Home
CD-2PLUS
Contents
1. Porter s Exchange x Terms Backbone Logical address D FA PLUS C Master Slave Lock release 2 E 2 28 DESCRIPTION C onverter description DIN guide releasing flange Self testing leds Configuration dip switch Connection block INSTALLATIO N E onverter installation Install the converter in a dryand protected place free from the risk of drip or water projections To avoid damage the converter must be firmly fixed Install or modify the equipment without the power 93 5 x 45 connected DIN 7971 The installation and handling of this equipment must be performed by authorised personnel To install the converter directly on the wall drill two holes of 9 6mm and insert the wallplugs Fix the converter with the specified screws 03 5 x 45 di DIN 7971 y The converter can be installed on a DIN guide 6 elements pressing itlightly To extract the converter from the DIN guide use a plain screwdriver to lever the flange as shown in the picture ma SS CONFIGURATION 29 escription of the configuration dip switch of CD 2PLUS module The SW1 configuration dip switch is found at the upper right side of the module Setto O N the switch number 1 to programme the backbone This function must be done only in case the module is being used as backbone encoder see page 27 O nce the programming process is
2. If so make sure the programming of the backbone in the converters has been done appropriately page 30 and check the wiring page 33 and the configuration page 29 lt If not revise the telephones programming see the door panel manual and if necessary repeatthe programming steps lt Check also the voltage between the and terminals of the several elements is about 17 5 to18 5Vc c otherwise check the power supply and wiring c The converter can notbe programmed lt Check the coded panel is setto the configuration mode before setting the switch number 1 to ON see page 29 and thatthe programming sequence is correct amp Check the BUS terminals are notshort circuited between them nor any other terminal Backbone encoder mode Coded panel s Callscan notbe done amp Remember that once the power supply is plug in the system remains inactive for 45 sec likewise when connecting any other unitinto the installation amp Make sure the converter has notany backbone programmed to do it setthe switch number 2 to OFF and then putitback to its correct position O N like this the backbone programming is reset lt Review the converter wiring page 32 and its configuration page 29 amp Check also the voltage between and terminals of the several elements is about17 5 to 18 5Vd c otherwise check the power supply and wiring 36 NO TAS NOTES NOTAS NO TES 31
3. 38 NO TAS NOTES GONFORMIDAD COMPLIANCE CONFORMITE 39 Este producto es conforme con las disposiciones de las Directivas Europeas aplicables respecto Compatibilidad Electromagn tica 2004 108 CEE asi como con la ampliaci n en la Directiva del Marcado CE 93 68 CEE This product meets the essentials requirements of applicable European Directives regarding Electromagnetic Compatibility 2004 108 ECC and as amended for CE Marking 93 68 ECC amp NOTA El funcionamiento de este equipo esta sujeto a las siguientes condiciones 1 Este dispositivo no puede provocar interferencias da inas y 2 debe aceptar cualquier interferencia recibida incluyendo las que pueden provocar un funcionamiento no deseado NOTE O peration is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept any received interference including the ones that may cause undesired operation a golmar golmar es iG www golmar es 2000 SGS G olmar se reserva el derecho a cualquier modificaci n sin previo aviso G olmar se r serve le droit de toute modification sans pr avis G olmar reserves the right to make any modifications without prior notice
4. FA PLUS C rev 938072 PRI 230 110 O Reseau FA PLUS C rev 938072 O Principale Secondaire gt Plaque G n rale Plus R de communications DESACTIVEE PRI 230 110 O Reseau cy cv RTA VV VTV P outl in in fine Motel out A la Aux plaque es suivante es RESO LUTIO N DES PRO BLEMES 23 Mode interface de centrale de condergerie La centrale ne recoitpas des appels dela plaque lt V rifier si la centrale peut recevoir des appels d s n importe quel autre poste en poussant le bouton de g che avec le combin d croch lt Encasaffirmatif v rifier dans la configuration de la centrale que l option capturer plaque est activ e etque la plaque a le micro interrupteur numero 3 en position O N lt En casn gatif v rifier que la centrale n estpas teinte l cran montre une ligne de points Le led rouge doit tre toujours allum amp V rifier aussi la connexion page 19 etla configuration page 17 du convertisseur Mode codificateur de la colonne montante Plaques g n rales o n estpas possible de r aliser des appels d s les plaques g n rales V rifier si des appels sont possibles d s les plaques int rieures amp En cas affirmatif v rifier la correcte programmation de l
