1. Flex to Ridgid Adaptor Fireplace Fireplace ES ES p Ec Horizontal Wall Vent Terminations The position of the horizontal vent termination must be positioned in such a way as to meet all local building codes Attach the correct length of pipe Mark the center line of the pipe facing the wall allowing for a 1 4 rise per foot of horizontal example 10 ft of horizontal would require a rise of 2 5 ALLOWING THE VENT PIPE TO SLOPE DOWN TOWARDS THE VENT TERMINATION COULD CAUSE POOR COMBUSTION AND OR HIGH TEMPERATURES THAT MAY PRESENT A FIRE HAZARD PERMETTRE LA tuyau de ventilation vers descendent vers la sortie de ventilation POURRAIT PROVOQUER une mauvaise combustion et ou de temp ratures lev es qui peuvent pr senter des risques d incendie Page 32 of 60 OUTER PIPE 7 WALL THUMBLE 9 11 X11 MIN OPENING Safety Cage Mark a 11 x 11 square around the center mark inside dimensions Cut and frame the exterior wall to accept the wall thimble Install the wall thimble on the inside of the exterior wall shield using wood screws Attach the venting to the termination using sheet metal screws for Z Flex installations an Inca Metal Cutting s termination part IMC1070A or IMC1070B shall be used and when using Simpson Dura Vent or Security Venting a Simpson Dura Vent termination part P574 shall be used If termination is to be installed
2. 1 Improper ignition 2 Poor connections at starter and ignition electrode 3 Broken ceramic cover on ignition electrode 4 Battery power low or dead B No gas or low gas pressure 5 Gas line shut off s may not be turned on 6 Airin gas lines 7 Gas lines may not be connected 8 Low pressure may be caused by bent line A Thermocouple Valve 1 Weak or improperly located pilot flame 2 Defective thermocouple 3 Thermocouple not properly installed 4 Open wire connection in pilot circuit 5 Defective Valve B Defective safety circuit 1 Loose or defective connections A Valve Switches 1 Valve control off 2 Blockage at the burner line orifice or ports 8 Defective remote 1 Align the electrode with 1 8 gap to pilot hood 2 Reconnect if loose 3 Replace pilot assembly 4 Replace batteries 5 Turn on shut off valves 6 Purge gas lines 7 Connect all gas lines 8 Check for a kinked line 1 Adjust and clean pilot The flame must impinge on or engulf the thermocouple as shown in Figure 27 2 Replace thermocouple 3 Make sure all wire connections at the gas valve terminals are tight and the thermocouple is fully inserted into the mounting bracket 4 Check wire continuity and connections in the pilot circuit 5 Check with your voltmeter 1 Check continuity tighten wiring or connections and repair 1 Turn to ON position 2 Check and clean 3 Conduct
3. 3 m horizontally L Clearance above paved sidewalk 7 ft 2 13 m T or paved driveway located on public property M Clearance under veranda 12 in 30 f porch deck or balcony 5 CLOSED FIXED AREA WHERE TERMINAL IS NOT PERMITTED a b In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code In accordance with the current ANSI 7223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor For clearances not specified in ANSI 7223 1 NFPA 54 or CSA B149 1 one of the following shall be indicated A minimum clearance value determined by testing in accordance with section 2 23 5 or A reference to the following footnote Clearance in accordance with local installation codes and the requirements of the gas supplier Page 36 of 60 3 3 5 Glass Installation Installation de verre Burn medium positions are critical to the safe and clean operation of this appliance Never add any other material into the firebox Use only with burn medium supplied with this unit Burn positions moyennes sont critiques pour le fonctionnement s r et propre de cet appareil Ne jamais ajouter d autres mat riaux dans le foye
4. Figure 10 ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING CLEARANCES ETC MAY VARY FROM STATE TO STATE PROVINCE TO PROVINCE TOUJOURS v rifier les codes locaux avant l installation VENTILATION ETC D GAGEMENTS peut varier d TAT PROVINCE CONSULT DURAVENT PARTS LIST OR INCA METAL CUTTING S FIREPLACE MANUFACTURING PARTS LIST FOR PART NUMBERS FOYER Duravent CONSULT LISTE DES PI CES OU COUPE METAL INCA de fabrication LISTE DES PI CES DE R F RENCE NOTE See section 3 3 4 Venting for instructions on how to connect Security or Dura vent venting Page 34 of 60 Termination above Roof Consult local codes for minimum vent cap height above the roof X vent must be a minimum of 2 from any wall Minimum Height To prevent water seepage install the flashing with upper portion under the roofing material and the lower portion over the roofing material Note Do not fasten down until the final adjustments to the vent have been made The diagram at right shows the minimum clearances as per the chart on page 36 3 00 Page 35 of 60 V VENT TERMINAL air SUPPLY INLET US Installations Canadian Installations A Clearance above grade veranda porch deck or balcony 12 in 30 cm 12 in 30 cm B Clearance to window or door that may be opened 6 in 15 cm for appliances 10 000 Btuh 3 kW 12 in 30 cm fo
5. b When the Continuous Pilot switch is in the OFF position and the appliance ON OFF switch is turned to ON the pilot will spark and light When the appliance ON OFF switch is turned OFF the pilot will shut off when the main burner shuts off c When the Continuous Pilot switch is in the ON position and the appliance ON OFF switch is turned on the pilot will spark and light When the appliance ON OFF switch is turned to OFF the pilot will stay ON when the main burner shuts off This setting is generally used in cold climates to keep the firebox warm d The Continuous Pilot mode can also be activated by an optional hand held remote control 2 Remote Control Feature The AF 4000 module has a built in remote control receiver This allows the user to program a hand held remote transmitter wireless wall mount thermostat or wireless wall mount switch to the appliance at any time during or after the installation of the appliance a There is a switch located on the side of the AF 4000 module that reads REMOTE OFF b When the Remote Off switch is in the OFF position the appliance will operate from an appliance mounted rocker switch or wall switch connected to the 2 brown wires on the AF 4000 module c When the Remote Off switch is in the REMOTE position the appliance will operate from the Remote Control transmitter wireless wall mounted thermostat or wireless wall mounted switch NOTE The AF 4000 module must be programmed to the Remote Control tr
6. H 11 2 Feet Max Test Condition NOTE All vent dimensions are measured from the appliance surface where the vent connects to the point where exhaust Test Condition B gases exit the termination REMARQUE Toutes les dimensions sont mesur es partir d a ration de la surface de l appareil o l vent se connecte au point o les gaz d chappement de sortie de la r siliation Page 29 of 60 NC pepe p p DE b REA EEFIN LIT EN T IEEE PO UN RET 7 24 Maximum Vertical 2 1 Horizontal 5 Example Where A A And Page 30 of 60 USE OF SEALANT Sealant is required on vent system joints figure 7 On longer vent runs especially vertical runs sealant will ensure that the combustion air enters from outdoors and not through the vent joints Use high temperature sealant available from local suppliers on the inner pipe joint applying the sealant around the outside of the male part of the vent A bead of silicone should be used on the outside of the joint after assembly to seal the supply air If the venting is disconnected for servicing be sure to follow above instructions for resealing venting when reconnecting to system A minimum clearance to combustibles must be maintained around the vent pipe of 1 on all horizontal and vertical pipe runs Un d gagement minimum aux mat riaux combus
7. attire do Er Ve a ia Cm p Tv aat er ces dtu 47 50 6 0 REP ACEMENT PARIS chere o ERE EUN MT mE uetus 51 T0 WARRANTY iode cte e Pa ptr LO ITE e otia teal te Ep Ee o 52 54 8 0 LABEL INFORMATION ssh Roa Ree e E ern e Hao Fete dense 55 56 APPENDIX A INTERMITTENT PILOT amp VALVE 57 60 Table of Contents Page 3 of 60 INSTALLER Leave this manual with the INSTALLATEUR Laissez cette notice avec appliance l appareil CONSUMER Retain this manual for future CONSOMMATEUR Conservez cette notice reference pour consultation ult rieure WARNING e Read this owner s manual carefully and completely before trying to assemble operate or service this fireplace Follow instructions for proper installation e Failure to install this appliance per the manufacturer s instructions or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Any change to this fireplace or its controls can be dangerous e Improper installation or use of this fireplace can cause serious injury or death from fire burns explosions electrical shock and carbon monoxide poisoning Lisez ce manuel attentivement et compl tement avant d essayer de monter utiliser ou entretenir ce foyer Suire les instructions pour assurer une bonne installation Risque de dommages ou de blessures si l appareil n est pas i
8. g ts mat riels des blessures graves ou la mort Page 17 of 60 Electrical Plug Figure 2 Variable Speed 110 volt Fan Blower White neutral Black hot O Thermal Switch Green ground Fan Swith E es Speed Controller Ground Lug Page 18 of 60 3 0 INSTALLATION 3 1 INSTALLATION amp SAFETY NOTES NOTES D INSTALLATION ET DE SECURITE Read all instructions before starting installation and follow them carefully during installation to ensure maximum benefit and safety Failure to follow these instructions will void your warranty and may present a fire hazard See the warranty at the back of this manual for disclaimers regarding improper installation This direct vent fireplace and it s components are tested and safe when installed in accordance with this installation manual Lisez toutes les instructions avant de commencer l installation et de les suivre attentivement lors de l installation pour assurer un b n fice et une s curit maximales Le non respect de ces instructions annule la garantie et peut pr senter un risque d incendie Voir la garantie l arriere de ce manuel pour d charges de responsabilit concernant une mauvaise installation Ce foyer vacuation directe et ses composantes sont test s et s rs lorsqu il est install conform ment aux instructions de montage RNG Do not connect 120 VAC to the gas control valve or it s components
9. 2 HEAT OUTPUT ADJUSTMENT The valve supplied with the appliance has a HI LO knob to control the heat output and flame height see valve diagram in Lighting Instructions section 2 1 2 3 FAN OPERATION For units equipped with a fan control knob the knob is located in the valve control compartment and may be adjusted to the following settings OFF Turn the control fully counter clockwise until the switch operates Variable Speed Setting Turn the control to the desired setting When the knob is turned fully clockwise the fan will set to minimum speed Electrical Grounding Instructions Instructions la terre lectrique This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Cet appareil est quip d une broche de trois terre pour votre protection contre les risques d lectrocution et doit tre branch e directement sur une prise trois broches r ceptacle Ne pas couper ou enlever la terre volets de cette fiche Installation of any type of filter on the fan is not admissible and could WARNING result in a fire explosion property damage serious personal injury or AVERTISSEMENT death L installation de tout type de filtre sur le ventilateur n est pas recevable et pourrait provoquer un incendie d explosion des d
10. NOT BE PLACED ON OR NEAR THE APPLIANCE KEEP THE ROOM AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS PLEASE READ THIS MANUAL BEFORE INSTALLING OR USING THIS APPLIANCE SAVE THIS MANUAL FOR FUTURE REFERENCE Page 1 of 60 DV TASMAN FOYER LINEAR AU GAZ NATUREL Manuel D installation et Guide de l utilisateur AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONN ES DANS CETTE NOTICE POUR R DUIRE AU MINIMUM LE RISQUE D INCENDIE OU D EXPLOSION OU POUR VITER TOUT DOMMAGE MAT RIEL TOUTE BLESSURE OU LA MORT Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquids inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ pas tenter d allumer d appareil e Ne touchez aucun interrupteur Ne pas vous servir des telephones se trouvant dans le b timent o vous vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSEMENT Une mauvaise installation de r glage la modification de services ou de maintenance peut causer des dommages corporels ou mat riels Reportez vous ce
