KCPROXWLC - Easy Catalogue
Contents
1. Strike M magnet M varistor Input voltage selection Two different configurations are possible 12VDC only As standard p Cut the strap 12VAC or 24VDC cdvi com 4 cdvigroup com Door contact not used Connect E and M Shielded cable INTBUSW To other door controllers INTBUSW MANUEL D INSTALLATION EN KCPROXWLC Dual Technology Digicode Proximity reader Wiegand INTBUSW Reader controller Terminal block Motherboard v Input voltage 12 Input voltage 1 Data O 2 Clock 3 Data 1 Terminal block Motherboard R N C contact eletromagnetic lock Common contact power supply N O contact electric release N C contact alarm ajajaja Common T N O contact alarm Input voltage DC or AC 12V or 24V P1 Request to enter input Without jumper without clock With jumper with clock M Common P1 et P2 P2 Request to enter input Door contact N C Door closed and N O Door open E L Reader activation imput N O reader enabled and N C reader disabled M Common E and M or E and L A RS485 Bus All the A must be connected together in daisy chain B RS485 Bus All the B must be connected together in daisy chain Terminal block 3 points Piggyback bo
2. cdvi com 16 cdvigroup com Si vous ne souhaitez pas de gestion de l etat porte Relier E et M INTBUSW Vers d autres contr leur de portes INTBUSW MANUEL D INSTALLATION FR Lecteur double Technologie Proximit Digicode Wiegand INTBUSW Contr leur de porte Bornier 5 points Carte m re v Alimentation 12 Alimentation 1 Data O 2 Clock 3 Data 1 Bornier 16 points Carte m re R Contact N F porte Ventouse Contact commun Alimentation C T Contact N O porte G che R Contact N F alarme C Contact commun T Contact N O alarme Alimentation DC ou AC 12 V ou 24 V DC Pi Bouton poussoir int rieur M Masse commune P1 et P2 Sans cavalier Avec cavalier P2 Bouton poussoir ext rieur Contact fermeture porte N F Porte ferm e et N O Porte ouverte E L Contact autorisation lecture du badge N O autoris e et N F interdite M Masse commune E et M ou E et L A Bus RS485 tous les A doivent tre reli s entre eux sous la forme d une cha ne B Bus RS485 tous les B doivent tre reli s entre eux sous la forme d une cha ne 7 Buzzer 8 Signalisation gt couleur verte 9 Signalisation gt couleur rouge MODE AUTONOME
3. Sorties Correspondances Correspondances ct vgo0 a LT20PB LT20AC UCA3 PROMI1000 Format Wiegand Format ISO2 Format Standard LT20PBIP LT20IP PROMI1000PC Alimentation Alimentation Alimentation ROUGE pe 12V DC 12V DC 12V 12VDC 12VDC 12VDC 12 VDC NOIR Alimentation OV Alimentation OV Alimentation OV RUN ov ov ov ov Commande Commande Commande OUT5 LARON ext rieur du buzzer du buzzer du buzzer OUT6 R1 D0 VERT DATA 0 CODE R2 D0 cL cL R1 D1 BLANC DATA 1 DATA R2 D1 DA DA BLEU CLOCK CLOCK STANDARD 1 WIRE 8 ou 18 1 VIOLET PROGRAMMATION PROGRAMMATION PROGRAMMATION JAUNE VOYANT VERT VOYANT VERT VOYANT VERT ourl ORANGE VOYANT ROUGE VOYANT ROUGE VOYANT ROUGE oute cdvi com cdvigroup com 15 Rouge Alimentation 12V DC Noir Alimentation OV Marron Commande du buzzer Vert Data 0 Blanc Data 1 Bleu Clock Violet Voyant vert Programmation Orange Voyant rouge Orange Jaune Blanc vert Bleu of Rouge Noir Qeon Marron Ky Violet Connexion C ble Violet KCPROXWLC et Noir pour la programmation G che M ventouse M varistance Alimentation Pour l alimentation il y a deux modes possibles 12 V DC uniquement Configuration usine p Coupez le strap 12 V AC ou 24 V DC
4. KEYPAD CODE Exemple avec un code clavier 4 termes 1 3 7 5 puis B 1 0000 0000 0001 0011 0111 0101 0 D cimal Parit 1 0 0 1 3 7 5 Parit 2 Hexad cimal Parit 1 0 0 0 5 5 F Parit 2 Exemple avec un code clavier 5 termes 7 1 3 7 5 puis B D cimal Parit 1 0 7 1 3 7 5 Parit 2 Hexad cimal Parit 1 0 1 1 6 C F Parit 2 Exemple avec un code clavier 6 termes 6 7 1 3 7 5 puis B D cimal Parit 1 6 7 1 3 7 5 Parit 2 Hexad cimal Parit 1 0 A 3 E 8 F Parit 2 Parit 1 0 si le nombre de 1 dans bit 2 bit 13 est paire 1 si le nombre de 1 dans bit 2 bit 13 est impaire cdvi com 22 cdvigroup com MANUEL D INSTALLATION FR KCPROXWLC Lecteur double Technologie Proximit Digicode Wiegand Parit 2 0 si le nombre de 1 dans bit 14 bit 25 est impaire 1 si le nombre de 1 dans bit 14 a bit 25 est paire CODE BADGE FX ee Parit 1 1 9 8 A A D Parit 2 10 FORMAT DE SORTIE WIEGAND 30 BITS Structure et description du message Format 30 bits hexad cimal La communication s effectue par une liaison de type Wiegand 30 bits Signaux DATA1 et DATAO La trame est constitu e d une totalit de 30 bits et se d compose comme suit Parit 1 1 bit parit paire des 14 premiers bits Code 7 quartets repr sen
