Home
InDip 550 - Whaley Food Service
Contents
1. O rings Replace any damaged seals and housing components immediately InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 5 4 1 Before starting up always check the measuring system Inspect the housing sensor assembly and check for leaks from housing and apparatus If ever in doubt consult your supplier Description of product and materials The insertion housings InDip 550 serve as enclosures for METTLER TOLEDO sensors used for pH redox and dissolved oxygen conductivity and turbidity measurements particularly in industrial waste water All parts of the housing in contact with the process wetted parts are made of PVC or PVDF according to order specification O rings in contact with the process medium are made of Viton The solution grounding pin is made of stainless steel 1 4435 PVC type or Hastelloy C 22 PVDF type Installation and start up procedures The housing is delivered completely assembled To fit the sensor and fo install the housing proceed as follows Fitting the sensor into the housing When installing 12 mm sensors with Pg13 5 ensure that the white Teflon was her is positioned directly beneath the 12 mm sensor head with the tapered chamfered face pointing downwards Then follows the O ring Pull the sensor holder out of the tube with out any turning movement if necessary with the aid of a screwdriver inserted be tween tube and senso
2. 13 5 P Pg 13 5 6P IND 06 04 Mettler Toledo GmbH InDip 550 Printed in Switzerland 52 400 739 10 InDip 550 InDip 550 Bedienungsanleitung Inhaltsverzeichnis Seite 1 Einleitung 11 1 1 Vereinbarung 11 2 Wichtige Hinweise 11 2 1 Allgemeines 11 2 2 Sicherheitshinweise 11 3 Produkte und Materialbeschreibung 12 4 Installation und Inbetriebnahme 12 4 1 Einbau des Sensors in die Armatur 12 4 2 Einbau der Armatur 13 4 3 Pr fen der korrekten Installation 14 4 4 Verbindung zwischen Potentialaus gleich und Transmitter 14 D Wartung ans ae 14 6 Produktspezifikation 14 6 1 Lieferumfang 14 6 2 Technische Spezifikationen 15 7 Zubeh r 15 8 Garantiebestimmungen 15 9 Masszeichnungen der Armatur 16 InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 11 1 1 Einleitung Diese Befriebsanleitung beschreibt die Handhabung der Einbauarmatur InDip 550 Die Armaturen sind gepr fte technisch hochwertige Produkte und entsprechen dem Stand der Technik Ein fehlerhafter Umgang kann dennoch gef hrlich sein Vereinbarung Dieses Piktogramm kennzeichnet Sicherheits und Gefahrenhinweise deren Missachtung zu Personen 2 1 2 2 und oder Sachsch den f hren kann Wichtige Hinweis
3. Type InDip 550 Operating instructions 6 2 Technical specification Temp range 0 60 C PVC 0 100 C PVDF Pressure range ambient Material Wetted parts made of PVC or PVDF according to order specification Seals made of Viton Solution grounding pin SS 1 4435 PVC HAC 22 PVDF Type standard and GP Dimensions see chapter 9 06 04 Printed in For further details on sensors see sensor data sheets or ask the supplier of your housing Mettler Toledo GmbH InDip 550 Switzerland 52 400 739 8 InDip 550 1 Accessories Articles Order No Set of replacement parts O rings Viton 52 400 319 1 piece 40 95 x 2 62 1 piece 36 17 x 2 62 1 piece 10 77 x 2 62 Sensor holder Pg13 5 PVC 52 400 622 Sensor holder Pg13 5 PVDF 52 400 623 Sensor holder Pg13 5 PVC with protective cage with solution grounding type GP 52 401 332 Sensor holder Pg13 5 PVC with protective cage no solution grounding type P 52 401 334 Sensor holder Pg13 5 PVDF with protective cage with solution grounding type GP 52 401 333 Sensor holder Pg13 5 PVDF with protective cage no solution grounding type P 52 401 335 Sensor holder for inductive conductivity sensors PVC 52 401 956 Sensor holder for inductive conductivity sensors PVDF 52 401 957 Sensor holder NPT1 PVC 52 400 626 Sensor holder NPT1 PVDF 52 400 627 Sensor holder NPT1 Cond PVC 52 402 872
