1. LIGHTMASTER LANDSCAPE LIGHTING MOTION SENSOR i INSTRUCTION MANUAL Congratulations on selecting your new Landscape Lighting Motion Sensor The Landscape Lighting Motion Sensor connects directly into the Orbit LightMaster Landscape LED Light Controller to provide additional security comfort and beauty to your home and yard MOTION SENSOR FEATURES e Passive Infrared Motion Sensor e 120 motion detection e Up to 40 ft range e Wall or yard mounting stake included INSTALLATION Tools Required e Wire Cutters Strippers e Phillips Screwdriver e Two screws if wall mount is desired Drill Bit if wall mount is desired e Power Drill if wall mount is desired Yard Installation 1 Select a location in your yard such as a flowerbed or garden near an area you want motion to be detected 2 Insert stake until platform is flush and level with the ground 3 Adjust the sensor head to optimize motion detection pointing it towards the area most likely to receive motion Note The Motion Sensor should not be placed in a location that is beyond the length of its chord approximately 8 ft Wall Installation 1 Select a location on a wall near an area you want motion to be detected 2 Remove sensor head from plastic stake by sliding the head up 3 Install a screw into the lower pre formed hole before doing the same with the upper pre formed hole 4 Adjust the sensor head to
2. n El sensor de movimiento para iluminaci n de jard n se conecta directamente en el controlador de iluminaci n LED de jard n Orbit LightMasterTM para brindarle m s seguridad comodidad y belleza a su hogar y al patio CARACTER STICAS DEL SENSOR DE MOVIMIENTO e Sensor de movimiento infrarrojo pasivo e Detecci n del movimiento de 120 e Hasta 12 2 m de alcance e Montaje en la pared o en el patio se incluye estaca INSTALACI N Implementos necesarios e Alicates cortacables pelacables e Destornillador de estrella e Dos tornillos si desea montarlo en la pared e Broca de taladro si desea montarlo en la pared e Taladro el ctrico si desea montarlo en la pared Instalaci n en el patio 1 Elija un lugar del patio tal como un cantero o un jard n cerca de un rea donde desea que se detecte el movimiento 2 Inserte la estaca hasta que la plataforma est a ras y a nivel con la tierra 3 Ajuste el cabezal del sensor para optimizar la detecci n del movimiento apunt ndolo hacia el rea m s propensa a que ocurra el movimiento Nota El sensor de movimiento no debe colocarse en un lugar que est m s all del largo de su cable aproximadamente 2 44 m Instalaci n en la pared 1 Elija un lugar en una pared cerca de un rea en la cual desea que se detecte el movimiento y HAHAI 2 Retire el cabezal del sensor de la estaca pl stica deslizando el cabezal hacia arriba
3. p ex une maison une terrasse e en Uenfouissant moins de 15 24 cm 6 po de profondeur pour le raccorder au c ble basse tension principal e en coupant le c ble de mani re ce qu il soit raccord un connecteur moins de 15 24 cm 6 po d un b timent d un luminaire o d un raccord e Ce produit ne doit tre utilis qu avec des blocs d alimentation pour clairage paysager tension de sortie faible d un maximum de 12 V et de classe 2 SOUTIEN TECHNIQUE www orbitonline com Avant de retourner ce dispositif de commande votre distributeur Orbit autoris communiquez avec le service technique d Orbit au num ro suivant 1 800 488 6156 Communiquez avec votre fournisseur local d alimentation lectrique pour acheter des rallonges basse tension suppl mentaires pour Le raccord des appareils NONC DE GARANTIE Orbit garantit ses clients que ses produits seront exempts de tout d faut de mat riaux ou de fabrication pendant une p riode de cinq ans compter de la date d achat Printers are responsible for meeting print production requirements Any changes COLORS EE E Registration non printing Black DES KM color CLIENT Orbit non printing PMS SKU 86730 urc N A must be approved by the client and Fluid Studio PRINTED PIECE MUST MEET DESIGNATED SPECIFICATIONS ON THIS FORM 2013 Fluid Studio This work is the pro