11. a continuity test or jumper wire test and replace if defective check batteries Page 49 of 60 4 Defective wiring or connections 4 Conduct a test with a jumper wire repair as required 5 Defective Valve 5 Contact service technician Ii Soot deposits 1 Air inlet blocked or restricted 1 Clean air inlets 2 Vent system is restricted or 2 Confirm venting amp termination are those inadequate which are approved with the appliance 3 Logs are sooting up 3 Check manual for correct log placement V Flame burns blue and lifts off burner 1 Insufficient combustion air being 1 Ensure that no foreign material blocks air supplied inlets Ensure the vent is adequate 2 Manifold pressure set too high 2 Check manifold pressure 3 Vent system restricted 3 Check vent system VI Main flame does not burn 1 Incorrect vent or termination 1 Confirm venting amp termination are those properly used which are approved with the appliance VII Flames impinge on firebox 1 Vent system is restricted or 1 Correct flue as required top inadequate 2 Manifold pressure too high 2 Check manifold pressure as required Page 50 of 60 6 0 REPLACEMENT PARTS When requesting service or replacement parts for your unit please provide model name and serial number All parts listed below may be ordered from an authorized dealer Description Part Door IMC512 Burner IMC514 Fan IMC542 Door Glass IMC528 Restrictor IMC524 Door Glass Gaske
12. as this will damage the valve Ne pas communiquer 120 VAC a la valve de contr le du gaz ou de ses composantes car cela endommagerait la vanne 3 2 UNPACKING Please check the appliance carefully for any damaged or missing components specifically check the glass condition Report any problems to your dealer within 30 days of purchase 3 3 INSTALLATION For satisfactory results it is necessary to plan certain aspects of the installation prior to the appliance s final positioning These include the vent system the gas piping and the fans wiring Combustible surfaces such as the hearth mantle and facing must also be planned for Be sure to leave adequate clearance for servicing and proper operation Pour des r sultats satisfaisants il est n cessaire de planifier certains aspects de l installation avant le positionnement final de l appareil Il s agit notamment du syst me de ventilation les canalisations de gaz et le c blage fans surfaces combustibles tels que le foyer le manteau et en face doivent galement tre pr vues pour N oubliez pas de laisser un espace suffisant pour l entretien et bon ALL INSTALLATIONS REQUIRE VENTING Vented Gas Fireplace Not for Use with Solid Fuel TOUTES LES INSTALLATIONS exigez l a ration Foyer au gaz evacuation Ne pas utiliser avec du combustible solide Page 19 of 60 3 3 1 MINIMUM CLEARANCES D GAGEMENTS E 33 500 0 000 38 000 Framing Dimensions 38 wide
13. e Rel chez le bouton et il sauvegarder Veilleuse doit rester allum e Si elle s teint r p tez les tapes 4 7 Si le bouton ne fait pas apparaitre m me arr tez et appelez imm diatement votre technicien ou votre fournisseur de gaz e Sile pilote ne reste pas allum e apr s plusieurs tentatives tournez le bouton de contr le du gaz OFF et appelez votre technicien ou votre fournisseur de gaz 9 Tourner le bouton de contr le du gaz antihoraire O sur ON R tablissez l alimentation lectrique de l appareil R glez le thermostat la temp rature d sir e ou tournez le commutateur appareil pour position ON persienne inf rieure puis fermez 1 R glez le thermostat r glage le plus bas 2 Coupez l alimentation lectrique de l appareil si le service doit tre ex cut 3 Poussez le bouton de contr le du gaz et tourner dans le sens horaire sur OFF ne forcez pas Remarque La vanne est quip e d un verrouillage de s curit une fois dans la position OFF vous devez attendre que la thermopile a refroidi avant de tenter d allumer la veilleuse environ 3 minutes m D GR D N Main Control Knob Manitold Pressure Top N i ES Hi Low Adjustment Knob Gas Inlet El We BEL 1 4 MON X Thermocouple N Thermopile Connections N Inlet Pressure Tap Gos Duler Pilot Adjustment screw Page 16 of 60 Robertshaw 9A0A68A6A 2
14. equipped with a fan control the knob controls the fan speed turning the knob counter clockwise turns it to the Off position Gas control Optional Gas control valve type Automatic millivolt powered combination gas control valve with variable flame control for convenience and on off switch Optional digital remote on off wall switch and or optional wall thermostat note thermostats are not allowed in the United States The gas valve does not require electricity from an external source Electronic Valve Optional Automatic DC valve with AC power adapter Hand held remote control Fan control Optional Variable speed control For units equipped with a fan control adjust speed by remote control settings 1 6 Supreme Remote Control Functional Operation Matrix Initial Setup Installation of 2 AAA size batteries will activate the setup mode Setup mode can also be activated by pressing the FLAME REAR and PROG TIME buttons simultaneously for 5 seconds The control will exit setup mode if no button is pressed for 20 seconds Appropriate icon on LCD will flash when ready for setup Press the UP or Down button in setup mode to change the temperature scale Press SET button to skip or advance to Fuel Type setup Press the UP or DOWN button to switch control from Natural to LP or LP to Natural Gas Press SET button to skip or advance to Clock setup Press the UP or Down Button to set the hour Press SET to advance to minutes P
15. flame to properly engulf the thermopile If so adjust and reset If voltage is still insufficient replace thermopile 9 Wall switch thermostat or 9 Follow previous corrective action check wires are defective switch and wiring Replace where defective Soot deposits glass 1 Air inlet blocked or restricted 1 Clean air inlets 2 Vent system is restricted or 2 Confirm venting amp termination are those inadequate which are approved with the appliance V Flame burns blue and lifts off burner 1 Insufficient combustion air 1 Ensure that no foreign material blocks air being supplied inlets Ensure the vent is adequate 2 Manifold pressure set too high 2 Check manifold pressure 3 Vent system restricted 3 Check vent system VI Main flame does not burn 1 Incorrect vent or termination 1 Confirm venting amp termination are those properly used which are approved with the appliance Vil Flames impinge on firebox 1 Vent system is restricted or 1 Correct flue as required top inadequate 2 Manifold pressure too high 2 Check manifold pressure as required Page 48 of 60 TROUBLE SHOOTING INTERMITTENT PILOT SYMPTOM l Pilot will not light after repeated triggering of the remote control intermittent pilot Pilot will not stay lit after following the lighting instructions Main burner will not light POSSIBLE CAUSE CORRECTIVE ACTION A No spark at electrode weak or not heat source for pilot ignition
16. hooked a fork connector to each wire and attach them to the TH TP and TH screws located on the valve Apr s que l unit est install e et la conduite de gaz accroch sertir un connecteur fourchette pour chaque fil et les joindre la vis TH TP et TH situ sur la valve Check tests can be performed on the valve by using the trouble shooting guide Section 5 0 V rifiez les tests peuvent tre effectu s sur la valve en utilisant le guide de d pannage la section 5 0 This switch may be connected in parallel with a thermostat digital on off remote or wall switch see Figure 4 Ce commutateur peut tre connect en parall le avec un thermostat num rique t l commande marche arr t ou un interrupteur mural voir Figure 4 Figure 4 Wall Switch Thermostat Thermopile Thermocouple VENT PILOT ADJ Page 25 of 60 3 3 4 DIRECT VENT INFORMATION DIRECT VENT D INFORMATION The unit must be connected to listed 2 ply aluminium venting 4 flex vent on the exhaust side and listed 7 flex vent on the air intake side or can be used with Security Venting or Simpson Dura Vent 4 x 6 5 8 with the use of Simpson Dura Vent adapters part s 0924N3 amp P574 Install the vent components according to the manufacturer s instructions being sure to use spacers
17. is located in the control compartment at the bottom of the unit For your convenience the unit can also be operated by a thermostat a digital on off remote or a wall switch control Millivolt thermostats are available from any authorized Inca Metal Cutting dealer Bedroom installations require the use of a wall thermostat Note Thermostats are not allowed in the United States Le bouton de commande du br leur est situ dans le compartiment de commande au bas de l appareil Pour votre commodit l appareil peut galement tre exploit par un thermostat un appareil photo num rique on off distance ou une commande de l interrupteur mural Thermostats millivolts sont disponibles depuis n importe quel revendeur agr Inca Metal Cutting Chambre installations n cessitent l utilisation d un thermostat mural Remarque Les thermostats ne sont pas autoris s aux Etats Unis The thermostat digital on off remote or wall switch MUST be rated for millivolt use Minimize splicing in all millivolt wiring amp crimp all unavoidable splices Le thermostat num rique t l commande marche arr t ou l interrupteur mural doit tre valu pour une utilisation en millivolts Minimiser pissage dans l ensemble du c blage millivolt amp sertir toutes les pissures in vitable NOTE Thermostat Digital On Off Remote or Wall Switch Installation Mount the thermostat digital on off remote or wall switch in the desired location and run two c
18. laque la fin de la chemin e de peinture ou laque doit tre r sistante la chaleur jusqu 2500 F pour pr venir la d coloration z 2 T Og Page 21 of 60 Heat Baffle fixed to non combustible board by manufacturer see diagram next page for side view Non combustible board supplied by manufacturer 96 000 7 88 000 7 NOTE STUD MUST BE INSTALLED ON EDGE AS SHOWN IN THIS DIAGRAM The closest combustible material above the fireplace must be a minimum of 33 50 from the floor with the stud laying on edge as shown above Le plus proche mat riau combustible au dessus du foyer doit tre un x minimum de 33 50 a partir du sol avec le goujon pose sur le bord comme indiqu ci dessus Page 22 of 60 NON COMBUSTIBLE MATERIAL NON COMBUSTIBLES Non combustible material will be supplied by the manufacturer This must be installed on top of the fireplace as shown above to meet installation codes Heat baffle will be installed to non combustible board by manufacturer Mat riaux non combustibles seront fournis par le fabricant Ce doit tre install sur le dessus du foyer comme indiqu ci dessus pour r pondre aux codes d installation D flecteur sera install la non combustibles par le constructeur SIDE VIEW OF TOP NON COMBUSTIBLE B
19. see Figure 5 every 5 to ensure correct spacing is maintained between air intake and exhaust Slope horizontal pipe at least 1 4 6 mm rise per foot of horizontal run Allow 1 25 mm clearance to the vent Refer to the graph for allowable vent configurations Be sure to ensure that termination area allows enough room for adequate combustion and ventilation air and that the flow of combustion and ventilation air is not obstructed L unit doit tre raccord e l aluminium 2 plis num r s ventilation 4 flex vent sur le c t de l chappement et num r s 7 flex vent sur le c t d admission d air ou peut tre utilis avec la s curit d vacuation ou de Simpson Dura Vent 4 x 5 6 8 avec l utilisation d adaptateurs Simpson Dura Vent partie 5 amp P574 0924N3 Installer l vent composants selon les instructions du fabricant en veillant utiliser des entretoises voir Figure 5 tous les 5 pour assurer l espacement appropri est maintenu entre l apport d air et d chappement Pente du tuyau horizontal d au moins 1 4 po 6 mm mont e par pied de conduit horizontal Autoriser 1 po 25 mm l vent Reportez vous au graphique pour admissibles vent configurations Assurez vous de faire en sorte que zone de terminaison permet suffisamment de place pour la combustion et la ventilation ad quate et que le flux d air de combustion et la ventilation n est pas obstru e If at any time the vent air intake piping is di
