Home
SENTRONIC - ASCO Numatics
Contents
1. Pressure switch adjustment window size P7 Proportional gain 1 11 SENSITIVE DEVICES EN100 015 1 at all times Do not connect or disconnect this device when it is energised WARNING This product contains electronic components sensitive to electrostatic discharge If a person or an object come in contact OBSERVE PRECAUTIONS with the electrical components of the product there will be an ea electrostatic charge which can damage or destroy the product DISCHARGE To reduce the risk of electrostatic discharge please observe the handling precautions and recommendations contained in standard PNEUMATIC CONNECTION The pneumatic ports are as follows 1 supply pressure 2 pressure output 3 exhaust Each screw connection is lined with a fitting synthetic sealing disc PTFE polytetrafluoroethylene sealing tape and hemp should not be used as they may get into the inside of the valve and damage it Use an appropriate silencer at port 3 The exhaust time can be longer according to the type of silencer you use The diameter of the pneumatic lines must be adjusted to the nominal diameter of the valve the diameter of output line 2 must be larger or equal to that of input line 1 The supply pressure must always be less than the MAP value max allowable pressure Sentronic with internal Sentronic with external control of the pressure sensor control of the pressure sensor ASCO 20 JOUCOMATIC f
2. free potential 4 20 mA input option 910 508 e Digital input There is another sentronic type which allows control with 8 bit digital setting with hold function D A option 010 537 or 8 bit digital setting with reset function D A option 010 606 FACTORY ADJUSTMENT SENTRONIC valves have following factory adjustment output pressure zero for input signal O volt The span is 10 volts for the band of pressure regulation A minimum hysteresis Maximum proportional gain Adjustment by the customer is possible for further details see following pages For factory adjustment 0 20mA order an option 010 713 4 20mA order an option 910 507 CUSTOMER ADJUSTMENT PROCEDURE First adjust zero point then the span Subsequently if necessary the proportional gain 1 Set minimum output pressure for minimum set point potentiometer P2 2 Set maximum output pressure for maximum set point potentiometer P1 3 Use potentiometer P7 to reduce the proportional gain if necessary ASCO i JOUCOMATIC f ZERO POINT ADJUSTMENT potentiometer P2 GE Example 1 Forhaving a output pressure to 3 bar at 1 volt set point Apply 1 volt and turn P2 potentiometer in clockwise direction to get 3 bar see adjustment precaution below Example 2 For a 2 volts set point output pressure should be O bar Apply 2 volts setting and turn P2 potentiometer in counterclockwise direction to get O bar Turn potentiometer in clockwise dir
3. PE OMA voir sch ma ci contre 7 Utiliser un cable blind pour une protection contre les parasites et les effets lectro statiques Il faut connecter la masse sur le corps du connecteur ASCO JOUCOMATIC 03 04 CONSIGNE ANALOGIQUE Le servodistributeur commande analogique est r gl en usine et livr pour tre utilis avec une consigne 0 10 Volts On peut galement le piloter avec les consignes suivantes e autres plages de tension toutes tensions comprises entre 5 et 5 volts avec une plage de 50 100 exemple 5 5 2 8 etc impedance 100 KO R glages du z ro et de la pente effectuer suivant proc dure d taill e voir pages suivantes e Consigne en courant Pour un r glage usine avec une consigne courant de 0 20 mA impedance 5000 utiliser l option 010 713 entr e flottante 0 20 mA option 010 611 Pour un r glage usine avec une consigne courant de 4 20 mA impedance 50022 utiliser l option 910 507 entr e flottante 4 20 mA option 910 508 e Consigne digitale Une autre version du servodistributeur permet de le piloter avec une consigne digitale 8 bits Fonction m moire option 010 537 ou une consigne digitale 8 bits Fonction RAZ pression option 010 606 INFORMATIONS SUR LES REGLAGES USINE Les servodistributeurs SENTRONIC sont r gl s en usine pour avoir Le z ro de pression de sortie pour OV de consigne Une pente gale 10 volts pour la Pre