4. aux el angeschlossen Wartung Elektrode Sensor Armatur und Dichtungen m ssen in sauberem Zustand gehalten werden Ersetzen Sie allf llig besch digte Dichtungen oder Bestandteile sofort Angaben ber den Unterhalt von Elektroden und Sensoren sind in den dazugeh rigen Bedienungsanleitungen enthalten Wichtig Vor dem Einbau der Armatur m ssen unbedingt alle O Ringe gereinigt und gefettet werden Wichtig Das periodische Ersetzen aller O Ringe wird empfohlen 6 Produkispezifikation 6 1 Lieferumfang Die Standardlieferung einer Armatur besteht aus folgenden Teilen Armatur InDip 550 Bedienungsanleitung InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 15 6 2 Technische Spezifikationen Temp bereich 0 60 C PVC 0 100 C PVDF Druckbereich drucklos Material Mediumber hrte Teile aus PVC oder PVDF Dichtungen aus Viton Potentialausgleich Stift aus SS 1 4435 PVC oder Hastelloy C 22 PVDF Standard und GP Abmessungen siehe Kapitel 9 F r n here Angaben ber Elektroden und Sensoren beachten Sie bitte die entspre chenden Datenbl tter oder wenden Sie sich an Ihren Armatur Lieferanten 7 Zubeh r Bezeichnung Bestellnumer Ersatz Set O Ringe 52 400 319 Elektrodenhalter Pg13 5 PVC 52 400 622 Elektrodenhalter Pg13 5 PVDF 52 400 623 Elektrodenhalter Pg13 5 PVC mit Schutz korb mit Potentialausgleich Typ GP 52 401 3
5. ignored could result in injuries to personnel 2 1 2 2 and or in material damage Important notes General Immediately on receipt check that the hou sing is complete and in good condition Notify your supplier of any damage or deficiency Please also refer to your supplier for further information on the ordering of spare parts and accessories Safety precautions Safety and hazard warnings could if ignored result in injuries to personnel and or material damage Important Work on the housing should be assigned only to trained per sonnel Observe local regulations concerning the safety of people and property Be sure to read and follow the instructions in this operating manual carefully InDip 550 housings are designed to con tain only METTLER TOLEDO sensors Any other kind of use could be dangerous and is not permitted The materials used for the housing are described in Section 3 Description of product and materials Make sure the materials are suitable for the selected application To ensure that the housing is correctly installed and maintained follow the instructions given in this manual Incorrect handling of the housing can result in a broken sensor and leakage Before doing anything to the installed housing ensure that the process facility is in a safe condition release pressure empty rinse vent purge etc Use only clean sensors housings and
6. 12 4 1 InDip 550 Bringen Sie die Prozessanlage in einen gefahrlosen Zustand bevor Sie an der Armatur manipulieren Druck entfernen entleeren sp len entl ften ventilieren USW Verwenden Sie nur gereinigte Elektroden Sensoren Armaturen und Stutzen Er setzen Sie besch digte Dichtungen und Einzelteile der Armatur sofort berpr fen Sie vor jeder Inbetriebnahme das Messsystem berpr fen Sie dabei die Messkette und die Dichtheit von Armatur und Anlage Wenden Sie sich bei Unklarheiten an Ihren Lieferanten Produkte und Material beschreibung Die Armaturen dienen als Halterung f r METTLER TOLEDO Elektroden und Sensoren zur Messung von pH Redox gel stem Sauerstoff Leitf higkeit und Tr bung vor allem im industriellen Abwasser Die