5. C d 50124604 Convertidor de protocolo CD 2PLUS version francais page 12 english version page 24 D gt INTRO DUCCION Ante todo le agradecemos yfelicitamos porla adquisici n de este producto fabricado por G olmar Nuestro compromiso por conseguir la satisfacci n de clientes como usted queda manifiesto por nuestra certificaci n ISO 9001 ypor la fabricaci n de productos como el que acaba de adquirir La avanzada tecnolog a de su interior y un estricto control de calidad har n que clientes y usuarios disfruten de las innumerables prestaciones que este equipo ofrece Para sacar el mayor provecho de las mismas y conseguir un correcto funcionamiento desde el primer d a rogamos lea detenida mente este manual de instrucciones NDICE Introducci n ndice setena bia fet tah ek eh SG Laat Nk ih SO lane Nt ih SO ane To Ao eh ee da Consejos para la puesta en marcha Precauciones de seguridad Caracter sticas del siii ii Ara dada a Modos de funcionamiento Descripci n Instalaci n vainas Configuraci n del microinterruptor Leds autodia GN SUiCO iii daa Programaci n del canal Esquemas de instalaci n Modo interface de central Modo codificador de canal placa codificada Modo codificador de canal placas generales Soluci n de aver Sis a a ds CONSEJOS PARA LA PUESTA EN MARCHA o La instalaci n y manipulaci n de este equipo debe ser realizad
6. A Red BUS HZHZ BUS HZHZ FA PLUS C ver 938072 CD 2PLUS a PRI SEC BUS D A 230 110 O ie P Principal O Secundario Placa 2PLUS FA PLUS C ver 938072 PRI SEC 230 110 0 Red IMPORTANTE Para la configuraci n y programaci n de cada equipo ver el manual de producto correspondiente ESQ UEMAS DE INSTALACI N M odo codificador de canal placa codificada A la siguiente planta gt Placa codificada Plus T 7720 HZ HZ STADIO Placa 2PLUS SS FA PLUS C ver 938072 PRI 0000 INOX 230 110 0 COCO DODO 008 Red FA PLUS C ver 938072 PRI SEC 230 110 0 4 Red O Principal Secundario FA PLUS C ver 938072 aga Placa codificada Plus E R de comunicaciones ACTIVADA PRI 7 110 E cut IMPORTANTE Para la configuraci n y programaci n de cada equipo ver el manual de producto correspondiente ESQUEMAS DE INSTALACI N 9 M odo codificador de canal pl
7. du guide utiliser un tornevis plat et effectuer un mouvement de levier comme indiqu sur le sch ma ci joint CO NFIGURATIO N 17 D escription du micro interrupteur de configuration du module CD 2PLUS olz Le micro interrupteur de configuration SW1 est plac dans la EFE partie sup rieure droite du module Placeren position ON pourla programmation de la colonne montante Cette fonction ne doit pas tre r alis e en cas d utiliser le module comme configurateur de colonne montante voir page 15 Une fois finalis la programmation le placer en position O FF nouveau Placer en position ON pour activer le mode codificateur de colonne montante Placer en position O FF pour activer le mode interface de centrale Voir pages 14 et 15 R glage de fabrique maintenir toujour en position O FF N est pas utilis Valeur de fabrique D escription des leds d auto diagnostic SS Les leds d auto diagnostic sont plac s a c t des micro interrupteurs Hi de configuration Led vert Fixe Fonctionnement correct Clignotementlent Convertisseur en programmation Clignotementrapide Programmation fini En cas d interf rence si celle ci et Led rouge r solue avant pass s 2 minutes Fixe Il ya une plaque configur comme principale environ la plaque r tablira son fonctionnement automatiquement En cas contraire il faudra deconnecter et connecter nouveau C
8. finished return the switch to O FF Set to ON the switch number 2 to activate the mode backbone encoder Set to OFF to activate the mode porter s exchange interface see pages 26 27 Factory adjustment Keep it always O FF Not used Factory default A D escription of the self testing leds The self testing leds are placed together with wit Fi the configuration dip switch Green Led Fixed C orrect operation Slow blinking Programming of converter in progress Quick blinking Programming has finished In case of crossed line if it is removed before 2 minutes approx the door Red Led panel will automatically reset in case Fixed There is a door panel configurated as master of more than 2 minutes it is necessary to switch itoffand then switch iton Blinking There is a crossed line in the installation between bus wires 30 BACKBO NE PRO GRAMMING Prose mming the converter In case of using this module as a backbone encoder general door panel see page 27 a different backbone code mustbe programmed in every converter following these steps GOLMAR Access into the panel programming mode by 13 15 pressing the key button followed by the secret code of installer factory default 1315 as itis shown on the door panel manual Activate the converter programming set to ON the switch number 1 The door panel emits a tone and the green led of the converter starts
