Home
roscoe medical mini compressor nebulizer
Contents
1. Protection against harmful ingress of water IPXO Ordinary Degree of safety in the presence of flammable anesthetics or oxygen No AP APG Not suitable for use in the presence of flammable anesthetics or oxygen Mode of operation 20 min on amp 40 min off 5 YEAR WARRANTY Your Roscoe brand product is warranted to be free of defects in materials and workmanship for five years This device was built to exacting standards and carefully inspected prior to shipment Your Roscoe brand product is warranted to be free of defects in materials and workmanship If within such warranty period the product proves ATOPE the product will be repaired or replaced at the option of Roscoe edical This warranty does not cover device failure due to owner misuse or negligence or normal wear and tear The warranty does not extend to nondurable components which are subject to normal wear and need periodic replacement This warranty shall not apply to serial numbered products if the serial number has been removed or defaced or to defects or damages caused by unauthorized pe attachments or repairs negligence accident or any circumstance beyond oscoe Medical s control such as improper operation maintenance or storage If you have any questions about your Roscoe product or this warranty please contact an authorized Roscoe Dealer Manufactured for Roscoe Medical 21973 Commerce Parkway Strongsville Ohio 44149 Printed in Chi
2. It is recommended that the nebulizer and mouthpiece are thoroughly cleaned with hot water after each use and cleaned with a mild detergent after the last treatment of the day If your physician or respiratory therapist specifies a different cleaning procedure follow their instructions Rinsing after each treatment UU UNA Disconnect the air tube nebulizer and mouthpiece Gently twist the nebulizer to open it Rinse the nebulizer and mouthpiece with water Dry them with clean soft towel or let it air dry Reassemble the nebulizer when completely dry and put these parts in a dry sealed container Disinfections Please follow the following steps to disinfect your nebulizer unless otherwise specified by your physician It is suggested that the unit is disinfected after the last treatment of the day 1 2 Use one part white vinegar with three parts distilled water Make sure mixed solution is enough to submerge the nebulizer mouthpiece Complete Rinsing Steps 1 3 3 Wash the nebulizer mouthpiece in warm water and a mild detergent Then wash them in hot tap water 4 Submerge these parts in the vinegar and water solution for thirty minutes 5 Complete Rinsing Steps 3 5 Cleaning the compressor 1 Wipe daily with a damp cloth 2 Donotuse any powdered cleaners or soap pads which may damage the finish Filter change 1 Donotuse cotton or any other materials Do not wash or clean the filter Only use filters supp
3. tratamiento del d a Si su m dico o terapeuta de respiraci n especifica un procedimiento de limpieza diferente siga sus instrucciones Enjuague despu s de cada tratamiento UU a YN RA Desconecte el tubo de aire el nebulizador y la boquilla Gire con suavidad el nebulizador para abrirlo Enjuague con agua el nebulizador y la boquilla S quelos con una toalla limpia y suave o d jelos secar al aire Vuelva a armar el nebulizador cuando est completamente seco y guarde estas partes en un recept culo seco de cierre herm tico Desinfecciones Siga estos pasos para desinfectar su nebulizador a menos que su m dico especifique otra cosa Se sugiere desinfectar la unidad despu s del ltimo tratamiento del d a 12 1 Prepare una soluci n con una parte de vinagre blanco y tres partes de agua destilada Aseg rese de que la soluci n mezclada sea suficiente para sumergir el nebulizador y la boquilla 2 Siga los pasos 1 3 para realizar el enjuague 3 Lave el nebulizador y la boquilla en agua tibia con un detergente suave Luego l velos en agua caliente del grifo 4 Sumerja estas partes en la soluci n de agua y vinagre durante treinta minutos 5 Realice los pasos de enjuague 3 5 Limpieza del compresor 1 Limpielo a diaria con un pa o h medo 2 Nouse limpiadores en polvo ni estropajos porque pueden da ar el acabado Cambio de filtros 1 Nouse algod n ni ning n otro material No lave ni limpie el filtro U