20. 1 WARNING AVERTISSEMENT BE CERTAIN TO CHECK FOR GAS LEAKS AT ALL GAS CONNECTIONS AFTER REINSTALLATION OF VALVE IL EST INDISPENSABLE DE V RIFIER LES FUITES DE GAZ A TOUS LES CONNEXIONS DE GAZ APRES LA REINSTALLATION DE LA VANNE Page 44 of 60 4 0 4 1 MAINTENANCE SAFETY WARNING AVERTISSEMENT TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO 30 MINUTES BEFORE SERVICING COUPEZ LE GAZ AU BR LEUR PRINCIPAL ET LAISSEZ L APPAREIL REFROIDIR PENDANT JUSQU 30 MINUTES AVANT L ENTRETIEN Service and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service technician More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is important that the access door compartment burner and circulating air passageways be kept clean to provide for adequate combustion and ventilation airflow Do not substitute materials or use components other than factory supplied 4 2 RECOMMENDED SERVICE 1 The venting system should be annually inspected by a qualified agency 2 Visually check the burner and pilot flames occasionally Visually inspect height and color of flames 3 Clean the glass as needed See section 4 3 for instructions on glass cleaning 4 Have the appliance inspected annually by a professional service technician 5 Clean the appliance regularl
21. DIX A Continued 6 Volt DC Adaptor Power Connection 8 Pin IPI Connection fem idi Pilot Connections Leam Button AUX Connection Remote Frequency Adjustment Screw Remote OLF Switch Pilot Connection Continuous Pilot 7S Pilot Connection OFF ON Switch Page 58 of 60 APPENDIX A Continued Special Features on the AF 4000 System The AF 4000 Module can be powered two different ways The first is a standard 110 volt AC to 6 0 volt DC adaptor This adapter is connected to the AF 4000 Module by connecting the two 1 4 female terminals from the adapter to the two 1 4 male terminals located on the AF 4000 Module marked POWER The second method of powering the appliance is by using the AF 4000 BP battery pack The appliance will not have back up power during power outages if only the 6 0 volt adapter is used however a battery back up package AF 4000BBU is available to be used in this situation The AF 4000 module has 2 special features built into the system Please check with local City codes regarding the use of the following feature 1 Continuous Pilot Feature This feature allows the user to change from a spark to pilot system to a standing pilot system for direct vent appliances during cold climate to keep the firebox warm There is a switch located on the side of the AF 4000 module that reads Continuous Pilot ON OFF this switch will allow the user to select the pilot mode of operation
22. ION FORT 3 5 w c 0 87 kPa MANIFOLD PRESSURE Lo COLLECTEUR DE PRESSION FAIBLE 1 7 w c 0 42 kPa GAS INLET SUPPLY PRESSURE ENTREE DE PRESSION Minimum 5 0 w c 1 2 kPa Maximum 13 5 w c 3 4 kPa ORIFICE SIZE 9 0 4500 43 DMS FORMAT D ORIFICE VALVE ORIFICE 9 0 4500 51 DMS SOUPANGE D ORIFICE AIR SHUTTER OPEN 1 8 min VOLET DE L AIR 8 175mm CONTROL VALVE TYPE Skytech AF 40004 TYPE DE SOUPAPE Robertshaw VENTING 2 ply aluminum vent VACUATION Simpson Duravent or Security Venting FAN Variable Speed 120 Volt VENTILATEUR THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH ANY OTHER GASES CET APPAREIL DOIT ETRE UTILISE UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUE SUR LA PLAQUE SIGNALETIQUE CET APPAREIL NE PEUT ETRE CONVERTI A D AUTRES GAZ Page 6 of 60 APPLIANCE DIMENSIONS Figure 1 34 133 17 134 1 14 416 INSTALLATION CODES This appliance is a Direct Vent appliance which draws all combustion air from outside the building through an intake vent pipe Installation must conform to local codes In the absence of local codes installation must conform to the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the current Natural Gas and Propane Installation Code B149 1 The unit when installed must be ele
23. MENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE VOTRE FOURNISSEUR DE GAZ z E 2 lt 1 Remove lower access panel from in front of door Remove the door as in 3 3 6 Retirez du panneau d acc s inf rieur en face de la porte Enlevez la porte comme dans 3 3 6 2 Remove the burner pan by undoing the screws at front and back of pan Remove the burner carefully rocks can be left on pan if removal is done with care Retirer la casserole du br leur en d vissant les vis l avant et l arri re du po le Retirez le br leur avec soin roches peuvent tre laiss s sur po le si l enl vement est fait avec soin Page 41 of 60 Optional Rock Kit shown X 4 4 3 Remove the access panel in the middle of the firebox just in front of the burner Retirez le panneau d acc s au milieu du foyer juste en face du br leur TE 4 The fan is attached with magnets for ease of installation and can be pulled off the rear wall Les fan sont attach s avec des aimants pour la facilit d installation et peut tre retir de la paroi arri re Page 42 of 60 5 Once removed from the wall the fan will slide out through the opening Une fois retir du mur que les fan vont glisser par l ouvertur
24. ND ANRT A TS At ST 17 2 94 FAN Operations a spa Ld ae 17 18 3 0 INSTALLATIONS 3 1 Installation amp Safety Notes 5 EE ERE EIER EHE ELE ep Heer MEE He eU 19 3 2 RE ERE EET EE Aes Aa 19 2 39 Installations co d CERO EQ eus gig aah Fa NUR 19 3 3 1 Minimum Clearances amp Non Combustible Material Requirements 19 23 3 3 2 Line Installation eoi pointe et tesi lik bM eva ir RR 23 3 3 3 Thermostat Wall Switch or Digital On Off Remote 24 25 9 9 4 Direct Vent Inform atom uoo tee 26 36 3 3 5 Glass Installation Rate ne 37 3 3 6 Door Installation tent 38 39 850 atah Ering eH LEE 39 3 30 Manifold PressHlG ei uai ere tentent m Wa eem RM pra eu It 39 9 9 9 Primary Air Iis PAM iiid anc dign 40 41 3 3 10 Altitude PRIUS TCIM EET 41 UN OE 41 43 3 912 Gas Valve nues uma aus 44 40 MAINTENANCE Sn SR tante tenta rtp A MK ritu tenait tn nat ets ttes 4T Maintenance Safety ume b E ere HERE LEN ees ete 45 4 2 Recommended S ries nan nn nt nn int ess 45 3 ass CS xxn na KDE ELT ee 45 4 4 Burner amp Axltuti itt 45 4 5 Valve amp Pilot Replacement iii 46 5 0 TROUBLE SHOOTING
25. OARD heat baffle fixed to non combustible board by manufacturer TOP OF FIREPLACE HERE 3 3 2 GAS LINE INSTALLATION INSTALLATION DE LA LIGNE de GAZ Install supply line using any piping approved for your installation meeting CAN CGA 6 10 AA 3 ANSI 721 24 or Z21 45 A qualified gas fitter should install the gas line in accordance with all local building codes If codes permit coiled copper tubing may be used for gas supply Installez la ligne d approvisionnement en utilisant toute la tuyauterie approuv pour votre r union d installation CAN CGA 6 10 AA 3 ANSI Z21 24 ou Z21 45 Un installateur de gaz qualifi doit installer la canalisation de gaz en conformit avec les codes du b timent locaux Si les codes le permettent tube de cuivre enroul peut tre utilis pour l approvisionnement en gaz Pressure taps are provided on the gas control for test gauge connections to measure the manifold and inlet pressures see Lighting Instructions Les sont fournis sur la commande de gaz pour les connexions prises de pression gabarit d essai pour mesurer les pressions multiples et d une entr e voir les Consignes d allumage This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Cet appareil doit tre isol de l alimentation en gaz en fermant son rob
26. T G N RALE Maintain adequate clearances around air openings into the combustion chamber Respecter les distances minimales convenables autour des bouches d air dans la chambre de combustion Maintain adequate accessibility clearances for servicing and proper operation Respecter les distances minimales d accessibilit suffisante pour l entretien et bon This appliance shall not be connected to chimney flue serving a separate solid fuel burning appliance Cet appareil ne doit pas tre raccord une chemin e desservant un autre appareil br lant des combustibles solides The appliance area must be kept clear and free from combustible materials gasoline and other flammable liquids and vapors La zone appareil doit rester clair et exempt de mat riaux combustibles essence et autres vapeurs et liquides inflammables The flow of combustion and ventilation air shall not be obstructed Le d bit de combustion et de ventilation ne doit pas tre obstru The combustion air supply shall be in the same pressure zone as the drafthood relief opening on an appliance equipped with a drafthood or as the vent outlet on an appliance not equipped with a drafthood L alimentation en air de combustion doit tre dans la zone m me pression que l ouverture de secours hotte air sur un appareil quip d une hotte air ou que l vent de sortie sur un appareil n est pas quip d une hotte air Do not use this appliance if any part has been under
27. TASMAN DV LINEAR FIREPLACE 21 000 BTU Natural Gas Installation and Operating Instructions MODEL BL21 Us CERT LC773211 WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR DEATH Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD
28. VERTISSEMENT THE FOLLOWING PROCEDURE IS TO BE PERFORMED BY QUALIFIED PERSONNEL ONLY TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO 30 MINUTES BEFORE SERVICING LA PROCEDURE SUIVANTE EST EFFECTUER PAR DU PERSONNEL QUALIFIE COUPEZ LE GAZ AU BR LEUR PRINCIPAL ET LAISSEZ L APPAREIL REFROIDIR PENDANT JUSQU A 30 MINUTES AVANT L ENTRETIEN 1 Turn off the gas at the meter 2 Remove the door 3 Remove the burner by loosening the screws and lifting it out see section 3 3 9 If the decorative glass is removed from the burner pan make sure you do not get any medium around the pilot when replacing it 4 Disconnect the gas line to the appliance and disconnect the gas line from the valve to the main orifice 5 Remove the screws holding the valve bracket to the base of the unit and lift valve amp valve bracket out Undo the pilot gas line at the gas valve Disconnect the thermostat or on off switch wires from the valve if applicable Remove the gas line to the valve inlet and outlet Remove the screws which hold the valve to the valve bracket E i 0 Remove the screws fastening the pilot assembly to the pilot bracket and remove the pilot assembly 11 Reassemble the components in reverse order Page 46 of 60 5 0 TROUBLE SHOOTING SYMPTOM Pilot will not light after repeated triggering of the piezo ignition button Pilot will not stay lit after A following the lighting instructi
29. ansmitter wireless wall mounted thermostat or wireless wall mounted switch a To program the AF 4000 locate the LEARN button on the AF 4000 module Press and release the LEARN button the AF 4000 module will beep then press any key on the Remote Control Once the AF 4000 internal receiver accepts the transmitter code there will be a series of confirming beeps b The Remote system is now ready for use 12 2009 Page 59 of 60 APPENDIX A Continued AF 4000 Wiring Diagram Not To Scale gt gt gt gt Lh Main Burner White TO 5 TERMINAL ON MAIN MODULE FROR i TERMINAL ON MAIN MODULE Orange 7 5 Volt 1 Amp Adaptor LIGHT 4 4 Female 14 Male Connector Connector FTR 120V gt 4 4 Female 1 4 Male Extension Connector Connector Module N Communication Wires f Module FROH PILOT FLAME SENSOR paok ip 1 Battery Pack aCe ae D FAN Main Flame 5 Step Oulput 110 Volt Power Supply Inca Metal Cutting Unit 100 11091 Bridgeport Road Richmond BC V6X 1T3 Canada Page 60 of 60
30. ar les conditions environnementales telles que des toits des b timents des arbres proximit des collines des montagnes des vents inad quats des configurations de ventilation excessive l insuffisance des pressions d air d air d appoint ou n gatives qui peuvent ou peut ne pas tre caus s par des syst mes m caniques tels que les ventilateurs fours les s cheuses etc Les dommages la chemin e chambre de combustion ou pi ce d habillage d autres cause de l eau caus s par des intemp ries de longues p riodes d humidit la condensation des produits chimiques ou de nettoyants dommageables ne sera pas la responsabilit de l Inca Metal Cutting L acte de vente ou sa copie sera requise ainsi que le num ro de s rie et un num ro de mod le lors de toute r clamation aupr s de votre revendeur agr Inca Metal Cutting se r serve le droit d avoir son repr sentant d inspecter tout produit ou pi ce avant d honorer toute r clamation Page 54 of 60 8 0 LABEL INFORMATION Direct Vented Gas Fireplace Inca Metal Cutting Inca Metal Cutting E 100 11091 Bridgeport Road This Fireplace is factory equipped for 0 1370m 0 4500ft Cette chauffrette est equipe en usine pour une elevation de 1370m 0 C US MODEL TASMAN BL21 CERT LC773211 Tested to ANS Z21 88 2009 CSA 2 33 2009 Vented Gas Fireplace Heater Test pour la norme ANSI 721 88 2009 CSA 233 2009 ventil Chemin e Radiateur g
