1. 50 mm s 50 mm s CA C CA CA CA E E LL CL E A CE EA E C E CA A E IA O LA A O LA A O ICA A A IA LL A IA LL A O A A E o A Triangular waveform at 2 Hz Square waveform at 2 Hz Electrical safety information Onda triangular a 2 Hz Onda cuadrada a 2 Hz Informaci n de seguridad el ctrica 50 mm s 50 mm s The TechPatient CARDIO simulator is a low voltage battery powered Ko E Ermua device that presents no electrical safety risk to its operator However Line noise addition Ripple noise addition when connected to diagnostic equipment in fault condition care should Adici n de ruido de l nea Adici n
2. pin patient cables To connect banana patient cables unscrew 25 mm s 25 mm s the metallic cap to expose the 4 mm jack Normal sinus rhythm Sinus tachycardia A hi signal alligator cable is also included It delivers a 200x Ritmo sinusal normal Taquicardia sinusal preamplified signal for premature circuit testing during electronic design This output is DC coupled to ease connection to analog digital converters eee ee El simulador TechPatient CARDIO se conecta al equipamiento de Sinus bradycardia Sinus arrhythmia Bradicardia sinusal Arritmia sinusal diagn stico por medio de sus 10 multi conectores de
3. biopotenciales Cada conector es compatible con cables de paciente tipo broche de 4mm tipo banana de 4mm y tipo pin de 2mm Para conectar cables de paciente tipo banana 50 mm s 50 mm s desenrosque el capuch n met lico para exponereljackde4mm GT Es Cuenta adem s con una salida de alta se al por cable cocodrilo Pulse waveform at 60 PPM Sinusoidal waveform at que entrega se al preamplificada 200x para el ensayo prematuro Onda de pulso a 60 BPM Onda senoidal de circuitos durante el dise o electr nico Esta salida se encuentra acoplada en DC para facilitar su conexi n a conversores anal gico digitales
4. Battery voltage range 6V to 9V Rango de tensi n de bater a a DC input voltage range 9V to 12V Rango de tensi n de entrada DC a General technical specifications Especificaciones t cnicas generales 20 BPM to 300 BPM 20PPM a 300 PPM Beat rate in BPM Frecuencia cardiaca en PPM Amplitude on Lead II with aVL as common onv1 6 for sine Wave mV 1 mv Amplitud en Derivaci n ll con aVL com n env1 6 para Senoidal 2 mV 4 mV Performance waveform frequenc to Praa ue 1 8Hz 120Hz Frecuencia de las ondas de performance Beat tate deviation n max es BPM heart rate 0 to 20 Desv o en la frecuencia card aca 16 max para frec card aca 300 PPM Amplitude deviation 4 max for 4mV amplitude 0 to 20 Desviaci n de amplitud 4 max para amplitud 4mV 200x Lead II plus DC 200x Deriv ll m s DC High signal output Salida de alta se al Output impedance to RL N terminal 2235 Q Unipolar Impedancia de salida al terminal RL N te Rise time from 10 to 90 Tiempo de crecimiento de 10 a 90 Sine waveform phase shift Defasaje de las ondas senoidales Triangular waveform phase shift Defasaje de las ondas triangulares Square waveform phase shift Defasaje de las ondas cuadradas Pulse amplitude manufacturing accuracy Exactitud de fabricaci n en amplitud de pulso Pulse interval manufacturing accuracy Exactitud de fabricaci n en intervalo de pulso Output impedance man
5. Ripple para comprobar el funcionamiento de los fiiltros 7 Introduce Baseline Wanderto check the functionality ofthe wave centering algorithms Introduzca Deriva en la L nea de base para comprobar el funcionamiento del algoritmo de centrado de onda 8 Select Pulse output a pulse rate of 60 PPM and remove deviation and noise Seleccione salida de Pulsos una frecuencia de 60 PPM y remueva el ruido y desv o 9 Calibrate time and amplitude in the device under test using the pulse rising edge interval 1 second and the amplitude measured at its middle point 1 mV Calibre el tiempo y amplitud en el dispositivo bajo ensayo utilizando el intervalo entre flancos ascendentes del pulso 1 segundo y la amplitud medida en su punto medio 1 mV 12 HE Instruments warrants the TechPatient CARDIO simulator from manufacturing defects in materials or workmanship when properly maintained and under normal use and service which means the measurement of any of its outputs without applying external signals to them The application of external signals such as a defibrillator shockwave is explicitly prohibited and will expirethis warranty HE Instruments sole obligation under this warranty shall be limited to the repair or replacement at its option of any defective part of said Patient Simulator which is the result of defective material or defective workmanship of parts installed by HE Instruments This warranty will expire 6 months from the date of d