4. A mepwas DE PRECAUCION PARA EL ALMACENAMIENTO 1 2 3 4 No guarde esta unidad bajo la luz directa del sol ni en un lugar donde haya altas temperaturas o humedad Mantenga la unidad fuera del alcance de los ni os Mantenga el cable alejado de superficies calientes No enrolle el cable alrededor del dispositivo Mantenga siempre la unidad desconectada cuando no est en uso menmas DE PRECAUCI N PARA LA LIMPIEZA 1 2 3 4 No sumerja la unidad en agua El agua puede da ar la unidad Desconecte la unidad del tomacorriente el ctrico antes de limpiarlo Limpie todas las partes necesarias despu s de cada uso siguiendo las instrucciones que aparecen en esta gu a FUNCIONAMIENTO DE SU COMPRESOR NEBULIZADOR Nota Antes de poner a funcionar su nebulizador por primera vez debe limpiarlo minuciosamente 1 Coloque su compresor nebulizador sobre una superficie plana y estable Aseg rese de que pueda alcanzar f cilmente los controles cuando est sentado Prepare los accesorios Importante Antes de poner a funcionar el nebulizador por primera vez debe limpiarlo minuciosamente Consulte la secci n P rocedimientos de limpieza en este manual wm 11 16 17 18 19 Gire con suavidad la parte superior del nebulizador en sentido contrario a las agujas del reloj para desarmar el nebulizador Llene la secci n inferior del nebulizador con el medicamento recetado por su ody Coloque el cono de
5. ROSCOEneoicau ROSCOE MEDICAL MINI COMPRESSOR NEBULIZER Guidebook MODEL NEB ROS READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE ROSCOE MEDICAL MINI COMPRESSOR NEBULIZER MODEL NEB ROS INSTRUCTIONS INDEX 1 Introduction 2 2 Product Identification 3 3 Important Safeguards 3 4 4 Operating Your Compressor Nebulizer 4 5 5 Cleaning 5 6 6 Replacement Parts amp Optional Accessories 6 7 Specifications 6 7 8 Warranty 7 1 INTRODUCTION Thank you for purchasing the Roscoe Medical Mini Compressor Nebulizer Itis a compact medical device designed to efficiently deliver physician prescribed medication to the bronchial lung passages and is intended for home health care use With proper care and use it will provide you with many years of reliable treatment This product is developed for the successful treatment of asthma allergies and other respiratory disorders It creates a stream of air that travels through a clear tube to the nebulizer When
6. a os causados por partes no autorizadas accesorios o reparaciones negligencia accidente o cualquier otra circunstancia fuera del control de Roscoe Medical como funcionamiento mantenimiento o almacenamiento inapropiados Si tiene alguna pregunta sobre el producto Roscoe o esta garant a p ngase en contacto con un distribuidor autorizado de Roscoe 15 Fabricado para Roscoe Medical 21973 Commerce Parkway Strongsville Ohio 44149 Impreso en China 16
7. air enters the nebulizer it will convert the prescribed medication into an aerosol mist for easy inhalation Your compressor nebulizer should be used under the supervision of a licensed physician and or a respiratory therapist We encourage you to thoroughly read this guidebook to learn about the features of this product Any use of this product other than its intended use should always be avoided 2 PRODUCT IDENTIFICATION Nebulizer o ES ee Filters 5pcs Air tube Mouthpiece Tube Connector Air Openings Power Switch 3 A IMPORTANT SAFEGUARDS Anote Read all instructions carefully before use A The TON basic p read and are needed when using an electrical product A propuct CAUTIONS 1 WARNING IF ANY OF THE MOTOR HOUSING PARTS SHOULD BECOME DETACHED OR BROKEN EXPOSING THE MOTOR OR OPERATION SHOULD BE DISCONTINUED IMMEDIATELY TO AVOID PERSONAL INJ URY OR FURTHER PRODUCT DAMAGE 2 To avoid electrical shock Keep the unit away from water Do not immerse the power cord or the unit in liquid Do not use while bathing Do not reach fora unit that has fallen into water immediately unplug the unit 3 Never operate the unit if it has any damaged parts including power cord if it has been dropped or submersed in water Promptly send it to a service center for examination and repair 4 The unit should not be used where flammable gas oxygen or aerosol spray products are being used 5 Disconnect th