9. llamadas desde cualquier tel fono pulsando el bot n abrepuertas con el auricular descolgado amp En caso afirmativo compruebe en la configuraci n de la central que la opci n capturar placa se encuentra activada y que en la placa tiene el microinterruptor n mero 3 enON lt En caso negativo compruebe que la central no se encuentra apagada la pantalla muestra una l nea de puntos tenga en cuenta que el led rojo siempre est encendido amp Compruebe tambi n el conexionado p g 7 yconfiguraci n p g 5 del convertidor Modo codificador de canal Placas generales No se pueden realizar llamadas desde las placas generales lt Compruebe si puede realizar llamadas desde las placas interiores lt En caso afirmativo asegurese de haber programado correctamente el canal en los convertidores p g 6 y revise el conexionado de los mismos p g 9 y su configuraci n p g 5 amp En caso negativo revise la programaci n de los tel fonos ver manual de la placa volviendola a realizar si fuera necesario amp Compruebe tambi n que la tensi n entre los bornes y de los diferentes elementos es de 17 5 a 18 5Vc c sino esas compruebe el alimentador ysu conexionado No se puede programar el convertidor amp Compruebe que la placa general se encuentra en modo de configuraci n antes de colocar el microinterruptor n mero 1 en ON ver p gina 5 y que la secuencia de programaci n esla correcta amp Comp
10. panel To the next floor T 7720 Coded panel Plus HHZHZ STADIO 2PLUS Door Panel SS FA PLUS C ver 938072 PRI 0000 INOX 230 110 0 O00 99090 900 Main FA PLUS C ver 938072 PRI SEC 230 110 0 Main Master Slave FA PLUS C ver 938072 Coded Panel Plus O Communication R ACTIVATED PRI T 110 A Ga IMPORTANT For the configuration and programming of each equipment see the corresponding manual INSTALLATION DIAG RAMS 33 Br encoder mode general entrance door panels Coded panel Plus To the next floor Building 1 2PLUS Door Panel STADIO IE FA PLUS C rev 938072 909 060 119000 000 eos INOX FA PLUS C rev 938072 ROCK FA PLUS C rev 938072 Z gt General door panel Plus M Communications Resistor ENABLED IMPORTANT For the configuration
11. panel with the same power supply The converter could be damaged c To avoid damage the converter has to be firmly fixed SYSTEM CHARACTERISTICS O o Protocol converter for 2PLUS system that allows DAssembling a porter s exchange Plus in a 2PLUS installation DAssembling general door panels Plus with inner access into 2PLUS system DAssembling a coded door panel Plus with 2PLUS telephones ce Up to 250 converters per installation o Up to120 apartments and 120 telephones per backbone o Easy configuration by means of an easy accessible switch o Self testing leds that can detect installation and or programming failures o Necessary a dedicated FA Plus C power supply to protocol converter module O PERATION MO DES The CD 2PLUS converter has 3 possible operation modes Porter s Exchange interface A CE 941 Plus porter s exchange can be inserted between the door panel and the telephones so that the common functions of this unit can be done panel call 2PLUSTelephones pickup receive and do calls to apartments transfer calls from door panel to apartments storage unanswered calls of apartments etc Maximum one panel per system O nly a panel send the call to porter s exchange Installation diagram on page 31 CE 941 Plus CD 2PLUS Slave ye 2 O Master Lock release FA PLUS C p es es es es Continue O PERATIO N MO DES 21 Com
12. N escripci n del microinterruptor de configuraci n del m dulo CD 2PLUS ui z El microinterruptor de configuraci n SW1 est ubicado Frit en la parte superior derecha del m dulo Colocaren ON para programar el canal Esta funci n solo debe realizarse en caso de utilizar el m dulo como configurador de canal ver p gina 3 Finalizada la programaci n volverlo a colocar en O FF Colocaren ON para activar el modo codificador de canal Colocar en O FF para activar el modo interface de central Ver p ginas 2 y 3 Ajuste de f brica mantener siempre en O FF No se utiliza Valor de f brica A D escripci n de los leds de autodiagn stico Los leds de autodiagn stico est n ubicados junto al microinterruptor de configuraci n Led verde Fijo Funcionamiento correcto Parpadeo lento Convertidor en programaci n Parpadeo r pido Programaci n finalizada x En caso de cruce si este se elimina Led rojo antes de 2 minutos aprox la placase Fijo Hay una placa configurada como principal rearmar autom ticamente pasado este tiempo ser necesario desconectar y volver a conectar la alimentaci n Parpadeando Existe un cruce en la instalaci n entre los hilos del bus PRO G RAM AC I N DEL CANAL Pass del convertidor En caso de utilizar este m dulo como codificador de canal placas generales ver pag 3 se deber programar un c digo de canal diferente e
