1. 8146979 8146953 OWNER S MANUAL T Naat FO 8146953 8146979 Please read and understand all instructions before use Retain this manual for future reference 8146979 8146953 INTRODUCTION This submersible pump is designed for use as a utility pump For use with clean or slightly turbid fresh water Not intended for use in salty briny water oil or corrosive fluids The oil less motor system does not require lubrication SPECIFICATIONS Model 8146953 8146979 Volts 110 120V 110 120V Hz 60 Hz 60 Hz Amperage 5 0 AMPS 5 5 AMPS HP 0 45 HP 0 33 HP Max head 26 5 ft 26 ft Discharge 1 1 2 1 1 4 Max flow rate 29 GPM 42 GPM Thermally protected heavy duty motor Stainless steel motor housing High capacity 1 discharge IMPORTANT SAFETY PRECAUTIONS WARNING Read and understand all instructions before using this tool Keep this manual for the safety warnings and precautions operating inspection and maintenance instructions When using this tool basic precautions should always be followed to reduce the risk of personal injury and or damage to the equipment WORK AREA 1 Keep your work area clean and well lit Cluttered and dark areas invite accidents 2 Keep children bystanders and visitors away from the work area Do not let them handle tools or extension cords No one should be in the work area if they are not wearing suitable protective equipment SER
2. NOT store in water When re using the pump please re read the instructions TROUBLESHOOTING Problem Possible causes Suggested solution Pump does not start Blown fuse circuit breaker has If fuse has blown replace with new fuse tripped reset circuit breaker Low line voltage Check size of wiring from main switch on property contact your local power authority Defective motor Contact Princess Auto at 1 800 665 8685 Pump operates but pumps very little or Low line voltage Check size of wiring from main switch on no water property contact your local power authority Debris caught in impeller Contact Princess Auto at 1 800 665 8685 Worn or defective parts Contact Princess Auto at 1 800 665 8685 Pump has stopped Lower than operating water level has Increase operating water level or pump caused pump to overheat cooler water PARTS IDENTIFICATION Discharge Outlet Pump Handle Pump Handle Discharge Outlet Motor Housing Sealed Intake Grill Keep clean Float Switch vase Intake Pump Base Keep clean Pump Base NOTE DO NOT OPEN THE MOTOR HOUSING For any technical questions please call 1 800 665 8685 4 8146979 8146953 MANUEL DU PROPRI TAIRE D vee ee 8146953 8146979 Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tar
3. VICE 1 Check for damaged parts Before using any tool any part that appears to be damaged should be carefully checked to determine that it will operate properly and perform its intended functions Check for alignment and binding of moving parts broken parts or mounting fixtures or any other condition that may affect proper operation Any part that is damaged should be properly repaired or replaced by a qualified technician 2 When servicing use only identical replacement parts Only use accessories intended for use with this tool Replace damaged parts immediately TOOL USE AND CARE 1 Use the right tool for the job Do not attempt to force a small tool or attachment to do the work of a larger industrial tool The tool will perform better and safer at the task for which it was intended Do not modify this tool or use for a purpose for which it was not designed For any technical questions please call 1 800 665 8685 2 8146979 8146953 ELECTRICAL SAFETY Disconnect power supply Disconnect from power supply when not in use before cleaning servicing or changing any parts or accessories Double Insulated pumps are equipped with a polarized plug one blade is wider than the other this plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install a polarized outlet Do not change the plug in any way Double Insulation
