Home

Owner`s and Installation Manual Manuel d`installation et d`utilisation

image

Contents

1. www thetford com VveSO000L 1 75 2 0 Bezel Hole Size Dimension du trou de la plaque Tama o del orificio del marco Tecma EasyFit Owner s amp Installation Manual Installation Options Options d installation Opciones de instalaci n Choose the method that best fits your Choisissez la m thode qui convient le Elija el m todo de instalaci n que se installation needs m INSTALLATION INSTALLATION A INSTA LACION A FRESH WATER Single or Multiple Toilets EAU DOUCE Une ou plusieurs cuvettes AGUA DULCE Inodoros individuales o multi ples 1 Automatic Fresh Water Pressure Pump Pompe refoulante automatique d eau douce Bomba de presi n autom tica de agua dulce 2 Marine Electric Solenoid Valve electronically con trolled by toilet Electrorobinet marine command par la cuvette Electrovalvula de solenoide marina bajo control electr nico del inodoro 3 Lower Discharge Check Valve Clapet antirefoulement pour l vacuation inf rieure V lvula de retenci n inferior de descarga m INSTALLATION INSTALLATION B INSTALACI N B RAW WATER PUMP Toilet ABOVE SEA LEVEL POMPE A EAU NON TRAITEE Cuvette AU DESSUS DU NIVEAU DE LA MER BOMBA DE AGUA BRUTA Inodoro POR ENCIMA DEL NIVEL DEL MAR 1 Raw Water Pump Pompe eau non trait e Bomba de agua bruta 2 Lower Discharge Check Valve Clapet antirefoulement pour l vacuation inf rieure V lvula de retenci n inferior de descarga
2. DANGER Danger de choc lectrique d incendie et d inondation N gliger de suivre ces avertissements peut entra ner des pertes mat rielles des blessures ou la mort a N utilisez que les DISJONCTEURS FUSIBLES ET CALIBRES DE C BLES RECOMMAND S PAR l ABYC m Assurez vous toujours que L ALIMENTATION LECTRIQUE est COUP E et que les ROBINETS sont FERM S ou la position ARR T avant de commencer les travaux m Sila cuvette sanitaire est reli e un raccord traversant la coque FERMEZ TOUJOURS TOUS LES ROBINETS lorsque l EMBARCATION EST INOCCUP E m me pour un court laps de temps Pour les unit s utilisant de l eau douce et qui sont certains moments reli es l aqueduc municipal par le biais d un syst me de liaison terre navire ce SYST ME DE LIAISON doit tre D CONNECT SI L EMBARCATION EST INOCCUPEE m me pour un court laps de temps m Si l unit est reli e un raccord traversant la coque TOUS les tubes flexibles directement ou indirectement raccord s entre la cuvette et TOUT raccord traversant la coque doivent tre de qualit marine et tre branch s ces letario Instalaci n del inodoro Marine Adve rtencia Lea y comprenda A las advertencias contenidas en este documento antes de instalar hacer funcionar o dar mantenimiento a este sistema El incumplimiento de estas advertencias ocasionara riesgos de p rdidas materiales lesiones y electrocuci n No modifique de
3. Smart or Aqua Clean Deodorants Thetford the industry leader offers the two holding tank deodorants that deliver unsurpassed odor control performance waste digestion and tank cleaning in their respective categories Aqua Kem and EcoSmart Tissue To facilitate flushing it is recommended that you only use toilet tissues specifically designed to disintegrate rapidly unlike household tissues such as Thetford s Aqua Soft 2 ply and RV Marine Toilet Tissue 1 ply www thetford com Garantie Pour connaitre les clauses de la garantie consultez la page de d claration de garantie incluse dans la trousse d information Nettoyage Utilisez uniquement des produits non abrasifs et non d riv s du p trole pour nettoyer la pompe Le produit Aqua Clean de Thetford est un nettoyant tout usage non abrasif sp cialement formul pour pargner tous les composants de votre syst me sanitaire N utilisez jamais des produits m nagers dans la cu vette car ils peuvent contenir des agents blanchis sants Les nettoyants m nagers pour cuvettes de toilette contiennent des acides corrosifs Les produits blanchissants les d riv s du p trole les acides cor rosifs et les abrasifs peuvent causer des dommages irr versibles au syst me sanitaire et ses composants Hivernisation N utilisez que de l antigel non toxique base de pro pyl ne glycol pour pr parer les toilettes pour les p ri odes de gel N ut
4. de des carga de la bomba maceradora est halada hacia abajo Enderece la manguera de descarga para que su parte supe La manguera rior quede en l nea con ly la boquilla la boquilla del inodoro deben estar al N OTA Esta gu a de resoluci n de problemas tiene la finalidad de servir de ayuda b sica en caso de funcionamiento incorrecto del inodoro Si las acciones sugeridas no resuelven el problema quiz s sea necesario enviar la unidad para que reciba servicio profesional Servicio al cliente de Thetford 1 800 521 3032 Tecma EasyFit Owner s amp Installation Manual 14 www thetford com Service Kits Ensembles de r paration Juegos de servicio ART00198a Description Description Descripcion Seat amp Cover Si ge et couvercle Asiento y tapa Nozzle Embout Boquilla Pump amp Discharge Tube Pompe et tuyau d vacuation Bomba y tubo de descarga Motor Bracket Support de moteur Soporte del motor Water Inlet Prise d eau Entrada de agua DE ES 2 Dane Tie Ro de DER ES Solenoid 12V Electrorobinet 12V Solenoide 12 V Water Pump Kit Ensemble de pompe eau Juego de la bomba de agua www thetford com 15 Tecma EasyFit Owner s amp Installation Manual
5. f unit is connected to any through hull fittings ALL flexible tubing connected directly or indirectly between toilet and ANY through hull fitting must be of marine quality and must be connected to each fitting with TWO 2 STAIN LESS STEEL WORM DRIVE HOSE CLAMPS These HOSE CLAMPS must be INSPECTED FREQUENTLY TO ENSURE TIGHTNESS thereby preventing leaks m f unit is connected to any through hull fittings PROPERLY INSTALLED SEACOCKS MUST BE INSTALLED to Owner s and Installation M CE 6 Pe 10n 02 3461 nual Manuel d installation et d utilisation Manual de instalaci n y del pro Installation de la cuvette Marine Avertissement Prenez connaissance des avertissements et des mises en garde figurant dans ce document avant d installer d utiliser ou d entretenir ce syst me Ignorer ces avertissements peut conduire des pertes mat rielles des blessures ou une lectrocution N apportez aucune modification cette unit au risque de causer des dommages mat riels des blessures ou une lectrocution Thetford Corporation d cline toute responsabilit relative des dommages mat riels blessures ou mortalit s d coulant d une installation d une r paration ou d une utilisation incorrecte de ce syst me Thetford Corporation recommande que les travaux de plomberie et d lectricit soient ex cut s par un professionnel muni d une licence Un permis local et le respect du code sont exig s
