Home

AS-Interface protocol BUSLINK-Generation C

image

Contents

1. adressage Signaux de gt e e v0 0 vo 2 vVo 4 Vo 6 V1 0 V1 2 v1 4 v1 6 commande Signaux SEENEN TEETER de rappel i EP 18r noeud 2eMe noeud E Distributeurs bistables maxi 4 ak le poids des adresses progresse du haut en bas puis de la WE gauche vers la droite KD Position des dE distributeurs WG Gg X 112 3 4 adressage V0 2 V0 4 V0 6 lt commande 14 e II I os V0 1 V0 3 V0 5 V0 7 lt Signaux de TE rappel 12 18 noeud 2 ME noeud Signaux de E NOTA en configuration 2 noeuds il est possible de panacher des distributeurs monostables et des bistables maxi 4 mono et SR ER 2 bistables Ceux ci sont toujours dispos s comme ci contre Dans ce cas la progression d adressage est la suivante Position des distributeurs 1 2 3 4 5 6 R p adressage V0 0 V0 2 V0 4 V0 6 V1 0 V1 2 a V1 1 V1 3 4 monostables 2 bistables 1er noeud 2eMe noeud 191 noeud 2eme noeud 4 5 2 ADRESSAGE DES ENTREES llot AS Interface avec entr es IN1 3 wie 18r noeud IN1 4 ame DT l 2eme noeud ere eE Raccorder 2 capteurs 2 entr es par connecteur M12 voir page pr c dente ASTO 14 JOUCOMATIC INSTALLATION
2. 1 LE SYSTEME BUSLINK G n ration C avec protocole AS Interface Ensemble constitu d ilots de 4 8 distributeurs pneumatiques commande monostable ou bistable M5 G1 8 G1 4 a connectique int gr e pr vue pour raccordement avec automate programmable API par liaison s rie bus de terrain via le protocole de communication normalis AS Interface N 21401 4 Distributeurs nombre maxi 8 monostables ou 4 bistables 2 Module boitier de connexion AS Interface 8 Sur demande 4 ou 8 entr es NOTA Pas de modules d entr es ou sorties suppl mentaires SCHEMA TYPE Maitre Alimentation AS Interface eos AS Interface Cable jaune f ae 24V K SS C ble noir Passerelle AS Interface vers d autres protocoles Profibus DP FIPIO Device NET AVANTAGES Par l tendue de ses possibilit s le syst me BUSLINK r pond aux besoins modernes d installations automatis es e Suppression des faisceaux de fils encombrants e Economie de temps et de co t des c blages lectrique et pneumatique e Ensemble livr test quip des distributeurs e Maintenance facilit e ENSEMBLES REALISABLES Possibilit de constituer des ensembles Buslink compos s e D lots de 4 6 ou 8 distributeurs monostables 3 2 ou 5 2 ou 4 distributeurs bistables 5 2 5 3 ou 4 distributeurs 2x3 2 e D lots de tailles diff rentes pour distributeurs s ries 569 570 571 u
3. n ets ee Maitre Alimentation e Ensemble livr test quip des distributeurs AS Interface Cable jaune AS Interface C ble noir ENSEMBLES REALISABLES Possibilit de constituer des ensembles Buslink compos s de ccm 7 Distributeurs 3 2 2x3 2 5 2 ou 5 3 s ries 569 M5 ou coupleurs asi leif ol TTT oH are 570 G1 8 ou coupleurs 571 G1 4 Ps E OPTIONS nous consulter I Passerelle AS Interface vers d autres protocoles Profibus DP FIPIO Device NET e Alimentation pneumatique par 2 pressions diff rentes e Alimentation pneumatique externe des pilotes CARACTERISTIQUES DE COMMUNICATION AS Interface mode bidirectionnel c ble plat AS Interface jaune 2 fils optionnelle suivant les recommandations AS Interface 81 noeuds 1 lot peut comprendre 2 noeuds 4 8 distributeurs 8 entr es 100 m 300 m avec r p teur par maitre AS Interface pas de modification des programmes existants divers Protocole Support de transmission Structure du bus Nombre maxi d ensembles Nombre de distributeurs par ensemble Nombre maxi d entr es Longueur maxi du c ble bus Adressage des ensembles abonn s Harmonisation optimale avec automates Automates compatibles CARACTERISTIQUES ELECTRIQUES Tension d alimentation Taux d ondulation maxi Consommation Classe d isolation bobines Degr de protection Isolem
4. oy t2 Bleu Alimentation pb C ble AS Interface noir x Adaptateur pour connecteur AS Interface Cet adaptateur est fourni avec I ilot NOTA Lors de la connexion sur I ilot respecter le sens de montage du cable et de l adaptateur pour ce dernier d trompage par largeurs diff rentes des pattes lat rales 5 4 MISE EN SERVICE DU RESEAU AS Interface 1 Connecter le cable jaune 2 Connecter le cable noir 3 Mettre en route le maitre AS Interface 5 5 DIAGNOSTIC 5 5 1 LED DE VISUALISATION SUR LE MODULE BUSLINK Le module Buslink AS Interface dispose de 2 6 ou 10 LED de diagnostic suivant les versions e AS Interface vert S allume lorsque la communication est possible e POWER vert S allume lorsque le 24V du cable noir des distributeurs est pr sent e IN1 1 IN1 4 4 led lot 1 noeud avec 4 entr es qui s allument lorsque les capteurs sont actionn s e IN1 1 IN2 4 8 led lot 2 noeuds avec 8 entr es qui s allument lorsque les capteurs sont actionn s 5 5 2 REGISTRE DIAGNOSTIC Voir info AS Interface 5 5 3 POSITION DE REPLI Les lots AS Interface ont une position de repli z ro 5 6 FUSIBLES L alimentation en tension par le c ble noir est prot g e par un fusible int gr dans le bo tier du module bus On peut le remplacer en d vissant le couvercle du bo tier du module Otez le avec une pince mince N utilisez que des fusibles du m me type et de l
5. 4 5 3 RECAPITULATIF DES ADRESSAGES E ilot AS Interface 1 noeud 4 distributeurs monostables r f rence lot A1 4 distributeurs monostables et 4 entr es r f rence lot A2 E ilot AS Interface 2 noeuds 8 distributeurs monostables ou 4 bistables r f rence lot A3 Num ro de noeud 1121341567 H cH 1 zry 8 Bit de donn e BUSLINK AS Interface Adressage Distributeurs Entr es DO Distributeur n 1 14 VO 0 Entr e 1 IN1 1 D1 Distributeur n 2 14 VO 2 Entr e 2 IN1 2 D2 Distributeur n 3 14 VO 4 Entr e 3 IN1 3 D3 Distributeur n 4 14 VO 6 Entr e 4 IN1 4 8 distributeurs monostables ou 4 bistables et 8 entr es r f rence lot A4 Adressage distributeurs Adressage entr es de donn e 8 distributeurs monostables 4 distributeurs bistables 4 distributeurs monostables et 2 distributeurs bistables 4 entr es 8 entr es DO Distributeur 1 14 VO 0 Distributeur 1 14 VO 0 Distributeur 1 14 VO 0 Entr e 1 IN1 1 Entr e 1 IN1 1 D1 Distributeur 2 14 Vo 2 Distributeur 1 12 Vo i Distributeur 2 14 Vo 2 Entr e 2 IN1 2 Entr e 2 IN1 2 D2 Distributeur 3 14 VO 4 Distributeur 2 14 V0 2 Distributeur 3 14 V0 4 Entr e 3 IN1 3 Entr e 3 IN1 3 D3 Distri
6. B et sur demande de 2 ou 4 embases de connexion M12 5 broches femelles pour les entr es A Pour effectuer les connexions il est n cessaire d approvisionnerles c bles et connecteurs M12 compl mentaires Circuit de protection lectrique int gr pour chaque bobine Mise a la terre La mise la terre pour la protection des personnes est r aliser directement sur l ilot en raccordant la vis pr vue a cet effet Bobine i Coil Spule y oO 4 2 ALIMENTATION EN TENSION Le cable jaune alimente l interface AS Interface Le cable noir alimente les distributeurs et les entr es Tension d alimentation 24 V 10 Ondulation r siduelle 10 Consommation 1 7 par bobine 0 2 W par LED maxi 5 W lectronique bus Entr es courant cumul lt 0 5 A Calcul de la puissance absorb e voir ci dessous V rifier la tension d alimentation pendant que l installation est en service et s assurer que les tol rances admissibles sont respect es 10 4 3 CALCUL DE LA PUISSANCE ABSORBEE La puissance absorb e d un lot d pend de sa configuration Le calcul de cette puissance permettra l utilisateur d optimiser la d finition de l alimentation 24 V n cessaire Consommation des divers l ments Consommation de l lectronique Bus 40 mA Consommation d une entr e 9mA Consommation d un distributeur led 79 mA ASTO 12 JOUCOMATIC INSTALLATION BUSLINK AS
