1. low If the low battery light is lit on the control box make sure your battery is properly charged C The system may be clogged with debris Make sure pipes are not plugged and that the pump openings are clear What size fuse is A 12 amp fuse for the RED Positive battery lead required We recommend a deep cycle marine battery with 100 AH rating SHUR DRI WARRANTY EXCLUSIONS SHUR DRI SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AFTER THE TERMINATION OF THE WARRANTY PERIOD SET FORTH HEREIN Some states do not permit some or all of the above warranty limitations and therefore such limitations may not apply to you No warranties or representations at any time made by any representatives of SHUR DRI shall vary or expand the provision hereof LIABILITY LIMITATION IN NO EVENT SHALL SHUR DRI BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY SHUR DRI PRODUCT OR PARTS THEREOF PERSONAL INJURY AND OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION SHUR DRI DISCLAIMS ALL LIABILITY INCLUDING LIABILITY UNDER THIS WARRANTY FOR IMPROPER INSTALLATION SHUR DRI RECOMMENDS FOLLOW ING THE INSTRUCTIONS IN THE INSTALLATION MANUAL WHEN IN DOUBT CONSULT A PROFESSIONAL Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation o
2. on my control panel what s wrong A Maybe nothing at all A slow flash rate about 1 second or less indicates that the charging system has nearly charged the battery to its optimum charge level The flashing LED s should slow and eventually stop when the battery is completely charged A fast LED flash rate more than 2 per second indicated the 1 A charging fuse has blown the battery leads are reversed or the wall transformer is not supplying proper voltage to the control box Check the battery connections then replace the fuse If the LED s continue to fast flash check the 115V outlet for proper current and replace the plug in wall transformer if necessary A severely dis charged battery may also cause a surge in the system and blow the fuse if connected Q When hooked up the system the yellow charging light came on Why The battery was supposed to be fully charged when got it A A new battery although charged adequately to start most engines will not be charged to its full optimum level The charging system supplied with your pump monitors the charge level and slowly charges the battery to its optimum level Q O K after 2 days the LED s are blinking be tween charged and charging what s wrong now A Probably noting see question 2 above The system normally takes 2 3 days to fully charge a good battery from about 11 9 VDC to 14 4 VDC As the battery approaches full charge the LED s wi
3. or primary sump pump One can PVC cement read directions carefully One check valve SD CV 170 NOT INCLUDED Tools Needed for all pump installations Crescent or socket wrench Philips screwdriver 24 tooth hacksaw knife or round file The nylon belt with buckle two rigid nylon straps and four screws are not needed and can be discarded STEP Remove cover from sump and disconnect the primary sump pump from the discharge pipe 4 Lift primary sump pump out of sump STEP Attach control panel to battery box with four 2 screws supplied Place J2 volt battery not in luded into battery box wank 25581A015 STEP Tighten battery clamps onto battery terminais With bolts and retainer plates supplied attach RED control panel lead to POS ITIVE battery clamp Attach BLACK control panel lead to NEGATIVE battery clamp The RED wire is supplied with an in line fuse to protect the battery pump and wiring should a short over current or ground fault occur If the fuse must be replaced for any reason it must be replaced with one of the exact same rating Failure to do so may result in a fire hazard If the leads are connected to the wrong terminals the REVERSE control panel indicator will light Reverse the leads If battery voltage is less than 11 volts DC the LOW control panel indicator will light Recharge or replace battery BOLT RETAINING t PLATE H r CO NTROL BATTERY L CL
