Home

INSTALLATION MANUAL MANUEL D`INSTALLATION

image

Contents

1. p2 Bouton int rieur de sortie rdais2 Contacthorloge SSCS ctavierfirmarron SSCS ae Clavier vert ou bleu clairage D 693 Electronique d port e R1 Ci T1 R2 C2 T2 R3 C3 T3 P1 M P2 mm n H i 1 G che rupture Ouvert Contact au repos Gache mission v Varistance H Ferm GALEO en fonction Bouton Poussoir Commande par bouton poussoir Le raccordement du bouton poussoir P1 est pr vu pour commander le relais 1 Le raccordement du bouton poussoir P2 est pr vu pour commander le relais 2 Le mode et la temporisation sont programmables Le contact horloge H permet l utilisa tion de toutes les touches comme bou ton ext rieur Si le contact horloge est ouvert les touches sont utilis es comme des termes habituels Si le contact horloge est ferm toutes les touches sont utilis es pour l ouverture libre GALEO en fonction clavier cod LE LEE OU Oooo m cdvi com cdvigroup com Temporisation clairage clavier 10 99 sec 00 continue 10 D faut 1 bip OK 4 bips Erreur cdvi com OI SE SOC Temporisation relais 1 01 99 sec 00 continue 01 D faut 1 bip OK 4 bips Erreur cdvigroup com Tapez 2 fois le code Maitre Temporisation relais 2 01 99 sec 00 continue 01 D faut 1 bip OK 4 bips Erreur GALEO3R Temporisation relais 3
2. 01 99 sec 00 continue 01 D faut 1 bip OK 4 bips Erreur Nombre de termes 4 ou 5 05 D faut 1 bip OK 4 Erreur Code maitre Tous les boutons sont valides 12345 D faut 1 bip OK 4 bips Erreur MANUEL D INSTALLATION GALEO Clavier cod r tro clair lectronique d port e Termes de Termes de Termes de modification modification modification relais 1 relais 2 relais 3 Signal Programmation sonore des codes 00 99 4 ou 5 chiffres 2 2 2 Supprimer chiffres chiffres chiffres les bips Rang occup AB d faut i3 d faut 46 d faut 1 Autoriser 1 les bips Rang libre 1 bip OK 1 bip OK 1 bip OK 1 bip OK 4 bips Erreur 4 bips Erreur 4 bips Erreur 4 bips Erreur B cdvi com cdvigroup com 7 LES VALEURS DU GALEO SONT PAR DEFAUT Sans codes Temporisation clairage 10 s Temporisation d ouverture pour tous les relais 1 secondes Nombre de termes 5 Code maitre usine 1 23 4 5 Temporisation s curit programmation 120 secondes Termes de modification par utilisateur a Version 1 relais Groupe 1 A et B a Version 2 relais Groupe 2 a Version 3 relais Groupe 3 4 et 6 SIGNAUX SONORES 1 bip court Mise sous tension 1 bip long Validation d une saisie en programmation ou ouverture autoris e 2 bips courts Entr e ou sortie de progra
3. est 1 23 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez le n du rang programmer en fonction du nombre de relais de votre GALEO Si le rang est libre tapez les 4 ou 5 termes du code Si le rang est occup 4 bips sont mis Tapez les 4 ou 5 termes du code ou tapez O O O O ou pour annuler le code enregistr Un bip sonore est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement Si le code compos correspond un code existant ou s il est identique au code ma tre 4 bips sonores indiquent une erreur Les codes 00000 et 0000 servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte E PROGRAMMATION DES TEMPORISATIONS 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 123 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez AO pour la temporisation du clavier Un bip sonore est mis Tapez la dur e de commande en secondes Ex De 10 pour 10 secondes 99 pour 99 secondes ou tapez 00 pour obtenir un clairage permanent Un bip sonore de validation est mis 3 Relais 1 Groupe 1 Tapez A1 Relais 2 Groupe 2 Tapez A2 Relais 3 Groupe 3 Tapez A3 Cette manipulation vous permet de g rer la temporisation des relais Vous
4. plate by using the supplied M4x10 Torx screw and T20 Trox spanner hardware Place the screw cap at the bottom of the keypad cdvi com 14 cdvigroup com M4x19 Torx screw T20 Spanner Insert the 2 plastic anchors in the holes Place the back plate of the GALEO and screw on the wall using the supplied M4x30 mounting screws Insertthe 2 plastic anchors in the holes Place the bracket of the electronic and screw the wall using the supplied M4x30 screws Slide the box from up to down on the bracket M4x30 mounting screws Mounting plate for remote elec tronic box Plastic an chors Wiring sealed cap AIAG SE SOC Insert the cable in the hole access area of the back plate Then mount the keypad on the back plate placing first the top in the hooks and then the bottom Insert the cable in the remote electronic and wire the cable to the terminals Don not forget to install the varistor on the lock Refer to page 2 Notes and Recommendations INSTALLATION MANUEL GALEO Illuminated Weatherproof Keypad with remote electronics 5 WIRING DIAGRAM GALEO 2 RELAY OUTPUTS D 693 Remote electronics n P3 jumper allows jl to the user to modify its own Pin code gt To enable this feature put i po the jumper on mE E see Programming section in the instruction manual Bj TO OU Oooo P
