Home

INSTRUCTION MANUAL - Medical Devices Center

image

Contents

1. INSTRUCTION BK PRECISION MANUAL MODEL 4010A MANUAL DE USUARIO MODELO 4010A 2 MHz FUNCTION GENERATOR 2MHz GENERADOR DE FUNCIONES BK PRECISION TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be performed where exposed voltage is present An electrical shock causing 10 milliamps of current to pass through the heart will stop most human heartbeats Voltage as low as 35 volts de or ac rms should be considered dangerous and hazardous since it can produce a lethal current under certain conditions Higher voltages pose an even greater threat because such voltage can more easily produce a lethal current Your normal work habits should include all accepted practices to prevent contact with exposed high voltage and to steer current away from your heart in case of accidental contact with a high voltage You will significantly reduce the risk factor if you know and observe the following safety precautions 1 Don t expose high voltage needlessly Remove housings and covers only when necessary Turn off equipment while making test connections in high voltage circuits Discharge high voltage capacitors after removing power 2 If possible familiarize yourself with the equipment being tested and the location of its high voltage points However remember that high voltage may appear at unexpected points in defective equipment
2. la frecuencia preseleccionada por los switches de rango y los controles de frequencia Aplicando aproximadamente 10V con el control COARSE a rotaci n completa en la direcci n del reloj se disminuye la frecuencia de salida por cerca de 100 veces un factor de100 1 26 INSTRUCCIONES DE OPERACI N 1 Seleccione el rango de frequencia deseado y la forma de onda 2 Ajuste la frecuencia de inicio con el control FREQUENCY Aplique un voltaje de DC positivo al jack VCG SWEEP 9 de entrada para disminuir la frecuencia Un voltaje de 0 a 10 V causa que la frecuencia disminuya por un factor de100 si el control se rota a su maximo Por ejemplo si la frecuencia de inicio es de 200 kHz aplicando 10 V cambiar la frecuencia de salida a 2kHz 1 Para usar el generador de funciones como un generador de barrido aplique una se al de rampa al jack de entrada VCG INPUT Cuando el voltaje de rampa aumenta la frecuencia disminuye La velocidad de barrido puede ajustarse variando la frecuencia de la se al de rampa 2 Puede seleccionar frecuencias espec ficas aplicando un voltaje de DC fijo al jack VCG IMPUT o las frecuencias pueden ser escalonadas aplicando un voltaje de DC escalonado 3 No aplique mas de 15 volts DC o DC AC pico al jack VCG INPUT jack Entradas de mAs de 15 volts no var an m s la frecuencia y podr an ocasionar da os al generador INSTRUCCIONES DE OPERACION CONSIDERACIONES DE PROTECCION DE SALIDA Tenga cu
3. Voltage Controlled Generator input Permits external control of generator output frequency by a DC voltage input at this jack A positive voltage will decrease frequency DUTY CYCLE Control Enabled by the DUTY CYCLE Switch 14 Rotation from center position adjusts the duty cycle of the main OUTPUT signal 20 dB Switch When engaged the signal at the OUTPUT jack is attenuated by 20 dB DC OFFSET Switch When engaged enables operation of the DC OFFSET control 5 CMOS LEVEL Switch When engaged changes the TTL signal to CMOS signal at the TTL CMOS jack DUTY CYCLE Switch When engaged enables operation of DUTY CYCLE control 10 FREQUENCY Control Adjustment of the output frequency from 0 1 to 1 times the selected range INV Allows the user to invert the polarity of the normal output signal CONTROLS AND INDICATORS 13 12 1 Figure 1 Model 4010A Controls and Indicators 9 OPERATING INSTRUCTIONS The B K Precision Model 4010A Function Generator is a versatile instrument capable of producing a variety of output waveforms over a broad range of frequencies To gain a working familiarity with the unit it is recommended that it be connected initially to an oscilloscope so that the effects of the various controls on the output waveforms can be observed Use this manual as required for reference until becoming accustomed to the operating procedures FREQUENCY AND WAVEFORM SELECTION 1 Initially verify that the DUT
4. FREQUENCY control as required Pulse Square Il Ramp 06 ii Ne Siawed Sine Figure 4 Effects of Symmetry Variation 12 OPERATING INSTRUCTIONS TTL CMOS OUTPUT The TTL CMOS output jack provides a fast rise time square wave output Either a fixed TTL or a variable CMOS output level is available The output is positive with respect to ground and can be used as an external sync pulse for oscilloscopes or as a variable frequency signal source for exercising logic circuits Because of the fast rise time of this output cable length should be minimized to limit ringing and overshoot Select the desired frequency range and adjust the frequency controls as required The OUTPUT LEVEL and DC OFFSET controls have no effect on the signal at the TTL CMOS jack When the CMOS LEVEL switch 13 is OFF a TTL signal is output at the TTL CMOS jack Select a CMOS signal by engaging the CMOS LEVEL switch and adjust the level of the signal by rotating the CMOS LEVEL control 8 VOLTAGE CONTROLLED FREQUENCY OPERATION The Model 4010A can be operated as a voltage controlled generator by using an external control voltage applied to the VCG INPUT jack The externally applied voltage will vary the frequency which is preselected by the range switches and the frequency controls Applying approximately 10 V with the FREQUENCY control at full clockwise decreases the output frequency by about 100 times a 100 1 ra