Armaturen sch tzen Elektroden Sensoren vor mechanischer Besch digung Die Steck verbindung erm glicht einen einfachen Elektroden Sensorwechsel Alle mit dem Prozess in Ber hrung kom menden Teile der Armatur sind aus PVC oder PVDF je nach Ihrer Bestellung Die mit dem Prozess in Ber hrung kommende O Ringe sind aus Viton Der Potentialausgleichstift ist aus rostfreiem Stahl 1 4435 PVC Typen oder Hastelloy C 22 PVDF Typen Installation und Inbetriebnahme Eine Armatur wird als komplette zusam mengebaute Einheit geliefert Um die Elek trode oder den Sensor in die Armatur einzu bauen gehen Sie wie folgt vor Einbau der Elektrode oder de
7. 22 Gardntie EEN er 22 Dimensions du support 23 06 04 Mettler Toledo GmbH InDip 550 Printed in Switzerland 52 400 739 18 1 1 InDip 550 Introduction Ce manuel d instruction d crit comment utiliser les supports InDip 550 Ces supports sont des produits de pointe d une grande qualit de conception test s par METTLER TOLEDO Une mauvaise manipulation pourrait n an moins tre dangereuse Conventions Ce pictogramme repr sente les aver tissements de s curit et de danger qui sont susceptibles d occasionner des 2 1 2 2 dommages corporels au personnel et ou des dommages ma riels s ils sont ignor s Notes importantes G n ralit s D s sa r ception v rifier que le support est complet et en bon tat Avertir votre fournisseur de tout dommage ou d faut Veuillez aussi vous r f rer votre fournisseur pour de plus amples informations sur la commande de pi ces de rechange et d accessoires Mesures de s curit Les avertissements de s curit et de danger sont susceptibles d occasionner des dom mages corporels au personnel et ou des dommages mat riels s ils sont ignor s Important Les t ches effectuer sur le Support doivent tre uniquement confi es du personnel qualifi Respecter les r glementations locales en mati re de s curit des personnes et des biens Bien lire et suivre scrupuleusement les in structions contenues dans ce
8. 32 Elektrodenhalter Pg13 5 PVC mit Schutz korb ohne Potentialausgleich Typ P 52 401 334 Elektrodenhalter Pg13 5 PVDF mit Schutz korb mit Potentialausgleich Typ GP 52 401 333 Elektrodenhalter Pg13 5 PVDF mit Schutz korb ohne Potentialausgleich Typ P 52 401 335 Elektrodenhalter f r induktive Leitf higkeitssensoren PVC 52 401 956 Elektrodenhalter f r induktive Leitf higkeitssensoren PVDF 52 401 957 Elektrodenhalter NPT1 PVC 52 400 626 Elektrodenhalter NPT1 PVDF 52 400 627 Elektrodenhalter NPT1 Cond PVC 52 402 872 Elektrodenhalter NPT3 4 PVC 52 400 624 Elektrodenhalter NPT3 4 PVDF 52 400 625 Kabelverschraubung Tr bung 52 400 785 Befestigungs Set 52 400 775 Loser Flansch DN40 PVC 52 400 309 Loser Flansch DN40 PVDF 52 400 774 8 Garantiebestimmungen Die Armaturen sind technisch hochwertig und verl sslich Sie werden laufend dem neuesten Stand der Technik angepasst und verlassen unsere Produktionsst tten erst nach eingehender Endkontrolle Die Garantie umfasst vom Datum der Auslieferung an gerechnet alle innerhalb eines Jahres auftretenden M ngel die ihre Ursache in Material oder Produktionsfehlern haben 06 04 Mettler Toledo GmbH InDip 550 Printed in Switzerland 52 400 739 16 Pg 13 5 3 4 NP 1 NPT Cond InDip 550 Normale Abnutzungserscheinungen oder Sch den aufgrund unsachgem ssem Ein satz wie chemische Unverfr glichkeit etc
