Manual de Instruções MC-153

image

Contents

1. 2 12 1 neret entrate rid leo A General Specifications B Electrical Specifications 8 MAINTENANCE A Cleaning 22 B Battery Replacement 22 C Fuse Replacement cocer foda analisa sab 22 9 WARRANTY S 23 A Warranty Certificate Registration Procedures 24 13 1 GENERAL OVERVIEW This capacitance meter is able to measure capacitance of capacitor It will not measure the Q factor of reactive components Incorrect readings can be displayed when trying to measure the capacitance of resistive loads When measuring capacitance make sure that the component or circuit under test is de energized before make measurements Avoid to short circuit the test leads Instruments used in aggressive environments must be cleaned and send to calibration periodically Before replace the battery or the fuse make sure that the meter is turned off and disconnected from any circuit or component To make measurements the black test lead must be connected at negative terminal and the red test lead to positive terminal Before measurements of electrolytic capacitors make sure that is fully discharged To guarantee the accuracy of measurement do not touch the terminals during the measurement Donotallow that the instrument to be exposed to high temperatures and the direct incidence of sunlight to avoid the reducti
2. Display LCD Lectura m xima de 1999 Medidas C Capacitancia e Rangos 9 posiciones rango de valor 0 1pF hasta 20000pF Ajuste de Cero Manual 20pF Tiempo de Muestreo 0 5 segundos Ambiente de Operaci n 0 C a 40 C humedad relativa lt 80 MAX RH Indicaci n de Sobre rango Exhibe el d gito mas significativo 1 Alimentaci n Una bater a de 9V NEDA1604 IEC6F22 e Vida de la Bater a Aprox 200 horas alcalina Consumo T pico de 3 a 4mA rangos 200pF a 200mF Dimensiones 170 Al x 78 An x 42 P mm Peso 240g 32 B Especificaciones El ctricas La precisi n es dada como de la lec 23 5 lt 80 RH ura n mero de d gitos en 5 22 e Teste de max de Rango Precisi n Resoluci n Frecuencia indicaci n 200pF 0 5 7 0 1pF 800Hz 199 9pF 2nF 1pF 800Hz 1 999nF 20nF 10pF 800Hz 19 99nF 200nF S 100uF 800Hz 199 9nF 2uF 1000uF 800Hz 1 999uF 20yF 0 01uF 80hz 19 99uF 200uF 0 1uF 8Hz 199 9uF 2000 2 0 5 8Hz 1999uF 20000uF 3 0 10 10yF 8Hz 1999 x 10 uF pF Pico Farad 10 F nF Nano Farad 10 F uF Micro Farad 10 F Error de Cero 20pF Voltaje de Teste Maximo 2 8V RMS Protecci n de Sobrecarga Fusible 0 1A 250V 33 8 MANTENIMIENTO A Limpieza Peri dicamente limpie la parte externa del instrumento con pa o blando humedecido en agua o d
3. Nota Fiscal N Data N S rie Nome do Revendedor 11 A Cadastro do Certificado de Garantia O cadastro pode ser feito atrav s de um dos meios a seguir Correio Envie uma c pia do certificado de garantia devidamente preen chido pelo correio para o endere o Minipa do Brasil Ltda At Servico de Atendimento ao Cliente Av Carlos Liviero 59 Vila Liviero CEP 04186 100 S o Paulo SP Fax Envie uma c pia do certificado de garantia devidamente preen chido atrav s do fax 0xx11 5078 1885 e mail Envie os dados de cadastro do certificado de garantia atrav s do endere o sac minipa com br Site Cadastre o certificado de garantia atrav s do endere o http www minipa com br sac IMPORTANTE Os termos da garantia s ser o v lidos para produtos cujos certificados forem devidamente cadastrados Caso contr rio ser exigido uma c pia da nota fiscal de compra do produto Manual sujeito a altera es sem aviso pr vio Revis o 02 Data Emiss o 12 06 2012 12 SUMMARY 14 2 FEATURES coin 14 3 TERMS IN THIS MANUAL 4 ACCESSORIES 5 FRONT PANEL DESCRIPTION 6 OPERATION 17 A Measurement Consideration ener 17 B Capacitance 17 Z SPECIFICATIONS
4. inspecionado Se apresentar problemas durante o uso normal ser reparado de acordo com os termos da garantia GARANTIA S RIE N MODELO MC 153 1 Este certificado v lido por 12 doze meses a partir da data da aquisic o Ser reparado gratuitamente nos seguintes casos A Defeitos de fabricac o ou danos que se verificar por uso correto do aparelho no prazo acima estipulado B Os servicos de reparac o ser o efetuados somente no departa mento de assist ncia t cnica por n s autorizado C Aquisic o for feita em um posto de venda credenciado da Minipa A garantia perde a validade nos seguintes casos A Mau uso alterado negligenciado ou danificado por acidente ou condi es