13. S FA PLUS C ver 938072 PRI SEC 23010 0 ne Reseau O Principale Secondaire FA PLUS C ver 938072 ages k Plaque Codifi e Plus E R de communications ACTIV E PRI 7 110 E out Reseau IMPORTANT Pour la configuration et programmation de chaque quipe voir le manuel de produit correspondant SCHEMAS INSTALLATIO N 21 M ode codificateur de colonnes montantes plaques de rue g n rales Plaque Codifi e Plus Dans l tage suivant B timent 1 Plaque 2PLUS STADIO Je FA PLUS C rev 938072 seo 808 000 000 eos o PRI 230 110 O aaoo INOX OOOO Reseau 00 FA PLUS C rev 938072 PRI SEC 2301110 0 Reseau FA PLUS C rev 938072 Z gt Plaque G n rale Plus P R de communications ACTIVEE 230 110 O Reseau in ins outs out IMPORTANT Pour la configuration et programmation de chaque quipe voir le manuel de produit correspondant 22 FA PLUS C rev 938072 Dans l tage suivant B timent 250 Plaque 2PLUS PRI 230 110 0 Reseau
14. a colonne montante des convertisseurs page 18 etr viser sa connexion page 21 etsa configuration page 17 En cas n gatif r viser la programmation des postes voir manuel de la plaque R aliser nouveau la programmation si n cessaire amp V rifier aussi que la tension entre les bornes et des diff rents l ments est de 17 5 18 5Vc c sicen estpasle cas v rifier l alimentation etla connexion c Impossible de programmer le convertisseur amp V rifier que la plaque codifi e est en mode de configuration avant placer le micro interrupteur num ro 1 en position ON voir page 17 et que la s quence de programmation est correcte amp V rifier que les bornes BUS ne souffrent pas un court circuit entre eux ni avec d autres bornes Mode codificateur de colonne montante Plaque codifi e o Impossible de r aliser des appels amp II est important rappeler qu apr s connecter l alimentation l quipement reste inactif pendant 45 seg C estle m me cas si une unit d installation est connect e V rifier que le convertisseur n a aucune colonne montante programm Pour cela placer le mirco interrupteur num ro 2 en position O FF et a nouveau en ON pour r armer la programmation dela colonne montante R viserla connexion du convertisseur page 20 etsa configuration page 17 amp V rifier que la tension entre les bornes et des diff rents l ments est de 17 5 18 5Vc c
15. a por personal autorizado Cuando se instale o modifique el equipo hacerlo sin alimentaci n No apretar excesivamente los tornillos de la regleta del convertidor o Toda la instalaci n debe viajar al menosa 40 cm de cualquier otra instalaci n o Antes de conectar el equipo verificar el conexionado entre placa convertidor tel fonos y el conexionado del alimentador ce Al poner en marcha el equipo por primera vez o tras una modificaci n el sistema permanecer inactivo unos segundos debido al tiempo de arranque c Necesario un alimentador FA Plus C dedicado exclusivamente para alimentar el convertidor c No conecte el convertidor yla placa con un mismo alimentador El convertidor podr a da arse Siga en todo momento las instrucciones de este manual PREC AUCIO NES DE SEGURIDAD Cuando se instale o modifique el equipo hacerlo sin alimentaci n La instalaci n y manipulaci n de este equipo debe ser realizada por personal autorizado se No apretar excesivamente los tornillos de la regleta Toda la instalaci n debe viajar alejada al menosa 40 cm de cualquier otra instalaci n Instale el convertidor en un lugar seco y protegido sin riesgo de goteo o proyecciones de agua Evite emplazamientos cercanosa fuentes de calor h medos o polvorientos No bloquee lasranuras de ventilaci n del convertidor para que pueda circular el aire libremente No conecte el convertidor yla placa con un mis
16. a slow blinking It means the programming has begun Introduce the backbone code to be programmed followed by three zeros then press the bell button The door panel will emit some tones and the green led of the converter starts a quick blinking to show it has been correctly programmed To exitthe programming mode setto O FF the switch number 1 and press the Cancel button of the doorpanel In case of more converters proceed equally introducing a different backbone code in each converter If the red led lights up during any of these procedures restart the programming mode from the beginning INSTALLATION DIAG RAMS nterface mode for Porter s exchange To the next floor T 7720 T 7720 BUS HZHZ BUS HZHZ FA PLUS C CE 941 Plus ver 938072 PRI SEC T 7720 T 7720 230110 0 A BUS HHZHZ BUS JHZHZ FA PLUS C ver 938072 CD 2PLUS A PRI SEC DJA 230 110 o Main 2PLUS Door Panel FA PLUS C ver 938072 PRI SEC 230 110 O Main IMPORTANT For the configuration and programming of each equipment see the corresponding manual 32 IN STALLATIO N DIAGRAMS R atone encoder mode coded
17. acas generales Placa codificada Plus Ala siguiente planta Edificio 1 Ce Placa 2PLUS STADIO FA PLUS C 0000 O 100 O rev 938072 0006 O PRI 230 110 O Red FA PLUS C rev 938072 FA PLUS C rev 938072 Z gt Placa General Plus P R de comunicaciones ACTIVADA IMPORTANTE Para la configuraci n y programaci n de cada equipo ver el manual de producto correspondiente 10 Ala siguiente planta Edificio 250 Placa 2PLUS FA PLUS C rev 938072 PRI 230 110 O Red FA PLUS C rev 938072 O Principal Secundario FA PLUS C rev 938072 Z gt Placa General Plus S R de comunicaciones DESACTIVADA PRI SEC cy cv AJA VV VTV E m P out in in lint outy out Red A la s siguiente s placa s SOLUCI N DE AVER AS 11 Modo interface de central de conserjer a La central no recibe llamadas de la placa amp Compruebe si puede recibir