5. Seleccione la onda de forma deseada SINE SQUARE TRIANGLE oprimiendo uno de los switches de FUNCTION 3 Sus relaciones de fase se muestran en la figura 2 4 Seleccione la frecuencia de la onda de forma oprimiendo uno de los switches RANGE 2 5 Gire el control FREQUENCY 15 para fijar la frecuencia de salida r pidamente al valor deseado La frecuencia seleccionada estar disponible en el jack OUTPUT 6 Adem s una se al digital estar presente en el jack TTL MOS 7 Refi rase a la se al TTL CMOS OUTPUT de este manual 23 mi inizio nnt e sisi dde Figura 2 Formas de onda de salida y relaci n de frase 6 Ajuste la amplitud de la salida como desee usando el control OUTPUT LEVEL 4 Nivel de salida La rotaci n de este control var a la amplitud desde el m ximo hasta 20 dB debajo del m ximo Una atenuaci n adicional de 20dB esta disponible oprimiendo el 20dB switch 11 Los factores de atenuaci n pueden ser combinados por un total de 40dB El m ximo nivel de se al es de 10V p p con carga de 50 Ohms 7 Un componente de DC puede sumarse a la se al de salida oprimiendo el switch DC OFFSET 12 para activar la operaci n del control DC OFFSET 5 La rotaci n de este control afiade una componente de DC positiva o negativa a la sefial de salida La componente de DC introducido es independiente del control OUTPUT LEVEL y puede variarse 10 voltios en circuito abierto o 5 voltios a trav s de
6. como se muestra en las ondas superiores de cada par de la Fig 4 La rotaci n contraria produce las formas de onda inferiores de cada par 3 Las variaciones del ciclo de servicio producen cambios ligeros de la frecuencia Ajuste el control como se requiera 25 Pulso Cuadrado is fa gt 2 Rz et Seno Inciinado PAR AA Figura 4 Efectos de variaci n de simetr a SALIDA TTL CMOS El jack de salida TTL CMOS presenta una sefial cuadrada de tiempo de levantamiento rapido con un nivel fijo TTL o variable CMOS La salida es positiva respecto a tierra y puede usarse como pulso externo de sincronizaci n para osciloscopios o como fuente de frecuencia variable para probar circuitos l gicos Dado el r pido tiempo de levantamiento se recomienda usar cables cortos para minimizar transitorios o sobre impulsos 4 Seleccione el rango de frecuencia deseado y ajuste los controles de frecuencia como requiera Los controles OUTPUT LEVEL y DC OFFSET no producen efecto alguno en la se al TTL CMOS 5 Cuando el switch CMOS LEVEL 13 se desactiva se produce una se al TTL en el jack Seleccione una se al CMOS accionando el switch CMOS LEVEL y ajuste el nivel de la se al girando el control CMOS LEVEL 8 OPERACION DE LA FRECUENCIA CONTROLADA POR VOLTAJE El modelo 4010A puede ser operado como un generador controlado por voltaje aplicando al jack VCG SWEEP de entrada un voltaje externo de control Dicho voltaje variar
7. in the engineering manufacturing servicing educational and hobbyist fields SPECIFICATIONS FREQUENCY CHARACTERISTICS SINE WAVE Waveforms Sine Square Triangle Pulse Ramp Distortion Range 4 typical at 1 kHz 0 2 Hz to 2 MHz in 7 ranges Flatness Dial Accuracy 5 0 45 dB 45 5 Tuning Range SQUARE WAVE 10 1 Variable Duty Cycle 15 85 15 Continuously Variable Symmetry Operating Modes 2 0 2 Hz to 100 kHz Normal VCG Voltage Controlled Generator Rise Time lt 120 nS OUTPUT CHARACTERISTICS Impedance TRIANGLE WAVE 50 Q 10 Level Linearity 20 V p p Open circuit 10 V p p into 500 Amplitude Control Variable 20 dB range typical 298 to 100 kHz Attenuation 20 dB 1 dB DC Offset Preset 0 1 V typical Variable 10V open circuit 5V into 50 Q SPECIFICATIONS TTL OUTPUT POWER SOURCE Level 0 8 V to 2 4 V 120 230 VAC 10 50 60 Hz internal jumper Rise Time lt 20 nS selectable Duty Cycle 50 typical DIMENSIONS H x W x D CMOS OUTPUT 4 1 2 x 10 1 2 x 12 1 4 26 7cm x 11 4cm x 31 1cm Level 4 V to 14 V 0 5V p p Continuously Variable Rise Time lt 50 nS WEIGHT 4 1 lb 1 845 kg VCG Voltage Controlled Generator INPUT ACCESSORIES Input Voltage 0 10 V 1 V causes a 100 1 frequency change Instruction Manual Impedance Output Cable BNC to Alligator Clips 10kQ 5 NOTE Specifications and information are subject to change without notice Please
8. large DC offset is required an oscilloscope should be used to make sure that the 5 desired signal is obtained without undesirable clipping A more precise frequency setting may be achieved by connecting an external frequency counter to the TTL or output jack When outputting square waves or when using the TTL output terminate the cable into 50 Q to minimize ringing Also keep cables as short as possible 11 OPERATING INSTRUCTIONS DUTY CYCLE CONTROL The DUTY CYCLE control can be used to alter the symmetry of the output waveform to produce waveshapes such as those shown in Fig 4 For a square wave symmetry variation amounts to changing the duty cycle ratio of high to low time effectively converting the instrument into a pulse generator For a triangle wave the result is a ramp and with a sine wave a distorted waveshape called a slewed sine is produced The Model 4010A provides for symmetry variation from 15 to 85 1 Select the waveform desired either SINE SQUARE or TRIANGLE 2 Engage the DUTY CYCLE switch 14 and adjust the DUTY CYCLE control 10 for the desired waveshape Clockwise rotation from center results in an increase in square wave duty cycle and changes the sine and triangle waves as shown in the top waveform of each pair of Fig 4 Counter clockwise rotation results in the bottom waveform in each pair 3 Varying the duty cycle setting results in a slight change in frequency Adjust the
9. onda del jack de salida senoidal cuadrada triangular en el jack OUTPUT de salida CONTROL DE NIVEL DE SALIDA OUTPUT LEVEL Controla la amplitud de la se al al jack de salida El nivel de salida puede ser disminuido por aproximadamente 20dB con este control CONTROL DE DC OFFSET Activado por el switch de OFFSET 12 La rotaci n en la direcci n de las manecillas del reloj desde el centro cambia el desplazamiento de DC en la direcci n positiva en tanto que la rotaci n en contra de las manecillas del reloj desde el centro cambia el desplazamiento de DC en la direcci n negativa JACK DE SALIDA OUTPUT La forma de onda seleccionada por el switch de funciones as como el voltaje de desplazamiento de DC sobre impuesto est disponible en este jack Jack TTL CMOS Onda cuadrada TTL o CMOS dependiendo de la posici n del switch 13 de nivel CMOS Esta salida es independiente del los controles de OUTPUT LEVEL y OFFSET CD 21 CONTROL DE NIVEL CMOS LEVEL Girando este control en la direcci n de las manecillas del reloj aumenta la amplitud de la se al CMOS al jack TTL CMOS Jack de entrada VCG Permite el control externo de la frecuencia de salida del generador por un voltaje de DC aplicado a este jack Un voltaje positivo disminuir la frecuencia CONTROL DEL CICLO DE SERVICIO DUTY CYCLE Activado por el switch DUTY CYCLE 14 La rotaci n desde la posici n central ajusta el ciclo de servicio de la se al de la salida
