1. hacer que la bomba se recaliente e invalidar la garant a Rendimiento 7 La bomba viene con lubricaci n permanente No se necesita aceitar ni engrasar durante una operaci n normal Para ponerla L M a altura total en metros aaa eds a punto consulte las incrustaciones en la secci n de Servicio Modelo 3 6 9 12 aus so de Li indican a que aparece en la p gina 5 Capacidad litros minuto continuaci n HTS50A1 246 227 189 114 14 6 Los flujos son para agua con una temperatura de 200 F 93 3 C Especificaciones Requiere Carga un ramal Tama o del Graduaci n del Modelo Motor max individual adaptador de conmutador en pulgadas mm No CV Voltios Fase amperios amperios descarga pulgadas Activado Desactivado HTS50A1 1 2 115 1 12 0 15 2 17 8 452 8 8 224 293 WRIGHT STREET DELAVAN WI 53115 WWW HYDROMATIC COM PH 888 957 8677 2013 Pentair Ltd All Rights Reserved HYD505 Rev 03 04 13 Instalaci n ADVERTENCIA Riesgo de choque el ctrico Puede causar quemaduras o muerte No levante la bomba por medio del cord n de corriente Consulte el cuadro de Advertencia sobre la utilizaci n del cord n para levantar AVISO Instale la bomba sobre una superficie dura nivelada cemen to asfalto etc Nunca coloque la bomba directamente sobre super ficies de tierra arcilla o arenilla La esclusa debe ser por lo menos de 18 457 mm de di metro y 30
2. Litres par minute la hauteur totale en metres Aucun d bit la hauteur Mod le 3 AA 9 12 ingiqu e D bits litres minute ci dessous HTS50A1 246 227 189 114 14 6 m Les d bits indiqu s sont pour une temp rature de 93 3 C 200 F Caract ristiques Diam trede Puissance Charge Circuit s par en pouces R glages du pressostat Num ro en cheval Tension maximale requis de l adaptateur en pouces en mm de modele de moteur en volts Phase en amp res amp res de refoulement Marche Arr t HTS50A1 1 2 115 1 12 0 15 2 17 8 452 8 8 224 293 WRIGHT STREET DELAVAN WI 53115 WWW HYDROMATIC COM PH 888 957 8677 O 2013 Pentair Ltd All Rights Reserved HYD505 R v 04 03 13 Instalaci n AVERTISSEMENT Risque de secousses lectriques pouvant causer des br lures voire la mort Ne pas lever la pompe par son cordon lectrique Se reporter Avertissement concernant le levage par le cordon lectrique REMARQUE Installer la pompe sur une surface dure et de niveau ciment asphalte etc Ne jamais la faire reposer directement sur une surface en terre en glaise ou en gravier Le diam tre du puisard doit tre d au moins 457 mm 18 pouces et sa profondeur d au 762 mm 30 pouces Tuyauterie Le diam tre de la tuyauterie ne doit pas tre plus petit que celui du refoulement de la pompe Si cette pompe est install
3. Pieces de rechange HTS50A1 Anneau de levage U97 102SS EE Bouchon du T filtre huile U78 57DV Moteur se reporter au tableau Carter du moteur PW18 54E Vis d assemblage t te hexagonale de 1 4 4 U30 883SS Xx Plaque d tanch it PW18 53A Volute se reporter au tableau Joint d arbre t te fixe U9 439A Joint d arbre bague d appui rotative U9 439B Cordon lectrique 27633B000 Vis d assemblage U30 539SS Collier de serrage du cordon de l interrupteur a flotteur CC0030 13 Interrupteur a flotteur PW217 25A Vis a t te creuse yr i pans de 1 4 20 4 00000 Contre crou six pans de 7 16 20 U36 33SS Pas illustr e Impulseur se reporter au tableau Huile di lectrique 3 ptes requises U197 8A NOTA 2 6 ptes sont utilis es dans tous les mod les U30 475SS Joint torique U9 365 Bossages taraud s 1 2 po NPT 10 Recherche des pannes moment l on intervient sur la pompe on risque de subir une AVERTISSEMENT D marrages inopin s Si le courant parvient secousse lectrique ou bien de se faire coincer les doigts par la pompe lorsque le protecteur contre les surcharges se r en Pimpulseur ou les outils Avant d intervenir sur la pompe couper le clenche la pompe peut d marrer sans avertissement Si ce courant qui l alimente INCIDE
4. 26 22 18 14 10 w Longueurs du cordon pouces 5 6 10 14 18 22 26 30 34 38 5 5 Gammes de pompage pouces Graphique des rendements Longueurs du cordon par rapport aux gammes de pompage Entretien La pompe est lubrifi e en permanence En utilisation normale il n est pas n cessaire de la huiler ni de la graisser REMARQUE Ne pas laisser fonctionner la pompe sec sinon la garantie sera annul e et la pompe sera endommag e AVERTISSEMENT Tension dangereuse pouvant causer des secousses lectriques des br lures voire la mort Avant d intervenir sur la pompe couper le courant qui alimente la pompe et l interrupteur de commande Apr s avoir enlev le couvercle du puisard et d brancher la tuyauterie de refoulement n cessaire sortir la pompe du puisard AVERTISSEMENT Risque de secousses lectriques pouvant causer des br lures voire la mort Ne pas lever la pompe par son cordon lectrique Se reporter Avertissement concernant le levage par le cordon lectrique Mettre la pompe dans un endroit o elle pourra tre compl tement nettoy e Enlever tout le tartre et tous les d p ts de la pompe Immerger la pompe dans un d sinfectant chlore pendant au moins une heure avant de la d monter Le carter du moteur de la pompe contient une huile lubrifiante s
5. HYDROMATIC les produits qui se r v leraient d fectueux L Acheteur s engage payer tous les frais de main d uvre et d exp dition du produit couvert par sa garantie et de s adresser au concessionnaire installateur ayant proc d l installation d s qu un probl me est d couvert pour obtenir un service sous garantie Aucune demande de service en vertu de sa garantie ne sera accept e apr s expiration de la dur e de sa garantie Ces garanties ne sont pas transf rables EXCEPTIONS Les pompes pour applications sp ciales les pompes de puisard de secours batterie les pompes d effluents filtre les pompes broyeuses et les pompes d eaux d gout de 2 1 2 po Hydromatic sont garanties pendant une p riode de 12 mois suivant la date d achat ou une p riode de 18 mois suivant la date de fabrication selon la premi re occurrence HYDROMATIC D CLINE TOUTE RESPONSABILIT POUR TOUT DOMMAGE INDIRECT O FORTUIT QUEL QU IL SOIT LA GARANTIE LIMIT E SUSMENTIONN E EST EXCLUSIVE ET REMPLACE TOUTES LES AUTRES GARANTIES EXPRESSES ET TACITES Y COMPRIS MAIS SANS S Y LIMITER LES GARANTIES DE QUALIT MARCHANDE ET D ADAPTATION UN USAGE PARTICULIER LA GARANTIE LIMIT E SUSMENTIONN E NE DOIT PAS TRE PROLONG E AU DEL DE LA DUR E PR VUE AUX PR SENTES Certains tats territoires et certaines provinces ne permettent pas l exclusion ou la limitation des dommages indirects ou fortuits ni les limitations relatives la dur e de
6. ODO DE DURACI N INDICADO EN LA PRESENTE Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes o de limitaciones de tiempo sobre garant as impl citas de modo que es posible que las limitaciones o exclusiones que preceden no correspondan en su caso Esta garant a le otorga derechos legales espec ficos y es posible que usted tambi n tenga otros derechos que pueden variar de un estado al otro Esta Garant a Limitada entra en vigor el 1 de junio de 2011 y sustituye toda garant a sin fecha o garant a con fecha anterior al 1 de junio de 2011 HYDROMATIC 293 Wright Street Delavan WI 53115 Tel fono 888 957 8677 Fax 800 426 9446 Sitio web hydromatic com 18 This page intentionally left blank