4. Utah 84010 e Landscape lights by Orbit LightMasterTM do not use tungsten halogen bulbs unless marked for such e Protect your low voltage cable by e Routing it in close proximity to the light or fitting e Routing it next to a building structure e g house deck e Do not bury deeper than 6 inches 15 2 cm in order to connect to the main low voltage cable e Trim the cable length so that it is attached to a connector within 6 inches 15 2 cm from a building structure a landscape light or a fitting e This product is only for use with low voltage landscape lighting power units with a maximum output rating of 12 volts Class 2 Only HELP www orbitonline com Before returning this controller to your authorized Orbit distributor contact Orbit Technical Service at 1 800 488 6156 Please contact your local electrical supply retailer to purchase additional lengths of main low voltage cable for connection of equipment WARRANTY AND STATEMENT Orbit warrants to its customers that its products will be free from defects in materials and workmanship for a period of five years from the date of purchase We will replace free of charge the defective part or parts found to be defective under normal use and service for a period of up to five years after purchase proof of purchase required Orbit reserves the right to inspect the defective part prior to replacement Orbit will not be responsible for consequential or incidental
5. 3 Coloque un tornillo en el agujero preformado E inferior antes de hacer lo mismo con el agujero preformado superior 4 Ajuste el cabezal del sensor para optimizar la detecci n del movimiento Nota El sensor de movimiento no debe colocarse q ES en un lugar que est m s all del largo de su cable p laproximadamente 2 44 m Conexi n del sensor de movimiento al terminal 1 Separe los tres cables solo lo suficiente para permitir la instalaci n conectados al sensor de movimiento STATION Light MOTION SENSOR com 1 2 3 SENSOR balcon 1 2 3 POP 2 Pele 13 mm del aislamiento pl stico del extremo de cada cable Afloje lo necesario de los tornillos terminales Cable negro 3 4 Inserte el cable rojo en el terminal de alimentaci n 5 Inserte el cable negro en el terminal com n 6 Inserte el cable blanco en el terminal de la estaci n adecuada Nota Si instala m s de un sensor de movimiento debe insertar varios cables de alimentaci n rojos en el terminal nico de alimentaci n Debe insertar varios cables comunes negros en el terminal com n nico Los cables blancos se insertar n en el terminal de la estaci n adecuada Para que el sensor de movimiento funcione debe ingresar las horas de inicio las horas de parada y las horas del sensor en su controlador de iluminaci n 7 Fije los cables apretando los tornillos ADVERT
6. ENCIAS e El cable principal de bajo voltaje debe enterrarse superficialmente a menos de 15 24 cm e ADVERTENCIA Riesgo de descarga el ctrica Instale todas las l mparas a 3 05 m o m s de una piscina ba era de hidromasaje o fuente e Las luces de paisajismo de Orbit LightMaster no utilizan bombillas hal genas con filamentos de tungsteno a menos que est indicado e Proteja su cable de bajo voltaje como sigue e Canal celo en la proximidad de la luz o el adaptador e Canal celo cerca de una edificaci n p ej una casa una terraza e No lo entierre a mayor profundidad de 15 24 cm para conectarlo al cable principal de bajo voltaje e Recorte el largo del cable para que quede fijado a un conector dentro del espacio de 15 24 cm de una edificaci n una luz de paisajismo o un conector e Este producto se debe usar nicamente con unidades de alimentaci n de luz para jard n de bajo voltaje con una salida m xima de 12 voltios solo de clase 2 AYUDA www orbitonline com Antes de devolver este controlador al distribuidor autorizado Orbit comun quese con el Servicio T cnico de Orbit al 1 800 488 6156 Comun quese con su distribuidor local de suministros el ctricos para comprar m s cable principal de bajo voltaje para conectar equipos GARANT A Y DECLARACI N Orbit garantiza a sus clientes que sus productos no tendr n defectos en los materiales ni en la mano de obra durante un per odo de cinco a
7. able de la conformit peuvent annuler le droit de l utilisateur de se servir de cet appareil Remarque Cet appareil a t test et d clar conforme aux limites impos es aux dispositifs num riques de classe B conform ment l alin a 15 du r glement de la FCC Ces limites sont destin es assurer une protection raisonnable contre les interf rences nuisibles dans un environnement r sidentiel Cet appareil g n re utilise et peut mettre de l nergie radiofr quence et s il n est pas install et utilis conform ment aux instructions risque de provoquer des interf rences nuisibles aux communications radio Cependant tout risque d interf rence ne peut tre totalement exclu S il constate des interf rences lors de la r ception d missions de radio ou de t l vision il suffit pour le v rifier d allumer et d teindre successivement l appareil l utilisateur devra prendre les mesures n cessaires pour les liminer cette fin il devra e r orienter ou d placer l antenne r ceptrice e accro tre la distance entre l appareil et le r cepteur e brancher l appareil sur une prise de courant appartenant un autre circuit que celui du r cepteur e obtenir de l aide aupr s du d taillant ou d un technicien en radio ou en t l vision exp riment LIGHTMASTER MANUAL DE INSTRUCCIONES DEL SENSOR DE MOVIMIENTO Felicitaciones por seleccionar su nuevo sensor de movimiento para iluminaci n de jard