6. de tuido de ripple be taken to avoid electrical shocks conducted through the patient cable El simulador TechPatient CARDIO es un dispositivo de baja tensi n alimentado a bater as que no presenta riesgos de seguridad el ctrica al operador Sin embargo cuando es HN eae Peay 25 mm s 50 mm s conectado a equipamiento de diagn stico en condici n de falla deben tomarse nosotro aa precauciones para evitar choques el ctricos conducidos atrav s del cable de paciente Baseline wander addition Muscle tremor addition 6 Adici n de deriva de l nea de base Adici n de temblor muscular 7 Device working conditions Condiciones de trabajo del dispositivo Detailed technical specifications Especificaciones t cnicas detalladas Temperature range soc t 452C Rango de temperatura a Relative humidity range non condensing 5 to 80 Rango de humedad relativa no condensada
7. a reemplaza a cualquier otra garant a impl cita o explicita No se garantiza la comerciabilidad o adecuaci n a un uso particular ni se extiende ninguna garant a para el uso del equipo que exceda los usos previamente detallados Cleaning and battery replacement Limpieza y reemplazo de bater a To replace the battery open its rear door remove the battery from its holder and replace it with a new one The device should never be used while the battery door remains open Only replace it with a PP3 compatible 9V battery Dispose discharged batteries in the appropriate environmentally clean way accordingto your government regulations Moisture should only be removed with a piece of dry cloth Avoid chemicals and other wet cleaning products Para reemplazar la bater a primero abra el compartimento trasero remueva la bater a del clip de conexi n y reempl cela por una nueva El dispositivo no debe usarse mientras el compartimento permanezca abierto Solo reempl cela por una bater a de 9V PP3 compatible Desh gase de las bater as descargadas de un modo ambientalmente adecuado en concordancia con las disposiciones gubernamentales El polvo debe ser removido nicamente con un trozo de pa o seco Evite productos qu micos y otros productos de limpieza h medos 13 Operator s notes Notas del operador 14 hen instruments For any further information regarding
8. definido Config Permite la selecci n de idioma de interfaz y frecuencia de l nea Y Indicates the ocurrence of a heartbeat It flashes a symbol when heartbeats are chaotic Y Indica la ocurrencia de un latido Parpadea el s mbolo cuando los latidos son ca ticos BPM Sets the mean Beats Per Minute PPM Selecciona el valor medio de las Pulsaciones Por Minuto R R Dev Sets the R R interval std deviation in percentage of the mean value n 3 Desv R R Selecciona el desv o est ndar del intevalor R R como porcentaje de su valor medio n 3 Frequency Sets the waveform Frequency in 5 Hzincrements Frecuencia Selecciona la Frecuencia de las ondas en incrementos de 5 Hz Amplitude Sets the waveform mean Amplitude in mV referenced to Lead Il Amplitud Selecciona la Amplitud media de las ondas en mV en referencia a la Deriv II Amp Dev Setsthe Amplitude standard deviation in percentage ofthe mean value n 3 Amp Desv Selecciona el desv o est ndar de la Amplitud como porcentaje del valor medio n 3 Base Setsthe percentage of baseline Base Selecciona el porcentaje de l nea de base Noise No Leavesthe generated waveform unchanged Line Adds line noise to the waveform 50 Hz 60 Hz Ripple Adds ripple noise to the waveform 100 Hz 120 Hz and harmonics Random Adds random noise with a near gaussian distribution BLWand Adds baseline wander usually associated with patient s motion or venti