7. 10 14 18 22 26 30 34 38 5 5 Pumping Range Inches 413 0893 Performance Graph Tether Length vs Pumping Range Pump is permanently lubricated No oiling or greasing is required in normal service NOTICE Do not allow pump to run in a dry sump It will void the warranty and may damage the pump A WARNING Hazardous voltage Can shock burn or cause death Before servicing pump disconnect electrical power to pump and control switch After removing basin cover and necessary discharge piping lift pump out of basin A WARNING Risk of electrical shock Can burn or kill Do not lift pump by power cord See Cord Lift Warning Place the pump in an area where it can be cleaned thoroughly Remove all scale and deposits on the pump Submerge the complete pump in a disinfectant solution dilute chlorine bleach for at least one hour before disassembling the pump The pump motor housing contains a special lubricating oil Keep oil clean and free of water at all times NOTICE Whenever motor cover is being removed for service remove oil and replace with new oil at reassembly Use only oil listed in parts list Part No U197 8A When filling with new oil DO NOT overfill To allow room for expansion oil level with cold motor should be about 1 4 6 mm above top of motor assembly Impeller and Seal Replacement A WARNING Risk of electrical shock Disconnect electrical power before
8. ADVERTENCIA Arranques repentinos Si la corriente a la el ctricos o de que el impulsor atrape sus dedos o sus herra bomba est activada cuando se reposicione la sobrecarga t r mientas Desconecte la corriente antes de realizar reparaciones en mica es posible que la bomba arranque sin advertencia alguna la bomba A La bomba no funciona Verifique que el cord n de corriente est bien enchufado en la toma de corriente o cableado en forma segura al controlador o a la caja de conmutaci n Desconecte la corriente hacia la toma de corriente antes de manipular la bomba o el motor 2 Verifique que haya corriente el ctrica 3 Verifique que el nivel del fluido l quido sea suficiente para activar el conmutador o el controlador 4 Verifique que haya un orificio de ventilaci n de 3 16 5 mm en la tuber a de descarga y que no est tapado 5 Verifique que no hayan bloqueos en la admisi n de la bomba en el impulsor en la v lvula de retenci n o en la tuber a de descarga 6 Es posible que la sobrecarga t rmica se haya disparado Haga una prueba para arrancar la bomba Si arranca y luego se detiene inmediatamente descon ctela de la fuente de energ a por 30 minutos para permitir que el motor se enfr e y luego vuelva a conectarla a la fuente de corriente Verifique la causa del recalentamiento la sobrecarga 7 Si la bomba no funciona de ninguna manera o contin a funcionando mal consulte a su t cnico de reparaciones
9. de corriente o a los disyuntores antes de realizar reparaciones 8C Para reducir el riesgo de choques el ctricos tenga cuidado cuando cambie los fusibles o reposicione los disyuntores No se pare en el agua cuando trabaje con la caja de control o con los disyuntores Advertencia de la Proposici n 65 de California A ADVERTENCIA Este producto y accesorios relaciona dos contienen sustancias qu micas reconocidas en el Estado de California como causantes de c ncer malformaciones cong nitas y otros da os al sistema reproductivo Bombas monof sicas 8D Cuando use un cord n y enchufe solamente enchufe la bomba a una toma de corriente con conexi n a tierra Cuando haga el cableado a un dispositivo de control de sistemas conecte el conector a tierra de la bomba a la puesta a tierra del sistema Descripci n Estas bombas han sido dise adas para la remoci n de aguas eflu ente y aguas residuales para drenar sumideros para sistemas de transferencia de l quidos circulaci n achique escurrimiento y con trol de inundaciones Los motores de la bomba son monof sicos de 115 voltios Viene con un cord n de 20 pies de largo y un enchufe de 3 clavijas con conexi n a tierra La temperatura m xima del l quido para el modelo HTS50 es de 200 F 93 3 C AVISO Esta unidad no ha sido dise ada para uso con agua salada o salubre El uso con agua salada o salubre anular la garant a
10. e sur un r seau d eaux r siduaires le diam tre des tuyaux doit laisser passer des mati res semi solides ayant au moins 19 mm 3 4 de pouce Le d bit dans le tuyau de refoulement doit garder toutes les mati res solides pr sentes en suspension dans le liquide Pour satisfaire les conditions du d bit minimal qui est de 61 cm s 2 pi s le diam tre du tuyau de refoulement doit correspondre aux suivants Permettre un d bit de Un tuyau d un diam tre de 51 mm 2 pouces 64 mm 2 1 2 pouces 76 mm 3 pouces 79 5 I m 21 gal min 113 5 I m 30 gal min 182 l m 48 gal min Dans le cas d un r seau d eaux r siduaires poser un clapet antiretour d au moins 38 mm 1 1 2 pouce sur le tuyau de refoulement pour emp cher le liquide de retourner dans le puisard Le battant du clapet doit tre a d bit libre pour permettre aux mati res solides de le traverser facilement S assurer que l installation du clapet antiretour est conforme tous les codes de la municipalit REMARQUE Pour obtenir le meilleur fonctionnement possible du clapet antiretour lors du pompage de mati res solides ne pas l installer en orientant vers le haut son refoulement plus de 45 par rapport l horizontale Ne pas l installer la verticale sinon les mati res solides se d poseront sur son battant et l emp cheront de s ouvrir au d marrage de la pompe Percer un trou de 5 mm 3 16 de pouce dans le tuyau d
11. et les instructions 2 Avant de proc der l installation se reporter aux codes de la municipalit et s y conformer 3 A rer l gout ou la fosse septique conform ment ces codes 4 Ne pas installer cette pompe dans un lieu comme tant class dangereux par le Code canadien de l lectricit le National Electric Code ANSI NFPA 70 1984 5 Pour ne pas se br ler si on doit intervenir sur la pompe la laisser refroidir pendant 20 minutes apr s qu elle s est arr t e et avant de la manipuler 6 Ne pas faire fonctionner la pompe sec sinon elle surchauffera et la garantie sera annul e 7 La pompe est lubrifi e en permanence En utilisation normale il rest pas n cessaire de la huiler ni de la graisser Pour la r viser se reporter Instructions sous Entretien page 3 NOTICE D INSTALATION DE FONCTIONNEMENT ET DES PI CES Serie HTS50 Pompes en fonte pour eaux r siduaires AVERTISSEMENT Tension dangereuse pouvant causer des secousses lectriques des br lures voire la mort Pendant qu elle fonctionne la pompe est immerg e dans l eau Si on doit intervenir sur la pompe et pour ne pas tre lectrocut proc der comme suit 8A Mettre la pompe la terre conform ment tous les codes et d crets en vigueur 8B Avant d intervenir sur la pompe couper le courant qui alimente sa prise de courant ou fermer les disjoncteurs 8C Pour r duire les risques de secousse