4. AMP E iy PANE MP _ 05 LEAD h BATTERY TERMINAL STEP Thread male PVC adapter into primary 4 pump discharge open ing Cement a 3 4 piece of PVC pipe to adapter Use appropriate diameter piping PRIMARY SUMP PUMP below the top of the er back up 9 sump pump oS STEP Clamp check valve SD CV 170 to top of PVC pipe with water flow arrow point ing away from pump CHECK VALVE STEP Clamp enough BACK UP PUMP ROTATED 30 6 PVC pipe to Fa 4 MINIMUM f check valve SD CV 170 to place the bottom of the back up sump pumpa minimum of 1 above the top of the primary sump pump and the top of the back up sump pump a minimum of 4 DUAL SIZE TEE ADAPTER 1 MINIMUM sump basin STEP Thread dual size tee adapter onto back up 7 sump pump Tighten then rotate the back up sump pump 30 to prevent airlocking BACK UP SUMP PUMP STEP Cement enough PVC pipe to 8 connect tee adapter to dis charge Tether float sensor to discharge pipe with plastic clamps pro vided Tether 1 1 4 Float sensor should not hang lower than suction inlet of the back up sump pump and at least 2 below top of sump DISCHARGE PIPE BACK UP PUMP SUCTION INLET STEP Plug AC charg and float sensor into control panel slots labelled CHARGER PUMP and SENSOR respectively Plug AC charger into an outlet Complete installation should look like drawing to the far rig
5. INSTALLATION MANUAL 12 VOLT EMERGENCY gt SUMP PUMP SYSTEM SD BSP 12 VOLT SYSTEM MODEL SD BSP _ _ Battery not included WARRANTY PRODUCT DEFECTS COVERED 12 MONTHS FROM DATE OF PURCHASE OR 18 MONTHS FROM DATE OF MANUFACTURE RECEIPT AND PRODUCT DATE CODE REQUIRED FOR WARRANTY CLAIM SHUR DRI ASHLAND OHIO 44805 1969 25581A015 1 READ THESE RULES AND INSTRUCTIONS CAREFULLY 2 Before installing or servicing your pump BE CERTAIN pump power source is disconnected 3 Plumbing and electrical wiring must adhere to state and local codes Check appropriate community agen cies or contact local electrical and pump professionals 4 Keep the battery box in a cool dry well ventilated area away from sparks or flames Battery exposure may result in an explosion or fire 5 Beware of battery acid it is very corrosive 6 BATTERY SELECTION Use a new fully charged 12 volt battery with top terminals We recommend a deep cycle marine battery minimum 100 AH Automotive batteries may be used with a slight de crease in performance and life Group 24 batteries will fit into the battery box with maximum battery dimen sions of 12 L x 6 1 2 W x 9 H to the top of terminals 7 BATTERY MAINTENANCE every 3 months on batteries with removable top caps Unplug battery IMPORTANT SAFETY INSTRUCTIONS BEFORE INSTALLATION Failure to follow these instructions may cause serious bodily injury and or property damage
6. Un fusible de 12 A pour le fil ROUGHE de batterie positif Nous recommandons l utilisation d une batterie pour bateau d charge profonde de 100 AH SHUR DRI EXCLUSIONS A LA GARANTIE APR S L EXPIRATION DE LA GARANTIE D CRITE DANS LES PR SENTES SHUR DRI SE DESISTE SP CIFIQUEMENT DE TOUTE GARANTIE IMPLICITE DE COMMER CIALISATION O DE CONVENANCE POUR UN USAGE QUELCONQUE Quelques Etats interdisent certaines ou l ensemble des restrictions ci dessus et il est donc possible que les restrictions ci dessus ne s appliquent pas vous Aucune garantie ou repr sentation faile un moment quelconque par un repr sentant de la soci t SHUR DRI ne saurait s carter ou largir la clause ci dessus RESTRICTION DE RESPONSABILIT LA SOCI T SHUR DRI NE SAURAIT SOUS AUCUNE CIRCONSTANCE ETRE TENUE RESPON SABLE DE DOMMAGES INDIRECTS SECONDAIRES OU SPECIAUX ATTRIBUABLES OU RELIES DE QUELLE QUE FA ON QUE CE SOIT A UNE PIECE OU UN PRODUIT SHUR DRI DE MEME QUE DE TOUTES LES BLESSURES ET OU DOMMAGES MATERIELS ATTRIBUABLES A UNE MAUVAISE INSTALLATION SHUR DRI SE DESISTE DE TOUTE RESPONSABILITE Y COMPRIS LES RESPONSABILITES LIEES A CETTE GARANTIE SI L INSTALLATION N EST PAS ADEQUATE SHUR DRI RECOMMANDE DE SUIVRE LES INSTRUCTIONS APPARAISSANT DANS LE MANUEL D INSTALLATION EN CAS DE DOUTE CONSULTER UN PROFESSIONNEL f Certains Etats ne permettent pas exclusion ou la restriction des dommages indirects ou seco
7. charger Measure the specific gravity of the electrolyte in each cell with a hydrometer If the specific gravity falls below 1 225 in any one cell or varies more than 050 between all the cells replace the battery Check the electrolyte level and fill as required Check battery terminals and clamps for tightness and corrosion service as required Plug battery charger back in 8 Replace the baitery if the back up pump operates for an extended period and severely discharges the battery We recommend battery replacement every 3 years regardless of system use 9 When servicing the pump use care Disconnect power at main electrical service box by turning circuit breaker off or by removing the fuse Disconnect battery charger from wall outlet DO NOT lift pump by the power cord 10 This system is intended for back up use during power outage not as a primary pump Do not run dry 11 SAVE THESE INSTRUCTIONS SYSTEM INSTALLATION Be certain sump basin is clean and all power to pump is shut off If pump fails to operate properly after installa tion refer to troubleshooting checklist on page 4 or con tact Shur Dri All parts with part numbers are quality Shur Dri paris General Materials Needed One 12 volt emergency sump pump system SD BSP Includes 12 volt back up pump float switch control panel 12 volt charger battery box dual size tee adapter terminal clamps wire ties bolts and screws Does not include battery