anormais de opera o ou manuseio B O aparelho foi violado por t cnico n o autorizado Esta garantia n o abrange fus veis pilhas baterias e acess rios tais como pontas de prova bolsa para transporte termopar etc Caso o instrumento contenha software a Minipa garante que o software funcionar realmente de acordo com suas especifica es funcionais por 90 dias A Minipa n o garante que o software n o contenha algum erro ou de que venha a funcionar sem interrup o 6 A Minipa n o assume despesas de frete e riscos de transporte 7 Agarantia s ser v lida mediante o cadastro deste certificado devidamente preenchido e sem rasuras 2 1 A a 1 Nome Endereco Cidade Estado Fone
5. calor por largos per odos 6 Antes de remover la tapa de la bater a o del compartimiento del fusible verificar si el instrumento est desconectado del circuito y que la llave est en la posesi n OFF 7 Para todas medidas debe se conectar la punta de prueba negra en el terminal y la punta de prueba roja en el terminal B Medici n de Capacitancia 1 Seleccione la llave de rango en el valor m ximo esperado de capacitancia 2 Verifique indicaci n 0 En los rangos de teste de 200pF 2pF 20nF verifique si la indicaci n es 0 Caso la indicaci n no sea 0 utilice el ajuste de cero 3 Observe la polaridad cuando conectar condensadores polarizados 4 Descargue completamente el condensador o en caso de una medida en un circuito desligue la alimentaci n y descargue todos los condensadores del circuito antes de la medida 5 Conecte las puntas de prueba negra y roja respectivamente a los terminales y y conecte las pinzas cocodrilos a los terminales del componente O utilice el adaptador MAK 2 para conectar el condensador a el capacimetro 29 6 Efect e la lectura del display El valor de lectura es directa en las unida des pF nF y uF indicada en la selectora de rango solamente el rango 2000pF x10 que la lectura debe ser multiplicada por 10 para encontrar el valor de la capacitancia Si el display exhibe solamente el d gito m s significativo 1 es una indicaci n de sobre rango portanto seleccion
6. cuidadosamente Si alguna falta ocurre bajo uso normal este producto ser reparado seg n condiciones y AN hinipo limitaciones de la garantia GARANT A N SERIE MODELO MC 153 El per odo de la garant a es 12 doce meses y comienza la fecha de la compra 2 Ser reparado gratuitamente en los siguientes casos A Los defectos de producci n o los da os ocurrieron bajo uso normal del instrumento dentro del per odo de la garant a B Los servicios de reparos ser n hechos solamente en departamento de asistencia t cnica por nosotros autorizado Si el producto fue comprado en un distribuidor autorizado de la Minipa 3 La garant a ser anulada en caso de que A Ha sido empleado mal alterado por negligencia o da ado por ac cidente o en condiciones anormales de operaci n o de manoseo B El instrumento demuestra violaciones por un t cnico no autorizado 4 Esta garant a no se aplica a los fusibles a las pilas a las bater as y a los accesorios como las puntas de prueba bolsa de transporte termopar etc 5 Para elinstrumento con software la Minipa asume la responsabilidad que el software funcionar de acuerdo con sus especificaciones funcionales por 90 d as La Minipa no garantizar que el software no contenga alg n error o funcionar sin interrupci n 6 La Minipa no asume ning n riesgo para da os en tr nsito ni los costes del transporte 7 La garant a ser v lida solamente despu s d
7. que podem causar danos ou mau funcionamento do instrumento ADVERT NCIA Para reduzir o risco de chama ou choque el trico n o exponha este produto a chuva ou umidade O instrumento proposto somente para uso interno S MBOLOS EL TRICOS INTERNACIONAL Cautela Risco de Choque El trico Cautela Risco de Perigo Terra Aterramento Dupla Isola o ou Isola o Refor ada 05244 AC Corrente Alternada 4 ACESS RIOS Verifique se os seguintes itens n o est o faltando ou danificados 1 Manual de Instru es 1 pe a 2 Ponta de Prova 1 par 3 Bateria 1 peca 4 Adaptador MAK 2 1 peca 5 DESCRI O DO PAINEL ZN ADVERT NCIA Desligue a alimenta o do circuito em teste e descarregue todos os capacitores antes da medida 1 Display LCD O display exibe o valor da medi o 2 Chave seletora de fun o Ela usada para mudar a faixa de medi o 3 Ajuste de zero Ajusta o zero quando em escalas de baixa capacit ncia 4 Terminal de entrada 5 Terminal de entrada Digital Capacitance Meter 6 OPERA O A Considera es para Medidas 1 Esse capac metro especifico para medir valores de capacit ncia de capacitores Ele n o especifico para determinar o fator Q dos com ponentes reativos Leitura enganosa pode ser obtida ao tentar medir a capacit ncia de um resistor 2 Quando medimos componentes dentro de um circuito desligue e dese nergize o circuito a