8. centro de servicio para que un t cnico lo examine y repare 3 La unidad no debe usarse en lugares donde se use gas inflamable ox geno o productos en aerosol 10 4 5 Desconecte la unidad del tomacorriente el ctrico antes de limpiarlo llenarlo y despu s de cada uso No use otros accesorios a menos que los recomiende el fabricante A mepwas DE PRECAUCION PARA EL FUNCIONAMIENTO 1 2 3 Ul Conecte este producto en un tomacorriente con un voltaje apropiado para el modelo No utilice extensiones o adaptadores de corriente No deje desatendido este producto cuando est funcionando Nunca ponga a funcionar esta unidad si tiene un cable o enchufe da ado si ha sufrido una ca da ha entrado en contacto de alguna manera con agua o si no funciona correctamente Devu lvalo a un centro de servicio para reparaci n Si observa alguna anormalidad interrumpa el uso de inmediato hasta que la unidad haya sido examinada y reparada Desconecte siempre el producto inmediatamente despu s de usarlo Nunca permita que se tire sacuda tense retuerza o doble severamente el cable especialmente si est enchufado Se producir n da os en el punto de alta flexibilidad de la entrada del dispositivo que causar n rupturas y cortocircuitos Manipule el cable con cuidado para mantener su vida til Nunca bloquee los respiraderos de la unidad principal tampoco debe colocarla en un lugar donde los respiraderos queden obstruidos
9. e unit from the electrical outlet before cleaning filling and after each use 6 Donotuse other attachments unless recommended by manufacturer Aorerarino CAUTIONS Connect this product to an appropriate voltage outlet for your model Do not use with power strips or extension cords Do not run this product unattended N if ithas been dropped or in any way into water if it does not work properly Return it to a service center for repair 4 Ifany abnormality occurs discontinue use immediately until the unit has been examined and repaired Always unplug the product immediately after use oy Ul 7 Never block the air openings of the main unit or place it where the air openings may be obstructed A storace CAUTIONS 1 Do not store the unit under direct sunlight high temperature or humidity 2 Keep the unit out of reach of small children 3 Keep the cord away from heated surfaces Do not wrap the cord around 4 Always keep the unit unplugged while not in use AXcteanine CAUTIONS 1 Donotimmerse the unit in water It may damage the unit 2 Disconnect the unit from the electrical outlet before cleaning 3 Clean all necessary parts after each use as instructed in this guidebook 4 OPERATING YOUR COMPRESSOR NEBULIZER Note Prior to initial operation the nebulizer should be thoroughly cleaned 1 Place your Compressor Nebulizer on a flat and stable surface Be sure that you can easily reach the controls whe
10. ios opcionales Mascarilla para adulto mascarilla infantil tubo de extensi n adaptador en T Garant a 5 a os de garant a limitada Protecci n contra descargas el ctricas no Equipo Clase Il Partes aplicadas tipo BF boquilla mascarillas Protecci n contra ingreso perjudicial de agua IPXO ordinario Grado de seguridad en presencia de anest sicos inflamables u ox geno No AP APG No apto para uso en presencia de anest sicos inflamables u ox geno Modo de operaci n 20 minutos prendido y 40 minutos apagado 14 GARANT A DE 5A OS Su producto de la marca Roscoe est garantizado contra defectos en materiales y mano de obra por cinco a os Este aparato se fabric de acuerdo con normas exigentes y se inspeccion cuidadosamente antes de salir de la f brica Su producto de la marca Roscoe est garantizado contra defectos en materiales y mano de obra Si dentro de dicho per odo de garant a el producto resultara defectuoso se reparar o cambiar a opci n de Roscoe Medical Esta garant a no protege contra fallas del aparato causadas por negligencia o mal uso por parte del propietario o por desgaste normal Esta garant a no se extiende a los componentes no duraderos que est n sujetos al desgaste normal y necesitan cambiarse peri dicamente Esta garant a no aplica a productos que tienen n mero de serie si dicho n mero se quita o destruye o por defectos o d