8. cost or damage caused by the product failure Orbit liability under this warranty is limited solely to the replacement or repair of defective parts To exercise your warranty return the unit to your authorized distributor with a copy of the sales receipt This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or
9. further optimize motion detection Note The Motion Sensor should not be placed in a location that is beyond the length of its chord approximately 8 ft Connecting your Motion Sensor to Terminal 1 Separate the three wires only enough for SANO o ACTION SENSO installation F RAAE connected to your motion sensor TT 2 Strip inch 12 mm of the plastic insulation Reg wire ss Me off the end of each wire Loosen the necessary terminal screws Black wire OTE Insert red wire into the power terminal Insert black wire into the common terminal 0 0 Pp Insert white wire into the appropriate station terminal Note If installing more than one motion sensor multiple power red wires will be inserted into the single power terminal Multiple common black wires will be inserted into the single common terminal White wires will be inserted into the appropriate station terminal For motion sensor to operate start times stop times and sensor times must be entered into your Lighting Controller 7 Secure the wires by tightening the screws WARNINGS e The main low voltage cable is intended for shallow burial less than 6 inches 152 mm e WARNING Risk of Electric Shock Install all luminaries 10 feet 3 05 m or more from a pool spa or fountain P 801 295 9820 F 801 951 5815 www fluid studio net 1065 South 500 West Bountiful
10. installation mais sans plus Fil rouge 2 D nudez l extr mit de chaque fil sur environ 12 mm 1 2 po Fil noir E Desserrez les vis de borne n cessaires ns rez le fil noir dans la borne commune 3 4 Ins rez le fil rouge dans la borne d alimentation 5 6 ns rez le fil blanc dans la borne de la zone appropri e Remarque Si vous installez plus d un d tecteur de mouvement ins rez tous les fils d alimentation rouges dans la m me borne d alimentation Ins rez tous les fils communs noirs dans la m me borne commune Ins rez les fils blancs dans la borne de la zone appropri e Pour que le d tecteur de mouvement fonctionne il vous faut entrer les heures de fonctionnement ainsi que les heures de vmise en marche et les heures d arr t dans votre dispositif de commande 7 Fixez les fils en serrant les vis AVERTISSEMENTS e Le c ble basse tension principal est concu pour un enfouissement superficiel moins de 15 24 cm 6 po de profondeur e AVERTISSEMENT Risque de choc lectrique Installez toujours Le luminaire au moins 3 05 m 10 pi d une piscine d un spa ou d une fontaine e N utilisez pas d ampoules au tungst ne halog ne pour les luminaires pour am nagement paysager de Orbit LightMasterTM sauf si indiqu e Prot gez votre c ble basse tension comme suit e en l acheminant tr s pr s du luminaire ou du raccord e en Uacheminant Le long d un b timent
11. l mites se han dise ado para proporcionar una protecci n razonable contra la interferencia perjudicial en una instalaci n residencial Este equipo genera utiliza y puede irradiar energ a de radiofrecuencia y si no se instala y usa de acuerdo con las instrucciones puede causar interferencia perjudicial a las comunicaciones de radio Sin embargo no se garantiza que no se producir n interferencias en una instalaci n en especial Si este equipo genera una interferencia perjudicial para la recepci n de radio o televisi n que se puede determinar apagando y encendiendo el equipo se recomienda al usuario que intente corregir la interferencia con una o m s de las siguientes medidas e Reorientar o reubicar la antena de recepci n e Aumentar la separaci n entre el equipo y el receptor e Conectar el equipo a un tomacorriente de un circuito distinto al que usa el receptor e Solicitar ayuda al concesionario o a un t cnico con experiencia en radio TV Orbit Inc North Salt Lake UT 84054 1 800 488 6156 www orbitonline com PN 86730 24 rA
