1. Cable o terminals o Not used do Signal Common For a wire of 1 5 mm section the total length of the network must not exceed 400 m 3 Fix the connector block back onto the mountting base 4 Lock the detector on its base see Mounting CAUTION connect only detectors of the same model within the network 42 5 Detector tests Although the alarm sound volume is reduced during a manual test of a smoke detector it is advisable to inform neighbours prior to running the test and to use all suitable hearing protection devices Manual test Press for approximately 10 sec the test key until the built in alarm sounds The alarm rings until the test button is released Red signal LED White indicates the state indicator of the detector LED Built in audible alarm the alarms rings ibi the LED flashes lit for 1 sec 75 dB A the test si Ji quickly from a 3 m distance 9 then stops for 1 sec i the alarms rings mterconnected MeLEDfshes y for sec 75 dB A detectors quickly from a 3 m distance then stops for 2 sec Connected to a Hager system it goes immediately a button is pressed for 10 sec e triggering of the control panel siren and the alarm sirens in fire alarm modulation for 5 minutes e triggering of the telephone dialler e triggering wired sirens Stop the sirens and check that the control panel has memorised the alarm
2. Inibizione volontaria del rivelatore possibile disattivare il rivelatore per una durata di 15 minuti Per non disturbare in orari notturni la segnalazione sonora di anomalie d alimentazione o di testa di rilevazione intasata inibita durante la notte L anomalia verr quindi segnalata al ritorno della luce per pi di 10 minuti o dopo 12 ore dall inizio dell anomalia e prima di intraprendere attivit eventualmente generatrici di fumo pulizia d una stanza polverosa disintasamento d un caminetto e quindi attivazioni intempestive per tacitare l allarme in caso di rivelazione di fumo non pericolosa A questo scopo premete il pulsante di test fino all emissione del primo bip o fino a quando il rivelatore disattiver la propria suoneria integrata La spia di segnalazione lampeggia ogni 2 secondi per segnalare l inibizione del rivelatore Rivelatore in inibizione Spia rossa di segnalazione 1 lampeggio ogni 2 secondi Spia bianca Suoneria integrata Altri rivelatori collegati in rete filare 1 lampeggio ogni 10 secondi ATTENZIONE durante i 15 minuti di inibizione il rivelatore non potr n rilevare fumo n generare allarmi AI termine dei 15 minuti il rivelatore ritorna automaticamente in funzionamento normale e la spia di segnalazione emetter 1 lampeggio ogni 10 secondi DICHIARAZIONE DI CONFORMIT D C Fabbricante Hager Securit
3. Fixation standard 1 Placer le socle l emplacement pr vu puis marquer au crayon la position des 2 trous de fixation rep r s 69 ou 63 2 Percer l aide d un foret de 5 mm 3 Fixer le socle l aide de chevilles et de vis appropri es Fixation sur bo te d encastrement 1 Pour des bo tes d encastrement de 60 mm utiliser les trous de fixations rep r s 0 2 Pour des bo tes d encastrement de 85 mm utiliser les trous de fixations rep r s 3 Fixer le socle l aide de vis appropri es ATTENTION pour permettre entr e de ots do enon diametro cables en saillie d tacher les 2entretoises Rep re d alignement de fixation et les intercaler entre le plafond de la touche test et le socle en coiffant les 2 trous de fixation choisis Entretoises de fixation a Trous de fixation diam tre 85 Verrouillage optionnel du d tecteur sur le socle de fixation Le verrouillage optionnel est con u pour d courager la d pose non autoris e du d tecteur A l aide d une pince coupante couper le t ton de verrouillage ATTENTION l ouverture ne sera d sormais possible qu l aide d un tournevis lame plate Aligner les 2 fleches de rep rage pr sentes sur le socle et le d tecteur puis verrouiller le en tournant dans le sens des aiguilles d une montre ATTENTION le d tecteur ne peut pas tre verrouill sur son socle si le bloc lithium n est pas dans son lo
4. wo sus Autres d tecteurs Clignote 1 s de sonnerie interconnect s rapi dh ent allum 75 dB A 3 m filairement pi suivi de 2 s de pause 2 R actions suite un appui sup rieur 10 s sur la touche test et jusqu au rel ch de cette touche Ne jamais se servir d une flamme nue pour tester le d tecteur de fum e Ces essais sont r aliser au moins une fois par mois et notamment apr s une longue absence Signalisation de l anomalie d alimentation de l anomalie toutes les 5 s Voyant rouge de signalisation de Voyant Sonnerie l tat du d tecteur D tecteur l origine 1 clignotement 2 bips rapides toutes les 60 s Autres d tecteurs interconnect s filairement Signalisation de l anomalie de t te de d tection encrass e Si la signalisation sonore du d faut d alimentation ou de t te de d tection encrass e appara t un moment inopportun il est possible de la reporter de 8h sur une dur e maximale de 7 jours en appuyant sur la touche test jusqu au 1 bip Vous disposez ainsi de ce laps de temps pour faire intervenir votre installateur de l anomalie toutes les 8 s Voyant rouge de signalisation de voyant Sonnerie l tat du d tecteur D tecteur l origine 8 clignotements 8 bips rapides toutes les 58 s Autres d tecteurs interconnect s filairement Inhibition volontaire de votre d tecteur Afin d
5. 051 671 44 50 Un gruppo di tecnici competenti vi indicher la procedura da seguire pi adatta al vostro caso 10 Scheda uso foglietto staccabile da consegnare all utilizzatore Preparazione all incendio Prevedete un itinerario di evacuazione e Predisponete un piano di eva cuazione per tutte le stanze e La minore concentrazione di fumo vicino al suolo uscite tenendovi il pi bassi possibile e Quando l allarme suona svegliate tutti gli occupanti dei locali e Prevedente un punto d incontro all esterno dei locali e Evitate di entrare inutilmente nei locali in cui si verificato l incendio e Chiamate i pompieri In caso di lavori E assolutamente vietato dipin gere il rivelatore Se si rende necessario effettuare lavori sulle pareti dopo l installazione del rivelatore necessario coprire completamente il rivelatore con l apposita copertura plastificata fornita Ricordate di rimuovere la protezione plastificata al termine dei lavori Riassunto delle reazioni e delle segnalazioni del rivelatore Funzionamento nomale Spia rossa Spia di segnalazione bianca Suoneria integrata 1 lampeggio Tutti i rivelatori ogni 10 secondi Rilevazione di fumo 1 Spia rossa Spia A disegnalazione bianca Suoneria integrata Rivelatore p I igi lampeggia suoneria continua all origine della accesa rilevazione di fumo rapidamente a85 dB A a3 m Alt
6. See section on Indication CAUTION e Never use a naked flame to test the smoke detector e A test should be carried out at least once a month particularly after you have been away for a long period of time Detection test Using the smoke generator Ref TESTFUM spray smoke through the slots about 10 cm away from the detection head for 1 to 2 seconds After 10 seconds maximum the detector issues a series of increasingly fast beeps until the detector is triggered 12 to 22 seconds after spraying If the detector does not beep there is not enough smoke around the detection head Spray some more smoke through the slots For this type of test the detector s responses are described in the Detector operation paragraph 6 Manual disabling of the detector It is possible to disable the detector for a 15 min period e prior to activities likely to produce smoke Sweeping of a dusty room of a chimney and cause unwanted alarm activation e to stop alarm in the event of detection of non dangerous smoke In order to disable the detector press the test key until the 1st beep sounds or until the detector stops its built in audible alarm The indicator signalling the state of the detector flashes every 2 sec Red signal LED White indicates the state indicator Built in audible alarm of the detector LED the unit flashes once Sensor shut down every 2 sec Other wired inter connecte
7. Spia rossa Spia di segnalazione bianca Suoneria integrata Rivelatore 1 lampeggio n n in inibizione ogni 2 secondi Altri rivelatori 4 1 lampeggio collegati ogni 10 secondi 7 7 in rete filare g Al termine dei 15 minuti il rivelatore ritorna automaticamente in funzionamento normale e la spia di segnalazione emetter 1 lampeggio ogni 10 secondi ATTENZIONE per uscire pi rapidamente dall inibizione tenete premuto per circa 10 secondi il pulsante di test fino all attivazione della suoneria integrata v par Test del rivelatore MM 7 Segnalazione 7 1 degli allarmi Alla ricezione del comando di Spento la centrale segnaler l avvenuto allarme con il messaggio in sintesi vocale bip il data alle ore ora allarme incendio rivelatore X 7 2 delle anomalie ATTENZIONE per non disturbare in orari notturni la segnalazione sonora di anomalie d alimentazione o di testa di rilevazione intasata inibita durante la notte L anomalia verr quindi segnalata al ritorno della luce per pi di 10 minuti o dopo 12 ore dall inizio dell anomalia Anomalia di alimentazione sul rivelatore Spia rossa Spia nae ATTENZIONE quando viene di segnalazione bianca Suoneria integrata segnalata una anomalia di Rivelatore 1 lampeggio 2 bip rapidi dle tio oo in anomalia ogni 5 secondi ogni 60 secondi ha una autonomia residua di circa 30 giorni Altri rivelato
8. nico 2 Si usted completa un sistema utilice la solicitud de extensi n de garant a incluida en la gu a ED 2 Alimentaci n Conectar la bater a cuidando de respetar la polaridad El testigo rojo indicador parpadea durante 15 seg y luego una vez cada 10 seg para indicar el funcionamiento correcto del detector ES La programaci n permite establecer el reconocimiento del detector de humo por la central Para efectuar la programaci n la central debe estar en modo instalaci n Para ello pulsar gt DOO D ATENCI N durante la programaci n no colocar el producto cerca de la central Al contrario aconsejamos colocarlo c digo maestr a cierta distancia al menos a 2 metros de la central y despu s pulsar Re DO D PP U c digo instalador Realizar la secuencia de programaci n siguiente H C Bip detector incendio n X D 10 seg m x H Pulsar y despu s en Mantener la pulsaci n sobre la tecla de programaci n 0 el teclado de la central durante 10 seg hasta la respuesta de la central Es posible registrar un mensaje personalizado permitiendo identificar vocalmente el detector de incendio ver Gu a de instalaci n de la central Mensaje de identificaci n vocal 4 Instalaci n del detector ES ATTENTION respetar la distancia de al menos 2 metros entre cada producto exceptuando entre dos det