31. az Certified for U S and Canada Certifi pour le Canada ET U S A MODEL TASMAN BL21 NATURAL GAS Gaz naturel Orifice DMS 0 1370m 0 4500 ft 43 DMS Input rating BTU hr Kw 0 1370m 0 4 500 ft Alt 21 000 BTU hr 6 15kw Evaluation de la consommation BTU hr Kw 0 1370 0 4500 d altitude Minimum Input BTU hr Kw 13 000 BTU hr 3 81kw Consommation minimale BTU hr Kw anifold Pressure In w c kPa 35 087 Collecteur de pression In w c kPa Manifold Pressure Lo setting In w c kPa 1 7 10 42 Collecteur de pression bas rendement In w c kPa inimum Inlet Pressure In w c kPa 507 124 Entree de pression minimale In w c kPa This appliance must be installed in accordance with local codes if any if none follow the National Fue Gas Code ANSI 7223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA 149 1 MINIMUM CLEARANCES TO COMBUSTIBLES For more details see instruction Manual NOTE ALL CLEARANCES ARE DETERMINED WHEN FACING THE FRONT OF THE UNIT Unit Trim to Sidewall 6 152 mm 4 Unit sides 2 51 mm standoffs 12 305 mm Mantle at 40 1016 mm from floor 5 Unit back 1 5 38 mm standoffs 2x4 Framing on edge 33 5 851mm from floor to 6 Internal Ceiling 48 1219 mm from floor lower edge of stud Electrical Rating 115 Volts less than 12 Amps 60 Hz DANGER Risk of electrical shock Disconnect power before servicing unit Do not route power
32. bligations and liability of Inca Metal Cutting with respect to the Inca Metal Cutting gas fireplace and any other warranties expressed or implied with respect to this product its components or accessories are excluded Inca Metal Cutting neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product Inca Metal Cutting will not be responsible for over firing downdrafts spillage caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents excessive venting configurations insufficient make up air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to fireplace combustion chamber trim or other component due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of Inca Metal Cutting The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer Inca Metal Cutting reserves the right to have its representative inspect any product or part thereof prior to honoring any warranty claim 7 0 GARANTIE DE PROTECTION Produits Inca Metal Cutting sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s qui sont fiers de le
33. cal length directly on top of the stove 4 90 degree elbows 20 6096 mm maximum horizontal length Wall thimble part IMC1082A Horizontal termination cap 0984 The maximum vertical system consists of Dura Vent adapter Part 0924N3 directly on top of unit Up to 34 10363 mm of vertical length Fire stop Flashing Collar Termination cap part 0991 Security Venting The minimum vent system for horizontal termination must consist of Dura Vent adapter Part 0924N3 directly on top of unit 12 300mm vertical length of vent 90 degree elbow 12 305 mm horizontal length of vent Wall thimble part IMC1082A Horizontal termination cap SV4CHC The maximum horizontal vent system consists of Dura Vent adapter Part 4 0924N3 directly on top of unit 34 10363 mm vertical length directly on top of the stove 4 90 degree elbows 20 6096 mm maximum horizontal length Wall thimble part IMC1082A Horizontal termination cap SVACHC The maximum vertical system consists of Page 27 of 60 Dura Vent adapter Part 0924N3 directly on top of unit Up to 34 10363 mm of vertical length Fire stop Flashing Collar Termination cap part SVACGV Use a ceiling fire stop when penetrating a ceiling or floor Use a wall thimble when penetrating an inside or outside wall Vent terminals shall not be recessed into a wall or siding 2 Ply Aluminum Flex Vent The minimum vent system for horizontal termination must consist of 12 305 mm vertical le
34. cord beneath heater FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY VENTED GAS FIREPLACE NOT FOR USE WITH SOLID FUEL CAUTION Hot while in operation Do nottouch Severe burns may result Keep children clothing fumiture gasoline and other liquids having flammable vapors away WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier For use with listed aluminum 2 ply venting Security Venting or Simpson Dura Vent For venting configurations please see manufacturers manual and check with local building codes Page 55 of 60 8 0 LABEL INFORMATION continued Sections of the venting system have not been installed WARNING Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer s instructions Des sections du syst me d vacuation n ont pas t install es AVERTISSEMENT Ne pas utiliser l appareil tant que toutes les sections n ont pas t assembl es et install es selon les instructions du fabricant WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three
35. ctrically grounded in accordance with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 or with the current Canadian Electrical Code CSA C22 1 n the state of Massachusetts this product can only be installed by a licensed plumber or a licensed gas fitter Failure to comply will void the warranty This appliance has been certified for use with natural gas This appliance is not for use with solid fuels CODES D INSTALLATION Cet appareil est un appareil vent direct qui attire tous l air de combustion provenant de l ext rieur du b timent par une entr e d vent L installation doit se conformer aux codes locaux En l absence de codes locaux l installation doit tre conforme au National Fuel Gas Code ANSI 2223 1 NFPA 54 ou le gaz naturel actuel et le Code d installation du propane B149 1 L unit une fois install doit tre lectriquement la terre conform ment aux codes locaux ou en l absence de codes locaux avec le National Electric Code ANSI No 70 ou avec l actuel Code canadien de l lectricit CSA C22 1 Cet appareil a t certifi pour une utilisation avec du gaz naturel et le propane Cet appareil n est pas pour une utilisation avec des combustibles solides Page 7 of 60 1 2 FEATURES Ignition system Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter Fan control Optional Variable speed control For units
36. door lock bars down forward and up to secure the door in place Replace lower access strip in front of door Monter en haut de la porte sur les supports porte du haut assurez vous que la porte est centr e sur l appareil Poussez le bas de la porte dans l appareil et tirez le verrou de la porte 2 barres vers le bas vers l avant et s curiser la porte en place Remplacer la bande inf rieure d acc s en face de la porte door bracket door bracket Removal is in reverse order L enl vement est dans l ordre inverse If the glass has been damaged or broken it is highly recommended that you contact a qualified service person Remove the broken pieces be sure to wear gloves and remove door See the replacement parts list at the end of the manual you will require one 5 mm ceramic glass panel with gasket installed Lay in a blob of high temperature silicone in each of the four corners of the door Then follow the instructions above to re install the door Si le verre a t endommag ou cass il est fortement recommand que vous contactez une personne qualifi e Retirez les morceaux n oubliez pas de porter des gants et enlever la porte Voir la liste des pi ces de rechange la fin du manuel vous aurez besoin d un panneau de verre 5 mm en c ramique avec un joint install Laics dans une goutte de silicone haute temp rature dans chacune des quatre coins du cadre de porte et avec le bord arrondi face dans le lieu porte le pan
37. e 6 To replace fan and reassemble the fireplace go in reverse order from steps 5 through 1 Pour remplacer les fan et montons la chemin e aller dans l ordre inverse des tapes 5 1 The pictures at left show the electrical box that controls the fan the power cord attached and the strain relief connected to the box Page 43 of 60 3 3 12 GAS VALVE ACCESSIBILITY ACCESSIBILIT ROBINET DE GAZ TURN THE MAIN GAS amp POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE VOTRE FOURNISSEUR DE GAZ z gt lt ATTENTION 1 Remove the lower access panel from in front of door Remove the door as in 3 3 6 Retirez du panneau d acc s inf rieur en face de la porte Enlevez la porte comme dans 3 3 6 2 Undo the screws on the valve mount brackets at either end of the valve D faire les vis sur les supports de montage robinet chaque extr mit de la vanne 3 Carefully tilt the valve through the opening and lift out of firebox for accessibility Soigneusement incliner la valve travers l ouverture et de sortir de la chambre de combustion pour l accessibilit 4 Replace valve in reverse order from steps through 1 Remplacer la vanne dans l ordre inverse les tapes 3
38. e is to be performed 3 Push in gas control knob slightly and turn clockwise to OFF do not force Note The valve is equipped with a safety lockout once in the OFF position you must wait until the thermopile has cooled before attempting to light the pilot approximately 3 minutes Main Control Knob Manifold Pressure Tap Hi Low Adjustment Knob e Gas Inlet x Thermocouple Thermopile Connections Inlet Pressure Tap as uli N Pilot Adjustment screw Page 15 of 60 2 1 INSTRUCTIONS D ALLUMAGE O POUR VOTRE SECURITE LIRE AVANT D ALLUMER ATTENTION Si vous ne suivez pas exactement ces instructions un incendie ou une explosion entrainant des dommages mat riels des blessures ou des pertes de vie Cet appareil a un pilote qui doit tre allum e la main Lorsque l clairage le pilote suivez ces instructions la lettre AVANT L ALLUMAGE odeur tout autour de l appareil pour le gaz Soyez s r de sentir pr s du plancher car certains gaz sont plus lourds que l air et se d posent sur le sol QUE FAIRE SI VOUS UNE ODEUR DE GAZ e Ne tentez pas d allumer l appareil e Ne pas toucher aucun interrupteur lectrique n utilisez aucun t l phone dans votre difice e Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur de gaz e Si vous ne pouvez pas joindre
39. e ou le mouvement pendant le transport To adjust the air shutter Pour ajuster l obturateur d air 1 Turn off the gas Fermez le gaz 2 Remove the door Enlevez la porte 3 Remove glass from burner Retirez le verre du br leur 4 The burner pan does not need to be removed to adjust the air shutter The burner pan does not need to be removed to adjust the air shutter 5 Undo the set screw on the air shutter and adjust accordingly then retighten the set screw D faire la vis de r glage sur le volet d air et d ajuster en cons quence puis resserrez la vis de r glage Air tube and Air shutter shown removed for clarity purposes only 6 Reassemble the fireplace in reverse order from through 2 Remonter la chemin e dans l ordre inverse de 3 2 7 Turn on the gas Allumez le gaz CAUTION PARTS REQUIRING ADJUSTMENT DURING OPERATION MAY BE HOT QUEUE PIECES NECESSITANT REGLAGE PENDANT LA MARCHE PEUT ETRE CHAUDE Factory Setting Natural Gas 50 Page 40 of 60 Aeration adjustment is important for the correct functioning of the appliance Carbon build up flame lifting or any malfunction due to improper aeration adjustment during installation is not covered under the factory warranty R glage de l a ration est importante pour le fonctionnement correct de l appareil Une accumulation de carbone de levage flammes ou de toute d faillance due une mauvaise a ration d ajustement lors de l ins