4. VERSION AVEC ALIMENTATION EXTERNE DU CAPTEUR DE PRESSION Masse 0 730 Kg Vue de dessous RE el ke m man 555565 mm re 0 0 XXXI 145 G 1 8 alimentation ext rieure du capteur de pression AAS 7770 KARA KANN N AAA A 49594949494959 EXON PRA eo PE 3 OMA A I 5 Hit tous tarau kif e Fixation arri re 2 trous taraud s O G prof S G 1 8 D Fixation frontale alimentation ext rieure C 2 trous O R du capteur de pres sion Sonn wm AT STO 36 175 43 34 3 G 1 4 10 105 45 205 22 5 48 5 G 12 111 10 136 60 240 30 5 G 1 135 15 178 ASCO JOUCOMATIC amp 09 POSITION DES POTENTIOMETRES Oter le couvercle du boitier en d vissant les 4 vis Attention de ne pas desserrer ou d endommager les connexions internes puis intervenir sur le s potentiom tre s de r glage SENTRONIC G 1 8 G 1 4 G 1 2 G 1 P 2 Q lt O N 8 g V P1 R glage de la pente P2 R glage du z ro P4 P5 Calibrage capteur de pression NE PAS MODIFIER CE REGLAGE P6 R glage du pressostat largeur de fen tre P7 Gain proportionnel 1 11 ATTENTION Ce produit contient des composants lectroniques sensibles aux d charges lectrostatiques Tout contact des connexions par une RESPECTER LES PRECAUTIONS personne ou un objet charg d lectricit statique pourrait entrainer la DE MANIPULATION DES PRODUITS SENSIBLES m
5. inverse horaire 0 5 V 10 V 10 mA 20 mA A di T Pression maxi admise par le capteur D calage du z ro potentiom tre P2 P a ATTENTION Si vous tournez le potentiom tre P2 de r glage du z ro dans le sens horaire vous risquez de d passer la valeur de la PMR et de provoquer ainsi un d crochage du servodistributeur Celui ci tablira la valeur de la pression d alimentation de l orifice 1 sur l orifice 2 de sortie utilisation Afin de ne pas d truire le capteur de pression il est recommand que la pression d alimentation soit toujours inf rieure la PMA d finie ci dessus Pour viter ce d crochage r ajuster la pente potentiom tre P1 afin de ne pas d passer la valeur de la PMH lors de la consigne maxi MODIFICATION DE LA PENTE potentiometre P1 Exemple de r glage sur une vanne version PMR 6 bar Pour une plage de consigne de O 10 volts on veut O 5 bar en pression de sortie Appliquer la consigne de 10 volts et tourner le potentiom tre P1 dans le sens inverse horaire jusqu obtenir une pression de 5 bar en sortie de vanne PMR ___ _ _ 0 5 PMR Tourner le potentiom tre dans le sens horaire Tourner le potentiom tre dans le sens inverse horaire R glage de la pente 20 MA potentiom tre P1 Le r glage maximum possible de la pente est gal 100 Pour obtenir la valeur de pression de sortie gale la PMR pente 100 il est n cessaire d avoir au
6. La consigne rampe est utilis e pour ralentir la mont e en pression et viter les MEIN d passements de consigne a VR1 Temps de rampe montante O 4 sec VR2 Temps de rampe descendante 0 4 sec Pression VR1 VR2 Consigne en tension 0 10 V 200 kQ impedance d entr e Consigne en courant 0 20 mA 500 impedance d entr e a gt La pente et l offset doivent tre ajust s comme montr en page 3 OPTION RETOUR ELECTRIQUE EXTERNE nous consulter Au lieu d un capteur de pression interne un capteur externe de pression de force de vitesse de positions etc est utilis La valeur instantan e du capteur de mesure externe est connect e sur la broche 6 du connecteur Consigne en tension 0 10 V 100 kQ impedance d entr e Courant d entr e 0 20mA 500 Q imp dance d entr e Courant d entr e 4 20 mA 500 Q imp dance d entr e La pente et l offset doivent tre ajust s comme montr en page 5 ASCO 07 JOUCOMATIC ENCOMBREMENTS ET MASSES Masse 0 650 Kg LL SC 2 COCO ER NENNEN SR Va Va Va Va XXAXXXA etat tata 145 A Eel KAAAKAARA ettet TEE SI KANARAN DOOOQOO0OC BORO 2 trous taraud s G prof S 2 trous R nominal mm 1 1 1 5 08 e Fixation arriere e Fixation frontale Vue de dessous e r DOOOO0Q Pm Re 1 2 MA 5 Z Y ol E Z_ ASCO JOUCOMATIC el ENCOMBREMENTS ET MASSES