4. ans une prise de courant polaris e S il vous est impossible de l introduire compl tement tournez la l envers Si c est encore impossible de la brancher demandez un lectricien professionnel d installer une prise de courant polaris e Ne modifiez jamais la fiche elle m me L isolement double limine la n cessit d utiliser un cordon mis terre trois fils et un syst me d alimentation lectrique mis terre 3 Ne maltraitez pas le cordon d alimentation Ne vous en servez jamais pour transporter la pompe ou la d brancher Tenez le cordon l cart de la chaleur de l huile des bords tranchants et des pi ces mobiles de l outil Si le cordon est endommag il faut le remplacer imm diatement 4 Lorsque vous vous servez d une pompe l ext rieur employez un cordon prolongateur portant la mention W A ou W Ces rallonges peuvent tre utilis es l ext rieur et elles r duisent le risque de choc lectrique 5 vitez les cordons prolongateurs trop longs Choisissez un cordon appropri pour la t che que vous ex cutez Un cordon tr s long qui tra ne sur le plancher peut tre plus dangereux qu utile CONSIGNES PARTICULI RES DE S CURIT La pompe a t con ue pour tre utilis e avec de l eau douce propre ou l g rement trouble On ne doit pas s en servir avec de l eau sal e ou saumatre de l huile ou des liquides corrosifs 2 Ne soulevez jamais la pompe par son cordon d alimentation lectrique Soul
5. d 8146979 8146953 EA Pompe Submersible INTRODUCTION Cette pompe submersible a t mise au point pour servir de pompe utilitaire On doit l utiliser avec de l eau douce propre ou l g rement trouble Elle n a pas t congue pour tre employ e avec de l eau sal e ou saumatre de l huile ou des liquides corrosifs Son syst me moteur sans huile n exige aucune lubrification FICHE TECHNIQUE Mod le 8146953 8146979 Tension 110 120 volts 110 120 volts Fr quence 60 hertz 60 hertz Intensit 5 0 amp res 5 5 amp res Puissance 0 45 cheval vapeur 0 55 cheval vapeur D bit maximal 2000 gallons heure 2780 gallons heure Hauteur maximale 26 5 pieds 26 pieds Moteur protection thermique pour service intense Bo tier en acier inoxydable pour le moteur Sortie de 1 pouce haute capacit CONSIGNES IMPORTANTES DE S CURIT AVERTISSEMENT Vous devez lire attentivement toutes les instructions pour bien les comprendre avant de vous servir de cet outil Conservez ce manuel Gardez ce manuel dans un endroit s r pour pouvoir le consulter plus tard Lorsque vous utilisez cette pompe vous devez toujours respecter les pr cautions fondamentales AIRE DE TRAVAIL 4 Votre lieu de travail doit toujours tre propre et bien clair Des tablis encombr s et des zones obscures invitent les accidents 3 Quand vous utilisez cette pompe tenez les spectateurs les enfants et les visi
6. e discharge line shut off the power immediately The water level is likely very low and the pump is no longer primed The pump is designed to pump cool water only Pumping heated water or liquids other than water can overheat the motor Do not pump flammable liquids there is a risk of explosion Keep the pump inlet free of debris or foreign material at all times If required use a raised base for the pump to sit on see Installation 1 We also recommend using a pump bag or filter to extend the life of your pump For any technical questions please call 1 800 665 8685 3 8146979 8146953 MAINTENANCE amp STORAGE Always ensure that the pump is operating with adequate water supply Periodically shut off the power supply and check the pump for debris lodged in the intake grill The intake grill may be removed and cleaned by removing the screws underneath the pump housing The pump s motor is completely sealed in the motor housing and does not require regular service Disassembly of the motor housing or modification or removal of the power cords voids your warranty The power cord is non replaceable Make sure the pump is dry and clean before storing Retain the original packaging for the purpose of storing your pump Always store your pump in a cool dry place Never store it while it is still connected to power Do not stress the cord by wrapping it too tightly around the pump as it could cause the cord to eventually fray and break down DO
7. eliminates the need for a three wire grounded power cord and grounded power supply system Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use any adapter plugs Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded If the pump should electronically malfunction or break down grounding provides a low resistance path to carry electricity away from the user Do not abuse the cord Never use the cord to carry the pump or pull the plug from an outlet Keep cord away from heat oil sharp edges or moving parts Do not operate this pump if the power cord is frayed or damaged Replace damaged cords immediately Damaged cords increase the risk of electric shock Do not modify the plug in any way When operating outside use an outdoor extension cord marked W A or W These cords are rated for outdoor use and reduce the risk of electric shock Avoid using an unnecessarily long extension cord Choose a cord that is appropriate for the situation as a cord that is too long and running across the floor can be more dangerous than helpful SPECIFIC SAFETY INSTRUCTIONS pne The pump is designed for use with clean or slightly turbid fresh water Not intended for use in salty briny water oil or corrosive liquids Do not lift the pump by the power cord Attempti