9. 50 InDip5 50 InDip 5 2 InDip 550 English Page 3 Deutsch Seite 10 Francais Page 17 InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 3 InDip 550 Instruction manual Contents Page 1 Introduction 4 1 1 Conventions 4 2 Important notes 4 2 1 Gener le 4 2 2 Safety precautions 4 3 Description of product and materials 5 4 Installation and start up procedures 5 4 1 Fitting the sensor into the housing 5 4 2 Installation of the housing 6 4 3 Checking for correct installation 7 4 4 Connection of the grounding to the transmitter 7 5 Maintenance 7 6 Product specification 7 6 1 Supply 7 6 2 Technical specification 7 7 Accessories 8 8 Warranty 8 9 Housing dimensions 9 Printed in Switzerland 52 400 739 1 1 InDip 550 Introduction These operating instructions describe how to use the housings InDip 550 These housings are state of the art high grade engineered products tested by METTLER TOLEDO Nevertheless improper handling could be dangerous Conventions This pictogram represents safety and hazard warnings which if
10. Dichtungsfl chen und Dichtungen in sauberem Zustand halten Wichtig Kabelverschraubung zuerst abschrauben vor dem Herausziehen des E halters aus dem Rohr 4 2 Der Ausbau der Elektode des Sensors erfolgt in umgekehrter Reihenfolge Installation der Armatur Die InDip 550 Armaturen k nnen mittels eines Befestigungssets an der Wand des Kanals oder des Beckens befestigt werden Details entnehmen Sie der Bedienungs anleitung des Befestigungssets Es empfiehlt sich die Armatur so zu installieren dass eine Selbstreinigung m glich ist Str mungs richtung beachten AN Pg 13 5 3 4 NPT 1 NPT Cond 1 NPT 06 04 Mettler Toledo GmbH InDip 550 Printed in Switzerland 52 400 739 14 4 3 Pg 13 5 P Pg 13 5 GP IND Pr fen der korrekten Installation Wichtig berpr fen Sie vor jeder Inbetriebnahme das Messsystem berpr fen Sie dabei die Messkette 4 4 und die Dichtheit von Armatur und Anlage Beginnen Sie mit der Inbetriebnahme erst nachdem die Kontrolle des Messsystems erfolgt ist und die M ngel behoben wurden Verbindung zwischen Potential ausgleich und Transmitter Die Verbindung erfolgt am InDip mit einem vergoldeten 4 mm Bananenstecker Das Kabel wird an der Transmitter Klemmenleiste bei der Bezeichnung
11. InDip 550 Printed in Switzerland 52 400 739 22 InDip 550 6 Sp cifications du produit 6 1 Fourniture Une livraison standard se compose des l ments suivants Support de Type InDip 550 Manuel d instructions 6 2 Sp cifications techniques Domaine de 0 60 C PVC temperature 0 100 C PVDF Domaine de ambiente pression Mat riaux Toutes les parties en contact avec le milieu sont en PVC ou PVDF selon le produit livr Les joints sont en Viton Contact de masse liquide en acier inox 1 4435 type PVC ou Hastelloy C 22 type PVDF Dimensions se reporter la fiche technique du produit 7 Pi ces de rechange et accessoires D signation No de commande Kit de pi ces de rechange joints toriques 52 400 319 Adaptateur Pg13 5 PVC 52 400 622 Adaptateur Pg13 5 PVDF 52 400 623 Adaptateur Pg13 5 PVC avec cage de protection avec masse liquide Type GP 52 401 332 Adaptateur Pg13 5 PVC avec cage de protection sans masse liquide Type P 52401 334 Adaptateur Pg13 5 PVDF avec cage de protection avec masse liquide Type GP 52 401 333 Adaptateur Pg13 5 PVDF avec cage de protection sans masse liquide Type P 52401 335 Adapteur pour les capteurs inductifs PVC 52 401 956 Adapteur pour les capteurs inductifs PVDF 52 401 957 Adapteur NPT1 PVC 52 400 626 Adapteur NPT1 PVDF 52 400 627 Adapteur NPT3 4 PVC 52 400 624 Adapteur NPT1 Co