7. Diff rentiel 3 570 G1 8 570 00 103 pneumatique 2 569 M5 569 00 012 Diff rentiel 3 570 G1 8 570 00 012 4 571 G1 4 571 00 012 Electro pneumatique 2 569 M5 569 00 014 3 570 G1 8 570 00 014 4 571 G1 4 571 00 014 Electro Electro pneumatique pneumatique m e 2 569 M5 569 00 016 3 570 G1 8 570 00 016 lectropneumatiques 4 571 G1 4 571 00 016 commandes Centre ouvert la presion 2 569 569 00 018 P 570 570 00 018 lectropneumatiques 4 571 571 00 018 Centre ouvert l chappement 569 00 020 We 570 00 020 commandes lectropneumatiques 571 00 020 Possibilit d utiliser les distributeurs 5 2 en fonction 3 2 NF en obturant l orifice 2 ou 3 2 NO en obturant l orifice 4 1 Les fonctions de la nouvelle construction a double pilotes int gr s restent identiques a la version classique La symbolisation reste conforme a ISO 1219 1 NOTA Toutes les versions ci dessus peuvent tre mont es et combin es sur le m me ilot dans une m me taille ASTO JOUCOMATIC BUSLINK AS Interface INSTALLATION 3 MONTAGE DU BUSLINK G n ration C avec AS Interface 3 1 FIXATION Effectuer la fixation de l lot voir chapitre 2 3 S assurer lors du montage qu il y ait suffisamment de place pour le c blage les connecteurs et les ventuels silencieux d chap pement Puis proc der au raccordement pneumatique et lectrique Alimentation pression 1 e
8. PG11 Mw KS PG be A JES eel RICA fr RES ERS H ER 4 6mm p 60 cj 63 _ ASTO 20 JOUCOMATIC K
9. gy not necessary no coil 12 differential return 24V Signal to coil 14 pilot gy E BISTABLE 5 2 SPOOL VALVE Type J Port 2 Port 4 These signals can be pulsed or maintained until change of status Signal to coil 12 return Signal to coil 14 pilot E 5 3 SPOOL VALVES Types B E G o U Port 2 _ E L Port 4 i ti Signal to coil 12 H ER H_ 24 V OV i Oo Signal to coil14 In the 5 3 pressure held version type W1 the pressure at ports 2 and 4 is that which existed when coils 12 and 14 were deenergized ASCO 16 JOUCOMATIC K INSTALLATION BUSLINK AS Interface m MONOSTABLE 3 2 SPOOL VALVE SERIES 570 NC Type Z 12 2 NE D 1 Port 2 Take signal 14 for the addressing and 24V pilot connection of the 3 2 spool valves Coil 12 x OV NC into account m MONOSTABLE OR BISTABLE 5 2 SPOOL VALVE OPERATED IN 3 2 NC FUNCTION block port 2 MONOSTABLE BISTABLE P Pot2 Blocked Blocked P Port 4 0 24 f 24 V Signal to coil 12 not necessary differential return OV OV 24 V OV 24 Signal to coil 14 OV mM MONOSTABLE OR BISTABLE 5 2 SPOOL VALVE OPERATED IN 3 2 NO FUNCTION block port 4 MONOSTABLE BISTABLE Port 2 o U P Port 4 A Blocked Blocked Signal to coil 12 SNT hot necessary differential return ae a OVF OV Signal to coil 14 PA D 24V CM OV OV ASTA 17 JOUCOMATIC BUSLIN
10. 1 NOTE Only one valve size per island ASUS JOUCOMATIC K BUSLINK AS Interface INSTALLATION 3 ASSEMBLY OF BUSLINK Generation C with AS Interface 3 1 MOUNTING Mount the island as described in chapter 2 3 Make sure to provide for enough room for the cables connectors and optional exhaust silencers Proceed with pneumatic and electrical connection Pressure supply 1 and exhausts 3 5 Operating ports 2 4 Bus connection yellow cable 24VDC power supply to valves black cable OOO Sensor inputs upon request 3 2 PNEUMATIC CONNECTION 3 2 1 GENERAL E To subbase The lines for the following common pneumatic signals are collected in the subbase supply pressure 1 exhausts 3 and 5 and pilot valve exhaust The connecting ports are either on the right side or in some versions on the left side of the subbase see below E To spool valves Two connection possibilities for operating ports 2 4 on top side Threaded connection directly on the spool valve body With instant fittings for flexible hose for valve series 569 and 570 Connecting instructions Remove all protective plastic caps Insert the gasket which generally comes with the M5 connectors or banjo type screw fittings Screw down the connectors and screw fittings correctly Screw in the exhaust silencers Connect the pneumatic piping Gather the tubes in order to have neat and accessible piping E Rec
11. E Connection of supply voltage to island brown oy t2 blue Power supply 0 Black AS Interface cable x Adapter for AS Interface connector This adapter is supplied with the island NOTE When connecting the cable to the island please observe the mounting direction of the cable and adapter mounting direction of adapter secured by differently sized side pieces 5 4 STARTUP OF AS Interface NETWORK 1 Connect the yellow cable 2 Connect the black cable 3 Power on the AS Interface master 5 5 DIAGNOSTICS 5 5 1 LED INDICATIONS ON THE BUSLINK MODULE The Buslink AS Interface module is provided with 2 6 or 10 diagnostic LEDS according to the version e AS Interface green lights up as soon as data exchange is possible e POWER green lights up to indicate correct 24 V power supply through the black cable to the valves e IN1 1 IN1 4 4 LEDs 1 node island with 4 inputs light up as soon as the sensors are activated e IN1 1 IN2 4 8 LEDs 2 node island with 8 inputs light up as soon as the sensors are activated 5 5 2 DIAGNOSTICS REGISTER See AS Interface information 5 5 3 RESET POSITION AS Interface islands are provided with a reset into zero position 5 6 FUSES The power supply by the black cable is protected with a fuse enclosed in the bus module housing Replace the fuse by unscrewing the lid of the module housing Remove the fuse with a thin pai
12. NC Differential return Connection Gaz thread M 5 2 Solenoid air operated pilot NPT thread Differential return instant fittings metric 5 2 Solenoid air operated Position J pilot and return top side a G an na Acca 5 3 Pressure held W1 Connection G Solenoid air operated pilot G Gaz thread 4 2 N ier hred B aN T ike 5 3 Pressure applied W2 oo SAS i Solenoid air operated pilot Position ao E an Pee 5 3 Exhaust released W3 lateral P syts Solenoid air operated pilot Al 1 For detailed information on spool valves see chapter 2 1 Number of spool valve 1 places on the island ORDERING EXAMPLE Reference CEBI00A4 CP300Q0G106 KKMMJJ BUSLINK valve island Generation C AS Interface protocol with 2 nodes 8 outputs and 8 inputs over 4 M12 connectors lsland for 6 spool valves series 570 with outputs and instant fitting for flexible hose OD 6 mm equipped as follows Positions nos 1 and 2 2 monostable 3 2 spool valves NC type K Positions nos 3 and 4 2 monostable 5 2 spool valves type M Positions nos 5 and 6 2 bistable 5 2 spool valves type J NOTE In this configuration the bistable spool valves are always to be placed on the right hand side of the island ACCESSORIES see page 20 nee JOUCOMATIC K BUSLINK AS Interface INSTALLATION 2 5 MANUAL OVERRIDE Spool valves series 569 570 571 are equipped with manual A override by impulse A monostable spool val
13. Nombre maxi de distri Nombre maxi noeud s buteurs d entr es 2 2 IMPLANTATION DES COMPOSANTS Description Embase de raccordement pneumatique de l lot Buslink Module de connexion du Bus AS Interface Distributeurs 3 2 2x3 2 5 2 5 3 monostables ou bistables 8 maxi Raccordement taraud ou a coupleurs des orifices d utilisation 2 4 partie sup rieure Raccordement taraud d alimentation pneumatique 1 et des chappements 3 5 Bride de raccordement d alimentation pour lot de 8 distributeurs voir page 11 LED de visualisation de la mise sous tension des pilotes AS Interface adaptateur pour c ble du bus AS Interface jaune OI ICO AS Interface adaptateur pour c ble d alimentation AS Interface suppl mentaire noir oO R glage de l adresse 2 LED de visualisation de AS Interface et alimentation 8 LED de visualisation des entr es Raccordement des entr es par connecteurs M12 sur demande Echappement des pilotes 82 84 collect et raccordable OM5 ASTOA JOUCOMATIC BUSLINK AS Interface INSTALLATION 2 3 ENCOMBREMENTS FIXATION CLEA L lot de distribution comprend 4 trous de fixation principale sur l embase des distributeurs compl t
14. OT Ta Switch Node 3 Program the address for the 1st node or increment f position number or decrement with the hand held programmer and press write 4 Set the switch into position 3 5 Set the address for the 2nd node or increment or decrement with the hand held programmer and press write 6 Set the switch into position 2 7 The 2 addresses are saved in the island memory Remount the threaded plug 5 2 2 SETTING OF THE TRANSMISSION SPEED The transmission speed is fixed and preset by the AS Interface master 5 2 3 CONTROLLER CARD CONFIGURATION WITH THE ISLANDS In case the AS Interface network is configured with the AS Interface coupler which is integrated in the PLC the identification codes for a JOUCOMATIC AS Interface island are as follows Code inputs outputs Identificator code of JOUCOMATIC island 7 ASCO 18 JOUCOMATIC K INSTALLATION BUSLINK AS Interface 5 3 CONNECTION OF SUPPLY VOLTAGE The supply voltage is connected after having carried out all programming instructions see preceding chapters The operating voltage is connected to the front of the island with the black profiled AS Interface cable and the vampire type connector provided for instant connection of the cable to the island with a clip on adapter see below No screw or stripping of cable ends is required Connection to supply unit
