Home

BUF-011/021 - Custom Service Hardware

image

Contents

1. 3 Connecting Power Supply Wires A WARNING e Electrical wiring should be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction An unqualified person doing the work could result in fire electric shock or injury e This range hood uses 120V AC Do not connect to other voltage since fire electric shock or damage could result Conduit 1 Remove the nut not supplied from the conduit connector at the end of power wiring i N ZN WARNING en Be sure to switch power OFF at service panel before wiring 2 Connect the conduit through the connecting hole of the enclosure using the nut previously removed Conduit H Wire box 3 Connect the electrical wires as follows Connect wires tightly and securely using wire connectors not supplied e Black to Black White to White Green to Green Wires conduit side Wire connector not supplied Wires unit side Replace the wire cover with the screw removed previously Make sure that all wires are connected properly and enclosed inside of the wiring compartment Slant the wire cover as shown D Replace the wire cover with tilting it and rotate its screw hole part the screw 3 Insert 2 tabs and tighten 4 Final Assembly and Check 7 Ass
2. hood INSTALLATION 4 Remove the following parts by following steps 1 Filter Loosen 2 knobs and detach the slot filters 2 Front cover Remove 4 screws fixing the front cover and detach it Front cover 1 Detach 2 tabs 2 Slant the wire cover 8 Remove the wire cover by lifting and rotating it as illustrated after removing the screw 2 Range Hood Mounting A CAUTION e Wear working gloves to avoid injury 7 Hold up the range hood and insert it into the opening of the liner When the 4 securing plates on both sides have passed through the top of the liner turn them outward to secure the range hood on the liner temporarily Make sure the top of the exhaust pipe is inserted into the bottom of the duct Securing plate each side two 2 places Securing plate N Securing plate turns while passing through Range hood unit the opening of Liner Align 4 screw holes of the liner and range hood unit then fix securely using the supplied screws and nuts Note Fasten all the screws and nuts evenly a Nut with plate Nut with plate left amp right each Range hood unit two 2 places Four 4 screws M5x30 Make the duct joint secure and air tight using non flammable tape such as duct tape etc not supplied Note Make sure that the shutter installed in the exhaust pipe moves freely
3. hotte d aspiration sous tension 2 V rifiez si les interrupteurs et l clairage fonctionnent correctement Reportez vous en page 4 du mode d emploi 3 Assurez vous que la hotte d aspiration n mette pas de bruit anormal et ou de vibrations Enfonc AN PR CAUTION e Pour viter de vous blesser loignez vos mains et les objets du ventilateur lorsqu il tourne e Mettez des gants de travail pour viter de vous blesser 5 Explications l utilisateur 1 Expliquez le fonctionnement de cette hotte d aspiration l utilisateur en vous r f rant au mode d emploi 2 Le manuel d installation et le mode d emploi doivent tre remis l utilisateur
4. 1U03 2182 Model BUF 011 021 SAFETY INSTRUCTIONS Before installation and operation read these instructions carefully and use this product only in the manner described by the manufacturer in the operation manual The instruction shown below are used to alert you to potential personal injury and property damage hazards There are three hazard classifications based on potentially dangerous situations Obey all safety instructions that show these symbols to avoid possible injury death and property damage AN WARNING WARNING indicates a potentially A CAUTION CAUTION hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage NOTE The safety instructions are explained with the following 9 0 0 pictographic symbols means prohibition It indicates actions if any that mustn t be done means forcible execution It indicates actions if any that must be done WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit swi
5. RAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fan must always be vented to outdoors TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK This unit must be grounded Check that the hood is correctly installed since incorrect installation could result in the range hood becoming detached and falling off Connect only to an AC120 Volt power source or the range hood could result in fire electric shock and damage dom N CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive material and vapors To reduce the risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls ceilings or into attics crawl spaces or garages Read specification label on this product for further information and requirements Use only for the purpose of kitchen ventilation Do not install this range hood in the bathroom or in other wet rooms since electrical shock and damage may result Fasten the filter and other parts securely Incorrect attachment may result in personal injury or property damage Keep your hands and other objects away from the fan while it is in motion The range hood may injure you or damage itself 18 11 16 475 Enclos Lamp MR16 GU10 35Watt not supplied FD Switch ACCESSORIES Screw M5x30 Four 4 p
6. d aspiration risque de se d tacher et de tomber Placez le c blage domestique entre le panneau de service et l emplacement de la hotte Tuyau d chappement 4 Pr parez la hotte d aspiration 1 La hotte d aspiration est livr e avec le tuyau d chappement fix sur la plaque sup rieure 2 Disposez l extr mit du conduit rond de 6 et de la conduite du c blage de fa on que vous puissiez les connecter sur le haut de la hotte d aspiration Z 3 Pr voyez une longueur de recouvrement de 1 3 16 pour le tuyau d chappement et la conduite 1 3 16 Chemise SVS N PRECAUTION Pour ventilation g n rale uniquement Ne pas utiliser pour vacuer des substances ou des vapeurs dangereuses ou explosives Pour r duire les risques d incendie et pour vacuer correctement l air veillez conduire l air vers l ext rieur N vacuez pas l air dans des espaces comportant des murs et des plafonds ou dans les greniers les espaces confin s ou les garages Lisez l tiquette des sp cifications de cet appareil pour des informations et renseignements suppl mentaires Utilisez uniquement cet appareil pour la ventilation de la cuisine N installez pas la hotte d aspiration dans la salle de bains ou dans d autres pi ces humides car des lectrocutions ou des d g ts peuvent se produire Fixez correctement le filtre et les autres pi ces Une fixation inc
7. embly 1 Replace the front cover with 4 screws To prevent the screw holes from being damaged be sure not to over tighten the screws with the torque of 13 inch lbs 1 5 N m or less 2 Replace the filter 3 Install two light bulbs Two 35 W halogen light bulbs not supplied can be mounted to this range hood Prior to function check install light bulbs Bulb type MR16 GU10 rated 120 V 35 W or below Note When installing the bulb be sure to fix to the socket securely Push the lamp and turn it clockwise Lamp MR16 GU10 35W not supplied 2 Check 1 Turn on the electrical circuit to the range hood 2 Make sure that the switch and light operate correctly Refer to page 4 of the Operation Manual 3 Make sure that the range hood has no abnormal noises and or vibration pe pe Push to turn ON A CAUTION e To reduce the risk of injury keep your hands and other objects away from the fan while it is in motion e Wear working gloves to avoid injury 5 Explanation to the End User 1 Referring to the Operation Manual explain the operation of this range hood to end users 2 The Installation Manual and Operation Manual should be given to the end user 1U03 2182 Modele BUF 011 021 Lisez attentivement ces instructions avant d installer et de faire fonctionner l appareil et utilisez celui ci uniquement de la mani re indiqu e par le fabricant dans le mode d empl