5. 230 V AC Cables pr conis s entre le GALEO et l lectronique d port e Pour une extension du cable 3 m tres fourni privil giez un cable 2 paires 4 fils SYT1 8 10 me AWG 20 Alimentations pr conis es ARD12 et BS60 Montage Afin d optimiser la fixation du GALEO et de pr venir les cdvi com 2 cdvigroup com 33 Test vibrations DEEE 110 Test brouillard salin 1064 Certification 25 70 C ELECTRONIQUE D PORT E C Certification CE TE IP52 20 C 70 C E DEEE t tentatives d arrachage privil giez les surfaces planes Composition des codes Par soucis de s curit veillez modifier le code maitre usine par celui de votre choix Lors du changement du code usine et de la cr ation des codes utilisateurs vitez les codes trop simples ex les suites 3 4 5 6 7 Recommandations d installation Pour s curiser l installation n oubliez pas de placer la varistance sur le syst me de verrouillage en parall le au niveau de l alimentation L lectro nique d port e du GALEO doit tre imp rativement install e dans un environnement clos et prot g e des conditions climatiques ext rieures Tension libre MANUEL D INSTALLATION GALEO Clavier cod r tro clair lectronique d port e 3 L MENTS FOURNIS GALEO Electronique d port e 4 MONTAGE V
6. devez r aliser la d marche pour chacun des relais de votre GALEO Un bip sonore est mis Tapez la dur e de commande en secondes cdvi com cdvigroup com 9 Ex De 01 pour 1 seconde 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais Un bip sonore de validation est mis 4 Pour sortir de la programmation tapez B Deux bips sonores sont mis pour confirmer le retour au mode normal de fonctionnement 4 bips indiquent une erreur de saisie F REMISE A ZERO DU CODE MAITRE En fonctionnement normal positionnez un cavalier en P2 Attendre 1 seconde et enlevez le cavalier Un bip est mis Le code est de nouveau 12345enb5termesou1234 en 4 termes G CHANGEMENT DU CODE D ENTREE PAR L UTILISATEUR L autorisation de changement de code par l utilisateur est d termin e par le positionnement du cavalier P3 Otez le cavalier pour interdire le changement de code et placez le cavalier pour autoriser le changement 1 Composez le code utilis actuellement Le relais d ouverture est command Un bip sonore est mis 2 Tapez imm diatement les 2 termes du code de modification Relais 1 la premi re utilisation A et B Relais 2 la premi re utilisation 1 et 3 Relais 3 la premi re utilisation 4 et 6 Un bip sonore est mis pour autoriser le changement 3 Composez le nouveau code d ouverture Deux bips sonores confirment la validation du nouveau code e
7. emitted enter the 4 or 5 digit User code 3 To Change a User code enter the user location 4 beeps are emitted to indicate that user location is already programmed Enter a new 4 or 5 digit code A beep is emitted to confirm the new user code 4 To delete a User code enter the user location 4 beeps are emitted Press O O O O O in 5 digit length code or O O O O in 4 digit length code A beep is emitted to confirm the new user code NOTE If the Pin code is already programmed or is identical to the master code then 4 beeps are emitted Press B to exit from the programming mode 2 beeps are emitted to confirm that the keypad is in stand by operating mode E TIME OUTPUTS This section allows to program the illumina tion time and the Relay activation time 1 Enter the master code twice 12345 cdvi com 18 cdvigroup com default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press AO to program the key in keypad time and the keys lit time 1 beep is emitted Enter the time in 10th of second 10 for 10 seconds up to 99 for 99 seconds the backlighting dims 10 seconds after the last keypress or switches off after ente ring a valid code Press 00 for permanent illumina tion keys One beep is emitted to validate the time 3 Press A1 to program relay 1 output time door release time 1 beep is emitted For a latched output enter the time in seconds 01 for 1 second up to 99 fo