10. principal OUTPUT 20 DB SWITCH Al accionarse la se al del jack de salida es atenuada por 20 dB Switch DC OFFSET Al accionarse se habilita la operaci n del control DC OFFSET 5 Switch CMOS LEVEL Accionado cambia la se al TTL a se al CMOS en el jack TTL CMOS Switch DUTY CYCLE Su activaci n habilita la operaci n del control DUTY CYCLE 10 Control FREQUENCY Ajusta la frecuencia de salida de 0 1 a 1 del rango seleccionado INV Permite invertir la polaridad de la se al normal de salida CONTROLES E INDICADORES 13 12 1 Figura 1 Panel frontal del modelo 4010 22 INSTRUCCIONES DE OPERACION El Generador de funciones B amp K Precison Modelo 4010A es un instrumento versatil capaz de producir una variedad de formas de onda con un amplio rango de frecuencias Para familiarizarse con esta unidad se recomienda conectarla inicialmente a un osciloscopio para observar los efectos de los controles en las formas de onda generadas Use este manual seg n requiera como referencia hasta que domine los procedimientos de operaci n SELECCION DE FRECUENCIA Y FORMA DE ONDA 1 Inicialmente verifique los switches DUTY CYCLE 14 CMOS LEVEL 13 DC OFSSET 12 y 20dB 11 est n desactivados Esto producir una onda sim trica no afectada por el generador de barrido y otros controles 2 Enchufe la unidad en una fuente de energ a apropiada y enci ndalo oprimiendo el switch POWER 1 3
11. stica de seguridad para mantener la caja u otros elementos expuestos a tierra 8 Los productos B amp K Precision no est n autorizados para uso en cualquier aplicaci n que involucre el contacto directo con el cuerpo humano o para el uso como un componente critico en un dispositivo o sistema para el soporte de vida Aqu contacto directo se refiere a cualquier conexi n de o a nuestro equipo a trav s de cualquier cableado o interruptores Un componente critico es cualquier componente de un dispositivo de soporte de vida o sistema cuyo fallo pueda causar una falla del dispositiva o sistema o afecte su seguridad o efectividad 9 Nunca trabaje solo Alguien debe de estar cerca para prestar ayuda de ser necesario Entrenamiento en primeros auxilios CPR resucitaci n cardiopulmonar se recomienda ampliamente 32 BK PRECISION Declaration of CE Conformity according to EEC directives and NF EN 45014 norm Responsible Party Alternate Manufacturing Site Manufacturer s Name B amp K Precision Corporation B amp K Taiwan 0574 Manufacture s Address 22820 Savi Ranch Pkwy Yorba Linda CA 92887 4610 USA Declares that the below mentioned product Product Name Function Generator Part Numbers 4010A 4011A 4012A 4040A 4017A complies with the essential requirements of the following applicable European Directives Low Voltage Directive 73 23 EEC 19 02 73 amended by 93 68 EEC 22 07 93 Electromagnetic Compatibility EMC
12. visit www bkprecision com for the most current product information CONTROLS AND INDICATORS FRONT PANEL Refer to Fig 1 1 POWER Switch Turns power on and off 2 RANGE Switch Selects output frequency range Seven TTL CMOS Jack TTL or ranges from 2 Hz to 2 MHz Switch indicates maximum frequency of range and is adjusted with FREQUENCY control to 0 1 times the maximum For example if the 200 kHz range is selected the output frequency can be adjusted from 20 kHz to 200 kHz FUNCTION Switch Selects sine square or triangle waveform at OUTPUT jack OUTPUT LEVEL Control Controls the amplitude of the signal at the OUTPUT jack Output level can be decreased by approximately 20 dB with this control DC OFFSET Control Enabled by the DC OFFSET Switch 12 Clockwise rotation from center changes the DC offset in a positive direction while counterclockwise rotation from center changes the DC offset in a negative direction OUTPUT Jack Waveform selected by FUNCTION switch as well as the superimposed DC OFFSET voltage is available at this jack CMOS square wave depending on the position of the CMOS LEVEL switch 13 is output at this jack This output is independent of the OUTPUT LEVEL and DC OFFSET controls 8 9 10 11 12 13 14 15 16 CMOS LEVEL Control Rotating this control clockwise increases the amplitude of the CMOS square wave at the TTL CMOS jack VCG Jack
13. 3 Use an insulated floor material or a large insulated floor mat to stand on and an insulated work surface on which to place equipment and make certain such surfaces are not damp or wet 4 Use the time proven one hand in the pocket technique while handling an instrument probe Be particularly careful to avoid contacting a nearby metal object that could provide a good ground return path 5 When testing ac powered equipment remember that ac line voltage is usually present on some power input circuits such as the on off switch fuses power transformer etc any time the equipment is connected to an ac outlet even if the equipment is turned off continued on inside back cover Instruction Manual for MODEL 4010A 2 MHz FUNCTION GENERATOR BK PRECISTON 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com TABLE OF CONTENTS page page TEST INSTRUMENT SAFETY inside front cover MAINTENANCE 15 INTRODUCTION 22 2er nn E 5 Fuse Replacement iii 15 SPECIFICATIONS 6 Function Generator Guidebook 15 CONTROLS AND INDICATORS nennen 8 CUSTOMER SUPPORT 16 OPERATING INSTRUCTIONS ann 10 SERVICE saan eens 17 Frequency and Waveform Selection 10 TITER TWO ER WARRANTY a e 18 a 11 SP
