Home
Voltage Stabilizer Owner`s Manual - OPTI-UPS
Contents
1. Voltage Stabilizer Owner s Manual Thank you for purchasing the Voltage Stabilizer made by OPTI UPS This owner s manual includes important safety guidelines for operation and the installation procedures of this Voltage Stabilizer If you have any problems with this product please refer to this manual before contacting customer service 1 IMPORTANT SAFETY INSTRUCTIONS e WARNING SAVE THESE INSTRUCTIONS This manual contains important instructions that must be followed during installation and maintenance of this Voltage Stabilizer WARNING Controlled Environment Intend for installation in a controlled environment 2 PRESENTATION Voltage Stabilizer unit can provide you with microprocessor controlled Automatic Voltage Regulation function It will supply your equipment with pure and stable power 2 1 OFF mode no indicator The situation caused by 1 Power switch is turn off 2 Manual switch is tripped 3 No utility power 2 2 NORMAL mode indicator green The indicator will illuminate when the utility input is normal 2 3 BUCK mode indicator yellow The indicator will illuminate when the voltage of utility input is high Utility input is over the rated limit the buck mode of automatic voltage regulator is enabled 2 4 BOOST mode indicator yellow The indicator will illuminate when the voltage of utility input is low Utility input is under the rated limit the buck mode of automatic voltage regulat
2. bles No abra la Boost caja superior para prevenir cortocircuitos Atienda a personal de Panel Frontal LED servicio capacitado PRECAUCI N Evite que el Estabilizador de voltaje sea expuesto al sol calentadores u otras fuentes de calor PRECAUCI N Para prevenir el sobrecalentamiento asegtirese de que las aperturas de ventilaci n no est n cubiertas PRECAUCI N Mantega la unidad fuera del polvo y la humedad 3 INSTALACI N 5 LOCALIZACI N DE AVER AS 3 1 Inspecciones Inspeccione el Estabilizador al recibirlo El empaquetado es El bot n de i B reciclable cons rvelo o reciclelo apropiadamente ON OFF esta fuera Presione el bot n de No se enciende el 2 encendido 3 2 Localizaci n Estabilizador de posici n Instale el Estabilizador de Voltaje en reas controladas con buena ventilaci n y libre de polvo No operar el Estabilizador al aire libre Interruptor T rmico Reencienda el fuera de servicio Interruptor T rmico cas Bu 6 ESPECIFICACIONES Aseg rese de que las polaridades y tipos de receptores coincidan con la unidad Por otra parte aseg rese de que las cargas de los aparatos conectados se mantengan menor a la capacidad de la unidad MODELO 551200 552000 x Capacidad 600W 1000W 4 OPERACION ENTRADA 110V 115V 120V 15 4 1 Bot n ON 50 o 60Hz Bajo alimentaci n presione ON para encender el Estabilizador de 110V 115V 120V Tipico 5 Voltaje Luego conecte los aparatos a conectar ej moni
3. favor estudie cuidadosamente y conserve este manual Muchas gracias por elegir nuestro Estabilizador de Voltaje La 1 2 Modo Normal Indicador Color Verde unidad le proveer una protecci n perfecta de los aparatos Representa un funcionamiento normal conectados Este manual es una gu a de instalaci n y empleo que incluye importantes instrucciones de seguridad para la operaci n y la instalaci n correcta del Estabilizador de Voltaje Si se encuentra con alg n problema al utilizarlo favor refi rase al manual antes de llamar al servicio de atenci n al cliente 1 3 Modo Buck down Indicador Color Amarillo El indicador se enciende cuando se produce una subida de tensi n Cuando la tensi n sobrepasa el l mite el modo de regulaci n de voltaje buck down se activa autom ticamente 1 4 Modo Boost Indicador Color Amarillo El indicador se enciende cuando se produce una bajada de tensi n 1 IMPORTANTES INSTRUCCIONES DE SEGURIDAD Cuando la tensi n es inferior al imite el modo de regulaci n de voltaje buck se activa autom ticamente O AVISO Conserve estas instrucciones Este manual contiene importantes instrucciones que deber n ser seguidas durante la instalaci n y mantenimiento del Estabilizador de Voltaje Buck AVISO Ambiente Controlado Asegtrese de instalar el dispositivo gt Normal Mode bajo un ambiente controlado e PRECAUCI N La unidad no contiene piezas reusa