8. the rear side of instrument c Remove the four screws from the bottom case and open the instrument carefully d Replace the fuse with the same type and rating 5x20mm 100mA 250V e Place the bottom case the screws and the battery cover 22 9 WARRANTY This instrument was carefully calibrated and inspected If any failure oc curs under normal use this product will be repaired according to warranty AN Tnmimipo conditions and limitations 1 2 ow i A 1 a 1 6 Te WARRANTY SERIAL N MODEL MC 153 The warranty period is 12 twelve months and begins on the date of purchase It will be repaired free of charge in following cases A Manufacturing defects or damages occurred under normal use of instrument within the warranty period B The services to correct the failure will be done only in authorized service center or personal will be allowed to fix this product C If product is purchased through a Minipa s authorized dealer Warranty will be void in case A It has been misused altered neglected or damaged by accident or abnormal conditions of operation or handling B Theinstrument shows violations by a non authorized repair center This warranty does not apply to fuses dry cells batteries and ac cessories as test leads carrying case thermocouple etc For instrument with software Minipa assumes responsibility that the software will operate in accordance with its functional specifications
9. y la punta de prueba roja en el terminal Antes de la medida de condensadores electrol ticos certifique se de este est totalmente descargado Para garantir precisi n en la medida no permita que sus manos queden en contacto con los terminales durante la medida No permita que el instrumento sea expuesto a altas temperaturas y a la incidencia directa del rayo solar para evitar la disminuci n de la vida til del LCD En las medidas de capacitancias muy bajas es recomendado ajustar el cero de la lectura con las puntas de prueba abiertas antes de la medici n 2 CARACTER STICAS Lectura f cil y correcta Alta precisi n en las medidas Circuito interno de alta confiabilidad y durabilidad Protecci n de sobrecarga incorporada Display LCD de bajo consumo y f cil lectura mismo en ambientes con poca luminosidad Liviano y compacto para facilitar la operaci n Indicador de bater a agotada en el display 26 3 T RMINOS EN ESTE MANUAL ADVERTENCIA identifica condiciones o acciones que pueden resultar en serias heridas o mismo muerte para el usuario CAUTELA identifica condiciones y acciones que pueden causar da os o mal funcionamiento del instrumento ADVERTENCIA Para reducir el riesgo de llama o choque el ctrico no exponga este producto a lluvia o humedad El instrumento es propuesto solamente para uso interno S MBOLOS EL CTRICOS INTERNACIONAL Cautela Riesgo de Choque El ctrico Cautela Riesgo d
10. CAPAC METRO DIGITAL Digital Capacitance Meter MC 153 Imagem meramente ilustrativa Only illustrative image Imagen meramente ilustrativa AN Tninipa MANUAL DE INSTRU ES Instructions Manual IIA 1 SUM RIO 1 VIS O GERAL cct 02 2 CARACTER STICAS cosa asias 3 TERMOS NESTE MANUAL 4 ACESS RIOS 5 DESCRI O DO PAINEL 6 OPERA O o A Considera es para 05 B Medidas de Capacit ncia 05 7 6 2 222221 A Especifica es Gerais B Especifica es El tricas 8 MANUTEN O A Limpeza snsc camisa 10 B Troca de cc A a 10 Troca do FUS VEL os i 10 IQ GARANTIA 11 A Cadastro do Certificado de Garantia 12 1 VIS O GERAL Este capacimetro tem como fun o a medida da capacit ncia de capa citores N o tem como objetivo determinar o fator Q de componentes reativos Leituras incorretas podem ser obtidas na tentativa de medida da capacit ncia de um resistor Durante a medida de componentes em um circuito certifique se de que o mesmo esteja totalmente desenergizado antes de se efetuar a medida Evite curto circuitar as pontas de pro