5. KCPROXWLC mu Range Integrated Access Control Gamme Contr le d Acc s Int gr INSTALLATION MANUAL MANUEL D INSTALLATION CDV I Group Products ILC PP er ology Digicode Proximity reader Wiegand 1 PRODUCT PRESENTATION m Dual technology Proximity reader Digicode keypad m Output formats Wiegand Standard format ISO Track 2 format E Stainless steel m Narrow Ideal for installation on aluminium profile m Backlit m Recommended for activating and deactivating your alarm system E Surface mount m Mounting with Diax screws m Audible and visual feedback m Dimensions L x W x D 190 x 43 x 27mm m Power supplies 12V dc m Consumptions 120mA T G is Environmental tests vibrations 25 C 70 C WEEE amp RoHS 2 NOTES amp RECOMMENDATIONS Operating modes a CENTAUR 3 operating user modes with CENTAUR Digicode keypad only Proximity reader only or dual security Proximity reader Digicode keypad The operating mode is programmed on Centaur software TERENA UGM UGL There are only 2 operating modes possible on TERENA or UGL UGM Digicode keypad Proximity card reader Program the proximity card or the pin code on TERENA or UGL UGM software Cable Programming your installation before installing products on site The distance between a CT V900 A controller or a LINKNET controller and a KCPROXWLC should n
6. rok ULL Di pit lt gt Time 25 50 OF BIT TIME Each digit is made of 5 bits 4 bits data 1 bit parity Characters m 0 0 0 0 1 0 0 0 1 0 2 0 0 1 0 0 3 0 0 1 1 1 4 0 1 0 0 0 5 0 1 0 1 1 6 0 1 1 0 1 7 0 1 1 1 0 8 1 0 0 0 0 9 1 0 0 1 1 A 1 0 1 0 1 B SS 1 0 1 1 0 c 1 1 0 0 1 D FD 1 1 0 1 0 E 1 1 1 0 0 F ES 1 1 1 1 1 cdvi com 12 cdvigroup com MANUEL D INSTALLATION EN KCPROXWLC Dual Technology Digicode Proximity reader Wiegand cdvi com cdvigroup com 13 1 PRESENTATION DU PRODUIT m Double technologie Lecteur proximit Digicode m Format de sorties Wiegand Standard et ISO Track 2 E Inox m Etroit Id al pour la pose sur profil Aluminium m R tro clair m Pr conis pour l activation et la d sactivation de votre syst me d alarme m Pose en applique m Montage avec vis Diax m Carte lectronique r sin e Signalisation lumineuse et sonore Dimensions L x x P 190 x 43 x 27 mm Alimentations 12 V DC Consommations 120 mA 2 NOTES amp RECOMMENDATIONS Programmation de la double s curit a CENTAUR Il y a 3 modes d utilisation du KCPROXWLC Digicode seul Le lecteur proximit seul ou la double s curit Digicode lecteur proximit La programmation des modes est programm e sur le logiciel CENTAUR T
7. TELACCESS TERENA Programmation de l adresse par dipswitch 7 UGM UGL Dip4 ON UGP 40 PDN345BUSPROX Adressage DIPSWITCH 1 2 3 4 Mode ON ON ON ON Fa ade Programmation de l adresse par installation OFF ON ON ON Lecteur 1 Dip4 OFF ON OFF ON ON Lecteur 2 OFF OFF ON ON Lecteur 3 ST1 Cavalier de programmation ON ON OFF ON Lecteur 4 ST1 Cavalier de programmation Normal E m Si i BL 123 123 123 Normal Config usine Installation cdvi com cdvigroup com 17 8 PROGRAMMATION Connexion du c ble Violet et Noir pour entrer en programmation Coupez l alimentation puis r tablissez la e 6e0e80 000009 2 bips sonores LED rouge ON Programmation du format de sortie Programmation de l clairage 1 bip 1 bip LED verte ON LED verte ON Tapez la dur e 1 bip LED verte ON de commande en secondes ou OO pour un clairage permanent 1 bip OK LED verte ON 4 bips Erreur 1 Format Wiegand 2 Format Standard 3 Format ISO Track 2 1 bip OK LED verte ON 4 bips Erreur Tapez 4 5 ou 6 pour d finir le nombre de termes 1 bip OK LED verte ON 4 bips Erreur Programmation du nombre de bits LED verte ON Tapez 26 30 ou 44 pour le nombre de bits du code Wiegand 1 bip OK LED verte ON 4 bips Erreur y cdvi com 18 cdvigroup co
