Home
Maytag Refrigerator Rework Updates Revision to Instruction Sheet
Contents
1. Remove all electrical components from compressor pull Straight off the compressor Disconnect from wire harness 6 Install new overload on bottom compressor pin See Figure 3 Figure 3 7 Install start device on top two 2 compressor terminal pins Make sure the start device and overload are securely mounted on the compressor terminal pins See Figure 3 8 Install new jumper wire on left terminal terminal number 2 on start device See Figure 4 Figure 4 Reinstall wire harness to the correct terminals as shown in wiring schematic See Figures 4 and 5 Always refer to the diagram shipped with the product when performing any repair e Plug white jumper wire into 3 16 terminal on old harness e Plug blue wire into overload on bottom terminal e Plug white wire into start device terminal number 3 e Reattach green yellow wire to compressor ground RUN CAP O FC PTC RELAY WH JUMPER WIRE GN YL Cu CO OVERLOAD Tu L1 Figure 5 Whirlpool Corporation 2009 All Rights Reserved 10 Install new terminal cover Be sure to insert the group of wires including the entire jumper into the provided slot on the terminal cover Engage the bottom of the cover first and then push the cover upward while snapping in place See Figure 6 11 12 13 14 15 16 Figure 6 With a dry cloth clean area where identification sticker green dot will be located The green dot supplied
2. in the service kit must be located next to the model serial number tag See Figure 1 The supplied Consumer Information Leave Behind must be left with the customer as it provides important information about the repair Reinstall the machine compartment cover and mounting screws Replace refrigerator in its original location Plug in refrigerator or reconnect power Record all customer information including model number serial number and the date of purchase of the refrigerator being serviced Report all information back to Whirlpool through the service claim process using R22553 in the authorization field on your work order and submit for labor payment Do not list part on the claim as it has been provided for repair at no charge W10247582 Rev B Fiche d instructions Proc dure de remplacement du dispositif de surcharge d marrage A AVERTISSEMENT Risque de choc lectrique D connecter la source de courant lectrique avant l entretien Replacer pi ces et panneaux avant de faire la remise en marche Le non respect de ces instructions peut causer un d c s ou un choc lectrique IMPORTANT Pour les compresseurs EGY100 et EGZ100 utiliser le protecteur de surcharge 445NFBYY 61006296 Pour le compresseur EGU70 utiliser le protecteur de surcharge 427NFBYY 61006294 REMARQUE V rifier que le r frig rateur n a pas t modernis auparavant Une vignette d identification point vert proc
3. Date To Subject March 12 2009 Service Providers Maytag Refrigerator Rework Updates Revision to Instruction Sheet Service Instruction Sheet Revision An incorrect wiring diagram was included in the Service Instruction Sheet W10247582 with repair kit part W10247581 A corrected Service Instruction Sheet W10247582 revision B is attached Wiring diagram Figure 5 has been replaced and Step 9 has been revised All rework repairs should reference the attached corrected Service Instruction Sheet Service Instruction Sheets included in existing parts kits inventory at Whirlpool Parts Distributors are incorrect Corrected Instruction Sheets will be included in future parts kits assembled for shipment to Parts Distributors Copies of the revised Instruction Sheet have also been posted on ServiceMatters and ServiceBench websites Please call the Tech Line at 1 800 832 7174 if you have any questions about this revision Maytag Refrigerator Repair Kits and local Whirlpool Parts Distributors Whirlpool Parts Distributors have been instructed to supply repair kits to authorized service companies only on an as needed basis Please order repair kits as needed to ensure adequate inventory availability Instruction Sheet For Overload Start Device Replacement Procedure AWARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electri
4. a la mise la terre du compresseur RUN CAP A3 o PTC RELAY OR WH or WH O OR N CAVALIER AL GN YL OVERLOAD in L1 Figure 5 Whirlpool Corporation 2009 Tous droits r serv s 10 Installer le nouveau couvercle du terminal Veiller ins rer le groupe de fils incluant le cavalier entier dans la fente pr vue sur le couvercle du terminal Engager d abord le bas du couvercle puis pousser le couvercle vers le haut en l emboitant en place voir la figure 6 Figure 6 11 Avec un chiffon sec nettoyer la r gion o la vignette d identification point vert sera situ e Le point vert fourni avec l ensemble de service doit tre situ pres de la plaque du num ro de s rie mod le de l unit voir la figure 1 12 L Information remettre au consommateur fournie doit tre laiss e au client puisqu elle donne de l information importante sur la r paration 13 R installer le couvercle du compartiment machinerie et la vis de montage 14 Replacer le r frig rateur son emplacement d origine 15 Brancher le r frig rateur ou reconnecter la source de courant lectrique 16 Enregistrer toute l information du client incluant le num ro de mod le le num ro de s rie et la date d achat du r frig rateur de ce service Rapporter toute l information a Whirlpool via le processus de r clamation de service en utilisant R22553 dans la case d autorisation sur votre bon de travai
