Home

manual de instrucciones

image

Contents

1. EB CB e DE 5 O seal ese J8 PROBE Connecteur pour branchement sonde r chauffeur Code ACG4665 en option R1 TRIMMER R glage de la vitesse de ralentissement en ouverture et LOW SPEED fermeture R2 TRIMMER R gulateur lectronique de la force du moteur TORQUE DIP 11 ON DIP 12 OFF 1 gt PROG Touche destin e express ment la programmation TORQUE R GULATEUR LECTRONIQUE DE LA FORCE Le r glage de la force s effectue en tournant le Trimmer TORQUE qui sert varier la tension de sortie aux extr mit s du moteur en tournant dans le sens des aiguilles d une montre on augmente la force du moteur Cette force s inclut automatiquement 3 secondes apr s le d but de chaque man uvre Ceci pour donner le maximum de pouss e lors du d marrage NOTE SI CE TRIMMER EST REGLE APRES AVOIR EXECUTE LA PROCEDURE DE PROGRAMMATION IL EST POSSIBLE QUE LA MESURE DE DEPART RALLENTISSEMENT SUBISSE DES VARIATIONS EN PLUS OU EN MOINS PAR RAPPORT A LA PRECEDENTE DONC SI ON EXECUTE UN NOUVEAU REGLAGE DU TRIMMER IL EST CONSEILLE DE REFAIRE LA PROGRAMMATION DES TEMPS LOW SPEED REGULATEUR DE LA VITESSE DE RALENTISSEMENT Si DIP 8 est sur OFF le r glage du ralentissement est effectu en tournant le Trimmer LOW SPEED qui sert varier la vitesse du moteur en phase d approche de fin d ouverture ou de f
2. RA RAD AREY Xp now OX AA NNUS AO XX AM M de d ch M RR ol AAA DOO WARE 1 Op rateur K500 7 Limiteurs de course cames 2 Photocellules exterieures 8 Barre palpeuse m canique 3 Cr maill re Module 4 9 Barre palpeuse pneumatique ou Photonervure 4 S lecteur cl 10 Photocellules int rieures 5 Antenne radio 11 Potelets de support pour photocellules 6 Feu clignotant 12 Arr ts m caniques 1 CARACTERISTIQUES TECHNIQUES CARACTERISTIQUES TECHNIQUES K500 4 irr versibles pour portails coulissants dont le poids maximal est Poids maxi du portail kg 500 e 500 kg Gr ce l irr versibilit de cet op rateur le portail ne n cessite aucun type de serrure Forza max di spinta N 400 lectrique pour une fermeture efficace Le moteur est prot g par une sonde thermique qui interrompt momentan ment le Couple maxi Nn 35 mouvement en cas de non utilisation prolong e Module cr maill re 4 Alimentation et frequence 230V 50Hz 230V 60Hz Puissance moteur W 229 228 Absorption A 1 21 1 05 SSS Condensateur 10 i Cycles normatifs n 12 30s 2s 10 30s 2s 3 Cycles conseill s par jour n 300 k A Service 60 N Cycles cons cutifs garantis n 25 5m 70 777 KK 1 Type d huile COMLUBE LHITGREASE EP GR 2 Lil 2 ili Poids maximum kg 8 L 274 J L 25 Bruit db lt 70 Temperature de travail C 10 55 Indice de protection IP 54
3. il soit fourni des poign es adapt es sur le vantail ces poign es doivent tre positionn es de sorte ne pas cr er un danger durant leur utilisation l effort manuel pour mettre en mouvement le vantail ne doit pas exc der 225N pour les portes et portails en usage priv et 390N pour les portes et portails usage industriel et commercial valeurs indiqu es au paragraphe 5 3 5 de la norme EN 12453 16 50 min K500 WM 1 wi DOM FIXATION MOTEUR ET CR MAILLERE Le K500 est fourni avec une plaque de base qui permet le r glage en hauteur Ce r glage en hauteur est utile pour maintenir un jeu de 1 mm entre l engrenage de traction et la cr maill re La plaque de base est dot e de trois agrafes qui peuvent tre utilis es pour cimenter la plaque en terre En alternative il est possible de demander une plaque expr s cimenter pour le K500 code AC8108 est aussi possible de positionner le K500 avec sa plaque de base directement au dessus de la plaque cimenter d di e l op rateur K5 code ACG8101 La plaque de base du K500 est de plus dot e de 4 trous pour la fixation terre avec 4 vis tamponn es La cr maill re doit tre fix e une certaine hauteur par rapport au support du moteur Cette hauteur peut tre modifi e gr ce aux boutonni res pr sentes sur la cr maill re Le r glage en hauteur est effectu afin que lors du mouvement le portail ne puisse appuyer
4. 500 kg 4900 Ibs The irreversibility of this operating device allows you to avoid using any electric lock for an effective closing of the gate The motor is protected by an heat probe that temporary interrupts the operating cycle in case of prolonged use Measurements in mm inch 6 RA RAID EX d i XXE A DOCK ao K500 Max leaf weight kg 500 Rack 4 EEC Power supply 230V 50Hz 230V 60Hz Thrust force with constant turns N 400 Max torque Nm 9 5 Motor capacity W 229 228 Power absorbed A 1 21 1 05 Capacitor 10 Power supply 120V 120V 60Hz Thrust force with constant turns N 500 Max torque Nm 12 Motor capacity W 259 Power absorbed A 3 5 Capacitor 35 Normative cycles 230V 50Hz n 12 305 25 Normative cycles 220V 60Hz n 10 305 25 Normative cycles 120V 60Hz n 9 308 25 Daily operations suggested n 300 Service 60 Guaranteed consecutive cycles n 25 5m Grease COMLUBE LHITGREASE EP GR 2 Weight of electroreducer kg 8 Noise db lt 70 Working temperature C 10 55 Protection IP 54 25 INSTALLATION 500 CHECKING BEFORE THE INSTALLATION THE GATE SHALL MOVE FRICTIONLESS N B Gate features must be uniformed with the standards and laws in force The door gate can be automated only if it is in a good condition and its conditions comply with the EN 12604 norm The door gate leaf does not have a pedestrian door In the opposite case it is necessary to take
5. Componentes a instalar seg n la norma EN12453 USO DEL CIERRE TYPO DE MANDO Personas expertas Personas o fuera de un rea expertas Uso ilimitado p blica rea p blica en presencia de A B non posivel alguien con impulsos a la vista CoE CoE Ceno ej sensor con impulso no a la vista CoE CeD oE CeD oE ej telemando automatico CeD oE CeD oE CeD oE un ejemplo t pico son los cierres que no dan a la calle A Pulsador de mando en presencia de alguien es decir con acci n mantenida como c d ACG2013 B Interruptor de llave en presencia de alguien como c d ACG1010 C Regulacion de la fuerza del motor D Nervaduras como c d ACG3010 y o otros dispositivos que limitan las fuerzas entre limites de las normas EN 12453 Appendix A E Fotoc lulas como c d ACG8026 Da applicare cada 60 70 cm por toda la altura de la puerta hasta un m ximo de 2 5 m EN 12445 punto 7 3 2 1 DESBLOQUEO A efectuar tras haber cortado la alimentaci n el ctrica al motor Para poder abrir manualmente la cancela en el caso de que faltase la corriente el ctrica con introducir la llave y girarla 3 veces en sentido opuesto a las agujas del reloj Fig 4 Para poder realizar en modo seguro el desplazamiento manual de la puerta hay que controlar que Las manillas de la puerta que se han proporcionado sean id neas Estas manillas no est n posicionadas en modo de crear puntos de peligro durante su utilizo El esfuerzo m
6. 4 Per poter eseguire in modo sicuro la movimentazione manuale dell anta occorre verificare che sull anta siano presenti maniglie idonee tali maniglie siano posizionate in modo da non creare punti di pericolo durante il loro WW MAMMA utilizzo 2 w Lu lo sforzo manuale per muovere l anta non superi i 225N per i cancelli posti su siti privati i Ad ed i 390N per i cancelli posti su siti commerciali ed industriali valori indicati nel punto T A 5 3 5 della norma EN 12453 gt lt gt FISSAGGIO MOTORE E CREMAGLIERA II K500 viene fornito completo di una piastra di base che consente la regolazione in altezza Questa regolazione in altezza utile per mantenere un agio di 1 mm tra l ingranaggio di traino e la cremagliera La piastra di base dotata di tre zanche che possono essere utilizzate per la cementazione a terra In alternativa possibile richiedere l apposita piastra da cementare per K500 cod ACG8108 altresi possibile posizionare il K500 con la relativa piastra di base direttamente al di della piastra da cementare dedicata all operatore K5 cod ACG8101 La piastra di base del K500 inoltre dotata di 4 fori per il fissaggio a terra con 4 viti ad espansione La cremagliera deve essere fissata a una certa altezza rispetto all appoggio del motore Questa altezza pu essere variata grazie alle asole presenti sulla cremagliera La registrazione in altezza viene fatta af
7. N DE LOS C DIGOS DE RADIO APERTURA TOTAL 30 C DIGOS MAX S LO MODELOS CRX La programaci n puede ser efectuada nicamente con la cancela detenida 1 Colocar el DIP 1 en posici n ON y sucesivamente el DIP2 en ON 2 El led rojo DL1 de programaci n parpadea con una frecuencia de 1 seg ON y 1 seg OFF durante 10 segundos 3 Presionar la tecla del mando a distancia normalmente el canal A dentro de los 10 segundos programados Si el mando a distancia se ha memorizado correctamente el led DL2 verde emite un parpadeo 4 El tiempo de programaci n de los c digos se renueva autom ticamente para poder memorizar el mando sucesivo 5 Para terminar la programaci n dejar transcurrir 10 seg o bien presionar durante un instante el pulsador PROG El led rojo DL1 de programaci n deja de parpadear 6 Volver a colocar el DIP 1 en posici n OFF y el DIP 2 en OFF 7 Final del procedimiento PROCEDIMIENTO PARA LA CANCELACI N DE TODOS LOS C DIGOS DE RADIO DESTINADOS A LA APERTURA TOTAL La cancelaci n puede ser efectuada nicamente con la cancela detenida 1 Colocar el DIP 1 en posici n ON y sucesivamente el DIP 2 en ON 2 El led rojo DL1 de programaci n parpadea con una frecuencia de 1 seg ON y 1 seg OFF durante 10 segundos 3 Presionar y mantener presionado el pulsador PROG durante 5 segundos La cancelaci n de la memoria es indicada mediante dos parpadeos del led verde DL2 4 El led rojo DL1 de programaci n
8. SELETTORI A CHIAVE BLOCK E PULSANTIERA FLAT FOTOCELLULE FIT SLIM COSTA MECCANICA A CONNESSIONI Ji giwocax NON TOCCARE IL PONTICELLO za SE VIENE RIMOSSO L OPERATORE NON FUNZIONA J2 AERIAL LSC Contatto finecorsa che ferma la chiusura Antenna radio LSO Contatto finecorsa che ferma l apertura COM Comune dei contatti PED BUTT Contatto comando pedonale J3 L N Alimentazione 230Vac 50 60Hz 120V 60Hz a richiesta J4 TERRA Collegamento dei conduttori di terra Obbligatorio J5 RADIO Connettore per radio ricevitore esterno 24Vdc modelli non CRX Modulo radio incorporato modelli CRX J6 A TEST Positivo per alimentazione autotest costa a 24Vdc A Positivo alimentazione accessori a 24Vdc A Negativo per alimentazione accessori a 24Vdc COM Comune dei contatti POSITIVO KBUTT Contatto impulso singolo NA PHOT Contatto fotocellule NC EDGE Contatto coste in apertura e chiusura NC A Buzzer Collegamento segnalatore sonoro 24Vdc max 200 mA NEGATIVO J hz Lampeggiatore max 40W z t pegg U Collegamento comune motore MOTOR V W Collegamento invertitori e condensatore motore MOTOR J8 PROBE Connettore per collegamento sonda riscaldatore cod ACG4665 opzionale RELE E COMANDO MOTORE K1 gt Comando lampeggiatore K2 gt Comando direzione chiusura K3 gt Comando direzione apertura 01 gt TRIAC Comando motore in apertura e chiusura B SETTAGGI MICROINTERRUTTORI
9. isolation ou d une isolation renforc e par rapport aux parties sous tension Toutes les entr es sont contr l es par un circuit int gr programm qui effectue un auto contr le lors de chaque mise en route SOLUTION DES PROBLEMES Apr s avoir effectu tous les raccordements en suivant attentivement le sch ma et avoir positionn le portail en position interm diaire v rifier l allumage correct des leds DL4 DL7 DL8 Si les leds ne s allument pas en maintenant toujours le portail en position interm diaire v rifier les points ci apr s et ventuellement remplacer les composants qui ne fonctionnent pas DL3 teinte Fin de course arr t ouverture en panne DL4 teinte Fin de course arr t fermeture en panne DL7 teinte Photocellules en panne DL8 teinte Bande de contact de s curit en panne Si la bande de contact n est pas reli e effectuer la connexion entre COM et EDGE Durant le fonctionnement avec op rateur pr sent avec DIP n 1 sur ON v rifier que durant l ouverture la led verte DL6 s allume et que durant la fermeture la led rouge DL5 s allume Dans le cas contraire invertir les bornes V et W sur le bornier du moteur SOLUTION Apr s avoir effectu les diff rents raccordements et avoir allum le courant toutes les leds sont teintes Le moteur ouvre et ferme mais n a pas de force et se d place lentement Le portail effectue l ouverture mais ne se referme pas apr s le
10. n y de las leyes actualmente vigentes CONSERVAR CUIDADOSAMENTE ESTAS INSTRUCCIONES 1 En el caso de que no sea previsto en la central el ctrica instalar antes de la misma un interruptor de tipo magnetot rmico omnipolar con una abertura m nima de los contactos de 3mm que d un sello de conformidad con las normas internacionales Este dispositivo tiene que estar protegido contra cierres accidentales por ejemplo instal ndolo dentro de un panel cerrado a llave 2 Para la secci n y el tipo de los cables RIB aconseja utilizar cables de tipo HO5RN F con secci n m nima de 1 5mm e igualmente atenerse a la norma IEC 364 y a las normas de instalaci n del propio Pa s Posicionamiento eventual de un par de fotoc lulas El rayo de las fotoc lulas no debe estar a m s de 70 cm de altura desde el suelo y a una distancia de la superficie de movimiento de la puerta no superior a 20 cm El correcto funcionamiento tiene que ser controlado al final de la instalaci n de acuerdo con el punto 7 2 1 de la EN 12445 4 Para satisfascer los l mites impuestos por la EN 12453 si la fuerza de punta supera el l mite normativo de 400 N es necesario recurrir al control de presencia activa en toda la altura de la puerta hasta a 2 5m max Las fotoc lulas en este caso se tienen que colocar en el exterior entre las columnas y en el interior por todo el recorrido de la parte m vil cada 60 70 en toda la altura de las columnas de la cancela has
11. sactiv travers le DIP3 ON activ FERMETURE AUTOMATIQUE AVEC OUVERTURE PIETONNE Les temps de pause avant d avoir la fermeture automatique pi tonne du portail sont enregistr s durant la programmation pi tonne Le temps de pause maximum est de 5 minutes Le temps de pause peut tre activ ou d sactiv par l interm diaire du DIP3 ON actif FONCTIONNEMENT DES ACCESSOIRES DE S CURIT PHOTOCELLULE COM PHOT DIP 4 OFF gt S il existe un obstacle dans le rayon des photocellules lorsque le portail est ferm celui ci ne s ouvre pas Pendant le fonctionnement les photocellules interviennent aussi bien en phase d ouverture avec reprise du mouvement en ouverture qu apr s de la lib ration des photocellules qu en phase de fermeture avec reprise du mouvement inverse qu apr s de la lib ration des photocellules DIP 4 ON gt S il existe un obstacle dans le rayon des photocellules lorsque le portail est ferm et que l on actionne la commande d ouverture le portail s ouvre pendant l ouverture les photocellules n interviennent pas Les photocellules n interviendront qu en phase de fermeture avec r tablissement du mouvement inverse apr s une seconde m me si ces derni res restent engag es NOTE si cette entr e n est pas utilis e ex cuter un pont entre les bornes COM PHOT BARRE PALPEUSE PNEUMATIQUES MECANIQUES 0U PHOTOCORDON COM EDGE Si le barre palpeuse intervient en ouverture il ren
12. 2 of the EC Directive 2006 42 s putting into service before being found compliant with what is provided by the Directive ed into a system made fications to which respect we point out the ban on i funktionieren und wurde konstruiert um in einen von anderen Bestandteilen zusammengesetzten System eingebaut zu werden Das Produkt f llt deswegen den anto en el Art 6 p rrafo 2 Legal Representative V Rasconi Antonio 99 K500 07069 DAC42x16 RA aa ARTS bas EEL1529 A K Sc DAC39x95 222 DAESSx16 y ut CCA1325 cpLiz38 f 0 9 I Q I L gt a X CAL1166 CCA1179 SA er N lt i AN e we a e EM j Y ch E CCM6202MZZ massoni DAS42x16 8 gt AI CEL1520 Ae D E y d I Li e gt rT _JCM01345 Y Ze CMO1246 DDD6MA CNN CPL1179 CELTI YZ TES DSB6x25 Y 104 ua a CELISQ VO A 5 Dscax207 Wo Y DAC29x95 lt ceL1425 LE M cc Ze ni BA10087 4 f D 1 01045 N CTC1090 r N N i DTB63X25 I 7 1 F N 061071 1 gt Ta CME1132 CTC1293 i A CCA1324 J e k ccastre ACG8672 Codice Denominazione Particolare CEL1520 Supporto sella CTC1404 Paraolio 25x40x7 AC07069 Scheda K2007 230 50 60Hz CEL1529 Cavetto terra CVA1060 Gu
13. ACCETTA NESSUNA RESPONSABILIT per eventuali danni provocati dalla mancata osservanza nell installazione delle norme di sicurezza e delle leggi attualmente in vigore CONSERVARE CON CURA QUESTE ISTRUZIONI 1 Se non previsto nella centralina elettrica installare a monte della medesima un interruttore di tipo magnetotermico onnipolare con apertura minima dei contatti pari a 3mm che riporti un marchio di conformit alle normative internazionali Tale dispositivo deve essere protetto contro la richiusura accidentale ad esempio installandolo dentro quadro chiuso a chiave 2 Per la sezione ed il tipo dei cavi RIB consiglia di utilizzare un cavo di tipo HOSRN F con sezione minima di 1 5mm e comunque di attenersi alla norma IEC 364 e alle norme di installazione vigenti nel proprio Paese 3 Posizionamento di un eventuale coppia di otocellule Il raggio delle fotocellule deve essere ad un altezza non superiore a 70 cm dal suolo e ad una distanza dal piano di movimento dell anta non superiore a 20 cm Il loro corretto funzionamento deve essere verificato a fine installazione in accordo al punto 7 2 1 della EN 12445 4 Peril soddisfacimento dei limiti imposti dalla El il limite normativo di 400 sull intera altezza del cancello fino a 2 5 N 12453 se la forza di picco supera necessario ricorrere alla rilevazione di presenza attiva m max Le fotocellule in questo caso sono da applicare all esterno t
14. ACG8039 RADIO NUMERIC CODER for mechanical and electrical safety strip Batteries not included RED allows to make a system made with edges fixed to the moving shutter without having to use cable sleeving systems It complies with EN13849 1 2007 Standard if installed with an RIB Electronic Board it is built in code ACG9434 a Class 2 Device code ACG6202 to wall code ACG9436 BLOCK Wi Fi SPARK Wi Fi a KEY SELECTOR WITHOUT WIRES code ACG6098 BLINKER WITHOUT WIRES code ACG7064 LATERAL SUPPORT code ACG7042 34 ANLAGEN LAY OUT 5 6 MA Gd AMAN Na ve tg M AW 1 44 RR don RARI D MN M 9 Ju W i ENS CRIMEN APA SSL 1 Betriebsger t K500 7 Laufbegrenzer Nocken 2 Externe Fotozellen 8 Mechanische Kontaktleisten 3 Zahnstange Modul 4 9 Pneumatische Kontaktleisten oder Fotokontaktleiste 4 Schl sselw hlschalter 10 Interne Fotozellen 5 Radioantenne 11 Stands ulen f r Fotozellen 6 Blinkleuchte 12 Mechanische Anschl ge 1 TECHNISCHE EIGENSCHAFTEN TECHNISCHE EIGENSCHAFTEN K500 Irreversible Betriebsger te f r Schiebetore mit einem Maximalgewicht von 500 kg Max Torgewicht kg 500 Durch die Irreversibilit t dieses Betriebsger ts ben tigt das Tor zur wirkungsvollen Max Schubkraft N 400 Verriegelung kein elektrisches Sicherheitsschloss Toun N 95 Der Motor wird durch eine thermische Sonde gesch tzt die im Fall eines langen BUD Einsa
15. Mesures en mm inch 1 5 E INSTALLATION K500 CONTR LE PR INSTALLATION LE PORTAIL DOIT SE D PLACER SANS FROTTER N B est imp ratif d uniformiser les caract ristiques du portail avec les normes et les lois en vigueur La portail peut tre automatis e seulement si elle est en bon tat et qu elle est conforme la norme EN 12604 Le vantail ne doit pas comporter de portillon int gr Dans le cas contraire il sera opportun de prendre les pr cautions d crites au point 5 4 1 de la EN 12453 interdire par le biais d un contact raccord aux bornes adapt es de la platine lectronique la mise en marche de l automatisme si le portillon est ouvert Ne pas g n rer de zone d crasement par exemple entre le vantail ouvert et la cloture Outre les fins de course pr sents sur l op rateur il est n cessaire d installer des but es m caniques fixes l extr mit de chaque course de sorte arr ter le portail en cas de dysfonctionnement des fins de course lectriques Pour cela les but es m caniques doivent tre dimensionn es de sorte supporter la pouss e statique du moteur ajout e l nergie cin tique du portail 12 fig 2 Les poteaux du portail doivent avoir des glissi res anti d raillement sur la partie sup rieure fig 3 afin d viter tout d crochage accidentel N B liminer les arr ts m caniques du type indiqu d crit dans la figure 3 Il ne devra y avoir aucun arr t
16. Nivel de protecci n IP 54 45 INSTALACI N K500 CONTROL PRE INSTALACI N LA VERJA TIENE QUE MOVERSE SIN ROCES Es obligatorio uniformar las caracter sticas de la verja a las normas y leyes en vigor La puerta puede ser automatizada s lo si se encuentra en buen estado y responde a la norma EN 12604 La puerta no tiene que tener puertas peatonales De lo contrario se tendr n que tomar las oportunas precauciones de acuerdo con el punto 5 4 1 de la EN12453 por ejemplo impedir el movimiento del motor cuando la puertecilla est abierta gracias a un microinterruptor debidamente conectado a la central No hay que generar puntos en los que se pueda quedar atrapado por ejemplo entre la puerta de la cancela y la verja Adem s de los finales de carrera presentes en la unidad es necesario que en cada una de las dos posiciones extremas del recorrido haya un seguro mec nico fijo que pare la cancela en caso de mal funcionamiento del final de carrera Con este objetivo el seguro mec nico tiene que ser dimensionado para poder resistir el empuje est tico del motor m s la energ a cin tica de la cancela 12 Fig 2 Las columnas de la verja tienen que llevar en su parte superior unas gu as anti descarrilamiento Fig 3 para evitar desenganches involuntarios N B Eliminar los topes mec nicos del tipo descrito en el Figura 3 No tiene que haber topes mec nicos por encima de la verja porque no son suficientemente seguros
17. U MOTOR Connexion groupe moteur V W MOTOR Connexion inverseurs et condensateur moteur RELAIS ET COMMANDE MOTEUR K1 gt Commande clignotant K2 gt Commande direction fermeture K3 gt Commande direction ouverture Q1 gt TRIAC Commade moteur en ouverture et fermeture ON ai MICROINTERRUPTEURS POUR PROCEDURES CONTR LE DU SENS DE ROTATION DU MOTEUR ON POINT DIP2 PROGRAMMATION DES TEMPS ON POINT D DIP 2 1 PROGRAMMATION DES TEMPS D OUVERTURE PIETONNE DIP 2 ON SUIVI DE DIP 1 ON POINT D DIP 1 2 MEMORISATION ANNULATION CODES RADIO COMMANDE OUVERTURE TOTALE DIP 1 ON suivi de DIP 2 ON POINT E UNIQUEMENT POUR MODELES CRX DIP 1 3 MEMORISATION ANNULATION CODES RADIO COMMANDE OUVERTURE PIETONNIERE DIP 1 ON suivi de DIP 3 ON POINT F UNIQUEMENT POUR MODELES CRX MICRO INTERRUPTEURS DE GESTION Temps d attente avant la fermeture automatique ON DIP 4 Photocellules toujours actives OFF Photocellules actives uniquement en phase de ermeture ON P5 Pr clignotement ON Clignotement normal OFF P6 Commande impulsion simple K BUTT et RADIO pas pas ON automatique OFF P7 lectronique ON active P8 Ralentissement OFF actif P9 D part graduel ON actif P 10 Habilitation TEST monitorage cordon ON habilit OFF d shabilit B AJUSTEZ LES MICROINTERRUPTEURS DE CONTROLE H eu uuu e
18. con DIP 4 OFF Sistemare o sostituire il relativo contatto Impulso K sempre inserito Controllare e sostituire eventuali pulsanti o micro interruttori del selettore Accertarsi che il DIP 8 sia in posizione OFF rallentamento abilitato Eseguire l apprendimento dei tempi tramite procedura con DIP 2 Verificare regolazione trimmer LOW SPEED 122 OPTIONAL Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione PIASTRA DA CEMENTARE cod ACG8108 FIT SLIM FOTOCELLULE DA PARETE cod ACG8032 COPPIA DI COLONNINE PER FIT SLIM cod ACG8065 Le fotocellule FIT SLIM hanno la funzione di sincronismo in corrente alternata e portata di 20 m Sono applicabili pi coppie di fotocellule ravvicinate grazie al circuito sincronizzatore Aggiungere il TRASMETTITORE TX SLIM SYNCRO cod ACG8029 per sincronizzare fino a 4 coppie di fotocellule TOUCH COSTA MECCANICA L 2 m CERTIFICATA EN 13849 2 2008 CATEGORIA 3 cod ACG3015 PROBE 4 Sonda di rilevamento temperatura ambiente motore per riscaldamento dello stesso in climi particolarmente freddi fino a 30 C collegare a connettore J8 cod ACG4665 CREMAGLIERA MOD 4 IN NYLON con angolare zincato in barre da 1 m Ideale per cancelli fino a 1000 kg 2200 lbs di peso im cod ACS9000 10 m 1 m x 10 cod ACS9001 FIT SYNCRO FOTOCELLULE FIT SYNCRO DA PARETE cod ACG8026 Portata settabile 10 20 m Sono applicabili pi