6. seal ants that can damage plastic Attention Appliquez un calfeutrant base de silicone ou de latex N utilisez pas de calfeutrants base de polysulfide car ils attaquent le plastique q Precauci n obture con sellantes de silicona o a base de l tex No utilice sellantes a base de polisulfuro porque pueden www thetford com Operation Fonctionnement Funcionamiento Warranty For defined warranty terms review the one page war ranty statement included in the information packet Cleaning Use only non abrasive non petroleum products to clean the pump Thetford s Aqua Clean is a non abra sive all purpose cleaner specially formulated to be safe for all components of your toilet system Never use household cleaners which can contain bleach in the toilet system Household toilet bowl cleaners contain harsh acids Bleach petroleum based products strong acids and abrasives can cause irre versible damage to the toilet system and components Winterizing Use only propylene glycol based non toxic antifreeze when storing toilet during freezing conditions Never use automotive antifreeze or windshield washer solvent to winterize Make sure that both the entire supply and discharge systems are thoroughly winterized to ensure complete protection for your system Storage When storing the system for more than two weeks thoroughly clean toilet and hoses by flushing with Thet ford s Aqua Kem Eco
7. 3 Filter or Strainer Filtre ou cr pine Filtro o tamizador INSTALLATION INSTALLATION INSTALACI N C RAW WATER PUMP Toilet BELOW SEA LEVEL POMPE A EAU NON TRAITEE Cuvette EN DESSOUS DU NIVEAU DE LA MER BOMBA DE AGUA BRUTA Inodoro POR DEBAJO DEL NIVEL DEL MAR 1 Raw Water Pump Pompe eau non trait e Bomba de agua bruta 2 Vented Loop minimum 3 4 diameter Boucle de ventilation d au moins 19 mm 3 4 po de diam tre V lvula antisifon di metro de 19 mm 3 4 pulg m nimo 3 Lower Discharge Check Valve Clapet antirefoulement pour l vacuation inf rieure V lvula de retenci n inferior de descarga 4 Filter or Strainer Filtre ou cr pine Filtro o tamizador Tecma EasyFit Owner s amp Installation Manual mieux vos besoins pour l installation adapte mejor a sus necesidades SEA LEVEL cuvettes robinets NIVEAU DE 7 hacia otros inodo FAMER To Holding Tank ros o v lvulas NIVEL DEL Vers le r servoi Hacia el tanquel de retenci n R servoir d eau douce ART00199 anque de agua dulce EA LEVEL IVEAU DE LA MER To Holding Tank Vers le r servoir d eaux us es NIVEL DEL MAR o A o e a lt Hacia el tanque de retenci n SEA LEVE NIVEAU DE LA MER NIVEL DEL MAR To Holding Tank Vers le r servoir d eaux us es Hacia el tanque de retenci n ARTOO200 1 www thetford com Installation Installation Instalaci n Note Refe
8. EMPS SI ES NECESARIO 20 cm por encima de la l nea de flotaci n EN TODO MOMENTO Fresh Water Install Installation d eau douce Instalaci n de agua dulce ART00203 Fresh Water Hook up Raccord de pompe d eau douce Conexi n de agua dulce Arn s de cableado Marco Fig F Interruptor de pared Faisceau de cables Plaque Fig F Interrupteur mural Wiring Harness Bezel Fig F Wall Switch Thetford Water Pump Raw Water Install Raw Water Pump Hook Up Pompe a eau Thetford installation d eau non trait e Bomba de agua Thetford instalaci n de Raccord de pompe d eau non trait e agua bruta Clapet antirefoulement pour l vacuation inf rieure Conexi n de la bomba de agua bruta Lower Discharge Check Valve Vertical verticale V lvula de retenci n inferior de descarga vertical Filter or Strainer Raw Water Install Filtre ou cr pine installation d eau non trait e Filtro o tamizador instalaci n de agua bruta Water Tank Fresh Water Install R servoir d eau installation d eau douce Tanque de agua instalaci n de agua dulce Pompe eau d une autre marque que Thetford installation d eau non trait e Non Thetford Water Pump Raw Water Install Bomba de agua no Thetford instalaci n de agua bruta Fresh Water Pressure Pump Fresh Water Install Bomba de presi n de agua dulce instalaci n de agua dulce Pompe refoulante d eau douce installation d eau douce Suministro de agua d
9. IN LOS ACCESORIOS PL STICOS DE LOS ORIFICIOS DE MONTAJE El inodoro podr a aflojarse o da arse si se instala de manera incorrecta m S lo se deben echar desechos humanos y papeles higi nicos en el inodoro No descargue nunca OTROS MATERIALES p ej toallas de papel toallitas prehumedecidas condones productos de higiene femenina hilo dental basura dom stica etc Discharge Hoses This toilet is designed to discharge waste into a 1 5 ID marine grade sanitation hose pipe IMPORTANT use only marine quality reinforced hoses for installation Rigid PVC pipe may also be used for the discharge line If using flexible hoses avoid sharp bends that may cause the hose to kink and restrict flow and secure the hoses to prevent abrasion Always inspect the final installation for leaks Tecma EasyFit Owner s amp Installation Manual Tuyaux d vacuation Cette cuvette est con ue pour vacuer les eaux us es dans un tuyau tube sanitaire de qualit marine de 38 mm 1 1 2 po de diam tre int rieur REMA RQ UE Nutiisez que des tuyaux renforc s de qualit marine Vous pouvez galement utiliser du tuyau de PVC rigide pour la conduite d vacuation Si vous utilisez du tube flexible vitez les courbes serr es pouvant couder le tube et restreindre son d bit et fixez le pour viter l abrasion V rifiez toujours que l installation finale est exempte de fuites Mangueras de descarga Este inodor