8. cdvi com cdvigroup com 27 Extranet EXE CDVI_IM KCPROXWLC CMYK A5 EN FR 04 Manufacturing Access Control CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 62 02 50 Fax 32 0 56 62 02 55 Reference G0301FR0334V04 CDVI Group FRANCE Headqua Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 cDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SWITZERLAND Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 87664065 Fax 86 0 10 87664165 CDVI IB RICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 Lei 4 1 ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 39 70 CDVI MAROC Phone 212 0 5 22 48 09 40 Fax 212 0 5 22 48 34 69 v D a kz T ka p q S a a a o 1 a fe re oO E 2 D 2 o a oO 5 a a a w i6 o 2 5 0 n D Sa E 5 o a a S 5 w E o ee wn v g 8 lt 2 All the information contained within this document photos drawing features specifications and dimensions could be perceptibly different and can be changed without prior notice CDVI SWEDEN SWEDEN DANEMARK NORWAY FINLAND Phone 46 0 3
9. Press 2 to select Standard output format Press 3 to select ISO Track 2 output format One beep is emitted to confirm programming The Green LED is lighting up during 1 second Disconnect the purple cable with the black cable Two beeps are emitted to confirm exit from programming D CODE LENGTH 1 2 Enter in programming Enter in programming Press A2 to enter in the code length setting menu One beep is emitted The Green LED is lighting up during 1 second Press 4 for a 4 digit user code press 5 for a 5 digit user code or press 6 for a 6 digit user code One beep is emitted to confirm programming The Green LED is lighting up during 1 second Disconnect the purple cable with the black cable Two beeps are emitted to confirm exit from programming PROGRAMMING THE BIT FORMAT Press A3 to select the Bit format One beep is emitted The Green LED is lighting up during 1 second Enter 26 30 or 44 to define the bit format MANUEL D INSTALLATION EN KCPROXWLC Dual Technology Digicode Proximity reader Wiegand One beep is emitted to confirm programming 3 Disconnect the purple cable with the black cable The Green LED is lighting up during 1 second Two beeps are emitted to confirm exit f ing 3 Disconnect the purple cable with the black cable POM programming Two beeps are emitted to confirm exit H AUDIBLE SIGNAL from programming 1 Enter in prog
10. 1111 0000 0001 0001 1001 1000 1010 1010 1101 12 FORMAT DE SORTIE FORMAT STANDARD Le KCPROXWLC fonctionne sous ce format propri t de l entreprise avec certaines centrales ou platines de la gamme Standard nous consulter 13 FORMAT DE SORTIE FORMAT ISO 7811 TRACK 2 SS Sentinelle de d but gt Hex B ES Sentinelle de fin gt Hex F LRC Ou Exclusif de tous les caract res de la trame y compris SS et ES Caract res Le nombre de caract res est fix 8 En 4 termes 00001234 En 5 termes 00012345 En 6 termes 00123456 Pr sence E Data Clock met o s Time i 25 50 OF BIT TIME cdvi com 24 cdvigroup com MANUEL D INSTALLATION KCPROXWLC Lecteur double Technologie Proximit Digicode Wiegand Chaque caract re est compos de 5 bits 4 bits de donn es 1 bit de parit Caract res B4 B3 B2 B1 Parit o 0 0 0 0 1 1 0 0 0 1 0 2 0 0 1 0 0 3 0 0 1 1 1 4 0 1 0 0 0 5 0 1 0 1 1 6 0 1 1 0 1 7 0 1 1 1 0 8 1 0 0 0 0 9 1 0 0 1 1 A 1 0 1 0 1 B SS i 0 1 1 0 1 1 0 0 1 D FD 1 1 0 1 0 E 1 1 1 0 0 F ES 1 1 1 1 1 cdvi com cdvigroup com 25 T schnologie Proximit Digicode Wiegand cdvi com 26 cdvigroup com MANUEL D INSTALLATION FR KCPROXWLC Lecteur double Technologie Proximit Digicode Wiegand
