Home
Transformer Manual 88W Update_20052014
Contents
1. a m v j U MM i N l Z TRANSFORMER e 88 WATT LANDSCAPE LIGHTING TRANSFORMER MODEL NO TRF100088 C 88 WATT 12V AC LANDSCAPE LIGHTING TRANSFORMER FOR USE ON 120V CIRCUITS ONLY OUTDOOR RECEPTACLE SHOULD BE OF GFCI TYPE SUITABLE FOR USE WITH SUBMERSIBLE FIXTURES DO NOT repair or tamper with cord or plug DO NOT use extension cords DO NOT submerge the transformer in water DO NOT connect two or more transformers in parallel DO NOT use the transformer with a dimmer switch DO NOT install the transformer within 10 feet of a pool spa or fountain DO NOT mount the transformer upon combustible material DO NOT bury the connectors or cables in combustible materials such as wood chips bark dried leaves or at depth greater than 6 inches DO NOT exceed the maximum wattage of the transformer s terminal ONLY plug the transformer cord into a covered 120V AC Class A Type GFCI ground fault circuit interrupter receptacle with a hooded flush type cover plate marked WET LOCATION The ambient temperature range in which this transformer will operate is from 30 C to 40 5 C CAUTION ALWAYS DISCONNECT THE TRANSFORMER FROM THE ELECTRICAL OUTLET WHEN WORKING ON THE LIGHTING SYSTEM CALCULATION LIGHTING CAPACITY The 88W transformer has 88W circuits which powers up to 88W of light To determine the maximum number of fixtures that can be safely connected to this transformer add up the individual wattages of all the fix
2. e Check that fixtures are correctly installed on the cable and that there are no short circuits Make all repairs before operating the lighting system TROUBLE SHOOTING If the transformer does not work at night it may be caused by one following conditions e Make sure the transformer is connected into power receptacle Check the low voltage cable connection make sure it is well connected with the transformer e Check the wiring of the fixture connector Make sure the contact pins pierced the wire plastic insulation and touch the electric wire outside e Check the bulb If the bulb is broken replace with new bulb e Check and make sure the transformer is not overload Aus Designed and Imported by Luminiz Inc 27 Leading Rd Etobicoke ON M9V 4B7 Canada 416 494 6616 1 855 LUMINIZ www luminiz com LISTED il HE v i uU MM i N i TRANSFORMATEUR 88 WATT D ECLAIRAGE NO DE MODELE TRF100088 C 88 WATT 12V AC TRANSFORMATEUR D ECLAIRAGE POUR DES CIRCUITS DE 120 V SEULEMENT LE RECIPIENT EXTERIEUR DEVRAIT ETRE DU TYPE GFCI ADAPTE POUR UNE UTILISATION AVEC APPAREILS SUBMERSIBLE e NE PAS r parer ou modifier le cordon ou la fiche e NE PAS utiliser de rallonges e NE PAS immerger le transformateur dans l eau e NE PAS connecter plusieurs transformateurs en parall le e NE PAS utiliser le transformateur avec un gradateur de lumi re e NE PAS installer le transformateur moins que 10 pieds de distan
3. prise couverte de 120V AC avec couvercle marqu pour WET LOCATION 2 Percez des trous de 3 16 po 4 76 mm 3 Installez les ancrages C et les vis D en laissant suffisamment d espace pour accrocher le transforma teur sur les vis de l arri re du transformateur REMARQUE Ne pas fixer le transformateur au mur a ce moment Tout d abord connectez le cable a basse tension aux bornes du transformateur CONNECTER CORDON D ALIMENTATION A BASSE TENSION AU TRANSFORMATEUR e Pour la connexion de c ble 12 16 diviser une extr mit du c ble d environ 2 et enl ve d environ 3 4 17 19mm d isolant de chaque fil et doucement torsadez ensemble les brins Voir sch ma 2 La distance de c ble la puissance totale et l espacement des appareils affectent la puissance lumineuse de chaque appareil le long de la course Un c ble de calibre sup rieur comme de calibre 12 recommand pour tous courses permet des appareils de puissance sup rieure au d but de la course Veillez toujours utiliser le c ble requis pour la charge de puissance m me sur de petites s ries S il vous pla t se r f rer aux configurations d installation recommand e sur la table ci dessous Ne jamais d passer 88W pour une course SCH MA 2 S il vous plait assurez de serrer la vis de la connexion de sortie au fil pour viter un court circuit et surchauff e REMARQUE Utilisation du c ble de calibre correct est essentiel pour obtenir un b