40. ears press and release the SET button to set If the SET button is not pressed the set temperature will automatically be set after 5 seconds The Thermostat Mode can be de activated by pressing the MODE button Thermostatic Flame Modulation This control can perform Main Flame Modulation using the Thermostat The control will shut the unit off when the room temperature reaches 2 above set temperature The Thermostat will automatically modulate the main flame Manual Flame Modulation Main Flame To change the Flame Level manually press the FLAME MAIN button The current level will show in the MAIN box on the LCD screen Press the UP or DOWN button to change the Flame Level When the unit is turned on whether in Manual Thermostatic or Program Mode the Main Flame will automatically ignite at the High 7 setting After 5 seconds the flame will default to the previous setting Page 9 of 60 Fan Control The unit must be ON to operate the Fan The Fan will turn on after 5 minutes of operation Once the Fan comes on it can be controlled using the FAN button Press the FAN button and the fan icon and speed will appear on the LCD screen Press the UP or DOWN button to control the fan speed 0 6 Press the DOWN button until O Level is reached to turn the Fan off The fan will run for 12 minutes after the unit is shut off in any mode The fan may not be controlled during this period Continuous Pilot The unit can be changed
41. er OFF sur OFF a 8 D oon Prises de pression Raccordement de la vanne principale Pilote de connexion interne sol noide Ports de sortie Trous de montage Vis de r glage du d bit Connexions pilote High Low Connection 0 Ports d entr e Page 14 of 60 2 1 LIGHTING INSTRUCTIONS oog om x O FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS e Do nottry to light any appliance Do not touch any electric switch do not use any phone in your building e Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions e f you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a q
42. evel Thermal Safety When the internal components of the Main Module reach 170 F the unit will automatically shut off and send a repetitive audible signal The unit can be turned back on when the module cools below 160 Communication Safety When in the Thermostat or Program Mode the transmitter will send a silent signal to the module every 15 minutes If a signal is not received within 2 hours due to dead batteries lost transmitter or transmitter out of range the unit will automatically shut down and the module will send a repetitive audible signal Page 10 of 60 1 3 INTENDED USE USAGE PROPOS This appliance is intended to be used as a zero clearance fireplace This unit is certified for installation in a bedroom or a bed sitting room where the maximum input is within 50 cubic feet per 1000 Btu hr i e 900 cubic feet for E unit amp 1600 cubic feet for H unit In Canada all bedroom installations require the use of wall thermostats note thermostats are not allowed in the United States Cet appareil est destin tre utilis comme un foyer d gagement z ro This unit is certified for installation in a bedroom or a bed sitting room where the maximum input is within 50 cubic feet per 1000 Btu hr i e 900 cubic feet for E unit amp 1600 cubic feet for H unit In Canada all bedroom installations require the use of wall thermostats note thermostats are not allowed in the United States 1 4 GENERAL SAFETY S CURI
43. from Intermittent Pilot Ignition to Continuous or standing pilot To place the unit in continuous pilot mode press and release the PROG TIME and the FLAME MAIN buttons simultaneously Continuous Pilot will appear on the LCD screen Repeat the simultaneous PROG TIME and FLAME MAIN push to place the unit back in IPI mode This feature can also be activated by the Continuous Pilot On Off switch on the Main Module Child Lock Out The Child Lock out feature can be activated by pressing the PROG Time and UP buttons simultaneously CP will appear on the LCD screen and no signals can be sent from the transmitter To take the control out of Child Lock out mode repeat the above step CP will disapper from the screen Learn Function To program the system to a transmitter press the LEARN button on the Main Module A single audible beep will be heard Press the MODE button on the transmitter to learn the transmitter to the system A series of beeps will be heard Up to two additional NON THERMOSTATIO transmitters can be used simultaneously To learn additional transmitters press and release the learn button again and press the on button on the additional transmitters To clear all transmitters and start over press and hold the LEARN button for 10 seconds A series of three beeps will be heard and the system is clear Low Battery Indicator A low battery icon will appear on LCD screen when transmitter batteries reach low voltage l
44. ge the setting of P2 ON Press and release the SET button Press the UP or DOWN button to change the setting of P2 OFF Press and release the SET button Press the UP or DOWN button to change the setting of the weekend SS P1 ON Press and release the SET button Press the UP or DOWN button to change the setting of P1 OFF Press and release the SET button Press the UP or DOWN button to change the setting of P2 ON Press and release the SET button Press the UP or DOWN button to change the setting of P2 OFF Press and release the SET button The Program Mode has been re programmed Countdown Timer The Countdown Timer Mode allows the control to operate the unit for up to 3 hours in 10 minute increments It can be operated in either the Manual or Thermostat Modes To enter Timer Mode press and release the TIMER button The Timer icon will flash Press the UP or DOWN button to set the running time in 10 minute increments Press and release the SET button The timer will run for the set time duration Pressing the TIMER button while in Timer Mode will terminate the Timer operation The Timer operation will also terminate if the MODE button is cycled to off Thermostat Mode The unit is placed in Thermostat Mode using the MODE button Placing the unit in Thermostat Mode will activate the numbers in the smaller window on the LCD screen Press the UP or DOWN button to change the thermostat set temperature When the desired set temperature app
45. inet arr t pendant tout test de pression de la canalisation de gaz une pression gale ou inf rieure 1 2 Ib po 3 45 kPa The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1 2 psig 3 45 kPa L appareil et son robinet d arr t doit tre d connect e de la canalisation de gaz pendant tout test de pression du syst me des pressions sup rieures 1 2 Ib po 3 45 kPa Install the gas line as follows The appliance shall be installed with a manual shut off ball valve and additional pressure regulator to bring line pressure down to 14 w c Installez la conduite de gaz comme suit L appareil doit tre install avec une vanne manuelle billes et r gulateur de pression suppl mentaire pour faire pression ligne vers le bas 14 wc Page 23 of 60 Upon initial firing check manifold pressure at pressure tap located on the front control panel see Lighting Instructions in section 2 1 NOTE Lors de la premiere v rification de la pression de tir collecteur la pression du robinet situ sur le panneau de commande avant voir les Consignes d allumage la section 2 1 WARNING AVERTISSEMENT DO NOT USE AN OPEN FLAME TO TEST FOR GAS LEAKS NE PAS UTILISER UNE FLAMME DE TEST DE FUITES DE GAZ 3 3 3 THERMOSTAT WALL SWITCH OR DIGITAL ON OFF REMOTE INSTALLATION The burner control knob
46. ing components used in the installation of the fireplace This warranty does not cover any problems caused to installation used venting or vent terminations which are not certified for use with this product Any installation labor construction transportation or other related costs or expenses arising from defective part s repair or replacement or otherwise of same will not be covered by this warranty nor shall Inca Metal Cutting assume responsibility for same Further Inca Metal Cutting will not be responsible for any incidental indirect or consequent damages except as provided by law and in no event shall they exceed the original purchase price In the first year only this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year Inca Metal Cutting may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective parts Page 52 of 60 CONDITIONS AND LIMITATIONS continued Notwithstanding any provisions contained in this warranty Inca Metal Cutting s responsibility under this warranty is defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the o
47. liance and call your service technician or gas supplier I DS 1 Set thermostat to lowest setting 2 Turn on off switch to off Pressure Taps Main Valve Connection Pilot Internal Solenoid Connection Outlet Ports Mounting Holes Flow Control Screw Pilot Connections High Low Connection 0 Inlet Ports Page 13 of 60 2 1 INSTRUCTIONS D ALLUMAGE Pilote intermittent O POUR PLUS DE S CURIT LIRE AVANT D ALLUMER 1 AVERTISSEMENT Quiconque ne respecte pas la letter les instructions dans la pr sente notice risqu de d clencher un incendie ou une explosion entra nant des dommages des blessures ou la mort Cet appareil est quip d un dispositif d allumage qui allume automatiquement le pilote Ne pas tenter d allumer le pilote la main Avant d allumer la veilleuse reniflez tout autour de l appareil pour d celeur une odeur de gaz Reniflez pr s du plancher car certains gaz sont plus lourds que l air et peuvent s accumuler au niveau du sol QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ e Ne pas tenter d allumer d appareil e Ne touchez aucun interrupteur ne pas vous server des telephones se trouvant dans le b timent e Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur e Si vous ne pouvez rejoinder le fournisseur appelez le service des incendies C Ne pousser ou tourner la manet
48. manuel Pour toute assistance ou information suppl mentaire consulter un installateur qualifi un service ou le fournisseur de gaz c US CERT LC773211 EN RAISON DE TEMPERATURES ELEVEES L APPAREIL DOIT ETRE PLACE HORS DE LA CIRCULATION ET LOIN DES MEUBLES ET TENTURES ENFANTS ET ADULTES DOIVENT ETRE AVERTIS DES DANGERS DE LA TEMPERATURE DE SURFACE ELEVEE ET DEVRAIT RESTER A L ECART POUR EVITER LES BRULURES OU L INFLAMMATION DES VETEMENTS LES JEUNES ENFANTS DOIVENT ETRE SOIGNEUSEMENT SURVEILLES QUAND ILS SONT DANS LA MEME PIECE QUE L APPAREIL CLOTHING OR OTHER MATERIAUX COMBUSTIBLES NE DOIVENT PAS ETRE PLACES SUR OU PRES DE L APPAREIL GARDER LA ZONE SALLE CLAIRE ET LIBRE DE MATERIAUX COMBUSTIBLES D ESSENCE ET AUTRES VAPEURS ET LIQUIDES S IL VOUS PLAIT LIRE CE MANUEL AVANT D INSTALLER OU UTILISER CET APPAREIL CONSERVEZ CE MANUEL POUR REFERENCE FUTURE THIS Page 2 of 60 IMPORTANT SAFETY INFORMATION 4 5 1 0 INTRODUCTION nn nc ere 1 1 Specifications Appliance Dimensions amp Installation Codes 6 7 1 2 Features Remote Control Functions iii 8 10 1 3 Intended Use aude dr ante bad ese 11 1 4 General a tees ne tee tente toute ive 11 12 2 0 vOPERATION 2 13 16 2 2 Heat OMPULAGIUSIMEN en Ann ES MS
49. neau de verre de nouveau dans le cadre de la porte Puis suivez les instructions ci dessus pour r installer la porte Page 38 of 60 Do not operate this appliance with the glass front removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person e For use with glass doors certified with the appliance only Do not use any substitute materials e Do not abuse glass doors by striking or slamming shut Ne pas faire fonctionner cet appareil avec la facade en verre est enlev e fissur e ou cass e Remplacement de la vitre doit tre effectu par un technicien sp cialis ou agr e e Pour utilization uniquement avec les portes en verre certifies avec l appareil e Ne pas utiliser de mat riaux de substitution e pas les portes en verre d abus par la suppression ou claquement ferm WARNING AVERTISSEMENT 3 3 7 INITIAL FIRING When lit for the first few times the appliance may emit an odor resulting from evaporation of paint and lubricants used in the manufacturing process Open a door or window for ventilation Anyone with a respiratory condition may need to leave the room during the initial firings It is normal for the appliance to expand and contract while it heats up or cools down whether this is from a cold start or a steady state condition where the fan has come on or off Under these circumstances it is possible that the expansion contraction of the metal parts may produce so