8. ge RANGE HOOD The range hood unit must be mounted to a liner which has the following dimensions Install the liner securely after checking that the opening size of the liner is the same as the figure below 18 11 16 17 3 8 1 16 Liner 4 1 4 holes for fixing screw Center line 11 11 16 Opening for Range hood 2 1 16 Unit inch mm The liner should be installed tightly If the liner installation is not correct the range hood unit may become detached and fall Run house wiring between service panel and hood location Exhaust pipe Prepare the range hood unit 1 The range hood is supplied with the exhaust pipe fixed on its top plate 2 Arrange the ends of 6 round duct and wiring conduit so that they can connect with the top of the range hood unit 3 Be sure to keep 1 3 16 overlapping length of the exhaust pipe and duct fa as 5 Range hood unit 1 3 16 Liner Range Hood INSTALLATION MANUAL NAMES OF PARTS b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and The American Society for Heating Refrigeration and Air Conditioning Engineers ASH
9. i incendie 1 Pr paration A ATTENTION e Si la hotte d aspiration n est pas correctement install e elle peut se d tacher et tomber e Assurez vous que la conduite m tallique n entre pas en contact avec d autres mat riaux de rev tement ceci pouvant provoquer un incendie ou une lectrocution V rifiez si la hotte d aspiration 5 Cache de plafond vacue verticalement ou Conduite ronde horizontalement conduite de 6 pour ronde de 6 Pour l vacuation si verticale ou horizontale faites passer la conduite entre le placement de la hotte et une garniture de toit ou une nirados garniture de mur Pour obtenir Cache mural les meilleurs r sultats utilisez p un minimum de transitions ou de coudes pensez bien fixer cor un cache de plafond ou un Hotte daspirationf PR cache mural pour viter toute horizontale 2 La hotte d aspiration doit tre mont e sur une chemise ayant les dimensions suivantes Installez la chemise solidement apr s avoir v rifi que la taille de l ouverture de la chemine est la m me que sur la figure ci dessous 18 11 16 17 3 8 1 16 Chemise 4 1 4 Orifices de vis de fixation Axe 11 11 16 Ouverture de la hotte d aspiration Unit pouces mm Tir A AN PR CAUTION e La chemise doit tre install e sans jeu Si la chemise n est pas install e correctement la hotte
10. ieces Nut with plate Four 4 pieces DIMENSIONS Unit inch mm 5 3 16 131 17 1 4 5 15 16 2150 19 11 16 13 FUJIOH CIRCUIT DIAGRAM Fan Switch D a Connector ae et Pilot Lamp LIL Connector TT Grey dot Yellow Yellow 3 i t Lamp 35W Connector _ al White White _ __ 4 Black Connector White at Connector White IWhite Blue Blue Browni Brown Capacitor RANGE HOOD LOCATION The range hood must be installed just above the cooktop The minimum distance from the cooking surface to the bottom of the range hood must be 24 Liner inimum 3 The total weight of the BUF 011 021 range hood unit is 18 Ibs 8 kg 4 Power requirements are BUF 011 AC120 V 60 Hz 1 7 Amp BUF 021 AC120 V 60 Hz 2 2 Amp N CAUTION e Check that the hood is correctly installed since incorrect installation could result in the detachment of the range hood and the unit could fall e To protect hands from injury wear working gloves when installing the range
11. oi Les instructions indiqu es ci dessous sont utilis es pour vous avertir des blessures personnelles ou des d g ts pouvant ventuellement se produire Les avertissements ont t classifi s en trois cat gories sur la base de situations potentiellement dangereuses Respectez les consignes de s curit indiqu es par ces symboles pour viter les blessures la mort ou les d g ts mat riels AN ATTENTION ATTENTION indique une situation potentiellement dangereuse qui si elle n est pas vit e peut provoquer un d c s ou des blessures graves AN PRECAUTION PR CAUTION indique une situation potentiellement dangereuse qui si elle n est pas vit e peut provoquer des blessures mineures ou l g res PRECAUTION PR CAUTION sans le symbole d avertissement indique une situation potentiellement dangereuse qui si elle n est pas vit e peut provoquer des d g ts mat riels REMARQUE Less pr cautions de s curit sont expliqu es avec les pictogrammes suivants O signifie interdiction Indique des actions qui ne S HOTTE D APSIRATION MANUEL D INSTALLATION INSTRUCTIONS DE SECURITE b De l air en suffisance doit tre pr vu pour la bonne combustion et l vacuation des gaz par la chemin e des quipements de combustion du carburant pour viter les d charges en retour Suivez les directives du fabricant de l appareil de combustion ainsi que les normes de s curit comme celles publi es