18. and programming of each equipment see the corresponding manual 34 To the next floor Building 250 2PLUS Door Panel FA PLUS C rev 938072 FA PLUS C rev 938072 Master O Slave FA PLUS C rev 938072 e gt General door panel Plus Communications Resistor DISABLED cy cv AJA VV VTV iG m 0 out in in line Jour out To the next door panel s TRO UBLESHO OTING HINTS 35 Interface mode for porter s exchange c The porter s exchange doesn treceive calls from the door panel amp Check if calls are received from any other telephone pressing the lock release push button with the handset off the hook lt Ifso check the porter s exchange configuration verify the option of seizing the panel is active and thatthe switch number 3 issetto O N amp If not check the porter s exchange is not switch off the screen shows a line of points remember the red led is always lighted lt Check the wiring page 31 and the converter configuration page 29 Backbone encoder mode General entrance door panels c Impossible to call from the general entrance door panels amp Check whether itis possible to call from the internal panels
19. au du d but SCHEMAS IN STALLATIO N 19 M ode interface centrale conciergerie Dans l tage suivant T 7720 T 7720 BUS HZHZ BUS HZHZ FA PLUS C CE 941 Plus ver 938072 PRI SEC T 7720 T 7720 230 110 O A Reseau BUS HZHZ BUS HZHZ FA PLUS C ver 938072 CD 2PLUS H PRI SEC Bus D A 230110 o Reseau P Principale S secondaire Plaque 2PLUS FA PLUS C ver 938072 PRI SEC 230 110 0 IN Reseau IMPORTANT Pour la configuration et programmation de chaque quipe voir le manuel de produit correspondant 20 SCHEMAS INSTALLATION M ode codificateur de colonnes montantes plaque codifi e Dans l tage suivant gt Plaque Codifi e Plus T 7720 HZ HZ STADIO Plaque 2PLUS SS FA PLUS C ver 938072 PRI 0000 INOX 230 110 0 90009 99090 000 Reseau
20. ing from previous page Backbone encoder General entrance door panels Itis possible to install a general entrance door panel Plus with inner portals 2PLUS so thata porter s exchange CE 941 Plus can be inserted optionally between both elements A conversor per inner collumn is required Installation diagram on page 33 2PLUS telephones 2PLUS telephones Backbone 1 Backbone 2 2PLUS Door panel 2PLUS Door panel EC ao FA PLUS C oo Ss 2 Lock release Lock release CO ao FA PLUS C So 2 5 2 N y To the rest of the Backbones 3 FA PLUS C Porter s Exchange gt General entrance General entrance El E Y door panel Plus door panel Plus e Soo po m gt Backbone 0 SS _ FA PLUS C SS A FA PLUS C 2000 LD Lock release 2 EE 2 Lock relase 2 ES 2 Backbone encoder Coded panel This variable of the previous mode allows installing coded panels Plus with 2PLUS telephones by changing only the converter position so thatitis atthe end of the doorpanel Itis also possible to insert a porter s exchange before the converter or a 2PLUS door panel between the converter and the telephones Itcan be applied with or without general entrance door panels Installation diagram on page 32 2PLUS Telephones
21. lignotant Existe une interf rence dans l installation entre les fils du bus 18 PRO G RAM MATIO N DE LA COLONNE Prose mmation du convertisseur En cas d utiliser ce module comme codificateur de la colonne de montante plaques g n rales voir page 15 il faudra programmer un code de colonne montante diff rent pour chaque convertisseur Pour le faire suivre les pas suivants GOLMAR y Acc der au mode de programmation de la plaque 13 15 de rue en poussant sur la touche cle et le code secret d installateur valeur fabrique1315 comme le manuel de la plaque indique Activerla programmation du convertisseur en placantle micro interrupetur num ro 1 en position O N La plaque mettra des signaux sonneurs et le led vert du convertisseur clignotera lentement pour indiquer que la programmation estcommenc e Introduire le code de la colonne montante qui doit tre programm e suivi de trois z ros continuation pousser la touche cloche Pour indiquer que l quipe a t programm e correctement la plaque mettra des signauxs soneurs Sortir de programmation placer le micro interrupteur num ro 1 enO FF etpousserla touche Cancel de la plaque En cas d exister d autres convertisseurs repeter les pas anterieurs avec des codes de colonne de montant diff rents pour chacun d eux Si pendant un de ces pas un led rouge du convertisseur s allume la programmation doit tre commenc e nouve