11. Error Programming the Bit format 1 beep Green LED ON Enter 26 30 or 44 to define the Bit number of the Wiegand format 1 beep OK Green LED ON 4 beeps Error y cdvi com 6 cdvigroup com MANUEL D INSTALLATION KCPROXWLC Dual Technology Digicode Proximity reader Wiegand Programming Centaur or Standard format 1 beep Green LED ON Enter 0 Centaur mode 1 Standard format 1 beep OK Green LED ON 4 beeps Error Programming for decimal or hexadecimal mode A5 1 beep Green LED ON Enter 0 for decimal mode 1 for hexadecimal mode 1 beep OK Green LED ON 4 beeps Error Programming the audible signal 1 beep Green LED ON Enter 0 disable the keypad beeps 1 Enable the keypad beeps 1 beep OK Green LED ON 4 beeps Error For the programming connect the purple cable with the black cable Switch the power supply off then switch it on 2 beeps are emitted cdvi com cdvigroup com Default values Illumination duration 10 seconds User code lenght 5 digits 26 bit wiegand output Buzzer disabled Decimal mode Audible Signal 1 short beep gt keypad powered and key presses 1 long beep gt data computing in programming A ENTRY IN PROGRAMMING 1 Enter in programming Swich the power supply off Connect the purple cable with t
12. l alimentation placer une r sistance de 120 ohms entre A et B sur le dernier contr leur de porte du BUS RS485 Composition des codes Par soucis de s curit veillez modifier le code maitre usine par celui de votre choix Lors du changement du code maitre usine et de la cr ation des codes utilisateurs vitez les codes trop simples ex les suites 3 4 5 6 7 MANUEL D INSTALLATION KCPROXWLC Lecteur double Technologie Proximit Digicode Wiegand 3 KIT DE MONTAGE se ct Vis cruciforme a t te enone ar age ee Fa coe r A Vis Diax a t te frais e Cl male coud e pour vis Cheville plastique M5x8 Diax frais e M4x30 1 1 2 2 4 MONTAGE de gt 0 ce 95 0 ee re 016 Les e a3 Lt a a g5 o at Prenez les c tes du support de fixation du KCPROXWLC Vissez le support de fixation dans la surface l aide des 2 vis et chevilles fournies C blez le KCPROXWLC Sch ma page suivante et positionnez le sur le support Pour finaliser la fixation du KCPROXWLC utilisez la vis et l outil Diax et percez la surface du de fixation mur Pr voyez la sortie des c bles cach s dans la sur face Raccordement aux bornier des centrales Format Standard Format Wiegand
13. mis La Led verte s allume pendant 1 seconde Tapez la dur e de commande en secondes 10 pour 10 secondes a 99 pour 99 secondes ou tapez 00 pour obtenir un clairage permanent Un bip de validation est mis 3 S parer le fil violet du fil noir Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement C PROGRAMMATION DU FORMAT DE SORTIE 1 Entrez en programmation Le clavier est clair La LED rouge est allum e 2 Tapez A1 pour choisir le format de sortie Un bip est mis ble Technologie Proximit Digicode Wiegand 4 bips courts gt Erreur de saisie Termes utilis s Les codes utilisateurs doivent tre compos s de 4 5 ou 6 termes En mode d cimal seuls la touche B est interdite pour composer les codes Touche B pour valider En mode hexad cimal seuls les touches de 0 a 9 sont autoris es pour composer les codes Touche B pour valider L utilisateur doit composer son code puis appuyer sur la touche B pour valider La LED verte s allume 1 seconde Tapez 1 pour une sortie au format i Wiegand i Tapez 2 pour une sortie au format Standard Tapez 3 pour une sortie au format ISO Track 2 Un bip de validation est mis la LED verte s allume 1 seconde 3 S parer le fil violet du fil noir Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement D PROGRAMMATION DU NOMBRE DE TERMES 1 Entre
14. 1 760 19 30 Fax 46 0 31 748 09 30 CDVI UK UNITED KINGDOM IRELAND Phone 44 0 1628 531300 Fax 44 0 1628 531003 DIGIT FRANCE Phone 33 0 1 41 71 06 85 Fax 33 0 1 41 71 06 86 techniques et dimensions peuvent varier et sont susceptibles de modifications sans notification pr alable
15. 5 Then B Decimal Parity 1 6 7 1 3 7 5 Parity 2 Hexadecimal Parity 1 0 A 3 E 8 F Parity 2 Parity 1 0 if the number of 1 in bit 2 to bit 13 is even 1 if the number of 1 in bit 2 to bit 13 is odd Parity 2 0 if the number of 1 in bit 14 to bit 25 is odd 1 if the number of 1 in bit 14 to bit 25 is even BADGE CODE FX ONE TIBRAD Parity 1 9 Parity 2 10 30 BIT WIEGAND FORMAT Signals output in open collectors with pull up in 30 bit hexadecimal format The output format from the proximity reader is 30 bit wiegand Signal DATA1 DATAO and CLOCK and is structured as follow Parity 1 1 bit even parity for the first 14 bit Code A code is formed from 7 half byte Each byte is transferred from bit 7 to bit 0 cdvi com 10 cdvigroup com MANUEL D INSTALLATION KCPROXWLC Dual Technology Digicode Proximity reader Wiegand Parity 2 1 bit odd parity for the last 14 bit Bit 1 Bit 2 a bit 29 Bit 30 Even Parity from bit 2 to bit 15 Data 28 bit Odd Parity from bit 16 to bit 29 KEYPAD BADGE CODES Example Badge OF01198AAD 6 DIGIT Keypad code 6 7 1 375 Then B KEYPAD CODE 1 0001 0001 1001 1000 1010 1010 1101 0 Parity 1 1 1 9 8 A A D Parity 2 Decimal Parity 1 0 6 7 1 3 7 5 Parity 2 Hexadecimal Parity 1 0 0 A 3 E 8 F Pa