8. evez toujours la pompe par sa poign e Quand vous devez descendre la pompe en place servez vous d un c ble attach la boucle qui se trouve au dessus de la poign e 3 D branchez la source d nergie rel chez toute la pression dans le syst me et vacuez l eau de la pompe avant de proc der son entretien 4 Avant de mettre la pompe en marche attachez bien la canalisation de sortie afin d viter les blessures corporelles et ou les dommages mat riels que pourrait entra ner un mouvement soudain de cette conduite 5 Avant d utiliser la pompe v rifiez chaque fois l appareil lui m me et ses tuyaux flexibles boyaux qui pourraient tre affaiblis ou trop us s puis assurez vous que tous les raccordements sont s curitaires 6 Examinez r guli rement la pompe et les l ments du syst me pour vous assurer qu il n y a pas de d bris et de corps trangers dans son orifice d aspiration N ouvrez jamais le carter de la pompe ni le bo tier de son moteur Pour viter tout risque de choc lectrique d branchez le courant avant de manipuler ou d inspecter la pompe 9 Cette pompe n a pas t con ue pour les piscines ou les zones marines N utilisez pas une pompe pour une t che pour laquelle elle n a pas t con ue INSTALLATION Mettez la pompe sur une surface dure et de niveau en vous assurant qu il n y a pas de d bris qui pourraient se loger dans son orifice d aspiration Au besoin servez vous d une planche ou d une p
9. laque de m tal si la surface de base est boueuse ou couverte de d bris Si vous avez des doutes au sujet des d bris dans l eau nous vous conseillons d utiliser un filtre ou un sac pompe vendu s par ment afin de prolonger la dur e de vie utile de votre appareil UTILISATION 14 La pompe doit tre submerg e dans au moins 1 pouce 30 cm d eau pour fonctionner Pour une utilisation ininterrompue une submersion compl te est pr f rable afin d emp cher le moteur de surchauffer 2 La pompe pourra retirer l eau jusqu 1 2 pouce 1 cm dans des conditions id ales Si la pompe tourne et qu il ne sort pas d eau de sa canalisation de refoulement coupez le courant imm diatement II est probable que le niveau de l eau soit trop bas et que la pompe soit alors d samorc e 3 La pompe n a t con ue que pour pomper de l eau assez froide Le pompage d une eau r chauff e ou d un liquide autre que l eau pourrait entra ner la surchauffe du moteur Ne pompez jamais un liquide inflammable car cela entra nerait un risque d explosion 4 L orifice d aspiration de la pompe doit toujours tre gard libre de d bris ou d autres corps trangers Au besoin utilisez une base sur lev e pour asseoir la pompe Voyez Installation 1 Nous vous conseillons aussi d employer un filtre ou un sac pompe pour prolonger la dur e de vie utile de votre pompe ENTRETIEN ET ENTREPOSAGE Assurez vous toujours que la pompe fonctionne avec un approvisio
10. ng to lift or support the pump by the power cord will damage the cord and cord connections Lift the pump by the handle only If you need to lower the pump into position use a rope attached to the loop provided above the handle Disconnect the power source release all pressure within the system and drain water from the pump before maintenance Check pump and hoses for weakened or worn condition before each use and make certain that all connections are secure Periodically inspect the pump and system components to make sure the inlet is free of debris or foreign objects Do not open the pump casing or motor housing Disconnect power before handling or inspecting the pump to remove the risk of electric shock This pump has not been designed for use in swimming pools or marine areas INSTALLATION Place the pump on a hard level surface making sure there is no debris that may lodge in the pump inlet Use a board or piece of metal if needed to raise the pump in the case of a muddy or debris covered base If you have doubts as to debris in the water we recommend using a pump filter or pump bag sold separately to extend the life of your pump OPERATION The pump must be submersed in at least 1 ft 30 cm of water to operate For continuous operation complete submersion is preferable to prevent the motor from overheating The pump will remove water down to 1 2 1 0 cm in ideal conditions If the pump is operating and no water comes out of th