50. ngth measured to center of vent pipe with a 90 degree bend and a 12 305 mm horizontal length measured from center of vent pipe Wall thimble part IMC1082A Horizontal termination cap part IMC1070A or IMC1070B The maximum horizontal vent system consists of 34 10363 mm vertical length with a 4 90 degree bends and a 20 6096 mm horizontal length measured to center of vent pipe Wall thimble part IMC1082A Horizontal termination cap part IMC1070A or IMC1070B Note Horizontal venting shall be supported by means of a steel strap every 3 The maximum vertical system consists of Up to 34 10363mm of vertical length Fire stop Flashing Collar Adapter from flex to Simpson Dura Vent part P574 Termination cap part 0991 A maximum of 4 90 degree bends can be used on the vertical installation with the flex vent The maximum height for this vent configuration is 34 10363 mm and the minimum height is 4 1200 mm the maximum horizontal run is a total of 20 6096mm When fastening the flex vent to the termination and to the unit use a minimum of 3 8 x 5 hex head sheet metal screws on the 4 vent and a minimum of 4 8 x 1 hex head sheet metal screws on the 7 vent Page 28 of 60 VENT TABLE All values are in feet 1 amp 2 1 2 V H2 Max Max 1 21 2 4 3 55 4 Vo 4 7 6 5 8 12 7 Ve 6 10 9 7 11 11 8 11 11 34 11 11 V 34 Feet Max
51. nstall selon les instructions du fabricant ou si des pi ces autres que celles sp cifiquement approuv es avec cet appareil sont utilis es Tout changement ce foyer ou ses contr les peuvent tre dangereux Une mauvaise installation ou l utilisation de cette chemin e peut causer des blessures graves ou la mort par le feu les br lures explosions de chocs lectriques et intoxication au monoxyde de carbone AA WARNING HOT GLASS WILL CAUSE BURNS 00 NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS AVERIEEENENT Une surface vitr e chaude peut causer des br lures Laisser refroidir la surface vitr e avant d y toucher Ne permettez jamais un enfant de toucher la Page 4 of 60 surface vitr e Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Ins
52. on vinyl siding using vinyl siding standoff part IMC1151 To install the termination attach the 4 exhaust to the termination and fasten with 8 x 5 hex head sheet metal screws then attach the 7 vent to the termination and fasten with 4 8 x 2 hex head sheet metal screws be sure that the flex vent overlaps the termination collars a minimum of 2 Then attach the termination to the exterior wall using four wood screws through the holes in the corner of the vent terminal The next step is to apply a bead of mil pac or RTV 106 to top of the 4 exhaust collar on the unit and attach the 4 vent using screws as described above finally apply a bead of mil pac or RTV 106 to top of the 7 vent and attach as described above Safety Cage Cage de s curit Safety cage must be installed on any vent terminating at 7 feet or less Cage de s curit doit tre install sur n importe quel vent se terminant 7 pieds ou moins Page 33 of 60 Vertical Installations Always maintain a 1 clearance around the vent pipe vertical and 1 clearance horizontal when passing through ceilings walls roofs enclosures attic rafter or any combustible surfaces DO NOT PACK AIR SPACES WITH INSULATION NE PAS PACK ESPACES D AIR AVEC ISOLATION When passing through a flat ceiling install a Box Wall thimble Cut a 9 square hole and frame as shown in the diagram below ceiling joists N framing ie 2 din 9 x 9 opening m 1 1 2 long
53. onductor thermostat wire to the unit s lower right hand corner close to the gas supply line Monter le thermostat num rique t l commande marche arr t ou l interrupteur mural l endroit d sir et ex cuter les deux fils du thermostat d orchestre au coin de l appareil en bas droite pr s de la ligne d alimentation en gaz 1 Purchase two conductor thermostat wire which is not provided at any local supplier The gauge of thermostat wire will determine the maximum wire length and distance at which to locate the thermostat digital on off remote or wall switch See Table 1 and the information packaged with thermostat Be aware that as the length of wire increases the probability of adequate operating voltage decreases Achat deux fils du thermostat d orchestre qui n est pas fourni tout fournisseur local La jauge de fil de thermostat de d terminer la longueur de c ble maximale et la distance laquelle de localiser le thermostat num rique interrupteur marche arr t distance ou au mur Voir le Tableau 1 et les informations fournies avec le thermostat Soyez conscient que la longueur du c ble augmente la probabilit de la tension de fonctionnement ad quat diminue Page 24 of 60 TABLE 1 THERMOSTAT WIRE INFORMATION WIRE SIZE MAX WIRE LENGTH AWG mm ft m 22 0 6 10 3 0 20 0 8 25 7 6 18 1 0 40 12 2 16 1 3 64 19 5 14 1 6 100 30 5 After the unit is installed and the gas line
54. ons Pilot will not stay lit after following the lighting 1 instructions continued POSSIBLE CAUSE Improper ignition Poor connections at starter and ignition electrode Broken ceramic cover on ignition electrode Defective piezo igniter Poor grounding of piezo igniter CORRECTIVE ACTION 2 3 4 D A No spark at electrode weak or not heat source for pilot ignition Align the electrode with 1 8 gap to pilot hood Reconnect if loose Replace pilot assembly Replace piezo igniter Tighten mounting nut and or igniter screws B No gas or low gas pressure Gas line shut off s may not be turned on Air in gas lines Gas lines may not be connected Low pressure may be caused by bent line Valve control knob not fully depressed in PILOT position Thermocouple Valve Weak or improperly located pilot flame Defective thermocouple Thermocouple not installed properly Open wire connection in pilot circuit Defective Valve B Defective safety circuit Loose or defective connections 1 2 3 4 Turn on shut off valves Purge gas lines Connect all gas lines Check for a kinked line Fully depress control knob Adjust and clean pilot The flame must impinge on or engulf the thermocouple Replace thermocouple Make sure all wire connections at the gas valve terminals are tight and the thermocouple is fully inserted into the mounting bracket Check wire continui
55. oor WHAT TO DO IF YOU SMELL GAS e Do nottry to light any appliance Do not touch any electric switch do not use any phone in your building e Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions e f you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 1 STOP Read the safety information above on this label 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Do not attempt to light the pilot by hand 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 6 Turn on all electric power to the appliance 7 Set thermostat to desired setting or switch to ON if not using a thermostat 8 If the appliance will not operate follow the instructions To Turn Off Gas To App
56. outes les fen tres Il est recommand que vous br lez votre foyer pendant au moins 4 quatre heures la premi re fois que vous l utilisez Hot while in operation Do Not Touch Severe burns may result Keep children clothing furniture gasoline and other liquids having flammable vapors away Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean L appareil est chaud lorsqu il fonctionne Ne pas toucher l appareil Risque de br lures graves Surveiller les enfants Garder les v tements les meubles l essence ou autres liquides produisant des vapeur inflammables loin de l appareil Les tout petits les jeunes enfants et d autres peuvent tre sensibles a
57. parts against tarnishing Electrical 110 volt and millivolt components and wearable parts such as blowers gas valves thermal switches switches wiring remote controls igniters gaskets glass thermal damage only and pilot assemblies are covered for 1 year and Inca Metal Cutting will provide replacement parts free of charge during the first year of the limited warranty CONDITIONS AND LIMITATIONS Inca Metal Cutting warrants its products against manufacturing defects to the original purchaser only i e the individual or legal entity registered customer whose name appears on the original invoice provided that the purchase was made through an authorized Inca Metal Cutting dealer and is subject to the following conditions and limitations This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives A licensed authorized service technician or contractor must have installed the gas fireplace Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect Parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discoloring caused by excessive heat abrasives chemical cleaners nor any vent
58. prong receptacle Do not cut or remove the grounding prong from this plug AVERTISSEMENT Instructions la terre lectrique Cet appareil est quip d un trois broches terre pour votre protection contre les risques de choc lectrique et doit tre branch directement dans une prise trois broches r cipient Ne pas couper ou retirer la broche de terre de cette fiche WARNING Fire or explosion hazard Can cause property damage severe injury or death This is a fast acting thermocouple Replace it only with another fast acting thermocouple specified by the appliance manufacturer Refer to manual for the replacement part number AVERTISSEMENT Risque d incendie ou d explosion Peut entrainer des dommages mat riels des blessures graves ou la mort Ceci est un thermocouple rapide Peut tre remplac uniquement par un autre thermocouple rapide sp cifi par le fabricant de l appareil Veuillez consulter la notice pour le num ro de pi ce Page 56 of 60 APPENDIX AMERICAN FLAME VALVE INFORMATION spark to pilot assembly connection to module orange wire pilot adjustment screw S connection to module white wire inlet pressure tap main valve internal sole oid connection green amp white wires pilot orifice access pilot internal solenoid connection orange amp natural to propane white Wires i sion shaft under rubber cap outlet pressure tap Page 57 of 60 APPEN
59. que de la salle et l cart des surfaces chaudes Tout cran ou grille de protection pour l entretien d un appareil doit tre remplac avant de faire fonctionner l appareil Installation et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au moins annuellement par un technicien qualifi Un nettoyage plus fr quent peut tre n cessaire en raison de peluches provenant des tapis literie etc Il est imp ratif que les compartiments de contr le les br leurs et les conduits d air de l appareil soient gard s Ce foyer est un produit ventil Ce foyer doit tre correctement install par un technicien qualifi La porte en verre doivent tre plac s correctement et scell Si cet appareil n est pas correctement install par un technicien qualifi avec la porte en verre bien en place et des fuites de gaz scell s peuvent se produire Attention Au moment de l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entrainer un fonctionnement inad quate et dangereux Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin Page 5 of 60 1 0 INTRODUCTION 1 1 SPECIFICATIONS TABLE 1 ITEM NATURAL GAS NG INPUT Hi 21 000 Btu hr 6 15 kW INPUT Lo 13 000 Btu hr 3 81 kW MANIFOLD PRESSURE Hi COLLECTEUR DE PRESS
60. r Utilisez uniquement graver moyen fourni avec cet appareil z T Og Step 1 Sprinkle burner channel with glass Make sure to cover the burner pan evenly Then add decorative rocks to outer pan area Saupoudrer le canal du br leur avec verre Assurez vous de couvrir la casserole du br leur de facon gale Puis ajoutez les roches d coratives la zone pan ext rieur Picture shows optional rock amp glass kit This shows positions of media critical to correct flame pattern h Step 2 Make sure that only the glass covers the burner holes Assurez vous que seul le verre recouvre les trous du br leur G Install the door see instructions below Replace lower access strip in front of door Installez la porte voir les instructions ci dessous Remplacer la bande inf rieure d acc s en face de la porte Turn your fireplace on and wait approximately 10 15 minutes until the flames are a nice yellow colour Note the flame pattern and in any low or high areas adjust the amount of river glass to correct gas flow WARNING AVERTISSEMENT YOU MUST WEAR FLAME AND HEAT RESISTANT GLOVES FOR THESE ADJUSTMENTS VOUS PORTER DES GANTS DE FLAMME ET RESISTANT A LA CHALEUR DE CES AJUSTEMENTS Page 37 of 60 3 3 6 Door Installation Fit the top of the door onto the top door brackets make sure the door is centered on the appliance Push the bottom of the door into the appliance and pull the 2