16. ERENA UGM UGL Les centrales TERENA et UGM UGM permettent d utiliser le KCPROXWLC en mode Digicode ou lecteur proximit La programmation des modes est programm e sur les logiciels TERENA et UGM UGL Rappel de c blage Programmez votre installation au pr alable avant de l installer sur site Dans le cas d une connexion directe la centrale CT V900 A CENTAUR ou une des centrales LINKNET le KCPROXWLC doit tre plac une distance maximale de 50 m Dans les autres situations la distance entre le KCPROXWLC et le contr leur de porte INTBUSW doit tre de 50 m maximum et la distance entre cdvi com 14 cdvigroup com 190 6666 Digiprox OOOO CE Certification CE D 164 Test vibrations 25c 70c y A x DEEE amp RoHS 43 27 la centrale ou platine jusqu au dernier contr leur de porte INTBUSW peut atteindre 1200 m maximum Attention de ne pas passer vos fils proximit de c bles Courant fort ex 230 V AC C bles pr conis s entre le KCPROW WLC et l interface BUS INTBUSW C bles 2 paires 4 fils SYT1 8 10 me Montage Afin d optimiser la fixation du KC PROX WLC et de pr venir les tentatives d arrachage privil giez les surfaces planes Recommandations d installation Pour s curiser l installation n oubliez pas de placer la varistance sur le syst me de verrouillage en parall le au niveau de
17. ard 7 Buzzer 8 LED gt Green color 9 LED gt Red color STAND ALONE MODE TELACCESS TERENA Dipswitch address set up UGM UGL Dip4 ON UGP 40 PDN345BUSPROX DIP SWITCH adressing 1 2 3 4 Mode ON ON ON ON Front plate Address programming during installation OFF ON ON ON Reader 1 Dip4 OFF ON OFF ON ON Reader 2 OFF OFF ON ON Reader 3 ST1 Programming jumper ON ON OFF ON Reader 4 ST1 Programming jumper Normal IE m Prog g jumper Nor a RE 3 123 Normal As standard Installation cdvi com cdvigroup com 5 8 PROGRAMMING CHART e 6e0e80 000009 logy Digicode Proximity reader Wiegand For the programming connect the purple cable with the black cable Switch the power supply off then switch it on 2 beeps are emitted Red LED ON j Programming illumination keypad 1 beep Green LED ON Programming the output format 1 beep Green LED ON Enter the illumination time in seconds or 00 for a permanent illumination 1 beep OK Green LED ON 4 beeps Error Enter 1 Wiegand format 2 Standard format 3 ISO Track 2 format 1 beep OK Green LED ON 4 beeps Error Programming the code lenght 1 beep Green LED ON Enter 4 5 or 6 to specify the number of digits 1 beep OK Green LED ON 4 beeps
18. conde Tapez 0 pour un fonctionnement en mode Centaur ou tapez 1 pour s lectionner le mode Standard Un bip est mis pour confirmer la programmation La Led verte s allume pendant 1 seconde 3 S parer le fil violet du fil noir Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement G PROGRAMMATION DU MODE D CIMAL OU HEXADECIMAL 1 Entrez en programmation Le clavier est clair La LED rouge est allum e 2 Tapez A5 pour la saisie du mode Un bip est mis La Led verte s allume pendant 1 seconde Tapez 0 pour le mode d cimal et 1 pour le mode h xad cimal Un bip est mis pour confirmer la programmation La Led verte s allume pendant 1 seconde 3 S parer le fil violet du fil noir Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement H PROGRAMMATION DU SIGNAL SONORE 1 Entrez en programmation Le clavier est clair La LED rouge est allum e 2 Tapez A6 Un bip est mis La Led verte s allume pendant 1 seconde Tapez 0 pour supprimer les bips touches pendant la composition du code et 1 pour les autoriser Un bip est mis pour confirmer la programmation La Led verte s allume pendant 1 seconde 3 S parer le fil violet du fil noir Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement J COMMANDE EXT RIEURE BUZZER ET LED Le buzzer et les voyants rouges et