8. location 59 to activate relay 1 Group 2 from user location 60 to user location 79 to activate relay 2 Group 3 from user location 80 to user location 99 to activate relay 3 Release time for relay 3 enter A3 sub master code enter A9 default values 4 and 6 cdvi com cdvigroup com 19 To program Pin codes User location e m eo eo gt NJ ejeje e N Uj BR WIN REMINDER 00 to 99 User location 34 U W W NIOJ AJAJAJA UI aaj amp 4 U W WIN Fe u D A O U1 UI Ww U1 U1 U1 OIDI NII GALEO Relays 2 2 output Relay 1 From 00 to 59 Relay 2 From 60 to 99 NJN N NI NUT NU NI Co CO CO Co CO N WIN re NIO W N Co D Co U1 AIU N GALEO Relay 1 1 output Relay 1 From user location GALEO Relays 3 3 outputs Relay 1 From 00 to 59 Relay 2 From 60 to 79 cdvi com cdvigroup com 20 Relay 3 From 80 to 99 INSTALLATION MANUEL GALEO Illuminated Weatherproof Keypad with remote electronics 8 LIMITED LIFETIME WARRANTY EXTRACT CDVI warrants this product to be free from defects in material and workmanship when it has been installed in accordance with the ma
9. retourn au service apr s vente de CDVI apr s l obtention du num ro d autorisation de Retour de Produit s D fectueux RMA La responsabilit de CDVI se limite la r paration ou au remplacement d un produit ou pi ces d fectueuses en ses ateliers L une ou l autre de ces interventions sont d finis par le service apr s vente de CDVI Le pr judice imputable CDVI ne saurait en aucun cas d passer la valeur du produit La responsabilit de CDVI ne peut tre engag e aupr s de l acheteur installateur client final ou qui que ce soit lors dedommages cons cutifs des imperfections ou mauvais fonctionnement du produit Cette garantie prend effet la date d enregistrement du produit aupr s de CDVI partir de l instant ou la date d enregistrement est d ment compl t e dans la limite d un mois apr s la date de livraison au client final Pour obtenir les d tails complets de cette garantie et enregistrer votre vos produit s pour b n ficier de cette Garantie Vie limit e Veuillez compl ter la carte d enregistrement pr sente dans la boite du produit et nous la retourner par email ou par courrier l adresse de l entit CDVI la plus proche ou vous enregistrer en ligne l adresse www cdvigroup com Les contacts des entit s CDVI sont accessibles en ligne l adresse www cdvigroup com ou au dos de la notice d installation EXCLUSIONS DE LA GARANTIE Al EXCEPTION DES POINTS EVOQUES PRECEDEMMENT CDVI N APPLIQUE A
10. 2 jumper resets the keypad to factory default R1 Ci Ti R2 C2 T2 P1 M P2 PX E L values Remove the power 7 7 7 7 gt gt from the keypad then put 00000 the jumper see Programming section in the instruction manual ni Input voltage 12 to 24VAC or 12 to 48VDC Power supply According to lock specifications ss H Open mx Keypad mode Fail secure lock v Varistor Outputs Description H Close Request to Enter mode a DE ne mi ccm ra O i memesteew mutavi M Timer contact mew wire om keyed Green or Blue wire illumination Request to Exit inputs P1 request to exit input activates relay 1 P2 request to exit input activates relay 2 Latch or toggled output H input can be used with a timer to enable free access by pressing on any digit key on the keypad When the contact is open then the request to enter is disabled When the contact is closed then press any key on the keypad to enter cdvi com cdvigroup com Ce e m LR tue 15 n P3 jumper allows jl to the user to modify its own Pin code To enable this feature put the jumper on see Programming section in the instruction manual P2 jumper resets the keypad to factory default L values Remove the power from the keypad then put the jumper see Programming section NI in the in
11. 56 73 93 05 Reference G0301FR0234V05 Extranet EXE CDVI_IM GALEO CMYK A5 EN FR 04 GO 8 CDVI Group FRANCE Headquarter Si ge social Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBERICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 CDVI ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 39 70 CDVI MAROC Phone 212 0 5 22 48 09 40 Fax 212 0 5 22 48 34 69 Toutes les informations mentionn es titre indicatif sur le pr sent document photos dessins caract ristiques All the information contained within this document photos drawing features specifications and dimensions techniques et dimensions peuvent varier et sont susceptibles de modifications sans notification pr alable could be perceptibly different and can be changed without prior notice CDVI SWEDEN SWEDEN DENMARK NORWAY FINLAND Phone 46 0 31 760 19 30 Fax 46 0 31 748 09 30 CDVI UK UNITED KINGDOM IRELAND Phone 44 0 1628 531300 Fax 44 0 1628 531003 DIGIT FRANCE 33 0 1 41 71 06 85 Fax 33 0 1 41 71 06 86