14. 4010A is overload protected so that shorting the output even continuously will not cause damage A fuse has been added in series with the OUTPUT jack to help protect the instrument from damage by connection to excessive external voltage Damage of this type usually occurs by accidentally connecting the output of the function generator to a voltage in the equipment under test The following protective measures are strongly recommended 1 The user should understand the equipment under test well enough to identify valid signal injection points i e the base of a transistor a logic input of a gate etc The voltage at valid signal injection points is rarely high enough to damage the instrument OPERATING INSTRUCTIONS 2 If in doubt about the safety of a signal injection point measure the voltage present at the intended point of signal injection before connecting the function generator output to that point When applying the main output of the function generator to a circuit point containing a dc level adjust the DC OFFSET control so that the dc level at the main output matches the circuit voltage Connect the TTL output only to TTL level circuits Connect the CMOS output only to CMOS circuits Measure the Vcc of the circuit under test and adjust the CMOS LEVEL control as instructed in the manual When the function generator is used by students or other inexperienced users the circuit of Fig 5 could be added into your TT
15. 50 ohms El desplazamiento de DC no afecta al jack de salida TTL CMOS El efecto del desplazamiento se muestra en la Fig 3 CONSIDERACIONES 1 La rotaci n contra el reloj del control FREQUENCY reduce la frecuencia de salida por un factor aproximado de 10 1 del rango seleccionado Por ejemplo en el rango de 20K el giro completo del dial en contra de las manecillas reduce la frecuencia a 2KHz aproximadamente 2 La rotaci n del control en sentido del reloj aumenta la frecuencia hasta el valor tope del rango Esto es si selecciona el rango de 20K y el dial se fija en 2 0 la frecuencia ser de 20KHz 3 Con el dial en 1 0 la frecuencia de salida es aproximadamente la mitad del rango seleccionado As en el rango de 20K y el dial en 1 0 la salida es de 10KHz 4 Para mayor precisi n conecte un contador externo de frecuencia a los jacks de salida TTL u OUTPUT 5 Cuando genere ondas cuadradas o utilice la salida de TTL termine el cable en 50 ohms para disminuir oscilaciones transitorias Tambi n use cables tan cortos como sea posible 24 INSTRUCCIONES DE OPERACI N A Desplazamiento cero de DC Con se al m xima B Limites del desplazamiento sin truncamiento Desplazamiento Desplazamiento DC positivo DC negativo C Desplazamiento excesivo Desplazamiento DC positivo Desplazamiento DC negativo Figura 3 Uso del control DC OFFSET 6 Recuerde que la variaci n de la se al de salida de gen
16. 89 336 EEC 03 05 88 amended by 92 68 EEC 22 07 93 and conforms with the following product standards Safety EN 61010 1 2001 EMC EN 61326 1997 A1 1998 A2 2001 EN 50081 1 EN 50081 2 This Declaration of Conformity applies to above listed products place on the EU market after era February 4 2005 oa Tole Date Victor Tolan President BK PRECISTON 22820 Savi Ranch Parkway Yorba Linda CA 92887 2005 B K Precision 480 748 9 100 Printed in U S A
17. ANISH MANUAL 20 Duty Cycle Control 12 TTL CMOS Output cecccecceeceecceeeeeeeeereeenes 13 Voltage Controlled Frequency Operation 13 Output Protection Considerations 14 Function Generator Applications Guidebook 14 INTRODUCTION The B K Precision Model 4010A Function Generator is a versatile signal source which combines several functions into one unit A calibrated dial provides frequency accuracy within 5 High stability assures that the output frequency does not drift The heart of the function generator is a VCG voltage controlled generator that produces precision sine square or triangle waves over the 0 2 Hz to 2 MHz range This encompasses subaudible audio ultrasonic and RF applications A continuously variable dc offset allows the output to be injected directly into circuits at the correct bias level Variable symmetry of the output waveform converts the instrument to a pulse generator capable of generating rectangular waves or pulses ramp or sawtooth waves and slewed sine waves In addition to the above features an external signal may be used to sweep the output frequency or control operating frequency This is useful in situations where an externally controlled frequency is desirable With this versatility the unit has a vast number of applications in both analog and digital electronics
18. L output probe or test clip set It will protect the TTL output of the generator against external voltages up to 20 volts TTL FUNCTION GENERATOR TO TTL OUTPUT CIRCUIT GROUND Figure 5 Circuit for Protection of TTL Output FUNCTION GENERATOR APPLICATIONS GUIDEBOOK B K Precision offers a Guidebook to Function Generators which describes numerous applications for this instrument including hook up details It also includes a glossary of function generator terminology and an explanation of function generator circuit operation It maybe downloaded for free off our website at www bkprecision com 14 MAINTENANCE WARNING The following instructions are for use by qualified service personnel only To avoid electrical shock do not perform servicing other than contained in the operating instructions unless you are qualified to do so Remember that ac line voltage is present on line voltage input circuits any time the instrument is plugged into an ac outlet even if turned off Always unplug the function generator before performing service procedures FUSE REPLACEMENT 1 Locate the fuse holder on the input line receptacle 2 Remove the fuse holder and replace the fuse with an equal value fuse 15 INSTRUMENT REPAIR SERVICE Because of the specialized skills and test equipment required for instrument repair and calibration many customers prefer to rely upon B K PRECISION for this service We maintain a n