12. R se 2 IE 2 Ss 3 2 SRE ER MEER 5 o See gt 2 Gi SE E ss e x BSS o Ss gt E Z E is CS E S X SS 30 30 EL T HH Pg 13 5 3 4 NP 1 NPT Cond 1 NPT 06 04 Mettler Toledo GmbH InDip 550 Printed in Switzerland 52 400 739 CH USA Mettler Toledo Ind e Com Ltda Alameda Araguaia 451 Alphaville 06455 000 Barueri SP Brazil Phone 55 11 4166 74 00 Fax 55 11 4166 74 01 Mettler Toldeo Schweiz AG Im Langacher P O Box 8606 Greifensee Switzerland Phone 41 44 944 45 45 Fax 41 44 944 45 10 Mettler Toledo GmbH Proze analytik Ockerweg 3 35396 Gie en Germany Phone 49 641 507 333 Fax 49 641 507 397 Mettler Toledo Analyse Industrielle S rl 30 Boulevard de Douaumont BP 949 75829 Paris Cedex 17 France Phone 33 1 47 37 06 00 Fax 33 1 47 37 46 26 Mettler Toledo Ingold Inc 36 Middlesex Turnpike Bedford MA 01730 USA Phone 1 781 301 8800 Toll free 1 800 352 8763 Fax 1 781 271 0681 Mettler Toledo GmbH Process Analytics Industrie Nord CH 8902 Urdorf Phone 41 44 729 62 11 Fax 41 44 729 66 36 www mtpro com Subject to technical changes Mettler Toledo GmbH 01 06 Printed in Switzerland 52 400 739
13. Sensor holder NPT3 4 PVC 52 400 624 Sensor holder NPT3 4 PVDF 52 400 625 Cable gland turbidity 52 400 785 Tube clamp 50 mm PE 52 400 775 Separate flange DN 40 PVC 52 400 309 Separate flange DN40 PVDF 52 400 744 8 Warranty The housings are of high technical quality and are subject to a policy of continuous design review to incorporate the latest advances Their reliability is ensured by a thorough final inspection prior to leaving our factory The warranty is valid for one year from the date of delivery and covers any defects due to faulty materials or manufacture Not covered by the warranty are normal wear and tear and any damage caused by improper use e g chemical incompatibility of the materials etc The warranty extends only to replacement or repair of deficient products at our discretion The warranty is void if the customer or others modify in any way the products supplied by us Defects must be reported to the supplier immediately upon discovery and under all circumstances within the warranty period InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 9 9 Housing dimensions g85 50 30 A ii Pg 13 5 3 4 NP 1 NPT Cond 1 NPT Pg
14. a position that self cleaning is achieved note the direction of flow Figure 1 fn Pg 13 5 Cen f e Pg 13 5 3 4 NP 1 NPT Cond AN tb Pg 13 5 P Pg 13 5 GP IND InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 7 4 3 Checking for correct installation Important Each time before starting up check the measuring system inspect the sensor assembly and examine for leaks from housing and 4 4 apparatus Do not begin operation until the measuring system has been checked and any neces sary corrective action has been taken Connection of the grounding to the transmitter Use a gold plated 4 mm banana plug to connect the solution grounding to the transmitter Connect your grounding cable to the position aux el of the terminal of the transmitter Maintenance The sensor housing and sealings must be kept clean Replace any damaged seals or components immediately Details on maintenance of the sensor are contained in the sensor operating instruc tions Attention Before mounting the hou sing it is imperative to clean and grease the O rings with anti seize Important It is advisable that all O rings are replaced periodically 6 Product specification 6 1 Supply A standard delivery comprises the following items Housing
15. e Allgemeines berpr fen Sie die Armatur nach Erhalt sofort auf Vollst ndigkeit und einwandfreien Zustand Melden Sie allf llige Sch den oder Unvoll st ndigkeit Ihrem Lieferanten F r weitere Ausk nfte betreffend Bestellun gen von Ersatzteilen und Zubeh r wenden Sie sich bitte ebenfalls an Ihren Lieferanten Sicherheitshinweise Die Missachtung von Sicherheits und Gefahrenhinweisen kann zu Personen und oder Sachsch den f hren Wichtig bertragen Sie Arbeiten an den Armaturen nur qualifiziertem Personal Beachten Sie alle lokalen Vorschriften betreffend der Sicherheit von Personen und Sachen Sorgen Sie daf r dass die Instruktionen dieser