19. con cavetto CTC1307 Anello di tenuta OR2037 DTE8x40 Vite TE 8x40 UNI5739 C MADE IN ITALY Om Questo prodotto stato completamente progettato e costruito in Italia Ce produit a t compl tement d velopp et fabriqu en Italie This product has been completely developed and built in Italy Dieses Produkt wurde komplett in Italien entwickelt und hergestellt Articulo totalmente proyectado y producido en Italia E 25014 CASTENEDOLO BS ITALY COMPANY WITH Via Matteotti 162 QUALITY SYSTEM Tel 39 030 2135811 CERTIFIED BY DNV GL automatismi per cancelli Far 2009021358279 REESE automatic entry systems www ribind it ribind ribind it 8 028265 110786 gt Cod CVA1654 09042015 Rev 23
20. der Klasse 2 dar Kode ACG6202 SPARK Wi Fi a Kode ACG7064 Kode ACG7042 BLINKER OHNE KABEL SEITENLAGER DISPOSICI N DE LA INSTALACI N ASE AA BAAD LOCK XD CC Gu GO Se RAR oct NW M NN ODO PANNI 1 Operador K500 7 Limitadores de recorrido leva 2 Fotoc lulas externas 8 Nervadura mec nica 3 Cremallera M dulo 4 9 Nervadura neum tica o Fotonervadura 4 Interruptor de llave 10 Fotoc lulas internas 5 Antena de radio 11 Columnas para las fotoc lulas 6 Intermitente 12 Topes mec nicos 1 CARACTER STICAS T CNICAS CARACTER STICAS K500 T CNICAS neun irreversibles para verjas correderas con un peso m ximo de 500 Peso m x verja kg 500 La irreversibilidad de este operador permite que la verja no requiera ning n tipo de Fuerza m x N 400 cerradura el ctrica para un cierre eficaz Coppia m x Nm 9 5 El motor est protegido por una sonda t rmica que en caso de uso prolongado interrumpe moment neamente el movimiento Cremallera m dulo 4 Alimentaci n y frecuencia 230V 50Hz 230V 60Hz Potencia motor W 229 228 _ _ Absorci n A 1 21 1 05 Condensador 10 Ciclos normativos n 12 30s 2s 10 305 25 vi Ciclos diarios sugeridos n 300 W amp Servicio 60 pner Ciclos garantizados n 25 5m A Engrase COMLUBE LHITGREASE EP GR 2 2457 Peso m x Kg 8 7 7 7 Nivel de ruido db lt 70 Temperatura de trabajo C 10 55 Medidas en mm inch
21. guasto DL7 spento Fotocellule guaste DL8 spento Costa sicurezza guasta In caso la costa non sia collegata eseguire il ponticello fra Com e Edge Durante il funzionamento a uomo presente con DIP n 1 in ON verificare che durante l apertura si accenda il led verde DL6 e che durante la chiusura si accenda il led rosso DL5 In caso contrario invertire i morsetti V e W sulla morsettiera del motore SOLUZIONE Dopo aver effettuato i vari collegamenti e aver dato tensione tutti i led sono spenti Il motore apre e chiude ma non ha forza e si muove lentamente II cancello esegue l apertura ma non chiude dopo il tempo impostato II cancello non apre e non chiude azionando i vari pulsanti K e Radio Azionando il pulsante K il cancello non esegue nessun movimento La fase di rallentamento non viene eseguita Verificare l integrit dei fusibili F1 e F2 In caso di fusibile interrotto usarne solo di valore adeguato F2 5A F1 100mA Verificare la regolazione dei trimmers TORQUE e LOW SPEED Accertarsi di avere settato il DIP 3 in ON Pulsante K BUTTON sempre inserito in modalit di funzionamento automatico DIP 6 OFF Sostituire pulsante o switch del selettore Autotest costa fallito verificare i collegamenti tra quadro elettronico e alimentatore per coste Attenzione se non si sta utilizzando un alimentatore per coste il DIP 10 deve essere in posizione OFF Contatto costa sicurezza guasto Contatto fotocellule guasto
22. la programmazione TORQUE REGOLATORE ELETTRONICO DELLA FORZA La regolazione della forza viene fatta ruotando il Trimmer TORQUE che serve a variare la tensione di uscita ai capi del motore ruotando in senso orario si da pi forza al motore Tale forza si include automaticamente dopo 3 secondi dall inizio di ogni manovra Questo per dare il massimo di spunto al motore al momento della partenza NOTA SE QUESTO TRIMMER VIENE REGOLATO DOPO AVERE ESEGUITO LA PROCEDURA DI PROGRAMMAZIONE E POSSIBILE CHE LA MISURA DI INIZIO RALLENTAMENTO SUBISCA DELLE VARIAZIONI IN PIU O IN MENO RISPETTO ALLA PRECEDENTE PERTANTO SE SI ESEGUE UNA NUOVA REGOLAZIONE DEL TRIMMER SI CONSIGLIA DI RIESEGUIRE LA PROGRAMMAZIONE DEI TEMPI LOW SPEED REGOLATORE DELLA VELOCITA DI RALLENTAMENTO Se DIP8 su OFF la regolazione del rallentamento viene fatta ruotando il Trimmer LOW SPEED che serve a variare la velocita del motore in fase di accostamento di fine apertura e chiusura ruotandolo in senso orario si da pi velocit al motore Il rallentamento viene determinato automaticamente dalla centralina in fase di programmazione tempi e viene attivato a circa 50 60 cm prima del raggiungimento del finecorsa di apertura 0 di chiusura FRENO ELETTRONICO Se non usato il rallentamento dip 8 ON consigliamo di abilitare il dip 7 a ON usufruendo di un freno elettronico che limita l inerzia del cancello quando raggiunge i finecorsa elettrici PARTENZA GRADUALE Con D
23. permanece activo y es posible introducir nuevos c digos siguiendo los procedimientos arriba descritos 5 Volver a colocar el DIP 1 en posici n OFF y el DIP 2 en OFF 6 Final del procedimiento SE ALIZACI N DE MEMORIA LLENA C DIGOS DE RADIO DESTINADOS A LA APERTURA TOTAL La se alizaci n se puede obtener nicamente con la cancela detenida 1 Colocar el DIP 1 en posici n ON y sucesivamente el DIP 2 en ON 2 El led verde DL2 parpadea 6 veces indicando que la memoria est saturada 30 c digos presentes 3 Sucesivamente el led DL1 de programaci n permanece activo por 10 segundos consintiendo la eventual cancelaci n total de los c digos 4 Volver a colocar el DIP 1 en posici n OFF y DIP 2 en OFF 5 Final del procedimiento F PROGRAMACI N DE LOS C DIGOS DE RADIO APERTURA PEATONAL 30 C DIGOS M X S LO MODELOS CRX La programaci n puede ser efectuada nicamente con la cancela detenida 1 Colocar el DIP 1 en posici n ON y sucesivamente el DIP 3 en ON 2 El led rojo DL1 de programaci n parpadea con una frecuencia de 1 seg ON y 1 seg OFF durante 10 segundos 3 Presionar la tecla del mando a distancia normalmente el canal B dentro de los 10 segundos programados Si el mando a distancia ha sido correctamente memorizado el led DL2 verde emite un parpadeo 4 El tiempo de programaci n de los c digos se renueva autom ticamente para poder memorizar el mando sucesivo 5 Para fi
24. stellen gt Led DL1 beginnt zu blinken 3 Die Schalttaste PROG dr cken diese gedr ckt halten die Bewegung erfolgt bei Personenanwesenheit ffne stopp schliesse stopp ffne usw gt LED GR N DL6 OPEN erleuchtet und das Tor muss sich ffnen geschieht dies nicht die Schalttaste PROG loslassen und die Dr hte des Motors V und W invertieren dann bei Kontakt mit dem elektrischen Endlauf stoppen geschieht dies nicht die Schalttaste PROG loslassen und die zwei Dr hte des Endlaufes LSO und LSC umstellen 4 Die Schalttaste PROG dr cken diese gedr ckt halten gt LED ROT DL5 CLOSE erleuchtet und das Tor muss sich nun schlieBen und bei Kontaktnahme mit dem elektrischen Endlauf stoppen 5 Nach 2 sek und in 10sek korrekten arbeiten des Antriebs ob in auf oder Zulauf der elektronische Kraftregler hat sich selbst kontrolliert Wichtig ist nat rlich die Einstellung des Kraftreglers TORQUE 6 Nach 10sek korrekten arbeiten des Antriebes ob in auf oder Zulauf der automatische Langsamlauf ist aktiviert wenn DIP 8 ist in in OFF Position und wenn der Kraftregler TORQUE steht auf minimaler Einstellung 7 Am Ende der Kontrolle und nach der Reglerstellung stellen Sie DIP1 in die Position OFF Die LED DL1 schaltet sich aus und meldet damit dass sie von der Kontrolle abgesprungen ist NB W hrend dieser Kontrolle sind der Encoder und die Photozellen nicht aktiv D ZEITENPROGRAMMIERUNG FUR DIE TOTA
25. the appropriate steps in accordance with EN 12453 norm for instance by preventing the operation of the motor when the pedestrian door is opened by installing a safety microswitch connected with the control panel Besides the electrical or mechanical limit switches available on the operators there must be on both ends of the installation a fixed mechanical stopper which stop the gate in the unlikely event of ill functioning of limit swithces on the operators For this reason the fixed mechanical stopper must be of an adeguate size to withstand the static and kinetic forces generated by the gate 12 fig 2 Gate columns shall have anti derailment guides on their top fig 3 to avoid the unintentional gate release N B Remove mechanical stops like the one in fig 3 No mechanical stops shall be on top of the gate since these mechanical stops are not safe enough Parts to install meeting the EN 12453 standard USE OF THE SHUTTER COMMAND TYPE Skilled persons e out of public Skilled persons Unrestricted use public area area at mames A B non possibile operation with visible impulses CorE CorE Cand D or E e g sensor with not visible impulses Cor E C and D or E C and D or E e g remote control device automatic C and D or E C and D or E C and D or E a typical example are those shutters which do not have access to any public way A Command button with manned operation that is operating as
26. 0 Sekunden verlaufen lassen oder f r einen Augenblick die Taste PROG dr cken Das rote LED DL1 f r die Programmierung h rt auf zu blinken 6 DIP 1 und DIP 2 erneut auf OFF stellen 7 Ende des Vorgangs L SCHUNG ALLER FUNKCODES F R DIE GESAMT FFNUNG Die L schung kann nur bei stillstehendem Tor vorgenommen werden 1 Zuerst DIP 1 auf ON und danach DIP 2 auf ON stellen 2 LED DU rot f r die Programmierung blinkt im Abstand von 1 Sekunde bei ON und 10 Sekunden bei OFF 3 Die Taste PROG dr cken und 5 Sekunden eingedr ckt halten Die L schung des Speichers wird durch zwei Blinker des gr nen LEDs DL2 angezeigt 4 Das rote LED DL1 f r die Programmierung bleibt aktiviert und man kann neue Codes eingeben siehe die vorhergehende Beschreibung 5 DIP 1 und DIP 2 erneut auf OFF stellen 6 Ende des Vorgangs ANZEIGE SPEICHER FUNKCODES F R GESAMT FFNUNG VOLL Die Anzeige kann nur bei stillstehendem Tor erfolgen 1 Zuerst DIP 1 auf ON und danach DIP 2 auf ON stellen 2 Das gr ne LED DL2 blinkt 6 Mal und zeigt an dass der Speicher voll ist 30 Codes vorhanden Danach bleibt das LED DL1 f r die Programmierung f r 10 Sekunden aktiviert und erm glicht eine eventuelle Gesamtl schung der Codes 4 DIP 1 und DIP 2 erneut auf OFF stellen 5 Ende des Vorgangs co gue gt oo 4 F PROGRAMMIERUNG FUNKCODES FUSSGANGER OFFNUNG MAX 30 CODES NUR MODELLE CRX Die P
27. 1 bestimmt ist Die Basisplatte des K500 verf gt auBerdem ber 4 Bohrl cher mit 4 Expansionsschrauben r die Bodenfixierung Die Zahnstange muss gegen ber der Motorhalterung in einer entsprechendenden H he befestigt werden Diese H he kann mittels an der Zahnstange befestigten sen ver ndert werden Die H henregulierung muss solange erfolgen bis das Tor sich w hrend der Bewegung nicht mehr auf das Zugrad K aufst tzt Abb 5 6 U a D m die Zahnstange am Tor zu befestigen m ssen 5 mm Bohrungen und M6 Gewinde usgef hrt werden as Zugrad muss ca 1mm Spiel gegen ber der Zahnstange besitzen E E Ej y pe Hi Kei 223 Abmessungen in mm BEFESTIGUNG DES ENDSCHALTERS Um den Lauf des mobilen Teils zu beenden m ssen zwei Nocken an den Enden der Zahnstange positioniert werden Abb 9 Die Regulierung des ffnungs und Schlie laufes wird erhalten indem diese entlang der Zahnstangenz hne verschoben werden Um die Zahnstangennocken festzustellen m ssen die mitgelieferten Schrauben am Boden befestigt werden ANMERKUNG AuBer den o g elektrischen Feststellnocken m ssen ebenfalls robuste mechanische Anschl ge montiert werden die ein Herausgleiten des Tors aus den oberen F hrungen verhindern INSTANDHALTUNG Die Entriegelung darf nur von spezialisiertem Personal und erst nach dem Abschalten der elektrischen Motorstromversorgung erfolgen Den F hrungslauf bei geschlossenem T
28. 45 Le c blage des divers composants lectriques externes l op rateur par exemple photocellules clignotants etc doit tre effectu selon la 60204 1 et les modifications apport es celle ci dans le point 5 2 2 de la EN 12453 Le montage ventuel d un tableau pour la commande manuelle du mouvement doit tre fait en positionnant le tableau de facon ce que la personne qui l actionne ne se trouve pas en position de danger de plus il faudra faire en sorte que le risque d actionnement accidentel des boutons soit r duit Tenir les commandes de l automatisme tableau t l commande etc hors de port e des enfants Les commandes doivent tre plac es une hauteur minimum de 1 5 m du sol et hors du rayon d action des parties mobiles Avant l ex cution de toute op ration d installation de r glage d entretien de l installation couper le courant en agissant sur l interrupteur magn tothermique cet effet branch en amont de l installation LA SOCIETE RIB N ACCEPTE AUCUNE RESPONSABILITE pour d ventuels dommages provoqu s par la non observation dans l installation des normes de s curit et des lois actu ellement en vigueur CONSERVER SOIGNEUSEMENT CES INSTRUCTIONS 15 Pu 3 4 N B Si la centrale lectrique ne dispose d aucun interrupteur il faut en installer un de type magn tothermique en amont de cette derni re omnipolaire avec ouverture minimale des contacts corr
29. A PROCEDURA CONTROLLO SENSO DI ROTAZIONE DEL MOTORE E RIPETERE LA PROGRAMMAZIONE SOPRA DESCRITTA E PROGRAMMAZIONE CODICI RADIO APERTURA TOTALE 30 CODICI MAX SOLO MODELLI CRX La programmazione pu essere eseguita solo a cancello fermo de PIE 3 4 5 6 7 Posizionare DIP 1 su ON e successivamente il DIP 2 su ON led rosso DL1 di programmazione lampeggia con frequenza di 1 sec ON e 1 sec OFF per 10 secondi Premere il tasto del telecomando normalmente il canale A entro i 10 secondi impostati Se il telecomando viene correttamente memorizzato il led DL2 verde emette un ampeggio tempo di programmazione dei codici si rinnova automaticamente per poter memorizzare il telecomando successivo Per terminare la programmazione lasciare trascorrere 10 sec oppure premere per un attimo il pulsante PROG Il led rosso DL1 di programmazione smette di lampeggiare Riposizionare DIP 1 su OFF e DIP 2 su OFF Fine procedura PROCEDURA CANCELLAZIONE DI TUTTI I CODICI RADIO DEDICATI ALL APERTURA TOTALE La cancellazione pu essere eseguita solo a cancello fermo die ie 4 5 6 Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON led rosso DL1 di programmazione lampeggia con frequenza di 1 sec ON e 1 sec OFF per 10 secondi Premere e mantenere premuto il pulsante PROG per 5 secondi La cancellazione della memoria viene segnalata da due lampeggi del led verde DL2 ll led rosso D
30. CRO TRANSMITTER TX SLIM SYNCRO code ACG8029 for more than 2 photocells couples up to 4 TOUCH MECHANICAL STRIP L 2 m CERTIFIED EN 13849 2 2008 CATEGORY 3 code ACG3015 PROBE 4 The probe detects the motor temperature to operate the heating system under low code ACG4665 temperature conditions up to 30 C connect to connector J8 NYLON RACK MODULE 4 with zinc plated angle Iron In 1 m bars Ideal for gates up to 1 000 kg 2 200 Ibs weight 1m 3 28 code ACS9000 10 m 32 8 1 m 3 28 x 10 code ACS9001 FIT SYNCRO FIT SYNCRO PHOTOCELLS for the wall installation code ACG8026 The range you can set is 10 20 m 30 60 ft You can fit many couples close together thanks to the synchronising circuit Add the SYNCRO TRANSMITTER code ACG8028 for more than 2 photocells couples up to 4 COUPLE OF BUILT IN BOXES FOR THE FIT SYNCRO code ACG8051 RADIO TRANSMITTER SUN a a SUN 2CH code ACG6052 SUN 4CH code ACG6054 SUN CLONE 2CH code ACG6056 SUN CLONE 4CH code ACG6058 Wi Fi DEVICES MASTER Wi Fi VERTIGO Wi Fi TOUCH Wi Fi RECEIVER CARD TO MANAGE WIRELESS SYSTEM with connector 12 30V ac dc code ACG6094 with terminal block 12 30 ac dc code ACG6099 NOVA Wi Fi P WIRELESS PHOTOCELLS SUBSTITUTING SAFETY STRIP WITHOUT WIRES THE SAFETY STRIP code ACG3016 VERTIGO Wi Fi 8 code ACG8042 VERTIGO Wi Fi 10 code ACG8043 PHOTOCELLS WITHOUT WIRES code ACG8037 RED RADIO TRANSMITTER PAIR OF COLUMS NOVA code
31. D D D P8 Geschwindigkeitsabnahme OFF aktiviert P9 Gradueller Start ON aktiviert P 10 Bef higung f r TEST berwachung Rippe ON bef higt OFF nicht bef higt P11 ON e Weil O QE P e E 8 8 e e 5 Gdo RI TRIMMER Nur am Ende der Bewegung beim ffnen und schlieBen des LOW SPEED Tores R2 TRIMMER Elektronischer Regler f r die Motorenst rke TORQUE DIP 12 OFF 1 gt PROG Druckschalter zur Programmierung TORQUE ELEKTRONISCHER KRAFTREGULATOR Die Kraftregulierung erfolgt durch Drehen des Trimmers TORQUE der die Ausgangsspannung an die Motorleiter das Drehen im Uhrzeigersinn verst rkt die Motorkraft Diese Kraft setzt nach 3 Sekunden ab Beginn jedes Man vers automatisch ein Dies gibt dem Motor die maximale Anlaufkraft ZU BEACHTEN WENN DIESER TRIMMER NACH PROGRAMMIERUNGSPROZEDUR REGULIERT WIRD KANN DIE IMPOSTIERTE MESSEINHEIT F R DEN ANFANG DER GESCHWINDIGKEITSABNAHME VARIIEREN IN MEHR ODER IN WENIGER GEGEN BER DER IMPOSTIERTEN WIRD ALSO EINE ERNEUTE REGULIERUNG DES TRIMMERS VORGENOMMEN IST ES VON VORTEIL DIE PROGRAMMIERUNG NEU EINZUSTELLEN LANGSAME GESCHWINDIGKEIT Geschwindigkeitsregler Wenn der DIP 8 in Position OFF steht richtet sich die Geschwin
32. DE GESTION SYST ME SANS FILS embrochable 12 30V ac dc code ACG6094 avec bornes visser 12 30V ac dc code ACG6099 NOVA Wi Fi z PHOTOCELLULES SANS FIL POUR BARRE PALPEUSE SANS FILS REMPLACER LA BARRE PALPEUSE code ACG3016 VERTIGO Wi Fi 8 code ACG8042 VERTIGO Wi Fi 10 code ACG8043 TRANSMETTEUR RADIO RED PHOTOCELLULES SANS FILS code ACG8037 PAIRE DE POTEAUX NOVA code ACG8039 CLAVIER NUM RIQUE RADIO pour barre palpeuse m canique ou lectrique alimenter par 3 piles de type AA de 1 5V non comprise RED permet la r alisation d une installation avec barres palpeuses fix es galement sur le battant en mouvement sans l adoption de syst mes d assemblage de c bles encastrable code ACG9434 II est conforme la norme EN13849 1 2007 et associ un tableau lectronique RIB il mural code ACG9436 est un dispositif de protection de Classe 2 code ACG6202 BLOCK Wi Fi SPARK Wi Fi S LECTEUR CL SANS FILS code ACG6098 FEU CLIGNOTANT SANS FILS code ACG7064 SUPPORT LATERAL code ACG7042 24 SYSTEM LAY OUT obt Glo xy 1 K500 operating device 2 External photocells 3 Rack of Module 4 4 Key selector 5 Radio antenna 6 Blinker 7 Limit switch plate cams 8 Mechanical strip 9 Pneumatic strip or Fotocosta 10 Internal Photocells 11 Photocell columns 12 Mechanical stops TECHNICAL FEATURES Irreversible operating devices for sliding gates with a maximum weight of
33. DOTES D UNE ALIMENTATION DE CONTROLE PROPRE UN CORDON MECANIQUE NE PEUT ETRE MONITORE DONC LE DIP 10 DOIT ETRE POSITIONNE SUR OFF ALARME D AUTOTEST BARRE PALPEUSE DIP 10 ON En fin d ouverture si le monitorage du cordon a un r sultat n gatif une alarme intervient qui est visualis e par le clignotant qui reste allum et par le buzzer si raccord actif pendant 5 minutes la fermeture du portail n est pas permise dans cette condition et il n est possible de relancer le fonctionnement normal qu en r parant le cordon et en appuyant sur une des commandes habilit es POUSSOIR DE STOP peut tre branch en s rie avec le commun de fin de course Ce branchement est conseill quand la modalit de fonctionnement automatique est utilis e DIP 6 OFF Durant toute op ration le bouton de STOP ex cute l arr t du portail TRAVAIL AVEC HOMME PRESENT DANS LE CAS DE PANNE DE S CURIT Sile cordon est en panne ou engag pour plus de 5 secondes ou si la cellule photo lectrique est en panne ou engag e pour plus de 60 secondes les commandes K BOUTON et PIETONS fonctionnent seulement homme present La signalisation de l activation de cette op ration est donn e par la LED de programmation qui clignote Avec cette op ration est autoris e l ouverture ou fermeture seulement en appuyant sur les boutons de contr le Le contr le radio et la fermeture automatique sont exclues parce que leur fonctionnement n est pas autoris par l
34. E Cicli normativi n 12 30s 2s 10 30s 2s 3 Cicli consigliati al giorno n 300 y f Y 5 Servizio 60 n d N Cicli consecutivi garantiti n 25 5m g MP gt Maki Zu orf d ZC 2 pa N 7 Lubrificazione a grasso COMLUBE LHITGREASE EP GR 2 2571 1 I l S LL bad L LZ n Peso max kg 8 L 274 1 245 Rumorosit db lt 70 Temperatura di lavoro 10 55 Grado di protezione IP 54 Misure in mm inch 5 INSTALLAZIONE K500 CONTROLLO PRE INSTALLAZIONE IL CANCELLO DEVE MUOVERSI SENZA ATTRITI N B obbligatorio uniformare le caratteristiche del cancello alle norme e leggi vigenti 50 min Il cancello pu essere automatizzato solo se in buono stato e se rispondente alla norma EN 12604 L anta non deve presentare porte pedonali In caso contrario occorrer prendere z opportune precauzioni in accordo al punto 5 4 1 della EN12453 ad esempio impedire Ba EF il movimento del motore quando il portoncino aperto grazie ad un microinterruttore opportunamente collegato in centralina K Non bisogna generare punti di intrappolamento ad esempio tra anta aperta del cancello K500 e cancellata Oltre ai finecorsa presenti nell unit necessario che a ciascuna delle due posizioni estreme della corsa sia presente un fermo meccanico fisso che arresti il cancello nel caso di malfunzionamento dei finecorsa A tal fine il fermo meccanico deve essere dimensionato per sopportare la spinta stati
35. EN 12445 point 7 3 2 1 example column height 2 2m gt 6 copies of photocells 3 internal and 3 external better if complete of syncronism feature FIT SYNCRO with TX SYNCRO The system must be grounded Data described by this manual are only Indicative and RIB reserves to modify them at any time Install the system complying with current standards and regulations Sicherheitsnormen entsprechen nicht eingehalten werden INSTALLATIONSVORSCHRIFTEN BEACHTET WERDEN 1 Wenn nicht bereits an der elektrischen Schaltzentrale vorgesehen muss vor der Schaltzentrale ein thermomagnetischer Schalter i nstalliert werden omnipolar mit einer minimalen Kontakt ffnung von 3 mm der ein von den internationalen ormen anerkanntes Konformit tszeichen besitzt Vandalismus geschuetzt werden z B mit einen Panzergehaeuse 2 RIB empfiehlt den Kabeltyp HOSRN F mit einem 1 5mm generell sollten die Normative IEC 364 Solch ein Geraet muss vor Schluesselkatsten in einem minimalen Querschnitt von und alle anderen geltenden ontagenormen des Bestimmungslandes eingehalten werden 3 Position des ersten paar Fotozellen Der sollten nicht hoeher als 70cm vom Boden sein und sollte nicht mehr als 20 cm entfernt von del gilt fuer Schiebe und Drehtore In bereinstimmung 4 n Einklang mit der Norm EN12453 ist es bei Tor und innerlich das ganzes Rennen des mobil Teils j H he der Spalte des Gatters b
36. F pendant 10 secondes 3 Appuyer et maintenir le bouton PROG enfonc pendant 5 secondes L annulation de la m moire est signal e par deux clignotements de la led verte DL2 4 Laled rouge DL1 de programmation reste active et il est possible d ins rer de nouveaux codes comme dans la proc dure d crite ci dessus 5 Replacer DIP 1 sur OFF et DIP 3 sur OFF 1 4 20 6 Fin de proc dure SIGNALISATION MEMOIRE SATUREE CODES RADIO PREVUS POUR L OUVERTURE PIETONNIERE La signalisation peut s obtenir uniquement avec le portail ferm 1 Positionner DIP 1 sur ON et ensuite le DIP 3 sur ON 2 La led verte DL2 clignote pendant 6 fois en signalant la m moire satur e 30 codes pr sentes 3 Ensuite la led DL1 de programmation reste active pendant 10 secondes en permettant une ventuelle annulation totale des codes 4 Replacer DIP 1 sur OFF et DIP 3 sur OFF 5 Fin de proc dure FONCTIONNEMENT DES ACCESSOIRES DE COMMANDE ATTENTION CONNECTER LES ACCESSOIRES A COMANDE SEULEMENT SI IMPULSIVE Faire attention que des autres accessoires pour le commande p e senseurs magn tique sont programm e avec modalit IMPULSIVE ou contraire le mouvement est sans s curit POUSSOIR DE COMMANDE COM K BUTTON Si le DIP6 est sur ON gt Il effectue une commande cyclique des commandes ouvre stop ferme stop ouvre etc Si le DIP6 est sur OFF gt Il effectue l ouverture lorsque le p