19. Y CYCLE 14 CMOS LEVEL 13 DC OFFSET 12 20dB 11 switches are in the OUT position released This will produce a symmetrical waveform unaffected by the other controls 2 Plug the unit into an appropriate power source and turn it on by engaging the POWER switch 1 3 Select the desired waveform SINE SQUARE or TRIANGLE by engaging one of the FUNCTION switches 3 Phase relationships of the waveforms are shown in Fig 2 4 Select the frequency of the waveform by engaging one of the RANGE switches 2 5 Rotate the FREQUENCY control 15 to set the output frequency to the desired value The frequency selected is available at the OUTPUT jack 6 In addition a digital signal either TTL or CMOS is available at the TTL CMOS jack 7 refer to the TTL CMOS OUTPUT section of this manual 10 Figure 2 Output Waveform and Phase Relationship 6 Adjust the amplitude of the output as desired using the OUTPUT LEVEL control 4 Rotation of this control varies the amplitude from maximum to 20 dB below maximum An additional attenuation of 20 dB is available by pushing in the 20dB switch 11 The attenuation factors can be combined for a total of 40 dB The maximum signal level is 10 V p p into 50 Q OPERATING INSTRUCTIONS 7 A superimposed DC component can be added to the output signal by engaging the DC OFFSET switch 12 to enable operation of the DC OFFSET control 5 Rotation of this control adds a posi
20. a que el voltaje se salida iguale al voltaje del circuito 4 Conecte la salida de TTL solo a circuitos de nivel TTL Conecte la salida de CMOS solo a circuitos CMOS Mida el voltaje Vcc del circuito bajo prueba y ajuste el control CMOS LEVEL como se indica en el manual 5 Cuando el generador de funciones es usado por estudiantes u otros usuarios sin experiencia el circuito mostrado en Fig 5 puede ser a adido a su sonda de la salida TTL o al juego de clips de prueba Esto proteger las salidas TTL del generador contra voltajes externos hasta de 20 volts 150 0 2 W TTL Generador de Funci n Al Salida TTL Circuito Figura 5 Circuito de protecci n para la salida TTL LIBRO GUIA DE APLICACIONES DE EL GENERADOR DE FUNCIONES 27 B amp K Precision ofrece una Gu a del Generador de Funciones que describe numerosas aplicaciones de este instrumento incluyendo detalles de conexi n Tambi n incluye un glosario de la terminolog a del generador de funciones y una explicaci n de la operaci n de su circuito Puede ser descargado gratis de nuestra Web site en www bkprecision MANTENIMIENTO PRECAUCION Las siguientes instrucciones son para uso solo por personal de servido calificado Para evitar choque el ctrico no haga servicios distintos al contenido en las instrucciones de operaci n a menos que est calificado para hacerlo Recuerde que la l nea de voltaje de AC est presente en los circuitos de entrada
21. calibraci n e Pedidos de partes de reemplazo e Disponibilidad de publicaciones de servicio e Informaci n sobre otros instrumentos de B K Precision e Solicitudes de cat logos de B K Precision e nombre de su distribuidor m s cercano Llame sin cargo 800 462 9832 29 BK PRECISION SISI Informacion de Servicio Servicio de Garant a Por favor regrese el producto en el empaquetado original con prueba de la fecha de la compra a la direcci n debajo Indique claramente el problema en escritura incluya todos los accesorios que se estan usado con el equipo Servicio de No Garant a Por favor regrese el producto en el empaquetado original con prueba de la fecha de la compra a la direcci n debajo Indique claramente el problema en escritura incluya todos los accesorios que se estan usado con el equipo Clientes que no tienen cuentas deben de incluir pago en forma de queque orden de dinero o numero de carta de cr dito Para los precisos mas corriente visite www bkprecision com y oprime service repair Vuelva toda la mercanc a a B amp K Precision Corp con el env o pagado por adelantado La carga global de la reparaci n para el servicio de la No Garant a no incluye el env o de vuelta El env o de vuelta a las localizaciones en norte americano es incluido para el servicio de la garant a Para los env os de noche y el env o del no Norte los honorarios americanos satisfacen el contacto B amp K Precision Corp B amp K P
22. continu la cubierta de espalda MANUAL DE USUARIO MODELO 4010A 2MHz GENERADOR DE FUNCIONES BK PRECISION 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com TABLA DE CONTENDIDO Pagina SEGURIDAD DEL INSTRUMENTO DE PRUEBA Segunda de forros IN TRODUGION rioni 18 ESPECIFICACIONES 219 CONTROLES E INDICADORES PAOA INSTRUCCIONES DE OPERACI N 28 Selecci n de frecuencia y forma de onda Consideraciones oe 24 Control de ciclo de servicio ii 25 Salida para TT E CMOS vais pain as i 26 Operaci n de la frecuencia controlada por voltaje 26 Consideraciones de protecci n de Salida see 27 Guia de aplicaciones del generador de funciones 27 P gina MANTENIMIENTO cirie 28 Desensamblado y reensamblado 28 Reemplazo de fusible 28 Selecci n de linea de 28 SOPORTE AL CLIENTE 29 INFORMACI N DE SERVICIO GARANTIA LIMITADA DE DOS A OS INTRODUCCION El amp K Precision modelo 4010A generador de funciones es una versatil fuente de sefiales que combina varias funciones en una unidad Un dial calibrado provee una precision de frecuenc
23. damage to test instruments or the equipment under test may result from connecting the ground lead of most test instruments to a hot chassis To test hot chassis equipment always connect an isolation transformer between the ac outlet and the equipment under test The B K Precision Model TR 110 or 1604 Isolation Transformer or Model 1653 or 1655 AC Power Supply is suitable for most applications To be on the safe side treat all two wire ac equipment as hot chassis unless you are sure it has an isolated chassis or an earth ground chassis 7 On test instruments or any equipment with a 3 wire ac power plug use only a 3 wire outlet This is a safety feature to keep the housing or other exposed elements at earth ground 8 Never work alone Someone should be nearby to render aid if necessary Training in CPR cardio pulmonary resuscitation first aid is highly recommended 19 SEGURIDAD DEL INSTRUMENTO DE PRUEBA PRECAUCIONES El Uso normal de equipo de prueba lo expone a cierto riesgo de choque el ctrico cuando efect a pruebas donde hay alto voltaje descubierto Un choque el ctrico que cause una corriente de 10 mili amperes a trav s del coraz n parar a la mayor a de los corazones humanos Un voltaje tan bajo como de 35 volts DC o AC rms podr a considerarse de peligro porque puede producir una corriente letal bajo ciertas condiciones Voltajes mayores pueden ser aun m s peligrosos Sus h bitos normales de trabajo deben de inc