22. mo alimentador El convertidor podr a da arse Para evitar da os el convertidor tiene que estar firmemente anclado gt gt gt gt gt gt CARACTER STICAS DEL SISTEMA c Convertidor de protocolo para sistema 2PLUS que permite las siguientes combinaciones gt Permite instalar una central de conserjer a Plus en una instalaci n 2PLUS gt Permite instalar placas generales Plus con accesos interiores en sistema 2PLUS gt Permite instalar una placa codificada Plus con tel fonos 2PLUS Hasta 250 convertidores por instalaci n Hasta 120 viviendas y 120 tel fonos por canal Sencilla configuraci n mediante microrruptores de f cil acceso Leds de autodiagn stico que permiten detectar errores de instalaci n y o de programaci n Necesario un alimentador FA Plus C dedicado exclusivamente para alimentar el convertidor EYE MO DOS DE FUNCIO NAMIENTO El convertidor CD 2PLUS dispone de 3 posibles modos de funcionamiento Interface de central Permite intercalar una central de conserjeria CE 941 Plus entre la placa y los tel fonos pudiendo realizar las funciones t picas de esta central Capturar llamadas desde Tel fonos 2PLUS placa recibir y realizar llamadas a las viviendas transferir llamadas de placa a viviendas guardar en memoria las llamadas no contestadas de las viviendas etc M ximo una placa por sistema Solo una placa env a la llamada a conserjer a Esquema de in
23. n cada convertidor siguiendo los pasos descritos a continuaci n GOLMAR Acceder al modo de programaci n de la placa 13 15 F pulsando la tecla Ilave seguida del c digo secreto de instalador valor de f brica 1315 tal y como se indica en el manual de la placa Activar la programaci n del convertidor colocando el microrruptor n mero 1 en ON La placa emitira unos tonos y el led verde del convertidor iniciar un parpadeo lento indicando que la programaci n se ha iniciado Introduzca el c digo de canal a programar seguido de tres ceros a continuaci n pulse la tecla campana Para indicar que el equipo se ha programado correctamente la placa emitir unos tonos Salga de programaci n colocando el microrruptor n mero 1 en OFF ypulsando la tecla Cancel de la placa En caso de existir m s convertidores repita los pasos anteriores introduciendo un c digo de canal diferente para cada uno de ellos Si durante alguno de estos procesos se encendiera el led rojo del convertidor vuelva a iniciar la programaci n desde el principio ESQUEMAS DE INSTALACI N M odo interface de central de conserjer a A la siguiente planta T 7720 T 7720 BUS HZHZ BUS JHZHZ FA PLUS C CE 941 Plus ver 938072 r FE CR 1 3 PRI SEC T 7720 T 7720 230 110 0
24. nd handling of this equipment must be performed by authorised personnel o Install or modify the equipment without the power connected c Do notuse excessive force when tightening the converter connection block screws o The entire installation mustbe atleast40 cm away from any other installation o Before connecting the system check the connections between door panel converter telephones and the power supply connection ce When starting the equipment for the firsttime or after a modification the system will remain inactive a few seconds due to the initial busy channel time c Necessarya dedicated FA Plus C power supplyto protocol converter module c Do notconnect the converter and the door panel with the same power supply The converter could be damaged c Do always follow the enclosed information N O SAFETY PRECAUTIONS nstall or modifythe equipmentwithoutthe power connected The installation and handling of these equipments mustbe performed by authorised personnel The entire installation mustbe atleast 40 cm away from any other installation Do notuse excessive force when tightening the connector screws nstall the unitin a dryand protected place withoutrisk of drip or water projections Avoid to place itnear to heating sources dusty locations or humid enviroments Do notblock ventilation holes of the unitso thatair can circulate freely Do not connect the converter and the door
25. ndaire pe 2 FA PLUS C Suite MODES DE FONCTIONNEMENT 15 Suite de la page pr c dente Codificateur de colonne montante Plaques de rue g n rales entre les deux l ments Permet installer des plaques g n rales a d filement de noms Plus avec des entr es int rieures 2PLUS en pouvant interceler de mani re optionnelle une centrale de conciergerie CE 941 Plus Ce type d installation pr cise d un convertisseur pour chaque colonne int rieure Voirsch ma d installation page 21 Poste 2PLUS Poste 2PLUS k Colonne montante 1 Centrale de conciergerie Plaque g n rale Plus a es Colonne montante 0 Plaque 2PLUS Plaque 2PLUS 8 8 G che G che ES FA PLUSIC Es omo omo ED omo 2 E 2 2 Colonne montante 2 FA FA PLUS C B 2 9 Au reste de colonnes montantes Plague g n rale Plus a e 3 2 FA PLUS C eee TD ses 2 gt A FA PLUS C XD G che 2 ones 2 G che 2 Codificateur de colonne montante Plaque codifi e Cette variable du mode anterieur permet d installer des plaques codifi s Plus avec des postes 2 PLUS seulement en changeant la position du convertisseur la sortie de la plaque De mani re optionnelle une centrale peut tre aussi intercal e avant le convertisseur ou une