37. FF Den entsprechenden Kontakt in Ordnung bringen oder ersetzen Impuls K ist immer angeschlossen Kontrollieren und ersetzen Sie eventuelle Tasten oder Mikro Schalter des W hlers Vergewissern dass DIP 8 auf der Position OFF steht Verlangsamen bef higt Die Aufnahme der Zeiten mittels der Prozedur von DIP 2 ausf hren Regulierung Trimmer LOW SPEED kontrollieren 42 OPTIONEN F r die Anschl sse und die technischen Daten der Zubeh re verweisen wir auf die entsprechenden Betriebsanleitungen EINZUZEMENTIERENDE PLATTE Kode ACG8108 FIT SLIM WANDFOTOZELLEN Kode ACG8032 EIN PAAR FOTOZELLEN STAENDER F R FIT SLIM Kode ACG8065 FIT SLIM Fotozellen haben Synchronismusfunktion im Wechselstrom Strom und Strecken 20m Dank einer Synchronisiereinrichtung sind mehrere sich gegenseitig ann hernde Paare m glich Bei mehr als 2 Fotozellenpaare bis 4 den SENDER SYNCRO TX SLIM SYNCRO Kode ACG8029 TOUCH MECHANISCHE KONTAKTLEISTE L NGE 2 m EN 13849 2 2008 ZERTIFIZIERT KATEGORIE 3 Kode ACG3015 PROBE 4 Temperaturmess Sonde f r den Motor und geeignete Motorentemperatur und deren Aufheizung Dies fiir besonders kalte und harte Temperaturen bis zu 30 C Anschluss an Verbinder J8 Kode ACG4665 NYLON ZAHNRAD MOD 4 mit verzinkter Ecke als Stange zu 1m Ideal f r Tore bis zu einem Gewicht von 1000 kg 1m Kode ACS9000 10m 1 10 Kode ACS9001 FIT SYNCRO WANDFOTOZELLEN FITSYNCRO Kode ACG8026 ein
38. IMENTER code ACG8108 FIT SLIM PHOTOCELLULES MURALES code ACG8032 PAIRE DE POTEAUX P0UR FIT SLIM code ACG8065 Les photocellules FIT SLIM ont la fonction de synchronisme dans le courant C A et les gammes de 20m Plusieurs paires sont appliqu s rapproch s les uns des autres gr ce au circuit synchronis Ajouter le TRANSMETTEUR TX SLIM SYNCRO s il existe plus de deux paires de photocellules jusqu 4 code ACG8029 TOUCH BARRE PALPEUSE M CANIQUE L 2 m CERTIFI E EN 13849 2 2008 CAT GORIE 3 code ACG3015 PROBE 4 Sonde de relev temp rature moteur pour r chauffement de celui ci en climats particuli rement froids jusqu 30 C brancher connecteur J8 code ACG4665 CR MAILL RE MOD 4 EN NYLON avec angulaire galvanis en barres de 1m Id al pour les portails pesant jusqu 1000 kg 1m code ACS9000 10 m 1 10 code ACS9001 FIT SYNCRO PHOTOCELLULES MURALES FITSYNCRO code ACG8026 Port e cloisonnable 10 20 m Plusieurs couples sont appliqu s rapproch s les uns des autres gr ce au circuit synchronis Ajouter le TRANSMETTEUR SYNCRO code ACG8028 S il existe plus de deux couples de photocellules jusqu 4 COUPLE DE COFFRETS ENCASTRABLES POUR FITSYNCRO code ACG8051 EMETTEUR RADIO SUN lt a SUN 2CH code ACG6052 SUN 4CH SUN CLONE 2CH code ACG6056 code ACG6054 SUN CLONE 4CH code ACG6058 DISPOSITIFS Wi Fi MASTER Wi Fi VERTIGO Wi Fi TOUCH Wi Fi FICHE
39. IP 9 ON ogni volta che viene comandato il cancello viene eseguita di default una partenza graduale pari a 1 secondo SEGNALAZIONI LED DL1 Rosso Programmazione attivata DL2 Verde Programmazione radio attivata solo nei modelli CRX DL3 Rosso Contatto finecorsa di apertura NC DL4 Rosso Contatto finecorsa di chiusura DL5 Rosso Cancello in chiusura DL6 Verde Cancello in apertura DL7 Rosso Contatto fotocellule NC DL8 Rosso Contatto coste NC DL9 Rosso Contatto comando pedonale NO C CONTROLLO SENSO DI ROTAZIONE DEL MOTORE Questo controllo ha il compito di agevolare l installatore durante la messa in opera dell impianto o per eventuali controlli successivi y 2 3 4 5 6 7 Sbloccare l operatore tramite lo sblocco manuale e posizionare le di finecorsa Portare il cancello a met corsa e bloccare l operatore Mettere il DIP1 in posizione ON gt il led DL1 inizia a lampeggiare Premere e mantenere premuto il pulsante PROG il movimento eseguito ad uomo presente apre stop chiude stop apre etc gt il LED VERDE DL6 OPEN si accende e il cancello deve aprire nel caso contrario rilasciare il pulsante PROG e invertire i fili del motore V e W e fermarsi in seguito al contatto con il finecorsa elettrico se questo non succede rilasciare il pulsante PROG ed invertire i due fili del finecorsa LSO e LSC Premere
40. K 230Vac 50 Hz 230Vac 40W PIETON BUZZER COMMUN PAS APAS BARRE PALPEUSE x PHOTOCELLULES gt 24Vdc 0 4A 15 24Vdc 0 4A 15 ACCESSOIRES gt 7 AUTOTEST POUR BARRE PALPEUSE gt PAS A PAS PIETON SELECTEURS A CLEF BLOCK ET INTERRUPTEUR FLAT PHOTOCELLULES FIT SLIM BARRE PALPEUSE DE SECURITE MECANIQUE 18 A BRANCHEMENTS Ji Kerg no NE TOUCHEZ PAS LE PONTET S IL EST ENLEV L OP RATEUR NE SE D PLACE PAS J2 AERIAL Antenne radio LSC Contact de fin de course servant arr ter la fermeture LSO Contact de fin de course servant arr ter l ouverture COM Commun des contacts PED BUTT Contact commande pi tonne J3 L N Alimentation 230 Vac 50 60 Hz sur demande 120 60 2 J4 mm Branchement des conducteurs de terre Obligatoire TERRE J5 RADIO Connecteur pour radior cepteur ext rieur 24Vdc mod les pas CRX Module radio incorpor mod les CRX J6 A TEST Positif pour alimentation autotest barre palpeuse 24Vdc A Positif Alimentation accessoires 24Vdc A N gatif pour alimentation accessoires 24Vdc COM Commun des contacts POSITIF K BUTT Contact impulsion simple NO PHOT Contact photocellules NF EDGE Contact des barres palpeuses devant intervenir en phase d ouverture et de fermeture NF ah Buzzer Branchement avertisseur sonore 24Vdc max 200 mA N GATIF J7 G Feu clignotant max 40W
41. K2007 mit Firmware 12 NOUP fragen WARNUNG EINE UHR AN DEM K2007 mit fw 05 oder mehr verbunden UMFASST DIE BEWEGUNG DES AUTOMATISCHEN TORS OHNE SICHERHEIT AKTIV Diese Funktion ist in den Spitzenzeiten n tzlich wenn der Fahrzeugverkehr sich verlangsamt z B Schichtwechsel Notfall im Wohn oder Parkplatzbereich und tempor r bei Umz gen FUNKTION UHR ANBRINGUNGSART Anfragen Sie K2007 mit Firmware 12 NOUP W hlen Sie die Automatik Betrieb DIP 6 OFF Durch die Verbindung an einen Schalter und oder an eine Uhr des Typs Tag Woche anstelle oder parallel des normalerweise ge ffneten ffnungsschalters N G COM K BUTTON ist es m glich die Automation zu ffnen und solange offen zu halten bis der Schalter gedr ckt wird oder die Uhr aktiv ist Bei offener Automation sind alle Steuerfunktionen untersagt Beim Loslassen des Schalters oder beim Ablauf der eingegebenen Zeit erl scht die Automatisierung immediat SCHALTTASTE FFNUNG F R FUSSG NGER COM PED BUTTON Bestimmt ist dieser Steuerbefehl f r eine partielle ffnung und die darauf folgende Schlie ung Mittels DIP6 kann die Funktionierungsmodalit t der Steuertaste f r Fu g nger ausgew hlt werden Steht DIP6 auf ON gt Einen zyklischen Befehl aus ben ffne stopp schlieBe stopp usw Steht DIP6 auf OFF gt Die ffnungbeigeschlossenemTorausf hren Wennw hrend der ffnungsbewegung in Betrieb gesetzt bleibt die Wirkung aus Wenn bei offenem To
42. K500 Con funzionamento a uomo presente se le fotocellule o le coste sono guaste Avec travail avec homme present dans le cas de panne de s curit With functioning in dead man mode when the safety devices are failing Mit arbeit im mannsbeisein im fall eines ausfalls der Sicherheiten Con funcionamiento a hombre presente en caso de aver as con los accesorios de seguridad C Operatore Alimentazione Con quadro Peso max cancello Spinta max Coppia max Codice Operateur Alimentation Avec coffret Poids maxi portail Pouss e maxi Couple maxi Code Operator Power Supply With control board Max gate weight Max Thrust Max torque Code Torantrieb Stromspannung Mit Steuerung Max Torgewicht Max Schubkraft Max Drehmoment Code Operador Alimentacion Con panel electronico Peso m x verja Max Empuje Coppia max Codigo AA33694 230V 50 60Hz K2007 CRX 400 N 9 5 Nm AA33695 K500 K2007 Wi Fi 500 kg 1103 Ibs AA33753W AA33693 120V 60Hz 500 N 12Nm K2007 AA33696 ITALIANO pag 05 FRANCAIS pag 15 ENGLISH page 25 DEUTSCH pag 35 ESPA OL pag 45 ISTRUZIONI DI SICUREZZA IMPORTANTI PER L INSTALLAZIONE ATTENZIONE PER LA SICUREZZA DELLE PERSONE IMPORTANTE CHE VENGANO SEGUITE TUTTE LE ISTRUZIONI SEGUIRE TUTTE LE ISTRUZIONI DI INSTALLAZIONE 1 Questo libretto d istruzioni rivolto esclusivamente a del personale specializzato che sia a conoscenza dei criteri costruttivi e dei dispositivi di protezione contro gli infort
43. L SENTIDO DE ROTACI N DEL MOTOR ON PUNTO C DIP 2 PROGRAMACI N TIEMPOS ON PUNTO D DIP 2 1 PROGRAMACI N TEMPI ABERTURA PEATONAL DIP 2 ON SEGUIDO POR DIP 1 ON PUNTO D DIP 1 2 MEMORIZACI N CANCELACI N C DIGOS DE RADIO MANDO APERTURA TOTAL DIP 1 ON seguido de DIP 2 ON PUNTO E S LO PARA MODELOS CRX DIP 1 3 MEMORIZACI N CANCELACI N C DIGOS DE RADIO MANDO APERTURA PEATONAL DIP 1 ON seguido de DIP 3 ON PUNTO F S LO PARA MODELOS CRX MICROINTERRUPTORES DE GESTI N DIP 3 Tiempo de espera antes del cierre autom tico ON DIP 4 Fotoc lulas Interrumpen la abertura y el cierre OFF Fotoc lulas Interrumpen s lo el cierre ON DIP5 Prelampeggio ON Lampeggio normale OFF DIP 6 Mando de impulso nico K BUTT y RADIO paso a paso ON autom tico OFF DP 7 Freno electr nico ON activado DP 8 Deceleracion OFF activada DIP 9 Arranque gradual ON activado D D D s P10 Habilitaci n TEST monitorizaci n costa ON habilitado OFF deshabilitado P11 ON P12 OFF 1 gt Bot n para la programaci n PROG EDO C o e 0 scale m las R1 TRIMMER Regulaci n de la velocidad de deceleraci n tanto en apertura LOW SPEED como en el cierre R2 TRIMMER Regulador elec
44. L1 di programmazione rimane attivo ed possibile inserire nuovi codici come da procedure sopra descritte Riposizionare DIP 1 su OFF e DIP 2 su OFF Fine procedura SEGNALAZIONE MEMORIA SATURA CODICI RADIO DEDICATI ALL APERTURA TOTALE La segnalazione si pu ottenere solo a cancello fermo Fa 3 4 5 F Posizionare il DIP 1 su ON e successivamente il DIP 2 su ON Il led verde DL2 lampeggia per 6 volte segnalando memoria satura 30 codici presenti Successivamente il led DL1 di programmazione rimane attivo per 10 secondi consentendo un eventuale cancellazione totale dei codici Riposizionare DIP 1 su OFF e DIP 2 su OFF Fine procedura PROGRAMMAZIONE CODICI RADIO APERTURA PEDONALE 30 CODICI MAX SOLO MODELLI CRX La programmazione pu essere eseguita solo a cancello fermo i de 3 4 5 6 Ze Posizionare DIP 1 su ON e successivamente il DIP 3 su ON led rosso DL1 di programmazione lampeggia con frequenza di 1 sec ON e 1 sec OFF per 10 secondi Premere il tasto del telecomando normalmente il canale B entro i 10 secondi impostati Se il telecomando viene correttamente memorizzato il led DL2 verde emette un ampeggio tempo di programmazione dei codici si rinnova automaticamente per poter memorizzare il telecomando successivo Per terminare la programmazione lasciare trascorrere 10 sec oppure premere per un attimo il pulsante PROG Il led rosso DL1 di programmazione smette di lam
45. LAT FOTOC LULAS FIT SLIM COSTA MEC NICA 46 A CONEXI N Ji NO TOCAR EL PUENTE SI SE REMUEVE EL MOTOR co FUNCIONA J2 AERIAL Antena de radio LSC Contacto tope de recorrido que para el cierre del motor LSO Contacto tope de recorrido que para la abertura del motor COM Com n de los contactos PED BUTT Contacto mando peatonal J3 L N Alimentaci n 230Vac 50 60Hzh 120V 60Hz bajo requesta J4 TIERRA Conexi n de los conductores de tierra Obligatorio J5 RADIO Conector para radio receptor externo 24Vdc modelos no CRX Modulo radio incorporado modelos CRX J6 A TEST Positivo para alimentaci n autotest costa a 24Vdc A Positivo Alimentaci n accesorios a 24Vdc A Negativo para alimentaci n accesorios a 24Vdc COM Com n de los contactosi POSITIVO K BUTT Contacto impulso nico NA PHOT Contacto fotoc lulas NC EDGE Contactos costas en cierre y abertura NC lt Buzzer Indicador ac stico 24Vdc max 200 mA NEGATIVO J7 Intermitente max 40W U MOTOR Conexi n com n motor V W MOTOR Conexi n inversores y condensador motor J8 PROBE Conector para sondas de calefacci n C d ACG4665 opcional RELE Y MANDO MOTOR K1 gt mando relampagueante K2 gt mando en direcci n de cierre K3 gt mando en direcci n de abertura Q1 gt TRIAC mando motor en abertura y cierre x ON B ADAPTACION MICROINTERUPTOR PARA PROCEDER 1 DIP 1 CONTROL DE
46. LE OFFNUNG ACHTUNG Wenn die Eing nge PHOT und EDGE nicht angeschlossen sind berbr ckung zwischen COM PHOT und COM EDGE ausf hren und zwar vor der Programmierungsprozedur Die Programmierung kann unabh ngig von der aktuellen Position des Tors ausgef hrt werden 1 Stellen Sie den Mikroschalter 2 auf die Position ON gt Die LED DL1 sendet kurze Blinkintervalle 2 Bet tigen Sie die Taste PROG Das Tor schlieBt sich 2 Sekunden nach dem SchlieBen ffnet sich das Tor von allein Nach vollendeter ffnung bleibt es stehen Warten Sie die von Ihnen gew nschte ffnungszeit des Tors ab auszuschlie en mit DIP3 OFF 3 Bet tigen Sie die Taste PROG Dadurch schlieBen Sie das Tor auch die Z hlung der Wartezeit bis zum automatischen SchlieBen wird angehalten max 5 Minuten 4 Ist der Endlauf f r die Schlie ung erreicht h lt das Tor an 5 STELLEN SIE DEN DIP 2 NACH DER PROGRAMMIERUNG WIEDER AUF OFF ZU BEACHTEN Die Geschwindigkeitsabnahme wird von der Steuerstation mit der Zeitenprogrammierung automatisch bestimmt und aktiviert sich bei zirka 50 60 cm vor Erreichung des Endlaufs f r die ffnung oder Schlie ung Diese Angaben k nnen jedoch je nach Temperatur leicht variieren D ZEITENPROGRAMMIERUNG FURDIE FUSSGANGER FFNUNG 8 Bei geschlossenem Tor 1 Erst DIP2 auf ON stellen Led DL1 blinkt in schneller Sequenz dann DIP1 auf ON stellen Led DL1 blinkt in langsamer Sequenz 2 Die Schalttast
47. MPLETE OPENING You can only check the memory if the gate is closed 1 Position DIP 1 to ON and then DIP 3 to ON 2 The green DL2 LED will flash 6 times if the memory is full 30 codes have been stored 3 After this the DL1 programming LED will remain active for 10 seconds so that you can delete all codes if required 4 Reposition DIP 1 to OFF and DIP 3 to OFF 5 You have completed the procedure FUNCTIONING OF CONTROL ACCESSORIES ATTENTION ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED Make sure that any other type of command accessories e g mass detectors used on the installation are set in the IMPULSIVE mode otherwise the gate will be operated even without the protection of the safety devices STEP BY STEP or AUTOMATIC commands K BUTT button PED BUTT button RADIO REMOTE button DIP 6 ON The K BUTT the PED BUTT button the RADIO REMOTE buttons perform the Cyclic command open stop close open stop etc DIP 6 OFF The K BUTT the PED BUTT button the RADIO REMOTE buttons perform the open command if pressed with the gate completely closed the close command if pressed with the gate completely opened no effect if pressed during the gate opening the gate re open if pressed while the gate is closing The K BUTT opens the gate completely whereas the PED BUTT opens the gate partially as described in Point D CLOCK FUNCTION If you want the Clock Function must request K2007 wit
48. N 2CH c d ACG6052 SUN 4CH c d ACG6054 SUN CLONE 2CH c d ACG6056 SUN CLONE ACH c d ACG6058 DISPOSITIVOS Wi Fi MASTER Wi Fi FICHA DE GESTI N SISTEMA SIN CABLES con enchufe 12 30 ac dc con regleta 12 30 ac dc c d ACG6094 c d ACG6099 NOVA Wi Fi FOTOC LULAS SIN CABLES PAR DE COLUMNAS NOVA c d ACG8037 c d ACG8039 TECLADO DIGITAL V A RADIO empotrado c d ACG9434 de pared c d ACG9436 BLOCK Wi Fi ELECTOR DE LLAVE SIN CABLES c d ACG6098 VERTIGO Wi Fi TOUCH Wi Fi FOTOC LULAS SIN CABLES PARA REEMPLAZAR A LA COSTA COSTA SIN CABLES c d ACG3016 c d ACG8042 c d ACG8043 VERTIGO Wi Fi 8 VERTIGO Wi Fi 10 TRANSMISOR RADIO RED para costa mec nica o el ctrica Alimentar con 3 pilas estilo tipo AA de 1 5V no incluidas RED permite realizar una instalaci n con costas colocadas incluso sobre la hoja en movimiento sin la adopci n de sistemas recoge cables Conforme a la norma EN13849 1 2007 Unido a un cuadro electr nico RIB es un dispositivo de protecci n de Clase 2 c d ACG6202 SPARK Wi Fi a cod ACG7064 c d ACG7042 INTERMITENTE SIN CABLES SOPORTE LATERAL O RIB Srl AZIENDA CON SISTEMA 25014 Castenedolo Brescia Italy DI QUALIT CERTIFICATO Via Matteotti 162 DA DNV Tel 39 030 2135811 Fax 39 030 21358279 21358278 COMPANY WITH QUALITY www ribind it ribind ribind it SYSTEM CERTIFIED automatismi per cancelli BY DNV auto
49. NDO SOLO SE IMPULSIVI Assicurarsi che eventuali altri tipi di accessori di comando per esempio sensori magnetici siano programmati nella modalit IMPULSIVA altrimenti attiverebbero la movimentazione del cancello senza sicurezze attive PULSANTE DI COMANDO COM K BUTTON Se DIP6 su ON gt Esegue un comando ciclico dei comandi apre stop chiude stop apre ecc Se DIP6 su OFF gt Esegue l apertura a cancello chiuso Se azionato durante il movimento di apertura non ha effetto Se azionato a cancello aperto lo chiude e durante la chiusura se azionato lo fa riaprire FUNZIONE OROLOGIO Se desiderate la funzione orologio dovete richiedere K2007 con firmware 12 NOUP ATTENZIONE UN OROLOGIO COLLEGATO AL K2007 con fw 05 o superiore COMPORTA IL MOVIMENTO AUTOMATICO DEL CANCELLO SENZA SICUREZZE ATTIVE La funzione orologio utile nelle ore di punta quando il traffico veicolare risulta rallentato es entrata uscita operai emergenze in zone residenziali o parcheggi e temporaneamente per traslochi MODALIT DI APPLICAZIONE FUNZIONE OROLOGIO Richiedere K2007 con firmware 12 NOUP Selezionare il funzionamento automatico DIP 6 OFF Collegando un interruttore e o un orologio di tipo giornaliero settimanale al posto o in parallelo al pulsante di comando n a COM K BUTTON possibile aprire e mantenere aperta l automazione finch l interruttore viene premuto o l orologio rimane attivo Ad automazione aperta ve
50. NGEN ACG7059 mit Lampen von max 40W versorgen FUNKTION VORBLINKEN DIP5 auf OFF gt Motor Blinker und Buzzer starten gleichzeitig DIP5 auf ON gt Blinker und Buzzer starten 3 Sekunden vor dem Motor BUZZER Opzional COM BUZZER Stromzufuhr f r Buzzer Funktion 200mA zu 24Vdc W hrend der ffnung und der Schlie ung gibt der Buzzer ein akustisches Wechselsignal Falls Sicherheitsvorrichtungen Alarme ausgel st sind wird die Frequenz der Signalschwankung erh ht KONTROLLAMPE F R DIE SIGNALISIERUNG TOR OFFEN A negativo LSC Diese Kontrolllampe ist daf r zust ndig die Position des offenen Tores zu signalisieren dies wenn dieses nur teilweise ge ffnet ist oder auch wenn nicht vollst ndig geschlossen Nur wenn das Tor v llig geschlossen ist erl scht diese Kontrolllampe N B in Serie mit Kontrollicht einen 2K2 widerstand zu verbinden Auch durch Kontrollampe wird die Logik der Zentrale in Frage gestellt mit der M glichkeit dass Operationen gestoppt werden TECHNISCHE EIGENSCHAFTEN Feuchtigkeit Versorgungsspannung lt 95 ohne Kondensierung 230V 10 auf Antrag 120V 10 FEHLER Frequenz 50 60Hz Netzmikroschalter 20ms Max am Ausgang des Motors verwaltbare Leistungskraft 16V Max Belastbarkeit am Ausgang des Blinkers 40W mit Widerstandsbelastung Max Stromaufnahme der Karte ausschlie lich des Zubeh rs 33mA Verf gbarer Strom f r die Fotozellen 0 4 15 24VGS Schutzgrad IP54 Gewi
51. OFF gt Efect a la abertura con la verja cerrada Si se acciona durante el movimiento de abertura no tiene ning n efecto Si se acciona con la verja abierta la cierra y durante el movimiento de cierre si se acciona la vuelve a abrir CIERRE AUTOM TICO CON ABERTURA TOTAL Los tiempos de pausa antes del cierre autom tico en apertura total de la verja se regulan durante la programaci n de los tiempos El tiempo m ximo es de 5 minutos en modalidad de apertura total Los tiempos de pausa son activables o desactivables a trav s del DIP3 ON activo CIERRE AUTOM TICO CON ABERTURA PEATONAL Los tiempos de pausa antes de que se produzca el cierre autom tico peatonal de la cancela se registran durante la programaci n peatonal El tiempo de pausa m ximo es de 5 minutos El tiempo de pausa es activable o desactivable a trav s del DIP3 ON activo FUNCIONAMIENTO DE LOS ACCESORIOS DE SEGURIDAD FOTOCELULA COM PHOT DIP 4 OFF gt Si se interpone un obst culo entre el rayo de las fotoc lulas con la verja cerrada sta no se abre Durante el funcionamiento las fotoc lulas intervienen tanto en la fase de abertura restableciendo el movimiento de apertura s lo despu s de que las fotoc lulas se liberan como en la fase de cierre restableciendo el movimiento inverso s lo despu s de que las fotoc lulas se liberan DIP 4 ON gt Si se interpone un obst culo entre el rayo de las fotoc lulas con la verja cerra
52. OUVERT A negativo LSC a la t che de signaler les tats du portail ouvert partiellement ouvert ou de toute fa on non ferm en totalit Il s teint seulement lorsque le portail est compl tement ferm N B relier en s rie voyant une r sistance de 2K2 Si on exc de avec les voyant la logique de la centrale en sera compromise avec un blocage possible des op rations CARACT RISTIQUES TECHNIQUES G N RALES Humidit lt 95 sans condensation Tension d alimentation 230V 10 120V 10 sur demande Fr quence 50 60Hz Micro interrupteurs de r seau 20ms Puissance maximale pouvant tre contr l e la sortie du moteur 1CV DEFAUT Charge maximale la sortie feu clignotant 40W avec charge r sistive Absorption maximale carte accessoires exclus 33mA Courant disponible pour photocellules 0 4A 15 24Vdc Indice de protection IP54 Poids de l appareillage 0 55 kg Encombrement 130 x 50 x 115 mm CARACT RISTIQUES TECHNIQUES RADIO uniquement mod les CRX Fr quence R ception 433 92MHz Imp dance 520 Sensibilit gt 2 24pV Temps d excitation 300ms Temps de d sexcitation 300ms Codes m morisables N 60 30 pour ouverture totale et 30 pour ouverture pietonniere Courant disponible sur le connecteur radio 200mA 24Vdc Toutes les entr es doivent tre util es avec des contacts secs car l alimentation est g n r e l int rieur de la carte et dispos e de facon garantir le respect d une double
53. P 1 auf ON gestellt berpr fen dass sich w hrend der ffnung das gr ne LED DL6 einschaltet und dass bei der Schlie ung das rote LED DL5 aufleuchtet Falls nicht die Klemmen V und W auf der Klemmleiste des Motors vertauschen Zu speichernde Codes L SUNG Nachdem die verschiedenen Verbindungen gelegt sind und Strom angelegt wurde sind alle LEDs ausgeschaltet Der Motor ffnet und schlie t aber hat keine Antriebskraft und bewegt sich langsam Das Tor f hrt die ffnung aus schlie t aber nicht nach der Zeit die eingestellt ist Das Tor ffnet und schlie t beim Bet tigen der verschiedenen K und RADIO Tasten nicht Bei Bet tigung der K Taste f hrt das Tor keinerlei Bewegung aus Die Phase des Verlangsamens wird nicht ausgef hrt Die Integrit t der Schmelzsicherungen F1 und F2 berpr fen Falls die Schmelzsicherung unterbrochen ist nur eine angemessenen Werts benutzen F2 5A F1 100 mA Regulierung der Trimmer TORQUE und LOW SPEED berpr fen Vergewissern dass DIP 3 auf ON gestellt ist Die K BUTTON Taste ist im Automatikbetriebsmodus stets eingeschaltet 6 OFF Taste oder Switch des W hlers ersetzen Autotest Rippe gescheitert gt Verbindungen zwischen Schalttafel und Netzger t der Rippen berpr fen Achtung wenn kein Netzger t f r die Rippen verwendet wird muss DIP 10 auf Position OFF stehen Kontakt Sicherheitsrippe Schaden Kontakt Fotozellen Schaden mit DIP 4 O
54. PER PROCEDURE CONTROLLO SENSO DI ROTAZIONE DEL MOTORE ON PUNTO DIP2 PROGRAMMAZIONE TEMPI ON PUNTO D DIP 2 1 PROGRAMMAZIONE TEMPI APERTURA PEDONALE DIP 2 ON SEGUITO DA DIP 1 ON PUNTO D DIP 1 2 MEMORIZZAZIONE CANCELLAZIONE CODICI RADIO COMANDO APERTURA TOTALE DIP 1 ON seguito da DIP 2 ON PUNTO E SOLO PER MODELLI CRX DIP 1 3 MEMORIZZAZIONE CANCELLAZIONE CODICI RADIO COMANDO APERTURA PEDONALE DIP 1 ON seguito da DIP 3 ON PUNTO F SOLO PER MODELLI CRX MICROINTERRUTTORI DI GESTIONE P3 Tempo di attesa prima della chiusura automatica ON P4 Fotocellule sempre attive OFF Fotocellule attive solo in chiusura ON P5 Prelampeggio ON Lampeggio normale OFF P6 Comando impulso singolo K BUTT e RADIO passo passo ON automatico OFF P7 Freno elettronico ON attivato Rallentamento OFF attivato P9 Partenza graduale ON attivato P 10 Abilitazione TEST monitoraggio costa ON abilitato OFF disabilitato P11 ON P12 OFF ON D D D D D D D D D D e g A CB e E 8 8 e e DE 5 0 soale Ton R1 TRIMMER Regolazione della velocit di rallentamento in apertura e LOW chiusura SPEED R2 TRIMMER Regolatore elettronico della forza del motore TORQUE 1 gt PROG Pulsante per