9. utilizzando una bomboletta test per 1 2 secondi Entro 10 secondi massimo il rivelatore emetter una serie di toni acustici bip via via pi ravvicinati fino all attivazione che avverr in un tempo da 12 a 22 secondi Se la serie di toni acustici non si avvia significa che la concentrazione di fumo nella testa di rilevazione non sufficiente nebulizzate nuovamente utilizzando la bombola di test Le reazioni del rivelatore a questo tipo di test sono descritte nel paragrafo Principio di funzionamento e Per testare il rivelatore di fumo non fate mai uso di una fiamma libera e E consigliabile effettuare un test di funzionamento una volta al mese e comunque dopo ogni assenza prolungata 6 Inibizione volontaria del rivelatore possibile disattivare il rivelatore per una durata di 15 minuti ATTENZIONE durante i e prima di intraprendere attivit eventualmente generatrici di 15 minuti di inibizione il fumo pulizia d una stanza polverosa disintasamento d un rivelatore non potr n caminetto e quindi attivazioni intempestive rilevare fumo n generare e per tacitare l allarme in caso di rivelazione di fumo non allarmi pericolosa A questo scopo premete il pulsante di test fino all emissione del primo bip o fino a quando il rivelatore disattiver la propria suoneria integrata La spia di segnalazione lampeggia ogni 2 secondi per segnalare l inibizione del rivelatore
10. 1 m away from heating cooling or ventilation grilles likely to spread smoke e less than 6 m away from a fireplace or wood burning stove where combustion fumes could cause untimely alarms e in premises where cooking fumes and steam could result in untimely triggering e in premises where there is a risk of condensation or humidity bathrooms laundries etc e at the top of pointed A shaped ceilings as an air pocket at this point could prevent smoke from reaching the detector Fig 2 Mounting examples Fig 1 d gt 50cm Recommended location 60 cm gt d gt 50 cm Acceptable location Fig 2 d gt 50 cm 4 2 Testing the radio link at the chosen location CAUTION the control panel must be in installation mode in order to effect this test see familiarisation 1 Hold down the detector programming key 0 or the test key until the integral alarm sounds e correct the control panel confirms the radio link with a voice message beep fire detector n X e incorrect no voice message at all go back to the smoke detector at the control panel 2 Put the control panel back in user mode and press SEE A DAPR engineer installer code 4 3 Fixing Standard fixing method 1 Install the base in the desired location then mark the position of the 2 fixing holes using a pencil Ref mark or 63 2 Drill holes using a 5 mm drill bit 3 Fix the base using appropriat
11. 40 detectores Longitud de la red 400 m m x Di metro del cable 1 5 mm m x Enlace radio TwinBand 800 400 MHz Temperatura de funcionamiento 10 C a 55 C Indice de protecci n IP 32 Dimensiones D x H 125 x 48 mm Peso 2109 10 Ficha de utilizaci n parte recortable a remitir al usuario Precauci n para incendio e Prever un itinerario de evacuaci n e Preparar un plan de evacuaci n para todas las estancias e En el suelo es donde hay menos humo salga arrastr ndose e Con el sonido de la alarma alertar a todo el mundo e Prevea un punto de encuentro en el exterior de la vivienda e Evite cualquier entrada in til en la vivienda con fuego e Llame a los bomberos En caso de obras en la casa No pintar el detector en ning n caso Si se deben efectuar obras en la casa despu s de la instalaci n cubrir completamente el detector con la protecci n de pl stico incluida ATENCI N no olvide retirar la protecci n al final de las obras Resumen de las reacciones y de las se alizaciones de su detector Funcionamiento normal Testigo rojo i indicador del eo Sirena estado del detector Todos sus el testigo parpadea a 7 detectores cada 10 seg Detecci n de humo 1 Testigo rojo A indicador del Teo Sirena estado del detector disparo de una alarma Detector que parpadeo rapido activado integrada continua detecta el hum
12. allarmi 7 2 Delle anomalie 8 Manutenzione 30 8 1 Manutenzione della testa di rilevazione 30 8 2 Cambio della pila 31 8 3 In caso di lavori 31 9 Caratteristiche 32 10 Scheda uso 33 1 Presentazione 1 1 Principio di funzionamento Il rivelatore ottico di fumo adatto in particolare per rilevare incendi a combustione lenta che possono covare per molte ore prima di svilupparsi E destinato a proteggere parti private di immobili o residenze abitative Pu essere e abbinato ad un sistema d allarme logisty expert di Hager sicurezza con centrale TwinBand e usato da solo Modalit stand alone e collegato ad una rete filare composta da un massimo di 40 rivelatori Se usato da solo in caso di rilevazione di fumo reagisce come indicato nella tabella seguente Spia rossa Spia Ba di segnalazione bianca Suoneria integrata Rivelatore all origine i A lampeggia suoneria continua della rilevazione accesa di fumo rapidamente a85dB A a3m Altri rivelatori collegati accesa rts terres in rete filare Abbinato ad un sistema d allarme logisty expert di Hager sicurezza provoca inoltre e l attivazione della sirena incorporata alla centrale e le sirene d allarme in modulazione incendio per 5 minuti e l attivazione del combinatore telefonico ATTENZIONE si raccomanda di sostituire il rivelatore di fumo
13. con obbligo di manutenzione regolare e normale ogni 10 anni La data di sostituzione consigliata e indicata sul retro del prodotto 1 2 Descrizione 2 Alimentazione Spia rossa di d Collegate la pila al litio segnalazione dello A H i Stato del rivelatore rispettando il senso di collegamento Pulsante test La spia rossa di segnalazione lampeggia per 15 secondi e poi di nuovo 1 volta ogni 10 secondi per indicare che il rivelatore funziona correttamente Spia bianca illuminazione di soccorso in caso di rivelazione di fumo Data di Etichetta edit di garanzia sostituzione del prodotto i Connettore Pulsante di pila al litio programmazione 0 Etichetta di garanzia 1 Staccate la parte rimovibile dell etichetta di garanzia ed incollatela sulla cartolina di richiesta di estensione di garanzia fornita con la centrale o il combinatore telefonico 2 Se state integrando un impianto esistente incollate l etichetta di garanzia sulla cartolina di richiesta di estensione di garanzia fornita con l apparecchiatura Mm 3 Apprendimento L apprendimento consente alla centrale del sistema di memorizzare il rivelatore di fumo Per poter effettuare l operazione di apprendimento la centrale deve trovarsi in modo installazione se si trova in modo uso per passare al modo installazione digitate POOO AD ATTENZIONE durante l apprendimento n meglio non posizionare il
14. control panels 4 2 Testing the radio e inter connected in a wired network of up to 40 detectors link at the chosen location A In stand alone mode it produces the following alarms and ANSIFIxing Tn indications throughout the smoke detection period 4 4 Installing several Red signal LED White detectors indicates the state indicator Built in audible alarm in a network of the detector LED Detector transmit a built in alarm sounds 5 Detector tests ting the smoke the ern lit on a continuous basis Manual cisabiing ceca spa a of the detector 44 inter connected lit audible alarm sounds 7 Indication 45 detectors 85 dB A at 3 m E a i Connected to a Hager alarm system it also activates Bat ig A immediately smoke is detected 8 Maintenance 46 triggering of the control panel siren and the alarm sirens in 8 1 Servicing the fire alarm modulation for 5 minutes detection head 46 e triggering of the telephone dialler 8 2 Changing the battery 47 triggering wired sirens 8 3 In case of any works ggering in the room 47 CAUTION it is recommended to replace the smoke 9 Technical data 48 detector subject to a regular and normal maintenance every 10 years The replacement date is indicated on back 10 User sheet 49 of the product 1 2 Description 2 Power supply Red signal LED Connect the lithium battery doo Stato respecting the polarity Test key T
15. luz durante m s de 10 min o bien 12 horas despu s de producirse Anomal a de alimentaci n en el detector Testigo rojo Testigo ATENCI N cuando detecta indicador del Sirena estado del detector blanco la bateria usada el detector s continua funcionando Detector en que se el testigo parpadea _ 2 tonos rapidos produce la anomalia cada 5 seg cada 60 seg perfectamente durante Otros detectores 30 dias Es aconsejable interconectados A reemplazarla cuando antes alambricamente Si la notificaci n sonora de esta anomal a se produce en un momento inoportuno es posible posponerla de 8 horas en los pr ximos 7 d as Para esto pulse la tecla test hasta el 1 tono Usted dispone de ese espacio de tiempo para reemplazar la bater a Anomal a de alimentaci n en la central Despu s de un comando del sistema la central se ala vocalmente bip anomalia alimentaci n detector X Anomal a de cabeza de detecci n sucia ATENCI N al detectar de la anomal a se recomienda limpiar lo m s r pido posible la cabeza de detecci n ver Mantenimiento Testigo rojo Testigo indicador del Sirena estado del detector blanco Detector en que se 8 parpadeos _ 8 tonos r pidos produce la anomal a cada 8 seg cada 58 seg Otros detectores interconectados al mbricamente Si la notificaci n sonora de esta anomal a se produce en un momento
16. most appropriate manner you are helping to protect the environment and human health If you would like additional information concerning the recycling of this product please contact your town city council nearest waste collection centre or the shop where you bought the product E Sumario 1 Presentaci n 52 1 1 Principio de funcionamiento 52 1P2IDeSCripclon 53 2 Alimentaci n 53 3 Programaci n s 54 4 Instalaci n del detector 55 4 1 Elecci n del emplazamiento 55 4 2 Test de alcance de radio en el lugar elegido 56 5 6 Us 9 Mantenimiento 4 3 Fijaci n 4 4 Instalaci n de varios detectores en red 58 Prueba del detector 59 Inhibici n voluntaria del detector 60 Senalizaci n De activaciones De anomal as 8 1 Mantenimiento de la cabeza de detecci n 62 8 2 Cambio de la bater a 63 8 3 En caso de obras en la casa 63 Caracteristicas 64 10 Ficha de utilizacion 65 1 Presentaci n 1 1 Principio de funcionamiento El detector ptico de humo est destinado a la detecci n de incendios de combusti n lenta que pueden durar varias horas antes de inflamarse Est destinado a la protecci n de partes privadas de edificios o residencias de viviendas Este dispositivo puede utilizarse e solo e
17. r pidos produce la anomal a cada 8 seg cada 58 seg Otros detectores interconectados al mbricamente Inhibici n voluntaria del detector Es posible desactivar voluntariamente el detector durante 15 min Esta funci n puede ser til en los casos siguientes ATENCI N para no despertarle la se al ac stica de las anomal as de alimentaci n o de cabecera de detecci n registrada durante la noche es inhibida La anomal a es entonces restituida o bien al volver la luz durante m s de 10 min o bien 12 horas despu s de su aparici n e si se realizan actividades en la estancia que puedan generar humo barrido de una habitaci n polvorienta deshollinamiento de una chimenea y provocar un disparo intempestivo de la alarma e para parar la alarma en caso de detecci n de humo no peligroso Para desactivar el detector pulsar la tecla test hasta el primer tono o hasta que la sirena integrada se pare El testigo de indicaci n de estado del detector parpadea cada 2 seg Testigo rojo indicador del estado del detector Testigo blanco Sirena Detector inhibido el testigo parpadea cada 2 seg Otros detectores A interconectados el Re alambricamente caga 11 599 ATENCION durante los siguientes 15 min el detector no podra detectar el humo ni disparar la alarma A los 15 min el detector retorna automaticamente a su estado operacional y el testigo de estado pa