12. FR FRANCAIS EY ENGLISH S Voir conditions de garantie vie limit e Refer to Limited Lifetime Warranty illuminati with Range Digicode Gamme Digicode INSTALLATION MANUAL MANUEL D INSTALLATION CDVI Group Products Merci pour l achat de ce produit et pour la confiance que vous accordez notre entreprise 1 PRESENTATION DU PRODUIT m Alliage d aluminium R tro clair m Faible encombrement De 2 a 3 relais HAUTE ANDALISME m Pose en applique m Free voltage m Montage avec vis Torx m Etanch it du clavier surmoul m Protection de la carte lectronique d port e par tropicalisation m 100 codes d acc s personnalisables individuellement par chaque utilisateur m Existe en version Wiegand GALEOW AUTE RESISTANCE m Signalisation lumineuse et sonore Dimensions x x P GALEO 110 x 75 x 15 mm Electronique d port e 147 x 124 x 55 mm m Alimentations 12 V 24 V AC et 12 V 48 V DC m Consommation 3 relais command s clavier En 12 V AC Au repos 90 mA En 24 V AC Au repos 46 mA En 12 V DC Au repos 100 mA En 24 V DC Au repos 55 mA En 48 V DC Au repos 30 mA 2 RAPPELS ET RECOMMANDATIONS Rappel de c blage La distance de c blage entre le GALEO et l lec tronique d port e doit tre au maximum de 10 m Attention de ne pas passer vos fils proximit de cables Courant fort ex
13. ILITY OR FITNESS FOR ANY PARTICULAR PURPOSE 9 NOTES Refer to Limited Lifetime Warranty conditions cdvi com cdvigroup com 21 Illumination duration 00 permanent 10 Default 1 x beep OK 4 beeps Error cdvi com 22 OI SE SOC 1 x beep OK 4 beeps Error cdvigroup com Enter Master code twice Time Relay 2 00 toggled 01 Default 1 x beep OK 4 beeps Error GALEO3R 1 x beep OK 4 beeps Error 1 x beep OK 4 beeps Error Master code Change master code 12345 Default 1 x beep OK 4 beeps Error INSTALLATION MANUEL GALEO Illuminated Weatherproof Keypad with remote electronics Sub master Sub master Sub master Buzzer Audible feedback User codes 00 99 4 or 5 digit code 2 E 2 2 O Buzzer disabled digits digits digits 4 beeps User 1 Buzzer location used AB default 13 default 46 default enabled 1 bips User location free 1 x beep OK 1 x beep OK 1 x beep OK 1 x beep OK 4 beeps Error 4 beeps Error 4 beeps 4 beeps Error Lac shee Os GALEO B cdvi com cdvigroup com 23 Creator of electronic access solutions CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0
14. UCUNE GARANTIE NI DELIBEREE NI TACITE A TOUS LES PROBLEMES INCLUANT LE CONDITIONNEMENT LE TRANSPORT LEUR COMMERCIALISATION OU LES CONDITIONS D UTILISATIONS PARTICULIERES 9 NOTES Voir conditions de garantie vie limit e cdvi com 12 cdvigroup com INSTALLATION MANUEL GALEO Illuminated Weatherproof Keypad with remote electronics Thank you for buying our products and for the confidence you placed in our company 1 GENERAL INFORMATION m Polished heavy duty Zamak cast alloy Backlit keys m 2 to 3 relays m Surface mount RESISTANCE m Free voltage TO VANDALISM Mounting with Torx screws Keypad sealed with epoxy m PCB of remote electronics protected with a varnish coating m 100 user codes customisable by each user m Available in Wiegand version GALEOW m Audible and visual feedback m Dimensions L x W x D GALEO 110 x 75 x 15mm Remote Controller 147 x 124 x 55 m Power supplies 12V to 24V ac and 12V to 48V dc Consumption when relay outputs activated and keypad illuminated 12V AC Standby 90mA 24V AC Standby 46mA 12V DC Standby 100mA 24V DC Standby 55mA 48V DC Standby 30mA 2 NOTES amp RECOMMENDATIONS Cable The distance between the GALEO and the remote electronic can not exceed more than 10 meters Make sure that the cable is not near by a high vol tage cables ex 230 V AC Recommended cable between the GALEO and
15. aitez passer d un code maitre et donc d un code utilisateur de 4 termes 5 termes suivez la m me proc dure Lors du passage de 4 5 termes le chiffre O sera int grer par d faut devant le code maitre et donc devant les codes utilisateurs Ex le passage du code 2 3 6 9 4 termes en 5 termes devient 0 2 3 6 9 Il est conseill de programmer les codes en 5 termes puis de modifier le nombre de termes C PROGRAMMATION DU CODE MAITRE 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code usine est 1 23 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez A5 Un bip est mis Tapez les 4 ou 5 termes du nouveau code Un bip sonore est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement D PROGRAMMATION DES CODES Suivant le nombre de relais de votre GALEO 1 2 ou 3 relais les groupes de codes appell s aussi rangs pour le classements des codes par individus sont diff rents GALEO 1 Relais Groupe 1 Du rang 00 au rang 99 GALEO 2 Relais Groupe 1 Du rang 00 au rang 59 Groupe 2 Du rang 60 au rang 99 GALEO 3 Relais Groupe 1 Du rang 00 au rang 59 Groupe 2 Du rang 60 au rang 79 Groupe 3 Du rang 80 au rang 99 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine
16. aster code 2 beeps are emitted to confirm entry in programming mode 2 Press A4 to program the code length One beep is emitted Press 4 or 5 for the digit code One beep is emitted to confirm programming of the code length 3 Press A5 to modify the master code One beep is emitted Enter the new 4 or 5 digit master code One beep is emitted to confirm pro gramming of the new master code 4 Press B to exit from programming mode 2 beeps are emitted to confirm that the keypad is in stand by operating mode 4 beeps indicate a data computing error C CHANGING THE MASTER CODE The master code is used only to enter in programming mode 1 Enter the master code twice 12 3 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode cdvi com cdvigroup com 17 2 Press A5 to modify the master code One beep is emitted Enter the new 4 or 5 digit master code One beep is emitted to confirm that the master code is programmed 3 Press B to exit from the programming mode 2 beeps are emitted to confirm that the keypad is in stand by operating mode D ADDING CHANGING OR DELETING A USER CODE Group 1 From address 00 to address 99 relay output 1 1 Enter the master code twice 123 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 To add a user code enter the user location from OO to 99 If the user location is free 1 beep is
17. confirm reset of all memory of the keypad Wait for two beeps The master code is restored to its default value 1 2 3 4 5 and all the User codes are deleted from the keypad Once the reset is completed then the keypad returns to a stand by operating mode OR 1 Cut the power Put the jumper on P2 2 Put the power back Wait approximately 3 seconds Two beeps are emitted to confirm reset of the keypad Remove P2 jumper The master code is restored to its default value 1 2 3 4 5 and all the User codes are deleted from the keypad B SETTING CODE LENGTH The buzzer indicates different audible signals It can be turned off by cutting the ST1 wire on the 1 short beep Keypad powered 1 long beep data computing in programming or access granted 2 short beeps Enter or Exit from The master code and the User codes can be of 4 or 5 digit in length All the keypad keys can be used to remote electronics program a code The master code and the Pin code can be of 4 or 5 digit code The master code CAN NOT be used as a PIN code User Pin code The master code CAN NOT be used as a PIN code User Pin code To delete a specific User pin Code replace it by 0000 if code length is 4 digit format or replace it by 00000 if the code is in 5 digit format P2 JUMPER Reset master code and user codes P3 JUMPER modification of individual code by the user a computing 1 Enter the master code twice 12 3 4 5 default value m
18. cordement du bouton poussoir P2 est pr vu pour commander le relais 2 Le mode et la temporisation sont programmables Le contact horloge H permet l utilisa tion de toutes les touches comme bou ton ext rieur Si le contact horloge est ouvert les touches sont utilis es comme des termes habituels Si le contact horloge est ferm toutes les touches sont utilis es pour l ouverture libre LE LEUTE OU Oooo GALEO en fonction clavier cod m MANUEL D INSTALLATION GALEO Clavier cod r tro clair lectronique d port e 7 SCH MA DE RACCORDEMENTS GALEO 3 RELAIS n Le cavalier sur P3 permet de changer jl le code d entr e par l utilisateur Le cavalier doit tre plac pour les modifications et enlev pour verrouiller cette option voir chapitre Programmation Le cavalier sur P2 permet de r aliser une remise z ro de la m moire Le cavalier doit tre plac hors tension pour que la manipulation fonctionne voir chapitre Program mation Alimentation 12 24 V AC ou 12 48 V DC Alimentation c t puissance de commande Sortie Correspondance Ri Contact repos durelaist ci Commundurelaist SSCS R2 Contact repos du relais Commun dures R3 Contact repos du reiss Commundurelais3 Pi Bouton int rieur de sortie rest M Commun boutons