55. PIETONNE 8 Avec le portail ferm 1 Mettre d abord le DIP2 sur ON le led DL1 clignote rapidement et mettre ensuite le DIP1 sur ON le led DL1 clignote lentement 2 Appuyer sur le bouton pi ton COM PED BUTT le portail s ouvre 3 Appuyer sur le bouton pi ton pour arr ter la course en d finissant ainsi l ouverture du portail 4 Attendre le temps que l on veut qu il reste ouvert peut tre exclu avec le DIP3 sur OFP appuyer alors sur le bouton pi ton pour faire partir la fermeture 5 EN FIN DE PROGRAMMATION PIETONNE REMETTRE LES DIPS 1 ET 2 SUR OFF DURANT LA PROGRAMMATION LES SECURTIES SONT ACTIVES ET LEUR INTERVENTION ARRETE LA PROGRAMMATION LE LED DL1 DE CLIGNOTANT RESTE ALLUME FIXE POUR REPETER LA PROGRAMMATION POSITIONNER LE DIP 2 SUR OFF FERMER LA PORTE SUIVANT LA PROCEDURE CONTROLE SENS DE ROTATION DU MOTEUR ET REPETER LA PROGRAMMATION CI DESSUS DECRITE E PROGRAMMATION CODES RADIO OUVERTURE TOTALE 30 CODES MAX UNIQUEMENT MODELES CRX La programmation peut tre effectu e uniquement avec le portail ferm 1 Positionner DIP 1 sur ON et ensuite le DIP 2 sur ON 2 La led rouge DL1 de programmation clignote avec une fr quence de 1 sec ON et 1 sec OFF pendant 10 secondes 3 Appuyer sur la touche de la t l commande normalement le canal A dans les 10 secondes r gl es Si la t l commande est correctement m moris e la led DL2 verte met un clignotement 4 Le t
56. R J8 PROBE Temperature sensor cable connection PROBE Code ACG4665 optional RELAYS AND MOTOR COMMAND K1 gt Flashing light command K2 gt Closing command gt Opening command 01 gt TRIAC Motor command in opening and closing POINT B settings DIP 1 MOTOR ROTATION DIRECTION CHECK See Point C DIP 2 PROGRAMMING See Point D E DIP 2 1 PROGRAMMING OF THE PEDESTRIAN OPENING See Point D DIP 1 2 STORAGE DELETION OF RADIO CODES FOR COMPLETE OPENING DIP 1 ON followed by DIP 2 ON POINT F ONLY FOR CRX MODELS DIP 1 3 STORAGE DELETION OF RADIO CODES FOR PEDESTRIAN OPENING DIP 1 ON followed by DIP 3 ON POINT G ONLY FOR CRX MODELS OPERATING MODE SETTINGS DIP 3 ON Automatic Closing ENABLED OFF Automatic Closing DISABLED DIP 4 ON Photocells active only in closing OFF Photocells always active DIP 5 ON blinker pre flashing OFF blinker normal flashing ON STEP BY STEP Single pulse contact K BUTT Pedestrian button PED BUTT Radio Receiver command OFF AUTOMATIC Single pulse contact K BU Pedestrian button PED BUTT DIP 6 4 ST TE ABR of TN lt CE S MOTOR V U V 0000 OK CRX K3 KI T 1 ca SL ID E CHIC CH CH Buzzer a E O co
57. RA AUTOMATICA CON APERTURA PEDONALE empi di pausa prima di avere la chiusura automatica pedonale del cancello vengono egistrati durante la programmazione pedonale empo di pausa massimo di 5 minuti empo di pausa attivabile o disattivabile tramite DIP3 ON attivo FUNZIONAMENTO ACCESSORI DI SICUREZZA FOTOCELLULA COM PHOT DIP 4 0FF gt A cancello chiuso se un ostacolo davanti al raggio delle fotocellule il cancello non apre Durante il funzionamento le fotocellule intervengono sia in apertura con ripristino del moto in apertura solo dopo la liberazione del raggio delle fotocellule che in chiusura con ripristino del moto inverso solo dopo la liberazione del raggio delle fotocellule DIP 4 ON gt A cancello chiuso se un ostacolo davanti al raggio delle fotocellule e viene comandata l apertura il cancello apre durante l apertura le fotocellule non interverranno Le fotocellule interverranno solo in fase di chiusura con ripristino del moto inverso dopo un secondo anche se le stesse restano impegnate NOTA se questo ingresso non viene utilizzato eseguire un ponticello tra i morsetti COM PHOT COSTE PNEUMATICHE MECCANICHE O FOTOCOSTA COM EDGE Se interviene in apertura inverte il movimento in chiusura per 2 secondi e poi si ferma Se interviene in chisura inverte il movimento in apertura per 2 secondi e poi si ferma Se la costa rimane impegnata contatto NO nessuna movimentazione
58. afety devices photocells and safety strip are not active 4 In Point D and Point E procedures all the safety devices photocells and safety strip will be active so they must be properly installed and connected to the control board Any changing of the safety devices input state will stop the Point D and Point E procedure that must be repeated from the beginning POINT D PROGRAMMING 1 The gate must be fully closed 2 Turn DIP2 to ON position LED DL1 starts blinking 3 Press PROG Button motor opens 4 Once reached the open position the open limit switch will cut out motor and the gate travelling will be stored The gap of time between now stop of motor and the next pressing of the PROG button see step 5 below will be then stored as waiting time for Automatic Closing feature 5 Press PROG button gate closes and the Automatic Closing time is stored see DIP3 function to enable or disable the Automatic Closing feature 6 The LED DL1 will turn OFF signalling exit from the Point D procedure Closing of the gate will be carried out at normal speed and only on approaching total closing at low speed depending on the adjustment of LOW SPEED trimmer 7 When the gate leaf reaches the close limit switch plate the motor stops 8 Turn DIP2 to OFF position During Point D procedure safety devices photocells and safety strip are active POINT E PROGRAMMING OF PEDESTRIAN OPENING 1 The gate m
59. an programme the next remote control 5 To finish programming let 10 seconds pass and then press the PROG button briefly The red DL1 LED will stop flashing 6 Reposition DIP 1 to OFF and DIP 2 to OFF 7 You have completed the procedure PROCEDURE FOR DELETING ALL RADIO CODES USED ONLY FOR COMPLETE OPENING You can only delete the codes if the gate is closed 1 Position DIP 1 to ON and then DIP 2 to ON 2 The red programming DL1 LED will flash ON and OFF one second on each for 10 Seconds 3 Press and hold the PROG button for 5 seconds The green DL2 LED will flash twice to confirm that the stored codes have been deleted 4 The red programming DL1 LED remains active and you can programme new codes as shown above if required 5 Reposition DIP 1 to OFF and DIP 2 to OFF 6 You have completed the procedure HOW TO CHECK IF THE MEMORY IS FULL FOR RADIO CODES USED ONLY FOR COMPLETE OPENING You can only check the memory if the gate is closed 1 Position DIP 1 to ON and then DIP 2 to ON 2 The green DL2 LED will flash 6 times if the memory is full 30 codes have been stored 3 After this the DL1 programming LED will remain active for 10 seconds so that you can delete all codes if required 4 Reposition DIP 1 to OFF and DIP 2 to OFF 5 You have completed the procedure POINT G PROGRAMMING RADIO CODES FOR PEDESTRIAN OPENING UP TO 30 CODES ONLY FOR CRX MODELS You can only programme the co
60. an to pass as described into the Point E procedure From the Pedestrian opening position the Automatic Closing can be enabled or disabled with DIP3 From the Pedestrian opening position the gate can be completely opened by the OPEN or by the K BUTT button or by the RADIO button AUTOMATIC CLOSING from the COMPLETE open position The Automatic Closing from the complete open position can be enabled turning ON the DIP3 The maximum gap of time that can be programmed is 5 minutes see Point D AUTOMATIC CLOSING from the PEDESTRIAN open position The Automatic Closing from the pedestrian open position can be enabled turning ON the DIP3 The maximum gap of time that can be programmed is 5 minutes see Point E FUNCTIONING OF SAFETY ACCESSORIES PHOTOCELL PHOT COM In case the switch DIPA is in the OFF position the photocells are active both in gate opening and in gate closing In this configuration if an obstacle cuts the photocell beam while the gate is closing the gate will open while the gate is opening the gate will stop and will restart opening when the obstacle is removed while the gate is still it will not move neither in opening nor in closing In case of the switch DIP4 is in the ON position the photocells are active only in gate closing In this configuration if an obstacle cuts the photocell beam while the gate is closing the gate will open while the gate is opening the gate will continue open
61. anual para mover la puerta no debe superar los 225N para las cancelas colocadas en lugares privados y los 390N para las cancelas colocadas en sitios comerciales e industriales valores indiacados en el punto 5 3 5 de la norma EN 12453 46 50 min K500 s WW M y w Lis AWA L a 97 7 44 El ANCLAJE MOTOR Y CREMALLERA El K500 es suministrado completo con una placa de basis que permite la regulaci n en alto Esta regulaci n en alto es til para mantener una abundancia de 1mm entre el engranaje de arrastre y la cremallera La placa de base es dotada de tres zanjas que pueden ser utilizadas par a la cimentaci n en tierra En alternativa se puede requerir la ap sita placa para cimentaci n para 500 cod ACG8108 Es adem s posible posicionar el K500 con la relativa placa de base dir ctamente sobre la placa de cimentar dedicada al operador K5 c d ACG8101 La placa de base del K500 es adem s dotada de 4 hoyos de fijado a tierra con 4 tornillos a espansi n La cremallera tiene que ser fijada a un determinado alto con respecto al apoyo del motor Dicha altura se puede variar gracias a unos ojales presentes en la cremallera El ajuste de la altura se efect a para que la verja durante el movimiento no se apoye sobre el engranaje de tracci n del K Fig 5 6 Para fijar la cremallera a la verja se practican unos agujeros de 0 5mm y se roscan usando una roscadora del ti
62. arnizione K ACG1071 Chiave di sblocco CME1131 Albero di traino DAC29x95 Vite aut TC CR 2 9x9 5 ZINCAT ACG8672 Serratura esagonale K K500 CME1132 Perno sblocco DAC39x95 Vite aut TC CR 3 9x9 5 DIN798 BA01045 Serie access cilind K500 CMO1318 Rotore con albero K500 DAC35x95 Vite aut TC CR 3 5x9 5 BA10086 Carter K500 completo CMO1345 Statore K500 230 50 60 1P DAC4X10 Vite Autom TC CR 4x10 TRIL UNI BA10087 Ingranaggio traino K500 CM01346 Statore K500 120 60 1P DAC42x16 Vite auto TC CR 4 2x16 CAL1155 Corona elicoidale Sfera molla DAC5x10 Vite Autom TC CR 5x10 TRIL UNI8112 CAL1166 Carcassina campana motore K500 Flangia finecorsa DAE55x16 Vite aut TE 5 5x16 P Tronca Z CCA1178 Gruppo piastra base Boccola DDD6MA Dado autob 6MA ALTO CCA1179 Perno cerniera scatola QE Scatola QE DDMM8 Dado 8MA medio UNI5588 1324 Camme finecorsa DX L Coperchio scatola QE DDMM3Z Dado 3MA medio UNI5588 1325 Camme finecorsa SX Paraolio 20x30x5 DRD4 Rond dent D 4 piano DIN6798 CCM6005ZZ Cuscinetto motore 600577 Molla finecorsa Inox DRL8x26 Rond piana 8 5x26x2 5 CCM620277 Cuscinetto motore 6202 ZZ CTC1205 Molla per sblocco DSB6x25 Vite TSPEI 6x25 UNI5933 CEL1071 Passacavo PG9 CTC1214 Spina CIL 8x32 non temprata DSC3x20Z Vite TSP CR 3x20 CEL1074 Passacavo PG16 CTC1293 Spina CIL 10x55 DST8x45 Grano M8x45 UNI5927 CEL1350 Microswitch a rotella CTC1303 Anello di tenuta OR 158 DTB63x25 Vite 6 3x25 AUTOF ZINC CEL1425 Condensatore 10UF
63. automatica consentita Se non usata ponticellare i morsetti COM EDGE N B Si raccomanda di verificare la funzionalit delle coste almeno ogni 6 mesi ALLARME DA COSTE Dopo un inversione data dall intervento della costa il cancello si ferma nella condizione di allarme segnalata dal lampeggiatore attivo per 1 minuto e dal buzzer attivo per 5 minuti Durante o dopo il minuto di allarme possibile ristabilire il funzionamento del cancello premendo un qualsiasi pulsante di comando MONITORAGGIO COSTE DI SICUREZZA A TEST A Tramite l ingresso A TEST ed il DIP 10 ON possibile monitorare la le costa e monitoraggio consiste in un Test Funzionale della costa eseguito al termine di ogni completa apertura del cancello Dopo ogni apertura la chiusura del cancello viene pertanto consentita solo se la le costa e hanno superato il Test Funzionale ATTENZIONE IL MONITORAGGIO DELL INGRESSO COSTA PU ESSERE ABILITATO CON IL DIP 10 IN ON OPPURE DISABILITATO CON IL DIP 10 IN OFF INFATTI IL TEST FUNZIONALE DELLE COSTE E POSSIBILE SOLO NEL CASO SI TRATTI DI DISPOSITIVI DOTATI DI UN PROPRIO ALIMENTATORE DI CONTROLLO UNA COSTA MECCANICA NON PUO ESSERE MONITORATA PERTANTO IL DIP 10 DEVE ESSERE POSIZIONATO IN OFF ALLARME DA AUTOTEST COSTA DIP 10 ON A fine apertura se il monitoraggio della costa ha esito negativo subentra un allarme visualizzato dal lampeggiatore che rimane acceso e dal buzzer se collegato atti
64. c digos presentes 3 Sucesivamente el led DL1 de programaci n permanece activo por 10 segundos consintiendo la eventual cancelaci n total de los c digos 4 Volver a colocar el DIP 1 en posici n OFF y DIP 3 en OFF 90 5 Final del procedimiento FUNCIONAMIENTO DE LOS ACCESORIOS DE MANDO ADVERTENCIA CONECTE ACCESORIOS DE COMANDO SOLO SI IMPULSIVO Aseg rese de que cualquier otro accesorios de comando que se instalan por ejemplo sensores magn ticos est n programados en el modo de IMPULSO de lo contrario pueden activar el movimiento de la puerta sin tener activos los elementos de seguridad PULSADORE DE MANDO COM K BUTTON Si DIP6 est en ON gt Ejecuta un control c clico de los mandos abrir stop cerrar stop abrir etc Se DIP6 est en OFF gt Efect a la abertura con la verja cerrada Si se acciona durante el movimiento de abertura no tiene ning n efecto Si se acciona con la verja abierta la cierra y durante el movimiento de cierre si se acciona la vuelve a abrir FUNCI N RELOJ Para utilizar la funci n de reloje solicitar K2007 con firmware 12 NOUP ATENCI N UN RELOJ CONECTADO A K2007 con fw 05 o m s IMPLICA EL MOVIMIENTO AUTOM TICO DE LA PUERTA SIN DISPOSITIVOS DE SEGURIDAD ACTIVOS La Funci n Reloj es til en las horas de punta cuando el tr fico de los veh culos est enlentizado Ej Salida entrada de obreros emergencias en reas residenciales o aparcam
65. ca del motore pi l energia cinetica del cancello 12 Fig 2 Le colonne del cancello devono avere superiormente delle guide antideragliamento Fig 3 per evitare involontari sganciamenti N B Eliminare fermi meccanici del tipo descritto in figura 3 Non devono essere presenti fermi meccanici al di sopra del cancello perch non sono sufficientemente sicuri Componenti da installare secondo la norma EN12453 USO DELLA CHIUSURA TIPO DI COMANDO Persone esperte Persone esperte fuori da area Uso illimitato pubblica area pubblica a uomo presente A B non possibile a impulsi in vista CoE CoE CeD oE es sensore a impulsi non in vista CoE CeD oE CeD oE es telecomando automatico CeD oE CeD oE CeD oE esempio tipico sono le chiusure che non accedono a pubblica via A Pulsante di comando a uomo presente cio ad azione mantenuta come cod ACG2013 B Selettore a chiave a uomo presente come cod ACG1010 C Regolazione della forza del motore D Coste e o altri dispositivi di limitazione delle forze entro i limiti della norma EN12453 Appendice A E Fotocellule es cod ACG8026 da applicare ogni 60 70 cm per tutta l altezza della colonna del cancello fino ad un massimo di 2 5 m EN 12445 punto 7 3 2 1 SBLOCCO Da effettuare dopo aver tolto l alimentazione elettrica al motore Per poter agire manualmente sul cancello sufficiente inserire l apposita chiave e ruotarla 3 volte in senso antiorario Fig
66. cada vez que se comanda la cancela se ejecuta por default un arranque gradual de 1 segundo SENALES DEL PILOTO DL1 Rojo Programaci n activada 49 L2 Verde Programaci n radio activada solo en los modelos CRX D DL3 Rojo contacto tope de recorrido de abertura NC DL4 Rojo contacto tope de recorrido de cierre NC DL5 Rojo verja en cierre DL6 Verde verja en abertura DL7 Rojo contacto fotoc lulas NC DL8 Rojo Contacto costas DL9 Rojo Contacto mando peatonal NO C REVISION SENTIDO DEL MOTOR Este control tiene la funci n de facilitar la instalaci n y o para eventuales controles sucesivos 1 Desbloquear el operador a trav s del desbloqueo manual y posicionar las exc ntricas de final de carrera Llevar la cancela hasta la mitad de carrera y bloquear el operador 2 Poner el DIP1 en posici n ON gt el led DL1 inicia a parpadear 3 Presionar y tener presionado el pulsador PROG el movimiento se efect a con alguien presente abre stop cierra stop abre etc gt el LED VERDE DL6 OPEN se enciende y la cancela debe abrir en caso contrario soltar el pulsador PROG e invertir los hilos del motor V y W y detenerse al contacto con el final de carrera el ctrico si esto no sucede soltar el pulsador PROG e invertir los dos hilos del final de carrera LSO y LSC 4 Presionar el pulsador PROG y tenerlo presionado gt el LED ROJO DL5 CLOSE se enc
67. cepci n 433 92MHz Resistencia 520 Sensibilidad gt 2 24uV DEFECTO 300ms 300ms N 60 30 para apertura total y 30 para apertura peatonal Corriente disponible sobre el connector radio 200mA 24Vdc Todos los ingresos se tienen que usar como contactos limpios porque la alimentaci n se produce dentro de la tarjeta y est predispuesta de manera que se garantize el respeto de aislamiento doble o reforzado respecto a las partes en tensi n Todos los ingresos son controlados por un circuito integrado programado que efect a un autocontrol en cada puesta en marcha Tiempo de excitaci n Tiempo de desexcitaci n Codici memorizzabili RESOLUCI N DE PROBLEMAS Despu s de haber efectuado todas las conexiones siguiendo atentamente el esquema y haber posicionado el port n en posici n intermedia verifique el correcto encendido de los led DLA DL7 DL8 En caso de falta de encendido de los led siempre con el port n en posici n intermedia verifique lo que sigue y sustituya eventuales componentes averiados apagado Fin de carrera detenido abertura averiada 014 apagado Fin de carrera detenido cierre averiado DL7 apagado Fotoc lulas averiadas DL8 apagado Borde de seguridad averiado En caso que el borde no este conectado realice el puente entre COM y EDGE Durante el funcionamiento con hombre presente con DIP N 1 en ON verifique que durante la apertura se encienda el led verde DL6 y que durante el cierre se enci
68. cht der Ger te 0 55 kg Raumbedarf 130 x 50 x 115 mm TECHNISCHE DATEN DES RADIOGER TS nur Modelle CRX Empfangsfrequenz 433 92MHz Impedenz 520 Empfindlichkeit gt 2 24uV Erregungszeit 300ms Aberregungszeit 300ms N 60 30 f r Gesamt ffnung und 30 f r Fussg nger ffnung Strom verf gbar auf dem Funkenverbinder 200mA 24VGS Alle Eing nge m ssen als Kontakte ohne Erdung angewandt werden da die Stromversorgung intern von der Karte erzeugt wird und ist so angeordnet dass die doppelte und verst rkte Isolierung der unter Spannung stehenden Teile gesichert wird Alle Eing nge werden durch einen programmierten integrierten Schaltkreis kontrolliert der eine Selbstkontrolle bei jeder Inbetriebnahme durchf hrt L SUNG VON PROBLEMEN Nachdem alle Verbindungen sorgf ltig dem Schema folgend ausgef hrt wurden und das Tor auf die mittlere Position gestellt wurde das korrekte Einschalten der LEDs DL3 DL4 DL5 und DL8 kontrollieren Im Fall dass sich ein LED mit dem Tor immer noch in mittlerer Position nicht einschaltet wie folgt berpr fen und eventuelle besch digte Komponenten ersetzen DL3 ausgeschaltet Endschalter stillstehend ffnung Schaden DL4 ausgeschaltet Endschalter stillstehend Schlie ung Schaden DL7 ausgeschaltet Fotozellen besch digt DL8 ausgeschaltet Sicherheitsrippe Schaden Falls die Rippe nicht angeschlossen ist einen berbr ckungsdraht zwischen COM und EDGE legen W hrend der Totmannfunktion mit DI
69. closes but it has no strength and moves slowly The gate opens but does not close after the time set The gate does not open or close by activating the various K and RADIO buttons By activating the K button the gate does not move The slowing phase is not performed F2 5A Fi 100mA Check trimmers TORQUE and LOW SPEED adjustment Ensure to have set DIP 3 at ON Button K BUTTON always inserted in automatic functioning mode DIP 6 OFF Replace button or switch of the selector switch Failed edge self test gt check the connections between electronic board and edge feeder Attention if not using a feeder for edges DIP 10 must be at OFF position Faulty safety edge contact Faulty photocells contact with DIP 4 OFF Fix or replace the relative contact Impulse K always inserted Check and replace any buttons or micro switches of the selector switch Ensure that DIP 8 is at position OFF slowing enabled Learn the times through procedure from DIP 2 Check trimmer LOW SPEED adjustment 95 ACCESSORIES For the connections and the technical data of the optional equipments follow the relevant handbooks PLATE TO BE CEMENTED code ACG8108 FIT SLIM PHOTOCELLS for the wall installation code ACG8032 PAIR OF COLUMNS FOR FIT SLIM code ACG8065 SLIM photocells have synchronism function in AC current and ranges of 20 m You can fit many couples close together thanks to the synchronising circuit Add the SYN
70. coppie rawicinate tra loro grazie al circuito sincronizzatore Aggiungere il TRASMETTITORE SYNCRO cod ACG8028 per pi di 2 coppie di fotocellule fino a 4 COPPIA DI CESTELLI DA INCASSO PER FIT SYNCRO cod ACG8051 TELECOMANDO SUN SUN 2CH cod ACG6052 SUN 4CH cod ACG6054 SUN CLONE 2CH cod ACG6056 SUN CLONE 4CH cod ACG6058 DISPOSITIVI Wi Fi MASTER Wi Fi SCHEDA DI GESTIONE SISTEMA SENZA FILI con innesto 12 30V ac dc con morsettiera 12 30V ac dc cod ACG6094 cod ACG6099 NOVA Wi Fi FOTOCELLULE SENZA FILI cod ACG8037 COPPIA COLONNINE NOVA cod ACG8039 TASTIERA DIGITALE VIA RADIO da incasso cod ACG9434 da parete cod ACG9436 BLOCK Wi Fi SELETTORE A CHIAVE SENZA FILI cod ACG6098 VERTIGO Wi Fi TOUCH Wi Fi FOTOCELLULE SENZA FILI SOSTITUTIVE DELLA COSTA COSTA SENZA FILI cod ACG3016 VERTIGO Wi Fi 8 VERTIGO Wi Fi 10 cod ACG8042 cod ACG8043 TRASMETTITORE RADIO RED per costa meccanica o elettrica da alimentare con 3 batterie stilo tipo AA da 1 5V non incluse RED permette la realizzazione di un impianto con coste fissate anche sull anta in movimento senza l adozione di sistemi raccogli cavo E conforme alla norma EN13849 1 2007 e congiuntamente ad un quadro elettronico RIB un dispositivo di protezione di Classe 2 cod ACG6202 SPARK Wi Fi a cod ACG7064 cod ACG7042 LAMPEGGIATORE SENZA FILI SUPPORTO LATERALE SCH MA D TAILL DE L INSTALLATION
71. da y se acciona el mando de abertura la verja se abre durante la abertura las fotoc lulas no intervienen Las fotoc lulas intervienen solamente en la fase de cierre restableciendo el movimiento contrario despu s de un segundo a pesar de seguir ocupadas NOTAR Si esta entrada no se utiliza crear un puente entre las grapas COMPHOT COSTAS PNEUM TICAS MEC NICAS O FOTOCOSTA COM EDGE Si interviene en apertura invierte el movimiento y cierra para 2 segundos y luego se detiene Si interviene en cierre invierte el movimiento y abre para 2 segundos y luego se detiene Si la costa permanece comprometida contacto NO no puede realizarse ning n movimiento autom tico Si no est siendo utilizada puentear los bornes COM EDGE Nota Se recuerda verificar el funcionamiento de las costas por lo menos cada 6 meses ALARMAS DE LAS COSTAS Despu s de una inversi n determinada por la intervenci n de la banda de seguridad la puerta se detiene en la condici n de alarma se alada tambi n por la luz intermitente durante 1 minuto y por el buzzer activo para 5 minutos Durante o despu s del minuto de alarma es posible restablecer el funcionamiento de la cancela presionando cualquier pulsador de mando MONITORIZACI N DE COSTAS DE SEGURIDAD A TEST A Por medio del ingreso A TEST y el DIP 10 ON es posible monitorizar la s costa s La monitorizaci n consiste en un Test Funcional de la costa ejecutado al final de cada abert
72. des codes 4 Replacer DIP 1 sur OFF et DIP 2 sur OFF 5 Fin de proc dure F PROGRAMMATION CODES RADIO OUVERTURE PIETONNIERE 30 CODES MAX UNIQUEMENT MODELES CRX La programmation peut tre effectu e uniquement avec le portail ferm 1 Positionner DIP 1 sur ON et ensuite le DIP 3 sur ON 2 La led rouge 011 de programmation clignote avec une fr quence de 1 sec ON et 1 sec OFF pendant 10 secondes 3 Appuyer sur la touche de la t l commande normalement le canal B dans les 10 secondes r gl es Si la t l commande est correctement m moris e la led DL2 verte met un clignotement Le temps de programmation des codes se renouvelle automatiquement pour pouvoir m moriser la t l commande suivante 5 Pour terminer la programmation laisser s couler 10 sec ou bien appuyer pendant un instant sur le bouton PROG La led rouge DL1 de programmation arr te de clignoter 6 Replacer DIP 1 sur OFF et DIP 3 sur OFF REMARQUE SI LA LED DL1 CONTINUE A CLIGNOTER RAPIDEMENT CELA SIGNIFIE QUE LE DIP 1 EST ENCORE POSITIONNE SUR ON ET QUE N IMPORTE QUELLE MANOEUVRE EST REFUSEE 7 Fin de proc dure PROCEDURE ANNULATION DE TOUS LES CODES RADIO PREVUS POUR L OUVERTURE PIETONNIERE L annulation peut tre effectu e uniquement avec le portail ferm 1 Positionner DIP 1 sur ON et ensuite le DIP 3 sur ON 2 La led rouge de programmation clignote avec une fr quence de 1 sec ON et 1 sec OF