18. the plastic cover prior to carrying out any work in the room after detector s installation 9 Technical data Technical data Residential radio smoke detector S151 22X Type of detection optical smoke detector Average coverage 50 m Installation Inside premises Power supply 3 6 V BatLi 26 or BatLi 25 lithium battery Battery life approximately 5 years under normal operation Red signal LED e state of the detector e alarm activations e faults White indicator LED emergency LED is turn on in the event of detection Built in audible alarm e gt 85 dB at 3 m In the event of detection e gt 75 dB at 3 min the event of test or signalling Wired interconnection of up to 40 detectors Length of the network maximum 400 m Maximum cable diameter 1 5 mm Radio link TwinBand 800 400 MHz Operating temperature 10 C to 55 C Protection class IP 32 Dimensions D x H 125 x 48 mm Weight 210g To obtain advice when installing your system or before returning equipment please contact the HAGER technical support team see telephone number at the back of the alarm system installation manual or www hagersupport co uk A team of qualified technicians will tell you what to do 10 User sheet pull out sheet for the user Be prepared for a fire e Plan an evacuation route e Prepare an evacuation plan for every bedroom e The least smoke is near the ground c
19. 006 95 CE conform ment aux normes europ ennes harmonis es suivantes R f rence produit 151 22X EN 300 220 2 V2 1 2 X EN 50130 4 95 A1 98 A2 2002 EN 60950 2006 EN 301489 1 V1 8 1 Ce produit peut tre utilis dans toute l UE l EEA et la Suisse Pad Pad gt lt Signature Patrick Bernard Directeur Recherche et D veloppement Crolles le 21 10 10 Le marquage CE appos sur ce produit atteste de sa conformit aux directives europ ennes qui lui sont applicables en particulier sa conformit aux sp cifications harmonis es de la norme EN 14604 en regards de la directive 89 106 CE relative aux produits de construction C 0333 CE 1 0333 Nous d clarons sur la base du certificat de conformit joint le concernant que la conformit du produit d sign ci dessus a t tablie pour r pondre aux exigences essentielles de la Directive DPC 89 106 CE amend e par la 93 68 CE conform ment la norme EN 14604 2005 et dispositions de l annexe ZA de cette m me norme Certificat de conformit n 0333 CPD292 004 D livr par AFNOR Certification 11 rue Fran ois de Pressens FR 93571 La plaine St Denis Cedex Signature Patrick Bernard Directeur Recherche et D veloppement Document non contractuel soumis modifications sans pr avis Traitement des appareils lec triques et lectro niques en fin de vie Applica
20. 95 CE in compliance with the following harmonised European Standards Products code 151 22X EN 300 220 2 V2 1 2 X EN 50130 4 95 A1 98 A2 2002 X EN 60950 2006 X These products can be used in all EU EEA Countries and Switzerland A Crolles 21 10 10 Signature PE Patrick Bernard Y Research amp Development Manager C 10 0333 As certified by the enclosed certificate of conformity we declare that the above mentioned product complies with the essential requirements of CPD Directive 89 106 CE together with amendment 93 68 CE in compliance with standard EN 14604 2005 and the provisions of appendix ZA of this same standard Certificate of Confirmity n 0333 CPD292 004 Delivered by AFNOR Certification 11 rue Fran ois de Pressens FR 93571 La plaine St Denis Cedex 22 Signature Me Patrick Bernard Research amp Development Manager Non contractual document may be modified without prior notice Waste processing of electrical and m electronic devices at the end of their ser vice life Applicable in European Union coun tries and other European countries with a waste collection system Used on products or product packaging this symbol indicates that the pro duct must not be thrown out with household waste lt must be taken to a waste collection point for electrical and electronic product recy cling When you make sure that this product is disposed of in the
21. NF292 DUE Caract ristiques certifi es essentielles 0333 Organisme Certiicateur couvertes par la marque NF AFNOR Certification www marque nf com Type de montage plafonnier ou mural Source d alimentation principale interne pile Lithium fournie Autonomie Certifi e NF 5 ans Dispositif interconnect oui filaire Pr vu pour installation dans un camping car non Raccordement a des dispositifs auxillaires externes non Liaison radio oui centrale d alarme Indicateur d alarme individuel oui Dispositif de neutralisation d alarme oui Centrales associ es certifi es NF amp A2P S303 22F S318 22F Les volets clients doivent tre conserv s toute la vie du produit Ce DAAF est associable aux centrales S303 22F et S318 22F certifi es NF amp A2P Afnor Certification F 93571 St Denis La Plaine Cedex http www marque nf com MM Sommario 1 Presentazione 1 1 Principio di funzionamento 20 1 2 Descrizione 21 2 Alimentazione 21 3 Apprendimento 22 4 Installazione del rivelatore 23 4 1 Scelta del luogo d installazione 23 4 2 Test del collegamento radio dalla posizione prescelta 24 4 3 Fissaggio 25 4 4 Installazione di pi rivelatori in rete 26 5 Test del rivelatore 27 6 Inibizione volontaria del rivelatore 28 7 Segnalazione 7 1 Degli
22. acuation pour toutes les pi ces e C est au sol qu il y a le moins de fum e sortez en rampant e Au retentissement de l alar me r veillez tout le monde e Pr voyez un point de rassemblement l ext rieur de l habitation e Evitez toute entr e inutile dans l habitation en feu e Appelez les pompiers En cas de travaux Il est interdit de peindre le d tecteur Si des travaux sont n cessaires apr s la pose le couvrir compl tement l aide de la protection plastifi e fournie Ne pas oublier de retirer la protection plastifi e la fin des travaux R sum des r actions et des signalisations de votre d tecteur Fonctionnement normal Voyant rouge de signalisation de gees Sonnerie l tat du d tecteur 5 1 clignotement Tous vos d tecteurs toutes les 10 5 D tection de fum e 1 Voyant rouge de signalisation de ies Sonnerie l tat du d tecteur D tecteur l origine Clignote d clenchement d une de la d tection ra e ent allum sonnerie int gr e continue de fum e p 85 dB A 3 m Autres d tecteurs d clenchement interconnect s allum d une sonnerie int gr e filairement modul e 85 dB A 3 m 1 R actions jusqu a la dissipation de la fum e Test du d tecteur 2 Voyant rouge de signalisation de yoan Sonnerie l tat du d tecteur 5 1 s de sonnerie D tecteur Clignote 4 A l origine du test rapidement allum
23. ager le d tecteur de son socle en le tournant dans le sens inverse des aiguilles d une montre jusqu au clic de d verrouillage 2 Remplacer la pile usag e 3 Verrouiller le d tecteur sur son socle cf Fixation 4 Proc der un test cf Test du d tecteur Si Pouverture optionnelle du d tecteur est verrouill e cf Fixation 1 Introduire un tournevis lame plate dans cette encoche 2 D gager le d tecteur de son socle en le tournant dans le sens inverse des aiguilles d une montre jusqu au clic de d verrouillage 3 Remplacer la pile usag e 4 Verrouiller le d tecteur sur son socle cf Fixation 5 Proc der a un test cf Test du d tecteur 8 3 En cas de travaux Il est interdit de peindre le d tecteur Si des travaux sont n cessaires apr s la pose le couvrir compl tement l aide de la protection plastifi e fournie ATTENTION ne pas oublier de retirer la protection plastifi e la fin des travaux Risque d explosion si le bloc lithium n est pas remplac correctement Remplacer le bloc lithium par un bloc lithium du m me type BatLi 26 ou BatLi 25 3 6 V D poser le bloc lithium usag dans les lieux pr vus pour le recyclage 9 Fiche d utilisation volet d tachable a remettre au client Se pr parer l incendie e Pr voyez un itin raire d vacuation e Pr parez un plan d v
24. ble dans les pays de l Union Europ enne et autres pays europ ens dis posant d un syst me de collecte Ce symbole appos sur le produit ou sur son emballage indique que ce produit ne doit pas tre trait avec les d chets m nagers Il doit tre remis a un point de collecte appropri pour le recyclage des quipements lec triques et lectroniques En vous assurant que ce pro duit est bien mis au rebut de mani re appropri e vous aiderez a pr venir les cons quences n gatives pour l environnement et la sant humaine Pour toute information suppl mentaire au sujet du recyclage de ce produit vous pouvez vous adresser votre municipa lit d chetterie ou au magasin o vous avez achet le produit Eco organisme Recyclum NF D tecteurs avertisseurs autonomes de fum e La marque NF appliqu e aux D tecteurs Autonome Avertisseur de Fum e DAAF c est Passurance de la s curit et d une qualit constante contr l e par des sp cialistes Par des contr les rigoureux et exhaustifs syst me de management de la qualit du titulaire contr le des fabrications audits et essais de surveillance elle apporte au consommateur toutes les garanties de conformit des produits certifi s La marque NF DAAF atteste la conformit du produit au r f rentiel de certification NF292 Caract ristiques essentielles certifi es C 10 MO R f rentiel de certification
25. canalature della testa di rilevazione devono essere spolverate mediante un aspirapolvere almeno una volta all anno o ad ogni segnalazione di testa di rilevazione intasata v Segnalazione di anomalie ATTENZIONE se la segnalazione di testa di rilevazione intasata permane anche dopo la rimozione della polvere sostituite il rivelatore E consigliabile pulire il rivelatore utilizzando un panno morbido Non utilizzate n alcol n acetone per la pulizia 8 2 Cambio della pila Se il rivelatore non bloccato alla base v Fissaggio 1 Rimuovete il rivelatore dalla base ruotandolo in senso antiorario fino al clic di apertura 2 Sostituite la pila scarica 3 Rimettete il rivelatore sulla base v Fissaggio 4 Effettuate un test del rivelatore v Test del rivelatore Se il rivelatore bloccato alla base v Fissaggio 1 Introducete un cacciavite piatto nell incavo indicato in figura 2 Rimuovete il rivelatore dalla base ruotandolo in senso antiorario fino al clic di apertura 3 Sostituite la pila scarica 4 Rimettete il rivelatore sulla base v Fissaggio 5 Effettuate un test del rivelatore v Test del rivelatore 8 3 In caso di lavori E assolutamente vietato dipingere il rivelatore Se si rende necessario effettuare lavori sulle pareti dopo l installazione del rivelatore necessario coprire completamente il riv
26. cf Notice d installation de la centrale Message d identification vocal des d tecteurs radio 4 Pose du d tecteur ATTENTION respecter une distance d au moins 2 m entre chaque produit except entre deux d tecteurs 4 1 Choix de l emplacement Le d tecteur doit tre plac e dans les pi ces pr sentant un risque d incendie salles de s jour avec chemin e chambres d enfants greniers ou sous sols habit s e de pr f rence au centre du plafond e l cart des bouches de ventilation qui risquent de disperser la fum e e a plus de 50 cm de tout obstacle mur cloison poutre e chaque extr mit d un couloir si sa longueur est sup rieure 10m Si la fixation sur un plafond horizontal est impossible le fixer e a plus de 50 cm de tout angle de la pi ce Fig 1 e une distance comprise entre 50 et 60 cm du plafond Fig 1 e loign de sources ventuelles de perturbations lectriques compteur lectrique coffret m tallique e en cas de fixation sur une paroi m tallique intercaler une cale en mat riau non magn tique bois ou plastique Le d tecteur ne doit pas tre plac e directement sur une surface m tallique Exemples d installations D tecteurs de fum e e a proximit de tubes fluorescents e dans des pi ces trop poussi reuses e dans une pi ce ou la temp rature risque de descendre sous 10 C ou monter au des