11. ES tel 11 5078 1850 MINIPA DO BRASIL LTDA MINIPA DO BRASIL LTDA Av Carlos Liviero 59 Vila Liviero R Dona Francisca 8300 Bloco 4 04186 100 S o Paulo SP Brasil M dulo A 89219 600 Joinville SC Brasil MINIPA ELECTRONICS USA INC 10899 Kinghurst 4 220 Houston Texas 77099 USA
12. OS 5 DESCRIPCI N DEL PANEL 6 e e an 29 A Consideraciones para Medici n 29 B Medici n de Capacitancia sese 29 7 ESPECIFICACIONES nina etario 32 A Especificaciones Generales B Especificaciones El ctricas 8 MANTENIMIENTO AMINO Za AAA RR RR RR EREE dese RR 34 B Cambio do Balor a e ns 34 C Cambio de Fusible croceo e rre eria ounce aca ERE ENS 34 9 GARANTIA nitet etes is 35 A Procedimientos de Registro del Certificado de Garantia 36 25 1 VISI N GENERAL Este capac metro tiene como funci n la medida de la capacitancia de condensadores No tiene como objetivo determinar el factor Q de componentes reactivos Lecturas incorrectas pueden ser obtenidas en la tentativa de medida da capacitancia de un resistor Durante la medida de componentes en un circuito certifique se de que el mismo est totalmente desenergizado antes de se efectuar la medida Evite el corto circuito las puntas de prueba roja y negra Instrumentos usados en ambientes con poluci n deben ser limpios y enviados para calibraci n peri dicamente Antes de cambiar la bater a o el fusible certifique se de que el instrumen to est desligado y desconectado de cualquier circuito o componente Para efectuar las medidas la punta de prueba negra debe ser conectada en el terminal
13. cada por 10 para encontrar o valor da capaci t ncia Se o display mostrar apenas o d gito mais significativo 1 uma indica o de sobre faixa portanto selecione a pr xima faixa superior Se o display mostrar um ou mais zero 0 esquerda selecione a pr xima faixa inferior para obter uma resolu o melhor NOTAS a Se o valor da capacit ncia n o conhecido comece pela faixa de 200pF e aumente at que a indica o de sobre faixa n o seja mais mostrada b Um capacitor em curto apresentar a leitura de sobre faixa em todas as faixas de medida Um capacitor com fuga em baixa tens o apresentar leitura de sobre faixa ou um valor muito maior que o normal c A medida de capacit ncias muito baixas devem ser executadas usan do pontas de prova extremamente curtas para evitar a introdu o de capacit ncias parasitas d Quando utilizar pontas de prova opcionais lembre se de que as pontas de prova introduzem capacit ncias parasitas as medidas Como uma primeira aproxima o a capacit ncia das pontas de prova pode ser medida deixando as pontas de prova em aberto e efetuando a leitura do display Registre este valor e subtraia dos valores medidos a seguir e Capacitores especialmente os eletrol ticos normalmente apresentam uma toler ncia alta N o fique surpreso se o valor medido for muito maior que o valor marcado no capacitor a menos que seja um capacitor de precis o Entretanto os valores raramente
14. e el pr ximo rango superior Si el display exhibir un o mas ceros 0 a la izquierda seleccione el pr ximo rango inferior para obtener una reso luci n mejor 30 NOTAS a Si el valor da capacitancia no es conocido empiece por el rango de 200pF y aumente hasta que la indicaci n de sobre rango no sea m s exhibida b Un condensador en corto circuito presentar la lectura de sobre rango en todos los rangos de medida Un condensador con fuga en bajo voltaje presentar lectura de sobre rango o un valor mucho mayor que el normal c La medida de capacitancias muy bajas deben ser ejecutadas usando puntas de prueba extremamente cortas para evitar la introducci n de capaciancias par sitas d Cuando utilizar puntas de prueba opcionales acuerde se de que las puntas de prueba introducen capacitancias par sitas a las medidas Como una primera aproximaci n la capacitancia de las puntas de prueba pueden ser medidas dejando las puntas de prueba en abierto y efectuando la lectura del display Registre este valor y subtra a de los valores medidos a seguir e Condensadores especialmente los electrol ticos normalmente presen tan una tolerancia alta No quede sorpreso si el valor medido fuer muy mayor que el valor marcado en el condensador a menos que sea un condensador de precisi n Entretanto los valores raramente son muy menores que los valores nominales 31 7 ESPECIFICACIONES A Especificaciones Generales