12. orrecte peut provoquer des blessures personnelles ou des d g ts mat riels Eloignez vos mains et les objets du ventilateur lorsqu il tourne La hotte d aspiration pourrait vous blesser ou tre elle m me endommag e TAILLE ET DIMENSIONS 18 11 16 475 Unit pouces mm 5 3 16 131 2 1 4 6 17 1 4 5 15 16 2150 Orifice de montage de hotte 19 11 16 13 INSTALLATION 4 Desserrez les pi ces suivantes en effectuant les op rations ci dessous 1 Filtre Desserrez les 2 boutons et retirez les filtres fente 2 Couvercle avant Retirez les 4 vis de fixation du couvercle avant et retirez le Filtre 3 Couvercle m tallique Retirez 1 vis et proc dez indiqu ci dessous Couvercle des De i Iw Ss gt Ca O Retirez les 2 taquets 3 Retirez le cache des fils tout en soulevant la partie avec trou de vis et en la tournant Inclinez le couvercle m tallique 2 Montage de la hotte d aspiration AN PR CAUTION e Met
13. par la National Fire Protection Association NFPA The American Society for Heating Refrigeration Air Conditioning Engineers ASHRAE et les autorit s du code local Si vous d coupez ou percez un mur ou un plafond n endommagez pas le c blage lectrique ou les autres installations dissimul es Les ventilateurs conduite doivent toujours atre vacu s vers l ext rieur POUR REDUIRE LES RISQUES D INCENDIE UTILISEZ UNIQUEMENT DES CONDUITES METALLIQUES Cet appareil doit tre mis la terre V rifiez si la hotte est bien en place car toute installation incorrecte peut entra ner le desserrement et la chute de la hotte Ne branchez que sur une source d alimentation secteur de 120 volts car sinon la hotte d aspiration risque de provoquer un incendie une Vis M5x30 NOMENCLATURE Lampe MR16 GU10 35Watts non fournis Bouton Couvercle avant ACCESSOIRES FUSION SCHEMA DE CABLAGE Bouton de ventilateur Connecteur Lampe Pilote Connecteur Gris Jaune __ TT IA Jaune iJaune 11 ra 27W Lampe 35W Blanc Blanc tot Noir l Connecteur Blanc Blanc ei Noir Connecteur Connecteur Bleu Bleu Connecteur Marron Marron Orange 1Orange Blanc Blanc Rouge Rouge Lampe 35W Capaciteur EMPLACEMENT DE LA HOTTE D ASPIRATION La hotte d aspiration doit tre install e directement au dess
14. ruction anti incendie Des travaux effectu s par une personne non qualifi e peuvent provoquer un incendie une lectrocution ou des blessures Cette hotte d aspiration fonctionne sur courant secteur 120 V Ne la branchez pas sur une autre tension pour viter de provoquer un incendie une lectrocution ou des d g ts mat riels Retirez l crou non fourni du Conduite connecteur de la conduite l extr mit du c blage d alimentation al E A ATTENTION Ta ee Veillez a mettre hors tension sur le panneau de service avant de proc der au c blage Connectez la conduite par l orifice de connexion du caisson a l aide de l crou pr c demment retir Conduite H Couvercle des fils 3 Connectez les fils lectriques de la mani re suivante Serrez les fils bien fermement en utilisant des connecteurs de fils non fournis e Noir sur noir Blanc sur blanc e Vert sur vert Fil c t conduite Connecteur de fil non fourni 4 Remettez le couvercle des fils en place l aide de la vis que vous avez retiree pr c demment Veillez ce que tous les fils soient connect s correctement et enferm s dans le compartiment de cablage ins rez les 2 taquets et serrez la vis O Remettez le couvercle m tallique Inclinex le couvercle en place en l inclinant et en tournan
15. t la partie avec trou de vis m tallique comme indiqu Chemise inimum Surface de cuisson a Le poids total de la hotte d aspiration BUF 011 021 est 18 Ibs 8 kg L alimentation lectrique requise est de BUF 011 CA120 V 60 Hz 1 7 Amp BUF 021 CA120 V 60 Hz 2 2 Amp N PRECAUTION e V rifiez que la hotte d aspiration est correctement install e une installation incorrecte peut entra ner le d tachement de la hotte d aspiration et l appareil pourrait tomber e Pour vous prot ger les mains mettez des gants de travail lorsque vous installez la hotte d aspiration 4 Montage Final et v rification 1 Montage 1 Remettez le couvercle avant en place avec 4 vis Pour viter que les orifices de vis ne s ab ment ne serrez excessivement les vis couple de 1 5 N m 13 pouces lb ou moins 2 Remettez le filtre en place 3 Installez deux ampoules neuves Vous pouvez installer deux ampoules halog ne de 35W non fournies dans cette hotte d aspiration Avant de v rifier le fonctionnement fixez les ampoules type d ampoule MR16 GU10 d une capacit nominale de 120 V 35 W ou moins REMARQUE Lorsque vous installez ampoule fixez la solidement sur la douille A F Appuyez sur l ampoule puis tournez la dans le sens des aiguilles d une montre J Lampe MR16 GU10 35W non fournis 2 V rification 1 Mettez le circuit lectrique de la