27. che al termine del ciclo di vita applica bile nei paesi dell Unione Europea e negli altri paesi europei che dispongono di un sistema di raccolta dif ferenziata Questo sim bolo apposto sul prodotto o sul suo imballaggio indica che il prodotto non deve essere trattato come un rifiuto comune Deve essere riportato ad un punto di raccolta appro priato per il riciclaggio dei componenti elettrici ed elettronici Assicurandovi che questo prodotto sia correttamente avviato al riciclaggio contribuirete a prevenire le conseguenze negative per l ambiente e per la salute delle persone Per qualsiasi informazione supplementare riguardo al riciclaggio di questo pro dotto potete fare riferi mento al vostro comune di residenza al centro di rac colta dei rifiuti o al distribu tore presso cui stato acquistato il prodotto Summary 1 Introduction 1 Introduction 36 1 1 Operation principle 1 1 Operation principle 36 The optical smoke detector is especially suited for detecting 1 2 Description 37 slow starting fires that may smoulder for several hours before 2 Power SUPplY c gt 37 breaking out It is designed to protect the private areas of A buildings or apartment blocks 3 Programming 38 can be 4 Installing the detector 39 e used as a stand alone unit 4 1 Choosing the right e integrated into a Hager alarm system with TwinBand place 39
28. che test de d tection avec une bombe test r f TESTFUM pendant 1 2 s Dans un d lai de 10 s maximum le d tecteur met une s rie de bip de plus en Voyant rouge Vi plus rapproch jusqu au AEE loyant gt de signalisation de blanc er d clenchement qui intervient l tat du d tecteur A dans un temps de 12 22 s 1 s de sonnerie Si la s rie de bip ne D tecteur Clignote allum 75 dB A a3 m p l origine du test rapidement suivi de 1 s de pause s enclenche pas la concentration de fum e dans Autres d tecteurs Clignote 1 s de sonnerie la t te de d tection n est pas interconnect s se allum 75 dB A 3 m suffisante pulv riser amp filairement suivi de 2 s de pause nouveau l aide de la bombe test Connect a un syst me d alarme Hager il provoque en plus des l appui sur la touche test plus de 10 s e le d clenchement de la centrale et des sir nes du syst me de s curit en modulation incendie pendant 5 min e le d clenchement du transmetteur t l phonique e le d clenchement des sir nes filaires Arr ter les sir nes et v rifier la m morisation de l alarme par la centrale cf Signalisation Pour ce type de test les r actions du d tecteur sont d crites au paragraphe Principe de fonctionnement ATTENTION e Ne jamais se servir d une flamme nue pour tester le d tecteur de fum e e Ces essais sont r aliser au
29. d the u Teone onog detectors Y i After the 15 min disable period has passed the detector is automatically reset to normal operation with the detector state indicator flashes every 10 s CAUTION to leave shut down mode more quickly press the test button for about 10 s until the alarm sounds see reaction in the sensor Test chapter CAUTION for the 15 min disable period the detector will not detect any smoke nor release any audible alarm 7 Indication 7 1 Alerts When your alarm system is deactivated the base unit will report the problem with the voice message beep date time fire alarm remote control n 7 2 Faults CAUTION in order not to wake you up alarms resulting from mains supply problems or dirty sensors are shut down during the night Any errors are corrected after daybreak within 10 minutes i e 12 hours after the event Power supply fault on the detector Red signal LED White indicates the state indicator Built in audible alarm of the detector LED Detector at the source the unit flashes once 7 the unit releases of the fault indication every 5 sec 2 fast beeps every 60 sec Other wired inter connected li detectors CAUTION when a battery fault becomes evident the detector continues to function perfectly for 30 days It is advisable to replace the battery as soon as possible If the sound indication of the po
30. e aparatos el ctricos mua Y electr nicos al final de su vida til Aplicable a los pa ses de la Comunidad Europea y a otros pa ses con un siste ma de recogida Este sim bolo dispuesto sobre el producto o sobre el emba laje indica que el producto no debe ser tratado con los desechos Debe ser remitido a un punto de recogida apropiado para el reciclado de materiales el ctricos y electr nicos Asegur ndose que este producto cuenta con la recogida apropiada ayu dar a prevenir las conse cuencias negativas para el medio ambiente y la salud humana Para cualquier informaci n complementa ria sobre reciclado de este producto puede remitirse a su ayuntamiento prove edor o instalador a quien haya comprado el produc to shager Hager SAS T l 333 88 49 50 50 132 Boulevard d Europe www hagergroup net BP 78 F 67212 OBERNAI CEDEX a Ne A E A CN A yA di NIC Hager 12 2010 4285201007
31. e d alarme Hager avec centrale TwindBand e interconnect dans un r seau filaire de 40 d tecteurs maxi Autonome il provoque pendant la dur e de d tection de fum e Voyant rouge de signalisation de ee Sonnerie l tat du d tecteur D tecteur l origine Clignote d clenchement d une de la d tection rai i ent allum sonnerie int gr e continue de fum e p 85 dB A 3 m Autres d tecteurs d clenchement interconnect s allum d une sonnerie int gr e filairement modul e 85 dB A 3 m Connect un syst me d alarme Hager il provoque en plus d s la d tection de fum e e le d clenchement de la centrale et des sir nes radio du syst me de s curit en modulation incendie pendant 5 min e le d clenchement du transmetteur t l phonique e le d clenchement des sir nes filaires ATTENTION il est recommand de remplacer le d tecteur de fum e sous r serve d un entretien r gulier et normal tous les 10 ans La date de remplacement est indiqu e au dos du produit o 1 2 Descriptif 2 Alimentation Voyant rouge Connecter le bloc lithium en de signalisation respectant le sens de de l tat du d tecteur branchement Touche test Le voyant rouge de signalisation clignote pendant 15s puis ensuite 1 fois toutes les 10 s indiquant un fonctionnement normal du d tecteur Voyant blanc clairage de secours en cas de d tect
32. e ne pas vous r veiller la signalisation sonore des anomalies d alimentation ou de t te de d tection encrass e survenant la nuit est inhib e L anomalie est alors restitu e soit au retour de la lumi re pendant plus de 10 min soit 12 h apr s l apparition Il est possible de d sactiver le d tecteur pour une dur e de 15 min e en pr vention d activit s pouvant g n rer de la fum e balayage d une pi ce poussi reuse ramonage d une chemin et donc des d clenchements intempestifs e pour arr ter l alarme en cas de d tection de fum e non dangereuse Pour ce faire appuyer sur la touche test jusqu au 1 bip ou jusqu ce que le d tecteur arr te sa sonnerie int gr e Le voyant de signalisation d tat du d tecteur clignote alors toutes les 2s Voyant rouge de signalisation de l tat du d tecteur Voyant blanc Sonnerie D tecteur inhib 1 clignotement toutes les 2 s Autres d tecteurs interconnect s filairement 1 clignotement toutes les 10 s ATTENTION pendant ces 15 min le d tecteur ne pourra reconna tre aucunes fum es ni g n rer d alarmes Au bout de ces 15 min le d tecteur redevient automatiquement op rationnel le voyant de signalisation d tat du d tecteur clignote toutes les 10 s Caract ristiques techniques D tecteur avertisseur de fum e LS radio S151 22X Type de d tection d tecteur optique de fu
33. e pins and screw Fixing with flush mounting box 1 For boxes of 60 mm diameter use holes marked 0 2 For boxes of 85 mm diameter use holes marked 3 3 Fix the base using suitable screws CAUTION for passing the interconnecting Diameter 60 fixing holes cables remove the 2 fixing spacers and insert them between the ceiling and the Alignment position in the key test mounting base by covering the 2 selected fixing holes Fixing spacers Diameter 85 fixing holes Optional locking of the detector on the mounting base Optional locking is designed to prevent unauthorized dismounting of the detector Using cutting pliers cut the locking nipple CAUTION opening will now be possible only by means of a flat blade screwdriver Locking nipple Align the 2 locating arrows marked on the mounting base and the detector then lock the unit by turning clockwise CAUTION the detector cannot be fixed to the base if the battery is not properly seated Do not use force 4 4 Installing several detectors in a network It is possible to inter connect up to 40 detectors to enable alarm activation over the whole range of smoke detectors of the home You can therefore be sure of being warned if smoke is detected in a room far away from the room in which you are in 1 After the detector s mounting base has been installed see Mounting unfasten the connector block Connector block 2 Then wire as follows
34. ectores 4 1 Elecci n del emplazamiento El detector tiene que estar e en lugares con riesgo de incendio salas con chimenea habitaciones de ni os desvanes o bodegas habitadas y preferentemente en el centro del techo e lejos de las salidas de ventilaci n que pueden dispersar el humo e a m s de 50 cm de todo obst culo pared columna maestra viga e en cada extremo del pasillo si ste supera los 10 m de longitud Si la instalaci n no es posible en un techo horizontal instalar el detector e a m s de 50 cm de cualquier ngulo de la estancia Fig 1 e auna distancia comprendida entre 50 y 60 cm del techo Fig 1 e lejos de toda fuente de perturbaciones el ctricas contador el ctrico caja met lica e en caso de instalaci n en una pared met lica intercalar una cu a de un material antimagn tico madera o pl stico El detector no debe estar e directamente en una superficie met lica e cerca de tubos fluorescentes Ejemplos de instalaciones Detectores de humo e en habitaciones demasiado polvorientas e en una habitaci n donde la temperatura pueda descender a 10 C o subir a m s de 55 C ya que esto puede provocar un funcionamiento incorrecto del detector e a menos de 1 m de las salidas de calefacci n de aire acondicionado o de ventilaci n ya que esto podria provocar la dispersi n del humo a menos de 6 m de una chimenea o de una estufa de madera ya que el h