73. des if the gate is closed 1 Position DIP 1 to ON and then DIP 3 to ON 2 The red programming DL1 LED will flash ON and OFF one second on each for 10 seconds 3 Press the remote control button normally channel B within the 10 seconds proscribed If the remote control has been correctly programmed the DL2 LED green will flash once 4 The code programming time resets automatically so that you can programme the next remote control 5 To finish programming let 10 seconds pass and then press the PROG button briefly The red DL1 LED will stop flashing 6 Reposition DIP 1 to OFF and DIP 3 to OFF N B IF THE DL1 LED CONTINUES TO FLASH RAPIDLY THIS MEANS THAT DIP 1 IS STILL POSITIONED TO ON AND ANY MANOEUVRE HAS BEEN DELETED 7 You have completed the procedure PROCEDURE FOR DELETING ALL RADIO CODES USED ONLY FOR COMPLETE OPENING You can only delete the codes if the gate is closed 30 1 Position DIP 1 to ON and then DIP 3 to ON 2 The red programming DL1 LED will flash ON and OFF one second on each for 10 seconds 3 Press and hold the PROG button for 5 seconds The green DL2 LED will flash twice to confirm that the stored codes have been deleted 4 The red programming DL1 LED remains active and you can programme new codes as shown above if required 5 Reposition DIP 1 to OFF and DIP 3 to OFF 6 You have completed the procedure HOW TO CHECK IF THE MEMORY IS FULL FOR RADIO CODES USED ONLY FOR CO
74. digkeit am Ende einer jeden Bewegung nach der Stellung des Kraftreglers Bei minimal Stellung des Kraftregler erreicht man den groessten sichtbare Langsambewegung des Antriebes Diese Langsambewegung ist nur auf den letzten 50 60 cm zu sehen ELEKTRONISCHE BREMSE Wenn die Option Geschwindigkeitsabnahme DIP 8 ON nicht in Anspruch genommen wird empfehlen wir den DIP 7 auf ON zu bef higen und eine elektronische Bremse zu benutzen die die Torschwingung verringert wenn dieses den elektrischen Endlauf erreicht GRADUELLER START MIT DIP 9 ON jedes Mal wenn ein Torbefehl gegeben wird erfolgt als Default ein gradueller Start gleich 1 Sekunde 39 LED ANZEIGEN L1 Rot Programmierung aktiviert L2 Gr n Programmierung Radio aktiviert nur bei Modellen CRX D D DL3 Rot Kontakt Offnungsendschalter NC DL4 Rot Kontakt SchlieBendschalte NC DL5 Rot Tor im SchlieBzustand DL6 Gr n Tor im ffnungszustand DL7 Fotozellen Kontakt NC DL8 Rot Rippen Kontakt NC DL9 Rot Kontaktbefehl f r FuBg nger NO C KONTROLLE MOTOR DREHRICHTUNG Diese Kontrolle dient der Erleichterung der Installation w hrend der Inbetriebnahme der Anlage oder der Ausf hrung von m glichen sp teren Kontrollen 1 Den Operator manuell entblocken die Nocken des Endlaufes positionieren dann das Tor auf die Torlaufh lfte bringen und den Operator blockieren 2 DIP1 auf ON
75. e 60 70 cm f r die ganze H he der Spalte des Gatters bis zu einem Maximum von 2 5 m anwenden EN 12445 Punkt 7 3 2 1 ENTRIEGELUNG Die Entriegelung darf erst nach dem Abschalten der elektrischen Das Tor muss einen geeigneten Griff haben Dieser Griff muss so angebracht sein das er kein Risiko ist beim Test Da die physische notwendige Kraft um das Tor Blatt zu bewegen nicht h her als 225N ist f r Tore bei privaten Wohnungen und 390N f r Tore f r kommerzielle und industrielle Situationen Werte nach 5 3 5 vom EN 12453 Norm Um das Tor manuell zu bedienen ist es ausreichend den passenden Schl ssel einzuf hren und 3 Mal entgegen dem Uhrzeigersinn zu drehen Abb 4 Motorstromversorgung erfolgen Um das Tor manuell richtig zu pruefen muessen folgende Punkte beachtet werden z 36 MOTORBEFESTIGUNG UND ZAHNSTANGE Der K500 wird komplett mit einer Untersatzplatte f r die H henregulierung geliefert Diese H henregulierung ist n tzlich um einen Spielraum von 1mm zwischen dem Getriebe und der Zahnstange einzur umen Die Untersetzplatte ist mit drei Expansionsverankerungsbeinen ausgestatte die f r die Boden Einzementierung verwendet werden k nnen Als Alternative kann auch die Zementier Basisplatte die f r den K500 Code ACG8108 geschaffen wurde angefordert werden Ebenso kann der K500 mit seiner Basisplatte direkt auf die Zementierplatte positioniert werden die f r den Operator K5 Code ACG810
76. e f r FuBg nger dr cken COM PED BUTT gt das Tor ffnet sich 3 Die Schalttaste FuBg nger f r den Laufarrest dr cken dabei wird die ffnung des Tores bestimmt 4 Solange warten bis die die gew nschte ffnungszeit erreicht ist ausschlieBbar mit DIP3 auf OFF dann die Schalttaste FuBg nger f r den SchlieBvorgang dr cken 5 BEI ERFOLGTER PROGRAMMIERUNG F R FUSSG NGER DIP1 UND 2 WIEDER AUF OFF STELLEN 4 W HREND DER PROGRAMMIERUNG BLEIBEN DIE SICHERHEITEN AKTIV UND IHR EINGRIFF STOPPT DIE PROGRAMMIERUNG LED DL1 WECHSELT VON BLINKLICHT AUF FIXES LICHT F R DIE WIEDERHOLUNG DER PROGRAMMIERUNG DIP2 AUF OFF STELLEN MIT DER PROZEDUR KONTROLLE ROTATIONSSINN DES MOTORS DAS TOR SCHLIESSEN UND DIE PROGRAMMIERUNG WIE OBEN BESCHRIEBEN WIEDERHOLEN E PROGRAMMIERUNG DER FUNKCODES FUR GESAMTOFFNUNG 30 MAX CODES NUR MODELLE CRX Die Programmierung kann nur bei stillstehendem Tor vorgenommen werden 1 Zuerst DIP 1 auf ON und danach DIP 2 auf ON stellen 2 LED DL1 rot f r die Programmierung blinkt im Abstand von 1 Sekunde bei ON und 10 ekunden bei OFF ie Taste der Fernsteuerung gew hnlich Kanal A innerhalb der eingestellten Zeit von 0 Sekunden dr cken Bei korrekter Speicherung der Fernsteuerung leuchtet das LED L2 gr n auf e Zeit f r die Programmierung der Codes wird automatisch erneuert damit die n chste Fernsteuerung gespeichert werden kann 5 F r die Beendigung der Programmierung 1
77. e manual control of the movement must be done by positioning the keyboard so that the person operating it does not find himself in a dangerous position moreover the risk of accidental activation of the buttons must be reduced Keep the automatism controls push button panel remote control etc out of the children way The controls must be placed at a minimum height of 1 5mt from the D WICHTIGE SICHERHEITS ANLEITUNGEN F R DIE INSTALLATIONEN ACHTUNG F R DIE SICHERHEIT DER PERSONEN IST ES WICHTIG DASS ALLE ANWEISUNGEN GENAU AUSGEF HRT WERDEN ALLE INSTALLATIONSANLEITUNGEN BEFOLGEN 1 Diese Betriebsanleitung dient ausschlieBlich dem Fachpersonal welche die Konstruktionskriterien und die Sicherheits Vorschriften gegen Unf lle f r Tore T ren und automatische Tore kennt geltende Norm befolgen en und Gesetze beachten und 2 Der Monteur muss dem Endkunde eine Betriebsanleitung in bereinkunft der EN12635 berreichen 3 Vor der Installierung muss Sicherheitsgew hrung der identifizierten kritischen 4 Die Verkabelung der verschiedenen externen ele nderungen davon nach Punkt 5 2 2 der EN 12453 5 Die eventuelle Montage einer Schalttafel f r den muss so angebracht werden dass der Benutzer sic Schaltern gering ist f r die automatische SchlieBung und zur Punkte eine Risiko Analyse vorgenommen werden mit der entsprechenden Behebung der identifizierten gef hrlich
78. ed out using the LOW SPEED Trimmer which varies the output voltage to the head s of the motor s turn clockwise to increase speed Adjustment is carried out to establish the correct speed at the completion of opening and closing depending on the structure of the gate or if there is any light friction that could compromise the correct working of the system The low speed is activated DIP8 OFF when the gate leaf is 0 50 0 60 meters away from the complete close or open position 29 ELECTORNIC BRAKE If the low speed in approaching is disabled DIP8 ON is preferable turn the DIP7 ON to enable at least the electronic brake that permits to win the gate leaf inertia when the gate reaches the close or open limit switches GRADUAL START With DIP 9 in the ON mode the gate starts to move gradually for 1 second only LED WARNING L1 programming activated red L2 radio code programming green CRX version only L3 open limit switch contact NC red L4 close limit switch contact NC red L5 gate closing M1 red L6 gate opening green L7 photocell contact NC red L8 safety strip contact NC red L9 Pedestrian opening button red POINT C MOTOR ROTATION DIRECTION CHECK This operation is meant to help the installer during the installation commissioning and for further future controls 1 Unlock the operator with the Manual Release install the limit switch plates
79. emps de programmation des codes se renouvelle automatiquement pour pouvoir m moriser la t l commande suivante 5 Pour terminer la programmation laisser s couler 10 sec ou bien appuyer pendant un instant sur le bouton PROG La led rouge DL1 de programmation arr te de clignoter 6 Replacer DIP 1 sur OFF et DIP 2 sur OFF 7 Fin de proc dure PROCEDURE ANNULATION DE TOUS LES CODES RADIO PREVUS POUR L OUVERTURE TOTALE L annulation peut tre effectu e uniquement avec le portail ferm 1 Positionner DIP 1 sur ON et ensuite le DIP 2 sur ON 2 La led rouge DL1 de programmation clignote avec fr quence de 1 sec ON et 1 sec OFF pendant 10 secondes 3 Appuyer sur le PROG et le maintenir enfonc pendant 5 secondes L annulation de la m moire est signal e par deux clignotements de la led verte DL2 4 Laled rouge DL1 de programmation reste active et il est possible d ins rer de nouveaux codes comme dans la proc dure d crite ci dessus 5 Replacer DIP 1 sur OFF et DIP 2 sur OFF 6 Fin de proc dure SIGNALISATION MEMOIRE SATUREE CODES RADIO PREVUS POUR L OUVERTURE TOTALE La signalisation peut s obtenir uniquement avec le portail ferm 1 Positionner DIP 1 sur ON et ensuite le DIP 2 sur ON 2 La led verte DL2 clignote 6 fois en signalant la m moire satur e 30 codes pr sents 3 Ensuite la led DL1 de programmation reste active pendant 10 secondes en permettant une ventuelle annulation totale
80. en Punkte die Normen EN 12453 EN 12445 befolgend ktrischen Komponenten zum Operator z B Fotozellen Blinker etc muss nach EN 60204 1 ausgef hrt werden manuellen Bewegungsbefehl h nicht in einer Gefahrenzone befindet und dass das Risiko einer zuf lligen nicht gewollten Aktivierung von 6 Alle Steuerungselemente Schalttafel Fernbedienung etc geh ren nicht in ground and outside the range of the mobile 7 Before carrying out any installation regula System take off the voltage by operating o connected upstream it THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible damages caused by the non observance during the installa laws in force at present parts ion or maintenance operation of n the special magnetothermic swi he ch ion of the safety standards and of he Reichweite von Kindern Die Kommandos m ssen min auBerhalb des Aktionsbereiches der mobilen Teile angebracht werden 5 m ab Boden und 7 Vor jeglichem Eingriff sei es Installation Regulation oder Wartung der Anlage muss vorher die Stromzufuhr unterbrochen werden den daf r besti Magnetthermo Schalter dr cken der am Eingang der Anlage installiert ist DIE FIRMA RIB BERNIMMT KEINE VERANTWORTUNG f r eventuelle Sc mmten h den die entstehen k nnen wenn die Installierungsvorschriften die den g ltigen KEEP THESE INSTRUCTIONS WITH CARE de ars 9 4 In
81. enda el led rojo DL5 En caso contrario invierta los bornes V y W en el bornero del motor SOLUCI N Despu s de haber efectuado varias conexiones y haber dado tensi n todos los led est n apagados El motor abre y cierra pero no tiene fuerza y se mueve lentamente El port n ejecuta la apertura pero no cierra despu s del tiempo configurado El port n no abre y no cierra accionando los pulsadores K y RADIO Accionando el pulsador K el port n no ejecuta ning n movimiento La fase de desaceleraci n no se ejecuta Verifique la integridad de los fusibles F1 y F2 En caso de fusible interrumpido use solo de valor adecuado Verifique regulaci n trimmers TORQUE y LOW SPEED Aseg rese de haber configurado el DIP 3 en ON Pulsador K BUTTON siempre habilitado en modalidad de funcionamiento autom tico DIP 6 OFF Sustituya pulsador o switch del selector Fallo Autotest borde gt verifique las conexiones entre el cuadro electr nico y alimentador para bordes Atenci n si no se est utilizando un alimentador para puertas el DIP 10 debe ser en posici n OFF F2 5A F1 100mA Contacto borde de seguridad averiado Contacto fotoc lulas averiado con DIP 4 OFF Arregle o sustituya el correspondiente contacto Impulso K siempre habilitado Controle y sustituya eventuales pulsadores o micro interruptores del selector Aseg rese que el DIP 8 este en posici n OFF desaceleraci n habilitada Realice el aprendiza
82. ermeture en tournant dans le sens des aiguilles d une montre on donne plus de vitesse au moteur Le ralentissement est d termin automatiquement par la centrale en phase de programmation des temps et est active environ 50 60 cm avant l atteinte du fin de course d ouverture ou de fermeture FREIN ELECTRONIQUE Si le rallentissement n est pas utilis dip 8 ON nous conseillons d habiliter le dip 7 ON profitant d un frein lectronique qui limite l inertie du portail quand il atteint un fin de course lectrique na DEPART GRADUEL Avec DIP 9 ON chaque fois que le portail est command un d part graduel d 1 seconde est ex cut par d faut SIGNALISATIONS VOYANTS LUMINEUX L1 Rouge Programmation activ e L2 Ver Programmation radio activ e seulement pour les mod les CRX L3 Rouge Contact fin de course d ouverture NF L4 Rouge Contact fin de course de fermeture NF L5 Rouge Portail en phase de fermeture L6 Vert Portail en phase d ouverture L7 Rouge Contact photocellules NF L8 Rouge Contact cordon NF L9 Rouge Contact commande pi tonne NON C7 C CONTROLE DU SENS DE ROTATION DU MOTEUR Ce contr le a pour but de rendre plus ais e la t che de l installateur lors de la mise en uvre de l installation ou pour tous ventuels contr les successifs 1 D bloquer l op rateur l aide du d blocage manuel et position
83. es r gles A la restauration du contact de s curit l op ration automatique ou pas pas est restaur e apr s une seconde et donc aussi la t l commande et la fermeture automatique sont de travail Note 1 Au cours de cette op ration dans le cas de panne de les barres palpeuses ou cellules photo lectriques les cellules photo lectriques ou barres palpeuses qui ne sont pas en panne fonctionnent encore avec l interruption de l op ration en cours La manoeuvre homme present est exclusivement une manoeuvre d urgence qui doit tre effectu e pour des temps brefs et avec la s curit de la vue quand l op rateur est en mouvement D s possible les protections en panne doivent tre r tablies pour un correct fonctionnement FEU CLIGNOTANT N B Ce coffret lectronique NE PEUT ALIMENTER QUE DES FEUX CLIGNOTANTS AVEC CIRCUIT CLIGNOTANT ACG7059 avec lampe de 40W maximum FONCTION PR CLIGNOTEMENT Avec DIP5 sur OFF gt le moteur le feu clignotant et le buzzer d marrent tous en m me temps Avec DIP5 sur ON gt le feu clignotant et le buzzer d marrent 3 secondes avant le moteur BUZZER Option COM BUZZER Courant fourni pour le fonctionnement du buzzer 200 mA 24Vdc Pendant l ouverture et la fermeture le buzzer mettra un signal sonore intermittent En cas d intervention des dispositifs de s curit alarme cordon ce signal sonore augmente la fr quence de l intermittence VOYANT DE SIGNALISATION PORTAIL
84. eser Anschluss ist empfehlenswert bei der Funktion automatische Anwendung DIP 6 OFF Bei allen Operationen f hrt der Schalter STOP den Tor Arrest aus ARBEIT IM MANNSBEISEIN IM FALL EINES AUSFALLS DER SICHERHEITEN Wenn die Kontaktleiste ist defekt oder diese arbeit l nger als 5 Sekunden oder wenn die Fotozelle defekt ist oder f r mehr als 60 Sekunden arbeit die Befehle K UND FUBGANGERZONE TASTE im Mannsbeisein arbeiten 41 Die Aktivierung dieser Meldefunktion wird durch die Programmier LED blinkt gegeben Dieser Vorgang darf ge ffnet oder geschlossen werden nur durch Halten der Tasten steuern Die Funksteuerung und automatische SchlieBung sind ausgeschlossen weil ihr Betrieb nicht an die Regeln erlaubt Nach der Wiederherstellung der Sicherheit ist nach einer Sekunde automatisch in automatischen Funktion oder Schritt f r Schritt restauriert und damit auch die Fernbedienung und das automatische Schlie en wieder m glich Anmerkung 1 W hrend dieses Vorgangs Fotozellen oder Kontaktleisten die nicht kaputt sind funktionieren noch Unterbrechung des Betriebs im Gange Die Totmannschaltung Bedienung ist n r eine Not Bedienung und die f r kurze Zeit und mit der Visuell Sicherheit der Autmatismum Bewegung gemacht wird sein So bald wie m glich muss der Fehler Schutz f r den ordnungsgem en Betrieb wiederhergestellt werden sein BLINKLICHT ANMERKUNG Diese elektronische Tafel kann NUR BLINKER MIT BLINKSCHALTU
85. espondant 3mm la marque de cet interrupteur devra tre en conformit avec les normes internationales Ce dispositif doit tre prot g contre toute remise en fonction accidentelle ex en l installant dans un coffre fermant cl En ce qui concerne la section et le type des c bles le conseil de RIB est celui d utiliser un c ble de type HOSRN F pr sentant une section minimale de 1 5mm et quoi qu il en soit de se conformer la norme IEC 364 ainsi qu aux normes d installation en vigueur dans le pays de destination Positionnement d un ventuel jeu de photocellules le faisceau des photocellules ne doit pas tre une hauteur sup rieure 70 cm du sol et 20 cm du bord du vantail Leur correct effectivit fonctionnement doit tre v rifi terminant l installation selon le point de la 7 2 1 de la EN 12445 Afin de satisfaire aux limites impos es par la norme EN 12453 si la force d impact d passe la limite de 400N il sera n cessaire de d tecter une pr sence sur la hauteur totale du portail jusqu un maximum de 2 5m Les cellules photo lectriques dans ce cas ci doivent tre s appliquent ext rieurement entre les colums et int rieurement pour toute la course de la pi ce de mobil chaque 60 70 pour toute la taille de la colonne de la porte jusqu un maximum de 2 5 EN 12445 point 7 3 2 1 exemple taille 2 2m de colonne gt 6 copies des cellules photo lectriques 3 internes et 3 externes meilleur si co
86. finch il cancello durante il movimento non si appoggi sull ingranaggio di trazione del K500 Fig 5 e 6 Per fissare la cremagliera sul cancello eseguire dei fori di 0 5 mm e filettarli utilizzando un maschio del tipo M6 L ingranaggio di traino deve avere circa 1 mm di agio rispetto alla cremagliera Misure in mm 5 FISSAGGIO FINECORSA Per determinare la corsa della parte mobile si devono posizionare due camme alle estremit della cremagliera Fig 9 La regolazione della corsa di apertura e chiusura si ottiene spostando le medesime sui denti della cremagliera Per bloccare le camme alla cremagliera avvitare a fondo le viti in dotazione N B Oltre alle di fermo elettrico sopraesposte obbligatoria l installazione di fermi meccanici robusti che non permettono la fuori uscita del cancello dalle guide superiori MANUTENZIONE Da effettuare solamente da parte di personale specializzato dopo aver tolto l alimentazione elettrica al motore Pulire periodicamente a cancello fermo la guida di scorrimento da sassi e altra sporcizia Misure in mm Misure in mm 0 0 5 1 COLLEGAMENTI ELETTRICI VE ANTENNA ALIMENTAZIONE SPARK 230Vac 50 Hz 230Vac 40W PEDONALE BUZZER COMUNE PASSO PASSO COSTA MECCANICA FOTOCELLULE 24Vdc 0 4A 15 24Vdc 0 4A 15 ACCESSORI gt 7 AUTOTEST PER COSTA gt PASSO PASSO PEDONALE
87. h firmware 12 NOUP ATTENTION A CLOCK CONNECTED TO K2007 with fw 05 or more ACTIVATES THE AUTOMATIC MOVEMENT OF THE GATE WITHOUT HAVING THE PROTECTION OF THE SAFETY DEVICES The Clock Function is useful during rush hours when traffic is heavy and the flow is slow e g entrance exit of employees emergencies in residential areas or car parks and temporarily for removal vans and it s necessary to keep the gate opened CLOCK FUNCTION APPLICATION It is necessary to request a K2007 control panel with firmware 12 NOUP Select the automatic functioning DIP 6 OFF It can be done by connecting a switch and or a daily weekly clock either in parallel to the K BUTT button or instead of the K BUTT button When the control board receives this command the gate will open and by keeping this contact closed for all the time of the gate opening the Clock Function is automatically activated In fact once reached the open position the gate will remain opened and all of the control board functions are blocked Only when K BUTT contact is released the control board functions are re activated and the Automatic Closing restarts if enabled doing the countdown to the gate closing PEDESTRIAN command PED BUTT COM This command is useful to open the gate partially just enough for example to permit a pedestrian crossing In fact the Pedestrian command see Point E is carried out only by opening the gate just enough for a pedestri
88. ico se ponen en funci n Con DIP 5 en ON gt el intermitente y el avisador ac stico se ponen en funci n 3 segundos antes del motor BUZZER Opci n COM BUZZER Corriente disponible para el funcionamiento del buzzer 200 mA a 24Vdc Durante la apertura y el cierre el buzzer emitir una se al sonora intermitente En caso de intervenci n de los dispositivos de seguridad alarma costa esta se al sonora aumenta la frecuencia de la intermitencia INDICADOR DE SE ALIZACI N DE CANCELA ABIERTA A negativo LSC Tiene la tarea de indicar los estados de cancela abierta parcialmente abierta o de todas maneras no cerrada totalmente S lo con la cancela completamente cerrada se apaga conectar en serie a indicador una resistencia de 2 2 Si excede con el indicador la l gica de la central resultar comprometida con la posibilidad de bloqueo de las operaciones CARACTER STICAS T CNICAS GENERALES Humedad lt 95 senza condensazione Tensi n de alimentaci n 230V 10 120V 10 bajo requesta Frecuencia 50 60Hz Microinterrupciones de red 20ms Potencia m xima disponible a la salida del motor 1CV Carga m xima a la salida del destellador 40W con carico resistivo Absorci n m xima tarjeta sin accesorios 33mA Corriente disponible para las fotoc lulas 0 4 15 24Vdc Grado de protecci n IP54 Peso del equipo 0 55 kg Medidas 130 x 50 x 115mm CARACTER STICAS T CNICAS DEL RADIORRECEPTOR solo modelos CRX Frecuencia de re
89. iende y la cancela debe cerrrar y luego pararse al contacto con el final de carrera el ctrico 5 Despu s de 2 seg y hasta 10 seg de trabajo consecutivos en apertura o en cierre se acciona autom ticamente la fricci n Efectuar la regulaci n de la electr nica accionando el trimmer TORQUE 6 Despu s de 10 seg de trabajo consecutivos en abertura o en cierre se acciona autom ticamente la deceleraci n si DIP 8 OFF realizar la regulaci n de la velocidad decelerada accionando el trimmer LOW SPEED escogiendo la velocidad deseada 7 Al terminar el control y las regulaciones de los trimmer reponer en posici n OFF El led DL1 se apaga indicando el termine del control N B Durante este control las nervaduras y las fotoc lulas no son activas D PROGRAMACI N DE TIEMPOS DE ABERTURA TOTAL CUIDADO Si las entradas PHOT e EDGE no est n conectadas efectuar una uni n entre COM PHOT y COM EDGE antes de proceder con la programaci n La programaci n se puede efectuar sin tener cuidado a la posici n de la puerta 1 Poner el micro interruptor DIP2 en posici n ON gt El piloto DL1 parpadear 2 Apretar el pulsador PROG gt La verja se cierra Despu s de 2 segundos que se ha cerrado la puerta se abre sola Se parar al final de la abertura Dejar abierto el tiempo deseado excluible con DIP3 OFF 3 Apretar el pulsador PROG para controlar el cierre de la verja se termina tambi n la cuenta del tiemp
90. ientos y tiemporalmente en caso de mudanzas MODALIDAD DE APLICACI N FUNCI N RELOJ Solicitar K2007 con firmware 12 NOUP Seleccione el funcionamiento autom tico DIP 6 OFF Conectando un interruptor y o un reloj de tipo d a semana en lugar o en paralelo con el pulsador de abertura n a COM K BUTTON es posible abrir y mantener abierto el mecanismo hasta que se apriete el pulsador o el reloj quede activado Estando el mecanismo abierto se inhiben todas las funciones de mando Dejando la botonera o al vencer el tiempo insertado se tendr el cierre inmediato del mismo PULSADOR DE ABERTURA PEATONAL COM PED BUTTON Mando dedicado a una abertura parcial y a su cierre Durante la abertura la pausa o el cierre peatonal es posible comandar la abertura desde cualquier mando conectado a la tarjeta Por medio de DIP 6 es posible elegir la modalidad de funcionamiento del pulsador de mando peatonal Si DIP6 est en ON gt Efect a un mando c clico de los comandos abre stop cierra stop etc Si DIP6 est en OFF gt Efect a la abertura con la cancela cerrada Si se acciona durante el movimiento de abertura no tiene efecto Si se acciona con a cancela peatonal abierta la cierra y durante el cierre si es accionado la hace abrir MANDO A DISTANCIA para apertura total y para apertura peatonal DIP6 est en ON gt Ejecuta un control c clico de los mandos abrir stop cerrar stop abrir etc Si DIP6 est en