7. NE SORTIE S0 mA Maxi 5 CONSIGNE 12V EEE ae Sortie VALEUR INSTANTANEE 5 POTENTIOME TRE ou DE PRESSION DE SORTIE RE l Entr e X0 10V option 0 20mA ou 4 20mA SORTIE PRESSOSTAT NPN SI CONSIGNE ATTEINTE l 500mA maxi PNP SI CONSIGNE Z OP TION OU EU moxi ae nwe e NPN SI CONSIGNE NON ATTEINTE 500mA maxi OU a a e at one PNP SI CONSIGNE a Dy NON ATTEINTE 010612 2 500 mA maxi OPTION 30V maxi 010613 Entree signal capteur si la vanne est configur e en retour lectrique externe du capteur de pression ATTENTION 1 La bobine doit tre aliment e en 24V courant continu variation 10 avec un taux d ondulation 10 maxi pas d alimentation par pont de diode une surtension ou un taux d ondulation sup rieur a 1096 peuvent d t riorer l lectronique 2 Le courant maxi sur la borne 7 est 500 mA sortie de l alarme NPN PNP La borne 7 est prot g e contre les courts circuits et les surcharges 3 Si vous connectez un relais charge inductive sur la sortie pressostat il est n cessaire d utiliser une diode de roue libre ou une varistance 4 Ne pas souder les broches non utilis es du connecteur femelle 5 En cas de coupure de l alimentation de pression couper l alimentation 24V SENTRONIC ou mettre la consigne OV afin d viter un chauffement excessif de la bobine 6 Le corps de la vanne doit tre reli a la terre par l interm diaire de la borne de masse
8. S Weight 0 650 Kg View from below ROSS m dette Wette um men me Siete RR m DO T VF FF OOO 3 3 OA DO A 5 B E ANANA QOODOOCO QOODPDOOO 12222 etats SX k ZAN 145 81 26 6 ANA R994 DOODO SSD KO ON lo LA e Front mounting by 2 holes R eo PE 5 1 O e Rear mounting by 2 1 RE tapped holes G C depth S flu ASCO 18 JOUCOMATIC DIMENSIONS AND WEIGHTS VERSION WITH EXTERNAL PRESSURE PORT FOR THE SENSOR Weight 0 730 Kg View from below _ n KOKA 77 s No 6 0 4 145 G 1 8 pressure sensor external input KON DO O CKPOOOC 494949 94949594 DOPO OOO IIS e Rear mounting by 2 tapped holes G depth S e Front mounting by G 1 8 2 holes R Pressure sensor external input D EJFJ JG H 2JJ K Lt JR S Weights Kg 43 4 4 6 10 10 15 6 36 10 20 M6 16 11 34 3 G 1 4 92 12 45 57 5 12 28 M6 22 5 15 485 G1 2 111 20 60 79 15 33 M8 30 5 20 60 G 1 135 ASUS JOUCOMATIC 19 POSITION OF POTENTIOMETERS AND JUMPERS Remove the lid of the body by unscrewing the 4 screws Caution do not loosen or damage the cable connections and adjust the potentiometer SENTRONIC G 1 8 G 1 4 G 1 2 G 1 QE V P1 Span adjustment P2 Offset adjustment P4 P5 Gauging of pressure sensor DO NOT MODIFY THIS ADJUSTMENT P6
9. Servodistributeurs s rie 601 a commande analogique Servo valves series 601 with analogic control SENTRONIC Manuel d installation Installation manual MS P300 11 R1a 883 45 63 ASCA oo JOUCOMATIC 02 SOMMAIRE Raccordement lectrique du connecteur Raccordement pneumatique Consigne analogique Modification d calage du z ro Modification de la pente Gain proportionnel Pressostat option et r glage Option rampe Option retour lectrique externe Encombrements et masses Position des potentiom tres Mise en service en anglais 03 10 04 05 05 06 06 07 07 07 08 09 10 11 Ce produit est conforme aux exigences essentielles de la Directive 89 336 CEE sur la Compatibilit Electromagn tique et amendements Il est certifi CE Une d claration de conformit peut tre fournie sur C C simple demande Conform ment la directive CEE 89 392 CEE Annexe II B une D claration d incorporation peut tre fournie sur demande Veuillez nous indiquer le num ro d accus de r ception AR et les r f rences ou codes des produits concern s ASCO JOUCOMATIC RACCORDEMENT DU CONNECTEUR SUR SENTRONIC A COMMANDE ANALOGIQUE G 1 8 3 mm G 1 4 6 mm G 1 2 12 mm G1 20 mm Connecteur broches Vu c t soudure du connecteur femelle TON CONNECTEURS SUR CARTE ELECTRONIQUE DE LA SENTRONIC 10V ou O 20mA ou 4 20mA MASSE CONSIG