9. elivery and repairs under this warranty shall be at repair facilities designated by HE Instruments Transportation expenses to and from the repair facility are to be born by the purchaser The warranty herein is expressly in lieu of any and all other warranties expresses or implied No implied warranty of merchantability is made and there are no warranties which extend the use of the Patient Simulator for purposes beyond the description hereof HE Instruments garantiza el simulador TechPatient CARDIO ante defectos de fabricaci n en materiales o mano de obra siempre que ste sea utilizado conforme a las condiciones normales de uso y servicio A saber la medici n de sus salidas sin la aplicaci n de se ales externas La aplicaci n de se ales el ctricas externas al mismo como el shock de un desfibrilador queda expl citamente prohibida e invalida esta garant a La nica obligaci n de HE Instruments bajo la presente garant a ser limitada a la reparaci n o reemplazo seg n su conveniencia de cualquier parte defectuosa del mencionado Simulador de Paciente que resulte de un defecto en los materiales ocomponentes instalados por HE Instruments Esta garant a expira a los 6 meses contados desde la fecha de env o del equipo y las reparaciones bajo la misma deber n realizarse nicamente en las dependencias designadas por HE Instruments El costo del traslado del equipo a dichas dependencias ser responsabilidad del comprador Esta garant
10. for a detailed and specific procedure A continuaci n se expone un procedimiento gen rico de verificaci n de equipamiento de diagn stico por ECG Dirijase al manual de servicio de su equipo para un procedimiento detallado y espec fico 1 Power up the TechPatient CARDIO simulator and select ECG output 80 BPM 1mV amplitude without deviation or noise Encienda el simulador TechPatient CARDIO y seleccione salida ECG 80 PPM amplitud 1mV sin desviaci n ni ruido 2 Connect the 12 5 or 3 leads according to the device under test Conecte las 12 5 o 3 derivaciones de acuerdo al dispositivo bajo ensayo 3 The device should indicate the detected ECG on every lead the heart beats and a measured beat rate of 80 BPM El dispositivo debe indicar el ECG detectado en cada derivacion los latidos cardiacos y una medicion de frecuencia cardiaca de 80 PPM 4 Remove one terminal at a time to test the patient cable disconnection alarm Remueva un terminal por vez para ensayar la alarma de desconexi n de cable de paciente 5 Introduce up to 5 deviation in both rate and amplitude to check the beat detector stability The beat rate measurement should remain unaltered Introduzca un desvio de hasta 5 tanto en amplitud como frecuencia cardiaca para comprobar la estabilidad del detector de latidos La medici n no debe sufrir alteraciones 6 Introduce Line and Ripple noise to checkthe functionality ofthe input filters Introduzca ruido de L nea y
11. he TechPatient instruments CARDIO VERSION 3 2 Operators Manual The described device is to be used by technically skilled personnel Manual del Operador El dispositivo aqu descripto solo debe ser usado por personal t cnico capacitado Contents Contenido Contents Contenido 3 FCC Exemption Excenci n FCC 4 Electromagnetic compliance information Informaci n de compatibilidad EM _____ 4 Usage of a Patient Simulator Usos de un Simulador de Paciente 5 The 12 lead ECG El ECG de 12 derivaciones 5 Simulator connection Conexi n del simulador 6 Electrical safety information Informaci n de seguridad el ctrica 6 Simulated waveforms Formas de onda simuladas 7 Device working conditions Condiciones de trabajo del equipo 8 General technical specifications Especificaciones t cnicas generales 8 Detailed technical specifications Especificaciones t cnicas detalladas 9 Keyboard and screen navigation Teclado y navegaci n en pantalla 10 Menu options Opciones del men 10 11 Equipment verification procedure Procedemiento de verificaci n de equipos 12 Warranty information Informaci n de garant a 13 Cleaning and battery replacement Limpieza y reemplazo de bater as 13 Operator s notes Notas del operador 14 FCC Exemption Exenci n FCC The device is exempt from FCC regulations under Part 15 Section 103 c El dispositivo se encuentra exento de la