11. lied by your distributor And do not operate without a filter 2 Change the filter every 30 days or when the filter turns gray 3 Changing procedure a Remove the filter cover b Replace the used filter with a new one c Replace the filter cover 6 REPLACEMENT PARTS OPTIONAL ACCESSORIES Replacement parts are available through your local retailer Optional accessories include adult child masks and baby pacifier inhalers 7 SPECIFICATIONS Power AC 120V 60Hz Power Consumption 1 5A Medication Capacity 5ml Particle Size 0 5 to 10 um MMAD 4 um Sound Level Less than 60 dB at 1 meter Average Nebulization Rate gt 0 18ml min Compressor Pressure Range 17 4 to 29 Psi 0 12 to 0 20 Mpa Operating Pressure Range 7 25 to 10 Psi 0 05 to 0 07 Mpa Liter Flow Range 4 5 7 0 Lpm Operating Temperature Range 10 C to 40 C 50 F to 104 F Operating Humidity Range 10 to 90 RH Storage Temperature Range 25 C to 70 C 13 F to 158 F Storage Humidity Range 10 to 95 RH Dimension L x W x H 210 x 145 x 91mm 8 27 x5 70 x 3 58 Weight 2 55Lbs 1 16kg Nebulizer Air Tube Mouth piece Standard Accessories Filters 5pcs Adult mask Child mask O pionalAceesrones Extension Tube T adapter Warranty 5 year limited warranty Protection against electric shock o Class Il Equipment Type BF applied parts Mouth piece masks
12. n you are seated 2 Getaccessories ready Important Prior to initial operation the nebulizer should be thoroughly cleaned referring to the Cleaning Procedures in the manual 3 Gently twist the top part of the nebulizer counter clockwise to disassemble the nebulizer 10 11 5 Fill the bottom section of the nebulizer cody with the medication prescribed by your physician Be sure that the cone is put Place cone inside inside the bottom section and fill medication Gently twist the top part clockwise to re assemble the nebulizer Be sure the two sections fit well Attach one end of air tube to the base of the nebulizer Attach the other end of air tube to the air tube connector located on the back of the compressor Attach mouth piece to the top section of nebulizer Plug the power cord into an appropriate electrical outlet Make sure at this stage the power switch is at OFF status Press power switch to begin your prescribed treatment Important The compressor motor has a thermal protector which will shut off the unit before the unit is overheated When the thermal protector shuts the unit off please a Switch off the unit b Unplug the unit from the electrical outlet c Wait 40 minutes for the motor to cool down before another treatment Make sure the air openings are not obstructed When treatment is finished shut off the unit and unplug it from the electrical outlet CLEANING
13. na ROSCOEneoicau ROSCOE MEDICAL MINICOMPRESOR NEBULIZADOR Gula MODELO NEB ROS LEA DETENIDAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE USAR EL PRODUCTO ROSCOE MEDICAL MINICOMPRESOR NEBULIZADOR MODELO NEB ROS INSTRUCCIONES NDICE 1 Introducci n 9 2 Identificaci n del producto 10 3 Precauciones importantes 10 11 4 Funcionamiento del compresor nebulizador 11 12 5 Limpieza 12 13 6 Partes de repuesto y accesorios opcionales 13 7 Especificaciones 13 14 8 Garant a 15 1 INTRODUCCI N Gracias por comprar el Minicompresor Nebulizador Roscoe Medical Es un aparato m dico compacto que se dise para llevar con eficiencia el medicamento prescrito por el m dico a los conductos bronquiales y pulmonares y su uso es para cuidado en casa Con el cuidado y uso adecuados le proporcionar muchos a os de tratamiento confiable Este producto se desarroll para el tratamiento exitoso del asma alergias y otros trastornos respiratorios Crea una corriente de aire que viaja por una sonda transparente hasta el neb