15. e Peligro Tierra Aterramiento Doble Aislamiento o Aislamiento Reforzado 05244 AC Corriente Alternada 4 ACCESORIOS Verifique si las siguientes piezas no est n faltando o damnificados 1 Manual de Instrucciones 1 pieza 2 Punta de Prueba 1 par 3 Bater a 1 pieza 4 Adaptador MAK 2 1 pieza 27 5 DESCRIPCI N DEL PANEL ZN ADVERTENCIA Desligue la alimentaci n del circuito en teste y descargue todos los condensadores antes de la medida 1 Display LCD El display exhibe el valor de la medici n 2 Llave selectora de rango Ella es usada para cambiar el rango de medici n 3 Ajuste de cero Ajusta el cero cuando en rangos de baja capacitancia 4 Terminal de entrada 5 Terminal de entrada AN Wimipo 153 2009 20 20 Digital Capacitance Meter 28 6 OPERACI N A Consideraciones para Medici n 1 Este capacimetro es especifico para medir valores de capacitancia de condensadores El no es espec fico para determinar el factor Q de los componentes reactivos arriba Lectura enga osa puede obtener a tentar a medir la capacitancia de un resistor 2 Cuando medimos componentes dentro de un circuito desligue y dese nergize el circuito antes de conectar la punta de prueba 3 No aproxime mucho las puntas de pruebas negra y roja 4 Instrumentos usados en ambiente con polvo deben ser limpios peri di camente 5 El instrumento no permite quedar expuesto al
16. e capacitance in measurements As compensation the test leads capacitance can be measured leaving the test leads in open state and reading the capacitance at the display Record this reading and subtract it from the next measurements e Electrolytic capacitors present low accuracy Do not be surprised if the reading is higher than the nominal specification at the capacitor unless itis a high accuracy capacitor However readings lower than the nominal value of capacitor is unusual 19 7 SPECIFICATIONS A General Specifications LCD Display Maximum reading of 1999 Measurements C Capacitance e Ranges 9 positions range of measurement 0 1pF to 200004F Zero Adjustment Manual 20pF Sampling Time 0 5 seconds Operation Environment 0 C to 40 C relative humidity lt 80 max Overrange Indication Display shows the last significant digit 1 Power Supply One 9V battery NEDA1604 6 22 Battery Life Approx 200 hours alkaline battery Consumption 3 to 4mA typical ranges 200pF to 200uF Dimensions 170 H x 78 W x 42 D mm Weight 240g 20 B Electrical Specifications Accuracy a reading b digits at 23 C 5 C RH lt 80 Zero Error 20pF Test Voltage 2 8V RMS maximum Overload Protection 0 1A 250V fuse 21 Test Maximum Range Accuracy Resolution Frequency Indication 200pF 0 5 7 0 1
17. el registro de este certificado Nombre Direcci n Provincia Ciudad Fono Nota de la Venta N Data N Serie Nombre del Revendedor 35 A Procedimientos de Registro del Certificado de Garant a El registro se puede hacer por las siguientes maneras Correo Env e una copia del certificado de garant a llenada correcta mente a la siguiente direcci n Minipa do Brasil Ltda At Servico de Atendimento ao Cliente Av Carlos Liviero 59 Vila Liviero CEP 04186 100 S o Paulo SP Fax Env e una copia del certificado de garant a llenada correcta mente por el n mero de fax 0xx11 5078 1885 e mail Mande los datos del catastramiento del certificado de garant a por el e mail sac minipa com br Site Registre el certificado de garant a en http www minipa com br sac IMPORTANTE Las condiciones y limitaciones de la garant a ser n validas sola mente a los certificados registrados correctamente Caso contrario ser exigido una copia del recibo de la venta que muestra la fecha de la compra Manual sujeto a alteraciones sin aviso previo Revisi n 02 Data de Emisi n 12 06 2012 36 enci n mento i Yo MINIPA ONLINE F3 ONLINE z SCE er 8 Dudas Consulte 2 5 D vidas Consulte www minipa net WWW pa com br E Y Entre en Nuestro Foro Se Acesse F rum Sua resposta em 24 horas sac minipa net sac minipa com br tel 55 11 5078 1850 MES