24. erador esta limitada a 10 volts en circuito abierto o 5 volts en 50 ohms y aplica a la se al combinada pico a pico con el desplazamiento DC El truncamiento ocurre ligeramente arriba de estos niveles La Fig 3 ilustra diversas condiciones de operaci n posibles al introducir el desplazamiento DC Si la amplitud de la se al o el desplazamiento DC son grandes utilice un osciloscopio para asegurar que la se al deseada no presenta un truncamiento indeseable INSTRUCCIONES DE OPERACION CONTROL DUTY CICLE CICLO DE SERVICIO El control DUTY CYCLE puede usarse para alterar la simetr a de la forma de onda de salida y generar ondas de forma tales como las mostradas en la Fig 4 Para una onda cuadrada la variaci n de simetr a equivale a cambiar el ciclo servicio raz n del tiempo alto al bajo efectivamente convirtiendo al instrumento en un generador de pulsos Para una onda triangular el resultado es una rampa y para una onda senoidal obtenemos una onda distorsionada llamada seno inclinado El Modelo 4011A permite la variaci n de simetr a desde 15 hasta 85 1 Seleccione la onda de forma deseada sea SENOIDAL CUADRADA o TRIANGULAR 2 Active el switch DUTY CYCLE 14 y ajuste el control DUTY CYCLE 10 para obtener la forma de onda deseada La rotaci n desde el centro en sentido de las manecillas del reloj incrementa el ciclo de servicio en una onda cuadrada y modifica las ondas de seno y triangulo
25. etwork of B K PRECISION authorized service agencies for this purpose To use this service even if the instrument is no longer under warranty follow the instructions given in the WARRANTY SERVICE INSTRUCTIONS portion of this manual There is a nominal charge for instruments out of warranty CUSTOMER SUPPORT 1 800 462 9832 B K Precision offers courteous professional technical support before and after the sale of their test instruments The following services are typical of those available from our toll free telephone number Technical advice on the use of your instrument Technical advice on special applications of your instrument Technical advice on selecting the best instrument for a given task Information on optional accessories for your instrument Information on instrument repair and recalibration services Replacement parts ordering Availability of service publications Information on other B K Precision instruments Requests for a new B K Precision catalog The name of your nearest B Precision distributor Call toll free 1 800 462 9832 Monday through Thursday 8 00 A M to 5 00 P M Friday 8 00 A M TO 11 30 A M Pacific Standard Time Pacific Daylight Time summer 16 BK PRECISION y Service Information Warranty Service Please return the product in the original packaging with proof of purchase to the address below Clearly state in writing the performance problem and return any leads p
26. ia dentro del 5 con alta estabilidad para asegurar que la frecuencia no se desplace El coraz n del generador de funciones es un VCG generador controlado por voltaje que produce ondas de seno cuadradas y triangulares precisas desde los 0 2Hz hasta 2 MHz para aplicaciones subaudibles de audio de ultrasonido y RF Un desplazamiento offset de DC de variaci n continua permite inyectar la se al directamente en circuitos con la polarizaci n correcta 18 La simetr a variable de la forma de salida convierte al instrumento en un generador de pulsos capaz de generar ondas rectangulares o pulsos ondas de rampa o diente de sierra y senoidales inclinadas Adem s de estas caracter sticas puede usar un voltaje externo para controlar la frecuencia de operaci n CARACTER STICAS DE FRECUENCIA Formas de onda seno cuadrada triangular pulso rampa Rango 0 2Hz a 2MHz en 7 rangos Precisi n del dial 5 Rango de sintonia 10 1 Ciclo de servicio variable 15 85 15 continuamente variable Modos de operaci n normal VCG CARACTER STICAS DE SALIDA Impederica 50 OHM 10 Nivel 20 V p p circuito abierto 10Vp p a 50Q Control de amplitud Variable 20db rango tipico Atenuaci n 20db 1db Compensaci n DC offset Preestablecido 0 1 V t pico Variable 10V circuito abierto 5V a 500 ESPECIFICACIONES ONDA SENOIDAL Distorsi n 3 a 1Khz t pica Aplanado 5 45dB ONDA CUADRADA S
27. idado al conectar la salida del generador de funciones a un punto receptor de sefiales Un voltaje excesivo del generador en el punto de inyecci n puede causar dafio interno Bajo operaci n normal la salida del generador nunca debe conectarse a un voltaje externo mayor que el que provee el control DC OFFSET El Modelo 4010A esta protegido contra sobrecargas asi que aunque se establezca un corto circuito continuo en la salida no sufrir dafios Se incluye un fusible en serie con el jack OUTPUT de salida para ayudar a proteger al instrumento contra dafios al conectarlo a un voltaje excesivo externo Da o de este tipo usualmente ocurre al conectar accidentalmente la salida del generador de funciones a un voltaje en el equipo bajo prueba Se recomiendan enf ticamente las siguientes medidas de protecci n 1 El usuario debe conocer el equipo bajo prueba lo suficiente bien para identificar los puntos correctos de inyecci n de se ales e g la base de un transistor una entrada l gica de una compuerta etc El voltaje en un punto de inyecci n de se ales v lido rara vez es suficientemente elevado para da ar al instrumento 2 Si duda sobre la seguridad de un punto de inyecci n de se ales mida el voltaje presente en dicho punto antes de conectarle la salida del generador de funciones 3 Cuando aplique la salida principal del generador de se ales a un punto de un circuito que contenga un nivel de DC ajuste el control DC OFFSET par