8. ht 25581A015 COMPLETE BACK UP SUMP PUMP INSTALLATION a OPERATION amp TESTING TESTING After installation unplug the primary sump pump and fill the sump with water This is actually imitating the condition that would happen if the power went off or the primary pump failed for whatever reason The back up sump pump should begin operation as the water level rises just above it s top If not the float sensor may need to be re positioned review float installation instructions Even after the back up has pumped the excess water out and shut off the alarm should continue sounding until the ALARM switch is set to the OFF position The alarm continues to sound until the ALARM switch is set to OFF to alert you that something is wrong with the primary sump pump If the back up pump operates properly plug in the primary sump pump and set the ALARM switch ON and press the RESET button The back up system is now in full readiness if the back up pump does not operate as specified refer to the troubleshooting checklist OPERATION z When the FLOAT SWITCH turns the back up pump ON the alarm buzzer will sound When the FLOAT switch turns the back up OFF the buzzer will continue to sound until the ALARM switch is pushed to the OFF position Push the ALARM switch to the ON position Press the RESET button for normal operation lf the voltage of the battery drops lower than 11 volts DC the LOW battery
9. indicator will come on and the buzzer will sound if the ALARM switch is in the ON position At this time the battery should be checked and serviced or replaced The only real test for a battery is when it is tested with a load meter Take the battery back where it was purchased for the test The CHARGING indicator will come ON when the battery is UNDERCHARGED The CHARGING indicator will turn OFF when the DC voltage is over 13 volts then the CHARGED indicator will come ON At this time the battery is at FULL CHARGED condition and will stop charging The CHARGED indicator will be ON until the DC voltage drops The battery will start charging again and the CHARGING indicator will come ON If either CHARGING indicator and CHARGED indicator are not ON check the charger adapter for proper connection Near the end of the CHARGING cycle the CHARGING and CHARGED indicators may alternately blink IF the lights blink continuously check the battery leads for proper polarity Step 3 and replace the fuse Press PUMP TEST switch for pump function test the pump comes ON and ALARM indicator comes ON and BUZZER sounds Release the PUMP TEST switch the pump turns OFF but the BUZZER continues to sound and ALARM indicator continues to be ON Press the RESET switch the BUZZER and ALARM indicator light will turn OFF oo 25581A015 Frequently Asked Questions on Battery Back up Sump Pump Systems Q The red and yellow LED s flash
10. ison de mat riaux ou de fabrication de SHUR DRI Contacter le commergant SHUR DRI autoris le plus proche pour un service sous garantie SHUR DRI a seul le droit de d terminer s il faut r parer ou remplacer l quipement les pi ces ou les composants d fectueux CETTE GARANTIE NE COUVRE PAS LES DOMMAGES DUS LA FOUDRE OU D AUTRES CONDI TIONS HORS DU CONTR LE DE SHUR DRI POMPES Garantie de 12 mois partir de la date d achat ou 18 mois partir de la date de fabrication Le talon d achat et le code de date de produit sont n cessaires pour les r clamations sous garantie MAIN D OEUVRE ET CO TS SHUR DRI NE sera EN AUCUN CAS responsable du co t de la main d oeuvre sur le terrain ou des autres frais encourus par un client en retirant ou en remettant en place un produit une pi ce ou un composant de produit SHUR DRI pump CETTE GARANTIE NE S APPLIQUE PAS a aux d fauts ou aux d faillances r sultant d une installation d une utilisation ou d un entretien de l appareil non conformes aux instructions imprim es fournies b aux d faillances r sultant d un abus d un accident ou d une n gligence c aux services d entretien normaux et aux pi ces utilis es en relation avec ces services d aux unit s qui ne sont pas install es conform ment aux codes locaux r glements et pratiques commerciales applicables e si l unit est d plac e de son emplacement d installation original f si l unit est utilis e pour aui