18. etergente neutro tomando cuidado para no remover la serigraf a del panel frontal No utilice productos abrasivos o solventes ni mismo el alcohol B Cambio de Bater a Cuando el indicador de bater a agotada sea exhibido en el display Cambie inmediatamente la bater a para que el instrumento pueda ser mantenido en condiciones normales de operaci n Siga el siguiente procedimiento para cambiar la bater a a Verifique si el instrumento no esta conectado en ning n circuito Posesione la llave selectora en OFF y remueva las puntas de prueba de los terminales b Retire lo tres tornillos de la tapa localizado en la parte trasera del ins trumento c Retire la bater a descargada y cambie por una nueva de misma especi ficaci n Reponga la tapa y los tornillos C Cambio de Fusible Cuando ninguna medida fuer posible probablemente el fusible interno est quemado en este caso siga el siguiente procedimiento para cambiar el fusible a Verifique si el instrumento no esta conectado en ning n circuito Pose sione la llave selectora en OFF y remueva las puntas de prueba de los terminales b Retire lo tres tornillos de la tapa localizado en la parte trasera del ins trumento c Retire 4 tornillos de la parte trasera del instrumento y abra con cautela d Reponga el fusible del mismo tipo y categoria 5x20mm 100mA 250V e Reponga la tapa y los tornillos 34 9 GARANT A Este instrumento fue calibrado y examinado
19. for 90 days Minipa will not guarantee that the software will be error free or operate without interruption Minipa assumes no risk for damage in transit or transportation costs Warranty will be valid only afterthe registration ofthis certificate Name Address City State Phone Sales Voucher N Date Serial N Sales Agent Name 23 A Warranty Certificate Registration Procedures The registration can be made by following ways Mail Fax e mail Site Send a copy of warranty certificate correctly filled to the following address Minipa do Brasil Ltda At Servico de Atendimento ao Cliente Av Carlos Liviero 59 Vila Liviero CEP 04186 100 S o Paulo SP Send a copy of warranty certificate correctly filled by fax number 0xx11 5078 1885 Scanning this formand attach to your e mail Please send to sac minipa com br Register the warranty certificate by http www minipa com br sac IMPORTANT The warranty conditions and limitations will be valid only to the certificates correctly registered In case the purchaser did not register a sales receipt showing the date of purchase will be required Manual specifications subject to change without notice Revision 02 Date of Issue 12 06 2012 24 SUMARIO 1 4 26 2 CARACTERISTICAS cios cia 3 T RMINOS EN ESTE MANUAL 4 ACCESORI
20. ntes de conectar a ponta de prova 3 N o aproxime muito as pontas de prova preta e vermelha 4 Instrumentos usados em ambiente com poeira devem ser limpos perio dicamente 5 O instrumento n o pode ser exposto ao calor por longos per odos 6 Antes de remover a tampa da bateria ou do compartimento de fus vel verifique se o instrumento est desconectado do circuito e que a chave rotativa esteja na posi o desligada OFF 7 Para todas as medidas deve se conectar a ponta de prova preta no terminal e a ponta de prova vermelha no terminal B Medidas de Capacit ncia 1 Ajuste a chave rotativa no valor m ximo esperado de capacit ncia 2 Verifique indica o de 0 Nas faixas de teste de 200pF 2pF 20nF veri fique se a indica o 0 Caso a indica o n o seja 0 utilize o ajuste de zero 3 Observe a polaridade quando conectar capacitores polarizados 4 Descarregue completamente o capacitor ou no caso de uma medida em um circuito desligue a alimenta o e descarregue todos os capacitores do circuito antes da medida 5 Conecte as pontas de prova preta e vermelha respectivamente aos terminais e e conecte as garras jacar aos terminais do componente Ou utilize o adaptador MAK 2 para conectar o capacitor ao capacimetro 6 Efetue a leitura do display O valor de leitura direta nas unidades pF nF e uF indicada na chave rotativa Somente na faixa 2000UF x10 que a leitura deve ser multipli
21. on of LCD life Atlow capacitance measurements we recommend to adjust the zero reading with the test leads opened before the measurement 2 FEATURES Easy and correct readings High accuracy measurements Internal circuit with high durability and reliability Build in overload protection Low consumption LCD display and easy to read even in low light envi ronments Compact and light weight for easy operation Low battery indication in display 14 3 TERMS IN THIS MANUAL WARNING identifies conditions or practices that may result in serious wounds or even death CAUTION identifies conditions and practices that may cause da mage or instrument malfunction WARNING To reduce the risk of fire or electrical shock does not expose this instrument to rain or high humidity This instrument was designed to indoor use only INTERNATIONAL ELECTRICAL SYMBOLS Caution Risk of electrical shock Caution Risk of danger Earth Grounding Double Insulation or Reinforced Insulation 05244 AC Alternating Current 4 ACCESSORIES Check if the following items are not missing or damaged 1 Instructions Manual 1 piece 2 Test leads 1 pair 3 Battery 1 piece 4 MAK 2 Adaptor 1 piece 15 5 FRONT PANEL DESCRIPTION ZN WARNING Turn off the power of circuit under test and discharge all the capacitors before measurements 1 LCD Display The display shows the measurement 2 Rotary switch Used to
