Home
Micro Power Server MPS100 Merlin Gerin
Contents
1. Do Introduction et description Introduction and description MAM Montage sur panneau et dimensions M Espace libre autour du produit 50mm Panel mount and dimensions E Clearance around product 50mm Notice d installation Installation manual E90883 Installation Installation Montage plat Flat surface mount Montage sur rail DIN DIN rail mount Notice d installation Installation manual E90885 Installation Installation MAM Raccordement Connection Raccordement ModBUS ma tre E Les c bles et connecteurs ModBUS utilisent le code couleur ci dessous E Bornier vis E Le port ModBUS RS485 est utilis pour raccorder les esclaves ModBUS E MPS100 est ma tre ModBus CCS303 Master ModBUS wiring bd Le E ModBUS cables and connectors all use the CCP303 following colour codes below cable 50961 E Screw type terminal block CJB306 M RS485 ModBUS port is used for connecting uneon binek gona ModBUS daisy chained devices E MPS100 is ModBus master CCP303 cable 50961 Couleur colour Ma tre Master Esclave Slave Jaune yellow Rx Tx Marron brown I Rx Tx Bleu blue EN Tx Rx Blanc white Tx Rx i Noir black EE ov OV Rouge red EM 24V 24V E90886 Notice d installation Installation manual Raccordement port s rie RS232 pour connection modem E Connec
2. MAM Notice d installation Installation manual http 194 2 245 4 mkt microser nsf user name MPS password MPS100 EN LL Do Micro Power Server MPS100 Merlin Gerin Schneider TP Electric MM DD A Danger et avertissement Danger and warning Le montage de ces mat riels ne peut tre effectu que par des professionnels Le non respect des indications de la pr sente notice ne saurait engager la responsabilit du constructeur RISQUE D ELECTROCUTION DE BRULURES OU D EXPLOSION E l installation et l entretien de cet appareil ne doivent tre effectu s que par du personnel qualifi E replacer tous les dispositifs les portes et les couvercles avant de mettre cet appareil sous tension E utilisez toujours la tension assign e appropri e pour alimenter cet appareil Si ces pr cautions n taient pas respect es cela pourrait entra ner des blessures graves This equipment must be mounted only by professionals The manufacturer shall not be held responsible for failure to comply with the instructions in this manual RISK OF ELECTROCUTION BURNS OR EXPLOSION E the device must be installed and serviced only by qualified personnel E put all mechanisms door and covers back in place before energising the device E always supply the device with the correct rated voltage Failure to take these precautions could cause serious injuries MAM Contenu de l
3. emballage NOUBODEN Module avec ses connecteurs embroch s Kit de montage Adaptateur rail DIN Accessoires fixation Manuel d installation Carton d emballage C ble Null Modem din 9 longueur 3 m tres C ble Ethernet droit longueur 3 m tres C ble Ethernet crois longueur 5 m tres Package contents OO O R LJ N Unit with all connectors plugged in Mounting kit DIN rail adapters Mounting accessoires Installation manual Packing box Null modem cable din 9 length 3 m 10 feet Standard Ethernet cable length 3 m 10 feet 7 Crossover Ethernet cable length 5 m 17 feet Notice d installation Installation manual E90881 Introduction et description Introduction and description MM DD Rep rage de l appareil face arri re Port RS485 ModBUS Port s rie RS232 pour connection modem Prise LAN LED La LED activity s allume lorsque le processeur est en fonction La LED S allume lorsque le port LAN communique 5 Connecteur Entr e Sortie 6 Connecteur alimentation 24VDC O DRrROSN Rear panel identification RS485 ModBUS port RS232 serial port for modem connection LAN port LED Activity LED lights when the processor is running ax LED lights when LAN port is communicating Input Output connector 24VDC power supply connector E UARA N A Notice d installation Installation manual E90882 EN LL