11. ll alternate between CHARGED and CHARGING Q Finally the LED s quit alternating and the CHARGED LED came on but every once ina while the CHARGING LED comes on for just a second or two then goes out Is my system O K A Yes No need to worry It is normal for a battery to lose some of its charge decay when idle Our _ charging system monitors the charge state and turns itself on to boost the battery backup to its optimum charge This usually takes from a few seconds to a few minutes Q We came home late one evening and heard our battery back up alarm sounding The pump wasn t running What s wrong A It is possible that the primary pump failed to operate when needed and your back up pump activated and drained the tank The alarm activates any time the pump is called to operate It continues to operate until the alarm condition is manually acknowledged by pressing the reset switch Q Pressing the reset switch didn t silence the alarm now what A The alarm circuit is activated so long as the float switch is activated Check to see if the back up float switch is tangled or caught in the sump or piping Remember to disconnect all power before servicing Q The float wasn t tangled but the alarm continues to pulsate A A pulsating alarm is different from a steady tone The pulsing alarm indicated that the battery voltage has dipped below an acceptable level As a precaution the cha
12. ly install operate or maintain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and the parts used in connection with such service d fo units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other than for what it was designed and manufactured PRODUCT IMPROVEMENTS SHUR DRI reserves the right to change or improve its products or any component without obligation to provide such a change or improvement for units previously sold and or shipped POSSIBLE CAUSES Installing the pump at an angle prevents air from entering the system If air were allowed to enter the system the pump would not operate Whatisatrickle A trickle charger is a device that allows the battery to charge the pump system by con charger stantly releasing tiny charges until the battery is fully charged Yes However your sump basin must be at least 18 in diameter and a additional piece of PVC pipe must be used to extend the pump tee so the back up pump will not interfere pedestal sump pump f with the float rod of the pedestal pump There are several reasons why this situation might occur A The system is air locked Make sure the pump is positioned at the recommended 30 degree angle B Your battery is
13. ndaires et il est donc possible que la restriction ci dessus ne s applique pas vous Cette garantie vous accorde des droits juridiques pr cis Vous pouvez avoir d autres droits selon la l gislation en vigueur dans votre Etat En l absence d une preuve suffisante tablissant la date d achat la date d expiration de cette garantie sera bas e sur la date de fabrication Envoyer tous les avis etc Product Warranty and Return Dept SHUR DRI B P 9138 269 Trillium Drive Kitchener Ontario N2G 4W5 Shur Dri B P 9138 269 Trillium Drive Kitchener Ontario N2G 4W5 Printed in U S A 2 01 25581A015C TEL 519 748 5470 FAX 519 748 2553 Canada uniquement
14. pump You may need to modify or replace your sump if it is too small A minimum 30 deep sump is recommended Remem ber the back up pump must also be tilted at a 30 degree angle to operate properly It may air bind if not tilted DRRR ANIR Most often Asked Questions about Battery Back up Sump Pumps QUESTION Why is it necessary to install the pump at an angle Can a back up sump pump be used with a The pump is buzzing but not pumping What s wrong What type of battery should be used LIMITED WARRANTY SHUR DRI will repair or replace for the original user any portion of a new SHUR DRAI product which proves defective due to materials or workmanship of SHUR DRI Contact the nearest authorized SHUR DAI dealer for warranty service SHUR DRI shall possess the sole right to determine whether to repair or replace defective equip ment parts or components THIS WARRANTY DOES NOT COVER DAMAGE DUE TO LIGHTNING OR OTHER CONDITIONS BEYOND THE CONTROL OF SHUR DRI PUMPS Warranted 12 months from date of purchase or 18 months from date of manufacture Receipt and product date code required for warranty claim LABOR amp COSTS SHUR DRI shall IN NO EVENT be liable for the cost of field labor or other charges incurred by any customer in removing and or reaffixing any SHUR DRI product part or component THIS WARRANTY WILL NOT APPLY a to defects or malfunctions resulting from failure to proper