61. r appliances gt 10 000 Btuh 3 kW and lt 100 000 Btuh 30 kW 36 in 91 cm for appliances gt 100 000 Btuh 30 kW 6 in 15 cm for appliances 10 000 Btuh 3 kW 9 in 23 cm for appliances gt 10 000 Btuh 3 kW and lt 50 000 Btuh 15 kW 12 in 30 cm for appliances 50 000 Btuh 15 kW C Clearance to permanently closed window D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 61 cm from the center line of the terminal 18 1 2 18 1 2 E Clearance to unventilated soffit F Clearance to outside corner 0 0 3 3 H Clearance to each side of center line 3 ft 91 cm within a height 15 ft 4 5 m extended above meter regulator above the meter regulator assembly assembly d G Clearance to inside corner Clearance to service regulator vent 3 91 outlet J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in 15cm for appliances 10 000 Btuh 3kW 12 in 30 cm for appliances 210 000 Btuh 3kW and 100 000 Btuh 30kW 36 in 91 cm for appliances 2100 000 Btuh 30kW 6 in 15cm for appliances 10 000 Btuh 3kW 9 in 23 cm for appliances 210 000 Btuh 3kW0 and 550 000 Btuh 15kW 12 in 30cm for appliances 250 000 Btuh 15kW0 K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10ft
62. ra pas responsable des dommages accessoires indirects ou cons quents sauf dans les cas pr vus par la loi et en aucun cas ils d passent le prix d achat original Dans la premi re ann e seulement cette garantie s tend la r paration ou le remplacement des pi ces garanties qui sont des d fauts de mat riaux ou de fabrication condition que le produit ait t utilis conform ment aux instructions de fonctionnement et dans des conditions normales Apr s la premi re ann e Inca de coupe en m tal peut sa discr tion se d charger de toutes obligations l gard de cette garantie en remboursant l acheteur d origine le prix de gros de toute pi ce garantie qui est d fectueuse s Nonobstant toutes dispositions contenues dans la pr sente garantie Inca Metal Cutting responsabilit en vertu de cette garantie est d finie comme ci dessus et il ne doit en aucun cas s tendre des dommages indirects accessoires ou indirects Cette garantie d finit les obligations et la responsabilit de Metal Cutting l gard de l Inca Metal Cutting foyer au gaz et toute autre garantie expresse ou implicite l gard de ce produit ses composants ou accessoires est exclue Inca Metal Cutting n assume ni n autorise aucun tiers assumer en son nom toute autre responsabilit l gard de la vente de ce produit Inca Metal Cutting ne sera pas responsable d une surchauffe des refoulements des d versements caus s p
63. rantie du fabricant n est pas transf rable et ne peut tre prolong que ce soit par l un de nos repr sentants Une licence un technicien de service autoris ou l entrepreneur doit avoir install le foyer gaz Installation Page 53 of 60 CONDITIONS ET LIMITES SUITE doit tre faite en conformit avec les instructions d installation incluses avec le produit et toutes les capacit s locales et nationales et de pr vention des incend Cette garantie limit e ne couvre pas les dommages caus s par une mauvaise utilisation manque d entretien accident des alt rations des abus ou de n gligence Installation de pi ces provenant d autres fabricants annulera cette garantie Cette garantie limit e ne couvre pas non plus les gratignures les bosselures la corrosion ou la d coloration caus s par la chaleur excessive les abrasifs de nettoyants chimiques ou tout composant de ventilation utilis dans l installation de la chemin e Cette garantie ne couvre pas les probl mes caus s l installation d a ration ou de ventilation utilis licenciements qui ne sont pas homologu s pour une utilisation avec ce produit Toute installation le travail la construction le transport ou autres frais connexes ou frais d coulant de la pi ce d fectueuse s la r paration ou le remplacement ou non de m me ne seront pas couverts par cette garantie ni Inca Metal Cutting assumer la responsabilit de m me En outre Inca Metal Cutting ne se
64. ress the UP or Down button to set minutes Press SET to advance to AM or PM Press the UP or Down button to set AM or PM Press the SET button to advance to the day of week Use UP or Down button to select the day of the week The control will exit setup mode in 20 seconds MODE Button The MODE button cycles the unit through the basic operational modes When off press and release the MODE button to turn the unit on in Manual mode Press and release the MODE button again and the unit will operate in the Thermostat mode Press and release the MODE button again and the unit will turn off Page 8 of 60 Program Mode The Program function is controlled by the PROG TIME button The control may be programmed for up to two settings for weekdays and two settings for weekends The control is preset to factory settings When the Program Mode is activated the unit will automatically be operating in the Thermostat Mode The unit will turn on or off based upon room and set temperature To activate the Program mode press and release the PROG TIME button To change the settings for the Program mode press and hold the PROG TIME button for 5 seconds The program feature will flash at the top of the screen Press the UP or DOWN button to change the setting of the weekday MTWTF P1 ON Press and release the SET button Press the UP or DOWN button to change the setting of P1 OFF Press and release the SET button Press the UP or DOWN button to chan
65. smantled use the vent manufacturer s instructions and the sealing instructions for reassembly Si tout moment de la tuyauterie d admission d air de ventilation est d mont e utilisez la ventilation instructions du fabricant et les instructions d tanch it pour le remontage NOTE Figure 5 This appliance s venting system is room sealed or Direct Vent This means that it does not require room air for combustion but draws air from outside the building USE OF COUPLERS WITH FLEX PIPE In the event of a puncture of the vent pipe or if an extension is needed couplers may be used High temperature sealant shall be applied to the ends of the coupler and the coupler shall then be inserted into the flex vent Use 8 x 7 hex head sheet metal screws on each end of the joint to fasten the coupler to the venting Page 26 of 60 Figure 6 Attach with sheetmetal screws 3 places on each A flex section around diameter NN QUAM i j EE WU VME Apply or RIV 106 Sealant here both ends Dura Vent The minimum vent system for horizontal termination must consist of Dura Vent adapter Part 0924N3 directly on top of unit 12 305mm vertical length of vent 90 degree elbow 12 305 mm length horizontally Wall thimble part IMC1082A Horizontal termination cap 0984 The maximum horizontal vent system consists of Dura Vent adapter Part 0924N3 directly on top of unit 34 10363 mm verti
66. t 6AL Pilot Assembly Standing pilot PSE NA257 Orifice MP0505 Gas Valve Robertshaw 9A0A68A6A Piezo Igniter R S only 1244 46 Intermittent Pilot amp Remote Control Valve Parts Description Pilot Assembly Intermittent Valve Valve with step motor installed Remote Step Motor for AF 4000 Valve Supreme Control Module incl wire harness Plug in Adapter 7 5V A C amp 24 wires Battery Back up Extension Module for 120V operation Supreme Handheld transmitter Part PSE NA291 AF 40004 AF 4044 AF 4000MOT AF 4000MOD S01 AF 4000ADP24 AF 4000BBU AF 4000120MODS01 AF 4000HHS01 Page 51 of 60 7 0 INCA METAL CUTTING S WARRANTY PROTECTION FOR ALL METAL CUTTING GAS FIREPLACE PRODUCTS Inca Metal Cutting s products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work The burner and valve assembly are leak tested and test fired at a quality control test station Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you the customer receives the quality product that you expect from Inca Metal Cutting s INCA METAL CUTTING S GAS FIREPLACE S WARRANTY Your Inca Metal Cutting gas fireplace is guaranteed to be free of defects in materials and workmanship for a period of 5 years from the date of purchase This covers combustion chambers heat exchangers and burners as well as stainless steel
67. tallation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean This fireplace is a vented product This fireplace must be properly installed by a qualified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with the glass door properly seated and sealed gas leakage can occur Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation AVERTISSEMENT Ne pas utiliser cet appareil s il a t plong meme partiellement dans l eau Appeler un technician qualifi pour inspecter l appareil et remplacer toute partie du syst me de commande et toute commande qui a t plong e dans l eau Les tout petits les jeunes enfants et d autres peuvent tre sensibles aux br lures par contact accidentel Une barri re physique est recommand s il ya des personnes risque dans la maison Pour restreindre l acc s une chemin e ou un po le installer une barri re de s curit r glable pour garder les tout petits les jeunes enfants et les personnes ris
68. tallation n est pas couvert par la garantie d usine 3 3 10 ALTITUDE ADJUSTMENT Altitude Natural Gas Orifice Size 0 4 500 ft 0 1372 m 43 4 500 6 500 ft 1372 1981 m 44 6 500 8 000 ft 1981 2438 m 45 All valves have been pre set and certified for installation at elevations from 0 4500 feet 1 1372m above sea level When installing this unit at higher elevations it is necessary to decrease the input rating by replacing the existing burner orifice with a smaller size for installations over 4500 feet 1372m The appliances input should be reduced 496 for each additional 1000 feet 305m above sea level For the USA de rate the unit from sea level according to the gas installation code Toutes les vannes ont t pr programm es et certifi pour l installation une altitude de 0 4000 pieds 1 1220m d altitude Lors de l installation de cet appareil haute altitude il est n cessaire de baisser la note d entr e par le remplacement de l orifice du br leur existant avec une taille plus petite pour les installations de plus de 4500 pieds 1372m L entr e des appareils devrait tre r duite de 4 pour chaque 1000 pieds suppl mentaires 305m au dessus du niveau des mers Pour les Etats Unis de taux de l unit de niveau de la mer selon le code d installation de gaz 3 3 11 FAN ACCESSIBILITY FAN ACCESSIBILIT TURN THE MAIN GAS amp POWER OFF TO FIREPLACE BEFORE COM
69. te d admission do gaz qu la main Ne jamais employer d outil cette fin Si la manette reste coinc e ne tentez Pas de la r parer appelez un technician qualifi Quiconque tente de forcer la manette ou de la r parer peut provoquer une explosion ou un incendie D N utilisez pas cet appareil s il a t plunge dans l eau meme partiellement Faites inspecter l appareil par un technician qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau EN asuscnossvanswecc ARR TEZ Lisez les instructions de s curit sur la portion sup rieure de cette etiquette R glez le thermostat la temperature la plus basse Coupez l alimentation lectrique de l appareil Ne tentez pas d allumer le pilote la main Attendre cinq 5 minutes pour laisser chapper tout le gaz Reniflez tout autour de l appareil y compris pr s du plancher pour d celer une odeur de gaz Si vous sentez une odeur de gaz ARRETEZ Passez l tape B des instructions de s curit sur la portion sup rieure gauche de cette etiquette Sil ny a pas d odeur de gaz passez l tape suivante Mettez l appareil sous tension R glez le thermostat la temperature d sir e Si l appareil ne fonctionne pas suivez les instructions Pour couper le gaz l appareil et appelez votre technicien ou votre fournisseur de gaz L APPAREIL 1 R glez le thermostat la temperature la plus basse 2 Activ
70. tibles doit tre maintenu autour du tuyau de 1 sur toutes les canalisations horizontales et verticales fonctionne NOTE FIGURE 7 Apply RTV high temperature sealant around male pipe VENT RESTRICTOR INSTALLATION Vent Configuration Restrictor Size 60 40 VENT RESTRICTOR 50 To fasten the Restrictor Plate to the ceiling of the firebox 1 Remove the 2 screws that are in place 2 Align holes in the Restrictor that match the required degree of restriction 3 Fasten Restrictor Plate back in place SCREW HERE DETAIL CALET 4 Page 31 of 60 VENT RESTRICTOR INSTALLATION continued The restrictors are installed by removing the 2 screws on the ceiling of the firebox place the desired restrictor in place and use the screws to fasten the restrictor to the firebox You must first remove the firebox baffle 4 screws before installing the desired restrictor Return the firebox baffle after installing the restrictor Typical Dura Vent amp Security Chimney s Installation Vent terminals shall not be recessed into a wall or siding Vertical High Wind Termination RSS T Roof SS Wall thimble SC Firestop Vcr 5 CAE Ridgid to Flex Decorative Wall Adaptor Cover 9 Decorative Wall Vent Section cover Horizontal Vent Vent Section X Termination t Vent Section eS Wall thimble Vent Section 5 Elbow 7 Firestop ES e _ Vent SECO Vent RM