12. lation Tremor Adds noise associated with muscle tremor Ruido No Dejala forma de onda generada sin cambios L nea Agrega ruido de l nea a la forma de onda 50 Hz 60 Hz Ripple Agrega ruido de ripple a la forma de onda 100 Hz 120 Hz y arm nicas Aleat Agrega ruido aleatorio con una distribuci n cuasi gaussiana Deriva Agrega deriva en la linea de base usualmente asociada al movimiento o ventilaci n del paciente Temblor Agrega ruido asociado al temblor muscular Common Selects the reference common lead when generating two phased waveforms Com n Selecciona la derivaci n com n de referencia cuando se generan ondas bif sicas Light Select whether the lights must remain on off or start only when touching the keypad Luz Selecciona si la luz debe permanecer encendida apagada o encenderse nicamente cuando se presiona unatecla Sleep Selects whether the device must switch off after 10 minutes without user intervention Suspender Elige si el dispositivo debe o no suspenderse luego de 10 minutos sin intervenci n del usuario Battery Indicates the remaining percentage of battery charge Bater a Indica el porcentaje restante de la bater a 11 Equipment verification procedure Procedimiento de verificaci n de equipos Warranty information Informacion de garantia The following explains a generic verification procedure for ECG based diagnostic equipment Please refer to your equipment s service manual
13. par metros entra al actual para cambiar su valor Tras cambiar un valor regresa a la lista de par metros The up and down keys navigate the list of parameters while browsing or edit the current value The pointer indicates the current position Las teclas arriba y abajo navegan por la lista de par metros o cambian el valor de uno de ellos El puntero en pantalla indica la posici n actual Menu options Opciones del menu ECG Generates 12 Lead realistic cardiac waveforms Sin Generates three phase sinusoidal waveforms on 3 leads and single phase sinusoidal waveforms on the precordial leads Tri Quad Generates two phase triangular square waveforms referenced to a common lead Pulses Generates a two phase pulsed waveform with the same features as the cardiac waveform Waveforms are referenced to acommon lead Base Generates a baseline of a predefined mean value Config Enables the selection of interface language and line frequency ECG Genera ondas card acas realistas en 12 derivaciones Sin Genera ondas senoidales trif sicas en 3 derivaciones y ondas senoidales monof sicas en las derivaciones precordiales Tri Quad Genera ondas triangulares cuadradas bif sicas referenciadas a una derivaci n com n Pulsos Genera una onda pulsada bif sica con las mismas caracter sticas de la onda card aca Las ondas est n referenciadas a una derivaci n com n Base Genera una l nea de base con un valor medio pre
14. ram is a representation of the heart s electrical activity recorded from ten electrodes on the body surface It provides spatial information about the heart s internal activity each of the 12 leads representing a particular orientation in space It s an improvement from the original 3 and 5 leads ECG therefore 12 leads simulation is compatible with 3 and 5 leads diagnostic equipment El ECG estandar de 12 derivaciones es una representaci n de la actividad el ctrica del coraz n grabada a partir de diez electrodos sobre la superficie corporal Provee informaci n espacial acerca de la actividad interna del coraz n representando cada derivaci n una orientaci n particular en el espacio Se trata de una mejora del ECG convencional por lo tanto la simulaci n en 12 derivaciones es compatible con el equipamiento m dico de 3 y 5 derivaciones 3 Simulated waveforms Simulator connection Formas de onda simuladas Conexi n del simulador The TechPatient CARDIO simulator connects to diagnostic equipment through its 10 biopotential multi connectors Each connector is compatible with 4mm snap 4mm banana and 2mm