19. ess 7 to program a sub master code for the user individual Pin code modification One beep is emitted Enter the new 2 digit sub master code One beep is emitted to confirm programming of the sub master code 3 Press B to exit from the programming mode 2 beeps are emitted to confirm that the keypad is in stand by operating mode I Audible Feedback The audible signal is enabled in programming mode and when the relay is energised after a valid code To enable the audible feedback on a key press 1 Enter the master code twice 12345 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press AA One beep is emitted Press O to disable the audible signal during a keypress Press 1 to enable the au dible signal during a keypress One beep confirms the new setting 3 Press B to exit from programming 2 beeps are emitted to confirm exit from programming mode J OPTIONAL GALEO 2 AND GALEO 3 PROGRAMMING INSTRUCTION Programming instructions are the same as for the GALEO keypad with 1 relay output GALEO 2 2 relay outputs N O and N C contacts 250V Group 1 From user location 00 to user location 59 to activate relay 1 Group 2 from user location 60 to user location 99 to activate relay 2 Release Time of relay2 enter A2 sub master code enter A8 default values 1 and 3 GALEO 3 3 relay outputs N O and N C contacts 8A 250V Group 1 from user location 00 to user
20. ments Lors de cette op ration n oubliez pas de placer la varistance Voir page 2 Rappels et pr conisations cdvi com cdvigroup com 3 n Le cavalier sur P3 permet de changer l utilisateur Le cavalier doit tre plac pour les modifications et enlev pour verrouiller cette MI option voir chapitre Programmation Le cavalier sur P2 permet de r aliser une remise z ro de la m moire Le cavalier doit tre plac hors tension pour que la manipulation fonctionne voir chapitre Program mation Alimentation 12 24 V AC ou 12 48 V DC Alimentation c t puissance de commande Sortie Correspondance ME Alimentation 12V 24V AC ou 12V 48V DC Alimentation 12V 24V AC ou 12V 48V m cwmereesdreasi e commindureiss ma contact repos dures commun aus pa Bouton m reur de sortie resi Pm commun boutons Ci Bouton int reur de sortie resi m i P pones Clavier vert ou bleu clairage cdvi com 4 cdvigroup com Electronique d port e jl le code d entr e par R2 C2 T2 P1 M P2 H Ouvert 1 G che rupture re Contact au repos G che mission H Ferm v Varistance GALEO en fonction Bouton Poussoir Commande par bouton poussoir Le raccordement du bouton poussoir P1 est pr vu pour commander le relais 1 Le rac
21. mmation 4 bips courts Erreur de saisie TERMES UTILIS S ET CODES D OUVERTURE Toutes les touches du clavier sont autoris es pour composer Le code maitre et les codes d ouverture de porte doivent tre compos s de 4 ou 5 termes Le code maitre ne peut pas tre utilis comme code d ouverture Les codes 00000 et 0000 servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte CAVALIER P2 Code maitre 1 2 3 4 5 et RAZ des codes CAVALIER P3 Modification des codes let3 les codes A REMISE Z RO DE LA M MOIRE 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code usine est 1234 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Puis tapez A6 Un bip sonore est mis 3 Tapez Aet B La remise z ro est valid e Attendez que deux bips soient mis Le code maitre est de nouveau 1 2 3 4 5 et tous les codes sont effac s Le clavier est sorti de programmation et les valeurs par d faut sont r tablies Vous avez aussi une seconde possibilit pour remettre z ro la m moire 1 Coupez l alimentation et positionnez un cavalier en P2 Pour avoir plus de pr cision sur l emplacement du cavalier P2 reportez vous la page 4 2 R tablir l alimentation Attendre environ 3 secondes 2 bips sonores sont mis pour confirmer la remise z ro Enlevez le cavalier P2 Le code maitre est de
22. nores sont mis pour confirmer l entr e en programmation 2 Tapez AA Un bip est mis Tapez O pour supprimer les bips touches pendant la composition du code d ouverture Tapez 1 pour autoriser les bips touches pendant la composition du code d ouverture Un bip sonore est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sonores sont mis pour confirmer le retour au mode normal de fonctionnement MANUEL D INSTALLATION GALEO Clavier cod r tro clair lectronique d port e Ci joint un tableau r capitulatif qui vous servira indiquer le code attribu chaque utilisateur GALEO 1 Relais GALEO 2 Relais GALEO 3 Relais Groupe 1 Du rang 00 au rang 99 Groupe 1 D rang 00 au rang 59 Groupe 1 Du rang 00 au rang 59 RAPPEL Groupe 2 D rang 60 au rang 99 Groupe 2 Du rang 60 au rang 79 Groupe 3 Du rang 80 au rang 99 cdvi com cdvigroup com 11 Les soci t s CDVI garantissent que ce produit est d pourvu de tout vice cach tant dans les mat riaux que dans sa fabrication la condition qu il soit install conform ment aux pr conisations du fabricant et qu il n y ait pas eu d interventions ou de modifications sur le produit La responsabilit de CDVI se limite la r paration ou l change du produit CDVI n assume aucune responsabilit concernant les dommages sur les biens ou les personnes Un produit reconnu d fectueux par CDVI doit tre