12. more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult with the dealer or an experienced radio TV technician for help COrbit gt LIGHTMASTER MANUEL D INSTRUCTIONS DU DETECTEUR DE MOUVEMENT F licitations pour l achat de votre nouveau d tecteur de mouvement pour clairage pour am nagement paysager Le d tecteur de mouvement pour clairage pour am nagement paysager se raccorde directement au dispositif de commande pour clairage pour am nagement paysager DEL d Orbit LightMasterT afin d assurer une s curit un confort et une l gance accrus pour votre maison et votre cour CARACT RISTIQUES DU D TECTEUR DE MOUVEMENT e d tecteur de mouvement infrarouge passif ul e d tection des mouvements sur 120 e port e de d tection allant jusqu 12 19 m e installation murale ou au sol piquet inclus PROOE NO 4 DIMENSIONS FLAT W 13 5 H 14 0 DATE 08 28 13 FINISHED W 4 5 D H 7 0 INSTALLATION Outils n cessaires e coupe fil ou pinces d nuder e tournevis cruciforme e deux vis pour installation murale e foret pour installation murale e perceuse lectrique pour installation murale Installation dans la cour 1 Choisissez un em
13. os a partir de la fecha de compra Reemplazaremos sin costo alguno el componente o los componentes defectuosos que hayan estado en condiciones de uso y servicio normales durante un per odo de hasta cinco a os despu s de la compra se requiere comprobante de compra Orbit se reserva el derecho de revisar el componente defectuoso antes de reemplazarlo Orbit no se responsabilizar por los da os ni costos incidentales ni resultantes ocasionados por la falla del producto La responsabilidad de Orbit en virtud de esta garant a se limita nicamente al reemplazo o la reparaci n de los componentes defectuosos Para hacer valer su garant a devuelva la unidad a su distribuidor con una copia del recibo de venta Este dispositivo cumple con la Secci n 15 del Reglamento FCC El funcionamiento est sujeto a las dos condiciones siguientes 1 este dispositivo no debe causar interferencia perjudicial y 2 este dispositivo debe aceptar cualquier interferencia recibida incluso la interferencia que pudiese producir un funcionamiento no deseado ADVERTENCIA Las modificaciones o los cambios realizados en esta unidad que no est n expresamente aprobados por la parte responsable del cumplimiento pueden anular la autoridad del usuario para hacer funcionar el equipo Nota Este equipo ha sido probado y se ha verificado que cumple los l mites para un dispositivo digital clase B conforme a la secci n 15 de las reglas de la FCC Estos
14. perty of Fluid ADDITIONAL INSTRUCTIONS Accordian Style Trifold FILE NAME 86730 24 RA indd Proofing Code LB1006978 SOFTWARE InDesign CS6 Studio and cannot be used reproduced or distributed in any way without their express permission Pendant une p riode de cinq ans apr s la date d achat nous remplacerons sans frais les pi ces d fectueuses ou qui s av reront d fectueuses si elles ont t soumises des conditions normales d utilisation et d entretien une preuve d achat est n cessaire Orbit se r serve le droit d inspecter toute pi ce d fectueuse avant de la remplacer Orbit n est pas responsable des dommages ou co ts accessoires o cons cutifs caus s par une d fectuosit du produit En vertu de la pr sente garantie la responsabilit d Orbit se limite exclusivement au remplacement ou la r paration des pi ces d fectueuses Pour vous pr valoir de votre garantie renvoyez l article votre distributeur autoris accompagn d une copie de votre recu Cet appareil est conforme l alin a 15 du r glement de la FCC Son utilisation est soumise aux deux conditions suivantes 1 cet appareil ne doit provoquer aucune interf rence nuisible et 2 cet appareil doit accepter toute interf rence re ue y compris les interf rences pouvant entra ner un fonctionnement ind sirable AVERTISSEMENT Les modifications non autoris es express ment par la partie respons
15. placement dans votre cour comme des plates bandes ou un jardin situ pr s d une zone o vous d sirez d tecter du mouvement 2 Enfoncez le piquet dans le sol jusqu ce qu il soit parfaitement ins r et au niveau du sol 3 Positionnez la t te du d tecteur pour optimiser la d tection du mouvement en la pointant en direction de la zone la plus susceptible de recevoir du mouvement Remarque Le d tecteur de mouvement doit tre plac une distance inf rieure 2 44 m soit la longueur de son cordon d alimentation STEN E sE E gt PA Installation murale 1 Choisissez un emplacement sur un mur situ pr s d une zone o vous d sirez d tecter du mouvement 2 D tachez la t te du d tecteur du piquet en plastique en la glissant vers le haut 3 Ins rez une vis dans le trou pr perc inf rieur puis faites la m me chose pour le trou pr perc sup rieur 4 Positionnez la t te du d tecteur pour optimiser la d tection de mouvement Us Remarque Le d tecteur de mouvement doit tre plac une distance inf rieure 2 44 m soit la longueur de son cordon d alimentation Raccorder le d tecteur de mouvement la STATION cur MOTION SENSOR borne con oi pe e soja e s 1 D tachez les trois fils raccord s votre POSPSOCHOVOVLOE d tecteur de mouvement de facon bla permettre l