91. il pulsante PROG e mantenerlo premuto gt il LED ROSSO DL5 CLOSE si accende e il cancello deve chiudere e in seguito fermarsi al contatto con il finecorsa elettrico Dopo 2 sec e fino a 10 sec di lavoro consecutivi in apertura o chiusura si innesca automaticamente la frizione elettronica Eseguite la regolazione della frizione elettronica agendo sul trimmer TORQUE Dopo 10 sec di lavoro consecutivi in apertura o in chiusura si innesca automaticamente il rallentamento se DIP 8 OFF Eseguite la regolazione della velocit rallentata agendo sul trimmer LOW SPEED scegliendo la velocit desiderata Al termine del controllo e delle regolazioni dei trimmer rimettere DIP1 in posizione OFF led DL1 si spegne segnalando l uscita dal controllo N B Durante questo controllo le coste e le fotocellule non sono attive D PROGRAMMAZIONE TEMPI APERTURA TOTALE 8 ATTENZIONE Se gli ingressi PHOT e EDGE non sono collegati eseguire dei ponticelli tra COM PHOT e COM EDGE prima di procedere con la programmazione La programmazione pu essere eseguita con il cancello in qualsiasi posizione 1 2 4 5 NOTA Il Mettete il microinterruttore DIP 2 in posizione ON gt Il led 011 emetter dei lampeggi brevi Premete il pulsante PROG gt il cancello si chiude Dopo 2 secondi che si e chiuso il cancello si apre da solo A fine apertura si ferma Attendete il tempo che desiderate il cancello resti aperto esc
92. is zu einem Maximum 7 3 2 1 Beispiel Spalte H he 2 2m gt 6 Kopien 3 extern besser wenn komplett von der syncronisi mit TX SYNCRO 2445 Norm ihr korrektes Funktionieren muB einmal berpr ft werden r Achse des Tores sitzen das mit dem Punkt 7 2 1 der EN en notwendig eine komplette Sicherheitslieiste zu installieren bei denen mehr als 400N Kraft aufgewand werden muessen um das Tor zum anhalten zu bringen Maximum von 2 5m anwenden Die Fotozellen m ssen in diesem Fall sein beantragen auBen zwischen den colums ede 60 70cm f r die ganze von 2 5m EN 12445 Punkt von Fotozellen 3 intern und m Eigenschaft FIT SYNCRO ANMERKUNG Die Erdung der Anlage ist obligatorisch Die in diesem Handbuch aufgef hrten Daten sind ausschl ieBlich empfohlene Werte RIB beh lt sich das Recht vor das Produkt zu jedem Zeitpun muss in bereinstimmung mit den g ltigen Normen und t zu modifizieren Die Anlage Gesetzen montiert werden IMPORTANTES INSTRUCCIONES DE SEGURIDAD PARA S LA INSTALACI N CUIDADO UNA INCORRECTA INSTALACI N PUEDE CAUSAR GRAVES DA OS SEGUIR TODAS LAS INSTRUCCIONES DE INSTALACI N 1 Este manual de instrucciones est exclusivamente dirigido a personal especializado que conozca los criterios de construcci n y de los dispositivos de protecci n contra accidentes con cancelas puertas y portales motorizados atenerse a las normas y a las leyes vigentes 2 El instalador tendr
93. iven by the blinking of the programming led With the blinking of the programming led the opening and closing operation are allowed only with the command button pressed and held The radio commands and that of automatic closing will be excluded since their use in this mode is not allowed by the norms Once the failing safety device is repaired in automatic after 1 second all standard 31 commands that were selected such as step by step automatic mode radio commands and automatic closing start functioning again Note 1 during this functioning in dead man mode in case of damage to the safety strips or photocells the photocells or safety strips still work by interrupting the operation in progress The dead man operation is only an emergency operation which must be activated for a very short period and with the complete installation at sight so to have a secure and safe control of the system As soon as possible however the failing safety devices must be repaired and activated FLASHING LIGHT Connect the flashing light to J7 flashing light outputs use flashing lights ACG7059 and bulbs of 40W maximum NB This electronic K board can only supply power to FLASHING LIGHTS with inbuilt flashing circuit PRE FLASHING function The DIP 5 in the ON position enables the pre flashing the FLASHING LIGHT and BUZZER starts working 3 seconds before every movement of the gate The DIP 5 in the OFF position disables any pre fla
94. je de los tiempos mediante el proceso con DIP 2 Verifique regulaci n trimmer LOW SPEED 92 OPCIONALES Para las conexiones y datos t cnicos de los accesorios consultar los manuales respectivos PLACA A CEMENTAR c d ACG8108 FIT SLIM FOTOC LULAS PARA PARED c d ACG8032 PAR DE COLUMNAS PARA FIT SLIM c d ACG8065 Las fotoc lulas FIT SLIM tienen una funci n de sincronizaci n en corriente alterna y portada de 20 metros Pueden ser aplicadas m s parejas de fotoc lulas cercanas gracias al circuito de sincronizaci n A adir el TRANSMISOR TX SLIM SYNCRO para sincronizar hasta 4 parejas de fotoc lulas c d ACG8029 TOUCH COSTA MEC NICA L 2 m CERTIFICADA EN 13849 2 2008 CATEGOR A 3 c d ACG3015 PROBE 4 Sonda relevaci n temperatura ambiente motor para calefacci n del mismo en climas particularmente fr os hasta 30 C conector al J8 c d ACG4665 CREMALLERA MOD 4 DE NYLON con angular galvanizado en barras de 1 metro Ideal para verjas hasta 1000 kg 22001bs de peso 1m c d ACS9000 10m 1mx 10 c d ACS9001 FIT SYNCRO FOTOCELULAS FIT SYNCRO DE PARED c d ACG8026 Capacidad de carga ajustable 10 20m Se pueden aplicar varias parejas aproximadas entre si gracias al circuito sincronizador A adir el TRANSMISOR SYNCRO c d ACG8028 para m s de 2 parejas de fotoc lulas hasta 4 PAREJA DE COFRES ENSAMBLABLES PARA SYNCRO c d ACG8051 TELEMANDO SUN a a SU
95. llen Kontakt NC EDGE Rippen Kontakt bei ffnung und Schlie ung ah Verbindung zu Ton Signal 24Vdc max 200 mA NEGATIV J7 2s Blinker max 40W U MOTOR Gemeinsamer anschluss motor V W Verbindung wechselgetriebe und kondensator motor MOTOR J8 PROBE Konnektor f r Sondenanschluss f r Heizer Kode ACG4665 Optional RELAIS UND BEDIENUNG DES MOTORS K1 gt Kommando Blinker K2 gt Kommando Direktion Schlie ung K3 gt Kommando Direktion ffnung 01 gt TRIAC Kommando Motor ffnung Schlie ung B DIE MIKROBEDIENUNGSSCHALTER EINSTELLEN ON MIKROBEDIENUNGSSCHALTER F R PROZEDUREN DIP 1 KONTROLLE MOTOR DREHRICHTUNG ON PUNKT C DIP2 PROGRAMMIERUNG ZEITEN ON PUNKT D DIP 2 1 ZEITENPROGRAMMIERUNG F R DIE FUSSG NGER FFNUNGSZEIT DIP 2 ON GEFOLGT VON DIP 1 ON PUNKT D DIP 1 2 SPEICHERUNG L SCHUNG FUNKCODES F R STEUERUNG GESAMT FFNUNG DIP 1 auf ON gefolgt von DIP 2 auf ON PUNKT E NUR F R DIE MODELLE CRX 1 3 SPEICHERUNG L SCHUNG FUNKCODES STEUERUNG FUSSG NGER FFNUNG DIP 1 auf ON gefolgt von DIP 3 auf ON PUNKT F NUR F R DIE MODELLE CRX MIKROSCHALTER BETRIEB DP3 Wartezeit vor der automatischer SchlieBung ON DIP 4 Fotozellen st ndig bet tigt OFF Fotozellen nur bei der Schlie ung bet tigt ON DIP 5 Vorblinken ON Normales Blinken OFF DIP 6 Befehl Einzelimpuls BUTT und RADIO schrittweise ON automatisch OFF DIP 7 Elektronische Bremse ON aktiviert D
96. long as activated like code ACG2013 B Key selector with manned operation like code ACG1010 C Adjustable power of the motor D Safety strips and or other safety devices to keep thrust force within the limits of EN12453 regulation Appendix A E Photocells like code ACG8026 To apply every 60 70 for all the height of the column of the gate up to a maximum of 2 5m EN 12445 point 7 3 2 1 RELEASE To operated after the power supply to the motor has been interrupted In order to work manually on the gate you just need to insert the fitting key and rotate it 3 times counterclockwise fig 4 In order to carry out the manual operation of the gate leaf the followings must be checked That the gate is endowed with appropriate handles That these appropriate handles are placed so to avoid safety risks for the operator That the physical effort necessary to move the gate leaf should not be higher than 225 N for doors gates for private dwellings and 390N for doors gates for commercial and industrial sites values indicated in 5 3 5 of the EN 12453 norm 26 50 min K500 tH gt DOM MOTOR AND RACK FITTING Operator K500 comes with a base plate for vertical adjustment Such adjustment proves to be useful to set a 1mm clearance between the drive gear and the rack The base plate is provided with three brackets that can be used to fasten the equipment to the floor As an alternative i
97. ludibile con DIP3 OFF Premete il pulsante PROG per comandare la chiusura del cancello il led DL1 smette di ampeggiare nello stesso istante si ferma anche il conteggio del tempo d attesa prima della chiusura automatica max 5 minuti Raggiunto il finecorsa di chiusura il cancello si ferma A FINE PROGRAMMAZIONE RIMETTERE IL DIP 2 SU OFF allentamento viene determinato automaticamente dalla centralina in fase di programmazione tempi e viene attivato a circa 50 60 cm prima del raggiungimento del finecorsa di apertura o chiusura Tale misura pu variare leggermente a secondo della temperatura D PROGRAMMAZIONE TEMPI APERTURA PEDONALE A y 2 3 4 5 cancello chiuso Mettere prima il DIP2 su ON il led DL1 lampeggia velocemente e dopo il DIP1 su ON il led DL1 lampeggia lentamente Premere il pulsante pedonale COM PED BUTT gt il cancello apre Premere il pulsante pedonale per arrestare la corsa definendo cosi l apertura del cancello Attendere il tempo che si vuole rimanga aperto escludibile con il DIP3 su OFF quindi premere il pulsante pedonale per avviare la chiusura A FINE PROGRAMMAZIONE PEDONALE RIMETTERE I DIP 1 E 2 SU OFF DURANTE LA PROGRAMMAZIONE LE SICUREZZE SONO ED IL LORO INTERVENTO FERMA LA PROGRAMMAZIONE IL LED DL1 DA LAMPEGGIANTE RIMANE ACCESO FISSO PER RIPETERE LA PROGRAMMAZIONE POSIZIONARE IL DIP 2 SU OFF CHIUDERE LA PORTA TRAMITE L
98. lusivamente una manovra di emergenza che deve essere effettuata per brevi periodi e con la sicurezza visiva del movimento dell automatismo Appena possibile le protezioni guaste devono essere ripristinate per un corretto funzionamento 11 LAMPEGGIATORE N B Questo quadro elettronico pu alimentare SOLO LAMPEGGIATORI CON CIRCUITO LAMPEGGIANTE ACG7059 con lampade da 40W massimo FUNZIONE PRE LAMPEGGIO Con DIP 5 su OFF gt il motore il lampeggiatore ed il buzzer partono contemporaneamente Con DIP 5 su ON gt il lampeggiatore ed il buzzer partono 3 secondi prima del motore BUZZER Opzionale COM BUZZER Corrente fornita per il funzionamento del buzzer 200 mA a 24Vdc Durante l apertura e la chiusura il buzzer dar un segnale sonoro intermittente Nei casi di intervento delle sicurezze allarme costa questo segnale sonoro aumenta la frequenza dell intermittenza LED SEGNALAZIONE CANCELLO APERTO A negativo LSC Ha il compito di segnalare gli stati di cancello aperto parzialmente aperto o comunque non chiuso totalmente Solo a cancello completamente chiuso si spegne N B collegare in serie al led una resistenza da 2K2 Se si eccede utilizzando pi led la logica della centralina ne risulter compromessa con possibile blocco delle operazioni CARATTERISTICHE TECNICHE Umidit lt 95 senza condensazione Tensione di alimentazione 230V 10 120V 10 a richiesta Frequenza 50 60Hz Microinterruzioni di rete 20
99. m em 1 Ht 10 D T ol all O O PED OJ 8 118 m 7 CH com DI Q O Por ele me m bw 5 CO OJ Lso a EM o E Sols Boo 3 q O Ol al q SV PROG __ J6 JA TEST O TE e Je p N LJ 5 PROBE c s pid SPEED O 0 dl c JPL GND RADIO PN 050106 RI TRIMMER Electronic regulator for low speed on approach LOW SPEED R2 TRIMMER Electronic torque regulator TORQUE Radio Receiver command ON electronic brake ENABLED OFF electronic brake DISABLED ON low speed in approaching DISABLED OFF low speed in approaching ENABLED ON gradual start ENABLED OFF gradual start DISABLED DIP 10 ON safety strip self test ENABLED OFF safety strip self test DISABLED DIP 11 ON DIP 12 OFF S1 gt PROG Programming button DIP 7 DIP 8 DIP 9 TORQUE gt R1 Electronic regulator for motor torque Adjustment of motor torque is carried out using the TORQUE Trimmer which varies the output voltage to the head s of the motor s turn clockwise to increase torque This torque control is activated after 2 seconds form any manoeuvre begging whereas the motor is turned on at full power to guarantee the starting at the manoeuvre begging PAY ATTENTION IF THE TORQUE TRIMMER SETTING IS CHANGED IT IS PREFERABLE TO REPEAT THE TIME PROGRAMMING LOW SPEED gt R1 Electronic regulator for low speed on approach Adjustment of low speed is carri
100. m canique au dessus du portail tant donn que les arr ts m caniques ne sont pas suffisamment s rs Parties installer conform ment la norme EN12453 USAGE DE LA FERMETURE DE COMMANDE Personne expertes personne expertes me au dehors d une zone zone publique Usage illimit publique PU homme presente A B non possible CouE CouE C et D ou E es capteur impulsion hors de vue Cou E C et D ou E C et D ou E es bo tier de commande automatique C et D ou E C et D ou E C et D ou E example typique fermetures qui n ont pas d acc s un chemin public A Touche de commande homme present action maintenue code ACG2013 B S lecteur clef homme mort code ACG1010 C R glage de la puissance du moteur D Barre palpeuse et ou autres dispositifs de limitation des forces dans les limites de la norme EN12453 appendice A E Cellules photo lectriques code ACG8026 Appliquer chaque 60 70 cm pour toute la taille de la colonne de la porte jusqu un maximum de 2 5 m EN 12445 point 7 3 2 1 D BLOCAGE Cette op ration ne devra tre effectu e qu apr s avoir mis le moteur hors tension Afin de pouvoir agir manuellement sur le portail il suffit d introduire la cl destin e cet effet et de la faire tourner 3 fois dans le sens contraire celui des aiguilles d une montre fig 4 Afin de pouvoir manceuvre manuellement le vantail il est important de v rifier que
101. matic entry systems DICHIARAZIONE DI CONFORMIT DECLARATION OF COMPLIANCE D CLARATION DE CONFORMIT BEREINSTIMMNUGSERKL RUNG DECLARACI N DE CONFORMIDAD Dichiariamo sotto la nostra responsabilit che l operatore K500 conforme alle seguenti norme Direttive Declaram EN 3 EN 3 EN 3 EN 3 EN 5 L op rateur K500 se conforme aux normes suivantes We declare under our responsibility that K500 operator is conform to the following standards Wir erklaeren das der K500 den folgenden EN Normen entspricht os bajo nuestra responsabilidad que los operators K500 es conforme a la siguientes normas y disposiciones 01 489 1 2011 EN 55014 2 2009 EN 61000 6 1 2007 01 489 3 2013 EN 60335 1 2014 EN 61000 6 2 2006 00 220 1 2012 EN 60335 2 103 2010 EN 61000 6 3 2013 00 220 3 2010 EN 61000 3 2 2011 EN 61000 6 4 2013 5014 1 2012 EN 61000 3 3 2014 Inoltre permette un installazione a Norme Permit en plus une installation selon les normes suivants You can also install according to the following rules Desweiteren genehmigt es eine Installation der folgenden Normen Adem s permite una instalaci n seg n las Normas EN 12453 2002 EN 12445 2002 EN 13241 1 2011 Come richiesto dalle seguenti Direttive Conform ment aux Directives As is provided by the following Directives Wie es die folgenden Richtlinien verf gen Tal y como requerido por las siguientes Disposiciones 2006 95 CE 2004 108 CE Il presente prodotto non pu funzionare i
102. mplet du dispositif de syncronism FIT SYNCRO avec TX SYNCRO o La mise terre de l installation est obligatoire Les donn es figurant dans le pr sent manuel sont fournies titre purement indicatif RIB se r serve le droit de les modifier tout moment sans aucun pr avis Effectuer l installation en conformit avec les normes et les lois en vigueur G B IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION ATTENTION FOR THE SAFETY OF THE PEOPLE IT IS IMPORTANT TO FOLLOW ALL THE INSTRUCTIONS FOLLOW ALL INSTALLATION INSTRUCTIONS d 29 3 4 5 6 This handbook is exclusively addressed to the specialized personnel who knows the constructive criteria and the protection devices against the accidents for motorized gates doors and main doors follow the standards and the laws in force The installer will have to issue to the final user a handbook in accordance with the EN 12635 Before proceeding with the installation the installer must forecast the risks analysis of the final automatized closing and the safety of the identified dangerous points following the standards EN 12453 EN 12445 The wiring harness of the different electric components external to the operator for example photoelectric cells flashlights etc must be carried out according to the EN 60204 1 and the modifications to it done in the point 5 2 2 of the EN 12453 The possible assembly of a keyboard for th
103. ms Potenza massima gestibile all uscita del motore 10V Carico massimo all uscita del lampeggiatore 40W con carico resistivo Assorbimento massimo scheda esclusi accessori 33mA Corrente disponibile per le fotocellule 0 4 15 24Vdc Grado di protezione IP54 Peso apparecchiatura 0 55 kg Ingombro 130 x 50 x 115mm CARATTERISTICHE TECNICHE RADIO solo modelli CRX Frequenza Ricezione 433 92MHz Impedenza 520 Sensibilita gt 2 24 Tempo eccitazione 300ms Tempo diseccitazione 300ms DIFETTO Codici memorizzabili N 60 30 per apertura totale e 30 per apertura pedonale Corrente disponibile su connettore radio 200mA 24Vdc Tutti gli ingressi devono essere utilizzati come contatti puliti perch l alimentazione generata internamente alla scheda ed disposta in modo da garantire il rispetto di isolamento doppio o rinforzato rispetto alle parti in tensione Tutti gli ingressi vengono gestiti da un circuito integrato programmato che esegue un autocontrollo ad ogni avvio di marcia RISOLUZIONE PROBLEMI Dopo aver effettuato tutti i collegamenti seguendo attentamente lo schema ed aver posizionato il cancello in posizione intermedia verificare la corretta accensione dei led DL3 DL4 DL7 DL8 In caso di mancata accensione dei led sempre con cancello in posizione intermedia verificare quanto segue e sostituire eventuali componenti guasti 03 spento Finecorsa ferma apertura guasto 014 spento Finecorsa ferma chiusura
104. n Antrieb mt seinen kinetischen und statischer Groesse zum halten bringt 12 Abb 2 Es ist notwendig am Ende der Fihrung zwei mechanische Stoppvorrichtungen zu befestigen 12 Abb 2 Die Tors ulen missen oben Vorrichtungen gegen ein Entgleisen besitzen Abb 3 um unfreiwilliges Aushaken zu vermeiden ANMERKUNG Die in Abb 3 beschriebenen mechanischen Anschl ge entfernen Es dilrfen keine mechanischen Anschl ge ber dem Tor vorhanden sein da diese nicht ausreichend sicher sind 50 min Komponenten zur Installation nach der Norm EN1253 ANWENDUNG DER SCHLIESSUNG Fachpersonen STEUERUNGSSYSTEM enem Chpersonen Grenzlose A ffentlicher ffentlichen Anwendung Platz Platz mit Totmannschaltung A B nicht m glich TESI DOE C oder E C oder E C und D oder E z B Sensor mit nicht sichtbaren C oder E C und D oder E C und D oder E Impulsen Fernsender automatisch C und D oder E C und D oder E oder E ein Musterbeispiel daf r sind jene T re die keine Zufahrt zu einem ffentlichen Weg haben Betriebstaste mit Totmannschaltung das hei t aktivieren sie eine Funktion solange man sie gedr ckt h lt wie Kode ACG2013 B Schl sselselektor mit Totmannschaltung wie Kode ACG1010 C Justierbare Kraft des Motors D Kontaktleiste und oder andere Sicherheitseinrichtungen muessen mit den Norm EN12453 uebereinstimmen Anhang A E Photozelle wie Kode ACG8026 Jed
105. n modo indipenden rettiva 2006 42 CE Macchine e successive modifiche per cui segnaliamo il divieto di messa in servizio prima che l impianto sia stato dichiarato conforme alle disposizioni della Direttiva DI Le pr sent dispositif ne peut fon de l art 6 paragraphe 2 de la aux dispositions pr vues par la T his produc ieses Prod nter Artikel Este produc de la Dispo conforme a can not work alone and was designed to be fit Machines and following modi ukt kann nicht allein 6 Paragraph 2 der EWG Richtlinie 2006 42 Maschinen und folgen o no puede funcionar de manera independiente y se tiene que incorporar en una instalaci n compuesta por otros elementos Est incluido por lo sici n 2006 42 CEE Maquinaria y sus siguientes modificaciones por lo cual destacamos que est prohibido poner la instalaci n en marcha antes de que est declarada a citada Disposici n e ed destinato ad essere incorporato in un impianto costituito da ulteriori elementi Rientra perci nell Art 6 paragrafo 2 della ctionner de mani re ind pendante tant pr vu pour tre int gr une installation constitu e d autres l ments Aussi rentre t il dans le champ d application Directive machines 2006 42 CEE et de ses modifications successives Sa mise en service est interdite avant que l installation ait t d clar e conforme Directive up of various other elements Hence it falls within Article 6 Paragraph
106. nalizar la programaci n dejar transcurrir 10 segundos o bien presionar por un instante el pulsador PROG El led rojo DL1 de programaci n deja de parpadear 6 Volver a colocar el DIP1 en posici n OFF y el DIP 3 en OFF NOTA SI EL LED DL1 CONTIN A PARPADEANDO VELOZMENTE SIGNIFICA QUE EL DIP1 SE ENCUENTRA A N EN POSICI N ON Y NO SE PUEDE LLEVAR A CABO NINGUNA MANIOBRA 7 Final del procedimiento PROCEDIMIENTO PARA LA CANCELACI N DE TODOS LOS C DIGOS DE RADIO DESTINADOS A LA APERTURA PEATONAL La cancelaci n puede ser efectuada nicamente con la cancela detenida 1 Colocar el DIP 1 en posici n ON y sucesivamente el DIP 3 en ON 2 El led rojo DL1 de programaci n parpadea con una frecuencia de 1 seg ON y 1 seg OFF durante 10 segundos 3 Presionar y mantener presionado el pulsador PROG durante 5 segundos La cancelaci n de la memoria es indicada mediante dos parpadeos del led verde DL2 4 EL led rojo DL1 de programaci n permanece activo y es posible introducir nuevos c digos siguiendo los procedimientos arriba descritos 5 Volver a colocar el DIP 1 en posici n OFF y DIP 3 en OFF 6 Final del procedimiento SE ALIZACI N DE MEMORIA LLENA C DIGOS DE RADIO DESTINADOS A LA APERTURA PEATONAL La se alizaci n se puede obtener nicamente con la cancela detenida 1 Colocar el DIP 1 en posici n ON y sucesivamente el DIP 3 en ON 2 El led verde DL2 parpadea 6 veces indicando que la memoria est saturada 30
107. ner les cames de fin de course Porter le portail mi course et bloquer l op rate 2 Placer le sur ON gt le voyant lumineux 011 commencera clignoter 3 Appuyer et maintenir enfonc le bouton PROG le mouvement est effectu homme pr sent ouvre stop ferme stop ouvre etc gt le LED VERT DL6 OPEN s allume et le portail doit s ouvrir dans le cas contraire rel cher le bouton PROG et intervertir les fils du moteur V et W et il doit s arr ter ensuite au contact avec le fin de course lectrique si cela ne se produit pas rel cher le bouton PROG et intervertir les deux fils du fin de course LSO et LSC 4 Appuyer sur le bouton PROG et le maintenir enfonc gt le LED ROUGE DL5 CLOSE s allume et le portail doit se fermer et s arr ter ensuite au contact avec le fin de course lectrique 5 Apr s 2 sec et jusqu 10 sec cons cutives de travail en ouverture ou fermeture l embrayage lectronique se d clenche automatiquement ex cuter le r glage de l embrayage lectronique en agissant sur le trimmer TORQUE 6 Apr s 10 sec cons cutives de travail en ouverture ou en fermeture le ralentissement se d clenche automatiquement si DIP 8 OFF ex cuter le r glage de la vitesse ralentie en agissant sur le trimmer LOW SPEED et en choisissant la vitesse d sir e 7 A la fin du contr le et des r glages des trimmers remettre en position OFF Le led DL1 s teint en signalant la sortie d