15. a BUSLINK spool valve island generation C define the weight of the pneumatic components from the spool valve series and number of valves required see above table the weight of the bus connection module with or without inputs ASTO 6 JOUCOMATIC K INSTALLATION BUSLINK AS Interface 2 4 ORDERING INFORMATION FOR A BUSLINK VALVE ISLAND GENERATION C WITH AS Interface When ordering please specify the electrical compontents 1 the pneumatic components 2 and the optional accessories separately E Electrical components OPTION without option other options An island can be equipped with two or four M12 connectors A for connection of four or eight input sensors as shown in the table opposite Input Output number 1 node 4 outputs 1 node 4 outputs 4 inputs 2 node 8 outputs 2 node 8 outputs 8 inputs Number of positions t bistable alee or 4 to 8 monostable valves 1 _ Spool valve t series and size i 569 OME or instant tings Type Spool valve functions oe Eri RATES A Blanking plates for electr pneum mounting surface l OPTIONS Z Eal F M 3 2 NC Solenoid air operated pilot without fe Spring Differential return other options K SA 2x Solenoid air operated pilot t 8 2
16. ae A 7 7 Vo 0 vo 2 Vo 4 vo 6 lt Pilot signals 14 V0 1 V0 3 V0 5 V0 7 Return signals ce D ist node 2nd node E NOTE In 2 node configuration it is possible to mix monostable and bistable valves max configuration 4 monostable valves and 2 bistable EE ee valves These are always placed as shown opposite In this case the addressing priority is as follows Valve position 1 2 3 4 5 6 i 7 Adressing V0 0 VO 2 V0 4 V0 6 V1 0 V1 2 wy V1 1 V1 3 4 monostable 2 bistable valves 1st node 2nd node valves 2nd node 1st node 4 5 2 INPUT ADDRESSING AS Interface island with inputs X IN1 2 1st node Mens 2nd node ro e 6 Connect 2 sensors 2 inputs for each M12 connector see previous page ASTD 14 JOUCOMATIC K INSTALLATION BUSLINK AS Interface 4 5 3 ADDRESSING SUMMARY E AS Interface island with 1 node 4 monostable valves Island reference A1 Data bit Addressing Valves Inputs Do Valve no 1 14 Input 1 V0 0 IN1 1 Valve no 2 14 Input 2 4 monostable valves and 4 inputs D1 v0 2 IN1 2 Island reference A2 Valve no 3 14 Input 3 V0 4 IN1 3 Valve no 4 14 Input 4 V0 6 IN1 4 D2 D3 E AS Interface island with 2 nodes 8 monostable valves or 4 bistable valves 8
17. alloy and acetal resin POM Sealings in nitrile NBR 570 spool valve 2 x 3 2 2 2 PILOT VALVE Sealings in nitrile NBR B m Electrical equipment in compliance with standard NF C79300 ii Coil and iron circuit encapsulated in epoxy resin gt Impulse manual override A Bistable 30 3A spool valve ELECTRICAL SPECIFICATIONS 570 spool valve 5 2 VOLTAGE 24V DC 10 max ripple ratio 10 7 CONSUMPTION 1 7 W per coil wrm INSULATION CLASS ME A A PROTECTION IP 65 CHOICE OF EQUIPMENT Operators Flow VALVE at 6 bar CODES 2 4 I min 24 VDC Symbols 1 Functions Pilot Return 14 12 Instant fitting for flexible Solenoid Spring hose O D 6 mm air Differential 570 00 053 400 G1 8 570 00 051 e Differential G1 8 570 00 103 P M5 569 00 012 Solenoid Differential G1 8 570 00 012 ar G1 4 571 00 012 M5 569 00 014 G1 8 570 00 014 G1 4 571 00 014 Solenoid Solenoid air air Pressure held M5 569 00 016 Wi G1 8 570 00 016 solenoid air G1 4 571 00 016 Pressure applied M5 569 00 018 W2 570 00 018 solenoid air 571 00 018 Exhaust released 569 00 020 W3 570 00 020 solenoid air 571 00 020 The 5 2 spool valves can be used in function 3 2 NC by plugging port 2 or 3 2 NO by plugging port 4 1 The function of push pull pilot valves corresponds to the function of conventional valves Marking to ISO 1219
18. e d une ventuelle fixation de maintien du module de connexion l aide de 2 trous dans l querre lat rale gauche L entraxe de fixation L2 volue en fonction du nombre et de la taille des distributeurs Longueur totale de I ilot L2 77 S assurer lors du montage qu il y ait suffisamment de place droite pour le raccordement pneumatique et 1 les ventuels silencieux d chappement f 28 5 4 F 5 66 5 ot L2 5 5 L2 S rie n2 nombre de distributeurs distributeurs 4 6 8 569 M5 91 5 123 5 155 5 570 G1 8 105 143 181 571 G1 4 126 5 172 5 218 5 1 BUSLINK AS Interface sans entr e hauteur n cessaire au c blage pneumatique par tubes rilsan les c bles AS Interface tant plac s horizontalement 2 BUSLINK AS Interface avec entr es hauteur n cessaire au raccordement lectrique par connecteurs M12 et c bles de liaison MASSES Masse Buslink sans module bus kg S rie n2 nombre de distributeurs distributeurs 569 570 3 2 570 5 2 5 3 571 Masse du module de connexion du bus sans entr e 0 550 kg avec entr es 0 600 kg Masse totale d un flot BUSLINK G n ration C d finir la masse de la partie lectropneumatique en fonction de la s rie et du nombre de distributeurs voir tableau ci dessus la masse du module de connexion du bus avec ou sans entr
19. female panel connector M12 earthing screw on the pneumatic subbase in accordance with the EU directive EMC 89 336 EEC CE identification air or neutral gas filtered at 30 um lubricated or not 1 5 to 8 bar 2 5 to 8 bar with 3 2 NO spool valves and series 569 functions 5 3 175 l min 600 l min 3 2 400 l min 2x3 2 550 l min 1050 l min 5 C to 50 C ASTO JOUCOMATIC K INSTALLATION BUSLINK AS Interface 2 SYSTEM COMPONENTS 2 1 FUNCTIONAL DESCRIPTION The spool valve islands are connected to a PLC with a yellow AS Interface bus cable to pilot the spool valves and detect the sensor status if the island is provided with inputs A second adapter is used to supply the valves with power black cable The pressure supply and exhaust are collected in the pneumatic subbase The spool valves ensure the pressure supply and exhaust of the pneumatic actuators The pneumatic connection of the actuators is made on the top side of the spool valves The island can be equipped with inputs upon request The electrical sensors are connected to the input modules with male connectors M12 MAXIMUM CAPACITY OF THE SPOOL VALVE ISLAND According to the configuration you choose the islands can be equipped with a maximum of 8 inputs and 8 outputs 1 output 1 spool valve pilot The maximum capacity of the island depends on the number of nodes see table below Example for maximum configuration NOTE Maximum confi
20. inputs 2 inputs for each connector Input addressing x IN1 1 IN1 3 X 1 1N1 2 IN1 4 see chapter 4 5 CONNECTION WITH M12 CONNECTOR The two following M12 connector types are recommended Straight duo connector A for the connection of 2 separate cables one for each sensor Straight mono connector B for the connection of a sensor or cable bundle Sensor Sensor Sensor Sensor sa aan Sensor BUSLINK AS Interface Island provided with four M12 panel connectors for 8 inputs 2 inputs for each connector X gt IN1 1 IN1 3 IN2 1 IN2 3 X 1 IN1 2 IN1 4 IN2 2 IN2 4 see chapter 4 5 Connectors to be supplied separately A Straight 5 pin male duo connector M12 cable feed throughs of 3 to 5 mm dia for each cable code 881 00 253 B Straight 5 pin male mono connector L A 881 00 253 8768100990 M12 for 1 cable feed through of 4 to 6 mm dia code 881 00 330 7 7 7 7 Wiring diagram of inputs View from screw side of male connector e Sensors with 2 wires e Sensors with 3 wires magnetoresistive example 24V 24V 24V 24V Sensor x Sensor IN x IN x 1 Sensor x x 1 J GND GND 7 NOTE Description Supply of inputs Input positive logic x 1 Common