10. VELVI by THETFORD EasyFit Marine Toilet Installation A Warning Read and understand the warnings listed in this document before you install operate or service this system If you do not obey these warnings there is a risk of property loss injury or electrocution Do not make any changes to this unit as this could result in property damage injury or electrocution Thetford Corporation accepts no responsibility or liability for damage to equipment injury or death that may result from the system s improper in stallation service or operation Thetford Corporation recommends that plumbing and electrical work be performed by a licensed tradesperson Local permit and code compliance is required Warning Danger of Electric Shock Fire and Flooding Failure to heed these warnings can result in loss of property injury and death m Always use ABYC RECOMMENDED CIRCUIT BREAKER FUSE AND WIRE GAUGE m Always be sure units ELECTRICAL POWER is TURNED OFF and that SEACOCKS are CLOSED or in the OFF position before begin ning work m f Toilet is connected to any through hull fittings ALWAYS CLOSE or TURN OFF ALL SEA COCKS when BOAT IS UNATTENDED even if only for a minimal time m For units using fresh water that are at any time connected to shore side municipal water supply systems SHORE SIDE SYSTEM must be DIS CONNECTED IF BOAT IS LEFT UNATTENDED even if only for a minimal time m
11. aible V rifiez que la tension d alimentation de la cuvette est de 12V 2V 24V 2V ET qu il n y a pas moins de 10 de diminution de la tension lorsque le mac rateur est en marche Si la tension diminue davantage il peut y avoir un probl me de c blage dans l embarcation L eau ne p n tre pas dans la cuvette durant la chasse ou le cycle d ajout d eau Conduite d arriv e d eau tordue ou non raccord e V rifiez que la conduite d arriv e d eau est correctement raccord e l alimentation d eau douce Assurez vous qu elle n est tordue nulle part Pompe eau sans lectricit V rifiez que le fusible ou le disjoncteur ne s est pas d clench Assurez vous que tous les connecteurs de la pompe sont ins r s a fond Lalimentation d eau est ferm e L lectrorobinet n est pas branch au module de relais s il y a lieu Ouvrez les robinets d arriv e d eau ou r tablissez le courant de la pompe d alimentation Assurez vous que le faisceau de cables est enti re ment connect L eau continue de d goutter bri vement dans la cu vette une fois le cycle de chasse d eau termin La cuvette est install e sous la ligne de flottaison et la conduite d arriv e d eau comporte une boucle de ventilation Fonctionnement normal si seule une petite quantit d eau d goutte de embout La cuvette se vide d eau apres la chasse L eau est siphonn e hors de la cuvette car le tuyau d va
12. cuation est tir vers le bas Le tuyau d vacuation de la pompe mac ration est tir vers le bas Redressez le tuyau de mani re a ce que le tuyau d vacuation soit de niveau avec l embout de la cuvette Le tuyau et l embout doivent tre d 3 niveau REMARQUE ce Guide de d pannage est con u pour vous offrir une aide de base en cas de fonctionnent incorrect de la cuvette Si les actions propos es ci dessus ne corrigent pas le probl me il peut tre n cessaire de rapporter l appareil pour recourir un service professionnel Service la client le de Thetford 1 800 521 3032 www thetford com 13 Tecma EasyFit Owner s amp Installation Manual Resoluci n de problemas PROBLEMA CAUSA ACCI N SOLUCI N El inodoro no descarga o la descarga es deficiente El tanque de desechos est lleno Vac e el tanque de desechos antes de seguir usando el inodoro Hay una obstrucci n en la entrada de la bomba Elimine la obstrucci n NO descargue objetos extra os por el inodoro Objeto s lido en el macerador DESACTIVE la energ a Trate de sacar el objeto Si no lo logra comun quese con Servicio al Cliente de Thet ford Tecma 1 800 521 3032 NO descargue objetos extra os por el inodoro Baja tensi n el ctrica Compruebe que la tensi n de entrada del inodoro sea de 12 V 2 V 24 V 2 V Y que no disminuya en m s del 10 durant
13. de descarga de desechos e Espacio para el acceso al mantenimiento m El piso donde se va a instalar el inodoro debe estar nivelado y tener suficiente resistencia como para soportar el inodoro y el peso de cualquier usuario m La estructura del piso debe tener suficiente resistencia como para que el inodoro se pueda afianzar con los tornillos suministrados 19 mm 4 pulg m nimo m El material del piso es resistente al agua para que se pueda mantener la integridad de la estructura y del anclaje Consideraciones referentes al agua bruta m La bomba de agua bruta debe instalarse firmemente en un rea seca y bien ventilada Debe estar montada en todo momento a no m s de 183 cm 6 pies por encima de la l nea de flotaci n inclinada LIGRO La bomba de agua bruta debe estar alimentada por el m dulo de rel del inodoro El uso de cualquier bomba que consuma m s de 15 amperios requiere la instalaci n de un rel contactor de bomba No conecte la bomba directamente a una fuente de alimentaci n de CC de manera que est bajo el control de su interruptor activado a presi n Si ocurriera una fuga y hubiera una conexi n directa la bomba funcionar a continuamente con el consiguiente riesgo de hundimiento de la embarcaci n y de p rdida de vidas m Se TIENE QUE instalar un filtro interno para proteger el sistema De no instalarse un filtro interno podr a anularse la garant a del producto m SE DEBER instalar una v lv
