Home
Manuel - Automatisme Intensive
Contents
1. Check the wiring connection of the batteries The gate doesn t move when pressing the button of the transmitter 1 Check if LED3 or 4 is ON 2 Check if the voltage of the batteries is below 22V 3 Check if LED1 is ON 4 Make sure all the wiring connections are firmly connected to the terminals on the PCB 5 Make sure the fuse is workable The gate only moves a little distance when pressing the button of the transmitter Make sure the wiring connection of the hall sensor is firm The transmitting distance is too short Make sure the connecting terminals of the Antenna is firm The gear motors run very slowly Check the dip switch setting of the speed adjustment The Flashing light does not work The leaves shall be closed instead of opening The leaves suddenly stop during moving Check if the wiring connection of the flashing light is correct Change the polarity connection of the positive with the negative of the gear motors 1 Check if the RESET socket is activated 2 Make sure the wiring connection of the gear motors is firm 3 Make sure the hall sensor wiring connection is firm 4 The GND terminal of the photocells on the PCB must be short circuited if no photocells installed 5 Make sure the fuse is workable The leaves does not move or only move toward one direction The master gate closes to the
2. PS lt 5 N RF Indicator Ee o 9 9 A A A J Feu G che Moteur Moteur S lecteur Bouton clignotant 1 2 cl poussoir B 2 INSTALLATION O ER 5 5 S 5 2066660 LATS Mie Mi MIO Ma ao Sean 8 2 8 2 1 SW1 MODES DE FONCTIONNEMENT 2 1 1 Mode de ralentissement Dip 1 ON Le moteur ne d marre pas doucement et ne ralentit pas en fin de course OFF Le moteur d marre doucement et ralentit en fin de course Avant d alimenter la carte lectronique veuillez r gler vos clips switch en fonction du mode de fonctionnement d sir Paragraphe 2 1 jusqu a paragraphe 2 4 123 4 5678 123 4 5678 Ea BEE EE 00001000 1 NC 5 Latch 2 NC 6 Slow 3 NC 7 Fast 4 NC 8 Ds Set 1 S F Set 5Auto2 2 Over2 6 Auto1 3 Over1 7 Photo 4 Autos 8 Light NC Non utilis 2 1 2 R glage de puissance Dip 2 Over2 amp Dip 3 Over1 OVER1 Dip Switch 3 OFF OVER2 Dip Switch 2 OFF Intensite Amp 2A Dip Switch 3 ON Dip Switch 2 OFF 3A Dip Switch 3 OFF Dip Switch 3 ON Dip Switch 2 ON Dip Switch 2 ON 4A 5A 2 1 3 Mode fermeture automatique Dip 4 Auto 3 Dip 5 Auto 2 amp Dip 6 Auto 1 Auto ferme 1 Dip switch 6 OFF Auto ferme 2 Dip Switch 5 OFF
3. Auto ferme 3 Dip Switch 4 OFF Effect Pas de fermeture automatique Dip switch 6 ON Dip Switch 5 OFF Dip Switch 4 OFF 3 sec Dip switch 6 OFF Dip Switch 5 ON Dip Switch 4 OFF 10 sec Dip switch 6 ON Dip Switch 5 ON Dip Switch 4 OFF 20 sec Dip switch 6 OFF Dip Switch 5 OFF Dip Switch 4 ON 40 sec Dip switch 6 ON Dip Switch 5 OFF Dip Switch 4 ON 60 sec Dip switch 6 OFF Dip Switch 5 ON Dip Switch 4 ON 120 sec Dip switch 6 ON Dip Switch 5 ON Dip Switch 4 ON 300 sec En mode fermeture automatique quand votre portail est compl tement ouvert le fait d appuyer sur la t l commande ou le s lecteur cl fait que votre portail se refermera imm diatement en oubliant le temps de pause programm 2 1 4 Photocellules Dip 7 Photo ON En cas de rencontre avec un obstacle lors de la phase d ouverture le portail s arr tera ou arr t et inversion lors de la phase de fermeture OFF Le portail continue bouger lorsqu il rencontre des obstacles durant les phases d ouverture et de fermeture 2 1 5 Feu clignotant avec antenne int gr e Dip 8 Light ON Le feu clignotant clignote 3 secondes avant le mouvement du portail et clignote pendant le mouvement OFF Le feu clignote en m me temps que le d marrage du portail 2 2 SW2 MODES DE FONCTIONNEMENT 2 2 1 Gache lectrique Dip 5 Latch Les switchs 1 a 4 ne sont pas ut
4. Dip Switch 4 OFF 10 sec Dip switch 6 ON Dip Switch 5 ON Dip Switch 4 OFF 20 sec Dip switch 6 OFF Dip Switch 5 OFF Dip Switch 4 ON 40 sec Dip switch 6 ON Dip Switch 5 OFF Dip Switch 4 ON 60 sec Dip switch 6 OFF Dip Switch 5 ON Dip Switch 4 ON 120 sec Dip switch 6 ON Dip Switch 5 ON Dip Switch 4 ON 300 sec Note Auto close mode activates when the gates move to the end position or stopped manually If the transmitter push button or the key selector is activated before the auto close counting the gate will close immediately 2 1 4 Photocells Adjustment Dip 7 Photo ON When encountering any obstacles the gates will stop during opening phase stop and reverse during closing phase OFF The gate will keep moving when encountering any obstacles during closing and opening phases 2 1 5 Flashing Light Adjustment Dip 8 Light ON The flashing light blinks for 3 seconds before the gate moves and blinks simultaneously during the movement OFF The flashing light blinks and the gate moves simultaneously 2 2 SW2 Dip Switch Setting 2 2 1 Electric Latch Adjustment Dip 5 Latch ON The electric latch functions when dip switch is set to ON OFF The electric latch does not function when dip switch is set to OFF 2 2 2 Slowdown Speed Adjustment of The Gear Motors Dip 6 Slow ON The speed is 70 output of the full speed OFF The speed is 5