19. econd LED off The Buzzer and LED intputs are activated Centaur Mode LED off One beep is emitted Orange LED when the code is entering The Buzzer and LED intputs are activated 9 26 BIT WIEGAND FORMAT Chronograms i a 0 logic 1 1 logic DATAL 1 CLOCK DATAO i 130 2ms PR ius us Refer to the chapter Entry in programming 2ms cdvi com cdvigroup com 9 Interface The output format is 26 bit Wiegand Signals DATA1 DATAO and CLOCK Output signal in open collectors pull up of 2 2K in 5V 26 bit hexadecimal output format The frame is made of 26 bit and built as follow First parity 1 bit even parity for the first 12 bit logy Digicode Proximity reader Wiegand User Code 3 half of a byte represent the code entered Each byte is transferred from bit 7 to bit 0 Second parity 1 bit odd parity for the last 12 bit Bit 1 Bit 2 bit 25 Bit 26 Even parity on bit 2 bit13 Data 24 bits Odd parity on bit 14 bit 25 KEYPAD CODE Example with a 4 Digit keypad code 1 3 7 5 Then B 1 0000 0000 0001 0011 0111 0101 0 Decimal Parity 1 0 0 1 3 7 5 Parity 2 Hexadecimal Parity 1 0 0 0 5 5 F Parity 2 Example with a 5 Digit keypad code 7 1 3 75 Then B Decimal Parity 1 0 7 1 3 7 5 Parity 2 Hexadecimal Parity 1 0 1 1 6 C F Parity 2 Example with a 6 Digit keypad code 6 7 1 3 7
20. f the back keypad to the back plate the hole location then drill Mount the back plate plate Then mount the with the M5x8 Diax screw the 2 mounting holes and of the KCPROXWLC with the keypad on the back plate and T20 Diax spanner the hole wiring access screw on the wall hardware Controller terminal wirings ONLINE SYSTEMS _ STANDALONE KCPROXWLC WIRING TABLE cubes Wiegags format 1993 forat Seger met UR KE ET Pr ES RED 12VDC Input 12VDC Input 12VDC Input 12v 12vpc 12voc 12voc 12vbc BLACK ov ov ov Ro ov ov ov ov ov BROWN aoa command AA command a command oure GREEN DATA 0 CODE RDS cL cL WHITE DATA1 DATA RYDT DA DA BLUE CLOCK CLOCK STANDARD 1 WIRE 8 ou 18 1 PURPLE PROGRAMMING PROGRAMMING PROGRAMMING YELLOW GREEN LED GREEN LED GREEN LED ourl ORANGE RED LED RED LED RED LED Bure cdvi com cdvigroup com 3 12VDC Black OV Brown Buzzer command input Green White Data 1 Data 0 Blue Clock Programming Yellow Green LED Orange Red LED Orange Yellow White Green Blue Red Black Ocou mS brown H Purple H For the programming KCPROXWLC connect the purple cable with the black cable
21. he black cable Switch the power supply on 2 Two beeps are emitted to confirm entry in programming The keypad is illuminated The red LED is ON Note The command control of the buzzer is not possible in programming mode B ILLUMINATION DURATION 1 Enter in programming 2 Press AO to program the illumination duration One beep is emitted The Green LED is lighting up during 1 second Enter the time in seconds 10 for 10 seconds to 99 for 99 seconds or enter 00 for a permanent illumination One beep is emitted to confirm the illumination duration 3 Disconnect the purple cable with the black cable Two beeps are emitted to confirm exit from programming C OUTPUT FORMAT 1 Enter in programming 2 Press A1 to enter in the output format menu One beep is emitted Refer to the chapter Entry in programming cdvi com 8 cdvigroup com logy Digicode Proximity reader Wiegand 2 short beeps gt Entry or Exit from programming 4 short beeps gt data computing error Code Length The user code must be in 4 5 or 6 digits In decimal mode all the keypad keys can be used to program a user code except the B key In hexadecimal mode all the keypad keys can be used to program a user code except the A and B key Enter the user code and then B to validate the code The Green LED is lighting up during 1 second Press 1 to select wiegand output format