11. nnement d eau suffisant Coupez p riodiquement l alimentation lectrique et examinez la pompe pour voir s il y a des d bris dans la grille d entr e On peut enlever et nettoyer cette grille en tant les vis qui se trouvent sous le carter de la pompe Le moteur de la pompe qui est compl tement scell dans son bo tier n exige pas d entretien r gulier Votre garantie est annul e si Pm Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 3 8146979 8146953 vous d montez le bo tier du moteur ou si vous tentez de modifier ou d enlever le cordon d alimentation lectrique Ce cordon n est pas rempla able Avant de ranger la pompe assurez vous qu elle est s che et propre Conservez l emballage d origine pour entreposer votre pompe Entreposez toujours votre pompe dans un endroit sec et frais Vous ne devez jamais l entreposer alors que son cordon est encore branch N tirez pas ce cordon en l enroulant trop serr autour de la pompe car cela pourrait l endommager la longue La pompe NE doit PAS tre laiss e dans l eau Avant de remettre la pompe en service n oubliez pas de relire les instructions Sympt mes Causes possibles Solutions propos es La pompe ne d marre pas Fusible saut ou Remplacez le fusible saut ou r enclenchez disjoncteur d clench le disjoncteur Faible tension du secteur V rifiez la grosseur du c blage partir de l interrupteur principal sur la propri t o
12. teurs une distance prudente Ne les laissez pas manipuler des rallonges SOIN ET UTILISATION DE L OUTIL 4 Ne forcez pas la pompe Choisissez une pompe appropri e pour la t che effectuer Avec la pompe appropri e on peu achever le travail d une mani re plus efficace et plus s curitaire N utilisez pas une petite pompe quand la t che n cessite un mod le industriel plus gros Ne modifiez pas cet outil et ne l utilisez pas pour des t ches pour lesquelles il n a pas t con u ENTRETIEN 1 Examinez bien la pompe chaque fois avant de vous en servir Ne l utilisez pas si vous d couvrez une pi ce deserr e coing e d salign e ou endommag e Si vous d couvrez quoi que ce soit d anormal faites r parer la pompe avant de vous en servir 2 Pour r parer la pompe il faut utiliser uniquement des pi ces de rechange identiques Employez seulement des pi ce autoris es Suivez les conseils donn s dans la section sur l entretien que vous trouverez dans ce manuel Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 2 8146979 8146953 S CURIT QUAND L LECTRICIT D branchez l alimentation d lectricit D branchez la pompe quand elle n est pas utilis e avant de la nettoyer ou pour changer un accessoire ou une pi ce 2 Les cordons double isolation sont munis d une fiche polaris e dont une lame est plus large que l autre Cette fiche ne peut tre introduite que d une seule fa on d
13. u communiquez avec la compagnie d lectricit Moteur d fectueux Contactez Princess Auto au 1 800 665 8685 La pompe marche mais Faible tension du secteur V rifiez la grosseur du c blage a partir elle pompe tr s peu d eau de l interrupteur principal sur la propri t ou pas du tout ou communiquez avec la compagnie d lectricit D bris pris dans la turbine Contactez Princess Auto au 1 800 665 8685 Pi ces us es ou d fectueuses Contactez Princess Auto au 1 800 665 8685 La pompe s est arr t e Le niveau d eau tant trop bas Augmentez le niveau de l eau ou pompez de la pompe a surchauff l eau plus froide IDENTIFICATION DES PI CES Sortie de l eau Poign e de la pompe Poign e de la pompe Sortie de l eau Bo tier du moteur Grille scell d entr e garder Interrupteur flotteur propre 5 Entr e Base de la pompe a garder propre Base de la pompe N B N ouvrez jamais le bo tier du moteur Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 4

Download Pdf Manuals

image

Related Search

Related Contents

OSR 2014 cat 3    指紋認証装置及びカラープリンタ機器一式 仕様書 千葉市総務局情報  マル:722L495 要求No.3835 e  operation, service, and repair manual for tsurumi ept3  Nady Systems Microphone rsm-2 User's Manual  View Only Manual OpenEyes  User`s Manual - EPS Bio Technology Corp.  Dimanche 05 juillet - 9-9bis  Trust Vibration Feedback Steering Wheel GM-3400 & Test Drive Unlimited  