4. transformateur de 120V une prise couverte GFCI et utiliser un couvercle en plastique noir pour couvrir la cellule photo lectrique assurez vous que la cellule photo lectrique ne re oit pas de lumi re Appuyez sur le bouton de r glage A assurez vous que la cellule est compl tement allumer et enti rement recouvert par le couvercle en plastique Retirez le couvercle en plastique noir et vos appareils d clairage seront ferm s automatiquement SCH MA 3 FONCTIONNEMENT DU SYSTEME D ECLAIRAGE E z After installing the transformer check carefully and turn on the electrical source Timer Control R glez la commande de la minuterie voir sch ma 4 il ii Vous pouvez choisir OFF ON AUTO 4H 6H ou 8H Ce de oe OFF Eteint lumi res ne s allument pas E ON Allumer lumi res restent allumer E hi z AUTO Lumi res s allument automatiquement lorsque la luminance environnante j F devient sombre as ay 4H Lumi res s allument automatiquement lorsque la luminance environnante devient sombre et apr s 4 heures les lumi res s teignent 6H Idem que ci dessus apr s 6 heures les lumi res s teignent 8H Idem que ci dessus apr s 8 heures les lumi res s teignent SCH MA 4 IMPORTANT Si les circuits cass ou voyages il peut y avoir probl me potentiel pour un feu D branchez imm diatement le transformateur de la prise lectrique et v rifiez les poi
5. ce d une piscine d un spa ou d une fontaine e NE PAS monter le transformateur sur un mat riau combustible NE PAS enterrer les connecteurs ou des c bles en mat riaux combustibles tels que des copeaux de bois l corce des feuilles s ch es ou une profondeur sup rieure 6 pouces NE PAS d passer la puissance maximale du terminal de s du transformateur BRANCHER le cordon du transformateur dans une prise couverte de 120V AC de type Classe A GFCI disjoncteur de d faut de la terre avec un plaque encapuchonn marqu WET LOCATION e La gamme de temp rature ambiante pour l op ration optimale du transformateur est de 30 C a 40 5 C 2 Le dispositif est un composant certifi d un syst me d clairage dont la ATTENTION DEBRANCHEZ TOUJOURS LE TRANSFORMATEUR DE LA PRISE ELECTRIQUE pertinence de la combinaison doit tre d termin e par UL ou autorit s LORSQUE VOUS TRAVAILLEZ SUR LE SYST ME D CLAIRAGE de contr le locales ayant juridiction CALCULER LA CAPACIT DE LECLAIRAGE Le transformateur 88W poss de des circuits de 88W qui alimente jusqu 88W de lumi re Pour d terminer le nombre maximal d appareils pouvant tre connect s en toute s curit ce transformateur additionner les puissances individuelles de tous les appareils La puissance totale de vos appareils ne doit pas d passer la capacit de production du transformateur 88W INSTRUCTIONS D ASSEMBLAGE 1 1 Choisissez un lieu pr s de la
6. mer into 120V covered GFCI outlet and use a black plastic cover to cover the photocell make sure the photo cell does not receive any light Press the setting button to A make sure the photocell is completely turn ON and completely covered by the plastic cover Remove the black plastic cover and your lighting fixtures will be shut off automatically DIAGRAM 3 OPERATING THE LIGHTING SYSTEM After installing the transformer check carefully and turn on the electrical source Timer Control Timer control See Diagram 4 T i You can choose OFF ON AUTO 4H 6H or 8H al ith or OFF Power OFF z E ON Power ON z AUTO Lights will be ON automatically when surrounding luminance turns j F dark AH Lights will be ON automatically when surrounding luminance turns dark and after 4 hours the lights will turn OFF 6H Lights will be ON automatically when surrounding luminance turns dark and after 6 hours the lights will turn OFF 8H Lights will be ON automatically when surrounding luminance turns dark and after 8 hours the lights will turn OFF DIAGRAM 4 IMPORTANT If the circuits break trips there may be potential problem for a fire Immediately unplug the transformer from the electrical outlet and check the following e Low voltage cable is correctly inserted in the cable ports at the bottom of the transformer e Check for overload or short circuit wires touching along the cable
7. nts suivants e Un c ble basse tension est correctement ins r dans les orifices de c bles au bas du transformateur e Rechercher une surcharge ou un court circuit fils touche le long du c ble e V rifiez que les appareils sont correctement install s sur le c ble et qu il n y a pas de court circuit Effectuer toutes les r parations avant de faire fonctionner le syst me d clairage GUIDE DE D PANNAGE Si le transformateur ne fonctionne pas la nuit elle peut tre caus e par une des conditions suivantes e Assurez vous que le transformateur est connect en prise d alimentation e V rifiez la connexion du c ble basse tension assurez vous qu il est bien connect avec le transformateur e V rifier le c blage de la connexion de fixation Assurez vous que les broches de contact perc l isolation en plastique de fil et touche le fil lectrique l ext rieur Contr lez l ampoule Si l ampoule est cass e remplacez la par une ampoule neuve e V rifiez et assurez vous que le transformateur n est pas surcharg e UL us Designed and Imported by Luminiz Inc 27 Leading Rd Etobicoke ON M9V 4B7 Canada 416 494 6616 1 855 LUMINIZ www luminiz com LISTED