14. diferencia del papel higi nico de uso en el hogar por ejemplo los papeles higi nicos Aqua Softe 2 capas y RV Marine 1 capa de Thetford Tecma EasyFit Owner s amp Installation Manual Troubleshooting PROBLEM CAUSE ACTION SOLUTION Toilet does not flush or flush performance is poor Waste tank is full Empty waste tank before continuing to use toilet Clog at pump inlet Solid object in macerator Clear clog DO NOT flush foreign objects DISABLE power Attempt to remove object If unsuc cessful contact Thetford Tecma Service 1 800 521 3032 DO NOT flush foreign objects Low voltage Check that toilet supply voltage is 12V 2V 24V 2V AND that there is no more than a 10 decrease in voltage when macerator is running If voltage de creases more than this there may be a wiring problem in the boat Water does not enter bowl during flush or water add cycle Water supply line kinked or not connected Check that supply line is properly connected to fresh water supply Check for kinks in the supply line No power to water pump Check that fuse circuit breaker has not tripped Ensure all electrical connectors to water pump are fully mated Water supply has been turned off Open water supply valves or reconnect power to sup ply pump Solenoid not plugged into relay module where ap plicable Ensure wiring harness to solenoid is fully connected Water c
15. e 19 mm 3 4 pulg 3 4 Water Supply Raw Water Install upply Raw Arriv e d eau 19 mm 3 4 po installation d eau instalaci n de agua bruta 1 2 Water Supply Fresh Water Install non trait e Suministro de agua de 13 mm 1 2 pulg Vented Loop Arriv e d eau 13 mm 1 2 po installation d eau douce instalaci n de agua dulce Boucle de ventilation V lvula antisif n Toilet Discharge Hose Tuyau d vacuation de la cuvette Manguera de descarga del inodoro Relay Module das M dulo de rel Water Pump Wiring Fig B Module de relais Alimentation lectrique de la pompe eau Fig E Cableado de la bomba de agua Fig B Discharge Line above or below floor Holding Tank Conduite d vacuation sur ou sous le plancher L nea de descarga por encima o por debajo del piso R servoir d eaux us es Tanque de retenci n Boat Craft 12V DC Power Source Source lectrique 12V CC de l embarcation Fuente de alimentaci n de 12 V CC para la embarcaci n CO 0G OOOO OOOO OOOOOO OOO 6900600009 CO 006 6600606009 60060000 Y 0000066 600000 Mimimum 3 4 floor Plancher min 19 mm 3 4 po 19 mm 3 4 pulg del piso m n www thetford com 5 Tecma EasyFit Owner s amp Installation Manual Before starting the installation consider and plan for the following Mounting Location m Ideally the EasyFit Eco toilet should be installed in a location that is higher than the holding tank A maximum 6 rise b
16. e el funcionamiento del macerador Si la tensi n disminuye m s de eso quiz s haya un problema de cableado en la embarcaci n No entra agua a la taza del inodoro durante la des carga o el ciclo de adici n de agua La manguera de suministro del agua est torcida o no conectada Compruebe que la manguera de suministro est bien conectada al suministro de agua dulce Inspeccione la manguera de suministro para ver si tiene dobleces No hay energ a en la bomba de agua Compruebe que no se haya disparado el fusible interruptor autom tico Aseg rese de que los conec tores el ctricos a la bomba de agua est n totalmente insertados Se cerr el suministro de agua Abra las v lvulas de suministro de agua o vuelva a conectar la energ a de la bomba de suministro El solenoide no est conectado a un m dulo de rel si corresponde Aseg rese de que el arn s de cableado est comple tamente conectado El agua sigue goteando levemente en la taza despu s de finalizar el ciclo de descarga El inodoro est instalado por debajo de la l nea de flo taci n con la v lvula antisif n en la linea de suministro de agua Funcionamiento normal si s lo gotea una peque a cantidad de agua de la boquilla La taza se drena y queda sin agua despu s de la descarga El agua est fluyendo sifoneando fuera de la taza debido a que la manguera de descarga est halada hacia abajo La manguera
17. e toilet and one of the Harness Kits pictured below Parts shown below are supplied in Thetford s Harness Kits Re marque Pour installer la cuvette the Tecma EasyFit vous DEVEZ avoir la cuvette et l un des ensembles de faisceaux de c bles illustr s ci dessous 38670 38680 Pieces des ensembles de faisceaux de cables Les ensembles de faisceaux de cables Thetford contiennent les pi ces illustr es ci dessous Partes del juego de arn s Nota Para poder instalar el inodoro Tecma EasyFit es IMPRESCINDIBLE tener el inodoro y uno de los juegos de arn s que se muestran debajo Literature Documentation Material informativo ART00198 Las partes mostradas a continuaci n se incluyen en los juegos de arn s de Thetford Materials Not Provided In line Strainer if applicable 3 4 diameter water supply line Raw Water installation 3 4 diameter minimum Vented Loop if required Raw Water installation 1 2 diameter water supply line Fresh Water installation 1 1 2 diameter minimum Vented Loop if required 1 1 2 diameter Marine Discharge Hose 1 1 2 straight or 90 coupling as needed Silicone caulk white or clear Various Electrical Connectors Tecma EasyFit Owner s amp Installation Manual Mat riel non fourni Filtre sur conduite le cas ch ant Conduite d arriv e d eau de 19 mm 3 4 po de diam tre Ins
18. el sistema del inodoro con limpiad ores dom sticos que pueden contener lej a Los lim piadores dom sticos para tazas de inodoros contienen cidos agresivos Los productos con lej a derivados de petr leo cidos fuertes y abrasivos pueden causar da o irreversible al sistema del inodoro y sus compo nentes Preparaci n de la unidad para el invierno Al almacenar el inodoro en condiciones de congel aci n utilice nicamente productos anticongelantes a base de propilenglicol no t xicos No utilice nunca anticongelante de autom viles ni solventes para para brisas en la preparaci n del inodoro para el invierno Para garantizar una completa protecci n de su siste ma aseg rese de que todo el suministro y los sistemas de descarga est n completamente acondicionados para el invierno Almacenamiento Al almacenar el sistema por periodos de m s de dos semanas limpie a fondo el inodoro y las mangueras descargando el inodoro con los productos Aqua Kem Eco Smart o Aqua Clean de Thetford Desodorantes Thetford l der de la industria ofrece los dos desodoran tes para tanques de retenci n que ofrecen el mejor ren dimiento en control de los olores digesti n de desechos y limpieza del tanque en sus respectivas categor as Aqua Kem y EcoSmart Papel higi nico Para facilitar la descarga se recomienda usar nicamente papeles higi nicos espec ficamente dise ados para desintegrarse r pidamente la