15. r exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state In the absence of suitable proof of this purchase date the effective date of this warranty will be based upon the date of manufacture Direct all Notices ete to Product Warranty and Return Dept SHUR DRI 1101 Myers Parkway Ashland OH 44805 1969 Shur Dri 1101 Myers Parkway Ashland Ohio 44805 1969 1 800 535 4950 U S A only Printed in U S A 2 01 25581A015 4 7 PARTS LIST A g 12 VOLT SYSTEM MODEL SD BSP _ Battery not included RE soc a SS Description Req d 6 Level Control 1 2496385068 8 Cable Nylon Tie Not Shown 17190A012 Battery Clamp Not Shown 24963B509A NECETO4ANAC Les questions les plus demand es sur les pompes d appoint de puisard a batterie QUESTION Pourquoi est il n cessaire d installer la pompe de biais la pompe ne fonctionnerait pas Est ce qu une pompe puisard d appoint peut tre utilis e avec une pompe puisard colonne La pompe fonctionne mais elle bourdonne Que se passe t il Quel type de fusible utiliser Quel type de batterie utiliser GARANTIE LIMIT E SHUR DRI r parera ou remplacera pour l utilisateur original toute partie d un nouveau produit Shur Dri qui s av re d fectueux en ra
16. re chose que ce pour quoi elle a t con ue et fabriqu e AM LIORATIONS DE PRODUIT SHUR DR 8e r serve le droit de modifier ou d am liorer ses produits ou leurs composants sans tre oblig d assurer une telle modification ou une telle am lioration aux unit s vendues ou exp di es auparavant CAUSES PROBABLES L installation de biais de la pompe emp che l air de s infiltrer dans le syst me Si cela se produisait Un chargeur faible d bit est un dispositif permettant la batterie de charger le syst me de la nfimes charges jusqu ce que la batterie soit recharg e bloc Oui Toutefois le bassin d ass chement doit mesurer au moins 18po de diam tre et il faut utiliser un bout de tuyau en PVC suppl mentaire pour prolonger le t de la pompe de fa on que la pompe d appoint ne nuise pas au fonctionnement de la tige flotteur de la pompe colonne Qu est ce qu un chargeur faible d bit pompe en lib rant constamment a Plusieurs causes peuvent tre l origine du probl me A Il y a un bouchon d air dans le syst me S assurer que la pompe est positionn e l angle recommand de 30 B La charge de la batterie est basse Si le voyant de LOW de la batterie est allum sur le panneau de commande s assurer que la batterie est correctement charg e C Le syst me peut tre engorg de d bris S assurer que les tuyaux ne sont pas obstru s et que les ouvertures de la pompe sont d gag es
17. rging circuit is locked out when this occurs just in case one or more cells have shorted It will be necessary to remove the battery and have it charged on a commercial automotive or marine battery charger per the manufacturer s instructions Once the battery voltage can be sustained above 11 9 VDC the battery can be re installed in the system and the on board charging circuit can again be used to maintain the battery charge Q When got my system home and prepared to install it found out that the pump cabie sensor and charging cord were too short to reach the control box Can I splice the leads so that they will reach A Don t even think about it The cable lengths were all designed around optimum operating parameters and are at a maximum length for their given sizes Since the charger and pump are microprocessor computer controlled changing the cable lengths may affect critical computer inputs which could cause the system to malfunction and may even present a fire hazard Q couldn t install my battery back up pump above my primary pump per your instructions because my sump is too shallow Will it matter if it is installed BESIDE my primary pump A You bet Installing a back up pump in the sump beside the primary pump could spell disaster Sediment will accumulate inside the back up pump and may cause it to fail when needed most The back up pump must be installed above the normal turn on level of the primary