21. lectropneumatique Type de raccordement LITE 3 2 NF Rappel diff rentiel x Orifices taraud s Gaz DE y Orifices taraud s NPT M SNE 5 2 C lectropneumatique g Q coupleurs m trique LoS Rappel diff rentiel En 4 2 ue Emplacement J ll 5 2 C et rappel 0 Surle dessus 1 LE lectropneumatiques 4 2 e oT TRE 5 3 Centre ferm W1 1 Type de raccordement Frs Cs lectropneumatiques 9 G Orifices taraud s Gaz AL T Hurt B AUTRE 5 3 Centre ouvert la pression W2 i Emplacement R C s lectropneumatiques O A L 4 2 a T lat ral E BU IR 1 5 3 Centre ouvert l chappement W3 2 e cect Cs lectropneumatiques ta Nombre d emplacements 1 A d finir en fonction des distributeurs des entr es de distributeurs par iot 1 et sorties supppl mentaires voir chapitre 2 1 EXEMPLE DE COMMANDE R f rence CEBI00A4 CP300Q0G106 KKMMJJ llot BUSLINK G n ration C protocole AS Interface avec 2 noeuds 8 sorties et 8 entr es par 4 connecteurs M12 Ensemble pr vu pour 6 emplacements de distributeurs s rie 570 sorties par coupleurs pour tubes souples 6 mm ext avec les mod les suivants Positions n 1 et 2 2 distributeurs 3 2 NF monostables type K Positions n 3 et 4 2 distributeurs 5 2 monostables type M Positions n 5 et 6 2 distributeurs 5 2 bistables type J NOTA Dans cette configuration les distributeurs bistables sont toujours placer droite sur l ilot ACCESSOIRES voir
22. 2 Rappel OV Signal sur bobine 14 Commande oV E DISTRIBUTEUR 5 3 Types B E G Orifice 2 Orifice 4 j _ PRESS Signal sur bobine 12 H ER H_ 24 V OV i Signal sur bobine 14 2 En version 5 3 centre ferm type W1 les pressions en 2 et 4 sont celles qui taient pr sentes au moment de la mise hors tension des bobines 12 et 14 ASTOA 16 JOUCOMATIC K INSTALLATION BUSLINK AS Interface m DISTRIBUTEUR 570 3 2 NF MONOSTABLE Type Z 12 2 L 3 1 Orifice 2 x Consid rer le signal 14 pour l adressage et le raccordement de la commande des 24V ae bobine 12 x distributeurs 3 2 NF OV m DISTRIBUTEUR 5 2 MONOSTABLE OU BISTABLE UTILIS EN 3 2 NF obturer l orifice 2 MONOSTABLE BISTABLE ie P Orifice 2 oL Obtur Obtur Orifice 4 24V 24V Signal sur bobine 12 non n cessaire rappel diff rentiel ov OV 24 V OV Signal bobine 14 ignal sur bobine g ov E DISTRIBUTEUR 5 2 MONOSTABLE OU BISTABLE UTILIS EN 3 2 NO obturer l orifice 4 MONOSTABLE BISTABLE Orifice 2 o U 7 P Orifice 4 i Obtur Obtur Signal sur bobine 12 ENT non n cessaire rappel diff rentiel he os OVF OV Signal sur bobine 14 il ee OV OV ASTO 17 JOUCOMATIC BUSLINK AS Interface INSTALLATION 5 RESEAU AS Interface 5 1 RACCORDEMENT DU BUS AS Interface La face avant de I ilot de distributeurs pneumatiques pr vu pour AS Interface est quip e d u
23. ERTISSEMENT Pour le bon fonctionnement des lots de distributeurs pneumatiques veillez ce que e l adressage soit correctement param tr e toutes interventions d installation de r glage et de maintenance doivent tre r alis es par un personnel comp tent Conform ment la directive CEE 89 392 CEE Annexe Il B une D claration d incorporation peut tre fournie sur demande Veuillez nous indiquer le num ro d accus de r ception AR et les r f rences ou codes des produits concern s Ce produit est conforme aux exigences essentielles de la Directive 89 336 CEE sur la Compatibilit Electromagn tique et amendements Une d claration de conformit peut tre fournie sur simple demande NOTE Les informations contenues dans le pr sent manuel sont susceptibles d tre modifi es sans pr avis ASCO JOUCOMATIC ne peut tre tenu responsable des omissions techniques ou r dactionnelles ni des dommages accidentels ou cons cutifs la fourniture ou l utilisation du pr sent document LE PRESENT MANUEL CONTIENT DES INFORMATIONS PROTEGEES PAR COPYRIGHT AUCUNE PARTIE DU PRESENT DOCUMENT NE PEUT ETRE PHOTOCOPIEE OU REPRODUITE SOUS QUELQUE FORME QUE CE SOIT SANS AUTORISATION ECRITE PREALABLE DE JOUCOMATIC COPYRIGHT 1999 2000 ASCO JOUCOMATIC Tous droits r serv s ASTO 2 JOUCOMATIC INSTALLATION BUSLINK AS Interface
24. Interface 4 4 RACCORDEMENT DES ENTREES Entr es sur demande Raccordement par connecteurs M12 d brochables IP65 Possibilit de raccorder des capteurs a 2 ou 3 fils Equip de 4 embases de connexion M12 pour 8 entr es 2 entr es par connecteur Equip de 2 embases de a connexion M12 pour 4 entr es H 2 entr es par connecteur om Adressage des entr es om Adressage des entr es x IN1 1 IN1 3 x gt IN1 1 IN1 3 IN2 1 IN2 3 X 1 IN1 2 IN1 4 X 1 IN1 2 IN1 4 IN2 2 IN2 4 voir chapitre 4 5 voir chapitre 4 5 RACCORDEMENT SUR CONNECTEUR M12 Deux mod les de connecteurs M12 sont propos s Connecteur droit duo A pour raccordement de 2 cables individuels un par capteur Connecteur droit mono B pour raccordement d un capteur ou cablage regroup Connecteur a approvisionner Capteur Capteur Capteur Capteur Capteur A Connecteur duo droit M12 a 5 broches males o passage de chaque cable 03 5 mm code 881 00 253 _ B Connecteur mono droit M12 4 A 881 00 253 8768100990 pour 1 entr e de c ble 4 6 mm 5 broches m les code 881 00 330 7 Z71111 7 Sch ma de raccordement des entr es Rep rage vu cot vissage du connecteur m le e capteurs 2 fils e capteurs 3 fils exemp
25. K 4 6 mm p 60 Al 3 5 mm p 63 _ ASTD 20 JOUCOMATIC K ILOTS DE DISTRIBUTEURS PNEUMATIQUES OMS G1 8 G1 4 ou coupleurs commande par Bus de terrain avec protocole AS Interface BUSLINK G n ration C Manuel d installation MS P586 5 FR R2a aog JOUCOMATIC BUSLINK AS Interface INSTALLATION SOMMAIRE Page 1 Le Systeme BUSLINK G n ration C avec protocole AS Interface 3 2 Composants du syst me 5 2 1 Description fonctionnelle 5 2 2 Implantation des composants 5 2 3 Encombrements Fixation 6 7 8 9 2 4 R f rence d un lot BUSLINK G n ration C avec AS Interface 2 5 Commande manuelle auxiliaire 2 6 Distributeurs s ries 569 570 571 3 Montage du BUSLINK G n ration C 10 3 1 Fixation 10 3 2 Raccordement pneumatique 10 4 Raccordement lectrique 12 4 1 G n ralit s 12 4 2 Alimentation en tension 12 4 3 Calcul de la puissance absorb e 12 4 4 Raccordement des entr es 13 4 5 Adressage des entr es sorties 14 4 6 Signaux de commande 16 5 R seau AS Interface 18 5 1 Raccordement du bus AS Interface cable jaune 18 5 2 Instructions de programmation 18 5 3 Raccordement de la tension d alimentation c ble noir 19 5 4 Mise en service du r seau AS Interface 19 5 5 Diagnostic 19 5 6 Fusibles 19 5 7 Accessoires pour AS Interface 20 5 8 Encombrements des accessoires pour AS Interface 20 AV
26. K AS Interface INSTALLATION 5 AS INTERFACE NETWORK 5 1 CONNECTION OF AS Interface BUS The front panel of the pneumatic spool valve island for AS Interface is equipped with vampire type panel connectors for instant connection The yellow flat profiled AS Interface bus cable is screwless and unstripped It is used to transmit control signals and supply the sensor inputs E Connection of the AS Interface bus E AS Interface connection to island ay Bridge ae cra Interface 2 1 AS PC interface master lt lt ee odddexe i Ee a 24V E Connection to AS Interface master AS Interface re D brown Yellow AS Interface cable x Adapter for AS Interface connector o bl This adapter is supplied with the island ue NOTE When connecting the cable to the island please observe the mounting direction of the cable and adapter mounting direction of adapter secured by differently sized side pieces Master NOTE Carry out all programming instructions prior to connecting the black power supply cable 5 2 PROGRAMMING INSTRUCTIONS See AS Interface manufacturer s manual 5 2 1 ADDRESS SELECTION 1 Unscrew the threaded plug to access the addressing switch 2 fall a 2 Set the switch into position 1 and connect the island to the master or the hand held programmer