26. ons vivement de suivre attentivementce manuel d instructions INDEX INTOdUCIOA Ateca tata teta ta tata Ad tooodo 13 Conseils pour la mise en marche Pr cautions de s curit a Caract ristiques du Semestre cido do nar ANA add tail Fonclionnement dusysteme is aaa sie pairando Lai abt pulo ai dona han pa opa nam e aa a Description A Install coca a ETE da EO PAGTO pa LEO belll pa DE Ra OS E aai 16 Configuration du micro interrupteur ss 17 Leds autodiagnostique ii iixess Programmation du colonne montante Sch mas d installation Mode interface centrale conciergerie ettaae rr nr rra narran Mode codificateur de colonne montante plaque codifi e 20 Mode codificateur de colonne montante plaques g n rales R solution des problemes diosas otra 23 NOS peo oca VER pan R Ga nid d DUE DA GR SAS GAS aR alada 36 38 COMPO Me io le ATAATA 39 CONSEILS PO UR LA MISE EN MARCHE o L installation etmanipulation de cette quipe doit tre r alis e par un personnel autoris o Lorsdel installation ou de interventions sur le syst me veiller couper l alimentation lectrique o Evitezde serrer de fa on excessive les vis de la r glette du convertisseur ce Toute l installation doit passer 40 cm au moins de toute autre installation ce Avant la mise sous tension v rifier les connexions entre la pla
27. plaque 2PLUS entre le convertisseur etles postes d appel Cette variante peut tre appliqu avec ou sans plaques g n rales Voirsch ma d installation page 20 Centrale de conciergerie x Nomendature Colonne Montante Direction logique OR Principale O Secondaire Poste 2PLUS FA PLUS C Ja co 2rLus 2 Plaque codifi e Plus FA PLUS C P 16 DESCRIPTION D escription du convertisseur Languette liberatrice du rail DIN Leds d auto diagnostic Micro interrupteur de configuration R glette de connection INSTALLATIO N D tails de l installation du convertisseur Installer l unit dans un endroit sec et prot g sans risque de d gouttement ou des projections d eau Pour viter des dommages le convertisseur a tre fermement fix e Lors de l installation ou de interventions sur le syst me veiller 93 5 x45 couper l alimentation lectrique DIN 7971 L installation et manipulation de cette quipe doit tre r alis e par un personnel autoris Pour installer le convertisseur sur un mur r aliser deux trous de 6mm de diam tre etintroduire les chevilles Soutenir le convertisseur avec les deux vis sp cifi es 03 5 x 45 Po DIN 7971 ME ES l Le convertisseur peut tre install sur le guide DIN 6 l ments par une l g re pression Pour retirer le convertisseur
28. que le convertisseur les postes d appel etlalimentation o Lorsque le syst me est mis en marche pour la premi re fois ou apr s une intervention le syst me sera inactif durant quelques secondes pour le temps de canal occup initial o N cessaire un alimentation FA Plus C d di exclusivement pour le convertisseur c Ne connectez pas le convertisseur et la plaque avec le m me alimentation Le convertisseur peut tre endommag ce Suiveza chaque instantles instructions de ce manual E 5 PR CAUTIO NS DE S CURIT Linstallationet manipulation de cette guipe doit tre r alis e par un personnel autoris Lors de l installation ou de interventionssur le syst me veillera couper l alimentation lectrique Evitez de serrer de fa on excessive les vis de la r glette Toute l installation doit passer 40 cm au moins de toute autre installation nstaller le convertisseur dansun endroitsec et prot g sans risque de d gouttementou projections d eau viter les emplacementstrop proche d une source de chaleur d humidit ou poussi reux Ne bloquezpaslesrainures d a ration de l appareil pour que l air puisse librementcirculer Ne connectez pas le convertisseur et la plaque avec le m me alimentation Le convertisseur peut tre endommag ce pour viter des dommages le convertisseur tre fermementfix e ETS EVE CARACTERISTIQ UES DU SYST ME ce Convertis
29. robar que los bornes BUS no est n cortocircuitados entre si ni con ning n otro borne Modo codificador de canal Placa codificada No se pueden realizar llamadas amp Recuerde que tras conectar la alimentaci n el equipo permanece inactivo durante unos 45 seg lo mismo ocurre al conectar cualquier unidad en la instalaci n amp Asegurese de que el convertidor no tiene ning n canal programado para ello ponga el microinterruptor n mero 2 en OFF seguidamente vuelva a colocarlo de nuevo en su posici n correcta O N esto resetea la programaci n del canal Revise el conexionado del convertidor p g 8 ysu configuraci n p g 5 amp Compruebe tambi n que la tensi n entre los bornes y de los diferentes elementos es de17 5a18 5Vc c sino esas compruebe el alimentador ysu conexionado C d 50124604 Convertisseur de protocole CD 2PLUS ao A el d installation TCD 2PLUSML rev 0112 INTRO DUCTION 13 Nous tenons tout d abord vous remercier et a vous f liciter pour l acquisition de ce produit fabriqu par Golmar La technologie avanc e des composants qui constitue ce produit ainsi que notre certification ISO 9001 assurent aux Clients et utilisateurs un haut niveau de prestations et une satisfaction totale dans le fonctionnementde ce portier audio ou vid o Afin de b n ficier d s sa mise en route de toutes les fonctionnalit s de ce produit nous vous recommand