16. tch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel To reduce the risk of fire or electric shock do not use this product with any solid state speed control device TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire a gt XX 2606600 rated construction 1 Preparation A WARNING A CAUTION 3 If the range hood is not installed properly it could become detached and fall Ensure that the metal duct does not touch other metal housing materials otherwise fire or electric shock could result According to the conditions ROOF CAP where the range hood is 6 ROUND DUCT installed determine whether it For venical Re discharge will discharge vertically or horizontally 6 Round duct For vertical or horizontal discharge run duct work between the hood SOFFIT location and a roof cap or wall WALL CAP cap For the best result in either direction use a minimum number 4 of transitions and elbows Be sure to attach a roof cap or wall cap to avoid water leakage 6 ROUND DUCT For horizontal dischar
17. tez des gants de travail pour vitar de vous blesser 1 Saisissez la hotte d aspiration et ins rez la dans l ouverture de la chemise Lorsque les 4 plaques de fixation des deux c t s sont entr es dans le haut de la chemise tournez les vers l ext rieur pour fixer provisoirement la hotte d aspiration sur la chemise V rifiez que le tuyau d chappement est bien ins r dans le fond de la conduite Conduite r Conduite H Plaque de fixation deux 2 endroits chaque La plaque de fixation tourne quand vous la passez dans louverture de Hotte d aspiration la chemise 2 Amenez les 4 orifices de vis de la chemise en regard de ceux de la hotte d aspiration puis fixez solidement l aide des vis et des crous fournis REMARQUE Serrez toutes les vis et les crous de fa on uniforme lt gt Ecrous avec plaque Ecrous avec plaque droite et gauche Hotte d aspiration deux 2 endroits chaque Quatre vis M5x30 Serrez le joint de conduite et rendez le tanche lair avec du ruban ignifuge comme du ruban en aluminium etc non fourni Conduite Ruban de conduite etc REMARQUE V rifiez que l obturateur install dans le tuyau d chappement bouge librement Hotte d aspiration A 3 Connexion des c bsles d alimentation A ATTENTION e Le c blage lectrique devra tre effectu par une ou des personnes qualifi es conform ment aux codes et normes applicables y compris la const
18. us de la AIX Ecrous avec plaque Quatre 4 pieces dom doivent pas tre effectu es lectrocution et des d g ts Quatre 4 pieces GUISINIEIE Une distance minimum de 24 doit tre pr vue entre la surface de signifie ex cution forc e Indique des actions qui cuisson et le bas de la hotte d aspiration doivent tre ex cut es N ATTENTION 1 POUR R DUIRE LES RISQUES D INCENDIE D ELECTROCUTION OU DE BLESSURES PERSONNELLES OBSERVEZ LES PRECAUTIONS SUIVANTES Utilisez cet appareil uniquement de la mani re indiqu e par le fabricant Si vous avez des questions contactez le fabricant Avant de r parer ou de nettoyer l appareil mettez le hors tension sur le panneau de service et coupez le courant de rupture de service pour viter que l appareil ne soit remis sous tension accidentellement Si le courant de rupture de service ne peut pas tre coup fixez un moyen d avertissement visible comme une tiquette sur le panneau de service Pour r duire les risques d incendie ou d lectrocution n utilisez pas cet appareil avec un dispositif de commande de vitesse semi conducteurs POUR R DUIRE LES RISQUES D INCENDIE D ELECTROCUTION OU DE BLESSURES PERSONNELLES OBSERVEZ LES PRECAUTIONS SUIVANTES Les travaux d installation et le c blage lectrique devront tre effectu s par une ou des personnes qualifi es conform ment aux codes et normes applicables y compris la construction ant