35. el sentido contrario de las agujas del reloj hasta su desbloqueo 2 Quitar el detector de su base Para esto hacerlo girar en el sentido contrario de las agujas del 2 Reemplace la bater a reloj hasta su desbloqueo ATENCI N no olvide retirar Usada 3 R i ia Baten la protecci n al final de las Reemplace la bater a 3 Bloquear de nuevo el w a detector en su base ver Fijaci n 4 Bloquear de nuevo el detector en su base ver Fijaci n 5 Efectuar una prueba ver Prueba del detector 4 Efectuar una prueba ver Prueba del detector ATENCI N hay riesgo de explosi n si la bater a no se cambia correctamente Cambiarla por otra del mismo tipo BatLi26 o BatLi 25 3 6 V Deposite las bater as usadas dentro en los recipientes de reciclaje ES 9 Caracteristicas Caracteristicas t cnicas Detector de humo radio S151 22X Tipo de detecci n detector ptico de humo Superficie promedio cubierta 50 m Uso interior Alimentaci n bater a de 3 6 V BatLi26 o BatLi 25 Autonom a 5 a os en uso normal Testigo rojo de se alizaci n e del estado del detector e de los disparos de la alarma e de las anomal as Testigo blanco encendido de un halo lum nico de emergencia Sirena integrada e gt 85 dB a 3 m en caso de detecci n e gt 75 dB a 3 m en caso de prueba o de indicaci n de una anomalia Interconexi n al mbrica hasta
36. elatore con l apposita copertura plastificata fornita ATTENZIONE ricordate di rimuovere la protezione plastificata al termine dei lavori Rischio di esplosione se la pila al litio non sostituita correttamente Sostituite la pila al litio con una dello stesso tipo BatLi 26 o BatLi 25 3 6 V Gettate poi la pila al litio scarica negli appositi contenitori D 9 Caratteristiche Caratteristiche tecniche Rivelatore ottico di fumo via radio S151 22X Tipo di rivelazione rivelatore ottico di fumo Copertura media 50 m Uso interno Alimentazione pila al litio BatLi 26 o BatLi 25 3 6 V Autonomia 5 anni in uso normale Spia rossa di segnalazione e dello stato del rivelatore e degli allarmi e delle anomalie Spia bianca illuminazione di soccorso in caso di rivelazione Suoneria integrata e gt 85 dB a 3 min caso di rivelazione e gt 75 dB a 3 min caso di test o di segnalazione di un anomalia Collegamento filare 40 rivelatori massimo Lunghezza della rete filare Diametro del cavo 400 m massimo 1 5 mm massimo Trasmissione radio Doppia Frequenza 800 400 MHz Temperatura di funzionamento 10 Ca 55 C Indice di protezione IP 32 Dimensioni D x H 125 x 48 mm Peso 210g Per avere consigli e chiarimenti durante l installazione o prima di rispedire qualunque prodotto difettoso contattate l assistenza Tecnica Assistenza tecnica
37. gement Ne pas forcer 4 4 Pose de plusieurs d tecteurs en r seau Il est possible d interconnecter jusqu a 40 d tecteurs entre eux afin de permettre le d clenchement de l alarme sur l ensemble des d tecteurs de fum e de l habitation Vous tes ainsi s rs d tre pr venus si la fum e se d clare dans une pi ce loign e de celle dans laquelle vous vous trouvez 1 Apr s avoir fix le socle des d tecteurs cf Fixation d clipser le bornier de connexion Bornier de connexion 2 Puis r aliser le cablage suivant Borniers o de c blage o Non utilis LAO Signal Masse Pour un fil de section de 1 5 mm la longueur totale du r seau ne doit pas d passer 400 m 3 Reclipser le bornier de connexion sur le support 4 Verrouiller le d tecteur sur son socle cf Fixation ATTENTION ne raccorder entre eux que des d tecteurs de m me modele 5 Test du d tecteur La sonnerie est att nu e lors d un test manuel du d tecteur Test de d tection de fum e n anmoins il est conseill de pr venir au pr alable Pulv riser travers les fentes le voisinage et de prendre les pr cautions n cessaires pour environs 10 cm de la t te viter les risques de troubles auditifs Test manuel Appuyer 10 s environ sur la touche test jusqu au d clenchement de la sonnerie int gr e Le d tecteur provoque jusqu au rel ch de la tou
38. he red indicator lamp flashes for 15 sec then once every 10 sec signalling the normal operation of the detector White indicator LED an emergency LED is turned on in the event of smoke detection Product replacement date Guarantee sticker Programming k ey 0 Lithium battery connector Guarantee stickers 1 Detach the removable pre cut section of the guarantee sticker and stick it on to the guarantee extension request supplied with the control panel or the telephone dialler 2 If you are adding to an existing system stick the guarantee sticker on to the extension request supplied with the product 3 Programming Programming enables the smoke detector to be recognised by the control panel To programme the smoke detector the control panel must be in installation mode If it is not press A DOO CAUTION during recognition programming q 5 the product to be programmed for use nou ade with the control panel does not need to be placed next to it In fact we recommend you place the product at a short distance from the control panel at least 2 m away then press 900 E XX engineer installer code Carry out the programming sequence described below beep fire detector n X e then ZA i gt q D 10 s max i Press then on the Press amp hold the programming key 0 control panel keypad for 10 sec until the cont
39. inoportuno es posible posponerla de 8 horas en los pr ximos 7 d as Para esto pulse la tecla test hasta el 1er tono Dispone as de este espacio de tiempo para limpiar el detector Anomal a radio en la central Despu s de un comando del sistema la central se ala vocalmente bip anomal a radio detector X 8 Mantenimiento 8 1 Mantenimiento de la cabeza de detecci n El mantenimiento cont nuo del detector es de capital importancia para su correcto funcionamiento Las ranuras de la cabeza de detecci n deben ser limpiadas con un aspirador por lo menos una vez por a o o a cada notificaci n de cabeza de detecci n sucia ver Se alizaci n de aver as ATENCI N si la notificaci n de cabeza de detecci n sucia persiste despu s de su limpieza cambie el detector ATENCI N le aconsejamos limpiar el detector con un trapo suave No utilice alcohol ni acetona para la limpieza 8 2 Cambio de la bater a Si la abertura opcional del 8 3 En caso de obras Si la abertura opcional detector est bloqueada en la casa del detector no est ver Fijacion No pintar el detector en bloqueada ver Fijaci n 1 Introducir un destornillador ning n caso 1 Quitar el detector de su de hoja plana en la ranura Si se deben efectuar obras en la casa despu s de la instalaci n cubrir completamente el detector con la protecci n de pl stico incluida base Para esto hacerlo girar en
40. integrado en un sistema de alarma Hager con central TwindBand e interconectado en una red alambrica de hasta 40 detectores Aut nomo provoca durante el tiempo de detecci n de humo Testigo rojo indicador del la Sirena estado del detector disparo de una alarma rosie si parpadeo r pido activado integrada continua 85 dB A a 3 m Otros detectores disparo de una alarma interconectados activado integrada modulada alambricamente 85 dB A a 3 m Conectado a un sistema de alarma Hager tambi n act a como detector de humos e el disparo de la central y de las sirenas del sistema de seguridad en modulaci n incendio 5 min e el disparo del transmisor telef nico e el disparo de las sirenas conectadas al mbricamente ATENCI N se recomienda cambiar el detector de humo cada 10 a os realizando un mantenimiento regular y normal La fecha de sustituci n se indica en la parte trasera del producto 1 2 Descripci n Testigo rojo indicador del estado del detector Tecla test Testigo blanco encendido de emergencia en caso de detecci n de humo Fecha de sustitucion del producto Etiqueta de garantia Tecla de programaci n O Conector de la bater a Etiqueta de garant a 1 Suelte la parte precortada de la etiqueta de garant a y p guela sobre la solicitud de extensi n de garant a incluida con los documentos de la central o del transmisor telef
41. ion de fum e Vignette Date de de garantie remplacement du produit Ie Connecteur programmation 0 elit Vignette de garantie 1 D tacher la partie pr d coup e amovible de la vignette de garantie et la coller sur la demande d extension fournie avec la centrale ou le transmetteur t l phonique 2 En cas de compl ment du syst me coller la vignette de garantie sur la demande d extension fournie avec le produit 3 Apprentissage L apprentissage permet d tablir la reconnaissance du d tecteur de fum e par la centrale Pour effectuer l op ration d apprentissage du d tecteur de fum e la centrale doit tre en mode installation dans le cas contraire composer A DOO D DP ATTENTION lors de l apprentissage il est 5 inutile de placer le produit apprendre Ri de ma tre proximit de la centrale au contraire nous vous conseillons de vous loigner quelque peu placer le produit au moins 2 m de la centrale puis composer 2000 e o os i code installateur R aliser la s quence d apprentissage d crite ci dessous i C bip d tecteur incendie n X 10 s max i Appuyer sur puis Maintenir l appui sur la touche de programmation 0 du clavier de la centrale pendant 10 s jusqu la r ponse de la centrale Il est possible d enregistrer un message personnalis permettant d identifier vocalement le d tecteur incendie
42. l medesimo modello al g o Flo Fo O Massa Mm 5 Test du d tecteur La suoneria del rivelatore attenuata in caso di test manuale del rivelatore comunque consigliabile avvisare il vicinato e prendere le precauzioni necessarie per evitare rischi di disturbi all udito Test manuale Tenete premuto per circa 10 secondi il pulsante di test fino all attivazione della suoneria integrata Il rivelatore al rilascio del pulsante di test reagisce come descritto nella tabella seguente Spia rossa Spia di segnalazione bianca Suoneria integrata 1 secondo di suoneria Rivelatore lampeggia Poriai accesa a 75 dB A a 3 m seguito alPorigine del test rapidamente da 1 secondo di pausa Altri rivelatori i 1 secondo di suoneria collegati ampeggia accesa a 75 dB A a 3 m seguito in rete filare P da 2 secondi di pausa Abbinato ad un sistema d allarme logisty expert di Hager sicurezza provoca inoltre e l attivazione della sirena incorporata alla centrale e le sirene d allarme in modulazione incendio per 5 minuti e l attivazione del combinatore telefonico e l attivazione delle sirene filare Fermate i mezzi d allarme e verificate che la centrale abbia memorizzato l allarme v Segnalazione ATTENZIONE Test di rivelazione Nebulizzate attraverso le aperture a circa 10 cm di distanza dalla testa di rilevazione
43. m e Couverture moyenne 50m Usage int rieur Alimentation bloc lithium 3 6 V BatLi 26 ou BatLi 25 Autonomie 5 ans environ en usage normal Voyant rouge de signalisation e de l tat du d tecteur e des d clenchements e des anomalies Voyant blanc clairage de secours en cas de d tection Sonnerie int gr e e gt 85 dB a3 men cas de d tection e gt 75 dB 3 m en cas de test ou de signalisation d une anomalie Interconnexion filaire 40 d tecteurs max Longueur du r seau 400 m max Diam tre du c ble 1 5 mm max Liaison radio TwinBand 800 400 MHz Temp rature de fonctionnement 10 C 55 C Indice de protection m canique IP 32 Dimensions D x H 125 x 48 mm Poids 210g Pour obtenir des conseils lors de l installation ou avant tout retour de mat riel contactez l assistance technique Hager GX TO 825 899 137 copuis1 poste fie 0 15 TTC min Une quipe de techniciens qualifi s vous indiquera la proc dure suivre www hager fr D CLARATION DE CONFORMIT C Fabricant Hager Security SAS 10 Adresse F 38926 Crolles Cedex France Type de produit D tecteur avertisseur de fum e LS radio Marque Hager Nous d clarons sous notre seule responsabilit que le produit auquel se r f re cette d claration est conforme aux exigences essentielles des directives suivantes e Directive R amp TTE 99 5 CE e Directive Basse Tension 2