10. can use gain adjustment in a range from 1 to 11with potentiometer P7 Proportional gain is factory adjusted to maximum 11 You can use proportional gain to reduce oscillation and overshoot To increase the gain turn P7 clockwise To becrease the gain turn P7 counterclockwise PRESSURE SWITCH OPTION FOR THE SENTRONIC PORT PRESSURE SWITCH enon IG _ USED T CODE diameter OPTION BETWEEN TRANSISTOR OPTION iun ko ka pin 7 24V and pin 7 aa aa Signal LOW LIS PN Signal 24V DC on pin 7 Ground and pin7 Open collector signal HIGH 010 579 if setting is reached PNP Ignatii Signal 24V DC on pin 7 Open collector a if setting is not reached Ground and pin 7 P PNP Signal HIGH ee ee on one 24V and pin 7 Open collector Signal LOW 010 613 if setting is not reached NPN NOTE The output signal tolerance is adjusted at 5 PMR at factory 100 Too P Setting d reached P Setting not reached p P Setting not 5 reached VW 0 5V 10V 5 Yo 1mA 20mA This tolerance can be varied from 1 4 96 to 6 Yo max with potentiometer P6 The maximum output current of pin 7 is 500 mA at 24 V DC See operating diagram page 13 ASCO 16 JOUCOMATIC PRESSURE SWITCH ADJUSTMENT 1 Connect the Sentronic connector according to page 13 Do not apply pressure to the input port 2 Turn potentiometer P6 clockwise to its maximum value there is no limit stop 3 Connect a LED with resistor 4 7 KQ between pi
11. ction Analogic control Offset adjustment Span adjustment Proportional gain Pressure switch option and adjustment Option set point ramp Option external feedback value input Dimensions and weights Position of potentiometers 13 20 14 19 15 16 16 17 17 17 18 19 20 This product complies with the essential requirements of the EMC Directive 89 336 EEC and amendments Certified CE A separate Declaration of Conformity is available on request A separate Declaration of Incorporation relating to EEC Directive 89 392 EEC Annex II B is available on request Please provide acknowledgement number and serial numbers of products concerned ASCO JOUCOMATIC WIRING CONNECTOR ON SENTRONIC WITH ANALOGIC CONTROL G 1 8 3 mm G 1 4 6 mm G 1 2 J 12 mm G1 20 mm 7 PINS CONNECTOR View on the soldered wires __ PLUGS ON side of female connector H ELECTRONIC CARD __ OUTPUT BO mA Moxi sl SETTING 12V 0 tov tool peire a a FEEDBACK 6 Input 0 10 V option 0 20mA ou 4 20mA i PRESSURE SWITCH OUTPUT NPN IF SETTING OPTION IS REACHED 010539 EO oA mai P Ov A PNP IF SETTING Z NPN IF SETTING E OPTION 30 V maxi IS NOT REACHED j 010613 500 mA maxi NPN PNP IF SETTING 7 OP TION IS NOT REACHED 010612 500mA maxi External feedback value input if the valve is configurated for external sensor WARNING 1 It is necessary to use a p
12. e 21 0 5v 10V 9 1mA 20mA On peut faire varier cette tol rance de 1 4 96 6 au maximum par l interm diaire du poten tiometre P6 Le courant de sortie maximum d livr sur la borne 7 est de 500 mA sous 24 V DC voir sch ma de principe page 03 ASCO 06 JOUCOMATIC REGLAGE DU PRESSOSTAT 1 Raccordez la Sentronic suivant le sch ma en page 03 Ne pas appliquer de pression en entr e de la vanne 2 Initialisation du potentiom tre P6 en le tournant dans le sens horaire pas de but e franche voir dessin p10 3 Raccorder une diode de visualisation mont e en s rie avec une r sistance de 4 7 KQ entre la borne 7 et la borne 2 ou entre les bornes 7 et 1 suivant le type de l option pressostat 4 7 kQ 4 7 kQ Z A 7 9 24V L PNP 0V OV NPN 24V 4 Appliquer une consigne repr sentant la valeur de la moiti de la sensibilit totale requise Sans pression dans la vanne Exemple pour une Sentronic 0 3 bar si vous souhaitez une fen tre de pressostat de 70 mbar 0 07 3 2 2 3 Yo de 10 volts il faut une consigne de 0 23 volt 5 Tourner le potentiom tre P6 dans le sens inverse horaire jusqu ce que la diode de visualisation change d tat OPTION RAMPE 010 610 Elle permet de faire voluer lin airement la pression suivant des pentes montantes ou descendantes Les pentes montantes ou descendantes peuvent tre r gl es s par ment par un potentiom tre VR1 LF