12. gt PENTAIR HYDROMATIC SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump This is the safety alert symbol When you see this symbol on your pump or in this manual look for one of the following signal words and be alert to the potential for personal injury CEE warns about hazards that will cause serious personal injury death or major property damage if ignored WARNING warns about hazards that can cause serious personal injury death or major property damage if ignored A CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored The word NOTICE indicates special instructions which are important but not related to hazards NOTICE Pump must be installed in a vertical position only Installing pump in any other position will void warranty 1 To avoid serious injury and or property damage read these rules and instructions carefully 2 Check your local codes before installing You must comply with their rules 3 Vent sewage or septic tank according to local codes 4 Do not install pump in any location classified as hazardous by National Electrical Code ANSI NFPA 70 1984 5 Pump normally runs hot To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling it 6 Do not run pump dry Dry running can overheat pump and will void warranty 7 Pump is permanently lubri
13. state This Limited Warranty is effective June 1 2011 and replaces all undated warranties and warranties dated before June 1 2011 HYDROMATIC 293 Wright Street Delavan WI 53115 Phone 888 957 8677 Fax 800 426 9446 Web Site hydromatic com gt PENTAIR HYDROMATIC Consignes de s curit Lire attentivement et observer toutes les consignes de s curit figurant dans cette Notice ou sur la pompe Ce symbole indique qu il faut tre prudent Lorsque ce symbole appara t sur la pompe ou dans cette Notice rechercher une des mises en garde qui suivent car elles indiquent un potentiel possible de blessures corporelles OA avertit d un danger qui causera des blessures corporelles la mort ou des dommages mat riels importants si on Pignore AVERTISSEMENT avertit d un danger qui risque de causer des blessures corporelles la mort ou des dommages mat riels importants si on l ignore ATTENTION avertit d un danger qui causera ou qui risquera de causer des blessures corporelles la mort ou des dommages mat riels importants si on l ignore Le mot REMARQUE indique des instructions sp ciales et importantes n ayant aucun rapport avec les dangers REMARQUE La pompe doit tre install e la verticale seulement L installer dans toute autre position annulera la garantie 1 Pour viter toutes blessures et ou causer des dommages mat riels graves lire attentivement les consignes de s curit
14. trip overload relays of the recommended size or the warranty is void Your only remedy and HYDROMATIC s only duty is that HYDROMATIC repair or replace defective products at HYDROMATIC s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty so the above limitations or exclusions may not apply to You This warranty gives You specific legal rights and You may also have other rights which vary from state to
15. 762 mm de profundidad Tuber a La tuber a no debe ser m s peque a que la descarga de la bomba Cuando se instale en un sistema de efluente la tuber a deber ser capaz de manipular part culas semi s lidas de un m nimo de 3 4 19 mm de di metro La velocidad de gasto en la tuber a de descarga deber mantener toda part cula s lida presente en suspensi n dentro del l quido Para cumplir con el m nimo de requisitos de flujo de 2 pies por segundo 61 cm segundo en la l nea de descarga las tuber as deber n ser de los tama os siguientes Una tuber a de Manipular una velocidad de gasto 2 51 mm 21 GPM 79 5 L M 2 1 2 64 mm 30 GPM 113 5 L M 3 76 mm 48 GPM 182 L M En un sistema de efluente use una v lvula de retenci n de 1 1 2 38 mm en la descarga de la bomba para evitar retroflujo de l qui do a la esclusa del sumidero La v lvula de retenci n deber ser una v lvula de flujo libre que pueda pasar part culas s lidas con facilidad Aseg rese de que la instalaci n de la v lvula de retenci n cumpla con los c digos locales AVISO Para un mejor rendimiento de la v lvula de retenci n en el manejo de part culas s lidas no la instale con la descarga en un ngulo mayor de 45 sobre el nivel horizontal No instale la v lvula de retenci n en una posici n vertical ya que eso puede hacer que las part culas s lidas se asienten en la v lvula y eviten que se abr
16. NTS Rem des La pompe ne fonctionne pas 1 S assurer que le cordon lectrique est fermement branch dans la prise de courant ou ad quatement branch sur le contr leur ou la bo te de l interrupteur Avant de manipuler la pompe ou le moteur couper le courant qui alimente la prise de courant 2 S assurer que le courant lectrique parvient la pompe 3 S assurer que le niveau du liquide est suffisamment haut pour actionner l interrupteur ou le contr leur 4 S assurer que le trou de mise a Pair libre de 5 mm 3 16 de pouce perc dans le tuyau de refoulement n est pas bouch 5 S assurer que l admission de la pompe l impulseur le clapet antiretour ou le tuyau de refoulement ne sont pas bouch s 6 Le protecteur contre les surcharges thermiques s est peut tre d clench Contr ler le d marrage de la pompe Si elle d marre et s arr te imm diatement la d brancher pendant 30 minutes pour laisser son moteur refroidir puis la rebrancher D terminer la cause de la surchauffe surcharge 7 Si la pompe ne fonctionne pas du tout ou qu elle continue de mal fonctionner s adresser un r parateur local La pompe ne vide pas le puisard 1 S assurer que les robinets du tuyau de refoulement sont compl tement ouverts 2 Nettoyer le tuyau de refoulement et le clapet antiretour 3 S assurer que l admission de la pompe et ou l impulseur ne sont pas bouch s 4 La pompe n est pas assez puissante Une de plus