27. MMUNICATION CHARACTERISTICS Communication protocol Transmission Bus structure Max number of spool valve islands Number of valves per island Number of inputs outputs Max bus cable length Island addressing participants Compatibility with control system Compatible equipment ELECTRICAL CHARACTERISTICS Supply voltage Max ripple ratio Consumption Coil insulation class Protection Electrical insulation of the inputs Peak voltage suppression Additional 24 V supply connection Bus connection IN OUT Input connection Earth connection Electromagnetic compatibility PNEUMATIC CHARACTERISTICS Fluid Operating pressure Flow rate Qv at 6 bar series 569 series 570 series 571 Allowable temperature ACCESSORIES see following page AS Interface bidirectional mode flat AS Interface cable yellow 2 wires any structure according to AS Interface standards 31 nodes 1 valve island can have 2 nodes 4to 8 0 4 or 8 inputs 100 m 300 m with repeaters AS Interface master no modification of current programmes various options 24 V DC 10 at the island Supply to the valves with an additional flat AS Interface cable black 2 wires 10 79 mA per valve and 9 mA per input IP65 optocouplers integrated in the island for each coil vampire type panel connector for AS Interface cable black cable vampire type panel connector for AS Interface cable yellow cable 5 pin
28. PNEUMATIC SPOOL VALVE ISLANDS OM G1 8 G1 4 or instant fittings designed for connection to a PLC by field bus and AS Interface protocol BUSLINK Generation C Installation manual MS P586 5 GB R2a on JOUCOMATIC BUSLINK AS Interface INSTALLATION CONTENTS Page 1 The BUSLINK system Generation C with AS Interface protocol 3 2 System components 5 2 1 Functional description 5 2 2 Component assembly 5 2 3 Dimensions Mounting 6 7 8 9 2 4 Ordering information for a BUSLINK valve island Generation C with AS Interface 2 5 Manual override 2 6 Spool valves series 569 570 571 3 Assembly of BUSLINK Generation C with AS Interface 10 3 1 Mounting 10 3 2 Pneumatic connection 10 4 Electrical connection 12 4 1 General 12 4 2 Voltage supply 12 4 3 Calculation of power draw 12 4 4 Connection of inputs 13 4 5 Addressing of inputs outputs 14 4 6 Control signals 16 5 AS Interface network 18 5 1 Connection of AS Interface bus yellow cable 18 5 2 Programming instructions 18 5 3 Connection of supply voltage black cable 19 5 4 Startup of AS Interface network 19 5 5 Diagnostics 19 5 6 Fuses 19 5 7 Accessories for AS Interface 20 5 8 Dimensions of the accessories for AS Interface 20 CAUTION To avoid malfunction of the bus system please check on any valve island e for correct addressing parameters e all installat
29. RATURE ADMISSIBLE 5 C 50 C FONCTIONS 3 2 2 x 3 2 5 2 5 3 monostables ou bistables ORGANES DE PILOTAGE lectropneumatique alimentation interne PARTICULARITE En version double pilote les 2 pilotes sont int gr s dans une m me t te magn tique monobloc plac e d un seul c t solution plus compacte voir page 5 CONSTRUCTION DISTRIBUTEUR Corps en alliage d aluminium et couvercle en thermoplastique PA Ar Pi ces internes en acier inoxydable alliage d aluminium et r sine ac tal POM Joints d tanch it en nitrile NBR PILOTE Etanch it par garniture en nitrile NBR Appareillage lectrique conforme la norme NF C79300 Bobinage et circuit magn tique monobloc surmoul s Commande s manuelle s impulsion Distributeur 1 Pression 12 Rappel monostable 2 4 Utilisations 14 Commande 3 5 Echappements Distributeur 570 2 x 3 2 Distributeur CARACTERISTIQUES ELECTRIQUES bistable TENSION D ALIMENTATION 24V CC 10 ondulation maxi 10 PUISSANCE ABSORBEE 1 7 W par bobine CLASSE D ISOLATION F DEGRE DE PROTECTION IP 65 SELECTION DU MATERIEL Organes de p lotage Symboles raccordement CODES Fonctions Commande Rappel orifices DISTRIBUTEURS 14 12 d utilisations 24 V coupleur pour tube Electro Ressort souple G6 mm ext 3 000 053 pneumatique Diff rentiel G1 8 570 00 051 Electro
30. a m me valeur en rechange CH A 0000 A Fusible type 20 x 5mm 250V 2A lot de 10 fusibles de rechange pour sorties code 881 00 346 AST 19 JOUCOMATIC K BUSLINK AS Interface INSTALLATION 5 7 ACCESSOIRES POUR AS Interface Distri buteurs D signation 881 66 905 Plaques d obturation des plans de pose lectrique et pneumatique 881 67 001 881 67 101 Bride de connexion pneumatique des orifices d utilisations 2 et 4 pr vue GF 881 35 525 avec t moins de pression et coupleurs pour tube souple 881 35 532 Connecteur duo droit M12 5 broches m les pour 2 entr es 3 5 mm HI 881 00 253 Connecteur mono 1 c ble 84 6 mm droit M12 5 broches m les pour entr es Aro 881 00 330 Cable noir profil pour alimentation 24V 881 00 302 1 2 Plaques destin es a obturer les plans de pose lectrique et pneumatique d un emplacement d lectrodistributeur laiss libre pour une extension ult rieure 3 Longueur en m tres pr ciser la commande 100 m maxi au del nous consulter 5 8 ENCOMBREMENTS DES ACCESSOIRES POUR AS Interface ENTREES M12 ENTREES M12 connecteur DUO droit 881 00 253 Connecteur mono droit 881 00 330
31. buteur 4 14 V0 6 Distributeur 5 14 V1 0 Distributeur 2 12 V0 3 Distributeur 3 14 V0 4 Distributeur 4 14 V0 6 Distributeur 5 14 V1 0 Entr e 4 IN1 4 Entr e 4 IN1 4 Entr e 5 IN2 1 Distributeur 6 14 V1 2 Distributeur 3 12 V0 5 Distributeur 5 12 V1 1 Entr e 6 IN2 2 Distributeur 7 14 V1 4 Distributeur 4 14 V0 6 Distributeur 6 14 V1 2 Entr e 7 IN2 3 Distributeur 8 14 V1 6 Distributeur 4 12 V0 7 Distributeur 6 12 V1 3 Distributeur X 14 mise sous tension bobine Commande 14 Orifice 4 sous pression Distributeur X 12 mise sous tension bobine Rappel 12 Orifice 2 sous pression Entr e 8 IN2 4 1 Sauf distributeur 3 2 NF monostable s rie 570 cot commande 12 orifice 2 sous pression Rappel par mise hors tension de la bobine 12 voir signaux de commande chapitre 4 6 pages suivantes AST JOUCOMATIC 15 BUSLINK AS Interface INSTALLATION 46 SIGNAUX DE COMMANDE MH DISTRIBUTEUR 5 2 MONOSTABLE rappel pneumatique diff rentiel Type M Orifice 2 P Orifice 4 0 P Pression 24V Signal lectrique cot 12 gyl non n cessaire pas de bobine 12 rappel diff rentiel 24V Signal sur bobine 14 commande gy DISTRIBUTEUR 5 2 BISTABLE Type J Orifice 2 Orifice 4 Q Ces signaux peuvent tre impulsionnels ou maintenus jusqu au changement d tat souhait Signal sur bobine 1
32. ent lectrique des entr es Protection lectrique Raccordement suppl mentaire de l alimentation 24V Raccordement du bus IN OUT Raccordement des entr es Prise de terre Compatibilit lectromagn tique CARACTERISTIQUES PNEUMATIQUES Fluide distribu Pression d utilisation D bit Qv 6 bar s rie 569 s rie 570 s rie 571 Temp rature admissible 24 V 10 sur l ilot alimentation des distributeurs par c ble plat AS Interface suppl mentaire noir 2 fils 10 79 mA par distributeur et 9 mA par entr e F IP65 par optocouplage int gr e pour chaque bobine connecteur int gr prise vampire pour c ble AS Interface c ble noir connecteur int gr prise vampire pour c ble AS Interface c ble jaune par connecteur M12 5 broches femelles par la vis de mise la terre sur l embase pneumatique Ces produits sont conformes la directive europ enne CEM 89 336 CEE lls sont certifi s CE air ou gaz neutre filtr 30 um lubrifi ou non 1 5 8 bar 2 5 8 bar avec distributeurs 3 2 NO et s rie 569 fonctions 5 3 175 min ANR 600 I min ANR 3 2 400 I min 2x3 2 550 l min 1050 l min ANR 5 C 50 C ASTA JOUCOMATIC ll INSTALLATION BUSLINK AS Interface 2 COMPOSANTS DU SYSTEME 2 1 DESCRIPTION FONCTIONNELLE Les ensembles et le syst me de commande API sont li s par 1 c ble bus AS Interface jaune pour piloter les distribu
33. es ASTO 6 JOUCOMATIC INSTALLATION BUSLINK AS Interface 2 4 REFERENCE D UN ILOT BUSLINK GENERATION C AVEC AS Interface Pour votre commande nous pr ciser la r f rence de la partie lectrique 1 ainsi que la r f rence de la partie pneumatique A et les ventuels accessoires El Partie lectrique OPTION BUSLINK AS Interface OPTION sans option options ult rieures Possibilit d quiper l flot de 2 ou 4 connec teurs M12 A pour raccordement de 4 ou 8 Nombre JES entr es capteurs suivant le tableau ci contre 1 noeud 4 sorties 1 noeud 4 sorties 4 entr es 2 noeuds 8 sorties 2 noeuds 8 sorties 8 entr es B Partie pneumatique j GR OPTION Nb places 1 2 3 4 5 Nombre d emplacements 4 distributeurs bistables ou 4 8 distributeurs monostables 1 P partie Pneumatique errr S rie et taille E 4 des distributeurs t 569 M5 ou coupleurs type Fonction des distributeurs 570 G1 8 ou coupleurs 571 G1 4 A Plaques d obturations plans de pose pneu et lec OPTION i 00 sans option Z ae NM 3 2 NF Cde lectropneumatique f pa S TE Rappel ressort diff rentiel 99 options ult rieures K Sh BON 2X C