19. etween the toilet and holding tank will not impact performance m Using toilet and supplied template verify that the installation site has e sufficient clearance between toilet and nearby wall so that water supply hose and discharge hose are not kinked room for maintenance accessibility m The floor supporting the toilet is level and strong enough to support toilet and weight of any potential user m The floor structure is strong enough to securely anchor toilet using supplied screws 3 4 minimum m The flooring is water resistant so structure and anchoring integrity are maintained Raw Water Considerations m The Raw Water pump must be securely mounted in a dry well ventilated area It should be mounted not more than 6 at any time above the heeled waterline R The Raw Water pump must be powered by the toilet relay module Use of any pump that draws more than 15 amps requires installation of a pump contactor relay Do not wire pump directly to a D C power source so that it is controlled by its pressure activated switch If a leak were to occur when wired directly the pump would run continuously and create risk of sinking of the boat and loss of life m An in line strainer MUST be installed to protect the system Failure to use an in line strainer may void product warranty m AVented Loop of proper diameter MUST be installed if UNDER ANY CIRCUMSTANCE or CONDITION including heel trim or load e Toilet is c
20. ficio Nota Consulte las Figuras C D y E para todas las referencias de las piezas es 1 8 drill bit M che de 1 8 po 1 8 pulg 2 plan accordingly 3 7 m planifiez en cons quence 3 7 m planear de acuerdo con ello ART00212 2 Mark cut wall 1 75 2 wall hole Tracez d coupez un trou de 4 5 5 cm Marcar hacer un orificio de 1 75 2 pulg 4 5 5 cm en la pared Place D over hole drill screw holes Placez 4 sur le trou percez les trous de vis Colocar ka sobre el orificio perforar los orificios de los tomillos de 2 3 lt id D a 2 Ss 2 lt as Connect we Connectez t K3 to E Conectar to Conectar el suministro Raccordement de agua de l arriv e d eau m Installations eau douce consultez les instructions de l Ensemble de faisceau de c bles d lectrorobinet et accessoires m Instalaciones de agua dulce v anse las instrucciones del juego de arn s de solenoide y accesorio m Instalaciones de agua bruta v anse las instrucciones del juego de arn s de solenoide y accesorios de la bomba Installations eau non trait e consultez les instructions de l Ensemble de faisceau de c bles de pompe et accessoires Tecma EasyFit Owner s amp Installation Manual Installation Con t ARTO0212 Place O locate H position cut hole Placez 6 localisez la position de H d coupez l ouvert
21. ilisez jamais d antigel pour auto ni de lave glace pour l hivernisation Assurez vous que tous les conduits d alimentation et d vacuation sont hiv ris s afin de prot ger le systeme en entier Entreposage Lors de l entreposage du syst me pour plus de deux semaines nettoyez a fond la cuvette et les tuyaux en actionnant plusieurs fois la chasse avec les produits Aqua Kem Eco Smart ou Aqua Clean de Thetford D sodorisants Thetford le leader de l industrie propose deux d sodorisants pour r servoirs d eaux us es qui offre un rendement in gal pour d sodoriser nettoyer le r servoir et en dig rer les d chets Aqua Kem et EcoSmart Papier hygi nique Pour faciliter l vacuation des d chets il est recom mand d utiliser du papier hygi nique congu sp ciale ment pour se d sint grer rapidement contrairement aux papiers hygi niques m nagers tels que le papier hygi nique Aqua Soft 2 paisseurs et RV Marine 1 paisseur de Thetford 11 Garant a Para informaci n sobre los t rminos definidos de la garant a consulte la declaraci n de la garant a incluida en este paquete de informaci n Limpieza Limpie la bomba exclusivamente con productos no abrasivos ni derivados del petr leo El Aqua Clean de Thetford es un limpiador no abrasivo para todo uso que est especialmente formulado para ser inocuo en to dos los componentes del sistema de su inodoro No limpie nunca
22. marine et tre branch s ces raccords l aide de DEUX 2 COLLIERS EN ACIER INOXYDABLE VIS SANS FIN Le SERRAGE de ces COLLIERS doit tre FR QUEMMENT V RIFI afin de pr venir les fuites m Si l unit est reli e un raccord traversant la coque DES ROBINETS DE PRISE D EAU DOIVENT TRE CORRECTEMENT INSTALL S sur ces conduites Tous les robinets ou valves secondaires install es lors du raccordement de la tuyauterie interm diaire DOIVENT TRE DE PLEIN CALIBRE et FACILEMENT ACCESSIBLES aux utilisateurs des toilettes pour tre referm s Utilisez des robinets ou valves levier de plein calibre et de qualit marine Les robinets tiroir vis sont d conseill s m SIL EAU NE S COULE PAS DANS LA CUVETTE APR S AVOIR ACTIONN DEUX OU TROIS FOIS LA CHASSE D EAU celle ci a t mal install e ou est d fectueuse N utilisez pas la cuvette sanitaire tant que l installation n a pas t corrig e ou l appareil r par Veuillez consulter la section Installation ou la section D pannage de ce manuel m N utilisez QUE des accessoires de montage en ACIER INOXYDABLE NE L INSTALLEZ PAS SANS INS RER LES DOUILLES DE MONTAGE EN PLASTIQUE DANS LES TROUS Un montage incorrect de la cuvette pourra entra ner du jeu dans sa fixation ou endommager m La cuvette n est con ue que pour les d chets humains et le papier hygi nique N y jetez jamais des CORPS TRANGERS essuie tout en papier lingettes humides c