5. Note En cas de coupure de courant il n est pas utile de refaire une programmation Le d calage entre le d part des 2 vantaux l ouverture et la fermeture est de 3 secondes 2 6 Fonctionnement activation du portail Appuyez sur le bouton A de la t l commande pour faire fonctionner a les deux vantaux Pressez le bouton B de la t l commande pour faire fonctionner c D le passage pi ton 2 7 Logique du mouvement A Dans la phase d ouverture Le portail s arr te si le bouton t l commande s lecteur cl est activ et ferme lorsque le bouton t l commande s lecteur cl est r activ B Dans la phase de fermeture Le portail s arr te si le bouton t l commande s lecteur cl est activ et ouvre lorsque le bouton t l commande s lecteur cl est r activ C Dans la phase d ouverture ou de fermeture Pour la raison de s curit la portail s arr te en cas de rencontre avec un obstacle Situation 1 ASk Bouton A de t l commande pour l op ration d un vantail DkB Bouton B de telecommande pour l operation de deux vantaux Situation 2 BSk Bouton B de t l commande pour l op ration d un vantail DkA Bouton A de t l commande pour l op ration de deux vantaux Situation 3 CSk Bouton C de t l commande pour l op ration d un vantail DkD Bouton D de t l commande pour l op ration de deux vantaux Situation 4 DSk Bouton D de t l comman
6. Latch Connect the two wires from the electric latch to the terminal LAT and LAT on the PCB 3 Gate openers Refer to Figure 1 4 and connect the wires separately to the terminals on the PCB M1 Connect the motor wire White to the terminals M1 and Yellow to the M1 Connect the hall sensor wires red green and black to the terminals 5V S1 and GND M2 Connect the motor wire White to the terminals M2 and Yellow to the M2 Connect the hall sensor wires red green and black to the terminals 5V S2 and GND Notes For gates opened outward M1 Connect the motor wire Yellow to the terminals M1 and White to the terminals M1 M2 Connect the motor wire Yellow to the terminals M2 and White to the terminals M2 4 PH 1 Photocells See Figure 1 4 A In the installation of one set Connect the wires referred to 7 and 9 And remove the electric jumper JP1 B In the installation of two sets connect the wires referred to 7 8 9 and 10 And remove both the electric jumper JP2 and JP1 Figure 1 4 Antenna Figure 1 4 Transformer J2 12345678 12345678 BAT BAT 24V RF learn SYS learn 10 20 E EIRE 5 01 5 E E pn 02 a 0 Q 0 Key Selector Pus
7. MON paie nn ata a NEL k s Teles cica ceea gi dac aaa SG Esi ca aaa aa atac atata eaten 9 19 EE ucenic a cota Vata E cei ae Rues de ad adabd RM adabd ada eta Reference produit R f rence Qt Sous total TELECOMMANDE INTENSIVE 3760074139910 25 80 x LOT 2 PHOTOCELLULES INTENSIVE 3760074139606 27 80 x SELECTEUR A CLES 3760074132355 24 40 x CLAVIER CODE XO 006A 3760074130085 32 40 x GACHE APPLIQUE XO 201 3760074130146 30 50 x SERRURE ELECTRIQUE XO 404 3760074131198 42 50 x RADIOCOMMANDE UNIVERSELLE INTENSIVE 3760074139927 56 80 x PANNEAU SOLAIRE 12 24V 3760074131303 141 10 x FRAIS DE PORT montant 1 produit 7 12 ad ol ae la tae total produit 2 3 produits 9 50 livraison r f rez vous au frais de port 4 10 produits 11 90 tableau ci dessus TOTAL 10 produits 17 90 Les frais de livraison sont exclusivement valables pour la France m tropolitaine 0 paiement par ch que Prix valables jusqu au 1 janvier 2015 DECLARATION DE GARANTIE A RENVOYER aupr s de votre installateur ou distributeur VOTRE PRODUIT LR EN I nom kit automatisme pour portail battants INTENSIVE4 code barre num ro 13 chiffres iii N lot indiqu dans la zone du code barre du PACKAGING mmm anna LIEU D ACHAT a aa da Aaaa aia al VOUS LELE E PEE