34. ground sensors with 3 wires Input positive logic x PE Protection earth The status of the connected sensors can be sampled over the inputs The inputs have positive logic they can be operated together with sensors with pnp outputs The inputs are LOW and must be switched to 24 V HIGH in order to be activated Typical input current 9 mA at 24 VDC e Logical status LOW lt 8 V Logical status HIGH gt 14 V Max input voltage for external power supply of inputs 40 V When 2 wires sensors are connected the max residual current must be lt 1 mA In LOW status the max residual current at the input must be lt 1 mA ASUS JOUCOMATIC 13 BUSLINK AS Interface INSTALLATION 4 5 ADDRESSING 4 5 1 ADDRESSING OF VALVES Control signals for the valves see chapter 4 6 Valve are addressed according to the type of valve used monostable or bistable valve E Monostable valves max 8 Horizontal addressing Valve position 1 2 3 4 5 6 7 8 Addressing e 0 0 0e V0 0 V0 2 V0 4 V0 6 V1 0 V1 2 V1 4 V1 6 Pilot signals Return signals Ne ee ist node 2nd node E Bistable valves max 4 zX Addressing priority is from top to bottom and from left to right SS oS on Valve SZ ves SY position SE 1 2 3 4 Addressing e
35. guration for 1 node 4 outputs 4 inputs Maximum configuration for 2 nodes 8 outputs 8 inputs 4 monostable 1 output 1 monostable spool valve or 2 bistable 4 2 outputs 2 monostable spool valves or 1 bistable spool or 2 double 3 2 NC valve 8 monostable or 4 bistable 1 In this configuration the bistable spool valves are or 4 double 3 2 NC always to be placed on the right hand side of the island or 4 monostable 2 bistable 1 Number Max number Max number of nodes of valves of inputs 2 2 COMPONENT ASSEMBLY Description Subbase for pneumatic connection of the Buslink valve island AS Interface bus connection Monostable or bistable 3 2 2x3 2 5 2 5 3 spool valves max 8 Operating ports 2 4 with threaded connection or instant fittings top side ports Pressure supply 1 and exhausts 3 5 with threaded connections Connecting flange for pressure supply for island with 8 valves see page 11 LED visual indicator for pilot valves AS Interface adapter for AS Interface bus cable yellow O OINI BR AS Interface adapter for additional AS Interface power supply cable black oO Island addressing 2 LEDs for AS Interface and supply 8 LEDs for in
36. ion adjustment and maintenance operations must be carried out by qualified personnel A separate Declaration of Incorporation relating to EEC Directive 89 392 EEC Annex II B is available on request Please provide acknowledgement number and serial numbers of products concerned This product complies with the essential requirements of the EMC Directive 89 336 EEC and amendments A separate Declaration of Conformity is available on request NOTICE The information in this manual is subject to change without notice In no event shall ASCO JOUCOMATIC be liable for technical or editorial errors or omissions Neither is any liability assumed for accidental or consequential damages arising out of or in connection with the supply or use of the informaton contained herein THIS MANUAL CONTAINS INFORMATION PROTECTED BY COPYRIGHT NO PART OF THIS DOCUMENT MAY BE PHOTOCOPIED OR REPRODUCED IN ANY FORM OR MANNER WHATSOEVER WITHOUT PRIOR WRITTEN PERMISSION FROM JOUCOMATIC COPYRIGHT 1999 2000 ASCO JOUCOMATIC All rights reserved ASTO 2 JOUCOMATIC K INSTALLATION BUSLINK AS Interface 1 The BUSLINK system generation C with AS Interface protocol Pneumatic islands of 4 to 8 monostable or bistable spool valves M5 G1 8 G1 4 with integrated connections for data exchange with a contro
37. l system PLC by means of a field bus and standardized AS Interface protocol 1 Spool valves 8 monostable or 4 bistable valves at maximum 2 Module for AS Interface connection 3 4 or 8 inputs at option NOTE No additional input or output modules available CONNECTION DIAGRAM AS Interface AS Interface master supply yellow cable f 24V IPS black cable AS Interface bridge to other protocols Profibus DP FIPIO Device NET ADVANTAGES With the many advantages it offers the Buslink system meets modern needs for automated installations e No bulky and difficult wiring e Time and money saved due to direct electric cabling and common air supply e Unit tested and equipped with spool valves at delivery e Easy maintenance Bistable spool valves series 569 570 571 with integrated push pull pilot valves pilots placed on COMBINATIONS one side of the island offering a compact solu Buslink units can be grouped as follows tion 1 JOUCOMATIC K Islands of 4 6 or 8 monostable 3 2 5 2 or 5 3 spool valves or 4 bistable spool valves or 4 double 3 2 NC Differently sized islands for spool valve series 569 570 571 only one valve size per island Upon request each island can be equipped with four 5 pin female panel connectors M12 to connect 4 inputs 1 node configuration or 8 outputs 2 node configuration Monostable and bistable spool valves with integrated push pull pilot valves x all func
38. le magn to r sistif 24V 24V 24V 24V Capteur x Capteur Capteur IN x IN Capteur x 1 x x 1 x41 GND IN x IN x 1 GND Nom Description 24V DC IN Alimentation des entr es IN x 1 Entr e logique positive x 1 GROUND Commun capteurs 3 fils IN x Entr e logique positive x 5 PE mise la terre REMARQUE L tat des capteurs raccord s peut tre interrog travers les entr es Les entr es disposent d une logique positive elles peuvent tre op r es ensemble avec des capteurs sorties pnp les entr es sont LOW et doivent tre commut es 24 V HIGH pour tre activ es courant d entr e typique 9 mA 24 VCC e Etat logique LOW lt 8 V e Etat logique HIGH gt 14 V Tension d entr e maxi en cas d alimentation externe des entr es 40 V Lors du raccordement de capteurs 2 fils le courant r siduel doit tre lt 1 mA En tat LOW le courant r siduel aliment l entr e doit tre lt 1 mA ASTO 13 JOUCOMATIC K BUSLINK AS Interface INSTALLATION 4 5 ADRESSAGES 4 5 1 ADRESSAGE DES DISTRIBUTEURS Signaux de commande des distributeurs voir chapitre 4 6 Le mode d adressage des distributeurs est diff rent suivant le type de produits monostable ou bistable E Distributeurs monostables maxi 8 progression de l adressage horizontale Position des distributeurs 1 j 2 3 4 5 6 7 8
39. ment Orifices d utilisations des pilotes 3 5 82 84 2 4 569 G 1 8 M5 M 5 3k 570 3 2 2x3 2 G 1 4 M5 a 570 5 2 5 3 G 1 4 M5 G 1 8 3k 571 G 3 8 M5 G 1 4 ou par bride coupleurs rapides pour tubes souples 4 mm ext rieur 569 e 6 mm ext rieur 570 Version taraud e Version bride coupleurs i ASTO 10 JOUCOMATIC K INSTALLATION BUSLINK AS Interface 3 2 2 RACCORDEMENT DE L ALIMENTATION DE PRESSION E Alimentation par 1 pression P1 llot de 4 6 distributeurs raccordement de l alimentation cot droit S rie Orifices distributeurs 1 3 5 569 G1 8 570 G1 4 571 G3 8 Recommandation de montage Cinq distributeurs peuvent fonctionner simultan ment au maximum sans perturbation pneumatique llot de 8 distributeurs Au del de 6 distributeurs il faut alimenter l ensemble des 2 cot s cet effet les lots de 8 distributeurs sont toujours fournis avec une bride de connexion E Alimentation par 2 pressions diff rentes P1 P2 Possibilit d alimenter 1 4 distributeurs une pression P2 nous consulter E Alimentation externe des pilotes nous consulter ASUS 11 JOUCOMATIC BUSLINK AS Interface INSTALLATION 4 RACCORDEMENT ELECTRIQUE 4 1 GENERALITES Les lots sont quip s de 2 connecteurs AS Interface prises vampires pour raccordement du r seau bus et l alimentation