108. ng Maximum load of radio receiver output 200mA 24Vdc All inputs shall be used as clean contacts without earthing because the power supply is generated in the card and is structured in such a way to guarantee the respect of double and reinforced insulation to the elements under voltage All inputs are managed by a programmed circuit that carries out a self control every time the gate is operated TROUBLESHOOTING After having carried out all connections by carefully following the layout and having positioned the gate in intermediate position check the correct ignition of LEDS DL3 DL4 DL7 DL8 In case of no ignition of the LEDS always with gate in intermediate position check the following and replace any faulty components DL3 switched off Faulty opening limit switch DLA switched off Faulty closing limit switch DL7 switched off Faulty photocells DL8 switched off Faulty safety edge In case the edge is not connected carry out jumper between COM and EDGE During functioning with personnel present with DIP 1 at ON check that during opening the green DL6 LED switches on and that during closing the red DL5 LED switches on If not invert clamps V and W on the motor terminal board SOLUTION After having carried out the various connections and having supplied voltage all the LEDS Check the integrity of fuses F1 and F2 In case of interrupted fuse use only of adequate value are switched off The motor opens and
109. ngono inibite tutte le funzioni di comando Al rilascio dell interruttore 0 allo scadere dell ora impostata si avr la chiusura immediata dell automazione PULSANTE APERTURA PEDONALE COM PED BUTTON Comando dedicato ad un apertura parziale e alla sua richiusura Durante l apertura la pausa o la chiusura pedonale amp possibile comandare l apertura da qualsiasi comando collegato sulla scheda Tramite DIP 6 possibile scegliere la modalit di funzionamento del pulsante di comando pedonale Se DIP6 su ON gt Esegue un comando ciclico dei comandi apre stopchiude stop ecc Se DIP6 su OFF gt Esegue l apertura a cancello chiuso Se azionato durante il movimento di apertura non ha effetto Se azionato a cancello aperto pedonale lo chiude e durante la chiusura se azionato lo fa riaprire TELECOMANDO sia per apertura totale che pedonale Se DIP6 su ON gt Esegue un comando ciclico dei comandi apre stop chiude stop apre etc Se DIP6 su OFF gt Esegue l apertura a cancello chiuso Se azionato durante il movimento di apertura non ha effetto Se azionato con cancello aperto lo chiude e durante la chiusura se azionato lo fa riaprire CHIUSURA AUTOMATICA CON APERTURA TOTALE tempi di pausa prima di avere la chiusura automatica in apertura totale del cancello vengono registrati durante le programmazioni dei tempi empo di pausa massimo e di 5 minuti tempi di pausa sono attivabili o disattivabili tramite DIP3 ON attivo CHIUSU
110. o de espera antes del cierre autom tico m x 5 minutos 4 Una vez alcanzado el final de carrera de cierre la cancela se para 5 AL FINAL DE LA PROGRAMACI N VOLVER A PONER EL DIP 2 EN OFF NOTA La deceleraci n es determinada autom ticamente por la central en fase de programaci n de los tiempos y se activa a 50 60 cm antes de alcanzar el final de carrera de abertura o de cierre Esta medida puede variar ligeramente seg n la temperatura D PROGRAMACI N DE TIEMPOS DE ABERTURA PEATONAL Con la cancela cerrada 1 Poner primero el DIP2 en ON el led DL1 parpadea r pidamente y luego el DIP1 en ON el led DL1 parpadea lentamente 2 Presionar el pulsador peatonal COM PED BUTT gt la cancela abre Presionar el pulsador peatonal para detener la carrera definiendo de esta manera la abertura de la cancela 4 Esperar el tiempo que se desea permanezca abierta se puede excluir con el DIP3 en OFF luego presionar el pulsador peatonal para iniciar el cierre 5 AL FINAL DE LA PROGRAMACI N PEATONAL REPOSICIONAR LOS DIP 1 Y 2 EN OFF DURANTE LA PROGRAMACI N LAS PROTECCIONES PERMANECEN ACTIVADAS Y SU INTERVENCI N DETIENE LA PROGRAMACI N EL LED DL1 DE INTERMITENTE PASA A ENCENDIDO FIJO PARA REPETIR LA PROGRAMACI N POSICIONAR EL DIP 2 EN OFF CERRAR LA PUERTA POR MEDIO DEL PROCEDIMIENTO CONTROL DEL SENTIDO DE ROTACI N DEL MOTOR Y REPETIR LA PROGRAMACI N ANTES DESCRITA E PROGRAMACI
111. or periodisch von Steinen und anderen Verunreinigungen s ubern E A at E ds KR wi _ 233 25 Abmessungen mm 6 233 Abmessungen in on D ELEKTROANSCHL SSE oo RSS ANTENNE SPEISUNG SPARK 230Vac 50 Hz 230Vac 40W Jal FAN Gy sue FUSSG NGER BUZZER csi SCHRITT BEI SCHRITT MECHANISCHE RIPPE FOTOZELLEN ZUBEH RE B e AUTOTEST F R GELENKRIPPE 24Vdc 0 4A x 15 24Vdc 0 4A x 15 SCHRITT BEI SCHRITT FUSSG NGER BLOCK SCHLUSSELWAHLER UND SCHALTFELD FLAT FOTOZELLEN FIT SLIM MECHANISCHE RIPPE 36 A VERBINDUNGEN Ji no cax BER HREN SIE NICHT DEN JUMPER WENN ER ENTFERNT gero WIRD ZIEHT DER OPERATOR NICHT UM J2 AERIAL Radioantenne LSC Endschalterkontakt der das SchlieBen stoppt LSO Endschalterkontakt der das ffnen stoppt COM Gemeinsame Erdungskontakte PED BUTT Kontaktbefehl f r FuBg nger J3 L N Stromversorgung 230Vac 50 60 Hz auf Antrag 120V 60Hz J4 ERDEN Anschluss der Erdleitungen obligatorisch J5 RADIO Konnektor f r externen Radioempf nger 24Vdc Modelle mit CRX Radio Modul eingebaut Modelle CRX J6 A TEST Positiv f r die Speisung Autotest Rippe zu 24Vdc A Positiv f r die Speisung der Zubeh re zu 24Vdc A Negativ f r die Speisung der Zubeh re zu 24Vdc COM Gemeinsame Erdungskontakte POSITIV K BUTT Kontakt Einzelimpuls NO PHOT Fotoze
112. ortail est ferm Si ce poussoir est actionn au cours du mouvement d ouverture du portail son effet est nul S il est actionn lorsque le portail est ouvert il le referme S il est actionn au cours du mouvement de fermeture du portail il le rouvre FONCTION HORLOGE Pour utiliser la FUNCTION HORLOGE demander K2007 avec firmware 12 NOUP ATTENTION UNE HORLOGE CONNECT K2007 avec fw 05 ou plus ACTIVE LE MOUVEMENT AUTOMATIQUE DE PORTAIL SANS S CURIT ACTIVE Cette fonction est tr s utile pendant les heures de pointe lorsque la circulation des v hicules est ralentie par exemple entr e sortie des ouvriers urgences dans les r sidences ou dans les parkings et si besoin pour les d m nagements MODALIT D APPLICATION FONCTION HORLOGE Demander K2007 avec firmware 12 NOUP S lectionnez fonctionnement automatique DIP 6 OFF En connectant un interrupteur et ou une horloge de type journalier hebdomadaire la place ou en parall le au poussoir d ouverture n a COM K BUTTON il est possible d ouvrir ou de maintenir l automation ouverte tant que l interrupteur reste enfonc ou tant que l horloge est active Tant que l automation est ouverte toutes les fonctions de commandes sont inactives Quand on rel che l interrupteur ou lorsque l heure ins r e est chue on aura la fermeture imm diate de l automation BOUTON OUVERTURE PIETONNE COM PED BUTTON Commande d di e une ouverture par
113. pe ada por mas de 60 segundos los comandos K BUTTON y el PEATONAL funcionar n solo a hombre presente El signal de activaci n de este funcionamiento ser indicado por el LED de programacion que relampaguea En este funci n ser aconsentido el apertura y el cierre solo manteniendo apretados los pulsadores de comandos El comando radio y el cierre automatico ser n excludidos porque estas formas de funcionamientos no son permitidas por las normas Una vez que los accesorios de seguridad ser n reparados o vuelven a funcionar corectamente despues de 1 segundo en automatico el comando paso paso y el automatico pueden funcionar normalmente por lo tanto sea el comando radio de los transmisores y el cierre automatico pondr n funcionar como programado Nota 1 durante el funcionamiento a hombre presente las fotocelulas y los burletes de seguridad que no tienen averias pueden parar el movimiento del port n La maniobra a hombre presente es exclusivamente una maniobra de emergencia y por lo tanto se debe utilizar por un tiempo muy corto y con la seguridad visiva sobre el movimiento del sistema No apenas posible se deber que reparar los accesorios de seguridad por un corecto funcionamiento S i INTERMITENTE IMPORTANTE Este cuadro electr nico es compatible SOLAMENTE CON FAROS CON CIRCUITO INTERMITENTE ACG7059 con bombillas de m ximo 40W FUNCI N DE PRE DESTELLO Con DIP5 en OFF gt el motor el intermitente y el avisador ac st
114. peggiare Riposizionare DIP 1 su OFF e DIP 3 su OFF NOTA SE IL LED DL1 CONTINUA A LAMPEGGIARE VELOCEMENTE SIGNIFICA CHE IL DIP 1 RISULTA ANCORA POSIZIONATO IN ON E QUALSIASI MANOVRA VIENE NEGATA Fine procedura PROCEDURA CANCELLAZIONE DI TUTTI I CODICI RADIO DEDICATI ALL APERTURA PEDONALE La cancellazione pu essere eseguita solo a cancello fermo je dc 3 4 5 6 Posizionare il DIP 1 su ON e successivamente il DIP 3 su ON led rosso DL1 di programmazione lampeggia con frequenza di 1 sec ON e 1 sec OFF per 10 secondi Premere e mantenere premuto il pulsante PROG per 5 secondi La cancellazione della memoria viene segnalata da due lampeggi del led verde DL2 led rosso DL1 di programmazione rimane attivo ed possibile inserire nuovi codici come da procedure sopra descritte Riposizionare DIP 1 su OFF e DIP 3 su OFF Fine procedura SEGNALAZIONE MEMORIA SATURA CODICI RADIO DEDICATI ALL APERTURA PEDONALE La segnalazione si pu ottenere solo a cancello fermo 10 1 Posizionare il DIP 1 su ON e successivamente il DIP 3 su ON 2 Il led verde DL2 lampeggia per 6 volte segnalando memoria satura 30 codici presenti 3 Successivamente il led DL1 di programmazione rimane attivo per 10 secondi consentendo un eventuale cancellazione totale dei codici 4 Riposizionare DIP 1 su OFF e DIP 3 su OFF 5 Fine procedura FUNZIONAMENTO ACCESSORI DI COMANDO ATTENZIONE COLLEGARE ACCESSORI DI COMA
115. pment The test is performed every time the gate completes a full opening The test is available only if the safety strip device is equipped with a dedicated power supply input In fact the safety strip equipment power supply input can be connected to the A TEST and A outputs DIP10 ON Automatically every time the gate completes a full opening ju before closing the control board switches OFF the A TEST and A power supply output for a very short time While the safety strip power supply is switched OFF if everything is working fine the safety strip contact EDGE COM must open In case the test fails no other gat manoeuvre will be allowed and the alarm state will be signalled by both the Blinker and th Buzzer if installed which will remain on for 5 minutes NOT ALL THE SAFETY STRIPS CAN BE TESTED THUS THE SWITCH DIP10 MUST BE LEFT OFF 77 e e STOP BUTTON If the Automatic command is enabled DIP 6 OFF a Normally Closed contact could be connected in series to the COM wire of the opened and the closed limit switches This contact works like a STOP button to interrupt any gate manouver FUNCTIONING IN DEAD MAN MODE WHEN THE SAFETY DEVICES ARE FAILING If the safety edge fails or remains engaged for more than 5 seconds or if photocell fails or emain engaded for more than 60 seconds the K BUTTON and PEDESTRIAN commands will work only in dead man mode The signal that this mode has been activated is g
116. po M6 El engranaje de arrastre tiene que tener una holgura de alrededor de 1 mm respecto a la cremallera i HART wo Ba S T Y 0 N N gt Medidas en mm 5 FIJACION FINAL DE CARRERA Para determinar el recorrido de la parte m vil se tiene que colocar dos limitadores de recorrido en los extremos de la cremallera Fig 9 La regulaci n de la abertura y el cierre se obtiene desplazando la misma sobre los dientes de la cremallera Para fijar las limitadores de tope de recorrido a la verja atornillar a fondo los tornillos suministrados N B adem s de los citados limitadores de recorrido el ctricos es obligatorio instalar unos topes mec nicos resistentes que impidan la salida del la verja de las gu as superiores MANTENIMIENTO Tiene que ser efectuado solamente por personal especializado tras haber cortado la alimentaci n el ctrica al motor Limpiar peri dicamente con la verja parada la gu a de deslizamiento de eventuales piedras u otras suciedades 233 25 Medidas en mm 6 233 2545 Medidas en mm 7 4 CONEXIONES EL CTRICAS pr ANTENA ALIMENTACI N SPARK 230Vac 50 Hz 230Vac 40W PEATONAL BUZZER csi COMUN PASSO PASSO COSTA MEC NICA FOTOC LULAS um ACCESORIOS AUTOTEST PARA COSTA 24Vdc 0 4A x 15 24Vdc 0 4A x 15 PASSO PASSO PEATONAL SELECTORES CON LLAVE BLOCK Y BOTONERA F
117. que dar al utilizador final un manual de instrucciones de acuerdo con la EN 12635 3 El instalador antes de proceder con la instalaci n tiene que hacer una analisis de los riesgos del cierre automatizado final y la puesta en seguridad de los puntos identificados como peligrosos siguiendo las normas EN 12453 EN 12445 4 El cablaje de los varios componentes el ctricos externos al operador por ejemplo fotoc lulas los intermitentes etc tiene que ser efectuado seg n la EN 60204 1 y a las modificas sucesivas aportadas por el punto 5 2 2 della EN 12453 5 El eventual montaje de un panel de mandos para la gesti n del movimiento manual tiene que ser efectuado posicionando el panel en modo que qui n lo accione no se encuentre en una posici n peligrosa adem s se tiene que hacer en modo que el riesgo de accionamiento accidental de los pulsadores sea m nimo 6 Tener los mandos del automatismo panel de mandos mando a distancia etc lejos del alcance de los ni os Los mandos tienen que ser puestoa una altura m nima de 1 5mt del suelo y fuera del radio de acci n de las partes m viles 7 Antes de ejecutar cualquier operaci n de instalaci n ajuste o mantenimiento del sistema quitar la corriente accionando el respectivo interruptor magnetot rmico conectado antes del mismo LA EMPRESA RIB NO ES RESPONSABLE por eventuales da os provocados por la falta de respeto de las normas de seguridad durante la instalaci
118. r f r Fu g nger in Betrieb gesetzt wird sich dieses schlie en und w hrend der Schlie fase wird das Tor sich wieder erneut ffnen wenn ein Impuls erfolgt FERNSENDER F R GESAMT FFNUNG UND FUSSG NGER FFNUNG Wenn DIP6 auf ON steht gt F hrt einen Befehl der Steuerreihe ffnen Stop Schlie en Stop ffnen usw aus Wenn DIP6 auf OFF steht gt F hrt die ffnung des geschlossenen Tors aus Wenn diese Taste w hrend der ffnungsbewegung bet tigt wird hat sie keine Auswirkung Wird sie bei ge ffnetem Tor bet tigt wird das Tor geschlossen Wenn diese Taste w hrend der Schlie bewegung bet tigt wird wird das Tor erneut ge ffnet AUTOMATISCHE SCHLIESSUNG bei Fu g nger ffnung oder Normal ffnung Die maximale Pausenzeit bevor sich das Tor wieder von allein schlie t betr gt 5 Minuten Die Pausenzeit k nnen Sie deaktivieren wenn Sie den DIP 3 in Position OFF stellen in Position ON ist sie Aktiv AUTOMATISCHE SCHLIESSUNG MIT FFNUNG F R FUSSG NGER Die Pausenzeiten vor der automatischen Fu g nger Torschlie ung werden w hrend der Programmierung Fu g nger registriert Die maximale Zeit betr gt 5 Minuten Die Pausenzeit kann durch DIP3 ON aktiv aktiviert oder ausgeschaltet werden FUNKTIONSWEISE DES SICHERHEITSZUBEH RS FOTOZELLE COM PHOT Wenn DIP 4 auf Off steht gt Wenn sich bei geschlossenem Tor ein Hindernis imStrahlenbereich der Fotozelle befindet ffnet sich das Tor nich
119. ra le colonne ed all interno per tutta la corsa della parte mobile ogni 60 70 per tutta l altezz un massimo di 2 5m EN 12445 punto 7 3 2 1 es colonne alte 2 2mt gt 6 coppie di fotocellule 3 interne e 3 esterne meglio se dotate di sincronismo 6 FIT SYNCRO con 2 TX SYNCRO a delle colonne del cancello fino ad N B obbligatoria la messa a terra dell impianto I dati descritti nel presente manuale sono puramente indicativi RIB si riserva di modificarli in qualsiasi momento Realizzare l impianto in ottemperanza alle norme ed alle leggi vigenti INSTRUCTIONS DE SECURITE IMPORTANTES POUR L INSTALLATION ATTENTION POUR LA SECURITE DES PERSONNES IL EST IMPORTANT QUE TOUTES LES INSTRUCTIONS SOIENT SUIVIES SU js Ss ge 4 5 6 IVRE TOUTES LES INSTRUCTIONS D INSTALLATION Ce livret d instructions est adress exclusivement un personnel sp cialis qui conna t les crit res de construction et les dispositifs de protection contre les accidents concernant les portails les portes et les grandes portes motoris s s en tenir aux normes et aux lois en vigueur L installateur devra d livrer l utilisateur final un livret d instruction en accord a EN 12635 L installateur avant de proc der l installation doit pr voir l analyse des risques de la fermeture automatis e finale et la mise en s curit des points identifi s dangereux en suivant les normes EN 12453 EN 124
120. rogrammierung kann nur bei stillstehendem Tor vorgenommen werden 1 Zuerst DIP 1 und danach DIP 3 auf ON stellen 2 LED DU rot f r die Programmierung blinkt im Abstand von 1 Sekunde bei ON und 10 ekunden bei OFF ie Taste der Fernsteuerung gew hnlich Kanal B innerhalb der eingestellten Zeit von 0 Sekunden dr cken Bei korrekter Speicherung der Fernsteuerung leuchtet das LED L2 gr n auf e Zeit f r die Programmierung der Codes wird automatisch erneuert damit die n chste Fernsteuerung gespeichert werden kann 5 F r die Beendigung der Programmierung 10 Sekunden verlaufen lassen oder f r einen Augenblick die Taste PROG dr cken Das rote LED DL1 f r die Programmierung h rt auf zu blinken 6 DIP 1 und DIP 3 erneut auf OFF stellen ANMERKUNG WENN LED DLA WEITER SCHNELL BLINKT SO BEDEUTET DAS DASS DIP 1 NOCH AUF ON GESTELLT IST IN DIESEM FALL WIRD JEGLICHER VORGANG VERWEIGERT 7 Ende des Vorgangs L SCHUNG ALLE FUNKCODES F R DIE FUSSGANGEROFFNUNG Die L schung kann nur bei stillstehendem Tor vorgenommen werden 1 Zuerst DIP 1 und danach DIP 3 auf ON stellen 2 LED DU rot f r die Programmierung blinkt im Abstand von 1 Sekunde bei ON und 10 Sekunden bei OFF 3 Die Taste PROG dr cken und 5 Sekunden eingedr ckt halten Die L schung des Speichers wird durch zwei Blinker des gr nen LEDs DL2 angezeigt 4 Das rote LED DL1 f r die Programmierung bleibt aktiviert und man kann neue Codes eingeben
121. shing the FLASHING LIGHT the BUZZER and the motor will start at the same time BUZZER COM BUZZER The current supplied to the Buzzer will be 200 mA at 24Vdc During the normal operation of the gate opening and closing the buzzer will buzz ntermittently Only during the alarm situations safety strip the buzzing will almost be constant GATE OPEN INDICATOR A negativo LSC It is turned ON when the gate is open or partially open it is turned OFF only when the gate is completely closed connect in series to the indicator a resistance of 2K2 WE RECOMMEND NOT TO OVERLOAD THE INDICATORS OUTPUT OTHERWISE THE GATE FUNCTIONING COULD BE COMPROMISED OR THE CONTROL BOARD COULD BE DAMAGED TECHNICAL SPECIFICATIONS Humidity lt 95 without condensation Power supply voltage 230V 10 120V 60Hz upon request Frequency 50 60 Hz Interruptions in electricity supply 20ms FAULT Maximum load of motor outputs 1CV Maximum load of blinker output with resistive load 40W Maximum control board absorption without accessories 33 mA Current available for photocells and accessories 0 4A 15 24Vdc IP protection grade IP54 Control board weight 0 55 kg Dimensions 130 x 50 x 115 mm TECHNICAL RADIO SPECIFICATIONS model CRX Reception frequency 433 92MHz Impedance 520 Sensitivity gt 2 24uV Time of excitation 300ms Time of discharge 300ms Memory available 60 codes 30 for complete opening and 30 for pedestrian openi
122. siehe die vorhergehende Beschreibung 5 DIP 1 und DIP 3 erneut auf OFF stellen 6 Ende des Vorgangs co gs oO 4 40 ANZEIGE SPEICHER FUNKCODES F R FUSSG NGER FFNUNG Die Anzeige kann nur bei stillstehendem Tor erfolgen 1 Zuerst DIP 1 auf ON und danach DIP 3 auf ON stellen 2 Das gr ne LED 012 blinkt 6 Mal und zeigt dass der Speicher voll ist 30 Codes vorhanden 3 Danach bleibt das LED DL1 f r die Programmierung f r 10 Sekunden aktiviert und erm glicht eine eventuelle Gesamtl schung der Codes 4 DIP 1 und DIP 3 erneut auf OFF stellen 5 Ende des Vorgangs FUNKTIONSWEISE DES STEUERZUBEH RS WARNUNG VERBINDEN SIE STEUERUNG ZUBEH R NUR WENN ES AUF IMPULS MODUS Stellen Sie sicher dass alle anderen Arten von Steuerung Zubeh r z B Magnetsensoren auf IMPULS Modus programmiert ist da es die Bewegung des Tores ohne aktive Sicherheiten aktiviert BEDIENUNGSSCHALTER COM K BUTTON Wenn DIP6 auf ON steht gt F hrt einen Befehl der Steuerreihe ffnen Stop Schlie en Stop Offnen usw aus Wenn DIP6 auf OFF steht gt F hrt die ffnung des geschlossenen Tors aus Wenn diese Taste w hrend der ffnungsbewegung bet tigt wird hat sie keine Auswirkung Wenn sie bei offenem Tor bet tigt wird wird das Tor geschlossen Bet tigung w hrend dem Schlie en f hrt zum erneuten ffnen FUNKTION UHR Wenn Sie die Uhr Funktion wollen m ssen Sie f r
123. stall a thermal magnetic switch omnipolar with a minimum contact opening of 3 mm before the control board in case this is not provided with it The switch shall be guaranteed by a mark of compliance with international standards Such a device must be protected against accidental closing e g Installing it inside the control panel key locked container As far as the cable section and the cable kind are concerned RIB suggests to use an HO5RN F cable with a minimum section of 1 5mm2 and to follow In any case the IEC 364 standard and Installation regulations In force In your Country Positioning of an eventual pair of photocells The beam of the photocells must be at an height not above the 70 cm from the ground and should not be more than 20 cm away from the axis of operation of the gate Sliding track for sliding gate or door and the hinges for the swing gate In accordance with the point 7 2 1 of EN 12445 their correct functioning must be checked once the whole installation has been completed In order to comply with the limits defined by the EN 12453 norm if the peak force is higher than the limit of 400N set by the norm it is necessary to use an active obstacle detection system on the whole height of the gate up to a maximum of 2 5m The photocells in this case must be apply externally between the colums and internally for all the race of the mobil part every 60 70cm for all the height of the column of the gate up to a maximum of 2 5m
124. stellbare Reichweite 10 20m Dank einer Synchronisiereinrichtung sind mehrere sich gegenseitig ann hernde Paare m glich Bei mehr als 2 Fotozellenpaare bis 4 den SENDER SYNCRO mit Kode ACG8028 hinzuf gen ACG8028 f r mehr als 2 Fotozellenpaare bis 4 Paare PAAR F R EINBAUKASTEN F R FITSYNCRO Kode ACG8051 FERNSENDER SUN SUN 2CH Kode ACG6052 SUN ACH Kode ACG6054 SUN CLONE 2CH Kode ACG6056 SUN CLONE 4CH Kode ACG6058 Wi Fi VORRICHTUNGEN MASTER Wi Fi KARTE F R DEN BETRIEB DES SYSTEMS OHNE KABEL mit Verbinder 12 30V ac dc Kode ACG6094 mit Endblockierung 12 30V ac dc Kode ACG6099 NOVA Wi Fi FOTOZELLEN OHNE KABEL Kode ACG8037 EIN PAAR FOTOZELLEN ST NDER NOVA Kode ACG8039 CODESCHLOSS BER FUNK Unterputz Kode ACG9434 Wandbefestigung Kode ACG9436 BLOCK Wi Fi SCHL SSELSCHALTER OHNE KABEL Kode ACG6098 VERTIGO Wi Fi TOUCH Wi Fi KABELLOSE FOTOZELLE ERSETZT DIE KONTAKTLEISTE OHNE KABEL SCHALTLEISTEN Kode ACG3016 VERTIGO Wi Fi 8 Kode ACG8042 VERTIGO Wi Fi 10 Kode ACG8043 RADIO SENDER RED F r mechanische oder elektrische Kontaktleiste Versorgung mit Mignon Batterien vom Typ AA zu 1 5V nicht im Lieferumfang enthalten RED erlaubt die Realisierung einer Anlage mit Kontaktleisten die auch auf dem sich bewegenden Tor angebracht sein k nnen ohne dass man Kabelsammelsysteme ben tigt Entspricht der Norm EN13849 1 2007 und in Verbindung mit einer RIB Schalttafel stellt es eine Schutzvorrichtung
125. sur l engrenage de traction du K500 Fig 5 et 6 Pour fixer la cr maill re sur le portail il suffit de faire des trous de 5 mm et de les tarauder en se servant d un araud du type M6 L engrenage d entra nement doit disposer d environ 1 mm de rayon d action par rapport la cr maill re Eu O O E s 85 05 TU KS gt 223 30 Mesures en mm 5 FIXATION FIN DE COURSE Pour d terminer la course de la partie mobile il faut positionner deux cames sur les extr mit s de la cr maill re Fig 9 Pour proc der au r glage de la course d ouverture et de fermeture il suffit de d placer les cames sur les crans de la cr maill re Pour bloquer les cames sur la cr maill re visser fond les vis fournies avec l quipement N B En plus des cames d arr t lectrique susmentionn es il est indispensable d installer des arr ts m caniques solides qui emp cheront le portail de sortir des glissi res sup rieures ENTRETIEN Toutes les op rations d entretien devront tre effectu es exclusivement par du personnel sp cialis et apr s avoir mis le moteur hors tension Nettoyer p riodiquement la glissi re en enlevant tous les cailloux ou toute autre salet qui pourraient s y trouver Cette op ration doit tre effectu e lorsque le portail est arr t 111 233 25 Mesures en mm 6 233 2545 Mesures en mm 7 BRANCHEMENTS LECTRIQUES Ee ANTENNE ALIMENTATION SPAR