17. Of 2 51 mm 21 GPM 79 5 L M 2 1 2 64 mm 30 GPM 113 5 L M 3 76 mm 48 GPM 182 L M In an effluent system use a 1 1 2 38 mm min check valve in pump discharge to prevent backflow of liquid into pump basin The check valve should be a free flow valve that will easily pass solids Be sure check valve installation complies with local codes NOTICE For best performance of check valve when handling solids do not install it with discharge more than 45 above the horizontal Do not install check valve in a vertical position as solids may settle in valve and prevent opening on startup Drill a 3 16 5 mm hole in discharge pipe about 1 to 2 25 50 mm above pump discharge connection but below check valve to prevent airlocking the pump Electrical WARNING Hazardous voltage Can shock burn or cause death When installing operating or servicing this pump follow safety instructions below 1 DO NOT splice the power cord submerge electrical cord plug or use extension cords 2 DO NOT handle or service pump while it is connected to power supply 3 DO NOT operate pump unless it is properly grounded Power cord is a 3 wire conductor with 3 prong grounding type plug Do not modify cord or plug Plug pump into a 3 wire grounded grounding type receptacle only Connect pump according to all applicable codes For automatic operation plug or wire pump into the automatic float switch For continuou
18. a durante el arranque Perfore un orificio de 3 16 5 mm en la tuber a de descarga a unos 1 2 25 50 mm por encima de la conexi n de descarga de la bomba pero debajo de v lvula de retenci n para evitar la creaci n de bolsas de aire en la bomba Sistema el ctrico A ADVERTENCIA Tension peligrosa Puede causar choque quemaduras o muerte Cuando instale opere o repare esta bomba observe las instrucciones de seguridad indicadas a continuaci n 1 NO empalme el cord n de corriente el ctrica no sumerja el cord n el ctrico ni el enchufe ni use cordones de alargue 2 NO manipulee ni repare la bomba mientras est conectada al suministro de energ a 3 NO opere la bomba a menos que est debidamente conectada a tierra El cord n es un conductor trifilar con un enchufe de tres puntas con puesta a tierra No modifique el cord n ni el enchufe Solamente enchufe la bomba en una toma de corriente trifilar conexi n a tierra debidamente puesta a tierra Conecte la bomba conforme a todos los c digos correspondientes Para una operaci n autom tica enchufe o cablee la bomba en el conmutador autom tico de flotador Para una operaci n continua enchufe directamente en una toma de corriente o haga el cableado directo a la caja de conmutaci n Conecte la bomba a su propio requiere un ramal individual sin ning n otro dispositivo en ese cir cuito Consulte la tabla de especificaciones p gina 3 para verificar los tama
19. abeza hueca que sostienen la cubierta del motor a la placa de estancamiento y saque la cubierta del motor 7 Saque la mitad giratoria de la junta de estancamiento del eje 8 Coloque la unidad del motor de manera que quede en posici n vertical con el eje del motor saliendo fuera del fondo 9 Saque los pernos pasantes de la unidad del motor Saque el motor y el eje de la placa de estancamiento Trabajando desde la parte posterior de la placa de estancamiento golpetee la cabeza de la junta primaria para sacarla de la placa de estancamiento limpie bien la cavidad de asentamiento Re ensamblaje AVISO Aseg rese de que las superficies de la junta de estancamiento est n limpias y sin aver as Aplique Permatex 2 o un producto equivalente con moderaci n en el borde exterior del cuerpo de la junta con el resorte Figura 1 1 Presione el nuevo cuerpo de la junta en la cavidad de la placa de estancamiento Figura 1 PON 10 Lado del impulsor de la placa de estancamiento Permatex cza kag Presionar la z a f aqu iy Ser junta en la cavidad Figura 1 2 Vuelva a instalar el motor y el eje en la placa de estancamiento usando los cuatro pernos pasantes que se retiraron en el paso 10 de la secci n de Desensamblaje AVISO No apriete demasiado los pernos pasantes 3 Deslice la nueva mitad giratoria de la junta en el eje Figura 2 AVISO No haga muescas ni raye la superficie de la junta de
20. alabra AVISO indica instrucciones especiales que son impor tantes pero que no est n relacionadas con los peligros AVISO La bomba debe instalarse en posici n vertical solamente La instalaci n de la bomba en cualquier otra posici n invalidar la garant a 1 Es importante que lea cuidadosamente estas reglas e instruc ciones para evitar lesiones graves y o da os materiales 2 Verifique sus c digos locales antes de la instalaci n Deber cumplir con sus reglas 3 Ventile el tanque cloacal o s ptico seg n los c digos locales 4 No instale la bomba en ning n lugar clasificado como peligroso por el C digo El ctrico Nacional ANSI NFPA 70 1984 5 La bomba est caliente al tacto durante la operaci n Para evitar quemaduras durante las operaciones de reparaci n y mantenimiento deje que se enfr e durante 20 minutos despu s de haberla apagado y antes de manipularla 6 No haga marchar la bomba en seco La marcha en seco puede MANUAL DE INSTALACI N OPERACI N Y REPUESTOS Series HTS50 Bomba sumergible para efluente de alta temperatura ADVERTENCIA Tensi n peligrosa Puede causar cho que quemaduras o muerte La bomba se encuentra en agua durante la operaci n Para evitar choques fatales contin e de la siguiente manera si la bomba necesita reparaciones 8A Conecte la bomba a tierra conforme a todos los c digos y reglamentos correspondientes 8B Desconecte la corriente a la caja de toma
21. carburo de silicio cuando la pase por encima del hombro del eje Las superficies de la junta de estancamiento debe estar lim pias y sin aver as o pueden haber fugas Deslizar la parte de cer mica en el eje N Figura 2 4 Vuelva a armar el impulsor la arandela y la tuerca del impulsor 5 Inspeccione cuidadosamente el aro t rico c mbielo si est averiado Si no tiene muescas ni ara azos limpielo y vuelva a instalarlo AVISO Se recomienda cambiar el aro t rico cada vez que se realicen reparaciones en la bomba 6 Vuelva a conectar los cables del motor al conector Rem tase a las marcas codificadas a color 7 Rellene el motor con aceite diel ctrico limpio Repuesto No U197 8A Para permitir espacio para expansiones el nivel del aceite con el motor fr o debe ser 1 4 6 mm m s o menos por encima de la parte superior de la unidad del motor Conexiones de los cables verde blanco rojo negro verde a blanco rojo negro conductores del motor ADVERTENCIA A x 0 Riesgo de choque el ctrico Puede quemar o matar No levante la bomba por medio del cord n de corriente Advertencia sobre la utilizaci n del cord n para levantar 1 Si se trata de levantar o sostener la bomba por medio del cord n de corriente se puede da ar el cord n y sus conexiones 2 El cord n se puede dividir dejando expuestos los hilos desnudos y la posibilidad