8. after the master gate opens and the master gate closes 3 seconds after the slave gate closes 2 6 Gate Operation Press the button A on the transmitter for dual gate operation Press the button B on the transmitter for single gate operation in either single gate or dual gate installation 2 7 Gate moving Logic A In gate opening phase The gates stop if the transmitter push button key selector is activated and close when the transmitter push button key selector is reactivated B In gate closing phase The gates stop if the transmitter push button key selector is activated and open when the transmitter push button key selector is reactivated C In gate opening or gate closing phase For safety purpose the gates stop if encountering obstacles 2 8 Advanced Operation of the Transmitter a 8 OJO Situation 2 BSk Transmitter button B for single leaf operation DkA Transmitter button A for double leaves operation Situation 3 CSk Transmitter button C for single leaf operation DkD Transmitter button D for double leaves operation See the following description 9 69 o se s 3 TROUBLE SHOOTING Overheated Back up Batteries Situation 1 ASk Transmitter button A for single leaf operation DkB Transmitter button B for double leaves operation Situation 4 DSk Transmitter button D for single leaf operation DkC Transmitter button C for double leaves operation
9. end first and the slave gate stops the flashing light blinks fast for five seconds 1 Check if the RESET socket is activated 2 Make sure the wiring connection of the gear motors is firm 3 Make sure the hall sensor wiring connection is firm 4 The GND terminal of the photocells on the PCB must be short circuited if no photocells installed Cut off the AC input power and the output of the batteries Release the master gate and slave gate manually then open the master to the end and close the slave gate to the end by hand then power the whole unit by connecting the AC and battery terminals The gear motors does not run and the relay is noisy when operating the gate opening and closing Check if the fuse is burned
10. the motor Make sure the White bar on the knob is on the position opposite to the triangle indication To restore the automation simply reverse the above procedure 1 3 TECHNICAL FEATURES Motor 24Vdc motor with mechanical release Type Worm gear Max Absorbed Power 144W Peak Thrust 3000N Nominal Thrust 3000N Stroke Length 300mm Power Supply 24Vdc Nominal Input Power 2A Maximum Operating Current Maximum Gate Weight Maximum Gate Length Duty Cycle Operating Temperature Dimension Weight 5 5A for maximum 10 seconds 300 kg per leaf 3 meters 20 20 C 50 C 837mm x 123mm x 124mm 1 4 Maintenance Conduct the following operations at least every 6 months If in high intensity of use shorten the period in between Disconnect the power supply 1 Clean and lubricate the screws the pins and the hinge with grease 2 Check the fastening points are properly tightened 3 Make the wire connection are in good condition Connect the power supply 1 Check the power adjustments 2 Check the function of the manual release 3 Check the function of photocells or other safety devise BON DE COMMANDE A RETOURNER PAR COURRIER A Syst me de Communication et de S curit SA service commande Rte de St Symphorien BP 69 85130 Les Landes g nusson FRANCE MES COORDONNEES ERIS op te SIREN eee catel NOM ann a e at ann a ta e oda PRE
11. 0 output of the full speed 2 2 3 Operation Speed Adjustment of The Gear Motors Dip 7 Fast ON The speed is 100 output of the full speed OFF The speed is 80 output of the full speed 2 2 4 Single and Dual Gate Operation Adjustment Dip 8 Ds Set ON Dual Gates operation in system learning and normal operation OFF Single Gate operation in system learning and normal operation 2 3 LED Indication LED1 System Learning LED1 blinks once when single gate learning is completed LED1 blinks twice when dual gate learning is completed LED2 RF If the switch of the transmitter key selector or the push button is activated LED2 will be on LED3 Photocells 1 LED3 will be on when the first pair of the photocells are activated LED4 Photocells 2 LED4 will be on when the second pair of the photocells are activated LED5 RF Indicator LED5 will be on when RF signal is received mac Switch r LED1 H SYSlearn i B Hl LED2 ml RFLED HE Dre ro LED3 ae rio dara Le Ea tz AED IEEE atat OKEY SKEY GND Phot VOC la RS Ph01 LED4 E Pno2 LED5 m RFlearn 2 4 Transmitter Memorizing and Erasing Process A Transmitter Memorizing Press and hold the S3 button on the PCB for 1 second and then the blue LED indicator on the RF board will be ON Press A button for dual gate installation press B button for single gate installation on the transmitter within 5 seconds The transmitter learning