71. ty and connections in the pilot circuit Connect the millivolt meter probes to the thermopile terminals on the gas valve Turn the valve to the PILOT position depress and light If the meter reading is greater than 540 millivolts after 30 seconds the thermopile is good If the pilot does not stay lie the valve is defective Check section B below before replacing valve Check continuity tighten wiring or connections and repair Page 47 of 60 Main burner will not light A Valve Switches 1 Valve control off 1 Turn to ON position 2 Blockage at the burner line 2 Check and clean orifice or ports 3 Defective wall switch 3 Conducta continuity test or jumper wire thermostat test and replace if defective 4 Defective wiring or 4 Conducta test with a jumper wire and connections repair as required 5 Excessive length of thermostat 5 Reduce wire length to less than 100 feet wire from valve to wall switch or increase wire size or thermostat 6 Wall switch thermostat 6 Wire correctly incorrectly wired 7 Defective Valve 7 Turn valve and ON OFF switch to the ON position Check with millivolt meter at terminals TP TH Millivolt meter should read greater then 540 millivolts If the reading is OK and the burner does not come on replace the gas valve 8 Thermopile may not be 8 Recheck using the millivolt meter The generating sufficient voltage pilot flame may not be high enough for 750 mV the
72. ualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water STOP Read the safety information above on this label Set the thermostat to the lowest setting Turn off all electric power to the appliance Controls are accessed by opening the bottom louver Push in gas control knob slightly and turn clockwise to U OFF Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step Turn control knob counterclockwise O pilot position Depress control knob and push in piezo igniter button Once pilot ignites continue to hold the control knob in for one 1 minute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 4 7 knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several attempts turn the gas control knob to OFF and call your service technician or gas supplier Turn gas control knob counterclockwise O to ON Turn on all electric power to the appliance Set thermostat to desired setting or turn appliance switch to ON position then close bottom louver 1 Set thermostat to lowest setting 2 Turn off all electric power to the appliance if servic
73. unds Il est normal que appareil dilater et se contracter pendant qu elle se r chauffe ou se refroidit s il s agit d un d marrage froid ou d un tat d quilibre o le ventilateur est venu sous ou hors tension Dans ces circonstances il est possible que l expansion et la contraction des pi ces m talliques peuvent produire des sons Occasionally after a cold start vapor may condense and fog the glass and the flames may be partially blue After a few minutes the moisture will disappear and the flames will become yellow Visually check the flame after warm up 3 8 TO 1 2 CORRECT FLAME 10mm TO 13mm ae INCORRECT FLAME E e f j THERMOPILE THERMOCOUPLE THERWOPILE THERMOCOUPLE 3 3 8 MANIFOLD PRESSURE REGULATOR ADJUSTMENT The manifold pressure regulator controls gas input and flame height and is pre adjusted at the factory No further adjustment is required Page 39 of 60 PILOT FLAME ADJUSTMENT For proper operation the pilot and main burner flames must be steady and not lifting off or floating The top 3 8 1 2 10 13mm of the thermocouple should be engulfed by the pilot flame 3 3 9 PRIMARY AIR ADJUSTMENT AJUSTEMENT DE L AIR PRIMAIRE Aeration is factory set but may need adjustment for altitude or movement during shipping L a ration est r gl e en usine mais peut n cessiter un ajustement de l altitud
74. ur travail Le br leur et la valve sont des essais d tanch it et d essai ont tir sur un poste de contr le de qualit Une fois assembl chaque foyer est soigneusement inspect par un technicien qualifi avant l emballage afin de s assurer que vous le client recoit le produit de qualit que vous attendez d Inca Metal Cutting FOYER AU GAZ DE COUPE METAL INCA S GARANTIE Votre foyer au gaz Inca Metal de coupe est garanti d tre exempt de d fauts de mat riaux et de fabrication pour une p riode de 5 ans compter de la date d achat Cette garantie couvre chambres de combustion changeurs de chaleur et br leurs ainsi que des pi ces en acier inoxydable contre le ternissement Electrique 110 volts et millivolt et les pi ces d usure comme les souffleuses les vannes de gaz capteurs thermiques interrupteurs c blages t l commandes allumeurs les joints le verre dommage thermique seulement et les assembl es pilotes sont couverts pendant 1 an et Inca Metal Cutting fournira de remplacement les pi ces gratuitement durant la premi re ann e de la garantie limit e Inca Metal Cutting garanti ses produits contre les d fauts de fabrication l acheteur d origine seulement la personne physique ou morale client inscrit dont le nom figure sur la facture d origine condition que l achat a t effectu aupr s d un revendeur autoris Inca Metal Cutting et est soumis les conditions et limitations suivantes Cette ga
75. ux br lures par contact accidentel Une barri re physique est recommand s il ya des personnes risque dans la maison Pour restreindre l acc s a une chemin e ou un po le installer une barri re de s curit r glable pour garder les tout petits les jeunes enfants et les personnes risque de la salle et l cart des surfaces chaudes Tout cran ou grille de protection pour l entretien d un appareil doit tre remplac avant de faire fonctionner l appareil Installation et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au moins annuellement par un technicien qualifi Un nettoyage plus fr quent peut tre n cessaire en raison de peluches provenant des tapis literie etc Il est imp ratif que les compartiments de contr le les br leurs et les conduits d air de l appareil soient gard s propres Page 12 of 60 2 0 OPERATION 2 1 LIGHTING INSTRUCTIONS for Intermittent Pilot FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the fl
76. votre fournisseur de gaz appelez les pompiers C Utilisez seulement votre main pour enfoncer ou tourner le bouton de contr le du gaz Ne jamais utiliser d outils Si le bouton ne sera pas enfoncer ou tourner la main ne pas essayer de le r parer appelez un technicien qualifi R paration de la force ou la tentative peut entrainer un incendie ou une explosion D Ne pas utiliser cet appareil si une partie a t sous l eau Appelez imm diatement un technicien qualifi pour inspecter l appareil et remplacer toute partie du syst me de contr le et toute commande de gaz qui a t sous l eau STOP Lire les consignes de s curit ci dessus sur cette tiquette R glez le thermostat r glage le plus bas Coupez l alimentation lectrique de l appareil Les contr les sont accessibles par l ouverture de la persienne inf rieure Poussez le bouton de contr le du gaz et tourner vers la droite pour OFF Attendez cing 5 minutes pour laisser chapper tout le gaz Puis une odeur de gaz y compris pr s du plancher Si vous sentez une odeur de gaz ARRETEZ Suivez B des consignes de s curit ci dessus sur cette tiquette Si vous ne sentez pas de gaz passez l tape suivante Tourner le bouton de commande antihoraire O poste de pilote Enfoncez le bouton de commande et de pousser dans pi zo allumeur bouton Une fois pilote s enflamme continuent tenir le bouton de commande pour un 1 minute apr s que le pilote est allum
77. water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Ne pas se servir de cet appareil s il a t plong dans l eau m me partiellement Faire inspecter l appareil par un technicien qualifi et remplacer toute partie du syst me de contr le et toute commande qui ont t plong es dans l eau Page 11 of 60 IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and or contraction noises during the start up or cool down cycle It is not unusual for gas fireplaces to give off some odors the first time they are burned This is due to the oils and sealants in the manufacturing process PLEASE ENSURE YOU ROOM IS WELL VENTILATED DURING BURN OFF OPEN ALL WINDOWS It is recommended that you burn your fireplace for at least 4 four hours the first time you use it IMPORTANT S IL VOUS PLAIT LIRE ATTENTIVEMENT CE QUI SUIT Il est normal pour les foyers fabriqu s d acier d gager une certaine expansion et ou des bruits de contraction pendant le d marrage ou cycle de refroidissement Il n est pas inhabituel pour les foyers gaz de d gager certaines odeurs la premi re fois qu ils sont br l s Cela est d aux huiles et produits d tanch it dans le processus de fabrication S IL VOUS PLA T VOUS ASSURER pi ce est bien a r e pendant BR LER Ouvrir t
78. x 34 5 high x 15 5 deep 2 000 2 000 15 500 6 000 p MINIMUM CLEARANCES TO COMBUSTIBLES A z 48 TO INTERNAL CEILING 2 TO INTERNAL SIDE COMBUSTIBLES 15 5 TO BACK WALL FROM FRONT OF UNIT D 6 TO SIDE WALL 33 5 FROM FLOOR TO COMBUSTIBLE MATERIAL F 36 MINIMUM CEILING HEIGHT FROM TOP OF UNIT G 40 MINIMUM FROM FLOOR TO MANTLE SEE DIAGRAM NEXT PAGE H 0 BASE OF UNIT TO FLOOR Page 20 of 60 allowable mantel area 40 000 min distance from floor 12 000 distance at min height Clearances are in accordance with local installation codes and the requirements of the gas supplier The mantel placement chart on this page illustrates the allowable mantel sizes and placements The 45 degree angle can be used to determine the allowable mantel size based on the elevation above the units upper trim Les d gagements sont en conformit avec les codes d installation locaux et les exigences du fournisseur de gaz Le tableau placement manteau sur cette page illustre les dimensions et les emplacements admissibles chemin e L angle de 45 degr s peut tre utilis pour d terminer la taille permise manteau repose sur l l vation au dessus de la garniture unit s sup rieures When using paint or lacquer to finish the mantel such paint or lacquer must be heat resistant up to 250 F to prevent discolorations Lors de l utilisation de peinture ou de
79. y Annual service An annual service call should take between 1 2 hours Start by disassembling the unit take off the door and remove all the embers burner and logs Clean fan with a vacuum to remove any dust Vacuum the whole firebox and all the air passages Clean the burner After everything is clean check all the connections and the chassis ground and reassemble Clean the glass 4 3 GLASS CLEANING The inside of the glass may require periodic cleaning to remove deposits left from impurities in the gas and combustion air For best results use a ceramic glass cleaner or polish Use a cleaner suitable for ceramic glass e g cerama bryte stove cleaner Avoid the use of ammonia based cleaners such as Windex Do not clean while hot Do not use abrasive cleaners Make sure you clean off any white film on the fireplace glass as soon as possible otherwise the glass may deteriorate 4 4 BURNER amp PILOT CLEANING Periodic cleaning is necessary for proper operation Remove the burner and check that the burner orifice is clean Visually inspect the pilot Brush or blow away any dust lint or foreign debris If the pilot orifice is plugged disassembly may be required to remove any foreign material from the orifice or tubing When the appliance is back in service check the pilot flame pattern For re lighting refer to the lighting instructions in Section 2 1 Page 45 of 60 4 5 VALVE AND PILOT ASSEMBLY REPLACEMENT WARNING A

Download Pdf Manuals

image

Related Search

Related Contents

Istruzioni di montaggio  トリニトロンカラーテレビ 取扱説明書  European Guarantee  Untitled - Kilpiset  User Manual - IMS B001 evaluation board  News du Salon Planète Mode - Lycée Rosa Parks de Montgeron  tecra a6 - Wiki Karat  Bartscher PRO Plus 40T Bartscher PRO Plus 60T Bartscher PRO  KUDA 045150 holder  Anti-Alias Multichannel Module  