Home
MEDICAL EQUIPMENT/ EQUIPO MÉDICO
Contents
1. Blades Stainless blades for use with pediatric patients 2 to 10 years old At the very least it should include Curved blade Macintosh No 2 and No 3 Straight blade Miller No 1 and No 2 Case Compact Easy to clean With interior compartments to secure instruments in position With zipper or superior closing mechanism All equipment should adhere to internationally recognized manufacturing standards such as UL AAMI ANSI ASTM ISO or similar Compacto Facil de limpiar Con compartimientos interiores para mantener los instrumentos en posici n e Con cierre de cremallera o sistema mejorado El equipo debe cumplir con normas de construcci n reconocidas internacionalmente tales como UL AAMI ANSI ASTM ISO o similares Electrical Powered by rechargeable Funcionamiento a base de bater as recargables Characteristics batteries Incluye sistema de carga de bater as Caracter sticas Charger should also be El ctricas included Mechanical Constructed of 304 grade Construido de acero inoxidable grado 304 o mejor Characteristics stainless steel or better La unidad deber estar bien construida con material Caracter sticas The unit should be well resistente y durable que permita el uso y limpieza t pica de Mec nicas manufactured with resistant todas las partes del equipo and durable material that permits the use and cleaning of all the parts of the equipment Receptions of
2. TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Equipment Graves Vaginal Speculum Large Esp culo vaginal grande Equipo Description Material Stainless Steel grade 304 or Material Acero inoxidable Descripci n better Dimensiones aproximadas 105 X 33 mm Type Graves Size Large Approximate dimensions 105 x 33 mm Electrical N A No aplican characteristics Caracter sticas El ctricas Mechanical All instruments must be made of Todo el instrumental debe ser de acero inoxidable Characteristics stainless steel grade 304 or better grado 304 o mejor Caracter sticas Mec nicas Installation Delivery in proper functioning order Deber entregarse de conformidad Conditions Condiciones de Instalaci n Technical Information Certificate of Quality Certificado de calidad required Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de un a o a partir de la entrega de conformidad Unidad de Proyectos MSPAS Page 66 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER RENGLON DESCRIPTION DESCRIPCION QUANTITY CANTIDAD 28 Graves Vaginal Speculum Medium Esp culo vaginal tipo Grave mediano 70 TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS
3. ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Informaci n T cnica Requerida Electrical Characteristics N A No Aplica Caracter sticas El ctricas Mechanical Characteristics N A No Aplica Caracter sticas Mec nicas Technivcallnformation Required N A No Aplica Warranty Garant a One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de warranty from date of satisfactory un a o a partir de la entrega en el almac n delivery correspondiente Unidad de Proyectos MSPAS Page 88 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Mobile IV Stand Stainless Steel 40 14 Porta sueros rodable de acero inoxidable TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Article Articulo Mobile IV Stand Stainless Steel Porta sueros rodable de acero inoxidable Description e Metal pedestal with double Pedestal met lico con doble ganchos altura ajustable 124 a Descripci n hooks 205 mm y 5 rodos comerciales tipo bola de 41 2 mm e Adjustable height from 124 mm 15 8 de di metro con espiga roscada acabado cromado to 205 mm e 5 commercial type castors ball type 41 2 mm 15 8 diameter threaded for easy screw in chrome plated finish Electrical N A No aplican Characteristics
4. 1 Pinza Kocher curva de 15 cm 1 Tijera Mayo recta de 15 cm 1 Tijera Mayo curva de 15 cm 1 Tijera Lister abotonada de 15 cm 1 Porta aguja Heagar 1 Copa de acero inoxidable de 6 onzas Vasija circular de acero inoxidable para depositar placenta de 30 cm de di metro por 15 cm de alto Unidad de Proyectos MSPAS Page 64 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Electrical N A No aplican Characteristics Caracteristicas El ctricas Mechanical All instruments should be of Stainless Todo el instrumental debe ser de acero inoxidable Characteristics Steel graded 304 or better grado 304 o mejor Caracteristicas Mecanicas Installation Conditions Delivery in proper functioning order Debera entregarse de conformidad Condiciones de Instalaci n Technical Information Certificate of Quality Certificado de calidad Required Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de un warranty from date of satisfactory a o a partir de la entrega de conformidad delivery Unidad de Proyectos MSPAS Page 65 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Graves Vaginal Speculum Large 27 70 Esp culo vaginal tipo Grave grande
5. Article Art culo Phlebotomy chair Sill n para toma de muestras Description Chair for taking blood samples from Silla para toma de muestras de sangre de pacientes Descripci n outpatients ambulatorios With two adjustable arm rests with a Con dos brazos ajustables con mecanismo para subir la parte mechanism for raising the back portion trasera del brazo a la posici n ptima para venipuntura of the arm rest for optimal positioning Brazo de superficie plana para evitar que el codo se doble during blood draw acojinado con espuma de 1 de espesor de poliuretano forrado Flat surfaced arm rest to prevent the de tapiz pl stico color caf sin costuras lavable elbow from bending padded with 1 Con cajones laterales para almacenar materiales con abertura thick polyurethane foam covered in lateral con divisiones desmontables en cada una de las seamless brown plastic washable gavetas para selecci n de materiales fabric With side drawers for storing materials side opening removable divisions in each of the drawers for material selection Electrical N A No aplican Characteristics Caracter sticas El ctricas Mechanical e Chair structure made of chrome plated La estructura de la silla de acero cromado Characteristics steel Asiento acolchonado de espuma de poliuretano de 2 de Caracter sticas e Seat padded with polyurethane foam espesor forrado con tapiz plastico sin costura color caf Mecanicas 2 thick covered with seamless l
6. ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 scale regulated by two stainless steel dials Foam mattress 1 thickness with durable and easy to clean cover preferably with child friendly motif With accessory to place a paper towel Mechanical Platform made of high durability Tablero de material plastico de alta durabilidad resistente a los Characteristics plastic shock and scratch resistant impactos y rayones Caracteristicas Topes pl sticos de alta duraci n con deslizamiento suave para Mec nicas Length measurement sliding system cabeza y pies Estos topes no deben de perder su with durable stoppers and smooth perpendicularidad con el uso sliding at both head and foot area These knobs should not loose their perpendicular nature with use of device El gabinete deber estar hecho de metal resistente The cabinet should be made of Con sistema de contra pesos y o resortes con peso deslizante resistant metal Counter weight Con escalas de f cil lectura system and or springs with weight Pintada al horno lavable displacement Easy to read graduation Oven painted washable Conditions of Device should be delivered in proper Deber entregarse funcionando y calibrada en las Unidades de Reception functioning order to the Salud correspondiente a entera satisfacci n del m dico Director o Condiciones de corresponding Health Units to the de la persona
7. Graves Vaginal Speculum Virginal Esp culo vaginal virginal Description Descripci n Material Stainless Steel grade 304 or better Type Graves Size Virginal Approximate dimensions 75x17 mm Material Acero inoxidable Dimensiones aproximadas 75 x 17 mm Electrical characteristics Caracter sticas El ctricas N A No aplican Mechanical characteristics Caracter sticas Mec nicas All instruments must be made of stainless steel grade 304 or better Todo el instrumental debe ser de acero inoxidable grado 304 o mejor Installations Conditions Delivery in proper Deber entregarse de conformidad Condiciones de functioning order Instalaci n Technical Information Certificate of Quality Certificado de calidad Required Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de un a o a partir de la entrega de conformidad Unidad de Proyectos MSPAS Page 70 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 MOBILIARIO CL NICO Unidad de Proyectos MSPAS Page 71 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Stainless Steel bucket with Castors 31 Balde met
8. 240 F to 132 C 270 F Pressure Range 0 30 PSI Work Cycles Fluids and materials Timer Control 0 60 minutes adjustable Reservoir Tank Capacity 4 5 liters The cabinet included with the equipment where it will be mounted will be adjusted to fit perfectly to the same should be metal with a shelf two doors with sufficient space to store materials Cabinet will have oven paint be washable and Electric e Voltage 220 VAC 3H Voltaje 220 VAC 3H Characteristics e Frequency 60 Hertz Frecuencia 60 Hertz Caracteristicas e Phases 1 Fases 1 El ctricas e Power Output 4 6 kW Potencia 4 6 Kilovatios e Electrical Safety Type H according to UNE Tipo de seguridad el ctrica H seg n norma UNE 20 613 or equivalent 20 61 3 equivalente l e Supplier will provide a female socket El suministrante proveer el tomacorriente hembra connector according to the offered seg n el conector del equipo ofertado el cual equipment which must be delivered to the deber ser entregado a la UACI inmediatamente UACI immediately after receipt of legalized despu s de recibir copia del contrato legalizado contract Mechanical Sanitizer for mounting on cabinet with single Esterilizador para montaje sobre gabinete de una Characteristics door cylindrical chamber nominally designed puerta con c mara cil ndrica dise ada Caracter sticas for 50 PSI fully 304 grade stainless steel that nominalmente para 50 PSI completamente de
9. Mec nicas complies with ASME and ASTM standards acero inoxidable 304 que cumpla con las normas ASME y ASTM Con las siguientes caracter sticas m nimas Capacidad de c mara 60 75 litros aprox Dimensiones aproximadas de la c mara 380mm di metro x 660mm largo Rango de temperatura 115 C 240 F a 132 C 270 F Rango de presi n 0 a 30 PSI Ciclos de trabajo L quidos y materiales Control de tiempo 0 a 60 minutos ajustable Capacidad aproximada de tanque reservorio 4 5 litros El gabinete incluido con el equipo en el cual ir montado se ajustar perfectamente a ste debe ser met lico con un entrepa o de dos puertas con espacio suficiente para almacenar material pintado Unidad de Proyectos MSPAS Page 23 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 resistant to disinfectant liquids al horno lavable y resistente a l quidos de desinfecci n Conditions of Vendor will provide all the information En caso de ser adjudicado el suministrante Reception concerning the type of electrical circuit along proveer toda la informaci n concerniente al tipo de Condiciones de with necessary protection according to circuito en el cual se deber conectar el equipo con Recepci n e manufacturer s recommendations necessary sus protecciones el ctricas correspondientes Instalaci n to connect the equipment This information s
10. Una pera de hule con v lvula de control Electrical Characteristics Caracter sticas El ctricas N A No aplican Mechanical Characteristics Caracter sticas Mec nicas Pressure range 0 300 mm of Hg calibration 3mm Hg Flexible material adult cuff covered in resistant fabric Rango de presi n a medir 0 300 mmHg 3 mmHg Manga para adulto de material flexible cubierta con tela resistente Conditions of Reception Device should be delivered fully Deber entregarse en las Unidades de Salud Condiciones de Recepci n assembled and in proper correspondiente a entera satisfacci n del m dico Unidad de Proyectos MSPAS Page 44 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 functioning order to the corresponding Health Units to the satisfaction of the Medical Director or the designated party Director o de la persona que ste designare para tal efecto Technical Information Operation Manual Manual de Operaci n Required Parts Manual Manual de Partes Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Written commitment from the supplier to have spare parts in stock for a period of a minimum of five 5 years De un a o contra desperfectos de fabricaci n a partir de la fecha de puesta en funcionamiento del equipo Compromiso d
11. tipo gaveta en la zona de trabajo Con respaldo para tres posiciones y piesero ajustable Con protectores de hule antideslizante en las patas Dimensiones aproximadas 1 80 m largo x 0 55 m ancho x 0 84 m de alto Unidad de Proyectos MSPAS Page 38 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Electric Cabinet section should have two Deber contar en la zona del gabinete con dos tomacorriente Characteristics hospital grade female double hembra dobles polarizados grado hospitalario con protecci n Caracter sticas polarized electrical sockets with 20 t rmica de 20 amperios a 120 VAC El ctricas amp thermal protection and 120V Tipo de seguridad el ctrica B seg n norma IEC 601 1 UNE capacity 20 613 equivalente Electrical safety B according to UNE 20 613 IEC 601 1 standards or equivalent Mechanical Built of metallic structure Armada en estructura met lica Characteristics Materials resistant to disinfectant De material resistente a l quidos de desinfecci n Caracter sticas solutions Pintura esmalte horneable o en polvo ep xica de aplicaci n Mec nicas Enamel oven dried paint or epoxy electrost tica coated electrostatic paint Resistente a la corrosi n Rust resistant Conditions of Device should be delivered fully Deber entregarse ensamblada en las Unidades de Salud Reception assembled and in proper functioning correspondiente a entera