44. mento accettabile Fig 2 d gt 50cm 4 2 Test del collegamento radio dalla posizione prescelta ATTENZIONE per poter effettuare questo test la centrale deve trovarsi in modo installazione v apprendimento 1 Premete il pulsante di programmazione 0 o il pulsante test fino a quando si attiva la suoneria integrata e collegamento radio corretto segnalato dal messaggio vocale bip rivelatore incendio X e collegamento radio non corretto nessun messaggio vocale In questo caso spostate il rivelatore in una posizione diversa 2 Riportate la centrale in modo uso digitando Le DDA codice E aD 4 3 Fissaggio Fissaggio standard 1 Collocate la base del rivelatore nella posizione prevista e segnate con una matita la posizione dei 2 fori di fissaggio identificati dalle diciture 69 o 63 2 Forate con un trapano nei punti segnati punta di 5 mm 3 Fissate la base con tasselli e viti appropriate Fissaggio su di una scatola da incasso 1 Per scatole da incasso di diametro 60 mm utilizzate i fori di fissaggio identificati con 9 2 Per scatole da incasso di diametro 85 mm utilizzate i fori di fissaggio identificati con 63 3 Fissate la base con tasselli e viti appropriate ATTENZIONE In caso di collegamento filare Si fissaggio diametro 60 mm tra rivelatori per consentire il passaggio dei Segno di riferimento per l allineamento del pulsante di test cavi staccate i due spe
45. min e el disparo del transmisor telef nico e el disparo de las sirenas conectadas al mbricamente Parar las sirenas y verificar la memorizaci n de la alarma por la central ver Se alizaci n ATENCI N e No utilizar nunca una llama para testar el detector de humo Testigo rojo Testigo el detector emitir una serie de indicador del irena tonos que cada vez se ire del pid bianco a q 4 4 di deal escuchar n m s seguido hasta Isparo de la alarma j El detector en el arpadeo r pido activado durante 1 seg 75 dB A que dion la eel ere que origen de la prueba PAP p a 3 m seguido ocurrir en un lapso de 12 a de 1 seg de pausa 22 segundos disparo de la alarma Si el detector no emite ning n Otros detectores i A interconectados parpadeor pido activado durante Ps K BA meure pe e al mbricamente de 2 seg de pausa N cabeza de detecci n es insuficiente y ser necesario realizar una nueva pulverizaci n con la bomba de prueba Para este tipo de test ver las reacciones descritas del detector en el p rrafo Principios de funcionamiento e Estas pruebas deben efectuarse por lo menos una vez por mes especialmente despu s de un largo per odo de ausencia 6 Inhibici n voluntaria del detector Es posible desactivar voluntariamente el detector por una ATENCI N durante los durante 15 min Esta funci n puede ser til en los casos siguientes 15 minutos el siguientes detector no podr de
46. minal de conexi n ATENCI N el detector Terminal de conexi n no puede ser bloqueado en su base si la pila 2 Conectar los cables de la manera siguiente no est en su alojamiento No lo fuerce por favor Bornes o 5 de conexi n o Ho le No utilizado io Se al Tierra Para un cable de 1 5 mm de secci n la longitud total de la red no debe sobrepasar los 400 m 3 Encajar de nuevo el terminal de conexi n en el soporte 4 Bloquear el detector en su base ver Fijaci n ATENCI N interconectar solamente detectores del mismo modelo 58 ES 5 Prueba del detector La sirena puede ser atenuada durante la prueba manual del Prueba de detecci n detector sin embargo se aconseja informar con tiempo a los Con una bomba de prueba ref vecinos y tomar las precauciones necesarias para evitar todo TESTFUM realizar una riesgo de lesi n auditiva pulverizaci n a trav s de las Test manual ranuras a Men Mantener pulsada durante 10 segundos la tecla Test hasta ci de si cabeza que se dispare la sirena integrada e detecci n durante 1 a e Ye 2 segundos La prueba dura hasta que se suelte la tecla Test En 10 segundos como maximo Conectado a un sistema de alarma Hager pulsando la tecla test durante mas de 10s ademas e el disparo de la central y de las sirenas del sistema de seguridad en modulaci n incendio 5
47. moins une fois par mois et notamment apr s une longue absence 6 Inhibition volontaire du d tecteur i est possible de d sactiver le d tecteur pour une dur e de ATTENTION pendant ces Smin cas a 45 min le d tecteur ne e en pr vention d activit s pouvant g n rer de la fum e pourra reconna tre aucune balayage d une pi ce poussi reuse ramonage d une fum e ni g n rer d alarme chemin et donc des d clenchements intempestifs e pour arr ter l alarme en cas de d tection de fum e non dangereuse Pour ce faire appuyer sur la touche test jusqu au 1 bip ou jusqu a ce que le d tecteur arr te sa sonnerie int gr e Le voyant de signalisation d tat du d tecteur clignote alors toutes les 2s Voyant rouge de signalisation de voyant Sonnerie l tat du d tecteur D tecteur 1 clignotement _ n inhib toutes les 2 s Autres d tecteurs A interconnect s oe gt filairement Au bout de ces 15 min le d tecteur redevient automatiquement op rationnel le voyant de signalisation d tat du d tecteur clignote toutes les 10 s ATTENTION pour sortir plus rapidement du mode inhibition appuyer 10 s environ sur la touche Test jusqu au d clenchement de la sonnerie int gr e cf r action au chapitre Test du d tecteur 7 Signalisation 7 1 des d clenchements A la mise a l arr t la centrale restituera ce d clenchement par le message v
48. mpossibile fissate il rivelatore ad almeno 50 cm dagli angoli del locale Fig 1 e ad una distanza dal soffitto compresa tra 50 e 60 cm Fig 1 e lontano da eventuali sorgenti di disturbo elettromagnetico quadro elettrico e in caso di installazione su di una parete metallica inserite uno spessore in materiale isolante legno o plastica Il rivelatore non deve essere installato e direttamente su di una superficie metallica e in prossimit di tubi fluorescenti Esempi di installazione Rivelatori di fumo e in locali troppo polverosi e in un locale in cui la temperatura ambientale possa scendere al di sotto dei 10 C o al di sopra dei 55 C evento che potrebbe causare malfunzionamenti del rivelatore e a meno di 1 metro da bocchette di riscaldamento di refrigerazione o di aerazione il fumo potrebbe essere disperso e a meno di 6 metri da un camino o una stufa aD a legna che potrebbero causare falsi allarmi e in un locale in cui siano presenti fumi da cucina o vapore d acqua che potrebbero causare falsi allarmi e in un locale in cui possa essere presente elevata umidit o condensa di vapori evitate bagni lavanderie e al vertice di un soffitto ad ogiva a forma di A dove una sacca d aria potrebbe impedire al fumo di arrivare al rivelatore Fig 2 Esempi di fissaggio Fig 1 d gt 50cm Posizionamento suggerito 60 cm gt d gt 50 cm Posiziona
49. ms rings i the LED flashes A for sec 75 dB A detectors quickly at a 3 m distance then stops for 2 sec for longer than 10 sec and then released 2 The detector s respond until test button is pressed and held pressed Battery fault indication Red signal LED White indicates the state indicator Built in audible alarm of the detector LED Detector at the source the unit flashes once the unit releases of the fault indication every 5 sec 2 fast beeps every 60 sec Other wired inter connected detectors Indication of dirt on the detection head To prevent users from being disturbed at inconvenient times audible indications of a battery fault or dirt on the detection head can be delayed for 8 hours over a maximum period of 7 days by holding the test button pressed until the first beep sounds You should contact your installation engineer within this same period in order to rectify the problem Red signal LED White indicates the state indicator Built in audible alarm of the detector LED Detector at the source _ the unit flashes 8 times the unit releases of the fault indication over an 8 sec period 8 fast beeps every 58 sec Other wired inter connected detectors Manual disabling of the detector It is possible to disable the detector for a 15 min period e prior to activities likely to produce smoke Sweeping of a dusty room of a chimney and cau
50. ntenance de l anomalie toutes les 8 s Voyant rouge de signalisation de ovant Sonnerie l tat du d tecteur D tecteur l origine 8 clignotements 8 bips rapide toutes les 58 s Autres d tecteurs interconnect s filairement Si la signalisation sonore de l anomalie de t te de d tection encrass e appara t un moment inopportun il est possible de la reporter de 8 h sur une dur e maximale de 7 jours en appuyant sur la touche test jusqu au 1 bip Vous disposez ainsi de ce laps de temps pour nettoyer le d tecteur Anomalie radio sur la centrale Apr s une commande syst me la centrale signale vocalement Bip anomalie radio d tecteur n X 8 1 Entretien de la t te de d tection L entretien r gulier du d tecteur est d une importance essentielle Les fentes de la t te de d tection doivent tre d poussi r es l aide d un aspirateur au moins une fois par an ou chaque signalisation de t te de d tection encrass e cf Signalisation des anomalies ATTENTION si la signalisation de t te de d tection encrass e persiste apr s d poussi rage remplacer le d tecteur Nous vous conseillons de nettoyer le d tecteur l aide d un chiffon doux N utilisez ni alcool ni ac tone pour le nettoyage 8 2 Changement de l alimentation Si l ouverture optionnelle du d tecteur n est pas verrouill e cf Fixation 1 D g
51. o 85 dB A a 3 m Otros detectores disparo de una alarma interconectados Li activado integrada modulada alambricamente 85 dB A a 3 m 1 Reacciones hasta la desaparici n del humo Test manual del detector 2 Testigo rojo i indicador del mengo Sirena estado del detector disparo de la alarma El detector en el en durante 1 seg 75 dB A origen de la prueba parpadeo rapido activado a 3 m seguido de 1 seg de pausa disparo de la alarma Otros detectores interconectados parpadeo r pido activado de na SdB A al mbricamente eg de 2 seg de pausa test hasta soltar esta tecla 2 Reacciones seguidas a una pulsaci n superior a 10 seg sobre la tecla Se alizaci n de anomalia de alimentaci n Si la se alizaci n sonora de Testigo rojo indicador del estado del detector Testigo blanco Sirena Detector en que se produce la anomal a el testigo parpadea cada 5 seg 2 tonos r pidos cada 60 seg Otros detectores interconectados al mbricamente Se alizaci n de anomal a de cabeza de detecci n empotrada defecto de alimentaci n o de cabeza de detecci n aparece en un momento inoportuno es posible retrasarla 8 hrs sobre la duraci n m xima de 7 d as pulsando la tecla test hasta el primer bip Dispone as de este espacio de tiempo para avisar a su instalador Testigo rojo 5 indicador del roue Sirena estado del detector Detector en que se 8 parpadeos 8 tonos