13. ection Latch up zone PMR Max pressure Max pressure of regulation supply PMR MAP Dat bar Turn potentiometer in counterclockwise direction 5 V 10 V 10 mA 20 mA Offset adjustment potentiometer P2 Max pressure accept by the sensor WARNING If you turn potentiometer P2 clockwise the maximum output pressure PMR may be exceeded and the valve overdrives This means that the output pressure cannot be regulated anymore and the full supply pressure is applied Therefore at an increased zero point the span P1 must be reduced to avoid valve overdrive In order to avoid damaging the sensor the supply pressure must always be less than the maximum input pressure MAP defined above SEA ARUTA MENT plen tom Example Valve adjustment with PMR of 6 bar For a setting range of 0 10 volts the desired output pressure range should be 0 5 bar Apply the setting of 10 volts and turn potentiometer P1 counterclockwise to obtain 5 bar output pressure PMR 0 5 PMR Turn potentiometer in clockwise direction Turn potentiometer in counterclockwise direction Span adjustment potentiometer P1 The maximum possible adjustment of the span is 100 To obtain an output pressure value equal to the PMR span 100 there must be a potential difference of at least 10 volts voltage setting or 20 mA current setting You can only reduce the output pressure ASUS JOUCOMATIC f 15 GB PROPORTIONAL GAIN You
14. ise en panne ou la destruction de appareil Tt AUX DECHARGES Pour r duire les risques de d charges lectrostatiques veuillez ELECTROSTATIQUES respecter les recommandations et precautions de manipulation d finies par E S D la norme EN100 015 1 avant toute intervention sur ce produit Ne pas connecter ou d connecter cet appareil lorsqu il est sous tension RACCORDEMENT PNEUMATIQUE Les orifices pneumatiques sont les suivants 1 pression 2 utilisation 3 chappement L tanch it des raccords doit se faire par un joint synth tique L tanch it par ruban PTFE polyt trafluoro thyl ne ne doit pas tre utilis e car des particules pourrait endommager l int rieur de la vanne Utiliser un silencieux appropri pour l orifice 3 Le temps d chappement peut varier suivantle type de silencieux utilis Le diam tre des canalisations peumatiques doit tre ajust en fonction du diam tre nominale de la vanne Le diam tre des canalisations pour l orifice 2 doit tre plus grand ou gal que celui pour l orifice 1 La pression d alimentation doit toujours tre inf rieure la valeur de PMA Sentronic avec alimentation Sentronic avec alimentation interne du capteur de pression externe du capteur de pression ASCO 10 JOUCOMATIC f Servo valves series 601 with analogic control SENTRONIC Installation manual MS P300 11 R1a ASCA JOUCOMATIC SUMMARY Electrical connection Pneumatic conne
15. minimum une diff rence de potentiel ddp de 10 volts consigne tension ou 20 mA consigne courant On ne peut que r duire la pression de sortie ASCO JOUCOMATIC amp 05 GAIN PROPORTIONNEL On peut ajuster le gain dans une plage de r glage de 1 11 avec le potentiom tre P7 Le gain proportionnel est r gler en usine au maximum 11 On peut adapter le gain proportionnel pour r duire l oscillation et les d passements over shoot Pour augmenter le gain il faut tourner P7 dans le sens horaire Pour diminuer le gain il faut tourner P7 dans le sens inverse horaire OPTIONS PRESSOSTAT POUR SENTRONIC DE RACCORDEMENT OPTION RELAIS ACTIV TRANSISTOR LOGIQUE CODE J de passage PRESSOSTAT SI RACCORD ENTRE UTILISE OPTION Reference de masse sur borne 7 24V et borne 7 Collecteur ouvert Signal BAS 010 539 si consigne atteinte NPN A Signal 24V CG sur bome 7 1 masse et la bome 7 Collecteur ouvert Signal HAUT 010 579 G 1 4 6 mm Si consigne atteinte PNP G 12 12 mm Signal 24V CC sur borne 7 Collecteur ouvert c G 1 20 mm si consigne non atteinte la masse et la borne 7 Signal HAUT 010 612 R f rence de masse sur borne 7 24V etbome 7 Collecteur ouvert signal BAS 010 613 si consigne non atteinte La tolerance sur le signal de sortie est r gl e 5 de la PMR en sortie usine NOTA 100 so itd pi Consigne PMR 7 atteinte Consigne y non atteinte Consigne non atteint