12. 7 Photo 2 1 5 FEU CLIGNOTANT AVEC ANTENNE INTEGREE Dip 8 Light 2 2 SW2 MODES DE FONCTIONNEMENT 2 2 1 G CHE LECTRIQUE Dip 5 Latch 2 2 2 R GLAGE DU MOTEUR RALENTISSEMENT Dip 6 Slow 2 2 3 R GLAGE DU MOTEUR VITESSE Dip 7 Fast 2 24 FONCTIONNEMENT DU PORTAIL SIMPLE ET DOUBLE Dip 8 Ds Set 2 3 INDICATION DE LED 24 M MORISATION ET L EFFACEMENT DE T L COMMANDE 2 5 PROCESSUS D APPRENTISSAGE DU SYST ME 2 6 FONCTIONNEMENT ACTIVATION DU PORTAIL 2 7 LOGIQUE DE MOUVEMENT 2 8 L UTILISATION AVANC E DE T L COMMANDE 3 MAINTENANCE ET DIAGNOSTIC DE PANNES OJ JOJO JOI BIB I BI BIBIBIB IB JOJO 1 BOITIER DE CONTROLE INSTALLATION 1 Decidez de la position d installation de votre coffret De preference sur l un des deux piliers du portail et a l abri de dommages ventuels 2 D vissez le couvercle Sch ma 1 1 3 Utilisez un tournevis pour percer les passages de c bles Sch ma 1 2 4 Fixez le bo tier au mur Sch ma 1 3 Attention la carte de commande l int rieur veillez ne pas l endommager Figure 1 1 Figure 1 3 5 Raccordement des l ments Pr parez tous les fils des accessoires l avance connectez les fils aux moteurs et les accessoires sur les borniers de raccordement Sch ma 1 4 page suivante Toutes les accessoires ne sont pas obligatoires bien respecter les polarit s et 1 Feu clignotant Connectez les deux fils du feu a LIT et LIT sur le bo
13. ER iai mt ai aaa at cea z az a mm Manueli d INSTANATION ET d UTHISATION INTEeNSIVEeA KIT AUTOMATISME PO Technologie pour portail a battants par encodage TABLE DES MATIERES 1 1 PRECAUTIONS POUR L INSTALLATEUR P 1 1 2 INSTALLATION P 2 A Installation de l automatisme P 2 B Tableau de dimensions P 2 C Fixation du moteur P 3 D Raccordement du ee nls eal Peas Ae a ee ie P 3 E Deverrouillage d urgence P4 1 3 CARACT RISTIQUES TECHNIQUES P 4 1 4 MAINTENANCE P 5 1 1 PRECAUTIONS POUR L INSTALLATEUR ATTENTION Ce manuel est uniquement destin aux techniciens qualifi s sp cialis s dans les installations d automatismes de portail 1 Toutes les installations les branchements lectriques les ajustements et les tests ne doivent tre effectu s qu apr s une lecture attentive et une bonne compr hension des instructions 2 Avant de commencer toute op ration d installation ou d entretien d branchez l alimentation lectrique 3 Assurez vous que la structure existante est conforme aux normes en termes de r sistance et de stabilit 4 Si n cessaire raccorder le portail
14. NE te dea a aaa ata lt lt ouale da OM E E DI NOMA N oubliez pas d enregistrer votre garantie dans le mois suivant votre achat Conservez soigneusement votre justificatif d achat il vous sera demand pour faire jouer la garantie WARRANTY DECLARATION TO RETURN BY MAIL TO your installer or distributor YOUR PRODUCT AZI ANS product name automation kit for swing gates INTENSIVE4 gencod MS NUMOS batch number close to gencod location inserer PURCHASE LOCATION COMPANY i esisiini iieri oaia date Of PUIENOSC i CIV 7 LID 6606 sans iati ata da atata ata dat au YOU COMPANY Re dau again alai a Res NAME 15 RER E a SUMMAM iza dl Rent ONONE EME i zici sosi ciot Nain CITY acc sosului oana E a ndesat ti d d LID COOS E DODI II SR ERORI To be send atleast 1 month after purchasing Please keep your proof of purchase pour tout probleme technique veuillez contacter votre installateur ou distributeur INTENSIVE BO TIER DE CONTR LE Index 1 BO TIER DE CONTR LE 2 INSTALLATION 2 1 SW1 MODES DE FONCTIONNEMENT 2 1 1 MODE RALENTISSEMENT Dip 1 S F Set 2 1 2 SURINTENSITE Dip 2 Over2 amp Dip 3 Over1 2 1 3 MODE FERMETURE AUTOMATIQUE Dip 4 Auto 3 Dip 5 Auto 2 amp Dip 6 Auto 1 2 14 PHOTOCELLULES Dip