15. s regulaciones de la FCC bajo la normativa Parte 15 Secci n 103 c Electromagnetic compliance information Informaci n de compatibilidad EM While this simulator is compliant with the applicable regulatory EMC requirements there is no guarantee that interference will not occur in a particular installation To minimize the potential for the hardware to cause interference to radio and television reception or to experience unacceptable performance degradation install and use this hardware in strict accordance with the instructions in this operator s manual If this hardware does cause interference with licensed radio communications services or other nearby electronics which can be determined by turning the hardware off and on you are encouraged to try to correct the interference by one or more of the following measures e Reorient the antenna of the receiver the device suffering interference e Relocate the transmitter the device generating interference with respect to the receiver e Plug the transmitter into a different outlet so that the transmitter and the receiver are on different branch circuits Some hardware may require the use of a metal shielded enclosure windowless version to meet the EMC requirements for special EMC environments such as for marine use or in heavy industrial areas Refer to the hardware s user documentation and the DoC for product installation requirements When the hardware is connected to a
16. test object or to test leads the system may become more sensitive to disturbances or may cause interference in the local electromagnetic environment Operation of this hardware in a residential area is likely to cause harmful interference Users are required to correct the interference at their own expense or cease operation of the hardware Changes or modifications not expressly approved by HE Instruments could void the operator s right to operate the simulator under the local regulatory rules 4 Usage of a Patient Simulator Uso de un Simulador de Paciente A patient simulator is an electronic device that through the simulation of specific parameters in preset conditions is used for testing verification and calibration of diagnostic equipment The TechPatient CARDIO simulator is specifically designed to test 12 leads ECG diagnostic equipment such as ECG machines patient monitors and Holter recorders among others Un simulador de paciente es un dispositivo electr nico que mediante la simulaci n de par metros espec ficos bajo condiciones preestablecidas permite ensayar verificar y calibrar equipamiento de diagn stico El simulador TechPatient CARDIO esta dise ado espec ficamente para el ensayo de equipamiento de diagn stico ECG de 12 derivaciones tales como electrocardi grafos monitores de paciente y grabadores Holter The 12 Lead ECG El ECG de 12 Derivaciones The standard 12 lead electrocardiog
17. this or any other HE Instruments product contact us at Por cualquier otra informaci n acerca de este o cualquier otro producto de HE Instruments cont ctenos en http www heinstruments com support heinstruments com 1 866 921 4971 54 911 5841 9098 All rights reserved 2011 HE Instruments Todos los derechos reservados 2011 HE Instruments
18. ufacturing accuracy Exactitud de fabricaci n de la impedancia de salida Rise time manufacturing accuracy Exactitud de fabricaci n del tiempo de crecimiento Pulse amplitude calibrated accuracy Exactitud calibrada en amplitud de pulso Pulse interval calibrated accuracy Exactitud calibrada en intervalo de pulso Average electronics current consumption Consumo de corriente promedio de la electr nica Average current consumption of LCD backlight Consumo de corriente promedio de la luz del LCD 1 3 ms Eq B W 270 Hz 1202 aVR aVL aVF 02 V1 V6 1802 aVR aVL aVF PIES VG 1802 aVR aVL aVF 02 V1 V6 2 40uV a 25 5 2C 1 a 25 5 2C 1 5 2 25 5 2C 12 a 25 5 2C 0 5 20uV A e 0 1 1ms i a ds 16 mA 10 mA Calibrated accuracies only apply to calibrated devices for the 12 months following the purchase of a calibration certificate Las exactitudes calibradas solo aplican a aquellos dispositivos calibrados en los 12 meses posteriores a la adquisici n del certificado de calibraci n g Mode Modo 10 Keyboard and screen navigation Teclado y navegaci n en pantalla Hold for more than 2 seconds to turn the device on and off Mantenga presionado por m s de 2 segundos para encender o apagar el equipo When browsing parameters it enters the current to change its value After changing a value it returns to the parameter browser Al elegir