22. cated No oiling or greasing is required in normal operation For overhaul see instructions under Service Page 5 INSTALLATION OPERATION amp PARTS MANUAL HTS50 Series Submersible High Temperature Effluent Pump A WARNING Hazardous voltage Can shock burn or cause death During operation the pump is in water To avoid fatal shocks proceed as follows if pump needs servicing 8A Ground pump according to all applicable codes and ordinances 8B Disconnect power to outlet box or circuit breakers before servicing 8C To reduce risk of electric shock take care when changing fuses or resetting circuit breakers Do not stand in water when working on control box or with circuit breakers Single Phase Pumps 8D When using cord and plug plug into a grounded outlet only When wiring to a system control connect pump ground lead to system ground California Proposition 65 Warning AWARNING This product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm DESCRIPTION These pumps are designed for effluent and waste water removal sump drainage liquid transfer systems circulation dewatering and flood control Pump motors are 115V single phase Comes with a 20 3 prong grounding type cord and plug The maximum liquid temperature for HTS50 is 200 F 93 3 C NOTICE This unit is not designed for applications involving salt wate
23. d Assembly U97 102SS PW217 282 Y Capscrew U30 539SS Oil Fill Plug a U78 57DV Float Switch Motor Assembly Cord Clamp CC0030 13 See Chart Motor Cover PW18 54D l 1 4 Hex Capscrew 4 U30 883SS Float Switch PW217 25A Capscrew 1 4 20 x 1 Soc Hd Screw 4 Seal Plate z U30 475SS PW18 53A A f O Ring Volute U9 365 See Chart on Shaft Seal Stationary Bosses tapped Head Assembly 7 16 Hex Nut 1 2 NPT U9 439A U36 33SS Shaft Seal Rotating Mating Ring Not Shown U9 439B Dielectric Oil Qt 3 Required U197 8A Impeller NOTE Pump uses 2 6 Qts See Chart TROUBLESHOOTING WARNING Sudden Starts If power is on to pump when thermal overload resets pump may start without warning If you are working on pump you may get an electrical shock or impeller may catch fingers or tools Disconnect power before servicing pump A Pump fails to operate 1 Check to be sure that power cord is securely plugged into outlet or securely wired into controller or switch box Disconnect power to outlet before handling pump or motor Check to be sure you have electrical power Check that liquid fluid level is high enough to activate switch or controller Check to be sure that 5 mm 3 16 vent hole in discharge pipe is not plugged Check for blockage in pump inlet impeller check valve or discharge pipe Therma
24. de incendi os o choques el ctricos 3 Si la bomba se levanta o se sostiene por medio del cord n de corriente la garant a quedar inv lida 4 Use el aro o mango de sujeci n en la parte superior de la bomba para levantarla o bajar la Desconecte la corriente a la bomba antes de realizar trabajos en la bomba o de tratar de sacarla del sumidero Piezas de repuesto HTS50A1 Mango anular de cuerda Unidad del cord n el ctrico U97 10258 PW217 282 Se gt Tornillo U30 539SS Tap n de relleno E de aceite U78 57DV Unidad del motor Abrazadera del cord n del interruptor de flotador ver gr fico a j CC0030 13 DY Cubierta BA 4 del motor PW18 54D Tornillo prisionero O D o D hexagonal 4 de 1 4 U30 883SS Interruptor de flotador PW217 25A Tornillo prisionero de cabeza hueca Plancha de estancamiento 4 de 1 4 20 PW18 53A ___ Sn A U30 475SS Aro t rico Voluta U9 365 ver grafico Sello del eje unidad de cabeza fija U9 439A Sello del eje aro giratorio de acoplamiento U9 439B Copas de rosca Contratuerca hexagonal de 1 2 NPT de 7 16 20 U36 33SS No ilustrado Aceite diel ctrico Qt requiere 3 U197 8A Impulsor NOTA Todos los modelos usan 2 6 qts ver gr fico 16 Localizaci n de fallas Si est trabajando en la bomba existe el peligro de choques A
25. doing any service work on pump Refer to assembly drawing Disassembly 1 Unscrew hex head cap screws remove motor assembly from volute and set it on its side in a clean area Remove oil plug Turn pump upside down to drain oil Hold impeller remove impeller nut and washer Unscrew impeller turn counter clockwise for cleaning Loosen cord nut and gently pull cord assembly out from motor cover Disconnect wires from cord set wires and connector are color coded for reassembly 6 Unfasten socket head screws holding motor cover to seal plate and remove motor cover 7 Remove rotating half of seal off of shaft 8 Cradle motor assembly so that it stands vertically with motor shaft extending out of the bottom 9 Remove through bolts from motor assembly Remove motor and shaft from seal plate 10 Working from back of seal plate tap primary seal head out of seal plate thoroughly clean seat cavity Re assembly NOTICE Make sure that seal faces are clean and undamaged Apply Permatex 2 or equivalent sparingly to outside edge of seal body with spring Figure 1 1 Press new seal body into cavity in seal plate Figure 1 ae ON 2 Reinstall motor and shaft to seal plate using the four through bolts removed in step 10 under Disassembly NOTICE Do not overtighten through bolts 3 Slide new rotating half of seal onto shaft Figure 2 NOTICE Do not nick or scratch the silicon carbide seal face when passing
26. e refoulement entre 25 et 50 mm 1 et 2 pouces au dessus du branchement du refoulement sur la pompe mais sous le clapet antiretour pour emp cher la formation de bouchons d air dans la pompe lectricit AVERTISSEMENT Tension dangereuse pouvant causer des secousses lectriques des br lures voire la mort Pour installer faire fonctionner ou intervenir sur cette pompe observer les consignes de s curit qui suivent 1 NE PAS pisser ni immerger sa fiche et ne pas utiliser de cordon prolongateur 2 NE PAS intervenir sur la pompe ni la manipuler pendant qu elle est branch e sur le courant lectrique 3 NE PAS la faire fonctionner si elle n est pas ad quatement mise la terre Les pompes sont livr es avec un cordon lectrique fiche 3 broches et 3 conducteurs dont un de mise la terre Ne pas modifier le cordon ni la fiche Ne brancher la pompe que dans une prise de courant 3 trous ad quatement mise la terre La brancher conform ment tous les codes en vigueur Pour le fonctionnement en automatique brancher ou c bler la pompe dans un interrupteur flotteur automatique ou un contr leur Pour le fonctionnement continu brancher la pompe directement dans la prise de courant ou bien la c bler directement dans la bo te de l interrupteur Brancher la pompe sur un circuit s par sur lequel aucun autre appareil ne sera branch Se reporter au tableau Caract ristiques pour conna tr
27. e le calibre des fusibles et des disjoncteurs AVERTISSEMENT Risque de secousses lectriques et d incendie S assurer que les renseignements du courant d arriv e Tension Hertz Phase s indiqu s sur la plaque signal tique du moteur de la pompe correspondent exactement au courant d arriv e Installer la pompe conform ment tous les codes de l lectricit en vigueur La longueur du cordon de l interrupteur flotteur automatique a t r gl e l usine 10 cm 4 pouces Cette longueur peut tre modifi e pour r pondre aux diff rentes gammes de pompage Se reporter Graphique des rendements L installateur doit s assurer que l interrupteur ne sera pas g n et qu il est r gl de fa on que le niveau du liquide arrive toujours au moins 5 cm 2 pouces au dessus de l aspiration de la pompe au plus bas niveau et sous le tuyau d arriv e dans le puisard au plus haut niveau Surcharges Un protecteur contre les surcharges a fonctionnement automatique log dans le moteur l emp chera de br ler en cas de surchauffe surcharge D s que le moteur refroidira le protecteur se r enclenchera automatiquement Si la surcharge se d clenche fr quemment en d terminer la cause Cet incident peut tre caus par un impulseur gripp une tension mauvaise basse ou une d fectuosit lectrique du moteur Si on pense que le moteur est d fectueux le faire r parer par un technicien comp tent