15. bouton droite pour lib rer le moteur Assurez vous que la barre blanche sur le bouton soit sur la position oppos e l indication 1 3 CARACT RISTIQUES TECHNIQUES Moteur Moteur 24Vdc avec d verrouillage Type Motor ducteur Max puissance W 144W Force de pouss e 3000N Force de pouss e nominal 3000N Course 300mm Moteur lectrique 24Vdc Electrique nominal 2A Intensit 5 5A pour max 10 seconds Poids max vantail 300 kg Largeur max vantail 3 meters Intermittence travail 20 Temp rature de fonctionnement 20 C 50 C Dimensions 837mm x 123mm x 124mm Poids 1 4 MAINTENANCE Effectuer les op rations suivantes au moins tous les 6 mois En cas d utilisation fr quente raccourcir ce d lai Couper l alimentation 1 Nettoyer et graisser les vis les chevilles et la charni re 2 V rifier que les points de fixation soient bien serr es 3 V rifier la bonne connexion des c bles Connecter l alimentation 1 V rifier les r glages de l alimentation 2 V rifier le fonctionnement du d verrouillage manuel 3 V rifier le bon fonctionnement des photocellules ou autre dispositif de s ret An Installatior IN TENSIVETRA AUTOMATION KIT av eee for swing gates lt system Safety kit gt Control unit 2 remote contro VA le Id Blinker 1 1 General Safety Precaution P 1 1 2 Installation sa a
16. de pour l op ration d un vantail DkC Bouton C de t l commande pour l op ration de deux vantaux C k Les batteries de secours surchauffent 2 8 L utilisation avanc e de telecommande 3 Maintenance et diagnostic de pannes Verifiez la connexion du fil des batteries Le portail ne bouge pas lorsque vous appuyez sur le bouton de t l commande 1 Verifiez si le LED 3 ou 4 est allume 2 Verifiez si la tension de la batterie est inf rieure a 22V 3 Verifiez si le LED 1 est allum 4 Verifiez si tous les elements sont bien connect s 5 Verifiez si le fusible F1 est bon Le portail ne bouge que l g rement lorsque vous appuyez sur le bouton de la t l commande Assurez vous que le raccordement des fils de l encodeur sont bien effectu La distance de transmission est trop courte Assurez vous que le fil d antenne soit bien raccod Le vis sans fin marche tr s lentement V rifiez l ajustement de la vitesse avec les switchs La feu clignotant ne fonctionne pas Assurez vous que le raccordement du fil avec le feu est correcte Le portail se ferme au lieu de s ouvrir Inversez la polarit de votre vis sans fin de la borne positive a la borne n gative Le portail stoppe brusquement lors d une ouverture ou fermeture 1 V rifiez si RESET est active 2 Assurez vous du bon raccordem
17. e sur la touche S3 RF Learn le voyant LED 5 s allume en bleu appuyez sur la touche A de votre t l commande pendant 1 seconde l ouverture totale de votre motorisation est programm e puis appuyez 5 secondes sur la touche B de votre t l commande le passage pieton de votre motorisation est programm B Pour effacer toutes vos t l commandes maintenez la touche S3 RF Learn pendant 3 secondes C Le r cepteur radio peut m moriser 200 t l commandes maximum 2 5 Processus d apprentissage de la course du portail tape 1 positionnez vos deux vantaux compl tement ouvert en les d brayant l aide de la cl de d brayage et r embrayez les tape 2 Appuyez et maintenez pendant 5 secondes le bouton S2 SYS Learn le voyant LED 1 clignote une fois par seconde Munissez vous de l une de vos t l commandes d j programm e et appuyez sur la touche A pour lancer la programmation de vos deux vantaux ou sur la touche B pour lancer la programmation de votre passage pi ton Les tapes suivantes vont se d rouler Touche A le moteur M2 se ferme moteur M1 se ferme moteur M1 s ouvre moteur M2 s ouvre moteur M2 se ferme moteur M1 se ferme la programmation est termin e Quand la programmation est termin e le voyant LED 1 clignote 2 fois par seconde Touche B le moteur M1 se ferme le moteur M1 s ouvre puis se referme Quand la programmation est termin e le voyant DL1 clignote 1 fois par seconde
18. ent des moteurs 3 Assurez vous du bon raccordement de l encodeur 4 La borne GND des photocellules sur la carte doit tre court circuit e si aucune photocellule est install e 5 V rifiez si le fusible est normal Les vantaux ne bougent pas ou que dans une seule direction 1 V rifiez si RESET est activ 2 Assurez vous du bon raccordement des moteurs 3 Assurez vous du bon raccordement de l encodeur 4 La borne GND des photocellules sur le PCBA doit tre court circuit e si aucune photocellule est install e Le vantail ma tre se ferme enti rement et le vantail secondaire s arr te le feu clignote rapidement pendant 5 secondes Coupez l alimentation principale D verrouillez les 2 vantaux fermez les compl tement puis remettez l alimentation principale et relancez un cycle Les moteurs ne fonctionnent pas et le relais est bruyant pendant l ouverture et fermeture du portail V rifiez si le fusible F1 est br l INTENSIVE CONTROL BOX Index 1 Control Box 2 Setting 2 1 SW1 Dip Switch Setting 2 1 1 Slowdown Adjustment Dip 1 S F Set 2 1 2 Over current Adjustment Dip 2 Over2 amp Dip 3 Over1 2 1 3 Gate Auto close Adjustment Dip 4 Auto 3 Dip 5 Auto 2 amp Dip 6 Auto 1 2 1 4 Photocells Adjustment Dip 7 Photo 2 1 5 Flashing Light Adjustment Dip 8 Light 2 2 SW2 Dip Switch Setting 2 2 1 Electric Latch Adjustment Dip 5 Latch 2 2 2 Slowdown Speed Ad