126. swing open the leaf about halfway and lock the operator 2 Turn to ON position LED DL1 starts blinking 3 Press and hold the PROG button the gate will open or close Release the button and the gate will stop Press and hold again the gate will move in the opposite direction The K control board has two movement leds DL6 the GREEN led for OPENING DL5 the RED led for CLOSING When you press and hold the PROG button if the gate opens with the green led on then you may proceed to step 4 If the gate moves in the wrong direction compared with the movement leds urn OFF the main AC power reverse the V and W motor cables position the blue motor cable must be always in the U position reverse the limit switch wires marked LSO and LSC urn ON the main AC power and check again the motor direction 4 After 2 seconds motor starting and for the next 10 seconds motor working the torque control is automatically activated Set the motor torque by the TORQUE Trimmer which varies the output voltage to the head of the motor turn clockwise to increase torque 5 After other 10 seconds motor working the low speed control is automatically activated DIP8 OFF Set the motor low speed by the LOW SPEED Trimmer to select the gate leaf low speed in approaching 6 Press and hold the PROG button to close completely the gate Turn DIP1 to OFF the RED led DL1 will stop blinking During Point C procedure s
127. t W hrend dem Betrieb berwachen die Fotozellen sowohl das ffnen mit Wiederanlauf des Motors zum ffnen nach einer halben Sekunde als auch das Schlie en mit Wiederanlauf des Umkehr Motors nach einer Sekunde Wenn DIP 4 auf On steht gt Wenn sich bei geschlossenem Tor ein Hindernis im Strahlenbereich der Fotozelle befindet und die ffnung befohlen ist ffnet sich das Tor w hrend der ffnung sind die Fotozellen funktionslos Die Fotozellen schreiten nur in der Schlie phase ein mit Wiederanlauf des Umkehr Motors nach einer Sekunde auch wenn die Fotozellen in Funktion bleiben ZU BEACHTEN wird dieser Zugang nicht genutzt eine berbr ckung mit den Klemmen COM PHOT ausf hren PNEUMATIK MECHANISCHE KONTAKTLEISTE ODER FOTORIPPE COM EDGE Wenn es bei der Er ffnung arbeitet kehrt die Schlie bewegung f r 2 Sekunden und stoppt dann Wenn es bei der Schlie bewegung arbeitet kehrt die ffnung f r 2 Sekunden und stoppt dann Bleibt die Kontaktleiste eingeschaltet Kontakt NO ist keinerlei Automatische Bewegung m glich Wird sie nicht benutzt die Klemmen COM EDGE berbr cken Hinweis Es wird empfohlen die Funktionsweise der Kontaktleisten mindestens alle 6 Monate zu berpr fen ALARM KONTAKTLEISTEN Nach einer Umkehr der Ausl sung der Kontakleiste verursacht h lt das Tor den Alarmzustand von dem Blinklicht f r 1 Minute und von dem Buzzer f r 5 Minuten signalisiert W hrend oder nach der Min
128. t is possible to obtain the special to type plate for type K500 code ACG8108 to be secured directly to the floor In addition it is possible to install the equipment K500 complete with base plate directly over the installation plate as suitable for operator K5 code ACG8101 The base plate for operator K500 features four holes for floor securing through four expansion studs The rack shall be fitted over the motor support at a certain distance from it Its height can be adjusted thanks to the holes In the rack The height is adjusted to prevent the gate from resting on the driving gear of the K as it moves Fig 5 6 To fix the rack on the gate drill some 5 mm holes and thread them using an 6 screw tap The driving gear needs some 1 mm clearance from the rack Measurements in mm LIMIT SWITCH FITTING In order to determine the travel of the moving part place two cams at the ends of the rack Fig 9 Move the cams on the rack teeth to adjust their opening and closing travel To fix the cams to the rack tighten the screws issued N B In addition to the electric stop cams mentioned above you must also install strong mechanical stops preventing the gate from sliding out of the top guides MAINTENANCE To be carried out exclusively by skilled persons after the power supply to the motor has been interrupted Periodically when the gate is standstill clean and keep the guide free from stones and dirt Meas
129. ta un m ximo de 2 5m EN 12445 punto 7 3 2 1 es columnas altas de 2 2mt 6 par de fotoc lulas 3 internas y 3 externas mejor Si est n provistas de sincronismo 6 FIT SYNCRO con 2 TX SYNCRO go PS Es obligatorio la puesta a tierra del sistema Los datos descritos en el presente manual son s lamente indicativos RIB se reserva de modificarlos en cualquier momento Realizar el sistema respetando las normas y las leyes vigentes LAYOUT IMPIANTO OR Re AVY RR Gd MUN AN i RCE Ge A o NN M ANN 9 4 MNA DIET IL IE PARO IT 1 Operatore K500 7 Limitatori di corsa 2 Fotocellule esterne 8 Costa meccanica 3 Cremagliera Modulo 4 9 Costa pneumatica o Fotocosta 4 Selettore a chiave 10 Fotocellule interne 5 Antenna radio 11 Colonnine per fotocellule 6 Lampeggiatore 12 Fermi meccanici 1 CARATTERISTICHE TECNICHE CARATTERISTICHE K500 TECNICHE SCH irreversibili per cancelli scorrevoli aventi un peso massimo di 500 Ena kg 500 L irreversibilit di questo operatore fa si che il cancello non richieda alcun tipo di Forza max di spinta N 400 serratura elettrica per un efficace chiusura x D N 9 5 motore protetto da una sonda termica che in caso di utilizzo prolungato interrompe pi dic m momentaneamente il movimento Cremagliera modulo 4 Alimentazione e frequenza 230V 50Hz 230V 60Hz Potenza motore W 229 228 Assorbimento A 1 21 1 05 EE Condensatore uF 10 i i
130. temps configur Le portail ne s ouvre pas et ne se referme pas en actionnant les diff rents boutons K et RADIO En actionnant le bouton K le portail n effectue aucun mouvement La phase de ralentissement ne s ex cute pas V rifier l int grit des fusibles F1 et F2 En cas de fusible en panne en utiliser uniquement de valeur ad quate F2 5A Fi 100mA V rifier le r glage des trimmers TORQUE et LOW SPEED S assurer d avoir configur le DIP 3 sur ON Bouton K BUTTON toujours ins r en mode de fonctionnement automatique DIP 6 OFF Remplacer le bouton ou interrupteur du s lecteur Autotest bande de contact chou gt v rifier les raccordements entre le tableau lectronique et l alimentateur des bandes de contact Attention si on n utilise pas un alimentateur pour bandes de contact le DIP 10 doit tre sur la position OFF Contact bande de contact de s curit en panne Contact photocellules en panne avec DIP 4 OFF Replacer ou remplacer le contact correspondant Impulsion K toujours ins r e Contr ler et remplacer les ventuels boutons ou microrupteurs du s lecteur S assurer que le DIP 8 soit sur la position OFF ralentissement activ Ex cuter l tude des temps travers la proc dure depuis DIP 2 V rifier le r glage trimmer LOW SPEED 2p OPTIONS Pour les branchements et les donn es techniques des accessoires se conformer aux livrets d instruction correspondants PLAQUE C
131. tielle et la refermeture Durant l ouverture la pause ou la fermeture pi tonne il est possible de commander l ouverture partir de n importe quelle commande raccord e la fiche Par l interm diaire du DIP 6 il est possible de choisir la modalit de fonctionnement du bouton de commande pi tonne Si DIP6 sur ON gt Ex cute une commande cyclique des commandes ouvre stop ferme Stop etc Si DIP6 sur OFF gt Ex cute l ouverture quand le portail est ferm Si il est actionn durant e mouvement d ouverture il n a pas d effet Si il est actionn quand e portail pi ton est ouvert il le ferme et durant la fermeture si il est actionn e il le fait se rouvrir RADIO EMETTEUR soit pour ouverture totale que pour pi tons Si DIP6 sur ON gt effectue une commande cyclique des commandes ouvre stop erme stop ouvre etc Si DIP6 sur OFF gt effectue l ouverture lorsque le portail est ferm Si ce poussoir est actionn au cours du mouvement d ouverture du portail son effet est nul S il est actionn lorsque le portail est ouvert il le referme S il est actionn au cours du mouvement de fermeture du portail il le rouvre FERMETURE AUTOMATIQUE EN OUVERTURE TOTALE Le temps de pause avant la fermeture automatique en ouverture totale du portail est enregistr enregistr s lors de la programmation des temps Le temps de pause maximal est de 5 minutes 21 Le temps de pause peut tre activ ou d
132. tr nico de la fuerza del motor TORQUE TORQUE REGULADOR ELECTR NICO DE LA FUERZA La regulaci n de la fuerza se lleva a cabo girando el regulador Trimmer TORQUE que sirve para variar la tensi n de salida en los extremos del motor girando en sentido horario se proporciona m s fuerza al motor Dicha fuerza se incluye autom ticamente 3 segundos despu s del inicio de cada maniobra para garantizar la aceleraci n m xima de salida al motor NOTAR SI ESTE TRIMMER SE REGULA DESPU S DE HABER PROGRAMADO ES POSIBLE QUE LA MEDIDA DE SEGUNAD VELOCIDAD TENGA VARIACIONES UN POCO MAS 0 MENOS EN RELACI N A LA ANTERIOR ASI QUE SE DEBE DE HACER UNA NUEVA PROGRAMACI N DE LOS TIEMPOS LOW SPEED REGULADOR DE LA VELOCIDAD DE DECELERACI N Si el dip 8 est en OFF la regulaci n de deceleraci n se la obtiene girando el Trimmer LOW SPEED que sirve para variar la velocidad del motor en la fase de acercamiento del final de apertura o de cierre girando en sentido horario se da m s velocidad al motor La deceleraci n viene determinada autom ticamente por la central durante la fase de programaci n de los tiempos y se activa a unos 50 60 cm antes de alcanzar el final de carrera en apertura o en cierre FRENO ELECTR NICO Sila segunda velocidad no se utiliza Dip 8 ON aconsejamos la conexi n del freno electr nico Dip 7 ON que dar inferior inercia de la cancela cuando se acercar al fin de carrera PARTENZA GRADUALE Con DIP 9 ON
133. tzes momentan die Bewegung unterbricht Module cr maill re 4 Stromspannung und frequenz 230V 50Hz 230V 60Hz Motorleistung W 229 228 Stromaufnahme A 1 21 1 05 Kondensator 10 Normative Zyklen n 12 30s 2s 10 30s 2s Max t gliche Zyklen n 300 1 Service 60 y cdd Garantierte kontinuierliche Zyklen n 25 5m D Schmiere COMLUBE LHITGREASE EP GR 2 245 Motorgewicht kg 8 Ger usch db lt 70 Betriebstemperatur C 10 55 Schutzart IP 54 Abmessungen in mm inch 88 D INSTALLATION K500 VOR DER MONTAGE AUSZUF HRENDE BERPR FUNGEN DAS TOR MUSS REIBUNGSFREI LAUFEN ANMERKUNG Es ist erforderlich die Charakteristiken des Tors an die geltenden Normen und Gesetze anzupassen Das Tor kann nur automatisch Angeschlossen werden wenn es in einem einwandfreien Zustand ist und der EN12604 entspricht Das Tor welches keine Gehfluegelfunktion hat in diesem Fall ist es erforderlich das Tor mit der norm EN12453 in Einklang zu bringen z B das in Bewegung setzen des Motors per Handsender wenn der Gehfluegel geoeffnet ist Das zu vehindern koennen sie einen Endschalter anschliessen der beim oeffnen des Gehfluegel andere automatischen ee funktionen ausser Kraft setzt Ausser der elektrischen und mechanischen Endschalter die mit der Steuerung verbunden werden ist es ratsam einen festen Endanschlagpunkt am Boden zu befestigen Der im K500 gegeben Fall einer Fehlfunktion der elektronik de
134. u contr le N B Pendant ce contr le les cordons et les photocellules sont inactives D PROGRAMMATION TEMPS OUVERTURE TOTALE 8 ATTENTION Si les entr es PHOT et EDGE ne sont pas raccord es faire des ponts entre COM PHOT et COM EDGE avant de proc der la programmation La programmation peut tre effectu e quelle que soit la position du portail 1 Positionner le micro interrupteur DIP 2 sur ON gt Le voyant lumineux DL1 commencera clignoter tr s rapidement 2 Appuyer sur le poussoir PROG gt le portail se ferme 2 secondes apr s sa fermeture le portail se rouvre tout seul D s qu il est enti rement ouvert il s arr te Attendre le temps que l on veut tablir pour que le portail reste ouvert pouvant tre exclu avec DIP3 OFF 3 Appuyer sur le poussoir PROG pour commander la fermeture du portail le led DL1 arr te de clignoter le comptage du temps d attente avant la fermeture est automatiquement m moris max 5 minutes 4 Une fois que e fin de course de fermeture a t atteint le portail s arr te 5 APR S AVOIR COMPL T LA PROGRAMMATION REMETTRE LE DIP 2 SUR OFF NOTA Le ralentissement est d termin automatiquement par la centrale en phase de programmation des temps et est activ environ 50 60 cm avant l atteinte du fin de course d ouverture ou de fermeture Cette mesure peut varier l g rement selon la temp rature D PROGRAMMATION TEMPS OUVERTURE
135. uni per i cancel attenersi alle norme e alle leggi vigenti 2 L installatore dovr rilasciare al alla EN 12635 uten i le porte e i portoni motorizzati e finale un libretto di istruzioni in accordo 3 L installatore prima di procedere con l installazione deve prevedere l analisi dei rischi della chiusura automatizza pericolosi identificati seguendo modifiche a questa apportate da e norme EN 4 Il cablaggio dei vari componenti elettrici fotocellule lampeggianti ecc deve essere effettuato secondo la EN 60204 1 e le pun 5 L eventuale montaggio di una p Isanti 0 5 2 2 era per a finale e la messa in sicurezza dei punti 2453 EN 12445 esterni all operatore ad esempio della EN 12453 il comando manuale del movimento deve essere fatto posizionando la pulsantiera in modo che chi la aziona non si trovi in posizione pericolosa inoltre si dovr fare azionamento accidentale dei pulsanti in modo che sia ridotto il rischio di 6 Tenete i comandi dell automatismo pulsantiera telecomando etc fuori dalla portata dei bambini comandi devono essere posti ad un altezza minima di 1 5mt dal suolo e fuori dal raggio d azione delle parti mobili 7 Prima di eseguire qualsiasi operazione di installazione regolazione manutenzione collegato a monte dello stesso dell impianto togliere la tensione agendo sull apposito interruttore magnetotermico LA DITTA RIB NON
136. ura completa de la cancela Despu s de cada abertura el cierre de la cancela es por lo tanto permitido s lo si la s costa s han superado el Test Funcional CUIDADO LA MONITORIZACI N DEL INGRESO COSTA PUEDE SER HABILITADO CON EL DIP 10 EN ON O DESHABILITADO CON EL DIP 10 EN OFF EN EFECTO EL TEST FUNCIONAL DE LAS COSTAS ES POSIBLE S LO EN EL CASO DE QUE SE TRATE DE DISPOSITIVOS DOTADOS DE UN ALIMENTADOR DE CONTROL PROPIO UNA COSTA MEC NICA NO PUEDE SER MONITORIZADA POR LO TANTO EL DIP 10 TIENE QUE SER POSICIONADO EN OFF ALARMAS DE AUTOTEST COSTA DIP 10 ON Al final de la abertura si la monitorizaci n de la costa tiene resultado negativo interviene una alarma visualizada por el intermitente que permanece encendido y por el buzzer si est conectado activo por 5 minutos en esta condici n el cierre de la cancela no es permitida s lo reparando la costa y presionando uno de los mandos habilitados es posible restablecer la normal funcionalidad BOTONERA DE STOP se puede conectar en serie a la grapa com n del fin de carrera Esta conexi n se aconseja cuando se utiliza la modalidad de funcionamiento autom tico DIP6 OFF Durante cualquier operaci n la botonera STOP manda la parada de la cancela FUNCIONAMIENTO A HOMBRE PRESENTE EN CASO DE AVER AS CON LOS ACCESORIOS DE SEGURIDAD Si el burlete de seguridad est estropeado o se queda apretado por mas de 5 segundos o si la fotocelula de seguridad se estropea o se queda em
137. urements in mm Measurements in mm ELECTRIC CONNECTIONS ME pcs AERIAL POWER SUPPLY SPARK 230Vac 50 Hz 230Vac 40W PEDESTRIAN BUZZER cs COMMON K STRIP I PHOTOCELLS gt FOR ACCESSORIES SUPPLY FOR AUTOTEST STRIP 24Vdc 0 4A 15 24Vdc 0 4A 15 K PEDESTRIAN KEY SELECTORS BLOCK AND PUSH BOTTON FLAT PHOTOCELLS FIT SLIM MECHANICAL SAFETY STRIP 28 POINT A ELECTRIC CONNECTIONS Et no DO NOT REMOVE ANY JUMPER OTHERWISE THE Mero OPERATOR WILL NOT WORK J2 AERIAL Radio Antenna LSC Close limit switch that cuts off the motor in closing LSO Open limit switch that cuts off the motor in opening COM Limit switch common contact PED BUTT Pedestrian opening contact NO J3 L N Main power supply 230 Vac 50 60 Hz 120V 60Hz upon request J4 EARTH Connection of the earth line 1 J5 RADIO Built in radio module model CRX or connector for radio receiver RIB 24Vdc supply J6 A TEST 24Vdc safety strip self test power supply A Accessories power supply 24Vdc A Accessories power supply 24Vdc COM Common contact common line for all the command and safety inputs K BUTT Single pulse contact NO PHOT Photocells contact NC EDGE Safety strip contact NC ah i Buzzer contact 24Vdc max 200 mA J Flashing light max 40 U MOTOR Motor common connection V W Motor phase and capacitor connections MOTO
138. ust be fully closed 2 Turn DIP2 to ON position the LED DL1 starts blinking quickly 3 Immediately turn also DIP1 to ON position the LED DL1 starts blinking slowly 4 Press the pedestrian pushbutton PED BUTT the gate opens 5 When the gate leaf is opened enough for the pedestrian crossing press the pedestrian pushbutton PED BUTT to stop the travel thus defining the opening stroke of the motor The gap of time between now stop of the motor and the next pressing of the PROG button see point 6 below will be stored as waiting time for Pedestrian Automatic Closing feature 6 Press the pedestrian pushbutton PED BUTT gate closes and the Pedestrian Automatic Closing time is stored see DIP3 function to enable or disable the Automatic Closing feature 7 Turn DIP1 to OFF position 8 Turn DIP2 to OFF position During Point E procedure the safety devices photocells and safety strip are active POINT F PROGRAMMING RADIO CODES FOR COMPLETE OPENING UP TO 30 CODES ONLY FOR CRX MODELS You can only programme the codes if the gate is closed 1 Position DIP 1 to ON and then DIP 2 to ON 2 The red programming DL1 LED will flash ON and OFF one second on each for 10 Seconds 3 Press the remote control button normally channel A within the 10 seconds proscribed If the remote control has been correctly programmed the DL2 LED green will flash once 4 The code programming time resets automatically so that you c
139. ute Alarm kann man die Funktion des Tores wiederherstellen indem man eine beliebige Schalttaste dr ckt BERWACHUNG DER SICHERHEITS RIPPEN A TEST A Mit dem Eingang A TEST sowie DIP 10 ON kann k nnen die Rippe n berwacht werden Die berwachung der Rippe besteht aus einem Funktionstest und wird bei jeder komplett erfolgten Tor ffnung ausgef hrt Nach jeder Tor ffnung kann die Schlie ung deshalb nur dann erfolgen wenn die Rippe n den Funktionstest erfolgreich berstanden haben ACHTUNG DIE BERWACHUNG RIPPEN EINGANG KANN MIT DIP10 AUF ON BEF HIGT ODER AUSGESCHLOSSEN WERDEN MIT DIP10 AUF OFF IST DER FUNKTIONSTEST F R DIE RIPPEN NUR M GLICH WENN ES SICH UM EINE VORRICHTUNG HANDELT DIE MIT EINEN EIGENEN NETZANSCHLUSS F R DIE KONTROLL BERWACHUNG VERSEHEN IST EINE MECHANISCHE RIPPE KANN NICHT BERWACHT WERDEN DESHALB MUSS DIP10 AUF OFF POSITIONIERT WERDEN ALARM VON AUTOTEST RIPPE COSTA DIP 10 ON Wenn das Ergebnis der berwachung der Rippe nach ffnung des Tores negativ ausf llt erfolgt Alarm durch visualisierbaren Warnblinker sowie Buzzer wenn angeschlossen der Alarm bleibt 5 Minuten lang aktiv Bei dieser Kondition ist die Torschlie ung nicht m glich erst dann wenn die Rippe wiederhergestellt ist und unter Bet tigung einer der Befehlstasten kann die normale Funktionalit t wiederhergestellt werden STOP SCHALTER Kann in Serienausf hrung an der normalen Endlauf Klemme angebracht werden Di
140. verse le mouvement en fermeture pour 2 seconds et puis il s arr te Si le barre palpeuse intervient en fermeture il renverse le mouvement en ouverture pour 2 seconds et puis il s arr te Si la barre palpeuse demeure occup e contact NO aucune manutention automatique n est permise Si elles ne sont pas utilis es ponter les bornes COM EDGE N B est recommand de v rifier la fonctionnalit des barres palpeuses au moins une fois tous les 6 mois ALARME PAR BARRE PALPEUSE Quand le barre palpeuse intervient en produisant une inversion le portail s arr te dans la condition d alerte signal e par le clignotant actif pour 1 minute et par le buzzer actif pendant 5 minutes Durant ou apr s la minute d alarme il est possible de r tablir le fonctionnement du portail en appuyant sur n importe quel bouton poussoir de commande MONITORAGE BARRE PALPEUSE A TEST A Par l interm diaire de l entr e A TEST et du DIP 10 ON il est possible de monitorer le les cordon s Le monitorage consiste en un Test de Fonction du cordon effectu la fin de chaque ouverture compl te du portail Apr s chaque ouverture la fermeture du portail est donc permise seulement si le les cordon s ont r ussi le Test de Fonction ATTENTION LE MONITORAGE DE L ENTREE CORDON PEUT ETRE HABILITE AVEC LE DIP 10 SUR ON OU BIEN DESHABILITE AVEC LE DIP 10 SUR OFF EN EFFET LE TEST DE FONCTION DES CORDONS EST POSSIBLE SEULEMENT SI IL S AGIT DE DISPOSITIFS
141. vo per 5 minuti a questa condizione la chiusura del cancello non viene consentita solo riparando la costa e premendo uno dei comandi abilitati e possibile ripristinare la normale funzionalit PULSANTE DI STOP collegabile in serie al morsetto comune dei finecorsa Questo collegamento si consiglia quando viene usata la modalit di funzionamento automatico DIP 6 OFF Durante qualunque operazione il pulsante di STOP esegue il fermo del cancello FUNZIONAMENTO AD UOMO PRESENTE IN CASO DI GUASTO DELLE SICUREZZE Se la costa guasta o impegnata per pi di 5 secondi o se la fotocellula guasta o impegnata per pi di 60 secondi i comandi K BUTTON e PEDONALE funzioneranno solo ad uomo presente La segnalazione dell attivazione di questo funzionamento data dal led di programmazione che lampeggia Con questo funzionamento viene consentita l apertura o la chiusura solo mantenendo premuti i pulsanti di comando Il comando radio e la chiusura automatica vengono esclusi in quanto il loro funzionamento non consentito dalle norme Al ripristino del contatto delle sicurezze dopo 1 secondo viene automaticamente riabilitato il funzionamento automatico o passo passo e quindi anche il radiocomando e la chiusura automatica riprendono a funzionare Nota 1 durante questo funzionamento in caso di guasto alle coste oppure fotocellule le fotocellule oppure coste funzionano ancora interrompendo la manovra in atto La manovra a uomo presente esc
142. while the gate is still it will open if a open command is request it will remain still if a close command is request The photocell input PHOT COM is a NORMALLY CLOSED contact In case there are more couple of photocells the contacts from all the photocell receivers must be connected in series In case the photocells are not installed this contact must be short circuited with a wire jump from PHOT to COM to permit the gate to operate SAFETY STRIP EDGE COM If it intervenes during opening it inverts the movement and closes for 2 seconds and then stops If it intervenes during closing it inverts the movement and opens for 2 seconds and then stops If the safety strip remains engaged NO contact no automatic movement is allowed In case the safety strip is not installed this contact must be short circuited with a wire jump from EDGE to COM to permit the gate to operate PAY ATTENTION it is highly recommended to check safety strips operation at least every 6 months SAFETY STRIP ALARM After the inversion given by the intervention of the safety edge the gate stops in alarm mode and this is signaled by the blinker on for 1 minute and by the buzzer on for 5 minutes During or after the minute of alarm the normal gate operations can be restored by pressing any push button TESTING THE SAFETY STRIP equipment The DIP10 ON enables to test the safety strip equi

Download Pdf Manuals

image

Related Search

Related Contents

La santé de l`homme - n° 358 - Septembre-Octobre 2006  biochimenea - La boutique de l`air  NCX-1900H  Elite Screens Kestrel Tension 84"  important safety instructions save these instructions installation  operating instructions and service manual football scoreboard    Siemens CX75 User's Manual  Manual del usuario  Evaluation de la mise en œuvre de la gratuité de la césarienne au  