23. n trait e doit tre aliment e par le module de relais de la cuvette L utilisation d une pompe consommant plus de 15 amp res exige l installation d un contacteur relais Ne branchez pas la pompe directement la source c c pour la commander avec son interrupteur hydraulique Si une fuite devait survenir la pompe fonctionnerait continuel lement au risque de couler l embarcation et d entra ner des d c s m Pour prot ger le syst me sanitaire un filtre sur conduite DOIT tre pos L absence d un tel filtre peut annuler la garantie du produit m Une boucle de ventilation du diam tre appropri DOIT tre install e si EN TOUTE CIRCON STANCE ou dans TOUTE SITUATION y compris la g te ou la charge e La cuvette est reli e un raccord traver sant la coque et que le rebord de la cuvette POURRAIT se trouver en dessous de la ligne de flottaison Antes de comenzar la instalaci n con sidere y haga planes respecto a lo siguien te Sitio de montaje m Idealmente el inodoro EasyFit Eco debe instalarse en un sitio que est por encima del tanque de retenci n Una elevaci n de 183 cm 6 pies m xima entre el inodoro y el tanque de retenci n no afectar el rendimiento m Con el inodoro y la plantilla suministrada verifique que el lugar de instalaci n tenga las siguientes caracter sticas e La distancia entre el inodoro y la pared debe ser tal que no se tuerzan las mangueras de suministro de agua y
24. ndados por entra ner un incendie ABYC e ISO podr a dar lugar a incendios m All circuits must follow ABYC ISO standards m Tous les circuits doivent respecter les normes r m Wire gauge sizes must follow Wire Gauge Size de l ABYC ISO m Todos los circuitos deben cumplir con las normas de Chart m Le calibre des fils doit correspondre a ceux ABYC ISO losindicad m Every toilet must have its own circuit breaker indiqu s dans le Tableau de calibre des fils no ss ie SE or fuse m Chaque cuvette sanitaire doit comporter son Cada inodoro debe tener su propio interruptor m Always use crimp style connectors with Sealing propre disjoncteur ou fusible oo autom tico o fusible provisions to avoid corrosion m Utilisez syst matiquement des raccords a sentir y Utiice siempre conectores sellados a presi n para tanches pour viter la corrosion impedir la corrosi n 0 20 feet 20 32 Feet 33 50 feet Circuit Breaker 10 Gauge 30 amp 16 Gauge 14 Gauge 12 Gauge 30 amp Tableau de calibre des fils 10 1 609 6 cm 6 1 9 8 m 10 1 15 2 m Disjoncteur 0 20 pieds 20 32 pieds 33 50 pieds Calibre 10 Calibre 8 Calibre 6 30A Calibre 16 Calibre 14 Calibre 12 30A Tabla de calibre de los cables 0 50 pies 20 32 pies Interruptor autom tico 10 1 609 6 cm 6 1 9 8 m 10 1 15 2 m 30A www thetford com 3 Tecma EasyFit Owner s amp Installation Manual Harness Kit Parts Note To install the Tecma EasyFit toilet you MUST have th
25. ninguna manera esta unidad pues de hacerlo podr a ocasionar da os materiales lesiones o electrocuci n Thetford Corporation no acepta nin guna obligaci n o responsabilidad por cualquier da o al equipo lesiones o la muerte que pudieran ser causados por la instalaci n el servicio o el manejo incorrectos de este sistema Thetford Corporation recomienda que los trabajos el ctricos y de fontaner a sean realizados por personal con licen cia Se requiere el cumplimiento de los c digos y permisos locales PELIGRO Peligro de descargas el ctricas incendio e inundaciones El incumplimiento de estas advertencias puede dar lugar a p rdidas materiales lesiones y muerte a Utilice siempre el INTERRUPTOR AUTOM TICO FUSIBLE Y CABLES DEL CALIBRE RECOMENDADOS POR ABYC m Antes de comenzar a trabajar aseg rese siempre de que la ENERG A EL CTRICA est APAGADA y que las TOMAS DE MAR est n CERRADAS o en posici n DESACTIVADA m Si el inodoro est conectado a cualquier adaptador pasacasco SIEMPRE CIERRE o APAGUE TODAS LAS TOMAS DE MAR cuando SE DEJE DESATENDIDA LA EMBARCACI N incluso aunque sea por un tiempo m nimo m Para unidades que usen agua dulce que est n en cualquier momento conectadas a los sistemas municipales costeros de suministro de agua se deber DESCONECTAR el SISTEMA COSTERO si LA EMBARCACI N VAA QUEDARSE DESATENDIDA incluso aunque sea por un tiempo m nimo www thetford com Form F
26. o est dise ado para descargar desechos por una tuber a o manguera de saneamiento de 38 mm 1 1 2 pulg de calidad mar tima IMPORTANTE Utilice nica mente mangueras reforzadas de calidad mar tima para la instalaci n Tambi n se puede usar tuber a de PVC r gida para la l nea de descarga Si se usan mangueras flexibles evite los acoda mientos agudos que podr an ocasionar que la manguera se doble con consecuente restricci n del flujo afiance las mangueras para evitar la abrasi n Inspeccione siempre la instalaci n final para comprobar que no haya fugas www thetford com Dimensions Dimensions Dimensiones High Profile Profil haut Perfil alto Weight 45 Ibs Poids 20 4 kg Peso 20 4 kg Weight 45 lbs Poids 20 4 kg Peso 20 4 kg ARTOO202A x Note China base dimensions may vary Remarq Ue Les dimensions de Nota Las dimensiones de la base slightly in size la base de porcelaine peuvent varier l gere de porcelana podr an variar ligeramente Electrical System Circuit lectrique Sistema el ctrico DANGER FIRE HAZARD DANGER RISQUE D INCENDIE PELIGRO PELIGRO DE INCEN Failure to use ABYC ISO recommended N gliger d utiliser les disjoncteurs ou DIO El uso de interruptores autom ticos o circuit breakers or fuses can result in fire fusibles recommand s par l ABYC ISO peut fusibles diferentes a los recome
27. ondoms produits d hygi ne f minine soie dentaire d chets m nagers etc Advertencias cont m Sila unidad est conectada a cualquier adaptador pasacasco TODAS las mangueras flexibles que est n directa o indirectamente conectadas entre el inodoro y CUALQUIER adaptador pasacasco tienen que ser de calidad mar tima y estar conectadas a cada adaptador con DOS 2 ABRAZADERAS DE TORNILLO SIN FIN DE ACERO INOXIDABLE PARA MANGUERA Para prevenir fugas se debe COMPROBAR CON FRECUENCIA EL APRIETE DE ESTAS ABRAZADERAS m Sila unidad est conectada a cualquier adaptador pasacasco TENDR QUE HABER TOMAS DE MAR INSTALADAS DEBIDAMENTE en estas tuber as Todas las tomas de mar o las v lvulas secundarias para conexi n de tubos intermedios DEBEN SER DE PASO TOTAL y ESTAR F CILMENTE ACCESIBLES para todos los usuarios de los inodoros Utilice v lvulas y tomas de mar de calidad mar tima de paso total y activadas por palanca No deben utilizarse v lvulas de compuerta atornillables m SINO FLUYE AGUA AL INODORO DURANTE LOS PRIMEROS DOS O TRES CICLOS DE DESCARGA significa que la instalaci n es incorrecta o que el producto no funciona Suspenda el uso del inodoro hasta que se haya corregido la instalaci n o se hayan realizado las reparaciones S rvase repasar las secciones Instalaci n y Resoluci n de problemas de este manual m Utilice SOLAMENTE herrajes de montaje DE ACERO INOXIDABLE NO HAGA LA INSTALACI N S