28. imetr a 0 2Hz a 100K Hz lt 2 Tiempo de elevaci n lt 120Ns ONDA TRIANGULAR Linealidad gt 98 a 100KHz 19 ESPECIFICACIONES SALIDA TTL FUENTE DE PODER Nivel 0 8V a 2 4V 120 230 VAC 10 50 60hz Selecci n por jumper interno Tiempo de elevaci n lt 20ns Ciclo de servicio 50 t pico DIMENSIONES SALIDA CMOS 26 7 x 11 4x 31 1 cm Nivel 4V a 14 0 5V PESO continuamente variable Tiempo de elevaci n lt 50ns 4 LB 1 845 kg ENTRADA DE VCG generador controlado por voltaje ACCESORIOS Voltaje de entrada Cable de salida BNC a clips de cocodrilo Manual de usuario 0 10V 1V causa un cambio de frecuencia 100 1 Impedancia 10K OHM 5 NOTA Las especificaciones y la informacion estan conforme a cambio sin el aviso de B amp K Precision Corp Por favor visite www bkprecision com para las especificaciones mas corriente y informacion de nuestros productos 20 CONTROLES E INDICADORES PANEL DELANTERO Vea la Fig 1 10 11 12 13 14 15 16 INTERRUPTOR DE ENCENDIDO POWER Enciende y apaga el instrumento SWITCH DE RANGO RANGE Selecciona el rango de la frecuencia de salida 7 rangos de 2Hz a 2MHz El switch indica la maxima frecuenta del rango y se ajusta con el control grueso de frecuencia a 0 1 veces el maximo Por ejemplo si el rango de 200kHz es seleccionado la salida de frecuencia puede ser ajustada de 20kHz a 200kHz SWITCH DE FUNCIONES FUNCTION Selecciona la forma de
29. luir todas las pr cticas aceptadas para prevenir descargas de alto voltaje y desviar la corriente lejos del coraz n en caso de contacto accidental con un alto voltaje Puede reducir el factor de riesgo significativamente si observa las siguientes medidas de seguridad 1 No se exponga a altos voltajes sin necesidad Remueva la caja y tapas solo cuando sea necesario Apague el equipo cuando haga conexiones de prueba en circuitos de alto voltaje Descargue los capacitores de alto voltaje despu s de apagar 2 Si es posible familiaricese usted mismo con el equipo por revisar y la localizaci n de los puntos de alto voltaje Considere sin embargo que un voltaje alto puede aparecer en puntos inesperados en equipo defectuoso 3 Use un piso de material aislante o un tapete aislante largo para situarse y una superficie de trabajo aislante en la cual pueda poner el equipo aseg rese que las superficies no est n h medas o mojadas 4 Use la probada t cnica de mantener una mano en la bolsa cuando este usando una sonda o punta de prueba del instrumento Evite con particular cuidado tocar un objeto met lico que pueda proveer un buen retorno a tierra 5 Cuando revise un equipo conectado a voltaje de AC recuerde que el voltaje est usualmente presente en algunos circuitos de entrada tal como el switch de encendido y apagado fusibles transformadores de poder etc mientras el equipo est enchufado a una toma de AC aun a n cuando est apagado
30. r otros derechos cuales cambian estado por estado B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 31 SEGURIDAD DEL INSTRUMENTO DE PRUEBA continuacion desde el 6 Ciertos equipos con cable de poder de 2 puntas incluyendo otros con cable polarizado son del tipo de chasis caliente Esto incluye la mayor a de los m s recientes receptores de televisi n y equipos de sonido Un gabinete de pl stico o de madera a sla el chasis para proteger al cliente Cuando el gabinete es removido para servicio un serio peligro de choque existe si se toca el chasis Adem s del peligro de choque el ctrico tanto el instrumento de prueba como el aparato bajo prueba pueden da arse al conectar la punta de tierra del instrumento al chasis caliente Para probar equipos con chasis caliente conecte siempre un transformador de aislamiento entre el enchufe de AC y el equipo bajo prueba El B 8 K Precision Modelo TR 110 o el transformador de aislamiento 1604 o bien las fuentes de poder de AC modelos 1643 o 1655 son adecuados para la mayor a de las aplicaciones Para mayor seguridad trate todos los equipos con cable de poder de 2 puntas como de chasis caliente a menos que est seguro que tiene un chasis aislado o un chasis a tierra 7 En instrumentos de prueba o cualquier equipo con cables de AC de 3 puntas con ctelos s lo a un enchufe que acepte las 3 puntas Esta es una caracter
31. recision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 Incluya con el instrumento la direcci n de vuelto para env o nombre del contacto n mero de tel fono y descripci n del problema 30 BK PRECISION y Garant a Limitada de Un Ano B amp K Precision Corp Autorizaciones al comprador original que su productos y componentes ser n libre de defectos por el periodo de un ano desde el d a en que se compro B amp K Precision Corp sin carga repararemos o sustituir a nuestra opci n producto defectivo o componentes Producto devuelto tiene que ser acompa ado con prueba de la fecha del la compra en la forma de un recibo de las ventas Para obtener cobertura en los EE UU este producto debe ser registrado por medio de la forma de registro en www bkprecision com dentro de quince 15 d as de la compra de este producto Exclusiones Esta garant a no se aplica en el evento de uso en error o abuso de este producto o el resultado de alteraciones desautorizado o reparaciones La garant a es vac a si se altera se desfigura o se quita el n mero de serie B amp K Precision Corp no ser obligado a dar servicio por danos consecuente incluyendo sin limitaciones a danos resultando en perdida de uso Algunos estados no permiten limitaciones de da os fortuitos o consecuentes Tan la limitaci n o la exclusi n antedicha puede no aplicarse a usted Esta garant a le da ciertos derechos y pueden tene