52. ocal Bip date heure alarme incendie d tecteur n X 7 2 des anomalies ATTENTION afin de ne pas vous r veiller la signalisation sonore des anomalies d alimentation ou de t te de d tection encrass e survenant la nuit est inhib e L anomalie est alors restitu e soit au retour de la lumi re pendant plus de 10 min soit 12 h apr s l apparition Anomalie d alimentation sur le d tecteur Voyant rouge ATTENTION l apparition de signalisation de voyant Sonnerie noma DE 5 OT Te d alimentation le d tecteur D tecteur al origine 1 clignotement _ 2 bips rapides continue fonctionner de l anomalie toutes les 5 s toutes les 60 s parfaitement pendant Autres iris 30 jours Il est conseill de Rie es 7 i 7 remplacer le bloc lithium d s que possible Si la signalisation sonore du d faut d alimentation appara t un moment inopportun il est possible de la reporter de 8 h sur une dur e maximale de 7 jours en appuyant sur la touche test jusqu au 1 bip Vous disposez ainsi de ce laps de temps pour remplacer le bloc lithium Anomalie d alimentation sur la centrale Apr s une commande syst me la centrale signale vocalement Bip anomalie tension d tecteur n X Anomalie de t te de d tection encrass e ATTENTION l apparition de l anomalie il est recommand de nettoyer le plus rapidement possible la t te de d tection cf Mai
53. rawl out of the house When the alarm rings wake up everyone e Prearrange an assembly point outside the house e Avoid going into the house unnecessarily if there is a fire Call the fire brigade In case of any works in the room Painting the detector is prohibited Protect the detector by covering it fully with the plastic cover supplied Cover the detector with the plastic cover prior to carrying out any work in the room after detector s installation Summary of your detector s responses and indications Normal operation Red signal LED White indicates the state indicator Built in audible alarm of the detector LED the unit flashes once All your detectors every 10 sec Smoke detection 1 Red signal LED White indicates the state indicator Built in audible alarm of the detector LED Detector transmit a built in alarm sounds ting the smoke the IE va lit on a continuous basis detection signal quickly 85 dB A at 3m Other wired a modulated built in inter connected lit audible alarm sounds detectors 85 dB A at 3m 1 The detector response lasts until the smoke has dissipated Detector tests 2 Red signal LED White indicates the state indicator Built in audible alarm of the detector LED the alarms rings Detector the LED flashes for 1 sec 75 dB A transmitting lit the test signal quickly ata3m distance 9 then stops for 1 sec i the alar
54. ri E consigliabile sostituire collegati in rete filare la pila al pi presto Se la segnalazione acustica dell anomalia alimentazione avviene in un momento inopportuno possibile rinviarla di 8 ore per un massimo di 7 giorni premendo il pulsante di test fino al primo bip in questo modo si dispone del tempo per intervenire Anomalia di alimentazione sulla centrale Dopo un comando di acceso o spento la centrale segnala vocalmente bip anomalia tensione rivelatore X Anomalia di testa di rilevazione intasata ATTENZIONE quando si riscontrano anomalie necessario pulire il prima possibile la testa di rilevazione v par Manutenzione Spia rossa Spia FE disegnalazione bianca SUoneria integrata Rivelatore 8 lampeggi _ 8 bip rapidi in anomalia ogni 8 secondi ogni 58 secondi Altri rivelatori collegati in rete filare Se la segnalazione acustica dell anomalia avviene in un momento inopportuno possibile rinviarla di 8 ore per un massimo di 7 giorni premendo il pulsante di test fino al primo bip in questo modo si dispone del tempo per intervenire Anomalia radio sulla centrale Dopo un comando di acceso o spento la centrale segnala vocalmente bip anomalia radio rivelatore X 8 Manutenzione 8 1 Manutenzione della testa di rilevazione La manutenzione regolare del rivelatore ha un importanza essenziale Le s
55. ri rivelatori 3 collegati accesa Lu errs in rete filare 1 Reazioni mantenute fino alla completa dispersione del fumo Test del rivelatore 2 Spia rossa Spia di segnalazione bianca Suonerialintegrata 1 secondo di suoneria Rivelatore lampeggia accesa a75dB A a3m all origine del test rapidamente seguito da 1 secondo di pausa ia A 1 secondo di suoneria paro da lampeggia accesa a 75 dB A a3 m in rete filare rapidamente seguito da 2 secondi di pausa 2 Reazioni dopo la pressione per oltre 10 secondi del pulsante test e fino al rilascio di tale pulsante Segnalazione di anomalia di alimentazione Se la segnalazione acustica Spia rossa di segnalazione Spia bianca Suoneria integrata Rivelatore in anomalia 1 lampeggio ogni 5 secondi 2 bip rapidi ogni 60 secondi Altri rivelatori collegati in rete filare Segnalazione di anomalia di tes ta di rilevazione intasata Spia rossa di segnalazione Spia bianca Suoneria integrata dell anomalia alimentazione o di testa di rilevazione intasata avviene in un momento inopportuno possibile rinviarla di 8 ore per un massimo di 7 giorni premendo il pulsante di test fino al primo bip in questo modo si dispone del tempo per intervenire Rivelatore in anomalia 8 lampeggi ogni 8 secondi 8 bip rapidi ogni 58 secondi Altri rivelatori collegati in rete filare
56. rivelatore troppo A vicino alla centrale anzi raccomandabile codice principale allontanarlo un po portate il rivelatore ad i almeno 2 metri dalla centrale seguito da 990 codice installatore Effettuate la procedura descritta di seguito i bip rivelatore incendio X WD poi i Vo n IX 10 secondi massimo Premete il pulsante e poi sulla tastiera della centrale Tenete premuto il pulsante di programmazione 0 all interno del rivelatore per circa 10 secondi fino a che la centrale non risponde vocalmente E possibile registrare un messaggio di personalizzazione per l identificazione vocale del rivelatore di fumo v Manuale d installazione della centrale par Messaggio d identificazione vocale 4 Installazione del rivelatore Mm ATTENZIONE mantenete una distanza minima di almeno 2 metri tra le apparecchiature 4 1 Scelta del luogo d installazione Il rivelatore deve essere installato e nelle stanze che presentano un rischio d incendio soggiorno con camino stanze per bambini mansarde o scantinati abitati e preferibilmente nel centro del soffitto e lontano da bocchette di ventilazione che potrebbero disperdere il fumo e ad almeno 50 cm di distanza da qualunque ostacolo muro tramezzo trave e alle estremit di un corridoio se la sua lunghezza superiore a 10 m Se il fissaggio in orizzontale a soffitto i
57. rol panel responds You can record a personalised message to identify the fire detector by voice see the Control panel installation manual on Voice identification message 4 Installing the detector CAUTION make sure there is a distance of at least 2 meters between each product except between two detectors 4 1 Choosing the right place The detector must be placed e in rooms where there is a risk of fire living rooms with a fireplace children s bedrooms lofts or basements that are occupied preferably at the center of the ceiling Installation examples e at a distance from ventilation grilles where Smoke smoke might spread detectors more than 50 cm away from obstacles walls partitions beams etc e at either end of corridors more than 10m long If the smoke detector cannot be installed at a horizontal ceiling mount it e more than 50 cm away from the corners of the room Fig 1 e 50 to 60 cm away from the ceiling Fig 1 The detector must not be placed e far away from potential sources of electrical directly on a metal surface interference electricity meter metal e near fluorescent tubes cabinet etc e in very dusty rooms e if it is to be installed on a metal wall inserta in rooms where the temperature could drop shim made of non magnetic material wood below 10 C or rise above 55 C as this or plastic will prevent the detector from operating properly e less than
58. rpadea cada 10 seg DECLARACION DE CONFORMIDAD ED C Fabricante Hager Security SAS 10 Direcci n F 38926 Crolles Cedex France Tipo de producto Detector de humo radio Marca Hager Declaramos bajo nuestra responsabilidad que los productos a los que se refiere esta declaraci n est n conformes con las exigencias esenciales de las directivas siguientes e Directiva R amp TTE 99 5 CE e Directiva Baja Tensi n 2006 95 CE De acuerdo con las siguientes normas europeas armonizadas Ref producto S151 22X EN 300 220 2 V2 1 2 X EN 50130 4 95 A1 98 A2 2002 X EN 60950 2006 X Este producto puede ser utilizado en toda la UE la EEA y Suiza Firma Patrick Bernard Director Investigaci n y Desarrollo Crolles el 21 10 10 C 10 0333 Declaramos en base al certificado de conformidad adjunto que la conformidad del producto denominado anteriormente a sido establecido para responder a las exigencias esenciales de la Directiva DPC 89 106 CE enmendado por la 93 68 CE conforme a la norma EN 14604 2005 y disposiciones del anexo ZA de esta misma norma Certificado de conformidad n m 0333 CPD292 010 Expedido por la Certificaci n AFNOR 11 rue Fran ois de Pressens FR 93571 La plaine St Denis Cedex 2 Firma He Patrick Bernard Director Investigaci n y Desarrollo Y Documento no contractual supeditado a posibles modificaciones sin preaviso ES Tratamiento d
59. rtance The detector head slots are to be vacuum cleaned at least once a year or upon each indication of detector head soiling see section on Fault indication CAUTION if the detector head dirty indication remains after dusting replace the detector We advise you to clean detector using a soft cloth Never use alcohol or acetone to clean it 8 2 Changing the battery If the optional opening of the detector is not locked see Fixing 1 Remove the detector from its base by turning it counter clockwise until you hear a click 2 Replace the worn battery 3 Lock the detector back onto its base see Mounting 4 Make a test see section detector tests If the optional opening of the detector is locked see Fixing 1 Insert a flat blade screwdriver into this notch 2 Remove the detector from its base by turning it counter clockwise until you hear a click 3 Replace the worn battery 4 Lock the detector back onto its base see Mounting 5 Make a test see section detector tests Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type BatLi 26 or BatLi 25 3 6 V Please dispose of the old Lithium battery in a container for this purpose 8 3 In case of any works in the room Painting the detector is prohibited Protect the detector by covering it fully with the plastic cover supplied CAUTION cover the detector with
60. s Fijaci n en una caja de empotrar 1 Para las cajas de empotrar de 60 mm de di metro utilice los agujeros de fijaci n N 60 2 Para las cajas de empotrar de 85 mm de di metro utilice los agujeros de fijaci n N 6 3 Fije la base con los tornillos apropiados Agujeros de fijaci n di metro 60 ATENCI N para permitir el paso de los cables en superficie separe las dos Marca de alineaci n arandelas de fijaci n y col quelas entre el de la tecla test techo y la base del detector en los 2 agujeros de fijaci n Arandelas de fijaci n Agujeros de fijaci n di metro 85 Bloqueo opcional del detector en la base de fijaci n El bloqueo opcional tiene por finalidad impedir el desmontaje no autorizado del detector Con un til corte la pesta a de bloqueo ATENCI N a partir de ahora la apertura del detector s lo podr efectuarse con un destornillador de punta plana ES Haga coincidir las 2 sefiales 4 4 Instalaci n de varios detectores en red indicadoras grabadas en la Es posible interconectar hasta 40 detectores entre s lo que base y en el detector y permite el disparo de la alarma de todos los detectores de bloqu elo haci ndolo girar humo de la habitaci n en el sentido de las agujas As est seguro de ser avisado si el humo se declara en una del reloj estancia alejada de la que usted se encuentra 1 Fijar primero las bases de los detectores ver Fijaci n y luego extraer el ter