5. cal shock IMPORTANT For Compressors EGY100 and EGZ100 use overload 445NFBYY 61006296 For Compressor EGU70 use overload 427NFBYY 61006294 NOTE Verify that the refrigerator has not been previously reworked An identification sticker green dot next to the unit s model serial number tag indicates the overload and start device have already been upgraded See Figure 1 Figure 1 1 Unplug refrigerator or disconnect power NOTE Make sure to protect floor from any damage when pulling refrigerator out 2 Pull refrigerator out to expose machine compartment cover on back of refrigerator 3 Remove the screws holding the machine compartment cover in place Remove the machine compartment cover to expose the compressor Set the screws and cover aside for reuse later NOTE This service kit is an approved replacement for only Embraco compressor types EGY100 EGZ100 and EGU70 Verify refrigerator has one of these compressors See Figure 2 If not go to step 13 kit parts will not work with Tecumseh or other compressors Refer to service manual for Tecumseh specific parts FOR GZ A he re enn 15 127V Gi r Wi KE LT Figure 2 LS ir 4 ai F1 Kit Contains 1 Start Device 2 Overload 1 Identification Sticker green doi 1 Wire Jumper 1 Terminal Cover 1 Consumer Information Leave Behind 1 Instruction Sheet 4 Remove terminal cover if equipped from compressor 5
6. formation a remettre au consommateur Fiche d instructions 1 2 1 1 1 1 1 Enlever le terminal lectrique si pr sent du compresseur Enlever tous les composants lectriques du compresseur en tirant tout droit pour les s parer du compresseur D connecter du faisceau de c blage Installer le nouveau protecteur de surcharge sur la broche inf rieure du compresseur voir la figure 3 Figure 3 Installer le dispositif de d marrage sur les deux 2 broches du terminal sup rieur sur le compresseur S assurer que le dispositif de d marrage et le protecteur de surcharge sont mont s solidement sur les broches du terminal sur le compresseur voir la figure 3 Installer le nouveau cavalier sur le terminal de gauche terminal num ro 2 sur le dispositif de d marrage voir la figure 4 MSE LA TERRE DU COMPRESSEUR TERMINAL INF RIEUR secs SUR LE PROTECTEUR Des DE SURCHARGE Figure 4 9 Reinstaller le faisceau de cablage aux bons terminaux tels qu illustr s sur le schema de c blage voir les figures 4 et 5 Toujours se reporter au diagramme livr avec le produit lors d une intervention de r paration e Brancher le cavalier blanc dans le terminal de 3 16 sur le vieux faisceau e Brancher le fil bleu dans le protecteur de surcharge sur le terminal inf rieur e Brancher le fil blanc dans le dispositif de d marrage terminal num ro 3 e Rebrancher le fil vert jaune
7. he de la plaque du num ro de s rie mod le de l unit indique que le dispositif de surcharge et de d marrage ont d j t mis niveau voir la figure 1 DU NUM RO DE SERIE MODELE DE L UNITE 3 mas sws 7 20 RIMA 4 50 Pe mec nema 115V 60HZ nea ane 1U en D Figure 1 1 D brancher le r frig rateur ou d connecter la source de courant lectrique REMARQUE Veiller prot ger le sol de tout dommage lors du d placement du r frig rateur 2 Sortir le r frig rateur pour exposer le couvercle du compartiment machinerie l arri re du r frig rateur 3 Enlever les vis retenant en place le couvercle du compartiment machinerie Enlever le couvercle du compartiment machinerie pour exposer le compresseur Mettre le couvercle et les vis de c t pour usage ult rieur REMARQUE Cet ensemble de service est un remplacement approuv seulement pour les types de compresseurs Embraco EGY100 EGZ100 et EGU70 V rifier que le r frig rateur est muni de lun de ces compresseurs voir la figure 2 Sinon passer l tape 13 les pi ces de l ensemble ne fonctionneront pas pour les compresseurs Tecumseh ou autre Se r f rer au manuel d entretien pour les pi ces sp cifiques Tecumseh eee EGZ MAL Pi h 127V 0 Fr 5 127 Te Figure 2 L ensemble contient Dispositif de d marrage Protecteur de surcharge Vignette d identification point vert Fil cavalier Terminal Couvercle In
8. l et le soumettre pour le paiement de main d uvre Ne pas indiquer la pi ce sur la r clamation puisqu elle a t fournie sans frais pour la r paration W10247582 Rev B