12. Approximate vacuum range 7 5 mm to 150 mm Hg Electrical e Voltage 120 VAC Voltaje 120 VAC Characteristics e Frequency 60 Hz Frecuencia 60 Hz Caracteristicas e Phases 1 Fases 1 El ctricas e Power range 1 8 to 1 2 HP Potencia Rango 1 8 1 2 HP e Male Socket Hospital grade Tomacorriente macho Polarizado grado hospitalario F polarized Tipo de seguridad el ctrica B seg n norma IEC 601 1 O e Electric safety B according to UNE 20 613 9 equivalente A nz standard IEC 601 1 or UNE 20 613 Longitud aproximada del cord n de alimentaci n 3 m or equivalent e Approximate length of power cord 3 meters Mechanical Mobile self supporting structure with Equipo m vil autosoportado con sistema de transporte con Characteristics minimum 4 castors no less than al menos 4 rodos conductivos di metro no menor a 12 5 Caracteristicas 12 5 cm in diameter and brake in at cm y dispositivo de freno en al menos dos de ellos Mec nicas least two of them Carcasa de polietileno polipropileno termoconformado u otro material de mejor calidad resistente a la corrosi n y de f cil limpieza Rango aproximado de vac o 7 5 mm a 150 mm Hg Unidad de Proyectos MSPAS Page 7 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Conditions for Device should be delivered in proper Debera entregarse funcionando en las Unidades de Salud reception functioning order to the corre
13. Device should be delivered Deber entregarse a entera satisfacci n de la Jefatura del Condition fully assembled and in proper rea seg n matriz de distribuci n Condiciones de functioning order to the Unidad de Proyectos MSPAS Page 35 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Recepci n corresponding Health Units to the satisfaction of the Medical Director or the designated party Technical Information Operation Manual Manual de operaci n Required Parts Manual Manual de partes Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Written commitment from the supplier to have spare parts in stock for a period of a minimum of five 5 years Garant a contra desperfectos de fabricaci n de un a o a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del suministrante en existencia de repuestos para un per odo m nimo de cinco a os Unidad de Proyectos MSPAS Page 36 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Neurological Reflex Hammer 13 9 Martillo de reflejos TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Equipment Neurological Reflex Hammer Martillo de reflejos Equip
14. Equipment Graves Vaginal Speculum Medium Esp culo vaginal mediano Equipo Description Material Stainless Steel grade 304 Material Acero inoxidable Descripci n or better Dimensiones aproximadas 95 x 30 mm Type Graves Size Medium Approximate dimensions 95 x 30 mm Electrical N A No aplican Characteristics Caracter sticas El ctricas Mechanical All instruments must be made of Todo el instrumental debe ser de acero inoxidable grado 304 Characteristics stainless steel grade 304 or better o mejor Caracter sticas Mec nicas Intallation Delivery in proper functioning order Deber entregarse de conformidad conditions Condiciones de Instalaci n Unidad de Proyectos MSPAS Page 67 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Technical Certificate of Quality Certificado de calidad Information Required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de un a o a Garant a warranty from date of satisfactory partir de la entrega de conformidad delivery Unidad de Proyectos MSPAS Page 68 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 NUMBER RENGLON DESCRIPTION DESCRIPCION QUANTITY CANTIDAD Graves Vaginal Speculum Small 29 35 Esp culo vaginal tipo Grave pequeno TECHNICAL SPECIFICATIONS ESP
15. Gynecological Table 14 14 Mesa Ginecol gica TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS minimum characteristics e Square tubular metal work of 1 with 3 4 reinforcement tube e Sheet metal cabinet with a shelf door and one or two drawers e Oven or electrostatic painting e Two chrome plated stirrups adjustable in height and width e Mattress pad 2 thick in 3 sections made of durable washable material removable section in work area e Stainless steel tray in the work area e Adjustable foot section and back section three positions e Antiskid rubber stoppers on feet e Approximate dimensions 1 80 m L x 0 55 m W x 0 84 m H Equipment Gynecological Table Mesa Ginecol gica Equipo Description Table for clinical and gynecological Mesa Ginecol gica para examen cl nico y ginecol gico con Descripci n examination with the following las siguientes caracter sticas m nimas Estructura met lica tubular cuadrada de 1 con refuerzo de tubo cuadrado de Gabinete de l mina de acero pintado al horno o electrost ticamente con un entrepa o con puerta Con una o dos gavetas Dos estribos cromados y ajustables en altura vertical y horizontal Superficie acolchonada con espuma de 2 de espesor tapizada en tres planos con material lavable y resistente a soluciones antis pticas Bocado desmontable en la zona de trabajo Bandeja de acero inoxidable
16. Patient Preparation Table 39 7 Mesa para preparacion de pacientes TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Article Articulo preparation Auxiliary hospital table for various uses large for use for patient Mesa auxiliar hospitalaria para usos diversos grande mesa para preparaci n de pacientes Description Descripci n Structure in 1 32 steel sheeting supported by industrial square shaped steel tube 1 wide Top covered in plastic laminate anti rust treatment oven painted with poweder paint color beige brown with two keys mounted on sliding extension arms with handles four 4 legs 1 Y X 1 grey color finish Approximate Dimensions Length 1 15 m Width 0 73 m With two 2 drawers central lock With anti slip rubber stoppers on all Steel tube 18 gauge 32 X 32 mm Estructura en l mina de acero de 1 32 de espesor apoyada en tubo industrial de hierro cuadrado de 1 de lado cubierta en su superficie de pl stico laminado tratada con anticorrosivo previa pintura pintada al horno con pintura en polvo colores beige caf Con dos gavetas laterales con cierre simult neo con dos llaves montadas sobre brazos de extensi n progresiva a la derecha con haladeras Con tacos antideslizantes en las 4 bases Dimensiones aproximadas e Largo 1 15m e Ancho 0 73 m e Alto 0 75 m Height 0 75 m Unidad de Proyectos MSPAS Page 87 of 94
17. Selecting Keys With programs for measuring and evaluating in each of the medical specialties above mentioned Automatic selection of programs With built in software for each of the requested transducers which must be updatable during the warranty period Outputs ports for external monitors and video recorder conventional DVD format or upgraded technology with USB 2 0 port Cabinet Metal cabinet which can withstand the equipment with compartments for peripheral equipment voltaje stabilizer printer etc on castors for easy moving around and a system of mechanical breaks Transducers Multifrequency transducer with a range of 2 5 to 12 MHz with the following 1 endovaginal transducer 1 transducer for small parts DE 7 5 12 MHz 1 linear transducer for general applications use 1 convex transducer 1 linear transducer for general applications and mammography Doble imagen Imagen congelada Panel de mando Teclado alfanum rico en Espanol Trackball mouse Teclas selectoras iluminadas Con programas de medici n y evaluaci n en cada una de las especialidades m dicas especificadas Selecci n autom tica de los programas Con software incorporado para cada uno de los transductores solicitados que sea actualizable durante el periodo de garant a Con salidas para monitores externos y a videograbadora formato DVD convencional o tecnolog a mejorada con salida USB 2 0 Gabinete
18. Set de Oto oftalmoscopio TECHNICAL SPECIFICATION ESPECIFICACIONES TECNICAS Equipment ENT Diagnostic Set Set de Oto oftalmoscopio Equipo Description Diagnostic set that consists of Set de Diagn stico que consta de Descripci n e One stainless steel handle Un mango con bater a recargable de acero inoxidable with rechargeable battery funcionamiento a bater as tama o C de 1 5 VDC capaz de battery size C of 1 5 VDC for acoplarse y accionar a hook up andf function as Un otoscopio de diagn stico completo con cuatro esp culos e A complete diagnostic reusables como m nimo de polipropileno tama os otoscope with at least aproximados de 2 3 4 y 5 mm con l mpara hal gena de four reusable luz fr a e iluminador de garganta speculums at least of Un Oftalmoscopio est ndar con l mpara hal gena de luz fr a polypropylene sin reflejos con 20 lentes como m nimo desde 25 a 40 approximate sizes of 2 dioptr as con apoyo de goma para la ceja dise o de lentes 3 4 and 5 mm with iluminados halogen cold light and El set de instrumentos deber ir todo en un estuche throat illuminator compacto seguro y resistente con cierre de cremallera u e A standard otro sistema ademas de dos l mparas hal genas de Ophthalmoscope with repuesto halogen cold light with at least 20 lenses from 25 to 40 diopters with rubber eyebrow support illuminated lense design e Compact carrying case e Two replacem
19. date of satisfactory la fecha de puesta en funcionamiento del equipo delivery Compromiso del suministrante en existencia de repuestos para un per odo m nimo de 5 a os Written commitment from the supplier to have spare parts in stock for a period of a minimum of five 5 years Unidad de Proyectos MSPAS Page 49 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Digital Ear Thermoneter 20 14 Termometro Auricular Digital TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Equipment Digital Ear Thermometer Term metro Auricular Digital Equipo Description Digital thermometer for measuring Term metro para medici n de la temperatura corporal Descripci n body temperature Caracter sticas Characteristics e Rango de medida 34 44 C Precisi n 0 2 C e Measurement range 34 C 44 C e Con memoria de las 10 ultimas medidas e Allowable deviation 0 2 C e Pantalla LCD de 4 d gitos e Memory storage capacity up to 10 e Apagado autom tico last measurements e Indicador de carga y de baterias agotadas e 4 digit LCD screen e Automatic shut off Accesorios e Battery charge readout e Estuche e 50 Protectores desechables Accessories e 2 pares de bater as e 1 case e 50 disposable protectors e 2 pairs of batteries Electrical N A No aplican Characteristics Caracteristicas El ct
20. gico hidrof bico para evitar contaminaci n Con frasco preferentemente de vidrio o de policarbonato autoclavable con capacidad de 1000 ml con escala indeleble con sistema de protecci n contra flujo y dispositivo de seguridad para evitar rebalse Debe incluir man metro de presi n Bajo nivel de ruido El equipo debe estar construido de acuerdo a normas de seguridad y estandares para servicio hospitalario Ademas el equipo debe cumplir con normas de construcci n reconocidas internacionalmente como UL ASTM NEMA ISO IEC VDE JIS ANSI DIN o similares Accesorios incluidos 1 Tubo conductivo pl stico transparente y resistente para aspiraci n de 1 4 1 Frasco extra de 1000 ml 4 Filtros bacteriol gicos hidrof bico descartables Unidad de Proyectos MSPAS Page 6 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 accordance with standards of quality and safety for hospital use In addition the device must meet internationally recognized standards of manufacture such as UL ASTM NEMA ISO IEC VDE JIS ANSI DIN or similar Additional accessories e 1 transparent and resistant plastic conductive aspiration tube of 1 4 e 1 extra Bottle from 1000 ml e 4 bacteriological hydrophobic disposable filters Casing made of thermoformed polyethylene polypropylene or another material superior in quality rust resistant and easily cleaned
21. inches deep e 20 inches high from seat to floor e Ruedas traseras con un aro paralelo que sirva para que el paciente movilice la silla e Con capacidad para soportar peso de hasta 250 libras e Estructura met lica de facil limpieza anticorrosivo y resistente a la aplicaci n de desinfectantes de uso hospitalario e La tapicer a debe ser de nylon o material resistente al enmohecimiento y retardante a la llama e Apoya pie en aluminio pulido e Pu os de empuje forrados de hule e Apoya brazos acolchonado e Dimensiones aproximadas del asiento 20 pulgadas de ancho 18 pulgadas de profundidad 20 pulgadas del asiento al piso de alto Condiciones de Device should be delivered in proper functioning Deber entregarse a entera satisfacci n de la Recepci n order according to distribution matrix and area Jefatura del rea seg n matriz de distribuci n Director Warranty Two 2 year manufacturers defect warranty from Garant a contra desperfectos de fabricaci n de dos Garant a date of satisfactory delivery a os a partir de la fecha de entrega de conformidad Unidad de Proyectos MSPAS Page 92 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Phlebotomy Chair 42 7 Sill n para toma de muestras TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS
22. lactantes 0 2 a os 4 7 years Una pera de hule con valvula de control Rubber cuff for adult Rubber bulb control valve Electrical N A No aplican Characteristics Caracteristicas El ctricas Mechanical Pressure range 0 300 mm of Hg calibration Rango de presi n a medir 0 300 mmHg 3 mmHg Characteristics 3mm Hg Manga para ni os de material flexible cubierta con Caracter sticas Flexible material pediatric cuff covered in tela resistente Mec nicas resistant fabric Unidad de Proyectos MSPAS Page 46 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Conditions of Device should be delivered fully assembled Debera entregarse en las Unidades de Salud Reception and in proper functioning order to the correspondiente a entera satisfacci n del m dico Condiciones de corresponding Health Units to the Director o de la persona que ste designare para tal Recepci n satisfaction of the Medical Director or the efecto designated party Technical Operation Manual Manual de Operaci n Information Parts Manual Manual de Partes Required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect warranty De un a o contra desperfectos de fabricaci n a Garant a from date of satisfactory delivery partir de la fecha de puesta en funcionamiento del equipo Written commitment from the supplier to have Compromiso del suministrante en existencia de spare