30. seur du protocole pour le syst me 2PLUS qui permetles combinaisons suivantes gt Permetinstaller une centrale de conciergerie Plus pour une installation 2PLUS gt Permetinstaller des plaques de rue g n rales Plus avec des acc s int rieurs d un syst me 2PLUS gt Permetinstaller une plaque codifi Plus pour des postes 2PLUS ce Jusqu 250 convertisseurs par installation ce Jusqu 120 habitationset120 postes d appel par colonne montante ce Configuration simple travers des micro interrupteurs de facile acc s ce Leds d autodiagnostic qui permettent d tecter des erreurs d installation et ou programmation ce N cessaire un alimentation FA Plus C d di exclusivement pour le convertisseur MO DES DE FONCTIONNEMENT Le convertisseur CD 2PLUS dispose de 3 possibles modes de fonctionnement Interface de centrale Permet intercaler une centrale de conciergerie CE 941 Plus entre la plaque de rue et les postes d appel en pouvant r aliser les fonctions typiques de cette centrale Postes 2PLUS capturer des appels des la plaque recevoir et r aliser des appels aux habitages transf rer des appels d s la plaque aux habitages garder dans la m moire les appels non r pondus etc Maximum une plaque de rue par syst me Seulement une plaque envoie l appel a la centrale de conciergerie Sch ma d installation la page 19 CE 941 Plus ale O Principale G che Seco
31. sicen estpasle cas v rifier l alimentation etla connexion C d 50124604 Protocol converter CD 2PLUS INTRO DUCTION 25 First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar The commitment to reach the satisfaction of our customers is stated through the ISO 9001 Certification and for the manufacturing of products like this one Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers To obtain the maximum profit of these features and a properly wired installation we kindly recommend you to expend a few minutes of your time to read this manual INDEX Starting recommendations re Safety precauti NS sesasvaaassaaaisuasasaaasveaassaaasacaaivaaibvaaas cies System A seas O peration modes Description s o Installavons swine tins Configuration dip switch Autodiagnostic Leds o e Programming the converter Backbone code Installation dlagramS ss quen dei coto den pode ents tis lect tan Joe dose da dpt da EO ana SDL dati O RO Porter s exchange interface mode aia Backbone encoder mode coded panel Backbone encoder mode general door panel Troubleshooting hints NOTES as vis as i s t Compliance ai A oo atada pin sa da a O ad ne O RUA AP STARTING RECO MMENDATIO NS c The installation a
32. stalaci n en la p gina 7 CE 941 Plus CD 2PLUS a FAPLUSC Jo ing me Abrepuertas FA PLUS C E Principal gs 2 D Secundario j 2 2 Contin a MODOS DE FUNCIO NAMIENTO Viene de la pagina anterior Codificador de canal Placas generales Permite instalar placas generales Plus con portales interiores 2PLUS pudiendo intercalar opcionalmente una central de conserjeria CE 941 Plusentre ambos elementos Este tipo de instalaci n requiere un conversor por cada canal interior Esquema de instalaci n en la p gina 9 Tel fonos 2PLUS Tel fonos 2PLUS X Canal 1 Canal 2 Placa 2PLUS Abrepuertas Abrepuertas 2 FA PLUS C 2 2 mie Central de conserjer a ae Placa general Plus e Canal O 3 gt SA FA PLUS C ER Abrepuertas 2 TZ 2 Abrepuertas Codificador de canal Placa codificada Esta variable del modo anterior permite instalar placas codificadas Plus con tel fonos 2PLUS nicamente variando la posici n del conversor pasando a estara la salida de la placa Opcionalmente tambi n podemos intercalar una central de conserjer a antes del conversor o una placa 2PLUS entre el conversor ylos tel fonos Podemosaplicar esta variante con o sin placas generales Esquema de instalaci n en la p gina 8 Cen
33. tral de conserjer a hal x T rminos Canal Direcci n l gica 8 Principal O Secundario Abrepuertas 2 Placa 2PLUS A FA PLUS C 2 Alresto de canales Placa general Plus E FA PLUS C sses 2 122 2 Tel fonos 2PLUS FA PLUS C QuaDO cocos 2 DESCRIPCI N D escripci n del conversor Leng eta liberadora del camil DIN Leds de autodiagn stico Micronuptor de configuraci n Regleta de conexi n INSTALACI N D etalle de la instalaci n del conversor Instale el convertidor en un lugar seco y protegido sin riesgo de goteo o proyecciones de agua Para evitar da os el convertidortiene que estarfirmemente anclado Cuando se instale o modifique el equipo hacerlo sin 93 5 x 45 alimentaci n DIN 7971 a a sz p La instalaci n y manipulaci n de este equipo debe ser realizada por personal autorizado Para instalar el convertidor en pared realizar dos agujeros de 6mm de di metro e introducir los tacos Sujetar el convertidor mediante los tornillos especificados 3 5 x 45 DIN 7971 El convertidor puede instalarse en gu a DIN 6 elementos realizando una leve presi n Para sacar el convertidor de la gu a utilizar un destornillador plano y hacer palanca tal ycomo muestra el dibujo CONFIGURACIO