23. nouveau 1 23 45 et tous les codes sont effac s Les valeurs par d faut sont r tablies cdvi com 8 cdvigroup com par l utilisateurs B PROGRAMMATION DU CODE MAITRE ET DU NOMBRE DE TERMES 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12 3 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez A4 pour la saisie du nombre de termes des codes Un bip est mis Tapez 4 ou 5 pour le nombre de termes Un bip sonore est mis pour confirmer la programmation 3 Tapez A5 pour changer le code maitre Un bip est mis Tapez les 4 ou 5 termes du nouveau code Un bip sonore est mis pour confirmer la programmation 4 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement 4 bips indiquent une erreur de saisie Cas de figure Vous avez un code maitre et des codes utilisateurs a 5 termes Vous souhaitez utiliser des codes a 4 termes Vous faites donc la d marche indiqu e ci dessus en modifiant le code maitre Lorque le nombre de terme du code maitre est bien pass de 5 a 4 termes les codes utilisateurs deviennent simultan ment des codes 4 termes MANUEL D INSTALLATION GALEO Clavier cod r tro clair lectronique d port e eee Ex Si votre code ma tre et code utilisateur est 12 3 6 9 il deviendra apr s manipulation 2 3 6 9 Si vous souh
24. nufacturer s instructions and has not been modified or tampered with Only product recognized by CDVI to be defective should be returned under these warranty terms if accompanied by an RMA Return Material Authorization Number provided by CDVI CDVI at its option shall repair or replace the defective product at CDVI premises or at any CDVI approved service center This warranty does not cover any damage due to accident misuse abuse or negligence This warranty is valid only if the product is registered within 1 month from delivery to the final costumer To obtain full details of this warranty and to register the product to commence the Limited Lifetime Warranty complete the enclosed registration card and return it either by e mail or post to the relevant CDVI address or completion of the on line registration at www cdvigroup com Repair or replacement of the defective product is the exclusive remedy CDVI shall not be liable for any incidental or consequential damages arising from any defect in or malfunction of its product In no event the entire liability can not exceed the purchase price of the product The CDVI local country contact details can be found on line by visiting www cdvigroup com or on the back cover of the installation manual DISCLAIMER OF WARRANTY EXCEPT AS STATED ABOVE CDVI MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED AS TO ANY MATTER WHATSOEVER INCLUDING THE CONDITION OF ITS PRODUCTS THE TRANSPORTATION THEIR MERCHANTAB
25. r 99 seconds Press 00 for a toggled output One beep is emitted to validate the time 4 Press B to exit from programming mode 2 beeps are emitted to confirm that the keypad is in stand by operating mode 4 beeps indicate a data computing error F RESET MASTER CODE On stand by operating mode put a jumper on P2 Wait 1 second and then remove the jumper One beep is emitted The master code is restored to its default value 1 2 3 4 5 in 5 digit code and 1 23 4 in 4 digit code G CHANGING THE CODE BY A USER To authorize a user to modify its own User code put a jumper on P3 to disable the feature remove the jumper 1 Enter the old user code The relay is activated and a beep is emitted 2 Enter the 2 digit sub master code default sub master code A and B A beep is emitted to authorise the modification 3 Enter the new user code 2 beeps are emitted to confirm the new code INSTALLATION MANUEL GALEO Illuminated Weatherproof Keypad with remote electronics 4 Check the new user code to be sure of the modification H SETTING A SUB MASTER CODE The Sub Master code allows the user to change its own code without entering in programming mode For security reasons the code need to be changed periodically This feature makes it easier and faster to change its code 1 Enter the master code twice 1234 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Pr