Bedienungsanleitung gelesen und eingehalten werden Die Armaturen dienen ausschliesslich zum Einbau von durch METTLER TOLEDO spezifizieren Elektroden und Sensoren Ein anderweitiger Einsatz kann gef hrlich sein und ist nicht zul ssig Achten Sie beim Einsatz der Armatur da rauf dass diese bez glich Material best ndigkeit den Anforderungen des Prozesses gen gt siehe Kapitel 3 Pro dukte und Materialbeschreibung Folgen Sie betreffend des korrekten Ein baus der Armatur der Handhabung und der Unterhaltsarbeit den Anweisungen Fehlmanipulationen an der Armatur k nnen zum Bruch der Elekirode des Sensors und zu einer Leckage der Armatur f hren 06 04 Mettler Toledo GmbH InDip 550 Printed in Switzerland 52 400 739
16. est conseill de placer le support de mani re favoriser un nettoyage auto matique des sondes c est dire si possible contre le sens du flot Figure 1 FN Pg 13 5 InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 21 KR 3 4 NP 1 NPT Cond 1 NPT Pg 13 5 P Pg 13 5 GP IND 4 3 V rification de l installation Important V rifier le sysi me de mesure examiner l lectrode ou la sonde et rechercher d ventuelles fuites avant chaque mise en marche Ne pas commencer l utilisation avant que le syst me de mesure n ait t v rifi et que toute mesure corrective n ait t prise 4 4 Connexion du c ble de masse liquide Utiliser une fiche banane plaqu e or de 4 mm pour connecter votre c ble au support Le c ble doit tre connect la po sition aux el du bornier du transmetteur 5 Entretien L lectrode ou la sonde le support et le manchon doivent tre gard s propres Rem placer imm diatement tout joint ou compo sant endommag Important avant le montage du support v rifier que les joints toriques soient nettoy s et graiss s Il est recommand de remplacer r guli re ment tous les joints toriques 06 04 Mettler Toledo GmbH
17. fallen nicht unter Garantieleistungen Unse re Garantieleistung beschr nkt sich nach unserer Vahl auf Ersatz oder Reparatur der mangelhaften Produkte Die Garantie erlischt wenn der Kunde oder Dritte an den von uns gelieferten Produkten nderungen vornehmen M ngel sind unmittelbar nach der Feststel lung in jedem Fall innerhalb der Garantie frist dem Lieferanten mitzuteilen Masszeichnungen der Armatur G50 950 SC OS Pg 13 5 P Pg 13 5 GP IND InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 17 InDip 550 Manuel d instruction Table des matieres Page 1 Introduction 18 1 1 Conventions 18 2 Notes importantes 18 2 1 G n ralit s 18 2 2 Mesures de s curit 18 Description du produit et des mat riaux 19 4 Proc dures d installation et de mise en marche 19 4 1 Installation du capteur dans le support 19 4 2 Installation du support 20 4 3 V rification de l installation 21 4 4 Connexion du c ble de masse liquide 21 GR OC 21 6 Sp cifications 22 6 1 Fourniture 22 6 2 Sp cifications techniques 22 Ts JACCESSOINRS En er EE EA
18. nd PVC 52 402 872 Adapteur NPT3 4 PVDF 52 400 625 Presse toupe turbidit 52 400 785 Set de fixation pour canal et r servoir sur demande Bride de fixation DN40 PVC 52 400 309 Bride de fixation DN40 PVDF 52 400 774 8 Garantie Les supports sont d une grande qualit technique et font l objet d une politique de r vision continuelle afin de prendre en compte les plus r cents progr s Leur fiabilit est assur e par une minutieuse InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 23 inspection finale avant de quitter l usine La garantie est valable pendant un an par tir de la date de livraison et couvre tous les d fauts dus une d faillance de mat riaux ou de fabrication La garantie ne couvre pas l usure normale ainsi que tout dommage provoqu par une utilisation non appropri e par exemple incompatibilit chimique des mat riaux etc Cette garantie s tend uniquement au rem placement ou la r paration des produits d ficients notre libert d appr ciation Cette garantie est nulle si le client ou des tiers modifient d une quelconque mani re les produits fournis par nous Les d fauts doivent tre imm diatement d clar s au fournisseur d s leur constata tion et dans tous les cas au cours de la p riode de garantie 9 Dimensions du support 850 Rs FI