23. lico de acero inoxidable con 14 rodos TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Article Art culo Stainless Steel Bucket with Castors Balde met lico de acero inoxidable con rodos Description Stainless Steel bucket to place contaminated Balde met lico para colocar material Descripci n material contaminado p Mechanical Characteristics e With four pivoting wheels e Capacity of 12 to 15 liters e Equipped with lid and handle e Made of stainless steel grade 304 or better or equivalent to AISI standard Electrical N A No aplican Characteristics Caracteristicas El ctricas ps e a ie Sa ei e Con cuatro ruedas giratorias haracteristics Capacity of 12 to 15 liters l Caracteristica Equipped with lid and handle e Con capacidad de 12 a 15 litros s Mec nicas e Made of stainless steel grade 304 or better or e Equipada con defensa y manija equivalent to AISI standard Fabricado en acero inoxidable grado 304 o mejor seg n norma AISI o equivalente Unidad de Proyectos MSPAS Page 72 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Technical Information Required Informaci n T cnica Requerida N A No aplica Warranty Garant a One 1 year manufacturer s defect warranty from Garant a contra desperfectos de fabricaci n de date of satisfactory delivery un a o a partir de la entrega de conformidad
24. made of Todo el instrumental debe ser de acero inoxidable grado 304 Characteristics stainless steel graded 304 or better o mejor Caracter sticas Unidad de Proyectos MSPAS Page 60 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Mec nicas Condiciones de Delivery in proper functioning order Deber entregarse de conformidad Instalaci n Technical Certificate of Quality Certificado de calidad Information Required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de un a o a Garant a warranty from date of satisfactory partir de la entrega de conformidad delivery Unidad de Proyectos MSPAS Page 61 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Minor Surgery Kit 25 7 Caja de pequena cirugia TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Equipment Minor Surgery Kit Caja de peque a cirug a Equipo Description Kit should consist of the following 4 pinzas campo de 15 cm Descripci n e 4 towel clamps 15 cm 1 Porta agujas curvo de 15 cm e 1 curved Needle Holder 15 cm 1 Porta agujas recto de 15 cm e 1 straight Needle Holder 15 cm 2 Pinzas de disecci n con garra de 15 cm e 2 dissecting clamp 15 cm 2 P
25. menos dos de sus ruedas Superficie para colocar el equipo electrom dico con gabinete con gavetas para guardar insumos Conditions of Reception Condicionesde Recepci n Device should be delivered in proper functioning order according to distribution matrix and area Director Deber entregarse a entera satisfacci n de la Jefatura del rea seg n matriz de distribuci n RequiredTechnical Information Informaci nT cnica Requerida Required Technical Information Operating Service and Parts Manual in Spanish or translated into Spanish Manual de Operaci n Manual de Servicio Manual de Partes En castellano o debidamente traducido al espa ol Warranty Garant a Warranty Three year warranty against faulty manufacture from date of satisfactory installation During this period supplier will provide quarterly service visits to perform preventive maintenance to be Garant a contra desperfectos de fabricaci n de dos a os a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del suministrante en existencia de repuestos para un per odo m nimo de cinco a os Deber realizarse un programa de visitas de mantenimiento preventivo trimestral durante el per odo de vigencia de la garant a coordinado por el departamento Unidad de Proyectos MSPAS Page 20 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 coor
26. nebulizer capacity Rango de tama o de part culas 0 5 5 micrones 0 25 ml min minimum Presi n de operaci n 10 20 PSI e Particle size 0 5 5 microns e Nebulizer operating pressure 10 20 PSI Condition of Device should be delivered fully Deber entregarse ensamblado y funcionando en las Unidades Reception assembled and in proper de Salud correspondiente a entera satisfacci n del m dico Condiciones de functioning order to the Director o de la persona que ste designare para tal efecto Instalaci n y corresponding Health Units to the Recepci n satisfaction of the Medical Director or the designated party Technical Operation Manual Manual de Operaci n Information Service Manual Manual de Servicio Required Parts Manual Manual de Partes Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect De un a o contra desperfectos de fabricaci n a partir de la Garant a warranty from date of satisfactory fecha de puesta en funcionamiento del equipo delivery Compromiso del suministrante en existencia de repuestos para un per odo m nimo de 5 a os Written commitment from the supplier to have spare parts in stock for a period of a minimum of five 5 years Unidad de Proyectos MSPAS Page 41 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON ENT Diagnostic Set 16 14
27. nicas Powercord length 2 meters minimum Conditions of Device should be delivered fully Deber entregarse armada y funcionando en las Reception Condiciones de Instalaci n assembled and in proper functioning order to the corresponding Health Units to the satisfaction of the Medical Director or the designated party Unidades de Salud correspondiente a entera satisfacci n del m dico Director o de la persona que ste designare para tal efecto Technical Information N A No aplica Required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de un Garant a warranty from date of satisfactory a o a partir de la fecha de puesta en delivery funcionamiento del equipo Unidad de Proyectos MSPAS Page 30 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGL N Laryngoscope Adult 11 3 Laringoscopio para adulto TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Secretaria de Inclusion Social SIS San Rafael Cedros Carretera llobasco Km 451 2 Equipment Laryngoscope Adult Laringoscopio para adulto Equipo Location Bodega de Division de Asistencia Ubicaci n Alimentaria Description Descripci n Portable laryngoscope for use on adult patients rust resistant no parts of the dev
28. parts in stock for a period of a minimum repuestos para un per odo m nimo de 5 a os of five 5 years Unidad de Proyectos MSPAS Page 47 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGL N Mercurial Sohygmomanometer Pedestal Type 19 7 Tensi metro de mercurio tipo pedestal con manga adulto pediatrica y neonatal TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Equipment Mercurial Sohygmomanometer Tensi metro de mercurio de tipo pedestal Equipo Pedestal Type Description Mercurial sohygmomanometer Tensi metro de mercurio escala de 0 300 mmHg 1 Descripci n nanometers 0 300 mmHg 1 mmHg mmHg Pedestal type Tipo pedestal Incluye manga con cierre por banda Includes velcro cuff pressure control velcro control de presi n toque pluma que permita la with rubber bulb control valve smooth salida de aire de manera suave y uniforme Para uso en and uniform air release brazo de adulto con el m todo auscultatorio Accesorios For use in adults 1 manga de hule para adulto 1 manga de hule pedi trica para pre escolares ni os 2 4 Accessories a os Rubber cuffs as follows 1 manga de hule pedi trica para escolares ni os de 4 a 1 for adult 7 a os 1 pediatric 2 4 years old 1 manga de hule neonatal 1 pediatric 4 7 years old 1 pera de hule con v lvu
29. persona que ste Recepci n designated party designare para tal efecto Unidad de Proyectos MSPAS Page 14 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Written commitment from the supplier to have spare parts in stock for a period of a minimum of three 3 years Technical Operation Manual Manual de operaci n Information Maitenance Service Manuals Manual de servicio Required Informa ci n T cnica Requerida Warranty One 1 year manufacturer s defect warranty from Garant a contra desperfectos de fabricaci n de Garant a date of satisfactory delivery un a o a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del suministrante en existencia de repuestos para un per odo m nimo de tres a os Unidad de Proyectos MSPAS Page 15 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Defibrillator 6 1 Desfibrilador TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS synchronous or asynchronous electric current for the purpose of regulating heart beats as well as heart rate surveillance Defibrillator with ECG monitor sensor with external paddles energy of defibrillation 1 360 Joules language of operation language on diplay screen in Spanish 3 electrode ECG cab
30. que ste designare para tal efecto Recepci n satisfaction of the Medical Director or the designated party Unidad de Proyectos MSPAS Page 12 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Technical Information Required Informacion T cnica Requerida Operation Manual Manual de operaci n Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Written commitment from the supplier to have spare parts in stock for a period of a minimum of three 3 years Garant a contra desperfectos de fabricaci n de un a o a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del suministrante en existencia de repuestos para un per odo m nimo de tres a os Unidad de Proyectos MSPAS Page 13 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Detector Ultrasonico de Latido Fetal ITEM NUMB ER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Fetal Ultrasound 5 7 TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Characterisitcs Caracteristicas sets Battery charger with battery life indicator included Equipment Fetal Ultrasound Detector Ultras nico de Latido Fetal Equipo Description Ultrasound for use in general consultation of Detector fetal para uso en consulta general de Descripci n gyne
31. siguientes e Control de selecci n de energ a e Control de carga e Indicador de nivel de energ a e Indicador de carga e Control de carga descarga de la bater a e Indicador de sincronizaci n Con paletas de los siguientes tipos e Paletas externas reusables que detecten actividad electrocardiogr fica convertibles para adulto y para ni o e Paletas externas para adulto superficie 82 cm aproximadamente e Paletas externas pedi trica superficie 17 cm aproximadamente Todas estas paletas deber n ser de tipo autoclavables Accesorios adicionales 1 Juego de cable de electrodo ECG reusable 12 Tubos de gel conductivo 12 Rollos de papel t rmico Maleta y carro de transporte El equipo debe estar construido de acuerdo a normas de seguridad y est ndares para servicios hospitalarios cr ticos Adem s deber cumplir con normas de Unidad de Proyectos MSPAS Page 17 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 channel construcci n reconocidas internacionalmente tales como UL ASTM NEMA ISO IEC VDE JIS ANSI AAMI DIN o similares It should contain the Que cumpla con la norma AAMI DF2 1982 o versi n following indicators actualizada a Energy selection control b Charge control c Energy level indicator d Charge indicator e Charge control discharge of the battery f Synchronization indicator With the following types
32. superior closing mechanism All equipment should adhere to internationally recognized manufacturing standards such as UL AAMI ANSI ASTM ISO or similar Como minimo debe incluir Hoja curva Macintosh No 3 y No 4 Hoja recta Miller No 2 No 3 y No 4 Estuche e Compacto e Facil de limpiar e Con compartimientos interiores para mantener los instrumentos en posici n e Con cierre de cremallera o sistema mejorado El equipo debe cumplir con normas de construcci n reconocidas internacionalmente tales como UL AAMI ANSI ASTM ISO o similares Electrical Characteristics Caracter sticas El ctricas Powered by rechargeable batteries Charger should also be included Funcionamiento a base de bater as recargables Incluye sistema de carga de bater as Mechanical Characterstics Caracter sticas Mec nicas Constructed of 304 grade stainless steel or better The unit should be well manufactured with resistant and durable material that permits the use and cleaning of all the parts of the equipment Construido de acero inoxidable grado 304 o mejor La unidad deber estar bien construida con material resistente y durable que permita el uso y limpieza t pica de todas las partes del equipo Conditions of Reception Condiciones de Recepci n Device should be delivered fully assembled and in proper functioning order to the corresponding Health Units to the satisfaction of the Medic
33. to the corresponding correspondiente a entera satisfacci n del m dico Condiciones de Health Units to the satisfaction of the Director o de la persona que ste designare para tal Recepci n Medical Director or the designated party efecto Unidad de Proyectos MSPAS Page 25 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Technical Operation Manual Manual de operaci n Information Required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de un a o Garant a warranty from date of satisfactory delivery a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del suministrante en Written commitment from the supplier to existencia de repuestos para un per odo m nimo de have spare parts in stock for a period of a tres a os minimum of three 3 years Unidad de Proyectos MSPAS Page 26 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGL N Stethoscope Pediatric Child 9 9 Estetoscopio Pediatrico TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Characterisitcs Caracteristicas Equipment Stethoscope Pediatric dual bell Estetoscopio Biauricular infantil de doble campana Equipo Description Biauricular stet
34. CHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Stethoscope Adult 21 Estetoscopio adulto TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Equipment Double Head Stethoscope Adult Estetoscopio Biauricular para adulto de doble campana Equipo Description Biauricular stethoscope doube head with Estetoscopio biauricular para adulto de doble Descripci n combination of bronze bell and flat campana con combinaci n de campana de bronce y diaphragm in order to detect a broad diafragma liso para detectar una amplia gama de range of sound frequencies frecuencias de sonido Two in one tube design Dise o de dos tubos en uno Complete with accessories Include 3 flat Completo con sus accesorios replacement spare diaphragms Incluir 3 diafragmas lisos de repuesto Electrical N A No aplican Characteristics Caracteristicas El ctricas Mechanical Chrome plated bronze bell Fabricado con campana de bronce cromada Characteristics Tubing manufactured from PVC or other Tubo fabricado en PVC u otro material resistente de Caracteristicas resistant material in one single piece for una pieza para mejor audici n Mec nicas better auditory properties Libre de l tex Latex free De alta durabilidad FDA and EC certified Certificado con FDA y CE Conditions of Device should be delivered in proper Deber entregarse en las Unidades de Salud Reception functioning order
35. Caracter sticas El ctricas Mechanical Made of stainless steel graded Fabricado en acero inoxidable grado 304 o mejor seg n Characteristics 304 or better according to AISI norma AISI o equivalente Caracter sticas standard or equivalent Mec nicas Installation Must be delivered in working Deber entregarse de conformidad Condition order Condiciones de Instalaci n Unidad de Proyectos MSPAS Page 89 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Technical N A No aplica Information Required Informaci n T cnica Requerida Warranty Garantia One 1 year manufacturers Garant a contra desperfectos de fabricaci n de un a o a defect warranty from date of partir de la entrega de conformidad satisfactory delivery Unidad de Proyectos MSPAS Page 90 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Wheelchair 41 6 Silla de ruedas TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Article Articulo Wheelchair Silla de ruedas tipo manual para traslado de paciente adulto Description and Mechanical Characteristics Descripci n y Caracter sticas Mec nicas Folding wheelchair to move adult patients within hospital e Rugged durable construction folding type e Desk type removable armrests
36. ECIFICACIONES TECNICAS Type Graves Size Small Approximate dimensions 75 x 20 mm Equipment Equipo Graves Vaginal Speculum Small Esp culo vaginal peque o Description Material Stainless Steel grade Material Acero inoxidable Descripci n 304 or better Dimensiones aproximadas 75 X 20 mm Electrical Characteristics Caracter sticas El ctricas N A No aplican Mechanical Characteristics Caracter sticas Mec nicas All instruments must be made of stainless steel grade 304 or better Todo el instrumental debe ser de acero inoxidable grado 304 o mejor Installation Conditions Condiciones de Instalaci n Delivery in proper functioning order Deber entregarse de conformidad Technical Information Required Informaci n T cnica Requerida Certificate of Quality Certificado de calidad Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de un a o a partir de la entrega de conformidad Unidad de Proyectos MSPAS Page 69 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER RENGLON DESCRIPTION DESCRIPCION QUANTITY CANTIDAD 30 Graves Vaginal Speculum Virginal Esp culo vaginal tipo Grave virginal 35 TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Equipment Equipo
37. ECIFICATIONS AUGUST 2011 Condiciones de assembled and in proper functioning Salud correspondiente a entera satisfacci n del Recepci n order to the corresponding Health m dico Director o de la persona que ste designare Units to the satisfaction of the para tal efecto Medical Director or the designated party Technical Information Operation Manual Manual de Operaci n Required Parts Manual Manual de Partes Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect De un a o contra desperfectos de fabricaci n a partir Garant a warranty from date of satisfactory de la fecha de puesta en funcionamiento del equipo delivery Compromiso del suministrante en existencia de Written commitment from the supplier repuestos para un per odo m nimo de 5 a os to have spare parts in stock for a period of a minimum of five 5 years Unidad de Proyectos MSPAS Page 53 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Manual Resuscitation Set Neonatal 22 7 Set de resucitador manual neonatal TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Characteristics Caracteristicas Equipment Manual Resuscitation Set Neonatal Set de resucitador manual neonatal Equipo Description Manual resuscitation set for use with Resucitador para ventilaci n manual de pa
38. Gabinete met lico que soporta el equipo y con compartimientos para equipos perif ricos estabilizador de voltaje impresor etc m vil con rodos para f cil desplazamiento y sistema de frenos mec nico Transductores Transductores multifrecuencia es decir con capacidad para funcionar a m ltiples frecuencias rango 2 5 a 12 MHz se requieren los siguientes 1 Transductor endovaginal 1 Transductor para partes peque as DE 7 5 12 MHz 1 Transductor lineal para aplicaciones generales 1 Transductor convexo 1Transductor lineal para aplicaciones generales Unidad de Proyectos MSPAS Page 3 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Accessories Covers for equipment and its periperal parts Thermal printer black and white Stabilizer voltage regulator and UPS for equipment and peripherals Fifty 50 rolls of paper for printer Type V 30 tubes of conductive hydrosoluble gel for ultrasound hydrosoluble y de mamografia Accesorios Fundas protectoras para el equipo y sus perif ricos Impresor t rmico blanco y negro Estabilizador regulador de voltaje y UPS para el equipo y sus perif ricos 50 rollos de papel para impresor tipo V 50 rollos 30 tubos de gelatina conductiva para ultrasonido hidrosoluble Polarized outlet hospital grade Type of electrical safety BF according to IEC 60601 1 or UNE 20613 norms UPS with voltage stabil
39. MEDICAL EQUIPMENT EQUIPO MEDICO ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER RENGLON DESCRIPTION DESCRIPCION QUANTITY CANTIDAD Portable Ultrasound Machine Equipo de Ultrasonido portatil TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS obstetrics in pregnancy and childbirth urology and general abdomen use Modes of operation Mode B 2D Mode M Mode C Mode B M Real time analysis Monitor minimum 9 inch Minimum Resolution adjustable grey scale 256 shades of grey Imaging Format One single picture Equipment Portable Ultrasound Machine Equipo de Ultrasonido port til Equipo Descrition Portable high resolution ultrasound for use in Equipo de ultrasonido port til de alta resoluci n Descripcion general consultation of gynecology and para diagn stico en m ltiples especialidades Ginecologia y Obstetricia Urologia y Abdominal General Modos de operaci n Modo B 2D Modo M Modo C Modo B M An lisis de tiempo real Monitor 9 pulgadas m nimo Resoluci n m nima escala de grises ajustables 256 tonos de gris Formato de imagen Una sola imagen Unidad de Proyectos MSPAS Page 2 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Double picture Still Picture Control Panel Alphanumeric Spanish keyboard Trackball mouse Illuminated
40. NICAL SPECIFICATIONS AUGUST 2011 delivery Written commitment from the supplier to have spare parts in stock for a period of a minimum of five 5 years Technical Operation Manual Manual de Operaci n Information Parts Manual Manual de Partes required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect De un a o contra desperfectos de fabricaci n a partir de la Garant a warranty from date of satisfactory fecha de puesta en funcionamiento del equipo Compromiso del suministrante en existencia de repuestos para un per odo m nimo de 5 a os Unidad de Proyectos MSPAS Page 55 of 94 LABORATORY EQUIPMENT EQUIPO DE LABORATORIO CL NICO ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Refrigerator Laboratory Use 23 7 Refrigerador para Laboratorio TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Equipment Refrigerator Laboratory Use Refrigerador para laboratorio Equipo Descri ption Dry cooling electric operation with Con enfriamiento a frio seco con funcionamiento Descripci n approximately 10 to 15 cubic feet in el ctrico con capacidad aproximada de 10 a 15 pies capacity two doors with magnetic c bicos de dos puertas con cierre herm tico tipo hermetic seal with integrated magn tico integrado con control termost ti
41. ONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 INSTRUMENTAL Unidad de Proyectos MSPAS Page 59 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON First Aid Kit 24 10 Caja de curaciones TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Equipment First Aid Kit Caja de curaciones Equipo Description Metallic box containing Caja metalica conteniendo Descripci n e 1 Foerster clamp with round 1 Pinza de anillos de 30 cm eyelet 30 cm 2 Tijera Mayo curva de 17 cm e 2 Curved Mayo Scissors 17 cm 10 Pinzas Allis grandes de 15cm e 10 Large Allis tweezers 15 cm 6 Copas o escudillas de 6 onzas e 6 Stainless steel cups of 6 ounces 2 Pinza de disecci n de 15 cm con garra e 2 dissecting clamps 15 cm with Incluye adem s fuera de la caja l claw 1 Bandeja para colocar instrumental medidas 45 cm de i largo x 30 cm de ancho por 2 cm de alto g Aaa lis 10 Dep sitos redondos para guardar torundas medidas 15 o 1 Tray to place instruments cm de di metro x 18 cm de alto completamente met licos Size 45 cm L x 30 cm W by tapa y cuerpo 2 cm H o 10 round containers to keep swabs Size 15 cm diameter x 18 cm H completely made of metal body and top Electrical N A No aplican Characteristics Caracter sticas El ctricas Mechanical All instruments should be
42. Unidad de Proyectos MSPAS Page 73 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Patient Stretcher Trolley 32 1 Carro Camilla de transporte TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Article Articulo Patient Stretcher Trolley with Safety Rails Camilla de transporte de paciente con barandales Description and e Patient transfer trolley Mechanical e Round tubular stainless steel construction e Carro para traslado de pacientes Characteristics e With tubular stainless steel hinged and CharaDescripci n retractable safety rails e Construcci n tubular redonda en acero y e Weight capacity 300 pounds inoxidable Caracter sticas e Polyurethane foam mattress minimum 2 Mecanicas wrapped in strong plastic cover washable e Con barandales de seguridad tubulares de highly resistant to disinfecting liquids acero inoxidable abatibles y retr ctiles e With two hooks or poles to hold solutions dee Head area e C idad de soportar 300 libras de peso e Wheels 4 in diameter minimum Sr re P crores RUDDER WEN DraKes On te e Colchoneta de espuma de poliuretano de 2 e High impact bumpers and shock protection eee TTS cubierta de plastico fuerte around the perimeter lavable altamente resistente a l quidos de e Approximate dimensions desinfecci n e Height 0 80 m e Length 1 95 m e Con a
43. al Director or the designated party Deber entregarse a entera satisfacci n de la Jefatura del rea asignada seg n matriz de distribuci n Unidad de Proyectos MSPAS Page 32 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Technical Information Required Informaci n T cnica Requerida Operation Manual Parts Manual Manual de operaci n Manual de partes Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Written commitment from the supplier to have spare parts in stock for a period of a minimum of five 5 years Garant a contra desperfectos de fabricaci n de un a o a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del suministrante en existencia de repuestos para un per odo m nimo de cinco a os Unidad de Proyectos MSPAS Page 33 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Laryngoscope Pedriatric Child 12 3 Laringoscopio pediatrico TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS school and school aged 2 to 10 years old rust resistant no parts of the device should have sharp edges The device will be provided complete with its handle lamps case and sheets Handle Striated external met
44. allic handle provided with batteries Capable of attaching both straight and curved blades for use with pediatric patients 2 to 10 years old Lamp White halogen light for a uniform illumination Includes a replacement bulb If the blades require different bulbs include a bulb per each type Equipment Laryngoscope Pediatric Laringoscopio pedi trico Equipo Description Portable laryngoscope for use Laringoscopio port til para aplicaci n en pacientes Descripci n on peditatric patients pre pedi tricos pre escolares y escolares 2 a 10 a os resistente a la corrosi n ninguna parte del equipo deber presentar bordes con filo El equipo se suministrar completo con su mango l mparas estuche y hojas Mango Mango met lico externo estriado provisto de bater as Capacidad de acople de hojas rectas y curvas para aplicaci n en pacientes pedi tricos de 2 a 10 a os L mpara L mpara hal gena luz blanca para una iluminaci n uniforme Incluir un bombillo de repuesto Si las hojas necesitan diferente bombillo incluir un bombillo por cada tipo Hojas Hojas para aplicaci n en pacientes pedi tricos de 2 a 10 a os fabricadas en acero inoxidable Como m nimo debe incluir Hoja curva Macintosh No 2 y No 3 Hoja recta Miller No 1 y No 2 Estuche Unidad de Proyectos MSPAS Page 34 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011
45. avable plastic washable brown color Dimensiones aproximadas upholstery Ancho de silla 50 cm Approximate dimensions Profundidad de la silla 45 cm Unidad de Proyectos MSPAS Page 93 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 e Chair Width 50 cm e Chair depth 45 cm e Back 50 X 35cm e Drawers 19 cm X 43 cm Respaldo 50 X 35 cm Cajones 19 cm X 43 cm delivery Technical Information N A No aplica Required Informaci n T cnica Requerida Warranty One 1 year manufacturers defect Garant a contra desperfectos de fabricaci n de un a o a partir Garant a warranty from date of satisfactory de la entrega de conformidad Unidad de Proyectos MSPAS Page 94 of 94