4. rce wiring E Screw type terminal block M Cross section 0 6mn min to 1 5mm max Note 1 The 24V available on the ModBUS terminal block can feed up to 16 circuit breaker communication modules BCM or 8 BCM modules 8 craddle communication modules CCM Note 2 If an existing 24VDC power supply is already connected to the ModBUS junction block CJB306 it is necessary to disconnect and reconnect the power supply to the MPS100 Notice d installation Installation manual Ol CESR Caract ristiques techniques Technical data Caract ristiques techniques E Temp rature de fonctionnement 0 C 50 C E Temp rature de stockage 25 C 70 C E Humidit relative 5 90 40 C E Protection IP30 IEC60529 sauf connecteurs IP20 E Perturbations lectromagn tiques Conformit la directive CEM89 336 CEE M Tenue aux vibations suivant CEI 60068 2 6 de 2 13 2Hz 1mm et de 13 2 100Hz 0 7g E Alimentation 24VDC 15 E Limite de tension ondulation comprise 10 E Consommation 250mA Dimensions et poids E Longueur 220mm E Largeur 125mm E Hauteur 40mm E Poids 850gr Notice d installation Installation manual Technical data E Operating temperature 0 C to 50 C E Storage temperature 25 C to 70 C E Relative humidity 5 90 to 40 C E Protection IP30 IEC60529 except IP20 connectors E Electromagnetic disturbance Correspondance to the directive CEM89 336 CEE E Resis
5. tance to vibrations CEI 60068 2 6 de 2 to 13 2Hz 1mm and ro 13 2 to 100Hz 0 79 E Power supply 24VDC 15 M Voltage limit incluing undulation 10 E Consumption 250mA Dimensions and weight E Length 220mm E Width 125mm E Height 40mm E Weight 850g Schneider Electric Industries SAS 89 boulevard Franklin Roosvelt F 92500 Rueil Malmaison France Tel 33 0 1 41 29 85 00 http www schneider electric com GHE11042 AA 00 Ce produit doit tre install raccord et utilis en respectant les normes et ou les r glements d installation en vigueur En raison de l volution des normes et du mat riel les caract ristiques indiqu es par les textes et les images de ce document ne nous engagent qu apr s confirmation par nos services This product must be installed connected and used in compliance with prevailing standards and or installation regulations As standards specifications and designs change from time to tme please ask for confirmation of the information given in this publication LA Ce document a t imprim avec du papier cologique 11 2002 This document has been printed on ecological paper 2001 Schneider Electric All rights reserved
6. teur SUBD9 Wiring of RS232 serial for modem connection E SUBD9 connector Notice d installation Installation manual E90887 Raccordement Connection C ble modem livr avec modem Modem cable is supplied with modem N Line MAM Raccordement Connection Raccordement LAN E Connecteur RJ45 E 100 m tres maximum LAN wiring M RJ45 connector M 100 meter 300 feet maximum length Standard ethernet cable base T E90888 Raccordement E S E Bornier vis d brochable E Section de c blage 0 6mm min 1 5mm max E Couple de serrage 0 4N m E Entr es contacts sec E Sorties relais max 1A Vmax 48V AC DC I O wiring M Screw type terminal block E Cross section 0 6mm min to 1 5mm max M 7ightening tosque 0 4N m M nputs dry contact M Relays outputs Imax 1A Vmax 48V AC DC E90889 Notice d installation Installation manual MM DD D Raccordement Connection Raccordement alimentation M Bornier vis d brochable E Section de c blage 0 6mm min 1 5mm max Nota 1 Le 24V disponible sur le bornier ModBUS permet d alimenter au maximum 16 modules de communication pour disjoncteur BCM ou 8 modules BCM 8 modules chassis CCM Nota 2 Si une alimentation 24VDC est d j connect e au bloc de jonction ModBUS CJB306 il est indispensable de d connecter et de reconnecter l alimentation au MPS100 E90890 Power sou
Download Pdf Manuals
Related Search
Related Contents
ノーパンク自転車 THR5526(取扱説明書)1 Programmable LCR-Bridge HM8118 FMV- 7130MG4 612MG4 500309 - 01 - Manual Panel Solar Termosifon.indd Parents User Guide to SLG - Watford Grammar School for Girls Panasonic electronic modular switching system Telephone User Manual Laurent Wauquiez veut réserver les logements sociaux aux LG E1950T User's Manual ゴセイナイ ト取扱説明書 Copyright © All rights reserved.