19. r Toledo GmbH InDip 550 Printed in Switzerland 52 400 739 20 4 2 InDip 550 V rifier la connexion du c ble de masse vert jaune au contact du converde Remettre en place l crou chapeau et le presse amp foupe Ne pas encore resserrer celui ci Raccorder le c ble de connexion l lectrode ou la sonde V rifier la connexion de la masse liquide au c ble vert jaune Emboiter nouveau l adaptateur dans le tube Tirer l g rement sur le c ble et serrer ensuite le presse toupe sur celui ci Suivre la proc dure nonc e ci dessus dans le sens inverse pour retirer l lectrode ou la sonde du support en commen ant par d serrer le presse toupe Important Pour les c bles de dia m tres inf rieur 5 mm utiliser le set de joint de rechange appropri livr dans le sachet plastique avec le support Pour les sondes de turbidit il est n cessaire de commander le set appropri P N 52400785 Important Nettoyer correctement le support avant de deboiter l adaptateur et veiller garder les surfaces et les joints toriques propres pour assurer l tanch it Important faut absolument d serrer le presse toupe autour du c ble avant de d sembo ter l adaptateur Installation du support Les supporis InDip 550 peuvent tre fix s directement sur la paroi du canal ou du r servoir de b ton Pour les d tails de fixation observer les instructions de montage jointe au set de fixation II
20. r holder Unscrew the cover with cap nut and gland Thread the cable through the gland The ca ble from the cover towards the tube must be about 10 cm longer than the length of the tube Check the connection of the grounding cable yellow green to the pin of the cover Thread the cable through the tube and reattach the cover with cap nut Screw the sensor hand tight into the holder Connect the cable to the sensor Check the connec tion of the grounding cable to the solution grounding pin Snap the sensor holder into the tube Straighten the cable with a light tug and tighten the gland Important If the cable diameter is less than 5 mm the set of seals supplied in a pouch together with the housing must be used In the case of turbidity sensors please use the special set of seals P N 52400785 Important Loosen the cable gland before pulling the sensor holder out of the tube 06 04 Mettler Toledo GmbH InDip 550 Printed in Switzerland 52 400 739 6 InDip 550 Important Clean the housing before pulling the sensor holder out of the tube Clean the surface and seals before mounting For removal of the sensor carry out the above procedure in the reverse order 4 2 Installation of the housing The housing InDip 550 can be attached to the wall of a channel or basin by means of a special mounting set For details refer to the instructions supplied with the mounting set It is advisable to install the housing in such