40. monostable valves or 4 bistable valves and 8 inputs Island reference A3 Island reference A4 Valve addressing Input addressing 4 monostable Node number Data bit 8 monostable 4 bistable valves valves valves and 2 bistable valves Valve 1 14 Valve 1 14 Valve 1 14 Input 1 Input 1 V0 0 v0 0 v0 0 IN1 1 IN1 1 Valve 2 14 Valve 1 12 Valve 2 14 Input 2 Input 2 v0 2 V0 1 v0 2 IN1 2 IN1 2 Valve 3 14 Valve 2 14 Valve 3 14 Input 3 Input 3 VO 4 V0 2 V0 4 IN1 3 IN1 3 Valve 4 14 Valve 2 12 Valve 4 14 Input 4 Input 4 V0 6 V0 3 V0 6 IN1 4 IN1 4 Valve 5 14 Valve 3 14 Valve 5 14 Input 5 V1 0 V0 4 V1 0 IN2 1 Valve 6 14 Valve 3 12 Valve 5 12 Input 6 V1 2 V0 5 V1 4 IN2 2 Valve 7 14 Valve 4 14 Valve 6 14 Input 7 V1 4 V0 6 V1 2 IN2 3 Valve 8 14 Valve 4 12 Valve 6 12 Input 8 V1 6 V0 7 V1 3 IN2 4 4 inputs 8 inputs Valve X 14 voltage supply to pilot coil 14 port 4 under pressure Valve X 12 voltage supply to return coil 12 port 2 under pressure 1 Except for monostable 3 2 valves series 570 where the pilot is 12 port 2 under pressure Return by cutting supply voltage to coil 12 for pilot signals see chapter 4 6 and following pages ASUS JOUCOMATIC amp 15 BUSLINK AS Interface INSTALLATION 4 6 CONTROL SIGNALS E MONOSTABLE 5 2 SPOOL VALVES differential pneumatic return Type M Port 2 Port 4 P Pressure 24V Signal to coil 12
41. n lot ne re oit qu une m me taille de distributeur e Sur demande chaque lot peut tre quip de 4 embases de connexion M12 5 broches femelles pour raccordement de 4 entr es configuration 1 noeud ou 8 entr es configuration 2 noeuds e Distributeurs monostables et bistables double pilote int gr toutes fonctions adaptables sur un m me lot e Toute configuration r alisable la demande ASTO JOUCOMATIC K x Distributeurs bistables s ries 569 570 571 double pilote int gr pilotes plac s du m me cot pour une solution plus compacte Hi CSI BUSLINK AS Interface AS Interface Ensemble de distribution pneumatique pr vu pour communication d informations par bus de terrain via le protocole normalis AS Interface La liaison par bus de terrain entre un syst me de commande API et un ensemble de modules d lectrodistributeurs pneumatiques permet de transmettre par un c ble standard AS Interface tous les signaux e de commande aux distributeurs e d information en provenance des entr es des capteurs AVANTAGES Le syst me Buslink r pond aux besoins modernes d installations automatis es e Suppression des faisceaux de fils encombrants e Economie de temps et de co t par c blage lectrique directe et alimentation pneumatique commune INSTALLATION e Visualisation et d connexion rapide pour une maintenance ais e
42. n adaptateur prises vampires pour raccordement instantan sans vis ni d nudage du cable plat profil bus AS Interface jaune Ce dernier permet le transfert des donn es et l alimentation des entr es capteurs E Raccordement du bus AS Interface E Raccordement AS Interface sur l lot A NS Interface Maitre AS Interface 24V E Raccordement sur Maitre AS Interface AS Interface Marron C ble AS Interface jaune x Adaptateur pour connecteur AS Interface Cet adaptateur est fourni avec I ilot NOTA Lors de la connexion sur l ilot respecter le sens de montage du c ble et de l adaptateur pour ce dernier d trompage par largeurs diff rentes des pattes lat rales INN Bleu Maitre NOTA R aliser les instructions de programmation avant de raccorder le cable noir d alimentation 5 2 INSTRUCTIONS DE PROGRAMMATION Se r f rer au manuel du constructeur AS Interface 5 2 1 REGLAGE DE L ADRESSE 1 D visser le bouchon filet pour acc der l interrupteur de d couplage 2 Mettre l interrupteur sur num ro 1 et connecter Bd K lot au ma tre ou la pocket de programmation TO Position Num ro 3 Affecter l adresse pour le 1 noeud ou par la ET du switch du noeud pocket incr mente
43. ommendation for pressure supply connection see following page E Connections Series Pressure supply Exhausts Pilot valve exhausts Operating ports 82 84 3 5 2 4 569 G 1 8 M5 M 5 3k 570 3 2 2x3 2 G 1 4 M5 E fittings 570 5 2 5 3 G 1 4 M5 G 1 8 3 571 G 3 8 M5 G 1 4 3 or with connecting flange and instant fittings for flexible hose OD 4 mm 569 OD 6 mm 570 Version with threaded connection Version with instant fitting ASTO 10 JOUCOMATIC INSTALLATION BUSLINK AS Interface 3 2 2 CONNECTION OF PNEUMATIC SUPPLY m SUPPLY WITH 1 PRESSURE P1 Island with 4 to 6 spool valves pressure supply on right side Valve series 569 570 571 A maximum of five spool valves can be operated at the same time without pneumatic malfunction Island with 8 spool valves The pressure on an island with more than 6 spool valves must be supplied from both sides For this purpose all islands for 8 to 16 spool valves are equipped with a connecting flange a J P1 3 J E Supply with 2 different pressures P1 P2 Possibility of supplying 1 to 4 spool valves with pressure P2 consult us E External pressure supply of pilot valves consult us ASCO 11 JOUCOMATIC BUSLINK AS Interface 4 ELECTRICAL CONNECTION 4 1 GENERAL INSTALLATION Theislands are equipped with 2 vampire type AS Interface connectors
44. page 20 ASTOA JOUCOMATIC K BUSLINK AS Interface INSTALLATION 2 5 COMMANDE MANUELLE AUXILIAIRE Les distributeurs s ries 569 570 571 sont quip s de commande s A manuelle s auxiliaire s impulsion A distributeur bistable Distributeur monostable Distributeur bistable Actions sur Type de distributeur la les commande s Fonction du distributeur manuelle s Le distributeur est actionn en position travail tant que la commande manuelle est maintenue enfonc e 3 2 5 2 monostables Passage en position rappel lors du relachement de la commande manuelle Le distributeur est actionn en position travail identique commande 14 actionn e Maintien en position travail 5 2 bistable Retour la position neutre centrale ou 5 3 position neutre Le distributeur est actionn en position rappel x identique fonction rappel 12 Maintien en position rappel Retour la position neutre centrale Ces changements d tat ne sont r alis s que lorsque le distributeur est sous pression Pression d alimentation sur orifice 1 1 5 bar mini ASTOS 8 JOUCOMATIC INSTALLATION BUSLINK AS Interface 2 6 DISTRIBUTEURS SERIES 569 M5 570 G1 8 571 G1 4 SPECIFICATIONS FLUIDE DISTRIBUE Air ou gaz neutre filtr 30um lubrifi ou non PRESSION D UTILISATION 1 5 8 bar 2 5 8 bar s rie 569 fonctions 5 3 TEMPE
45. puts i N Input connection with female panel connectors M12 upon request Common exhaust of pilots 82 84 M5 Co ASUS JOUCOMATIC K BUSLINK AS Interface INSTALLATION 2 3 DIMENSIONS MOUNTING PALLIAT TT The island is provided with four mounting holes in the spool valve subbase and two mounting holes on the left side for input output modules The centre distance L2 is dependent on the number and size of the spool valves Total length of spool valve island L2 77 Make sure to provide for enough room on the right side for pressure supply and optional exhaust silencers 28 5 4 F 5 66 5 ot L2 5 5 Valve n2 number of valves series 4 6 8 569 M5 91 5 123 5 155 5 570 G1 8 105 143 181 571 G1 4 126 5 172 5 218 5 mm 1 BUSLINK AS Interface without input height required for pneumatic cabling with rilsan hoses the AS Interface cables are connected horizontally 2 BUSLINK AS Interface with inputs height required for electric connection with M12 connectors and cables WEIGHTS F DL Weight of one bus module Weight of a Buslink island without b dule k eight of a Buslink island without bus module kg without input 0 550 kg Valve n2 number of valves with inputs 0 600 kg series 569 570 3 2 570 5 2 5 3 571 Total weight of
46. r ou d cr menter et faire write M72 a adressage 4 Mettre l interrupteur sur num ro 3 PRE eo 5 Affecter l adresse pour le 2 me noeud ou par la 1219 O has adressage pocket incr menter ou d cr menter et faire write noeud 2 6 Mettre l interrupteur sur num ro 2 Mode 7 Les 2 adresses sont ainsi m moris es dans l lot RUN Remonter le bouchon filet 5 2 2 REGLAGE DE LA VITESSE DE TRANSMISSION Elle est fig e et donn e par le maitre AS Interface 5 2 3 CONFIGURATION DE LA CARTE CONTROLEUR AVEC LES LOTS Dans le cas o la configuration du r seau AS Interface se fait avec coupleur AS Interface int gr l automate voici les codes d identification pour un lot JOUCOMATIC AS Interface Code Entr es sorties Code identificateur d un lot JOUCOMATIC 7 F ID code ASTO 18 JOUCOMATIC INSTALLATION BUSLINK AS Interface 5 3 RACCORDEMENT DE LA TENSION D ALIMENTATION Cette connexion est r aliser apr s avoir effectu toutes les instructions de programmation voir chapitres pr c dents Le raccordement de la tension de service s effectue sur la face avant de l lot l aide du c ble profil AS Interface noir et du connecteur prises vampires Connexion instantan e sur l lot sans vis ni d nudage du cable par clipsage de l adaptateur voir ci dessous E Raccordement sur boitier d alimentation E Raccordement de l alimentation sur l lot Marron