32. rned product must be accompanied by proof of the purchase date in the form of a sales receipt To obtain warranty coverage in the U S A this product must be registered by completing a warranty registration form on www bkprecision com within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed B amp K Precision Corp shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 18 TEST INSTRUMENT SAFETY continued from inside front cover 6 Some equipment with a two wire ac power cord including some with polarized power plugs is the hot chassis type This includes most recent television receivers and audio equipment A plastic or wooden cabinet insulates the chassis to protect the customer When the cabinet is removed for servicing a serious shock hazard exists if the chassis is touched Not only does this present a dangerous shock hazard but
33. robes connectors and accessories that you are using with the device Non Warranty Service Return the product in the original packaging to the address below Clearly state in writing the performance problem and return any leads probes connectors and accessories that you are using with the device Customers not on open account must include payment in the form of a money order or credit card For the most current repair charges please visit www bkprecision com and click on service repair Return all merchandise to B amp K Precision Corp with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North American is included for Warranty Service For overnight shipments and non North American shipping fees please contact B amp K Precision Corp B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 Include with the returned instrument your complete return shipping address contact name phone number and description of problem 17 BK PRECISION Limited Two Year Warranty B amp K Precision Corp warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of two years from date of purchase B amp K Precision Corp will without charge repair or replace at its option defective product or component parts Retu
34. siempre que el instrumento est conectado a un enchufe de AC aunque est apagado Siempre desenchufe el generador de funciones antes de efectuar procedimientos de servicio 28 REEMPLAZO DE FUSIBLES 1 Localice el sostenedor de fusible en la linea de entrada 2 Quite el sostenedor del fusible y dubstituya el fusible por un fusible de valor egual SERVICIO DE REPARACION DEL INSTRUMENTO Debido a las especializadas habilidades y equipo de prueba requerido para la reparaci n y calibraci n del instrumento muchos clientes prefieren depender en B amp K Precisi n para este servicio Nosotros mantenemos una red de agencias de servicio autorizadas para este prop sito Para usar este servicio a n si el instrumento ya no esta bajo garant a siga las instrucciones en la parte de INSTRUCCIONES DE SERVICIO DE GARANTIA de este manual Hay un cargo nominal por instrumentos fuera de garant a SOPORTE AL CLIENTE 1 800 462 9832 b k Precision ofrece soporte t cnico profesional y cort s antes y despu s de la venta de sus equipos de prueba Los siguientes son servicios tipicos de los disponibles de nuestro tel fono sin carga e Asesor a t cnica sobre el uso de su instrumento e Asesor a t cnica sobre aplicaciones especiales de su instrumento e Asesor a t cnica para escoger el mejor instrumento para una tarea espec fica e Informaci n sobre accesorios opcionales para su instrumento e Informaci n sobre servicios de reparaci n y re
35. tio 1 Select the desired frequency range and waveform 2 Set the starting frequency with the FREQUENCY control Apply a positive DC voltage to the VCG INPUT jack 9 to decrease the frequency A voltage from 0 to 10 V will cause the frequency to decrease by a factor of 100 if the FREQUENCY control is set at maximum CW rotation For example if the starting frequency is 200 kHz applying 10 V will change the output frequency to 2 kHz 13 3 To operate the function generator as a sweep generator apply a positive going ramp signal to the VCG INPUT jack As the ramp voltage increases the frequency decreases The rate of sweep can be adjusted by varying the frequency of the ramp signal 4 Specific frequencies can be selected by applying a fixed dc voltage to the VCG INPUT jack or the frequencies can be stepped by applying a stepped dc voltage 5 Do not apply more than 15 volts de or de ac peak to the VCG INPUT jack Inputs of more than 15 volts will not cause any further shift in the frequency and could cause damage to the generator OUTPUT PROTECTION CONSIDERATIONS Use care when connecting the function generator output to a signal injection point Excessive voltage at the point of signal injection of the function generator can cause internal damage Under normal operation the generator output should never be connected to an external voltage other than low dc values that can be matched with the DC OFFSET control The Model
36. tive or negative DC component to the output signal The DC component introduced is independent of the OUTPUT LEVEL control and can be varied by 10 volts open circuited or 5 volts into 50 Q The DC Offset does not affect the TTL CMOS output ey a jack The effect of DC OFFSET is shown in Fig 3 CONSIDERATIONS 1 Counterclockwise rotation of the FREQUENCY control decreases the output frequency to approximately one tenth of the maximum for the range selected 10 1 For example if the 20K range is selected and the FREQUENCY control is set to full counterclockwise dial setting of 2 the output frequency is approximately 2 kHz DC Offset 2 Clockwise rotation of the FREQUENCY control increases the output frequency At the fully clockwise setting dial setting of 2 0 the output frequency will be equal to the Figure 3 Use of DC OFFSET Control RANGE selection That is when the 20K range is selected and the dial is set to 2 0 the output will be 20 kHz When the dial is set to 1 0 the output frequency is one half 6 Remember that the output signal swing of the generator 3 eee i va Lr pe nn ne of the maximum for the range selected When the 20K BE RO ei range is selected and the dial is set to 1 0 the output will DC offset Clipping occurs slightly above these levels be 10 kHz Fig 3 illustrates the various operating conditions 4 encountered when using the DC offset If the desired output signal is large or if a