28. epara ciones repare bomba 660 a a co 457 Largo de Traba mm 356 Gama de Bombeo mm 457 559 660 762 864 965 413 0893SP Gr fico de rendimiento Largo de traba con respecto la gama de bombeo Servicio La bomba viene con lubricaci n permanente No se necesita aceitar ni engrasar durante un servicio normal AVISO No permita que la bomba marche en un sumidero seco Eso invalidar la garant a y podr perjudicar la bomba A ADVERTENCIA Tensi n peligrosa Puede causar choques quemaduras o muerte Antes de realizar servicios de reparaci n en la bomba desconecte la corriente el ctrica a la bomba y al conmu tador de control Despu s de sacar la cubierta de la esclusa y las tuber as de descar ga necesarias saque la bomba de la esclusa ADVERTENCIA Riesgo de choque el ctrico Puede que mar o matar No levante la bomba por medio del cord n de corri ente Consulte la secci n de Advertencia sobre la utilizaci n del cord n para levantar Coloque la bomba en un rea en donde se pueda limpiar a fondo Elimine todas las incrustaciones y los dep sitos en la bomba Sumerja toda la bomba en una soluci n desinfectante lej a con cloro durante una hora como m nimo antes de desarmar la bomba 14 La caja del motor de la bomba contiene un aceite especial de lub
29. grande puissance est peut tre requise La pompe ne se s arr te pas S assurer que l interrupteur ou que les flotteurs automatiques du contr leur fonctionnent ad quatement et de leur bon emplacement Se reporter aux instructions d installation de l interrupteur contr leur 11 Garantie limit e HYDROMATIC garantit l acheteur au consommateur d origine l Acheteur des pompes de puisard pompes d effluents pompes d eaux d gout l exception de la pompe de 2 1 2 po et les syst mes ensembles HYDROMATIC que celles ci seront exemptes de tout vice de mat riau et de fabrication pendant la p riode de garantie de 36 mois suivant la date de fabrication Nos garanties ne s appliquent pas aux produits ayant fait l objet de n gligence d une mauvaise utilisation d une mauvaise installation ou d un manque d entretien ad quat Sans aucune limitation des pr sentes la garantie des moteurs triphas s submersibles sera nulle et non avenue si ces moteurs sont branch s et fonctionnent sur le courant monophas par l interm diaire d un d phaseur II faut galement noter que les moteurs triphas s doivent tre prot g s par un relais de surcharge tripolaire thermocompens d clenchement extr mement rapide du calibre recommand sinon la garantie sera nulle et non avenue Le seul recours de l Acheteur et la seule responsabilit de HYDROMATIC consistent r parer ou remplacer au choix de
30. int de l arbre 8 Poser le moteur sur un support arqu en orientant son arbre la verticale vers le bas 9 D poser les boulons de fixation du moteur S parer le moteur et l arbre de la plaque d tanch it 10 Par derri re la plaque d tanch it chasser la t te du joint primaire Bien nettoyer la cavit du si ge Remontage REMARQUE S assurer que les surfaces du joint sont propres et pas endommag es Sur le bord ext rieur du corps du joint avec le ressort appliquer un peu de Permatex n 2 ou de produit quivalent Figure 1 1 Pousser le corps du joint neuf dans la cavit de la plaque d tanch it Figure 1 C t impulseur de la plaque d tanch it Permatex 23 Pousser le joint ms a r wae ici RS Si dans la cavit Figure 1 2 Remonter le moteur et l arbre sur la plaque d tanch it en utilisant les 4 boulons d pos s lors de l op ration 9 D montage REMARQUE Ne pas serrer exag r ment les boulons 3 Glisser la moiti rotative du joint sur l arbre Figure 2 REMARQUE Ne pas rayer ni entailler la surface du joint en carbure de silicone lorsqu on le fera passer par dessus l paulement de l arbre Les surfaces du joint doivent tre propres et non endommag es sinon le joint fuira Glisser la partie c ramique sur l arbre Figure 2 gt Remonter l impulseur la rondelle et l crou Inspecter attentivement le joint torique Le re
31. it over shaft shoulder Seal faces must be clean and undamaged or seal may leak Slide ceramic part onto shaft Ma Figure 2 4 Reassemble impeller washer and impeller nut 5 Inspect O Ring carefully replace if damaged If it is not nicked or scratched clean and reinstall NOTICE It is good practice to replace O Ring each time pump is serviced 6 Reconnect motor wires to connector Reference color code markings 7 Fill motor with clean dielectric oil Part No U197 8A To allow room for expansion oil level with cold motor should be about 1 4 6 mm above top of motor assembly Cord Connections Impeller side of seal plate Permatex cea Es Press seal Green White 18 Ber here i Se into cavity Si Red Black G Figure 1 reen a White Red Black Motor leads A WARNING 1 Attempting to lift or support pump by power cord can damage cord and cord o connections K Risk of electrical shock Can burn or kill Do not lift pump by power cord 2 Cord may pull apart exposing bare wires with possibility of fire or electrical shock 3 Lifting or supporting pump by power cord will void warranty 4 Use lifting ring or handle on top of pump for all lifting lowering of pump Disconnect power to pump before doing any work on pump or attempting to remove pump from sump REPAIR PARTS HTS50A1 Rope Handle Ring Power Cor
32. l overload may have tripped Test start pump if it starts and then stops immediately disconnect from power source for 30 minutes to allow motor to cool then reconnect to power source Check for cause of overheating overloading 7 If pump is completely inoperative or continues to malfunction consult your local serviceman DAIPOPN B Pump fails to empty sump 1 Be sure all valves in discharge piping are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required C Pump will not shut off 1 Check switch for proper operation and location See installation instructions for switch controller Limited Warranty HYDROMATIC warrants to the original consumer purchaser Purchaser or You of HYDROMATIC Sump Pumps Effluent Pumps Sewage Pumps other than 2 1 2 and Package Systems that they will be free from defects in material and workmanship for the Warranty Period of 36 months from date of manufacture Our warranty will not apply to any product that in our sole judgement has been subject to negligence misapplication improper installation or improper maintenance Without limiting the foregoing operating a three phase motor with single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick
33. local B La bomba no logra vaciar 1 Aseg rese de que todas las v lvulas en la v lvula de descarga est n totalmente el sumidero abiertas 2 Limpie la tuber a de descarga y la v lvula de retenci n 3 Verifique que no hayan bloqueos en la admisi n de la bomba o en el impulsor 4 El tama o de la bomba no es adecuado Es posible que se requiera una bomba de mayor capacidad C La bomba no se apaga Verifique la ubicaci n y el funcionamiento correcto del interruptor Consulte las instrucciones de la instalaci n del conmutador controlador 17 Garant a limitada HYDROMATIC le garantiza al comprador consumidor original el Comprador o Usted que las bombas de sumidero las bombas efluentes las bombas para aguas residuales a excepci n de la bomba de 2 1 2 y los sistemas paquetes de marca HYDROMATIC estar n libres de defectos en materiales y en mano de obra durante un per odo de garant a de 36 meses a partir de la fecha en que han sido fabricadas Nuestra garant a no se aplicar a ning n producto que a nuestro s lo juicio haya sido sometido a negligencia mal uso instalaci n inadecuada o mal mantenimiento Sin prejuicio a lo que antecede la garant a quedar anulada en el caso en que un motor trif sico se haya usado con una fuente de alimentaci n monof sica a trav s de un convertidor de fase Es importante indicador que los motores trif sicos deben estar protegidos por rel
34. mplacer s il est endommag S il n est pas entaill ou ray le nettoyer et le reposer REMARQUE Il est pr f rable de remplacer le joint torique chaque fois que la pompe est d mont e 6 Rebrancher les fils du cordon lectrique sur le connecteur Se reporter aux codes de couleur 7 Remplir le moteur d huile di lectrique propre num ro de pi ce U197 8A Laisser de la place pour la dilatation L huile doit arriver environ 6 mm 1 4 de pouce au dessus du moteur lorsqu il est froid Branchements des fils du moteur e a al la Vert En Blanc Roug Noir Vert Blanc Rouge Noir Fils du moteur AVERTISSEMENT 0 XA Risque de secousses lectriques pouvant causer des br lures voire la mort Ne pas lever la pompe par son cordon lectrique Avertissement concernant le levage par le cordon lectrique 1 Le cordon lectrique et ses connexions seront endommag s si on essaie de lever ou de supporter la pompe par son cordon lectrique 2 Le cordon lectrique peut se d tacher exposer les fils nus et causer un incendie voire des secousses lectriques 3 La garantie sera annul e si on soul ve ou supporte la pompe par son cordon lec trique 4 Toujours utiliser l anneau de levage ou la poign e de la pompe pour la lever ou l abaisser Avant d intervenir sur la pompe ou la sortir du puisard couper le courant qui l alimente
35. os de los fusibles y de los disyuntores A ADVERTENCIA Riesgo de choque el ctrico y de incendio Aseg rese de que la informaci n sobre el suministro de corri ente tensi n hertz fase que aparece en la placa de f brica del motor de la bomba corresponda exactamente con el suministro de corriente de entrada Instale la bomba conforme a todos los c digos el ctricos que correspondan El interruptor de flotador autom tico viene configurado de f bri ca con un largo de cadena de 4 pulgadas Este largo de traba se puede ajustar para adaptarse a una variedad de gamas de bombeo Consulte el gr fico de rendimiento El instalador debe asegurarse de que el conmutador no quede obstruido y que la gama se haya seleccionado de manera que el nivel del l quido permanezca 2 como m nimo por encima de la aspiraci n de la bomba en su nivel m s bajo y debajo de la tuber a de admisi n de la esclusa en su nivel m s alto Sobrecargas Un protector autom tico de sobrecarga en el motor proteger al motor para que no se queme debido a recalentamiento o sobrecarga Cuando el motor se enfr e el protector de sobrecarga se reposiciona r autom ticamente Si la sobrecarga se dispara con frecuencia verifique cu l es la causa Podr a ser un impulsor atascado tensi n baja o inadecuada o una falla el ctrica en el motor Si se sospecha que la raz n es una falla el ctrica en el motor haga que una persona experta en r
36. p ciale La garder propre et ne jamais la contaminer avec de l eau REMARQUE Si on doit d poser le couvercle du moteur pour intervenir sur la pompe vider l huile et la remplacer par une huile neuve lors du remontage Utiliser l huile indiqu e dans la liste des pi ces pi ce num ro U197 8A Au remontage faire le plein avec de l huile neuve NE PAS trop remplir Laisser de la place pour la dilatation L huile doit arriver environ 6 mm 1 4 de pouce au dessus du moteur lorsqu il est froid Remplacement de l impulseur AVERTISSEMENT Risque de secousses lectriques Avant toute intervention sur la pompe couper le courant qui l alimente Se reporter au sch ma de montage D montage 1 D visser les vis t te hexagonale puis s parer le moteur de la veloute Le poser sur son c t dans un endroit propre 2 D poser le bouchon d huile Tourner la pompe l envers pour vider l huile 3 Immobiliser l impulseur D poser son crou et sa rondelle 4 D visser l impulseur en le tournant gauche pour le nettoyer 5 Desserrer l crou du cordon puis tirer prudemment dessus pour le sortir du couvercle du moteur D brancher les fils du cordon les fils et les connecteurs sont cod s par couleur pour faciliter le remontage 6 D poser les vis t te creuse de fixation du couvercle du moteur sur la plaque d tanch it D poser le couvercle du moteur 7 D poser la moiti rotative du jo
37. r or brine Use with salt water or brine will void warranty PERFORMANCE GPM AT TOTAL FEET No flow Model 10 20 30 40 ga CAPACITY GALLONS MINUTE below HTS50A1 65 60 50 30 48 Flows are for 200 F water temperature SPECIFICATIONS Max Individual Dischage Switch Setting Model Motor Load Branch Circuit Adapter in inches mm Number HP Volts Phase Amps Required Amps Size inches On Off HTS50A1 1 2 115 1 12 0 15 2 17 8 452 8 8 224 293 WRIGHT STREET DELAVAN WI 53115 WWW HYDROMATIC COM PH 888 957 8677 2013 Pentair Ltd All Rights Reserved HYD505 Rev 03 04 13 INSTALLATION WARNING Risk of electrical shock Can burn or kill Do not lift pump by power cord See Cord Lift Warning NOTICE Install pump on a hard level surface cement asphalt etc Never place pump directly on earth clay or gravel surfaces Basin must be at least 18 457 mm in diameter and 30 762 mm deep Piping Piping must not be smaller than pump discharge When installed in an effluent system pipe must be capable of handling semi solids of at least 3 4 19 mm diameter The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid To meet minimum flow requirements of 2 ft per second 61 cm sec in discharge line size pipe as follows A Pipe Size Of Will Handle a Flow Rate