47. r of tweezers 4 Only fuses of the same type and value may be used for replacement A Fuse type 20 mm x 5 mm 250V 2A AST 19 JOUCOMATIC K BUSLINK AS Interface INSTALLATION 5 7 ACCESSORIES FOR AS Interface Valve series Description 881 66 905 Electrical and pneumatic blanking plates 881 67 001 881 67 101 Connecting flange for operating ports 2 and 4 with GF 881 35 525 pressure indicators and instant fittings for flexible hose e 881 35 532 Straight 5 pin male duo connector M12 for 2 inputs outputs 2 cables 3 5 mm HI 881 00 253 Straight 5 pin male mono connector M12 1 cable 4 6 mm for 1 input HI 881 00 330 Black profiled cable for 24V power supply 881 00 302 1 2 These plates can be adapted to islands to block the electrical and pneumatic mounting surfaces of an unused valve place removable for further extension 3 Length to be specified in metres max 100 m please consult us for longer cables 5 8 DIMENSIONS OF THE ACCESSORIES FOR THE AS Interface INPUTS OM12 INPUTS OM12 Straight duo connector 881 00 253 Straight mono connector 881 00 330 PG11 _ PG7 pa EE Le Rt I fh of ato To us S yee Be E Zye ARE ZRSS LOC
48. t chappements 3 5 Utilisations 2 4 Raccordement du bus c ble jaune Alimentation des distributeurs 24 V CC c ble noir OOO Entr es d tecteurs sur demande 3 2 RACCORDEMENT PNEUMATIQUE 3 2 1 GENERALITES E Sur l embase L embase comporte les canaux pour collecter les signaux pneumatiques communs pression d alimentation 1 Echappements 3 et 5 et chappement des lectrovannes pilotes Les orifices de raccordement sont dispos s sur le cot droit de l embase ou pour certaines versions d ilots les orifices de raccordement se trouvent aussi a gauche des distributeurs voir ci contre Sur les distributeurs Deux possibilit s de raccordement des orifices d utilisations 2 4 sur la face sup rieure raccords taraud s directement sur le corps du distributeur raccords instantan s par coupleurs tubes souples sur distributeurs s ries 569 et 570 m Proc dure de raccordement Enlever tous les bouchons de protection en plastique Pour les M5 ou raccords orientables type banjo placer le joint g n ralement fourni avec le raccord Visser correctement les raccords Visser les silencieux d chappement Raccorder les canalisations pneumatiques Lier les tubes afin d obtenir un c blage propre et accessible E Recommandation de raccordement de l alimentation de pression voir page suivante E Raccordements Orifice d alimentation Orifices d chappement Orifices d chappe
49. teurs et relever les tats des capteurs si l lot comprend des entr es Un 2 adaptateur de connexion est utilis pour l alimentation en puissance des distributeurs c ble noir L alimentation en pression et chappement sont raccord s sur les embases pneumatiques par canalisations communes Les distributeurs tablissent l alimentation en pression et l chappement des actionneurs pneumatiques Le raccordement pneumatique des actionneurs s effectue sur la face sup rieure des distributeurs Sur demande l lot peut tre quip d entr es Les capteurs lectriques sont ainsi raccordables au moyen de connecteurs enfichables M12 CAPACITE MAXIMALE DE L ILOT Suivant la configuration choisie les lots peuvent recevoir au maximum 8 entr es et 8 sorties 1 sortie 1 pilote de distributeur La capacit maximale de l lot d pend du nombre de noeuds voir tableau ci dessous Exemple de configurations maximales NOTA Pour 1 noeud la configuration maximale de l ilot est de 4 sorties 4 entr es 4 monostables Pour 2 noeuds la configuration maximale de ou 2 bistables l ilot est de 8 sorties 8 entr es ou 2 doubles 3 2 NF 1 sortie 1 distributeur monostable 8 monostables 2 sorties 2 distributeurs monostables ou 1 bistable ou 4 bistables 7 aes ou 4 doubles 3 2 NF 1 Dans cette configuration les distributeurs bistables sont ou 4 monostables toujours placer a droite sur I ilot 2 bistables 1 Nombre de
50. tions available on one island Any configuration possible upon request ASUS BUSLINK AS Interface INSTALLATION AS INTERFACE AS Interface Pneumatic spool valve island for data exchange via field bus and standardized AS Interface protocol The connection between a control system PLC and several spool valve islands by means of a field bus allows the transmission of data with a standard AS Interface cable e control signals to the spool valves e information signals from the sensor inputs ADVANTAGES With the many advantages it offers the Buslink system meets modern needs for automated installations e No bulky and difficult wiring e Time and money saved due to direct electric cabling and common air supply e Visual display and quick disconnection for easy maintenance e Unit tested and equipped with spool valves at delivery COMBINATIONS Buslink units can be grouped as follows instant fittings 570 G1 8 or instant fittings 571 G1 4 OPTIONS e Island with air supplied at two different pressure rates e Island with external air supply for pilot pressure AS Interface master e Modules for 3 2 2x3 2 5 2 or 5 3 spool valves series 569 M5 or J AS Interface yellow cable supply black cable 24V AS Interface bridge to other protocols Profibus DP FIPIO Device NET etc CO
51. to connectthe bus network and power supply B Upon request the subbases can also be provided with two or four 5 pin female panel connectors M12 forthe inputs A Cables and M12 connectors must be supplied separately Integrated protection circuit for each coil 4 2 VOLTAGE SUPPLY The yellow cable is used to supply the AS Interface The black cable is used to supply the valves and inputs Supply voltage 24 VDC 10 Max ripple ratio 10 Consumption 1 7 per coil 0 2 W per LED max 5 W bus electronics Inputs total value lt 0 5 A Calculation of power draw see below Grounding Grounding for personal protection is effected directly on the island with the ground screw Check the supply voltage during operation and make sure the admissible tolerance 10 is observed 4 3 CALCULATION OF POWER DRAW The island s power draw depends on its configuration Calculating this power draw will allow the user to provide for optimal 24 V power supply Consumption of the different elements Consumption of bus electronics 40 mA Consumption of one input 9mA Consumption of one valve LED 79 mA ASTO JOUCOMATIC K INSTALLATION 4 4 CONNECTION OF INPUTS inputs upon request Connection with detachable M12 connectors with protection to IP65 Possibility of connecting sensors with 2 or 3 wires Island provided with two M12 panel connectors for 4
52. ve bistable spool valve bistable spool valve Valve type Procedure Valve function The valve is activated as long as the manual override is pressed in x 3 2 5 2 monostable Reset when the manual override is released The valve is activated identical to pilot 14 Permanently activated position is maintained 5 2 bistable Reset to central neutral position or 5 3 with neutral position Reset identical to return 12 Reset position is maintained Reset to central neutral position These changes can only be made if the valve is under pressure Supply pressure at port 1 min 1 5 bar ASTO 8 JOUCOMATIC K INSTALLATION BUSLINK AS Interface 2 6 SPOOL VALVE SERIES 569 M5 570 G1 8 571 G1 4 SPECIFICATIONS FLUID air or neutral gas filtered 30um lubricated or not OPERATING PRESSURE 1 5 to 8 bar 2 5 to 8 bar series 569 functions 5 3 ALLOWABLE TEMPERATURE 5 C to 50 C FUNCTION 3 2 2x3 2 5 2 5 3 monostable or bistable OPERATORS solenoid air operated with internal supply SPECIAL FEATURE in the push pull version both pilots are integrated in the operator placed on one side compact solution see P586 2 CONSTRUCTION Monostable Pressure 12 Return SPOOL VALVE spool valve 4 Operating ports 14 Pilot Body in light alloy cover in thermoplastic PA Ar 5 Exhausts Internal parts in stainless steel light

Download Pdf Manuals