21. rbidit en particulier dans les applications des eaux industrielles La connexion m le femelle pour le raccordement du c ble sur la t te de l lectrode simplifie le remplacement de celle ci Toutes les parties du support en contact avec le milieu sont soit en PVC ou PVDF selon le mat riel command Tous les joints toriques sont en Viton Le contact de masse liquide est en acier inox 1 4435 type PVC ou Hastelloy C 22 type PVDF Proc dures d installation et de mise en marche Le support est livr enti rement mont Proc der de la mani re suivante pour installer l lectrode ou la sonde dans le support Montage de l electrode ou de la sonde dans le support Pour les sondes de diam tre 12 mm avec Pg13 5 s assurer que la rondelle teflon blanche se trouve directement en dessous de la t te de l lectrode ou de la sonde la partie conique biseaut e tourn e vers le bas Le joint torique est plac apr s la rondelle D bo ter l adaptateur en le sortant du tube sans le tourner Au besoin s aider d un tournevis en l introduisant dans la fente entre le tube et l adaptateur Visser ensuite l electrode ou la sonde en la serrant la main dans l adaptateur D visser l crou chapeau d serrer l amp crou du presse toupe et passer le c ble de connection travers celui ci Le c ble c t mesure devrait tre environ 10 cm plus long que le tube Passer le c ble dans le tube 06 04 Mettle
22. s Sensors in die Armatur F r 12 mm Sensoren mit Pg 13 5 Achten Sie darauf dass die weisse Teflon Gleit scheibe direkt unterhalb des 12 mm Elektro den Sensorkopfes positioniert wird mit der Abschr gung nach unten gerichtet Erst dann folgt der O Ring Elektrodenhalter ohne Drehung aus dem Rohr herausziehen Falls notwendig mit ei nem Schraubenzieher zwischen Rohr und Elektrodenhalter nachhelfen Deckel mit der berwurfmutter und Kabel verschraubung abschrauben Kabel durch die Kabelverschraubung f hren Die Kabel l nge rohrseitig ab Deckel muss ca 10 cm l nger als die Rohrl nge sein Verbindung zwischen Erdungskabel Stecker und Deckel kontrollieren Kabel durch das Rohr f hren und Deckel mit berwurfmutter befestigen Elektrode oder Sensor handfest in den Elek trodenhalter einschrauben Kabel mit der Elektode oder mit dem Sensor verbinden Verbindung zwischen Erdungskabel Stecker InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 13 und Potentialausgleich Stift kontrollieren Den Elektrodenhalter in das Rohr ein schnappen Das Kabel mit leichtem Zug strecken und die Kabelverschraubung an ziehen Wichtig F r Kabel mit einem Durch messer kleiner als 5 mm verwenden Sie unbedingt das im Beutel beigeleg te Dichtungsset F r die Tr bungs sensoren Verwenden Sie bitte das spezielle Set P N Wichtig Armatur sorgf ltig reinigen vor dem Herausziehen des E halters
23. tte brochure d instructions Les supports sont destin s contenir uni quement des sondes METTLER TOLEDO tout autre type d utilisation pourrait tre dangereux et n est pas autoris Les mat riaux utilis s dans le support sont d crits au chapitre 3 Description du produit et des mat riaux S assurer que les mat riaux sont adapt s l appli cation requise S assurer que le support est convenable ment install et entretenu suivre les in structions donn es dans cette brochure Une mauvaise manipulation du support peut provoquer la rupture d une lectrode et des fuites du milieu InDip 550 06 04 Mettler Toledo GmbH 52 400 739 Printed in Switzerland InDip 550 19 4 1 S assurer que l installation est s re avant d intervenir sur le support lib rer la pres sion vider rincer ventiler purger etc Utiliser uniquement des lectrodes ou des sondes des supports et des manchons propres Remplacer imm diatement les pi ces et composants du support qui sont endommag s Toujours v rifier le syst me de mesure avant la mise en marche Examiner l en semble support lectrode et rechercher d ventuelles fuites Consulter votre fournisseur en cas de doute Description du produit et des mat riaux Ces types de supports prot gent les lectro des ou les sondes des dommages m cani ques pour les mesures de pH redox d oxy g ne de conductivit ou de tu