61. se unwanted alarm activation to stop alarm in the event of detection of non dangerous smoke In order to disable the detector press the test key until the 1st beep sounds or until the detector stops its built in audible alarm The indicator signalling the state of the detector flashes every 2 sec Red signal LED White indicates the state indicator Built in audible alarm of the detector LED the unit flashes once Sensor shut down every 2 sec Other wired inter connected the unit torta once 7 detectors every 10500 In order not to wake you up alarms resulting from mains supply problems or dirty sensors are shut down during the night Any errors are corrected after daybreak within 10 min i e 12 hours after the event CAUTION For the 15 min disable period the detector will not detect any smoke nor release any audible alarm After the 15 min disable period has passed the detector is automatically reset to normal operation with the detector state indicator flashes every 10 s DECLARATION OF CONFORMITY GBD C Manufacturer Hager Security SAS 10 Address F 38926 Crolles Cedex France Product type Residential radio smoke detector Trade mark Hager We declare under our sole responsibility that the products to which this declaration relates are thus compliant with the essential requirements of the following European Directives e R amp TTE Directive 99 5 CE Low Voltage Directive 2006
62. shager Guide d installation p 2 D tecteur avertisseur de fum e LS radio Manuale di installazione p 20 Rivelatore ottico di fumo via radio Installation guide p 36 Residential radio smoke detector Manual de instalaci n p 52 Detector de humo LS radio S151 22X 4285201007 Sommaire 1 Pr sentation 1 1 Principe de fonctionnement 2 1 2 Descriptif 2 Alimentation 3 3 Apprentissage 4 4 Pose du d tecteur 5 4 1 Choix de l emplacement 5 4 2 Test de la port e radio l endroit choisi 6 4 3 Fixation 4 4 Pose de plusieurs d tecteurs en r seau 8 5 Test du d tecteur 9 6 Inhibition volontaire du d tecteur m concccananconaos 10 7 Signalisation uccconmn 11 7 1 Des d clenchements 11 7 2 Des anomalies als 8 Maintenance 12 8 1 Entretien de la t te de d tection 8 2 Changement de l alimentation 18 8 3 En cas de travaux 13 9 Fiche d utilisation 15 1 Pr sentation 1 1 Principe de fonctionnement Le d tecteur optique de fum e est particuli rement adapt a la d tection d incendies progression lente qui peuvent couver pendant de nombreuses heures avant de s enflammer Il est destin la protection des parties privatives des immeubles ou r sidences d habitations Il peut tre e utilis seul eint gr dans un syst m
63. ssori di fissaggio ed inseriteli tra il soffitto e la base all altezza dei fori di fissaggio utilizzati Spessori di fissaggio Fori di fissaggio diametro 85 mm Bloccaggio del rivelatore alla base facoltativo Il bloccaggio del rivelatore alla base serve ad evitare una rimozione non autorizzata del rivelatore Utilizzando un tronchesino tagliate il dente di bloccaggio ATTENZIONE ora l apertura sar possibile solo utilizzando un cacciavite piatto Allineate le 2 frecce di riferimento presenti sulla base e sul rivelatore poi agganciatelo ruotando in senso orario ATTENZIONE il rilevatore non pu essere fissato alla base se la pila non inserita Non forzate 4 4 Installazione di pi rivelatori in rete E possibile collegare tra di loro un numero massimo di 40 rivelatori in questo modo se uno dei rivelatori collegati in rete rileva fumo anche tutti gli altri rivelatori andranno in allarme 1 Dopo aver fissato le basi dei rivelatori v par Fissaggio sbloccate la morsettiera di collegamento Morsettiera di collegamento 2 Effettuate poi il cablaggio come descritto di seguito Morsetti di o collegamento Non utilizzato a0 Segnale Per un filo di sezione 1 5 mm la lunghezza totale della rete deve essere inferiore a 400 m 3 Richiudete la morsettiera sulla base 4 Fissate il rivelatore sulla base v par Fissaggio ATTENZIONE collegate fra di loro solo rivelatori de
64. sus de 55 C entra nant un mauvais fonctionnement du d tecteur e moins de 1 m des bouches de chauffage de refroidissement ou d a ration la fum e pourrait tre dispers e e moins de 6 m d une chemin e ou d un po le bois o la fum e de combustion risque de provoquer une alarme intempestive e dans un local o les fum es de cuisson et la vapeur d eau risqueraient de provoquer un d clenchement intempestif e dans un local ou il y a risque de condensation ou d humidit proscrire salles de bains buanderies e au sommet d un plafond ogival en forme de A une poche d air a cet endroit risque d emp cher la fum e d atteindre le d tecteur Fig 2 Instructions de pose Fig 1 d gt 50cm Emplacement pr conis 60 cm gt d gt 50 om Emplacement acceptable Fig 2 d gt 50cm 4 2 Test de la port e radio l endroit choisi ATTENTION la centrale doit tre en mode installation afin d effectuer ce test cf Apprentissage 1 Maintenir appuy sur la touche de programmation 0 ou sur la touche test jusqu au d clenchement de la sonnerie int gr e e correct la centrale confirme la bonne liaison radio par un message vocal Bip d tecteur incendie n X e incorrect aucun message vocal rapprocher le d tecteur de fum e de la centrale 2 Repasser la centrale en mode utilisation en composant Le DDA code a 4 3 Fixation
65. tectar e si se realizan actividades en la estancia que puedan generar el humo ni disparar la humo barrido de una habitaci n polvorienta alarma deshollinamiento de una chimenea y provocar un disparo intempestivo de la alarma e para parar la alarma en caso de detecci n de humo no peligroso Para desactivar el detector pulsar la tecla test hasta el primer tono o hasta que la sirena integrada se pare El testigo de indicaci n de estado del detector parpadea cada 2 seg Testigo rojo F indicador del a Sirena estado del detector D tecteur el testigo parpadea _ _ inhib cada 2 seg tros detect j ot dd Les gt el testigo parpadea _ _ alambricamente cada 10 seg Al cabo de esos 15 min el detector retorna automaticamente a su estado operacional y el testigo de estado parpadea cada 10 seg ATENCI N para salir m s r pidamente del modo inhibici n pulsar durante 10 seg aproximadamente la tecla test hasta la activaci n del timbre integrado ver Test del detector 7 Se alizaci n 7 1 de activaciones Durante la desactivaci n la central restituir dicha activaci n por el mensaje de voz Bip fecha hora alarma incendio detector n 7 2 de anomal as ATENCI N para no despertarle la se al ac stica de las anomal as de alimentaci n o de cabecera de detecci n registradas durante la noche es inhibida La anomal a es entonces restituida o bien al volver la
66. umo de combusti n puede provocar el disparo intempestivo de la alarma e en locales donde el humo de cocci n y el vapor de agua puedan provocar el disparo intempestivo de la alarma e en locales donde haya riesgo de condensaci n o de humedad evitar los cuartos de ba o lavander as etc e en la cima de un techo abovedado en forma de A ya que el aire que se concentra en este sitio puede impedir que el humo llegue el detector Fig 2 Ejemplos de fijaci n Fig 1 d gt 50 cm Ubicaci n recomendada 60 cm gt d gt 50 om Ubicaci n aceptable Fig 2 d gt 50 cm 4 2 Test de cobertura de radio en el lugar elegido ATENCI N la central debe estar en modo instalaci n para efectuar este test ver Aprendizaje 1 Mantener la pulsaci n sobre la tecla de programaci n 0 u la tecla test hasta que la sirena integrada se dispare e correcto confirmaci n de la central por mensaje vocal del enlace bip detector incendio n X e incorrecto ning n mensaje de voz Reajustar el detector de humos a la central 2 Reconfigurar la central en modo utilizaci n Para ello pulsar SEE A D DA instalador 4 3 Fijaci n Fijaci n est ndar 1 Coloque la base en el sitio elegido y marque con un l piz el centro de los 2 agujeros de fijaci n N o 63 2 Practique los agujeros con una broca de 5 mm de di metro 3 Fije la base con los tacos y los tornillos apropiado
67. wer supply failure occurs at an inappropriate time it is possible to postpone its occurrence for an 8 hour delay over a maximum 7 day period by pressing the test key until the 1st beep is released This is the time period available for replacing the Lithium battery Power supply fault on the control panel Following a system command the control panel issues the following voice message beep fault battery detector X Indication of detection head clogging CAUTION when this problem arises the detection head should be cleaned as quickly as possible see Maintenance Red signal LED White indicates the state indicator Built in audible alarm of the detector LED Detector at the source the unit flashes 8 times the unit releases of the fault indication over an 8 sec period 8 fast beeps every 58 sec Other wired inter connected detectors If the sound indication of the soiled detector head state is released at an inappropriate time it is possible to postpone its occurrence for an 8 hour delay over a maximum 7 day period by pressing the test key until the 1st beep is released This is the time period available for cleaning the detector Radio fault on the control panel Following a system command the control panel issues the following voice message beep fault radio detector X 8 1 Detector head maintenance The regular maintenance of the detector is of utmost impo
68. y SAS 10 Indirizzo F 38926 Crolles Cedex France Tipo di prodotto Rivelatore ottico di fumo via radio Modello depositato Hager Dichiariamo sotto la nostra responsabilit che il prodotto al quale questa dichiarazione fa riferimento conforme ai requisiti essenziali delle seguenti direttive e Direttiva R amp TTE 99 5 CE e Direttiva Bassa Tensione 2006 95 CE in ottemperanza alle seguenti Normative Europee armonizzate Codice dei prodotti S151 22X EN 300 220 2 V2 1 2 X EN 50130 4 95 A1 98 A2 2002 X EN 60950 2006 X Questo prodotto pu essere utilizzato in tutta l UE i paesi di EEA Svizzera Crolles le 21 10 10 Firmato Patrick Bernard ioe Direttore Ricerca e Sviluppo CE B 0333 Dichiariamo sulla base dell allegata Dichiarazione di Conformit ad esso relativo che la conformit del prodotto sopra detto stata definita per rispondere ai requisiti essenziali della Direttiva DPC 89 106 CE modificata dalla 93 68 CE conformemente alla Norma EN14604 2005 e disposizioni dell allegato ZA di questa stessa norma Certificato di conformit n 0333 CPD292 004 Rilasciato da AFNOR Certification 11 rue Frangois de Pressens FR 93571 La plaine St Denis Cedex Firmato aa Patrick Bernard Direttore Ricerca e Sviluppo Documento non contrattuale pu essere soggetto a modifiche senza preavviso Trattamento delle E apparecchiature elettriche ed elet troni