46. ay Con un arillo porta cubeta que incluya la cubeta y porta characteristics and basin holder made of 10 palangana de placa de acero calibre 10 de 25 4 cms 1 Caracteristicas gauge steel sheet metal of 25 4 de ancho acabado cromado que incluya bandeja Mecanicas mm 1 wide chrome plated Cubiertas de lamina de acero inoxidable calibre 18 finish must include tray acabado pulido e Covered in 18 gauge stainless Entrepa o de lamina de acero inoxidable calibre 18 steel plating polished finish acabado pulido e Shelf made of 18 gauge stainless Estructura de perfil tubular de acero calibre 18 de 25 4 cm steel polished finish de di metro acabado cromado Unidad de Proyectos MSPAS Page 78 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 e Structure made of 18 gauge steel with 25 4 mm 1 diameter chrome finish e Cover made of 18 gauge stainless steel polished finish e Solid commercial type castors made with natural or synthetic rubber 10 16 cm 4 in diameter color black Approximate dimensions e Length 80 cm e Width 40 cm e Height 70 cm Made of stainless steel graded 304 according to AISI standards or equivalent Note General dimensional tolerances 1 00 cm Must include following accessories One 1 clamp holder including round eyelet clamp 15 cm 3 stainless steel drums for swabs and gauze 3 glass drums 2 large and 1 sma
47. calera met lica de dos pelda os Descripci n Electrical N A No aplican Characteristics Caracter sticas El ctricas Mechanical e Made of chromed iron tubes Material ser tubo de hierro cromado Characteristics e Round cross section of 1 2 Secci n transversal redonda de Y de dos Caracter sticas e Two rungs steps covered with escalones con cubierta de tapiz ahulado Mec nicas rubberized Las patas llevar n zapatillas de hule material antideslizante e Legs will have no slip rubber caps Dimensiones aproximadas Approximate dimensions Alto 44 cm e Height 44 cm Ancho 37 cm e Width 37 cm Largo 41 cm Length 41 cm Required Technical N A No aplica Information Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de un warranty from date of satisfactory a o a partir de la entrega de conformidad delivery Unidad de Proyectos MSPAS Page 83 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Step Ladder 37 7 Gradilla de tres peldanos TECHNICAL SPECIFICATIONS ESPECIFIC ACIONES T CNICAS Article Articulo Step Ladder Gradilla de tres pelda os Description Metal step ladder with three rungs Escalera met lica de tres pelda os Descripci n Electrical N A No aplican Chara
48. ci n T cnica Requerida N A No aplica Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de un a o a partir de la entrega de conformidad Unidad de Proyectos MSPAS Page 80 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Cabinet for Samples 35 7 Gabinete para recepcion de muestras TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS steel 16 gauge with support polished finish e Metal 20 gauge door gray paint finish e Aluminum ferrules 25 mm 1 in diameter adjustable height e 18 gauge steel tubes 32 x 32 mm 1 x 1 Y gray paint finish Approximate Dimensions e Length 70 cm e Width 40 cm e Height 90 cm Made of stainless steel grade 304 Article Articulo Cabinet for Samples Gabinete para recepci n de muestras Description Movable cabinet to place Mesa rodable para colocar muestras de laboratorio Descripci n laboratory samples Electrical N A No aplican Characteristics Caracter sticas El ctricas Mechanical e Stainless steel 20 gauge 1 Caj n de lamina de acero inoxidable cal 20 con Characteristics drawer with integrated handle haladera integrada acabado en pintura color gris Caracter sticas gray paint finish 2 C
49. cientes para uso Descripci n ambient air as well as oxygen de aire ambiente y atm sfera enriquecida de ox geno en enriched air up to 95 concentraci n hasta 95 El equipo ser seguro y preciso concentration con su mascarilla y v lvula a prueba de golpes Adem s Set should be safe and precise ser suministrado con v lvula de alivio y presi n con The set should contain mascarilla para neonato e resuscitator bag e mask neonatal size e shock proof valve e pressure release valve Electrical N A No aplican Medical Director or the designated party El ctricas Mechanical Reusable with expandable Reusable con acumulador expandible con conector Characteristics accumulator with connection for externo para fuente de oxigeno fabricado en material Caracter sticas external oxygen source esterilizable de preferencia silic n Mec nicas Entry connector Hose for connecting Conector de entrada Manguera para conectar NPT de 1 4 to NPT of Ya Conditions of Device should be delivered fully Deber entregarse funcionando en las Unidades de Salud Reception assembled and in proper functioning correspondiente a entera satisfacci n del m dico Director o Condiciones de order to the corresponding Health de la persona que ste designare para tal efecto Recepci n Units to the satisfaction of the Unidad de Proyectos MSPAS Page 54 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECH
50. co de thermostatic temperature control and temperatura e iluminaci n interior interior illumination Electrical e Voltage 120 V Voltaje 120 VAC Characteristics e Frequency 60 Hz Frecuencia 60 Hertz Caracteristicas e Phases 1 Fases 1 El ctricas e Polarized male outlet Tomacorriente macho polarizado Mechanical Outer made of baked enamel laminate Mueble fabricado en lamina porcelanizada con Characteristics with isolated fiberglass or aislamiento de lana de fibra de vidrio o poliuretano Caracter sticas polyurethene Mec nicas Included Thermometer incorporated in door Term metro incorporado en la puerta Accessories external readout Accesorios incluidos Unidad de Proyectos MSPAS Page 57 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Technical Operation Manual Manual de Operaci n information Service Manual Manual de Servicio Received Informaci n T cnica Requerida Warranty Two 2 year manufacturer s defect Dos a os contra desperfectos de fabricaci n a partir de la Garant a warranty from date of satisfactory fecha de puesta en funcionamiento del equipo delivery Compromiso del suministrante en existencia de repuestos Written commitment from the supplierto para un per odo m nimo de 5 a os have spare parts in stock for a period of a minimum of five 5 years Unidad de Proyectos MSPAS Page 58 of 94 ESPECIFICACI
51. cology and obstetrics in pregnancy and ginecolog a y obstetricia en embarazo y labor de childbirth parto For detection of fetal heart beat transducer with a Para detecci n de latido fetal con transductor con range of 2 3 MHz with high definition and un rango de 2 3 MHz con pantalla LCD con alta illumination LCD screen that shows average fetal definici n e iluminaci n que muestra el promedio heart rate de la frecuencia card aca fetal Incluye parlante y Speaker and headphones included aud fonos Alarm when abnormal heart rate is detected Con alarma que indique cuando el ritmo card aco del feto est fuera de lo normal Electric Work voltage VDC with rechargeable batteries 2 Voltaje de trabajo VDC con bater as recargables 2 juegos Incluye cargador de baterias El ctricas Electric safety BF Con indicador del estado de las baterias Tipo de seguridad el ctrica BF Mechanical Portable small lightweight made of one single Port til peque o ligero fabricado en una sola Characteristic unit long life resitant pieza resistente Caracter sticas FDA and EC approved Aprobado por FDA y CE Mec nicas Conditions of Device should be delivered in proper functioning Deber entregarse funcionando en las Unidades Reception order to the corresponding Health Units to the de Salud correspondiente a entera satisfacci n Condiciones de satisfaction of the Medical Director or the del m dico Director o de la
52. cteristics C aracter sticas El ctricas Mechanical e Made of chromed iron tubes Material sera tubo de hierro cromado Characteristics C e Round cross section of Y Secci n transversal redonda de de tres escalones con aracter sticas e Three rungs steps covered with cubierta de tapiz ahulado Mecanicas rubberized material Las patas llevar n zapatillas de hule antideslizante e Legs will have no slip rubber caps Dimensiones aproximadas Approximate dimensions Alto 66 cm e Height 66 cm Ancho 37 cm e Width 37 cm Largo 41 cm e Length 41 cm Technical N A No aplica Information Required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de un a o a Garant a warranty from date of satisfactory partir de la entrega de conformidad delivery Unidad de Proyectos MSPAS Page 84 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER RENGLON DESCRIPTION DESCRIPCION QUANTITY CANTIDAD 38 Auxiliary Table for Instrument and Mesa auxiliar para instrumental y equipo Equipment 42 TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Article Articulo Auxiliary Table for Instrument and Equipment Mesa auxiliar para instrumental y equipo Description Descripci n Table used in the resident rest area to place instruments and equipment Lar
53. dinated by the Hospital s de mantenimiento del Hospital maintenance department Commitment from the supplier to have spare parts in stock for a period of 5 years 55 Unidad de Proyectos MSPAS Page 21 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Electric Sterilizer with Cabinet 7 3 Esterilizador el ctrico TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS chamber via a reservoir tank Low water protection e With manual controls for the sterilization cycle Temperature control water filling control steam evacuation control sterilization time control e Power indicator lights and sterilization process indicator lights e Audible alarm indicating the end of the sterilization process e Separate indicators gauges to monitor pressure and the temperature parameters of sterilization e Safety device to prevent opening the door when the chamber is pressurized e Safety valve which releases the pressure if chamber pressure exceeds a preset value of approximately 34 PSI e Includes three trays of 304 grade stainless steel for placement of surgical instruments Equipment Electric Sterilizer with Cabinet Equipo Esterilizador el ctrico de gabinete Description e Cabinet Sterilizer with its own electric Caracter sticas Descripci n steam generator gravity fill
54. dor manual adulto Equipo Description Manual resuscitation set for use with Resucitador para ventilaci n manual de pacientes Descripci n ambient air as well as oxygen para uso de aire ambiente y atm sfera enriquecida enriched air up to 95 de ox geno en concentraci n hasta 95 El equipo concentration ser seguro y preciso con su mascarilla y v lvula a The set should be safe and precise prueba de golpes Adem s ser suministrado con and should contain v lvula de alivio y presi n con mascarillas para e resuscitator bag adulto grande y mediana e masks large and medium size e shock proof valve e pressure release valve Electrical N A No aplican Characteristoics Caracteristicas El ctricas Mechanical Reusable with expandable Reusable con acumulador expandible con conector Characteristics accumulator with connection for externo para fuente de oxigeno fabricado en Caracteristicas external oxygen source Entry material esterilizable de preferencia silic n Mec nicas connector Hose for connecting to Conector de entrada Manguera para conectar NPT NPT of Y de 1 4 Items should be made of materials easily sterilized preferably silicone large and medium size masks for adults Conditions of Reception Device should be delivered fully Deber entregarse funcionando en las Unidades de Unidad de Proyectos MSPAS Page 52 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SP
55. e Reception Conditions Condiciones de Recepci n Device should be delivered in proper functioning order to the corresponding Health Units to the satisfaction of the Medical Director or the designated party Deber entregarse funcionando y calibrada en las Unidades de Salud correspondiente a entera satisfacci n del m dico Director o de la persona que ste designare para tal efecto Technical Information Required Informaci n T cnica Requerida Operation Manual Manual de operaci n Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Written commitment from the supplier to have spare parts in stock for a period of a minimum of three 3 years Garant a contra desperfectos de fabricaci n de un a o a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del suministrante en existencia de repuestos para un per odo m nimo de tres a os Unidad de Proyectos MSPAS Page 10 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Bascula para reci n nacido con infant metro ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGL N Scale with Height Rod Newborn 4 Measurement 7 TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS With measuring rod for measurement of newborn and lactating children Sliding measuring mechanism w
56. e Handles for pushing built into the structure e Rear wheel brake lever e Folding footrest height adjustable e Flexible seat and back to accommodate different patients e Telescopic IV pole incorporated in chair e Front wheels swivel solid anti dust e Rear wheels lateral fixed solid hand brake lever e Rear wheels with pushrim handrim e Weight capacity 250 pounds e Easy to clean metal structure anti rust and resistant to hospital grade disinfectants e Nylon or mildew resistant material upholstery and flame retardant e Polished aluminum foot rests e Rubber lined push handles e Padded armrests Approximate dimensions of the seat Silla de ruedas plegable para trasladar pacientes adultos que asi lo requieran dentro del hospital e De construcci n robusta y del tipo plegable e Descansa brazos tipo escritorio desmontable e Pu os de empuje incorporados a la estructura e Con palanca de freno para las ruedas traseras e Descansa pies abatibles con opci n para ajustar la altura e Asiento y respaldo flexible y adaptable a diferentes pacientes e Con atril porta suero tipo telesc pico incorporado a la silla e Ruedas antipelusa e Ruedas traseras fijas laterales macizas freno de palanca de mano delanteras giratorias macizas Unidad de Proyectos MSPAS Page 91 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 e 20 inches wide e 18