22. m MANUEL D INSTALLATION FR KCPROXWLC Lecteur double Technologie Proximit Digicode Wiegand S Programmation du mode CENTAUR ou standard ou h xad cimal 1 bip 1 bip 1 bip LED verte ON LED verte ON LED verte ON Tapez Tapez Tapez 0 mode Centaur 0 mode d cimal 0 Sans Bips touches 1 mode Standard 1 mode h xad cimal 1 Avec Bips touches 1 bip OK 1 bip OK 1 bip OK LED verte ON LED verte ON LED verte ON 4 bips Erreur 4 bips Erreur 4 bips Erreur e D connexion du c ble Violet et noir pour sortir de la programmation 2 bips sonores cdvi com cdvigroup com 19 Valeurs par d faut Tempo clairage 10 s Nombre de termes 5 Sortie Wiegand 26 bits Buzzer inactif Mode d cimal Correspondance des signaux sonores 1 bip court gt Mise sous tension et bip touche 1 bip long gt Validation d une saisie en programmation 2 bips courts gt Entr e et sortie de programmation A ENTR E EN PROGRAMMATION 1 Coupez l alimentation Reliez le fil violet au OV R tablir l alimentation 2 Deux bips sont mis pour confirmer l entr e en programmation Le clavier est clair La LED rouge est allum e B PROGRAMMATION DE L CLAIRAGE 1 Entrez en programmation Le clavier est clair La LED rouge est allum e 2 Tapez AO pour la temporisation d clairage du clavier Un bip est
23. ot exceed more than 50 meters cdvi com 2 cdvigroup com CE CE certification 43 ANCE yANDALIS al GA RESIS TO 190 26666 prox OO0OOOQO Y fs Make sure not to exceed 50 meters between the INTBUSW reader interface and the KCPROXWLC Pin Prox Digicode Make sure that the cable is not near by a high voltage cables ex 230 V AC Recommended cable 2 twisted pairs 4 wires SYT1 0 8MM Back EMF protection To secure the system from back electromagnetic fields do not forget to mount the varistor in parallel on the lock terminals Security Advice For security reasons change the factory default master code When selecting a master code and user code avoid simple codes example 3 45 6 7 Mounting recommendations Mount the keypad on a flat surface to avoid any vandalism and to insure the best mounting MANUEL D INSTALLATION EN KCPROXWLC Dual Technology Digicode Proximity reader Wiegand 3 MOUNTING KIT eel os M5x8 Diax T20 Diax Plastic screw Spanner anchor M4x30 screw 1 1 2 2 s oe gt o 99 5 0 a x 016 Lai e rt O al g f a s ss of Place the back plate on the Insert the 2 plastic anchors Insert the cable in the hole Fasten the KCPROXWLC wall then mark with a pen in the holes access area o
24. ramming F PROGRAMMING CENTAUR OR STANDARD MODE 2 Press A6 One beep is emitted The Green LED is lighting up during 1 second Press 0 to disable the audible signal 1 Enter in programming 2 Press A4 to select the mode One beep is emitted Press 1 to enable the audible signal The Green LED is lighting up during 1 second One beep is emitted to confirm programming Press 0 for a Centaur mode or press 1 The Green LED is lighting up during 1 second for a Standard mode One beep is emitted to confirm programming 3 Disconnect the purple cable with the black cable The Green LED is lighting up during 1 second Two beeps are emitted to confirm exit from programming 3 Disconnect the purple cable with the black cable Two beeps are emitted to confirm exit I EXTERNAL CONTROL OF THE LED amp BUZZER from programming The buzzer can be activated from an external input G DECIMAL OR HEXADECIMAL MODE The control is done with a logic signal on the input Decimal or hexadecimal mode affects only the pin code output format Buzzer LED Off Buzzer LED On Buzzer LED Off OV 1 Enter in programming mode ne e 2 Press A5 to enter in the mode setting menu One beep is emitted The Green LED is lighting up during 1 second Press 0 for a decimal mode press 1 for a hexadecimal mode One beep is emitted to confirm programming Standard Mode The Green LED is lighting up during 1 s
25. rity 2 Parity 1 0 if the number of 1 in bit 2 to bit 15 is even 1 if the number of 1 in bit 2 to bit 15 is odd Parity 2 lt 0 if the number of 1 in bit 16 to bit 29 is odd 1 if the number of 1 in bit 16 to bit 29 is even 11 44 BIT WIEGAND FORMAT 44 bit hexadecimal format The output format from the proximity reader is 44 bit Signal and CLOCK and is structured as fol Data 10 digit code number hexadecimal MSByte first Each hexadecimal digit 4 bit MSBit first LRC 4 bit or restricted in between the digit of the data MSBit first ow Bit 1 to bit 40 Bit 41 to bit 44 Badge code LRC KEYEAD T PADGEE CODES Example Badge 0F01198AAD 6 DIGIT Keypad code 6 7 1 3785 Then B DATA1 DATAO 0000 1111 cdvi com cdvigroup com 11 logy Digicode Proximity reader Wiegand 12 PROPRIETARY FORMAT OWNED BY STANDARD This format is compatible with other Standard products Contact us 13 ISO 7811 TRACK 2 FORMAT ss Characters ES LRC SS start sentinel gt Hex B ES end sentinel gt Hex F LRC Ou Exclusif de tous les caract res de la trame including SS and ES The code length is set at 8 digits In 4 digits gt 00001234 In 5 digits gt 00012345 In 6 digits gt 00123456 Pr sence Data