38. ri caci n Mantenga el aceite limpio y libre de agua en todo momento AVISO Siempre que se saque la cubierta del motor para realizar ser vicios de reparaci n saque el aceite y c mbielo por uno nuevo cuando vuelva a armar el motor Use solamente el aceite indicado en la lista de repuestos Repuesto No U197 8A Cuando llene con un aceite nuevo NO lo rellene demasiado Para permitir espacio para la expan si n el nivel del aceite con el motor fr o debe estar a 1 4 6 mm m s o menos por encima de la parte superior del ensamblaje del motor Cambio del impulsor y de la junta ADVERTENCIA Riesgo de choque el ctrico Desconecte la corriente el ctrica antes de realizar servicios de reparaciones en la bomba Consulte el dibujo de la unidad en la p gina 4 Desensamblaje 1 Destornille los tornillos prisioneros de cabeza hexagonal saque la unidad del motor de la voluta y col quela a un costado en un lugar limpio Saque el tap n del aceite Invierta la bomba para drenar el aceite Sostenga el impulsor saque la tuerca y la arandela del impulsor Destornille el impulsor gire en direcci n opuesta a las agujas del reloj para la limpieza 5 Afloje la tuerca del cord n y tire suavemente de la unidad del cord n hacia afuera de la cubierta del motor Desconecte los cables del juego del cord n los cables y el conector est n codi ficados a color para poder volver a instalarlos correctamente 6 Suelte los tornillos de c
39. s lectriques il faut tre tr s prudent lorsque l on remplace un fusible ou r enclenche les disjoncteurs Pour intervenir sur la bo te de commande ou les disjoncteurs ne pas se tenir dans l eau Avertissement li la Proposition 65 de la Californie AVERTISSEMENT Ce produit et les accessoires connexes contiennent des produits chimiques reconnus dans l Etat de la Californie comme pouvant provoquer des cancers des anomalies cong nitales ou d autres dangers relatifs la reproduction Pompes moteur monophas 8D Si on utilise un cordon lectrique fiche ne brancher cette fiche que dans une bo te de courant ad quatement mise la terre Si on branche la pompe sur une commande du syst me brancher le fil de mise la terre de la pompe sur la terre du syst me Description Ces pompes sont pr vues pour vacuer les eaux d gout les eaux r siduaires et r siduelles vider les puisards transf rer et faire circuler des liquides le pompage en g n ral et la lutte contre les inondations Le moteur de ces pompes peut tre monophas pour fonctionner sur le courant de 115 volts sont livr s avec un cordon fiche de 6 10 m tres 20 pieds 3 conducteurs dont un de mise la terre Pour les mod les HTS50 elle doit tre de 93 3 C 200 F REMARQUE Ces pompes ne sont pas con ues pour pomper de l eau sal e ni de la saumure Cette pratique annulera la garantie D bit
40. s de sobrecarga de disparo extra r pido con compensaci n ambiental de tres etapas del tama o recomendado de lo contrario la garant a quedar anulada Su nico recurso y la nica obligaci n de HYDROMATIC es que HYDROMATIC repare o reemplace los productos defectuosos a juicio de HYDROMATIC Usted deber pagar todos los cargos de mano de obra y de env o asociados con esta garant a y deber solicitar el servicio bajo garant a a trav s del concesionario instalador tan pronto como se descubra un problema No se aceptar ninguna solicitud de servicio bajo garant a que se reciba despu s del vencimiento del Per odo de Garant a Esta garant a no se puede transferir EXCEPCIONES Las bombas para aplicaciones especiales las bombas de sumidero con bater as de respaldo les bombas efluentes con filtro las bombas trituradoras y las bombas para aguas residuales de 2 1 2 de marca Hydromatic est n garantizadas por un per odo de 12 meses a partir de la fecha de compra o durante 18 meses a partir de la fecha de su fabricaci n seg n lo que ocurra primero HYDROMATIC NO SE HAR RESPONSABLE DE NING N DA O CONSECUENTE INCIDENTAL O CONTINGENTE LAS GARANT AS LIMITADAS QUE ANTECEDEN SON EXCLUSIVAS Y EN LUGAR DE TODA OTRA GARANT A EXPL CITA E IMPL CITA INCLUYENDO PERO SIN LIMITARSE A LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN ESPEC FICO LAS GARANT AS LIMITADAS QUE ANTECEDEN NO SE EXTENDER N M S ALL DEL PER
41. s garanties tacites Par cons quent il se peut que les limitations ou les exclusions stipul es dans les pr sentes ne s appliquent pas dans ce cas Ces garanties accordent des droits juridiques pr cis bien que l on puisse b n ficier d autres droits selon la province le territoire ou l tat dans lequel on r side La pr sente garantie limit e est entr e en vigueur le Ter juin 2011 et remplace toute garantie non dat e ou ant rieure cette date HYDROMATIC 293 Wright Street Delavan WI 53115 T l 888 957 8677 T l c 800 426 9446 Site Web hydromatic com 12 gt PENTAIR HYDROMATIC Informaci n sobre la seguridad Es importante que lea y observe todas las instrucciones de seguridad en este manual o en la bomba Este es un simbolo de alerta sobre la seguridad Cuando vea este simbolo en su bomba o en este manual busque para ver si hay alguna de las siguientes palabras de se al y est alerta sobre la posibilidad de lesiones personales Cd LL Advierte sobre peligros que ocasionar n lesiones personales graves muerte o da os considerables a la propiedad si se les ignora A ADVERTENCIA Advierte sobre peligros que pueden ocasion ar lesiones personales graves muerte o da os considerables a la propiedad si se ignoran 44 PRECAUCI N Advierte sobre peligros que ocasionar n o pueden ocasionar lesiones personales o da os a la propiedad menores si se ignoran La p
42. s operation plug directly into an electrical outlet or wire directly into switch box Connect pump to its own individual branch circuit with nothing else on the circuit See Specifications Chart for fuse or circuit breaker sizes L WARNING Risk of electrical shock and fire Be sure that power supply information Voltage Hertz Phase on pump motor nameplate matches incoming power supply exactly Install pump according to all electrical codes that apply Automatic float switch is factory set with a 4 tether length This tether length can be adjusted to accommodate a variety of pumping ranges See performance graph below The installer must ensure that the switch does not become obstructed and that the range is set so the liquid level remains a minimum of 2 above pump suction at the lowest level and below the basin inlet pipe at the highest level Overloads An automatic overload protector in the motor will protect motor from burning out due to overheating overloading When motor cools down protector automatically resets If overload trips frequently check for cause lt could be a stuck impeller wrong low voltage or electrical failure in motor If an electrical failure in the motor is suspected have it serviced by a competent repairman SERVICE 26 Nm D o Tether Length Inches p o wo a 6