19. h Button M2 2 SETTING s s s s 5 5 ad 5 0000002 UT LATE LAT Me Mi MIO Ma ss Sau 8 2 1 SW1 Dip Switch Setting 2 1 1 Slowdown Adjustment Dip 1 S F Set Before powering on the control unit the following dip switch setting must be decided by gate weight and installation environment first See Figure 2 NC No Connection 123 4 5678 123 4 5678 000 00 E i 1 NC 5 Latch 2 NC 6 Slow 3 NC 7 Fast 4 NC 8 Ds Set ON The gear motors do not slow down before the gates completely close or open OFF The gear motors slow down before the gates completely close or open 2 1 2 Over current Adjustment Dip 2 Over2 amp Dip 3 Over1 OVER1 Dip Switch 3 OFF OVER2 Dip Switch 2 OFF Current Amp 2A 1 S F Set 5Auto2 2 Over2 6 Autol 3 Over1 7 Photo 4 Autos 8 Light Dip Switch 3 ON Dip Switch 2 OFF 3A Dip Switch 3 OFF Dip Switch 3 ON Dip Switch 2 ON Dip Switch 2 ON 4A 5A 2 1 3 Gate Auto close Adjustment Dip 4 Auto 3 Dip 5 Auto 2 amp Dip 6 Auto 1 Auto close 1 Dip switch 6 OFF Auto close 2 Dip Switch 5 OFF Auto close 3 Dip Switch 4 OFF Effect No auto close Dip switch 6 ON Dip Switch 5 OFF Dip Switch 4 OFF 3 sec Dip switch 6 OFF Dip Switch 5 ON
20. ilises ON D clenchement de la g che quand DIP est ON OFF La g che ne fonctionne quand DIP est OFF 2 2 2 R glage de la vitesse de ralentissement Dip 6 Slow ON La vitesse de sortie est a de 70 de la vitesse originale OFF La vitesse de sortie est a de 50 de la vitesse originale 2 2 3 R glage de la vitesse de fonctionnement Dip 7 Fast ON La vitesse de sortie est 100 de la pleine vitesse OFF La vitesse de sortie est a de 70 de la pleine vitesse 2 2 4 Fonctionnement du portail 1 ou 2 vantaux Dip 8 Ds Set ON 2 vantaux OFF 1 vantail 2 3 Indication de LED LED1 L apprentissage du syst me LED1 clignote une fois lorsque l apprentissage 1 vantail est achev LED1 clignote deux fois lorsque l apprentissage pour deux vantaux est achev LED2 RF Si l interrupteur de t l commande s lecteur cl ou bouton est activ LED2 est allum LED3 Photocellules 1 LED3 s allume lorsque la premi re paire de photocellules est activ e LED4 Photocellules 2 LED4 s allume lorsque la deuxi me paire de photocellules est activ e LED5 RF Indicateur LED5 s allume lorsque le signal 433 92 MHz est re u Switch nm LED1 H SYSlearn LED2 LT mi im RFLED 3 5 Oz RERET aaaagaa s al LED3 A ep 5212 pro ZI Ph01 LED4 E Pho2 CI LED5 ml RFlearn 2 4 M morisation et l effacement de vos telecommandes A appuyez 1 second
21. is completed when the blue indicator is OFF B Transmitter Memory Erasing Press and hold the S3 button on the PCB for three seconds C One radio receiver can be memorized with 200pcs of transmitters 2 5 System Learning Process Step1 Connect the master motor wires to M1 terminals and the slave motor wires to M2 terminals correctly If only one gate is installed the motor wires have to be connected to M1 terminals Step2 Press and hold the S2 button on the PCB for 5 seconds After LED1 blinks once per second press the button on the transmitter to choose dual gate A button or single gate B button system learning In system learning mode the gates will proceed with the following procedures A Dual Gate Mode Slave Gate closes Master Gate closes Master Gate opens Slave Gate opens Slave Gate closes Master Gate closes B Single Gate Mode Master Gate closes Master Gate opens Master Gate closes The completion of system learning A For Dual Gate installation The system learning is completed when LED1 quickly blinks twice per second B For Single Gate installation The system learning is completed when LED1 quickly blinks once per second Notes A System learning fails and needs to be learned again when an unpredictable interruption occurs B Once the system learning is completed there is no need to proceed with the learning process again when there isa power failure C The slave gate opens 3 seconds