26. rifiez la distance entre le GALEO et son lectronique d port e Voir page 2 Rappels et pr conisations A l aide de la plaque de fixation de l lectronique d port e et du GALEO prenez les marques et percez les 2 trous de fixation for t 5 mm et profondeur minimum 35 mm ainsi que l ouverture pour le passage du cable lectrique destin au clavier IO OS SEC Bloquez le GALEO sur son support par l interm diaire de la vis TORX et de son outil sp cifique cl m le coud e Pour finaliser le montage de ce produit placez le cache vis Vis Torx Cl Vis t te coud e cruciforme frais e pour vis t te frais e M4x10 Torx T20 M4x30 Positionnez les 2 chevilles plastiques dans les trous Puis Fixez le fond du GALEO sur le support de votre choix a l aide des vis cruciformes t tes frais es Positionnez les 2 chevilles plastique dans les trous Puis fixez la plaque de fixation de l lectronique d port e sur la surface de votre choix l aide des vis cruciformes t tes frais es Venez ensuite placer l lectronique d port e sur son support Plaque de fixation de l lectronique d port e Cheville plastique Ier SE SOC Passez le c ble lectrique du GALEO dans son ouverture et fixez le son support par le haut avec le crochet sup rieur Passez vos fils glissez les passe fils de l lectronique d port e et faites vos branche
27. struction manual Input voltage 12 to 24VAC or 12 to 48VDC Power supply According to lock specifications Outputs Description cdvi com 16 cdvigroup com D 693 Remote electronics 4 D 1 4 D 4 T1 R2 C2 T2 R3 C3 T3 P1 M P2 m muse H Open i i Fail safe lock Keypad mode Fail secure lock H Close Request to v Varistor Enter mode Request to Exit inputsH input can be used with a timer to enable free access by pressing on any digit key on the keypad LE LEE ET OU EE LETT ET ooo SOS re INSTALLATION MANUEL GALEO Illuminated Weatherproof Keypad with 7 PROGRAMMING DEFAULT VALUES Without codes Illumination time 10 seconds Relay release time 1 second Code length 5 digit Master Code 12 34 5 Programming security time 120 secondes Code length for sub master code m Version 1 relay Group 1 AUDIBLE SIGNAL remote controller programming A and B 4 short beeps dat m Version 2 relays Group 2 error 1 3 m Version 3 relays Group 3 CODE LENGTH 4 and 6 A RESET MASTER CODE AND USER CODES 1 Enter the master code twice 123 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press A6 to reset the Master Code and the User codes One beep is emitted Press on A and B to
28. t le retour un fonctionnement normal 4 V rifiez la m morisation du nouveau code en le composant H PROGRAMMATION DES TERMES DE MODIFICATIONS cdvi com 10 cdvigroup com 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12 3 4 5 Deux bips sont mis pour confirmer l entr e en programmation 2 Relais 1 Groupe 1 Tapez A7 Relais 2 Groupe 2 Tapez A8 Relais 3 Groupe 3 Tapez A9 Suivant le nombre de relais cette saisie vous permettra de composer les nouveaux termes de modifications des codes utilisateurs pour chaque groupe Un bip est mis Tapez les deux termes de modification Un second bip sonore est mis pour confirmer la programmation Ex GALEO 3 Relais Tapez A7 puis composez les deux termes de modifications Puis r p tez l op ration en tapant A8 et une nouvelle fois en composant A9 3 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement I PROGRAMMATION DU SIGNAL SONORE Le signal sonore est toujours audible en programmation Il en est de m me lors de la commande d ouverture suite la reconnaissance d un code Par d faut lors de la composition du code d ouverture aucun bip sonore touche n est audible Il est possible d autoriser les bips a sonores touches 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12 3 4 5 Deux bips so
29. the remote electronic To expand the supplied 3 meter cable select a 2 twisted pairs cable 4 wires SYT1 0 8MM AWG 20 Recommended power supplies suitable for the GALEO ARD12 230V input BS60 230V input 28 83 Environmental tests vibrations WEEE e a Environmental test Salt spray i 164 NEN 2 C CE certification 25 C to 70 C REMOTE CONTROLLER C CE certification d IP52 WEEE 20 C to 70 Mounting recommendations Mount the keypad on a flat surface to avoid any vandalism and to insure the best mounting Security advice For security advice reasons change the factory default master code When selecting a master code and user code avoid sequencial codes example 3 4 5 6 7 Back EMF protection To secure the system from back electromagnetic fields do not forget to mount the varistor in parallel on the lock Tension libre cdvi com cdvigroup com 13 GALEO Remote Controller 4 MOUNTING Verify the distance between the GALEO keypad and its remote electronic Refer to page 2 Notes and Recommendations Place the back plate of the GALEO on the wall and the bracket of the remote electronic then mark with a pen the hole location then drill the 2 mounting holes drill bit 5 mm and 35 MM hole depth and the hole wiring access OS SEC Fasten the GALEO keypad to the back