14. ntro y m dico Asegurese de colocar el cono llene con medicamento dentro de la secci n inferior am Gire con suavidad la parte superior en el sentido de las agujas del reloj para volver a armar el nebulizador Aseg rese de que las dos secciones encajen bien Conecte un extremo del tubo de aire a la base del nebulizador Conecte el otro extremo del tubo de aire al conector del tubo de aire que se localiza en la parte posterior del compresor Inserte la boquilla en la secci n superior del nebulizador Conecte el tubo de corriente en una toma de electricidad apropiada En esta etapa aseg rese de que el interruptor de electricidad est en la posici n OFF Apagado Oprima el interruptor de electricidad para comenzar el tratamiento que le recet el m dico Importante El motor del compresor tiene un protector t rmico que apaga la unidad para evitar que la unidad se sobrecaliente Cuando el protector t rmino apague la unidad por favor a Apague la unidad con el interruptor b Desenchufe la unidad del tomacorriente c Espere 40 minutos a que el motor se enfr e antes de iniciar otro tratamiento Aseg rese de que nada obstruya los respiraderos Cuando termine su tratamiento apague la unidad y desench fela del tomacorriente 5 LIMPIEZA Se recomienda limpiar minuciosamente el nebulizador y la boquilla con agua caliente despu s de cada uso l velos con un detergente suave despu s del ltimo
15. se s lo filtros proporcionados por su distribuidor No ponga a funcionar el aparato sin filtro Cambie el filtro cada 30 d as o cuando el filtro se vuelva gris 3 Procedimiento para cambiar el filtro a Quite la tapa del filtro b Cambie el filtro usado por uno nuevo c Vuelva a poner la tapa del filtro N 6 PARTES DE REPUESTO Y ACCESORIOS OPCIONALES Las partes de repuesto se venden en tiendas minoristas de su localidad Los accesorios opcionales incluyen mascarillas para adulto e infantiles e inhaladores para beb s 7 ESPECIFICACIONES Corriente CA 120V 60Hz Consumo de energ a 1 5A Capacidad para medicamento 5ml Tama o de las part culas 0 5a10um MMAD 4 um Nivel de sonido Menos de 60 dB a 1 metro Tasa promedio de nebulizaci n 0 18ml min Ranga PiesionesQe 17 4 a 29 Psi 0 12 a 0 20 Mpa compresor Rango de presiones de 7 25 a 10 Psi 0 05 a 0 07 Mpa operaci n Rango de caudal en litros 4 5 7 0 Lpm Rango de temperaturas de 10 C a 40 C 50 F a 104 F 13 operaci n Rango de humedad de operaci n 10 a 90 RH Rango de temperaturas de almacenamiento 25 C a 70 C 13 F a 158 F Rango de humedad de almacenamiento 10 a 95 RH Dimensiona LxA xH 210 x 145 x 91mm 8 27 x5 70 x 3 58 Peso 2 55Lbs 1 16kg Accesorios est ndares Nebulizador tubo de aire boquilla filtros 5 piezas Accesor
16. ulizador Cuando el aire entra en el nebulizador convierte el medicamento recetado en una neblina en aerosol para facilitar su inhalaci n Su compresor nebulizador debe usarse bajo la supervisi n de un m dico o un especialista en terapia respiratoria autorizado Lo exhortamos a leer detenidamente y por completo esta gu a para conocer las caracter sticas de este producto Debe evitar todo uso de este producto que no sea el uso previsto 2 IDENTIFICACI N DEL PRODUCTO Nebulizador _________ gt Tubo de aire be Sy GQ Filtros 5 piezas Boquilla ___ Conector del tubo Respiradero Interruptor de electricidad 3 A PRECAUCIONES IMPORTANTES ZA NOTA Lea detenidamente todas las instrucciones antes de usar el producto Las siguientes medidas de precauci n b sicas son necesarias cuando se usa un MA el ctrico ADVERTENCIA El no leer y observar todas las precauciones puede ocasionar lesiones personales o da os en el equipo A mebipas DE PRECAUCI N PARA EL PRODUCTO 1 ADVERTENCIA SI ALGUNA DE LAS PIEZAS DE LA CARCASA DEL MOTOR DEBE SEPARARSE O DESCONTINUARSE O EL MOTOR U OTROS COMPONENTES EL CTRICOS QUEDAN EXPUESTOS DEBE SUSPENDER EL FUNCIONAMIENTO DE INMEDIATO PARA EVITAR LESIONES PERSONALES U OTROS DANOS EN EL PRODUCTO 2 Nunca opere la unidad si tiene da os en alguna de sus partes incluido el cable de corriente si ha sufrido una ca da o se ha sumergido en agua Env elo de inmediato al
Download Pdf Manuals
Related Search
Related Contents
manual instruções NIB—13° Il Black & Decker FP6010 Use & Care Manual e Owner`s Manual with Assembly Instructions f Guide - Fisher Primário Castanho S/R 5.3 Receiving e-mail, MMS and SMS messages - Mobile V7 17.0" Privacy Filter for desktop and notebook monitors 5:4 16 - Lirmm Copyright © All rights reserved.
Failed to retrieve file