28. onnected to a through the hull fitting and rim of toilet could EVER be in a position below the waterline Tecma EasyFit Owner s amp Installation Manual Avant d entreprendre l installation consid rez les points suivants Emplacement de montage m Id alement la cuvette EasyFit Eco doit tre install e un endroit situ au dessus du r servoir d eaux us es Une l vation maximale de 183 cm 6 pi entre la cuvette et le r servoir d eaux us es n aura pas d effet sur son fonctionnement ma l aide de la cuvette et du gabarit fourni v rifiez que le site d installation a les caract ristiques suivantes e ily a suffisamment d espace entre la cuvette et le mur pour que les tuyaux d arriv e d eau et d vacuation ne soient pas tordus e un acc s suffisant pour l entretien m Le plancher sous la cuvette est de niveau et assez solide pour supporter la cuvette et le poids de tout utilisateur potentiel m La structure du plancher est suffisamment forte pour ancrer solidement la cuvette avec les vis fournies 19 mm po minimum m Le rev tement du sol r siste l eau afin de prot ger l int grit de la structure et des fixations Consid rations relatives l eau non trait e m La pompe eau non trait e doit tre solidement fix e dans un endroit sec et bien a r Elle ne doit tre aucun moment plus de 183 cm 6 pi au dessus de la ligne de flottaison inclin e ER 1a pompe eau no
29. ontinues dripping briefly into bowl after flush cycle is complete Toilet is installed below water line with vented loop in water supply line Normal operation if only a small amount of water drips from nozzle Bowl drains dry after flush Water is siphoning out of bowl due to discharge hose pulled down Discharge hose from macerator pump is pulled down Straighten hose so that top of discharge hose is in line with toilet nozzle Hope and nozzle must be level NOTE this Troubleshooting Guide is intended to provide a basic service aid in the case of incorrect toilet operation If the suggested actions above do not resolve the issue it may be necessary to bring unit in for professional service Thetford Customer Service 1 800 521 3032 Tecma EasyFit Owner s amp Installation Manual 12 www thetford com D pannage PROBLEME CAUSE ACTION SOLUTION La cuvette ne se vide pas ou se vide mal Le r servoir d eaux us es est plein Vidangez le r servoir d eaux us es avant de r utiliser la cuvette Entr e de la pompe obstru e Eliminez l obstruction NE JETEZ PAS de corps trang ers dans la chasse d eau Objet solide dans le mac rateur COUPEZ l alimentation Essayez de retirer l objet Si vous n y arrivez pas contactez le service Thetford Tecma 1 800 521 3032 NE JETEZ PAS de corps trangers dans la chasse d eau Tension trop f
30. ormulaire Formulario No 38677 Rev B 11 18 11 Warnings Con t m these lines All seacocks or secondary valves fitted in connecting intermediate tubing MUST BE FULL BORE VALVES and READILY AC CESSIBLE to all toilet users Use lever actuated full bore marine quality seacocks and valves Screw down gate valves are not recommended IF WATER DOES NOT FLOW INTO TOILET DURING THE FIRST TWO OR THREE FLUSH CYCLES it has been improperly installed or has malfunctioned Discontinue use of toilet until installation has been corrected or repairs are made Please review this manual s Installation section or refer to the Troubleshooting section Use ONLY STAINLESS STEEL mounting hard ware DO NOT INSTALL WITHOUT PLASTIC MOUNTING HOLE INSERTS IN PLACE Failure to properly mount toilet may result in toilet becoming loose or damaged Only human waste and toilet paper should be put into the toilet Never flush FOREIGN MATE RIALS e g paper towels pre moistened wipes condoms feminine hygiene products dental floss household garbage etc Avertissements suite m raccords l aide de DEUX 2 COLLIERS EN ACIER INOXYDABLE A VIS SANS FIN Le SERRAGE de ces COLLIERS doit tre FREQUEMMENT VERIFIE afin de pr venir les fuites m Si l unit est reli e un raccord traversant la coque TOUS les tubes flexibles directement ou indirectement raccord s entre la cuvette et TOUT raccord traversant la coque doivent tre de qualit
31. r to Fig C D and E for all part references es Broca de ART00212 1 Place 6 on tracing mark position Placez 6 Colocar en el trazo marcar posici n Drill pilot holes for Percez les avant trous ins rez Hacer los orificios de gu a para Place O in permanent position trace outline Placez dans sa position permanente tracez on contour Colocar en posici n permanente trazar per metro ARTOD213 1A ART00212 2A Blue white Bleu blanc Azul Blanco O A Position connectors feed amp through wall Positionnez les connecteurs enfilez dans le mur Colocar conectores pasar 3 a trav s de la pared le trou Pasar afianzar K4 con los tornillos Attach Water Supply Fresh Water Installations refer to the Solenoid Harness and Accessory Kit instructions Raw Water Installations refer to the Pump Harness and Accessory Kit instructions Black wire Fils noir Fils rouge Cable rojo Connect to D connector then to QU Connectez au connecteur non fourni 6 puis a O Conectar O a conector luego a 5 www thetford com Rema FQUE Reportez vous aux figures C D et E pour toutes les r f rences de pi ces sur le trait marquez la position de 2 om cover hole and secure Kam ith screws l sez 5 au travers de connectez le couvrez xez K4 avec les is a trav s de O conectar a cubrir el ori