26. tant le code du badge Chaque mot est transmis bit de poids fort en premier Parit 2 1 bit parit impaire des 14 derniers bits Bit 1 Bit 2 bit 29 Bit 30 Parit paire sur bit 2 bit 15 Donn e 28 bits Parit impaire sur bit 16 bit 29 CODES CLAVIER F BADGE Exemple Badge OF01198AAD Code clavier 6 termes 6 7 1 3 7 5 puis x B gt 1 0001 0001 1001 1000 1010 1010 1101 0 Parit 1 1 1 9 8 A A D Parit 2 CODE D cimal Parit 1 0 6 7 1 3 7 5 Parit 2 US Hexad cimal Parit 1 0 0 A 3 E 8 F Parit 2 Parit 1 0 si le nombre de 1 dans bit 2 bit 15 est paire 1 si le nombre de 1 dans bit 2 bit 15 est impaire Parit 2 0 si le nombre de 1 dans bit 16 bit 29 est impaire 1 si le nombre de 1 dans bit 16 bit 29 est paire 11 FORMAT DE SORTIE WIEGAND 44 BITS Structure et description du message Format 44 bits hexad cimal La communication s effectue par une liaison de type Wiegand 44 bits Signaux DATA1 DATAO et CLOCK La trame est constitu e d une totalit de 30 bits et se d compose comme suit Bit 1 bit 40 Bit 41 bit 44 Code badge LRC cdvi com cdvigroup com 23 uble Technologie Proximit Digicode Wiegand CODES CLAVIER F BADGE Exemple Badge OF01198AAD code clavier 6 termes 6 7 1 3 7 5 puis B gt 0000
27. verts du clavier peuvent tre command s ext rieurement Il suffit d appliquer un signal logique sur les entr es correspondantes fils marron orange et jaune Buzzer LED inactif Buzzer LED actif Buzzer LED inactif Mode Ce nta Wants teints Un bip court l envoi du code et voyant orange Les entr es voyant et buzzer sont actives Mode Standard Voyants teints Les entr es voyant et buzzer sont actives R f rez vous la proc dure d entr e en programmation en d but de chapitre cdvi com cdvigroup com 21 ble Technologie Proximit Digicode Wiegand 9 FORMAT DE SORTIE WIEGAND 26 BITS Chronogrammes 0 logique i 1 logique DATA1 CLOCK LI DATAO C a a 150 Sme 150 Interfa age Hs us La communication s effectue par une liaison de type Wiegand 26 bits Format 26 bits hexad cimal Signaux DATA1 DATAO et CLOCK Sortie des signaux en collecteur ouvert avec pulls up interne de 2 2K au 5V La trame est constitu e d une totalit de 26 bits et se d compose comme suit 1 e parit 1 bit parit paire des 12 bits suivants Code clavier 3 mots d un octet repr sentant le code tap Chaque mot est transmis bit de poids fort en premier 2 me parit 1 bit parit impaire des 12 bits pr c dents 2ms Bit 1 Bit 2 bit 25 Bit 26 Parit paire sur bit 2 bit13 Donn e 24 bits Parit impaire sur bit 14 bit 25
28. z en programmation Le clavier est clair La LED rouge est allum e 2 Tapez A2 pour la saisie du nombre de termes des codes Un bip est mis La LED verte s allume 1 seconde Tapez 4 5 ou 6 pour le nombre de termes Un bip est mis pour confirmer la programmation La LED verte s allume 1 seconde 3 S parer le fil violet du fil noir Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement E PROGRAMMATION DU NOMBRE DE BITS 1 Entrez en programmation Le clavier est clair La LED rouge est allum e 2 Tapez A3 pour la saisie du nombre de bits du code Wiegand R f rez vous la proc dure d entr e en programmation en d but de chapitre cdvi com 20 cdvigroup com MANUEL D INSTALLATION KCPROXWLC Lecteur double Technologie Proximit Digicode Wiegand Un bip est mis J La Led verte s allume pendant 1 seconde A3 Tapez 26 30 ou 44 pour d finir le nombre de bits en mode Wiegand Un bip est mis pour confirmer la programmation La Led verte s allume pendant 1 seconde 3 S parer le fil violet du fil noir Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement F PROGRAMMATION DU MODE CENTAUR OU STANDARD 1 Entrez en programmation Le clavier est clair La LED rouge est allum e 2 Tapez A4 pour la saisie du mode Un bip est mis La Led verte s allume pendant 1 se