22. justment of The Gear Motors Dip 6 Slow 2 2 3 Operation Speed Adjustment of The Gear Motors Dip 7 Fast 2 2 4 Single and Dual Gate Operation Adjustment Dip 8 Ds Set 2 3 LED Indication 2 4 Transmitter Memorizing and Erasing Process 2 5 System Learning Process 2 6 Gate Operation 2 7 Gate moving Logic 2 8 Advanced Operation of the Transmitter DIODIAIaAan HIRI IHR IHR IR IR TR TR jojojo 3 Trouble Shooting 1 Control Box CONTROL BOX INSTALLATION 1 Decide the installation position of control box first it is suggested to be installed near the gate and should be protected from possible damage Be aware of the motor cable length before deciding the installation position 2 Remove the cover by unscrewing the four screws on the cover See Figure 1 1 3 Use a screwdriver to puncture the holes beneath the bottom of the control box See Figure 1 2 4 Secure it on the wall See Figure 1 3 CAUTION There is control board inside punch with care do not damage the board Figure 1 1 Figure 1 3 5 Wiring Connection Prepare all the wires of the accessories beforehand and connect the wires to the gear motors and accessories on the PCB as shown in Figure 1 4 All of the wiring connections of the accessories are not requested to distinguish the positive and the negative polarity 1 PF 1 Flashing light Connect the two wires from the flashing light to the terminal LIT and LIT on the PCB 2 PEL 1 Electric
23. motoris la terre pendant la phase de raccordement au r seau lectrique 5 L installation n cessite un personnel qualifi avec des comp tences m caniques et lectriques 6 Placez les commandes automatiques hors de port e des enfants 7 Pour remplacer ou r parer le syst me motoris utilisez uniquement des pi ces d origine Aucun dommage caus par l utilisation de pi ces d autres provenances et des m thodes non conformes celles indiqu es dans ce manuel ne seront approuv es et reconnues par le fabricant 8 En cas de doute ne jamais faire fonctionner l installation au risque de l endommager 9 N utilisez la t l commande que lorsque vous avez une vue compl te du portail X Durable D verrouillage Facile 24V pour plus Mat riaux solides D verrouillage manuel Un systeme L installation et de s curit pour usage durable facile pour une silencieux pour l interface utilisateur meilleure protection plus de confort conviviale et simple 1 2 INSTALLATION A INSTALLATION DE L AUTOMATISME 1 24V DC feu clignotant avec antenne int gr e 2 Bouton 3 Centrale de commande ZA 4 Photocellule 5 24V DC automatisme de portail battant E o 6 Telecommande TABLEAU DE DIMENSIONS Pour une installation correcte se conformer aux mesures indiqu es sur le tableau Ajustez si necessaire la structure de portail pour adapter la motorisation Avant de proc der l installa
24. or proper installation Adjust the gate structure to fit it for best automation if necessary Before preceding the installation be sure that gate moves freely and that 1 Hinges are properly positioned and greased 2 No obstacles in the moving area 3 No frictions between two gate leafs or with the ground while moving AB 140 1150 160 170 180 190 200 210 MOTOR FIXING Assemble the rear bracket and fix it on the pillar Remove the wire cover and fix the rear bracket with the pin Release the gate opener and place the pin into the fitting position no 1 and no 2 Make sure the gate openers are mounted in horizontal position especially in those positions 1 Gate in CLOSE position 2 Gate in OPEN position 3 Gate at 45 angle position Prior to weld the bracket on the gate leaf if necessary cover the gate opener to prevent damages from sparks TO CONNECT MASTIFF WITH CONTROL UNIT Standard Motor With Hall Sensor sor fe me ere Ooo 9 Bick Hall Sensor GND E EMERGENCY RELEASE In case of power failure push the lid of release chamber and move forward Insert the key and turn clockwise to unlock then turn around the knob to release To restore the automation simply reverse the above procedures Step1 Push the lid of release chamber and move forward Step2 Insert the key and turn clockwise to the unlock position Step3 then turn clockwise the knob to release
25. r replace or repair of the motorized system only original parts must be applied Any damage caused by inadequate parts and methods will not be claimed to motor manufacturer 8 Never operate the drive if you have any suspect with what it might be faulty or damage to the system 9 The motors are exclusively designed for the gate opening and closing application any other usage is deemed inappropriate The manufacture should not be liable for any damage resulting from the improper use Improper usage should void all warranty and the user accepts sole responsibility for any risks thereby may accrue 10 The system may only be operated in proper working order Always follow the standard