22. pF 800Hz 199 9pF 2nF 1pF 800Hz 1 999nF 20nF 10pF 800Hz 19 99nF 200nF 0 5 5 100 800Hz 199 9nF 2yF 1000 800Hz 1 999uF 20uF 0 01uF 80hz 19 99uF 200uF 0 14F 8Hz 199 9uF 2000uF 2 0 5 8Hz 1999uF 20000u4F 3 0 10 10uF 8Hz 1999 x 10 uF pF Pico Farad 102F nF Nano Farad 10 F uF Micro Farad 10 F 8 MAINTENANCE A Cleaning Periodically clean the meter with a soft cloth slightly wet with water or mild detergent and take care to not remove the overlay Do not use abrasives or solvents or even alcohol B Battery Replacement Replace the battery when the low battery indicator appears in LCD display Replace the battery immediately in order to keep the instrument in normal operation condition Follow the instructions below to replace the battery a Check if the instrument is not connected to any circuit Set the rotary switch to OFF and remove the test leads from input terminals b Remove the three screws at the rear side of instrument c Remove the old battery and replace it with a new battery with the same specifications d Place the battery cover and the screw C Fuse Replacement When any measurement was not possible probably the internal fuse burned out in this case please follow the steps below to replace the fuse a Check if the instrument is not connected to any circuit Set the rotary switch to OFF and remove the test leads from input terminals b Remove the three screws at
23. s o muito menores que os valores nominais 7 ESPECIFICA ES A Especifica es Gerais Display LCD Leitura m xima de 1999 Medidas C Capacit ncia e Faixa 9 posi es faixa de valor 0 1pF at 20000pF Ajuste de Zero Manual 20pF Tempo de Amostragem 0 5 segundos Ambiente de Opera o 0 C a 40 C umidade relativa lt 80 MAX RH Indica o de Sobre faixa Somente o d gito mais significativo 1 aceso Alimenta o Uma bateria de 9V NEDA1604 6F22 Vida da Bateria Aprox 200 horas alcalina Consumo T pico de 3 a 4mA faixas 200pF a 200yF Dimens es 170 A x 78 L x 42 P mm Peso 240g B Especifica es El tricas A precis o dada como da leitura n mero de d gitos a 23 C 5 C lt 80 RH Teste de max de Faixa Precis o Resolu o e EEE I Frequ ncia indica o 200pF 0 5 7 0 1pF 800Hz 199 9pF 2nF 1pF 800Hz 1 999nF 20nF 10pF 800Hz 19 99nF 200nF S 100 800Hz 199 9nF 2yF SEES 1000uF 800Hz 1 999uF 20uF 0 01yF 80hz 19 99uF 200uF 0 14F 8Hz 199 9uF 2000yF 2 0 5 8Hz 1999uF 20000uF 3 0 10 10uF 8Hz 1999 x 10 uF pF Pico Farad 10 F nF Nano Farad 10 F uF Micro Farad 10 F Erro de Zero 20pF Tens o de Teste Maximo 2 8V RMS Protec o de Sobrecarga Fusivel 0 1A 250V 8 MANUTEN O A Limpeza Periodicamente limpe a parte e
24. select the measurement range 3 Zero adjustment key Adjust the zero in measurements using low ca pacitance ranges 4 Negative input terminal 5 Positive input terminal Digital Capacitance Meter 16 6 OPERATION A Measurement Consideration 1 This capacitance meter was designed to measure capacitance of ca pacitors The meter will not measure Q factor of reactive components Wrong reading will be displayed when trying to reading the capacitance of resistors 2 When components are measured in circuit turn the circuit off and dis charge all capacitors before connect the test leads 3 Do not get the test leads close to each other black amp red 4 Instruments used in aggressive environments with dust must be cleaned periodically 5 Do not expose the capacitance meter to heat by long time 6 Before remove the battery cover or open the capacitance meter check if the meter is disconnected from the circuit and the rotary switch is in OFF position 7 To all measurements connect the black test lead to negative terminal and the red test lead to positive terminal of capacitor B Capacitance Measurement 1 Set the rotary switch to the desired measurement in accordance with the value of capacitor to be tested 2 Zero indication check at 200pF 2pF 20nF ranges check if the indication is zero If not adjust it by turning the Zero Adjustment key 3 Check the polarity when meas