4. load protection In the event of an over load condition the input manual switch will pop out This is a safety protection 4 4 Output short circuit protection When the output loads are shorted the input manual switch will pop out This will protect the AVR Warning Once the manual switch is opened please turn on the unit again after 60 seconds to let the manual switch cool down This can extend the life of the manual switch Possible Cause ON OFF switch is in Or the OFF position ah br m position Manual return switch Turn on the manual is opened return switch 6 SPECIFICATIONS MODEL SS1200 SS2000 600W 1000W INPUT Voltage Stabilizer cannot be turned on PROTECTION Surge Energy 525 Rating OUTPUT Data Line Net weight 1 6 3 52 1 8 3 96 kg Ib PHYSICAL Dimension lack W L H 123 136 102 mm Ambient 3 500 meters max elevation 0 95 Operation humidity non condensing 0 40 C ENVIRONMENT Audible Noise lt 40dBA 1 meter from surface Storage 15 000 meters max Specifications are subject to change without notice 2 PRESENTACION ESTABILIZADOR DE VOLTAJ E Esta unidad provee la funci n de estabilizar el voltaje mediante un microprocesador de control con el objetivo de ofrecerle una energ a pura y estable MANUAL DE INSTRUCCIONES 1 1 Modo OFF Indicadores Apagados Representa 1 Unidad apagada 2 Interruptor T rmico averiado 3 Sin corriente el ctrica Por
5. or is enabled Buck o CAUTION Risk of electric shock do not remove cover No user gt Normal Mode serviceable parts inside Refer servicing to qualified service SB Boost personnel e CAUTION Avoid exposing Voltage Stabilizer to direct sunlight Front Panel LED stoves or any other heat source e CAUTION Prevent overheating by making sure that the ventilation openings of the unit are not covered e CAUTION Keep unit away from any moisture or dusty areas 3 INSTALLATION 5 TROUBLESHOOTING 3 1 Inspection Inspect the Voltage Stabilizer upon receipt The packaging is recyclable save it for reuse or dispose of it properly 3 2 Placement Install Voltage Stabilizer in controlled area with adequate air flowing and free of excessive dust Do not operate the Voltage Stabilizer in an outdoor environment 3 3 Utility Power Be sure the polarities and types of the receptacles match the unit The capacity of this unit must be higher than the protected load If the capacity of Voltage Stabilizer unit is not sufficient the manual switch will pop out 4 OPERATION 4 1 Switch on When the Voltage Stabilizer is connected to utility input press the ON button to turn on the Voltage Stabilizer Then connect the electrical cords of the equipments that will be used such as computer or monitor to the rear panel of the Voltage Stabilizer unit 4 2 Switch off Press the OFF button to turn off the Voltage Stabilizer 4 3 Over
6. tor de SALIDA 50 o 60Hz ordenador a los tomacorrientes en el panel trasero del Estabilizador 72 EEE y Protecci n Interruptor T rmico de Voltaje Protecci n Interruptor T rmico 4 2 Bot n OFF PROTECCI N Onda de Energia 525 Para apagar el Estabilizador de Voltaje presione el bot n OFF a 4 3 Protecci n de Sobrecarga Li a de datos Cuando la unidad este funcionando bajo sobrecarga el Interruptor Peso Neto _ kg lb 1 6 3 52 1 8 3 96 T rmico queda fuera de servicio para protejer la unidad CARACTER ST Dimensiones PR EEE ICAS F SICAS Ancho Fondo Al 123 136 102 mm rotecci n de cortocircuito to Cuando la unidad este funcionando bajo cortocircuito en las cargas Ambientede 3 500 m m xima alture 0 95 el Interruptor T rmico queda fuera de servicio para proteger la Humedad 0 40 C unidad AMBIENTE Ruidos audibles lt 40dBA 1 metro de la superficie Calentamiento Una vez fuera de servicio espere 60 segundos Condiciones de 15 000 metros m x BR Almacenamiento antes de encender la unidad para que el Interruptor T rmico vuelva a Subjecto de especificaciones estar combiada por las noticias la normalidad Este proceso ayuda a prolongar la vida del Interruptor