32. rceuse lectrique m M che 1 8 po Installation de la plaque Lors de la planification de l installation prenez en compte m l paisseur du mur o sera install e la plaque m La distance entre la cuvette et la plaque la longueur du faisceau de c bles est de 3 7 m 12 E DANGE RISQUE D INCENDIE A aways use recN utilisez que les disjoncteurs et fusibles recommand s pour viter tout risque d incendies Planificaci n de la instalaci n cont PELIGRO Sino se usa una v lvula antisif n en los sitios de instalaci n de la bomba de agua bruta el agua podr a fluir sifonear hacia el inodoro desde la parte ex terior de la embarcaci n con consecuentes posibles da os materiales y muertes Herramientas requeridas m Serrucho de calar de 32 mm 1 1 4 pulg m Serrucho de calar o sierra de vaiv n de 89 mm 3 1 2 pulg m Dado y trinquete de 7 16 pulg o llave de 7 16 pulg m Taladro el ctrico m Broca de 1 8 pulg Instalaci n del marco Al hacer los planes de instalaci n recuerde tomar en cuenta m El espesor de la pared de colocaci n del marco m La distancia entre el inodoro y el marco el arn s tiene una longitud de 3 7 m 12 pies PELIGRO DE INCENDIO ut lice siempre los disyuntores el ctricos y fusibles recomendados Failure to follow the recommenda tions can result in fire Bezel Specifications Caract ristiques de la plaque Especificaciones del marco
33. tallation a eau non trait e Boucle de ventilation d au moins 19 mm 3 4 po de diam tre si n cessaire Installation a eau non trait e Conduite d arriv e d eau de 13 mm 1 2 po de diam tre Installation eau douce Boucle de ventilation d au moins 38 mm 1 1 2 po de diam tre si n cessaire Tuyau d vacuation pour bateau de 38 mm 1 1 2 po de diam tre Raccord droit ou coude de 90 de 38 mm 1 1 2 po si n cessaire Tube de silicone blanc ou transparent Connecteurs lectriques vari s 38671 38679 38681 38682 38679 38682 oniy 38679 38682 uniquement 38679 38682 nicamente Filtro interno si corresponde Tuber a de suministro de agua de 19 mm 3 4 pulg de di metro Instalaci n de agua bruta V lvula antisif n de 19 mm 3 4 pulg de di metro m n si se requiere Instalaci n de agua bruta Tuber a de suministro de agua de 13 mm 1 2 pulg de di metro Instalaci n de agua dulce V lvula antisif n de 38 mm 1 1 2 pulg de di metro min si se requiere Manguera de descarga de calidad mar tima de 38 mm 1 1 2 pulg de di metro Acoplador recto o de 90 de 38 mm 1 1 2 pulg seg n se requiera Masilla de silicona blanca o transparente Conectores el ctricos varios www thetford com Orientation Apercu Orientaci n IF NEEDED 8 above waterline ALL TIMES SI NECESSAIRE 20 cm au dessus de la ligne de flottaison EN TOUT T
34. todo de instalaci n 2 Run assemble parts as shown 2 Enfilez assemblez les pi cestel 2 Pasar qu illustr 3 Tighten 1 1 Pto secure in armar las piezas Como se muestra place 3 Serrez le collier non fourni Oue 3 Apretar de 63 5 mm 2 1 2 pulg 63 5 mm 2 1 2 p en place Essayez la cuvette Comprobar el funcionamiento del inodoro BEFORE permanently attaching the toilet m Flush the toilet to check toilet operation m Verify no leaks correct as needed m Permanently insert and into wall AVANT de fixer la cuvette en permanence Actionnez la chasse d eau pour v rifier son fonctionnement Assurez vous qu il n y a aucune fuite corrigez sil y a lieu Ins rez d finitivement lt a et 5 dans le mur ANTES de fijar el inodoro de forma permanente m Descargar el inodoro para comprobar su fun cionamiento m Verificar que no tenga fugas y hacer las cor recciones necesarias m Insertar lt a y 5 permanentemente en la pared 0 pour fixer le tout para afianzar Calfeutrez le long de l int rieur de la ligne trac e Aplicar un compuesto de calafateo alrededor de la Tinea insert into floor secure ins rez dans le plancher fixez insertar en el piso afianzar Caulk around O base Calfeutrez autour de la base de o un compuesto de calafateo alrededor de la base Caution seal with silicone or latex base sealant Do not use Polysulfide base
35. ula antisifon del di metro adecuado si EN CUALQUIER CIRCUNSTANCIA o CONDICI N incluidas situaciones de escora carga o arrumaje El inodoro est conectado a un adaptador pasacasco y el reborde del inodoro podr a EN CUALQUIER MOMENTO quedar por debajo de la l nea de flotaci n www thetford com Installation Planning Con t DANGER Failure to use a Vented Aion in raw water pump installation sites can lead to water flowing into the toilet from the outside siphoning which can cause loss of property and life Required Tools 1 1 4 hole saw 1 3 4 2 hole saw 3 1 2 hole saw 7 16 socket and ratchet or 7 16 wrench Electric drill 1 8 drill bit Bezel Installation When planning the installation be sure to consider m Bezel placement wall thickness m Distance between toilet and bezel the har ness is 12 in length DANGER HAZARD OF FIRE Always use recommended circuit break ers or fuses Failure to follow the recommenda tions can result in fire Fig F Planification de l installation suite DANGER N gliger de poser une boucle de ventilation dans une installation a eau non trait e risque de siphonner l eau de l ext rieur vers la cuvette et d entra ner des pertes de vie et pertes mat rielles Outils requis m Scie emporte pi ce de 32 mm 1 1 4 po m Scie emporte pi ce de 89 mm 3 1 2 po ou scie sauteuse m Cl cliquets et douille 7 16 po ou cl 7116 po m Pe
36. ure Colocar 6 ubicar posici n H hacer orificio DANGER Failure to use a Vented Loop in raw water pump installation sites can lead to water flowing into the toilet from the outside siphoning which can cause loss of property and life Refer to Installation Planning Raw Water Considerations to determine if a Vented Loop is needed DANGER N gliger de poser une boucle de ventilation dans une installation a eau non trait e risque de siphonner l eau de l ext rieur vers la cuvette et d entra ner des pertes de vie et pertes mat rielles Reportez vous la section Planification de l installation Consid rations relatives l eau non trait e pour d terminer si une boucle de ventilation est n cessaire PELIGRO sino se usa una v lvula antisif n en los sitios de instalaci n de la bomba de agua bruta el agua podr a fluir sifonear hacia el inodoro desde la parte exterior de la embarcaci n con consecuentes posibles da os materiales y muertes Refer to Installation Planning Raw Water Considerations to determine if a Vented Loop is needed Tecma EasyFit Owner s amp Installation Manual Installation suite ARTO0201 1a Vertical Installation Installation verticale Instalaci n vertical Instalaci n cont ARTO0201 2a_ Horizontal Installation Installation horizontale Instalaci n horizontal 1 Choose installation method 1 Choisissez la m thode d installation 1 Elegir el m