25. uring polarized capacitors 4 Discharge completely the capacitor before measurement and if the measurement will be made in circuit turn off the power supply and discharge all capacitors before measurements 5 Connect the test leads black and red to and terminals and the alligator jaws to the terminals of component under test Or utilize MAK 2 adaptor to conect the capacitor to the capacitance meter 17 6 Make the reading in display The measurement is displayed with the corresponding units pF nF and pF indicated at the rotary switch Only at the 2000uF x10 the reading must be multiplied by 10 If the display shows the overrange indication 1 select the next upper range If the display shows one or more zero at the left of display select the next lower range to obtain better resolution AN Tninipa MC 153 2000 WF 18 NOTES a If the capacitance value is unknown start the measurement at 200pF range and select the next upper range until that the overrange indication is not displayed b A capacitor in short condition will display an overrange indication in all ranges A capacitor with low voltage leakage will present overrange readings or a capacitance value higher than the specified c Low capacitance measurements must be executed with short test leads to avoid parasite capacitance d When using optional test leads remember that the test leads introduces parasit
26. va Instrumentos usados em ambientes com poluentes devem ser limpos e enviados para calibra o periodicamente Antes detrocar a bateria ou o fus vel certifique se de que o instrumento esteja desligado e desconectado de qualquer circuito ou componente Para efetuar as medidas a ponta de prova preta deve ser conectada no terminal e a ponta de prova vermelha no terminal Antes da medida de capacitores eletrol ticos certifique se de este esteja totalmente descarregado Paragarantir precis o na medida n o permita que as suas m os fiquem em contato com os terminais durante a medida N o permita que o instrumento seja exposto a altas temperaturas e a incid ncia direta do raio solar para evitar a diminui o da vida til do LCD Nas medidas de capacit ncias muito baixas recomendado ajustar o zero da leitura com as pontas de prova em aberto antes da medida 2 CARACTER STICAS Leitura f cil e correta Alta precis o nas medidas Circuito interno de alta confiabilidade e durabilidade Prote o de sobrecarga incorporada Display LCD de baixo consumo e f cil leitura mesmo em ambientes com pouca luminosidade Leve e compacto para facilitar a opera o Indicador de bateria fraca no display 3 TERMOS NESTE MANUAL ADVERT NCIA identifica condi es ou a es que podem resultar em s rios ferimentos ou mesmo morte para o usu rio CAUTELA identifica condi es e a es
27. xterna do instrumento com pano macio umedecido em gua ou detergente neutro tomando cuidado para n o remover a serigrafia do painel frontal N o utilize produtos abrasivos ou solventes nem mesmo lcool B Troca de Bateria Quando o indicador de bateria fraca aparecer no display Troque imedia tamente a bateria para que o instrumento possa ser mantido em condi o normal de opera o Siga o seguinte procedimento para trocar a bateria a Verifique se o instrumento n o esta conectado em nenhum circuito Posicione a chave seletora em OFF e remova as pontas de prova dos terminais b Retire os tr s parafuso da tampa localizado na parte traseira do instru mento c Retire a bateria descarregada e troque por uma nova de mesma espe cifica o d Recoloque a tampa e os parafusos C Troca de Fus vel Quando nenhuma medida for poss vel provavelmente o fus vel interno este ja queimado neste caso siga o seguinte procedimento para trocar o fus vel a Verifique se o instrumento n o est conectado em nenhum circuito Posicione a chave seletora em OFF e remova as pontas de prova b Retire os tr s parafuso da tampa localizado na parte traseira do instru mento c Remova os parafusos do gabinete traseiro e abra o medidor cuidadosa mente d Substitua o fus vel do mesmo tipo e categoria 5x20mm 100mA 250V e Recoloque a tampa e os parafusos 10 9 GARANTIA O instrumento foi cuidadosamente ajustado