57. ed e Esterilizador de Gabinete con su propio generador el ctrico de vapor con llenado de c mara por gravedad desde un tanque reservorio Con protecci n de bajo nivel de agua Con controles manuales para el ciclo de esterilizaci n Control de temperatura Control de llenado de agua y evacuado de vapor hacia tanque reservorio de agua Y Control de tiempo de esterilizaci n L mparas indicadoras de encendido y del proceso de esterilizaci n Alarma sonora al final del proceso de esterilizaci n Medidores separados para monitorear los par metros de presi n y temperatura de esterilizaci n Dispositivo de seguridad para evitar la apertura de la puerta cuando la c mara est presurizada Con v lvula de seguridad para evacuar la presi n de c mara al sobrepasar un valor prefijado de 34 PSI aproximadamente Incluye 3 charolas de acero inoxidable grado 304 para colocaci n de instrumental quir rgico Unidad de Proyectos MSPAS Page 22 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 e For use in sterilization area Included Accessories Stainless steel Instrument holder tray e Para uso en area de esterilizaci n Accesorios incluidos Instrumento porta charola de acero inoxidable With the following minimum requirements Chamber Capacity 60 75 liters approx Approximate Chamber Dimensions 380mm diameter x 660mm length Temperature range 115 C
58. eg n recomendaciones del fabricante informaci n provided to the UACI upon notification of que se har llegar a la UACI inmediatamente award despu s de recibir la notificaci n de adjudicaci n Vendor will install and test the operation of El suministrante instalar y probar el equipment supplying all the necessary funcionamiento del equipo llevando todos los materials for this purpose Delivered in proper insumos necesarios para tal efecto functioning order to the corresponding Health Se entregar a entera satisfacci n del m dico Units to the satisfaction of the Medical Director o de la persona que ste designare para tal Director or the designated person efecto Technical Installation Manual Manual de Instalaci n Information Operation Manual Manual de Operaci n Required Maintenance Service Manual Manual de Servicio Informaci n Parts Manual Manual de Partes T cnica Requerida Warranty Three 3 year manufacturer s defect warranty Garant a contra desperfectos de fabricaci n de tres Garant a from date of satisfactory delivery a os a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del Written commitment from the supplier to have suministrante en existencia de repuestos para un spare parts in stock for a period of a minimum per odo m nimo de cinco a os of five 5 years Unidad de Proyectos MSPAS Page 24 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TE
59. el Director del establecimiento de salud designe Deber realizar cuatro rutinas de mantenimiento preventivo por a o durante el periodo de la garant a presentar programa de Unidad de Proyectos MSPAS Page 4 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 carried out yearly during warranty period present program of technical calls visits Written commitment from the supplier to have spare parts in stock for a period of 5 years minimum Supplier will provide training to operating and technical maintenance personnel including Operation cleaning and handling of device preventive maintenance a most frequent issues that arise with device s use Technical Support The supplier must have local Biomedical Technical Department with personnel trained by the manufacturer Supplier must guarantee that it has qualified personnel for preventive maintenance according to required schedule visitas t cnicas Compromiso por escrito del suministrante en proveer repuestos para un per odo m nimo de 5 a os Capacitaci n El suministrante proporcionar la capacitaci n y comprender La operaci n limpieza y manejo del equipo mantenimiento preventivo y fallas m s frecuentes del equipo Impartidas al personal operador y t cnico de mantenimiento respectivamente Soporte T cnico La empresa suministrante deber contar localmente con Departamento T cnico B
60. el suministrante en existencia de repuestos para un per odo m nimo de 5 a os Unidad de Proyectos MSPAS Page 45 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Aneroid Sphygmomanometer Pediatric 18 2l Tensi metro Aneroide Pedi trico TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Equipment Aneroid sphygmomanometer Pediatric Tensi metro aneroide para ni os y lactantes Equipo Description Hand aneroid sohygmomanometer Tensi metro aneroide de mano escala de 0 300 Descripci n nanometers 0 300 mm of Hg calibration mmHg 3 mmHg port til con cierre de manga por 3mm Hg portable with adult velcro cuff medio de banda velcro control de presi n toque pressure control with rubber bulb control pluma que permita la salida de aire de manera valve smooth and uniform air release suave y uniforme Para uso en brazo de ni o y lactantes For use on child and lactating child s arm Incluir estuche de cuero con cierre de alta durabilidad para ser utilizado con el m todo Complete in portable packable leather box auscultatorio Accesorios Must include following accessories Una manga de hule pedi trica pre escolares ni os de 2 4 a os Pediatric cuff sizes Una manga de hule pedi trica escolares ni os de 0 2 years 4 7 anos 2 4 years Una manga de hule para
61. ent halogen lights Electrical Working voltage 3 VDC Voltaje de trabajo 3VDC Unidad de Proyectos MSPAS Page 42 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Characteristics Two rechargeable C size Incluye 2 bater as de 1 5 VDC tama o C recargables Caracter sticas 1 5V batteries El ctricas Mechanical Chrome plated metallic handle Mango met lico cromado incluye accesorio para convertir el Characteristics with accessory for handle to mango a bater a recargable Caracter sticas function as battery recharger Vers til Mec nicas Versatile Resistente Resistant Conditions of Device should be delivered fully Deber entregarse funcionando en las Unidades de Salud Reception assembled and in proper correspondiente a entera satisfacci n del m dico Director o Condiciones de functioning order to the de la persona que ste designare para tal efecto Recepci n corresponding Health Units to the satisfaction of the Medical Director or the designated party Technical Information Required Informaci n T cnica Requerida Operation Manual Parts Manual Manual de Operaci n Manual de Partes Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Written commitment from the supplier to have spare parts in stock for a period of a minimum of five 5 years De un a o contra despe
62. escripci n an approximate capacity of 350 Ibs 160 kg height rod with an B scula de Pedestal plataforma s lida con capacidad PE re capacity of up to 1 95 aproximada de 350 Lbs 160 Kg con tallimetro de Weight should b measured In both hasta 1 95 metros aproximadamente La graduaci n de pounds and kilograms and height las escalas deber estar en libras y kilogramos para el should be measured in both peso y en centimetros y pulgadas para la talla La centimeters and inches resoluci n deber ser aproximadamente de 4 onzas 100 Weight graduation approximately 4 gramos para el peso y 1 cm para la talla ounces 100 grams Height graduation 1 cm Electrical N A No aplican Characteristics Caracter sticas El ctricas Mechanical e It should be done of resistant a Charateristics metal for heavy use e Deber estar hecha de metal resistente para uso Caracter sticas Easily transportable pesado Mecanicas e With system of counter weights De facil transporte Con sistema de contra pesos y o resortes e Con escalas de f cil lectura tanto para el peso como para la talla integrada al pedestal de la b scula met lica y con movimiento de la aguja indicadora por Unidad de Proyectos MSPAS Page 9 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 movement of the indicator needle by means of rail Oven painted washable medio de riel Pintada al horno lavabl
63. f 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Written commitment from the supplier to have spare parts in stock for a period of a minimum of three 3 years T cnica Requerida Warranty One 1 year manufacturer s defect warranty Garant a contra desperfectos de fabricaci n de un Garant a from date of satisfactory delivery a o a partir de la fecha de puesta en funcionamiento del equipo Compromiso escrito del suministrante en existencia de repuestos para un per odo m nimo de tres a os Unidad de Proyectos MSPAS Page 28 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Examination Lamp Goose Neck 10 14 Lampara para examen tipo cuello de ganso TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Secretaria de Inclusion Social SIS San Rafael Cedros Carretera llobasco Km 451 2 Equipment Metal Examination Lamp Goose Neck L mpara para examen tipo cuello de ganso Equipo met lica Location Bodega de Division de Asistencia Ubicaci n Alimentaria Description Descripci n Lamp with adjustable neck goose neck for examinations flexible swivel with reflective screen that increases the intensity and uniformity of the light on pedestal with adjustable height For use in physician s office Incl
64. ge table for various type work with castors and shelves Steel tube 18 gauge 32 X 32 mm 1 4 X 1 grey color finish Approximate Dimensions e Length 70 cm e Width 40 cm e Height 90 cm e Made in stainless steel 304 grade or better accrding to AISI standards or equivalent Mesa rodable auxiliar para colocar instrumental y equipo Mesa para trabajos diversos grande de acero inoxidable con rodos y entrepa os Tubo de acero cal 18 de 32x32mm 11 4 x 11 4 acabado de pintura color gris Dimensiones aproximadas 70cm de largo 40 cm de ancho y 90 cm de alto Fabricada en acero inoxidable grado 304 o mejor seg n norma AISI o equivalente Electrical N A N A Characteristics Caracter sticas El ctricas Mechanical Characteristics N A N A Caracter sticas Mec nicas Unidad de Proyectos MSPAS Page 85 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Technical Information Required N A N A Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturers defect warranty from date of Garant a contra desperfectos de satisfactory delivery fabricaci n de un a o a partir de la entrega de conformidad Unidad de Proyectos MSPAS Page 86 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON
65. hoscope doube head with Estetoscopio biauricular pedi trico de doble Descripci n combination of bronze bell and flat diaphragm campana con combinaci n de campana de in order to detect a broad range of sound bronce y diafragma liso para detectar una amplia frequencies gama de frecuencias de sonido Two in one tube design Dise o de dos tubos en uno Complete with accessories Include 3 flat Completo con sus accesorios replacement spare diaphragms Incluir 3 diafragmas lisos de repuesto Electrical N A No aplican El ctricas Mechanical Chrome plated bronze bell Fabricado con campana de bronce cromada Characteristics Tubing manufactured from PVC or other Tubo fabricado en PVC u otro material resistente Caracteristicas resistant material in one single piece for de una pieza para mejor audici n Mec nicas better auditory properties Libre de l tex Latex free De alta durabilidad FDA and EC certified Certificado con FDA y CE Conditions of Device should be delivered in proper Deber entregarse en las Unidades de Salud Reception functioning order to the corresponding Health correspondiente a entera satisfacci n del m dico Units to the satisfaction of the Medical Director o de la persona que ste designare para Condiciones de Director or the designated party tal efecto Recepci n Technical Operation Manual Manual de operaci n Information Required Informaci n Unidad de Proyectos MSPAS Page 27 o
66. ice should have sharp edges The device will be provided complete with its handle lamps case and sheets Handle Striated external metallic handle provided with batteries Capable of attaching both straight and curved blades Lamp White halogen light for a uniform illumination Includes a replacement bulb If the blades require different bulbs include a bulb per each type Blades Stainless Steel at the Laringoscopio port til para aplicaci n en paciente adulto resistente a la corrosi n ninguna parte del equipo deber presentar bordes con filo El equipo se suministrar completo con su mango l mparas estuche y hojas Mango Mango met lico externo estriado provisto de bater as Capacidad de acople de hojas rectas y curvas para aplicaci n en paciente adulto L mpara L mpara hal gena luz blanca para una iluminaci n uniforme Incluir un bombillo de repuesto Si las hojas necesitan diferente bombillo incluir un bombillo por cada tipo Hojas Hojas para aplicaci n en paciente adulto fabricadas en acero inoxidable Unidad de Proyectos MSPAS Page 31 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 very least it should include Curved blade Macintosh No 3 and No 4 Straight blade Miller No 2 No 3 and No 4 Case Compact Easy to clean With interior compartments to secure instruments in position With zipper or
67. inzas de disecci n sin garra de 15 cm e 2 dissecting clamp without claw 15 cm a eS patel AS ess a Foerster clamp with round eyelet 15 2 Sepaladores Farabeau de 10 m e 2 Stainless steel cups of 6 ounces 2 Pinzas Rochester curvas de 15 cm e 2 Farabeau Separators 10 cm 2 Pinzas Rochester rectas de 15 cm 2 Tweezers Rochester curved 15 on Pinzas HALSTED euras de Sm e 2 Tweezers Rochester straight 15 cm 3 Porta Torundas curvos de 18 cm e 4 Tweezers Halsted curved 15cm 4 Erinas de FRAZIER de 6 e 4 Tweezers Halsted straight 15 cm e 3 Swab holders curved 18 cm e 4 Frazier clamps of 6 Electrical N A No aplican Characteristics Caracteristicas El ctricas Mechanical All instruments should be of Stainless Steel Todo el instrumental debe ser de acero inoxidable Chararteristics graded 304 or better grado 304 o mejor Caracteristicas Mecanicas Unidad de Proyectos MSPAS Page 62 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Installation Conditions Condiciones Instalaci n de Delivery in proper functioning order Deber entregarse de conformidad Technical Information required Informaci n T cnica Requerida Certificate of Quality Certificado de calidad Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de un a o a part