procedures by following the instructions in this installation and operating manual 11 Only command the remote when you have a full view of the gate Please keep this installation manual for future reference Key Release EZ Instal eu Low Voltage Durability 24V power supply Solid material apply Manual release device Worm gear application Easy installation for great safety with lasting usage with easy use and give silence operation and user friendly highly protection interface 1 2 STANDARD INSTALLATION A STANDARD INSTALLATION 1 24V DC blinker with antenna 2 Push Button 3 Control Box 4 Photo Sensor 5 24V DC gate opener 6 Transmitter DIMENSION CHART Comply with the measures shown on the chart f
26. rnier J4 2 G che Connectez les deux fils de la gache a LAT et LAT sur le bornier J4 3 Automatismes portails Referez vous au schema 1 4 et connectez les fils separement sur les borniers Moteur 1 Connectez le fil du moteur Blanc M1 et Jaune M1 bornier J4 moteur qui s ouvre en premier Raccorder les fils vert rouge noir bornier J5 M2 de l encodeur aux bornes 5V S1 et GND Moteur 2 Connectez le fil du moteur Blanc M2 et Jaune pour le M2 moteur qui s ouvre en second Raccorder les fils vert rouge noir de l encodeur aux bornes 5V S2 et GND bornier J5 Note Pour portails s ouvrant vers l ext rieur M1 Connectez le fil du moteur Jaune M1 et Blanc pour le M1 M2 Connectez le fil du moteur Jaune M2 et Blanc pour le M2 4 Photocellules Voir sch ma 1 4 page suivante A Installez une paire de photocellules Rep res 7 et 9 Retirez le cavalier lectrique JP1 Sch ma 1 4 B Installez deux paires de photocellules Rep res 7 9 et 8 10 Retirez les deux cavalier lectrique JP2 et JP1 Sch ma 1 4 E E Ph 02 E RF Indic 4 w mm E LED2 mg LEDS gy LED4 Sch ma 1 4 Transformateur J2 12345678 12345678 BAT BAT 24V RF leam SYS learn Fusible 2 2 D Le
27. t a st Anette Se de Rae ses Ges ata eat dale P 2 A Standard Installation P 2 B Dimension Chart P 2 C MotoriFixing P3 D Wire Connection i catia eed Seed Sane at A a ie P 3 E Emergency Release ysr eee ee bee dade sd elds shea at i P4 1 3 Technical Features P 4 iA M inten nce i otet ac dur ee nat MEd dade UE handle a aug P5 1 1 GENERAL PRECAUTION WARNING This user manual is only for qualified technicians who is specialized in installations and automations 1 All installations electrical connections adjustments and testing must be performed only after reading and understanding of all instructions carefully 2 Before carrying out any installation or maintenance operation disconnect the electrical power supply by turning off the magneto thermic switch connected upstream and apply the hazard area notice required by applicable regulations 3 Make sure the existing structure is up to standard in terms of strength and stability 4 When necessary connect the motorized gate to reliable earth system during electricity connection phase 5 Installation requires qualified personnel with mechanical and electrical skills 6 Keep the automatic controls remote push bottom key selectors etc being placed properly and away from children 7 Fo
28. tion assurez vous que la porte se d place librement 1 Les charni res sont positionn s correctement et sont graiss s 2 V rifiez qu il n y ait aucun obstacle dans la zone de d placement 3 V rifiez qu il n y ait pas de friction entre les deux portails ou dans le sol pendant le d m nagement AB 140 150 1160 170 180 190 200 210 FIXATION DU MOTEUR Assemblez le support et fixez le sur le pilier Retirez le couvercle et fixer le support avec la broche Lib rez l automatisme et placer la broche dans la position de montage no 1 et no 2 A l aide d un niveau assurez vous que le portail garde sa position horizontale dans les axes suivants 1 Portail en position ferm 2 Portail en position ouvert 3 Portail ouvert a 45 Connecter CALYPSO avec unite de contr le Moteur Avec capteur standard a effet Hall oara Over Capteur encodage Signal 9 Noir Capteur encodage GND E DEVERROUILLAGE D URGENCE Lors d une panne de courant poussez le couvercle et l avancer Ins rez la cl tournez dans le sens des aiguilles d une montre pour d verrouillez puis tournez le bouton pour lib rer l ouverture Pour refermer il suffit d inverser les proc dures ci dessus Etape 1 Poussez le couvercle et l avancer Etape 2 Ins rez la cl et tournez dans le sens des aiguilles d une montre jusqu la position d verrouill e Etape 3 Puis tourner le
Download Pdf Manuals