8. on rendement de l clairage Pour l usage avec SPT 3 SPT 2W souterrain bas circuit d nergie c ble de type ext rieur Longueur 25 minimum ATTENTION UN INCENDIE EST POSSIBLE SI UN FIL EST LASSE SERREZ BIEN LES VIS DE SHORT RUN LOOPING CONNEXION 12VAC OUTPUT CONSEILS ADDITIONELS 1 Distribuez les luminaires aussi uniform ment que possible le long du c ble 2 Placez les appareils de puissance sup rieure plus pr s du transformateur et les appareils de puissance inf rieure plus loin du transformateur 3 Placez le premier appareil loigner d un minimum de 10 pieds du transformateur 4 Une autre m thode de connexion par cable appel Looping doit tre utilis pour maintenir la production uniforme de la lumi re e UL us Designed and Imported by Luminiz Inc 27 Leading Rd Etobicoke ON M9V 4B7 Canada 416 494 6616 1 855 LUMINIZ www luminiz com LISTED ce i Luminiz TRANSFORMATEUR 88 WATT D CLAIRAGE INSTALLATION DU C BLE SCH MA 3 1 Desserrez les vis du port de c ble au fond du transformateur 2 Enfilez les c bles pr d nud s dans les ports de c ble au fond du transformateur et poussez fermement Serrez les vis 3 Completez la disposition et tester le syst me avant d enterrer le c ble 4 Montez le transformateur au mur l aide des vis et dumod le indiqu s dans les instructions de montage REMARQUE Si vous voulez tester la cellule pendant la journ e brancher le
9. re a minimum of 10ft away the transformer 4 Another cable connection method called Looping should be used to maintain even light output The device is a certified component of a landscape lighting systems where the suitability of the combination shall be determined by UL or local inspection authorities having jurisdiction NOTE Do not attach the transformer to the wall at this time First connect the low voltage cable to the transformer terminals DIAGRAM 2 NOTE Using the correct gauge cable is essential for obtaining proper lighting performance For use with SPT 3 SPT 2W underground low energy circuit outdoor type cable Minimum 25 length SHORT RUN LOOPING 12VAC OUTPUT 12VAC OUTPUT NZ 3 Qu Designed and Imported by Luminiz Inc 27 Leading Rd Etobicoke ON M9V 4B7 Canada 416 494 6616 1 855 LUMINIZ www luminiz com LISTED ds v B U MM N l Z TRANSFORMER 88 WATT LANDSCAPE LIGHTING TRANSFORMER CABLE INSTALLATION DIAGRAM 3 1 Loosen the cable port screws at the bottom of the transformer 2 Thread the pre stripped cables into the cable ports in the bottom of transformer and push in firmly Tighten the screws securely 3 Complete layout and test the system before burying cable 4 Mount the transformer to the wall using screws and template shown in the assembly instructions NOTE If you want to test the photocell during the day plug the transfor
10. tures The total wattage of your fixtures must not exceed output capacity of the 88W transformer ASSEMBLY INSTRUCTION L 2 3 Select location near 120V AC covered outlet with cover plate marked for WET LOCATION Drill holes 3 16 in 4 76mm Install anchors C and screws D leaving enough space for the transformer to hang on the screws by means located on the back of the Transformer CONNECT LOW VOLTAGE CABLE TO TRANSFORMER For cable connection 12 16 split one end of cable approximately 2 and strip about 3 4 17 19mm of insulation off each wire and twist strands tightly See Diagram 2 Cable distance total wattage and spacing of fixtures affect the light output of each fixture along the run Higher gauge cable such as 12 gauge recommended for all runs allows for the higher wattage fixtures at the beginning of the run Always make sure to use the cable required for the wattage load even on short runs Please refer to the recommended installation configurations on below table Never exceed 88W for any run Please make sure to tighten the screw of the output connection with wire to prevent short circuit and overheat CAUTION FIRE IS POSSIBLE BY A LOOSE WIRE TIGHTEN CONNECTION SCREWS FIRMLY ADDITIONAL TIPS k 2 d Distribute the light fixtures as evenly as possible along the cable Position the higher wattage fixtures closer to the transformer and lower wattage fixture away from it Place the first fixtu