68. iom dico con personal entrenado por el fabricante Deber garantizar que brindar el soporte t cnico con personal calificado para el mantenimiento preventivo de acuerdo al programa exigido Unidad de Proyectos MSPAS Page 5 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Neonatal Suction Pump 2 7 Aspirador de secreciones neonatales TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS pump capable of maintaining a flow of 5 liters minute e Suction control between 7 5 to 150 mm Hg 200mBar e Equipped with hydrophobic bacteriological filter in order to prevent contamination e 1000 ml bottle preferably glass or polycarbonate autoclavable printed with indelible measurements with system to stop reverse flow and safety device to avoid overflow It should also include pressure manometer e Low level of noise The device is to be manufactured in Equipment Neonatal Suction Pump Aspirador de secreciones neonatales Equipo Description Neonatal suction pump mobile Aspirador de secreciones para aplicaci n en pacientes Descripci n capable of continuous suction with neonatos m vil de succi n continua con bomba de membrana capaz de mantener un flujo de 5 litros minuto Control de succi n entre 7 5 a 150 mm Hg 200mBar Equipado con filtro bacteriol
69. ip rubber stoppers covering feet of the examination couch Reception Conditions Must be delivered in working Deber entregarse de conformidad Condiciones de order Instalaci n Technical Information N A No aplica Required Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de un a o a partir de la entrega de conformidad Unidad de Proyectos MSPAS Page 77 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Dressing Trolley 34 7 Carro para curaciones TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Article Art culo Dressing Trolley Carro para curaciones Description Movable trolley to place dressings Mesa rodable para colocar material para curaciones Descripci n and similar materials Technical Information Requested N A Conditions of reception Delivery in proper functioning order to the corresponding Health Units to the satisfaction of the Medical Director or the designated person Warranty One year warranty against faulty manufacture from date of satisfactory delivery Training N A Electrical N A No aplican Characteristics Caracter sticas El ctricas Mechanical e With tray holder including tr
70. ir de la entrega de conformidad Unidad de Proyectos MSPAS Page 63 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Delivery Kit 26 7 Equipo de partos TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS containing e 2 SIMS vaginal valves e 3 Foerster clamp with round eyelet 30 cm transfer clamp e 1 dissecting clamp with claw 30 cm e 1 dissecting clamp without claw 30 cm e 4 towel clamps 9 cm e 1 Clamp Allis 5x6 teeth 10 cm e 1 Kocher clamp Kocher straight 15 cm e 1 Kocher clamp Kocher curved 15 cm e 1 Mayo scissor straight 15 cm e 1 Mayo scissor curved 15 cm e 1 Lister Scissors 15 cm e 1 Heagar Needle Holder Heagar e 1 Stainless steel cup of 6 ounces e Circular stainless steel vessel to deposit placenta 30 cm diameter by 15 cm height Equipment Delivery Kit Equipo Equipo de partos Description One rectangular stainless steel case 1 Caja rectangular de acero inoxidable de 30 largo Descripci n size 30 cm L x 15 cm W x 5 cm H x15 cm de ancho x 5 cm de alto conteniendo 2 valvas vaginales SIMS 3 Pinza de anillo de 30 cm Pinza de transferencia 1 Pinza de disecci n con garra de 30 cm 1 Pinza de disecci n sin garra de 30 cm 4 Pinzas campo de 9 cm 1 Pinza Allis 5x6 dientes de 10 cm 1 Pinza Kocher recta de 15 cm
71. ith head and foot pieces one of them must be slidable allowing for measurements between approximately 25 cm and 100 cm 1 mm Platform table scale with capacity up to approximately 20 kg 50 Ibs Weight graduations must read in lbs and kg Minimum weight graduation 30 gm Mechanism to Equipment Scale with Height Rod Newborn B scula para reci n nacido con infant metro Equipo Location Bodega de Division de Asistencia Ubicaci n Alimentaria Secretaria de Inclusion Social SIS San Rafael Cedros Carretera llobasco Km 451 2 Description Metal cabinet with 2 doors and 2 Estructura met lica pintada con gabinete de 2 puertas y 2 gavetas Descripci n drawers Con tallimetro para medir ni os reci n nacidos y lactantes Con topes para cabeza y pies uno de ellos deslizable sobre el tablero que permita medidas comprendidas entre 25 100 cm aproximadamente 1 mm B scula de mesa con capacidad de medir hasta un aproximado de 20 Kg 50 Ibs La graduaci n de las escalas deber estar en Lbs y Kg para el peso La resoluci n m nima ser de 30 gr Mecanismo para regular b scula interna con dos manecillas de regulaci n de acero inoxidable Incluye colchoneta de espuma de 1 de espesor con tapiz resistente y de f cil limpieza de preferencia con motivos infantiles Con accesorio para colocar papel de rollo tipo toalla regulate internal platform table Unidad de Proyectos MSPAS Page 11 of 94
72. izer 1000 VA electronic type with backup of at least 20 minutes Tomacorriente polarizado grado hospitalario Tipo de seguridad el ctrica BF seg n norma IEC 60601 1 o UNE 20613 UPS con estabilizador de voltaje 1000 VA tipo electr nico con respaldo de al menos 20 minutos Mechanical Characteristics Caracter sticas Mec nicas Mobile cabinet unit supported by cabinet on castors with breaks with shelves to support printers and transducers holders The cart with which the equipment will be transported should be light high resistance and have washable paint Caracter sticas Mec nicas Equipo m vil soportado sobre gabinete con rodos y frenos con repisas para sostener impresores y sujetadores de transductores El carro sobre el que se transporta el equipo ser liviano de alta resistencia pintura lavable Technical information Required Informa ci n T cnica Requerida Operation Manual Maintenance Service Manual Manual de Operaci n Manual de Servicio Warranty Garantia Warranty covering manufacturing defects for three 3 years starting from delivery in proper functioning order to the corresponding Health Units to the satisfaction of the Medical Director or the designated party Four 4 preventive maintenance will need to be Garant a de f brica contra desperfectos de tres a os a partir de la fecha de puesta en funcionamiento del equipo a entera satisfacci n del personal que
73. la de control 1 neonatal 0 2 years old Electrical N A No aplican Characteristics Caracter sticas El ctricas Mechanical Pressure scale 0 300 mmHg 3 Rango de presi n a medir 0 300 mmHg 3 mmHg Characteristics mmHg Manga de material flexible cubierta con tela resistente Caracter sticas Cuff made of flexible material covered Columna de mercurio inclinada para perfecta lectura Mec nicas with resistant fabric tubo espirado de 2 40mts Mercury column inclined for perfect Incluye canasta para banda y perilla insufladora Unidad de Proyectos MSPAS Page 48 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 reading spiral tuve 2 40 meter long Wire basket for cuffs and bulb Conditions of Device should be delivered fully Debera entregarse funcionando en las Unidades de Reception assembled and in proper functioning Salud correspondiente a entera satisfacci n del m dico Condiciones de order to the corresponding Health Units Director o de la persona que ste designare para tal Instalaci n y to the satisfaction of the Medical efecto Recepci n Director or the designated party Technical Operation Manual Manual de Operaci n Information Parts Manual Manual de Partes required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect De un a o contra desperfectos de fabricaci n a partir de Garant a warranty from
74. les ECG heart rate monitor with range from 20 to 300 beats per minute Screen LCD TFT or electroluminescent size of 100 x 75 mm min Heart rate displayed in both numerical and wave forms Equipment Defibrillator Desfibrilador Equipo Description Portable life support Equipo port til de soporte de vida para la descarga Descripci n equipment that discharges el ctrica sincr nica o asincr nica con el fin de revertir alteraciones del ritmo y de la conducci n as como para la vigilancia de la actividad del coraz n Equipo Desfibrilador con monitor graficador de ECG con paletas externas energ a de desfibrilaci n 1 360 Joules pantalla en idioma espa ol con cable de ECG de tres electrodos monitor de ECG con medici n de ritmo card aco Con rango de 20 a 300 LPM latidos por minuto Con pantalla LCD TFT o electroluminiscente pantalla de 100 x 75 mm m nimo aproximadamente Con despliegue del valor num rico y de la onda de frecuencia card aca Alarmas visibles y audibles que puedan ser fijadas por el usuario para alteraciones en la frecuencia cardiaca conexi n del paciente y carga de la bater a Con capacidad para conexi n de paletas internas para excitaci n del m sculo card aco descarga directa prefijada a 50 Joules como m ximo Con selector de modo sincr nico cardioversi n asincr nico desfibrilaci n Con descarga desde las paletas y desde el panel de control Capaz de genera
75. ll 1 stainless steel crate 1 round or square tray 1 kidney shape bowl 2 small size bowls 1 medium size owl All instruments must be made of stainless steel 304 grade or 410 according to AISI standards or equivalent Protector de lamina de acero inoxidable calibre 18 acabado pulido Rodos tipo comercial de hule natural o sint tico macizo de 10 16 cm 4 de di metro de color negro Dimensiones aproximadas 80 cm de largo 40 cm de ancho 70 cm de alto Fabricado en acero inoxidable grado 304 seg n norma AISI o equivalente donde se indica Que incluya los siguientes accesorios 1 porta pinza que incluya pinza de anillo de 15 cm 3 tambos para torundas y gasas de acero inoxidable 3 de vidrio 2 grandes y 1 peque o 1 huacal de acero inoxidable 1 bandeja cuadrada o redonda 1 vasija arri onada 2 escudillas peque as y 1 mediana Todo el instrumental debe ser de acero inoxidable grado 304 o 410 seg n norma AISI o equivalente Fabricado bajo norma ISO 9000 como m nimo Nota Todas las dimensiones son aproximadas Unidad de Proyectos MSPAS Page 79 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Manufactured according to ISO 9000 as minimum Note all dimensions are approximate Reception Conditions Condiciones de Instalaci n Must be delivered in working order Deber entregarse de conformidad Technical Information required Informa
76. n of approximately 30 degrees e Oven dried paint Approximate dimensions e Length 1 80 meters e Width 0 55 meters e Height 0 80 meters e Polyurethane Foam Mattress 3 5 thick seamless black plastic cover washable Article Articulo Examination couch Canap para examen universal Description Table to for clinical exams in Mesa para realizar examenes clinicos en pacientes Descripci n patients Electrical N A No aplican characteristics Caracter sticas El ctricas Mechanical Minimum characteristics Caracter sticas m nimas Characteristics e Metal structure squared profile e Estructura met lica de perfil cuadrado 25 4 x 25 4 mm Caracteristicas 25 4 x 25 4 mm 1 x 1 18 1 x 1 de lamina de acero calibre No 18 acabado Mec nicas gauge steel finished in beige en pintura color beige Respaldo reclinable con una inclinaci n m xima de 60 y una posici n intermedia de 30 aproximadamente Pintado al horno Dimensiones aproximadas 1 80 metros de largo x 0 55 metros ancho x 0 80 metros alto Colchoneta espuma de poliuretano 3 5 de espesor forrado de tapiz plastico color negro sin costuras lavable Con repisa auxiliar para toma de muestras Tacos de hule antideslizantes en los cuatro apoyos del canap Unidad de Proyectos MSPAS Page 76 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 e With auxiliary shelf for drawing sampling Anti sl
77. o Descrition Chrome plated hammer handle Martillo de mango cromado de largo aproximado de 7 Descripci n approximately 7 19 cm in 3 4 19 cm con cabeza de caucho duro Con length with hard rubber head accesorios para la determinaci n de la sensibilidad de la With accessories for skin sensitivity piel determination Electrical N A No aplica Characteristics Caracter sticas El ctricas Mechanical Resistant Material De material resistente characteristics Caracter sticas Mec nicas Conditions of Reception Device should be delivered fully Deber entregarse armada y funcionando en las Condiciones de assembled and in proper Unidades de Salud correspondiente a entera Recepci n functioning order to the satisfacci n del m dico Director o de la persona que corresponding Health Units to the satisfaction of the Medical Director or the designated party ste designare para tal efecto Technical Information N A No aplica Required Informaci n T cnica Requerida Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de un a o a partir de la fecha de puesta en funcionamiento del insumo Unidad de Proyectos MSPAS Page 37 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER RENGLON DESCRIPTION DESCRIPCION QUANTITY CANTIDAD
