nr 2 via the jacks nthen connect Extinguishment Module nr 1 tothe Main Board via the jacks s and k respectively as per Fig 3B The flat cable connectors can be inserted in the correct way only 6 Attach the label supplied with the Extinguishment Module on the Control Panel side where the data label is located Recycling information BENTEL SECURITY recommends that customers dispose oftheir used equipments panels detectors sirens and other devices in an environmentally sound manner Potential methods include reuse of parts orwhole products and recycling of products components and or materials For specific information see www bentelsecurity com en environment htm Waste Electrical and Electronic Equipment WEEE Directive pd In the European Union this label indicates that this product a should NOT be disposed of with household waste It should be deposited atan appropriate facility to enable recovery and recycling For
10. to in Centrali certificate EN54 decade la conformit alla norma EN12094 1 Questo Modulo di Estinzione pu essere installato nelle Centrali indicate sulla confezione In questo foglio si descrive il montaggio del Modulo di Estinzione Per maggiori informazioni sui collegamenti sulla programmazione e sull uso del Modulo di Estinzione leggere il MANUALE DIINSTALLAZIONE della Centrale INSTALLAZIONE SU CENTRALI CON COPERCHIO PLASTICO Per installare il Modulo di Estinzione su centrali con coperchio plastico procedere come descritto di seguito Fig 1 1 Aprire la Centrale 2 Inserire il Modulo di Estinzione tra i perni b e le squadrette a come mostrato nella Fig 1A quindi premere il Modulo di Estinzione verso il coperchio fino a quando non viene bloccato in posizione dai ganci c come mostrato in Fig 1B 3 Assicurarsi che i ponticelli contrassegnati con i numeri 1 e 2 sulla scheda elettronica siano inseriti Modulo di Estinzione n 1 4 Collegare ilconnettore s del Modulo di Estinzione al connettore k della Scheda Madre tramite la piattina o fornita in dotazione Fig 3A Iconnettori della piattina sono ad innesto obbligato quindi possono essere inseriti solo nel verso giusto ENGLISH 09 0051 CPD 0197 J424 0051 CPD 0196 J408 2 J408 4 J408 8 EN12094 1 Electrical automatic control and delay device Enviroment class A 1 2 flooding zones CO2 inert gas Halocarbon gas Provided options