16. n 7 and pin 2 or pin 7 and pin 1 according to the pressure switch option PNP OV OV NPN 24V 4 Apply a set point according to the half window size without pressure at the input of the valve Example for a 0 3 bar SENTRONIC you need a 70 mbar window size 0 07 32 2 3 Yo of 10 volts Apply a set point of 0 23 V 5 Turn P6 counter clockwise until the LED status is changed OPTION SET POINT RAMP 010 610 It allows to transform a set point bounce into a set point ramp Rising or falling ramps can be adjusted separately by means of a potentiometer VR1 C The set point ramp is used to retard the valve s reaction and avoid overshoot VR2CH VR1 Ramp time for rising set point O 4 sec VR2 Ramp time for falling set point O 4 sec Pressure Voltage input 0 10V 200 kQ input resistance VR1 VR2 Current input O 20mA 500 Q shunt resistance Set point The span and zero point must be adjusted as shown on page 15 LLL OPTION EXTERNAL FEEDBACK VALUE INPUT consult us Instead of the internal pressure sensor an external sensor for pressure force speed position etc is used The external feedback value is supplied to pin 6 of the connector Voltage input 0 10V 100 kO input resistance Current input 0 20mA 500 shunt resistance Current input 4 20mA 500 O shunt resistance The span and zero point must be adjusted as shown on page 15 ASCO 17 JOUCOMATIC DIMENSIONS AND WEIGHT
17. ower supply with 24V direct current 10 tolerance with a max 10 ripple no supply per diode bridge Over voltage or a ripple rate of over 10 can damage the electronic 2 Max current of pin 7 is 500 mA output NPN PNP Pin 7 has a short circuit and a overload protection 3 If you connect a relay inductive load to pressure switch output you must use a freewheel diode or a varistor 4 Don t solder to unused pins on the female connector 5 In case of an interruption in the pressure supply shut off the power supply 24V or switch the set point to zero to avoid excessive heating of the coil 6 Grounding for personal protection must be done at the PE thread OMA on the body 7 Use a shielded cable for EMC protection Connect the shield to ground and to the connector body ASTO JOUCOMATIC amp 13 ANALOGIC CONTROL The sentronic is factory adjusted for O 10 V input voltage It can also be controlled with following input signals e Other voltage range Every zero voltage in a range going from 5 to 5 volts with a 50 100 span For example 5 45V 2 8 and so on impedance 100 KO Adjustment of offset and span refer to the detailed procedure See following pages e Current input For factory adjustment 0 20 mA input current impedance 500 use option 010 713 free potential 0 20 mA input option 010 611 For factory adjustment 4 20 mA input current impedance 500 Q use option 910 507
18. ssion Maximale de R gulation PMR command e Une hyst r sis minimum Gain proportionnel maximum La modification de ces r glages est cependant accessible l utilisateur pour les be soins d applications sp cifiques voir pages suivantes Pour un r glage usine 0 20 mA commander une option 010 713 4 20 mA commander une option 910 507 PROCEDURE DE REGLAGE R glage du z ro en premier puis r glage de la pente et si n cessaire du gain proportionnel 1 R gler la pression de sortie mini pour la consigne minimum potentiometre P2 2 R gler la pression de sortie maxi pour la consigne maximum potentiom tre P1 3 Si n cessaire possibilit de r duire le gain proportionnel potentiom tre P7 ASCO JOUCOMATIC MODIFICATION DECALAGE DU ZERO potentiom tre P2 F Exemple 1 Pour avoir une pression de sortie de 3 bar 1 volt de consigne Appliquer une consigne de 1 volt et tourner le potentiom tre P2 dans le sens horaire jusqu obtenir 3 bar voir pr caution de r glage ci dessous Exemple 2 Pour une consigne de 2 volts on veut une pression de 0 bar Appliquer la consigne de 2 volts et tourner le potentiom tre P2 dans le sens inverse horaire jusqu obtenir O bar Tourner le potentiom tre dans le sens horaire Zone de d crochage PMR Pression maxi Pression maxi de r gulation d alimentation PMR PMA pat bar Tourner le potentiom tre dans le sens