78. of paddles a Reusable external paddles that detect electrocardiographic activity for both adult and child b External paddles for adult surface 82 cm approximately c External paddles for pediatric use surface 17 cm approximately All these paddles should be autoclavable Additional accessories a 1 set of reusable ECG electrodes cable b 12 tubes of Unidad de Proyectos MSPAS Page 18 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 conductive gel c 12 rolls of thermal paper d Suitcase and transportation cart The device is to be manufactured in accordance with standards of quality and safety for critical care hospital use In addition the device must meet internationally recognized standards of manufacture such as UL ASTM NEMA ISO IEC VDE JIS ANSI AAMI DIN or similar Should also adhere to AAMI DF2 1982 standard or the most up to date version please specify most recent update version Electric Characterisitcs Caracteristicas El ctricas Voltage 120 VAC Frequency 60 Hz Phases 1 Electric Safety in accordance with standard IEC 60601 1 UNE 20 613 or equivalent Hospital grade polarized outlet Electrical current leakage lt 100 micro amperes in the chassis lt 10 micro amperes between electrodes in accordance with the Safe Current Limits for Electro Voltaje 120 VAC Frecuencia 60 He
79. r 15 descargas a energ a m xima a una resistencia de 50 ohmios en per odo menor de 5 minutos Tiempo de carga m ximo de 8 segundos para carga de 0 Unidad de Proyectos MSPAS Page 16 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Adjustable alarm audio amp visual that can be set for heart rate change cable electrode connectivity to patient and or battery charge Capability to connect internal paddles for cardiac muscle stimulation direct discharge preset to 50 Joules as maximum Selector synchronically or asynchronous With discharge from the pallets and from control panel Capable of generating 15 discharges max energy with a resistance of 50 ohms in period lower than 5 minutes Maximum charge time of 8 seconds for charge from 0 to 360 Joules Internal back up battery with a capacity of delivering 50 defibrillations at 360 Joules or 2 hours of continuous heart rate monitoring 4 hour max charge time for back up battery Integrated thermal printer for ECG readout and events for 72 hours for at least one a 360 Joules Con bateria de reserva recargable integrada que permita dar 50 desfibrilaciones a 360 Joules o 2 horas de monitoreo continuo como minimo Tiempo de carga maximo de la bateria de 4 horas Con impresor t rmico integrado para registro de ECG y eventos en 72 horas de un canal al menos Debera contener los indicadores
80. rfectos de fabricaci n a partir de la fecha de puesta en funcionamiento del equipo Compromiso del suministrante en existencia de repuestos para un per odo m nimo de 5 a os Unidad de Proyectos MSPAS Page 43 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Aneroid Sphygmomanometer Adult Les Tensi metro Aneroide con manga para 2i adulto ni os TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS 0 300 mm of Hg calibration 3mm Hg portable with adult velcro cuff pressure control with rubber bulb control valve smooth and uniform air release For use on adult arm Complete in portable packable leather box Must include following accessories Rubber cuff for adult Rubber bulb control valve Equipment Aneroid Sphygmomanometer Tensi metro aneroide con manga para adulto Equipo Adult Description Hand aneroid Tensi metro aneroide de mano escala de 0 300 Descripci n sphygmomanometer nanometers mm Hg 3 mm Hg port til con cierre de manga por medio de banda velcro control de presi n toque pluma que permita la salida del aire de manera suave y uniforme Para uso en brazo de adulto Incluir estuche de cuero con cierre de alta durabilidad para ser utilizado con el m todo auscultatorio Deber incluir los siguientes accesorios Una manga de hule para adulto
81. ricas Mechanical Resistant case and easy to clean De carcasa resistente y de facil limpieza Characteristics Caracteristicas Mecanicas Unidad de Proyectos MSPAS Page 50 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Conditions of Device should be delivered fully Debera entregarse funcionando en las Unidades de Salud Reception assembled and in proper functioning correspondiente a entera satisfacci n del m dico Director o Condiciones de order to the corresponding Health de la persona que ste designare para tal efecto Instalaci n y Units to the satisfaction of the Recepci n Medical Director or the designated party Technical Operation Manual Manual de Operaci n Information Parts Manual Manual de Partes Required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect De un a o contra desperfectos de fabricaci n a partir de la Garant a warranty from date of satisfactory fecha de puesta en funcionamiento del equipo delivery Unidad de Proyectos MSPAS Page 51 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Manual Resuscitation Set Adult 21 7 Set de resucitador manual adulto TECHNICAL SPECIFICATION ESPECIFICACIONES TECNICAS Equipment Manual Resuscitation Set Adult Set de resucita
82. rtz Fases 1 Tipo de seguridad el ctrica de acuerdo a norma IEC 60601 1 UNE 20 613 o equivalente Tomacorriente polarizado grado hospitalario Corriente de fuga 1100 micro amperios al chasis Corriente de fuga lt 10 micro amperios entre electrodos de acuerdo con la Safe Current Limits for Electromedical Apparatus ANS Tipo de onda Low Impulso monofasico de 5 milisegundos El chasis debe estar aterrizado y la resistencia de tierra no debe ser mayor a 0 15 ohmios Unidad de Proyectos MSPAS Page 19 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Medical Apparatus ANS Wave type Low monophasic Impetus of 5 milliseconds The chassis should be should be grounded and the resistance should be no greater than 0 15 ohms Mechanical Characteristics Caracteristicas Mecanicas Portable light weight with cart for better mobility Rust resistant casing and resistant to cleaning disinfecting solutions as well Oven painted Cart with four castors and brakes on two 2 of the castors Cart should have a flat surface to place defibrillator along with cabinet and drawers to keep supplies Portatil de peso ligero con carro para mejor movilidad Carcasa resistente a la corrosi n y a l quidos de desinfecci n Pintura al horno Carro rodable para fijaci n y desplazamiento del equipo con cuatro ruedas giratorias con sistema de frenado en al
83. satisfacci n del m dico Director o Condiciones de order to the corresponding Health de la persona que ste designare para tal efecto Instalaci n y Units to the satisfaction of the Recepci n Medical Director or the designated party Technical Operation Manual Manual de Instalaci n Information Parts Manual Manual de Partes Required Informaci n T cnica Requerida Warranty One 1 year manufacturer s defect Garant a contra desperfectos de fabricaci n de un a o a Garant a warranty from date of satisfactory partir de la fecha de puesta en funcionamiento del equipo delivery Written commitment from the supplier to have spare parts in stock for a period of a minimum of five 5 years Compromiso escrito del suministrante en proveer accesorios y repuestos por un m nimo de 5 a os Unidad de Proyectos MSPAS Page 39 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGL N Nebulizer 15 7 Nebulizador TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS Equipment Nebulizer Nebulizador el ctrico para trabajo continuo de cuatro salidas Equipo Description Nebulizer for respiratory therapy Equipo de Nebulizaci n para terapia respiratoria tipo de Descripci n electric compressor piston or compresor el ctrico accionamiento por pist n o membrana de membrane opera
84. spondiente a entera satisfacci n del m dico Director o Condiciones de corresponding Health Units to the de la persona que ste designare para tal efecto Recepci n satisfaction of the Medical Director or the designated party Technical Operation Manual Manual de Operaci n information Maintenance Service Manual Manual de Servicio Required Informa ci n T cnica Requerida Warranty Three 3 year manufacturer s defect Garant a contra desperfectos de fabricaci n de tres a os a Garant a warranty from date of satisfactory partir de la fecha de puesta en funcionamiento del equipo delivery Written commitment from supplier to have spare parts in stock for a period of at least 5 years Compromiso escrito del suministrante en existencia de repuestos para un per odo m nimo de cinco a os Unidad de Proyectos MSPAS Page 8 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Bascula para adulto con tallimetro ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Scale with Height Rod Adult 3 7 TECHNICAL SPECIFICATIONS ESPECIFICACIONES T CNICAS and or springs e With easily readable markings both for weight and height integrated in the pedestal of the platform scale metal and with Equipment Scale with Height Rod Adult Bascula para adulto con tallimetro Equipo Description Pedestal scale solid platform with D
85. tion high alta durabilidad para trabajo continuo Para instalar y manejar durability for continuous hasta 4 puestos de trabajo con flujos de trabajo para operation nebulizaci n completamente independientes Compatible with installation and management of 4 completely Incluir independent nebulizing stations e 100 micronenebulizadores e 50 mascarillas adultos Accessories e 50 mascarillas pedi tricas e 100 micronenebulizers e 50 adult masks e 50 pediatric masks Electrical e Voltage 120 VAC Voltaje 120 VAC 60 Hertz characteristics e Frequency 60 Hz Fases 1 Caracteristicas e Phases 1 Tomacorriente macho polarizado grado hospitalario El ctricas e Male plug polarized hospital Longitud del cord n 3 mts m nimo grade Tipo de seguridad el ctrica H seg n norma UNE 20 613 6 e Powercord length 3 meters equivalente minimium e Electrical safety H according to UNE 20 613 standards or equivalent Mechanical Portable silent operation oil free Port til operaci n silenciosa libre de aceite resistente a la Characteristics rust resistant enamel paint with corrosi n pintura esmalte con las siguientes caracter sticas Unidad de Proyectos MSPAS Page 40 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Caracteristicas following characteristics Flujo 20 litros min Mecanicas e Flow 20 liters min Tasa media de Nebulizaci n 0 25 ml min m nimo e Average
86. triles de acero inoxidable de dos e Width 0 60 m ganchos para colocar soluciones a ambos lados de la cabecera e Ruedas de 4 m nimo de di metro de caucho conductivo con freno en las ruedas e Parachoques de alto impacto y protecci n de choques en todo el per metro Unidad de Proyectos MSPAS Page 74 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 e Dimensiones aproximadas Altura 0 80 m Largo 1 95 m Ancho 0 60 m Reception Conditions Condiciones Recepci n de Device should be delivered fully assembled and in proper functioning order to the Responsible Party according to distribution matrix Deber entregarse a entera satisfacci n de la Jefatura del rea seg n matriz de distribuci n Warranty Garant a One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de dos a os a partir de la fecha de entrega de conformidad Unidad de Proyectos MSPAS Page 75 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Examination Couch 33 21 Canap para examen universal TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS color paint e Reclining back with a tilt of 60 degrees maximum and an intermediate positio
87. ubierta lisa de lamina de acero inoxidable cal 16 con Mec nicas e Covered in smooth stainless respaldo acabado pulido 3 Puerta de lamina de acero cal 20 acabado en pintura color gris 4 Regat n de aluminio de 25 mm 1 de di metro con altura ajustable 5 Tubo de acero cal 18 de 32 x 32 mm 1 Y x 1 1 4 acabado en pintura color gris Dimensiones aproximadas 70 cm de largo 40 cm de ancho y 90 cm de alto Fabricado en acero inoxidable grado 304 o mejor seg n norma AISI o equivalente Unidad de Proyectos MSPAS Page 81 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 or better according to AISI standard or equivalent Technical Information N A No aplica Required Informaci n T cnica Requerida Warranty Garantia One 1 year manufacturer s defect warranty from date of satisfactory delivery Garant a contra desperfectos de fabricaci n de un a o a partir de la entrega de conformidad Unidad de Proyectos MSPAS Page 82 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 ITEM NUMBER DESCRIPTION DESCRIPCION QUANTITY CANTIDAD RENGLON Step Ladder 36 20 Gradilla de dos peldanos TECHNICAL SPECIFICATIONS ESPECIFICACIONES TECNICAS Article Articulo Step Ladder Gradilla de dos pelda os Description Metal step ladder with two rungs Es
88. udes standard 60 watt lightbulb e Mechanical Characteristics Rust resistant metal pedestal with adjustable height between 85 cm and 150 cm Powercord length 2 meters min Device should be delivered in proper functioning order to the corresponding Health Units to the satisfaction of the Medical Director or the designated person Technical Information Requested N A L mpara para examen tipo cuello de ganso flexible giratoria con pantalla reflejante que incremente la intensidad y uniformidad de la luz Para uso en consultorio Montada en pedestal con altura regulable Incluye foco incandescente est ndar de 60 watts Unidad de Proyectos MSPAS Page 29 of 94 ESPECIFICACIONES TECNICAS DE EQUIPO TECNICAS TECHNICAL SPECIFICATIONS AUGUST 2011 Electrical e Voltage 120 V Voltaje 120 V Characteristics e Frequency 60 Hz Frecuencia 60 Hz Caracteristicas e Phases 1 Fases 1 El ctricas e Output 60 watts Potencia 60 watts e Hospital Grade Polarized Socket Toma Polarizado grado hospitalario Electrical safety H according to UNE Tipo de seguridad el ctrica H segun norma UNE 20 613 IEC 601 1 standards or 20 613 equivalente equivalent Mechanical Resistant metal pedestal with De metal resistente autosoportada en pedestal Characteristics adjustable height between 85 cm and cuerpo flexible con altura regulable 85 150 cm Caracteristicas 150 cm Cord n de alimentaci n de 2 m como m nimo Mec
Download Pdf Manuals
Related Search
Related Contents
Hewlett Packard Enterprise A A8760 Dual Radio 802.11a/b/g 取扱説明書 2014. 5 miolo frente EX-wordテキストローダー 取扱説明書 Silvercrest KH 2398 Clock Radio User Manual Installatiehandleiding Installation manual White Rodgers 11D37 User's Manual User`s Manual - Thomson Automation ASUS EeeBox PC EB1505-B027M Mini-Dynorbital® Supreme Copyright © All rights reserved.